EPLAN Training 1

Connection Numbering
Connection Numbering
EPLAN Training 2


1 Specifying Settings for Connection Numbering ........................................3
2 Creating Format Groups ..............................................................................7
3 Editing Format Groups...............................................................................11
3.1 Delete format groups ..............................................................................15
4 Defining Net Extensions.............................................................................18
5 Placing Connection Definition Points.......................................................21
6 Designating Connections...........................................................................22
6.1 Change numbering results......................................................................24
7 Realigning and Formatting Connection Designations ............................27
8 Deleting Connection Designations............................................................30

This functionality is only available for certain module packages. Info
Connection Numbering
EPLAN Training 3

1 Specifying Settings for Connection Numbering
Settings for connection numbering are saved in schemes. This way you can access
previously specified settings at any time and even change them, if necessary.
Precondition:
You have opened a project.
Project data > Connections > Numbering > Settings
1. In the Settings: Connection numbering dialog, select a user-defined
scheme from the drop-down list, or create a new scheme using (New).

2. In the Filter tab select the check box for the trade and connection type you
want to number.

Connection Numbering
EPLAN Training 4

3. In the Placement tab select where and how often you want to place the
connection definition points on the connections.

Connection Numbering
EPLAN Training 5

4. In the Designation tab, define the format groups that are to be formatted
together.

Connection Numbering
EPLAN Training 6

5. In the Display tab specify formatting for connection designations generated on
the connection definition point. Among these formatting options are, for
example, horizontal and vertical increments of the connection designation from
the connection line, as well as text color, size, etc.

6. Click [OK].

The scheme is now set up and will be used when you are numbering
connections.

This functionality is only available for certain module packages. Info
Connection Numbering
EPLAN Training 7

2 Creating Format Groups
Precondition:
You have opened a project.
Project data > Connections > Numbering > Settings
1. In the Settings: Connection numbering dialog, select a user-defined
scheme from the drop-down list, or create a new scheme using (New).

Connection Numbering
EPLAN Training 8

2. Move the Designation tab to the foreground and in the toolbar above the
Format groups field, click (New).

Connection Numbering
EPLAN Training 9

3. In the Connection numbering: Formats dialog, in the Connection group
field, select one of the predefined connection groups or the "Browse..." entry.

4. If you selected "Browse..." and opened the Device tag list dialog, select one
of the DT's in the project and click [OK].

5. In the Extent field specify the range of connections that are to receive the
same format for their connection designations. Select an entry from the drop-
down list.
Note:
If you have selected the "Net" entry, you can use the net extension to expand
the area of influence for numbering.
6.
7. In the Available format elements field select a format element and move it
over to the right using the arrow button into the list of selected format
elements.

Connection Numbering
EPLAN Training 10

Different subsequent dialogs will appear, depending on the formatting
element. Depending on the format element selected, this can be one of the
following dialogs: Format: Properties, Format: Counter, Format: Page / column
/ row or Format: Separator.

8. Define the formatting in the subsequent dialog.

In the Preview field, a preview of the designation format is displayed. The
individual formatting elements are displayed in the connection designations in
the same sequence as they currently exist in the list.

9. If desired, you can change the sequence of the formatting elements using the
arrow buttons.

10. Click [OK].

The values entered will be saved in the selected scheme.

This functionality is only available for certain module packages. Info
Connection Numbering
EPLAN Training 11

3 Editing Format Groups
Precondition:
You have opened a project.
Project data > Connections > Numbering > Settings
1. In the Settings: Connection numbering dialog, select the Designation tab.

2. In the Format groups field select a format group and click (Edit).

Connection Numbering
EPLAN Training 12

3. In the Connection numbering: Formats dialog in the Extent field, change if
necessary, the range of connections that are to receive the same format for
their connection designations. Select an entry from the drop-down list.
Note:
If you have selected the "Net" entry, you can use the net extension to expand
the area of influence for numbering.
Connection Numbering
EPLAN Training 13

4.
5. In the Selected format elements field select an entry and click (Edit) to
change the formatting. Or, in the Available format elements field select a
format element and move it over to the right using the arrow button into the list
of selected format elements in order to define an additional format element.

Different subsequent dialogs will appear, depending on the formatting
element.
Connection Numbering
EPLAN Training 14


Connection Numbering
EPLAN Training 15

6. In the subsequent dialog (Format: Properties, Format: Counter, Format:
Page / column / row or Format: Separator) define the desired formatting.

In the Preview field, a preview of the designation format is displayed. The
individual formatting elements are displayed in the connection designations in
the same sequence as they currently exist in the list.

7. If desired, you can change the sequence of the formatting elements using the
arrow buttons.

8. Click [OK].

The changed values entered will be saved in the selected scheme.

3.1 Delete format groups
Precondition:
You have opened a project.
Connection Numbering
EPLAN Training 16

Project data > Connections > Numbering > Settings
1. In the Settings: Connection numbering dialog, select the Designation tab.

Connection Numbering
EPLAN Training 17

2. In the Format groups field select a format group and click (Delete).

The format group is deleted.

This functionality is only available for certain module packages. Info
Connection Numbering
EPLAN Training 18

4 Defining Net Extensions
In the Net extension dialog you can add to a net definition. This setting affects the
designation if the range is selected as "Net". Typically a net ends at item terminals
and connection points. Use the net extension function to expand the net with
terminals and plugs.
Precondition:
You have opened a project.
Project data > Connections > Numbering > Settings
1. In the Settings: Connection numbering dialog, select a user-defined
scheme from the drop-down list, or create a new scheme using (New).

Connection Numbering
EPLAN Training 19

2. Select the Designation tab and click [Net extension].

Connection Numbering
EPLAN Training 20

3. In the Net extension dialog use the arrow button to move the desired
functions from the Selection list into the Net extended with following
objects list.

The net will then no longer end at the selected functions, but rather it will be
extended by them.

The net extension applies to all format groups contained in the "Net" scope.

4. Click [OK].

The setting will be saved in the selected scheme.

This functionality is only available for certain module packages. Info
Connection Numbering
EPLAN Training 21

5 Placing Connection Definition Points
Precondition:
You have selected connections in the graphical editor, or you have selected one or
more pages or a project in the Pages - <Project name> navigator dialog.
Project data > Connections > Numbering > Place
Once you have called up the menu item, the connections are first automatically
newly generated.
1. In the Settings field of the Place connection definition points dialog select
a scheme from the drop-down list that will specify the settings for connection
numbering. Click [...] to open the Settings: Connection numbering dialog.
Define the numbering settings here and store them in a scheme.

2. Activate the check box Apply to entire project in order to extend the
connection numbering for the entire project. If you have called up the dialog for
a selected project from the Pages - <Project name> navigator dialog, the
check box is already selected and grayed out.

3. Click [OK].

The connection definition points are placed on the schematic pages. They
receive "????" as a designation if the associated connection still has no
designation.

This functionality is only available for certain module packages. Info
Connection Numbering
EPLAN Training 22

6 Designating Connections
Via the Designate connections dialog you can designate those connection definition
points that are able to possess a connection designation.
Connection designations are assigned using connection definition points. A
connection can only be designated if all of its connection definition points are
selected. If a page is open in the graphical editor you can individually select the
definition points. Otherwise they are selected via the pages or the project. If the
connection has definition points that are not selected, it cannot be designated.
Precondition:
You have selected connections in the graphical editor, or you have selected one or
more pages or a project in the Pages - <Project name> navigator dialog.
Project data > Connections > Numbering > Enter designation
Once you have called up the menu item, the connections are first automatically
newly generated.
Connection Numbering
EPLAN Training 23

1. In the Settings field of the Designate connections dialog select a scheme
from the drop-down list that will specify the settings for connection numbering.
Click [...] to open the Settings: Connection numbering dialog. Define the
numbering settings here and store them in a scheme.

2. In the table specify the start value and the increment for numbering each
displayed connection group.

3. In the Overwrite group box specify the connection definition points for which
the designation should be overwritten.

4. Select the Mark as "manually set" check box to assign the "Manually set"
property to all connection definition points for which a connection designation
is set during this numbering process.

5. Activate the check box Apply to entire project in order to extend the
connection numbering for the entire project. If you have called up the dialog for
Connection Numbering
EPLAN Training 24

a selected project from the Pages - <Project name> navigator dialog, the
check box is already selected and grayed out.

6. Select the Preview of result check box so that before the new connection
designations are adopted, the Designate connections: Preview of result
dialog is displayed.

7. Click [OK].

The connection designations are displayed on the connections that are
selected for the numbering, as long as the connection definition points have
been placed there.

6.1 Change numbering results
In the Designate connections: Preview of result dialog, the connections whose
designations are to be changed are listed. You can confirm the acceptance of the
new connection designations, abort, or manually modify the new designations.
Precondition:
You have selected connections in the graphical editor, or you have selected one or
more pages or a project in the Pages - <Project name> navigator dialog.
Project data > Connections > Numbering > Enter designation
Connection Numbering
EPLAN Training 25

1. In the Designate connections dialog specify the settings for connection
designations and select the Preview of result check box.

2. Click [OK].

3. In the Designate connections: Preview of result dialog, browse through the
table and, if necessary, change the connection designation in the New
connection designation field.

4. Select Popup menu > Keep old connection designations if you would like
to enter the old connection designation in the New connection designation
field for the selected connection.

5. Click [OK].

The connection designations are displayed on the connections that are
Connection Numbering
EPLAN Training 26

selected for the numbering, as long as the connection definition points have
been placed there.

This functionality is only available for certain module packages. Info
Connection Numbering
EPLAN Training 27

7 Realigning and Formatting Connection
Designations
Use the Realign and reformat command to reset the original positions of any
connection definition points that were already set but were later moved / reformatted.
In doing so, the original formatting specified in the settings will be restored for the
selected connection definition points.
Precondition:
You have selected connections in the graphical editor, or you have selected one or
more pages or a project in the Pages - <Project name> navigator dialog.
Project data > Connections > Numbering > Realign and reformat
Once you have called up the menu item, the connections are first automatically
newly generated.
Connection Numbering
EPLAN Training 28

1. In the Settings field of the Align and Format Connection Designations
dialog select a scheme from the drop-down list that will specify the settings for
connection numbering. Click [...] to open the Settings: Connection
numbering dialog. Define the numbering settings here and store them in a
scheme.

2. In the Connection definition points group box specify which connection
definition points should be realigned and formatted.

3. Select the Retain "manually set" numberings check box to retain the
alignment and formatting for connection definition points with the "Manually
set" setting.

4. Activate the check box Apply to entire project in order to extend the
connection numbering for the entire project. If you have called up the dialog for
Connection Numbering
EPLAN Training 29

a selected project from the Pages - <Project name> navigator dialog, the
check box is already selected and grayed out.

5. Click [OK].

Connection definition points will be realigned and formatted.

This functionality is only available for certain module packages. Info
Connection Numbering
EPLAN Training 30

8 Deleting Connection Designations
Precondition:
You have selected a connection in the graphical editor, or in the Connections -
<Project name> navigator dialog. Or you have selected one or more pages or a
project in the Pages - <Project name> navigator dialog.
Project data > Connections > Numbering > Delete
Once you have called up the menu item, the connections are first automatically
newly generated.
1. Select a scheme from the drop-down list in the Settings field of the Delete
connection designations dialog.

The filter settings defined in this scheme are taken into account when
deleting the connection designations.

2. If you wish to change the filter settings, click [...] next to the Settings field.

3. Define the desired filter settings using the Settings: Connection numbering
dialog. Select the appropriate check boxes for the desired connection types
and click [OK].

Connection Numbering
EPLAN Training 31

4. In the Delete connection designations dialog use the radio buttons to
specify whether you only want to delete the connection designations or also
the empty connection definition points.

5. Select the Retain "manually set" check box to retain the alignment and
formatting for connection definition points with the "Manually set" setting, to
not delete them, and to retain their designation.

6. Select the check box Apply to entire project in order to extend the deletion to
the entire project.

7. Click [OK].

According to the settings, the connection designations and if selected
the empty connection definition points will be deleted from the project.