Sie sind auf Seite 1von 4

Connection offline

Customer statement / workshop findings Customer statement / workshop findings Customer statement / workshop findings Customer statement / workshop findings
The vehicle goes into emergency operation. The engine and glow warning light come on. The entry "P0101 air
mass meter G70- implausible signal" is logged.
Technical background Technical background Technical background Technical background
The values of the intake air temperature sender G42 and the intake air sender G31 (Duo sensor) are used to
calculate the model air mass. This makes the measured value of the air mass meter plausible.
If the values of the G42 are wrong, but within the measuring range of the sensor, the measured air mass as
implausible recognised.
-
Production change Production change Production change Production change
Measure Measure Measure Measure
The value must be similar to the outside temperature. Deviations down (e.g. to -40C), or up (e.g. 130C) are
implausible and point to a faulty Duo sensor G31/G42 for boost pressure/intake air temperature.
In this case check the Duo sensor as well as the air mass meter fault.
Check for external marks, such as green (copper) deposits and irregularities/deposits on the pins and in the
socket.
Example of temperature values:
Outside temperature = 23C -> boost air temperature about. 30-35C value correct
Outside temperature = 23C -> boost air temperature 130C value implausible
Technical product information Technical product information Technical product information Technical product information Transaction No.: 2033446/1 2033446/1 2033446/1 2033446/1
Engine in emergency operation, engine and glow warning light on Release date:29-Apr-2013
1. Note the entries on the Duo sensor. e.g. P0111- sender for intake air temperature -G42- implausible signal.
2. Note especially the temperature value Param_InletAirTempe on the 5th digit in the environmental conditions
of the entry on the air mass meter (illustration 1 and 2). Compare this value with the weather when the
entry was made.
Illustration SEQ, illustration /* Arabic: temperature value in the environmental conditions P0101 with VAS tester
Illustration SEQ, illustration /* Arabic: temperature value in the environmental conditions P0101 with Odis tester
Warranty accounting instructions Warranty accounting instructions Warranty accounting instructions Warranty accounting instructions
Service number/damage code/manufacturer: 2168 / 0040 /
Accounting with APOS: Accounting with APOS: Accounting with APOS: Accounting with APOS:
Variant 1 T5
1. Check the air mass meter and the boost air system according to the guided fault finding.
2. If the temperature value in the environmental conditions is implausible and no obvious fault can be found on
the boost air system or air mass meter, replace the Duo sensor (part numbers see Parts information). The
air mass meter can remain in the vehicle.
Variant 2 T5
Calculation of specified time
(Main operation / associated operation)
The specified time must only be used for this TPI.
Accounting with APOS/2: Accounting with APOS/2: Accounting with APOS/2: Accounting with APOS/2:
Variants Variants Variants Variants
Main Main Main Main
operation / operation / operation / operation /
associated associated associated associated
operation operation operation operation
Repair Repair Repair Repair
operation operation operation operation
Designation: Designation: Designation: Designation: TU TU TU TU
Variant 1 Variant 1 Variant 1 Variant 1
Main Main Main Main
operation operation operation operation
01500000 01500000 01500000 01500000 Guided fault finding / guided function Guided fault finding / guided function Guided fault finding / guided function Guided fault finding / guided function
*according
to EDP
Associated Associated Associated Associated
operation operation operation operation
21685599 21685599 21685599 21685599 Replace pressure sender Replace pressure sender Replace pressure sender Replace pressure sender 30 30 30 30
includes includes includes includes Loosen and attach reservoir
The repair operations include all measures according to the repair The repair operations include all measures according to the repair The repair operations include all measures according to the repair The repair operations include all measures according to the repair
instructions. instructions. instructions. instructions.
* self-diagnosis protocol
Variants Variants Variants Variants
Main Main Main Main
operation / operation / operation / operation /
associated associated associated associated
operation operation operation operation
Repair Repair Repair Repair
operation operation operation operation
Designation: Designation: Designation: Designation: TU TU TU TU
Variant 2 Variant 2 Variant 2 Variant 2
Main Main Main Main
operation operation operation operation
01500000 01500000 01500000 01500000 Guided fault finding / guided function Guided fault finding / guided function Guided fault finding / guided function Guided fault finding / guided function
*according
to EDP
Associated Associated Associated Associated
operation operation operation operation
21685599 21685599 21685599 21685599 Replace pressure sender Replace pressure sender Replace pressure sender Replace pressure sender 20 20 20 20
The repair operations include all measures according to the repair The repair operations include all measures according to the repair The repair operations include all measures according to the repair The repair operations include all measures according to the repair
instructions. instructions. instructions. instructions.
* self-diagnosis protocol
Model Model Model Model Illustration Illustration Illustration Illustration Position Position Position Position Designation Designation Designation Designation Activity Activity Activity Activity TU TU TU TU
7E
7F
STA-02 01 Guided fault finding /
guided function
00 *according
to EDP
T10-00 03 Replace pressure sender 98 30
The repair The repair The repair The repair operations include all measures according to the repair instructions. operations include all measures according to the repair instructions. operations include all measures according to the repair instructions. operations include all measures according to the repair instructions.
* self-diagnosis protocol
Model Model Model Model Illustration: Illustration: Illustration: Illustration: Position: Position: Position: Position: Designation Designation Designation Designation Activity Activity Activity Activity TU TU TU TU
Parts information Parts information Parts information Parts information
2H1S STA-02 01 Guided fault finding /
guided function
00 *according
to EDP
T10-00 02 Replace pressure sender 98 20
The repair operations include all measures according to the repair instructions. The repair operations include all measures according to the repair instructions. The repair operations include all measures according to the repair instructions. The repair operations include all measures according to the repair instructions.
* self-diagnosis protocol
The labour times are correct at the time of publication. The time units may differ slightly, if the repair The labour times are correct at the time of publication. The time units may differ slightly, if the repair The labour times are correct at the time of publication. The time units may differ slightly, if the repair The labour times are correct at the time of publication. The time units may differ slightly, if the repair
catalogue has been updated. The information in the repair operations catalogue applies Except for the open catalogue has been updated. The information in the repair operations catalogue applies Except for the open catalogue has been updated. The information in the repair operations catalogue applies Except for the open catalogue has been updated. The information in the repair operations catalogue applies Except for the open
time items (... 99). time items (... 99). time items (... 99). time items (... 99).
The necessary time for using the VAS PC tester is not included It must be accounted separately with the The necessary time for using the VAS PC tester is not included It must be accounted separately with the The necessary time for using the VAS PC tester is not included It must be accounted separately with the The necessary time for using the VAS PC tester is not included It must be accounted separately with the
print print print print- -- -out of the tester. out of the tester. out of the tester. out of the tester.
Part number of Part number of Part number of Part number of
difference pressure difference pressure difference pressure difference pressure
sensor (Duo sensor) sensor (Duo sensor) sensor (Duo sensor) sensor (Duo sensor)
Vehicle Vehicle Vehicle Vehicle Engine code Engine code Engine code Engine code
03K.906.051 Amarok CDCA, CDBA,
CNFA, CNEA
T5 CFCA
03G.906.051.E Amarok CFPA
T5 CA*
038.906.051.E T5 CJKA, CJKB