Sie sind auf Seite 1von 1

Rear Panel

Features
www.ares.com.vn
1KVA~10KVA
220V
AR900II RT
Online High Frequency UPS
www.ares.com.vn
O
n
l
i
n
e

H
F

U
P
S
8
8
SNMP/USB/AS400 (Optional) 8
Outlet
FAN
RS232
Overcurrent Protection
AC Input
Modem/Tel/Fax
DC Input
Dimension(mm) W*D*H
Packing Dimension(mm) W*D*H
Net/Gross Weight(kg)
Standard
Model
Long
Time
Model 6.0/7.0 12.0/13.5
Dimension(mm)
W*D*H
Packing Dimension(mm)
W*D*H
Net/Gross Weight(kg)
24V
2*9Ah
48V
4*9Ah
72V
6*9Ah
192V
16*9Ah
<50dB (1m) <55dB (1m)
1A
8 hours recover to 90% capacity
Beep/4s
Beep/1s
Beep Twice/1s
Long Beep
o
20~90% RH @ 0~40 C(non-condensing)
Supports Windows 98/2000/2003/XP/Vista/2008/7/8
Power management from SNMP manager and web browser
6A 1A/3A/5A/8A
Standard Model
Long Time Model
Charge Current
All specifications subject to change without notice.
made specifications are acceptable-Custom
Specifications
AR901IIRT
1KVA/900W
AR902IIRT
2KVA/1800W
AR903IIRT
3KVA/2700W
105%-150%:Transfer to bypass after 30s;
>150%: Transfer to bypass after 300ms
6KVA/5400W 10KVA/9000W
AR906IIRT AR9010IIRT MODEL
Capacity
INPUT
Rated Voltage
Voltage Range
Frequency
Power Factor
Bypass Voltage Range
OUTPUT
Voltage Regulation
Frequency
Waveform
Crest Factor
Harmonic Distortion
EFFICIENCY
AC Mode
Battery Mode
ECO Mode
BATTERY
DC Voltage
Inbuilt Battery of Standard Model
Typical Recharge Time
ALARM
Utility Failure
Battery Low
Overload
UPS Fault
ENVIRONMENT
Humidity
Noise Level
MANAGEMENT
Standard RS-232 ,Optional USB
Optional SNMP
PHYSICAL
208V/210V/220V/230V/240VAC
Half load (115-295)5VAC ; Full load (145-295)5VAC
45-55Hz0.5%Hz or 55-65Hz0.5%Hz (Auto Sensing)
>=0.98
208V/210V/220V/230V/240VAC Setting available via LCD
1%
Synchronized with utility on AC mode;50/600.2Hz on battery mode
Pure sine wave
3:1
<3%(Linear load); <5%(Non-linear load)
105%-125%:Transfer to bypass after 3mins;
125%-150%: Transfer to bypass after 30s;
>150%: Transfer to bypass after 100ms
Overload Capability
Transfer Time
Voltage
Rated output voltage-34V- Rated output voltage+32V
440 468 88
580x590x200
x x 440 565 132
535x660x215
x x
13.0/14.5 19.0/21.5
440 468 88
580x590x170
x x
12.0/13.5 28.0/29.5 33.0/34.5 19.0/21.5(UPS),52.0/54.5(BAT)
440 565 132(UPS)
440x565x132(BAT)
535x660x215(UPS)
546x676x266(BAT)
x x
Mark: S means standard model, H means long backup time model.
Rack/Tower design
High frequency and true double-conversion
DSP digital control technology
Input power factor correction (PFC)
Wide input voltage range (110V-300V)
Output power factor 0.9/0.8
Code start
Frequency adaptive
ECO mode operation for energy saving
Selectable output voltage via LCD
Output bypass settable for 1,2,3KVA via LCD
Selectable battery low voltage via LCD
Automatically diagnose when starts
Advanced battery management (ABM)
Short circuit and overload protection
Automatically charging battery at UPS off mode
Fan speed auto control when load varies
Standard RS232 communication port and RJ45 protection
Optional USB/SNMP communication port
Optional emergency power off (EPO)
Optional extension battery bank
440 690 88
530x825x170
x x
AC mode to battery mode :0ms
Inverter model to bypass mode:4ms(Typical)
AC mode to battery mode :0ms
Inverter model to bypass mode:0ms
1-3KVA
6-10KVA
Same as input frequency
50/60 0.2Hz
>=94%
Same as input frequency
50/60 0.2Hz
Non ECO
R
YOUR RELIABLE UPS PARTNET

Das könnte Ihnen auch gefallen