DEAD LEGS BIOCIDE TREATMENT

Equipment/PID Location Line number


valve
TAG
Remarks
Done
Yes/no
DS300/ 1950 LV3002 by pass 6"PW400028 1 NO
FE3000 by pass 8"GH300018 2 NO
Drain header to closed drain 4"DF350001 3 Pressure balanced by LG drain NO
Oil outlet to closed drain 1"DF350288 4 NO
DS301/1951 Link water/oil outlet 6"GH300038 5 Yes
Sampling oil outlet 18"GH300040 6 Yes
Drain header to closed drain 4"DF350002 7 Yes
EC313/1953 (01/02) DS301 outlet to closed drain C523A-P 8 Yes
Outlet EC313A to closed drain 2"DF350211 9 Yes
1" EC313A body drain cold side 1" 10 Valve handle missing NO
Outlet EC313B to closed drain 2"DF350213 11 NO
1" EC313B body drain cold side 1" 12 NO
Outlet EC313C to closed drain 2"DF350215 13 NO
1" EC313C body drain cold side 1" 14 NO
Outlet EC313D to closed drain 2"DF350217 15 NO
1" EC313D body drain cold side 1" 16 NO
EC313 A/B/C/D by bass cold side 16"GH300096 17 NO
DS302/1953 (02/02) Link water/oil outlet 3"GH300071 18 Yes
Drain header to closed drain 4"GH300075 19 Pressure balanced by LG drain Yes
GX310/1954 GX310A suction strainer drain 2"DF350080 20 If pump runs Yes
GX310A discharge drain 2"DF350077 21 If pump runs Yes
GX310A suction vent 1"GH310074 22 If pump runs Yes
GX310B suction strainer drain 2"DF350080 23 If pump runs NO
GX310B discharge drain 2" 24 If pump runs NO
GX310B suction vent 1"GH310075 25 If pump runs NO
DS320A/1955(01/02) PDV3201A by pass 2" by pass 26 NO
1"Drain of DS320A inlet 1"DF350292 27 NO
3" drain of outlet water 4"PW320028 28 Spaded NO
GX320 discharge to oily water package 4"PW400006 29 Yes
DS320B/1955(02/02) PDV3201B by pass 2" by pass 30 Yes
3" drain of outlet water 4"PW320016 31 Yes
EC321 by pass 4"PW320028 32 Not in service NO
Oily water U/S EC321 to open Drain 2"DO360079 33 NO
Oily water tosand jet DS400 3"PW400058 34 NO
Oily water to sample box 2"PW400042 35 Spaded NO
1"Drain of DS320B inlet 3/4" 36 line chocked NO
DS401( Vendor PID) Drain D/S LV4007 3/4" 37 NO
Skimmed oil pipe GX400A discharge drain to closed drain 1"DF350244 38 line chocked NO
GX400B discharge drain to closed drain 1"DF350245 39 NO
DA350/1866 GX350A recirculation line 2"DF350222 40 Yes
GX350B recirculation line 2"DF350223 41 Yes
DEAD LEG WHILE DS 320A BY PASS
GX320: pump stopped
DS320A/1955(01/02) Mini flow GX320 2"PW320025
Start pump set FIC3204 to get flow
during biocide treatment Yes
GX320 unavailable for long time
DS320A/1955(01/02) GX320A suction line 6"PW320016 Drain by 3/4"drain valve Yes
GX320A discharge line 4"PW320018 Drain by 3/4"drain valve Yes
GX320B suction line 6"PW320017 Drain by 3/4"drain valve NO
GX320B discharge line 4"PW320019 Drain by 3/4"drain valve NO
Instruction: Flush 2 hours after the beginning of biocide treatment
Location Pump Yes / No
DS300 GX827-3A Yes
DS301 GX827-2A Yes
DS302 GX827-1A NO
PSV3130A (or B) GX827-1A Yes
DA350 GXTemporary Yes
Suction
GX722/721A/B GX821-2A/2B NO
\\vboxsrv\conversion_tmp\scratch_5\[246839683.xls.ms_office.xls]Sheet1
Injection point of Biocide Treatment