Sie sind auf Seite 1von 10

DC type: Approx. 0.9W to 1.

1W;
AC type: Approx. 1.2VA to 1.8VA
Features
File No.:E133481
File No.:R50147087
Contact resistance
Contact rating
(Res. load)
Dielectric
strength
Shock resistance
HONGFA RELAY
Coil power
File No.:CQC09002030026 (DC type)
CQC09002030027 (AC type)
1 x 10
5
OPS
(See approval reports for more details)
SO9001, SO/TS16949 , SO14001, OHSAS18001, ECQ QC 080000 CERTFED 2013 Rev. 1.00
35
Notes: Only some typical ratings are listed above. f more details are
required, please contact us.
7A 250VAC/30VDC
7A 250VAC/30VDC
TV
5A 250VAC/30VDC
5A 250VAC/30VDC
Contact arrangement
Contact material
Max. switching voltage
Max. switching current
Max. switching power
HF18FF
2C, 3C 4C
100m max.(at 1A 6VDC)
See ordering info.
nsulation resistance
Between coil & contacts
Between open contacts
Between contact sets
Operate time (at nomi. volt.)
Release time (at nomi. volt.)
Temperature rise (no-load, at nomi.volt.)
Functional
Destructive
Vibration resistance
Humidity
Ambient temperature
Termination
Unit weight
Construction
1000M (at 500VAC)
1500VAC 1min
1000VAC 1min
1500VAC 1min
DC type: 25ms max.
DC type: 25ms max.
60K max.
98m/s
2
980m/s
2
10Hz to 55Hz 1mm DA
5% to 85% RH
-40 to 70
PCB, Plug-in
Approx. 37g
Dust protected
MINIATURE INTERMEDIATE POWER RELAY
CONTACT DATA
CHARACTERISTICS
COIL
Nominal
Voltage
VDC
Coil
Resistance
Pick-up
Voltage
VDC
max.
Drop-out
Voltage
VDC
min.
COIL DATA
5
6
12
24
48
110
27.5 x (1 10%)
40 x (1 10%)
160 x (1 10%)
650 x (1 10%)
2600 x (1 15%)
11000 x (1 15%)
4.0
4.8
9.6
19.2
38.4
88.0
0.50
0.60
1.20
2.40
4.80
11.0
6
12
24
48
120
220/240
11.5 x (1 10%)
46 x (1 10%)
184 x (1 10%)
735 x (1 10%)
4550 x (1 15%)
14400 x (1 15%)
4.80
9.60
19.2
38.4
96.0
176.0
1.80
3.60
7.20
14.4
36.0
72.0
Nominal
Voltage
VAC
Coil
Resistance
Pick-up
Voltage
VAC
max.
Drop-out
Voltage
VAC
min.
Mechanical endurance
Electrical endurance
& 7A switching capability (2C, 3C type)
& 1.5kV dielectric strength
(between coil and contacts)
& Gold plated contact available
& Conform to the CE low voltage directive
& Sockets available
& 2 to 4 pole configurations
& Environmental friendly product (RoHS compliant)
& Outline Dimensions: (28.0 x 21.5 x 35.0) mm
SAFETY APPROVAL RATINGS
7A 250VAC/30VDC 5A 250VAC/30VDC
250VAC / 30VDC
7A 5A
210W 150W
1750VA 1250VA
2 x 10
7
OPS
at 23
Max.
Allowable
Voltage
VDC
Max.
Allowable
Voltage
VAC
5.5
6.6
13.2
26.4
52.8
121
6.6
13.2
26.4
52.8
132
264
UL/CUL
2 Form C
4 Form C
3 Form C
2 Form C
4 Form C
3 Form C
Notes: 1) The data shown above are initial values.
2) UL insulation system: Class A
1: Socket 2: PCB 5: Flange-Mounting
Customer speciaI code
There pins aren't
available for 2 Form C
36
HF18FF/ ____-2Z2 ___/ 3Z2___
HF18FF/ ____-4Z2 ___ HF18FF/ ____-4Z1 ___
HF18FF/ ____-2Z1 ___/ 3Z1___
( See the following )
0.5
0.5
2.5
35max 5.8

1.2x2.2 8-
6
.
8
2
8
m
a
x
3
6
9
14
21.5max
2
5
8
1
4
7
13
3.5
0.5
35max
1
0.5
6
.
8
2
8
m
a
x
21.5max
2
5
1
4
8 7
13
3
6
9
14
There pins aren't
available for 2 Form C
35max
0.5
0.5
14 -
5.8
1.2x2.2
2.5
21.5max
10 9
!3
2
6
1
5
2
8
m
a
x
6
.
8
12
!1
11
4
8
3
7
3.5
0.5
35max
0.5
1
8
4
12
14
11 9
13
10
3
7
2 1
6 5
2
8
m
a
x
6
.
8
21.5max
CoiI voItage form A: AC NiI: DC
HF18FF / A 1 D 012 -2Z
Mounting Termination
LED D: With LED NiI: Without LED
CoiI voItage DC: 5VDC to 110VDC AC: 6VAC to 240VAC
ORDERING INFORMATION
Type
Contact arrangement 2Z: 2 Form C 3Z: 3 Form C 4Z: 4 Form C
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Outline Dimensions
G
Contact materiaI
(XXX)
Unit: mm
T: AgSnO2 G: AgCe + Au plated
NiI: AgCe TG: AgSnO2 + Au plated
Notes: 1) We also can supply the special type with terminals numbered 1,4,5,8,9,12,13,14 for 2 poles.
+0. 4
- 0. 2
+0. 4
- 0. 2
37
HF18FF/ ____-4Z5 ___
Wiring Diagram
PCB Layout
Remark: 1) n case of no tolerance shown in outline dimension: outline dimension 1mm, tolerance should be 0.2mm; outline dimension `1mm
and 5mm, tolerance should be 0.3mm; outline dimension `5mm, tolerance should be 0.4mm.
2) The tolerance without indicating for PCB layout is always 0.1mm.
(Bottom view)
(Bottom view)
2 Form C 3 Form C 4 Form C
2 Form C 3 Form C 4 Form C
35max
0.5
2
0.5
5.8
3
8
2-3.5
6
.
8
3
8
2
8
m
a
x
4
4
m
a
x
21.5
3.5
10
13
9
14
11 12
6
2 1
5
3 4
7 8
2 Form C(With LED) 3 Form C(With LED) (With LED)
2 Form C
(DC, With fly-wheel diode)
3 Form C
(DC, With fly-wheel diode)
4 Form C
(DC, With fly-wheel diode)
4 Form C
Remark: For AC parts with diode, the positive and negative pole markings on wiring diagram are not applicable.
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT
Unit: mm
Outline Dimensions Mounting Holes
6
.
8
13.2
1
6
.
8
1
2
.
7
13.2
13.2
4.4
6
.
4
14-1.3 11-1.3 8-1.3
13
7
4
1
14
9
6
3
13 14
7
4
8
5
1 2
9
6
3
9
5
10
6
1 2
11
7
12
8
3 4
13 14
13
7
4
1
14
9
6
3
13 14
7
4
8
5
1 2
9
6
3
9
5
10
6
1 2
11
7
12
8
3 4
13 14
_
+
_
+
_
+
13
7
4
1
14
9
6
3
13 14
7
4
8
5
1 2
9
6
3
9
5
10
6
1 2
11
7
12
8
3 4
13 14
_
+
_
+
_
+
+0. 4
- 0. 2
CHARACTERISTIC CURVES
5 10 50 100 500
DC Resistive Load
DC nductive Load
0.1
0.5
1
10
5
AC nductive
load
AC Resistive load
C
o
n
t
a
c
t
C
u
r
r
e
n
t
(
A
)
Contact Voltage (V)
MAXMUM SWTCHNG POWER
(2, 3 Form C)
MAXMUM SWTCHNG POWER
(4 Form C)
5 10 50 100 500
DC Resistive Load
DC nductive Load
0.1
0.5
1
10
5
AC nductive
load
AC Resistive load
C
o
n
t
a
c
t
C
u
r
r
e
n
t
(
A
)
Contact Voltage (V)
200 200
File No.: E253370
Features

0.8Nm

7mm
Dielectric Strength
min.
ReIay Sockets
& The dielectric strength can reach 2000VAC
and the insulation resistance is 1000M
& Three mounting types are available: PCB mounting
screw mounting and DN rail mounting.
& With finger protection device
& Many kinds of plug-in modules are available
with the function of energizing indication and
wiring protection.
& Components available: retainer, marker and plug-in
module
& Environmental friendly product (RoHS compliant)
18FF-2Z-A2
18FF-2Z-C1
18FF-2Z-C2
18FF-2Z-C4
18FF-2Z-C5
18FF-2Z-C6
18FF-2Z-C7
18FF-2Z-C8
18FF-3Z-C1
18FF-3Z-C4
18FF-3Z-C5
18FF-4Z-A2
18FF-4Z-C1
18FF-4Z-C2
18FF-4Z-C4
18FF-4Z-C5
18FF-4Z-C6
18FF-4Z-C7
18FF-4Z-C8
2000VAC
2000VAC
2000VAC
2000VAC
2000VAC
2000VAC
2000VAC
2000VAC
2000VAC
2000VAC
2000VAC
2000VAC
2000VAC
2000VAC
2000VAC
2000VAC
2000VAC
2000VAC
2000VAC
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
250VAC
7A
7A
7A
7A
7A
7A
7A
7A
7A
7A
7A
7A
7A
7A
7A
7A
7A
7A
7A
-40 to 70
-40 to 70
-40 to 70
-40 to 70
-40 to 70
-40 to 70
-40 to 70
-40 to 70
-40 to 70
-40 to 70
-40 to 70
-40 to 70
-40 to 70
-40 to 70
-40 to 70
-40 to 70
-40 to 70
-40 to 70
-40 to 70
0.8Nm
0.6Nm
0.6Nm
0.6Nm
0.6Nm
0.6Nm
0.8Nm
0.6Nm
0.6Nm

0.8Nm
0.8Nm
0.6Nm
0.6Nm
0.6Nm
0.6Nm
0.6Nm
7mm
7mm
7mm
7mm
7mm
7mm
7mm
7mm
7mm

7mm
7mm
7mm
7mm
7mm
7mm
7mm
Type
Screw Torque Wire Strip Length
CHARACTERISTICS
Nominal
Voltage
Ambient Temperature
Nominal
Current
38
Screw Terminal,
DN rail or Screw mounting,
Applicable for 2 poles
Screw Terminal,
DN rail or Screw mounting,
With finger protection device
Applicable for 2 poles
Screw Terminal,
DN rail or Screw mounting,
With finger protection device
Applicable for 2 poles
PCB Terminal,
PCB mounting
Applicable for 2 poles
Screw Terminal,
DN rail or Screw mounting,
With finger protection device
Applicable for 2 poles
5
9
15
2-4.5
5
9
15
2-4.5
8 5
9 12
13 14
4 1
8 5
9 12
13 14
4 1
3
5
.
4
7
2
30
16.5
4
23
2-4.2x5
6
3.4
6
2
4
.
8
4
2.8
15.8
0
.
3
1
4
.
1
6
.
3
2
8
.
8
6
.
4
13.2
21.5
6
.
4
6
.
4
6
.
4
6
.
3
4
.
1
13.2
8- 1.3
Socket PCB Layout Wiring Diagram Outline Dimensions
Components
Available
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT Unit: mm
18FF-2Z-A2
18FF-2Z-C1
18FF-2Z-C2
18FF-2Z-C4
18FF-2Z-C5
metallic retainer
18FF-H1
plastic retainer
18FF-H4
metallic retainer
18FF-H5
marker
18FF-M1
plug-in module
HFAA to HFHU*
plastic retainer
18FF-H4
metallic retainer
18FF-H5
marker
18FF-M1
plug-in module
HFAA to HFHU*
(Top View)
(Top View)
(Top View)
metallic retainer
18FF-H2
be used in sets)
metallic retainer
18FF-H2
be used in sets)
(Top View)
(Top View)
(Top View)
39
30
16.5
14 13
23
3
5
.
4
3.4
9 12
8 5
1 4
2-4.2x5 6 6
(Top View)
7
1
.
2
(Top View)
42.6
24
3
5
.
4
7
5
.
2
27.2
22
2- 3
(Top View)
27.2
29.1
3
5
.
4
24
60.8
42.6
7
5
41
12
11
9
14
5
44
8
42
4
12
1
A2
14
A1
13
A2
14
22
2- 3
COM
NO
NC
COL
41
12
11
9
14
5
44
8
42
4
12
1
A2
14
A1
13
COM
NO
NC
COL
Screw Terminal,
DN rail or Screw mounting,
Applicable for 2 poles
22
5
9
2-4.5
9
11 10
8 7
6 5 4
1 2 3
3
5
.
4
30
16.5
11 10
29.5
4
7 8 9
7
2
2-4.2X5
6
3.4
6
1 2 3
4 5 6
Screw Terminal,
DN rail or Screw mounting,
With finger protection device
Applicable for 2 poles
Screw Terminal,
DN rail or Screw mounting,
With finger protection device
Applicable for 2 poles
Screw Terminal,
DN rail or Screw mounting,
Without finger protection d
evice
Applicable for 3 poles
metallic retainer
18FF-H5
marker
18FF-M2
plastic retainer
18FF-H4
marker
18FF-M3
metallic retainer
18FF-H2
be used in sets)
metallic retainer
18FF-H6
be used in sets)
marker
18FF-M2
Socket PCB Layout Wiring Diagram Outline Dimensions
Components
Available
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT Unit: mm
(Top View)
(Top View)
(Top View)
18FF-2Z-C6
18FF-2Z-C7
18FF-2Z-C8
18FF-3Z-C1
(Top View)
(Top View)
(Top View)
(Top View)
(Top View)
(Top View)
40
3
5
.
4
29
6
3
19
25
30.3
1 4
5
12 9
8
14 13
25
2- 4
29
19
3
5
.
4
30.3
6
3
41
12
11
9
14
5
44
8
42
4
12
1
A2
14
A1
13
25
2- 4
29
19
3
5
.
4
30.3
6
6
.
7
41
12
11
9
14
5
44
8
42
4
12
1
A2
14
A1
13
24.2
2- 3
COM
NO
NC
COL
COM
NO
NC
COL
Screw Terminal,
DN rail or Screw mounting,
Witht finger protection device
Applicable for 3 poles
Screw Terminal,
DN rail or Screw mounting,
With finger protection device
Applicable for 3 poles
22
5
9
2-4.5
6
.
4
13.2
14-1.3
6
.
4
4.4
6
.
3
4
.
1
14 4 13
12 11 9 10
5 6 8 7
3 2 1
30
16.5
3
5
.
4
3.4
6
29.5
4 14 13
4
7
2
9 10 11 12
8 7 6 5
2-4.2X5
6
1 2 3
14-M3 x 8
PCB Terminal,
PCB mounting
Applicable for 4 poles
Screw Terminal,
DN rail or Screw mounting,
Withtout finger protection
device
Applicable for 4 poles
metallic retainer
18FF-H1
plastic retainer
18FF-H4
metallic retainer
18FF-H5
marker
18FF-M1
plug-in module
HFAA to HFHU*
plastic retainer
18FF-H4
metallic retainer
18FF-H5
marker
18FF-M1
plug-in module
HFAA to HFHU*
Socket PCB Layout Wiring Diagram Outline Dimensions
Components
Available
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT Unit: mm
18FF-3Z-C4
18FF-3Z-C5
18FF-4Z-A2
18FF-4Z-C1
(Top View)
(Top View)
(Top View)
(Top View)
(Top View)
metallic retainer
18FF-H2
be used in sets)
(Top View)
41
(Top View)
3
5
.
4
24
42.6
7
5
.
2
27.2
31
9
21
8
11
7
14
4
24
5
34
6
32
3
22
2
12
1
A2
14
A1
13
22
2- 3
(Top View)
3
5
.
4
60.8
7
5
29.1
42.6
24
27.2
41
12
21
10
11
9
14
5
24
6
44
8
42
4
22
2
12
1
A2
14
A1
13
A2
14
COM
NO
NC
COL
COM
NO
NC
COL
22
2- 3
2
4
.
8
4
2.8
16
1
0
.
3
2
8
.
8
4.4
13.2
6
.
4
21.5
6
.
3
4
.
1
6
.
4
22
5
9
2-4.5
3
5
.
4
7
2
4
30
31
16.5
14 13 4
29.5
9 10 11 12
2-4.2x5
6
3.4
6
5 6 7
3 1 2
8
14-M3x8
14 4 13
12 11 9 10
5 6 8 7
3 2 1
Screw Terminal,
DN rail or Screw mounting,
With finger protection device
Applicable for 4 poles
Screw Terminal,
DN rail or Screw mounting,
With finger protection device
Applicable for 4 poles
Screw Terminal,
DN rail or Screw mounting,
With finger protection device
Applicable for 4 poles
Screw Terminal,
DN rail or Screw mounting,
Applicable for 4 poles
(Top View)
(Top View)
metallic retainer
18FF-H2
be used in sets)
(Top View)
(Top View)
(Top View)
(Top View)
Socket PCB Layout Wiring Diagram Outline Dimensions
Components
Available
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT Unit: mm
18FF-4Z-C6
18FF-4Z-C2
18FF-4Z-C4
18FF-4Z-C5
(Top View)
(Top View)
plastic retainer
18FF-H4
metallic retainer
18FF-H5
marker
18FF-M1
plug-in module
HFAA to HFHU*
plastic retainer
18FF-H4
metallic retainer
18FF-H5
marker
18FF-M1
plug-in module
HFAA to HFHU*
metallic retainer
18FF-H6
be used in sets)
marker
18FF-M2
42
27.2
3
5
.
4
24
42.6
7
5
.
2
41
12
31
11
21
10
11
9
14
5
24
6
34
7
44
8
42
4
32
3
22
2
12
1
A2
14
A1
13
22
2- 3
60.8
3
5
.
4
7
5
29.1
42.6
24
27.2
41
12
31
11
21
10
11
9
14
5
24
6
34
7
44
8
42
4
32
3
22
2
12
1
A2
14
A1
13
A2
14
22
2- 3
3
5
.
4
29
6
3
19 25
30.3
3 2 1 4
7 6 5
12 11 10 9
8
14 13
25
2- 4
COM
NO
NC
COL
COM
NO
NC
COL
Note: 18FF-H2 retainer has to be used in sets, please
pay special attention while placing the order.
Screw Terminal,
DN rail or Screw mounting,
With finger protection device
Applicable for 4 poles
Screw Terminal,
DN rail or Screw mounting,
With finger protection device
Applicable for 4 poles
(Top View)
(Top View)
Socket PCB Layout Wiring Diagram Outline Dimensions
Components
Available
OUTLINE DIMENSIONS, WIRING DIAGRAM AND PC BOARD LAYOUT Unit: mm
Unit: mm DIMENSION OF RELATED COMPOENT (AVAILABLE)
18FF-4Z-C7
18FF-4Z-C8
(Top View)
(Top View)
metallic retainer
18FF-H5
marker
18FF-M2
plastic retainer
18FF-H4
marker
18FF-M3
43
18FF-H1 (metallic retainer)
Retainer
18FF-H2 (metallic retainer)
30.3
3
5
.
4
29
6
3
19
41
12
31
11
21
10
11
9
14
5
24
6
34
7
44
8
42
4
32
3
22
2
12
1
A2
14
A1
13
25
2- 4
30.3
19
3
5
.
4
4
5
.
2
29
6
6
.
7
41
12
31
11
21
10
11
9
14
5
24
6
34
7
44
8
42
4
32
3
22
2
12
1
A2
14
A1
13
24.2
2- 3
COM
NO
NC
COL
COM
NO
NC
COL
3
2
4
30.8
2-R2
8
2-R2.3
0.3
0
4.5
4
4
.
5
0
.
2
8*
3
5
.
6
1.2
+0.1
+
0
.
1
-
0
.
3
-
Notes: * Please refer to the product datasheet if plug-in module is required.
Disclaimer
This datasheet is for the customers' reference. All the specifications are subject to change without notice.
We could not evaluate all the performance and all the parameters for every possible application. Thus the user should be in a right position to
choose the suitable product for their own application. f there is any query, please contact Hongfa for the technical service. However, it is the user's
responsibility to determine which product should be used only.
Xiamen Hongfa Electroacoustic Co., Ltd. All rights of Hongfa are reserved.
Note: 18FF-H6 retainer has to be used in sets, please
pay special attention while placing the order.
Unit: mm DIMENSION OF RELATED COMPOENT (AVAILABLE)
44
18FF-H4 (plastic retainer) 18FF-H5 (metallic retainer) 18FF-H6 (metallic retainer)
Things to be noticed when seIecting sockets:
1. Please choose suitable relay socket according to the actual mounting environment, relay contact poles and terminal layout. f there is any query
on selection, please contact Hongfa for the technical service.
2. Socket which can be mounted with markers is furnished with a marker; as for other related components, they should be selected separately.
Please do give clear indication of the types of relay sockets and related components you choose while placing order.
3. The above is only an example of typical socket and related component type which is suitable to HF18FF relay. f you have any special requirements,
please contact us.
Marker
Retainer
6.8
5
13.1
4
7
12.2
18FF-M1 18FF-M2
26.2
9.2
8
.
6
2.7
3.6
14.4
1
0
.
1
18FF-M3
15.6
9
1.5
6.5
3
5
.
9
-
0
.
2
0
26.5 22.8
6
0
13.4
23.7
3
5
.
3
0
-
0
.
3

Das könnte Ihnen auch gefallen