No.

Descriptions Unit 1 2 3
1 Name
2 Short-circuit Level MVA/kA
3 Acceleration time constant s
4 Secondary frequency bias MW/Hz
5 c-factor 1.00
6 R/X ratio scale 0.10
7 internal grounded impedance
- Resistance ohm
- Reactance ohm
No. Descriptions Unit 1 2 3
1 Name
2 Rate Power MVA
3 Norminal Frequency Hz
4 Rate Voltage
- HV side kV
- LV side kV
5 Vector Group
- HV side D
- LV side YN
- Phase shift deg 11
6 Pos sequ impedance
- short circuit voltage uk %
- copper loss kW
9 Zero sequ impedance, scc voltage
- Absolute uko %
- Resistive part %
10 Magnetizing Impedance
- No load Current %
- No load losses kW
11 Zero sequ. Magnetizing Imp.
- Mag. Impedance uko
- Mag. R/X ratio
12 Distribution of leackage Reactance
- x, Pos sequ. HV side pu
- x, Pos sequ. HV side pu
13 Distribution of leackage Resistance
- r, Pos sequ. HV side pu
- r, Pos sequ. HV side pu
14 Magnetizing Reactance type
- Linear yes / no
- two slope yes / no
- polynorminal yes / no
- current / flux value yes / no
15 Construction core (3-5 limb) limb 3
16 Consider Capacitance
- capacitance HV-Ground uF
- capacitance LV-Ground uF
- capacitance HV-LV, pos sequ uF
- capacitance HV-LV, zero sequ uF
17 Tap changer
- at HV / LV side HV / LV
- additional voltage per tap %
18 Internal Grounded impedance, HV side
- Resistance ohm
- Reactance ohm
No. Descriptions Unit 1 2 3
1 Name
2 Number of parallel line
3 Line Length km
4 Derating Factor
5 Line Model
- Lumped parameter yes / no
- Distributed Constant parameter yes / no
- Distributed Frequency dependent par. yes / no
6 Line type
6.A - calculated data (typLine)
A1 Rate Voltage kV
A2 Rate current kA
- rate in ground (for UG) kA
- rate in air (for UG) kA
A3 Rate Voltage kV
A4 Nominal Frequency Hz
A5 Type line OH / UG
A6 System type AC / DC
A7 Number of phase
A8 Number of neutral
A9 Parameter per unit length, 1-2 seq.
- Resistance R ohm/km
- Reactance jwL ohm/km
- susceptance B1, B2 ohm/km
- insulationi factor 0
A10 Parameter per unit length, 0 seq.
- Resistance R0 ohm/km
- Reactance jwL0 ohm/km
- susceptance B0 ohm/km
- insulationi factor 0
6.B - Tower Geometery configuration type (typGeo)
B1 Number of phase conductor
B2 Number of earth conductor
B3 phase conductor
- type solid / turbular
- Nominal Voltage kV
- Rate current kA
- Number of subconductor
- Bundle spacing m
- DC-resistance ohm/km
- GMR (equivalent radius) m
- outer Diameter m
- inner Diameter m
- skin effect yes / no
B4 Earth conductor
- type solid / turbular
- Nominal Voltage kV
- Rate current kA
- Number of subconductor
No. Descriptions Unit 1 2 3
- Bundle spacing m
- DC-resistance ohm/km
- GMR (equivalent radius) m
- outer Diameter m
- skin effect yes / no
B5 Max. seg of phase conductor m
Max. seg of Ground wires m
Earth Resistivity ohm
transpositioin yes / no
B6 Coordinate Phase wires
- Phase X1 m
- Phase X2 m
- Phase X3 m
- Phase Y1 m
- Phase Y2 m
- Phase Y3 m
B7 Coordinate Earth wires
- Earth X m
- Earth Y m
No. Descriptions Unit 1 2 3
1 Name
2 System voltage kV
3 Connection type
4 shunt type (RLC)
5 Rate Reactive Power Mvar
6 Resonace frequency Hz
7 Quality factor at fr
8 Actual Number of step
9 Maz number of step
10 Grounded impedance
- Resistance ohm
- Reactance ohm
11 Terminal to ground capacitance, per step nS
No. Descriptions Unit 1 2 3
1 Name
2 Rate voltage kVrms
3 Rate voltage Ur (phase-Neutral) kVrms
4 max continuous operating voltage Uc kVrms
5 Line charge class
6 Nominal discharge current kAp
7 I-V curve
8 Stray Capacitor uF
9 Serie inductance mH
No. Descriptions Unit 1 2 3
1 Name
2 Nominal voltage kV
3 Active Power MW
4 Power Factor