Sie sind auf Seite 1von 44

Comprehensive range

of pipes, fittings and


couplings for waste
water and rainwater
drainage within
buildings.
Cast I ron Drai nage Syst ems
SAINT-GOBAIN
2
The Pipe Division belongs to Construction Products
activity and acts in both new construction and
renovation sectors.
The SAINT-GOBAIN Group and Habitat strategy
Saint-Gobain, the world leader in the habitat
and construction markets, designs, manufactures
and distributes building materials, providing
innovative solutions to meet growing demand in
emerging economies, for energy efficiency and
for environmental protection.
This innovation-driven group is continuously
designing solutions to build more comfortable,
cost-efficient and sustainable construction projects
worldwide. The market leader in all its businesses,
SAINT-GOBAIN is divided into four activities:
Construction Products, Innovative Materials,
Building Distribution and Packaging which are
either European or world leader.
Choose PAM GLOBAL for cast iron soil and drain systems
3
PAM-GLOBAL
Leading brand
for cast iron drainage
pipes and fittings.
PAM-GLOBAL

S is worldwide
synonymous of socketless,
cast-iron drainage systems.
The PAM-GLOBAL

pipe
systems have been
manufactured over the last 25
years, in France
at SAINT-GOBAIN PAM
factory.
From SML to PAM-GLOBAL

The Pipe Activity in figures:


Turnover: 2.2 billion
More than 12000 employees
and 30 plants throughout the
world.
The Pipe Division of the SAINT-GOBAIN
Group is world leading manufacturer and
export leader of ductile iron and cast iron
complete technical solutions.
The Pipe Division manufactures and sells:
- complete pipe systems for water supply
(including valves and hydrants) and sewage
applications,
- a comprehensive range of municipal
castings: manhole covers, gully gratings,
access covers & surface boxes,
- complete pipe systems for waste water
and rainwater drainage systems for
buildings.
The Pipe Division
SAINT-GOBAIN PAM
Cast Iron Pipe Systems
PAM-GLOBAL

S = Drainage systems for buildings


PAM-GLOBAL

Couplings = Couplings to connect the pipe system elements


EPAMS

= Syphonic roof drainage system


PAM-GLOBAL

Soil and Drain


4
PAM-GLOBAL

Cast Iron Pipe Systems


Suitable for
every site condition
Fit for every job configuration,
PAM-GLOBAL

drainage systems
provide a wide modular range of
products.
The large number of product
references helps meeting all drainage
configurations and coping with most
installation constraints.
PAM-GLOBAL

cast iron drainage


spigot systems specification
The pipes are manufactured in a plant
complying with ISO 9001 quality management
and using the De Lavaud spinning process.
The material of the system is made of cast iron
according to EN 1561.
The tensile strength on samples is 300 MPa,
ring crush strength in average on DN 100 pipe
is 450 MPa and Brinnell surface hardness is 220
HB degrees in average, which altogether indicate
greater resistance to impacts, easier machining
and cutting onsite.
The spigot pipes and fittings, their couplings
and accessories comply with EN 877 standard
and RAL-GZ 698 special quality mark with specific
testing requirements. The rubber gaskets of the
coupling comply with EN 681-1.
Marking: The brand logo, the reference to the
standard and to the quality marks, the diameter
in DN, and the manufacturing date are marked
on the products as required in EN 877.
The inner coating of the pipes is made of epoxy-
resin 130m and the external coating is a primer
acrylic paint 40m.
According to the standard requirement, the internal
coatings can withstand hot water at 95C for 24
hours and withstand fluids between pH 2-12 for
30 days, without loosing their properties.
The fittings are mostly coated through a
cataphoresis (KTL) process.
The drainage system belongs to the A1 Class
f or Bui l di ng Mat eri al accordi ng t o
DIN 4102 in Germany and is non combustible.
It is CE marked on EN 877, and after tests in a
third party accredited laboratory, is ranking
A2-s1, d0, for the complete system.
The thermal expansion coefficient of cast iron
is only 0.0105 mm/m.K and similar to that of
steel and concrete; there is no need for expansion
joints.
The noise insulation properties are complying
with DIN 4109.
Cast iron is 100% recyclable and environment
friendly.
The manufacturing plant is certified ISO 14001.
5
Benefits of PAM-GLOBAL

New lining for pipes for


optimised properties
HPS 2000
Corrosion protection of
fittings through KTL
cataphoresis coating
(inside and outside)
Strictly compatible fitting
systems in the very highest
quality
High durability far beyond
the requirements specified
in EN 877
High abrasion resistance
with a smooth surface for
excellent flow properties
Robust, dimension stable
and shock resistant
High acoustic
performance,
progressive sound
dampening according to
DIN 4109 (and VDI 4100)
Preventative fire
protection. PAM-
GLOBAL

pipes and
fittings are
noncombustible in
keeping with DIN
4102.
Insensitive to heat and
cold, very low thermal
expansion (0.0105
mm/m K), similar to that
of concrete so that their
relative movement
will not cause any
problem.
Primer coated in the
works, permanent
adhesion and attractive
appearance due to special
external finishing coats by
the works (e.g. with bridge
structures)
100% recyclable to
eliminate all waste
disposal problems
Resources are not wasted
as 95% of the material
used to produce PAM-
GLOBAL

S pipes consists
of scrap metal
PAM-GLOBAL

About Us
6
Located in Cologne - Germany,
SAINT-GOBAIN HES operates
within SAINT-GOBAIN
Construction Products Activity.
Part of SAINT-GOBAIN
PAM - one of the world largest
cast iron drainage systems
manufacturers -
SAINT-GOBAIN HES is the
branch in Germany for cast
iron wastewater pipe systems
and supplies PAM-GLOBAL

cast iron pipes to customers in


Germany and abroad.
Liability
The PAM-GLOBAL

S manual is written for general guidance only. Therefore no responsibility can be


accepted for any mistakes, omissions or incorrect assumptions. SAINT-GOBAIN HES does not accept
liability for any claims on installations where components not manufactured by SAINT-GOBAIN PAM
should be involved in a system failure.
Whilst every care has been taken to ensure that information contained in this catalogue is correct,
SAINT-GOBAIN HES or its agents do not accept responsibility for any mistakes herein. Our policy is
one of continuous improvement. We therefore reserve the right to change or alter any product
characteristics without prior notice.
Infringement of SAINT-GOBAIN HES Copyright
No part of this manual can be partly copied, biased or modified by any means without the written
consent of the copyright owner.
7
SAINT-GOBAIN HES - Cast Iron Pipe Systems
PAM-GLOBAL


- Soil and Drain
Cast Iron Specification
About Us
PAM-GLOBAL


Systems
PAM-GLOBAL


S Pipes - Coating
PAM-GLOBAL


Fittings - Coating
Quality Certifications
Fire Protection
Noise Insulation
Environmental Awareness
PAM-GLOBAL


S - Products
PAM-GLOBAL

- Couplings, Grip Collars and Connectors


Installation Instructions
PAM-GLOBAL

EPAMS

Syphonic Roof Drainage System


References
Contents
2-3
4
5
6
8
9
10-11
12-13
14-15
16-17
18
19-30
31-35
36-37
38-41
42-43
PAM-GLOBAL

Systems
8
In the De Lavaud process the molten metal is gradually input into a steel mould rotating
at high speed. The process is characterised by its quick cooling that gives a finer
solidification matrix and a more homogeneous metallurgical structure.
SEM Photo: Rosette-shaped
graphite formation of
PAM-GLOBAL

pipes
SEM Photo: Graphite formation in
regular lamellar cast iron
Heat treatment
After being spun the PAM-GLOBAL

pipes
are placed and rotated in a heat treatment
furnace at 950C and then gradually cooled
again. This step is essential to the process
as it transforms the cast iron's metallurgical
structure. The reduction of iron carbides and
the increase of ferrite content considerably
improve the mechanical properties of cast
iron and reduce its surface hardness. The
graphite of the cast iron resulting from the
SAINT- GOBAIN PAM process forms
clustered graphite, halfway between lamellar
and ductile iron.
Main advantages of the De Lavaud process
Tensile Strength on samples
in MPa (average value)
Ring Crush Strength
in MPa (average value, DN 100 pipes)
Brinnell Surface Hardness
in HB degree (average value)
The pipes
Saint Gobain PAM
process
300
450
220
Others
270
360
245
EN 877 requirements
200 min.
350 min.
260 max.
These results indicate greater resistance to impacts and crushing, easier machining and cutting. This also
means the products are easier to install on job sites.
9
PAM-GLOBAL

S Pipes - Coating
New epoxy-resin
inner coat with
optimised properties
(130 m)
Cast iron
De Lavaud process
Outer coat
(acrylic primer 40 m)
2
2
3
3
1
1
PAM-GLOBAL

S Products and couplings with EPDM gaskets


Dilution
pH
23 50 65 70
Test
duration
SALT WATER Same as sea water
30g/
l
DETERGENTS
28j
Laundry detergents 2ml /l 7,7 28j
Phosphate free wash
Softener
2ml/l 7,6 28j
Dish washer detergents Washing tablet
3g/l 9,3 28j
Washing gel
3g/l 9,8 28j
Washing up liquid
2ml/l 7,65 not applicable 28j
Stain remover Type ACE GENTLE"
7,7 28j
COMBINATION Wash + stain remover
2ml/l+ 3ml/l
7,7 28j
Wash + Softener
2 ml + 3ml/l 7,7 28j
CLEANINGPRODUCTS 8ml/l 8,2
not
applicable
28j
Bleach
Floor cleaning product
8ml/l 8,25 not applicable 28j
WC CLEANERS 20ml/l 5,45
not applicable
28j
r D ain cleaner gel 0,33 ml/l 13 4j
Liquid descaler 80ml/l 2,07 28j
To provide clearer guidance on the
chemical resistance of S range in
domestic applications,
SAINT-GOBAIN PAM has carried out
20 additional tests to the EN 877
Standard requirements on detergent
products and special products of
common use. The tests were carried
out on samples, under the temperature
of use recommended by the
manufacturers and where it was
relevant, up to 70C since hot water
is normally supplied in dwellings around
50 - 60C. After stopping the test, the
pipes and fittings shall be washed
immediately to eliminate any stains and
the coatings shall be examined with
regard to blistering and rusting both
according to ISO 4628-2 and 3.
(Accepted levels according EN 877)
The duration of the test would potentially be equivalent to the extrapolation of a real chemical stress undergone during 7
or 10 years (a 10 to15 min stress per day). This test method however simulates a more severe stress since the samples lie
in direct contact with the solution, the temperature being maintained and the test includes no rinsing over its duration.
= Resistance
The coatings principle is to offer consistent performance for pipes, fittings and accessories without any weak
points. So that you can be sure of the products you specify and to fit important changes recently noticed on fluids
carried disinfectants, hygiene products - SAINT-GOBAIN PAM regularly makes assessments on coatings.
They are continuously upgraded to provide high protection level against corrosion, and long-lasting properties
to protect the pipe work lifespan.
The inner coating of the PAM-GLOBAL

S pipes has been designed to withstand most chemical stress and resist
abrasion. Made of an epoxy-resin regularly assessed, this coating benefits from continuous improvement to meet
waste water drainage increasing constraints. Its smooth surface enhances flow capacity and prevents incrustations
and deposits. The inner coatings of pipes and fittings have been paired for PAM-GLOBAL

S system consistency,
to withstand equivalent stress and to ensure no weak link could affect the pipe work durability.
The coatings performance of PAM-GLOBAL

S pipes and fittings exceeds by far EN 877 requirements.


Toilet bowl cleaner (gel)
10
PAM-GLOBAL

Fittings - Coating
Oven drying180C
7
in order to enhance the
coating's covering power.
The coating is composed of
pigments and an epoxy
bonding in a water solution,
which uniformly deposit on
the fittings surface.
The deposited film shows
1 2 3 4 5 6 7 8
Shot blasting
1
Rinsing 2
Hot phosphate process
3
Rinsing 4
Superior cataphoresis
5
Rinsing 6 Cooling 8
Coating Process for PAM
GLOBAL

Fittings :
The common coating for
fittings is an epoxy resin
deposited through a
cataphoresis process.
However other processes,
like fluidised bed, can be
used to meet specific
requirements.
Internal - external:
Epoxy-film - brown-red colour
- deposited by cataphoresis
and thermoreticulated.
Technology:
Cataphoresis is a coating
process which deposits a film
of regular thickness on
an electrically charged
metallic surface.
This process has long been
recognized as the most
successful technology for
surface coating in the
automotive field, but it was
first used for cast components
by SAINT-GOBAIN PAM.
Reliability:
The optimised process by
SAINT-GOBAIN PAM is
based on a careful shot-
blasting and a specific
chemical surface treatment,
excellent adhesion and
high impact resistance.
Performance:
Resistance to salt
spray test above 1500
hours.
The cast iron components are conveyed through different tanks after being shot blasted.
Cataphoresis is a fully automated painting process offering significant benefits.
PAM-GLOBAL

pipes are marked


as shown in the above image.
DN attribute varies
according to the nominal
diameter of each pipe: e.g.
PAM-GLOBAL

S DN 100.
CE marking indicates that the
product meets basic safety
requirements. A2-s1,d0 stands
for the reaction to fire ranking
we chose to display.
GEG marking indicates a
superior Quality Mark for cast
iron drainage pipes and fittings.
01-10 stands for the week and
year the pipe was manufactured.
PAM-GLOBAL

fittings
supplied by SAINT-GOBAIN
HES GmbH are marked with
a framed label. These
embossed frames
are patented.
Identification Marking
11
Advanced coating method
for PAM-GLOBAL

fittings
provides flawless adhesion
and good protection of the
edges and thus a better
corrosion resistance.
Complete and compatible
pipes, couplings, fittings and
accessories: PAM-GLOBAL

offers a comprehensive range of


products.
Combined with coatings and
couplings the PAM-GLOBAL

range
builds consistent pipe systems
benefiting from the outstanding
robust properties of cast iron.
PAM-GLOBAL

Quality Certifications
12
ISO, International Standards
ISO 9001 certification is the recognition by a third party (accredited organization)
that the quality management system of the company fully complies with the standards
requirements.
It is recognized in more than 70 countries. It covers such company activities
as quality control, R&D, production technologies, company organization and customer
service.
ISO 14001:2004 Environmental Management System.
The certificate of compliance proves that the company has a global approach to minimize
the impact made to the environment throughout manufacturing process: Gwuidelines for
improvement, action plans and better follow-up procedures.
PAM-GLOBAL

cast iron elements are made from 95% of metal scrap and are 100% recyclable;
thus, the impact on environment is really minimized.
EN 877 Standard
The European standard EN 877 Cast iron pipes and fittings, their joints and accessories for
the evacuation of water from buildings , known to be the most demanding standard worldwide,
sets up technical specifications as well as test methods and quality control.
This leads to:
Mechanical performances
Respect of dimensions
Special requirements on couplings
Efficient traceability of production sites.
13
Quality marks are voluntary. Their scope is aiming at fitness for purpose and at valuing the
product in a customer-supplier relationship.
Unlike Quality Marks, CE marking is mandatory to be allowed pass into the European Union
and between member states.
Made compulsory by the European Directive for Construction product, its scope is limited to
health and operational safety. CE marking is a minimum precondition to guarantee that
construction products are not dangerous for the European consumers and users. It sets the
same safety criteria shared all over Europe and is mainly intended for the authorities in charge
of market control.
Reaction to fire alone was retained as safety criterion for drainage systems (see Fire protection
chapter).
Based on EN 877, CE marking became mandatory on cast iron drainage products leaving
the factory, from 2009 September the 1st.
For Construction Products, reaction to fire is assessed on the basis of standardised tests and
described in a EUROCLASS classification. For complete ranges pipes, fittings, couplings
and accessories SAINT-GOBAIN PAM has obtained the excellent EUROCLASS ranking:
A2, s1-d0, now mentioned on the products.
EUROCLASS being based on test methods and a classification harmonised throughout Europe,
the scoring can be used to compare materials and product performances you specify.
CE Marking
Compliance with standards
Voluntary Quality Mark GEG RAL-GZ 698
Being self declared, EN 877 is only proved when third party validated on all criteria and
periodically tested.
Recognised quality mark, GEG (Gtezeichen Entwasserungstechnik Guss) has set forth a
list of testing criteria and quality requirements far exceeding those included in EN 877.
Meeting all these requirements is the first and foremost condition to obtain a RAL-GEG
marking. Third-party inspections are carried out by MPA-NRW twice a year.
Cast iron pipes and fittings, their joints and accessories for the evacuation
of water from buildings.
Requirements, test methods and quality assurance
Cast iron drainage pipes and fittings (spigot)
Elastomeric seals - Material requirements
Requirements for a quality management system design, product development,
production, installation and after sales support
Environmental management system
Requirements with guidance for use
Fire tests
Fire classification of construction products and building elements.
Classification using data from reaction to fire tests
Reaction to fire tests for building products - Part 1. Building products
excluding floorings exposed to the thermal attack by a single burning item
Measurement of noise
Laboratory measurement of noise from waste
water installations
European Standard International Standard
EN 877
EN 681-1
EN 13501
EN 13823
EN 14366
ISO 6594
ISO 4633
ISO 9001
ISO 14001
Testing standards
Fire Protection
14
System Characteristics
PAM-GLOBAL

cast iron pipe


systems are flame proof ,
and have outstanding
properties not to spread the
fire. This is confirmed by tests
carried out both domestically
and abroad
(C.T.I.C.M./IBMB).
Test certificate No.:
P-3725/4130-MPA BS.
For high fire proofing
requirements in the structural
engineering sector,
specifying PAM-GLOBAL

pipe systems is the


reasonable choice.
The most important
benefits of
PAM-GLOBAL

cast iron pipe


systems
Material Classification
PAM-GLOBAL

pipes and
fittings are made of cast iron
with lamellar graphite
according to DIN EN 1561.
This material conforms to the
Class A1 Building Material
according to DIN 4102 in
Germany and is non
combustible.
Fire Load
Cast iron pipes and fittings
are considered non
combustible.
Their fire loads do not need
to be taken into account.
The Fire load of a product
is defined as follows: it is the
quantity of energy released
during combustion. It highly
depends on the type and
quantity of flammable
materials used for the product
manufacturing.
Formerly, a fire load of 7
KWh/m was authorised in
emergency corridors.
This regulation is no longer
applicable due to the general
Pipe Systems Guidelines,
whereby fire loads are no
more permitted on
emergency corridors or
emergency exits.
Comparison: 1 kg of
polyethylene (PE) produces
a fire load of 12 KWh. 1 kg
of heating oil has a gross
calorific value of 11.7 KWh.*
Smoke Development
In the event of a fire, the
PAM-GLOBAL

pipe system
remains sealed; smoke that
could develop inside the
pipes is dissipated via the
rooftop main ventilation.
Comparison: 10 kg of
polyethylene (PE) or
polypropylene (PP) produces
approximately 23,000 m
3
of
highly toxic smoke,
consisting of carbon
monoxide, carbon dioxide
and soot.*
Thermal Expansion
The thermal expansion
coefficient of cast iron is only
0.0105 mm/m.K.
Under a temperature change
of 50 K, the expansion of a
DN 100 pipe of 10 m length
is only 5.3 mm. This
expansion is absorbed by
the couplings.
* Source: Bernd Prmer
Brandschutz in der
Haustechnik Gentner Verlag.
concrete
filling
concrete
filling
15
Fire Protection
For fire safety in a building, the major responsibility
rests with the project manager who must respect
the regulation in force. In buildings at risk, such
as multi-storey buildings, materials with reduced
flammability should be selected to apply
precautionary principle.
Reaction to fire is the instant behaviour when a
fire breaks out, its propensity to ignite or feed a
fire. For drainage systems to obtain CE marking,
Reaction to fire requires a mandatory certificate,
stipulating their EUROCLASS classification, issued
by an accredited and independent laboratory.
Cast iron as a material itself is classified as A1
in the Euroclass classification for reaction to fire.
In tests carried out by the CSTB accredited
laboratory, SAINT-GOBAIN PAM cast iron ranges
(pipes, fittings and accessories including elastomer
gaskets and coatings) received the following
excellent Euroclass ranking: A2 -s1, d0.
For smoke emission and the production of flaming
droplets, the SAINT-GOBAIN PAM products
respectively achieved the highest possible rating:
s1 and d0.
So, cast iron remains one of the safest drainage
material for fire safety.
Fire resistance is a construction component's
ability to withstand fire for a given period of time
and to retain its serviceability in the event of fire.
SAINT-GOBAIN PAM cast iron has a melting point
over 1000C. In most cases it requires no
additional fire protection. SAINT-GOBAIN PAM
has carried out a non exhaustive series of tests
on its cast iron pipe systems in order to make
precise recommendations for fire resistance
requirements up to 240 minutes (4 hours).
SAINT-GOBAIN PAM cast iron pipes are
non combustible, they do not feed the fire, nor
give off either gases or smokes liable to delay fire
fighters or damage other equipment.
Examples of tested downpipes penetrating slabs solutions with PAM-GLOBAL

S system
DN 50 to DN 150
(Cert. No: P-MPA-E-07-028)
E.g. in production plants,
parking lots, warehouses,
regardless of noise
insulation
For combustible pipes
(HDPE, PVC, PP etc.)
larger than DN 32, fire
spreading measurements
and test results are an
absolute requirement, so
that the fire regulation
can be applied.
Slab penetration shall
be limited to the
technically required size.
Slab sealing for open
hoppers shall be made of
non combustible
materials, e.g. cement
mortar, concrete or
mineral wool.
If mineral wool is used, it
must have, in accordance
with MLAR, a melting
point 1000 C and a
relative density of at least
90 kg/m
3
.
For acoustic requirements
beware that if cement
only is used, the sealing
can cause sound bridges.
According to MLAR,
shafts used for insulation
or sound insulation, in
the vicinity of the ducts
surface or walls with fire
break requirements, shall
also be made of mineral
casings of the above
mentioned quality.
Noise Insulation
16
Airplane Noise Music Traffic Clock Snowfall
PAM-GLOBAL

Acoustic Dampener
The acoustic dampener is designed to reduce structure-borne
noise propagating through connections between the pipe system
and the building. This accessory, made of a stainless steel casing
surrounding an elastomer shock absorber, is fitted between the
back of the bracket and the structure (wall, ceiling, etc...). It can
be used on any cast iron pipe bracket from DN 50 to DN 150,
installed horizontally or vertically. With PAM-GLOBAL

dampener,
such low values as 5 dB(A) in a 2 l/s flow rate can be achieved
independent of how tight the bracket is screwed.
DIN 50 - 150
02 - 07
(Date of Manufacture)
DN
50 - 150
Product Code Weight
0,11 205113
Waste water and rainwater drainage generates airborne and structure-
borne noise between rooms, which usually result from a mixed flow, when
the pipe is filled with water and air.
Under such circumstances a pipe will radiate noise outwards to any
lightweight ceilings, cupboards and similar areas wherever it makes contact.
What Exactly is Plumbing Noise?
Airborne noise (A)
When a material is dense and thick, the
pipe walls prevent air transmission;
as is the case with cast iron which offers
intrinsic acoustic properties.
Structure-borne noise (B)
When the noise produced within a pipe
is not transmitted by the air, the
residual noise is transmitted by
structural vibrations. Whilst the
mass of the cast iron limits the
vibratory level, the junctions and
fixing to the building will propagate
noise. Objective: Dampen the
vibrations at the connections with
the solid structure.
35 dB(A)
standard for
kitchen and
bathroom
30 dB(A)
standard for living
room and bedroom
26 dB(A)
PAM-GLOBAL

pipe
with standard bracket
noise is divided
by 2,5
19 dB(A)
PAM-GLOBAL

pipe
with rubber lined
bracket noise is
divided
by 5
17
Noise Insulation
EN 14366 complying test results obtained for a flow rate of 2 l/s and a wall thickness of 25050 kg/m
2
(IBP laboratory)
Requirements defined
by DIN 4109 and VDI
Drainage installations must
be designed in accordance
with DIN 4109/A1. This
standard defines the
expected requirements for
noise control with the aim of
protecting people in
residential rooms from
unreasonable nuisance
caused by sound
transmission.
DIN 4109-1989 specifies
the expected requirements
regarding the maximum
noise level for
rooms requiring noise
insulation. These include
living rooms, bedrooms,
workrooms and classrooms.
Such requirements do not
apply to room partitions
within the same dwelling.
As a result of its endorsement
by the building authorities
DIN 4109/A1 is now made
compulsory under public law.
However, it only sets a
minimum requirement.
The VDI Guidelines 4100
define 3 sound insulation
levels (SSt).
These 3 levels can cover all
sound insulation requirements
and they are to be promoted
between all actors involved
in building projects including
further occupants on the basis
of private law.
To avoid subsequent disputes
it is highly recommended that
the sound insulation level
requirements (SSt) should be
stipulated in the contracts.
5 dB(A)
PAM-GLOBAL

pipe
with acoustic dampener
noise is divided
by 25
Test results for the PAM-GLOBAL

pipe systems
Environmental Awareness
18
PAM-GLOBAL

cast iron pipe


systems are made of
recycled scrap metals and so
save natural resources. Unlike
plastics, it can be completely
and systematically recycled
at the end of its life through
processes that are not harmful
to the environment.
As the world leader in
construction products,
SAINT-GOBAIN aims at
providing innovative solutions
to take up the challenges for
the future posed by
environment protection and
energy savings. All the
products of the Group are
designed with a view to
making full allowance for
environmental issues and
enhancing the energy
efficiency of buildings.
PAM-GLOBAL

cast iron pipe systems are based on the principle of


modular ranges of removable components. Their mechanical assemblies
are reversible. You can change your mind today or even tomorrow.
When pipe systems are disassembled or modified, these components
can be reused, which cuts down waste dumping.
PAM-GLOBAL

pipe systems can be recycled without any deterioration


of their properties, so they can be reused for exactly the same purpose.
In other words, a pipe can be recycled as pipe.
Owing to the stability of their mechanical properties, it is currently
admitted that the service life of PAM-GLOBAL

pipe systems is twice


that of alternative products made of plastic materials.
For its recycled content, its actual recycling and long lasting properties,
PAM-GLOBAL

cast iron can be considered environment friendly.


The Right Choice
For Green Buildings
100% recyclable
indefinitely without
losing any of its
properties.
PAM-GLOBAL

S - Products
PAM-GLOBAL

S Pipes and Fittings (DIN EN 877 and DIN 19522)


PAM-GLOBAL

S Pipes
L = 3000 mm
DN weight Product Code
50
70
80
100
125
150
200
250
300
12,50
17,00
18,20
24,30
34,30
40,90
67,40
97,30
126,80
156361
156454
156550
156561
156734
156825
156949
157048
157113
0,18
0,25
0,26
0,35
0,42
0,50
0,65
0,85
1,02
Nominal
Diameter
DN DE Tolerance
Exterior-
e
Tolerance of pipes
and fittings
Coupling
distance
t
empty
kg/m
full
kg/m
Weight
(approx.)
Surface
approximate m
2
per meter
50
70
80
100
125
150
200
250
300
58
78
83
110
135
160
210
274
326
+2
-1
+2
-2
+2,5
-2,5
3,5
3,5
3,5
3,5
4,0
4,0
5,0
5,5
6,0
-0,5
-0,5
-0,5
-0,5
-0,5
-0,5
-1,0
-1,0
-1,0
30
35
35
40
45
50
60
70
80
4,2
5,9
6,1
8,1
11,4
13,6
22,5
32,4
42,3
4,3
9,9
10,6
16,4
24,1
31,7
53,9
86,7
119,7
On request for DN 400, 500 and 600.
Wall Thickness
19
All dimensions are in mm and nominal weights in kg.
Pipe Coupling Fitting
PAM-GLOBAL

S - Products
20
DN X
50
70
80
100
125
150
200
0,72
1,24
1,30
2,00
3,20
4,10
7,80
75
90
95
110
125
145
180
Weight Product Code
155749
155778
176706
155813
155867
155900
155930
PAM-GLOBAL

S - 88 Bend
50
70
80
100
125
150
200
0,72
1,20
1,05
1,75
2,90
4,10
7,10
65
75
80
90
105
120
145
155750
155779
176705
155814
155868
155901
156968
PAM-GLOBAL

S - 68 Bend
50
70
80
100
125
150
200
250
300
0,56
0,90
0,79
1,40
2,25
3,00
5,30
9,50
15,90
50
60
60
70
80
90
110
130
155
155751
155780
176704
155815
155869
155902
155931
155947
155959
PAM-GLOBAL

S - 45 Bend
50
70
80
100
125
150
200
250
300
0,47
0,92
0,79
1,40
2,00
3,00
5,10
9,50
13,80
45
50
50
60
70
80
95
110
130
155753
155782
176703
155817
155871
155904
155933
155948
155960
PAM-GLOBAL

S - 30 Bend
50
70
80
100
125
150
200
0,47
0,63
0,68
1,15
1,77
2,40
4,35
40
45
45
50
60
65
80
155752
155781
176702
155816
155870
155903
155932
PAM-GLOBAL

S - 15 Bend
DN X Weight Product Code
DN X Weight Product Code
DN X Weight Product Code
DN X Weight Product Code
PAM-GLOBAL

S - Fittings
21
PAM-GLOBAL

S - 88 Bend (long tail)


DN X
1
70
80
100
2,80
2,90
3,60
250
250
250
155785
179681
155823
X
2
90
95
110
K
160
160
140
PAM-GLOBAL

S - 45 Bend (long tail)


DN X
1
70
80
100
2,60
2,70
4,20
250
250
250
155786
179680
155824
X
2
60
60
70
K
190
190
180
PAM-GLOBAL

S - 88 Double Bend
DN X
1
50
70
80
100
125
150
1,00
1,70
1,50
3,10
4,20
7,00
50
60
60
70
80
90
155754
155783
176707
155819
155872
155905
X
2
100
120
120
140
160
180
x3
121
145
145
170
195
219
DN X
1
70
80
100
125
150
3,20
3,20
4,80
6,10
9,60
60
60
70
80
90
155784
179679
155820
155873
155906
X
2
301
301
312
322
334
x3
273
273
291
308
326
PAM-GLOBAL

S - 88 Double Bend (long tail)


(For connecting downpipes with
horizontal lines, DIN 1986-100)
PAM-GLOBAL

S - Products
PAM-GLOBAL

S Offset
DN X
100 2,00 70 155812
L
205
PAM-GLOBAL

S Offset (A) = 65mm


DN X
100 3,76 70 155821
L
270
PAM-GLOBAL

S Offset (A) = 130mm


DN X
100 4,50 70 155822
L
340
PAM-GLOBAL

S Offset (A) = 200mm


Weight Product Code
Weight Product Code
Weight Product Code
Weight Product Code
Weight Product Code
Weight Product Code
Weight Product Code
PAM-GLOBAL

S - Products
22
PAM-GLOBAL

S - 135 Bend
DN X
100 5,00 312 155818
K
100
L
150
K= Maximum zone of possible cut
PAM-GLOBAL

S - 45 Branch
DN X
1
50x50
70x50
80x50
70x70
80x80
100x50
100x70
100x80
100x100
125x50
125x70
125x80
125x100
125x125
150x70
150x80
150x100
150x125
150x150
200x70
200x80
200x100
200x125
200x150
200x200
250x100
250x125
250x150
250x200
250x250
300x100
300x125
300x150
300x200
300x250
300x300
50
40
45
55
60
35
50
50
70
20
40
51
60
80
30
50
55
70
90
15
20
40
55
75
115
15
35
55
90
130
5
15
35
70
115
155
155769
155789
173786
155806
173787
155828
155831
173788
155857
155877
155879
176716
155882
155895
155910
176733
155912
155914
155926
155934
176734
155935
155936
155937
155944
155949
155950
155951
155952
155956
155961
155962
155963
155964
155965
155968
X
2
135
150
135
160
155
165
185
185
205
185
200
189
220
240
215
220
240
255
265
240
240
280
295
315
340
310
335
350
385
430
345
360
380
440
465
505
L X
3
135
150
135
160
155
165
185
185
205
185
200
189
220
240
215
220
240
255
265
240
240
270
285
300
340
310
335
350
385
430
345
360
380
415
465
505
185
190
180
215
215
200
235
235
275
205
240
240
280
320
245
255
295
325
355
255
260
310
340
375
455
325
370
405
475
560
350
375
415
485
580
660
1,35
1,87
1,60
2,10
2,20
2,40
2,80
3,18
3,80
3,24
4,30
4,20
5,60
5,70
5,10
5,30
6,12
7,00
8,75
7,00
7,34
9,33
10,69
12,32
16,78
15,40
16,00
17,25
22,40
29,00
19,30
21,00
28,00
28,10
37,60
46,30
Weight Product Code
Weight Product Code
PAM-GLOBAL

S - 88 Branch
DN X
1
50x50
70x50
80x50
70x70
80x80
100x50
100x70
100x80
100x100
125x50
125x70
125x80
125x100
125x125
150x50
150x70
150x80
150x100
150x125
150x150
200x100
200x200
79
83
85
97
95
94
102
100
115
98
107
105
125
137
100
115
115
130
147
158
145
155767
155787
176718
155804
176719
155827
155829
176720
155855
155876
155878
176722
155880
155894
155908
155909
176723
155911
155913
155925
156980
157024
X
2
80
90
90
95
95
105
110
110
115
120
125
125
130
135
140
140
140
145
150
155
175
L X
3
66
72
75
83
85
76
88
90
105
82
93
100
110
123
100
100
105
115
128
142
125
145
155
160
180
180
170
190
190
220
180
200
205
235
260
200
215
220
245
275
300
270
1,00
1,33
1,40
1,70
1,80
2,05
2,46
2,44
2,65
2,80
3,20
2,90
4,20
5,00
3,90
4,70
4,36
5,50
6,10
5,75
8,80
10,40
PAM-GLOBAL

S - 45 Double Branch
DN
100x100
125x125
150x150
156709
156817
156936
L
260
305
360
4,60
7,50
12,00
190
230
270
X
3
190
230
270
L
X
1
70
75
90
X
2
X
2
X
1
X
3
23
PAM-GLOBAL

S - Products
Weight Product Code
PAM-GLOBAL

S - 88 Double Branch
DN X
1
100x50x50
100x70x70
100x80x80
100x100x100
125x100x100
150x100x100
94
102
100
115
130
130
155825
155826
179685
155858
155874
155907
X
2
94
102
100
115
130
130
L X
4
76
88
90
105
115
115
180
190
190
230
245
245
2,20
2,70
2,70
3,70
5,00
7,10
X
3
105
110
110
120
135
145
X
5
76
88
90
105
115
115
Weight Product Code
PAM-GLOBAL

S - 70 Branch
DN X
1
50x50
70x50
70x70
100x100
125x100
55
55
70
85
85
155768
155788
155805
155856
155881
X
2
80
90
100
130
145
L
135
145
170
215
225
1,00
1,30
1,70
2,75
3,93
X
3
80
90
100
130
140
Weight Product Code
Weight Product Code
PAM-GLOBAL

S 88 Corner Branch
DN X1
80x80x80
100x70x70
100x80x80
100x100x100
125x70x70
125x100x100
150x100x100
95
102
100
115
107
125
130
179682
155839
179683
155860
155888
155889
155919
X2
95
110
110
120
125
130
145
L
180
190
190
220
200
235
245
2,00
2,70
2,75
3,43
3,70
5,00
7,10
X3
85
88
90
105
93
110
115
PAM-GLOBAL

S 88 Branch (long tail)


DN X1
100x100 325 155861
X2
115
L
430 4,60
X3
105
K
210
Particulary suitable for slab penetration.
PAM-GLOBAL

S 88 Corner Branch (long tail)


with 90 Corner Angle
DN X1
100x100x100 325 155862
X2
115
L
430 5,20
X3
105
K
210
Particulary suitable for slab penetration.
PAM-GLOBAL

S - Products
24
Weight Product Code
Weight Product Code
Weight Product Code
25
PAM-GLOBAL

S - Products
DN H
100 x 70 x 100
100 x 80 x 100
100 x 100 x 100
4,50
4,27
4,30
230
230
230
171524
176658
175605
PAM-GLOBAL

Combination Branch
The combination branch
enables simultaneous
connection of multiple
plumbing elements. Due
to its specific shape, it
can be used to connect
PAM-GLOBAL

S Special
Fittings
Used in the simultaneous
connection of multiple
plumbing elements (main
pipe and WC outlet DN
100).
The remaining 2 outlets
with an internal diameter
of 59 cm are for push-fit
connectors.
Special Fittings
Left
Weight
5,80
Product Code
155848
Special Fittings
Right
Weight
6,00
Product Code
155847
Weight Product Code
downpipes in shafts,
adjacent sanitary blocks
and generally wherever
the space for wastewater
connections is limited.
PAM-GLOBAL

S Typical Applications For Combination Branches


WC
Sink
Finished Floor
Tub
Sink
WC
The combination branch
enables connection of WC and
another plumbing element (e.g.
bathtub), at the same floor level.
The 45 angle of outlets is
double-sided to allow the
combination branch to be
installed in a 180 rotated
position.
26
DN D1
50
70
80
100
125
150
200
250
300
D2 A
150
170
175
214
228
255
310
394
448
108
112
133
162
187
222
278
354
406
195
215
218
259
275
300
362
444
398
179217
179218
176713
179219
179220
179221
179222
179223
179224
Nr.
0,80
1,10
1,20
1,30
1,50
2,00
2,30
5,60
7,40
B C kg.
33
30
33
33
33
33
36
40
40
17
19
20
20
20
22
22
25
30
DN A
70 x 50
80 x 50
100 x 50
100 x 70
100 x 80
125 x 50
125 x 70
125 x 80
125 x 100
150 x 50
150 x 70
150 x 80
150 x 100
150 x 125
200 x 100
200 x 125
200 x 150
250 x 150
250 x 200
300 x 150
300 x 200
300 x 250
L t2 t1 Weight Product Code
10
13
25
16
14
38,5
28,5
26
12,5
51
41
39
25
12,5
50
37,5
25
57
32
83
58
26
75
80
80
85
90
85
90
95
95
95
100
100
105
110
115
120
125
140
145
150
160
170
35
35
40
40
40
45
45
45
45
50
50
80
50
50
60
60
60
70
70
80
80
80
30
30
30
35
35
30
35
35
40
30
35
35
40
45
40
45
50
50
60
50
60
70
0,64
0,70
0,80
1,05
0,95
1,50
1,40
1,30
1,60
1,90
1,80
2,00
1,95
2,00
3,60
3,80
3,40
6,30
10,70
10,70
10,20
10,70
155763
176727
155764
155801
176728
155765
155802
176730
155842
155766
155803
176732
155843
155892
155844
155893
155922
155923
155942
155924
155943
155955
DN D
50
70
80
100
125
150
200
250
300
L Weight
87
106
118
145
170
195
245
340
390
220
220
220
220
220
220
220
300
300
1,30
1,60
1,80
2,40
3,20
4,10
5,90
12,35
17,80
156372
155773
156462
156577
156745
156837
156959
157058
157123
Product Code
PAM-GLOBAL

S - Products
PAM-GLOBAL

S Taper
PAM-GLOBAL

S Stack
Support Pipe
PAM-GLOBAL

S Stack Support Bracket


PAM-GLOBAL

S - Products
PAM-GLOBAL

S Short Pipe With Access Door, Round Opening


For Connecting, Vertical and Horizontal pipe works
DN H
50
70
80
100
59
69
71
84
Weight Product Code
179191
155799
179647
179192
d1
53
73
73
104
L
190
210
210
260
2,30
3,00
3,20
5,00
d2
105
125
125
159
EPDM O-Ring gasket
Hardness: 45 Shore A
PAM-GLOBAL

S Short Pipe With Access Door, Rectangular Opening


For Ground, Vertical and Horizontal pipe works
DN H
100
125
150
200
250
300
83
101
112
137
170
195
Weight Product Code
179196
179197
179198
179199
179200
179201
G
160
190
215
262
330
380
F
230
255
280
330
380
430
7,60
10,30
14,50
22,00
38,50
50,00
d
100
125
150
200
260
310
A
200
225
250
300
350
400
L
340
370
395
485
570
640
Supplied with EPDM sealing
system in DN 100-200
Hardness: 45 Shore A
Supplied with 6 screws and
EPDM sealing system in
DN 250-300
PAM-GLOBAL

S Short pipe with Access Door Round, Twist-on Opening


For Vertical and Horizontal pipe works
156414
156513
156659
156794
156905
157015
157098
157161
DN H
50
80
100
125
150
200
250
300
73
89
102
125
142
165
196
222
Weight Product Code d1
75
101
128
154
181
181
181
181
L d2
108
134
160
189
224
224
225
227
160
205
250
280
320
360
380
400
1,96
3,15
4,50
6,48
10,38
14,00
19,70
26,30
1- Operation safety:
Possible bleeding before
opening in case of
accidental overpressure.
2- Convenience:
Ease of opening and closing
the cast iron plug with
standard tools or a T-handle
operating wrench
3-4 The cast iron plug and the
internal sealing can be removed
separately.
27
1 2 3 4
28
PAM-GLOBAL

S - Products
PAM-GLOBAL

S Blank End
155747
155776
176700
155809
155865
155898
155928
155945
155957
DN
50
70
80
100
125
150
200
250
300
Weight Product Number L
30
35
35
40
45
50
60
70
80
0,25
0,40
0,45
0,80
1,20
1,70
3,20
5,90
10,00
PAM-GLOBAL

S Expansion Plug
156374
156468
156464
156579
156747
156839
156961
DN
50
70
80
100
125
150
200
Weight Product Number L
25
45
45
57
55
53
54
0,34
0,66
0,7
1,25
1,7
2,4
5,2
L
For DN 250 and 300 expansion plugs are now replaced with blank ends
PAM-GLOBAL

S Blank End With Clamp


179234
179235
179236
179237
DN
100
125
150
200
Product Number Weight
2,50
3,50
4,50
6,00
a
1)
90
90
95
95
Clamp material: St 37.
Supplied with galvanized
EPDM sealing.
The clamp consists of
3 parts in sizes DN
150 and DN 200.
a
1)
Min. length top edge
of nut
DE
62
85
90
118
143
168
220
29
PAM-GLOBAL

S - Products
156420
156521
176714
156668
156801
156912
157018
DN I
50
70
80
100
125
150
200
190
265
265
325
390
470
600
Weight Product Number h
250
293
293
392
446
493
600
X
1
182
200
200
282
316
348
420
68
93
93
110
130
145
180
2,90
5,48
5,85
9,50
14,35
21,75
38,38
X
2
122
172
172
215
260
325
400
X
3
68
93
93
110
130
145
200
X
4
w
60
60
60
100
100
100
100
PAM-GLOBAL

S Stench Trap
Cleaning access on the bottom from
DN 50 to 150.
PAM-GLOBAL

S branch
traps are preferably used
on rainwater systems.
Branch traps must be
installed vertically to keep
the adequate depth of
water seal but are suitable
for horizontal and/or
vertical pipework route.
They can be installed on
vertical pipe works if
combined with bends.
Arrows stamped on the
body indicate flow
direction.
90 Double Bend WC Connector
Only Fit For Vertical Assembly
155853
DN
100
Weight Product Number X
1
225 85 5,70
X
2
250 50
A K
90 Bend WC Connector
176725
155852
DN
80
100
Weight Product Number X
1
145
150
55
44
2,00
3,00
X
2
50
40
X
3
105
84
X
4
WC Connector
155845
DN
100
Weight Product Number
2,90 225 170
K L
PAM-GLOBAL

S - Products
30
Connecting PAM-GLOBAL

S Pipes to the Sewer System


Connecting PAM-GLOBAL

Pipes to Clay Pipe With Socket Type L acc. to DIN EN295


DN 100 - 200
PAM-GLOBAL

pipe
Stepping ring in
compliance with EN 295
L socket
PAM-GLOBAL

Pipe to PVC Sewage Pipe


PAM-GLOBAL

pipe
Rollfix connector
KGUG cast iron adaptor
KG sewage pipe in compliance
with DIN 19534
D
d
l
180983
180984
180985
180986
DN
100
125
150
200
Rollfix
Code
179801
179802
179803
179804
KGUG-Adaptor
Code
124
151
176
226
DN
100
125
150
200
60
65
70
80
110
125
160
200
D
mm
d
mm
l
mm
Size chart for KGUG cast iron adaptor
179686
179687
179688
179689
DN
100
125
150
200
Product Code
Stepping ring
Connections to other materials
Connecting cast iron pipe systems to other
materials may be required in new
construction projects or to ease renovation.
Their external diameters may differ and
solutions exist for compensation.
Please check the page 35 and contact our
Technical Support for solutions available
and dimension tables per material.
31
PAM-GLOBAL

Couplings
PAM-GLOBAL

RAPID NG Coupling
DN 50 - DN 300
DN D
50
70
80
100
125
150
200
70
85
90
125
147
172
223
80
98
103
139
161
187
240
42
42
42
48
56
56
70
210424
210425
210426
210427
210428
210429
210430
Code H L
Max. dimensions after installation
0,10
0,12
0,12
0,18
0,28
0,32
0,40
Weight
Standard version W2 technical
specifications:
Strap, clamps:
1.4510/11 (AISI 430Ti / 439)
Screw: coated steel class 8.8
Nut: coated steel class 8
The PAM-GLOBAL

RAPID NG
coupling, single bolt, allows fast and
reliable installation. SAINT-GOBAIN
PAMs new design ensures optimized
water-tightness and pressure
resistance and better than ever
corrosion resistance.
A wide stainless steel collar allows
tolerance during installation.
Its profile, with edges directed
towards the pipe, encases the
elastomer gasket and prevents any
risk of it being expelled during
tightening. In case of fire, the rubber
gasket is not exposed to flames.
When fully tightened, the coupling
ensures a built-in electrical continuity,
without any added clip.
S
All stainless steel version W5
technical specifications:
Strap, clamps:
1.4404/1.4571
(AISI 316 L/361Ti)
Screw and nut: austenitic
stainless steel A4-70 on AISI 316
DN D
50
70
80
100
125
150
200
70
85
90
125
147
172
223
80
98
103
139
161
187
240
42
42
42
48
56
56
70
185635
207818
207819
185636
207820
207831
185637
Code H L
Max. dimensions after installation
0,10
0,12
0,12
0,18
0,28
0,32
0,40
Weight
DN 250 and DN 300 on request. Recommended for pipe systems exposed to climatic
stresses, i.e rainwater spigot systems, drainage systems for bridges, or open multi-storey
car parks.
The PAM Rapid NG is designed
for a full tightening null gap,
there is no need for checking
the torque.
Specific offer for a complete Nitrile coupling.
For waste water liable to contain hot oil, solvents or hydrocarbons, it is recommended
to use couplings equipped with specific NBR gaskets.
From now on, to meet these special requirements the PAM Rapid NG all stainless
steel W5 coupling alone will be delivered with NBR gasket.
Please ask the complete product codes for couplings with NBR gasket.
INOX
DN 250 and DN 300 on request.
PAM-GLOBAL

Couplings
32
PAM-GLOBAL

CV - CE NG Couplings
DN 50 - DN 300
Standard version technical
specifications:
Collar: Ferritic Stainless Steel -
1.4510/11 or AISI 430Ti/439
Plates: Ferritic Stainless Steel -
1.4373 or 1.4510/11 or AISI
202 or AISI 430Ti/439
Screws: Coated Stell class 8.8
(minimum of 350 h/salt spray test)
All stainless steel version technical
specifications:
Identifying feature: W4
Collar: Austenitic Stainless Steel
1.4301 or AISI 304
Plates: Stainless Steel A2-70 or
1.4301 or AISI 304
Screws: Stainless Steel A2-70 with
coating to avoid seizing
DN
50
70
80
100
125
150
200
250
300
14
14
14
18
18
18
18
18
18
22,5
22,5
22,5
25,5
25,5
25,5
38
38
38
70
90
95
122
147
172
222
287
339
210398
210400
210413
210416
210417
210418
210420
210422
210423
Code
Max. dimensions after installation
0,10
0,12
0,15
0,20
0,30
0,35
0,70
0,85
0,90
Weight
45
48
48
54
54
54
78
78
78
A B D L
DN
50
70
80
100
125
150
200
250
300
14
14
14
18
18
18
18
18
18
22,5
22,5
22,5
25,5
25,5
25,5
38
38
38
70
90
95
122
147
172
222
287
339
185627
207811
207813
185628
207814
207815
207816
207817
185629
Code
Max. dimensions after installation
0,10
0,12
0,15
0,20
0,30
0,35
0,70
0,85
0,90
Weight
45
48
48
54
54
54
78
78
78
A B D L
These two bolts basic couplings are
mostly appreciated because simple
and easy to remove and reinstall
without damage.
The PAM design ensures better than
ever water tightness and pressure
resistance and noticeably improves
corrosion resistance for these couplings.
Tightening torques:
CV Couplings : 8-10 Nm for all DN
CE Couplings : 5-8 Nm for DN 50-75/80
10-12 Nm for DN 100-125
12-15 Nm for DN 150-300
CV
CE
33
PAM-GLOBAL

Couplings
PAM-GLOBAL

GRIP HP COUPLINGS
Two Different Grades
DN
100
125
150
200
250
300
400
500
600
Pressure
Resistance
10
10
10
10
10
10
6
3
2
1,3
1,9
2,1
5,3
8,7
9,9
11,7
12,8
14,1
Weight
S
A2 type
227336
227337
227338
227339
227340
227351
227352
227353
227354
INOX
A4 type
227344
227345
227346
227347
227348
227349
227350
227361
227362
A mm
94
95
95
141
141
141
141
142
144
B mm
45
45
45
60
60
60
60
60
60
D mm
133
158
183
251
305
356
438
557
660
E2 mm
15
15
15
35
35
35
35
35
35
Torque
Nm
20
20
30
50
65
80
80
80
120
Pressure
Resistance
10
10
10
10
10
10
10
6
4
Torque
Nm
20
20
30
30
50
80
90
90
80
For A2 type For A4 type
A2 Type:
Casing : 1.4307
Screws : 1.4301
Barrels : 1.4307
Strengthening plates : 1.4307
Grips : 1.4310
A4 Type:
Casing : 1.4404
Screws : 1.4401
Barrels : 1.4404
Strengthening plates : 1.4404
Grips : 1.4310
Sealing gasket : EPDM and NBR on request
PAM-GLOBAL

FLEX HP COUPLINGS
Two Different Grades
DN
100
125
150
200
250
300
400
500
600
Pressure
Resistance
10
10
10
10
10
10
6
3
2
1,4
1,5
1,7
3,8
4,3
4,7
7,1
6,7
7,6
Weight
S
A2 type
228257
228258
228259
228260
228271
228272
226261
226262
228273
INOX
A4 type
228623
228624
228625
228626
228627
228628
228629
228630
228631
A mm
94
94
94
139
139
139
139
139
139
B mm
45
45
45
86
86
86
86
86
86
D mm
129
152
180
229
294
346
449
551
653
E2 mm
15
15
15
35
35
35
35
35
35
Torque
Nm
10
10
10
20
25
25
25
30
35
Pressure
Resistance
10
10
10
10
10
10
10
6
4
Torque
Nm
10
10
10
20
25
25
25
30
35
For A2 type For A4 type
A2 Type:
Casing : 1.4307
Screws : 1.4301
Barrels : 1.4307
Strengthening plates : 1.4307
A4 Type:
Casing : 1.4404
Screws : 1.4401
Barrels : 1.4404
Strengthening plates : 1.4404
Sealing gasket : EPDM and NBR on request
PAM-GLOBAL

Connectors
34
PAM-GLOBAL

SVE- Coupling
DN 50 - DN 200
Registry No: Z - 42.5-273
Red-coloured, polypropylene double
rubber gasket is supplied with
NR-SBR sealing gaskets.
DN P
[mm]
50
70
80
100
125
150
200
22
22
25
33
32
32
32
88
110
105
145
165
196
252
M 8
M 8
M 8
M 8
M 8
M 8
M 10
221261
221267
221268
220750
221269
221270
221271
Product
Code
D
[mm]
10
10
10
10
10
5
5
L
[mm]
Screw
[mm]
Max. Pressure
[bar]
76
79
78
93
93
102
118
50
80
100
125
150
200
77
103,5
134
161
186
238
60
65,5
82
103
103
114
29
32
39,5
50
50
55,5
2
2
3
3
3
3
180953
180964
180954
180955
180956
180957
DN D L L
1
A Product Code
PAM-GLOBAL

UNIGRIP Collars
DN 50 - DN300
0,45
0,54
0,53
0,90
0,99
1,23
1,72
Weight
0,08
0,11
0,20
0,31
0,38
0,50
Weight
Grips Stainless Steel + Treatment
Frames Galvanised Steel
Tightening plates Galvanised Steel
Screws Coated Steel - Class 8-8
The grip collar is an added
device used to lock the
coupling and ensure both
water tightness and mechanical
stability of the pipework.
The requirements for these
products are very high for
mechanical strength and
pressure resistance.
The stability of the mechanical
performance and the corrosion
resistance of the
PAM-GBLOBAL

UNIGRIP
collar offer extended lifespan
and operation safety over time.
*DN 250 and DN 300 on request.
PAM-GLOBAL

SVE is tested in
compliance with DIN 19543.
It is manufactured in size DN 50
to DN 200 as prescribed by
construction and control regulations.
35
PAM-GLOBAL

Connectors
PAM-GLOBAL

Konfix
For Transition Connections
Registry No: Z - 42.5 - 240
DN D
1
50
70
80
80*
100
125
57
77
82
81
108
132
72
92
92
112
126
151
20
22
22
20
27,5
35,5
155759
155790
180852
179905
155833
155883
Product
Code
D
58
66,5
71,5
88
89,5
108,5
Da
Connecting Pipe
mm
40-56
56-75
56-75
83-90
102-110
125
35
40
45
60
57
65
L
1
L Insert Depth
mm
PAM-GLOBAL

Konfix-Multi
For Multiple Transition Connections
Registry No:. Z - 42.5 - 240
DN D
1
100 108 134 35,5 176811
Product
Code
D
90,5
Da
Connecting Pipe
mm
32-56 40
L
1
L Insert Depth
mm
The Multiquick connector DN
100x70 allows connections
between other materials, with
outside diameter ranking
from 72 to 110 mm, to
PAM-GLOBAL

cast iron
range DN 100 with a
maximum outside diameter of
115 mm.
Several pre-cut options.
Material: EPDM. Clamp made
of chrome steel material
n 1.4016.
PAM-GLOBAL

Multiquick
For Transition Connections Of Various Diameters
Registry No: Z - 42.5 - 240
DN D
1
100x70 117 111 176812
Product
Code
101
To connect up to three
pipes, 32-56 mm, made of
other materials to a cast
iron pipe system DN 100.
Material: EPDM. Clamp made
of chrome steel material n
1.4016.
D
2
D
3
81
D
4
108
d
1
104
d
2
94
d
3
74
d
4
107
H
* For connection to the WC pipes and fittings in 90 mm diameter
0,11
0,20
0,16
0,17
0,30
0,64
Weight
0,32
Weight
0,15
Weight
Transitional connectors DN 50-
125 are devoted to connecting
cast iron ranges S and Plus to
other materials, be they steel
or plastic.
The connections with these flexible
connectors are easy and safe:
one pre-cut lid and a lip seal
inside (see figure).
Material: EPDM. Clamp made of
chrome steel material n 1.4016.
DN50
DN75
DN100
DN125
DN150
DN200
DN250
DN300
DN400
DN500
DN600
Pipe cutter Powered disc cutter Band saw
S range
Hacksaw
PAM-GLOBAL

Application Guide
36
Simple Installation
With Greatest
Accuracy
PAM-GLOBAL

pipes up to DN
300 are generally supplied in
3 m length which can be cut to
length.
Where the pipes are cut on
site, they should be cut clean
and square and burrs removed.
Cut ends should be re-coated
with the EXTREM 1 one
component touch-up paint.
Installation Instructions
For PAM-GLOBAL

RAPID Coupling
1. Push the supplied
assembled coupling onto the
pipe spigot up to the middle
spacing ring of the seal.
2. Push the next pipe spigot
into the other end of the
coupling.
3. Tighten the screw to null
gap position, completely
closed, with a ratchet spanner
or an electric screwdriver
PAM-GLOBAL

pipes can be readily cut by the use of a powered disc-cutter, or with wheel cutter.
Ensure correct grade of disc appropriate to cast iron are used, and that cutting wheels or saw blades are changed on
a regular basis. Angle grinders are not advisable for cast iron, but should they be used, make sure a secure hold of
the pipe is made. Warning: Chain cutters or snap cutters should not be used to serve the purpose
Cutting Techniques
The pipe cutter from Ridgid or Rothenberger (see above) ensure fast, neat and square cutting.
Reciprocating saw can be used but is not so well adapted.
37
PAM-GLOBAL

Application Guide
Suspended pipe works shall
be secured with fix points
every 10 or 15 meters so
to prevent disconnection.
On vertical runs, waste
water or rainwater
downpipes, the bracketing
aims at preventing the
pipework to fall over due
to its own load.
The downpipes shall
likewise be secured by two
brackets spaced no more
than 2 m, including one in
the immediate vicinity of a
branch.
To address both pipe load
and end thrust force, a
stack installed through open
hoppers must be secured
with fix points-like stack
supports-to prevent the pipe
works from falling over.
For buildings up to 5
storeys and a pipe diameter
DN 100, we recommend
to position the first stack
support pipe at the base of
the first floor, and then
every subsequent fifth floor,
in case of a standard
average 2.5 m between
floors, or more generally
every 15 m. The pipe work
illustrated here indicates
the basic support and
bracketing rules.
PAM-GLOBAL

includes a
comprehensive range of
clamps and accessories to
secure your cast iron
pipeworks.
These accessories are
available in 3 sizes to
match different load levels.
For further technical details
please contact us.
PAM-GLOBAL

lines
experiencing pressure: Non
gripped waste-water pipes
subject to internal pressure
loads must be secured so
that they do not undergo
dislocating forces are not
pushed out of axial
alignment.
The adequate longitudinal
frictional connection can
be achieved with
PAM-GLOBAL

grip collars.
Please contact us for details.
PAM-GLOBAL

Bracketing
recommendations for
cast iron pipe works.
Pipework stability
A pipework is submitted to
different forces liable to
affect its stability; for cast
iron, the bracketing system
is designed to carry only
the weight of the pipe and
its content (see table 1 on
page 19).
The bracketing rules aim at
keeping the pipeworks
stable, based on the pipe
loads. Pipe supports and
fixings shall be adapted
accordingly .
Basic rules: The pipes
brackets should be
regularly spaced and the
distance between two
brackets should generally
not exceed 2m.
The pipes of 2 or 3 m
length should be supported
with two brackets. Shorter
pipe lengths should be fixed
with one or two brackets,
depending on the diameter
(or pipe load).
The brackets should be
uniformly spaced in relation
to the junctions between
two elements. The distance
on either side of a coupling
should not be longer than
0.75 m.
Horizontal runs must be
adequately secured at
changes of direction and
wherever a fitting is
installed.
PAM-GLOBAL

Cast Iron Pipe


Downpipe
support
Side View
Top View
All dimensions
are in mm
PAM-GLOBAL

Syphonic Roof Drainage System


38
39
PAM-GLOBAL

Syphonic Roof Drainage System


PAM-GLOBAL

EPAMS

Syphonic Roof Drainage System


The EPAMS

high-capacity
syphonic roof drainage system
was developed approximately 35
years ago in Scandinavia. It is
mainly used for draining roofs
with large surface areas, such as
factories, storage facilities,
shopping centres, as well as
buildings used for sports, leisure,
transportation and administration.
The EPAMS

system is a
technically mature development
in roof drainage. It complies with
the DIN 1986-100 (version: May
2008). Meanwhile, pressure-flow
roof syphonic systems, laid within
the PAM-GLOBAL

S pipe system,
are being used by thousands in
Germany.
The EPAMS

roof drainage system


has been taken into account by
Part 1 since 1988 and Part 2
since 1995. In traditional
rainwater drainage systems, after
the rain falls to the roof, it flows
to the roof outlet or gutter via
partially-filled drainage pipes.
Inside buildings, the maximum fill
factor in rain water pipes is 0.7
(h/d = 0.7) according to EN
12056. This fill factor means that
traditional rainwater drainage
systems must have adequate pipe
ventilation.
Traditional flat roof outlets form
water eddies and cones of air.
The undesired air infeed is affected
by the Coriolis force (eddy
forming) and also depends on the
atmospheric pressure, gravity and
the Earth's rotation.
The air in the middle of the outlet
is sucked in through the eddies.
This lowers the outlet's capacity
level.
In contrast to open channel
drainage (according to EN
12056), pressure-flow roof
drainage pipes systematically
operate at the designed rain yield
factor. When the pipe system has
reached maximum capacity, the
geodetic height difference between
the roof outlet and the transition
pipe is used in open channel
drainage in order to overcome
flow loss. This is why smaller
dimensions are required than in
open channel drainage systems.
The pipes can be laid without
gradients under the roof
construction due to the typical
operating conditions of these
systems.
There is no need for a wide-spread
branched pipe network. As a rule,
our EPAMS

high capacity roof


drainage system, with all of its
benefits and advantages, offers
extremely economical solutions.
However, the pipes can only reach
maximum capacity using specially
designed roof or channel outlets,
which prevent air infeed into the
pipe when the calculated volume
of rainwater has been reached.
With the EPAMS

system the air


is prevented from flowing (air cone
buildup) into the pipes when the
calculated rain volume has been
reached.
The applicable regulation for the
calculation of pipe sections for
rainwater drainage is EN 12056.
However, the syphonic drainage
system as a possibility for roof
drainage is merely mentioned
here. Further details on the design
and construction of such drainage
systems are not provided. This is
why the DIN 1986-100 has
universal validity. This directive
sets out guidelines for planning,
calculation and construction, while
the corresponding system
components of individual
manufacturers have fundamental
distinctions with regards to
assembly and mounting directives.
Conventional
System
How the
EPAMS

outlet
functions
For additional information, please ask for a brochure.
PAM-GLOBAL

Syphonic Rainwater Drainage System


40
Advantages of PAM-GLOBAL

Roof Drainage System


Conventional Rainwater Drainage
DN100 DN100 DN100 DN100
PAM-GLOBAL

EPAMS

System
DN 50 DN 80
DN 100
Pipes can be laid without
gradients
High flow rate enables
self-cleaning
Pipe dimensions significantly
reduced
Limited number of pipe
trenches, shafts or buried pipes
Easier installation shortens
construction time
Slab can be cast immediately
Lower insulation costs
through smaller pipe
dimensions
Structural suspended
ceiling height can be
reduced
Skirting protection savings
thanks to fewer downpipes
Price advantage gained by
lower material and labor
costs
PAM-GLOBAL

UNO 24/DN 80 Stainless Steel Flat-Roof Outlet


Available as one or two component models, stainless steel
Material no: 1.4301, with flanges
Capacity:
Up to 24 l/s
Accessories:
Galvanized steel connector flange, 600x800 mm
(for trapezoidal sheet metal roof)
Stainless steel connector flange
as a loose and fixed flange combination, 325 mm
(for concrete roof)
Inspection chamber (for inverted or landscaped roofs, where
allowed by local regulations)
Heating strip, PUR 10 Watt, 230 V
Roof Outlets (In Compliance With DIN EN 1253)
41
PAM-GLOBAL

Syphonic Rainwater Drainage System


HDE gutter outlets DN 50, special production DN 70
Rounded design, aluminium, copper and stainless steel A4,
material 1.4571, stainless steel outlets also available with
connector flanges.
All run-offs with leaf traps and reinforced outlet supports.
Capacity:
Up to 4 l/s (DN 50)
Up to 8 l/s (DN 80)
PAM-GLOBAL

Gutter Outlet
Available in one or two component models, cast iron
Capacity:
Up to 24 l/s (DN 80)
Accessories:
Insulating bodies made of cellular glass for thermal insulation
Heating strip, 20 Watt, 230 V
PAM-GLOBAL

INO-
GGG Flat-Roof Outlet
In Cast Iron
Available as one or two component models,
stainless steel
Material no: 1.4301, with flanges
Capacity:
1 l/s to 5 l/s (DN50)
1 l/s to 8 l/s (DN80)
PAM-GLOBAL

UNO 24
Stainless Steel Outlet-
Edge Gated Horizontal
Connection
Airports
A380 Maintenance Hangar / Airport
(Germany)
Airport Terminal (Germany)
Airports Vnukovo and Sheremetyevo 3
(Russia)
Domodedowo Airport (Russia)
Frankfurt Airport (Germany)
Tour A, Luxembourg/Kirchberg
(Luxemburg)
42
REFERENCES
Bridges
Beverbach Talbrcke / bridge (Germany)
Bridge Krshegy (Hungary)
Theistalbrcke / bridge (Germany)
Zoobrcke Kln / bridge (Germany)
Commercial and Admin. Build.
Ak MerkezShopping Center (Turkey)
ARBED (ARCELOR) Administrative Building
(Luxemburg)
Arcades Mall Center (Hungary)
Auchan commercial center (Russia)
Auchan Commercial Center, Luxembourg
(Luxemburg)
Banque d'Investissement Europenne,
Luxembourg (Luxemburg)
Bayrische Landesbank, Luxembourg
(Luxemburg)
BMW - World (Germany)
Business Center Diplomat Hall (Ukraine)
Business Center Strassen (Luxemburg)
Business Park Sofia (Bulgaria)
Business Park Varna (Bulgaria)
Casper Business Center (Turkey)
CK Business Center Leudelange (Luxemburg)
Dedeman Hotel and Shopping Mall (Turkey)
Dunajski Mozaik Commercial Centre
(Slovenia)
Exhibition Center (Germany)
Forum Shopping Mall (Turkey)
Gazpron Tower (Russia)
General Post Office (Germany)
Gimat Shopping Mall (Turkey)
IKEA Mega-Mall Rostov/Don Moscow,
Ekaterienburg (Russia)
IKEA Mega-Mall St. Petersburg, Novosibirsk,
Krasnodar, Perm (Russia)
Kanyon Shopping Mall and Residentials
(Turkey)
Kursker Railway station Shopping Center
(Russia)
Office Surgutneftgaz (Russia)
Office UralSib (Russia)
Petrovsky Passage (Russia)
Sabanci Centre (Turkey)
Shopping Center Kln Arkaden
(Germany)
Shopping Center City Park (Slovenia)
Shopping Center Phoenix Center (Germany)
Hospitals
Hospital Samara (Russia)
Moscow Hospital (Russia)
Novokutsnesk Hospital - Siberia (Russia)
Oncological Clinic (Russia)
Reko Hospital (Russia)
Hotels
2 Hilton Hotels (Turkey)
Club Mediterannee (Turkey)
Elysee Hotel (Germany)
Falez Hotel (Turkey)
Grand Hotel Mariott (Russia)
Hilton Hotel (Turkey), (Ukraine)
Hilton Hotel (Turkey)
Holiday Inn (Turkey)
Hotel Premier Palast (Ukraine)
Hotel Corinthia (Russia)
Hotel Hilton (Azerbaidjan)
Hotel Ritz Carlton (Russia)
Hotel Svjosdny (Russia)
Hotel Theatralnaya (Ukraine)
Hyatt Regency Hotel (Turkey)
Kempiski Ciragan Hotel (Turkey)
Kosmos Hotel (Russia)
Mariottt Hotel (Turkey)
Movenpick Radisson Hotel (Turkey)
Penta Lufthansa Hotel (Turkey)
Pierre Loti Hotel (Turkey)
Raddisson SAS Royal Hotel (Russia)
Ramada Inn Crowne Plaza (Turkey)
Sheraton Hotel (Turkey), (Turkey)
Swiss Hotel Bosphorus (Turkey)
Yalta Hotel (Russia)
43
Productions Sites
Audi cars Works (Germany)
Cadburys Factory (Russia)
Eon RWE Energiezentralen (Netherlands)
Factory Tetra Pack Lobny ( Moscow region) (Russia)
Factory General Motors (Russia)
Factory Volkswagen (Russia)
Perfetti van Melle Sweet Factory (Netherlands)
Porsche Cars (Germany)
Renault Factory (Turkey)
Technology Park (Slovenia)
Public Buildings
Administration Building of Luxembourg County (Luxemburg)
Centre Socio-Culturel, Luxembourg (Luxemburg)
Chambre of Commerce (Luxemburg)
Cours des Comptes Europenne (Luxemburg)
European Community Conference Center (Luxemburg)
German Embassy (Russia)
Latvian National Library (Latvia)
Metro Line (Turkey)
N.A.T.O. Bases (Turkey)
Palais de Justice de Paix, Esch/Alzette (Luxemburg)
Parliament and Government Building (Germany)
Parliament Building (Hungary)
Philharmonie Music Hall (Luxemburg)
Railway Station "Lehrter Bahnhof" (Germany)
Railway Station Central (Ukraine)
Rijaset Islamske Zajednice (Bosnia)
Sabanci University (Turkey)
Youth Centre Astana (Kazakhstan)
Residential Build.
Baranovitchi Military Housing (Russia)
Baytur Residentiazl Buildings (Turkey)
Housing Panorama Plaza (Latvia)
Housing complex Begowaya, Kutusov Riviera, MIRAX-Park" (Russia)
Housing complex Jantarny Gorod (Russia)
Mashattan Towers (Turkey)
Moscow City, pilot 13, Federation Tower A (Russia)
Moscow City, pilot 4, Imperia Tower (Russia)
Moscow City, pilot 9, Gorod Stolitz, High Rise Building (Russia)
Slonim Military Housing (Russia)
Vila Urbana (Slovenia)
Stadiums
Ice Arena (Russia)
Olimpia Stadium (Turkey)
Olympic Sport Center (Latvia)
Olympic Stadium (Ukraine)
Schalke-Arena Stadium (Germany)
StadiumAllianz-Arena (Germany)
Fire resistant, durable, long-lasting, silent and
low-maintenance PAM-GLOBAL

cast iron drainage pipes are the worlds number


one choice for wide-ranging areas of usage.
Business Centers / Car Parkings
Hotels / Residential Buildings
Public Buildings / Shopping Malls
Hospitals / Manufacturing Plants
Schools / Gymnasiums and stadiums
Cast I ron Drai nage Syst ems
J
a
n
u
a
r
y

2
0
1
2
Saint-Gobain HES GmbH
Ettore-Bugatti-Str. 35 - D-51149
Kln/Porz-Gremberghoven - Germany
Central Office: +49 2203 9784-0
Sales: +49 2203 9784-300
Technical Support: +49 2203 9784-310
Fax: +49 2203 9784-200
E-mail: info@hes.saint-gobain.com
Web: www.saint-gobain-hes.de
Central Stock: Saint-Gobain HES GmbH.
Wanner Str. 172 45888 Gelsenkirchen - Germany