Short Reference Guide
for SIMODRIVE 611 analog System
Feed module
Rectifier module
DIL switch S1 (supply infeed):
ON: OFF:
1
2
3
4 V
supply
=480V +6% / 10% Refer to S1.1
1) Only for I/R module
0.5
2
3
4
5
6
7
8
9
10x DIL switch S2: = ON = OFF
1 Direction of rotation reversal
Current limit I
max
/I
limit
as a %
61 50 46 41 39 36 34 30 29 26 24 23
1 2 2.5 4 4.5 5.5 6 6.5 7.5 8 9.5 11
continuous possible current: I
rated
=25 A
brief possible current: I
limit
=50 A
contacts: 2 = ON, 3 = ON 61 %
selected current limits: I
max
=30.5 A
11.5
Gain of the current controller Kp(I)
10
OFF: closedloop speed controlled operation
Example:Feed module 25 A/50 A
DIL switch (feed module):
Gearbox stage
Gearbox stage
Faults
1) As supplied
after power ON
Operating display inactive
min. two phases missing (NE module)
min. two input fuses have failed
(NE module)
defective electronics power supply in the NE module
equipment bus connection, MSD module NE mod-
ule not inserted or defective
defective MSD module
defective EPROM/FEPROM
firmware not loaded
Controller
enable
Motor rotates max. 30 RPM at n
set
> 30 RPM or motor oscil-
lates for n
set
< 30 RPM
incorrect motor rotating field, as the feeder cable is
interchanged (interchange 2 phases)
HPC axis 30
Slip monitoring 32
FP04 No valid zero mark
F61 Max. motor frequency exceeded
FP03 Zero mark offset > encoder pulse number
F16 Illegal power module code number
excessive motor encoder pulse number entered
Motor stationary for a speed setpoint not equal to zero
oscillation function has been selected
Short Reference Guide
for SIMODRIVE 611 analog System
Main spindle module
+
P
+
+
P
+
P
Operator and display elements Operating display Connections
Inactive Relay func-
tion
Operating
mode
Equipment
status
Gearbox
stage
Operating
mode
Parameter value
Parameter number
Subparameter number
PE2
Motor terminals
X432
Spindle encoder, Bero or
encoder output at NC
PE1 W2 V2 U2
Rating plate
Product release
P 600
M 600
DC link
X151 Equipment bus X351
X412 Motor enco-
der RON
350
LCD display
+ P -
X411
RS232C
interface
Inputs
X431
X421
Test sockets
n
set2
n
set1
M
M
X451
DAU 2
DAU 1
X441
2nd M
d
limit value
1)
IF
RF
HSS
n
act
< n
min
1)
n
act
< n
x
1)
Outputs
G. box stage, bit 2
1)
G. box stage, bit 1
1)
Enable voltage
663
A91
A92
56
14
24
8
65
81
E1
E2
E3
E4
E5
E6
E7
E8
E9
289
A11
A21
A31
A41
A51
A61
672
673
674
AS1
AS2
T
H
= 0
1)
RESET
1)
M19
1)
M
d
controlled
1)
Oscillation
1)
Motor overtemperature
1)
Conv. overtemperature
1)
Ready/fault
Signaling contact
Start inhibit
n
act
= n
set
1)
M
d
< M
dx
1)
Startup information
Reinitialize
drive converter
(if necessary)
D Set P051 to 4H
D Set P097 to 0H
D Set P052 to 1H and wait until P052
resets itself to 0H
D Powerdown the unit and approx. 2 s after the
display has gone dark, powerup the unit
again:
P095 must be redisplayed
D Initialize
Replace firmware
(if required)
D Save the setting data (parameters)
D Replace the firmware using the startup
program
D Initialize with the pulses and controller
inhibited
D The saved setting data are reloaded
D Save the setting data in the drivemachine
data memory
Number
Display
range
(P099)
Firmware release
Board ID
Firmware version and module expansion
Description
0.00 ... 99.00
(P150)
Startup possi-
bilities
using the
D Operator control and display element
D RS232C interface with an
IBM/ATcompatible computer
1) Freelyprogrammable terminals and relay functions when supplied
P
P
+
P
P
+ >> <<
<< >>
> <
<
>
Gearbox
stage 1
Gearbox
stage 2
Gearbox
stage 3
Gearbox
stage 4
Gearbox
stage 5
Gearbox
stage 6
Gearbox
stage 7
Gearbox
stage 8
Star
circuit
2)
Delta
circuit
2)
Digit.
filter
2)
Position 1
3)
Pos. 2
3)
Pos. 3
3)
Pos. 4
3)
Incr. Pos.
3)
Enable mis-
sing at NE
m.
Axisspecific
pulse enable
missing
Contr.
enable
missing
RFG ena-
ble mis-
sing
Setpoint
enable
missing
Motoring
4)
Regenerating
4)
Wait sta-
tus
Cl.loop
speed
contr. op.
Torquecon-
trolled op.
M19
Positioniong
C axis
Curr./Hzcontr.op.
T. A11
P241
T. A21
P242
T. A31
P243
T. A41
P244
T. A51
P245
T. A61
P246
T. 672/674
P053
DAU 4 DAU 3
Version coding:
F00H Basic version
200H With additional input for spindle encoder
300H With output pulse encoder signals for external use
M
X1
IR
X2
2
)
D
i
s
p
l
a
y
i
n
P
1
0
0
:
O
n
l
y
f
o
r
t
h
e
s
t
a
r
/
d
e
l
t
a
m
o
d
e
3
)
D
i
s
p
l
a
y
i
n
P
1
0
0
:
O
n
l
y
f
o
r
t
h
e
s
p
i
n
d
l
e
p
o
s
i
t
i
o
n
i
n
g
m
o
d
e
4
)
D
i
s
p
l
a
y
o
f
t
h
e
t
o
r
q
u
e
d
i
r
e
c
t
i
o
n
w
i
t
h
t
h
e
m
o
t
o
r
e
n
a
b
l
e
d
jl
HPC axis
0.5 ms
( 0.6 ms)
Torquecontr.
op. w/slip monit.
9
F60 Error for the automatic setting routine
Fault, D/A conversion
14
Drive converter interfaces Fault analysis
Terminal function
Fct.No.
Input
terminal
1)
2nd torque limit 1 E1 (P081)
Oscillation 2
Reset fault memory (R)
3 E3 (P083)
(fault acknowledgement)
Rampup time=0 7 E2 (P082)
Fault acknowledgement
Parameter key The parameter key is pressed with controller inhibit
present. If the fault/error can be acknowledged, the
system returns to the operator program.
Remote ack-
nowledgment
One of the following terminals is energized with
the controller inhibited:
terminal R at the NE or monitoring module
terminal Reset fault memory at the MSD module
Poweringdown Powerdown the unit and approx. 2 s after the dis-
play goes dark, powerup again
Changingover into
the operator inter-
face
After pressing the key, the operator
program is returned to for approx. 1 minute; howe-
ver, the fault/error is not acknowledged.
Clockwise/counterclockwise 12
Rampfunction generator 2 13
Increase setpoint 14
Decrease setpoint 15
Setpoint enable 16
Gearbox stage 9 E7 (P087)
Relay function
Fct.No.
Relay
output
1)
Rampup completed 2 A61 (P246)
|M
d
| < M
dx
3 A21 (P242)
|n
act
| < n
min
1 A31 (P243)
|n
act
| < n
x
4 A41 (P244)
I
2
t prealarm 5 A51 (P245)
Drive converter overtemp. prealarm 6
Variable relay function 1 7
Variable relay function 2 8
Motor 2 active 12
Motor 3 active 13
Motor 4 active
Motor 1 active
Fault
message
Fault
F07 Data save on FEPROM not successful
F08 Irretrievable data loss
F11 Frequency setpoint > max. frequency
F13 Field controller is at its max
F15 Overtemperature, drive converter
F17 I
0
motor > I
rated
power module
bit 1 10 E8 (P088)
bit 2 11 E9 (P089)
bit 0
Faults
after power ON Operating display inactive
min. two phases missing (NE module)
min. two input fuses have blown (NE module)
defective electronics power supply in the
NE module
Equipment bus connection, IM module ! NE
module not inserted or defective
defective IM module
defectiveEPROM/FEPROM
firmware not loaded
Controller enable Motor rotates counterclockwise although the IM
module outputs a clockwise rot. field or vice versa
incorrect motor rotating field, as the feeder
cable is interchanged, (interch. 2 ph. conn.)
F05 Motor current = 0
11
Fixed setpoint selection 17 E4 (P084)
bit 1 18 E5 (P085)
bit 2 19 E6 (P086)
bit 0
Motor selection 20
bit 1 21
bit 0
1) As supplied
bit 3 24
20 A11 (P241) n
act
=n
set
F51 Parameterizing error: Rated torque too high
F52 Parameterizing error: Torque constant illegal
Short Reference Guide
for SIMODRIVE 611 analog System
Induction motor module
+
P
+
+
P
+
P
Operator and display elements
Operating display Connections
Motor
number
Relay func-
tion
Operating mode Equipment
status
Gearbox
stages
Setpoint
source
Parameter value
Parameter number
Subparameter number
PE2
Motor terminals
X432
PE1 W2 V2 U2
Rating plate
Product release
P 600
M 600
DC link
X151 Equipment bus X351
X412
LCD display
+ P
X411 RS232C
interface
Inputs
X431
X421
Test sockets
n
1
M
M
X451
X441
2nd M
d
limit value
1)
IF
RF
|n
act
| < n
min
1)
|n
act
| < n
x
1)
Outputs
Enable voltage
663
A91
A92
56
14
24
8
65
81
E1
E2
E3
E4
E5
E6
E7
E8
E9
9
289
A11
A21
A31
A41
A51
A61
672
673
674
AS1
AS2
T
H
= 0
1)
RESET
1)
Ready/fault
Signaling contact
Start inhibit
n
act
= n
set
1)
|M
d
| < M
dx
1)
Startup information
Reinitialize
drive converter
(if necessary)
D Set P051 to 4H
D Set P097 to 0H
D Set P052 to 1H and wait until P052
resets itself to 0H
D Powerdown the unit and approx. 2 s after the
display has gone dark, powerup the unit
again:
P095 must be redisplayed
D Initialize
Replace firmware
(if required)
D Save the setting data (parameters)
D Replace the firmware using the startup
program
D Initialize with the pulses and controller
inhibited
D The saved setting data is reloaded
D Save the setting data in the drivemachine
data memory
Number
Display
range
(P099)
Firmware release
Firmware version and module expansion
Description
0.00 ... 99.00
Startup possi-
bilities
using
D Operator control and display elements
D RS232C interface with an
IBM/ATcompatible computer
1) Freelyprogrammable terminals and relay functions as supplied
P
P
+
P
P
+ >> <<
<< >>
> <
<
>
Gearbox
stage 1
Gearbox
stage 2
Gearbox
stage 3
Gearbox
stage 4
Gearbox
stage 5
Gearbox
stage 6
Gearbox
stage 7
Gearbox
stage 8
Analog set-
point and fi-
xed setpoint
Setpoint 0
Fixed setpo-
ints 1 to 7
Mot. pot.
Oscillation
generator
Aut. optimi-
zation
Enable mis-
sing at NE
m.
Axisspecific
pulse enable
missing
Contr.
enable
missing
RFG ena-
ble mis-
sing
Setpoint
enable
missing
Motoring
1)
Regenerating
1)
Wait status
Openloop
speed con-
trolled or
speedcon-
trolled
operation
T. A11
P241
T. A21
P242
T. A31
P243
T. A41
P244
T. A51
P245
T. A61
P246
T. 672/674
P053
DAU 4 DAU 3
M
X1
IR
X2
Motor 1
Motor 2
Motor 3
Motor 4
Analog
setpoint
2) Function not possible for Order No. [MLFB] 6SN11220BA110AA0
n
2
2)
DAU 2
2)
DAU 1
2)
HSS
Fixed setpoint, bit 2
1)
Gearbox stage, bit 2
1)
Gearbox stage, bit 1
1)
Fixed setpoint, bit 0
1)
Fixed setpoint, bit 1
1)
Gearbox stage, bit 0
1)
I
2
t prealarm
1)
Rampup completed
1)
Mess., center contact
1)
Torque direction display
with the motor enabled
Fixed setpo-
ints 8 to 15
3) Only for Order No. [MLFB] 6SN11220BA110AA1, otherwise assignment is
not permissible
Input
BERO
3)
Input
temperature
sensor motor
3)