Sie sind auf Seite 1von 32

Industrial

Cable Index
Industrial
Cable
n DLO Power Cables
DLO Flexible Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-3
n Type W Cables
Type W 1/C Motor Lead Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
Type W 2/C Magnet Crane Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6-7
Type W 3/C P&R Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8-9
Type W 4/C P&R Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10-11
n Variable Frequency Drive (VFD) Power Cables
Extra Flexible VFD Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12-13
CIR (Crush & Impact Resistant) VFD Power Cable . . . . . . . . . . . . . . . . . 14-15
TC-ER Flexible VFD Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16-17
Medium Voltage Type VFD/MV-105 Power Cable . . . . . . . . . . . . . . . . . . 18-19
n Ship-to-Shore Power Cables
Enhanced THOF-500 Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Enhanced PLUS THOF-500 Power Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21
n Grounds and Jumpers
Flexible Grounding Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22
Lead Covered Grounding Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23
Red Jumper . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24-25
n Mobile Substation Power Cable (Type SH) . . . . . . . . . . . . . . . . . . . . . . . . . 26-27
n Factory Installed Cable Assemblies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28
n Renewable Energy Cables . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Nexans AmerCable believes the information presented throughout this catalog to be reliable and current.
All information is subject to change without notice. The information listed is approximate, and is
presented only as a guide for product selection. We make no claims or warranties for the suitability
of any product for any particular application.
AmerCable

is a registered trademark of AmerCable Incorporated


Made in America
2013, AmerCable Incorporated
Index
www.NexansAmerCable.com
Harsh operating
environments
require cables
engineered for
longer service life
No matter what type of environment you operate in,
Nexans AmerCable has a cable productivity solution
for you. Our innovatively engineered and manufactured
Industrial Cable Family is designed for your
toughest conditions. As a leading producer of
industrial cables in North America, Nexans AmerCable
is dedicated to producing:
n cables that last longer in difficult
operating environments
n cables designed to help provide greater
levels of safety and productivity
Cable Innovation
n Designing insulating and jacketing materials that
are more flexible with greater resistance to
abrasion and moisture
n Cable constructions that last longer providing
reduced down time for increased productivity
n New product development that addresses
environmental, safety and cost reduction
issues specific to your application.
Operating Excellence
n The industry leader in on-time
delivery. For our current
delivery rate, visit
our website at
www.amercable.com
n Standard lead-time
of 8 to 10 weeks
n Urgent response
shipment capability
of 2 to 4 weeks
n AmerCable is an ISO-9001
certified manufacturer
Hands-on Field Support
Our experienced field application engineers are
available for on-site evaluation and solutions.
They also conduct education and training
sessions that address safety, splicing and
cable handling issues.
1
e-mail: industrial@nexansamercable.com
37-119
Flexible Power Cable DLO
2000 Volts 90C
Diesel Locomotive Cable Limited Smoke (Sizes 2/0 and higher) EP/CPE RHH, RHW-2
Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613
2
Application
Nexans AmerCables 2000V Diesel Locomotive
Cable (DLO) is a single conductor portable
power cable suitable for use in applications
needing great flexibility, excellent wearability
and good flex life. Applications include
locomotive and car equipment, motor and
generator leads, battery leads, shipyards,
telecommunications power, heavy earth
moving equipment, renewable energy and
other heavy duty flexing applications.
Features
n A two layer composite of flame retardant,
oil and sunlight resistant Chlorinated
Polyethylene (CPE) outer layer and Ethylene-
Propylene rubber (EPR) inner layer. The
composite design provides significant
diameter reductions compared to designs
using full thickness jackets.
n Suitable for continuous operating
temperatures of 90C, wet or dry
n Rated RHH, RHW-2; 2/0 1111 kcmil
listed and marked for CT use
n UL listed as Sunlight Resistant
n UL listed as Marine Shipboard Cable
(4/0 and larger) Special order only
n Insulation and jacket meet hazardous
waste regulations, per Code of Federal
Regulations 40 Section 261 (40CFR261)
for characteristic lead content
n Flame Resistance: FT-4/IEEE1202 for
2/0 1111 kcmil and UL VW-1
n Meets smoke release and other
requirements of Vertical Cable Tray
Test UL 1685 and is marked ST-1
for 2/0 1111 kcmil
n Extremely flexible stranding used for
increased flexibility and ease of installation
Insulation
Ethylene-Propylene rubber
(EPR)
Jacket
Flame retardant,
oil and sunlight
resistant
Chlorinated
Polyethylene (CPE)
See below
for jacket
color options
(Special order)
Conductor
Flexible-stranded,
tin-coated annealed
copper
Separator
Suitable separator tape
provides easy stripping
of insulation
Ratings & Approvals
n ICEA S-95-658/ NEMA WC-70: Nonshielded Power
Cables Rated 2000 Volts or Less for the
Distribution of Electrical Energy
n UL Standard 44: Thermoset Insulated Wires &
Cables, Types RHH, RHW-2. UL VW-1
n UL Standard 1685: Vertical Tray Fire propagation
and Smoke Release Test for Electrical and
optical Fiber Cables. (UL,ST-1)
n ASTM B-33: Standard Specification for Tinned Soft
or Annealed Copper Wire for Electrical Purposes
n ASTM B-172: Standard Specification for
Rope-Lay-Stranded Copper Conductors having
Bunch-Stranded Members, for Electrical
Conductors
n MSHA P-184
n RoHS Compliant
www.nexansamercable.com e-mail: industrial@nexansamercable.com
3
37-119 Single Conductor Portable Power Cable DLO
201 14 19 0.045 0.015 0.214 31 35
202 12 19 0.045 0.015 0.233 41 40
203 10 37 0.045 0.015 0.257 58 55
204 8 168 0.055 0.030 0.349 77 80
205 6 61 0.055 0.030 0.365 124 105
207 4 133 0.055 0.030 0.460 203 140
209 2 259 0.055 0.030 0.534 265 190
210 1 224 0.065 0.045 0.623 415 220
211 1/0 266 0.065 0.045 0.668 489 260
212 2/0 323 0.065 0.045 0.689 562 300
213 3/0 418 0.065 0.045 0.771 757 350
214 4/0 532 0.065 0.045 0.822 894 405
215 262 646 0.075 0.065 0.957 1091 467
216 313 777 0.075 0.065 1.008 1245 522
217 373 925 0.075 0.065 1.074 1486 591
218 444 1110 0.075 0.065 1.143 1749 652
219 535 1332 0.090 0.065 1.257 2099 728
220 646 1591 0.090 0.065 1.361 2464 815
221 777 1924 0.090 0.065 1.439 2899 904
222 929 2318 0.090 0.065 1.685 3501 1005
223 1111 2745 0.130 0.065 1.850 4166 1119
*
Ampacity Calculated with at 90C conductor
temperature and 30C ambient air, per
2008 NEC, Table 310.17
Cable diameters are subject to +/-5% manufacturing
tolerance
Approx.
Weight
lbs. per
1,000 ft.
*Ampacity
90C
Part No.
37-119-
Size
AWG/
kcmil
Minimum
Wires per
Conductor
Nominal
Insulation
Thickness
in.
Nominal
Jacket
Thickness
in.
Nominal
Outside
Diameter
in.
Order Your DLO Cable with
Factory Installed
Connectors
SAVE
TIME
SAVE
MONEY
37-401
Portable Power Cable Type W
Single Conductor 600-2000 Volts
Motor Lead Cable 90C
Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613
4
Application
Nexans AmerCables 600-2000 Volt
single-conductor motor-lead cables are
recommended for installations where long
flex life, great flexibility and wearability are
desired. Applications include heavy duty or
temporary power supply service, AC or DC,
to motor or generators, portable and
stationary heavy duty equipment, cranes,
conveyors and other mobile equipment.
They may be installed in air, in ducts,
immersed in water or directly buried in the
earth. However, they are not UL Type USE.
For cables requiring reduced flame
propagation, refer to the factory.
Features
n Suitable for continuous operating
temperatures of 90C
n Suitable for use in festoons, suspended
loops and power tracks
n Suitable for use on Payout and
Retractable reels (P&R)
n Heavy duty jacket offers excellent
protection against abrasion, impact, heat,
oil, flame, ozone, alkali and acids.
n Extremely flexible stranding used for
increased flexibility and ease of installa-
tion
n Dual Rated 600V and 2kV
n Suitable for extra hard usage which
enhances performance
Jacket
Flame retardant, oil
and sunlight resistant
Chlorinated Polyethylene
(CPE). Black standard.
See below for other
color options.
Conductor
Bunched strands of tinned
annealed copper per ASTM
B-33
Insulation
Ethylene-Propylene rubber
(EPR) per ICEA S-95-658,
and ASTM D-2802
Separator
A suitable separator
provides for easy stripping
of insulation
Ratings & Approvals
n UL listed as Type W
n ASTM B-33: Standard Specification for Tinned Soft
or Annealed Copper Wire for Electrical Purposes
n ASTM D-2802: Standard Specification for Ozone-
Resistant Ethylene-Alkene Polymer Insulation for
Wire and Cable
n ICEA S-95-658/ NEMA WC-70: Nonshielded Power
Cables Rated 2000 Volts or Less for the Distribution
of Electrical Energy
n MSHA P-184 for 6 AWG and above
Type W CPE jackets are available in highly visible colors
without sacrificing performance
Reinforcement
Polypropylene reinforcing
braid provides long
flex life
www.nexansamercable.com e-mail: industrial@nexansamercable.com
5
37-401 Single Conductor Portable Power Cable Type W
008 8 133 0.060 0.075 0.460 136 80
006 6 133 0.060 0.095 0.550 202 105
004 4 133 0.060 0.095 0.600 268 140
003 3 133 0.060 0.095 0.620 318 165
002 2 259 0.060 0.095 0.690 375 190
001 1 259 0.080 0.095 0.760 479 220
010 1/0 266 0.080 0.095 0.810 555 260
020 2/0 323 0.080 0.095 0.832 675 300
030 3/0 418 0.080 0.095 0.900 794 350
040 4/0 532 0.080 0.095 0.960 959 405
250 250 627 0.095 0.095 1.070 1268 455
300 300 741 0.095 0.095 1.100 1315 505
350 350 888 0.095 0.095 1.160 1517 570
400 400 999 0.095 0.095 1.190 1681 615
500 500 1221 0.095 0.095 1.310 2039 700
* Ampacity is calculated with a 90C conductor temperature and 30C ambient air,
per 2008 NEC, Table 400.5(B)
Cable diameters and weights are subject to +/- 5% manufacturing tolerance
Approx.
Weight
lbs. per
1,000 ft.
*Ampacity
90C
Part No.
37-401-
Size
AWG/
kcmil
Minimum
Wires per
Conductor
Nominal
Insulation
Thickness
in.
Nominal
Jacket
Thickness
in.
Nominal
Outside
Diameter
in.
Order Your Type W Cable with
Factory Installed
Connectors
SAVE
TIME
SAVE
MONEY
37-430
Magnet Crane Cable Type W
Two Conductor 600-2000 Volts
Magnet Crane Cable 90C
Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613
6
Application
Nexans AmerCables 600-2000 Volt two
conductor cables are recommended for
installations where long flex life, great
flexibility and wearability are desired.
Applications include heavy duty or temporary
power supply service, AC or DC, to motor or
generators, portable and stationary heavy
duty equipment, cranes, conveyors and
other mobile equipment. They are especially
recommended to supply power for magnet
crane applications. They may be installed in
air, in ducts, immersed in water or directly
buried in the earth. However, they are not
UL Type USE. For cables requiring reduced
flame propagation, refer to the factory.
Features
n Suitable for continuous operating
temperatures of 90C
n Suitable for use in festoons, suspended
loops and power tracks
n Suitable for use on Payout and
Retractable reels (P&R)
n Heavy duty jacket offers excellent
protection against abrasion, impact, heat,
oil, flame, ozone, alkali and acids.
n Extremely flexible stranding used for
increased flexibility and ease of installa-
tion
n Dual Rated 600V and 2kV
n Suitable for extra hard usage which
enhances performance
Ratings & Approvals
n UL listed as Type W
n UL listed as Type TC
n ASTM B-33: Standard Specification for Tinned Soft
or Annealed Copper Wire for Electrical Purposes
n ASTM D-2802: Standard Specification for Ozone-
Resistant Ethylene-Alkene Polymer Insulation for
Wire and Cable
n ICEA S-95-658/ NEMA WC-70: Nonshielded Power
Cables Rated 2000 Volts or Less for the Distribution
of Electrical Energy
n MSHA P-184
n Flame Resistance: FT-4
Separator
A suitable separator
provides for easy
stripping of insulation
Conductors
Bunched strands of
tinned annealed copper
per ASTM B-33. Stranding
other than those listed in
the table are available
upon special order.
Fillers
Fibrous filler provides
great impact resistance
and flexibility. Rubber fillers
are available upon special
order.
Jacket
Flame retardant, oil and
sunlight resistant Chlorinated
Polyethylene (CPE).
Black standard. See below
for other color options.
Insulation
Ethylene-Propylene
rubber (EPR) per ICEA
S-95-658 and ASTM
D-2802. Insulation
material color coded
through AWG size #2.
Larger sizes are coded
with fabric tape wraps.
One black, one white.
Type W CPE jackets are available in highly visible colors
without sacrificing performance
www.nexansamercable.com e-mail: industrial@nexansamercable.com
7
37-430 Two Conductor Magnet Crane Type W Round
008 8 133 0.060 0.109 0.830 369 74
006 6 133 0.060 0.109 0.960 518 99
004 4 133 0.060 0.109 1.080 715 130
002 2 259 0.060 0.141 1.280 1045 174
010 1/0 266 0.080 0.156 1.560 1464 234
020 2/0 342 0.080 0.156 1.660 1788 271
040 4/0 532 0.080 0.172 1.973 2530 361
250 250 627 0.095 0.165 2.100 2664 402
350 350 888 0.095 0.176 2.360 3854 495
500 500 1221 0.095 0.214 2.700 5191 613
* Ampacity is calculated with a 90C conductor temperature and 30C ambient air,
per 2008 NEC, Table 400.5(B)
Cable diameters and weights are subject to +/- 5% manufacturing tolerance
A full line of UL listed Type G cables with grounding conductors is
available. Consult factory.
Approx.
Weight
lbs. per
1,000 ft.
*Ampacity
90C
Part No.
37-430-
Size
AWG/
kcmil
Minimum
Wires per
Conductor
Nominal
Insulation
Thickness
in.
Nominal
Jacket
Thickness
in.
Nominal
Outside
Diameter
in.
Photo provided by NASCOOP
Order Your Type W Cable with
Factory Installed
Connectors
SAVE
TIME
SAVE
MONEY
37-431
Portable Power Cable Type W
Three Conductor 600-2000 Volts
Qualified for P&R Reeling Service 90C
Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613
8
Application
Nexans AmerCables 600-2000 Volt three
conductor cables are recommended for
installations where long flex life, great flexi-
bility and wearability are desired.
Applications include heavy duty or temporary
power supply service, AC or DC, to motor
or generators, portable and stationary heavy
duty equipment, cranes, conveyors and
other mobile equipment. They are also
recommended for use on Payout and
Retractable reels, festoons, suspended
loops and power tracks. They may be
installed in air, in ducts, immersed in water
or directly buried in the earth. However, they
are not UL Type USE. For cables requiring
reduced flame propagation, refer to
the factory.
Features
n Suitable for continuous operating
temperatures of 90C
n Suitable for use in festoons, suspended
loops and power tracks
n Suitable for use on Payout and
Retractable reels (P&R)
n Heavy duty jacket offers excellent
protection against abrasion, impact, heat,
oil, flame, ozone, alkali and acids.
n Extremely flexible stranding used for
increased flexibility and ease of installa-
tion
n Dual Rated 600V and 2kV
n Suitable for extra hard usage which
enhances performance
n Meets crush and impact
requirements
Separator
A suitable separator
provides for easy stripping
of insulation
Jacket
Flame retardant, oil
and sunlight resistant
Chlorinated Polyethylene
(CPE). Reinforced, two
layer jacket construction
is used on AWG size 1/0
and larger cables. Black
standard. Consult factory
for colored jackets.
Conductors
Bunched strands of tinned
annealed copper per ASTM
B33. Stranding other than
those listed in the table are
available upon special
order.
Insulation
Ethylene-Propylene rubber
(EPR) per ICEA S-95-658,
also meeting ASTM D-
2802. Insulation material
color coded through AWG
size #2. Larger sizes are
coded with fabric tape
wraps. One black, one
white, one green.
Ratings & Approvals
n UL listed as Type W
n UL listed as Type TC-ER
n ASTM B-33: Standard Specification for Tinned Soft
or Annealed Copper Wire for Electrical Purposes
n ASTM D-2802: Standard Specification for Ozone-
Resistant Ethylene-Alkene Polymer Insulation for
Wire and Cable
n ICEA S-95-658/ NEMA WC-70: Nonshielded Power
Cables Rated 2000 Volts or Less for the Distribution
of Electrical Energy
n MSHA P-184
n Flame Resistance: FT-4
Fillers
Fibrous filler provides
great impact resistance
and flexibility. Rubber
fillers are available upon
special order.
Reinforcement
Polypropylene reinforcing
braid provides long
flex life
UL Type
TC-ER
APPROVED!
Type W CPE jackets are available in highly visible colors
without sacrificing performance
www.nexansamercable.com e-mail: industrial@nexansamercable.com
9
37-431 Type W Round 600-2000 Volts
008 8 133 0.060 0.141 0.930 513 65
006 6 133 0.060 0.141 1.025 643 87
004 4 133 0.060 0.125 1.200 962 114
002 2 259 0.060 0.141 1.340 1295 152
010 1/0 266 0.080 0.156 1.665 1967 205
020 2/0 323 0.080 0.156 1.75 2260 237
030 3/0 418 0.080 0.156 1.900 2863 274
040 4/0 532 0.080 0.172 2.050 3381 316
250 250 627 0.095 0.250 2.395 4375 352
350 350 888 0.095 0.259 2.684 5562 433
500 500 1221 0.095 0.290 3.030 7408 536
* Ampacity is calculated with a 90C conductor temperature and 30C ambient air,
per 2008 NEC, Table 400.5(B)
Cable diameters and weights are subject to +/- 5% manufacturing tolerance
A full line of UL listed Type G cables with grounding conductors is
available. Consult factory.
Approx.
Weight
lbs. per
1,000 ft.
*Ampacity
90C
Part No.
37-431-
Size
AWG/
kcmil
Minimum
Wires per
Conductor
Nominal
Insulation
Thickness
in.
Nominal
Jacket
Thickness
in.
Nominal
Outside
Diameter
in.
Order Your Type W Cable with
Factory Installed
Connectors
SAVE
TIME
SAVE
MONEY
37-432
Portable Power Cable Type W
Four Conductor 600-2000 Volts
Suitable for P&R Reeling Service 90C
Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613
10
Application
Nexans AmerCables 600-2000 Volt four
conductor cables are recommended for
installations where long flex life, great
flexibility and wearability are desired.
Applications include heavy duty or temporary
power supply service, AC or DC, to motor or
generators, portable and stationary heavy
duty equipment, cranes, conveyors and other
mobile equipment. They are also recommended
for use on Payout and Retractable reels,
festoons, suspended loops and power
tracks. They may be installed in air, in ducts,
immersed in water or directly buried in the
earth. However, they are not UL Type USE.
For cables requiring reduced flame
propagation, refer to the factory.
Features
n Suitable for continuous operating
temperatures of 90C
n Suitable for use in festoons, suspended
loops and power tracks
n Suitable for use on Payout and
Retractable reels (P&R)
n Heavy duty jacket offers excellent
protection against abrasion, impact,
heat, oil, flame, ozone, alkali and acids
n Extremely flexible stranding used for
increased flexibility and ease of installa-
tion
n Dual Rated 600V and 2kV
n Suitable for extra hard usage which
enhances performance
n Meets crush and impact
requirements
for Type MC cable.
Separator
A suitable separator
provides for easy stripping
of insulation
Jacket
Flame retardant, oil
and sunlight resistant
Chlorinated Polyethylene
(CPE). Black standard.
Consult factory for
colored jackets.
Conductors
Bunched strands of tinned
annealed copper per ASTM
B-33. Strandings other than
those listed in the table
are available upon
special order.
Reinforcement
Polypropylene reinforcing
braid provides long flex life
Insulation
Ethylene-Propylene rubber
(EPR) per ICEA S-95-658,
also meeting ASTM D-
2802. Insulation material
color coded through AWG
size #2. Larger sizes are
coded with fabric tape
wraps. One black, one red,
one white, one green.
Ratings & Approvals
n UL listed as Type W
n UL listed as Type TC-ER
n ASTM B-33: Standard Specification for Tinned Soft
or Annealed Copper Wire for Electrical Purposes
n ASTM D-2802: Standard Specification for Ozone-
Resistant Ethylene-Alkene Polymer Insulation for
Wire and Cable
n ICEA S-95-658/ NEMA WC-70/: Nonshielded
Power Cables Rated 2000 Volts or Less for
the Distribution of Electrical Energy
n MSHA P-184
n Flame Resistance: FT-4
Fillers
Fibrous filler
provides great impact
resistance and
flexibility. Rubber
fillers are available
upon special order.
UL Type
TC-ER
APPROVED!
Type W CPE jackets are available in highly visible colors
without sacrificing performance
www.nexansamercable.com e-mail: industrial@nexansamercable.com
11
37-432 Four Conductor Portable Power Cable Type W Round
008 8 133 0.060 0.141 1.020 601 65
006 6 133 0.060 0.141 1.135 801 87
004 4 133 0.060 0.125 1.240 1138 114
002 2 259 0.060 0.125 1.490 1663 152
010 1/0 266 0.080 0.156 1.810 2471 205
020 2/0 323 0.080 0.156 1.940 2975 237
040 4/0 532 0.080 0.156 2.260 4376 316
250 250 627 0.095 0.270 2.665 5725 352
350 350 888 0.095 0.290 3.000 7428 433
500 500 1221 0.095 0.310 3.425 10010 536
* Ampacity is calculated with a 90C conductor temperature and 30C ambient air, per
2008 NEC, Table 400.5(B)
Cable diameters and weights are subject to +/- 5% manufacturing tolerance
For more than four conductors, consult factory
A full line of UL listed Type G cables with grounding conductors is
available. Consult factory.
Approx.
Weight
lbs. per
1,000 ft.
*Ampacity
90C
Part No.
37-432-
Size
AWG/
kcmil
Minimum
Wires per
Conductor
Nominal
Insulation
Thickness
in.
Nominal
Jacket
Thickness
in.
Nominal
Outside
Diameter
in.
Order Your Type W Cable with
Factory Installed
Connectors
SAVE
TIME
SAVE
MONEY
37-102VFD
Standard VFD Power Cable
Gexol

Insulated
Three Conductor 2kV Rated 110C
Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613
12
Application
A flexible, braid and foil shielded, 2kV power
cable specifically engineered for use in variable
frequency AC motor drive (VFD) applications.
Features
n Specially engineered cable design produces a
longer cable life in VFD applications.
n Overall braid plus foil shield is engineered
with 100% coverage and a surface transfer
impedance <50 milliohms at 10MHz to
contain EMI.
n Symmetrical insulated ground conductors
reduce induced voltage imbalances and carry
common mode noise back to the drive.
n High strand count conductors and braid
shield design is much more flexible, easier
to install and more resistant to vibration
than Type MC cable.
n Gexols lower dielectric constant (standard
XLPEs, EPRs and other Type P insulation
materials have higher dielectric constants)
reduces reflected wave peak voltage
magnitudes. This allows for longer output
cable distances and minimizes the effect
of high frequency noise induced into the
plant ground system.
n 2kV insulation thickness is used to resist the
potential 2-3x reflected voltages experienced
in 600V VFD applications.
n Dual certified IEEE 1580 Type P and
UL 1309/CSA 245 Type X110.
n Highest ampacity ratings: ABS 100C, DNV
95C, LRS 95C, Transport Canada 95C.
n Severe cold durability: exceeds CSA cold
bend/cold impact (-40C/-35C).
n Flame retardant: IEC 332-3 Category A
and IEEE 1202.
n Suitable for use in Class I, Division 1 and Zone
1 environments (armored and sheathed).
n Optional braid armor of bronze, aluminum
or tinned copper.
Jacket
A black, arctic grade, flame
retardant, oil, abrasion,
chemical and sunlight
resistant thermosetting
compound meeting UL1309/
CSA 245 and IEEE 1580.
Power Conductors (x3)
Soft annealed flexible stranded
tinned copper per IEEE 1580
Table 11.
Shield
Overall tinned copper braid
plus aluminum/polyester
tape providing 100%
coverage.
Armor (Optional)
Tinned copper basket weave
wire armor per IEEE 1580
and UL 1309/CSA 245.
Ratings & Approvals
n 110C Temperature Rating
n American Bureau of Shipping (ABS)
n Transport Canada2
n Det Norske Veritas (DNV)
n Lloyds Register of Shipping (LRS): 09/00023
n NVE: 95/1696, FAL
n UL Listed as Marine Shipboard Cable: (E111461)
n Unarmored Cable is UL Listed as Type TC (E123629)
n United States Coast Guard: November 2, 1987 / 9304
Other certifications pending
Ground Conductors (x3)
Soft annealed flexible
stranded tinned copper per
IEEE 1580 Table 11.
Gexol

insulated and
sized per UL 1277.
Color: Green
Insulation (2kV)
Gexol

cross-linked flame
retardant polyolefin, meeting
the requirements for Type P
of IEEE 1580 and Type X110
of UL 1309/CSA 245.
Color: Gray with printed
phase I.D. (Black-White-Red)
Note: For armored versions the braid is placed between
the inner jacket and outer sheath where it serves
as both the EMI shield and armor.
Sheath (Optional)
A black, arctic grade,
flame retardant, oil,
abrasion, chemical and
sunlight resistant
thermosetting compound
meeting UL 1309/CSA 245
and IEEE 1580.
Gexol

is a registered trademark of AmerCable Incorporated


www.nexansamercable.com e-mail: industrial@nexansamercable.com
13
37-102VFD VFD Power Cable Gexol

Insulated
*Cable diameters are subject to a +/- 5% manufacturing tolerance
**3 Grounding Conductors Green Insulated
Unarmored Armored & Sheathed (TS)
DC Resist. AC Resist. Inductive Voltage Drop Grounding
Size Nominal Weight Nominal Weight at 25C at 90C, Reactance at 90C Conductor**
AWG/ Part No. Diameter Lbs./ Part No. Diameter Lbs./ Ohms/ 60 Hz Ohms/ Ohms/ Volts/Amp/ Size
kcmil mm
2
37-102 Inches* 1000 Ft. 37-102 Inches* 1000 Ft. 1000 Ft. 1000 Ft. 1000 Ft. 1000 Ft. (AWG) 110C 100C 90C 75C
4 21 -312VFD 1.100 925 -312TSVFD 1.262 1138 0.300 0.399 0.031 0.584 12 99 92 83 70
2 34 -314VFD 1.235 1421 -314TSVFD 1.392 1512 0.184 0.244 0.029 0.368 10 131 122 111 93
1 43 -315VFD 1.340 1517 -315TSVFD 1.509 1851 0.147 0.195 0.029 0.301 10 153 143 131 110
1/0 54 -316VFD 1.450 1803 -316TSVFD 1.615 2136 0.117 0.156 0.029 0.246 10 176 164 150 126
2/0 70 -317VFD 1.580 2120 -317TSVFD 1.792 2660 0.093 0.125 0.028 0.202 10 201 188 173 145
3/0 86 -318VFD 1.750 2827 -318TSVFD 1.959 3269 0.074 0.100 0.028 0.167 8 234 218 200 168
4/0 109 -319VFD 1.900 3416 -319TSVFD 2.101 3864 0.058 0.080 0.027 0.139 8 270 252 232 194
262 132 -320VFD 2.050 4210 -320TSVFD 2.258 4661 0.048 0.067 0.027 0.120 6 315 294 273 228
313 159 -321VFD 2.130 5105 -321TSVFD 2.353 5325 0.040 0.056 0.026 0.105 6 344 321 298 249
373 189 -322VFD 2.275 5521 -322TSVFD 2.483 6674 0.034 0.047 0.025 0.092 6 387 361 332 277
444 227 -323VFD 2.425 6440 -323TSVFD 2.634 6994 0.028 0.041 0.025 0.083 6 440 411 382 319
535 273 -324VFD 2.643 7547 -324TSVFD 2.931 8477 0.024 0.035 0.026 0.075 6 498 443 407 340
646 326 -326VFD 2.920 8916 -326TSVFD 3.178 9888 0.020 0.030 0.026 0.068 4 553 516 474 396
777 394 -327VFD 3.102 10909 -327TSVFD 3.510 11803 0.016 0.026 0.025 0.062 4 602 562 516 431
Ampacity
Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613
37-102 CIRVFD
CIR

(Crush & Impact Resistant) VFD Power Cable


Gexol

Insulated
Three Conductor 2kV Rated 90C UL Listed as Type TC-ER
14
Application
A flexible, braid and foil shielded, 2kV power
cable specifically engineered for use in variable
frequency AC motor drive (VFD) applications.
Features
n Specially engineered cable design produces
a longer cable life in VFD applications.
n Overall braid plus foil shield is engineered
with 100% coverage and a surface transfer
impedance <50 milliohms at 10MHz to
contain EMI.
n Symmetrical insulated ground conductors
reduce induced voltage imbalances and carry
common mode noise back to the drive.
n High strand count conductors and braid
shield design is much more flexible, easier
to install and more resistant to vibration
than Type MC cable.
n Gexols lower dielectric constant (standard
XLPEs, EPRs and other Type P insulation
materials have higher dielectric constants)
reduces reflected wave peak voltage
magnitudes. This allows for longer output
cable distances and minimizes the effect
of high frequency noise induced into the
plant ground system.
n 2kV insulation thickness is used to resist the
potential 2-3x reflected voltages experienced
in 600V VFD applications.
n Passes the same stringent crush and impact
testing required by UL 2225 for Type MC-HL
n Gas & vapor tight impervious to water
and air
n Smaller bend radius (up to 40% smaller)
than Type MC
n Reduced tray fill (up to 35% less) compared
to Type MC
n Considerably more flexible than Type MC
n Reduced installation time and cost compared
to Type MC
n Glands for this product cost up to 50% LESS
than those for Type MC
Insulation
Gexol

chemically cross-
linked, non-chlorinated
flame retardant polyolefin
meeting the requirements
per UL 1277.
Color: Gray with printed
phase I.D.
Jacket
Crush & impact
resistant, flame
retardant, oil, abrasion,
chemical and
sunlight resistant
thermoplastic
compound meeting
UL 1277.
Power Conductors (x3)
Soft annealed flexible
stranded tinned copper
per ASTM B-33.
Ground
Conductors (x3)
Soft annealed tinned copper
per ASTM B-33 flexible
stranding with 600/1000V
Gexol

insulation sized per


UL 1277. Color: Green
Shield
Overall tinned copper braid
plus aluminum/polyester
tape providing 100%
coverage.
Safe to Handle
CIR

is a safe,
flexible alternative to
metal-clad cables.
Gexol

and CIR

are registered trademarks


of AmerCable Incorporated
CIR

Ratings & Approvals


n 90C temperature rating
n UL listed as Type TC-ER (E123629)
n Flame Retardant IEEE 1202/FT-4
n Suitable for use in Class I, Div 2 and
Zone 2 environments
n UL listed as Marine Shipboard Cable
(E111461)
n Sunlight resistant
n Direct burial
www.nexansamercable.com e-mail: industrial@nexansamercable.com
15
37-102 CIRVFD 2000 Volts Crush & Impact Resistant
CIR VFD Stranding Profile
Closest Equivalent Uninsulated
Size Number IEEE 45 Metric Size Conductor
AWG/kcmil of Strands Std. Size (mm2) Dia. (inches)
14
12
10
8
6
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
646
777
19
19
37
37
61
133
133
209
266
342
418
532
646
777
925
1110
1332
1591
1924
4
6
10
16
26
41
66
83
106
133
168
212
262
313
373
444
535
646
777
2.08
3.29
5.23
7.57
12.49
21.11
33.51
42.79
54.45
70.01
85.57
108.91
132.25
159.06
189.36
227.23
272.68
325.70
393.87
0.074
0.093
0.113
0.136
0.175
0.258
0.324
0.361
0.407
0.461
0.510
0.575
0.654
0.720
0.785
0.860
0.941
1.029
1.132
*Cable diameters are subject to a +/- 5% manufacturing tolerance
NEC ampacities are based on Table 310.15 (B) (16) of the
National Electrical Code (NEC) for conductors rate 90C, in a
multi-conductor cable, at an ambient temperature of 30C.
The 75C column is provided for additional information. The
ampacities shown apply to open runs of cable, installation in
any approved raceway. Derating for more than three current
carrying conductors within the cable is in accordance with
NEC Table 310.15 (B) (3) (a). The ampacities shown also
apply to cables installed in cable tray in accordance with
NEC Section 392.80.
DC Resist. AC Resist. Inductive Voltage Drop Green
Size Nominal Weight @ 25C @ 90C, 60 Hz Reactance @ 90C Insulated IEEE NEC IEEE NEC
AWG/ Part No. Diameter (Lbs./ (Ohms/ (Ohms/ (Ohms/ (Volts/Amp/ Grounding Ampacity Ampacity Ampacity Ampacity
kcmil mm
2
37-102 Inches* 1000 Ft.) 1000 Ft.) 1000 Ft.) 1000 Ft.) 1000 Ft.) Size (AWG) 90C 90C 75C 75C
14 2.1 -508CIRVFD 0.768 297 2.907 3.635 0.040 5.073 18 24 15 20 15
12 3.3 -516CIRVFD 0.792 376 1.826 2.283 0.038 3.199 18 29 20 24 20
10 5.2 -308CIRVFD 0.888 492 1.153 1.441 0.036 2.032 14 38 30 32 30
8 7.6 -309CIRVFD 0.926 560 0.708 0.885 0.037 1.263 14 48 55 41 50
6 12.5 -310CIRVFD 1.051 826 0.445 0.556 0.033 0.804 12 65 75 54 65
4 21 -312CIRVFD 1.093 945 0.300 0.376 0.031 0.552 12 83 95 70 85
2 34 -314CIRVFD 1.225 1298 0.184 0.230 0.029 0.348 10 111 130 93 115
1 43 -315CIRVFD 1.341 1602 0.147 0.184 0.029 0.285 10 131 145 110 130
1/0 54 -316CIRVFD 1.447 1908 0.117 0.147 0.029 0.234 10 150 170 126 150
2/0 70 -317CIRVFD 1.566 2287 0.093 0.117 0.028 0.192 10 173 195 145 175
4/0 109 -319CIRVFD 1.874 3360 0.058 0.075 0.027 0.132 8 232 260 194 230
262 132 -320CIRVFD 2.093 4200 0.048 0.063 0.027 0.115 6 273 297 228 262
313 159 -321CIRVFD 2.130 4787 0.040 0.053 0.026 0.100 6 298 328 249 292
373 189 -322CIRVFD 2.257 5634 0.034 0.045 0.025 0.088 6 332 364 277 322
444 227 -323CIRVFD 2.400 6410 0.028 0.039 0.025 0.080 6 382 402 319 355
535 273 -324CIRVFD 2.705 7853 0.024 0.033 0.026 0.072 6 407 446 340 394
646 326 -326CIRVFD 2.898 9368 0.020 0.028 0.026 0.065 4 474 496 396 438
777 394 -327CIRVFD 3.102 11137 0.016 0.025 0.025 0.060 4 516 546 431 483
Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613
16
37-108VFD
Flexible TC-ER
VFD Power Cable
Three Conductor 90C 600V
Application
A flexible, shielded power cable specifically
engineered for use in variable frequency
AC motor drive (VFD) applications.
Features
n Specially engineered cable design produces a
longer cable life in VFD applications.
n Overall shield provides 100% coverage
containing VFD EMI emissions.
n Symmetrical ground conductors reduce induced
voltage imbalances and carry common mode
noise back to the drive.
n High strand count design is much more flexible,
easier to install and more resistant to vibration
than Type MC cable.
n Meets crush and impact requirements for
Type MC cable.
n AmerCables specially formulated insulation
material has a lower dielectric constant
(standard XLPE and EPR insulation materials
have higher dielectric constants) which
withstands reflected voltages. This allows for
longer output cable distances and minimizes
the effect of high frequency noise
induced into the plant ground system.
n Permitted for Exposed Run (ER)
use in accordance with the NEC.
n Permitted for use in Class I, Division 2 and Zone
2 industrial hazardous locations per the NEC.
n Gas and vapor tight impervious to water
and air.
n Reduced tray fill (up to 35% less)
than Type MC.
n Reduced installation time and cost compared
to Type MC.
n Glands for this product cost up to 50% LESS
than those for Type MC.
n Bend radius 12X O.D.
Insulation
Cross-linked, flexible, low
dielectric constant compound
rated 90C.
Sizes larger than 4/0 AWG
individual conductors
colored black with
conductor number surface
printed in contrasting ink.
Sizes 4/0 AWG and
smaller individually
colored conductors
red, white,black.
Jacket
Flame retardant, moisture
and sunlight resistant
Polyvinyl Chloride
(PVC). Colored black.
Power Conductors (x3)
Soft annealed flexible
stranded tinned copper
per ASTM B-33
Symmetrical Ground
Conductors (x3)
Three symmetrically
placed flexible
stranded tinned copper
conductors in direct
contact with the shield.
Metallic Shield
Sizes 8 AWG and
Larger Helically
applied 5 mil bare
copper tape.
Sizes Smaller than
8 AWG tin-coated
copper braid plus
aluminum/polyester
tape.
Both shielding systems
provide 100%
coverage.
TC-ER Ratings & Approvals
n UL Listed as Type TC-ER 600V
n UL Listed as 1000V flexible motor supply cable
(up to 4/0 AWG)
n 90C Temperature Rating
n FT-4 and IEEE 1202 flame ratings
n Sunlight resistant
n Direct burial
www.nexansamercable.com e-mail: industrial@nexansamercable.com
17
37-108 VFD Flexible TC-ER VFD 600 Volts
Cable diameters are subject to a +/- 5% manufacturing tolerance
Ampacity In Free Air: Based on 90C conductor temperature and 30C ambient
temperature per 2008 NEC Table B.310.3
Ampacity In Cable Tray: Based on 90C conductor temperature and 30C ambient
temperature per 2008 NEC Table 310.16
Ampacity In Conduit: Based on 90C conductor temperature and 30C ambient
temperature per 2008 NEC Table B.310.1
Size Size Number of Uninsulated Conductor
AWG/kcmil (mm2) Strands Diameter (inch)
14 2.08 19 0.074
12 3.29 19 0.093
10 5.23 37 0.113
8 8.30 133 0.159
6 13.21 133 0.201
4 21.17 259 0.255
2 35 259 0.321
1 42.52 259 0.361
1/0 50 266 0.413
2/0 66.12 323 0.455
4/0 95 532 0.584
262 120 646 0.654
313 150 777 0.720
373 185 925 0.785
444 240 1110 0.860
535 272.68 1332 0.941
646 300 1591 1.029
777 400 1924 1.132
Stranding Profile
DC AC Grounding
Nominal Resistance Resistance Inductive Voltage Drop Conductor
Size Size Part No. Diameter Weight at 25C 90C, 60Hz Reactance 90C, 60Hz (x3) In Free In Cable In
AWG/kcmil (mm2) 37-108 (inches) (lbs/1000ft) (ohms/1000ft) (ohms/1000ft) (ohms/1000ft) (Volts/Amp/1000ft) Size (AWG) Air Tray Conduit
14 2.08 -508VFD 0.466 158 2.907 3.635 0.036 5.069 18 15 15 15
12 3.29 -516VFD 0.509 199 1.826 2.283 0.034 3.195 16 20 20 20
10 5.23 -308VFD 0.522 258 1.153 1.441 0.032 2.028 14 30 30 30
8 8.30 -309VFD 0.653 368 0.708 0.885 0.036 1.262 14 65 55 48
6 13.21 -310VFD 0.737 517 0.445 0.556 0.034 0.804 12 87 75 65
4 21.17 -312VFD 0.956 814 0.300 0.376 0.031 0.552 12 114 95 89
2 35 -314VFD 1.103 1178 0.184 0.230 0.030 0.349 10 152 130 119
1 42.52 -315VFD 1.221 1462 0.147 0.184 0.031 0.287 10 177 150 137
1/0 50 -316VFD 1.447 1714 0.117 0.147 0.030 0.235 10 205 170 163
2/0 66.12 -317VFD 1.538 1951 0.093 0.117 0.029 0.193 10 237 195 186
4/0 95 -319VFD 1.883 3102 0.058 0.075 0.028 0.133 8 316 260 253
262 120 -320VFD 1.981 3642 0.048 0.063 0.026 0.114 6 362 297 286
313 150 -321VFD 2.082 4185 0.040 0.053 0.026 0.100 6 404 328 324
373 185 -322VFD 2.215 4834 0.034 0.045 0.025 0.088 6 449 364 357
444 240 -323VFD 2.371 5634 0.028 0.039 0.025 0.079 6 497 402 396
535 272.68 -324VFD 2.616 7592 0.024 0.033 0.025 0.071 6 556 446 441
646 300 -326VFD 2.878 9183 0.020 0.028 0.025 0.065 4 617 496 489
777 400 -327VFD 3.089 10834 0.016 0.025 0.025 0.060 4 688 546 537
Ampacity
Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613
18
37-105VFD
MMV-VFD
Power Cable
Three Conductor: 8kV - 15kV 133% Insulation Level Rated 90C
Applications
A flexible, braid and foil shielded,
power cable specifically engineered
for use in medium voltage variable
frequency AC drive (VFD) applications.
Features
n Flexible stranded conductors and
braided shields. Suitable for
applications involving repeated
flexing and high vibration.
n Small minimum bending radius
(8x OD) for easy installation.
n Insulation has a very low dielectric
constant. This allows for longer out-
put cable distances and
minimizes common mode current.
n Overall braid plus foil shield is
engineered with 100% coverage and a
surface transfer impedance <50 mil-
liohms at 10MHz to contain EMI.
n Symmetrical insulated ground
conductors reduce induced voltage
imbalances and carry common
mode noise back to the drive.
n High strand count conductors and
braid shield design is much more
flexible, easier to install and more
resistant to vibration than Type
MC cable.
n Severe cold durability: exceeds
CSA cold bend/cold impact
(-40C/-35C).
n Flame retardant: IEC 332-3
Category A and IEEE 1202.
n Suitable for use in Class I,
Division 1, and Zone 1
environments.
Low smoke
halogen-free
jacket available.
Contact your
AmerCable rep.
Conductors (3)
Soft annealed
flexible stranded
tinned copper per
IEEE 1580 Table 11.
Conductor Shield
A combination of semi-conducting tape and
extruded thermosetting semi-conducting material
meeting UL 1309, IEEE 1580 and UL1072.
Armor/EMI Shield
Overall tinned copper braid plus aluminum/
polyester tape provides 100% coverage.
This braid serves as both an armor and
EMI shield meeting both IEEE 1580 and
UL 1307/CSA 245.
Jacket
A black, arctic grade, flame retardant, oil,
abrasion, chemical and sunlight resistant
thermosetting compound meeting UL 1309/
CSA 245, IEEE 1580, and UL 1072. This
jacket allows for isolation between the
insulation shields and overall shield. Shields
can then be terminated on opposite ends to
minimize circulating currents.
Sheath (optional)
A black, arctic grade, flame retardant, oil,
abrasion, chemical and sunlight resistant
thermosetting compound meeting
UL 1309/CSA 245, IEEE 1580, and UL 1072.
Colored jackets for signifying different
voltage levels are also available on special
request (orange = 8kV and red = 15kV).
Insulation Shield
Composite shield
consisting of 0.0126"
tinned copper braided
with nylon providing
60% copper Shielded
coverage meeting
UL 1309, IEEE Std.
1580, and UL 1072.
The nylon is colored
for easy phase
identification (three
conductor = black,
blue, red) without
the need to remove
the shield to find
an underlying
colored tape.
Insulation Shield
Semi-conducting layer meeting UL 1309,
IEEE 1580 and UL 1072.
Insulation
Extruded thermosetting
90C Ethylene
Propylene Rubber
(EPR), meeting
UL 1309 (Type E),
IEEE 1580 (Type E)
and UL 1072.
Symmetrical Insulated
Grounding Conductors (3)
Soft annealed flexible stranded tinned copper
conductor per IEEE 1580 Table 11. Gexol
Insulation sized per Table 23.2 of UL1072.
Color: Green
Ratings & Approvals
n UL Listed as Marine Shipboard
Cable (E111461)
n American Bureau of Shipping (ABS)
n Det Norske Veritas (DNV) Pending
n Lloyds Register of Shipping (LRS)
Pending
n 90C Temperature Rating
n Voltage Rating 8kV to 15kV
(25kV available on request)
www.nexansamercable.com e-mail: industrial@nexansamercable.com
19
Three Conductor Type MMV-VFD Medium Voltage 8kV 133% Insulation Level
Three Conductor Type MMV-VFD Medium Voltage 15kV 133% Insulation Level
Cable diameters are subject to a +/- 5% manufacturing tolerance
Cable diameters are subject to a +/- 5%
manufacturing tolerance
Ampacity in Free Air: Based on 105C conductor
temperature and 40C ambient temperature per
2008 NEC Table 310.71
Ampacity in Conduit Air: Based on 105C conductor
temperature and 40C ambient temperature per
2008 NEC Table 310.75
Single Inductive Voltage Green Insulated
Size Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Drop Grounding
AWG/ Part No. Diameter (Lbs./ Air in Trays at 25C at 90C, 60Hz (ohms/ (Volts per amp Conductor (3x)
kcmil mm2 37-105 (inches) 1000 Ft.) (amps) (amps) (ohms/1000 Ft.) (ohms/1000 Ft.) 1000 Ft.) per 1000 Ft.) Size (AWG)
6
4
2
1
1/0
2/0
3/0
4/0
262
313
373
444
535
12.5
21
34
43
54
70
86
109
132
159
189
227
273
-332TSVFD
-333TSVFD
-334TSVFD
-335TSVFD
-336TSVFD
-337TSVFD
-338TSVFD
-339TSVFD
-340TSVFD
-341TSVFD
-342TSVFD
-343TSVFD
-344TSVFD
1634
2074
2625
3022
3373
3826
4411
5093
5993
6867
7810
8855
9905
1.687
1.868
2.071
2.161
2.262
2.381
2.489
2.631
3.857
3.030
3.164
3.319
3.492
88
116
152
175
201
232
266
306
348
386
429
455
528
75
99
129
149
171
197
226
260
296
328
365
387
449
0.445
0.300
0.184
0.147
0.117
0.093
0.074
0.058
0.048
0.040
0.034
0.028
0.024
0.556
0.376
0.230
0.184
0.147
0.117
0.094
0.075
0.063
0.053
0.045
0.039
0.033
0.048
0.043
0.040
0.038
0.037
0.036
0.035
0.033
0.032
0.032
0.031
0.030
0.030
0.820
0.564
0.359
0.294
0.242
0.199
0.166
0.139
0.121
0.106
0.094
0.085
0.076
10
10
10
8
8
8
6
6
6
6
4
4
4
Ampacity
Ampacity
Single Inductive Voltage Green Insulated
Size Nominal Weight In Free Banked DC Resistance AC Resistance Reactance Drop Grounding
AWG/ Part No. Diameter (Lbs./ Air in Trays at 25C at 90C, 60Hz (ohms/ (Volts per amp Conductor (3x)
kcmil mm2 37-105 (inches) 1000 Ft.) (amps) (amps) (ohms/1000 Ft.) (ohms/1000 Ft.) 1000 Ft.) per 1000 Ft.) Size (AWG)
2
1
1/0
2/0
3/0
4/0
262
313
373
444
34
43
54
70
86
109
132
159
189
227
-357TSVFD
-358TSVFD
-359TSVFD
-360TSVFD
-361TSVFD
-362TSVFD
-363TSVFD
-364TSVFD
-365TSVFD
-366TSVFD
3231
2959
4090
4615
5306
6131
7074
7787
8703
9912
2.403
2.468
2.596
2.714
2.875
3.028
3.260
3.363
3.500
3.652
156
178
205
234
269
309
352
389
432
456
133
151
174
199
229
263
299
331
367
388
0.184
0.147
0.117
0.093
0.074
0.058
0.048
0.040
0.034
0.028
0.230
0.184
0.147
0.117
0.094
0.075
0.063
0.053
0.045
0.039
0.0440
.0430
.041
0.0390
.038
0.037
0.035
0.034
0.034
0.033
0.364
0.299
0.246
0.203
0.170
0.142
0.124
0.109
0.097
0.080
10
8
8
8
6
6
6
6
4
4
37-449-5020PNAV
Enhanced THOF
Ship-to-Shore Power Cable 90C
600 Volts Flexible
Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613
20
Application
A flexible 600V cable used for ship-to-shore
power. Replaces former MIL-C 915 design
for most applications.
Features
n Complies with OPNAVINST 11310.3B
n Integral filled inner jacket for enhanced
toughness and crush resistance
n Water migration minimized
n Mold cured reinforced jacket for
enhanced abrasion and tear resistance
n Pigment colored jacketed singles for
phase identification
n Tinned copper conductors for
reduced corrosion
n Indent printed for long term identification
n Functional testing to ensure flexibility in
both summer and winter conditions
Separator
2 mil non-hygroscopic
opaque polyester
Jacket
Reinforced, flame retardant
extra heavy duty black
thermoset CPE specially
formulated to resist the
abrasive nature of the
application
Conductors
500 kcmil tin coated
copper. ASTM B-33,
ASTM B-172
Insulation
Type I EPR rated for 90C in
wet or dry locations.
Meets requirements of
UL 44 RHH, RHW-2
Color coded
white
red
black
Ratings & Approvals
n ICEA S 75-381: Portable and Power
Feeder Cables for Use in Mines and
Similar Applications
Enhanced THOF 37-449-502OPNAV 500 2.875 7563
Cable diameters and weights are
subject to +/- 5% manufacturing
tolerance
Consult factory for availability of
other conductor sizes
MIL-C 915 cable is also available.
Consult factory for details.
Approx.
Weight
lbs. per
1,000 ft. Product Part No.
Size
AWG/
kcmil
Nominal
Outside
Diameter
in.
www.nexansamercable.com e-mail: industrial@nexansamercable.com
21
37-449-5030PNAV
Enhanced PLUS THOF
Ship-to-Shore Power Cable 90C
600 Volts Flexible
Enhanced Plus THOF 37-449-503OPNAV 500 3.003 7854
Cable diameters and weights are subject to +/- 5% manufacturing tolerance
Consult factory for availability of other conductor sizes
MIL-C 915 cable is also available. Consult factory for details.
Approx.
Weight
lbs. per
1,000 ft. Product Part No.
Size
AWG/
kcmil
Nominal
Outside
Diameter
in.
Jacket
Extra-Heavy duty reinforced,
flame retardant black thermoset
CPE per ICEA S-75-381.
Specially formulated to resist
the abrasive nature of the
application.
Ratings & Approvals
n ICEA S-75-381: Portable and Power Feeder
Cables for Use in Mines and Similar
Applications
Application
A tough flexible 3/C 600V ungrounded
power cable specifically designed for naval
shore-to-ship and other pier side power
applications. Enhanced Plus THOF is
specially designed for additional sunlight
and weather resistance.
Features
n Complies with OPNAVINST 11310.3B
n Integral filled inner jacket for enhanced
toughness and crush resistance
n Water migration minimized
n Mold cured reinforced jacket for
enhanced abrasion and tear resistance
n Jacketed singles (Enhanced Plus) for
increased resistance to sunlight and
weather
n Pigment colored jacketed singles for
phase identification
n Tinned copper conductors for
reduced corrosion
n Indent printed for long term identification
n Functional testing to ensure flexibility in
both summer and winter conditions
Conductor
Jacket
Enhanced Plus Only.
CPE Composite
meets requirements
of UL 44 RHH,
RHW-2. Pigment
colored red,
white and black.
Conductor
Insulation
EPR per ICEA S-75-381
Meets requirements of
UL 44 RHH, RHW-2
Conductor
Class I, 500 kcmil tin
coated copper.
ASTM B-33, ASTM B-172
37-003
Flexible Grounding Cable
Clear Yellow Other Colors
Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613
22
Application
Flexible jacketed cable used for
grounding jumpers installed
temporarily for protective grounding
of de-energized circuits.
Features
n Transparent jacket provides easy
confirmation of continuity and
ease of trouble shooting
n Extremely flexible stranding for
ease of bending and installation
n Transparent thermoplastic jacket
for installation and flexible use
at temperatures ranging
from -25C to 90C
n Jacket material meets Type II
requirements of ASTM F-855
n Jacket material meeting Type I
(-50C) requirements of ASTM
F-855 available upon request
Ratings & Approvals
n ASTM B-3: Standard Specification
for Soft or Annealed Copper Wire
n ASTM F-855: Standard
Specifications for Temporary
Protective Grounds to Be Used
on De-energized Electric
Power Lines and Equipment
Identification
A marker tape printed
AMERCABLE-SIZE-
GROUNDING CABLE
is readily visible under
the transparent jacket.
Jacket
Transparent thermoplastic
for ease of installation and
flexible use at temperatures
ranging from -25C to 90C.
This material meets Type II
requirements of ASTM F 855.
Material meeting a -50C
cold bend is available on
a special order basis.
Conductor
Bunched strands of bare
copper annealed dead soft
in accordance with ASTM
B-3. Other strand is
available upon request.
002 2 665 0.100 0.530 293
010 1/0 1050 0.100 0.650 458
020 2/0 1323 0.105 0.700 557
040 4/0 2107 0.110 0.850 857
Cable diameters and weights are subject to
+/- 5% manufacturing tolerance
Approx.
Weight
lbs. per
1,000 ft.
Part No.
37-003-
Size
AWG/
kcmil
Minimum
Wires per
Conductor
Nominal
Jacket
Thickness
in.
Nominal
Outside
Diameter
in.
Order Your Grounding Cables with
Factory Installed
Connectors
SAVE
TIME
SAVE
MONEY
Other ground jacketing materials
and colors available.
Consult factory for details.
www.nexansamercable.com e-mail: industrial@nexansamercable.com
23
37-409
Lead Covered Grounding Cable
Application
A grounding conductor for use in power
distribution systems where a lead sheath
is required over the copper conductor
to provide additional protection
against corrosion. Also suitable for use
in lightening protection applications.
Features
n Lead sheath offers rugged,
durable construction
Ratings & Approvals
n ASTM B-3: Standard Specification for
Soft or Annealed Copper Wire
n ASTM B-8: Standard Specification
for Concentric-Lay-Stranded Copper
Conductors, Hard, Medium-Hard
or Soft
Conductor
Uncoated annealed copper
meeting the requirements
of ASTM B-3
Lead Sheath
An extruded layer of
lead for enhanced
performance
004 4 7 0.045 0.319 366
005 2 7 0.045 0.377 508
366 1/0 19 0.065 0.497 836
020 2/0 19 0.065 0.542 984
360 3/0 19 0.065 0.600 1202
615 4/0 19 0.065 0.648 1420
250 250 37 0.065 0.694 1528
351 350 37 0.065 0.797 1985
147 400 37 0.065 0.842 2478
361 500 37 0.065 0.931 2684
Cable diameters and weights are subject to +/- 5% manufacturing tolerance
Approx.
Weight
lbs. per
1,000 ft.
Part No.
37-409-
Size
AWG/
kcmil
Minimum
Wires per
Conductor
Nominal
Lead Sheath
Thickness
in.
Nominal
Outside
Diameter
in.
37-221
Red Jumper Cable
Flexible 5000/15000 Volts 90C
Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613
24
Application
Portable dual rated 5000/15000 volt jumper
cables can be used as temporary jumper
leads for portable or mobile substations,
or for temporarily by-passing damaged or
faulted sections of power cable. The finely
stranded conductor provides an exceptionally
flexible cable that can be easily trained
and connected in confined areas such as
transformer vaults and switch gear
enclosures.
Features
n Extremely flexible stranding
n Bright red thermosetting jacket
n The conductor shield is bonded
to the insulation providing easy,
clean stripping
n The 90C insulation has excellent
dielectric properties and is highly
resistant to heat, moisture
and ozone.
Insulation
Heat resisting 90C
Ethylene-Propylene rubber
(EPR), meeting ASTM
D-2802. It has excellent
dielectric properties and is
highly resistant to heat,
moisture, and ozone.
Jacket
Thermosetting bright red
jacket, 90C rated
Conductors
Flexible-stranded, tinned,
annealed coated copper per
ASTM B-33
Ratings & Approvals
n ASTM B-33: Standard Specification for Tinned Soft or
Annealed Copper Wire for Electrical Purposes
n ASTM D2802: Standard Specification for Ozone-
Resistant Ethylene-Alkene Polymer Insulation for Wire
and Cable
Conductor Shield
Combination semiconducting
tape and/or extruded
semiconductive thermosetting
material. The semiconductive
tape prevents any penetration
of the extruded conductor
shield into the inner layers
of the flexible conductor.
Identification
Cable is surface printed
showing manufacturers
name, size, voltage rating,
and temperature rating
Application Note
Jumper cables should NOT be used in place of normal high voltage cables. They should
be isolated in areas where contact with people is limited. Because jumper cables cannot be
protected against prolonged contact with other conductors or grounds by shielding, these
cables must be positioned away from contact with grounds, transformer cases, cross-arms,
etc., to avoid possible high stress and capacitance leakage. Cables should be installed with at
least one cable diameter of separation between adjacent conductors and between conductors
and all metallic and/or electrically grounded parts. These cables are not intended for
permanent service.
www.nexansamercable.com e-mail: industrial@nexansamercable.com
25
37-221 Red Jumper Cable 5000/15000 Volts
008 8 133 0.210 0.065 0.777 310 83/NA*
006 6 133 0.210 0.065 0.816 360 110/110
004 4 259 0.210 0.065 0.875 449 145/150
003 3 259 0.210 0.065 0.903 495 170/170
002 2 259 0.210 0.065 0.944 563 190/195
001 1 259 0.210 0.065 0.981 635 225/225
010 1/0 266 0.210 0.065 1.040 742 260/260
020 2/0 323 0.210 0.065 1.090 869 300/300
030 3/0 418 0.210 0.065 1.133 976 345/345
040 4/0 532 0.210 0.065 1.215 1181 400/400
250 250 627 0.210 0.065 1.216 1281 445/445
350 350 888 0.210 0.065 1.327 1692 550/550
500 500 1221 0.210 0.065 1.456 2192 695/685
8 AWG Jumper recommended only for use at 5kv
Cable diameters and weights are subject to +/- 5% manufacturing tolerance
Ampacity is calculated with a 90C conductor temperature and 40C ambient air,
per 2008 NEC, Table 310.69
Approx.
Weight
lbs. per
1,000 ft.
Ampacity
90C
at 5kV/15 kV
Part No.
37-221-
Size
AWG/
kcmil
Minimum
Wires per
Conductor
Nominal
Insulation
Thickness
in.
Nominal
Jacket
Thickness
in.
Nominal
Outside
Diameter
in.
Order Your Red Jumper Cable with
Factory Installed
Connectors
SAVE
TIME
SAVE
MONEY
37-550
Mobile Substation Power Cable Type SH
Single Conductor 5000 to 35000 Volts 90C
Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613
26
Application
These single conductor portable power
cables are extremely flexible and specifically
designed for use on mobile substation
equipment. The Type SH cable is often
necessary for supplying power while
replacing damaged utility poles or during
routine maintenance of substations.
Features
n Extremely flexible stranding for ease
of bending
n The conductor shield is bonded to the
insulation providing easy, clean
stripping
n Jacket is heat, oil, flame and
chemical resistant
n Continuous conductor
temperature 90C
n Jackets available in voltage colors,
yellow (5 & 8kV), orange (15kV),
red (25 & 35kV). Consult factory
for availability of other colors.
Ratings & Approvals
n ASTM B-33: Standard
Specification for Tinned
Soft or Annealed
Copper Wire for
Electrical Purposes
n ICEA S-75-381/NEMA WC-58:
Portable and Power Feeder
Cables for Use in Mines and
Similar Applications
n UL 1072 Medium Voltage
Cable MV-105 (pending)
Conductor Shield
Combination semi-conducting
tape and/or extruded
semiconductive thermosetting
material
Jacket
CPE meeting ICEA
S-75-381/NEMA WC58.
Consult factory for
availability of other
jacket materials.
Conductor
Flexible tin-coated soft
annealed bunch stranded
copper meeting ASTM B-33
Identification
Cable shall be surface
printed showing manufacturer,
size, voltage rating, type and
temperature rating
Insulation
Heat, moisture and ozone
resisting 90C Ethylene-
Propylene rubber (EPR)
meeting ICEA S-75-
381/NEMA WC58
Insulation Shield
Tin-coated copper braid
applied over a
semiconductive tape
(5-15kV). Extruded
semi-conductive
thermosetting material
(25-35kV)
CSA approval
available by
special order
www.nexansamercable.com e-mail: industrial@nexansamercable.com
27
5kV Single Conductor Portable Power Cable Type SH
Cable diameters and weights are subject to +/- 5% manufacturing tolerance
Ampacity is calculated with a 90C conductor temperature
and 40C ambient air, per 2008 NEC, Table 310.69
002 2 259 .110 .125 0.975 674 190
004 1/0 266 .110 .140 1.058 825 260
005 2/0 323 .110 .140 1.170 1039 300
007 4/0 532 .110 .155 1.300 1393 400
008 250 627 .120 .155 1.330 1477 445
022 350 888 .120 .170 1.484 1926 550
010 500 1221 .120 .190 1.700 2662 695
Approx.
Weight
lbs. per
1,000 ft.
Ampacity
90C
Part No.
37-550-
Size
AWG/
kcmil
Minimum
Wires per
Conductor
Nominal
Insulation
Thickness
in.
Nominal
Jacket
Thickness
in.
Nominal
Outside
Diameter
in.
016 2 259 .210 .155 1.203 881 195
017 1/0 266 .210 .155 1.320 1147 260
018 2/0 323 .210 .155 1.350 1226 300
020 4/0 532 .210 .170 1.497 1594 400
021 250 627 .210 .170 1.547 1758 445
009 350 888 .210 .190 1.765 2364 550
024 500 1221 .210 .190 1.900 2937 685
15kV Single Conductor Portable Power Cable Type SH
Approx.
Weight
lbs. per
1,000 ft.
Ampacity
90C
Part No.
37-550-
Size
AWG/
kcmil
Minimum
Wires per
Conductor
Nominal
Insulation
Thickness
in.
Nominal
Jacket
Thickness
in.
Nominal
Outside
Diameter
in.
030 1/0 266 .295 .170 1.500 1350 260
031 2/0 323 .295 .170 1.555 1507 300
033 4/0 532 .295 .190 1.713 1909 395
034 250 627 .295 .190 1.763 2085 440
035 350 888 .295 .190 1.886 2517 545
037 500 1221 .295 .205 2.048 3168 680
25kV Single Conductor Portable Power Cable Type SH
Approx.
Weight
lbs. per
1,000 ft.
Ampacity
90C
Part No.
37-550-
Size
AWG/
kcmil
Minimum
Wires per
Conductor
Nominal
Insulation
Thickness
in.
Nominal
Jacket
Thickness
in.
Nominal
Outside
Diameter
in.
050 1/0 266 .380 .170 1.175 1632 260
051 2/0 342 .380 .205 1.840 1898 300
053 4/0 532 .380 .205 1.915 2235 395
054 250 627 .380 .205 1.975 2509 440
055 350 888 .380 .205 2.100 2901 545
057 500 1221 .380 .205 2.280 3396 680
35kV Single Conductor Portable Power Cable Type SH
Approx.
Weight
lbs. per
1,000 ft.
Ampacity
90C
Part No.
37-550-
Size
AWG/
kcmil
Minimum
Wires per
Conductor
Nominal
Insulation
Thickness
in.
Nominal
Jacket
Thickness
in.
Nominal
Outside
Diameter
in.
Order Your
Type SH
Cables
Connectorized!
Factory installed
assemblies
from AmerCable help
lower your overall
connectivity costs.
n Lugs
n Elbows
n Stress Cones
Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613
1
Factory Installed
Cable Assemblies
n Lugs
n Elbows
n Stress Cones
Factory Installed Cable Assemblies from Nexans AmerCable are
professionally assembled in our El Dorado, Arkansas manufacturing
facility. Our team of experienced handlers join cables and connectors that
match your exact application spec. Our assemblies are designed, built
and tested to perform upon arrival in your harshest operating conditions.
Factory prepared cable assemblies are a reliable way to lower your
overall cable connectivity costs through enhanced reliability, reduced
handling and lower installation time.
Save money through
reduced prep, handling
and installation time.
28
www.nexansamercable.com e-mail: industrial@nexansamercable.com
Renewable Energy
Cables
29
Nexans AmerCable is the leading producer of renewable energy cables in North America.
Contact your Nexans AmerCable rep for a copy of our Renewable Energy Cables catalog.
Wind Power
Cables
Type MMV-WP
1/C and 3/C
5kV, 15kV and 35kV
Rated 105C
Medium Voltage Wind
Turbine Service Loops
DLO
2000 Volts
90C
Low Smoke
(sizes 2/0 & higher)
EP/CPE
RHH, RHW-2
Nexans AmerCables AmerSol is the first
U.S. manufactured solar cable to achieve
TV and UL certification. This versatile
single-conductor cable is designed to meet
the varying needs of the Solar Industry.
Applications include connection to module
junction boxes; required cable routing in
balance of system (BOS) integration.
Rated 600V UL and 1000V TV.
Wind Applications
email: greencables@nexansamercable.com
Phone: 800-506-9473
713-896-5800
Solar Applications
email: solarcables@nexansamercable.com
Phone: 800-643-1516
870-862-4919
Solar Power Cables
Also available:
Type PV UL4703 (2000V) and
Type TC Multiconducutor (2000V)
Nexans AmerCable manufactures high quality
jacketed electrical cables for a wide variety of specialized
industrial and utility applications.
Nexans AmerCable is an ISO 9001 certified
cable manufacturer that combines leading-
edge technology, proven manufacturing
techniques, and high quality service
to deliver the finest industrial and utility
cable products available.
Nexans AmerCable serves a worldwide customer base
from our manufacturing facility in El Dorado, Arkansas.
Our professional field engineering and sales force work
directly with customers, or in partnership with our
network of independent distributors, to identify
and fulfill your specific cable requirements.
What can you expect from Nexans AmerCable?
n High Quality Cable
n On-Time Delivery*
n Professional Sales, Support
and Service
n Strategic Inventory Locations
n Operational Excellence
n Short Lead Times
Nexans AmerCables manufacturing facility and
corporate headquarters in El Dorado, Arkansas.
350 Bailey Road El Dorado, Arkansas USA
(870) 862-4919 (800) 643-1516 Fax (870) 862-9613
e-mail: industrial@nexansamercable.com www.nexansamercable.com
8_13 2013, AmerCable Incorporated
Made in America
* Check www.nexansamercable.com
for our most current on
time delivery record
For complete product information: www.nexansamercable.com
Industrial Cables Industrial Cables

Das könnte Ihnen auch gefallen