This standard provides an alternate connector to the one specified in the VITA 46. VPX Baseline Standard. A VITA 60. Module will not plug into a VITA 46.0. Backplane and vice versa. The use of American National Standards is completely voluntary.
This standard provides an alternate connector to the one specified in the VITA 46. VPX Baseline Standard. A VITA 60. Module will not plug into a VITA 46.0. Backplane and vice versa. The use of American National Standards is completely voluntary.
This standard provides an alternate connector to the one specified in the VITA 46. VPX Baseline Standard. A VITA 60. Module will not plug into a VITA 46.0. Backplane and vice versa. The use of American National Standards is completely voluntary.
PH: 480-837-7486 Email: info@vita.com URL: http://www.vita.com Approved American National Standard ANSI/VITA 60.0 Alternative Connector for VPX Abstract This standard, VITA 60.0 Alternative Connector for VPX, provides an alternate connector to the one specified in the VITA 46.0 VPX Baseline Standard. Because the 46.0 and the 60.0 connectors are not intermateable, a VITA 60.0 module will not plug into a VITA 46.0.0 backplane and vice versa. However, the VITA 60.0 standard provides VPX users with the flexibility to choose a VPX module and backplane connector combination for their specific application requirements.
Approved February 2012 American National Standards Institute, Inc.
American National Standard Approval of an American National Standard requires verification by ANSI that the requirements for due process, consensus, and other criteria for approval have been met by the standards developer.
Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be made toward their resolution.
The use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone, whether he has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes, or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standard Institute. Requests for interpretations should be addressed to the secretariat or sponsor whose name appears on the title page of this standard.
CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken periodically to reaffirm, revise, or withdraw this standard. Purchases of American National Standards may receive current information on all standard by calling or writing the American National Standards Institute.
NOTE The users attention is called to the possibility that compliance with this standard may require use of an invention covered by patent rights.
By publication of this standard, no position is taken with respect to the validity of this claim or of any patent rights in connection therewith. The patent holder has, however, filed a statement of willingness to grant a license under these rights on reasonable and nondiscriminatory terms and conditions to applicants desiring to obtain such a license. Details may be obtained from the standards developer. Published by
VMEbus International Trade Association (VITA) PO Box 19658, Fountain Hills, AZ 85269 Copyright 2012 by VMEbus International Trade Association
All rights reserved.
Permission of the publisher is required to reproduce this document or any part of it. Printed in the United States of America - R1.0 ISBN 1-885731-69-8
7.1.3 Connector Selection ........................................................................................................................................... 27 7.8 Backplane Keying ................................................................................................................................. 29 7.9 Preventing Damage from Backwards Plug-in Module Insertion ........................................................... 29 List of Figures FIGURE 4-1: VITA 60.0 CONNECTOR IDENTIFICATION FOR 3U AND 6U MODULES ............................... 14 FIGURE 4-2: CONNECTOR IDENTIFICATION FOR 3U AND 6U MODULES .................................................. 15 FIGURE A-1 3U AIR COOLED MODULE LAYOUT .................................................................................... 30 FIGURE A-2 3U CONDUCTION COOLED LAYOUT ................................................................................... 31 FIGURE A-3 6U AIR COOLED LAYOUT ................................................................................................... 32 FIGURE A-4 6U CONDUCTION COOLED LAYOUT ................................................................................... 33 FIGURE A-5 3U CONDUCTION COOLED MODULE END VIEW ................................................................. 34 FIGURE A-6 6U CONDUCTION COOLED MODULE END VIEW ................................................................. 35 FIGURE A-7 3U CHASSIS SIDE WALL ..................................................................................................... 36 FIGURE A-8 CONDUCTION COOLED MODULE SIDE VIEW ...................................................................... 37 FIGURE B-1 3U AIR COOLED BACKPLANE ............................................................................................. 38 FIGURE B-2 6U AIR COOLED BACKPLANE ............................................................................................. 39 FIGURE B-3 3U CONDUCTION COOLED BACKPLANE, PLAN VIEW ......................................................... 40 FIGURE B-4 6U CONDUCTION COOLED BACKPLANE, PLAN VIEW ......................................................... 41 FIGURE B-5 6U BACKPLANE, END VIEW ............................................................................................... 42 FIGURE C-1 3U PCB FABRICATION DRAWING (VIEWED FROM PRIMARY SIDE) ..................................... 44 FIGURE C-2 6U PCB FABRICATION DRAWING (VIEWED FROM PRIMARY SIDE) ..................................... 45 LIST OF TABLES TABLE 4-1: POWER WAFER CURRENT RATINGS .................................................................................... 21 TABLE 5-1: 3U VITA 60.0 3U MODULE CONNECTORS .......................................................................... 22 TABLE 6-1: 6U VITA 60.0 3U MODULE CONNECTORS .......................................................................... 24 TABLE 7-1: BACKPLANE CONNECTOR CROSS-REFERENCE ..................................................................... 28
5
Abstract This standard, VITA 60.0 Alternate Connector for VPX, provides an alternative connector to the one specified in the VITA 46.0 VPX Baseline Standard. Because the 46.0 and the 60.0 connectors are not intermateable, a VITA 60.0 module will not plug into a VITA 46.0.0 backplane and vice versa. However, the VITA 60.0 standard provides VPX users with the flexibility to choose a VPX module and backplane connector combination for their specific application requirements Foreword VME has been the de-facto bus standard for Commercial off the Shelf (COTS ) Circuit Card Assemblies since the 1980s. VME boards have proven to be remarkably capable of evolving to support newer technologies with innovations such as VME Subsystem Bus, PCI Mezzanine Cards (PMCs) and VME320. However, advances in technologies, particularly in interconnects, have demonstrated the need for an advance in system development. This advance needs to accommodate high speed interconnect, particularly serial interconnects, and higher power delivery in concert with better heat removal. This standard addresses these needs in the context of IEEE 1101 form factor modules. Other specifications may address alternate outlines, such as VITA-48. Because electronics miniaturization is driving the plug-in module I/O count, most system interconnects will need: ! Multi-gigabit differential technology ! Core computing cluster switched fabrics ! Serial RapidIO, PCI Express, Hypertransport, Inifiniband or 10G Ethernet ! Sufficient ports to enable distributed switching or centralized switching The plethora of high-speed interfaces available for tomorrows plug-in modules include: ! Network interfaces ! Digital video ! Mass storage interface ! FPGA-based inter-board connections ! Custom sensor interfaces VITA 60.0 provides an intermountable alternate to the VITA 46.0 connector for VME users: ! To leverage the broad spectrum of high-speed interconnect technologies ! Backward compatibility with VME bus electrical, software and selected mechanicals ! Enables heterogeneous architectures which preserve existing investments in COTS-based systems ! Addresses both 3U and 6U form factors ! Harsh environment fit designed-in up front in the standard ! Rugged air or conduction-cooled form factors ! High value placed on rear-panel I/O ! High-speed connector survivability/compliance
6
! Connector with ESD protection and options for handling covers to accommodate 2-level maintenance. ! Space constrained high compute density applications Other Defense and Aerospace market needs are also under consideration. Standards Innovation is the COTS Industrys Most Compelling Value Proposition. Working Group Members The Working Group members as listed on the sign-up sheet from the 18 Nov 2008 meeting including additional contributing members since that date. NAME COMPANY Andrew Shieh CSP, Inc. Andrew Stringer Lockheed Martin Corporation Ben Jeffrey Molex Bill Hanna Boeing Bill Northey FCI Electronics Bob Patterson Tyco Electronics Bob Sullivan Curtiss-Wright Controls Electronic Systems Bruce Thomas Curtiss Wright Chad Siemering Rockwell Collins Dan Golden Boeing Dan Toohey Mercury Computer David Dix Amphenol David Pepper GE Embedded Systems Dean Holman Mercury Computer Earle Olson Tyco Electronics Ed Garstkiewicz Harting Inc. of North America Fred Fons Foxconn Frank Hom APW Electronic Solutions Gerard Drewek General Dynamics Gerry Marino Lytron Inc. Greg Powers Tyco Electronics Greg Rocco Mercury Ivan Straznicky Curtiss-Wright Controls Embedded Jaret Paul Amphenol Jim Goldenberg GE-IP Jim Reedy DRS-SS Jim Vana 3M Joe Brokesh Curtiss-Wright John Rynearson VITA Lori Bechtold Boeing Mac Rush Emerson Melissa Heckman Bustronic Corporation Michael Biemer Northop Grumman Michael Munroe Bustronics Michael Thompson Pentair Electronic Packaging Michele York Amphenol Mike Gust Mercury Computer Mike Hasenfratz Northrop Grumman Pat Shaw GD Canada Paul Griffith Concurrent Technologies Pete Jha Curtiss Wright Rex Harvey Parker
7
NAME COMPANY Richard Hodges Parker Rick Stevens LMCO Robert Ford Boeing Ronald Schoomaker Lockheed Martin Scott Goedeke Northrop Grumman Stephen Cecil NAVSEA Crane Division Steve Lawler EPT Steve Konsowski Northrop Grumman Steve Birch TEK Microsystems Terry Dilling General Dynamics Vince Luca Amphenol Wolfgang Schmidt EPT Comments, Corrections and/or Additions Anyone wishing to provide comments, corrections and/or additions to this standard, please direct them to the VITA technical director at techdir@vita.com, www.vita.com. VSO and Other Standards Should anyone want information on other standards being developed by the VSO, VME Product Directories, VME Handbooks, or general information on the embedded systems market, please contact the VITA office at the address or telephone number given on the front cover.
8
1 Introduction VITA 60.0 provides an alternative connector to the one specified in VITA 46.0, VPX Baseline Standard. Because the 46.0 and the 60.0 connectors are not intermateable a VITA 60.0 module will not plug into a VITA 46.0 backplane and vice versa. However, the VITA 60.0 standard provides VPX users with the flexibility to choose a VPX module and backplane connector combination for their specific application requirements. This document provides a standard mechanical format for standardization of switched serial interconnects for VMEbus applications, with specific concern taken to allow deployment in ruggedized environments. There are many candidate technologies for switched serial interconnects. These include without limitation: Ethernet through 10 GBit, Fibre Channel, InfiniBand, Serial RapidIO, PCI Express, Hypertransport, Infiniband and others. Each technology has its pros and cons, and the market will determine which ones will ultimately survive. The data plane proposed defines a playing field on which users may implement their preferred serial interconnect. 1.1 Objectives The objectives of this standard are: ! Define a 6U and 3U Eurocard format family of plug-in modules suitable for ruggedized use utilizing the VITA 60.0 interconnects. ! Define a scalable high-speed connector that can bridge from < 1 Gbps up to 10 Gbps data rates. ! Maintain current VITA 46.0 mechanical standardization format for referenced switched serial interconnect technologies. ! Make provision for additional I/O capability at the plug-in module level including RF and Optical interconnects. ! Maintain current VITA 46.0 option of two level maintenance capable Line Replaceable Modules. 1.2 VITA 60.0 Overview The VITA 60.0 standard is a supplement to the VITA 46.0 family of standards outlining only the areas of dissimilarity to the base standard. Alternate Connector for VPX is the name given to this standard. For reference purposes, at the time of publication the following protocol standards had been defined. Please consult VITA for a current list. VITA 46.0 The VITA 60.0 base standard includes features drawn from IEEE 1101.1 and IEEE 1101.2 (for air cooled and conduction cooled plug-in modules, respectively). These features are evident in the mechanical drawings provided. The VITA 60.0 base standard defines physical features that enable high-speed communication in a compliant system. These features include: a 6U by 160mm by 4HP pitch Eurocard format board with
9
high speed differential connectors, a 6U by 160mm by 4HP pitch Eurocard format board with a combination of high speed differential and single-ended connectors, and the backplane/chassis infrastructure needed to support these features. The base standard also defines similar physical features for 3U by 160mm by 4HP pitch Eurocard format, providing the same two types of connector options discussed above for 6U plug-in modules. Many features called for in the base specification will be compatible with the requirements of other standards, such as VITA-48, but this standard concerns only the IEEE 1101 compatible applications. This base standard also defines alignment and keying features used to protect the connector system. The base standard does not address the possible serial fabric configurations available in systems which utilize the standard. While the base standard does not address the use of ANSI/VITA-1.1 or VITA-41 plug-in modules, or modules which are constructed to the mechanical requirements of VITA-48, chassis and backplanes can be constructed which provide compatibility with plug-in modules built to these standards. The dot specifications allow the use of the single-ended connector allocation for parallel busses, such as VME or PCI, completing the compatibility between older standards and this one. 1.3 Terminology 1.3.1 Specification Key Words To avoid confusion and to make very clear what the requirements for compliance are, many of the paragraphs in this standard are labeled with keywords that indicate the type of information they contain. These keywords are listed below: ! Rule ! Recommendation ! Suggestion ! Permission ! Observation Any text not labeled with one of these keywords should be interpreted as descriptive in nature. These will be written in either a descriptive or a narrative style. The keywords are used as follows:
10
Rule <chapter>-<number>: Rules form the basic framework of this standard. They are sometimes expressed in text form and sometimes in the form of figures, tables or drawings. All rules shall be followed to ensure compatibility between board and backplane designs. All rules use the shall or shall not words to emphasize the importance of the rule. The shall or shall not words are reserved exclusively for stating rules in this standard and are not used for any other purpose. Recommendation <chapter>-<number>: Wherever a recommendation appears, designers would be wise to take the advice given. Doing otherwise might result in poor performance or awkward problems. Recommendations found in this standard are based on experience and are provided to designers to speed their traversal of the learning curve. All recommendations use the should or should not words to emphasize the importance of the recommendation. The should or should not words are reserved exclusively for stating recommendations in this standard and are not used for any other purpose. Suggestion <chapter>-<number>: A suggestion contains advice, which is helpful but not vital. The reader is encouraged to consider the advice before discarding it. Some design decisions that need to be made are difficult until experience has been gained. Suggestions are included to help a designer who has not yet gained this experience. Permission <chapter>-<number>: In some cases a rule does not specifically prohibit a certain design approach, but the reader might be left wondering whether that approach might violate the spirit of the rule or whether it might lead to some subtle problem. Permissions reassure the reader that a certain approach is acceptable and will cause no problems. All permissions use the may words to emphasize the importance of the permission. The lower-case may words are reserved exclusively for stating permissions in this standard and are not used for any other purpose. Observation <chapter>-<number>: Observations do not offer any specific advice. They usually follow naturally from what has just been discussed. They spell out the implications of certain rules and bring attention to things that might otherwise be overlooked. They also give the rationale behind certain rules so that the reader understands why the rule must be followed. 1.3.2 VITA 60.0 Definitions The following terms are used within the body of the specification. In this context, they have the following meanings: Term Definition 2-level maintenance (Two Level Maintenance) A maintenance system where plug in modules are the field replaceable units; a subset of whose requirements are that
11
Term Definition the module provides both mechanical and ESD protection. Air cooled A plug-in module which is intended to have heat removed by transfer to an air stream flowing over the module Chassis Ground See Safety Ground. Conduction cooled a plug-in module which is intended to have heat removed by transfer to the chassis through mechanical contact with a chassis component Differential Wafer A wafer designed for the connection of high speed differential pairs (up to 10 Gbps), each of which has a minimum of 2 diff pairs and 4 grounds. 9 blades each total. ESD Electrostatic discharge. Ground Unless otherwise specified the term Ground means logic ground or signal ground, not safety ground. Also referred to as RF Ground. See Safety Ground and RF Ground. HP Horizontal Pitch of 5.08 mm or 0.2 inch (see IEEE 1101.1- 1998). Thus 4HP = 0.8 inch pitch. Power Wafer A wafer providing 2 planes and 8 blades of contacts which are intended to be used to supply prime power to a plug-in module. RF Ground A distributed low impedance common reference between plug-in module circuitry/shields and other electrical equipment (rack, other plug-in modules, and power sources). See Safety Ground and Ground. Safety Ground Plug-in module features, including ground path and components that ensure hazardous voltages are not present on accessible hardware under single fault conditions. See Ground and RF Ground. Single-ended (SE) wafer A single-ended wafer providing five signal blades and four ground blades. VME Board A plug-in module that complies with the ANSI/VITA-1.1, VME64 Extensions standard. Vs Notation representing Prime Power from the system to the plug-in module. 1.4 References The following publications may be used in conjunction with this standard. Permission 1-1: The following documents, of the exact issues shown, contain provisions that through reference in this text constitute provisions of this standard to the extent specified herein. Additionally, more recent issues of applicable documents may be used provided performance, including reliability and cost, are not adversely affected. The following standards are available from the VMEbus International Trade Association. http://www.vita.com
12
ANSI/VITA-1-2002 VME64 ANSI/VITA-1.1-1997 VME64 Extensions ANSI/VITA 38-2003 System Management for VME ANSI/VITA 46.0-2007 VPX Base Standard ANSI/VITA 47-2005 Environments, Design and Construction, Safety, and Quality for Plug- In Units The following are available from their respective owners: IEC 512-3-1976 Electromechanical Components for Electronic Equipment; Basic Testing Procedures and Measuring Methods IEC 60950-1:2001 Information Technology Equipment - Safety Part 1: General Requirements. IEEE 1101.1-1998 IEEE Standards for Mechanical Core Specifications for Microcomputers Using IEC 603-2 Connectors IEEE 1101.2-1992 IEEE Standard for Mechanical Core Specifications for Conduction-Cooled Eurocards IEEE 1101.10-2002 IEEE Standard for Additional Mechanical Specifications for Microcomputers Using the IEEE STD 1101.1-1991 Equipment Practice IEEE 1101.11-1998 IEEE Standard for Mechanical Rear Plug-in Units Specifications for Microcomputers Using IEEE 1101.1 and IEEE 1101.10 Equipment Practice The I2C-Bus Specification, Version 2.1, January 2000 (Philips Semiconductor) IEEE 1149.1-2001 IEEE Standard Test Access Port and Boundary Scan Architecture. IPC-2221A Generic Standard on Printed Board Design
13
2 VITA 60.0 Compliance This section is meant as a guide to designers of VITA 60.0-format plug-in modules, backplanes, and systems to the major elements of the VITA 60.0 standard. Specific requirements for mandatory and optional elements are defined in sections 3 through 7. VITA 60.0 compliant plug-in modules and backplanes incorporate the following major features: ! Connectors which meet the requirements of this standard ! Connectors in sets which meet the requirements of this standard ! Keying and alignment mechanism for all slots which meet the requirements of this standard ! Adherence to the VITA 46.0-defined power rails Vs1, Vs2, Vs3, 3.3V_AUX, +/-12V_AUX ! Adherence to the VITA 46.0-defined utility signals: Geographical Address pins, Reference Clock, Bussed Reserved for Future Use (RFU) differential pair, JTAG connections, System Management signals, Non-Volatile Memory Read Only (NVMRO) signal, SYSRESET*, P1 Reserved Bussed signals, and P1 Reserved for Future Use (RFU) signals. ! Fabric provisioning for one or more of the various protocol layer standards Recommendation 2-1: As many of the target applications for equipment defined by this standard fall within conditions covered by ANSI/VITA 47, vendors should consider offering equipment compliant with appropriate sections of the ANSI/VITA 47 standard. 3 System This section is the same as section 3 of the VITA 46.0 standard. 4 Common Requirements 4.1 Overview This section is the same as Section 4.1 of the VITA 46.0 standard. Changes to the Figures mentioned in the Appendices have been made to the applicable VITA 60.0 configurations for 3U and 6U implementations. 4.2 Connectors This section highlights the major differences between the VITA 46.0 multi-module construction and the monolithic VITA 60.0 construction for a daughtercard connector. While meeting the basic P0 P2 for a 3U and P0 P6 for a 6U with guidance modules as shown in Figure 4-1, the VITA 60.0 construction comes as a single part number, not as a series of individual P_ components. Please Reference Tables 5-1 and 6-1 for the applicable catalog part numbers that meet the rules for Section 4.2 in the VITA 46.0 standard.
14
Figure 4-1: VITA 60.0 Connector Identification for 3U and 6U Modules
15
Figure 4-2: Connector Identification for 3U and 6U Modules
16
Rule 4-1: VITA 60.0 plug-in modules shall utilize a single 8-wafer 7-Row connector section in addition to between two and six 16-wafer 7-Row (or equivalent) connector sections assembled onto a contiguous stiffener assembly as shown in Figure 4-1. The number of 16-wafer sections depends on the size of the module and the possible incorporation of alternate user defined connector implementations. Rule 4-2: The connectors on a plug-in module shall be numbered as shown in Figure 4-2. Alignment key 1 is at the top of the plug-in module assembly, adjacent to connector P0. Observation 4-1: Figure 4-2 shows a view from the front, looking at the backplane. The use of P suggests that the nomenclature is for the plug-in module; the backplane would be denoted with J numbers. Note the relationship of the module PCB to the connectors. Rule 4-3: P0 shall utilize an 8-wafer connector section. Rule 4-4: The 8-wafer section in P0 shall be loaded with three Power wafers, in positions one, two and three. See Section 4.8.1. Rule 4-5: The 8-wafer section in P0 shall be loaded with three of the single-ended 5-signal/4-ground style wafers, in positions four, five and six. The single-ended contacts are to be used for routine low speed or non-differential housekeeping functions, like geographical addressing and system management functions. Rule 4-6: In P0, differential odd and even wafers shall be used in positions seven and eight. Rule 4-7: In P0, unused differential connections provided shall be reserved for future use. 4.3 Form Factor and Outline This section is the same as section 4.3 of the VITA 46.0 standard with the exception of the addition of the following observation. Observation 4-2: Figure 4-3 shows a view from the top of the backplane connector. The VITA 60.0 keying method involves insulator tangs that extend into the keying area and must be considered keep- out areas for component placement. Detailed dimensions are available in Appendix B. 4.4 Alignment and Keying 4.4.1 Background and Assumptions The VITA 60.0 keying method consists of a flat face on the backplane-side alignment and keying pin that must line up with a matching flat face on the inside of a hole in the alignment-keying device on the plug-in module. See Figure 4-3 for a pictorial representation of the VITA 60.0 keying system.
17
Figure 4-3: VITA 60.0 Keying System
4.4.1.1 Philosophy The VITA 60.0 keying method provides 512 unique key settings on a 6U card and 64 unique key settings on a 3U card. With this basic octal keying system, there are enough keying options to define settings for backplane fabric types, parallel bus types, and daughter card connector types, and leave the user with plenty of key settings to differentiate between modules within a given system. 4.4.1.2 Backplane Key The angular position of the flat face on the backplane keying pin is controlled by inserting the keying pin into the backplane module octagon in any position required by the user. There is no requirement to notch or otherwise alter the round mounting hole in the backplane PWB. Keying positions of the backplane pins can be changed in the field by the user. 4.4.1.3 Plug-in Module Key There is a single D-Type key for the VITA 60.0 daughtercard plug-in module. It can be used with all variations of guidance/ keying blocks in the VITA 60.0 Connector interconnect family. The key
18
has the same octal format as the backplane and can be clocked into position in the factory or by the end-user.
19
Figure 4-4: VITA 46.0 Equivalent VITA 60.0 Key Nomenclatures
4.4.2 Definitions This section is the same as section 4.4.2 of the VITA 46.0 standard. 4.4.3 Keying Rules This section is the same as section 4.4.3 of the VITA 46.0 standard with the following changes to the rules: Rule 4-8: For the 6U case, if the High Voltage Power Input used by the plug-in module is 48V, the plug-in module voltage keying device that is installed shall be one of two types - either the B position or the C position Rule 4-9: For the 6U case, the preferred angle for the plug-in module voltage keying module for the 48V case is B and this shall be used unless specific system requirements for a user keying range greater than 25 (6U modules) exist. All standard catalog 48V plug-in modules shall use this setting. Rule 4-10: For the 6U case, if the high voltage power input used by the plug-in module is 12V, the plug-in module shall have either the A or the H alignment-key installed. Rule 4-11: For the 6U case, the preferred angle for the plug-in module voltage keying device for the 12V case is H and this should be used unless specific system requirements for a user keying range greater than 25 exist. All standard catalog 12V plug-in modules shall use this setting. Rule 4-12: For the 6U case, if the plug-in module does not use any high voltage power input (Vs1 and Vs2 are no-connects), the plug-in module keying device that is installed shall be without a D-key that will mate with a backplane keying pin positioned at any octal position. Rule 4-13: For the 6U case, the plug-in module voltage keying device of type G shall be reserved for future use. Rule 4-14: To facilitate ease of system integration, standard catalog 6U plug-in modules shall be delivered with keying devices #2 and #3 installed without D-keys, and standard catalog 3U plug-in modules shall be delivered without D-keys in devices #1 and #2. Observation 4-3: Users who wish to apply slot-specific keying can do so in the field or at the assembly stage of the manufacturing process through the use of the D-keys.
20
Observation 4-4: The Alignment-keying device is designed to provide a safety ground path between the plug-in module and the appropriate chassis grounding point. 4.5 Two Level Maintenance This section is the same as section 4.5 of the VITA 46.0 standard. 4.6 Connector Pin Definition P0 This section is the same as section 4.6 of the VITA 46.0 standard. 4.7 Electrical Budgets for Protocol Standards This section is the same as section 4.7 of the VITA 46.0 standard. 4.8 Signal Definition P0 This section is the same as section 4.8 of the VITA 46.0 standard with the exception of the Power paragraph, 4.8.1. The subsections of 4.8.1 and the remainder of section 4.8 are the same as the VITA 46.0 standard. 4.8.1 Power This section is the same as section 4.8 of the VITA 46.0 standard with the following change: Permission 4-2: Plug-in modules may use the appropriate combination of Vs1, Vs2 and Vs3 to accommodate the design requirements. However, to claim conformance to this standard, plug-in modules must be capable of being inserted in a standard keyed location. See VITA 60.0, section 4.4.3.
21
Table 4-1: Power Wafer Current Ratings These current ratings are dependent on several variables, such as: ! Heatsinking, e.g. copper plane thickness and size, connected to power pins. The above ratings are from test data for 1 and 2 ounce copper planes within test plug-in modules and backplane. ! Thermal management, e.g. cooling method for a plug-in module. The above ratings are from test data where cooling was to still ambient air.
!"#$ &' ()*+, -./+, 01,,+23 4.3526 /), 7'80 #+9:+,.31,+ 45;+ ()*+, (<.2+ #=5>?2+;; 52 (<16 .2@ (<.A B)@1<+ C D12>+ 0)::+, E D12>+ 0)::+, F19G+, )/ -./+,; $>,);; -=5>= ()*+, 5; H5;;5:.3+@ 7 -./+,; C -./+,; E -./+, 7 -./+,; C -./+,; E -./+, 01,,+23 $<<)*+@ :+, 0)23.>3 I$J !" !$%&' &(%' (%' !!%&' &" 01,,+23 $<<)*+@ :+, -./+, I$J &" )&%' '' !' &&%' *" 01,,+23 $<<)*+@ :+, 0)22+>3), I$J $" $' '' *' *' *" 4.9 Connector Pin Definition - P1 This section is the same as section 4.9 of the VITA 46.0 standard with the exception of the below rules from section 4.9: Rule 4-53: The connector section used in location P1 shall be loaded with 8 odd and 8 even differential wafers. The common P1 pinout for VITA 60.0 shall be identical to the common P1 pinout for VITA 46.0, Table 4-6. The P1 signal definitions for VITA 60.0 shall be identical to the P1 signal definitions for VITA 46.0, Table 4-7. Rule 4-54: Single-ended pins in P1, Row G. Wafer 1 shall be reserved for future use. The plug-in module shall not connect/route/provide electrical signals to these pins. It is expected that the differential pins will be used for serial fabrics.
22
5 3U Module 5.1 Overview 3U Module This section is the same as section 5.1 of the VITA 46.0 standard. 5.2 Connectors 3U Module The VITA 60.0 3U connector is a monolithic connector incorporating P0, P1 and P2 modular increments into a single entity on a contiguous stiffener assembly. Single-ended and differential wafers can be located in P2. RF and Optical solutions may also be incorporated into the P2 location. Please refer to Table 5-1 for individual part numbers. Table 5-1: 3U VITA 60.0 3U Module Connectors !"##$%&"' )*'& +$,%'-.&-"# +$,%'-.&-"# 0, 1 ulfferenLlal, 2 ulfferenLlal See SecLlon 4.2 3u vl1A 60.0 wlLh ulfferenLlal 2 1
5.3 Keying 3U Module Rule 5-6: Two alignment-keying devices shall be used, located as defined in Section 4 and the Appendices. 5.4 Connector Pin Definition 3U Module P2 5.4.1 Standard Connector P2 Rule 5-7: When a standard connector is used in location P2, it shall be loaded with sixteen wafers. The type of wafers used depends on the protocol specification in use; wafers may be either differential odd and even, or the single-ended type. Rule 5-8: When a standard VITA 60.0 connector is used in location P2, it shall utilize either all differential wafers (alternating odd and even), or all single-ended wafers. 5.4.2 Recommended Location on 3U module for Application-Specific Connector This section is the same as section 5.4.2 of the VITA 46.0 standard. 5.4.2.1 Differential Connector Allocation This section is the same as section 5.4.2.1 of the VITA 46.0 standard.
1 Amphenol Backplane Systems - Part Number VP773-10001 or equivalent 2 Amphenol Backplane Systems Part Number VP773-10002 or equivalent
23
5.4.2.2 Single-ended Connector Allocation This section is the same as section 5.4.2.2 of the VITA 46.0 standard. 6 Module 6.1 Overview This section is the same as section 6.1 of the VITA 46.0 standard. 6.2 Connectors Rule 6-2: VITA 60.0 6U plug-in modules shall utilize one 8-wafer connector section, plus one, two, three, four, five or six 16-wafer connector sections assembled onto a contiguous stiffener assembly that includes three alignment/ keying blocks per Figures 4-1 and 4-2. Rule 6-3: The connectors shall be denoted as P0, P1, P2, P3, P4, P5 and P6. Numbering of the connector sections is shown in Section 4. Rule 6-4: P0 and P1 shall be as defined in Section 4. Rule 6-5: P2 through P4 (and generally P5 and P6) shall utilize 16-wafer connector sections. More detail is given in Section 4. Observation 6-2: A standard differential connector section with 8 odd and 8 even differential wafers has 144 pins; 72 GNDS, 64 differential signals, 8 single-ended signals. A single-ended connector section with 16 wafers has 144 pins, 64 GNDS, 80 single-ended signals.
24
Table 6-1: 6U VITA 60.0 3U Module Connectors 3
3
AMPHENOL PART NUMBER OUTLINE FOR VITA 60.0 VARIATIONS (Standard Connector No. for Module Card Shown) Amphenol Backplane Systems part numbers, or equivalent 6U Configuration Part No. 6U Configuration Part No. 6U Configuration Part No. 6U Configuration Part No. Variant C VP776-10001 Variant L VP776-10009 Variant T VP776-10017 Variant AB VP776-10025 Variant D VP776-10002 Variant M VP776-10010 Variant U VP776-10018 Variant AC VP776-10026 Variant E VP776-10003 Variant N VP776-10011 Variant V VP776-10019 Variant AD VP776-10027 Variant F VP776-10004 Variant O VP776-10012 Variant W VP776-10020 Variant AE VP776-10028 Variant G VP776-10005 Variant P VP776-10013 Variant X VP776-10021 Variant AF VP776-10029 Variant H VP776-10006 Variant Q VP776-10014 Variant Y VP776-10022 Variant AG VP776-10030 Variant J VP776-10007 Variant R VP776-10015 Variant Z VP776-10023 Variant AH VP776-10031 Variant K VP776-10008 Variant S VP776-10016 Variant AA VP776-10024 Variant AI VP776-10032
Configuration P0 P1 P2 P3 P4 P5 P6 Variant C (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Dif f erential Dif f erential Variant D (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Dif f erential Dif f erential Variant E (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Dif f erential Dif f erential Variant F (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Dif f erential Dif f erential Variant G (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Dif f erential Dif f erential Variant H (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Dif f erential Dif f erential Variant J (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Dif f erential Dif f erential Variant K (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Dif f erential Dif f erential Variant L (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Single Ended Dif f erential Variant M (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Single Ended Dif f erential Variant N (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Single Ended Dif f erential Variant O (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Single Ended Dif f erential Variant P (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Single Ended Dif f erential Variant Q (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Single Ended Dif f erential Variant R (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Single Ended Dif f erential Variant S (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Single Ended Dif f erential Variant T (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Dif f erential Single Ended Variant U (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Dif f erential Single Ended Variant V (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Dif f erential Single Ended Variant W (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Dif f erential Single Ended Variant X (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Dif f erential Single Ended Variant Y (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Dif f erential Single Ended Variant Z (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Dif f erential Single Ended Variant AA (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Dif f erential Single Ended Variant AB (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Single Ended Single Ended Variant AC (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Single Ended Single Ended Variant AD (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Single Ended Single Ended Variant AE (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Single Ended Single Ended Variant AF (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Single Ended Single Ended Variant AG (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Single Ended Single Ended Variant AH (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Single Ended Single Ended Variant AI (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Single Ended Single Ended
25
6.3 Alignment and Keying This section is the same as section 6.3 of the VITA 46.0 standard. 6.4 Connector Pin Definition 6.4.1 Connector P2 Rule 6-7: The connector used in location P2 shall be loaded with sixteen wafers. The type of wafers used depends on the protocol specification in use; wafers may be either odd and even differential, or the single-ended type. Rule 6-8: The connector used in location P2 shall utilize either all differential wafers, or all single- ended wafers. 6.4.1.1 Differential Connector Allocation Rule 6-9: When the protocol specification calls for differential wafers in P2, the pins in connector P2 shall be identical to those defined in Table 6-2 of the VITA 46.0 standard. 6.4.1.2 Single-Ended Connector Allocation Rule 6-10: When the protocol specification calls for single-ended wafers in P2, the pins in connector P2 shall be identical to those defined in Table 6-3 of the VITA 46.0 standard. 6.4.2 Connector P3 Rule 6-11: The connector used in location P3 shall be loaded with sixteen wafers. The type of wafers used depends on the protocol specification in use; wafers may be either differential, or the single-ended type. Rule 6-12: The connector shall utilize all odd and even differential wafers, or all single-ended wafers. 6.4.2.1 Differential Connector Allocation Rule 6-13: When the protocol specification calls for differential wafers in P3, the pins in connector P3 shall be identical to those defined in Table 6-4 of the VITA 46.0 standard. 6.4.2.2 Single-ended Connector Allocation Rule 6-14: When the protocol specification calls for single-ended wafers in P3, the pins in connector P3 shall be identical to those defined in Table 6.5 of the VITA 46.0 standard.
26
6.4.3 Connector P4 Rule 6-15: The connector used in location P4 shall be loaded with sixteen wafers. The type of wafers used depends on the protocol specification in use; wafers may be either odd and even differential, or the single-ended type. Rule 6-16: The connector shall utilize all differential wafers, or all single-ended wafers. 6.4.3.1 Differential Connector Allocation Rule 6-17: When the protocol specification calls for differential wafers in P4, the pins in connector P4 shall be identical to those defined in Table 6.6 of the VITA 46.0 standard. 6.4.3.2 Single-Ended Connector Allocation Rule 6-18: When the protocol specification calls for single-ended wafers in P4, the pins in connector P4 shall be identical to those defined in Table 6.7 of the VITA 46.0 standard. 6.4.4 Connector P5 Rule 6-19: The connector used in location P5 shall be loaded with sixteen wafers. The type of wafers used depends on the protocol specification in use; wafers may be either odd and even differential, or the single-ended type. Rule 6-20: The connector shall utilize all differential wafers, or all single-ended wafers. 6.4.4.1 Differential Connector Allocation Rule 6-21: When the protocol specification calls for differential wafers in P5, the pins in connector P5 shall be identical to those defined in Table 6.8 of the VITA 46.0 standard. 6.4.4.2 Single-Ended Connector Allocation Rule 6-22: When the protocol specification calls for single-ended wafers in P5, the pins in connector P5 shall be identical to those defined in Table 6.9 of the VITA 46.0 standard. 6.4.5 Connector P6 Rule 6-23: The connector used in location P6 shall be loaded with sixteen wafers.
The type of wafers used depends on the protocol specification in use; wafers may be either odd and even differential, or the single-ended type. Rule 6-24: The connector shall utilize all differential wafers, or all single-ended wafers.
27
6.4.5.1 Differential Connector Allocation Rule 6-25: When the protocol specification calls for differential wafers in P6, the pins in connector P6 shall be identical to those defined in Table 6-10 of the VITA 46.0 standard. 6.4.5.2 Single-ended Connector Allocation Rule 6-26: When the protocol specification calls for single-ended wafers in P6, the pins in connector P6 shall be identical to those defined in Table 6-11 of the VITA 46.0 standard. 6.4.6 Locations on 6U module for User Defined Application-Specific Connectors This section is the same as section 6.4.6 of the VITA 46.0 standard. 7 Backplanes This section is the same as section 7 of the VITA 46.0 standard with the following exceptions: Connector Selection paragraph, 7.1.3; Backplane Keying paragraph, 7.8; Preventing Damage from Backwards Plug-In Module Insertion, 7.9.
7.1.3 Connector Selection This section is the same as section 7.1.3 of the VITA 46.0 standard with the following updated observation. Observation 7-3: The backplane connectors do differentiate among power, single-ended and differential wafers on the mating plug-in module and must be loaded into the individual backplane modules accordingly. User defined connectors must be compatible with the selected plug-in module connectors. As defined in Table 7-1.
28
Table 7-1: Backplane Connector Cross-reference 4
4
AMPHENOL PART NUMBER OUTLINE FOR VITA 60.0 VARIATIONS (Standard Connector No. for Backplane Shown) Amphenol Backplane Systems part numbers, or equivalent 6U Configuration Part No. 6U Configuration Part No. 6U Configuration Part No. 6U Configuration Part No. Variant C VJ776-10001 Variant L VJ776-10009 Variant T VJ776-10017 Variant AB VJ776-10025 Variant D VJ776-10002 Variant M VJ776-10010 Variant U VJ776-10018 Variant AC VJ776-10026 Variant E VJ776-10003 Variant N VJ776-10011 Variant V VJ776-10019 Variant AD VJ776-10027 Variant F VJ776-10004 Variant O VJ776-10012 Variant W VJ776-10020 Variant AE VJ776-10028 Variant G VJ776-10005 Variant P VJ776-10013 Variant X VJ776-10021 Variant AF VJ776-10029 Variant H VJ776-10006 Variant Q VJ776-10014 Variant Y VJ776-10022 Variant AG VJ776-10030 Variant J VJ776-10007 Variant R VJ776-10015 Variant Z VJ776-10023 Variant AH VJ776-10031 Variant K VJ776-10008 Variant S VJ776-10016 Variant AA VJ776-10024 Variant AI VJ776-10032
Configuration J0 J1 J2 J3 J4 J5 J6 Variant C (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Dif f erential Dif f erential Variant D (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Dif f erential Dif f erential Variant E (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Dif f erential Dif f erential Variant F (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Dif f erential Dif f erential Variant G (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Dif f erential Dif f erential Variant H (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Dif f erential Dif f erential Variant J (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Dif f erential Dif f erential Variant K (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Dif f erential Dif f erential Variant L (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Single Ended Dif f erential Variant M (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Single Ended Dif f erential Variant N (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Single Ended Dif f erential Variant O (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Single Ended Dif f erential Variant P (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Single Ended Dif f erential Variant Q (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Single Ended Dif f erential Variant R (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Single Ended Dif f erential Variant S (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Single Ended Dif f erential Variant T (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Dif f erential Single Ended Variant U (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Dif f erential Single Ended Variant V (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Dif f erential Single Ended Variant W (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Dif f erential Single Ended Variant X (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Dif f erential Single Ended Variant Y (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Dif f erential Single Ended Variant Z (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Dif f erential Single Ended Variant AA (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Dif f erential Single Ended Variant AB (6U) Baseline Dif f erential Dif f erential Dif f erential Dif f erential Single Ended Single Ended Variant AC (6U) Baseline Dif f erential Single Ended Dif f erential Dif f erential Single Ended Single Ended Variant AD (6U) Baseline Dif f erential Dif f erential Single Ended Dif f erential Single Ended Single Ended Variant AE (6U) Baseline Dif f erential Single Ended Single Ended Dif f erential Single Ended Single Ended Variant AF (6U) Baseline Dif f erential Dif f erential Dif f erential Single Ended Single Ended Single Ended Variant AG (6U) Baseline Dif f erential Single Ended Dif f erential Single Ended Single Ended Single Ended Variant AH (6U) Baseline Dif f erential Dif f erential Single Ended Single Ended Single Ended Single Ended Variant AI (6U) Baseline Dif f erential Single Ended Single Ended Single Ended Single Ended Single Ended
29
7.8 Backplane Keying Refer to section 4.4 for background information and definitions that apply to VITA 60.0 keying for both plug-in modules and backplanes. 7.9 Preventing Damage from Backwards Plug-in Module Insertion This section is the same as section 7.9 of the VITA 46.0 standard with exception of Observation 7-23. For 6U plug-in modules, the short center alignment keying pin in VITA 60.0 will not result in damage to the P4 connector resulting from a backwards installed plug-in module.
30
Appendix A Plug-in Module Assembly Drawings Figure A-1 3U Air Cooled Module Layout
31
Figure A-2 3U Conduction Cooled Layout
32
Figure A-3 6U Air Cooled Layout
33
Figure A-4 6U Conduction Cooled Layout
34
Figure A-5 3U Conduction Cooled Module End View
35
Figure A-6 6U Conduction Cooled Module End View
36
Figure A-7 3U Chassis Side Wall
37
Figure A-8 Conduction Cooled Module Side View
38
Appendix B Backplane Printed Circuit Board Fabrication Drawings Figure B-1 3U Air Cooled Backplane
39
Figure B-2 6U Air Cooled Backplane
40
Figure B-3 3U Conduction Cooled Backplane, Plan View
41
Figure B-4 6U Conduction Cooled Backplane, Plan View
42
Figure B-5 6U Backplane, End View
43
Figure B-6 3U Backplane, End View
44
Appendix C Plug-in Module Printed Circuit Board Fabrication Drawings Figure C-1 3U PCB Fabrication Drawing (viewed from Primary Side)
45
Figure C-2 6U PCB Fabrication Drawing (viewed from Primary Side)
Proceedings of the Metallurgical Society of the Canadian Institute of Mining and Metallurgy: Proceedings of the International Symposium on Fracture Mechanics, Winnipeg, Canada, August 23-26, 1987