Sie sind auf Seite 1von 3

Title: Plant and Equipment Noise Measurement Record Form Date Published: 03/06/2013 Page 1 of 2

ID: 329574 Version: 1


Project Management System / N2021 - Uncontrolled Document when Printed
ETTT Alliance ABN 67425839697
Plant and Equipment Noise Measurement Record Form
1 Purpose and Scope
The Construction Environmental Management Plan (CEMP) will require the Project team to
undertake plant and equipment noise monitoring to confirm the predicted impacts from the
various pieces of equipment.
The monitoring of the noise levels will be conducted in accordance with the relevant
standard as defined in the Noise and Vibration Sub-Plan. Each noise monitoring session will
be recorded on the Plant and Equipment Noise Measurement Record Form by the
Environmental Coordinator, Acoustic Consultant or Environmental Manager.
2 Workflow Diagram







3 Process
The Environmental Coordinator to identify the predicted noise levels and noise goals
for the particular piece of equipment
The Environmental Coordinator is to identify suitable monitoring location and conduct
monitoring in accordance with the relevant standard.
Refer to associated knowledge for guidance on how to perform the monitoring.
Monitoring data is to be captured on the Plant and Equipment Noise Measurement Record
Form
4 Deliverables
Completed Plant and Equipment Noise Measurement Record Form
5 Definitions
Term Definition
Text Text


Title: Plant and Equipment Noise Measurement Record Form Date Published: 03/06/2013 Page 2 of 2
ID: 329574 Version: 1
Project Management System / N2021 - Uncontrolled Document when Printed
ETTT Alliance ABN 67425839697
Text Text

6 Related Tools
Plant and Equipment Noise Measurement Record Form
7 Related Knowledge
Plant and Equipment Noise Monitoring Australian Standard Knowledge
8 Process Maps
No Process Maps
9 Associated Processes
No Associated Processes
Plant / Equipment Noise Measurement Record Sheet
N2021 - ETTT
Machinery under test: (e.g. excavator)
Machine manufactuer (e.g. CAT) Date of test
Model/ Rego No. ID Person doing test
Power rating (kW) Speed (rpm) Machine length (m)
Acoustic environment
Site surface: (tick which applies)
Distance to nearest reflective surface (m) from centre of machine
Air temperature Wind speed (m/s)
Instrumentation
SLM Make Model Calibration date
Calibrator Make Model Calibration date
Acoustical data
Fill in the green squares only. The yellow squares will be automatically calculated.
Measurement distance (hemisphere radius, r) (from centerpoint of machine, see below)
Hemisphere surface area, S m
2
L
Aeq
L
A10
L
Aeq
L
A10
L
Aeq
L
A10
L
Aeq
L
A10
L
Aeq
L
A10
1
2
3
4
5
6
Background (measure one location without equipment operating)
Average (all locations)
Note: positions 5 and 6 should only be measured where practical.
(tick which applies)
Average SPL SWL
>4 m
Machine length
16 m
Results dB(A)
1 2 3
<1.5 m
1.5 m - 4 m 10 m
4 m
Hemisphere radius
Measurement
location
(see figure)
F
R
O
N
T

R
E
A
R

1 2
3
4
5
6

=

=
N
i
Ti Aeq T Aeq
L
N
L
1
,
1 . 0
,
10
1
log 10
( )
o
T Aeq WA
S
S
K L L log 10
,
+ =