Punching Shear Check For Concourse Slab - At Construction Stage

Plunge Column
518
ISMB 300
Self Weight of concourse slab = 0.6 x 25 = 15 kN/m
2
SIDL = 6.5 kN/m
2
Live Load / Imposed Load = 10 kN/m
2
Toatl UDL = 31.5 kN/m
2
Effective area of slab being supported by column = 160 m
2
ULS load factor = 1.3
ULS load to be considered for punching shear = 160 x 31.5 x 1.3 = 6552 kN
Punching Shear Check at 'd/2' from support face:
Maximum net load on column = 6552 kN
Finished size of plunge column = 1080 mm x 480 mm
Overall thickness of concourse slab = 600 mm
Effective depth of base slab = 518 mm
Grade of concrete of base slab = 35 MPa
Provided structural steel section to increase shear capacity = ISMB 300 of grade 250 MPa
Web area of steel section (Tw * D) = 2250 mm
2
Provided numbers of steel section at critical shear plane = 4 nos.
Total area of structural steel 9000 mm
2
Shear capacity of provided structural steel = 0.6 x 250 x 9000 N
= 1350 kN
Shear force to be taken by concrete section = 5202 kN
Permissible Punching shear stress (cl. 31.6.3 IS:456) = 1.5 x 0.25 x 35
= 2.219 MPa
Perimeter for shear at 'd/2' from column face = 5192 mm
Calculated punching shear stress =V / (b x d) = 1.934 MPa < 2.219 MPa
OK
Calcul ati on for Punchi ng Shear Reinforcement:
Provided reinforcement to resist punching shear = 16 mm diameter @ 150 mm x @ 300 mm
Length of structural steel section from face of column = 259 mm ('d/2' distance)
Length of perimeter at end of steel section = 5192 mm
Capacity of provided shear reinforcement, V
us
=0.87 x f
y
x A
sv
x d / S
v
Nos. of legs of shear reinforcement at perimeter = 35 nos.
Provided area of steel, A
sv = 7037
mm
2
Spacing of reinforcement, S
v = 300 mm
Capacity of shear reinforcement, V
us = 4387 kN
Capacity of concrete, V
c
=0.5 x
c
x b x d = 1989 kN
Total shear carrying capacity of the section = 4387 +1989 = 6376 kN
> 5202 kN OK
Hence, provide 4 nos.ISMB 300 extending minimum 518mm from face of column
ISMB 300
Welded to
Steel Plunge Col.
Punching Shear Check For Concourse Slab - At Permanent Stage
Plunge Column
Permanent Column
Self Weight of concourse slab = 0.6 x 25 = 15 kN/m
2
SIDL = 6.5 kN/m
2
Live Load / Imposed Load = 10 kN/m
2
Toatl UDL = 31.5 kN/m
2
Effective area of slab being supported by column = 160 m
2
ULS load factor = 1.5
ULS load to be considered for punching shear = 160 x 31.5 x 1.5 = 7560 kN
Punching Shear Check at 'd/2' from support face:
Maximum net load on column = 7560 kN
Finished size of plunge column = 1800 mm x 1000 mm
Overall thickness of concourse slab = 600 mm
Effective depth of base slab = 518 mm
Grade of concrete of base slab = 35 MPa
Provided structural steel section to increase shear capacity = ISMB 300 of grade 250 MPa
Web area of steel section (Tw * D) = 2250 mm
2
Provided numbers of steel section at critical shear plane = 0 nos. (Neglected in permanent stage)
Total area of structural steel 0 mm
2
Shear capacity of provided structural steel = 0.6 x 250 x 0 N
= 0 kN
Shear force to be taken by concrete = 7560 kN
Permissible Punching shear stress (cl. 31.6.3 IS:456) = 1.5 x 0.25 x 35
= 2.219 MPa
Perimeter for shear at 'd/2' from column face = 7672 mm
Calculated punching shear stress =V / (b x d) = 1.902 MPa < 2.219 MPa
OK
Calcul ati on for Punchi ng Shear Reinforcement:
Provided reinforcement to resist punching shear = 16 mm diameter @ 150 mm x @ 300 mm
Length of structural steel section from face of column = 259 mm ('d/2' distance)
Length of perimeter at end of steel section = 7672 mm
Capacity of provided shear reinforcement, V
us
=0.87 x f
y
x A
sv
x d / S
v
Nos. of legs of shear reinforcement at perimeter = 51 nos.
Provided area of steel, A
sv = 10254
mm
2
Spacing of reinforcement, S
v = 300 mm
Capacity of shear reinforcement, V
us = 6392 kN
Capacity of concrete, V
c
=0.5 x
c
x b x d = 2939 kN
Total shear carrying capacity of the section = 6392 +2939 = 9331 kN
> 7560 kN OK