Compact Efficiency for Flexibility in Analytical & Preparative Projects Overview: The BLC-20 Series Analytical HPLC systems use a high-quality, precision monochromator based spectrophotometer for a full range of wavelengths from 190-800nm for selective analyses integrated into a complete LC package. The 20-series is easily upgraded to a gradient System with the Buck-Chrom controller & Peak-Simple data transfer, optional semi-prep systems for material isolation with optional Auto- Sampler, Fraction Collector, RI Detector, & Fluorescence detector.. BLC-20 BLC-20G Features: Completely integrated design provides full functionality in a small foot print suitable for many types of analysis. Electronic controls for pump and detectors allow fully automated operation for reproducible methods with Buck-Chrom gradient controller. Output to renowned Peak-Simple data station for QC testing and R&D flexibility; or an analog recorder. Fully configured packages include reverse-phase C-18 column, solvent delivery system, syringe and detector. Variable wavelength systems give hi-resolution selectivity [5nm] from 190- 360nm (D2) and 360-800nm (Tungsten). Wide selection of reverse-phase (C-18, C-8, Amino, Cyano, Phenyl), normal (SiO2 & Al203) and GPC columns available. Completely bio-compatible contact surfaces in All-Polymer design (PEEK, Teflon, Ruby, Sapphire, Quartz) eliminates Ionic contamination, with stainless steel option for high-pressure and GPC/SEC work. Precision electronic Pump Control from 0.01-9.99ml/min (Analytical) and 0.10-40.0ml/min (Semi-Preparative) Detector flowcells quickly changed from Analytical (7mm pathlength / 10 L) to Preparative (2mm pathlength / 4L). Suitable for any HPLC application from cosmetics, foods, pharmaceuticals and education; to paints, & pigments, polymers, petrochemicals and botanicals. The basic BLC-10 series HPLC systems have a very sensitive and stable filter photometer for routine assays at the most common wavelengths. The BLC-10 comes equipped with a 254nm fixed wavelength filter photometer. The BLC-10 can also accomodate a filter for the following wavelengths; 280, 365, 420, 505 & 540nm. The BLC-10 comes complete with a column, fittings, a pump and injector hardware for instant setup and analyses. BLC-10 For more information call 800-562-5566 or Click www.bucksci.com Software All Chromatography instruments from Buck are easily and fully controlled by the PeakSimple Software package; directly or through a DataStation. Control of data collection, external switches, detector response range and auto-zero, and pump flow can all be set in the program for instant reloading; thus simplifying method development. Complete access to the data files, calibration parameters and report format provides full documentation of test protocols. Variable integration windows, multi-point polynomial calibration and up to 4-channel inputs make the PeakSimple package more powerful than systems costing 10X as much! BLC-20 Variable Wavelength HPLC: PUMP Flow Rate 0.01-9.99ml/min (Ana) 0.10-40ml/min (PREP) Pressure 0-3000PSI max (PEEK) 0-5000PSI max (SS) Accuracy 1% MAX deviation Presicion <0.5% RSD Panel Controls Run/Stop & Prime Flow Control & Pump Status Display Flow rate [ml/min] DETECTOR = Wavelength Range 190-360nm. UV [D2 Lamp] 360-800nm. VIS [W Lamp] Bandpass [Res] 5nm. Flowcell 10uL Volume, 7mm. Path (ANA) 4uL Volume, 2mm. Path (PREP) ABS Range 0.005 to 1.0 ABS [2ABS MAX] Drift <2 x 10-4 A/hour @ 254nm. Noise <2 x 10-5 A @ 254nm. Linearity >2% Panel Controls ABS Range, Auto-Zero, WL Wavelength Accuracy Better than 2nm. Reproducibility Better than 1nm. Recorder Output 10mV full-scale Integrator Output 1V/ABS to 2V (=2.0ABS) Display ABS: 4.5 digits to 1.999ABS Wavelength: 3 digits Shipping Weight 40 lbs. Dimensions 16W x 7H x 17D BLC-20G GRADIENT HPLC: PUMP Flow Rate 0.01-9.99ml/min (Ana) 0.10-40ml/min (PREP) Pressure 0-3000PSI max (PEEK) 0-5000PSI max (SS) Accuracy 1% MAX deviation Presicion <0.5% RSD BUCK-CHROM CONTROLLER Gradient Range 0-100% Increments 0.5% Gradient Accuracy 1% MAX deviation Precision < 1% variation from 10%-90% Flow Accuracy (2-pump) 1% MAX deviation Precision (2-pump) <0.5% RSD Software Controls Wavelength, Min/Max Pressure Limits, Sample ID, Solvent and ColumnSpecs, Flow, Gradient Ramps, Signal Processing for 2 Detectors, Relay Controls for Fraction Collector & Auto- sampler Software Displays Real-Time Detector signal(s) and Pressure readings, chromatograms, gradient & Pressure Curves (graphical) Phone: 203-853-9444 FAX: 203-853-0569 ~ E-Mail: sales@bucksci.com Homepage: www.bucksci.com BLC-20 display shows full range of controls BLC-10 components are fully integrated Hardware Specifications