Sie sind auf Seite 1von 119

Precision Power. Perfect Light.

CONSTANT CURRENT CONSTANT VOLTAGE A/ C LED


ELECTRONIC
LED DRIVERS
www.hatchlighting.com
B A L L A S T S , D R I V E R S , T R A N S F O R M E R S & L A M P S F O R A L L L I G H T I N G A P P L I C A T I O N S
LED Catalog Flyer 2011_Rev2.0.indd 1 11/7/11 4:35 PM
About Hatch LED Drivers
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Constant current, constant voltage and A/C driver models
Models available from 1 watt up to 100 watts
Compact and unique case sizes to ft a wide variety of LED fxtures
European universal (90-264 VAC), wide range universal (120-277 VAC) and
dedicated input voltage models
Fully UL compliant and RoHS compliant
Models available with wire leads, terminal blocks, E26 or GU24 mounting
Unique A/C driver models with full range dimming capabilities -
Exclusively available with Hatch
Custom driver design and engineering services available for unique LED
projects and fxtures
Advanced LED driver engineering program launched in 2011 to
develop next generation drivers using patented Hatch Technology
Two Unique Solutions For Solid State Lighting Design
D/C LED Drivers vs. A/C LED Drivers
Currently in the world of LED lighting there are two methods that can be used to drive an LED using either
direct current or alternating current. The majority of commercially available LEDs are D/C driven (constant
current or constant voltage). A/C driven systems, however, are growing in popularity due to several unique
advantages that they offer. Hatch currently offers drivers for both D/C and A/C applications. Below are
a few benefts and drawbacks of each system:
Certifcations Certifcations
Product Family Features
Product Family Features
Very small driver case sizes for high wattage LEDs
Lower per unit cost than D/C drivers
Lower system costs over D/C fxtures and greater
ease of use in retroft applications (i.e. MR16 LEDs)
Step-less, full range dimming with no minimum load
(Unique Hatch technology)
Can only run A/C LEDs
A/C LEDs are complex systems and currently do
not match the effcacies and lumen outputs of D/C
systems
Available in limited wattages and case styles
D/C LED Drivers A/C LED Drivers
Ability to drive most commercially available LEDs
D/C LEDs are at the cutting edge of LED
technology and posses the highest effcacies
and lumen outputs compared to A/C LEDs
Available in a wide range of wattages
Available in a wide range of case sizes
Large driver case sizes, even for low wattage
LEDs
Very limited and expensive options for dimming
High system cost relative to A/C LEDs
Benefts Benefts
Drawbacks Drawbacks
Since 1985 Hatch has been at the cutting edge of power supply design and technology.
Drawing on over three decades of engineering expertise, Hatch is proud to introduce
a full line of electronic LED drivers for D/C and A/C systems. At Hatch our engineering
team is fuent in the technical design of LED lighting systems and is always available to
aid our customers in selecting the right driver for any application.
Electrical data and product
specifications in this catalog are
subject to change without notice
LED Catalog Flyer 2011_Rev2.0.indd 2 11/7/11 4:35 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
LED Driver Product Family Guide
Constant Voltage Drivers
Constant Current Drivers
A/C Drivers
RL
W
60
009
003
12
LCA
LV
RS
UNI
12
M
UNI
LED
Driver Type
LCA - 350mA CC
LCB - 700mA CC
Example Part Number
Example Part Number
Example Part Number
Driver Type
LV - Constant
Voltage
Product
Series
RS - A/C
Transformer
Wattage
3W
4W
6W
8W
9W
Wattage
3W
6W
10W
20W
60W
Output
Voltage
12 Volts
*24 Volts

Case Style
**Blank - Rectangular
L - Flat Rectangular
Q - Mini Rectangular
RL - Round
S - Slim Linear
WJ - Rectangular Bottom Feed
E - Edison Screw Base
J - Round Bottom Feed
G - GU24 Base

Case Style
W - Rectangular
Wattage
15W
30W
60W
Input Voltage
UNI - 90-264VAC
UNV - 120-277VAC
120 - 120VAC
Input Voltage
UNI - 90-264VAC
120 - 120VAC
Lamp Type
LED - LED
**Blank - Halogen
Output
Voltage
12 Volts
24 Volts
Case
Material
M - Metal
12W
15W
18W
30W
85W
* 24 Volt output models currently in development. Contact Hatch for more information.
** Blank indicates that no letter or number appears in this slot in a part number.
Case style only indicates the general shape of the case. Actual dimensions vary by model. Please see
individual specifications on our website for exact dimensions.
A/C Driver Features
Based on RS-Series
Hatch transformers
Circuitry optimized for
LED loads
No minimum load, full
range dimming -
Industry Exclusive
Ideal for halogen track
MR16 LED retroftting
Approved for use with
most major A/C LEDs
Available in 120V &
230V input
The most advanced A/C
driver in the industry
CV Driver Features
Circuitry optimized for
constant voltage LEDs
Used to drive LEDs
wired in parallel
Unique case styles with
terminal blocks and
mounting feet
Lightweight, thermally
robust construction
Available in 12V and
24V output models
CC Driver Features
Circuitry optimized for
constant current LEDs
Used to drive LEDs
wired in series
Unique case styles with
terminal blocks or wire
leads with mounting feet
Lightweight, thermally
robust construction
Available in 350mA and
700mA models
TRIAC dimming available
with 9, 12 & 18W models
in E, J & G case styles
IDEAL FOR MR16 LED RETROFITTING
LED Catalog Flyer 2011_Rev2.0.indd 3 11/7/11 4:35 PM
A/C Drivers A/C Drivers
Constant Voltage Drivers Constant Voltage Drivers (Part numbers in orange are available in 12 & 24 volt output)
Constant Current Drivers Constant Current Drivers
LCA003-UNI 3 Watt 90-264 VAC 3-9 VDC 40mA@230 VAC 350mA Blank - Rectangular No
LCB003-UNI 3 Watt 90-264 VAC 4-5 VDC 40mA@230 VAC 700mA Blank - Rectangular No
LCA003-RL-UNI 3 Watt 90-264 VAC 3-9 VDC 40mA@230 VAC 350mA RL - Round No
LCA004-UNI 4 Watt 90-264 VAC 2-13.2 VDC 55mA@230 VAC 350mA Blank - Rectangular No
LCB004-UNI 4 Watt 90-264 VAC 4-7 VDC 55mA@230 VAC 700mA Blank - Rectangular No
LCB006-UNI 6 Watt 90-264 VAC 4-10 VDC 110mA@230 VAC 700mA Blank - Rectangular No
LCA006Q-UNI 6 Watt 90-264 VAC 2-19.8 VDC 65mA@230 VAC 350mA Q - Mini Rectangular No
LCB006-RL-UNI 6 Watt 90-264 VAC 3-13.4 VDC 110mA@230 VAC 700mA RL - Round No
LCA008-UNI 8 Watt 90-264 VAC 2-26.4 VDC 80mA@230 VAC 350mA Blank - Rectangular No
LCA009-RL-UNI 9 Watt 90-264 VAC 3-27 VDC 130mA@230 VAC 350mA RL - Round No
LCB009-RL-UNI 9 Watt 90-264 VAC 3-13.4 VDC 110mA@230 VAC 700mA RL - Round No
*LCA009-E-D-120 9 Watt 120 VAC 19-31 VDC 200mA@120 VAC 350mA *E, D & J - Round Yes - TRIAC
* LCB009-E-D-120 9 Watt 120 VAC 6-12 VDC 200mA@120 VAC 700mA *E, D & J - Round Yes - TRIAC
LCA012-L-UNI 12 Watt 90-264 VAC 3-36 VDC 70mA@230 VAC 350mA L - Flat Rectangular No
LCB012-L-UNI 12 Watt 90-264 VAC 4-18 VDC 70mA@230 VAC 700mA L - Flat Rectangular No
LCA012-S-UNI 12 Watt 90-264 VAC 3-36 VDC 70mA@230 VAC 350mA S - Slim Linear No
*LCA012-E-D-120 12 Watt 120 VAC 28-42.5 VDC 200mA@120 VAC 350mA *E, D & J - Round Yes - TRIAC
LCBDE015-L-UNI 15 Watt 90-264 VAC 2.5-16 VDC 75mA@230 VAC 700mA L - Flat Rectangular No
LCA018-UNI 18 Watt 90-264 VAC 2-59.5 VDC 100mA@230 VAC 350mA Blank - Rectangular No
LCB018-UNI 18 Watt 90-264 VAC 3-27 VDC 100mA@230 VAC 700mA Blank - Rectangular No
LCAP018-RL-UNV 18 Watt 120-277 VAC 3-54 VDC 200mA@120 VAC 350mA RL - Round No
LCBP018-RL-UNV 18 Watt 120-277 VAC 4-27 VDC 200mA@120 VAC 700mA RL - Round No
LCAP018-WJ-UNV 18 Watt 90-300 VAC 3-54 VDC 200mA@120 VAC 350mA
WJ - Rectangular
Bottom Feed
No
LCBP018-WJ-UNV 18 Watt 90-300 VAC 3-27 VDC 200mA@120 VAC 700mA
WJ - Rectangular
Bottom Feed
No
LCA018-S-UNI 18 Watt 90-264 VAC 3-54 VDC 100mA@230 VAC 350mA S - Slim Linear No
*LCA018-E-D-120 18 Watt 120 VAC 38-50 VDC 200mA@120 VAC 350mA *E, D & J - Round Yes - TRIAC
*LCB018-E-D-120 18 Watt 120 VAC 10-24 VDC 200mA@120 VAC 700mA *E, D & J - Round Yes - TRIAC
LCBDE030-UNI 30 Watt 90-264 VAC 45-55 VDC 300mA@100 VAC 700mA Blank - Rectangular Yes - 0-10VDC
LCBDE085-UNI 85 Watt 90-264 VAC 48-60 VDC 860mA@100 VAC 700mA Blank - Rectangular Yes - 0-10VDC
RS12-15M-LED 15 Watts 120 VAC 12 VAC 130mA 1300mA 2.20L x 1.23W x .75H Yes
RS12-15M-230-LED 15 Watts 230 VAC 12 VAC 70mA 1300mA 2.20L x 1.23W x .75H *No
RS12-30M-LED 30 Watts 120 VAC 12 VAC 250mA 2600mA 2.20L x 1.23W x .75H Yes
RS12-30M-230-LED 30 Watts 230 VAC 12 VAC 130mA 2600mA 2.20L x 1.23W x .75H *No
RS12-60M-LED 60 Watts 120 VAC 12 VAC 500mA 5200mA 2.20L x 1.23W x .75H Yes
RS12-60M-230-LED 60 Watts 230 VAC 12 VAC 260mA 5200mA 2.20L x 1.23W x .75H *No
RS12-60BF-LED 60 Watts 120 VAC 12 VAC 500mA 5200mA 2.72L x 1.30W x .80H Yes
RS12-60BF-230-LED 60 Watts 230 VAC 12 VAC 260mA 5200mA 2.72L x 1.30W x .80H *No
LV003W-12-UNI 3 Watt 90-264 VAC 12 or 24 VDC 40mA@230 VAC 250mA W - Rectangular No
LV006W-12-UNI 6 Watt 90-264 VAC 12 or 24 VDC 65mA@230 VAC 500mA W - Rectangular No
LV010W-12-UNI 10 Watt 90-264 VAC 12 or 24 VDC 100mA@230 VAC 40-833mA W - Rectangular No
LV012W-12-UNI 12 Watt 90-264 VAC 12 or 24 VDC 110mA@230 VAC 80-1000mA W - Rectangular No
LV012W-12-230 12 Watt 230 VAC 12 or 24 VDC 110mA@230 VAC 1000mA W - Rectangular No
LV020W-12-UNI 20 Watt 100-240 VAC 12 VDC 110mA@230 VAC 166mA W - Rectangular No
LV020W-12-F-UNI 20 Watt 90-264 VAC 12 or 24 VDC 235mA@230 VAC 166mA W - Rectangular No
LV020W-12-L-UNI 20 Watt 90-264 VAC 12 VDC 110mA@230 VAC 166mA W - Rectangular No
LV060W-12-120 60 Watt 120 VAC 24 VDC 650mA 250mA W - Rectangular No
LV100W-12-120 100 Watt 120 VAC 12 or 24 VDC 300mA 250mA W - Rectangular No
Basic Driver Specifications
Part Number Wattage Input Volts Output Volts Input Current Output Current

Case Style Dimmable


Part Number Wattage Input Volts **Output Volts Input Current Output Current Case Dimensions *Dimmable
Part Number Wattage Input Volts Output Volts Input Current Output Current

Case Style Dimmable


* This model is available with E-Edison screw base, G-GU24 base or J-Wire leads with mounting feet.
Case style only indicates the general shape of the case. Actual dimensions vary by model. Please see individual specifications on our website for exact dimensions.
Case style only indicates the general shape of the case. Actual dimensions vary by model. Please see individual specifications on our website for exact dimensions.
* Full dimming capabilities are currently only available in 120 volt input models. Hatch is currently developing full range dimming for all input voltages. Please contact
Hatch for the latest updates on LED driver development.
** 24 Volt output models currently in development. Contact Hatch for more information.
For full product specifications please visit our website at www.HatchLighting.com
H
A
T
C
H

O
F
F
E
R
S

C
U
S
T
O
M

L
E
D

D
R
I
V
E
R

S
O
L
U
T
I
O
N
S

F
O
R

U
N
I
Q
U
E

P
R
O
J
E
C
T
S

A
N
D

F
I
X
T
U
R
E
S

REV: 2.0 111027
LED Catalog Flyer 2011_Rev2.0.indd 4 11/7/11 4:35 PM
ELECTRONIC
HID BALLASTS
B A L L A S T S , D R I V E R S , T R A N S F O R M E R S & L A M P S F O R A L L L I G H T I N G A P P L I C A T I O N S
Precision Power. Perfect Light.
Electronic HID Catalog 2011_Rev2.1.indd 1 11/8/11 3:25 PM
Electronic HID Ballasts
Hatch Electronic HID ballasts
have been designed from the
ground up to be the most
reliable and fexible ballasts
in the lighting industry.
Available in a wide variety of
case sizes and confgurations,
Hatch HID ballasts are
recognized in the lighting
industry for their proven
dependability in countless
applications. With millions of
units performing in the feld
today, Hatch HID ballasts can
be trusted to deliver superior
light and lamp life.
Superior color uniformity
Low profle, lightweight cases
Excellent lumen maintenance
Constant lumen output over a
wide input voltage range and
lamp voltage variation
Signifcant energy savings when
compared to magnetic ballasts
Integrated thermal protection
Approval for recessed use
Microprocessor control
Safety Shutdown features
End of lamp life protection
Superior hot lamp restrike
characteristics
Designed, tested, & approved for
most lamp brands
Low voltage lamp shutdown
All Hatch Electronic HID Ballasts Feature:
w
w
w
.
h
a
t
c
h
l
i
g
h
t
i
n
g
.
c
o
m
1
Electronic HID Catalog 2011_Rev2.1.indd 2 11/8/11 3:25 PM
Table of Contents
Intro: Electronic HID Ballasts
To view complete online HID
ballast specifcations, scan this
barcode with your Smartphone.
1
Table of Contents
2
Part Number Guide
4
Technological Innovations in HID
3
Part Numbers & Specifcations
Pico 7
Pico2 8
Nano 9-10
Micro Slim 11-12
Slim 13-14
Mini 15-16
Standard 17-18
7
-
1
8
Case Styles
5
-
6
Wire Diagrams
1
9
-
2
0
Remote Mounting Information
2
1
Products By Hatch
2
2
2 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 2
Dont have a scanning App? Search the Apple App Store,
Android Market or BlackBerry App World for a barcode
scanning application
Electronic HID Catalog 2011_Rev2.1.indd 3 11/8/11 3:25 PM
T
e
c
h
n
o
l
o
g
i
c
a
l

I
n
n
o
v
a
t
i
o
n
s

I
n

H
I
D
Ultra Low Spectral Power Ratio
This is a measure of the ballasts fundamental frequency (desired frequency) power in
proportion to the unwanted frequency (high frequency) power. For operation with most
lamps, ANSI requires that the Spectral Power Ratio in any 1kHz band between 10kHz and
400kHz be less than 1.8% of the total lamp power. All Hatch ballasts meet or exceed this
requirement.
Patented Lamp Current Crest Factor Control
Hatch ballasts have a patented system for actively compensating for lamp conditions and
adjusting the lamp current drive waveform to control the lamp current crest factor under all
lamp operating conditions over lamp warm up and lamp life. This results in reduced electrode
erosion and increased lamp life.
Patented Half Bridge (HB) Technology
Hatch Half Bridge 70 Watt and 100 Watt ballast models use a patented design of half bridge
topology which allows Hatch to produce one of the most high performance low wattage
ballast systems available. This patented technology improves many aspects of product reli-
ability over competitive ballast designs.
Resonant Start Technology & Hybrid Pulsed Resonant Ignition System (HPRIS)
Hatch was amongst the very early adopters of resonant start technology for HID lamps.
Historically HID lamps were started using a pulse ignitor which used a 3-4kV pulse to start
the lamp. Hatch adopted resonant start technology so as to reduce inconsistencies in
starting performance, especially where the lamp is mounted some distance from the ballast.
With the patented Hatch Resonant Start Technology, it is possible to start and run a lamp some
distance from the ballast where pulse ignition systems would fail due to lamp wiring
capacitance. Hatchs patented Resonant Start Technology has been developed over the
years to further refne lamps starting characteristics and our most up to date Hybrid Pulsed
Resonant Ignition System (HPRIS) is the safest and best performing HID ignition system to
be found in the industry.
Certifcations
Certifcations
3
Electronic HID Catalog 2011_Rev2.1.indd 4 11/8/11 3:25 PM
T
e
c
h
n
o
l
o
g
i
c
a
l

I
n
n
o
v
a
t
i
o
n
s

I
n

H
I
D
Ultra Low Spectral Power Ratio
This is a measure of the ballasts fundamental frequency (desired frequency) power in
proportion to the unwanted frequency (high frequency) power. For operation with most
lamps, ANSI requires that the Spectral Power Ratio in any 1kHz band between 10kHz and
400kHz be less than 1.8% of the total lamp power. All Hatch ballasts meet or exceed this
requirement.
Patented Lamp Current Crest Factor Control
Hatch ballasts have a patented system for actively compensating for lamp conditions and
adjusting the lamp current drive waveform to control the lamp current crest factor under all
lamp operating conditions over lamp warm up and lamp life. This results in reduced electrode
erosion and increased lamp life.
Patented Half Bridge (HB) Technology
Hatch Half Bridge 70 Watt and 100 Watt ballast models use a patented design of half bridge
topology which allows Hatch to produce one of the most high performance low wattage
ballast systems available. This patented technology improves many aspects of product reli-
ability over competitive ballast designs.
Resonant Start Technology & Hybrid Pulsed Resonant Ignition System (HPRIS)
Hatch was amongst the very early adopters of resonant start technology for HID lamps.
Historically HID lamps were started using a pulse ignitor which used a 3-4kV pulse to start
the lamp. Hatch adopted resonant start technology so as to reduce inconsistencies in
starting performance, especially where the lamp is mounted some distance from the ballast.
With the patented Hatch Resonant Start Technology, it is possible to start and run a lamp some
distance from the ballast where pulse ignition systems would fail due to lamp wiring
capacitance. Hatchs patented Resonant Start Technology has been developed over the
years to further refne lamps starting characteristics and our most up to date Hybrid Pulsed
Resonant Ignition System (HPRIS) is the safest and best performing HID ignition system to
be found in the industry.
Certifcations
Certifcations
3
Electronic HID Catalog 2011_Rev2.1.indd 4 11/8/11 3:25 PM
Understanding Hatch HID Ballast Part Numbers
Example Part Number: MC39-1-F-UNNU
4 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Part Number Guide
C
a
s
e

S
t
y
l
e
s
U

-

M
in
i
o
r

S
t
a
n
d
a
r
d
S

-

S
lim

o
r

M
ic
r
o

S
lim

-



L
e
a
d
s

O
u
t

O
p
p
o
s
it
e

S
id
e
s
S
L
-

S
lim

o
r

M
ic
r
o

S
lim

-



L
e
a
d
s

O
u
t

O
n
e

S
id
e

X

-

N
a
n
o

S
lim
Y

-

P
ic
o

2

S
lim
Z

-

P
ic
o

S
lim
MC 39 1 F UNN U
H
I
D

B
a
l
l
a
s
t

T
y
p
e
M
C

-

C
e
r
a
m
ic

M
e
t
a
l
H
a
lid
e
M
S

-

H
ig
h

P
r
e
s
s
u
r
e

S
o
d
iu
m
L
a
m
p

W
a
t
t
a
g
e
2
0

-


2
0

W
a
t
t
s
2
2


-


2
2

W
a
t
t
s
3
9


-


3
9

W
a
t
t
s
5
0


-


5
0

W
a
t
t
s
7
0


-


7
0

W
a
t
t
s
1
0
0

-


1
0
0

W
a
t
t
s
1
5
0

-


1
5
0

W
a
t
t
s
N
u
m
b
e
r

o
f

L
a
m
p
s
1

-

1

L
a
m
p
2

-

2

L
a
m
p
I
n
p
u
t

V
o
l
t
a
g
e
1
2
0

-

1
2
0

V
o
lt
s
2
7
7

-

2
7
7

V
o
lt
s
1
2

-

1
2
0

V
o
lt
s
2
7

-

2
7
7

V
o
lt
s
U
N
N

-

U
n
iv
e
r
s
a
l
V
o
lt
a
g
e



(
1
0
8
-
3
0
5

V
o
lt
s
)
U
N
L

-

L
o
w

I
g
n
it
io
n



V
o
lt
a
g
e
Part Numbers for AC & DC Models
Example Part Number: MC39-1-F-24ACU
24
ACU
O
u
t
p
u
t
1
2
-
1
2
V
o
lts
2
4
-
2
4
V
o
lts
In
p
u
t
C
u
r
r
e
n
t
T
y
p
e
A
C
U
-
A
C
In
p
u
t
D
C
U
-
D
C
In
p
u
t
M
o
u
n
t
i
n
g
F

-

W
it
h

F
e
e
t
J

-

B
o
t
t
o
m

F
e
e
d

w
it
h

S
t
u
d
s
T

-

T
r
a
c
k

M
o
u
n
t

w
/
o

F
e
e
t
N

-

N
o

C
a
s
e
-

C
u
s
t
o
m

O
r
d
e
r

O
n
ly
MC39-1-F-
Electronic HID Catalog 2011_Rev2.1.indd 5 11/8/11 3:25 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 5
Case Styles
Pico
Wattage Voltage
20 Watt 120V Dedicated
Pico2
Wattage Voltage
20 Watt Universal
39 Watt 120V Dedicated
Nano
Wattages Voltages
20 Watt
120V or 277V
Dedicated
22 Watt
39 Watt
Micro Slim
Wattages Voltages
20 Watt
Universal 39 Watt
70 Watt
Hatch offers the largest selection of electronic HID
case styles and configurations in the lighting industry.
Since 1999, Hatch has pioneered the miniaturization
of E-HID technology and has set several industry
design standards for new, smaller E-HID fixtures.
Hatch is proud to introduce the new Pico and Pico2
case styles which represent the pinnacle of low
wattage E-HID design efficiency and technology.
VANCOUVER INTERNATIONAL AIRPORT - VANCOUVER, BC
Architectural Fixtures Powered by
MC39-1-F-UNNU & MC150-1-F-120U Ballasts
NEW
NEW
TRAILBLAZING BALLAST TECHNOLOGY
IN SEVEN UNIQUE CASE STYLES
*Each case style listed in the Size Chart represents a side lead model with no
mounting feet. All HATCH E-HID Ballasts are available in several mounting and wiring
configurations, each with slightly different dimensions from those listed in the chart.
Please see each ballast specification for exact configuration dimensions.
Electronic HID Catalog 2011_Rev2.1.indd 6 11/8/11 3:25 PM
Standard
Wattages Voltages
70 Watt Universal
100 Watt
120V or 277V
Dedicated &
Universal
150 Watt
120V or 277V
Dedicated
Mini
Wattages Voltages
20 Watt
120V or 277V
Dedicated &
Universal
22 Watt
39 Watt
50 Watt
Universal
70 Watt
Slim
Wattages Voltages
70 Watt
Universal
100 Watt
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Case Styles
P
i
c
o
1.30" 1.33" 1.77" 1.70" 2.96" 3.62" 1.74"
2
.
9
9
"
3
.
5
8
"
3
.
8
6
"4
.
7
0
"
3
.
2
6
"
4
.
8
0
"
7
.
2
0
"
P
i
c
o
2
N
a
n
o
M
i
c
r
o

S
l
i
m
S
l
i
m
M
i
n
i
S
t
a
n
d
a
r
d
HID STREET LIGHTS - NEW YORK CITY, NEW YORK
Over 300,000 Street Lights Powered by
MS100-1-F-120U & MC150-1-F-120U Ballasts
Available for CMH or HPS Lamps Also available in AC & DC input models
CASE STYLE
SIZE CHART
*
6
Electronic HID Catalog 2011_Rev2.1.indd 7 11/8/11 3:26 PM
Z - Pico Slim F - With Feet
Z - Pico Slim T- Track mount w/o feet
MOUNTING
MOUNTING
CASE STYLE
CASE STYLE
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 7
PICO
Case Material: Polycarbonate
Watts
Hatch
Part
Number
Description
Lamp Types/
ANSI Codes
Voltage
Nominal
Input
Power
Input
Current/
Input Voltage
Wire
Diagram
20
MC20-1-F-120Z 20 Watt 120V Pico w/Feet
M/C156 Ceramic MH
Dedicated
120V
24 Watts .20 Amps @ 120V I, VI
MC20-1-T-120Z 20 Watt 120V Pico w/o Feet
Case Dimensions and Mechanical Specifications
Wiring Information
Lead Length : Input/Output : 6.5
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 10 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
Wiring Information
Lead Length : Input/Output : 6.5
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 10 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
Part Numbers & Electrical Specifications
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33
1.30
1.10
2.99"
P
i
c
o
P
i
c
o
2
N
a
n
o
S
l
i
m
M
i
n
i
S
t
a
n
d
a
r
d
3.75
1.30
1.10
2.99"
3.56"
M
i
c
r
o

S
l
i
m
Part Numbers & Specifications All measurements in inches
Electronic HID Catalog 2011_Rev2.1.indd 8 11/8/11 3:26 PM
Part Numbers & Specifications
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 8
3
.5
8

1.33
1.16
3
.5
8
1.33
1.30
2
.375 height
8/32 thread
All measurements in inches
Y - Pico 2 Slim F - Side leads with feet
Y - Pico 2 Slim T- Track mount w/o feet
Y - Pico 2 Slim J - Bottom feed with studs
MOUNTING
MOUNTING
MOUNTING
CASE STYLE
CASE STYLE
CASE STYLE
Wiring Information
Lead Length : Input/Output : 6.5
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 10 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
Wiring Information
Lead Length : Input/Output : 6.5
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 10 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
Wiring Information
Lead Length : Input/Output : 6.5
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 10 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
Watts
Hatch
Part Number
Description
Lamp Types/
ANSI Codes
Voltage
Nominal
Input Power
Input Current/
Input Voltage
Wire
Diagram
20
MC20-1-T-UNNY 20 Watt Universal Pico 2 w/o Feet
M/C156 Ceramic
MH
Universal
120V
to
277V
24 Watts
.20 Amps @ 120V
.12 Amps @ 208V
.10 Amps @ 240V
.09 Amps @ 277V
I, VI MC20-1-F-UNNY 20 Watt Universal Pico 2 With Feet
MC20-1-J-UNNY 20 Watt Universal Pico 2 Bottom Feed
39
MC39-1-T-120Y 39 Watt 120V Pico 2 Track
M/C156 Ceramic
MH
Dedicated
120V
or
277V
44 Watts
.37 Amps @ 120V
.22 Amps @ 208V
.19 Amps @ 240V
.16 Amps @ 277V
I, VI MC39-1-F-120Y 39 Watt 120V Pico 2 With Feet
MC39-1-J-120Y 39 Watt 120V Pico 2 Bottom Feed
PICO2
Case Material: Metal
Case Dimensions & Mechanical Specifications
Part Numbers & Electrical Specifications
P
i
c
o
P
i
c
o
2
N
a
n
o
S
l
i
m
M
i
n
i
S
t
a
n
d
a
r
d
3
.5
8

3
.1
3

1.33
1.16
4
.1
3

M
i
c
r
o

S
l
i
m
Electronic HID Catalog 2011_Rev2.1.indd 9 11/8/11 3:26 PM
Part Numbers & Specifications
9 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
All measurements in inches
NANO
Case Material: Metal
1
.7
1

3
.7
9

1.12
.5 height
8/32 thread
X - Nano Slim F - Side lead with feet
X - Nano Slim J - Bottom feed with studs
MOUNTING
MOUNTING
CASE STYLE
CASE STYLE
Watts
Hatch
Part Number
Description
Lamp Types/
ANSI Codes
Voltage
Nominal
Input
Power
Input Current/
Input Voltage
Wire
Diagram
20
MC20-1-F-120X 20 Watt 120V Nano w/Feet
M/C156 Ceramic MH
Dedicated
120V
or
277V
24 Watts
.20 Amps @ 120V
.12 Amps @ 208V
.10 Amps @ 240V
.09 Amps @ 277V
II, IV
MC20-1-F-277X 20 Watt 277V Nano w/Feet
MC20-1-J-120X 20 Watt 120V Nano Bottom Feed
MC20-1-J-277X 20 Watt 277V Nano Bottom Feed
22
MC22-1-F-12LX 22 Watt 120V Nano w/Feet Low Strike
Phillips CDM-TM
20W/830* C175E
Dedicated
120V
or
277V
26 Watts
.22 Amps @ 120V
.13 Amps @ 208V
.11 Amps @ 240V
.10 Amps @ 277V
IV
MC22-1-F-27LX 22 Watt 277V Nano w/Feet Low Strike
MC22-1-J-12LX 22 Watt 120V Nano Bottom Feed Low Strike
MC22-1-J-27LX 22 Watt 277V Nano Bottom Feed Low Strike
* Call for manufacturers approval
* Available without feet, special order
Case Dimensions & Mechanical Specifications
Part Numbers & Electrical Specifications
Wiring Information
Lead Length : Input/Output : 8
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
Wiring Information
Lead Length : Input/Output : 10
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
P
i
c
o
P
i
c
o
2
N
a
n
o
S
l
i
m
M
i
n
i
S
t
a
n
d
a
r
d
1.18
3
.8
6

4
.5
7

4
.3
8

1
.7
7

M
i
c
r
o

S
l
i
m
Electronic HID Catalog 2011_Rev2.1.indd 10 11/8/11 3:26 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Watts
Hatch
Part
Number
Description
Lamp Types/
ANSI Codes
Voltage
Nominal
Input
Power
Input Current/
Input Voltage
Wire
Diagram
39
MC39-1-F-12LX
39 Watt 120V Nano w/Feet
Low Strike
Phillips CDM-TM
35W/830* C179E
Dedicated
120V
or
277V
44 Watts
.37 Amps @ 120V
.22 Amps @ 208V
.19 Amps @ 240V
.16 Amps @ 277V
II, IV
MC39-1-F-27LX
39 Watt 277V Nano w/Feet
Low Strike
MC39-1-J-12LX
39 Watt 120V Nano Bottom Feed Low
Strike
MC39-1-J-27LX
39 Watt 277V Nano Bottom Feed Low
Strike
39
MC39-1-F-120X 39 Watt 120V Nano w/Feet
M130 Ceramic
MH
Dedicated
120V
or
277V
44 Watts II, IV
MC39-1-F-277X 39 Watt 277V Nano w/Feet
MC39-1-J-120X 39 Watt 120V Nano Bottom Feed
MC39-1-J-277X 39 Watt 277V Nano Bottom Feed
* Call for manufacturers approval
10
Part Numbers & Specifications
All measurements in inches
Electronic HID Catalog 2011_Rev2.1.indd 11 11/8/11 3:26 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Watts
Hatch
Part
Number
Description
Lamp Types/
ANSI Codes
Voltage
Nominal
Input
Power
Input Current/
Input Voltage
Wire
Diagram
39
MC39-1-F-12LX
39 Watt 120V Nano w/Feet
Low Strike
Phillips CDM-TM
35W/830* C179E
Dedicated
120V
or
277V
44 Watts
.37 Amps @ 120V
.22 Amps @ 208V
.19 Amps @ 240V
.16 Amps @ 277V
II, IV
MC39-1-F-27LX
39 Watt 277V Nano w/Feet
Low Strike
MC39-1-J-12LX
39 Watt 120V Nano Bottom Feed Low
Strike
MC39-1-J-27LX
39 Watt 277V Nano Bottom Feed Low
Strike
39
MC39-1-F-120X 39 Watt 120V Nano w/Feet
M130 Ceramic
MH
Dedicated
120V
or
277V
44 Watts II, IV
MC39-1-F-277X 39 Watt 277V Nano w/Feet
MC39-1-J-120X 39 Watt 120V Nano Bottom Feed
MC39-1-J-277X 39 Watt 277V Nano Bottom Feed
* Call for manufacturers approval
10
Part Numbers & Specifications
All measurements in inches
Electronic HID Catalog 2011_Rev2.1.indd 11 11/8/11 3:26 PM
11 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
1.21
4
.7
0

1
.7
0

S - Mircro Slim:
Leads out opposite sides
T - Track mount
w/o feet
SL - Mircro Slim:
Leads out one side
F - With feet
MOUNTING
MOUNTING
CASE STYLE
CASE STYLE
MICRO SLIM
Case Material: Polycarbonate
S - Mircro Slim:
Leads out opposite sides
F - With feet
MOUNTING CASE STYLE
Case Dimensions & Mechanical Specifications
Wiring Information
Lead Length : Input : 10, Output : 8
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
Wiring Information
Lead Length : Input : 10, Output : 8
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
Wiring Information
Lead Length : Input/Output : 8
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
P
i
c
o
P
i
c
o
2
N
a
n
o
M
i
c
r
o

S
l
i
m
S
l
i
m
M
i
n
i
S
t
a
n
d
a
r
d
1.21
4
.7
0

5
.5
0

1
.7
0

5
.1
3
"
1.21
1
.7
0

5
.5
0

4
.7
0

5
.1
3
"
Part Numbers & Specifications All measurements in inches
Electronic HID Catalog 2011_Rev2.1.indd 12 11/8/11 3:26 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
1
.7
0

1.21
4
.7
0

SL - Mircro Slim:
Leads out one side
T - Track mount
w/o feet
MOUNTING CASE STYLE
Watts
Hatch
Part
Number
Description
Lamp Types/
ANSI Codes
Voltage
Nominal
Input
Power
Input Current/
Input Voltage
Wire
Diagram
20
MC20-1-F-UNNS
20 Watt Universal Micro Slim w/Feet and
Leads out Opposite Sides
M/C156 Ceramic MH
Dedicated
120V
or
277V
24 Watts
.20 Amps @ 120V
.12 Amps @ 208V
.10 Amps @ 240V
.09 Amps @ 277V
II, III, IV
MC20-1-T-UNNS
20 Watt Universal Micro Slim w/o Feet w/
Leads out Opposite Sides
MC20-1-F-UNNSL
20 Watt Universal Micro Slim w/Feet and
Leads out One Side
MC20-1-T-UNNSL
20 Watt Universal Micro Slim w/o Feet w/
Leads out One Side
39
MC39-1-F-UNNS
39 Watt Universal Micro Slim w/Feet and
Leads out Opposite Sides
M130 Ceramic MH
Universal
120V
to
277V
44 Watts
.37 Amps @ 120V
.22 Amps @ 208V
.19 Amps @ 240V
.16 Amps @ 277V
II ,III, IV
MC39-1-T-UNNS
39 Watt Universal Micro Slim Track w/Leads
out Opposite Sides
MC39-1-F-UNNSL
39 Watt Universal Micro Slim w/Feet and
Leads out One Side
MC39-1-T-UNNSL
39 Watt Universal Micro Slim Track w/Leads
out One Side
70
MC70-1-F-UNNS
70 Watt Universal Micro Slim w/Feet and
Leads out Opposite sides
M/C85, M/C98, M/
C39, M/C143 Ceramic
MH
Universal
120V
to
277V
78 Watts
.65 Amps @ 120V
.37 Amps @ 208V
.32 Amps @ 240V
.28 Amps @ 277V
III, IV
MC70-1-T-UNNS
70 Watt Universal Micro Slim Track w/Leads
out Opposite Sides
MC70-1-F-UNNSL
70 Watt Universal Micro Slim w/Feet and
Leads out One side
MC70-1-T-UNNSL
70 Watt Universal Micro Slim Track w/Leads
out One Side
Part Numbers & Electrical Specifications
Wiring Information
Lead Length : Input/Output : 8
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
12
Part Numbers & Specifications
All measurements in inches
Electronic HID Catalog 2011_Rev2.1.indd 13 11/8/11 3:26 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 13
7
.2

1.47
1
.7
4

7
.2

7
.7
4
0

1
.7
4

1.47
SL - Slim:
Leads out one side
F - With feet
MOUNTING CASE STYLE
S - Slim:
Leads out opposite sides
T - Track mount
w/o feet
MOUNTING CASE STYLE
Wiring Information
Lead Length : Input : 8, Output : 10
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
Wiring Information
Lead Length : Input/Output : 8
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
SLIM
Case Material: Metal
S - Slim:
Leads out opposite sides
F - With feet
MOUNTING CASE STYLE
Case Dimensions & Mechanical Specifications
Wiring Information
Lead Length : Input : 8, Output : 10
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
P
i
c
o
P
i
c
o
2
N
a
n
o
S
l
i
m
M
i
n
i
S
t
a
n
d
a
r
d
M
i
c
r
o

S
l
i
m
1.47
7
.2

7
.7
4
0

1
.7
4

7
.5
6
"
7
.5
6
"
Part Numbers & Specifications All measurements in inches
Electronic HID Catalog 2011_Rev2.1.indd 14 11/8/11 3:26 PM
14 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Watts
Hatch
Part Number
Description
Lamp
Types/ANSI
Codes
Voltage
Nominal
Input
Power
Input Current/
Input Voltage
Wire
Diagram
70
MC70-1-F-UNNSL-HB
70 Watt Universal Slim w/Feet and Leads
out One Side
M/C90, M/C140
Ceramic MH
Universal
120V
to
277V
78 Watts
.65 Amps @ 120V
.37 Amps @ 208V
.32 Amps @ 240V
.28 Amps @ 277V
II, IV
MC70-1-F-UNNS-HB
70 Watt Universal Slim w/Feet and Leads
out Opposite Sides
MC70-1-T-UNNSL-HB
70 Watt Universal Slim Track w/Leads out
One Side
MC70-1-T-UNNS-HB
70 Watt Universal Slim Track w/Leads out
Opposite Sides
MC70-1-J-UNNS-HB 70 Watt Universal Slim Bottom Feed
100
MC100-1-F-UNNSL-HB
100 Watt Universal Slim w/Feet and Leads
out One Side
M/C90, M/C140
Ceramic MH
Universal
120V
to
277V
110 Watts
.94 Amps @ 120V
.54 Amps @ 208V
.47 Amps @ 240V
.41 Amps @ 277V
II, IV
MC100-1-F-UNNS-HB
100 Watt Universal Slim w/Feet and Leads
out Opposite Sides
MC100-1-T-UNNSL-HB
100 Watt Universal Slim Track w/Leads
out One Side
MC100-1-T-UNNS-HB
100 Watt Universal Slim Track w/Leads
out Opposite Sides
MC100-1-J-UNNS-HB
100 Watt Universal Slim
Bottom Feed
7
.2

1.47
1
.7
4
SL - Slim:
Leads out one side
T - Track mount
w/o feet
S - Slim J - Bottom feed with studs
MOUNTING
MOUNTING
CASE STYLE
CASE STYLE
7
.2

1.47
1
.7
4

.375 height
8/32 thread
Wiring Information
Lead Length : Input/Output : 8
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
Wiring Information
Lead Length : Input/Output : 8
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
Part Numbers & Electrical Specifications
Part Numbers & Specifications
All measurements in inches
* HB indicates a new half bridge ballast topology for certain 70 watt and 100 watt models. This patented technology improves many aspects of product
reliability over competitive ballast designs.
Electronic HID Catalog 2011_Rev2.1.indd 15 11/8/11 3:26 PM
15 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
3
.1
3

3
.4
5

1
.2
7

4
.1
1

U - Mini B - Bottom feed with studs


U - Mini F - With feet
MOUNTING
MOUNTING
CASE STYLE
CASE STYLE
Case Style Specs
Lead Length : Input/Output : 8"
Wire Type : Input: 18AWG, 105C, 600V
Mechanical Specifications:
Min.Starting Temp. : -30C
Max. Case Temp. : 80C
Remote Mounting : 25 ft Max
*24V AC/DC models only
Wiring Information
Lead Length : Input/Output : 10
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
MINI
Case Material: Metal
U - Mini F - With feet
MOUNTING CASE STYLE
Case Dimensions & Mechanical Specifications
Wiring Information
Lead Length : Input/Output : 8"
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
P
i
c
o
P
i
c
o
2
N
a
n
o
M
i
c
r
o

S
l
i
m
S
l
i
m
M
i
n
i
S
t
a
n
d
a
r
d
2
.9
6

3
.2
6

1.21
4
.0
4

3
.7
5
"
3
.7
5
"
3
.1
3

3
.4
5

1.27
2

.375 height
8/32 thread
Part Numbers & Specifications All measurements in inches
Electronic HID Catalog 2011_Rev2.1.indd 16 11/8/11 3:26 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Watts
Hatch
Part Number
Description
Lamp Types/
ANSI Codes
Voltage
Nominal
Input
Power
Input Current/
Input Voltage
Wire
Diagram
20
MC20-1-N-120U
20 Watt 120V No Case
Custom Order Only
M/C156 Ceramic
MH
Dedicated
120V
or
277V
24 Watts
.20 Amps @ 120V
.12 Amps @ 208V
.10 Amps @ 240V
.09 Amps @ 277V
II, IV
MC20-1-F-UNNU 20 Watt Universal Mini w/Feet
M/C156 Ceramic
MH
Universal
120V
to
277V
24 Watts
.20 Amps @ 120V
.12 Amps @ 208V
.10 Amps @ 240V
.09 Amps @ 277V
II, IV
MC20-1-J-UNNU 20 Watt Universal Mini Bottom Feed
MC20-1-F-24DCU 20 Watt Mini w/24V DC Input
M/C156 Ceramic
MH
Dedicated
120V
24 Watts 24V DC-1.0 Amps III, IV
22
MC22-1-F-UNLU
22 Watt Universal Mini Low Strike
w/Feet Phillips CDM-TM
20W/830* C175E
Universal
120V
to
277V
26 Watts
.22 Amps @ 120V
.13 Amps @ 208V
.11 Amps @ 240V
.10 Amps @ 277V
IV
MC22-1-J-UNLU
22 Watt Universal Mini Low Strike
Bottom Feed
39
MC39-1-N-120U
39 Watt Mini 120V No Case
Custom Order Only
M130 Ceramic MH
Dedicated
120V
or
277V
44 Watts
.37 Amps @ 120V
.22 Amps @ 208V
.19 Amps @ 240V
.16 Amps @ 277V
II, III, IV
MC39-1-F-277U 39 Watt 277V Mini w/Feet
MC39-1-J-277U 39 Watt 277V Mini Bottom Feed
MC39-1-N-277U
39 Watt Mini 277V No Case
Custom Order Only
MC39-1-F-UNLU
39 Watt Universal Mini Low Strike
w/Feet Phillips CDM-TM
35W/830 C179E
Universal
120V
to
277V
44 Watts
.37 Amps @ 120V
.22 Amps @ 208V
.19 Amps @ 240V
.16 Amps @ 277V
II, IV
MC39-1-J-UNLU
39 Watt Universal Mini Low Strike
Bottom Feed
MC39-1-F-24ACU 39 Watt Mini w/24V A/C Input
M130 Ceramic MH
Universal
120V
to
277V
44 Watts 1.84 Amps @ 24V III, V
MC39-1-J-24ACU 39 Watt Mini w/24V A/C Input
MC39-1-F-24DCU
39 Watt Mini with 24V DC Input
Custom Order Only
M130 Ceramic MH
Universal
120V
to
277V
44 Watts 1.84 Amps @ 24V III, V
MC39-1-F-UNNU 39 Watt Universal Mini w/Feet
M130 Ceramic MH
Universal
120V
to
277V
44 Watts
.37 Amps @ 120V
.22 Amps @ 208V
.19 Amps @ 240V
.16 Amps @ 277V
II, IV
MC39-1-J-UNNU
39 Watt Universal Mini Bottom
Feed
50
MC50-1-F-UNNU 50 Watt Universal Mini w/Feet
M110, M148 Ceramic
MH
Universal
120V
to
277V
56 Watts
.41 Amps @ 120V
.27 Amps @ 208V
.24 Amps @ 240V
.21 Amps @ 277V
II, IV
MC50-1-J-UNNU 50 Watt Universal Mini Bottom Feed
70
MC70-1-F-UNNU 70 Watt Universal Mini w/Feet
M/C98, M/C139,
M/C143 Ceramic
MH
Universal
120V
to
277V
78 Watts
.65 Amps @ 120V
.37 Amps @ 208V
.32 Amps @ 240V
.28 Amps @ 277V
II, IV
MC70-1-J-UNNU
70 Watt Universal Mini Bottom
Feed

Part Numbers & Electrical Specifications
16
Part Numbers & Specifications
All measurements in inches
Electronic HID Catalog 2011_Rev2.1.indd 17 11/8/11 3:26 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 17
U - Standard F - With feet
MOUNTING CASE STYLE
Wiring Information
Lead Length : Input/Output : 8"
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
STANDARD
Case Material: Metal
Case Dimensions & Mechanical Specifications
U - Standard F - With feet
MOUNTING CASE STYLE
Wiring Information
Lead Length : Input/Output : 9"
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
150 Watt Models Only
100 Watt Models Only
U - Standard J - Bottom feed with studs
MOUNTING CASE STYLE
Wiring Information
Lead Length : Input/Output : 9"
Wire Type : Input: 18AWG, 105C, 600V
Remote Mounting : 25 ft Max
Operating Temperatures
Minimum Starting Temperature : -30C
Maximum Case Temperature : 80C
3
.6
2

4
.8
0

1.61
2

* NOTE: Height 1.61"


Height 1.61"
Height 1.35"
P
i
c
o
P
i
c
o
2
N
a
n
o
M
i
c
r
o

S
l
i
m
S
l
i
m
M
i
n
i
S
t
a
n
d
a
r
d
3
.6
2

4
.8
0

1.35
5
.5
2

5
.1
9
"
3
.6
2

4
.8
0

5
.5
2

1.61
5
.1
9
"
.375" height
8/32" thread
Part Numbers & Specifications All measurements in inches
Electronic HID Catalog 2011_Rev2.1.indd 18 11/8/11 3:26 PM
Watts
Hatch
Part Number
Description
Lamp Types/
ANSI Codes
Voltage
Nominal
Input
Power
Input Current/
Input Voltage
Wire
Diagram
70
MC70-1-F-UNNU-HB 70 Watt Universal Standard w/Feet
M/C98, M/C139,
M/C143 Ceramic
MH
Universal
120V
to
277V
78 Watts
.65 Amps @ 120V
.37 Amps @ 208V
.32 Amps @ 240V
.28 Amps @ 277V
II, IV
MC70-1-J-UNNU-HB
70 Watt Universal Standard
Bottom Feed
100
MC100-1-F-UNNU-HB
100 Watt Universal Standard
w/Feet
M/C90, M/C140
Ceramic MH
Universal
120V
to
277V
110 Watts
.92 Amps @ 120V
.53 Amps @ 208V
.46 Amps @ 240V
.40 Amps @ 277V
II, IV
MC100-1-J-UNNU-HB
100 Watt Universal Standard
Bottom Feed
MC100-1-F-120U 100 Watt 120V Standard w/Feet
M/C90, M/C140
Ceramic MH
Dedicated
120V
or
277V
110 Watts
.92 Amps @ 120V
.53 Amps @ 208V
.46 Amps @ 240V
.40 Amps @ 277V
I, IV
MC100-1-J-120U 100 Watt 120V Standard Bottom Feed
MC100-1-F-277U 100 Watt 277V Standard w/Feet
MC100-1-J-277U 100 Watt 277V Standard Bottom Feed
150
MC150-1-F-120U 150 Watt 120V Standard w/Feet
M102, M142
Ceramic MH
Dedicated
120V
or
277V
164 Watts
1.37 Amps @120V
.79 Amps @ 208V
.69 Amps @ 240V
.60 Amps @ 277V
II, IV
MC150-1-J-120U
150 Watt 120V Standard
Bottom Feed
MC150-1-F-277U 150 Watt 277V Standard w/Feet
MC150-1-J-277U
150 Watt 277V Standard
Bottom Feed
MC150-1-F-120P
150 Watt 120V Standard w/Feet
Potted Case
MC150-1-F-277P
150 Watt 277V Standard w/Feet
Potted Case
18 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Part Numbers & Electrical Specifications
Part Numbers & Specifications
All measurements in inches
* HB indicates a new half bridge ballast topology for certain 70 watt and 100 watt models. This patented technology improves many aspects of product
reliability over competitive ballast designs.
Electronic HID Catalog 2011_Rev2.1.indd 19 11/8/11 3:26 PM
BLACK
BALLAST
WHITE
BLUE
RED
BLACK
BALLAST
WHITE
GREEN
GROUND
BLUE
RED
BLACK
BALLAST
WHITE BLUE
RED
GREEN
GROUND
BLACK
RED
BLUE
WHITE
GREEN
GROUND
BALLAST
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 19
Wire Diagrams
Double Ended or Bi-Pin Lamps IV
PAR Lamps III
PAR Lamps II
PAR Lamps I
WIRE DIAGRAM
WIRE DIAGRAM
WIRE DIAGRAM
WIRE DIAGRAM
Electronic HID Catalog 2011_Rev2.1.indd 20 11/8/11 3:26 PM
BLACK
RED
BLUE
WHITE
GREEN
GROUND
BALLAST
BLACK
RED
BLUE
WHITE
BALLAST
20 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Wire Diagrams
20
Double Ended or Bi-Pin Lamps V
Double Ended or Bi-Pin Lamps VI
WIRE DIAGRAM
WIRE DIAGRAM
Electronic HID Catalog 2011_Rev2.1.indd 21 11/8/11 3:26 PM
Remote Mounting and Installation Requirements for
Electronic HID Ballasts
21 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
To achieve optimal performance with Hatch Transformers
Electronic HID Ballasts, remote installation guidelines listed must
be followed. Failure to follow the guidelines listed below can result in
unacceptable lamp performance and loss of warranty coverage for
remote installation.
Installation Guidelines:
The main power supply to the ballast should be run separately from the
lamp leads, and cables from other electrical systems should not run in
the same conduit as, or in close proximity to, the lamp leads.
Do not add additional lamp leads from other ballasts in the same
conduit.
Use metal conduit that is a minimum of in or 20mm in diameter.
Maximum recommended remote mounting distance is 25 feet from
the ballast to the socket. For distances greater than 25 feet, please
contact your Hatch representative for guidance.
Note: For all Pico and Pico 2 Slim models, maximum recommended
remote mounting distance is 10 feet.
The following wire types are approved for use as lead wire extensions:
UL 3321/AWM
UL3071/SEW-2 or SF-2
Use of any other mounting method or wire type could create safety
hazards, cause erratic performance, and/or cause permanent
damage to ballast components. This can lead to premature field
failures and void the ballast warranty. Please contact Hatch for
approval of other wire types and with any other question regarding
the remote mounting of Hatch Electronic HID Ballasts.
Electronic HID Catalog 2011_Rev2.1.indd 22 11/8/11 3:26 PM
22 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
About Hatch
Since 1985, Hatch has been the recognized market leader in
the design and manufacture of premium power lighting products
and solutions. Hatch offers a complete line of electronic and
magnetic ballasts and transformers for virtually all lighting
applications and is one of the largest independent, full-line power
supply manufacturers in the world.
To view a complete Hatch
Product Catalog, scan this
barcode with your Smartphone.
Current Hatch products include:
Electronic LED Drivers
Electronic HID Ballasts
Linear Fluorescent Ballasts
Compact Fluorescent Ballasts
Electronic Low Voltage Transformers
Remote Transformers
Magnetic HID Ballasts
Fluorescent Lamps
Sign Ballasts
Dont have a scanning App? Search the Apple App Store,
Android Market or BlackBerry App World for a barcode
scanning application
Electrical data and product
specifications in this catalog are
subject to change without notice
Electronic HID Catalog 2011_Rev2.1.indd 23 11/8/11 3:27 PM
Hatch Transformers, Inc.
Global Headquarters
7821 Woodland Center Blvd.
Tampa, FL 33614
P: 813.288.8006
F: 813.288.8105
www.hatchlighting.com
REV: 2.0 111027
B A L L A S T S , D R I V E R S , T R A N S F O R M E R S & L A M P S F O R A L L L I G H T I N G A P P L I C A T I O N S
Electronic HID Catalog 2011_Rev2.1.indd 24 11/8/11 3:27 PM
MAGNETIC
HID BALLASTS
Precision Power. Perfect Light.
B A L L A S T S , D R I V E R S , T R A N S F O R M E R S & L A M P S F O R A L L L I G H T I N G A P P L I C A T I O N S
Magnetic HID Catalog 2011_Rev2.0.indd 1 11/8/11 11:55 AM
Magnetic HID Ballasts
Hatch magnetic G-Series HID
ballasts provide unmatched
quality and reliability for lighting
applications. Available in all
popular lamp types, wattages
and voltages these products are
designed to meet the needs of
distributors, fxture manufacturers
as well as maintenance and repair
businesses. Hard to fnd & custom
confgurations are available. To
make installation easy all
ballasts are available in pre-wired
kits. Based on more than 10 years
of successful service in the feld
Hatchs magnetic HID ballasts can
be counted on to get the job done.
Smaller, lighter designs for
optimum performance in tight
spaces
State of the art vacuum pressure
impregnation for superior
performance and reliability
Tightly welded laminations
resulting in quiet operation, ideal
for applications where noise is a
concern
Color coded lead wires that
correspond to product labels
allowing easy, error-free
installation
Availability in quad tap and fve
tap confgurations for optimum
fexibility
Class N 200C insulation ratings
providing world class thermal
performance
Availability in pre wired kit forms
for easy installation
Easy to understand part
numbers for ease of selection
All Hatch Magnetic HID Ballasts Feature:
w
w
w
.
h
a
t
c
h
l
i
g
h
t
i
n
g
.
c
o
m
1
Magnetic HID Catalog 2011_Rev2.0.indd 2 11/8/11 11:55 AM
Table of Contents
Intro: Magnetic HID Ballasts
Table of Contents
Part Number Guide
About Hatch Magnetic HID
General Ballast Specifcations
Dimensional Diagrams
Replacement Kit Information &
Troubleshooting
About Hatch
1
2
4
3
6
-
8
5
9
1
0
2 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
To view complete online Magnetic
HID ballast specifcations, scan this
barcode with your Smartphone.
Dont have a scanning App? Search the Apple App Store,
Android Market or BlackBerry App World for a barcode
scanning application
Magnetic HID Catalog 2011_Rev2.0.indd 3 11/8/11 11:55 AM
A
b
o
u
t

H
a
t
c
h

M
a
g
n
e
t
i
c

H
I
D

B
a
l
l
a
s
t
s
3
Broad line: Over 350 UL recognized HID ballast models and 49 standard
models in stock - one of the most extensive product lines in the industry
UL1029 Temp. Rated : Among the coolest running ballasts in the
industry (low temp > longer life)
Comprehensive EISA/CA Title 20 compliant offering
Vacuum pressure impregnated
High quality silicon steel
Comprehensive line using Class N 200C insulation system
RoHS compliant
Tight, precise winding for lower watt losses and cooler operation
Factory ISO9001/ISO14000 certifed
Automatic Testing Equipment - 100% of production is tested, recorded
and labeled with unique ID for quality tracking
Waveform - Metal Halide & Pulse Start line meets or exceeds stringent
ANSI lamp waveform requirements (VSS, OS, OT, Peak Current,
Crest Factor, di/dt)
Industry Leading Quality. Proven Reliability
Certifcations
Certifcations
Magnetic HID Catalog 2011_Rev2.0.indd 4 11/8/11 11:55 AM
L
a
m
p

S
t
y
l
e
M

-

M
e
t
a
l

H
a
l
i
d
e

P
r
o
b
e

S
t
a
r
t
C

-

M
e
t
a
l

H
a
l
i
d
e

P
u
l
s
e

S
t
a
r
t
C
E
-

M
e
t
a
l

H
a
l
i
d
e

P
u
l
s
e

S
t
a
r
t

E
I
S
A
S
-

H
i
g
h

P
r
e
s
s
u
r
e

S
o
d
i
u
m
Understanding Hatch HID Ballast Part Numbers
Example Part Number: GS1000-ML5-CWCA
C
o
n
f
g
u
r
a
t
i
o
n
W

-

W
i
t
h

W
e
l
d
e
d

B
r
a
c
k
e
t
I

-

W
i
t
h

I
g
n
i
t
o
r
D
C

-

W
i
t
h

D
r
y

F
i
l
m

C
a
p
a
c
i
t
o
r
O
C

-

W
i
t
h

O
i
l

F
i
l
l
e
d

C
a
p
a
c
i
t
o
r
T
A
B
-

T
a
b
s

O
n

B
a
l
l
a
s
t
K

-

R
e
p
l
a
c
e
m
e
n
t

K
i
t
G
S 1000 ML5 CW CA K
B
a
l
l
a
s
t

T
y
p
e
G

-

M
a
g
n
e
t
i
c

H
I
D
V
o
l
t
a
g
e
M
L
T
-

1
2
0
/
2
0
8
/
2
4
0
/
2
7
7
M
L
5
-

1
2
0
/
2
0
8
/
2
4
0
/
2
7
7
/
4
8
0
4
8
T

-

4
8
0

w

1
2
0

a
u
x
i
l
l
a
r
y
A

-

1
2
0
B

-

2
0
8
C

-

2
4
0
C

-

2
7
7
E

-

3
4
7
F

-

4
8
0
C
o
i
l

M
a
t
e
r
i
a
l
C
C

-

C
u

C
u
A
A

-

A
l

A
C
A

-

C
u

A
l
C
C
C
-

C
u

C
u

C
u
W
a
t
t
a
g
e
3
5

-
1
5
0
0

W
a
t
t
s
C
i
r
c
u
i
t

T
y
p
e
C
W
-

C
W
A
H
X

-

H
X

H
P
F
M
R
-

M
a
g

R
e
g
R
N

-

R

N
P
F
R
H

-

R

H
P
F
4 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Part Number Guide
*For information on Replacement Kits
Please see Page 9
Over 350 models and confgurations of Hatch Magnetic HID
Ballasts are available. Only our 49 most popular items are listed in
this catalog. For complete specifcations please visit our website.
Magnetic HID Catalog 2011_Rev2.0.indd 5 11/8/11 11:55 AM
Dimensional Diagrams
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 5
Single Core
Dual Core
Triple Core
Single Core
2.218
2.187
2.625
1.781
B
Max
A
4 Holes>+0.175
Cleared for #6 Bolts
2.218 x 2.625 Core
A
B
2.813
3.938
3.500
2.438
0.195 Min. (4X)
Cleared for #10 bolts
Cleared for #10 bolts
B
MAX
A
4.250
4.375
5.375
6.000
3.875
4 x 6 Core
8 Holes
0.195 Dia Thru
B
MAX
A
4.250
4.375
4.750
3.875
4 x 4 Core
4 Holes >=0.195
Cleared for #10 bolts
0.195 Min. (8X)
4.250
4.375
5.375
3.875
5.750
B
A
Cleared for #10 bolts
Single Core A
Dual Core B
Dual Core C Dual Core D
Triple Core E
* 12" Lead Length
* 12" Lead Length
* 12" Lead Length
* 12" Lead Length
* 12" Lead Length
All measurements in inches
DIAGRAM
DIAGRAM
DIAGRAM
DIAGRAM
DIAGRAM
Magnetic HID Catalog 2011_Rev2.0.indd 6 11/8/11 11:56 AM
General Specifications
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 6
Metal Halide
Metal Halide 175/150 M57/H39/M107 CWA 120 208 240 277 480 GM175-ML5-CWCA 2.44 4.10 Cu Al B
Metal Halide 175/150 M57/H39/M107 CWA 120 208 240 277 GM175-MLT-CWCA 2.44 3.80 Cu Al B
175/150 Watt
Metal Halide 250 M58/H37 CWA 120 208 240 277 480 GM250-ML5-CWCA 1.85 3.6 Cu Al D
Metal Halide 250 M58/H37 CWA 120 208 240 277 GM250-MLT-CWAA 1.61 3.54 Al Al D
250 Watt
Metal Halide 400 M59/H33 CWA 120 208 240 277 480 GM400-ML5-CWCA 2.32 4.26 Cu Al D
Metal Halide 400 M59/H33 CWA 120 208 240 277 GM400-MLT-CWAA 2.16 4.2 Al Al D
400 Watt
Metal Halide 1000 M47/H36 CWA 120 208 240 277 480 GM1000-ML5-CWCA 3.25 5.19 Cu Al C
Metal Halide 1000 M47/H36 CWA 120 208 240 277 GM1000-MLT-CWCA 3.01 4.92 Cu Al C
1000 Watt
Lamp Type
Lamp
Watts
Lamp ANSI
Code
Circuit
Type
Input Volts
Hatch Part
Number
Core
Dimensions (in)
Coil Material
Dimensional
Diagram
A B Pri. Sec.
Metal Halide 1500 M48 CWA 120 208 240 277 GM1500-MLT-CWCC 4.1 6.3 Cu Cu C
Metal Halide 1500 M48 CWA 480 GM1500-48T-CWCC 4.11 5.9 Cu Cu C
1500 Watt
Pulse Start MH 50 M110/M148 HX-HPF 120 208 240 277 GC50-MLT-HXAA 1.04 2.48 Al Al B
50 Watt
Pulse Start MH 70 M98/M143/M139 HX-HPF 120 208 240 277 GC70-MLT-HXCA 1.46 2.9 Cu Al B
Pulse Start MH 70 M98/M143/M139 HX-HPF 480 GC70-48T-HXCC 1.46 2.8 Cu Cu B
70 Watt
Pulse Start MH 100 M90/M140 HX-HPF 120 208 240 277 GC100-MLT-HXCA 1.57 2.95 Cu Al B
Pulse Start MH 100 M90/M140 HX-HPF 480 GC100-48T-HXCC 1.61 2.8 Cu Cu B
100 Watt
Pulse Start Metal Halide
Lamp Type
Lamp
Watts
Lamp ANSI
Code
Circuit
Type
Input Volts Hatch Part Number
Core
Dimensions (in)
Coil Material
Dimensional
Diagram
A B Pri. Sec.
Pulse Start MH 150 M102/M142 HX-HPF 120 208 240 277 GC150-MLT-HXCA 2.28 3.8 Cu Al B
Pulse Start MH 150 M102/M142 HX-HPF 480 GC150-48T-HXCC 2.3 3.9 Cu Cu B
150 Watt
Pulse Start MH 175 M137/M152 CWA-Pulse 120 208 240 277 480 GC175-ML5-CWCC 2.42 3.5 Cu Cu B
Pulse Start MH 175 M137/M152 CWA-Pulse 120 208 240 277 GC175-MLT-CWCC 2.05 3.5 Cu Cu B
175 Watt
Dimensional Diagrams can be found on Pg. 5
Magnetic HID Catalog 2011_Rev2.0.indd 7 11/8/11 11:56 AM
General Specifications
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 7
Pulse Start
MH
250 M138/M153
CWA-
Pulse
120 208 240 277 480 GC250-ML5-CWCA 1.99 3.9 Cu Al D
Pulse Start
MH
250 M138/M153
CWA-
Pulse
120 208 240 277 GC250-MLT-CWCA 1.85 3.78 Cu Al D
250 Watt
Pulse Start
MH
320 M132/M154
CWA-
Pulse
120 208 240 277 480 GC320-ML5-CWCA 2.18 4.4 Cu Al D
Pulse Start
MH
320 M132/M154
CWA-
Pulse
120 208 240 277 GC320-MLT-CWAA 2.18 4.4 Al Al D
320 Watt
Pulse Start
MH
400 M153/M138
CWA-
Pulse
120 208 240 277 480 GCE400-ML5-CWCA 2.32 4.25 Cu Al D
Pulse Start
MH
400 M135
CWA-
Pulse
120 208 240 277 GCE400-MLT-CWAA 2.32 4.2 Al Al D
400 Watt
Pulse Start
MH
350 M131
CWA-
Pulse
120 208 240 277 480 GCE350-ML5-CWCA 2.32 4.40 Cu Al D
Pulse Start
MH
350 M131
CWA-
Pulse
120 208 240 277 GCE350-MLT-CWCA 2.32 4.4 Cu Al D
350 Watt
Pulse Start Metal Halide
Lamp Type
Lamp
Watts
Lamp ANSI
Code
Circuit
Type
Input Volts Hatch Part Number
Core
Dimensions (in)
Coil Material
Dimensional
Diagram
A B Pri. Sec.
Pulse Start
MH
750/775 M149/M181
CWA-
Pulse
120 208 240 277 480 GC750-ML5-CWCA 2.83 4.8 Cu Al C
Pulse Start
MH
750 M149/M181
CWA-
Pulse
120 208 240 277 GC750-MLT-CWCA 2.62 4.8 Cu Al C
750 Watt
1000 Watt
Pulse Start
MH
1000/
875
M141/M166/M47
CWA-
Pulse
120 208 240 277 480 GC1000-ML5-CWCA 3.25 5.22 Cu Al C
Pulse Start
MH
1000/
875
M141/M166/M47
CWA-
Pulse
120 208 240 277 GC1000-MLT-CWCA 3.01 5.05 Cu Al C
High Pressure Sodium
35 Watt
High Pressure
Sodium
35 S76 R-NPF 120 GS35-A-RNC 0.61 1.8 Cu A
Lamp Type
Lamp
Watts
Lamp ANSI
Code
Circuit
Type
Input Volts Hatch Part Number
Core
Dimensions (in)
Coil Material
Dimensional
Diagram
A B Pri. Sec.
50 Watt
High Pressure
Sodium
50 S68 HX-HPF 120 208 240 277 GS50-MLT-HXCA 1.03 2.52 Cu Al B
High Pressure
Sodium
50 S68 R-NPF 120 GS50-A-RNC 0.83 2.0 Cu A
Dimensional Diagrams can be found on Pg. 5
Magnetic HID Catalog 2011_Rev2.0.indd 8 11/8/11 11:56 AM
General Specifications
8 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33
High Pressure Sodium
100 Watt
High Pressure
Sodium
100 S54 HX-HPF 120 208 240 277 GS100-MLT-HXCA 1.97 3.35 Cu Al B
High Pressure
Sodium
100 S54 HX-HPF 480 GS100-48T-HXCC 1.99 3.4 Cu Cu B
High Pressure
Sodium
100 S54 R-NPF 120 GS100-A-RNA 1.77 2.95 Al A
150 Watt
High Pressure
Sodium
150 S55 HX-HPF 120 208 240 277 GS150-MLT-HXCA 2.56 4.05 Cu Al B
High Pressure
Sodium
150 S55 HX-HPF 480 GS150-48T-HXCC 3.0 4.3 Cu Cu B
High Pressure
Sodium
150 S55 R-NPF 120 GS150-A-RNA 2.36 3.54 Al A
70 Watt
High Pressure
Sodium
70 S62 HX-HPF 120 208 240 277 GS70-MLT-HXCA 1.54 2.95 Cu Al B
High Pressure
Sodium
70 S62 HX-HPF 480 GS70-48T-HXCC 1.85 3.2 Cu Cu B
High Pressure
Sodium
70 S62 R-NPF 120 GS70-A-RNC 1.3 2.5 Cu A
Lamp Type
Lamp
Watts
Lamp ANSI
Code
Circuit
Type
Input Volts Hatch Part Number
Core
Dimensions (in)
Coil Material
Dimensional
Diagram
A B Pri. Sec.
400 Watt
High Pressure
Sodium
400 S51 CWA 120 208 240 277 480 GS400-ML5-CWCA 2.56 4.7 Cu Al D
High Pressure
Sodium
400 S51 CWA 120 208 240 277 GS400-MLT-CWCA 2.32 4.18 Cu Al D
1000 Watt
High Pressure
Sodium
1000 S52 CWA 120 208 240 277 480 GS1000-ML5-CWCA 4.1 6.1 Cu Al C
High Pressure
Sodium
1000 S52 CWA 120 208 240 277 GS1000-MLT-CWCA 4.33 6.4 Cu Al C
250 Watt
High Pressure
Sodium
250 S50 CWA 120 208 240 277 480 GS250-ML5-CWCA 1.97 3.9 Cu Al D
High Pressure
Sodium
250 S50 CWA 120 208 240 277 GS250-MLT-CWCA 1.85 3.5 Cu Al D
FX: 813.288.8105 8
Dimensional Diagrams can be found on Pg. 5
Magnetic HID Catalog 2011_Rev2.0.indd 9 11/8/11 11:56 AM
Replacement Kit Information &
Troubleshooting
9 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
The Replacement Kit consists of a ballast with input voltage connections rated for
120, 208, 240 or 277 volts and 480 volts on some models, capacitor, mounting
brackets and nuts and bolts which permit field replacement of a ballast in a High
Intensity Discharge type lamp fixture. The replacement kit includes mounting brackets
and bolts which may be reworked to match the old ballast mounting position. Be sure
that the brackets secure the components in the fixture so that installation and
vibration will not change the location of these components.
Troubleshooting:

CAUTION: The following troubleshooting procedures are to be
performed only by a qualified electrician. When checking connections
or interchanging components, the power must be turned off.
If a malfunction occurs:
Be sure all connections to the line, capacitor (if required) and lamp have
been property made.
Measure voltage to determine whether it is within tolerance specified
for the ballast being used.
Check for blown fuse or tripped circuit breaker. If power interruption has
occurred, check each fixture component for possible shorting or grounding.
Try lamp on another ballast known to be operating properly or try another
lamp on the ballast in question. Make sure lamp and ballast are properly
matched in terms of wattage and type.
In the High Pressure Sodium Lamp system, be sure lead marked lamp
on starting aid is connected to center eyelet of lamp socket.
In the High Pressure Sodium Lamp system, to determine if starting aid
is faulty, test by substituting another starting aid.
Magnetic HID Catalog 2011_Rev2.0.indd 10 11/8/11 11:56 AM
10 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
To view a complete Hatch
Product Catalog, scan this
barcode with your Smartphone.
Since 1985, Hatch has been the recognized market leader in
the design and manufacture of premium power lighting products
and solutions. Hatch offers a complete line of electronic and
magnetic ballasts and transformers for virtually all lighting
applications and is one of the largest independent, full-line power
supply manufacturers in the world.
Current Hatch products include:
Electronic LED Drivers
Electronic HID Ballasts
Linear Fluorescent Ballasts
Compact Fluorescent Ballasts
Electronic Low Voltage Transformers
Remote Transformers
Magnetic HID Ballasts
Fluorescent Lamps
Sign Ballasts
Dont have a scanning App? Search the Apple App Store,
Android Market or BlackBerry App World for a barcode
scanning application
Electrical data and product specifications in this
catalog are subject to change without notice
About Hatch
Magnetic HID Catalog 2011_Rev2.0.indd 11 11/8/11 11:56 AM
Hatch Transformers, Inc.
Global Headquarters
7821 Woodland Center Blvd.
Tampa, FL 33614
P: 813.288.8006
F: 813.288.8105
www.hatchlighting.com
REV: 2.0 111027
B A L L A S T S , D R I V E R S , T R A N S F O R M E R S & L A M P S F O R A L L L I G H T I N G A P P L I C A T I O N S
Magnetic HID Catalog 2011_Rev2.0.indd 12 11/8/11 11:56 AM
Precision Power. Perfect Light.
ELECTRONIC
LOW VOLTAGE
TRANSFORMERS
B A L L A S T S , D R I V E R S , T R A N S F O R M E R S & L A M P S F O R A L L L I G H T I N G A P P L I C A T I O N S
Electronic Transformer Catalog 2011_Rev2.0.indd 1 11/7/11 4:59 PM
Electronic Transformers
Electronic transformers were
among the frst products
ever offered by Hatch to the
lighting industry. They have
since proven to be the most
reliable transformers available
in the marketplace. Hatch
low voltage transformers
have been engineered and
perfected over three decades
to provide industry leading
performance and fexibility
for all your low voltage
lighting needs.
Industry Leading Reliability
Moisture Resistance
No Emission of Audible Noise
Low Harmonic Distortion
High Power Factor
Lightweight, Compact Designs
and Confgurations
Small Case Sizes
Fully Dimmable
Interoperability With Most 120V
Commercially Available
Dimmers (Note: three-wire
dimmers labeled for electronic
transformers are recommended
for optimum performance)
All Hatch Electronic Transformers Feature:
w
w
w
.
h
a
t
c
h
l
i
g
h
t
i
n
g
.
c
o
m
1
Electronic Transformer Catalog 2011_Rev2.0.indd 2 11/7/11 4:59 PM
Table of Contents
Intro: Electronic Low Voltage Transformers
Table of Contents
Part Number Guide &
Legacy Series Transformers
Technological Innovations in
Low Voltage Transformers
Hardwire Transformer Case Styles
Knockout Transformer Case Styles
Plug-In Transformer Case Styles
Hardwire Transformer Specifcations
Knockout Transformer Specifcations
Plug-In Transformer Specifcations
Wiring Diagrams
Installation & Testing Guidelines
Products By Hatch
1
2
4
Electrical/Mechanical Specifcations
For All Models
1
3
3
1
4
-
1
6
1
7
1
8
5
-
8
9
-
1
1
1
2
1
9
-
2
0
2
1
2
2
2 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
To view complete online Electronic
Transformer specifcations, scan this
barcode with your Smartphone.
Dont have a scanning App? Search the Apple App Store,
Android Market or BlackBerry App World for a barcode
scanning application
Electronic Transformer Catalog 2011_Rev2.0.indd 3 11/7/11 4:59 PM
T
e
c
h
n
o
l
o
g
i
c
a
l

I
n
n
o
v
a
t
i
o
n
s

I
n

E
l
e
c
t
r
o
n
i
c

T
r
a
n
s
f
o
r
m
e
r
s
Soft Start Circuitry
First implemented in 1992, all Hatch Transformers use soft-start circuitry to
maximize lamp life. The soft-start circuit ramps up the lamp flament voltage
slowly when the lamp is cold, thus prolonging the life of the lamp.
Electronic Short-Circuit Protection (ESP)
First implemented in 1991, all Hatch low voltage transformers utilize ESP,
electronic short circuit and over load protection. The ESP sensing circuit will
instantly shut down the output before any of the components are stressed if
a short circuit or overload is detected. The transformer will automatically rest
as soon as the fault is corrected.
The Electronic Advantage
Electronic low voltage transformers are very small and light compared
to magnetic low voltage transformers. In most cases, they are small
enough that fxture manufacturers can often incorporate them within their
lighting fxtures rather than having to mount them remotely. Even when not
incorporated within the lighting fxture, an electronic low voltage transformer
is very easy to install in a small hidden location. Electronic transformers
also incorporate a number of advanced technologies like soft start and
short circuit protection which prolong lamp life, protect lamps during power
surges and safely shuts down lamps at the end of life.
Certifcations
Certifcations
3
Electronic Transformer Catalog 2011_Rev2.0.indd 4 11/7/11 4:59 PM
Legacy Series Electronic Transformers
Understanding Hatch Transformer Part Numbers
Example Part Number: RS12-80-277WD
4 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Part Number Guide
Legacy Series Transformers
Since 1985 Hatch has developed several electronic transformers that have become the industry
standard in several lighting fxtures that are still sold and produced today. While many of these
transformers are no longer part of our current product catalog, we continue to sell and support
several of our Legacy Series models. Hatch Legacy Series transformer models beginning with VS,
VE, VJ, TS and RS 108 are available as replacement parts or in large quantities by special order.
RS 12 80 277 WD
T
r
a
n
s
f
o
r
m
e
r

T
y
p
e
R
S
-
H
a
rd
w
ire
E
le
c
tro
n
ic

P
S
-
P
lu
g
-
In
E
le
c
tro
n
ic
1
2
0
V
O
u
t
p
u
t

V
o
l
t
a
g
e
1
2

-
1
2
V
o
lts
2
4

-
2
4
V
o
lts
M
a
x
i
m
u
m

W
a
t
t
a
g
e
2
0

-
2
0
W
a
tts
4
0

-
4
0
W
a
tts
5
0

-
5
0
W
a
tts
6
0

-
6
0
W
a
tts
7
5

-
7
5
W
a
tts
C
a
s
e

D
e
s
c
r
i
p
t
i
o
n
s
B
F
(B
F
S
) -
B
o
tto
m
F
e
e
d
S
tu
d
s
K
O

-
K
n
o
c
k
o
u
t s
e
r
ie
s
M

-
M
e
ta
l
M
G

-
G
ro
u
n
d
w
ire
w
/
te
r
m
in
a
l
M
G
N
-
G
ro
u
n
d
w
ire
w
/
o
te
r
m
in
a
l
W
D

-
B
lu
e
D
im
m
in
g
L
o
o
p
J

-
L
e
a
d
s
o
u
t o
p
p
o
s
ite
e
n
d
s
I
n
p
u
t

V
o
l
t
a
g
e
1
2
0
V
o
lts
-
N
o
M
a
r
k
in
g




(i.e
. R
S
1
2
-
6
0
M
)
2
3
0

-

2
3
0
V
o
lts
2
7
7

-

2
7
7
V
o
lts
VS Plastic Case Hardwire
Transformer 120V
VS12-60WNW
VS12-60WD
VS24-60W
VS12-60SGK
VS12-75W
VS12-75WD
VS12-105J
VS12-150JNW
VS24-150J
VE Plastic Case Hardwire
Transformer 230V
VE12-60W
VE12-75W
VJ Plastic Case Hardwire
Transformer 277V
VJ12-75W
TS Touch Dimming
Transformers
TS12-60S
RS108 Watt Specialty Metal
Case Hardwire Transformer
RS12-108
RS12-108BF
RS24-108
RS12-108-277
RS12-108-277BF
Full electronic specifcations for all
Legacy Series Transformers can be found
on our website.
8
0

-
8
0
W
a
tts
1
0
5
-
1
0
5
W
a
tts
1
5
0
-
1
5
0
W
a
tts
3
0
0
-
3
0
0
W
a
tts
Electronic Transformer Catalog 2011_Rev2.0.indd 5 11/7/11 4:59 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 5
Hardwire Transformers
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output Volts Input Amps
Output
Amps
Case
Style
Wire
Diagram
Safety
Listing
20 5
RS12-20
120
11.5
0.17
1.8
A
I
UL/C-UL
Recognized,
Class 2
RS12-20BF C
RS12-20-277*
277 0.07
A
RS12-20-277BF* E
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output Volts Input Amps
Output
Amps
Case
Style
Wire
Diagram
Safety
Listing
40 5
RS12-40
120
11.5
0.34
3.5
A
I
UL/C-UL
Recognized,
Class 2
RS12-40BF C
RS12-40-277*
277 0.14
A
RS12-40-277BF* E
20 WATT
20, 40, 50, 60 & 80
Watt Models
40 WATT
NOTE: Must use a minimum of 10 watts when using dimmers. It is also important to confrm dimming controls compatibility with the manufacturer and
your Hatch representative.
NOTE: Must use a minimum of 10 watts when using dimmers. It is also important to confrm dimming controls compatibility with the manufacturer and
your Hatch representative.
*277V Dimming is not recommended
*277V Dimming is not recommended
Case Styles and Dimensions can be found on Pgs. 14-18 | Wire Diagrams can be found on Pgs. 19-20
Electronic Transformer Catalog 2011_Rev2.0.indd 6 11/7/11 4:59 PM
Hardwire Transformers
6 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output
Volts
Input Amps
Output
Amps
Case
Style
Wire
Diagram
Safety
Listing
60 5
RS12-60M
120 11.5 0.5 5.3
A
I
UL/C-UL
Recognized,
Class 2
RS12-60MWD II
RS12-60-BF C I
60 WATT
NOTE: Must use a minimum of 10 watts when using dimmers. It is also important to confrm dimming controls compatibility with the manufacturer and
your Hatch representative.
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output Volts Input Amps
Output
Amps
Case
Style
Wire
Diagram
Safety
Listing
80 5
RS12-80M
120
11.5
0.67
7.0
A I
UL/C-UL
Recognized
RS12-80MG A IV
RS12-80MGN A IV
RS12-80WD A III
RS12-80BFS C I
RS24-80 23.5 3.4 A I
RS12-80-230 230
11.5
0.35 7.0 A I
RS12-80-277*
277 0.29 7.0
A I
RS12-80-277WD* B III
RS12-80-277BF* E I
80 WATT
NOTE: Must use a minimum of 10 watts when using dimmers. It is also important to confrm dimming controls compatibility with the manufacturer and
your Hatch representative.
*277V Dimming is not recommended
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output Volts Input Amps
Output
Amps
Case
Style
Wire
Diagram
Safety
Listing
50 5
RS12-50
120
11.5
0.42
4.4
A
I
UL/C-UL
Recognized,
Class 2
RS12-50BF C
RS12-50-277*
277 0.18
A
RS12-50-277BF* E
50 WATT
NOTE: Must use a minimum of 10 watts when using dimmers. It is also important to confrm dimming controls compatibility with the manufacturer and
your Hatch representative.
*277V Dimming is not recommended
Case Styles and Dimensions can be found on Pgs. 14-18 | Wire Diagrams can be found on Pgs. 19-20
Electronic Transformer Catalog 2011_Rev2.0.indd 7 11/7/11 4:59 PM
Hardwire Transformers
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 7
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output Volts Input Amps
Output
Amps
Case
Style
Wire
Diagram
Safety
Listing
105 5
RS12-105
120
11.5
0.88
9.13
D
I
UL/C-UL
Recognized
RS12-105BF E
RS12-105-277*
277 0.38
D
RS12-105-277BF* E
105 WATT
NOTE: Must use a minimum of 10 watts when using dimmers. It is also important to confrm dimming controls compatibility with the manufacturer and
your Hatch representative.
*277V Dimming is not recommended
105 Watt
Models
Case Styles and Dimensions can be found on Pgs. 14-18 | Wire Diagrams can be found on Pgs. 19-20
Electronic Transformer Catalog 2011_Rev2.0.indd 8 11/7/11 5:00 PM
Hardwire Transformers
8 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output Volts Input Amps
Output
Amps
Case
Style
Wire
Diagram
Safety
Listing
150 10
RS12-150
120
11.5
1.25
13.05
F
II
UL/C-UL
Recognized
RS12-150BF G
RS24-150 23.5 6.39 F
RS12-150-277*
277 11.5 0.55 13.05
F
RS12-150-277BF* G
150 WATT
*277V Dimming is not recommended
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output Volts Input Amps
Output
Amps
Case
Style
Wire
Diagram
Safety
Listing
300 50
RS12-300
120
11.5 2.5 26.1
H
I
UL/C-UL
Recognized
RS12-300BF J
RS12-300-277* 277 K
300 WATT Rectangular
300 WATT Round
*277V Dimming is not recommended
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output Volts Input Amps
Output
Amps
Case
Style
Wire
Diagram
Safety
Listing
300 50 RS12-300RL 120 11.5 2.5 26.1 I VI
UL/C-UL
Recognized
NOTE FOR ROUND RL MODEL: Heat sinking is highly recommended in order to maintain temperature requirements.
150 Watt Models
300
Watt Models
NOTE: Must use a minimum of 75 watts when using dimmers. It is also important to confrm dimming controls compatibility with the manufacturer and
your Hatch representative.
NOTE: Must use a minimum of 50 watts when using dimmers. It is also important to confrm dimming controls compatibility with the manufacturer and
your Hatch representative.
Case Styles and Dimensions can be found on Pgs. 14-18 | Wire Diagrams can be found on Pgs. 19-20
Electronic Transformer Catalog 2011_Rev2.0.indd 9 11/7/11 5:00 PM
9 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Knockout Transformers
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output
Volts
Input
Amps
Output
Amps
Case
Color
Case
Style
Wire
Diagram
Safety
Listing
150 10
RS12-150KO*
120
11.5
1.25
13.05 Black or White
M II ETL Listed
RS24-150KO* 23.5 6.39 Black or White
KO 150 WATT
NOTE: Must use a minimum of 50 watts when using dimmers. It is also important to confrm dimming controls compatibility with the manufacturer and
your Hatch representative.
*White cases are designated by adding a W at the end of the part number (i.e. RS12-60KOW).
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output
Volts
Input
Amps
Output
Amps
Case
Color
Case
Style
Wire
Diagram
Safety
Listing
60 5
RS12-60KO*
120
11.5
0.5
5 Black or White
L II
ETL Listed,
Class 2
RS24-60KO* 23.5 2.5 Black or White
KO 60 WATT
NOTE: Must use a minimum of 10 watts when using dimmers. It is also important to confrm dimming controls compatibility with the manufacturer and
your Hatch representative.
*White cases are designated by adding a W at the end of the part number (i.e. RS12-60KOW).
1.5
1.43
6
.4

1.56
1.68
7
.1
8

Hatch Knockout Transformers have been designed around our robust and reliable
RS-Series transformers and are fully encased in custom steel enclosures. All knockout
transformers come in both black and white steel cases with several knockout holes to
facilitate custom wiring and mounting configurations. Models are available in 60, 150,
180, 300 & 360 Watts.
About Hatch Knockout Transformers:
Case Styles and Dimensions can be found on Pgs. 14-18 | Wire Diagrams can be found on Pgs. 19-20
Electronic Transformer Catalog 2011_Rev2.0.indd 10 11/7/11 5:00 PM
10
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Knockout Transformers
KO 180 WATT
* NOTE: KO Models are multiple RS12-60M transformers
in a single case.
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output
Volts
Input
Amps
Output
Amps
Case
Color
Case
Style
Wire
Diagram
Safety
Listing
60 X 3 5 X 3
RS12-180KO*
120
11.5
0.5
5 Black or White
N V
ETL Listed,
Class 2
RS24-180KO* 23.5 2.5 Black or White
NOTE: Must use a minimum of 10 X 3 watts when using dimmers. It is also important to confrm dimming controls compatibility with the manufacturer
and your Hatch representative.
*White cases are designated by adding a W at the end of the part number (i.e. RS12-60KOW).
NOTE: Must use a minimum of 75 watts when using dimmers.
*White cases are designated by adding a W at the end of the part number (i.e. RS12-60KOW).
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output
Volts
Input
Amps
Output
Amps
Case
Color
Case
Style
Wire
Diagram
Safety
Listing
300 50
RS12-300KO*
120
11.5
2.5
26.1 Black or White
O II ETL Listed
RS24-300KO* 23.5 12.8 Black or White
KO 300 WATT
1.68
1.81
1
1
.0
6

Case Styles and Dimensions can be found on Pgs. 14-18 | Wire Diagrams can be found on Pgs. 19-20
1.63
4
.7
0

5
.
1
0

Electronic Transformer Catalog 2011_Rev2.0.indd 11 11/7/11 5:00 PM


11 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Knockout Transformers
* NOTE: KO Models are multiple RS12-60M
transformers in a single case.
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output
Volts
Input
Amps
Output
Amps
Case
Color
Case
Style
Wire
Diagram
Safety
Listing
60 X 6 5 X 6
RS12-360KO*
120
11.5
2.5
26.1 Black or White
P VII
ETL Listed,
Class 2
RS24-360KO* 23.5 12.8 Black or White
KO 360 WATT
NOTE: Must use a minimum of 10 X 3 watts when using dimmers. It is also important to confrm dimming controls compatibility with the manufacturer
and your Hatch representative.
*White cases are designated by adding a W at the end of the part number (i.e. RS12-60KOW).
Case Styles and Dimensions can be found on Pgs. 14-18 | Wire Diagrams can be found on Pgs. 19-20
1.63
4
.7
0

8
.
3
0

Electronic Transformer Catalog 2011_Rev2.0.indd 12 11/7/11 5:00 PM


12 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Plug-In Transformers
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output Volts Input Amps
Output
Amps
Case
Color
Case
Style
Safety
Listing
20 10
PS12-20LB
120 11.5 0.16 1.7
Black Q UL/C-UL
Listed
Class 2 PS12-20LW White Q
Black
White
20 WATT
NOTE: It is imperative to confrm dimming control compatibility with the manufacturer and your Hatch representative.
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output Volts Input Amps
Output
Amps
Case
Color
Case
Style
Safety
Listing
75 20 PS12-75LB 120 11.5 0.63 6.3 Black R
UL/C-UL
Listed
Max
Watts
Min
Watts
Hatch
Part
Number
Input
Volts
Output Volts Input Amps
Output
Amps
Case
Color
Case
Style
Safety
Listing
60 20
PS12-60LB
120 11.5 0.52 5.2
Black R UL/C-UL
Listed
Class 2 PS12-60LW White R
60 WATT
75 WATT
NOTE: It is imperative to confrm dimming control compatibility with the manufacturer and your Hatch representative.
NOTE: It is imperative to confrm dimming control compatibility with the manufacturer and your Hatch representative.
20, 60 & 75
Watt Models
Case Styles and Dimensions can be found on Pgs. 14-18 | Wire Diagrams can be found on Pgs. 19-20
Electronic Transformer Catalog 2011_Rev2.0.indd 13 11/7/11 5:00 PM
13 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Electrical/Mechanical Specifications
Model
Series
Maximum
Case
Temperature
Sound
Rating
Environmental
Protection
Weight
Power
Factor
Operating
Frequency
Total
Harmonic
Distortion
Input
Leads
Output
Leads
RS
20/40/50
60/75/80
Watts
90C
A+
Epoxy Sealed
for moisture
resistance and
shock/vibration
resistance
2.4 oz
>0.95 25KHz 20%
6, 18AWG
stranded,
105C
stripped
3
/
8

tinned
6, 18AWG
stranded,
105C
stripped
3
/
8

tinned
RS 80
Watt
277
80C
2.4 oz
RS
105/108
Watts
4 oz
6, 18AWG
stranded,
105C
stripped
3
/
8

tinned
6, 18AWG
stranded,
105C
stripped
3
/
8

tinned
RS
150
Watt
6.4 oz
RS
300 Watt
Rectangular
12.8 oz
RS
300 Watt
Round
15.3 oz
9, 18AWG
stranded,
105C
stripped
3
/
8

tinned
8, 12AWG
stranded,
105C
stripped
3
/
8

tinned
RS
60 Watt KO
90
A+
Epoxy Sealed
for moisture
resistance and
shock/vibration
resistance
9.8 oz
>0.95 25KHz 20%
2 input
connector,
accepting
14-22 AWG
wire types
3 output
connector,
accepting
14-22 AWG
wire types
NOTE: 1
connector for
ground
RS
150 Watt KO
80C
14.7 oz
RS
180 Watt KO
18.4 oz
RS
300 Watt KO
29 oz
RS
360 Watt KO
30.8 oz
PS
60/75 Watt
80C A+
Epoxy Sealed
for moisture
resistance and
shock/vibration
resistance
4 oz
>0.95 25KHz 20%
Standard
120Vac Plug
10, SPT-2
cord
PS
105/150 Watt
9.5 oz
NOTE: All BF models have a stud length of 0.3-0.31, a thread of
8
/
32
and a thread pitch of 2
Electronic Transformer Catalog 2011_Rev2.0.indd 14 11/7/11 5:00 PM
14 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Hardwire Transformer Case Styles
* Side Lead
2
.
2
0

0.75
1.23
All measurements in inches
0.81
1.30
1
.
3
0

* Side Lead
1.30
0.80
2
.
7
2

2
.
0

* With studs
1.30
0.81
3
.
0
3

* Side Lead
RS 20 through 80 Watt A
RS with Dimming Loop B
RS 105 Watt D
RS 20 through 80 Bottom Feed C
CASE STYLE
CASE STYLE
CASE STYLE
CASE STYLE
.375 height
8/32 thread
Electronic Transformer Catalog 2011_Rev2.0.indd 15 11/7/11 5:00 PM
2
.
0

3
.
3
1

1.00
1.53
RS 150 Bottom Feed
* With studs
1.53
1.00
3
.
3
1

3
.
7
3

3
.
8
8

* Side Lead
15 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Hardwire Transformer Case Styles
1.27
5
.8
5

1
.
7
0

6
.4
1

* Side Lead w/Feet


* With studs
1.30
0.81
3
.
0
3

2
.
0

All measurements in inches


RS 300 Watt H
RS 150 Bottom Feed G
RS 150 Watt F
RS 105 Bottom Feed E
CASE STYLE
CASE STYLE
CASE STYLE
CASE STYLE
.375 height
8/32 thread
.375 height
8/32 thread
Electronic Transformer Catalog 2011_Rev2.0.indd 16 11/7/11 5:00 PM
* Side Lead w/o Feet
* Round case w/center mounting hole
1.27
5
.8
5

1
.7
0

16 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Hardwire Transformer Case Styles
3
.6
2

4
.8
0

1.61
2

* With studs
1.29
3.62
5
All measurements in inches
RS 300 Bottom Feed K
RS 300 Watt RL J
RS 300 Watt I
CASE STYLE
CASE STYLE
CASE STYLE
.375 height
8/32 thread
Electronic Transformer Catalog 2011_Rev2.0.indd 17 11/7/11 5:00 PM
1.68
1.81
1
1
.0
6

* Three 3/4 knockouts on each end of the


case. Total of six knockouts.
* RS-360KO Models contain six RS12-60M
transformers in a single case
* Six 3/4 knockouts on one 8.30 side of
the case and two 3/4 knockouts on back
left corner. Total of eight knockouts.
17 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Knockout Case Styles
1.5
1.43
6
.4

* RS-180KO Models contain three RS12-60M


transformers in a single case
* Four 3/4 knockouts on one 5.10" side of the
case and two 3/4" knockouts on back left
corner. Total of six knockouts.
1.63
4
.7
0

5
.
1
0

1.56
1.68
7
.1
8

All measurements in inches


RS-KO 360 Watt P
RS-KO 300 Watt O
RS-KO 180 Watt N
RS-KO 150 Watt M
RS-KO 60 Watt L
CASE STYLE
CASE STYLE
CASE STYLE
CASE STYLE
CASE STYLE
* Three 3/4 knockouts on each end of the
case. Total of six knockouts.
* Three 3/4 knockouts on each end of the
case. Total of six knockouts.
1.63
4
.7
0

8
.
3
0

Electronic Transformer Catalog 2011_Rev2.0.indd 18 11/7/11 5:00 PM


1.75
Nickel-Plated Hospital
Grade 120 Volt Plug
Wire: 10 feet of
SPT-1 or SPT-2
18AWG, 105C,
stripped and tinned 3/8
2.75
.9371
1.75
Nickel-Plated Hospital
Grade 120 Volt Plug
Wire: 10 feet of
SPT-1 or SPT-2
18AWG, 105C,
stripped and tinned 3/8
2.75
.9371
18 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Plug-In Transformer Case Styles All measurements in inches
PS 60-75 Watt Plug-In R
PS 20 Watt Plug-In Q
CASE STYLE
CASE STYLE
Electronic Transformer Catalog 2011_Rev2.0.indd 19 11/7/11 5:00 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 19
Wire Diagrams
Halogen Lamps
I.
BLACK
WHITE
RED
RED
OUTPUT(Lamps)
TRANSFORMER
INPUT
II.
III.
BLACK
BLUE
WHITE
RED
RED
OUTPUT(Lamps)
TRANSFORMER
INPUT
IV.
BLACK
WHITE
GREEN
RED
RED
OUTPUT
GROUND
TRANSFORMER
INPUT
Halogen Lamps
Halogen Lamps
Halogen Lamps
RED
BLACK
RED
WHITE
OUTPUT
TRANSFORMER
INPUT
(Lamps)
BLUE LOOP for Dimm
with 1 meg ohm linear
taper potentiometer
Electronic Transformer Catalog 2011_Rev2.0.indd 20 11/7/11 5:00 PM
VI.
VII.
20 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Wire Diagrams
BLACK
WHITE
RED
RED
TRANSFORMER
V.
Halogen Lamps
Halogen Lamps
Halogen Lamps
OUTPUT
R
E
D
G
r
e
e
n
G
R
O
U
N
D
I
N
P
U
T
R
E
D
R
E
D
R
E
D
R
E
D
R
E
D
OUTPUT
G
r
e
e
n
G
R
O
U
N
D
I
N
P
U
T
R
E
D
R
E
D
R
E
D
R
E
D
R
E
D
R
E
D
R
E
D
R
E
D
R
E
D
R
E
D
R
E
D
R
E
D
Each OUTPUT:
Min 1 X 5W Lamps
Max 3 X 20W Lamps
Each OUTPUT:
Min 1 X 5W Lamps
Max 3 X 20W Lamps
Electronic Transformer Catalog 2011_Rev2.0.indd 21 11/7/11 5:00 PM
I nst al l at i on and Test i ng Gui del i nes f or
El ectroni c Low Vol tage Transformers
21 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Wiring and installation of electronic low voltage transformers
Please make certain that the black and white input wires (primary side) of the low
voltage transformer are connected to the power line (120 volts or 277 volts) using
wire nuts. Also make sure that the two red output wires (secondary side) of the low
voltage transformer are connected to the low voltage light source using wire terminal
blocks of the appropriate size. Low voltage halogen or low voltage xenon lighting
systems carry relatively large currents so all of the low voltage connections must be
very tight to prevent arcing (a possible fire hazard) within those connections.
Testing of electronic low voltage transformers
Hatch low voltage transformers are designed with short circuit protection and a
no-load detection circuit design. This means that a proper load must be present to
detect a voltage across the transformer. Without a load, a voltage meter will read
zero volts. In addition, you must use a digital volt meter capable of reading 25KHz or
higher waveforms. We suggest a Fluke Model 5220A or another equivalent meter.
Remote Mounting
Hatch low voltage transformers can be remote mounted at distances of up to
ten feet.
RS Mounting Options: These models are available with straps or double sided tape.
Please contact your representative for more information.
Delayed start up with Soft-Start Circuitry
Hatch low voltage transformers are designed with soft start circuitry which slowly
ramps up voltage to maximize lamp life. This results in the lamps starting at the
lowest dimming setting and slowly ramping up to full intensity.
Electronic Transformer Catalog 2011_Rev2.0.indd 22 11/7/11 5:00 PM
22 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
About Hatch
To view a complete Hatch
Product Catalog, scan this
barcode with your Smartphone.
Since 1985, Hatch has been the recognized market leader in
the design and manufacture of premium power lighting products
and solutions. Hatch offers a complete line of electronic and
magnetic ballasts and transformers for virtually all lighting
applications and is one of the largest independent, full-line power
supply manufacturers in the world.
Current Hatch products include:
Electronic LED Drivers
Electronic HID Ballasts
Linear Fluorescent Ballasts
Compact Fluorescent Ballasts
Electronic Low Voltage Transformers
Remote Transformers
Magnetic HID Ballasts
Fluorescent Lamps
Sign Ballasts
Dont have a scanning App? Search the Apple App Store,
Android Market or BlackBerry App World for a barcode
scanning application
Electrical data and product
specifications in this catalog are
subject to change without notice
Electronic Transformer Catalog 2011_Rev2.0.indd 23 11/7/11 5:00 PM
Hatch Transformers, Inc.
Global Headquarters
7821 Woodland Center Blvd.
Tampa, FL 33614
P: 813.288.8006
F: 813.288.8105
www.hatchlighting.com
REV: 2.0 111027
B A L L A S T S , D R I V E R S , T R A N S F O R M E R S & L A M P S F O R A L L L I G H T I N G A P P L I C A T I O N S
Electronic Transformer Catalog 2011_Rev2.0.indd 24 11/7/11 5:00 PM
Precision Power. Perfect Light.
COMPACT & LINEAR
FLUORESCENT BALLASTS
& LAMPS
B A L L A S T S , D R I V E R S , T R A N S F O R M E R S & L A M P S F O R A L L L I G H T I N G A P P L I C A T I O N S
Fluorescent Ballast Catalog 2011_Rev2.0.indd 1 11/8/11 12:49 PM
Compact & Linear Fluorescent Ballasts
Hatch is proud to introduce
a broad line of Compact and
Linear Fluorescent Ballasts.
As with all Hatch products,
our Fluorescent product line
meets or exceeds industry
standards for quality and
reliability. With over two
decades of experience you
can trust Hatch Fluorescent
products to save energy and
run your lamps at maximum
effciency.
UL and RoHS certifcation on all
ballasts. CEE Certifcation, CEC
certifcation, Energy Star listing,
DOE and NEMA Premium
Certifcation available on select
models
UL 935 Listed for Hazardous
Location Installations
Programmed Start, Rapid Start
and Instant Start models
Industry standard case sizes and
multiple mounting options
5-year limited warranty offered on
all NEMA Premium and
Programmed Start models
3-year limited warranty on all
standard ballasts
Extended warranty available as
part of Gemini Lamp and Ballast
Systems.
All Hatch Compact & Linear Fluorescent Ballasts Feature:
w
w
w
.
h
a
t
c
h
l
i
g
h
t
i
n
g
.
c
o
m
1
Fluorescent Ballast Catalog 2011_Rev2.0.indd 2 11/8/11 12:49 PM
Table of Contents
Intro: Fluorescent Ballasts
Table of Contents
Part Number Guide
Gemini Lamp & Ballast Systems &
Legacy Series Ballasts
About Hatch Linear & Compact
Fluorescent Ballasts
Compact Fluorescent Smart Kit
Linear Fluorescent Lamps
Lamp & Ballast Pairing Guide
Installation & Testing Guidelines
About Hatch
Compact Fluorescent Ballast Specifcations
Compact Fluorescent Wiring Diagrams &
Case Styles
Linear Fluorescent Ballast Specifcations
Linear Fluorescent Wiring Diagrams &
Case Styles
1
2
4
5
3
1
3
3
5
3
6
3
7
3
8
Product Index & Dimensions
3
3
-
3
4
6
-
1
2
1
4
1
5
-
3
0
3
1
-
3
2
2 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
To view complete online Fluorescent
ballast specifcations, scan this
barcode with your Smartphone.
Dont have a scanning App? Search the Apple App Store,
Android Market or BlackBerry App World for a barcode
scanning application
Fluorescent Ballast Catalog 2011_Rev2.0.indd 3 11/8/11 12:49 PM
The Highest Quality, Most Reliable Fluorescent
Ballasts in the Industry
A
b
o
u
t

H
a
t
c
h

F
l
u
o
r
e
s
c
e
n
t

B
a
l
l
a
s
t
s
The Highest Quality, Most Reliable Fluorescent
Ballasts in the Industry
Industry standard, low profle cases to ft in a wide variety of fxtures.
Wide range of universal input voltage and dedicated input voltage models.
Optimized circuitry to extend lamp life and maximize lamp effciency.
High effciency and high output models available.
Low, normal and high ballast factor models.
Programmed Start, Rapid Start and Instant Start models.
18 foot standard remote mounting on most ballasts.
UL 935 Listed for Hazardous location installations.
Integrated End-Of-Life protection circuitry.
Five year limited warranty offered on all NEMA Premium and Programmed
Start models.
Three year limited warranty offered on all other models.
Available with matched fuorescent lamps and extended warranties as part
of Gemini lamp and ballast systems.
Certifcations
Certifcations
3
Note: Please refer to individual specifcation sheets for applicable certifcations.
Not all ballasts meet all certifcation standards.
Fluorescent Ballast Catalog 2011_Rev2.0.indd 4 11/8/11 12:49 PM
Understanding Hatch Fluorescent Ballast Part Numbers
Example Part Number: HL224HOPS/UV/W
4 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Part Number Guide
HL 2 24 HO PS UV W
B
a
l
l
a
s
t

T
y
p
e
H
L

-
L
in
e
a
r
F
lu
o
r
e
s
c
e
n
t
H
C
-
C
o
m
p
a
c
t
F
lu
o
r
e
s
c
e
n
t
N
u
m
b
e
r

o
f

L
a
m
p
s
1

-
1
L
a
m
p
2

-
1
o
r
2
L
a
m
p
s
3

-
2
o
r
3
L
a
m
p
s
4

-
3
o
r
4
L
a
m
p
s
V
o
l
t
a
g
e
1
2

-
1
2
0
V
o
lt
s
2
7

-
2
7
7
V
o
lt
s
3
4

-
3
4
7
V
o
lt
s
U
V
-
U
n
iv
e
r
s
a
l V
o
lt
a
g
e
1
2
0
-
2
7
7
V
L
a
m
p

W
a
t
t
a
g
e
1
3
W
a
t
t
s

4
0
W
a
t
t
s
1
8
W
a
t
t
s

4
2
W
a
t
t
s
2
4
W
a
t
t
s

5
4
W
a
t
t
s
2
6
W
a
t
t
s

5
5
W
a
t
t
s
2
8
W
a
t
t
s

5
9
W
a
t
t
s
3
2
W
a
t
t
s

7
5
W
a
t
t
s
3
9
W
a
t
t
s

9
6
W
a
t
t
s
S
t
a
r
t
i
n
g

M
e
t
h
o
d
IS

-
In
s
t
a
n
t
S
t
a
r
t
R
S
-
R
a
p
id
S
t
a
r
t
P
S
-
P
r
o
g
r
a
m
m
e
d
S
t
a
r
t
C
a
s
e

S
t
y
l
e
W

-
S
id
e
L
e
a
d
w
/
W
ir
e
s
&
F
e
e
t
W
J
-
B
o
t
t
o
m
L
e
a
d
s
w
/
W
ir
e
s
, F
e
e
t
&
S
t
u
d
s
D

-
D
u
a
l W
a
y
T
e
r
m
in
a
ls
w
/
F
e
e
t
D
J

-
D
u
a
l W
a
y
T
e
r
m
in
a
ls
w
/
F
e
e
t
&
S
t
u
d
s
S

-
S
id
e
P
u
s
h
T
e
r
m
in
a
ls
w
it
h
F
e
e
t

(S
lim
C
a
s
e
)
S
p
e
c
i
a
l

F
e
a
t
u
r
e
s
N
o
M
a
r
k
in
g
-
S
t
a
n
d
a
r
d
B
a
lla
s
t
H
O
-

F
o
r
H
ig
h
O
u
t
p
u
t
L
a
m
p
s
H
E
-

F
o
r
H
ig
h
E
f
f
c
ie
n
c
y
L
a
m
p
s
H
P
-

H
ig
h
P
o
w
e
r
F
a
c
t
o
r
A

-

L
o
w
B
a
lla
s
t
F
a
c
t
o
r
B

-

N
o
r
m
a
l B
a
lla
s
t
F
a
c
t
o
r
C

-

H
ig
h
B
a
lla
s
t
F
a
c
t
o
r
R

-

F
o
r
R
e
s
id
e
n
t
ia
l U
s
e
About This Catalog
This catalog includes our linear and compact fuorescent ballasts organized by the most
popular lamp type that they drive. It is not a complete listing of all compatible lamps. For
complete lamp compatibility charts and electronic specifcations please visit our website
where you can fnd individual data sheets for each ballast.
About This Catalog
www.HatchLighting.com
Fluorescent Ballast Catalog 2011_Rev2.0.indd 5 11/8/11 12:49 PM
Gemini Lamp and Ballast Systems
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 5
With Hatch Gemini Systems you can now purchase pre-packaged linear fuorescent lamps and ballasts. Hatch
ballasts and fuorescent lamps have been paired, tested and approved by Hatch laboratories to operate
optimally together. Please refer to the Lamp and Ballast Pairing Guide (Page 36) to fnd all qualifying Lamp
and Ballast packages. Hatch Gemini Systems offer several notable advantages:
Extended warranty on all lamps purchased as a Gemini Lamp and Ballast System.
(Lamp warranty extensions vary. Please contact Hatch or visit our website for more information.)
5-Year limited warranty on all ballasts purchased as part of a Gemini Lamp and Ballast Systems.
Ballasts and lamps are pre-tested to operate optimally together and are Hatch laboratory approved.
One stop shopping for ballasts and lamp replacements.
Ballast specifcations marked with the symbol are compatible with Gemini Lamp and
Ballast Systems.
Note: In order to qualify for Hatch Gemini warranty benefts and support, you must fll out the Hatch Gemini
Systems Registration Form and return a signed copy to Hatch Headquarters. The form may be downloaded at
www.HatchLighting.com/product-catalog/gemini or acquired by contacting Hatch customer service.
Save time, money and energy purchasing Hatch Gemini Lamp and Ballasts Systems
GEMINI
Lamp and Ballast. Perfectly Matched.
GEMINI
Lamp and Ballast. Perfectly Matched.
Legacy Series Compact Fluorescent Ballasts
Legacy Series Fluorescent Ballasts
Since 1985 Hatch has developed several fuorescent ballasts with unique designs that have become the
industry standard in several lighting fxtures that are still sold and produced today. While these ballasts are no
longer part of our current product catalog, we continue to sell and support several of our Legacy Series
models. Hatch Legacy Series fuorescent ballasts beginning with FR and HR are available as replacement
parts or in large quantities by special order. All FR and HR Series Ballasts are available in 120V, 230V & 277V
confgurations
FR-Series Compact
Fluorescent Ballasts
FR1000LH
FR1000L
FR1300LH
FR1300L
FR1800LH
FR1800L
FR2100LH
FR2100L
FR2600LH
FR2600L
FR3200LH
FR3200L
FR3800LH
FR3800L
HR-Series Compact
Fluorescent Ballasts
HR1000
HR1000 BF
HR1300
HR1300 BF
HR1800
HR1800 BF
HR2100
HR2100 BF
HR2600
HR2600 BF
HR3200
HR3200 BF
HR3800
HR3800 BF
HR4200
HR4200 BF
Full electronic specifcations for all
Legacy Series Fluorescent Ballasts can be found on our website.
Full electronic specifcations for all
Legacy Series Fluorescent Ballasts can be found on our website.
Fluorescent Ballast Catalog 2011_Rev2.0.indd 6 11/8/11 12:49 PM
Quad & Triple Lamps
6 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
CFQ13W/G24q
1 120
HC113RS/12
W
I
15.0 0.25 0.50 1.46 0.9 6.33 150
RS
WJ
HC113RS/HP/12
W
14 0.12 0.95
<1.7
1.0 7.14 30
WJ
2
120
HC213PS/UV
D
II
29
0.25
0.99
1.0
3.45
10
PS
277 0.11
1
120
DJ 16
0.16
0.96 6.25
12
277 0.06
2
120 HC213RS/12
DJ
26 0.38
>0.05
0.88
3.38
150
RS
W
III
1.0
1 WJ 16 0.26 6.25
2
120 HC213RS/HP/12 DJ
II
30.0 0.250 0.99 1.48 1.0 3.33 10
1 18.5 0.155 0.98 1.58 1.2 6.49 12
2
347 HC213PS/34
D 30 0.08 0.98
<1.7
1.03 3.43 10
PS
1 DJ 16 0.05 0.95 1.09 6.81 15
CFTR13W/GX24q
1 120 HC113RS/HP/12
W
I 14 0.12 0.95
<1.7
1.0 7.14 30 RS
WJ
2
120
HC213PS/UV
D
II
29
0.25
0.99
1.0
3.45 10
PS
277 0.11
1
120
DJ 16
0.16
0.96 6.25 12
277 0.06
2
120 HC213RS/12
DJ
26 0.38
>0.05
0.88
3.38
150
RS
W
III
1.0
1 WJ 16 0.26 6.25
2 120
HC213RS/HP/12 DJ
II
30.0 0.250 0.99 1.48 1.0 3.33 10
1 120 18.5 0.155 0.98 1.58 1.2 6.49 12
2
347 HC213PS/34
D 30 0.08 0.98
<1.7
1.03 3.43 10
PS
1 DJ 16 0.05 0.95 1.09 6.81 15
Electronic Compact
Fluorescent Ballasts
13
Watt
Notes: *Case Style: Approvals: Ballast Replacement Kits:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A

HC213PS/UV/D
HC218PS/UV/D
HC226PS/UV/D
HC242PS/UV/D
These Models Are Available In
Ballast Replacement Kits
See Page 13 for
More Information
- Sound Rated: A
- Minimum Starting Temperature: -18C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
Add following suffx for complete part number:
D - Dual way Input/Output connectors
DJ - Dual way Input/Output connectors with studs
W - Wire lead
WJ - Wire lead with studs
13 Watt
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
SMART
KIT

Case Styles and Wire Diagrams can be found on Pg. 14


Dimensions can be found on Pg. 33
Fluorescent Ballast Catalog 2011_Rev2.0.indd 7 11/8/11 12:49 PM
Quad & Triple Lamps
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 7
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A

- Sound Rated: A
- Minimum Starting Temperature: -18C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
Add following suffx for complete part number:
D - Dual way Input/Output connectors
DJ - Dual way Input/Output connectors with studs
W - Wire lead
WJ - Wire lead with studs
CFQ18W/G24q2 1 120 HC118RS/12
W
I 20 0.31 0.53 1.49 1.0 5.00 150 RS
WJ
CFQ18W/G24q
1 120 HC118RS/HP/12
W
I 19 0.16 0.95
<1.7
0.92 4.84 30 RS
WJ
1
120
HC213PS/UV
D
II
20
0.17 0.99
1.0 5.00
10
PS
277 DJ 0.07 0.97 12
1 120 HC213RS/12
DJ
16 0.26 >0.05 0.82 5.13 150 W
III
WJ
1 120 HC213RS/HP/12 DJ
II
20 0.165 0.99 1.57 1.0 5.00 12 RS
1 347 HC213PS/34
D
18 0.06 0.96
<1.7
0.89 4.94 12
PS
DJ
2
120
HC218PS/UV
D 35
0.30
0.99 0.95 2.71
10 277 0.13
1
120
DJ 19
0.16
0.97 1.0 5.26
12
277 0.07
2 120 HC218RS/12
DJ
35.5 0.53 >0.5 0.88 2.48 150
RS
W
III
WJ
2
120 HC218RS/HP/12 DJ
II
43 0.36
0.99
1.0 2.33 10
1 25 0.21 1.25 5.00 12
2
347 HC218PS/34
D 39 0.10 0.98 0.96 2.46 10
PS
1 DJ 21 0.06 0.95 1.03 4.90 15
CFTR18W/GX24q
1 120 HC118RS/HP/12
W
I 19 0.16 0.95
<1.7
0.92 4.84 30 RS
WJ
1
120
HC213PS/UV
D
II
20
0.17 0.99
1.0 5.00
10
PS
277 DJ 0.07 0.97 12
1 120 HC213RS/12
DJ
16 0.26 >0.05 0.82 5.13 150
RS
W
III
WJ
1 120 HC213RS/HP/12 DJ
II
20 0.165 0.99 1.57 1.0 5.00 12
1 347 HC213PS/34
D
18 0.06 0.96
<1.7
0.89 4.94 12
PS
DJ
2
120
HC218PS/UV
D 39
0.33
0.99
1.05
2.69 10
277 0.14
1
120
DJ 20
0.17
0.97 5.25 12
277 0.08
1 120 HC218RS/12
DJ
23 0.37 >0.5 1.10 4.78 150
RS
W
III
WJ
2
120 HC218RS/HP/12 DJ
II
43 0.36
0.99
1.53 1.0 2.33 10
1 25 0.21 1.60 1.25 5.00 12
2
347 HC218PS/34
D 39 0.11 0.98
<1.7
0.96 2.46 10
PS
1 DJ 21 0.06 0.95 1.03 4.90 15
Electronic Compact
Fluorescent Ballasts
18
Watt
18 Watt
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD
%
Starting
Method
Ballast Replacement Kits:
HC213PS/UV/D
HC218PS/UV/D
HC226PS/UV/D
HC242PS/UV/D
These Models Are Available In
Ballast Replacement Kits
See Page 13 for
More Information
SMART
KIT

Case Styles and Wire Diagrams can be found on Pg. 14


Dimensions can be found on Pg. 33
Fluorescent Ballast Catalog 2011_Rev2.0.indd 8 11/8/11 12:49 PM
Quad & Long Lamps
8 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
FT18W/2G11
2
120
HC226PS/UV
D
V 36
0.30 0.99
<1.7 0.93 2.58
10
PS
277 DJ 0.13 0.97 12
2 120 HC226RS/12
DJ
II 38 0.57 >0.5
<1.7
0.95 2.50 150 RS W
WJ
2 347 HC226PS/34
D
II 32 0.10 0.94 0.79 2.46 15 PS
DJ
Electronic Compact
Fluorescent Ballasts
18 - 26
Watt
FT24W/2G11
1 120 HL139RS/12 W 29 0.43 >0.5 <1.7 1.01 3.48 135 RS
2
120
HL224HO/PS/UV
S II
52
0.44
0.98
<1.7
1.00 1.92
10
PS
277 0.19
1
120
27
0.23
1.02 3.78
277 0.10
2
120
W IV
51 0.42 0.99 0.91 1.78
277 50 0.19 0.98
0.92
1.84
1
120
27
0.22 0.99 3.41
277 0.11 0.96 0.94 3.48 12
2
120
HC226PS/UV
D
V
48
0.41
0.99
0.93
1.94
10
PS
277 0.18
1
120
DJ
26 0.21 3.58
277 27 0.10 0.96 3.44 12
2 120 HC226RS/12
DJ
II 48 0.70 >0.5 0.90 1.88 150 RS W
WJ
2
120
HC242PS/UV
D
II
54
0.45 0.99
1.0
1.85
10
PS
277 0.20 0.97 12
1
120
DJ
27 0.22 0.99 3.70 10
277 28 0.11 0.92 3.57 15
2
347 HC226PS/34
D 48 0.14 0.97 0.89 1.85
12
1 DJ 25 0.08 0.92 0.92 3.68
2
120
HL239HO/PS/UV
S II
54
0.46
0.98 1.10 2.04
10
277 0.20
1
120
29
0.24
0.95 1.12 3.86
277 0.12
2
120
W IV
54 0.45 0.99
0.99
1.83
277 55 0.20 0.98 1.80
1
120
30
0.25 0.99
1.09 3.63
277 0.12 0.95 15
18 Watt
24 Watt
26 Watt
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A

- Sound Rated: A
- Minimum Starting Temperature: -18C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
Add following suffx for complete part number:
D - Dual way Input/Output connectors
DJ - Dual way Input/Output connectors with studs
W - Wire lead
WJ - Wire lead with studs
Ballast Replacement Kits:
HC213PS/UV/D
HC218PS/UV/D
HC226PS/UV/D
HC242PS/UV/D
These Models Are Available In
Ballast Replacement Kits
See Page 13 for
More Information
SMART
KIT

CFQ26W/G24q
1 120 HC126RS/HP/12
W
I
25 0.22 0.95
<1.7
0.95 3.80 30
RS
WJ
1 120 HC126RS/12
W
24 0.40 0.54 0.90 3.75 150
WJ
1 120 HC142RS/12
W
30 0.45 0.55 1.59 1.10 3.67 150
WJ
1
120
HC218PS/UV
D
II 28
0.24 0.99
<1.7 1.0 3.57
10
PS
277 DJ 0.10 0.96 12
Case Styles and Wire Diagrams can be found on Pg. 14
Dimensions can be found on Pg. 33
Fluorescent Ballast Catalog 2011_Rev2.0.indd 9 11/8/11 12:50 PM
Quad & Triple Lamps
9 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Electronic Compact
Fluorescent Ballasts
26
Watt
CFQ26W/G24q
1 120 HC218RS/12
DJ II
25.5 0.40 >0.5 <1.7 0.88 3.45 150
RS
W
III
WJ
1 120 HC218RS/HP/12 DJ II 28 0.24 0.99 1.56 1.0 3.57 12
1 347 HC218PS/34
D
II 24 0.07 0.96
<1.7
0.82 3.41 12
PS
DJ
2
120
HC226PS/UV
D
V
51
0.43
0.99
1.00
1.96
10
277 0.19
1
120
DJ 27
0.23
0.98 3.70
277 0.10
2
120 HC226RS/12
DJ II
53 0.76 >0.5 0.99 1.87 150
RS
W
III
1
WJ
2
120 HC226RS/HP/12
DJ
II
53 0.45
0.99
1.57 0.95 1.79 10
1 D 33 0.27 1.58 1.10 3.33 12
2
347 HC226PS/34
D 54 0.16 0.96
<1.7
0.92
1.70 12
PS
1 DJ 27 0.08 0.92 3.40 15
2
120
HC242PS/UV
DJ 54
0.45 0.99
0.90 1.67
10
277 0.21 0.97 12
1
120
D 32
0.27 0.99
1.00 3.13
10
277 0.13 0.95 15
CFTR26W/GX24q
1 120 HC126RS/HP/12
W
I
24 0.21 0.95 <1.7 0.88
3.67
30
RS
WJ
1 120 HC142RS/12
W
30 0.45 0.55 1.59 1.10 150
WJ
1
120
HC218PS/UV
D
II
28
0.24 0.99
<1.7
1.0 3.57
10
PS
277 DJ 0.10 0.96 12
1 120 HC218RS/12
DJ
25.5 0.40 >0.5 0.88 3.45 150
RS
W
III
WJ
1 120 HC218RS/HP/12 DJ II 28 0.24 0.99 1.56 1.0 3.57 12
1 347 HC218PS/34
D
II
24 0.07 0.96
<1.7
0.82 3.41 12
PS
DJ
2
120
HC226PS/UV
D 54
0.45
0.99 1.00 1.85
10
277 0.20
1
120
DJ 29
0.24
0.98 1.10 3.79
277 0.11
2
120 HC226RS/12
DJ
53 0.76
>0.5
0.99 1.87
150
RS
W
III
1 33 0.51 1.20 3.64
WJ
2 120
HC226RS/HP/12
DJ
II
53 0.45
0.99
1.57 0.95 1.79 10
1 120 D 33 0.27 1.58 1.10 3.33 12
2
347 HC226PS/34
D 54 0.16 0.96
<1.7 0.92
1.70 12
PS
1 DJ 27 0.09 0.91 3.40 15
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A

- Sound Rated: A
- Minimum Starting Temperature: -18C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B)
Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
Add following suffx for complete part number:
D - Dual way Input/Output connectors
DJ - Dual way Input/Output connectors with studs
W - Wire lead
WJ - Wire lead with studs
26 Watt
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
Ballast Replacement Kits:
HC213PS/UV/D
HC218PS/UV/D
HC226PS/UV/D
HC242PS/UV/D
These Models Are Available In
Ballast Replacement Kits
See Page 13 for
More Information
SMART
KIT

Case Styles and Wire Diagrams can be found on Pg. 14


Dimensions can be found on Pg. 33
Fluorescent Ballast Catalog 2011_Rev2.0.indd 10 11/8/11 12:50 PM
10
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Triple & Long Lamps
Electronic Compact
Fluorescent Ballasts
26 - 36
Watt
CFTR26W/GX24q
2
120
HC242PS/UV
DJ
II
54
0.45 0.99
<1.7
0.90 1.67
10
PS
277 0.21 0.97 12
1
120
D 32
0.27 0.99
1.00 3.13
10
277 0.13 0.95 15
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A

- Sound Rated: A
- Minimum Starting Temperature: -18C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
Add following suffx for complete part number:
D - Dual way Input/Output connectors
DJ - Dual way Input/Output connectors with studs
W - Wire lead
WJ - Wire lead with studs
26 Watt
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
Ballast Replacement Kits:
HC213PS/UV/D
HC218PS/UV/D
HC226PS/UV/D
HC242PS/UV/D
These Models Are Available In
Ballast Replacement Kits
See Page 13 for
More Information
SMART
KIT

CFTR32W/GX24q
1 120 HC142RS/12
W
I 36 0.53 0.57 1.52 1.00 2.78 150 RS
WJ
1
120
HC226PS/UV
D
V 36
0.31
0.98 <1.7 0.98 2.72 10 PS
277 DJ 0.13
1 120 HC226RS/12
DJ II
40 0.61 >0.5 <1.7 1.10 2.75 150 RS W
III
WJ
1 120 HC226RS/HP/12
DJ
II
41 0.35 0.99 1.53 1.2 2.93 10 RS
D
1 347 HC226PS/34
D
35 0.11 0.95 <1.7 0.72 2.05 12 PS
DJ
2
120
HC242PS/UV
D
II
63
0.53 0.99
<1.7
0.95 1.51
10
PS
277 0.23 0.98
1
120
DJ 42
0.35 0.99
0.96 2.29
277 0.13 0.96 12
32 Watt
FT36W/2G11
1 120 HL139RS/12 W 32 0.46 >0.5
<1.7
0.92 2.87 130 RS
1
120
HC226PS/UV
D
V 32
0.26 0.99
0.82 2.56
10
PS
277 DJ 0.12 0.97 12
1 347 HC226PS/34
D
II
30 0.09 0.94 0.74 2.46 15
DJ
2
120
HC242PS/UV
D
66 0.55 0.99
0.80
1.21
10 277 65 0.24 0.98 1.23
1
120
DJ 37
0.31 0.99
0.88 2.38
277 0.14 0.95 15
1
120
HL224HO/PS/UV
S II 34
0.29
0.98 0.90 2.65
10 277 0.13
1
120
W IV 31
0.26 0.99 0.77 2.48
277 0.12 0.97 0.78 2.52 12
2
120
HL239HO/PS/UV
S II
69
0.59 0.94
1.10 2.04 10
277 0.25 0.98
1
120
36
0.30
0.95 1.12 3.86 20
277 0.20
2
120
W IV
72 0.60 0.99
0.87
1.20
10
277 71 0.26 0.98 1.22
1
120
38
0.32
0.99 0.92 2.42
277 0.14
FT36W/2G11
2
120
HL254HO/PS/UV
S II
89
0.75
0.98
<1.7
1.20
1.35
10
PS
277 0.32 1.40
1
120
46
0.39
0.96 1.22 2.65 20
277 0.18
2
120
W IV
79
0.66 0.98
0.99 1.26
10
277 0.29 0.97 12
1
120
41
0.34 0.98
0.97 2.37
10
277 0.16 0.95 15
36 Watt
Case Styles and Wire Diagrams can be found on Pg. 14
Dimensions can be found on Pg. 33
Fluorescent Ballast Catalog 2011_Rev2.0.indd 11 11/8/11 12:50 PM
11 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Triple & Long Lamps
Electronic Compact
Fluorescent Ballasts
36 - 42
Watt
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
- Sound Rated: A
- Minimum Starting Temperature: -18C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B)
Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
Add following suffx for complete part number:
D - Dual way Input/Output connectors
DJ - Dual way Input/Output connectors with studs
W - Wire lead
WJ - Wire lead with studs
FT39W/2G11
1
120
HC226PS/UV
D
V
42 0.35 0.99
<1.7
0.90
2.14
10
PS
277 DJ 41 0.15 0.98 2.20
1 347 HC226PS/34
D
II
42 0.13 0.96 0.95 2.26 12
DJ
2
120
HC242PS/UV
D 82
0.69 0.99
0.95 1.16
10 277 0.30 0.98
1
120
DJ 45
0.37 0.99
1.00 2.22
277 0.17 0.96 15
40 Watt
42 Watt
39 Watt
36 Watt
FT40W/2G11
1 120 HL139RS/12 W 38 0.53 >0.5 <1.7 0.89 2.34 120
RS
1 120 HC142RS/12
W
I 38.5 0.55 0.58 1.53 0.88 2.29 150
WJ
1
120
HC226PS/UV
D
V 44
0.36 0.99
<1.7
0.90 2.05 10
PS
277 DJ 0.16 0.98
2
120
HC242PS/UV
D
II
82
0.69 0.99
0.95 1.16
10 277 0.30 0.98
1
120
DJ 45
0.37 0.99
1.00 2.22
277 0.17 0.96 12
1 347 HC226PS/34
D
43 0.13 0.95 0.95 2.20 15
DJ
1
120
HL224HO/PS/UV
S 47
0.40
0.98
1.7
1.00 2.13
10 PS
277 0.17
1
120
W IV 45
0.38 0.99 1.01 2.24
277 0.16 0.98 1.02 2.27
1
120
HL239HO/PS/UV
S II
50
0.42
0.98
1.7
1.10 2.20
10
PS
277 0.19
1
120
W IV
0.42 0.99
1.09 2.18
277 0.19 0.97 12
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
Ballast Replacement Kits:
HC213PS/UV/D
HC218PS/UV/D
HC226PS/UV/D
HC242PS/UV/D
These Models Are Available In
Ballast Replacement Kits
See Page 13 for
More Information
SMART
KIT

FT36W/2G11
4
120
HL454HO/PS/UV
S XI
160
1.35 0.99
<1.7 1.10
0.69
10
PS
277 0.59 0.98
3
120
122
1.03 0.99
0.90
277 0.46 0.97 12
2
120
80
0.66 0.99
1.38
10
277 0.31 0.94 15
1
120
42
0.35 0.98
2.62
10
277 0.18 0.85 15
4
120
W XV
154 1.33 0.99
<1.7
0.86 0.56
10
277 152 0.57 0.97 0.87 0.57
3
120
114
0.98 0.99
0.88 0.77
277 0.43 0.96
2
120 74 0.63 0.99 0.86
1.16
277 75 0.29 0.94 0.87
1
120 39 0.33 0.98
0.88
2.26
15
277 41 0.17 0.85 2.15
CFTR42W/GX24q
1 120 HC142RS/12
W
I 42.5 0.61 0.58 1.51 0.88 2.07 150 RS
WJ
1
120
HC226PS/UV
D
V 46
0.38
0.98 <1.7 0.98 2.13 10 PS
277 DJ 0.17
1 120 HC226RS/12
DJ II
43 0.63 >0.5 <1.7 0.91 2.12 150
RS
W
III
WJ
1 120 HC226RS/HP/12
D
II 49 0.42 0.99 1.48 1.1 2.24 10
DJ
Case Styles and Wire Diagrams can be found on Pg. 14
Dimensions can be found on Pg. 33
Fluorescent Ballast Catalog 2011_Rev2.0.indd 12 11/8/11 12:50 PM
12 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Quad, Triple & Long Lamps
Electronic Compact
Fluorescent Ballasts
42 - 70
Watt
CFTR42W/GX24q
1 347 HC226PS/34
D
II
0.15 0.97
<1.7
1.03 2.10 12
PS
DJ
2
120
HC242PS/UV
D
94 0.77 0.99
1.0
1.06
10 277 93 0.38 0.98 1.08
1
120
DJ 47
0.40 0.99
2.13
277 0.18 0.96 12
42 Watt
55 Watt
CFTR57W/GX24q
1
120
HC226PS/UV
D
V
54 0.45 0.99
<1.7
0.88
1.63
10
PS
277 DJ 53 0.19 0.98 1.66
1
120
HC242PS/UV
D
II
58
0.49 0.99
1.0 1.72
277 DJ 0.22 0.97
12
1 347 HC226PS/34
D
60 0.18 0.96 0.93 1.55
DJ
CFQ57W/G24q
1
120
HC226PS/UV
D
V
59 0.49
0.99
<1.7
0.88
1.49
10
PS
277 DJ 56 0.20 1.57
1 347 HC226PS/34
D
II 60 0.18 0.96 0.93 1.55 12
DJ
CFQ57W/GX24q 1 120 HC226RS/12
DJ II
55 0.78 >0.5 <1.7 0.88 1.60 150 RS W
III
WJ
CFTR70W/GX24q 1
120
HC242PS/UV
D
II 73
0.61 0.99
<1.7 1.0 1.37
10
PS
277 DJ 0.27 0.97 12
57 Watt
70 Watt
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input Cur-
rent (Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
FT55W/2G11
1 120 HC155RS/12
W
I 52 0.74 >0.5
<1.7
0.90 1.73 <120 RS
WJ
1
120
HC242PS/UV
D
II 44
0.37 0.99
0.70 1.59
10
PS
277 DJ 0.17 0.96 12
2
120
HL254HO/PS/UV
S II
112 0.94
0.98 0.90
0.80
10
277 109 0.41 0.83
1
120
58
0.49
0.96 0.92 1.59 15
277 0.22
2
120
W IV
112 0.94
0.98 0.90
0.80
10
277 109 0.41 0.83
1
120
58
0.49
0.96 0.92 1.59 15
277 0.22
4
120
HL454HO/PS/UV
S XI
202
1.70 0.99
0.85 0.42
10
277 0.77 0.98
3
120
153
1.28
0.99
0.87 0.57
277 0.56
2
120 101 0.85
0.85
0.84
277 102 0.39 0.96 0.83 12
1
120
53
0.45 0.99
0.87 1.64
10
277 0.22 0.90 15
4
120
W XV
209 1.74 0.99
0.95
0.44
10 277 207 0.76 0.98
3
120 155 1.29 0.99
0.96 0.58
277 0.57 0.97 12
2
120 101 0.84 0.99
0.97
0.89 10
277 0.38 0.94 0.88 15
1
120 54 0.46 0.99
1.05
1.78 10
277 56 0.22 0.86 1.72 15
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A

- Sound Rated: A
- Minimum Starting Temperature: -18C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B)
Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
Add following suffx for complete part number:
D - Dual way Input/Output connectors
DJ - Dual way Input/Output connectors with studs
W - Wire lead
WJ - Wire lead with studs
Ballast Replacement Kits:
HC213PS/UV/D
HC218PS/UV/D
HC226PS/UV/D
HC242PS/UV/D
These Models Are Available In
Ballast Replacement Kits
See Page 13 for
More Information
SMART
KIT

Case Styles and Wire Diagrams can be found on Pg. 14


Dimensions can be found on Pg. 33
Fluorescent Ballast Catalog 2011_Rev2.0.indd 13 11/8/11 12:50 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 13
Compact Fluorescent Smart Kits
Smart Kit Cross Reference
Hatch Compact Fluorescent Smart Kits are designed to make
ballast replacement simple and easy. Smart Kits are available
with 13 Watt, 18 Watt, 26 Watt & 42 Watt ballasts.
Hatch Smart Kit Universal Advance Osram Robertson GE Keystone
HC213PS/UV/K
C213UNVSE000K/
BE/BES
ICF-2S13-H1-LD QTP 1/2x13CF/UNV
PSM213C-
QMV
GEC213-MVPS-SE
GEC213-MVPS-BES
KTEB-213-UV-TP-
PSD
HC218PS/UV/K
C218UNVSE/BE/
BES
ICF-2S18-H1-LD
REL-2Q18
VEL-2Q18
R-2Q18-4P-TP
V-2Q18-4P-TP
QTP 1/2x18CF/UNV
PSM218C-
QMV
GEC218-MVPS-SE
GEC218-MVPS-BES
KTEB-218-UV-TP-
PSD
HC226PS/UV/K
C2642UNVSE/BE/
BES
C132SR120BE
C132SR277BE
C266SR120BE
C226SR277BE
ICF-2S26-H1-LD
REL-1T32
VEL-1T32
REL-1T42
VEL-1T42
QTP
1X26/32/42CF/UNV
QTP 2X26/UNV
QTP 1/2xCF/UNV
PSM226C-
QMV
GEC226-MVPS-SE
GEC226-MVPS-BES
KTEB-226-UV-TP-
PSD
HC242PS/UV/K
C242UNV BE/SE/
BES
ICF-2S42-M2-BS
ICF-2S42-MS-LD
ICF-2S42-MS-LS
PSP242T-
RMVW
C242UNVSE
C242UNVBES
GEC242-MVPS-BES
GEC242-MVPS-SE
KTEB-242T-UV-TP-
PSD
Electronic Universal Programmed Start Ballasts.
Low profle cases to ft most fxtures.
Simple mounting with color coded, bottom and side
push-in connectors.
Integrated End-Of-Lamp life protection.
THD under 10% in most applications.
Maximum case temperature 90C
Wires, wire removal tool & adapter plate with studs for maximum
fexibility.
Mounting plate uses simple crimp tabs to mount to ballast.
There are no small screws or mounting hardware to lose.
Ability to use a single ballast for one or two lamp applications
SMART
KIT

Smart Kit Includes:


Fluorescent Ballast Catalog 2011_Rev2.0.indd 14 11/8/11 12:50 PM
14 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Wire Diagrams & Case Styles
H
W
L
M
1
M
3
H
W
L
M
1
M
3
L
M
1
M
2
W
H
DJ.
D.
WJ.
W.
I. II. III.
Wire lead
B A L L A S T S MU S T B E G R O U N D E D
Wire lead with studs
Dual way Input/Output connectors
Dual way Input/Output connectors
with studs
L
M
1
M
2
W
H
BALLAST
Single Lamp Application
LAMP
WHITE
BLACK
RED
BLUE
BLUE
RED
LINE



BALLAST
Two Lamp Applications
BLACK
BLUE
YELLOW
2 LAMPS
RED
LINE
WHITE
GREEN
WHITE
LINE
BLACK
BALLAST
RED
RED
YELLOW
YELLOW
BLUE
BLUE
A full list of Case Dimensions can be found on Pgs. 33
Fluorescent Ballast Catalog 2011_Rev2.0.indd 15 11/8/11 12:50 PM
15 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
T5 Circleline Lamps
Electronic Linear
Fluorescent Ballasts
22 - 55
Watt
FC9T5
22W
2
120
HL224HO/PS/UV
S II
52
0.44
0.98
<1.7
1.00 1.92
10
PS
277 0.19
1
120
27
0.23
1.02 3.78
277 0.10
2
120
W IV
54
0.45 0.99 1.10 2.04
277 0.20 0.98
1.11
2.06
1
120
27
0.23 0.99 4.11
277 0.10 0.96 1.13 4.19 12
2
120
HL239HO/PS/UV
S II
54
0.46
0.98 1.10 2.04 10
277 0.20
1
120
29
0.24 0.95
1.12 3.86 15
277 0.12 0.98
2
120
W IV
63
0.53 0.99
1.25 1.98
10 277 0.23 0.98
1
120
33
0.28 0.99
1.31 3.97
277 0.13 0.95 12
(1) FC9T5 +
(1) FC12T5
2
120
HL239HO/PS/UV
S II
68
0.58
0.98
<1.7
1.00 1.47
10 PS
277 0.25
120
W IV
0.57 0.99
0.96 1.41
277 0.25 0.98
FC8T9 22W 1 120 HC1C3032RS/12 W 27 0.40 0.54 1.64 1.14 4.22 150 RS
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
FC12T5
40W
1
120
HL224HO/PS/UV
S II 40
0.34
0.98
<1.7
0.84 2.10
10
PS
277 0.15
1
120
W IV 39
0.32 0.99 0.85 2.18
277 0.15
0.98
0.87 2.23
2
120
HL239HO/PS/UV
S II
80
0.68
0.90 1.13
277 0.29
1
120
42
0.35
0.92 2.19 15
277 0.16
2
120
W IV
93 0.78 0.99 1.02
1.09
10 277 92 0.34 0.98 1.01
1
120 49 0.41 0.99 1.07
2.18
277 50 0.19 0.97 1.10 12
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
22 Watt Circleline
32 Watt Circleline
40 Watt Circleline
FC12T5/HO
55W
2
120
HL254HO/PS/UV
S II
106 0.89
0.98
<1.7
0.85
0.80
10
PS
277 103 0.38 0.83
1
120
55
0.46
0.96 0.87 1.58 15
277 0.21
2
120
W IV
104
0.87 0.99
0.85 0.82 10
277 0.39
0.98
1
120
50
0.41
0.81 1.60
12
277 0.19 0.96 15
3
120
HL454HO/PS/UV W XV
136
1.13 0.99
1.5
0.83 0.61
10
277 0.50 0.97 0.84 0.62
2
120
88
0.73 0.99
0.75 0.85
277 0.34 0.97
1
120 46 0.38 0.99
0.77
1.66
15
277 47 0.19 0.96 1.65
55 Watt Circleline
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
FC12T9 32W 1 120 HC1C3032RS/12 W 34 0.53 0.53 1.68 1.0 2.94 150 RS
Fluorescent Ballast Catalog 2011_Rev2.0.indd 16 11/8/11 12:50 PM
16 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
T5 Lamps
Electronic Linear
Fluorescent Ballasts
14 - 28
Watt
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
F21T5/HE
2
120
HL228HE/PS/UV
S II
51
0.42 0.99
<1.7
1.04 2.04 10
PS
277 0.19 0.98
1
120
26
0.22 0.99
1.06 4.08 12
277 0.10 0.95
2
120
W IV
46
0.38 0.99
0.94 2.04
10
277 0.17 0.97 12
1
120 24 0.20 0.99 0.97 4.04 10
277 25 0.10 0.93 1.02 4.08 15
21 Watt
F14T5/HE
2
120
HL228HE/PS/UV
S II
34
0.28 0.99
<1.7
1.04 3.06 12
PS
277 0.13 0.96
1
120
19
0.16 0.98
1.12 5.89 15
277 0.08 0.92
2
120
W IV
30 0.25 0.99 0.92 3.06 10
277 31 0.12 0.96 0.94 3.03 12
1
120
17
0.14 0.99
1.00 5.88
10
277 0.07 0.91 15
14 Watt
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
F28T5/HE
2
120
HL228HE/PS/UV
S II
67
0.56 0.99
<1.7
1.05 1.57 10
PS
277 0.24 0.98
1
120
33
0.28
0.95 1.04 3.15 12
277 0.13
2
120
W IV
67
0.56 0.99
1.05 1.57
10
277 0.24 0.98
1
120
34
0.28 0.99
1.07 3.15
277 0.13 0.96 12
28 Watt
24 Watt High Output
F24T5/HO
1 120 HL139RS/12 W 28 0.41 >0.5
<1.7
1.00 3.57 135 RS
2
120
HL224HO/PS/UV
S II
52
0.44
0.98
1.00 1.92
10
PS
277 0.19
1
120
27
0.23
1.02 3.78
277 0.10
2
120
W IV
52
0.44 0.99 0.94 1.81
277 0.19 0.98 0.95 1.83
1
120
27
0.23 0.99
0.97 3.59
277 0.11
0.98
2
120
HL239HO/PS/UV
S II
55
0.47
1.10 2.00
277 0.21
1
120
29
0.25
1.12 3.86 15
277 0.12
2
120
W IV
59
0.50 0.99
1.08 1.83
10 277 0.22 0.98
1
120
30
0.25 0.99
1.10 3.66
277 0.12 0.95 15
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 17 11/8/11 12:50 PM
17 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
T5 Lamps
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
Electronic Linear
Fluorescent Ballasts
39 - 54
Watt
F39T5/HO
1 120 HL139RS/12 W 35 0.49 >0.5 <1.7 0.88 2.51 120 RS
1
120
HL224HO/PS/UV
S II
39 0.33 0.99
1.7
0.90
2.30
10
PS
277 38 0.14 0.98 2.36
120
W IV 34
0.28 0.99
0.91 2.67
277 0.13 0.97 12
2
120
HL239HO/PS/UV
S II
87 0.73
0.98
<1.7
1.00
1.15
10
277 85 0.31 1.18
1
120
43
0.36
1.02 2.37
277 0.16
2
120
W IV
90 0.78
0.99
1.00
1.11
277 89 0.34 1.12
1
120 46 0.39 1.03 2.23
277 47 0.18 0.97 1.06 2.25 12
39 Watt High Output
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
49 Watt High Output
F54T5/HO/ES
49W
2
120
HL254HO/PS/UV
S II
107 0.90 0.99
<1.7 1.00
0.93
10 PS
277 106 0.39 0.98 0.94
1
120
W IV 57
0.48 0.99
1.75
277 0.21 0.98
4
120
HL454HO/PS/UV
S XI
214 1.80 0.99
0.47
277 213 0.78 0.98
3
120 164 1.38 0.99
0.61
277 163 0.60 0.98
2
120
W XV
107 0.90 0.99 0.93
277 106 0.39 0.98 0.94
1
120
57
0.48 0.99
1.75
277 0.21 0.98
F54T5/HO
2
120
HL254HO/PS/UV
S II
120 1.00
0.98
<1.7
1.00
0.83
10
PS
277 117 0.43 0.85
1
120
62
0.52
0.96 1.02 1.65 15
277 0.23
2
120
W IV
120
1.00 0.99
1.00 0.83
10 277 0.43 0.98
1
120
61
0.51 0.99
1.01 1.65
277 0.23 0.97 12
4
120
HL454HO/PS/UV
S XI
220
1.85
0.99
1.00 0.45
10
277 0.79
3
120
170
1.42
1.02 0.60
277 0.62 0.98
2
120
116
0.98 0.99
1.00 0.86
277 0.44 0.97 12
1
120
63
0.52 0.99
1.02 1.62
10
277 0.25 0.91 15
4
120
W XV
229 1.94 0.99 0.96 0.42
10
277 222 0.83 0.98 0.98 0.44
3
120
171
1.47 0.99 0.97
0.58
277 0.63 0.98 0.99
2
120
112
0.96 0.99 0.96 0.86
277 0.42 0.98 0.98 0.88
1
120 59 0.50 0.99 1.00 1.69
277 60 0.23 0.94 1.01 1.67
54 Watt High Output
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 18 11/8/11 12:50 PM
F17T8
2
120
HL232RIS/12
W
V
34 0.50
0.54
<1.7
0.93 2.74
150 IS
1 25 0.39 1.10 4.40
4
120 HL432RIS/12 IX
56 0.83 0.56 0.74 1.32
3 45 0.70 0.54 0.80 1.78
F17T8
2
347
HL232AIS/34 qv
W
V
29 0.09 0.98
1.5
0.80 2.78 10
IS
1 19 0.06 0.91 0.98 5.17 15
2
120
HL232AIS/UV/HE qv II
29
0.24 0.99
<1.7
0.93 3.20 <10
277 0.11 0.97 0.89 3.06 <12
1
120
19
0.16 0.99 1.17 6.15 <10
277 0.07 0.95 1.11 5.84 <12
2
120
HL232APS/UV/HE v XII
30 0.25 0.99
0.77
2.57 10
PS
277 31 0.12 0.97 2.48 12
1
120
21
0.17 0.99
0.84 4.00
10
277 0.08 0.95 15
3
120
HL332AIS/UV/HE qv VIII
42 0.36 0.99 0.83 1.98 10
IS
277 43 0.16 0.95 0.82 1.91 15
2
120 34 0.28 0.99 0.95 2.79 10
277 35 0.14 0.92 0.94 2.69 15
3
120
HL332APS/UV/HE v XIII
45
0.37 0.99
0.77 1.71
10
PS
277 0.17 0.96 12
2
120 35 0.30 0.99
0.84
2.40 10
277 36 0.14 0.95 2.33 15
4
120
HL432AIS/UV/HE qv IX
56
0.47 0.99
0.81 1.45
10
IS
277 0.20 0.96 12
3
120
47
0.39 0.99
0.90 1.91
10
277 0.17 0.95 15
4
120
HL432APS/UV/HE v X
55 0.46 0.99 0.73 1.34 10
PS
277 56 0.21 0.97 0.74 1.32 12
3
120 48 0.40 0.99 0.81 1.69 10
277 49 0.18 0.96 0.82 1.67 12
F17T8
1
120
HL132BIS/UV/HE qv
W
16
0.13 0.99
<1.7
0.90 5.63 12
IS
277 0.07 0.96
2
120
HL232BIS/UV/HE qv IX
32
0.26 0.99
0.96 3.00
<10
277 0.11 0.98 <12
1
120 21 0.17 0.99
1.31
6.25 <10
277 22 0.08 0.95 5.95 <15
2
120
HL232BPS/UV/HE v XII
34 0.30 0.98
0.90
2.65
10
PS
277 35 0.13 0.96 2.57
1
120 23 0.20 0.98
1.03
4.48
277 24 0.09 0.93 4.29 12
3
120
HL332BIS/UV/HE qv VIII
47 0.39 0.99 0.86
1.83
10
IS
277 48 0.17 0.95 0.88 15
2
120 37 0.31 0.99 1.01 2.73 10
277 38 0.14 0.93 1.03 2.71 15
3
120
HL332BPS/UV/HE v XIII
50 0.42 0.98
0.90
1.80
10
PS
277 51 0.19 0.97 1.77
2
120 40 0.33 0.98
0.98
2.45
277 41 0.15 0.95 2.39 12
4
120
HL432BIS/UV/HE qv IX
62
0.52 0.99
0.90 1.45
10
IS
277 0.22 0.96 12
3
120
51
0.43 0.99
0.99 1.94
10
277 0.18 0.95 15
18 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
T8 Lamps
Electronic Linear
Fluorescent Ballasts
17
Watt
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input Cur-
rent (Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
17 Watt
q v
Low Ballast Factor
Residential
Normal Ballast Factor
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 19 11/8/11 12:50 PM
T8 Lamps
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 19
Electronic Linear
Fluorescent Ballasts
17 & 25
Watt
F17T8
4
120
HL432BPS/UV/HE v W X
63
0.52 0.98
<1.7
0.87 1.39 10
PS
277 0.24 0.97 0.89 1.41 12
3
120
53
0.45 0.98
0.94
1.77 10
277 0.21 0.95 1.78 15
F17T8
2
120
HL232CIS/UV/HE qv
W
V
42
0.35 0.99
<1.7
1.21 2.88 10
IS
277 0.16 0.95 1.24 2.95 15
1
120
28
0.24 0.99
1.40 5.00
10
277 0.11 0.92 15
2
120
HL232CPS/UV/HE v XII
44
0.37 0.99
1.18 2.68
10
PS
277 0.16 0.96 12
1
120
30
0.25 0.99
1.44 4.80
10
277 0.12 0.93 15
3
120
HL332CIS/UV/HE qv VIII
60 0.54 0.99
1.19
1.98 10
IS
277 58 0.24 0.97 2.05 12
2
120 45 0.41 0.99 1.20 2.67 10
277 46 0.19 0.95 1.33 2.89 15
3
120
HL332CPS/UV/HE v XIII
62
0.52 0.99
1.18 1.90
10
PS
277 0.23 0.96 12
2
120
49
0.40 0.99
1.30 2.65
10
277 0.19 0.95 15
17 Watt
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
q v
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
F25T8
25W
2
120
HL232RIS/12
W
V
57 0.65
0.57 <1.7
0.90 1.58
150
IS
1 31 0.47 1.05 3.39
4
120 HL432RIS/12 IX
77 1.10 0.58
<1.7
0.72 0.94
IS
3 63 0.92 0.57 0.79 1.25
F25T8
25W
2
347
HL232AIS/34 qv
W
V
40 0.12 0.99
<1.7
0.76 1.91 10
IS
1 25 0.08 0.97 0.93 3.75 12
2
120
HL232AIS/UV/HE qv II
39
0.33 0.99
0.85 2.17
<10 277 0.14 0.98
1
120
25
0.21 0.99 1.05 4.20
277 0.09 0.97 1.00 4.00 <12
2
120
HL232APS/UV/HE v XII
41
0.35 0.99
0.74 1.80
10
PS
277 0.15 0.98
1
120 27 0.23 0.99
0.88
3.26
277 28 0.10 0.97 3.14 12
3
120
HL332AIS/UV/HE qv VIII
59 0.49 0.99 0.79 1.34 10
IS
277 60 0.22 0.97 0.78 1.30 12
2
120 46 0.39 0.99 0.89 1.94 10
277 47 0.18 0.96 0.88 1.87 12
3
120
HL332APS/UV/HE v XIII
62
0.51 0.99
0.74 1.19
10
PS
277 0.23 0.98
2
120 49 0.40 0.99
0.88
1.80
277 50 0.18 0.97 1.76 12
4
120
HL432AIS/UV/HE qv IX
76 0.63 0.99 0.75
0.99
10
IS
277 77 0.28 0.98 0.76
3
120
63
0.53 0.99 0.82 1.30
277 0.23 0.97 0.84 1.33 12
25 Watt
Normal Ballast Factor
High Ballast Factor
Low Ballast Factor
Residential
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 20 11/8/11 12:50 PM
T8 Lamps
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 20
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
Electronic Linear
Fluorescent Ballasts
25
Watt
25 Watt
q v
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
F25T8
25W
4
120
HL432APS/UV/HE v W X
77 0.65 0.99
<1.7
0.73 0.94
10 PS
277 78 0.29 0.98
3
120 65 0.55 0.99
0.80
1.23
277 66 0.24 0.98 1.22
F25T8
25W
1
120
HL132BIS/UV/HE qv
W
22
0.18 0.99
<1.7
0.89 4.05
10
IS
277 0.08 0.97 12
2
120
HL232BIS/UV/HE qv IX
44
0.37
0.99
0.88 2.00
<10 277 0.16
1
120
28
0.23
1.14 4.07
277 0.10 0.97 <12
2
120
HL232BPS/UV/HE v XII
47
0.40 0.99 0.83 1.77
10
PS
277 0.18 0.95 0.88 1.87
1
120 31 0.26 0.98
1.01
3.26
277 32 0.12 0.95 3.16 12
3
120
HL332BIS/UV/HE qv VIII
72
0.60
0.99
0.95 1.32
10
IS
277 0.26
2
120 54 0.45
1.07
1.98
277 55 0.20 0.96 1.95 12
3
120
HL332BPS/UV/HE v XIII
68 0.58 0.99
0.88
1.29
10
PS
277 69 0.26
0.98
1.28
2
120 53 0.44
0.95
1.79
277 54 0.20 0.97 1.76
4
120
HL432BIS/UV/HE qv IX
83 0.69 0.99 0.82
0.99
IS
277 84 0.30 0.97 0.83 12
3
120 69 0.58 0.99 0.91 1.32 10
277 70 0.25 0.97 0.92 1.31 12
4
120
HL432BPS/UV/HE v X
88
0.74 0.99 0.84 0.96
10
PS
277 0.33
0.98
0.85 0.97
3
120
74
0.62
0.90 1.21
277 0.28 0.97 12
F25T8
25W
2
120
HL232CIS/UV/HE qv
W
V
60
0.51 0.99
<1.7
1.16 1.93 10
IS
277 0.22 0.97 1.18 1.97 12
1
120
39
0.33 0.99 1.47 3.78 10
277 0.15 0.94 1.44 3.68 15
2
120
HL232CPS/UV/HE v XII
60
0.50 0.99
1.15 1.92
10
PS
277 0.22 0.97 12
1
120
38
0.32 0.99
1.33 3.50
10
277 0.14 0.95 15
3
120
HL332CIS/UV/HE qv VIII
83 0.75 0.99
1.16
1.40
10
IS
277 81 0.33 0.98 1.43
2
120 63 0.57 0.99 1.23
1.95
277 64 0.24 0.97 1.25 12
3
120
HL332CPS/UV/HE v XIII
87
0.73 0.99
1.15 1.32
10
PS
277 0.32 0.98
2
120
68
0.57 0.99
1.33 2.00
277 0.25 0.97 12
Low Ballast Factor
Normal Ballast Factor
High Ballast Factor
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 21 11/8/11 12:50 PM
T8 Lamps
21 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Electronic Linear
Fluorescent Ballasts
25
Watt
25 Watt
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
q v
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
F32T8
25W
2
347 HL232AIS/34
W
V
43 0.13 0.99
<1.7
0.82 1.91 10
IS
1 27 0.08 0.97 1.01 3.75 12
2
120
HL232AIS/UV/HE qv
40
0.34 0.99
0.81 2.02
<10 277 0.15 0.98
1
120
26
0.22 0.99
1.03 3.96
277 0.10 0.97 <12
2
120
HL232APS/UV/HE v XII
44
0.37 0.99
0.79 1.80
10
PS
277 0.16 0.98
1
120 28 0.24 0.99
0.92
3.29
277 29 0.11 0.97 3.17 12
3
120
HL332AIS/UV/HE qv VIII
63
0.53
0.99
0.84 1.33
10
IS
277 0.24
2
120
49
0.41
0.98 2.00
277 0.19 0.96 12
3
120
HL332APS/UV/HE v XII
64 0.53 0.99
0.79
1.23
10
PS
277 65 0.24 0.98 1.22
2
120 51 0.42 0.99
0.92
1.80
277 52 0.19 0.97 1.77 12
4
120
HL432AIS/UV/HE qv IX
81 0.68 0.99 0.80
0.99
10
IS
277 82 0.30 0.98 0.81
3
120 67 0.56 0.99 0.89 1.33
277 68 0.25 0.97 0.90 1.32 12
4
120
HL432APS/UV/HE v XII
80 0.67 0.99 0.75
0.94
10 PS
277 81 0.30 0.98 0.76
3
120 67 0.56 0.99 0.81
1.21
277 68 0.25 0.98 0.82
F32T8
25W
1
120
HL132BIS/UV/HE qv
W
23
0.19 0.99
<1.7
0.87 3.78 10
IS
277 0.09 0.98
2
120
HL232BIS/UV/HE qv V
44
0.37
0.99
0.87 1.98
<10
277 0.16
1
120
29
0.23
1.15 3.96
277 0.10 0.98
2
120
HL232BPS/UV/HE v XIII
50
0.42 0.99
0.92 1.84
10
PS
277 0.19 0.97
1
120
33
0.27 0.99
1.05 3.18
277 0.12 0.95 12
3
120
HL332BIS/UV/HE qv VIII
71 0.59 0.99 0.94
1.32
10
IS
277 72 0.26 0.97 0.95 12
2
120
54
0.45 0.99
1.07 1.98
10
277 0.20 0.96 12
2
120
HL332BPS/UV/HE v XIII
72 0.60 0.99
0.90
1.25
10 PS
277 73 0.27 0.98 1.23
1
120 55 0.46 1.00 0.97 1.77
277 56 0.21 0.98 0.98 1.75
Low Ballast Factor
Normal Ballast Factor
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 22 11/8/11 12:50 PM
T8 Lamps
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 22
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
q v
F32T8
25W
4
120
HL432BIS/UV/HE qv
W
IX
94
0.78 0.99
<1.7
0.94 1.00
10
IS
277 0.34 0.98 0.93 0.99
3
120
77
0.64 0.99
1.02 1.32
277 0.28 0.97 12
4
120
HL432BPS/UV/HE v X
93
0.77 0.99
0.89 0.96
10 PS
277 0.34 0.98
3
120
76
0.64 0.99
0.94
1.23
277 0.28 0.98 1.24
F32T8
25W
2
120
HL232CIS/UV/HE qv
W
V
59 0.50 0.99
<1.7
1.18
2.00 10
IS
277 58 0.22 0.97 2.03 12
1
120 38 0.32 0.99
1.40
3.68 10
277 37 0.14 0.95 3.78 15
2
120
HL232CPS/UV/HE v XII
64
0.54 0.99
1.24 1.94
10
PS
277 0.24 0.98
1
120
41
0.34 0.99
1.46 3.56
277 0.16 0.95 12
3
120
HL332CIS/UV/HE qv VIII
87 0.80 0.99
1.18
1.36
10
IS
277 85 0.35 0.98 1.39
2
120
65
0.61 0.99
1.30 2.00
277 0.27 0.98
3
120
HL332CPS/UV/HE v XIII
89
0.75 0.99
1.19 1.34
PS
277 0.33 0.98
2
120
69
0.58 0.99
1.37 1.99
277 0.26 0.97 12
Electronic Linear
Fluorescent Ballasts
25 & 28
Watt
25 Watt
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
F32T8
28W
2
347
HL232AIS/34
W
V
46 0.13 0.99
<1.7
0.78 1.70
10
IS
1 29 0.09 0.98 0.98 3.38
2
120
HL232AIS/UV/HE qv II
44
0.37
0.99
0.79 1.79
<10 277 0.16
1
120
28
0.24 1.02 3.64
277 0.10 0.97 0.99 3.53 <12
2
120
HL232APS/UV/HE v XII
46 0.39 0.99
0.75
1.63
10
PS
277 47 0.17 0.98 1.60
1
120
30
0.25 0.99
0.86 2.87
277 0.11 0.97 12
3
120
HL332AIS/UV/HE qv VIII
67
0.56 0.99
0.79 1.18
10
IS
277 0.26 0.97 12
2
120
51
0.43 0.99
0.91 1.78
10
277 0.20 0.96 12
3
120
HL332APS/UV/HE v XIII
69
0.57 0.99
0.75 1.09
10
PS
277 0.25 0.98
2
120 54 0.45 0.99
0.86
1.59
277 55 0.20 0.97 1.56 12
28 Watt
Normal Ballast Factor
High Ballast Factor
Low Ballast Factor
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 23 11/8/11 12:50 PM
T8 Lamps
23 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Electronic Linear
Fluorescent Ballasts
28
Watt
28 Watt
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
q v
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
F32T8
28W
4
120
HL432AIS/UV/HE qv
W
IX
89
0.74 0.99
<1.7
0.78 0.88
10
IS
277 0.32 0.98
3
120
68
0.57 0.99
0.79 1.16
277 0.27 0.97 12
4
120
HL432APS/UV/HE v X
87 0.73 0.99 0.73 0.84
10 PS
277 88 0.32 0.98 0.75 0.85
3
120 72 0.61 0.99 0.80
1.12
277 73 0.27 0.98 0.82
F32T8
28W
1
120
HL132BIS/UV/HE qv
W
24
0.20 0.98
<1.7
0.87 3.63 10
IS
277 0.19 0.99
2
120
HL232BIS/UV/HE qv V
49
0.41
0.99
0.87 1.78
<10
277 0.18
1
120
31
0.25
1.17 3.79
277 0.11 0.98
2
120
HL232BPS/UV/HE v XII
54
0.45 0.99
0.90 1.67
10
PS
277 0.20 0.98
1
120
35
0.29 0.99
1.06 3.03
277 0.13 0.96
3
120
HL332BIS/UV/HE qv VIII
76 0.63 0.99
0.89
1.17
IS
277 77 0.28 0.97 1.16 12
2
120
57
0.48 0.99
1.01 1.77
10
277 0.21 0.96 12
3
120
HL332BPS/UV/HE v XIII
78 0.65 0.99
0.88
1.13
10
PS
277 79 0.29 0.98 1.11
2
120
61
0.52 0.99
1.00 1.64
277 0.23 0.97
4
120
HL432BIS/UV/HE qv IX
100
0.83 0.99
0.88 0.88
IS
277 0.36 0.98
3
120 83 0.69 0.99 0.98
1.18
277 84 0.30 0.97 0.99 12
4
120
HL432BPS/UV/HE v X
100
0.84 0.99 0.85 0.85
10
PS
277 0.37 0.98 0.86 0.86
3
120
83
0.70 0.99 0.92 1.11
277 0.31 0.97 0.93 1.12 12
F32T8
28W
2
120
HL232CIS/UV/HE qv
W
V
66
0.57
0.97
<1.7
1.21 1.84 10
IS
277 0.25 1.25 1.90 12
1
120
41
0.35 0.99
1.47 3.59
10
277 0.16 0.95 15
2
120
HL232CPS/UV/HE v XII
68
0.57 0.99
1.18 1.74
10
PS
277 0.25 0.98
1
120
43
0.36 0.99
1.39 3.23
277 0.16 0.96 12
Low Ballast Factor
High Ballast Factor
Normal Ballast Factor
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 24 11/8/11 12:50 PM
T8 Lamps
24 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
v
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
Electronic Linear
Fluorescent Ballasts
28 & 30
Watt
q
28 Watt
30 Watt
F32T8
30W
2
347
HL232AIS/34
W
V
47 0.14 0.99
<1.7
0.74 1.59
10
IS
1 29 0.09 0.98 0.91 3.15
2
120
HL232AIS/UV/HE qv II
46
0.39
0.99
0.77 1.67
<10 277 0.17
1
120
28
0.24
0.92 3.28
277 0.10 0.97 <12
2
120
HL232APS/UV/HE v XII
48
0.41 0.99
0.75 1.56
10
PS
277 0.18 0.98
1
120
31
0.26 0.99
0.84
2.71
277 0.12 0.97 2.67 12
3
120
HL332AIS/UV/HE qv VIII
68 0.58
0.99
0.76 1.12
10
IS
277 70 0.26 0.77 1.10
2
120 53 0.45 0.88 1.66
277 54 0.20 0.96 0.90 1.67 12
3
120
HL332APS/UV/HE v XIII
73
0.60 0.99
0.75 1.03
10
PS
277 0.27 0.98
2
120
56
0.47 0.99
0.84 1.50
277 0.21 0.97 12
4
120
HL432AIS/UV/HE qv IX
92
0.77 0.99 0.76 0.83
10
IS
277 0.33 0.98 0.75 0.82
3
120
75
0.63 0.99 0.82 1.09
277 0.27 0.97 0.81 1.08
4
120
HL432APS/UV/HE v X
91
0.77 0.99 0.71 0.79
PS
277 0.34 0.98 0.72 0.80
3
120 75 0.63 0.99 0.78 1.05
277 76 0.28 0.98 0.79 1.04
F32T8
30W
1
120
HL132BIS/UV/HE qv
W
26
0.22 0.99
<1.7
0.87
IS
277 0.11 0.98
2
120
HL232BIS/UV/HE qv V
52
0.44
0.99
0.87 1.67
<10 277 0.19
1
120
32
0.27
1.05 3.28
277 0.12 0.98 <12
2
120
HL232BPS/UV/HE v XII
56
0.47 0.99
0.88 1.57
10 PS
277 0.21
0.98
1
120
36
0.30
1.02 2.83
277 0.14 0.96
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
F32T8
28W
3
120
HL332CIS/UV/HE qv
W
VIII
95 0.86 0.99
<1.7
1.18
1.24
10
IS
277 92 0.38 0.98 1.28
2
120 71 0.65 0.99
1.28
1.80
277 69 0.28 0.98 1.86
3
120
HL332CPS/UV/HE v XIII
99
0.83 0.99
1.18 1.19
PS
277 0.36 0.98
2
120
76
0.64 0.99
1.34 1.76
277 0.28 0.97 12
High Ballast Factor
Low Ballast Factor
Normal Ballast Factor
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 25 11/8/11 12:50 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 25
T8 Lamps
Electronic Linear
Fluorescent Ballasts
30 & 32
Watt
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
F32T8
30W
3
120
HL332BIS/UV/HE qv
W
VIII
79
0.66 0.99
<1.7
0.87 1.10
10
IS
0.29 0.98
2
120
60
0.50 0.99
0.98 1.63
277 0.22 0.97 12
3
120
HL332BPS/UV/HE v XIII
81 0.68 0.99
0.88
1.09
10 PS
277 82 0.30 0.98 1.07
2
120 62 0.52 0.99
0.95
1.53
277 63 0.23 0.97 1.51
4
120
HL432BIS/UV/HE qv IX
105 0.88 0.99 0.86
0.82
10
IS
277 106 0.38 0.98 0.87
3
120
85
0.71 0.99
0.93 1.09
277 0.31 0.97 12
4
120
HL432BPS/UV/HE v X
104
0.87 0.99 0.83
0.80
10 PS
277 0.38 0.98 0.84
3
120
86
0.72 0.99 0.88
1.03
277 0.32 0.98 0.89
F32T8
30W
2
120
HL232CIS/UV/HE qv
W
V
70 0.59 0.99
<1.7
1.18
1.69
10
IS
277 68 0.25 0.98 1.74
1
120
43
0.36 0.99
1.40 3.26
277 0.16 0.95 15
2
120
HL232CPS/UV/HE v XII
72
0.60 0.99
1.18 1.64
10
PS
277 0.26 0.98
1
120
45
0.38 0.99
1.37 3.04
277 0.17 0.96 12
3
120
HL332CIS/UV/HE qv VIII
104 0.88 0.99
1.18
1.13
10
IS
277 101 0.38 0.98 1.17
2
120 78 0.66 0.99
1.28
1.64
277 76 0.29 0.98 1.68
3
120
HL332CPS/U/HE v XIII
104
0.88 0.99
1.18 1.13
PS
277 0.38 0.98
2
120
80
0.67 0.99
1.33 1.66
277 0.30 0.97 12
30 Watt
32 Watt
q v
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
F32T8
2
120
HL232RIS/12
W
V
57 0.80 0.60
1.7
0.88 1.54
150
IS
1 37 0.55 0.57 1.00 2.70
4
120 HL432RIS/12 IX
98 1.33 0.61
<1.7
0.71 0.72
IS
3 82 1.16 0.59 0.80 0.98
F32T8
32W
2
347
HL232AIS/34 qv
W
V
50 0.15 0.99
<1.7
0.76 1.52
10
IS
1 30 0.09 0.98 0.84 3.00
2
120
HL232AIS/UV/HE qv II
50
0.42
0.99
0.80 1.60
<10
277 0.18
1
120
31
0.26
0.98 3.16
277 0.11 0.98
Residential
Low Ballast Factor
Normal Ballast Factor
High Ballast Factor
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 26 11/8/11 12:50 PM
T8 Lamps
26 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
v
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
Electronic Linear
Fluorescent Ballasts
32
Watt
q
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
F32T8
32W
2
120
HL232APS/UV/HE v W XII
52
0.44 0.99
<1.7
0.77 1.48
10
PS
277 0.19 0.98
1
120
33
0.28 0.99
0.86 2.61
277 0.12 0.98
3
120
HL332AIS/UV/HE qv
W
VIII
75 0.63 0.99
<1.7
0.78
1.04
IS
277 74 0.28 0.98 0.77
2
120
57
0.50 0.99
0.92 1.61
277 0.22 0.97 12
3
120
HL332APS/UV/HE v XIII
79
0.65 0.99
0.77 0.97
10
PS
277 0.29 0.98
2
120
58
0.49 0.99
0.86 1.48
277 0.21 0.98
4
120
HL432AIS/UV/HE qv IX
98 0.82 0.99 0.78
0.80
IS
277 96 0.35 0.98 0.77
3
120 81 0.68 0.99 0.87 1.07
277 78 0.28 0.97 0.86 1.10 12
4
120
HL432APS/UV/HE v X
97
0.82
0.99
0.74 0.76
10 PS
277 0.35
3
120
78
0.66 0.78 1.00
277 0.29 0.98 0.79 1.01
F32T8
32W
1
120
HL132BIS/UV/HE qv
W
28
0.24 0.99
<1.7
0.87 3.11 10
IS
277 0.12 0.98
2
120
HL232BIS/UV/HE qv V
57 0.48
0.99
0.90
1.58
<10
277 58 0.21 0.91
1
120
35
0.31
1.09 3.11
277 0.14 0.98
2
120
HL232BPS/UV/HE v XII
60
0.50 0.99
0.88 1.47
10
PS
277 0.22
0.98
1
120
37
0.31
0.99 2.68
277 0.14 0.93
3
120
HL332BIS/UV/HE qv VIII
83 0.69 0.99 0.87 1.05
IS
81 0.29 0.98 0.88 1.09
2
120 64 0.53 0.99 1.02 1.59
277 63 0.23 0.97 1.01 1.60 12
3
120
HL332BPS/UV/HE v XIII
88
0.73 0.99
0.88 1.00
10
PS
277 0.32 0.98
2
120 68 0.57 0.99
0.98
1.44
277 69 0.25 0.98 1.42
4
120
HL432BIS/UV/HE qv IX
110 0.92
0.99
0.88 0.80
IS
277 106 0.38 0.87 0.82
3
120 89 0.74 0.94 1.06
277 88 0.32 0.98 0.95 1.08
4
120
HL432BPS/UV/HE v X
114
0.95 0.99
0.86
0.75
PS
277 0.42 0.98 0.76
3
120
95
0.79 0.99 0.92 0.97
277 0.35 0.98 0.93 0.99
F32T8
32W
2
120
HL232CIS/UV/HE qv
W
V
77
0.65 0.99
<1.7
1.19 1.55
10
IS
277 0.28 0.98
1
120
48
0.40 0.99
1.45 3.03
277 0.18 0.96 12
2
120
HL232CPS/UV/HE v XII
78
0.65 0.99
1.18 1.51
10
PS
277 0.29 0.98
1
120
50
0.42 0.99
1.42 2.84
277 0.19 0.97 12
32 Watt
Low Ballast Factor
Normal Ballast Factor
High Ballast Factor
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 27 11/8/11 12:50 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 27
T8 Lamps
Electronic Linear
Fluorescent Ballasts
32 & 40
Watt
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
q v
F32T8
32W
3
120
HL332CIS/UV/HE qv
W
VIII
111 0.98
0.99
<1.7
1.18
1.06
10 IS
277 108 0.42 1.09
2
120 82 0.71
1.27
1.55
277 81 0.32 0.98 1.57
3
120
HL332CPS/UV/HE v XIII
114
0.96 0.99
1.18 1.04
10 PS
277 0.41 0.98
2
120
88
0.73 0.99
1.35 1.53
277 0.32 0.98
32 Watt
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
40 Watt
F40T8 1 120
HL232RIS/12
W V 42 0.60 0.57 1.7 1.00 2.38 150 IS
F40T8
40W
1 347
HL232AIS/34 qv
W
V 36 0.11 0.99
<1.7
0.86 2.39 10 IS
1
120
HL232AIS/UV/HE qv
II 38
0.32 0.99 0.98 2.57
<10 IS
277 0.14 0.98 0.95 2.50
1
120
HL232APS/UV/HE v XII
38 0.32 0.99
0.82
2.16
10
PS
277 39 0.14 0.98 2.10
3
120
HL332AIS/UV/HE qv VIII
66 0.55 0.99 0.81 1.23
IS
277 67 0.24 0.97 0.82 1.22 12
2
120
HL332APS/UV/HE v XIII 74
0.61 0.99
0.82 1.12
10
PS
277 0.27 0.98
3
120
HL432AIS/UV/HE qv IX
97 0.81 0.99 0.79 0.81
IS
277 98 0.35 0.98 0.80 0.82
3
120
HL432APS/UV/HE v X 9 9
0.83
0.99
0.77 0.78
PS
277 0.36 0.79 0.80
F40T8
40W
1
120
HL232BIS/UV/HE qv
W
V 42
0.34
0.99
<1.7
1.05 2.50
<10 IS
277 0.15 1.02 2.44
1
120
HL232BPS/UV/HE v XII 45
0.38 0.98 0.99 2.20
10
PS
277 0.17 0.97 1.01 2.24
2
120
HL332BIS/UV/HE qv VIII
78 0.65 0.99 0.92 0.92
IS
277 77 0.28 0.98 0.88 0.88
3
120
HL332BPS/UV/HE v XIII
80 0.67 0.99
0.95
1.19
PS
277 81 0.30 0.98 1.17
3
120
HL432BIS/UV/HE qv IX
109 0.91 0.99 0.90 0.83
IS
277 108 0.39 0.98 0.89 0.82
3
120
HL432BPS/UV/HE v X 111
0.93 0.99 0.88
0.80 PS
277 0.41 0.98 0.89
F40T8
40W
1
120
HL232CIS/UV/HE qv
W
V
57 0.48 0.99
<1.7
1.32
2.32
10
IS
277 58 0.22 0.97 1.35 12
1
120
HL232CPS/UV/HE v XII 58
0.49 0.99
1.35 2.33
10
PS
277 0.22 0.97 12
High Ballast Factor
Residential
Low Ballast Factor
Normal Ballast Factor
High Ballast Factor
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 28 11/8/11 12:50 PM
28 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 28 28
T8 Lamps
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
Electronic Linear
Fluorescent Ballasts
40 - 59
Watt
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
F58T8
4
120
HL454HO/PS/UV S XI
210
1.74
0.99
1.7
0.95 0.45
10
PS
277 0.75
3
120
160
1.35
0.98 0.61
277 0.59 0.98
2
120
108
0.90 0.99
0.95 0.88
277 0.41 0.86 12
1
120
58
0.48 0.98
0.98 1.69
10
277 0.24 0.90 15
F96T8
59W
1
120
HL259IS/UV W V
113
0.96
0.98
1.7
0.85 0.75
10
IS
277 0.42
2
120 68 0.57 0.99 1.02
1.50
277 70 0.26 0.97 1.05 12
F96T8/ES
57W
1
120
HL259IS/UV W V
104 0.88 0.98
1.7
0.81
0.77
10
IS
277 103 0.38 0.97 0.80 12
2
120 66 0.56 0.98 1.03 1.56 10
277 67 0.25 0.96 1.04 1.55 12
F96T8/ES
51W
1
120
HL259IS/UV W V
94
0.80
0.97
1.7
0.82 0.87 12
IS
277 0.35
2
120
61
0.52 0.98
1.06 1.74
10
277 0.23 0.96 12
F72T8
46W
1
120
HL259IS/UV W V
90 0.77 0.97
1.7
0.83
0.92 12
IS
277 91 0.34 0.96 0.84
2
120 56 0.48 0.98 1.03
1.84
10
277 57 0.22 0.95 1.05 15
58 Watt
59 Watt
57 Watt
51 Watt
46 Watt
40 Watt
F40T8
40W
2
120
HL332CIS/UV/HE qv
W
VIII 101
0.83 0.99
<1.7
1.26 1.25
10
IS
277 0.37 0.98
2
120
HL332CPS/UV/HE v XIII 104
0.88 0.99
1.18 1.13 PS
277 0.38 0.98
High Ballast Factor
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 29 11/8/11 12:50 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 29
T12 & T12 HO Lamps
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
F34T12 or
F34T12/U
2
120 HL240RS/12
W
VII
63 0.53
0.98
1.63 0.85 1.35
10
RS
1 40 0.34 1.59 1.10 2.75
2 120 HL240R/RS/12 XII 46 0.58 0.66 <1.7 0.60 1.30 150
2
120
HL240RS/UV VII
63
0.53
0.98
1.63 0.85 1.35
10
277 0.23
1
120
40
0.34
1.59 1.10 2.75
277 0.15 0.96
F40T12 or
F40T12/U
2
120 HL240RS/12
W
VII
74 0.62
0.99
1.66 0.88 1.19
10
RS
1 47 0.40 1.57 1.10 2.34
2 120 HL240R/RS/12 XII 49 0.67 0.61 <1.7 0.54 1.10 150
2
120
HL240RS/UV VII
74
0.64 0.99
1.66 0.88 1.19
10
277 0.28 0.98
1
120
47
0.40 0.99
1.57 1.10 2.34
277 0.18 0.97
F40T12
(25W Shoplight)
2
120 HL240RS/12
W
VII
78 0.66
0.99
1.64 1.40 1.79
10
RS
1 51 0.43 1.58 1.70 3.33
2 120 HL240R/RS/12 XII 48 0.60 0.67 <1.7 0.53 1.10 150
2
120
HL240RS/UV VII
78
0.66 0.99
1.64 1.40 1.79
10
277 0.27 0.98
1
120
51
0.43 0.99
1.58 1.70 3.33
277 0.18 0.97
F48T12/HO
60W
2 120 HL296HO/RS/12
W VII 104
0.88
0.99
1.7 0.90 0.87
10
RS
2
120
HL296HO/RS/UV 0.96 15
277 0.38
F60T12/HO
75W
2 120 HL296HO/RS/12
W VII 132
1.10
0.99
1.7 0.90 0.68
10
RS
2
120
HL296HO/RS/UV
0.97 12
277 0.47 0.96 15
F72T12/HO
85W
2 120 HL296HO/RS/12
W VII 154
1.30 0.99
1.7 0.90 0.58
10
RS
2
120
HL296HO/RS/UV
277 0.56 0.97 12
F96T12/HO/ES
95W
2 120 HL296HO/RS/12
W VII 164
1.38
0.99
1.7 0.90 0.55
10
RS
2
120
HL296HO/RS/UV
0.98
277 0.60 0.97 12
F96T12/HO
110W
2 120
HL296HO/RS/12
W VII
196 1.65
0.99
1.7
0.90 0.46
10
RS
1 120 104 0.88 0.92 0.88
2
120
HL296HO/RS/UV
196
1.65
0.85 0.43
277 0.71 0.98
1
120
104
0.88 0.95
0.92 0.88 15
277 0.38 0.94
F30T12
2
120 HL240RS/12
W
VII
58 0.49 0.99 1.65 0.88 1.52
10
RS
1 38 0.32 0.98 1.59 1.00 2.63
2 120 HL240R/RS/12 XII 40 0.51 0.66 <1.7 0.58 1.45 150
2
120
HL240RS/UV VII
58
0.49 0.99
1.65 0.88 1.52
10
277 0.22 0.97
1
120
38
0.32 0.98
1.59 1.00 2.63
277 0.14 0.95
Electronic Linear
Fluorescent Ballasts
30 - 110
Watt
30 Watt
F40 & F40 Energy Savers
60-110 Watt High Output
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 30 11/8/11 12:50 PM
30 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
T12 Slimline Lamps
Electronic Linear
Fluorescent Ballasts
30 - 75
Watt
Notes: *Case Style: Approvals:
- HL Type - Hazardous Location
- Transient Protection meets
ANSI/IEEE C62.41 Cat. A
- Sound Rated: A
- Minimum Starting Temperature: -20C
- Maximum Case Temperature: 90C
- Meets FCC Part 18 (Class B) Consumer Limits
- Lamp end-of-life protection
- RS - Rapid Start
- PS - Programmed Start
- IS - Instant Start
Add following suffx for complete part number:
S - Slim Case
W - Wire lead
F48T12/ES
30W
2 120 HL275IS/12
W V 64
0.56
0.95 <1.7
0.92 1.44
15 IS
2
120
HL275IS/UV 0.95 1.48
277 0.24
F48T12
40W
2 120 HL275IS/12
W V
76 0.67
0.95 <1.7
0.92 1.21
15 IS
2
120
HL275IS/UV 76
0.67
0.95 1.25
277 0.29
F60T12
50W
2 120
HL275IS/12
W V
85 0.72
0.99
<1.7
0.90 1.06
12
IS
1 120 56 0.47 1.02 1.82
2
120
HL275IS/UV
85 0.72 0.99
0.90 1.06
10
277 86 0.32 0.97 12
1
120 56 0.47 0.99
1.02
1.82 10
277 58 0.22 0.97 1.76 12
F64T12
52W
2 120
HL275IS/12
W V
93 0.78 0.99
<1.7
0.90 0.97
12
IS
1 120 60 0.51 0.98 1.03 1.72
2
120
HL275IS/UV
92 0.78 0.99
0.90 0.97
10
277 93 0.35 0.97
12
1
120 60 0.51 0.98
1.03
1.72
277 64 0.24 0.97 1.61
F72T12
57W
2 120
HL275IS/12
W V
107 0.92
0.97
<1.7
0.90 0.84
12
IS
1 120 66 0.57 1.04 1.58
2
120
HL275IS/UV
106 0.92
0.97
0.90 0.84
277 107 0.40
1
120
66
0.57
1.04 1.58
277 0.25 0.95 15
F84T12
70W
2 120
HL275IS/12
W V
122 1.04
0.98 <1.7
0.88 0.72
10
IS
1 120 75 0.64 1.05 1.40
2
120
HL275IS/UV
123
1.04
0.88 0.72
12
277 0.45
1
120 75 0.64
1.05
1.40
277 76 0.28 1.38
F96T12/ES
60W
2 120
HL275IS/12
W V
113 0.95
0.99
<1.7
0.88 0.78
10
IS
1 120 71 0.60 1.05 1.48
2
120
HL275IS/UV
112 0.95
0.99
0.90
0.80
277 115 0.42 0.78
1
120 71 0.60
1.05
1.48
277 72 0.26 0.98 1.46 12
F96T12
75W
2 120
HL275IS/12
W V
133 1.12
0.99
<1.7
0.86 0.65
10 IS
1 120 83 0.70 1.02 1.23
2
120
HL275IS/UV
133 1.12
0.99
0.90
0.68
277 135 0.49 0.67
1
120 83 0.70
1.00
1.20
277 84 0.31 1.19
30-75 Watt Slim Line
Lamp Type
No. of
Lamps
Input
Volts
Hatch Part
Number
*Case
Style
Wire
Diagram
Input
Watts
Input
Current
(Amps)
Power
Factor
Crest
Factor
Ballast
Factor
Ballast
Effcacy
Factor
Max.
THD %
Starting
Method
Case Styles and Wire Diagrams can be found on Pgs. 31-32
Dimensions can be found on Pg. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 31 11/8/11 12:50 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 31
Wire Diagrams & Case Styles
WHITEB LUE
RED
RED
BLUE
YELLOW
YELLOW
BLACK
BALLAST
Omit yellow connection for one lamp operation.
LAMP
LAMP
LAMP
BLUE
BLUE
RED
WHITE
BLACK
Two Lamps Application
(Cap off 1 blue lead for 1 lamp application).
BALLAST
WHITE
RED
RED
BLACK
RED
RED
LINE
BLUE
BLUE
BLUE
BLUE
LAMP
LAMP
BALLAST
LINE
BLACK BLUE
BLUE
RED
RED
WHITE
YELLOW
YELLOW



LAMP
For one lamp operation, please cap off blue wires.
BALLAST
LAMP
LAMP
LAMP
BLACK
WHITE
Three Lamps Application
(Cap off blue lead for 2 lamps).
BALLAST
RED
BLUE
BLUE
BLUE
Four Lamps Application
(Cap off any blue lead for 3 lamp application).
LAMP
LAMP
LAMP
LAMP

BLACK
WHITE
YELLOW
RED
RED
BLUE
BLUE
IV. V.
VI.
VII.
VIII. IX.
LAMP
LAMP
LAMP
LAMP
YELLOW
WHITE
BLACK
RED
RED
BLUE
BLUE
YELLOW
RED/WHITE
RED/WHITE
BLUE/WHITE
BLUE/WHITE
BALLAST
X.
LINE
S
LAMP
LAMP
3 LAMPS
BALLAST
BLUE/WHITE BROWN
BROWN
YELLOW
YELLOW
RED
RED
BLUE
BLUE
BLUE/WHITE
RED/WHITE
RED/WHITE
RED/WHITE
BLACK
WHITE
LAMP
XI.
B A L L A S T S MU S T B E G R O U N D E D
Fluorescent Ballast Catalog 2011_Rev2.0.indd 32 11/8/11 12:50 PM
32 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Wire Diagrams & Case Styles
S. Slimline case with terminals
W.
Wire lead
M
W
H
L
M
L
H
W
XII. XIII.
XIV. XV.
LAMP
LAMP
YELLOW
WHITE
BLACK
RED
RED
BLUE
BLUE
YELLOW

BALLAST
LAMP
LAMP
LAMP
YELLOW
WHITE
BLACK
RED
RED
BLUE
BLUE
YELLOW
RED/WHITE
RED/WHITE
BALLAST
LAMP
LAMP
LAMP
LAMP
YELLOW
WHITE
BLACK
RED
RED
BLUE
BLUE
YELLOW
RED/WHITE
RED/WHITE
BLUE/WHITE
BLUE/WHITE
BALLAST
BALLAST
S
4 LAMPS
LAMP
LAMP
LAMP
LAMP
BROWN
BROWN
YELLOW
YELLOW
RED
RED
BLUE
BLUE
BLUE/WHITE
BLUE/WHITE
RED/WHITE
ORANGE
ORANGE
BLACK
WHITE LINE
B A L L A S T S MU S T B E G R O U N D E D
A full list of Case Dimensions can be found on Pgs. 34
Fluorescent Ballast Catalog 2011_Rev2.0.indd 33 11/8/11 12:50 PM
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 33
Product Index & Dimensions
HATCH PART
NUMBER
PAGES
DIMENSIONS MOUNTING*
Length Width Height M1 M2 M3
HC113RS/12/W 6 4.00" 1.87" 1.19" 3.58"
HC113RS/12/WJ 6 4.00" 1.87" 1.19" 3.58" 2.00" 0.63"
HC113RS/HP/12/W 6 4.00" 1.87" 1.19" 3.58" 0.63"
HC113RS/HP/12/WJ 6 4.00" 1.87" 1.19" 3.58" 2.00" 0.63"
HC118RS/12/W 7 4.00" 1.87" 1.19"
HC118RS/12/WJ 7 4.00" 1.87" 1.19" 3.58" 2.00" 0.63"
HC118RS/HP/12/W 7 4.00" 1.87" 1.19" 3.58" 0.63"
HC118RS/HP/12/WJ 7 4.00" 1.87" 1.19" 3.58" 2.00" 0.63"
HC126RS/HP/12/W 8, 9 4.00" 1.87" 1.19" 3.58" 0.63"
HC126RS/HP/12/WJ 8, 9 4.00" 1.87" 1.19" 3.58" 2.00" 0.63"
HC126RS/12/W 8, 9 4.00" 1.87" 1.19"
HC126RS/12/WJ 8, 9 4.00" 1.87" 1.19" 3.58" 2.00" 0.63"
HC142RS/12/W 8, 9, 10, 11 4.00" 1.87" 1.19" 3.58" 2.00" 0.63"
HC142RS/12/WJ 8, 9, 10, 11 4.00" 1.87" 1.19" 3.58" 2.00" 0.63"
HC155RS/12/W 12 4.00" 1.87" 1.19" 3.58" 0.63"
HC155RS/12/WJ 12 4.00" 1.87" 1.19" 3.58" 2.00" 0.63"
HC213PS/UV/D 6, 7 4.34" 2.40" 1.00" 4.63"
HC213PS/UV/DJ 6, 7 4.34" 2.40" 1.00" 4.63"
HC213RS/12/DJ 6, 7 5.00" 2.40" 1.00" 4.63"
HC213RS/12/W 6, 7 4.00" 1.87" 1.19"
HC213RS/12/WJ 6, 7 4.00" 1.87" 1.19" 3.58" 2.00" 0.63"
HC213RS/HP/12/DJ 6, 7 4.34" 2.40" 1.00" 4.63"
HC213PS/34/D 6, 7 4.34" 2.40" 1.00" 4.63"
HC213PS/34/DJ 6, 7 4.34" 2.40" 1.00" 4.63"
HC213PS/UV/K 13
HC218PS/UV/D 7, 8, 9 4.34" 2.40" 1.00" 2.00" 4.63"
HC218PS/UV/DJ 7, 8, 9 4.34" 2.40" 1.00" 2.00" 4.63"
HC218RS/12/DJ 7, 9 5.00" 2.40" 1.00" 4.63"
HC218RS/12/W 7, 9 5.00" 2.40" 1.00" 3.58" 0.63"
HC218RS/12/WJ 7, 9 4.00" 1.87" 1.19" 3.58" 2.00" 0.63"
HC218RS/HP/12/DJ 7, 9 4.34" 2.40" 1.00" 4.63"
HC218PS/34/D 7, 9 4.34" 2.40" 1.00" 2.00" 4.63"
HC218PS/34/DJ 7, 9 4.34" 2.40" 1.00" 2.00" 4.63"
HC218PS/UV/K 13
HC226PS/UV/D 8, 9, 10, 11, 12 9.50" 1.16" 1.05" 9.00"
HC226PS/UV/DJ 8, 9, 10, 11, 12 9.50" 1.16" 1.05" 9.00"
HC226RS/12/DJ 8, 9, 10, 11, 12 5.00" 2.40" 1.00" 4.63"
HC226RS/12/W 8, 9, 10, 11, 12 4.00" 1.87" 1.19" 3.58" 0.63"
HC226RS/12/WJ 8, 9, 10, 11, 12 4.00" 1.87" 1.19" 3.58" 2.00" 0.63"
HC226/PS/34/D 8, 9, 10, 11, 12 4.34" 2.40" 1.00" 4.63"
HC226/PS/34/DJ 8, 9, 10, 11, 12 4.34" 2.40" 1.00" 4.63"
HC226/RS/HP/12/D 9, 10 4.34" 2.40" 1.00" 4.63"
HC226/RS/HP/12/DJ 9, 10, 11 4.34" 2.40" 1.00" 4.63"
HC226PS/UV/K 13
HC242PS/UV/D 9, 10, 11, 12 5.00" 3.00" 1.38" 4.63"
HC242PS/UV/DJ 9, 10, 11, 12 5.00" 3.00" 1.38" 4.63"
HC242PS/UV/K 13
HC1C3032RS/12W 15 2.84" 1.81" 1.18" 3.10"
Compact Fluorescent Ballasts
SMART
KIT

SMART
KIT

SMART
KIT

SMART
KIT

*For more on mounting please see case styles on page 14


Fluorescent Ballast Catalog 2011_Rev2.0.indd 34 11/8/11 12:50 PM
34 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Product Index & Dimensions
HATCH PART
NUMBER
PAGES
DIMENSIONS MOUNTING*
Length Width Height M1 M2 M3
HL132BIS/UV/HE/W 18, 20, 21, 23, 24, 26 9.50" 1.16" 1.05" 9.0"
HL139RS/12/W 8, 10, 11, 16, 17 9.00" 0.95" 0.95" 8.75"
HL224HO/PS/UV/S 8, 10, 11, 15, 16 16.7" 1.18" 1.00" 16.4"
HL224HO/PS/UV/W 8, 10, 11, 15, 16 9.45" 1.35" 1.06" 8.96"
HL228HE/PS/UV/S 16 16.7" 1.18" 1.00" 16.4"
HL228HE/PS/UV/W 16 9.45" 1.35" 1.06" 8.96"
HL232AIS/34/W 18, 19, 25, 27 9.50" 1.70" 1.15" 8.9"
HL232APS/UV/HE/W 18, 19, 21, 22, 24, 26, 27 9.50" 1.38" 1.18" 8.9"
HL232AIS/UV/HE/W 18, 19, 21, 22, 24, 26, 27 4.34" 2.40" 1.00" 4.63"
HL232BIS/UV/HE/W 18, 20, 21, 23, 24, 26, 27 9.50" 1.16" 1.05" 9.0"
HL232BPS/UV/HE/W 18, 20, 21, 23, 24, 26, 27 9.50" 1.38" 1.18" 8.9"
HL232CIS/UV/HE/W 19, 20, 22, 23, 25, 26, 27 9.50" 1.38" 1.18" 8.9"
HL232CPS/UV/HE/W 19, 20, 22, 23, 25, 26, 27 9.50" 1.38" 1.18" 8.9"
HL232RIS/12/W 18, 19, 25, 29 9.50" 1.16 0.88" 8.9
HL239HO/PS/UV/S 8, 10, 11, 15, 16, 17, 27 16.7" 1.18" 1.00" 16.4"
HL239HO/PS/UV/W 8, 10, 11, 15, 16, 17 9.45" 1.35" 1.06" 8.96"
HL240RS/12/W 19, 25, 29 6.46" 1.89" 1.00" 6.0"
HL240RS/UV/W 29 9.50" 1.38" 1.10" 8.9"
HL240R/RS12/W 29 6.46" 1.37" 1.00" 6.0"
HL254HO/PS/UV/S 10, 12, 15, 17 16.7" 1.18" 1.00" 16.4"
HL254HO/PS/UV/W 10, 12, 15, 17 9.45" 1.35" 1.06" 8.96"
HL259IS/UV/W 28 9.45" 1.38" 1.18" 8.9"
HL275IS/12/W 30 9.45" 1.80" 1.37" 8.9"
HL275IS/UV/W 30 9.45" 1.80" 1.37" 8.9"
HL296HO/RS/12/W 29 11.8" 2.15" 1.61" 11.0"
HL296HO/RS/UV/W 29 11.8" 2.15" 1.61" 11.0"
HL332AIS/UV/HE/W 18, 19, 21, 22, 24, 26, 27 9.50" 1.38" 1.18" 8.9"
HL332APS/UV/HE/W 18, 19, 21, 22, 24, 26, 27 9.50" 1.65" 1.18" 8.9"
HL332BIS/UV/HE/W 18, 20, 21, 23, 25, 26, 27 9.50" 1.38" 1.18" 8.9"
HL332BPS/UV/HE/W 18, 20, 21, 23, 25, 26, 27 9.50" 1.65" 1.18" 8.9"
HL332CIS/UV/HE/W 19, 20, 22, 24, 25, 26, 28 9.50" 1.38" 1.18" 8.9"
HL332CPS/UV/HE/W 19, 20, 22, 24, 25, 26, 28 9.50" 1.65" 1.18" 8.9"
HL432AIS/UV/HE/W 18, 19, 21, 23, 24, 26, 27 9.50" 1.38" 1.18" 8.9"
HL432APS/UV/HE/W 19, 20, 22, 23, 25, 26, 27 9.50" 1.65" 1.18" 8.9"
HL432BIS/UV/HE/W 18, 20, 22, 23, 25, 26, 27 9.50" 1.38" 1.18" 8.9"
HL432BPS/UV/HE/W 19, 20, 22, 23, 25, 26, 27 9.50" 1.65" 1.18" 8.9"
HL432RIS/12/W 18, 19, 25 9.50" 1.70" 1.15" 8.9"
HL454HO/PS/UV/S 11, 12, 17 16.7" 1.70" 1.18" 16.4"
HL454HO/PS/UV/W 11, 12, 15, 17, 28 9.45" 2.28" 1.03" 9.0"
Linear Fluorescent Ballasts
*For more on mounting please see case styles on page 32
Fluorescent Ballast Catalog 2011_Rev2.0.indd 35 11/8/11 12:50 PM
Our Most Popular Lamps*
A
b
o
u
t

H
a
t
c
h

F
l
u
o
r
e
s
c
e
n
t

L
a
m
p
s
Hatch Lamps Feature:
Very low mercury content Less
than 2.8 mg
Long Lamp Life- 35,000 Hours
when operated at 3 hours per start
for XL models
Ultra high quality manufacturing in
Germany
Energy saving 25w and 28w T8
models
High CRI- 85+
Available with Gemini Lamp and
Ballast Systems
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 35
Hatch Offers a Full Line of T5, T8 and T12 Lamps
Hatch Offers a Full Line of T5, T8 and T12 Lamps
ANSI
Our Most Popular Lamps*
* Note: For a complete list of Hatch Linear
Fluorescent Lamps, please visit our website.
Hatch Fluorescent Lamps have been designed and manufactured
to precise specifcations in Germany, ensuring the highest
quality and best performance in the industry.
Lamp Part Number Lamp Type Pack Quantity
70800 F14T5/830 25PK
70801 F14T5/835 25PK
70802 F14T5/841 25PK
70803 F28T5/830 25PK
70804 F28T5/835 25PK
70805 F28T5/841 25PK
70806 F24T5/830/HO 25PK
70807 F24T5/835/HO 25PK
70808 F24T5/841/HO 25PK
70809 F54T5/830/HO 25PK
70810 F54T5/835/HO 25PK
70811 F54T5/841/HO 25PK
70812 F54T5/850/HO 25PK
70813 F21T5/830 25PK
70814 F21T5/835 25PK
70815 F21T5/841 25PK
70828 F14T5/860 25PK
GEMINI
Lamp and Ballast. Perfectly Matched.
Certifcations
Certifcations
Fluorescent Ballast Catalog 2011_Rev2.0.indd 36 11/8/11 12:50 PM
36 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Lamp & Ballast Pairing Guide
HL224HO-PS-UV-W X
HL224HO-PS-UV-S X
HL228HE-PS-UV-S X X X X X
HL228HE-PS-UV-W X X X X X
HL232AIS-34-W X X X
HL232AIS-UV-HE-W X X X
HL232BIS-UV-HE-W X X X
HL232CIS-UV-HE-W X X X
HL232BPS-UV-W X X X
HL239HO-PS-UV-W X X
HL239HO-PS-UV-S X X
HL254-HO-PS-UV-W X X
HL254HO-PS-UV-S X X
HL332AIS-UV-HE-W X X X
HL332BIS-UV-HE-W X X X
HL332CIS-UV-HE-W X X X
HL332BPS-UV-W X X X
HL432AIS-34-W X X X
HL432AIS-UV-HE-W X X X
HL432BIS-UV-HE-W X X X
HL432BPS-UV-W X X X
HL454HO-PS-UV-W X X
F
1
4
T
5
F
1
4
T
5
X
L
F
2
1
T
5
F
2
4
T
5
H
O
F
2
8
T
5
F
2
8
T
5
X
L
F
3
9
T
5
H
O
F
5
4
T
5
H
O
F
5
4
T
5
H
O
X
L
F
3
2
T
8
H
E
2
5
W
F
3
2
T
8
H
E
2
8
W
F
3
2
T
8
LAMP TYPE
BALLAST
Fluorescent Ballast Catalog 2011_Rev2.0.indd 37 11/8/11 12:50 PM
I nst al l at i on and Test i ng Gui del i nes f or
El ectroni c Fl uorescent Bal l asts
37 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Wiring and installation of electronic fluorescent ballasts
Please make certain that the black and white input wires (primary side) of the
fluorescent ballast are connected to the power line (120 volts or 277 volts) using
wire nuts. Also make sure that the output wires (secondary side) of the fluorescent
ballast are connected to the fluorescent light source using wire terminal blocks of the
appropriate size. For compact fluorescent models with push terminals, please ensure
that all wires are seated firmly in each terminal and that proper wiring is used.
Testing of fluorescent ballasts
Hatch linear and compact fluorescent ballasts should be tested with an approved lamp
in its actual application fixture. A list of approved lamps can be found in this catalog or
on the individual ballast specification sheets on our website. Testing of fluorescent
ballasts and lamps outside of an application fixture is not recommended due to the
dangers of high strike and operating voltages. Please make note of the starting method
of the Hatch fluorescent ballast that is being tested ( programmed start, rapid start or
instant start) as it will affect the starting and restrike characteristics of the lamp.
Remote Mounting
Most Hatch fluorescent ballasts can be remote mounted at distances of up to
18 feet. Please note that any attempt to remote mount a ballast may compromise its
performance. Variations in wire gauge and lamp type affect the ability of the ballast
to strike a lamp remotely and remote mounting may not work in all configurations.
Please refer to individual specifications on our website for remote mounting
information on each model.
If you have any other questions about the testing and installation of Hatch fluorescent
ballasts please contact the engineering department at our Tampa Headquarters.
Fluorescent Ballast Catalog 2011_Rev2.0.indd 38 11/8/11 12:50 PM
38 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
About Hatch
To view a complete Hatch
Product Catalog, scan this
barcode with your Smartphone.
Since 1985, Hatch has been the recognized market leader in
the design and manufacture of premium power lighting products
and solutions. Hatch offers a complete line of electronic and
magnetic ballasts and transformers for virtually all lighting
applications and is one of the largest independent, full-line power
supply manufacturers in the world.
Current Hatch products include:
Electronic LED Drivers
Electronic HID Ballasts
Linear Fluorescent Ballasts
Compact Fluorescent Ballasts
Electronic Low Voltage Transformers
Remote Transformers
Magnetic HID Ballasts
Fluorescent Lamps
Sign Ballasts
Dont have a scanning App? Search the Apple App Store,
Android Market or BlackBerry App World for a barcode
scanning application
Electrical data and product
specifications in this catalog are
subject to change without notice
Fluorescent Ballast Catalog 2011_Rev2.0.indd 39 11/8/11 12:50 PM
Hatch Transformers, Inc.
Global Headquarters
7821 Woodland Center Blvd.
Tampa, FL 33614
P: 813.288.8006
F: 813.288.8105
www.hatchlighting.com
REV: 2.0 111027
B A L L A S T S , D R I V E R S , T R A N S F O R M E R S & L A M P S F O R A L L L I G H T I N G A P P L I C A T I O N S
Fluorescent Ballast Catalog 2011_Rev2.0.indd 40 11/8/11 12:50 PM
FLUORESCENT
SIGN BALLASTS
Precision Power. Perfect Light.
B A L L A S T S , D R I V E R S , T R A N S F O R M E R S & L A M P S F O R A L L L I G H T I N G A P P L I C A T I O N S
Sign Ballast Catalog 2011_Rev2.0.indd 1 11/8/11 11:35 AM
1
Fluorescent Sign Ballasts
The GSB and ESB series sign
ballasts continue the tradition of
excellence in lighting power
supplies offered by Hatch.
Available in either electronic or
magnetic circuitry, these ballasts
will ft the needs of the OEM sign
builder as well as the lighting
maintenance contractor. With
starting temperatures down to
-20F, the rugged design of these
products ensure long years of
trouble free service. For
superior performance and
excellent reliability trust Hatch
fuorescent sign ballasts.
Instant start circuitry for 800
mA lamps
120-277 V operation, parallel
connections
For use with up to 6 T-12HO
lamps 2-48 ft
Thermally protected/ UL listed
Standard mounting holes and
extra long leads
Rapid start circuitry for 800mA
lamps
120 V operation, series
connections
For use with up to 6 T-12HO
lamps 4-48 ft
Thermally protected/ UL listed
Standard mounting holes and
extra long leads
All Hatch ESB Electronic Sign Ballasts Feature:
All Hatch GSB Magnetic Sign Ballasts Feature:
w
w
w
.
h
a
t
c
h
l
i
g
h
t
i
n
g
.
c
o
m
C
e
r
t
i
f
i
c
a
t
i
o
n
s
C
e
r
t
i
f
i
c
a
t
i
o
n
s
Sign Ballast Catalog 2011_Rev2.0.indd 2 11/8/11 11:35 AM
GSB-0412-12-120 120V 60Hz 1,2 4 12 1.58 175
-20 F
500 V D 11.3
GSB-0620-24-120 120V 60Hz 2,3,4 6 20 2.56 300 590 VI F 12.0
GSB-1224-24-120 120V 60Hz 2,3,4 12 24 2.50 285 790 VII F 15.0
GSB-2040-24-120 120V 60Hz 2,3,4 20 40 4.0 433 810 IX G 22.8
GSB-1240-46-120 120V 60Hz 4,5,6 12 40 3.9 450 800 VIII H 22.0
GSB-2448-46-120 120V 60Hz 4,5,6 24 48 4.5 530 810 X H 23.0
Magnetic Fluorescent Sign Ballasts
ESB-0216-12-UV
120V
50/60Hz
1,2 2 16
1.20
132
-20 F
800 I A 2.8
277V
50/60Hz
0.50
ESB-0432-14-UV
120V
50/60Hz
1,2,3,4 4 32
2.40
267 800 II B 4.5
277V
50/60Hz
1.00
ESB-0848-46-UV
120V
50/60Hz
4,5,6 8 48
3.50
410 860 III C 7.2
277V
50/60Hz
1.50
ESB-1040-14-UV
120V
50/60Hz
1,2,3,4 10 40
3.00
352 1000 IV E 6.9
277V
50/60Hz
1.30
Electronic Fluorescent Sign Ballasts
Part Number
Input
Volts
Lamp Data
Max.
Line
Current
(Amps)
Max.
Input
Power
(Watts)
Min.
Starting
Temp.
(F)
Open
Circuit
Volts
Dimensional
Diagram
Wire
Diagram
Weight
(lbs)
No. Of
Lamps
Lamp Length
Min Max
General Specifications
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 2
Dimensional Diagrams can be found on Pgs. 3-4 | Wire Diagrams can be found on Pgs. 5-6
Sign Ballast Catalog 2011_Rev2.0.indd 3 11/8/11 11:35 AM
All measurements in inches Dimensional Diagrams
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 3
W
H
M
L
W
H
M
L
W
H
M
L
W
H
M
L
W
H
M
L
Length (L) 9.50
Width (W) 2.36
Height (H) 1.70
Mounting (M) 8.90
Lead Length
White, Black 24
Red 96
Blue 96 (2)
II.
III.
IV.
I.
Length (L) 11.65
Width (W) 3.15
Height (H) 1.85
Mounting (M) 11.2
Lead Length
White, Black 24
Yellow, Yellow/Black 120
Red, Blue 120 (2)
Length (L) 14.45
Width (W) 3.23
Height (H) 2.20
Mounting (M) 13.75
Lead Length
White, Black 24
Yellow, Yellow/Black 132
Red, Blue 132 (2)
Length (L) 14.45
Width (W) 3.23
Height (H) 2.20
Mounting (M) 13.75
Lead Length
White, Black 24
Yellow, Yellow/Black 144
Red, Blue 144 (3)
V.
Length (L) 11.75
Width (W) 3.19
Height (H) 2.60
Mounting (M) 11.0
Lead Length
White, Black 18
Yellow 51 (2)
Red, Blue 33 (2)
Sign Ballast Catalog 2011_Rev2.0.indd 4 11/8/11 11:35 AM
Dimensional Diagrams
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105 4
Length (L) 11.75
Width (W) 3.19
Height (H) 2.60
Mounting (M) 11.0
Lead Length
White, Black 24
Brown 46 (2)
Yellow, Blue 75 (2)
Blue/White, Red 46 (2)
Length (L) 19.19
Width (W) 3.19
Height (H) 2.69
Mounting (M) 18.63
Lead Length
White, Black 24
Brown, Blue/White 50 (2)
Yellow 70 (2)
Blue, Org/Blk, Orange 50 (2)
Red 80 (2)
Length (L) 19.19
Width (W) 3.19
Height (H) 2.69
Mounting (M) 18.63
Lead Length
White, Black 24
Brown, Yellow 72 (2)
Red, Blue 80 (2)
Blue/White 54 (2)
Length (L) 19.19
Width (W) 3.19
Height (H) 2.69
Mounting (M) 18.63
Lead Length
White, Black 24
Brown, Blue/White 50 (2)
Yellow 70 (2)
Blue, Org/Blk, Org, Red 50 (2)
VI.
VII.
VIII.
IX.
X.
Length (L) 14.31
Width (W) 3.19
Height (H) 2.63
Mounting (M) 13.75
Lead Length
White, Black 24
Brown 78 (2)
Yellow 70 (2)
Blue/White 52 (2)
Red 32 (2)
Blue 74 (2)
W
H
M
L
W
H
M
L
W
H
M
L
W
H
M
L
W
H
M
L
All measurements in inches
Sign Ballast Catalog 2011_Rev2.0.indd 5 11/8/11 11:35 AM
5 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Wire Diagrams
Black Red
Blue
Blue
BALLAST
LAMP
LAMP
White
Two Lamps Application
(Cap off 1 Blue Lead for 1 lamp application)
A.
B.
Yellow
Black
Blue
Blue
Red
Red
White
Yellow/Black
BALLAST
LAMP
LAMP
LAMP
Three Lamps Application
(Individually cap red and blue leads)
Yellow
Black
Blue
Blue
Red
Red
White
Yellow/Black
BALLAST
LAMP
LAMP
LAMP
LAMP
Four Lamps Application
One and Two Lamp Applications
(Individually cap red and blue leads)
Yellow
Black
Blue
Blue
Red
Red
White
Yellow/Black
BALLAST
LAMP
Yellow
Black
Blue
Blue
Red
Red
White
Yellow/Black
BALLAST
LAMP
LAMP
Black Red
Blue
Blue
BALLAST
LAMP
White
C.
Four and Five Lamp Applications
(Individually cap blue leads)
Six Lamp Application
Yellow
Black
Blue
Blue
Blue
Red
Red
Red
White
Yellow/Black
BALLAST
LAMP
LAMP
LAMP
LAMP
Yellow
Black
Blue
Blue
Blue
Red
Red
Red
White
Yellow/Black
BALLAST
LAMP
LAMP
LAMP
LAMP
LAMP
Yellow
Black
Blue
Blue
Blue
Red
Red
Red
White
Yellow/Black
BALLAST
LAMP
LAMP
LAMP
LAMP
LAMP
LAMP
D.
LINE
BLACK
WHITE
Ballast
Lamp 1
BLUE
BLUE
RED
RED
YELLOW
YELLOW
LINE
BLACK
Ballast
BLUE
BLUE
RED
RED
WHITE
YELLOW
YELLOW
Lamp 1
Lamp 2
E.
One and Two Lamp Applications
(Individually cap red and blue leads)
Three Lamp Application
(Individually cap red lead)
Four Lamp Application
Yellow
Black
Blue
Blue
Red
Red
White
Yellow/Black
BALLAST
LAMP
Yellow
Black
Blue
Blue
Red
Red
White
Yellow/Black
BALLAST
LAMP
LAMP
Yellow
Black
Blue
Blue
Red
Red
White
Yellow/Black
BALLAST
LAMP
LAMP
LAMP
Yellow
Black
Blue
Blue
Red
Red
White
Yellow/Black
BALLAST
LAMP
LAMP
LAMP
LAMP
Sign Ballast Catalog 2011_Rev2.0.indd 6 11/8/11 11:35 AM
6 WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Wire Diagrams
G.
H.
BLUE
BLACK
BROWN
YELLOW
YELLOW
BROWN
WHITE
LINE
Ballast
Lamp 1
Lamp 2
BLUE
RED
RED
BLUE/WHITE
BLUE/WHITE BLUE/WHITE
Lamp 1
Lamp 2
Lamp 3
BLUE
BLACK
BROWN
YELLOW
YELLOW
BROWN
WHITE
LINE
Ballast
BLUE
RED
RED
BLUE/WHITE
Lamp 1
Lamp 2
Lamp 3
Lamp 4
BLUE/WHITE
BLUE
BLACK
BROWN
YELLOW
YELLOW
BROWN
WHITE
Ballast
BLUE
RED
RED
BLUE/WHITE
LINE
BLUE
BLACK
BROWN
YELLOW
YELLOW
BROWN
WHITE
LINE
Ballast
Lamp 1
Lamp 2
BLUE
RED
RED
BLUE/WHITE
BLUE/WHITE
BLUE/WHITE
Lamp 1
Lamp 2
Lamp 3
BLUE
BLACK
BROWN
YELLOW
YELLOW
BROWN
WHITE
LINE
Ballast
BLUE
RED
RED
BLUE/WHITE
Lamp 1
Lamp 2
Lamp 3
Lamp 4
BLUE/WHITE
BLUE
BLACK
BROWN
YELLOW
YELLOW
BROWN
WHITE
Ballast
BLUE
RED
RED
BLUE/WHITE
LINE
Ballast
BLUE
BLACK
LINE
WHITE
BROWN
BROWN
BLUE-WH
BLUE-WH
YELLOW
YELLOW
BLUE
OR-BLK
OR-BLK
ORANGE
ORANGE
RED
RED
Lamp 1
Lamp 2
Lamp 3
Lamp 4
Ballast
BLUE
BLACK
LINE
WHITE
BROWN
BROWN
BLUE-WH
BLUE-WH
YELLOW
YELLOW
BLUE
OR-BLK
OR-BLK
ORANGE
ORANGE
RED
RED
Lamp 1
Lamp 2
Lamp 3
Lamp 4
Lamp 5
Ballast
BLUE
BLACK
LINE
WHITE
BROWN
BROWN
BLUE-WH
BLUE-WH
YELLOW
YELLOW
BLUE
OR-BLK
OR-BLK
ORANGE
ORANGE
RED
RED
Lamp 1
Lamp 2
Lamp 3
Lamp 4
Lamp 5
Lamp 6
F.
Sign Ballast Catalog 2011_Rev2.0.indd 7 11/8/11 11:35 AM
Hatch Transformers, Inc.
Global Headquarters
7821 Woodland Center Blvd.
Tampa, FL 33614
P: 813.288.8006
F: 813.288.8105
www.hatchlighting.com
To view a complete Hatch
Product Catalog, scan this
barcode with your Smartphone.
Dont have a scanning App? Search the Apple App Store,
Android Market or BlackBerry App World for a barcode
scanning application
Electrical data and product specifications in this
catalog are subject to change without notice
REV: 2.0 111027
B A L L A S T S , D R I V E R S , T R A N S F O R M E R S & L A M P S F O R A L L L I G H T I N G A P P L I C A T I O N S
Sign Ballast Catalog 2011_Rev2.0.indd 8 11/8/11 11:35 AM
LANDSCAPE
TRANSFORMERS
Precision Power. Perfect Light.
R e mo t e T r a n s f o r me r s L i n e a r F l u o r e s c e n t s S i g n B a l l a s t s E l e c t r o n i c H I D L E D D r i v e r s
Hatch Landscape Transformers have
been designed from the ground up
to provide unmatched performance
for all outdoor lighting applications.
75 Watt through 1200 Watt models
are available in 12V-15V confgurations.
These transformers can be sized for
any application and can have up
to four 300 Watt circuits each with
its own circuit breaker. Toroid style
transformers are standard in our
GLT Toroid Series for enhanced
performance. Additionally, all
Landscape Transformers are
pre-wired for connection to 120VAC
GFCI protected receptacles that are
approved for wet locations. All
Landscape Transformers are fully
ETL approved to UL 1838
specifcations and are suitable for
all NEMA 3R applications.
Landscape Transformers
304 Stainless Steel enclosure
standard on all models with lifetime
warranty, providing trouble free
service
Transformers are fully epoxy
encapsulated for quiet, cool
running operation
Multi-tap outputs of 12, 13, 14, and
15 V provide the correct line voltage
at the fxture
Magnetic circuit breakers on
secondary common line for safety
Heavy duty 115 Amp rated
terminal strips for easy installation
and secure connections
Removable, lockable cover for ease
of installation and added security
Internal wiring is rated for 105C
Auto-resetting provides thermal
protection on the primary side of the
transformer
Toroid 900 & 1200 Watt
transformers include inrush current
protection to prevent nuisance
tripping of circuit breakers
Spacious wiring compartments,
multiple conduit openings and
angled terminal strips make
installation easy
Suitable for indoor or outdoor use.
Not For Use With Submersible
Fixtures
Optional Power Contactor (CNT)
enables a single switch, timer or
photcell to turn on a large quantity
of lights from one location
Optional Boost Tap (BT) available
for an additional 5-10% voltage
output on select models
All Hatch GLS & GLT Landscape Transformer Feature:
w
w
w
.
h
a
t
c
h
l
i
g
h
t
i
n
g
.
c
o
m
Certifications
Certifications
RoHS
COMPLIANT
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
GLS Series
GLT Series
GLT Toroid Series
High Effciency Toroid Core and Coil Transformer
Standard plug-in timer and photocell receptacles
304 Stainless Steel housing, optional Powder Coated models available
(i.e. add the suffx PS when ordering)
Multi-tap outputs of 12/13/14/15 volts
115 Amp terminal block
Secondary magnetic circuit breaker(s) for short circuit protection
Optional Power Contactor (i.e. add the suffx CNT when ordering)
Commercial grade inrush protection on 900 & 1200 Watt models
Standard EI Core and Coil Transformer with Standard Plug-In Timer
and Photocell Receptacles
304 Stainless Steel housing, optional Powder Coated models available
(i.e. add the suffx PS when ordering)
Multi-tap outputs of 12/13/14/15 volts
115 Amp terminal block
Secondary magnetic circuit breaker(s) for short circuit protection
Optional Power Contactor (i.e. add the suffx CNT when ordering)
Standard EI Core and Coil Transformer
304 Stainless Steel housing, optional Powder Coated models available
(i.e. add the suffx PS when ordering)
Multi-tap outputs of 12/13/14/15 volts
50 Amp terminal block standard, or optional Flying Lead models
available (i.e. add suffx FL when ordering)
Secondary magnetic circuit breaker(s) for short circuit protection
Optional Boost Tap available (i.e. add the suffx BT when ordering)
General Specifications
WWW. HATCHLI GHTI NG. COM
GLS-75
120V 12, 13, 14, 15V
75 0.63 1 11.5 5.3 5.1 D 18.7
GLS-100 100 0.83 1 11.5 5.3 5.1 D 18.7
GLS-150 150 1.25 1 11.5 5.3 5.1 D 18.7
GLS-200 200 1.67 1 11.5 5.3 5.1 D 18.7
GLS-300 300 2.50 1 11.5 5.3 5.1 D 18.7
GLS-600 600 5.00 2 11.5 5.3 5.1 D 20.2
GLS-900 900 7.50 3 13.8 7.1 5.8 E 33.8
GLS-1200 1200 10.00 4 13.8 7.1 5.8 E 38.0
GLT-300
120V 12, 13, 14, 15V
300 2.50 1 19.1 5.4 5.6 A 22.0
GLT-600 600 5.00 2 20.3 6.6 5.9 B 30.8
GLT-900 900 7.50 3 20.3 6.6 5.9 B 36.3
GLT-1200 1200 10.00 4 21.9 8.9 7.2 C 52.8
GLT -300-TD
120V 12, 13, 14, 15V
300 2.50 1 19.1 5.4 5.6 A 22.0
GLT-600-TD 600 5.00 2 20.3 6.6 5.9 B 30.8
GLT-900-TD 900 7.50 3 20.3 6.6 5.9 B 36.3
GLT-1200-TD 1200 10.00 4 21.9 8.9 7.2 C 52.8
GLS SERIES
GLT SERIES
GLT TOROID SERIES
Part Number
Voltage
Watts
Input
Amps
Output
Circuits
Dimensions (In)
Weight
(lbs)
Input Output Height Width Depth Diagram
Standard Case Material : 304 Stainless Steel
BT
CNT
PS
Black powder coated
steel enclosure
FL
Flying lead wire connections
TD
Toroid style transformer
Power contactor
Boost tap input
Models Available With:
Add Suffx When Ordering:
GLT-300-PS
P
R
E
M
I
U
M

P
R
O
D
U
C
T
GLT Toroid GLT GLS


Example
Part Number:
A
B
C
D E
Technical Diagrams
WWW.HATCHLIGHTING.COM 7821 WOODLAND CENTER BLVD, TAMPA, FL 33614 PH: 813.288.8006 FX: 813.288.8105
Height
Height
Height
Height Height
Width
Width
Width
Depth
Depth
Depth
Depth Depth
Dimensional Diagrams
Height 19.1
Width 5.4
Depth 5.6
Mounting tabs provide
for secure mount
Housing made of high
grade 304 stainless
steel
Fully epoxy encapsulated
Toroid or EI core
Standard photocell
quick connect
Standard knockouts -
on left/right side of case
for photocell mount
Standard plug-in
outlet for timer
Secondary circuit
breaker
Standard angled terminal
strips for easy wiring
Removable, lockable
front panel
Five foot outdoor rated
3-wire power cord
Height 20.3
Width 6.6
Depth 5.9
Height 21.9
Width 8.9
Depth 7.2
Height 11.5
Width 5.3
Depth 5.1
Height 13.8
Width 7.1
Depth 5.8
Dimensions
Dimensions
Dimensions
Dimensions Dimensions
PROTOCELL PLUG
TIMER MODULE
RECEPTACLE
ON
OFF
PLUG PHOTOCELL HERE
(REMOVE JUMPER)
CIRCUIT
BREAKER
COM
TAP 1
12V
TAP 2
13V
TAP 3
14V
TAP 4
15V
Width
ON
OFF
Width
ON
OFF
Precision Power. Perfect Light
Hatch Transformers
7821 Woodland Center Blvd.
Tampa, FL 33614
P: 813.288.8006
F: 813.288.8105
www.hatchlighting.com
Since 1985, Hatch has been the
recognized market leader in the design
and manufacture of premium power
lighting products and solutions. Hatch
offers a complete line of electronic and
magnetic ballasts and transformers for
virtually all lighting applications and is one
of the largest independent, full-line power
supply manufacturers in the world.
Current Hatch products include:
Electronic LED Drivers
Electronic HID Ballasts
Linear Fluorescent Ballasts
Compact Fluorescent Ballasts
Electronic Low Voltage Transformers
Remote Transformers
Magnetic HID Ballasts
Fluorescent Lamps
Sign Ballasts
To view a complete Hatch
Product Catalog, scan this
barcode with your Smartphone.
Dont have a scanning App? Search the Apple App Store,
Android Market or BlackBerry App World for a barcode
scanning application
E l e c t r o n i c T r a n s f o r m e r s M a g n e t i c H I D F l u o r e s c e n t L a m p s C o m p a c t F l u o r e s c e n t s
Hatch Transformers, Inc.
Global Headquarters
7821 Woodland Center Blvd.
Tampa, FL 33614
P: 813.288.8006
F: 813.288.8105
www.hatchlighting.com
To view a complete Hatch
Product Catalog, scan this
barcode with your Smartphone.
Dont have a scanning App? Search the Apple App Store,
Android Market or BlackBerry App World for a barcode
scanning application
Electrical data and product specifications in this
catalog are subject to change without notice
REV: 2.0 140612
B A L L A S T S , D R I V E R S , T R A N S F O R M E R S & L A M P S F O R A L L L I G H T I N G A P P L I C A T I O N S

Das könnte Ihnen auch gefallen