Sie sind auf Seite 1von 45

VITA

PO Box 19658, Fountain Hills, AZ 85269


PH: 480-837-7486
Email: info@vita.com
URL: http://www.vita.com
Approved American National Standard
ANSI/VITA 60.0
Alternative Connector for VPX
Abstract
This standard, VITA 60.0 Alternative Connector for VPX, provides an alternate connector
to the one specified in the VITA 46.0 VPX Baseline Standard. Because the 46.0 and the
60.0 connectors are not intermateable, a VITA 60.0 module will not plug into a VITA
46.0.0 backplane and vice versa. However, the VITA 60.0 standard provides VPX users
with the flexibility to choose a VPX module and backplane connector combination for their
specific application requirements.


Approved February 2012
American National Standards Institute, Inc.





American
National
Standard
Approval of an American National Standard requires verification by
ANSI that the requirements for due process, consensus, and other criteria
for approval have been met by the standards developer.

Consensus is established when, in the judgment of the ANSI Board of
Standards Review, substantial agreement has been reached by directly
and materially affected interests. Substantial agreement means much
more than a simple majority, but not necessarily unanimity. Consensus
requires that all views and objections be considered, and that a concerted
effort be made toward their resolution.

The use of American National Standards is completely voluntary; their
existence does not in any respect preclude anyone, whether he has
approved the standards or not, from manufacturing, marketing,
purchasing, or using products, processes, or procedures not conforming
to the standards.
The American National Standards Institute does not develop standards
and will in no circumstances give an interpretation of any American
National Standard. Moreover, no person shall have the right or authority
to issue an interpretation of an American National Standard in the name
of the American National Standard Institute. Requests for interpretations
should be addressed to the secretariat or sponsor whose name appears on
the title page of this standard.

CAUTION NOTICE: This American National Standard may be revised
or withdrawn at any time. The procedures of the American National
Standards Institute require that action be taken periodically to reaffirm,
revise, or withdraw this standard. Purchases of American National
Standards may receive current information on all standard by calling or
writing the American National Standards Institute.


NOTE The users attention is called to the possibility that compliance with this standard may require use
of an invention covered by patent rights.

By publication of this standard, no position is taken with respect to the validity of this claim or of any patent
rights in connection therewith. The patent holder has, however, filed a statement of willingness to grant a
license under these rights on reasonable and nondiscriminatory terms and conditions to applicants desiring to
obtain such a license. Details may be obtained from the standards developer.
Published by

VMEbus International Trade Association (VITA)
PO Box 19658, Fountain Hills, AZ 85269
Copyright 2012 by VMEbus International Trade Association

All rights reserved.

Permission of the publisher is required to reproduce this document or any part of it.
Printed in the United States of America - R1.0
ISBN 1-885731-69-8

3

Table of Contents
1 INTRODUCTION ............................................................................................................. 8
1.1 Objectives ............................................................................................................................................... 8
1.2 VITA 60.0 Overview ................................................................................................................................ 8
1.3 Terminology ............................................................................................................................................ 9
1.3.1 Specification Key Words ..................................................................................................................................... 9
1.3.2 VITA 60.0 Definitions ....................................................................................................................................... 10
1.4 References ............................................................................................................................................ 11
2 VITA 60.0 COMPLIANCE ............................................................................................. 13
3 SYSTEM ........................................................................................................................ 13
4 COMMON REQUIREMENTS ........................................................................................ 13
4.1 Overview ............................................................................................................................................... 13
4.2 Connectors ............................................................................................................................................ 13
4.3 Form Factor and Outline ....................................................................................................................... 16
4.4 Alignment and Keying ........................................................................................................................... 16
4.4.1 Background and Assumptions ........................................................................................................................... 16
4.4.2 Definitions .......................................................................................................................................................... 19
4.4.3 Keying Rules ...................................................................................................................................................... 19
4.5 Two Level Maintenance ........................................................................................................................ 20
4.6 Connector Pin Definition P0 ............................................................................................................... 20
4.7 Electrical Budgets for Protocol Standards ............................................................................................ 20
4.8 Signal Definition P0 ........................................................................................................................... 20
4.8.1 Power ................................................................................................................................................................. 20
4.9 Connector Pin Definition - P1 ............................................................................................................... 21
5 3U MODULE ................................................................................................................. 22
5.1 Overview 3U Module ......................................................................................................................... 22
5.2 Connectors 3U Module ...................................................................................................................... 22
5.3 Keying 3U Module ............................................................................................................................. 22
5.4 Connector Pin Definition 3U Module P2 ............................................................................................ 22
5.4.1 Standard Connector P2 ...................................................................................................................................... 22
5.4.2 Recommended Location on 3U module for Application-Specific Connector ................................................... 22
6 MODULE ....................................................................................................................... 23
6.1 Overview ............................................................................................................................................... 23
6.2 Connectors ............................................................................................................................................ 23
6.3 Alignment and Keying ........................................................................................................................... 25
6.4 Connector Pin Definition ....................................................................................................................... 25
6.4.1 Connector P2 ...................................................................................................................................................... 25
6.4.2 Connector P3 ...................................................................................................................................................... 25
6.4.3 Connector P4 ...................................................................................................................................................... 26
6.4.4 Connector P5 ...................................................................................................................................................... 26
6.4.5 Connector P6 ...................................................................................................................................................... 26
6.4.6 Locations on 6U module for User Defined Application-Specific Connectors .................................................. 27
7 BACKPLANES ............................................................................................................. 27

4

7.1.3 Connector Selection ........................................................................................................................................... 27
7.8 Backplane Keying ................................................................................................................................. 29
7.9 Preventing Damage from Backwards Plug-in Module Insertion ........................................................... 29
List of Figures
FIGURE 4-1: VITA 60.0 CONNECTOR IDENTIFICATION FOR 3U AND 6U MODULES ............................... 14
FIGURE 4-2: CONNECTOR IDENTIFICATION FOR 3U AND 6U MODULES .................................................. 15
FIGURE A-1 3U AIR COOLED MODULE LAYOUT .................................................................................... 30
FIGURE A-2 3U CONDUCTION COOLED LAYOUT ................................................................................... 31
FIGURE A-3 6U AIR COOLED LAYOUT ................................................................................................... 32
FIGURE A-4 6U CONDUCTION COOLED LAYOUT ................................................................................... 33
FIGURE A-5 3U CONDUCTION COOLED MODULE END VIEW ................................................................. 34
FIGURE A-6 6U CONDUCTION COOLED MODULE END VIEW ................................................................. 35
FIGURE A-7 3U CHASSIS SIDE WALL ..................................................................................................... 36
FIGURE A-8 CONDUCTION COOLED MODULE SIDE VIEW ...................................................................... 37
FIGURE B-1 3U AIR COOLED BACKPLANE ............................................................................................. 38
FIGURE B-2 6U AIR COOLED BACKPLANE ............................................................................................. 39
FIGURE B-3 3U CONDUCTION COOLED BACKPLANE, PLAN VIEW ......................................................... 40
FIGURE B-4 6U CONDUCTION COOLED BACKPLANE, PLAN VIEW ......................................................... 41
FIGURE B-5 6U BACKPLANE, END VIEW ............................................................................................... 42
FIGURE C-1 3U PCB FABRICATION DRAWING (VIEWED FROM PRIMARY SIDE) ..................................... 44
FIGURE C-2 6U PCB FABRICATION DRAWING (VIEWED FROM PRIMARY SIDE) ..................................... 45
LIST OF TABLES
TABLE 4-1: POWER WAFER CURRENT RATINGS .................................................................................... 21
TABLE 5-1: 3U VITA 60.0 3U MODULE CONNECTORS .......................................................................... 22
TABLE 6-1: 6U VITA 60.0 3U MODULE CONNECTORS .......................................................................... 24
TABLE 7-1: BACKPLANE CONNECTOR CROSS-REFERENCE ..................................................................... 28

5

Abstract
This standard, VITA 60.0 Alternate Connector for VPX, provides an alternative connector to the one
specified in the VITA 46.0 VPX Baseline Standard. Because the 46.0 and the 60.0 connectors are not
intermateable, a VITA 60.0 module will not plug into a VITA 46.0.0 backplane and vice versa.
However, the VITA 60.0 standard provides VPX users with the flexibility to choose a VPX module
and backplane connector combination for their specific application requirements
Foreword
VME has been the de-facto bus standard for Commercial off the Shelf (COTS ) Circuit Card
Assemblies since the 1980s. VME boards have proven to be remarkably capable of evolving to
support newer technologies with innovations such as VME Subsystem Bus, PCI Mezzanine Cards
(PMCs) and VME320.
However, advances in technologies, particularly in interconnects, have demonstrated the need for an
advance in system development. This advance needs to accommodate high speed interconnect,
particularly serial interconnects, and higher power delivery in concert with better heat removal.
This standard addresses these needs in the context of IEEE 1101 form factor modules. Other
specifications may address alternate outlines, such as VITA-48.
Because electronics miniaturization is driving the plug-in module I/O count, most system
interconnects will need:
! Multi-gigabit differential technology
! Core computing cluster switched fabrics
! Serial RapidIO, PCI Express, Hypertransport, Inifiniband or 10G Ethernet
! Sufficient ports to enable distributed switching or centralized switching
The plethora of high-speed interfaces available for tomorrows plug-in modules include:
! Network interfaces
! Digital video
! Mass storage interface
! FPGA-based inter-board connections
! Custom sensor interfaces
VITA 60.0 provides an intermountable alternate to the VITA 46.0 connector for VME users:
! To leverage the broad spectrum of high-speed interconnect technologies
! Backward compatibility with VME bus electrical, software and selected mechanicals
! Enables heterogeneous architectures which preserve existing investments in COTS-based
systems
! Addresses both 3U and 6U form factors
! Harsh environment fit designed-in up front in the standard
! Rugged air or conduction-cooled form factors
! High value placed on rear-panel I/O
! High-speed connector survivability/compliance

6

! Connector with ESD protection and options for handling covers to accommodate 2-level
maintenance.
! Space constrained high compute density applications
Other Defense and Aerospace market needs are also under consideration. Standards Innovation is the
COTS Industrys Most Compelling Value Proposition.
Working Group Members
The Working Group members as listed on the sign-up sheet from the 18 Nov 2008 meeting including
additional contributing members since that date.
NAME COMPANY
Andrew Shieh CSP, Inc.
Andrew Stringer Lockheed Martin Corporation
Ben Jeffrey Molex
Bill Hanna Boeing
Bill Northey FCI Electronics
Bob Patterson Tyco Electronics
Bob Sullivan Curtiss-Wright Controls Electronic Systems
Bruce Thomas Curtiss Wright
Chad Siemering Rockwell Collins
Dan Golden Boeing
Dan Toohey Mercury Computer
David Dix Amphenol
David Pepper GE Embedded Systems
Dean Holman Mercury Computer
Earle Olson Tyco Electronics
Ed Garstkiewicz Harting Inc. of North America
Fred Fons Foxconn
Frank Hom APW Electronic Solutions
Gerard Drewek General Dynamics
Gerry Marino Lytron Inc.
Greg Powers Tyco Electronics
Greg Rocco Mercury
Ivan Straznicky Curtiss-Wright Controls Embedded
Jaret Paul Amphenol
Jim Goldenberg GE-IP
Jim Reedy DRS-SS
Jim Vana 3M
Joe Brokesh Curtiss-Wright
John Rynearson VITA
Lori Bechtold Boeing
Mac Rush Emerson
Melissa Heckman Bustronic Corporation
Michael Biemer Northop Grumman
Michael Munroe Bustronics
Michael Thompson Pentair Electronic Packaging
Michele York Amphenol
Mike Gust Mercury Computer
Mike Hasenfratz Northrop Grumman
Pat Shaw GD Canada
Paul Griffith Concurrent Technologies
Pete Jha Curtiss Wright
Rex Harvey Parker

7

NAME COMPANY
Richard Hodges Parker
Rick Stevens LMCO
Robert Ford Boeing
Ronald Schoomaker Lockheed Martin
Scott Goedeke Northrop Grumman
Stephen Cecil NAVSEA Crane Division
Steve Lawler EPT
Steve Konsowski Northrop Grumman
Steve Birch TEK Microsystems
Terry Dilling General Dynamics
Vince Luca Amphenol
Wolfgang Schmidt EPT
Comments, Corrections and/or Additions
Anyone wishing to provide comments, corrections and/or additions to this standard, please direct
them to the VITA technical director at techdir@vita.com, www.vita.com.
VSO and Other Standards
Should anyone want information on other standards being developed by the VSO, VME Product
Directories, VME Handbooks, or general information on the embedded systems market, please
contact the VITA office at the address or telephone number given on the front cover.


8

1 Introduction
VITA 60.0 provides an alternative connector to the one specified in VITA 46.0, VPX Baseline
Standard. Because the 46.0 and the 60.0 connectors are not intermateable a VITA 60.0 module will
not plug into a VITA 46.0 backplane and vice versa. However, the VITA 60.0 standard provides
VPX users with the flexibility to choose a VPX module and backplane connector combination for
their specific application requirements.
This document provides a standard mechanical format for standardization of switched serial
interconnects for VMEbus applications, with specific concern taken to allow deployment in
ruggedized environments. There are many candidate technologies for switched serial interconnects.
These include without limitation: Ethernet through 10 GBit, Fibre Channel, InfiniBand, Serial
RapidIO, PCI Express, Hypertransport, Infiniband and others. Each technology has its pros and
cons, and the market will determine which ones will ultimately survive. The data plane proposed
defines a playing field on which users may implement their preferred serial interconnect.
1.1 Objectives
The objectives of this standard are:
! Define a 6U and 3U Eurocard format family of plug-in modules suitable for ruggedized use
utilizing the VITA 60.0 interconnects.
! Define a scalable high-speed connector that can bridge from < 1 Gbps up to 10 Gbps data
rates.
! Maintain current VITA 46.0 mechanical standardization format for referenced switched serial
interconnect technologies.
! Make provision for additional I/O capability at the plug-in module level including RF and
Optical interconnects.
! Maintain current VITA 46.0 option of two level maintenance capable Line Replaceable
Modules.
1.2 VITA 60.0 Overview
The VITA 60.0 standard is a supplement to the VITA 46.0 family of standards outlining only the
areas of dissimilarity to the base standard. Alternate Connector for VPX is the name given to this
standard.
For reference purposes, at the time of publication the following protocol standards had been
defined. Please consult VITA for a current list. VITA 46.0
The VITA 60.0 base standard includes features drawn from IEEE 1101.1 and IEEE 1101.2 (for air
cooled and conduction cooled plug-in modules, respectively). These features are evident in the
mechanical drawings provided.
The VITA 60.0 base standard defines physical features that enable high-speed communication in a
compliant system. These features include: a 6U by 160mm by 4HP pitch Eurocard format board with

9

high speed differential connectors, a 6U by 160mm by 4HP pitch Eurocard format board with a
combination of high speed differential and single-ended connectors, and the backplane/chassis
infrastructure needed to support these features. The base standard also defines similar physical
features for 3U by 160mm by 4HP pitch Eurocard format, providing the same two types of connector
options discussed above for 6U plug-in modules. Many features called for in the base specification
will be compatible with the requirements of other standards, such as VITA-48, but this standard
concerns only the IEEE 1101 compatible applications.
This base standard also defines alignment and keying features used to protect the connector system.
The base standard does not address the possible serial fabric configurations available in systems
which utilize the standard.
While the base standard does not address the use of ANSI/VITA-1.1 or VITA-41 plug-in modules, or
modules which are constructed to the mechanical requirements of VITA-48, chassis and backplanes
can be constructed which provide compatibility with plug-in modules built to these standards. The dot
specifications allow the use of the single-ended connector allocation for parallel busses, such as VME
or PCI, completing the compatibility between older standards and this one.
1.3 Terminology
1.3.1 Specification Key Words
To avoid confusion and to make very clear what the requirements for compliance are, many of the
paragraphs in this standard are labeled with keywords that indicate the type of information they
contain. These keywords are listed below:
! Rule
! Recommendation
! Suggestion
! Permission
! Observation
Any text not labeled with one of these keywords should be interpreted as descriptive in nature. These
will be written in either a descriptive or a narrative style.
The keywords are used as follows:

10

Rule <chapter>-<number>:
Rules form the basic framework of this standard. They are sometimes expressed in text form and
sometimes in the form of figures, tables or drawings. All rules shall be followed to ensure
compatibility between board and backplane designs. All rules use the shall or shall not words to
emphasize the importance of the rule. The shall or shall not words are reserved exclusively for
stating rules in this standard and are not used for any other purpose.
Recommendation <chapter>-<number>:
Wherever a recommendation appears, designers would be wise to take the advice given. Doing
otherwise might result in poor performance or awkward problems. Recommendations found in this
standard are based on experience and are provided to designers to speed their traversal of the learning
curve. All recommendations use the should or should not words to emphasize the importance of
the recommendation. The should or should not words are reserved exclusively for stating
recommendations in this standard and are not used for any other purpose.
Suggestion <chapter>-<number>:
A suggestion contains advice, which is helpful but not vital. The reader is encouraged to consider the
advice before discarding it. Some design decisions that need to be made are difficult until experience
has been gained. Suggestions are included to help a designer who has not yet gained this experience.
Permission <chapter>-<number>:
In some cases a rule does not specifically prohibit a certain design approach, but the reader might be
left wondering whether that approach might violate the spirit of the rule or whether it might lead to
some subtle problem. Permissions reassure the reader that a certain approach is acceptable and will
cause no problems. All permissions use the may words to emphasize the importance of the
permission. The lower-case may words are reserved exclusively for stating permissions in this
standard and are not used for any other purpose.
Observation <chapter>-<number>:
Observations do not offer any specific advice. They usually follow naturally from what has just been
discussed. They spell out the implications of certain rules and bring attention to things that might
otherwise be overlooked. They also give the rationale behind certain rules so that the reader
understands why the rule must be followed.
1.3.2 VITA 60.0 Definitions
The following terms are used within the body of the specification. In this context, they have the
following meanings:
Term Definition
2-level maintenance (Two
Level Maintenance)
A maintenance system where plug in modules are the field
replaceable units; a subset of whose requirements are that

11

Term Definition
the module provides both mechanical and ESD protection.
Air cooled A plug-in module which is intended to have heat removed
by transfer to an air stream flowing over the module
Chassis Ground See Safety Ground.
Conduction cooled a plug-in module which is intended to have heat removed
by transfer to the chassis through mechanical contact with a
chassis component
Differential Wafer A wafer designed for the connection of high speed
differential pairs (up to 10 Gbps), each of which has a
minimum of 2 diff pairs and 4 grounds. 9 blades each total.
ESD Electrostatic discharge.
Ground Unless otherwise specified the term Ground means logic
ground or signal ground, not safety ground. Also referred to
as RF Ground. See Safety Ground and RF Ground.
HP Horizontal Pitch of 5.08 mm or 0.2 inch (see IEEE 1101.1-
1998). Thus 4HP = 0.8 inch pitch.
Power Wafer A wafer providing 2 planes and 8 blades of contacts which
are intended to be used to supply prime power to a plug-in
module.
RF Ground A distributed low impedance common reference between
plug-in module circuitry/shields and other electrical
equipment (rack, other plug-in modules, and power
sources). See Safety Ground and Ground.
Safety Ground Plug-in module features, including ground path and
components that ensure hazardous voltages are not present
on accessible hardware under single fault conditions. See
Ground and RF Ground.
Single-ended (SE) wafer A single-ended wafer providing five signal blades and four
ground blades.
VME Board A plug-in module that complies with the ANSI/VITA-1.1,
VME64 Extensions standard.
Vs Notation representing Prime Power from the system to the
plug-in module.
1.4 References
The following publications may be used in conjunction with this standard.
Permission 1-1: The following documents, of the exact issues shown, contain provisions that through
reference in this text constitute provisions of this standard to the extent specified herein. Additionally,
more recent issues of applicable documents may be used provided performance, including reliability
and cost, are not adversely affected.
The following standards are available from the VMEbus International Trade Association.
http://www.vita.com

12

ANSI/VITA-1-2002 VME64
ANSI/VITA-1.1-1997 VME64 Extensions
ANSI/VITA 38-2003 System Management for VME
ANSI/VITA 46.0-2007 VPX Base Standard
ANSI/VITA 47-2005 Environments, Design and Construction, Safety, and Quality for Plug-
In Units
The following are available from their respective owners:
IEC 512-3-1976 Electromechanical Components for Electronic Equipment; Basic Testing
Procedures and Measuring Methods
IEC 60950-1:2001 Information Technology Equipment - Safety Part 1: General Requirements.
IEEE 1101.1-1998 IEEE Standards for Mechanical Core Specifications for Microcomputers Using
IEC 603-2 Connectors
IEEE 1101.2-1992 IEEE Standard for Mechanical Core Specifications for Conduction-Cooled
Eurocards
IEEE 1101.10-2002 IEEE Standard for Additional Mechanical Specifications for Microcomputers
Using the IEEE STD 1101.1-1991 Equipment Practice
IEEE 1101.11-1998 IEEE Standard for Mechanical Rear Plug-in Units Specifications for
Microcomputers Using IEEE 1101.1 and IEEE 1101.10 Equipment Practice
The I2C-Bus Specification, Version 2.1, January 2000 (Philips Semiconductor)
IEEE 1149.1-2001 IEEE Standard Test Access Port and Boundary Scan Architecture.
IPC-2221A Generic Standard on Printed Board Design

13

2 VITA 60.0 Compliance
This section is meant as a guide to designers of VITA 60.0-format plug-in modules, backplanes, and
systems to the major elements of the VITA 60.0 standard. Specific requirements for mandatory and
optional elements are defined in sections 3 through 7.
VITA 60.0 compliant plug-in modules and backplanes incorporate the following major features:
! Connectors which meet the requirements of this standard
! Connectors in sets which meet the requirements of this standard
! Keying and alignment mechanism for all slots which meet the requirements of this standard
! Adherence to the VITA 46.0-defined power rails Vs1, Vs2, Vs3, 3.3V_AUX, +/-12V_AUX
! Adherence to the VITA 46.0-defined utility signals: Geographical Address pins, Reference
Clock, Bussed Reserved for Future Use (RFU) differential pair, JTAG connections, System
Management signals, Non-Volatile Memory Read Only (NVMRO) signal, SYSRESET*, P1
Reserved Bussed signals, and P1 Reserved for Future Use (RFU) signals.
! Fabric provisioning for one or more of the various protocol layer standards
Recommendation 2-1: As many of the target applications for equipment defined by this standard fall
within conditions covered by ANSI/VITA 47, vendors should consider offering equipment compliant
with appropriate sections of the ANSI/VITA 47 standard.
3 System
This section is the same as section 3 of the VITA 46.0 standard.
4 Common Requirements
4.1 Overview
This section is the same as Section 4.1 of the VITA 46.0 standard. Changes to the Figures mentioned
in the Appendices have been made to the applicable VITA 60.0 configurations for 3U and 6U
implementations.
4.2 Connectors
This section highlights the major differences between the VITA 46.0 multi-module construction and
the monolithic VITA 60.0 construction for a daughtercard connector.
While meeting the basic P0 P2 for a 3U and P0 P6 for a 6U with guidance modules as shown in
Figure 4-1, the VITA 60.0 construction comes as a single part number, not as a series of individual
P_ components. Please Reference Tables 5-1 and 6-1 for the applicable catalog part numbers that
meet the rules for Section 4.2 in the VITA 46.0 standard.

14

Figure 4-1: VITA 60.0 Connector Identification for 3U and 6U Modules


15

Figure 4-2: Connector Identification for 3U and 6U Modules


16

Rule 4-1: VITA 60.0 plug-in modules shall utilize a single 8-wafer 7-Row connector section in
addition to between two and six 16-wafer 7-Row (or equivalent) connector sections assembled onto
a contiguous stiffener assembly as shown in Figure 4-1. The number of 16-wafer sections depends
on the size of the module and the possible incorporation of alternate user defined connector
implementations.
Rule 4-2: The connectors on a plug-in module shall be numbered as shown in Figure 4-2. Alignment
key 1 is at the top of the plug-in module assembly, adjacent to connector P0.
Observation 4-1: Figure 4-2 shows a view from the front, looking at the backplane. The use of P
suggests that the nomenclature is for the plug-in module; the backplane would be denoted with J
numbers. Note the relationship of the module PCB to the connectors.
Rule 4-3: P0 shall utilize an 8-wafer connector section.
Rule 4-4: The 8-wafer section in P0 shall be loaded with three Power wafers, in positions one, two
and three. See Section 4.8.1.
Rule 4-5: The 8-wafer section in P0 shall be loaded with three of the single-ended 5-signal/4-ground
style wafers, in positions four, five and six.
The single-ended contacts are to be used for routine low speed or non-differential housekeeping
functions, like geographical addressing and system management functions.
Rule 4-6: In P0, differential odd and even wafers shall be used in positions seven and eight.
Rule 4-7: In P0, unused differential connections provided shall be reserved for future use.
4.3 Form Factor and Outline
This section is the same as section 4.3 of the VITA 46.0 standard with the exception of the addition of
the following observation.
Observation 4-2: Figure 4-3 shows a view from the top of the backplane connector. The VITA 60.0
keying method involves insulator tangs that extend into the keying area and must be considered keep-
out areas for component placement. Detailed dimensions are available in Appendix B.
4.4 Alignment and Keying
4.4.1 Background and Assumptions
The VITA 60.0 keying method consists of a flat face on the backplane-side alignment and keying pin
that must line up with a matching flat face on the inside of a hole in the alignment-keying device on
the plug-in module. See Figure 4-3 for a pictorial representation of the VITA 60.0 keying system.

17

Figure 4-3: VITA 60.0 Keying System

4.4.1.1 Philosophy
The VITA 60.0 keying method provides 512 unique key settings on a 6U card and 64 unique key
settings on a 3U card. With this basic octal keying system, there are enough keying options to define
settings for backplane fabric types, parallel bus types, and daughter card connector types, and leave
the user with plenty of key settings to differentiate between modules within a given system.
4.4.1.2 Backplane Key
The angular position of the flat face on the backplane keying pin is controlled by inserting the keying
pin into the backplane module octagon in any position required by the user. There is no requirement
to notch or otherwise alter the round mounting hole in the backplane PWB. Keying positions of the
backplane pins can be changed in the field by the user.
4.4.1.3 Plug-in Module Key
There is a single D-Type key for the VITA 60.0 daughtercard plug-in module. It can be used with
all variations of guidance/ keying blocks in the VITA 60.0 Connector interconnect family. The key

18

has the same octal format as the backplane and can be clocked into position in the factory or by the
end-user.

19

Figure 4-4: VITA 46.0 Equivalent VITA 60.0 Key Nomenclatures

4.4.2 Definitions
This section is the same as section 4.4.2 of the VITA 46.0 standard.
4.4.3 Keying Rules
This section is the same as section 4.4.3 of the VITA 46.0 standard with the following changes to the
rules:
Rule 4-8: For the 6U case, if the High Voltage Power Input used by the plug-in module is
48V, the plug-in module voltage keying device that is installed shall be one of two types - either the
B position or the C position
Rule 4-9: For the 6U case, the preferred angle for the plug-in module voltage keying module for the
48V case is B and this shall be used unless specific system requirements for a user keying range
greater than 25 (6U modules) exist. All standard catalog 48V plug-in modules shall use this setting.
Rule 4-10: For the 6U case, if the high voltage power input used by the plug-in module is
12V, the plug-in module shall have either the A or the H alignment-key installed.
Rule 4-11: For the 6U case, the preferred angle for the plug-in module voltage keying device for the
12V case is H and this should be used unless specific system requirements for a user keying range
greater than 25 exist. All standard catalog 12V plug-in modules shall use this setting.
Rule 4-12: For the 6U case, if the plug-in module does not use any high voltage power input (Vs1
and Vs2 are no-connects), the plug-in module keying device that is installed shall be without a D-key
that will mate with a backplane keying pin positioned at any octal position.
Rule 4-13: For the 6U case, the plug-in module voltage keying device of type G shall be reserved for
future use.
Rule 4-14: To facilitate ease of system integration, standard catalog 6U plug-in modules shall be
delivered with keying devices #2 and #3 installed without D-keys, and standard catalog 3U plug-in
modules shall be delivered without D-keys in devices #1 and #2.
Observation 4-3: Users who wish to apply slot-specific keying can do so in the field or at the
assembly stage of the manufacturing process through the use of the D-keys.

20

Observation 4-4: The Alignment-keying device is designed to provide a safety ground path between
the plug-in module and the appropriate chassis grounding point.
4.5 Two Level Maintenance
This section is the same as section 4.5 of the VITA 46.0 standard.
4.6 Connector Pin Definition P0
This section is the same as section 4.6 of the VITA 46.0 standard.
4.7 Electrical Budgets for Protocol Standards
This section is the same as section 4.7 of the VITA 46.0 standard.
4.8 Signal Definition P0
This section is the same as section 4.8 of the VITA 46.0 standard with the exception of the Power
paragraph, 4.8.1. The subsections of 4.8.1 and the remainder of section 4.8 are the same as the VITA
46.0 standard.
4.8.1 Power
This section is the same as section 4.8 of the VITA 46.0 standard with the following change:
Permission 4-2: Plug-in modules may use the appropriate combination of Vs1, Vs2 and Vs3 to
accommodate the design requirements. However, to claim conformance to this standard, plug-in
modules must be capable of being inserted in a standard keyed location. See VITA 60.0, section
4.4.3.

21

Table 4-1: Power Wafer Current Ratings
These current ratings are dependent on several variables, such as:
! Heatsinking, e.g. copper plane thickness and size, connected to power pins. The above ratings
are from test data for 1 and 2 ounce copper planes within test plug-in modules and backplane.
! Thermal management, e.g. cooling method for a plug-in module. The above ratings are from
test data where cooling was to still ambient air.

!"#$ &' ()*+, -./+, 01,,+23 4.3526 /), 7'80 #+9:+,.31,+ 45;+
()*+, (<.2+ #=5>?2+;;
52 (<16 .2@ (<.A
B)@1<+
C D12>+ 0)::+, E D12>+ 0)::+,
F19G+, )/ -./+,;
$>,);; -=5>= ()*+, 5;
H5;;5:.3+@
7 -./+,; C -./+,; E -./+, 7 -./+,; C -./+,; E -./+,
01,,+23 $<<)*+@ :+,
0)23.>3 I$J
!" !$%&' &(%' (%' !!%&' &"
01,,+23 $<<)*+@ :+,
-./+, I$J
&" )&%' '' !' &&%' *"
01,,+23 $<<)*+@ :+,
0)22+>3), I$J
$" $' '' *' *' *"
4.9 Connector Pin Definition - P1
This section is the same as section 4.9 of the VITA 46.0 standard with the exception of the below
rules from section 4.9:
Rule 4-53: The connector section used in location P1 shall be loaded with 8 odd and 8 even
differential wafers. The common P1 pinout for VITA 60.0 shall be identical to the common P1 pinout
for VITA 46.0, Table 4-6. The P1 signal definitions for VITA 60.0 shall be identical to the P1 signal
definitions for VITA 46.0, Table 4-7.
Rule 4-54: Single-ended pins in P1, Row G. Wafer 1 shall be reserved for future use. The plug-in
module shall not connect/route/provide electrical signals to these pins.
It is expected that the differential pins will be used for serial fabrics.

22

5 3U Module
5.1 Overview 3U Module
This section is the same as section 5.1 of the VITA 46.0 standard.
5.2 Connectors 3U Module
The VITA 60.0 3U connector is a monolithic connector incorporating P0, P1 and P2 modular
increments into a single entity on a contiguous stiffener assembly. Single-ended and differential
wafers can be located in P2. RF and Optical solutions may also be incorporated into the P2 location.
Please refer to Table 5-1 for individual part numbers.
Table 5-1: 3U VITA 60.0 3U Module Connectors
!"##$%&"' )*'& +$,%'-.&-"# +$,%'-.&-"#
0, 1 ulfferenLlal, 2 ulfferenLlal See SecLlon 4.2 3u vl1A 60.0 wlLh ulfferenLlal 2
1

0, 1 ulfferenLlal, 2 Slngal-Lnded See SecLlon 4.2 3u vl1A 60.0 wlLh Slngle-Lnded 2
2

5.3 Keying 3U Module
Rule 5-6: Two alignment-keying devices shall be used, located as defined in Section 4 and the
Appendices.
5.4 Connector Pin Definition 3U Module P2
5.4.1 Standard Connector P2
Rule 5-7: When a standard connector is used in location P2, it shall be loaded with sixteen wafers.
The type of wafers used depends on the protocol specification in use; wafers may be either
differential odd and even, or the single-ended type.
Rule 5-8: When a standard VITA 60.0 connector is used in location P2, it shall utilize either all
differential wafers (alternating odd and even), or all single-ended wafers.
5.4.2 Recommended Location on 3U module for Application-Specific Connector
This section is the same as section 5.4.2 of the VITA 46.0 standard.
5.4.2.1 Differential Connector Allocation
This section is the same as section 5.4.2.1 of the VITA 46.0 standard.

1
Amphenol Backplane Systems - Part Number VP773-10001 or equivalent
2
Amphenol Backplane Systems Part Number VP773-10002 or equivalent

23

5.4.2.2 Single-ended Connector Allocation
This section is the same as section 5.4.2.2 of the VITA 46.0 standard.
6 Module
6.1 Overview
This section is the same as section 6.1 of the VITA 46.0 standard.
6.2 Connectors
Rule 6-2: VITA 60.0 6U plug-in modules shall utilize one 8-wafer connector section, plus one, two,
three, four, five or six 16-wafer connector sections assembled onto a contiguous stiffener assembly
that includes three alignment/ keying blocks per Figures 4-1 and 4-2.
Rule 6-3: The connectors shall be denoted as P0, P1, P2, P3, P4, P5 and P6.
Numbering of the connector sections is shown in Section 4.
Rule 6-4: P0 and P1 shall be as defined in Section 4.
Rule 6-5: P2 through P4 (and generally P5 and P6) shall utilize 16-wafer connector sections. More
detail is given in Section 4.
Observation 6-2: A standard differential connector section with 8 odd and 8 even differential wafers
has 144 pins; 72 GNDS, 64 differential signals, 8 single-ended signals. A single-ended connector
section with 16 wafers has 144 pins, 64 GNDS, 80 single-ended signals.

24

Table 6-1: 6U VITA 60.0 3U Module Connectors
3


3

AMPHENOL PART NUMBER OUTLINE FOR VITA 60.0 VARIATIONS (Standard Connector No. for Module Card Shown) Amphenol
Backplane Systems part numbers, or equivalent
6U
Configuration
Part No.
6U
Configuration
Part No.
6U
Configuration
Part No.
6U
Configuration
Part No.
Variant C VP776-10001 Variant L VP776-10009 Variant T VP776-10017 Variant AB VP776-10025
Variant D VP776-10002 Variant M VP776-10010 Variant U VP776-10018 Variant AC VP776-10026
Variant E VP776-10003 Variant N VP776-10011 Variant V VP776-10019 Variant AD VP776-10027
Variant F VP776-10004 Variant O VP776-10012 Variant W VP776-10020 Variant AE VP776-10028
Variant G VP776-10005 Variant P VP776-10013 Variant X VP776-10021 Variant AF VP776-10029
Variant H VP776-10006 Variant Q VP776-10014 Variant Y VP776-10022 Variant AG VP776-10030
Variant J VP776-10007 Variant R VP776-10015 Variant Z VP776-10023 Variant AH VP776-10031
Variant K VP776-10008 Variant S VP776-10016 Variant AA VP776-10024 Variant AI VP776-10032

Configuration P0 P1 P2 P3 P4 P5 P6
Variant C (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Dif f erential Dif f erential
Variant D (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Dif f erential Dif f erential
Variant E (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Dif f erential Dif f erential
Variant F (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Dif f erential Dif f erential
Variant G (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Dif f erential Dif f erential
Variant H (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Dif f erential Dif f erential
Variant J (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Dif f erential Dif f erential
Variant K (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Dif f erential Dif f erential
Variant L (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Single Ended Dif f erential
Variant M (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Single Ended Dif f erential
Variant N (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Single Ended Dif f erential
Variant O (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Single Ended Dif f erential
Variant P (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Single Ended Dif f erential
Variant Q (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Single Ended Dif f erential
Variant R (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Single Ended Dif f erential
Variant S (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Single Ended Dif f erential
Variant T (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Dif f erential Single Ended
Variant U (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Dif f erential Single Ended
Variant V (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Dif f erential Single Ended
Variant W (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Dif f erential Single Ended
Variant X (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Dif f erential Single Ended
Variant Y (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Dif f erential Single Ended
Variant Z (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Dif f erential Single Ended
Variant AA (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Dif f erential Single Ended
Variant AB (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Single Ended Single Ended
Variant AC (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Single Ended Single Ended
Variant AD (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Single Ended Single Ended
Variant AE (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Single Ended Single Ended
Variant AF (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Single Ended Single Ended
Variant AG (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Single Ended Single Ended
Variant AH (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Single Ended Single Ended
Variant AI (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Single Ended Single Ended

25

6.3 Alignment and Keying
This section is the same as section 6.3 of the VITA 46.0 standard.
6.4 Connector Pin Definition
6.4.1 Connector P2
Rule 6-7: The connector used in location P2 shall be loaded with sixteen wafers.
The type of wafers used depends on the protocol specification in use; wafers may be either odd and
even differential, or the single-ended type.
Rule 6-8: The connector used in location P2 shall utilize either all differential wafers, or all single-
ended wafers.
6.4.1.1 Differential Connector Allocation
Rule 6-9: When the protocol specification calls for differential wafers in P2, the pins in connector P2
shall be identical to those defined in Table 6-2 of the VITA 46.0 standard.
6.4.1.2 Single-Ended Connector Allocation
Rule 6-10: When the protocol specification calls for single-ended wafers in P2, the pins in connector
P2 shall be identical to those defined in Table 6-3 of the VITA 46.0 standard.
6.4.2 Connector P3
Rule 6-11: The connector used in location P3 shall be loaded with sixteen wafers.
The type of wafers used depends on the protocol specification in use; wafers may be either
differential, or the single-ended type.
Rule 6-12: The connector shall utilize all odd and even differential wafers, or all single-ended
wafers.
6.4.2.1 Differential Connector Allocation
Rule 6-13: When the protocol specification calls for differential wafers in P3, the pins in connector
P3 shall be identical to those defined in Table 6-4 of the VITA 46.0 standard.
6.4.2.2 Single-ended Connector Allocation
Rule 6-14: When the protocol specification calls for single-ended wafers in P3, the pins in connector
P3 shall be identical to those defined in Table 6.5 of the VITA 46.0 standard.

26

6.4.3 Connector P4
Rule 6-15: The connector used in location P4 shall be loaded with sixteen wafers.
The type of wafers used depends on the protocol specification in use; wafers may be either odd and
even differential, or the single-ended type.
Rule 6-16: The connector shall utilize all differential wafers, or all single-ended wafers.
6.4.3.1 Differential Connector Allocation
Rule 6-17: When the protocol specification calls for differential wafers in P4, the pins in connector
P4 shall be identical to those defined in Table 6.6 of the VITA 46.0 standard.
6.4.3.2 Single-Ended Connector Allocation
Rule 6-18: When the protocol specification calls for single-ended wafers in P4, the pins in connector
P4 shall be identical to those defined in Table 6.7 of the VITA 46.0 standard.
6.4.4 Connector P5
Rule 6-19: The connector used in location P5 shall be loaded with sixteen wafers.
The type of wafers used depends on the protocol specification in use; wafers may be either odd and
even differential, or the single-ended type.
Rule 6-20: The connector shall utilize all differential wafers, or all single-ended wafers.
6.4.4.1 Differential Connector Allocation
Rule 6-21: When the protocol specification calls for differential wafers in P5, the pins in connector
P5 shall be identical to those defined in Table 6.8 of the VITA 46.0 standard.
6.4.4.2 Single-Ended Connector Allocation
Rule 6-22: When the protocol specification calls for single-ended wafers in P5, the pins in connector
P5 shall be identical to those defined in Table 6.9 of the VITA 46.0 standard.
6.4.5 Connector P6
Rule 6-23: The connector used in location P6 shall be loaded with sixteen wafers.

The type of wafers used depends on the protocol specification in use; wafers may be either odd and
even differential, or the single-ended type.
Rule 6-24: The connector shall utilize all differential wafers, or all single-ended wafers.

27

6.4.5.1 Differential Connector Allocation
Rule 6-25: When the protocol specification calls for differential wafers in P6, the pins in connector
P6 shall be identical to those defined in Table 6-10 of the VITA 46.0 standard.
6.4.5.2 Single-ended Connector Allocation
Rule 6-26: When the protocol specification calls for single-ended wafers in P6, the pins in connector
P6 shall be identical to those defined in Table 6-11 of the VITA 46.0 standard.
6.4.6 Locations on 6U module for User Defined Application-Specific Connectors
This section is the same as section 6.4.6 of the VITA 46.0 standard.
7 Backplanes
This section is the same as section 7 of the VITA 46.0 standard with the following exceptions:
Connector Selection paragraph, 7.1.3; Backplane Keying paragraph, 7.8; Preventing Damage from
Backwards Plug-In Module Insertion, 7.9.

7.1.3 Connector Selection
This section is the same as section 7.1.3 of the VITA 46.0 standard with the following updated
observation.
Observation 7-3: The backplane connectors do differentiate among power, single-ended and
differential wafers on the mating plug-in module and must be loaded into the individual backplane
modules accordingly.
User defined connectors must be compatible with the selected plug-in module connectors. As defined
in Table 7-1.

28

Table 7-1: Backplane Connector Cross-reference
4



4

AMPHENOL PART NUMBER OUTLINE FOR VITA 60.0 VARIATIONS (Standard Connector No. for Backplane Shown) Amphenol
Backplane Systems part numbers, or equivalent
6U
Configuration
Part No.
6U
Configuration
Part No.
6U
Configuration
Part No.
6U
Configuration
Part No.
Variant C VJ776-10001 Variant L VJ776-10009 Variant T VJ776-10017 Variant AB VJ776-10025
Variant D VJ776-10002 Variant M VJ776-10010 Variant U VJ776-10018 Variant AC VJ776-10026
Variant E VJ776-10003 Variant N VJ776-10011 Variant V VJ776-10019 Variant AD VJ776-10027
Variant F VJ776-10004 Variant O VJ776-10012 Variant W VJ776-10020 Variant AE VJ776-10028
Variant G VJ776-10005 Variant P VJ776-10013 Variant X VJ776-10021 Variant AF VJ776-10029
Variant H VJ776-10006 Variant Q VJ776-10014 Variant Y VJ776-10022 Variant AG VJ776-10030
Variant J VJ776-10007 Variant R VJ776-10015 Variant Z VJ776-10023 Variant AH VJ776-10031
Variant K VJ776-10008 Variant S VJ776-10016 Variant AA VJ776-10024 Variant AI VJ776-10032

Configuration J0 J1 J2 J3 J4 J5 J6
Variant C (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Dif f erential Dif f erential
Variant D (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Dif f erential Dif f erential
Variant E (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Dif f erential Dif f erential
Variant F (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Dif f erential Dif f erential
Variant G (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Dif f erential Dif f erential
Variant H (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Dif f erential Dif f erential
Variant J (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Dif f erential Dif f erential
Variant K (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Dif f erential Dif f erential
Variant L (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Single Ended Dif f erential
Variant M (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Single Ended Dif f erential
Variant N (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Single Ended Dif f erential
Variant O (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Single Ended Dif f erential
Variant P (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Single Ended Dif f erential
Variant Q (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Single Ended Dif f erential
Variant R (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Single Ended Dif f erential
Variant S (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Single Ended Dif f erential
Variant T (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Dif f erential Single Ended
Variant U (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Dif f erential Single Ended
Variant V (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Dif f erential Single Ended
Variant W (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Dif f erential Single Ended
Variant X (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Dif f erential Single Ended
Variant Y (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Dif f erential Single Ended
Variant Z (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Dif f erential Single Ended
Variant AA (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Dif f erential Single Ended
Variant AB (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Single Ended Single Ended
Variant AC (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Single Ended Single Ended
Variant AD (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Single Ended Single Ended
Variant AE (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Single Ended Single Ended
Variant AF (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Single Ended Single Ended
Variant AG (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Single Ended Single Ended
Variant AH (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Single Ended Single Ended
Variant AI (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Single Ended Single Ended

29

7.8 Backplane Keying
Refer to section 4.4 for background information and definitions that apply to VITA 60.0 keying for
both plug-in modules and backplanes.
7.9 Preventing Damage from Backwards Plug-in Module Insertion
This section is the same as section 7.9 of the VITA 46.0 standard with exception of Observation 7-23.
For 6U plug-in modules, the short center alignment keying pin in VITA 60.0 will not result in
damage to the P4 connector resulting from a backwards installed plug-in module.

30

Appendix A Plug-in Module Assembly Drawings
Figure A-1 3U Air Cooled Module Layout


31

Figure A-2 3U Conduction Cooled Layout

32

Figure A-3 6U Air Cooled Layout

33

Figure A-4 6U Conduction Cooled Layout


34

Figure A-5 3U Conduction Cooled Module End View


35

Figure A-6 6U Conduction Cooled Module End View


36

Figure A-7 3U Chassis Side Wall


37

Figure A-8 Conduction Cooled Module Side View


38

Appendix B Backplane Printed Circuit Board Fabrication Drawings
Figure B-1 3U Air Cooled Backplane


39

Figure B-2 6U Air Cooled Backplane


40

Figure B-3 3U Conduction Cooled Backplane, Plan View


41

Figure B-4 6U Conduction Cooled Backplane, Plan View


42

Figure B-5 6U Backplane, End View


43

Figure B-6 3U Backplane, End View


44

Appendix C Plug-in Module Printed Circuit Board Fabrication
Drawings
Figure C-1 3U PCB Fabrication Drawing (viewed from Primary Side)


45

Figure C-2 6U PCB Fabrication Drawing (viewed from Primary Side)

Das könnte Ihnen auch gefallen