Model BLC-20 Isocratic & BLC-20G Gradient HPLC


Compact Efficiency for Flexibility in Analytical & Preparative Projects
Overview:
The BLC-20 Series Analytical
HPLC systems use a high-quality,
precision monochromator based
spectrophotometer for a full
range of wavelengths from
190-800nm for selective analyses
integrated into a complete LC
package.
The 20-series is easily upgraded
to a gradient System with the
Buck-Chrom controller &
Peak-Simple data transfer, optional
semi-prep systems for material
isolation with optional Auto-
Sampler, Fraction Collector, RI
Detector, & Fluorescence detector..
BLC-20 BLC-20G
Features:
Completely integrated design provides full functionality in a small foot
print suitable for many types of analysis.
Electronic controls for pump and detectors allow fully automated
operation for reproducible methods with Buck-Chrom gradient controller.
Output to renowned Peak-Simple data station for QC testing and R&D
flexibility; or an analog recorder.
Fully configured packages include reverse-phase C-18 column, solvent
delivery system, syringe and detector.
Variable wavelength systems give hi-resolution selectivity [5nm] from 190-
360nm (D2) and 360-800nm (Tungsten).
Wide selection of reverse-phase (C-18, C-8, Amino, Cyano, Phenyl),
normal (SiO2 & Al203) and GPC columns available.
Completely bio-compatible contact surfaces in All-Polymer design
(PEEK, Teflon, Ruby, Sapphire, Quartz) eliminates Ionic contamination,
with stainless steel option for high-pressure and GPC/SEC work.
Precision electronic Pump Control from 0.01-9.99ml/min (Analytical) and
0.10-40.0ml/min (Semi-Preparative)
Detector flowcells quickly changed from Analytical (7mm pathlength /
10 L) to Preparative (2mm pathlength / 4L).
Suitable for any HPLC application from cosmetics, foods, pharmaceuticals
and education; to paints, & pigments, polymers, petrochemicals and
botanicals.
The basic BLC-10 series HPLC
systems have a very sensitive
and stable filter photometer for
routine assays at the most
common wavelengths. The
BLC-10 comes equipped with a
254nm fixed wavelength filter
photometer. The BLC-10 can also
accomodate a filter for the following
wavelengths; 280, 365, 420, 505 &
540nm. The BLC-10 comes
complete with a column, fittings, a
pump and injector hardware for
instant setup and analyses.
BLC-10
For more information
call 800-562-5566
or Click www.bucksci.com
Software
All Chromatography instruments from Buck are easily and fully controlled
by the PeakSimple Software package; directly or through a DataStation.
Control of data collection, external switches, detector response range and
auto-zero, and pump flow can all be set in the program for instant
reloading; thus simplifying method development. Complete access to the
data files, calibration parameters and report format provides full
documentation of test protocols. Variable integration windows, multi-point
polynomial calibration and up to 4-channel inputs make the PeakSimple
package more powerful than systems costing 10X as much!
BLC-20 Variable Wavelength HPLC:
PUMP
Flow Rate 0.01-9.99ml/min (Ana)
0.10-40ml/min (PREP)
Pressure 0-3000PSI max (PEEK)
0-5000PSI max (SS)
Accuracy 1% MAX deviation
Presicion <0.5% RSD
Panel Controls Run/Stop & Prime
Flow Control & Pump Status
Display Flow rate [ml/min]
DETECTOR =
Wavelength Range 190-360nm. UV [D2 Lamp]
360-800nm. VIS [W Lamp]
Bandpass [Res] 5nm.
Flowcell 10uL Volume, 7mm. Path (ANA)
4uL Volume, 2mm. Path (PREP)
ABS Range 0.005 to 1.0 ABS [2ABS MAX]
Drift <2 x 10-4 A/hour @ 254nm.
Noise <2 x 10-5 A @ 254nm.
Linearity >2%
Panel Controls ABS Range, Auto-Zero, WL
Wavelength Accuracy Better than 2nm.
Reproducibility Better than 1nm.
Recorder Output 10mV full-scale
Integrator Output 1V/ABS to 2V (=2.0ABS)
Display ABS: 4.5 digits to 1.999ABS
Wavelength: 3 digits
Shipping Weight 40 lbs.
Dimensions 16W x 7H x 17D
BLC-20G GRADIENT HPLC:
PUMP
Flow Rate 0.01-9.99ml/min (Ana)
0.10-40ml/min (PREP)
Pressure 0-3000PSI max (PEEK)
0-5000PSI max (SS)
Accuracy 1% MAX deviation
Presicion <0.5% RSD
BUCK-CHROM CONTROLLER
Gradient Range 0-100%
Increments 0.5%
Gradient Accuracy 1% MAX deviation
Precision < 1% variation from
10%-90%
Flow Accuracy (2-pump) 1% MAX deviation
Precision (2-pump) <0.5% RSD
Software Controls Wavelength, Min/Max Pressure
Limits, Sample ID, Solvent and
ColumnSpecs, Flow, Gradient
Ramps, Signal Processing for
2 Detectors, Relay Controls for
Fraction Collector & Auto-
sampler
Software Displays Real-Time Detector signal(s)
and Pressure readings,
chromatograms, gradient &
Pressure Curves (graphical)
Phone: 203-853-9444 FAX: 203-853-0569 ~ E-Mail: sales@bucksci.com Homepage: www.bucksci.com
BLC-20 display
shows full range of
controls
BLC-10 components
are fully integrated
Hardware Specifications