Sie sind auf Seite 1von 20

Aluminium Residential Technical Size Manual

As one of the largest privately owned and operated manufacturers


of windows and doors, our commitment is focused on meeting the
many and varied needs of architects, builders and homeowners.
We do this through our Customer Commitment and Care Values:
Quality of design and manufacture using the very latest
techniques and technology
Using only the highest grade of materials
Quality Control at every stage
Exceeding the standards of relevant Australian building
authorities
Research and development that allows us to be at the forefront
of design and innovation
Real pride in the products we offer and the way they are made
Value for money
Backing our products with a 10 year written guarantee
Being in touch with our customer needs and expectations
Being a member of the Housing Industry Association (HIA)
Ensuring our windows are continually tested by the Council of
National Association of Testing Authorities (NATA)
To give you absolute peace of mind.
Wideline, Smart Choice!
Aluminium Options 2
Aluminium Windows 3-6
Aluminium Doors 7-9
Aluminium Doors/Frames 10
Installation Details Windows 11-13
Installation Details Entry Frames 14
Installation Details Doors 15-16
More and more builders are choosing Wideline.
Index
a. The product has been installed in accordance w ith the relevant
A ustralian Standards and recognised building practice.
b. The product has been m aintained in accordance w ith industry
recom m endations.
c. The product has not been subject to m isuse, physical abuse or neglect.
d. M anufacturing standards and tolerances are not deem ed defects,
nor are industry variations in the colour of alum inium and tim ber
com ponentry.
e. W ideline accepts no responsibility for glass breakage (except for
faulty w orkm anship or m aterials). W ire reinforced glass, toughened
glass, oat glass, lam inated glass and m irror glass is guaranteed against
defects and degradation for a period of three (3) years.
f. M oving parts w hich w ear out as a part of norm al use are guaranteed
for three (3) years.
g. This guarantee is lim ited to the repair or replacem ent of the faulty
product at the com panys discretion but does not extend to the
installation or re nishing of a replacem ent product.
h. Finish failures or corrosion of alum inium or other com ponents
due to environm ental conditions such as air pollutants, acid rain or
other corrosive substances are defects w hich have arose due to the
conditions and are therefore not the responsibility of W ideline.
i. C orrosion, w ear, or failure of standard com ponents in seacoast
applications (w ithin 5 kilom etres of coastal w aters) is not covered
under this w arranty as deterioration is possible under clim ate
conditions.
j. N orm al w ear or discolouration of nishes including the tarnishing of
brass is a result of conditions or applications and are therefore not the
responsibility of W ideline.
k. O nly repairs carried out by W ideline personnel or authorised
W ideline agents are covered by this guarantee.
l. C laim s under this guarantee should be m ade w ithin one m onth of the
defect arising in the product. C opies of docum entation show ing the
purchase date of the product should be included w ith your w ritten
claim and forw arded to the nearest W ideline of ce.
This guarantee is in addition to all other rights and rem edies in respect of
this product to w hich you are entitled under the Trade Practices A ct and
sim ilar State and Territory law s.
For the benet of the consumer
Wideline Guarantee
Installation and Maintenance
Your Wideline products are guaranteed against defects arisingfromfaulty
workmanship or materials for a period of ten (10) years fromthe date of
deliverybyWideline, subject to the followingconditions:
Wideline products are manufactured fromthe most suitable materials and
nishes available and when properlymaintained, will give manyyears of
qualityservice.
Builders/Home Owners Please Note
W hen you are installing w indow s and doors there are som e precautions
you should take to ensure that the products w ill retain their ex-factory
condition until installation is com plete and the job handed over.
W ideline products usually arrive on the site in a fully nished condition.
H ow ever, they can be dam aged through careless handling, and are
particularly vulnerable w hen being installed in brick or concrete block
construction.
Remember
Keep w et cem ent, m ortar and brick-cleaning acid from contact w ith
tim ber or alum inium (particularly if the nish is anodised), before,
during and after installation.
If accidentally splashed, w ash off im m ediately w ith clean w ater
otherw ise perm anent staining or dam age m ay occur.
D o not use acid to rem ove m ortar stains on w indow fram es.
H ose dow n brickw ork to rem ove residual cleaning acid that m ay leach
out and cause dam age to the nish later.
D o not place w indow s directly onto green concrete slabs.
Keep the tracks of sliding w indow s and doors clear of sand and cem ent
droppings.
D o not use w indow or door fram es to support planks or tem porary
scaffolding.
C lean up w hen the job is com plete w ith m ild detergent and rinse w ith
clean w ater.
AluminiumProducts
A good general rule is that alum inium should be w ashed to rem ove dirt
deposits as often as it is necessary to w ash w indow s.
A lum inium requires only m inim um m aintenance but, like your m otor car,
the nish m ay deteriorate if dirt, w hich collects on the surface, is allow ed
to rem ain unw ashed over a period of tim e. This is because dirt absorbs
m oisture present in the atm osphere. M oisture can contain salt near the
ocean or other im purities in industrial areas, and it is the com bination of
dirt and contam inated m oisture that can cause deterioration of alm ost
any surface nish.
In rural areas w here norm ally there is very little contam inated m oisture,
you m ay not need to clean your alum inium ttings m ore than every six
m onths. In industrial and coastal areas, w ashing at intervals of one to three
m onths m ay be required or even m ore frequently in locations close
to the ocean or in heavily polluted industrial areas, especially w here the
w indow s or other product is sheltered from the w ashing effects of the rain.
To clean alum inium , use the m ildest treatm ent you can w hich produces
satisfactory results. Start w ith w arm w ater, w ith soap or detergent. O n
anodised m aterial try solvent cleaners (eg: kerosene, turpentine, w hite
spirit), or non-etching chem ical cleaners, or a w ax-based polish cleaner.
N ever use harsh liquid chem icals, abrasive cleaners or steel w ool.
Glass
To clean clear oat glass, w ipe over the surface w ith a few drops of
m ethylated spirits on a dam p cloth, and then polish the surface dry w ith
a lint free cloth. Proprietary glass cleaners are not recom m ended as som e
of them can cause dam age to the silver backing on m irrors and the interlay
of lam inated glass. Ensure that all cleaning cloths are free of any abrasive
substances.
A void causing extrem e tem perature changes as this m ay lead to therm al
fracture of the glass (i.e. do not direct hot or cold w ater onto glass).
General I nformation
1
Wideline are a founding member of the Australian Window Association (AWA) and as part of that
membership are required to supply products that have been tested to meet Australian Standards AS 2047
(windows in buildings) and AS 1288 (glass in buildings).This testing has been conducted by third party NATA
approved certifiers and our products are constantly audited by the AWA to ensure compliance.Varying
structural and water carrying capacities as stipulated in AS 2047 can be achieved by our range of products
depending on site requirements.
The inclusion of energy requirements of building materials in the Australian Building Code is a growing project
that has encompassed the window industry.Wideline in reaction to this market trend have had our windows
energy rated through the AWA run Window Energy Rating Scheme (WERS).Varying glazing options from clear
float glass through to high performance double glazing products have been tested to give a spectrum of results
and energy efficiencies.
Acoustics is another area where Wideline have been highly focused. Councils and building designers are
becoming increasingly demanding with the acoustic requirements that windows and doors have to perform in
the building envelope.Wideline have had CSIRO testing completed on a range of products to give accurate
performance levels as required. It is a common misconception that double glazing is the solution for acoustic
attenuation.We have found through testing that monolithic (single layer or laminated) glass can perform to
equivalent levels at a reduced cost.
Please keep in mind that windows and doors are delivered in a finished state and therefore it is important to
protect the windows and doors as paint work, hardware and glass can be damaged during construction.
Optional extras available include:

Wideline Protec,Widelines own brand of plastic wrap is available for all windows and doors. It is
recommended that the plastic wrap is removed during brick cleaning or at the completion of rendering as
prolonged adhesion to the glass can leave a sticky residue.

Insect and safety screensare available for our product range (apart from the bi-fold door which cannot
be screened).Various mesh types available fibreglass standard, aluminium, stainless steel and one way
privacy mesh.

Key locksare available for all windows and doors.These locks can also be keyed alike.

Various hardware finishesfor all products are available.There are a number of colours other than black,
which can be colour matched to your desired products. Entry, bi-fold and sliding door handles are also
available in various finishes such as satin chrome.

Range of glass optionsthat cover security,safety,energy,acoustic and aesthetic requirements are available.

Wide range of coloursis offered which includes twelve standard colours alongwith twelve secondary colours.

Various sill capacitiesare available with all products being available in the standard 150 Pascal water
carrying capacity sill along with a 300 Pascal sill for those areas exposed to high wind and water pressure.

Semi-commercial aluminium entry frame material can surround all products within our range.
Standard size windows will have an additional 74mm added to the overall window size. For example, an
AS1416 inserted into our entry frame will have an overall size of 1444 (h) x 1644 (w).
2
Widelines policy of continued improvement may result in a change of specification without notice.
Aluminium Options
Aluminium Window and Door Bar Layouts
Special Shapes Large array of special shapes available on request
Sunburst Hexagonal Octagonal
Rake
Minimumheight of rake vertical
side is recommended at 150mm.
Porthole Rake with mullion
Minimumheight of rake vertical
side is recommended at 150mm.
Heritage Layout
Standard Colonial Bar Endeavour Bar Montgomery Bar Individually Glazed
Colonial Bar
(Hinged doors only)
M
i
n

1
5
0
m
m
M
i
n

1
5
0
m
m
M
i
n

5
5
0
m
m

D
i
a
m
e
t
e
r
Diamond Head Federation Layout Colonial Layout
Variations in Heritage/Federation Layouts
Bar Layouts available in:
3
Widelines policy of continued improvement may result in a change of specification without notice.
Reveal I nformation
Reveal Application Breakdown
80m m 70m m steel or tim ber fram e 70m m stud-gyprock interior
w eatherboard exterior
100m m 90m m steel or tim ber fram e 90m m stud-gyprock interior
w eatherboard exterior
117m m 230m m brick veneer 70m m stud/40m m cavity brick
veneer
135m m 250m m brick veneer 90m m stud/40m m cavity brick
veneer
165m m 270m m double brick 50m m cavity brickw ork
(M eranti only)
Storm m oulds 270m m double brick 50m m cavity brickw ork
D ouble brick lugs
Single brick lugs 110-220m m brickw ork 110 single brickw ork
220 pier brickw ork
blockw ork
Reveal Size Chart
Reveals are available in Meranti and finger jointed primed pine according to the following table.
Reveals available in Meranti
and Finger Jointed Pine.
OUTER BRICKWORK
R
E
V
E
A
L
STUD
52mm Window suites
(Sliding,Awning,Double Hung)
40MM CAVITY
1
3
5
1
1
5
3
0
1
0
9
0
4
0
1
1
0
2
5
0
Stacker Door
(Includes flydoor frame)
OUTER BRICKWORK
R
E
V
E
A
L
40MM CAVITY
1
3
5
1
1
5
8
9
1
0
9
0
4
0
1
1
0
2
5
0
Sliding Door
Entry Frame
OUTER BRICKWORK
R
E
V
E
A
L
40MM CAVITY
1
3
5
1
1
5
3
0
1
0
9
0
4
0
1
1
0
2
5
0
OUTER BRICKWORK
R
E
V
E
A
L
40MM CAVITY
1
3
5
1
1
5
6
6
1
0
9
0
4
0
1
1
0
2
5
0
10mm
Packer
STUD
10mm
Packer
STUD
10mm
Packer
STUD
10mm
Packer
Wall Sections
The following diagrams show reveal size and window placement for Brick Veneer construction.
N ote:
The dim ensions w hich appear on
your quotation are for the actual
alum inium fram e size.Reveals are
additional to the w indow fram e
size (19m m thick each side).
A surcharge applies to non-
standard reveal sizes.
4
Widelines policy of continued improvement may result in a change of specification without notice.
AA T2024 AA T2022 AA T2018
AA T1824
AA T2016
AA T1822 AA T1818
AA1524 AA1527 AA1522 AA1518
AA1422 AA1427 AA1424 AA1412 AA1418
AA T2012 AA T2009
AA T1816 AA T1812 AA T1809
AA1516
AA T1806
AA1416
AA1512
AA1409
AA1506 AA1509
AA T2006
AA1406
AA T1827
AA1227 AA1224 AA1222 AA1218
AA1027 AA1024 AA1022 AA1018
AA0927 AA0924 AA0922 AA0918
AA1216 AA1212 AA1209 AA1206
AA1016 AA1012 AA1009 AA1006
AA0916 AA0912 AA0909 AA0906
AA0616 AA0612 AA0609 AA0618 AA0622 AA0624 AA0627
2
0
5
0

2
1
1
0

1
8
0
0

1
8
6
0

1
4
6
0

1
5
2
0

1
3
7
0

1
4
3
0

1
2
0
0

1
2
6
0

1
0
3
0

1
0
9
0

8
6
0

9
2
0

6
0
0

6
6
0

2650
2710
2410
2470
2170
2230
1810
1870
1570
1630
1210
1270
850
910
610
670
AA0606
680
1370
1200
600
AA T2027
S
T
U
D

O
P
E
N
I
N
G

F
R
A
M
E

Aluminium Windows
Awning Windows
Paragon Introduction
The window market is now demanding products that meet the emerging
energy requirements and the increase in custom designed development.
The solution is Paragon.
Paragon is the new Wideline range of semi-commercial products (100mm
suite) specifically designed to be modular, functional and aesthetically suited to
varying applications.
The Main Frame is the heart of the Paragon range that allows flexibility in
design.The frame is 100mm x 40mm with centre pocket glazing functionality.
The entire Paragon range (excluding Louvres) can be glazed with up to 24mm of glass or be individually
colonial glazed 3m high doors can be achieved with our heavy duty door panels.The panels are common for
bi-folds, sliding, stacking and entry doors to standardise the look for the whole building design.
Maximise your view with large Awning or Casement sashes with quality hardware and double compression
seals. Combinations with fixlites, louvres and other products in the range can be achieved through the use of
various Paragon couplers.
If your application involves Acoustics, Energy, Bushfire hazards or Extreme Weather performance Paragon is
your solution.
5
Widelines policy of continued improvement may result in a change of specification without notice.
2
1
4
0
2
1
0
0
2
1
4
0
2
1
0
0
2410
2470
1570
1630
AD1506
AD1406
AD1206
AD1006
AD0906
ASDC2124 ASDC2116
AD1827
AD2027
AD0927
AD1027
AD1227
AD1427
AD1527
AD1824
AD2024
AD0924
AD1024
F
R
A
M
E
S
T
U
D

O
P
E
N
I
N
G
AD1224
AD1524
AD1822
AD2022
AD0922
AD1222
AD1022
AD1422
AD1522
AD1818
AD2018
AD0918
AD1018
2
0
5
0
2
1
1
0
1
8
0
0
1
8
6
0
1
4
6
0
1
5
2
0
1
3
7
0
1
4
3
0
1
2
0
0
1
2
6
0
1
0
3
0
1
0
9
0
8
6
0
9
2
0
2650
2710
2410
2470
2170
2230
1810
1870
1570
1630
1210
1270
850
910
610
670
AD1418 AD1424
AD1009
AD1518
AD1816
AD2016
AD1209 AD1218
AD0916 AD0912
AD1016
AD1416
AD1216
AD1516
AD1812
AD2012
AD1012
AD1212
AD1509
AD2006
AD1512
AD1809
AD2009
AD0909
AD1409 AD1412
AD1806
F
R
A
M
E
S
T
U
D

O
P
E
N
I
N
G
ASDC2135
ASDC2118
1870
1810
ASDC2122
2170
2230
ASDC2132 ASDC2136
3570
3630
2710
2770 3310
3250 3610
3670
ASDC2127
F
R
A
M
E
S
T
U
D

O
P
E
N
I
N
G
Aluminium Windows
Double Hung Windows
Window and Door Combinations
Notes:
1. Sliding doors are available with hardwood sill, note that stud opening height increases by 30mm.
2. Standard sliding door combination frames are available with sliding flydoors only. Safety doors are not compatible.
3. Sliding doors and flydoors slide on the outside.
4. Combination is only available with the double hung window.
670 910 1270 1630 1870 2230 2470 2710
2650 2410 2170 1810 1570 1210 850 610
2
1
9
4
2
0
1
4
1
8
6
4
1
5
6
4
1
4
7
4
1
2
0
4
1
0
2
4
9
3
4
6
6
4
6
0
4
8
7
4
9
6
4
1
1
4
4
1
4
1
4
1
5
0
4
1
7
7
4
1
9
5
4
2
1
3
4
ALV ALV ALV ALV ALV ALV ALV ALV
ALV ALV ALV ALV ALV ALV ALV ALV
ALV ALV ALV ALV ALV ALV ALV ALV
ALV ALV ALV ALV ALV ALV ALV ALV
ALV ALV ALV ALV ALV ALV ALV ALV
ALV ALV ALV ALV ALV ALV ALV ALV
ALV ALV ALV ALV ALV ALV ALV ALV
ALV ALV ALV ALV ALV ALV ALV ALV
ALV ALV ALV ALV ALV ALV ALV ALV
0606 0609 0612 0616 0618 0622 0624 0627
0906 0909 0912 0916 0918 0922 0924 0927
1006 1009 1012 1016 1018 1022 1024 1027
1206 1209 1212 1216 1218 1222 1224 1227
1406 1409 1412 1416 1418 1422 1424 1427
1506 1509 1512 1516 1518 1522 1524 1527
1806 1809 1812 1816 1818 1822 1824 1827
2006 2009 2012 2016 2018 2022 2024 2027
2106 2109 2112 2116 2118 2122 2124 2127
6
3
4
9
1
4
1
0
5
4
1
1
9
4
1
4
7
4
1
6
1
4
1
8
9
4
2
0
3
4
2
1
7
4
5
7
4
8
5
4
9
9
4
1
1
3
4
1
4
1
4
1
5
5
4
1
8
3
4
1
9
7
4
2
1
1
4
1
0
2
m
m

B
L
A
D
E

O
P
T
I
O
N
1
5
2
m
m

B
L
A
D
E

O
P
T
I
O
N
S
T
U
D

O
P
E
N
I
N
G
F
R
A
M
E
S
T
U
D

O
P
E
N
I
N
G
F
R
A
M
E
Aluminium Windows
6
Widelines policy of continued improvement may result in a change of specification without notice.
Louvre Windows (102mm and 152mm blades)
Notes:
1. A choice of glass blades,Western Red Cedar blades or extruded aluminium blades are available in two sizes 102mm and
152mm in height, with spans up to 900mm per blade.
2. Each louvre blade is secured by unique injection-moulded clips that are silent, provide a weather-tight seal and corrosion free.
3. Wideline louvres can be fitted with integrated face fixed insect screens without interference to the operation of the louvre galleries.
4. Maximum wind loading 1500 Pa (dependant on blade width). Maximum water resistance performance 200 Pa.
5. Laminated Glass is not to be used in Louvre windows.
6. Louvre galleries,handles and clips are coloured black or white as standard but can be ordered in a range of powder-coat colours.
7. Handle fitted as standard to left hand side (as viewed from the outside), however can be reversed if specified.
8. The louvre windows shown above indicate the number of 152mm blades for any given size.
9. Example of codes:102mm =ALV102-2124, 152mm ALV152-2124.
Aluminium Windows
7
Widelines policy of continued improvement may result in a change of specification without notice.
Colonial, Endeavour Bars
1
0
3
0
1
0
9
0
1
4
3
0
1
3
7
0
1
2
0
0
1
2
6
0
6
0
0
6
6
0
9
2
0
8
6
0
AK1224
AK1222
AK1422
AK1424
AK1022
AK1024
AK1227
AK1427
AK1027
AK0922
AK0622
AK0924
AK0624
2230
2170 2410
2470
AK0627
AK0927
2710
2650
AK1527
AK1827
AK2027
AK1822
AK2022
AK1522 AK1524
AK1824
AK2024
680
1370
1200
600
1
5
2
0
2
1
1
0
2
0
5
0
1
8
6
0
1
8
0
0
1
4
6
0
2650
2710 2230
2170
2470
2410
S
T
U
D

O
P
E
N
I
N
G
F
R
A
M
E
S
T
U
D

O
P
E
N
I
N
G
F
R
A
M
E
AFAST1806
AFAS1506
AFAS1406
AS0609 AS0612 AS0616 AS0618 AS0622 AS0624 AS0627
AS0906 AS0927 AS0924 AS0922 AS0918 AS0916 AS0912 AS0909
AS1006 AS1027 AS1024 AS1022 AS1018 AS1016 AS1012 AS1009
AFAS1206 AS1227 AS1224 AS1222 AS1218 AS1216 AS1212 AS1209
AS1427 AS1424 AS1422 AS1418 AS1416 AS1412 AS1409
AS1527 AS1524 AS1522 AS1518 AS1516 AS1512 AS1509
AST1827 AST1824 AST1822 AST1818 AST1816 AST1812 AST1809
AFAST2006 AST2027 AST2024 AST2022 AST2018 AST2016 AST2012 AST2009
670
610
910
850
1270
1210
1630
1570
1870
1810
2230
2170
2470
2410
2710
2650
6
6
0
6
0
0
9
2
0
8
6
0
1
0
9
0
1
0
3
0
1
2
6
0
1
2
0
0
1
4
3
0
1
3
7
0
1
5
2
0
1
4
6
0
1
8
6
0
1
8
0
0
2
1
1
0
2
0
5
0
AS0606
1200
600
1370
680
S
T
U
D

O
P
E
N
I
N
G
F
R
A
M
E
Sliding Windows
Servery Sliding Windows
Colonial and Montgomery Bars are best used
on sliding windows.
Endeavour Bars are not compatible.
8
Widelines policy of continued improvement may result in a change of specification without notice.
3576
3636
3216
3276
2676
2736 2376
2316
4582
4642
5302
5362
2
1
1
0
2
1
5
0
2
1
1
0
2
1
5
0
ASSD2123 ASSD2127 ASSD2132 ASSD2136
ASSD2146 ASSD2153
S
T
U
D

O
P
E
N
I
N
G
F
R
A
M
E
S
T
U
D

O
P
E
N
I
N
G
F
R
A
M
E
Sliding Door
Stacking Sliding Door
Notes:
1. Sliding doors are available with hardwood sill, note that stud opening height increases by 30mm.
2. Standard sliding door frames are 100mm wide, stacking sliding door frames are 162mm wide
(includes flydoor frame).
3. Standard sliding door frames are available with sliding safety or flydoors.
4. For sliding doors, the inclusion of a 300pa sill increases overall height by 39mm.
Aluminium Doors
ASDI2122
2170
2230
2
1
5
0
2
1
1
0
2
1
5
0
2
1
1
0
ASDI2132
ASDI2118
3250
3310
ASDI2116
1810
1870
1570
1630
ASDI2135
3580
3640
ASDI2136
ASDI2124
3610
3670
ASDI2127
2410
2470
2710
2770
S
T
U
D

O
P
E
N
I
N
G
F
R
A
M
E
S
T
U
D

O
P
E
N
I
N
G
F
R
A
M
E
9
Widelines policy of continued improvement may result in a change of specification without notice.
Aluminium Doors
2
0
9
5
2
0
9
5
5150
1730
ABF2117 ABF2126
ABF2152 ABF2160
ABF2135 ABF2143
2615 3460
6000
4300
1790 2675 3520 4360
2
1
3
5
2
1
3
5
6060 5210
*2L 2L1R
3L
3L1R
*4L
4L1R
3L2R
5L
3L3R 7L
4L3R
5L2R
5L1R
S
T
U
D

O
P
E
N
I
N
G
F
R
A
M
E
S
T
U
D

O
P
E
N
I
N
G
F
R
A
M
E
Bi-fold Doors
Notes:
1. Door configurations with even numbers of panels on each side (examples shown above with *) do not come with
entry handles, hence have internal access only.
2. Each configuration can be mirror imaged, other configurations available on request.
3. Maximum frame width =6000mm
Standard frame height =2095mm
Maximum frame height =2400mm @ 700pa (N2)
Maximum leaf width =900mm
Maximum leaf weight =45kg
Outer frame section size =100mm
4. Stud opening size shown applies to frames fitted with reveals for brick veneer applications.
5. Please refer to recommended installation details on page 15.
S
T
U
D

O
P
E
N
IN
G
F
R
A
M
E

S
IZ
E
S
T
U
D

O
P
E
N
IN
G
F
R
A
M
E

S
IZ
E
S
T
U
D

O
P
E
N
IN
G
F
R
A
M
E

S
IZ
E
10
Widelines policy of continued improvement may result in a change of specification without notice.
E
N
T
R
Y

F
R
A
M
E

S
IZ
E
D
O
O
R

S
IZ
E
E
N
T
R
Y

F
R
A
M
E

S
IZ
E
D
O
O
R

S
IZ
E
Entry Doors
Entry Frames
Notes:
Colonial bar
doors have
individual panels
(not glue on bars).
FP (fielded panels)
are available.
Notes:
Door hinging shown for
clarity only, doors are
separate items.
Safety doors, flydoors
and insect screens are
available on entry
frame suites.
Stud opening size shown
applies to frames fitted
with reveals for brick
veneer applications.
Refer installation details
on page 16.
Aluminium Doors/Frames
11
Widelines policy of continued improvement may result in a change of specification without notice.
Timber Entry Frames
S
T
U
D

O
P
E
N
IN
G
F
R
A
M
E

S
IZ
E
S
T
U
D

O
P
E
N
IN
G
F
R
A
M
E

S
IZ
E
S
T
U
D

O
P
E
N
IN
G
F
R
A
M
E

S
IZ
E
2
1
0
5
2
1
0
5
2
1
0
5
1450 1450 1690 1690
1470 1470 1710 1710
1300 1300 1725 2540
1320 1320 1745 2560
868
888
MDF8
1680
1700
MDF16
875
1210
1230
MEF12R
875
1210
1230
MEF12L
MLF14R MLF14L MLF16L MLF16L
MUE13R MUE13L MUE17 MUE25
8
6
0
875
875 875 875
1
3
7
0
1690
1710
MEF16
880
875
875 880 1690
8
6
0
Notes:
1. When supplied with sill, frame height increases to 2095.
2. Hand of frame determined by fixed light as viewed from outside, R-Right hand L-Left hand.
3. All frames are designed to accommodate a standard 2040 x 820 door.
4. MUE sidelites are designed to accommodate standard 400 wide panels.
5. Outside frame is 31mm thick. Internal door jambs are 38mm.
6. Western Red Cedar Entry Frames are available. See Technical Size Manual (Cedar) for details and specifications.
Meranti Frames
12
Widelines policy of continued improvement may result in a change of specification without notice.
10mm clearance
TRIMMER
PACKING BY BUILDER
FLASHING BY BUILDER
FLASHING BY WIDELINE
FACTORY FITTED
REVEAL LINING
BY WIDELINE
BY BUILDER
ARCHITRAVE
REVEAL LINING
FLASHING
OVER
BUILDER
BY
BY WIDELINE
FACTORY FITTED
20mm clearance
WEATHER
BOARD
10mm clearance
PACKING BY BUILDER
ARCHITRAVE BY BUILDER
STUD
BY
BUILDER
PACKING
FACTORY FITTED
BUILDER
BY
ARCHITRAVE
TRIMMER
BY BUILDER
BY BUILDER
FLASHING
FIXING LUG
AG-909
HEAD ELEVATION
BY BUILDER
QUAD
EAVES LINING
BY WIDELINE
REVEAL LINING
20mm clearance
FLASHING
HEAD
FACTORY
STUD
BUILDER
PACKING BY
40mm clearance
OUTER BRICKWORK
AG-814 FIXING LUG
BY WIDELINE
IF REQUIRED
STORM MOULD
RENDER
FITTED
WIDELINE
BY
JAMB PLAN VIEW
BRICK SILL
COMPENSATING APRON
SILL ELEVATION
BY WIDELINE
BRICK SILL
FLASHING
REVEAL
LINING
BUILDER
ARCHITRAVE BY
APRON
COMPENSATING
BUILDER
ARCHITRAVE
BY
ARCHITRAVE SILL
BUILDER
BY
BY WIDELINE
FACTORY FITTED
REVEAL LINING
SILL ELEVATION
JAMB PLAN VIEW
HEAD ELEVATION
SILL ELEVATION
JAMB PLAN VIEW
HEAD ELEVATION
WEATHERBO
OPTIONAL WIDELINE CLADDING TRIM
ARD
HEAD
TRIMMER
Brick Veneer Double Brick Weatherboard
Notes:
1. All standard windows are delivered to site fully assembled and ready for installation.
2. Available in a variety of finishes and colours with the latest developments in painted polyester powder coats.
3. Wideline windows are designed to suit brick veneer, cavity brick, single brick and timber frame construction.
4. Wideline stress the importance of builder flashing between windows and the structure.
5. Vertical flashing of windows should be used for lap-clad construction.
6. Adjustable storm moulds for prepared openings are available for all windows and doors in all finishes for fitting
prior to installation.
I nstallation Details Windows
Sliding, Double Hung, Awning
13
Widelines policy of continued improvement may result in a change of specification without notice.
I nstallation Details Windows
90 and 135 Bay Windows
52
52
STUD
90 STUD OPENING SIZE 90
=CENTRE FRAME-215
CENTRE FRAME SIZE
RETURN
WING
52
REVEAL
RETURN WING TO
BE 10mmCLEAR OF
FACIA BOARD
O/A
10
BRICKWORK
2
5
0
B
R
I
C
K

P
R
O
J
E
C
T
I
O
N
=

R
E
T
U
R
N
W
I
N
G
+
1
3
2
OVERALL BRICKWORK =CENTRE FRAME+264
STUD OPENING SIZE=CENTREWINDOW +1035
BRICK OPENING SIZE=CENTREWINDOW +953
CENTREWINDOW FRAME
BRICK
STUD
R
E
T
U
R
N
W
IN
D
O
W
=
6
1
0
135
SLAB&BRICKWORK =CENTREWINDOW +131
BAY COUPLING
BY WIDELINE
REVEAL LINING
BY WIDELINE
CENTREWINDOW FRAME+63
2
5
0
5
3
8
.
3

B
R
I
C
K
T
O

B
R
I
C
K
1
1
0
4
0
9
0
1
0
Notes:
1. Available in various bar layouts.
2. 90 and 135 bay window available in all standard window configurations using special or standard sizes.
3. Insect screens available for all opening sashes.
4. For quoting purposes the measurement is taken as if the two return windows were flat
ie:middle window 1210 +two return windows 610 =2430.
5. The standard return window width is 610mm. Special return window widths may be ordered.
These details are common for brick veneer construction and are not intended to cover all variations in use.
Dimensions are based on 138mm reveal size.
135 Bay Window
90 Bay Window
14
Widelines policy of continued improvement may result in a change of specification without notice.
JAMB PLAN VIEW
HEAD ELEVATION
JAMB PLAN VIEW
FLASHING BY BUILDER
RENDER
HEAD ELEVATION
JAMB PLAN VIEW
HEAD ELEVATION
SILICONE
FLASHING BY
BUILDER
ARCHITRAVEBY BUILDER
PACKER IF REQUIRED BY
BUILDER SHOULD BE
APPROXIMATELY 10mmTHICK.
SECONDARY FIXING CAN
BEDONETHROUGH
REVEAL INTO STUD
FIXING THROUGH JAMB
ISRECOMMENDED,JAMB
ADAPTOR ISREMOVABLE
TO CONCEAL SCREW HEADS.
R
E
V
E
A
L
STUD
OUTER BRICKWORK
LINTEL
NAIL REVEAL TO
HEAD TRIMMER AT
MAXIMUM 600CRS.
ARCHITRAVE
BY BUILDER
ANGLEBY
BUILDER
REVEAL
INNER BRICKWORK
INNER
OUTER BRICKWORK
LINTELS
DOUBLEBRICK LUG
AG-10.814MINIMUM
OF 4PER JAMBAT
MAX 600CRS.
ANGLEBY
BUILDER
OUTER
REFER NOTE9
1
1
3

G
A
P

I
N

F
R
A
M
E
35
GYPROCK
QUAD
HEAD TRIMMER
QUAD
PACKER
TO SUIT
35x45STUD
90x45STUD
WEATHERBOARD
SILICONE
G
Y
P
R
O
C
K
W
E
A
T
H
E
R
B
O
A
R
D
BRICKWORK BRICKWORK
BRICKWORK
OUTER
HEAD TRIMMER
GYPROCK
SILL ELEVATION OPEN OUT
SILL ELEVATION OPEN IN
SLOTS PUNCHED IN SILL TO ALLOW
WATER DRAINAGE FROM FRAME
DRAINAGE AREA
REFER NOTE 6 FLASHING BY BUILDER
FLOOR COVERING
SILL TILE
R
E
V
E
A
L
3
9
1
7
FLOOR COVERING
DRAINAGE AREA
REFER NOTE 6
FLASHING BY BUILDER
SILL TILE
R
E
V
E
A
L
3
9
1
7
I nstallation Details Aluminium Entry Frames
(including Louvre Windows)
Brick Veneer Double Brick Weatherboard
Notes:
1. Units have been factory assembled in a steel jigto ensure that correct operating
tolerances exist at the time of despatch.
2. Incorrect re-alignment on site will effect proper operation and may lead to weather
penetration.
3. Ensure that there is no external obstructions to interfere with the operation of the
hinged panels.
4. Duringinstallation ensure unit is plumb and level in all planes in addition to a final
check of diagonals to ensure squareness.
5. Flashingof the outer frame is recommended and should be carried out by a
qualified builder.The flashinginstallation should comply with the relevant building
codes and standards.
6. If sill is placed on a flat slab or flooringand the sill fin is snapped off,then flashingis
highly recommended to prevent water ingress.
7. Doors and frames are non structural and cannot support any overlyingmass.
8. The details shown are recommendations only.The builder is responsible for correct
installation which should comply with the relevant buildingcodes and standards.
9. For weatherboard installation (refer jamb plan view):
a) prepare double stud opening,
b) insert frame into openingand fix through fin,
c) slide weatherboard and gyprock in behind frame.
JAMB PLAN VIEW
FLASHING
BY BUILDER
RENDER
HEAD ELEVATION
SILL ELEVATION
SILL ELEVATION
300PaSUBSILL ELEVATION
JAMB PLAN VIEW
HEAD ELEVATION
JAMB PLAN VIEW
HEAD ELEVATION
4
9
.
3
WEATHERBOARD
INSTALLATION:
1.UNITSHAVE BEEN FACTORY ASSEMBLED IN A STEEL JIG TO ENSURE THAT CORRECT OPERATING
TOLERANCESEXIST AT THE TIME OF DESPATCH.
2.INCORRECT RE-ALIGNMENT ON SITE WILL EFFECT PROPER OPERATION AND MAY LEAD TO
WEATHER PENETRATION.
3.DURING INSTALLATION ENSURE UNIT ISPLUMB AND LEVEL IN ALL PLANESIN ADDITION TO
A FINAL CHECK OF DIAGONALSTO ENSURE SQUARENESS.
4.FLASHING OF THE OUTER FRAME ISRECOMMENDED AND SHOULD BE CARRIED OUT BY A
QUALIFIED BUILDER.THE FLASHING INSTALLATION SHOULD COMPLY WITH THE RELEVANT
BUILDING CODESAND STANDARDS.
5.DOORSAND FRAMESARE NON STRUCTURAL AND CANNOT SUPPORT ANY OVERLYING MASS.
6.OPTIONAL HARDWOOD SILL TO BE ISOLATED FROM SLAB WITH FLASHING TO PREVENT
MOISTURE ABSORBTION AND POSSIBLE WARPING.IF USED ON WIDE OPENINGSSUCH AS4 PANEL
DOORS,THEN IT ISRECOMMENDED FOR BUILDER TO FIX HARDWOOD SILL TO SLAB AT MAX
600CRS.
7.THE DETAILSSHOWN ARE RECOMMENDATIONSONLY.THE BUILDER ISRESPONSIBLE FOR
CORRECT INSTALLATION WHICH SHOULD COMPLY WITH THE RELEVANT BUILDING CODESAND
STANDARDS.
NOTES
INNER BRICKWORK
LINTELS
DOUBLEBRICK LUG
AG-10.814MINIMUM
OF4PER JAMBAT
MAX 600CRS.
OUTER BRICKWORK
INNER BRICKWORK OUTER BRICKWORK
(FLAT SLAB)
FLOOR COVERING
FLASHING
BY BUILDER
SILL TILE
(FLAT SLAB)
FLOOR COVERING
OPTIONAL FLASHING
BY WIDELINEFACTORY
FITTED TO SILL
(REBATED SLAB)
FLOOR COVERING
SILL TILE
STUD
R
E
V
E
A
L
NAIL REVEAL TO
HEAD TRIMMER
AT MAX 600CRS.
ARCHITRAVE
BY BUILDER
REVEAL
OUTER BRICKWORK
LINTEL
REVEAL
ANGLE
BY BUILDER
OUTER BRICKWORK
SILL TILE
GYPROCK
NAIL THROUGH REVEAL
PACKER BY BUILDER
SHOULD BEAPPROX.
10mmTHICK.
ARCHITRAVEBY BUILDER
NAIL REVEAL TO
HEAD TRIMMER
AT MAX 600CRS.
ARCHITRAVE
BY BUILDER
90mmSTUD
WEATHERBOARD
R
E
V
E
A
L
REVEAL
G
Y
P
R
O
C
K
W
E
A
T
H
E
R
B
O
A
R
D
ANGLE
BY BUILDER
PACKER BY BUILDER
SHOULD BEAPPROX.
10mmTHICK.
ARCHITRAVEBY BUILDER
NAIL THROUGH REVEAL
DRAIN
ALUMINIUM ANGLECAULKED &
SCREWED TO FLOOR BY BUILDER
4
0
OPTIONAL HARDWOOD SILL
(REFER NOTE6)
53.5
6
8
.
3
3
3
.
5
100
81
7
9
.
3
FLASHING BY BUILDER
10mm
CLEARANCE
GYPROCK
1
1
2
10mm
CLEARANCE
FLASHING
BY BUILDER
GYPROCK
HEAD TRIMMER
I nstallation Details Doors
Sliding Doors
Brick Veneer Double Brick Weatherboard
Notes:
1. Incorrect re-alignment on site will effect proper operation and may lead to weather
penetration.
2. Duringinstallation ensure unit is plumb and level in all planes in addition to a final
check of diagonals to ensure squareness.
3. Flashingof the outer frame is recommended and should be carried out by a
qualified builder.The flashinginstallation should comply with the relevant building
codes and standards.
4. Doors and frames are non structural and cannot support any overlyingmass.
5. Optional hardwood sill to be isolated from slab with flashingto prevent moisture
absorbtion and possible warping.If used on wide openings such as 4 panel doors,
then it is recommended for builder to fix hardwood sill to slab at max 600crs.
6. The details shown are recommendations only.The builder is responsible for correct
installation which should comply with the relevant buildingcodes and standards.
Various Sill
Installations
15
Widelines policy of continued improvement may result in a change of specification without notice.
16
Widelines policy of continued improvement may result in a change of specification without notice.
REVEAL
R
E
V
E
A
L
FLASHING BY
BUILDER
PACKERSBY
BUILDER
LINTEL
NAIL REVEAL TO
HEAD TRIMMER AT
MAXIMUM 600CRS.
USEPACKING
IFREQUIRED
ARCHITRAVE
BY BUILDER
FIX HEAD VERTICALLY THROUGH
CENTRELINEOF
HANGER WHEEL SET
HANGER WHEEL SET
HANGER WHEEL SET
TRACK.RECOMMENDED
AT 600CRSMAX, USEPACKERSIF
REQUIRED.REFER NOTE8.
ANGLEBY
BUILDER
OUTER
BRICKWORK HEAD TRIMMER
REVEAL
HEAD ELEVATION
FIXING THROUGH JAMB
ISRECOMMENDED.
OUTER BRICKWORK
GYPROCK
JAMB PLAN VIEW
SECONDARY FIXING CAN
BEDONETHROUGH
REVEAL INTO STUD
PACKER IFREQUIRED BY
BUILDER SHOULD BE
APPROX.10mmTHICK.
ARCHITRAVEBY BUILDER
STUD
STUD
R
E
V
E
A
L
JAMB PLAN VIEW
HEAD ELEVATION
DOUBLEBRICK LUG
AG-10.814MINIMUM
OF4PER JAMBAT
MAX 600CRS.
INNER BRICKWORK
OUTER BRICKWORK
JAMB PLAN VIEW
HEAD ELEVATION
GYPROCK
ARCHTRAVEBY BUILDER
PACKER IFREQUIRED BY
BUILDER SHOULD BE
APPROX.10mmTHICK.
HEAD SUPPOR
ARCHITRAVE
BY BUILDER
NAIL REVEAL TO
HEAD TRIMMER AT
MAXIMUM 600CRS.
USEPACKING
IFREQUIRED
TS
BY BUILDER
WEATHERBOARD
ARCHITRAVEOR
COVERPLATEBY
BUILDER TO SUIT.
SEAL OR FLASH
TO PREVENT WATER
INGRESSABOVE
BI-FOLD HEAD.
FIX HEAD VERTICALLY THROUGH
CENTRELINEOFTRACK.RECOMMENDED
AT 600CRSMAX, USEPACKERSIF
REQUIRED.REFER NOTE8.
RENDER
FLASHING BY
PACKERSBY
BUILDER
BUILDER
ANGLEBY
BUILDER
FIX HEAD VERTICALLY THROUGH
CENTRELINEOFTRACK.RECOMMENDED
AT 600CRSMAX, USEPACKERSIF
REQUIRED.REFER NOTE8.
BRICKWORK
OUTER
BRICKWORK
INNER
I nstallation Details Doors
Bi-fold Doors
Brick Veneer Double Brick Weatherboard
Notes:
1. Incorrect re-alignment on site will effect proper operation and may lead to weather penetration.
2. Ensure that there is no external obstructions to interfere with the operation of the foldingpanels.
3. Duringinstallation ensure unit is plumb and level in all planes in addition to a final check of
diagonals to ensure squareness.Special attention should be given to the head and sill of the frame
with use of stringline.The mass of doors hangingfromthe head track is approximately 35kgper
horizontal lineal metre for a 2100mmhigh frame.
4. Flashingof the outer frame is recommended and should be carried out by a qualified builder.
The flashinginstallation should comply with the relevant buildingcodes and standards.
5. If sill is placed on a flat slab or flooringand the sill fin is snapped off,then flashingis highly
recommended to prevent water ingress.
6. Ensure fixingdoes not interfere with operation of wheel carriage.Remove all swarf fromtrack
after fixingas it may imbed into wheels causingrough operation and void warranty.
7. The details shown are recommendations only.The builder is responsible for correct installation
which should comply with the relevant buildingcodes and standards.
Care: Keep track and channel dry and clear fromdirt and debris.Spray tracks with a light lubricant regularly.
Doors and hardware should be washed regularly to prevent salt and contaminant build-up.
SILL ELEVATION
FLASHING BY BUILDER
REFER NOTE 6
DRAINAGE AREA
3
9
3
2
SILL TILE
Panel Fitting Instructions
Bifold Doors & Windows
I nstallation Details Doors
Bi-fold Doors
Wideline is proud to announce that it is a foundingmember of the Australian WindowAssociation (AWA).
National Number:
1300 WIDELINE
Central Coast
Registered H ead O f ce
174 Paci c H ighw ay
TU G G ERA H
PO Box 378
W yong N SW 2259
Phone: 1300 943 354
Facsim ile: 02 4350 8429
Em ail: sales@ w ideline.com .au
Sydney
89 Victoria Road
PA RRA M ATTA
PO Box 6473
Parram atta Business C entre
N SW 2150
Phone: 1300 943 354
Facsim ile: 02 8835 4400
Em ail: sales@ w ideline.com .au
Newcastle
154 H annell Street
W IC KH A M N SW 2293
Phone: 1300 943 354
Facsim ile: 02 4978 8550
Em ail: sales@ w ideline.com .au
Yatala
Building 20, 63 Burnside Road
YATA LA Q LD 4207
PO Box 17,
Beenleigh Q LD 4207
Phone: 07 3441 9700
Facsim ile: 07 3441 9797
Em ail: sales@ w ideline.com .au
www.wideline.com.au
Please be sure to visit our comprehensive website; it features a window
planning section to help you choose the right window for your home, as well
as a comprehensive virtual showroom of our complete product range.
Contacts
2008 W ideline Pty Ltd. A BN 11 000 945 068
A ll products show n in this catalogue are representative of w hat can be achieved and are subject to individual
nishes and installation techniques. W ideline Pty Ltd reserves the right to m odify sizes and details w ithout notice.
W ideline Pty Ltd does not accept liability for the appearance of your nished product.
TEC H A LU M 09/08
This association has been established to ensure that m anufacturers produce w indow s and
doors that m eet if not exceed stringent safety and structural standards. From m aterial
selection and w orkm anship quality to w eather sealing and applied nishes, all aspects of
production are scrutinised to ensure that they m eet the relevant A ustralian standards.
The AW A label on each and every W ideline product m eans that you can be con dent
that our vast range has been tested, certi ed and guaranteed by independent inspectors
accredited by the N ational A ssociation of Testing A uthorities.
AWA Australian Window Association