3 Digit General Purpose Clamp Meters

This meter provides average sensing measurement, rugged construction,
easy & single-handed operation and reliable performance indispensable to
troubleshoot various general electrical problems.

Features:
Rugged, Easy & Single-Handed operational, and Reliable.
Protective Hand Guard to prevent an accidental contact with
conductor.
Frequency measurement capability.
Average sensing clamp meter.
Surge (Transient) voltage protection.
Peak hold & DC A Zero Adjustment thumbwheel.
Low-Battery annunciator.
Maximum conductor size: 1 ea 38mm (1.5").

Accessories:
Battery, 9V (BT1)
Test Lead Set (FTl-500)
Alligator Clips (AC7)
Carrying Case (C110)

Standards
IEC 010-2-032
EMC Directive
UL 3111-1
CAN/CSA C22.2 No. 1010.1-92
ISA-DS 82






FinestCaltek
Dueto our policy of continual product development wereservetheright to amend thespecifications of all mentioned products without notice.
Finest 113_PF_v02
Created on 12/8/2005 12:54:13 PM
Prepared by Fung Page2 of 3

Electrical Specification
Accuracy is given as ([% of reading] +[number of digits]) at 18C to 28C with relative humidity up to 80%, for
a period of one year after calibration. AC conversions of this Meter are average responding calibrated to the RMS
value of a sine wave input.

DC Current Measurement
Range Resolution Accuracy Overload Protection
1000A 1A (2.0% Read. +10dgt)
400A 0.1A (1.5% Read. +5dgt)
1000A Continuous

AC Current Measurement
Range Resolution Accuracy Overload Protection
1000A 1A (2.5% Read. +10dgt)
400A 0.1A (2.0% Read. +5dgt)
1000A Continuous

DC Voltage Measurement
Range Resolution Accuracy Overload Protection
600V 1V (1.0% Read. +3dgt)
400V 0.1V (0.5% Read. +3dgt)
600V RMS

AC Voltage Measurement (50-400Hz)
Range Resolution Accuracy Overload Protection
600V 1V (1.2% Read. +5dgt)
400V 0.1V (1.0% Read. +3dgt)
600V RMS

Ohms Measurement
Range Resolution Accuracy Overload Protection
400 0.1 (1.0% Read. +5dgt) 600V

Continuity Test
Open Circuit Test <1.2V
Buzzer 40

Frequency
Range Resolution Accuracy Overload Protection
4MHz 1kHz (1.0% Read. +5dgt)
400kHz 100Hz
40 kHz 10Hz
4 kHz 1Hz
(0.5% Read. +3dgt)
600 V









FinestCaltek
Dueto our policy of continual product development wereservetheright to amend thespecifications of all mentioned products without notice.
Finest 113_PF_v02
Created on 12/8/2005 12:54:13 PM
Prepared by Fung Page3 of 3

General Specifications

Display : 3 3/4 digits LCD with max. reading of 4000.
Polarity : Automatic, (-) negative polarity indication.
Zero adjustment : Automatic.
Over range indication : Only the MSD OL is displayed.
Operating Temperature : 0C to 45C
Operating Humidity : <80% RH
Storage Temperature : -20C to 60C
Max J aw Opening : 32mm (1.25)
Power : Single standard 9 volt battery NEDA 1604, IEC 6LR61
Dimension : 85 (W) x 208 (H) x 34 (D) mm.
Weight : Approx. 380 g.





























Hong Kong:
Flat E, 12/F., Effort Industrial Bldg.,
2-8 Kung Yip Street, Kwai Chung,
N.T., Hong Kong
Tel: (852) 2401-1222
Fax: (852) 2420-3472
Email: caltek@caltek.com.hk
Si ngapore :
Level 15, Suite 27,
Prudential Tower, 30 Cecil Street,
Singapore 049712
Tel: (65) 6232 2903
Fax: (65) 6232 2888
Email: sales_sg@caltek.com.hk
Chi na (Guangzhou):
Tel: (86-20) 3493 6162
Fax: (86-20) 3493 6163
Email: sales_cn@bstcaltek.com
4/F., Li Zhi Wan, Zhen Xing Road,
Dagang Town, PanYu,
GuangZhou, China.
CALTEK INDUSTRIAL (H.K.) LTD.

Das könnte Ihnen auch gefallen