Sie sind auf Seite 1von 76

Dear Valued Customer:

Multilink is excited about the coming year ahead because of the people we have working to
better service our customers’ needs. We will focus on keeping cost under control, maintaining
quality standards, continuing product reliability, providing on-time delivery, and meeting our
customers’ market-specific needs.

Some people say that your environment is a reflection of your experiences. Multilink has been
able to understand where we fit in your environment with manufacturing cost effective solutions
and technicians that make your job more productive when servicing your customers needs.

Listing your needs in a step-by-step way insures Multilink that we have created the right fit
between our product and customer. We hope that if our organization is not serving you to our
best ability that you give me a call at 440.366.6966.

Sincerely,
Steve E. Kaplan
CEO

Customers do make the difference

2 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:2 Sec1:2 6/6/2007 12:43:24 PM


Our environment is a reflection of our experiences in servicing our many
customers worldwide that have helped Multilink better understand the
many needs that have put Multilink products to work in the field since 1983.

Multilink Broadband Network Powering Products For Outside Plant 3

MULTILINK POWER SOURCE CATALOG.iSec1:3 Sec1:3 6/6/2007 12:43:27 PM


Since 1983
Manufacturing and R&D Facilities:
Elyria, Middlefield and North Lima-Ohio.
Worldwide Sales Support Manufacturing
S/B ISO 9001:2000/TL9000 CERTIFIED
Multilink’s uncompromising commitment to product reliability and customer
support in controlling all details and processes from sheet metal, circuit boards,
plastic injection molding and plastic extrusions.

4 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:4 Sec1:4 6/6/2007 12:43:34 PM


Multilink Broadband Network Powering Products For Outside Plant 5

MULTILINK POWER SOURCE CATALOG.iSec1:5 Sec1:5 6/6/2007 12:43:40 PM


PATENTS & INNOVATIONS
2007
Introduction Of Bluetooth Technology For Status Monitoring
First Web Video Installation Training For Fusion Splicing Training
First Web Video Installation Instruction Training For Power Supply
FTTx Fiber Optic Slack Storage Enclosure
FTTx Overlay Molding For Existing Molding
FTTx Exterior Fiber Optic Slack Storage Enclosure
2005
Drop Fiber Sno-Shoe - Pat# D450,042S
Mulitpath Pavement Duct System
5 Amp Min. Stand By Power Supply
Direct Core Cooling
Open Face Molding
2004
Compression Seal Technology Dome Enclosure
Tech Bag For Handling Converters
2002
Communication Cable Clip - Pat# 6,378,814 B1
2001
Battery Power Supply Source Of Uninterruptible Power Supply - Pat# 6,268,665 B1
2000
Release Of 1st Airflow Power Supply Cabinet - Pat# 6,932443 B1
1999
Patented The 1st UPS With Polarity Of Inverters CCP Tech - Pat# 5,994,793
1998
Fiber Optic Splice Case - Pat# 5,732,180
1997
First Cable Identification Tag - Pat# 387,811
1993
Patented And Trademarked First Plastic Sno-Shoe - Pat# 5,408,571
Architectural Cove Molding For Housing Cable Wires - Pat# D332,941
1992
Patented First Low Cost Torque Wrench - Pat# 5,152,200
1991
Patented Coring And Stripping Tool For Dielectric Cable - Pat# 5,023,995

6 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:6 Sec1:6 6/6/2007 12:43:47 PM


Contents
COMPANY............................................................. 2
MULTILINK SERVICES...................................................... 8
BLACK HAWK POWER SUPPLY......................................... 9
BLACK HAWK INTERFACES............................................. 15
CO M M O N F E R R O C H A R T. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16
LIT TLE HAWK POWER SUPPLY.............................. 18
MP PLUS POWER SUPPLY .................................... 20
CONFLUENT POWER.................................................. .... 24
N S - N O N - S TAN D BY / S E R V I C E S U P P LY. . . . . . . . . . . . . . . . . . 26
BAT TERY BALANCE MANAGER............................. 28
BAT TERIES.......................................................... 30
POLE MOUNT POWER SUPPLY ENCLOSURES............. 33
GROUND MOUNT POWER SUPPLY ENCLOSURES........ 35
LIFE SAVER TECHNOLOGY ENCLOSURES.............. 37
GROUND MOUNT LIFE SAVER ENCLOSURES................ 38
POLE MOUNT LIFE SAVER ENCLOSURES................... 40
METERED POWER SUPPLY ENCLOSURES..................... 43
CUSTOM METERED POWER SUPPLY CABINETS.......... 45
NON-STANDBY PEDESTALS........................................ 46
BATTERY ENCLOSURES................................................ 47
STANDBY GENERATOR................................................ 50
SURGE SUPPRESSION................................................. 52
SURGE PROTECTION.............................................. 55
POWER CABINET ACCESSORIES & OPTIONS.............. 56
OPTO ELEC TRONIC ENCLOSURES......................... 57
R ACK MOUNT FAN SHELF.................................... 57
ABOVE GROUND CABINETS.................................... 58
UNDERGROUND VAULTS & BAT TERY VAULTS ........ 61
DRY BOX ............................................................ 62
MQ SERIES CABINETS............................................ 64
MQ SERIES CABINETS LOW PROFILE........................ 66
MQ & SMARTPED CABINET OPTIONS....................... 74

Multilink Broadband Network Powering Products For Outside Plant 7

MULTILINK POWER SOURCE CATALOG.iSec1:7 Sec1:7 6/6/2007 12:43:54 PM


Multilink Service Programs
Support - 24.7.365
Track Repairs Online - 24.7.365

MULTILINK SERVICE PROGRAMS


We offer a broad range of customer support in the field where
you need it most. Multilink offers additional services to provide
our customers or their contractors with: Training, Power Design, Site Selections,
Permitting, Easement Acquisition, Contractor Coordination, Basic Installation, Turn On
And Validation, Preventative Maintenance and Complete Turnkey Installation.

MULTILINK SERVICE CENTERS


We offer full warranty and non-warranty
repair services for MP and Black Hawk
series power supplies by factory-trained
technicians.

MULTILINK FIELD SERVICE ENGINEERS


We are available for emergency repair
and technical service.

MULTILINK IMMEDIATE TECHNICAL SUPPORT


We are available at 440.366.6966. Or log onto our
web site: www.multilinkone.com, and
visit our Product Section”.

VIDEO
View an Installation Video.
Now you have round-the-clock
installation training for your
Power Maintenance Staff 24.7.365.
Just go to www.multilinkone.com.

8 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:8 Sec1:8 6/6/2007 12:43:57 PM


. BLACK HAWK POWER SUPPLY .

Premium Standby Power Supply

Forward Thinkers replace old stand-by power supplies


with state of the art VoIP reliability refinements

Optional BluetoothTM wireless local access to power supply performance and status up to 100’ away.
Bluetooth is a registered trademark of Bluetooth SIG, Inc., USA

Multilink Broadband Network Powering Products For Outside Plant 

MULTILINK POWER SOURCE CATALOG 99 9 12/5/2007 12:35:17 AM


VoIP Ready
Premium Uninterruptible Power
Fast uninterruptible transfer output in 500, 900, 1350 and 2000VA ratings.
Direct Core Cooling
Channels cooling air directly to the source of heat, eliminating hot spots and improves efficiency.
Does not circulate hot air through the power supply.
Lower Battery Ripple
Carefully selected inverter components reduce inverter input ripple, improving reliability and
increasing efficiency.
Inverter Current Limiting
Each inverter-switching component is individually protected thereby, improving reliability.
Modern PCB Assembly Process
Automated surface mount technology increases consistency and reliability.
Status-at-a-Glance
Simple LED display instantly shows power supply status. No need for an LCD display with
complex menus.
Conformal Coated Circuit Boards Optional
24 hour burn-in time before shipping.

The key feature that


Modern PCB puts Black Hawk on
Assembly Process the cutting edge
Black Hawk Inverter

Status at
a Glance

Low Battery
Ripple

Transfer relay
tested to
1,000,000
Direct Core operations
Cooling

PENDING AGENCY APPROVAL

10 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG 910 10 12/5/2007 12:35:18 AM


. BLACK HAWK POWER SUPPLY .

Replaceable Transfer Relay

Resetable Output
Circuit Breaker
No Fuses To Replace

30A Contact Rating


Easy Access Socket Design
Allows For FAST Field Replacement

PATENT PENDING

Multilink Broadband Network Powering Products For Outside Plant 11

MULTILINK POWER SOURCE CATALOG.iSec1:11 Sec1:11 6/6/2007 12:44:13 PM


Air Flow Cooling Duct

COOL AIR FLOWS directly to where


it is needed and then out the
back of the power supply

Enclosed
Cooling Duct

12 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:12 Sec1:12 6/6/2007 12:44:18 PM


. BLACK HAWK POWER SUPPLY .
Nominal Specifications for 600, 900, 1350 and 2000 VA Power Supplies
Nominal Input Input Output Output Max Output Battery Approximate
Part # Model Description Voltage VAC Frequency Hz Voltage VAC Current A Power VA Voltage VDC Weight lbs/kg
017-028-20 BLACK HAWK 900-120/60-36 120 60 60/75/90 15/12/10 900 36 62/28.1
017-028-21 BLACK HAWK 900-120/60-48 120 60 60/75/90 15/12/10 900 48 62/28.1
017-028-22 BLACK HAWK 900-240/60-36 240 60 60/75/90 15/12/10 900 36 62/28.1
017-028-23 BLACK HAWK 900-240/60-48 240 60 60/75/90 15/12/10 900 48 62/28.1
017-030-20 BLACK HAWK 1350-120/60-36 120 60 60/75/90 22/18/15 1350 36 69.5/31.5
017-030-21 BLACK HAWK 1350-120/60-48 120 60 60/75/90 22/18/15 1350 48 69.5/31.5
017-030-22 BLACK HAWK 1350-240/60-36 240 60 60/75/90 22/18/15 1350 36 69.5/31.5
017-030-23 BLACK HAWK 1350-240/60-48 240 60 60/75/90 22/18/15 1350 48 69.5/31.5
017-032-20 BLACK HAWK 900-100/50-36 100 50 60/75/90 15/12/10 900 36 72/32.7
017-032-21 BLACK HAWK 900-100/50-48 100 50 60/75/90 15/12/10 900 48 72/32.7
017-033-20 BLACK HAWK 1350-100/50-36 100 50 60/75/90 22/18/15 1350 36 82/37.2
017-033-21 BLACK HAWK 1350-100/50-48 100 50 60/75/90 22/18/15 1350 48 82/37.2
017-035-20 BLACK HAWK 900-200/50-36 200 50 60/75/90 15/12/10 900 36 72/32.7
017-035-21 BLACK HAWK 900-200/50-48 200 50 60/75/90 15/12/10 900 48 72/32.7
017-036-20 BLACK HAWK 1350-200/50-36 200 50 60/75/90 22/18/15 1350 36 82/37.2
017-036-21 BLACK HAWK 1350-200/50-48 200 50 60/75/90 22/18/15 1350 48 82/37.2
017-039-20 BLACK HAWK 2000-240/60-48 240 60 60/75/90 22.25 2000 48 82/37.2

Part # Model Model Description


744-361-20 BLACK HAWK LEGACY MONITOR LEGACY STATUS MONITOR INTERFACE FOR BLACK HAWK
744-362-20 BLACK HAWK HMS MONITOR 3 BATTERY HMS STATUS MONITOR INTERFACE FOR BLACK HAWK 3 BATTERY
744-362-21 BLACK HAWK HMS MONITOR 4 BATTERY HMS STATUS MONITOR INTERFACE FOR BLACK HAWK 4 BATTERY
744-362-22 BLACK HAWK HMS MONITOR 6 BATTERY HMS STATUS MONITOR INTERFACE FOR BLACK HAWK 6 BATTERY
744-362-23 BLACK HAWK HMS MONITOR 8 BATTERY HMS STATUS MONITOR INTERFACE FOR BLACK HAWK 8 BATTERY

744-363-20 BLACK HAWK EMBEDDED MONITOR DOCSIS EMBEDDED STATUS MONITOR FOR BLACK HAWK

Safely transport your Inverter with


the Multilink Inverter Tote

Tote will carry the Multilink


Black Hawk Inverter
or the XM2 Inverter

Part # Description UOM

PENDING AGENCY APPROVAL


10-2420 Inverter Tote for Black Hawk Each

Multilink Broadband Network Powering Products For Outside Plant 13

MULTILINK POWER SOURCE CATALOG 913 13 12/5/2007 12:35:24 AM


Black Hawk Specifications
900 1350 2000
Input Voltage 120VAC 120VAC 240VAC
Input Current 9A 8A 8A
Input Frequency 60 Hz 60 Hz 60 Hz
Line Reject 95V 95V 190V
Line Accept 105V 105V 210V
Output Voltage 60/75/90VAC + 5% / -2% 60/75/90VAC + 5% / -2% 60/75/90VAC + 5% / -2%
Output Current 15/12/10A 15/15A/15A 22A/22A/22A
Output Power 900VA 1350VA 2000VA
Power Factor 0.9 typical 0.9 typical 0.9 typical
Efficiency Line mode: 90% typical (at full load) Line mode: 90% typical (at full load) Line mode: 90% typical (at full load)
Battery Mode: 85% typical (at full load) Battery Mode: 85% typical (at full load) Battery Mode: 85% typical (at full load)
Battery Voltage 36VDC nominal 36VDC nominal 48VDC nominal
Low Battery Cutoff 31.5V nom. (1.75V/cell) 31.5V nom. (1.75V/cell) 42.0 nom. (1.75V/cell)
Battery Acceptance No higher than 37V No higher than 37V No higher than 49V
Battery Charger Bulk, balance and float Bulk, balance and float Bulk, balance and float
Recharge Current 10A max. 10A max. 10A max.
Battery Float Voltage 41.0VDC (2.28V/cell) 41.0VDC (2.28V/cell) 54.7VDC (2.28V/cell)
Recharge Time Not Specified; B45 dependent on depth of discharge, etc.
Charger Temp. Compensation -0.09V/degC; -0.05V/degF with default to internal sensor upon probe failure
Transfer Time 4mS typical, measured at 80% load
Size 15”W x 8.6”H x 12.5”D (381mm x 222mm x 330mm)

The replaceable inverter module


Part # Description UOM
744-353-20 Inverter Module 36V Black Hawk Each
744-353-21 Inverter Module 48V Black Hawk Each

Optional BluetoothTM wireless local access to power supply performance and status up to 100’ away.
Bluetooth is a registered trademark of Bluetooth SIG, Inc., USA

14 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG 914 14 12/5/2007 12:35:25 AM


. BLACK HAWK INTERFACES.

Cheetah and Electroline

Black Hawk HMS Monitor


Interfaces the Black Hawk power supply to
embedded or external transponders complying
with the SCTE-HMS022 protocol using a single
wire harness. Individual battery voltage
measurements for one or two strings of batteries
can also be monitored with the use of an
additional wire harness.

Black Hawk Legacy Monitor


Interfaces the Black Hawk power supply to
legacy analog transponders. The Black Hawk
Legacy Monitor is field configurable for most
analog transponders.

Black Hawk Embedded Cheetah DOCSIS


Embedded DOCSIS status monitoring interface
for the Black Hawk power supply. Individual
battery voltage measurements for one or two
strings of batteries can also be monitored with
the use of an additional wire harness.

Multilink Broadband Network Powering Products For Outside Plant 15

MULTILINK POWER SOURCE CATALOG.iSec1:15 Sec1:15 6/6/2007 12:44:34 PM


How to tell the difference between True UPS and Cable UPS/Standby Power

60Hz
+/- 3Hz

Thermistor &
MOV Protection
120V
+/- 15%

1
10 ms
50 V

No Isolation
2 Little Protection
20 ms
20.0 V

Output Is
Sometimes
Interrupted

Status
Monitoring Charger Output
Interface Limited - 6A At
Full Load

Option At
Added Cost

Risk Outage To
Complex Test Battery
Controller & Inverter

16 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:16 Sec1:16 6/6/2007 12:44:36 PM


. COMMON FERRO.

400A Inrush
Isolation Current May
Line Trip Breaker
Relay
Sense
Must Disconnect
For Inverter

Ferro
Transfer On
Transients
And Noise

Battery Output
Charger

Must Connect
For Inverter

Fans Required
Inverter

Cold Start
Inverter

Multilink Broadband Network Powering Products For Outside Plant 17

MULTILINK POWER SOURCE CATALOG.iSec1:17 Sec1:17 6/6/2007 12:44:41 PM


The Features
Compact Design, Saves Space
Designed For 60 Homes And Less

Little Hawk 500


Output VA 500
Output VA 60 / 75 / 90
Output A 8.3 / 6.6 / 5.5
Transfer Time 4mS
Input V (nom) 120 or 220
Battery V 36 (3 battery) 48 (4 battery)
Status Monitor Optional Legacy / HMS Serial
StatTrak / Cheetah / Tollgrade / Electroline

Specifications
Weight 45 lbs
Environmental -40C to 60C 0-95% RH non-condensing
Protection 85A battery circuit breaker
Temperature Sensor 2 pin mini mate-n-lock

Battery String Voltage


Low Battery Cut Off 36V System 31.5V (1.75 VPC)
Battery Acceptance 36V System 37 VDC TYP
Battery Acceptance 48V System 49 VDC TYP

Low Line Reject


Little Hawk - 120 95 VAC
Little Hawk - 220 190 VAC

Status Monitoring Compatible With
StatTrak, Tollgrade/Cheetah, AM Comm, Phoenix Power
Agent, SA ROSA, and Embedded Cheetah DOCSIS

PENDING AGENCY APPROVAL

18 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG 918 18 12/5/2007 12:35:31 AM


. LITTLE HAWK POWER SUPPLY .

We Can Accommodate Your Status Monitoring Requirements

Status Monitoring Compatible With


StatTrak, Tollgrade/Cheetah, AM Comm,
Phoenix Power Agent, SA ROSA,
and Embedded Cheetah DOCSIS

Optional BluetoothTM wireless local access to power supply performance and status up to 100’ away.
Bluetooth is a registered trademark of Bluetooth SIG, Inc., USA

Multilink Broadband Network Powering Products For Outside Plant 19

MULTILINK POWER SOURCE CATALOG 919 19 12/5/2007 12:35:34 AM


The Power Supply For Forward Thinking Engineers
PATENTED

Externally Located Input and Output Circuit Breakers

The Only True UPS/Mission Critical Power Supply

True UPS Mission Critical HMS RS485


No transfer, No interruption LCD Display
Temperature-compensated four-stage charger Universal input
90V/75V/60V operation Battery temperature sensor

The MP Plus power supply traces its roots to services started in 1998 with its forerunner, the MP True UPS. At that time, power
supplies based on the true UPS concept constituted the largest trouble-free installations of any CATV / Broadband network
power supply in the world. The key to part of this success is the universal input that allows this particular power supply to operate
from a wide range of voltages. Consequently, line voltage spikes, sags and minor surges that occur daily on the AC utility lines
are absorbed in the input circuits of the MP Plus power supply. If a brownout, blackout or momentary loss of AC power occurs,
the transfer to the battery backup inverter is seamless with absolutely no power anomalies being reflected to the load. Circuit
topology within the MP Plus series provides a true UPS product suitable for today’s mission-critical applications, offering the best
and most reliable back-up source for services such as VoIP and others. Standby power supplies simply cannot provide the quality
of power and the ongoing reliability offered in the MP Plus True UPS power supply.

US Patent # 5,994,793 & US 6,268,665 B1

20 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:20 Sec1:20 6/6/2007 12:44:49 PM


. MP Plus Power Supplies .
VoIP Ready
Specifications MP Plus 900, 1350-120, 1350-240
Size MP Plus 900 16”W x 8.625”H x 12”D
MP Plus 1350
Weight MP Plus 900 & 1350 65/72 lbs
Environmental -40 to 60C 95% RH non condensing
Protection I-Track electronic current limit and
output breakers battery circuit breaker
Cabinet Lights 4 pin mini mate-n-lock
Temperature Sensor 2 pin mini mate-n-lock
Test Jacks Output voltage (TRMS)
Output current (TRMS)
Battery String Voltage
Low Battery cut off 36V System, 31.5V(1.75 VPC)
48V System, 42(1.75 VPC)

Battery Acceptance 36V System, 37VDC TYP


48V System, 49 VDC TYP
Low Line Reject MP Plus 900 80 VAC
MP Plus 1350 - 120 95 VAC
MP Plus 1350 - 240 170 VAC
Status Monitor HMS RS485

New Features:
- HMS RS485 serial status monitoring
- Compatible with StatTrak/Tollgrade/Cheetah/Electroline
- Electronically controlled output current protection, no Smart Breaker required
- Smaller physical package, the MP Plus is 1/2” shallower than the previous supply (12” X 16.25” X 8.625”)
- Redesigned top cover to reduce water migration
- Externally located input and output circuit breakers
- Output voltage tap is accessible without removing front panel

The New Serial Status Monitoring Port Monitors:


- Output #1 and output #2 current - Major alarm
- Output #1 voltage - Minor alarm
- Input voltage - Inverter status
- Input current - Last test status
- Battery string voltage - Tamper switch
- Test start/stop

All of this is monitored with no external hardware, such as line sense transformers or output voltage wire harnesses. This
reduces the complexity of installation and reduces clutter in the enclosure. The Power Supply to Transponder Interface Bus
(PSTIB) is designed to allow up to 32 devices. Locations with multiple power supplies can use a single transponder to monitor
all of the power supplies.

To monitor individual battery voltages, Mulitlink is offering the MPHMS Battery Monitor. This device is capable of monitoring
up to 16 batteries and communicates to the HMS transponder over the same PSTIB as the power supply.

Optional BluetoothTM wireless local access to power supply performance and status up to 100’ away.
Bluetooth is a registered trademark of Bluetooth SIG, Inc., USA

Multilink Broadband Network Powering Products For Outside Plant 21

MULTILINK POWER SOURCE CATALOG.iSec1:21 Sec1:21 6/6/2007 12:44:51 PM


MULTIPOWER MP Plus Series True UPS/Mission Critical
VOIP Ready For CATV Broadband Networks
PATENTED

Dual Outputs
Electronically Can Run 90 And 60 Volt Easy Access
Controlled Output Plant On Each Output Output Selector
Current Protection No Dip Switches Universal Input Offers
“Self Resets” To Mess With A Wide Range Of Input
Voltage And Frequency

Dual Heat
Sinks

LCD
Display

Standard
Battery
Connector

Circuit Breakers
No Fuses To
Replace HMS RS485
Serial Status
Monitoring

Size (12” x 16.25” x 8.625”)


Fits most power supply cabinets

US Patent # 5,994,793, US Patent # US 6,268,665 B1, US Patent # 6,932,443

22 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:22 Sec1:22 6/6/2007 12:44:52 PM


. MP Plus Power Supplies .
Nominal Specifications For MP 900 & 1350 True UPS Power Supplies
Nominal Input Input Output Output Max Output Battery Approximate
Part # Model Description Voltage VAC Frequency Hz Voltage VAC Current A Power VA Voltage VDC Wt. lbs/kg
017-022-20 MP PLUS 900-120-36 W/HMS 120 47-63 60/75/90 15/12/10 900 36 60/27.2
017-022-21 MP PLUS 900-240-36 W/HMS 240 47-63 60/75/90 15/12/10 900 36 60/27.2
017-022-22 MP PLUS 900-120-48 W/HMS 120 47-63 60/75/90 15/12/10 900 48 60/27.2
017-022-23 MP PLUS 900-240-48 W/HMS 240 47-63 60/75/90 15/12/10 900 48 60/27.2
017-022-24 MP PLUS 900-120-36 WO/HMS 120 47-63 60/75/90 15/12/10 900 36 60/27.2
017-022-25 MP PLUS 900-240-36 WO/HMS 240 47-63 60/75/90 15/12/10 900 36 60/27.2
017-022-26 MP PLUS 900-120-48 WO/HMS 120 47-63 60/75/90 15/12/10 900 48 60/27.2
017-022-27 MP PLUS 900-240-48 WO/HMS 240 47-63 60/75/90 15/12/10 900 48 60/27.2
017-023-20 MP PLUS 1350-120-36 W/HMS 120 47-63 60/75/90 22/18/15 1350 36 72/32.7
017-023-21 MP PLUS 1350-240-36 W/HMS 240 47-63 60/75/90 22/18/15 1350 36 72/32.7
017-023-22 MP PLUS 1350-120-48 W/HMS 120 47-63 60/75/90 22/18/15 1350 48 72/32.7
017-023-23 MP PLUS 1350-240-48 W/HMS 240 47-63 60/75/90 22/18/15 1350 48 72/32.7
017-023-24 MP PLUS 1350-120-36 W0/HMS 120 47-63 60/75/90 22/18/15 1350 36 72/32.7
017-023-25 MP PLUS 1350-240-36 W0/HMS 240 47-63 60/75/90 22/18/15 1350 36 72/32.7
017-023-26 MP PLUS 1350-120-48 W0/HMS 120 47-63 60/75/90 22/18/15 1350 48 72/32.7
017-023-27 MP PLUS 1350-240-48 W0/HMS 240 47-63 60/75/90 22/18/15 1350 48 72/32.7
017-038-20 MP PLUS LCD 1350-120-36 120 47-63 60/75/90 22/18/15 1350 36 72/32.7

True UPS/Mission Critical Power Supply

PENDING AGENCY APPROVAL

Multilink Broadband Network Powering Products For Outside Plant 23

MULTILINK POWER SOURCE CATALOG.iSec1:23 Sec1:23 6/6/2007 12:44:53 PM


How to tell the difference between True UPS and Cable UPS/Standby Power

Rides Through
Transients & Noise
65z
to 65Hz

Line High Volume


Conditioning Boast
120V-35%
to +120%
High
Isolation
2
10 ms
20.0 V

True
UPS 3
10 ms
20.0 V

Full 10A Charger


At All Loads
Status
Monitoring
Interface

Standard
Feature

Simplified
Controller

24 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:24 Sec1:24 6/6/2007 12:44:55 PM


. CONFLUENT POWER.

AC Converted DC Converted
To DC To AC

High Voltage
Rectifier
Inverter

Soft Start-No
Inrush Current

Ferro

Simultaneous
Inverter Operation
No Switching

Output

Battery
Charger

No Risk Battery
& Inverter Test

Low Voltage Low Voltage No Cooling


Boost Inverter Fans Required

Multilink Broadband Network Powering Products For Outside Plant 25

MULTILINK POWER SOURCE CATALOG.iSec1:25 Sec1:25 6/6/2007 12:45:00 PM


NS Series Non-Standby Power Supply for Broadband Networks

Specifications NS Non-Standby Series


Regulation 5% Traditional ferroresonant non-standby
Input Voltage Range ±15%
powering
Frequency ±3Hz
Compact package, self-contained
Tap Voltages* 50 = 48V
Replaceable internal components
60 = 63V Pole mount
75 = 75V
90V = 87V Low Cost Non-Standby
Foldback Current 125%<x<150%
High Efficiency
Power Factor >.9
50V, 60V and 60/75/90V Models with 3, 6,
Audible Noise < 40dBa @ 10’
10 or 15A Output
Powder Coated Aluminum Enclosure
Efficiency > 90% full load
> 80% half load

Operating Temperature -40°C to +65°C


Size 15 5/8”H x 11 1/8”W x 8 1/4”D
Options
(397mm x 283mm x 210mm) NS-OI - NS Series Output Indicator,
Exclusive of pole-mount bracket
Long Life Green LED Indicates
AC Output Voltage
OD-1 - Output Delay Relay
SA-1 - Input Surge Arrestor

* Not all voltages available on all models

26 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:26 Sec1:26 6/6/2007 12:45:05 PM


. NS NON-STANDBY / SERVICE SUPPLY.
MPS-TM Service Supply

The MPS-TM assembly is a portable, non-standby power supply used as a service supply that provides conditioned AC
power to the cable plant load when the main power supply is taken off-line for service. Used in conjunction with an AC
output cable and the source selector switch in the enclosure’s power inserter (PIM-G), service supply with minimum
interruption. The MPS-TM assembly is equipped with tap settings that allow convenient selection of 60, 75, or 90 VAC
output, suitable for a wide range of applications.

The MPS-TM Service Supply Is Available In 900 And 1350 Watt Output Ratings
MPS 900 MPS 1350(120V) MPS 1350(240V)
Input Voltage 120AC nominal 120AC 240AC
Input Current 12 MAX 17 MAX 9 MAX
Input Frequency 60 Hz 60 Hz 60 Hz
Output Voltage 60/75/90VAC 60/75/90VAC 60/75/90VAC
Output Current 15/12/10A 22.5/18/15A 22.5/18/15A
Output Power 900VA 1350VA 1350VA
Output Current Limit 150% Max of Full Load Rating 150% Max of Full Load Rating 150% Max of Full Load Rating
Efficiency Line mode: 90% typical (at full load) Line mode: 90% typical (at full load) Line mode: 90% typical (at full load)
Finish Diamond Black Diamond Black Diamond Black
Operating Temperature Range -40°F to 122°F -40°F to 122°F -40°F to 122°F
-40°C to 50°C -40°C to 50°C -40°C to 50°C
Dimensions 8”H x 6 1/2”W x 11 1/2”D 8”H x 6 1/2”W x 11 1/2”D 8”H x 6 1/2”W x 11 1/2”D
(203mm x 165mm x 292mm)” (203mm x 165mm x 292mm) (203mm x 165mm x 292mm)
Weight 45 lbs/20 kg 60 lbs/27 kg 60 lbs/27 kg
Input Cord Grip 5-15P 5-20P 6-15P

Multilink Broadband Network Powering Products For Outside Plant 27

MULTILINK POWER SOURCE CATALOG.iSec1:27 Sec1:27 6/6/2007 12:45:07 PM


Battery Load Tester

Rugged, precise 3” jeweled D’Arsonval meter with zero adjust


Chrome-plated steel housing with rubber grip handle and
side test clamp holders
Heavy-duty, UL-listed, momentary test switch
Manganese wire resistance element shunt grid
Extra heavy 10 AWG 12” leads with strain relief and color-
coded, insulated, copper plated steel battery post clamps
1 year warranty
With full 100-amp load-testing capacity, this reliable and highly
accurate tester works on both 6- and 12-volt batteries. The unit
performs both a voltage test and 15-second battery-load testing.
Results are displayed on a color-coded 0-16 volt scale.

Battery Balance Manager


Reduce Battery
Replacement Cost!

No more need to maintain matched battery sets for field replacement!


A New Way To Manage Batteries!
The First Battery Balance in CATV
Combine new replacements with older batteries in existing strings (*1)
Active battery charge equalization at float voltages
Automatically and correctly tracks charger voltage and temperature compensation
Battery string charges at full charger current, up to maximum of CATV supply capability
Evenly distributes charge across all batteries in the string preventing potential undercharge
and overcharge damage
Can be used with any manufacturer’s CATV power supply
May be used to balance the batteries in any three or four battery power supply (*2)
Models are available for use with 36V (three Battery) and 48V (four battery) systems

*1. Replacement battery must be same type , chemistry, size, and AH rating.
*2. On 36V systems, one balancer is required for every string of three batteries. On 48V systems one balancer is required for every string of four batteries.

28 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:28 Sec1:28 6/6/2007 12:45:08 PM


. BATTERY BALANCE MANAGER.
Battery Balance Manager
Without Balancer
13.95v #1
CATV
40.5v 13.05v #2 Power
Total Supply
13.5v #3
Float Charging
(Assume 250 c Temperature
Battery #1 Overcharged
Battery #2 Undercharged
Battery #3 Just Right

With Balancer

13.5v #1 Low
CATV Battery
40.5v Power Cutoff
BBN 13.5v #2 Supply Monitor
Total 36
13.5v #3 Float Charging
(Assume 250 c Temperature
All Batteries Have Correct Voltage And Are Just Right

Technical Specifications
Balance Rate
48 hours typical to 66 mV after complete discharge/recharge cycle, measured using new
100AH batteries
Maximum String Charge
Current limited by capability of CATV power supply charger
Environmental
-40ºC to +60ºC, 0-99%RH non-condensing
Balance Accuracy
65mV per battery or better when battery capacity mismatch does not exceed 20%
Overload Protection
Electronic self-resetting current protection. Accidental reverse polarity protection

Part # Description Voltage Dimensions UOM


018-008-20 BBM Plus 36V (kit for 3 batteries, includes wiring harness and instructions) 36 6”L x 3.5”W x 2.25D” Each
018-009-20 BBM Plus 48V (kit for 4 batteries, includes wiring harness and instructions) 48 6”L x 3.5”W x 2.25D” Each
740-029-20 BBM Plus unit (auto configures for 3 or 4 batteries) 36/48 6”L x 3.5”W x 2.25D” Each
870-069-21 Wiring Harness for a BBM 3 Batteries 36 n/a Each
870-070-21 Wiring Harness for a BBM 4 Batteries 48 n/a Each
018-008-A0 Instruction Manual for BBM Plus n/a n/a Each

Specifications subject to change without notice

Multilink Broadband Network Powering Products For Outside Plant 29

MULTILINK POWER SOURCE CATALOG.iSec1:29 Sec1:29 6/6/2007 12:45:12 PM


Power Tron™
by Multilink

Gel & AGM Batteries


Full and optional programs for new batteries and replacement batteries in Gel and
AGM models
The Gel and AGM batteries are manufactured to meet the broadband applications
without compromising quality
Premium Gel models last 6% longer than regular Gel batteries
Full replacement and prorated programs available
Full recycling locations and a $5.00 credit back program on recycled batteries available
National location center for services

Battery Replacement Recycling Program


Multilink Understands
Batteries play an indispensible role in in the stability and reliability of VoIP-enabled networks.
Multilink’s Power Tron™
Our batteries will meet the demand by having a nation wide distribution program that provides
local battery inventory and EPA certified recycle programs. In addition, we have now introduced
in 2007, as an option, the $5.00 credit program. Upon pick up of your batteries, we will give
you $5.00 credit on each battery we recycle.
Training Benefits
At no cost to you, we train and give 24/7 Service training to all your technicians or sub
contractors with written instructions and photos of how to keep the PM on your powering
network.
At No Cost To Your System
We will travel to the location and train your staff. If you wish to have the PM subcontracted out
to someone other than your subcontractor, we have Multilink approved contractors trained and
certified by our staff.
Flexible
We can customize a program to fit your needs. Email us at engsupport@multilinkone.com or
call us at 440.366.6966.

30 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:30 Sec1:30 6/6/2007 12:45:13 PM


. BATTERIES.
Power Tron™ Features
Gel AGM
Standard Warranty 5 Year Full Replacement 3 Year Full Replacement 1 Year Full Replacement
Services Life Extended
Runtime (minutes) 180, 165 or 85 180, 165 or 85 170
Sealed VRLA Valve regulated lead acid Valve regulated lead acid Valve regulated lead acid
Heat Resistant High High Mid range moderate
Cool Resistant Moderate Moderate High
Hydrogen Emission Low Low Low
Terminals (optional post available) 3/8 Threaded Stud 3/8 Threaded Stud 3/8 Threaded Stud

Specifications
PV31 PV27 AGM
Model 032-027-10 032-028-10 SK1200-SW
Battery Type SN Alloy SN Alloy
Cells per Unit 6 6 6
Voltage per Unit 12 12 12.8
Conductance Value 1000 1000 1000
Max Discharge current(A) 900 900 850
Short Circuit Current(A) 2600 2600 3400
10 Second Volts @ 100 Amp 11.2 11.2 11.4
Ohms Impedance 60Hz 0.0055 0.0055 0.006
Capacity at 20 hours (to 1.75VPC) 107 Ah 92 Ah 89 Ah
BCI Group Size 31 31 31

Weight (lbs) 68.4 65.5 63


Height w/ terminals 8.39” (213mm) 8.19” (208mm) 9.05” (229.8mm)
Width (in/mm)3 13.07” (332mm) 12.01” (305mm) 11.95” (303.5mm)
Depth(in/mm)3 6.85” (174mm) 6.61” (168mm) 6.83” (173.4mm)
Operating Temperature Range -40° to 72° -40° to 72° -40° to 72°
Discharge °C -40° to 72° -40° to 72° -40° to 72°
Float Charging Voltage VDC 13.5 - 13.8 13.5 - 13.8 13.5 - 13.8

Other batteries available upon request


All specifications and part numbers are subject to change without notice.

Gel AGM

Multilink Broadband Network Powering Products For Outside Plant 31

MULTILINK POWER SOURCE CATALOG.iSec1:31 Sec1:31 6/6/2007 12:45:14 PM


MultiCell Front Terminal Batteries

Specifications Specifications
Front Terminal AGM Battery Front Terminal Gel Battery
Nominal Voltage 12V Nominal Voltage 12V
Rated Capacity 10 hour rate to 1.80Vpc) 110AH Rated Capacity (10 hour rate) 100AH
Rated Capacity 108AH Total Height (with 285mm (11.22 inches)
(8 hour rate to 1.75Vpc) Dimension terminals)
Total Height 285mm (11.22 inches) Height 285mm (11.22 inches)
Dimension (with terminals)
Length 394mm (15.51 inches)
Height 285mm (11.22 inches)
Width 110mm (4.33 inches)
Length 394mm (15.51 inches)
Weight Approx. 37.0kg (81.57 lbs)
Width 110mm (4.33 inches)
Weight Approx. 37.0kg (81.57 lbs)

Characteristics
Characteristics Capacity 77F (25C) 20 hour rate (5.38A) 107.5AH
Capacity 77F (25C) 10 hour rate (11A) 110AH 10 hour rate (10A) 100AH
8 hour rate (13.5A) 108AH 5 hour rate (18.3A) 91.4AH
5 hour rate (20.1A) 105.5AH 1 hour rate (64.5A) 64.5AH
1 hour rate (71A) 71AH 15 min rate (188A) 47AH
Internal Resistance Full charged 77F (25C) 3.3mΩ Internal Resistance Full charged 77F (25C) 3.3mΩ
Capacity affected 104F (40C) 102% Capacity affected 104F (40C) 102%
by Temperature by Temperature
(20 hour rate) (20 hour rate)
77F (25C) 100% 77F (25C) 100%
32F (0C) 85% 32F (0C) 85%
5F (-15C) 65% 5F (-15C) 65%
Self-Discharge Capacity after 3 month 91% Self-Discharge Capacity after 3 month 91%
77F (25C) storage 77F (25C) storage
Capacity after 6 month 82% Capacity after 6 month 82%
storage storage
Capacity after 12 month 64% Capacity after 12 month 64%
storage storage
Max. Discharge 1500A (5S) Max. Discharge 1500A (5S)
Current 77F (25C) Current 77F (25C)
Terminal Standard F17 Terminal Standard F17
Optional Optional
Charging Cycle Initial Charging Current Charging Cycle Initial Charging Current
(Constant Voltage) 22A or Small 14.5V (Constant Voltage) 20A or Small 14.5V
- 14.9V/ 77F (25C) - 14.9V/ 77F (25C)
Float 13.6V - 13.8V / 77F (25C) Float 13.6V - 13.8V / 77F (25C)

32 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:32 Sec1:32 6/6/2007 12:45:15 PM


. POLE MOUNT POWER SUPPLY ENCLOSURE.
Pole Mount Power Supply Enclosures Flat Roof

030-049-10

Designed to house broadband power supplies and batteries in any pole-mounted application.
Standard features include durable construction with exterior finished in light equipment gray powder
paint. Custom colors are available upon request.
Totally enclosed design offers highest security from tampering or unauthorized entry, yet provides
flexibility in locating utility and cable entrance locations.
Battery slide trays lock in both closed and extended positions.
Front door is hinged for easy-open access, but is also removable for ease of installation and service of
enclosed equipment. Door is locked in the closed position with high-security latches.
Flat roof with side flanges affords a rainproof design, yet flips up to allow unhindered access to
equipment and battery spaces.
Optional life saver vented roof available.

Multilink Broadband Network Powering Products For Outside Plant 33

MULTILINK POWER SOURCE CATALOG.iSec1:33 Sec1:33 6/6/2007 12:45:18 PM


Pole Mount Enclosures-Economy Models Flat Roof
Standard Pole Mount Enclosures / Flat Roof
Part # 030-049-10 030-064-10 030-068-10 030-066-10 030-071-10
Model PM 3-E PM 3/4-EN PM 4-EW PM 6/8-EN PM 8-EW
Main Application Power Supply & Power Supply & Power Supply & Power Supply & Power Supply &
Battery Enclosure Battery Enclosure Battery Enclosure Battery Enclosure Battery Enclosure
Power Supply Shelf X X X X X
Battery Shelf X X X X X
Hinged Door X X X X X
Ground Lug X X X X X
Group 24 3 3 or 4 3 or 4 6 or 8 6 or 8
Group 27 or 31 3 3 3 or 4 6 6 or 8
AC Service External X X X X X

Pole Mount Enclosures-Economy Models (Options Available)


Service Entrance 120V, 20A Standard n/a n/a n/a n/a
120V, 20A Hi Inrush 035-001-11 “SQD-1HM” 035-001-11 “SQD-1HM” 035-001-11 “SQD-1HM” 035-001-11 “SQD-1HM”
240V, 20A 1 Outlet 035-002-10 “SQD-2” 035-002-10 “SQD-2” 035-002-10 “SQD-2” 035-002-10 “SQD-2”
240V, 20A Dual Outlet 035-009-10 “SQD-3” 035-009-10 “SQD-3” 035-009-10 “SQD-3” 035-009-10 “SQD-3”
120V, 20A Duplex 035-007-10 “DOK-1” 035-007-10 “DOK-1” 035-007-10 “DOK-1” 035-007-10 “DOK-1”
240V, 15A Duplex 035-008-10 “DOK-2” 035-008-10 “DOK-2” 035-008-10 “DOK-2” 035-008-10 “DOK-2”
Indicators High Brightness 035-003-10 “ELK-1” 035-003-10 “ELK-1” 035-003-10 “ELK-1” 035-003-10 “ELK-1”
Economy 035-015-10 “ELK-E” 035-015-10 “ELK-E” 035-015-10 “ELK-E” 035-015-10 “ELK-E”
Single Light 035-036-20 “SIL-E” 035-036-20 “SIL-E” 035-036-20 “SIL-E” 035-036-20 “SIL-E”
Output Interface Economy 740-015-20 “PIM-E” 740-015-20 “PIM-E” 740-015-20 “PIM-E” 740-015-20 “PIM-E”
Standard 740-009-20 “PIM-G” 740-009-20 “PIM-G” 740-009-20 “PIM-G” 740-009-20 “PIM-G”
Filtered 740-011-20 “PIM-F” 740-011-20 “PIM-F” 740-011-20 “PIM-F” 740-011-20 “PIM-F”
Battery Wiring Kits 3-battery 30 Amp 874-001-20 “BWK-3” 874-001-20 “BWK-3” n/a n/a
3-battery 50 Amp 874-001-21 “BWK-3HD” 874-001-21 “BWK-3HD” n/a n/a
4-battery 30 Amp n/a n/a n/a n/a
6-battery 30 Amp n/a n/a 874-003-20 “BWK-6” 874-003-20 “BWK-6”
6-battery 50 Amp n/a n/a 874-003-21 “BWK-6HD” 874-003-21 “BWK-6HD”
8-battery 30 Amp n/a n/a 874-004-20 “BWK-8” 874-004-20 “BWK-8”

030-068-10

030-049-10

34 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:34 Sec1:34 6/6/2007 12:45:20 PM


. GROUND MOUNT POWER SUPPLY ENCLOSURE.
Ground Mount Power Supply Enclosures Flat Roof

Designed to house broadband power supplies and batteries in any ground mounted application.
Standard features include durable construction with exterior finished in light equipment gray powder
paint. Custom colors are available upon request.
Totally enclosed design offers highest security from unauthorized tampering or entry, yet provides
flexibility in locating utility and cable entrance locations.
Battery slide trays lock in both closed and extended positions.
Front door is hinged for easy-open access, but is also removable for ease of installation and service of
enclosed equipment. Door is locked in the closed position with high-security latches.
Flat roof with side flanges affords a rainproof design, yet flips up to allow unhindered access to
equipment and battery spaces.
Optional life saver vented roof available.

Multilink Broadband Network Powering Products For Outside Plant 35

MULTILINK POWER SOURCE CATALOG.iSec1:35 Sec1:35 6/6/2007 12:45:22 PM


Standard Ground Mount Enclosures / Flat Roof
Part # 030-050-10 030-065-10 030-069-10 030-067-10 030-070-10
Model GM 3-E GM 3/4-EN GM 4-EW GM 6/8-EN GM 8-EW
Main Application Power Supply & Battery Power Supply & Battery Power Supply & Battery Power Supply & Battery Power Supply & Battery
Enclosure Enclosure Enclosure Enclosure Enclosure
Power Supply Shelf X X X X X
Battery Shelf X X X X X
Hinged Door X X X X X
Ground Lug X X X X X
Group 24 3 3 or 4 3 or 4 6 or 8 6 or 8
Ground 27 or 31 3 3 3 or 4 6 6 or 8
AC Service External X X X X X

Standard Ground Mount Enclosures (Options Available)


Part # 030-050-10 030-065-10 030-069-10 030-067-10 030-070-10
Model GM 3-E GM 3/4-EN GM 4-EW GM 6/8-EN GM 8-EW
Main Application Power Supply & Power Supply & Power Supply & Power Supply & Power Supply &
Battery Enclosure Battery Enclosure Battery Enclosure Battery Enclosure Battery Enclosure
Service Entrance 120V, 20A Standard n/a n/a n/a n/a n/a
120V, 20A Hi Inrush 035-001-11 035-001-11 035-001-11 035-001-11 035-001-11
“SQD-1HM” “SQD-1HM” “SQD-1HM” “SQD-1HM” “SQD-1HM”
240V, 20A 1 Outlet 035-002-10 “SQD-2” 035-002-10 “SQD-2” 035-002-10 “SQD-2” 035-002-10 “SQD-2” 035-002-10 “SQD-2”
240V, 20A Dual Outlet 035-009-10 “SQD-3” 035-009-10 “SQD-3” 035-009-10 “SQD-3” 035-009-10 “SQD-3” 035-009-10 “SQD-3”
120V, 20A Duplex 035-007-10 “DOK-1” 035-007-10 “DOK-1” 035-007-10 “DOK-1” 035-007-10 “DOK-1” 035-007-10 “DOK-1”
240V, 15A Duplex 035-008-10 “DOK-2” 035-008-10 “DOK-2” 035-008-10 “DOK-2” 035-008-10 “DOK-2” 035-008-10 “DOK-2”
Indicators High Brightness 035-003-10 “ELK-1” 035-003-10 “ELK-1” 035-003-10 “ELK-1” 035-003-10 “ELK-1” 035-003-10 “ELK-1”
Economy 035-015-10 “ELK-E” 035-015-10 “ELK-E” 035-015-10 “ELK-E” 035-015-10 “ELK-E” 035-015-10 “ELK-E”
Single Light 035-036-20 “SIL-E” 035-036-20 “SIL-E” 035-036-20 “SIL-E” 035-036-20 “SIL-E” 035-036-20 “SIL-E”
Output Interfaces Economy 740-015-20 “PIM-E” 740-015-20 “PIM-E” 740-015-20 “PIM-E” 740-015-20 “PIM-E” 740-015-20 “PIM-E”
Standard 740-009-20 “PIM-G” 740-009-20 “PIM-G” 740-009-20 “PIM-G” 740-009-20 “PIM-G” 740-009-20 “PIM-G”
Filtered 740-011-20 “PIM-F” 740-011-20 “PIM-F” 740-011-20 “PIM-F” 740-011-20 “PIM-F” 740-011-20 “PIM-F”
Battery Wiring Kits 3-battery 30 Amp 874-001-20 “BWK-3” 874-001-20 “BWK-3” 874-001-20 “BWK-3” n/a n/a
3-battery 50 Amp 874-001-21 874-001-21 874-001-21 n/a n/a
“BWK-3HD” “BWK-3HD” “BWK-3HD”
4-battery 30 Amp n/a n/a n/a n/a n/a
6-battery 30 Amp n/a n/a n/a 874-003-20 “BWK-6” 874-003-20 “BWK-6”
6-battery 50 Amp n/a n/a n/a 874-003-21 874-003-21
“BWK-6HD” “BWK-6HD”
8-battery 30 Amp n/a n/a n/a 874-004-20 “BWK-8” 874-004-20 “BWK-8”

36 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:36 Sec1:36 6/6/2007 12:45:25 PM


. LIFE SAVER.
Ventilation System, Key To Battery And Electronics Extended Life
PATENTED

Given proper charging and installation, battery service


life is dependent primarily on average operating LIFE SAVER
temperature. Lead-acid battery chemistry is highly
temperature dependent. For each 15°F increase
over 77°F in average operating temperature, a
corresponding service life reduction of 50% is
predicted. This means, in simpler terms, that a
5-year battery in a cool climate will be a 2.5-year
battery in a hot climate. Operating temperatures,
however, due to sun-loading, can be much higher
than local ambient temperatures if the enclosure is
not designed to exchange ambient air effectively.

“Sun-loading” in hot climates can raise internal


cabinet temperatures to 130°F and above if internal
air is not continuously replaced by cooler, outside
ambient air. Of course, 130°F temperatures turn a
5-year battery into a 5-month battery!

The key is to allow convective or fan-forced air


movement through the cabinet to replace internally
heated air with cooler ambient air rapidly enough
to reduce inside temperatures to values as close to
ambient as possible. This can only be done by
using adequately large air entry and exit vents.
Multilink’s entry and exit areas exceed 44 square
inches on all cabinets, allowing temperatures to
rise less than a few degrees over.

Even in cooler climates, short hot summers have


a life-draining effect: Mulitlink’s free-flow “Life A patented vented battery
Saver” cabinets still work to maximize battery life. tray allows air to pass
through the batteries
Multilink’s battery trays are sized to permit one-inch
spacing between batteries on all sides, exposing
maximum battery surface area to cooling air flow.
Venting patterns in battery trays support optimum
cooling air flow for both 3- and 4-battery layouts. When
you upgrade from 36V to 48V (higher power, higher
efficiency UPS units) there is no need for expensive
cabinet change-outs.

US Patent 6,932,443.B1

Multilink Broadband Network Powering Products For Outside Plant 37

MULTILINK POWER SOURCE CATALOG.iSec1:37 Sec1:37 6/6/2007 12:45:27 PM


Ground Mount Enclosures Life Saver
PATENTED

Typical ground mount enclosure equipped with optional life saver vented roof

Designed to house broadband power supplies and batteries in any ground-mounted application.
May be used with pre-cast or poured-in-place concrete pads, vaults or any other desired mounting
options.
Open bottom design accommodates all vault-and-pad installations, allowing flexibility of utility and
cable entrance locations.
Standard features include durable construction with exterior finished in light equipment
gray powder paint. Custom colors are available upon request.
Battery slide trays lock in both closed and extended positions.
Front and rear doors are removable for ease of installation and service of enclosed equipment. Doors
are locked in the closed position with high-security latches.

38 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:38 Sec1:38 6/6/2007 12:45:31 PM


. GROUND MOUNT SAVER ENCLOSURE.
Standard Ground Mount Enclosures Life Saver

Standard Ground Mount Enclosures / Life Saver


Part # 030-015-10 030-040-10 030-017-10 030-042-10
Model GM 3/4-N GM 4-W GM 6/8-N GM 8-W
Main Application Power Supply & Battery Power Supply & Battery Power Supply & Battery Power Supply & Battery
Enclosure Enclosure Enclosure Enclosure
Power Supply Shelf X X X X
Battery Shelf X X X X
Hinged Door X X X X
Ground Lug X X X X
Group 24 3 or 4 3 or 4 6 or 8 6 or 8
Group 27 or 31 3 3 or 4 6 6 or 8
AC Service External X X X X

Standard Ground Mount Enclosures (Options Available)


Part # 030-015-10 030-040-10 030-017-10 030-042-10
Model GM 3/4-N GM 4-W GM 6/8-N GM 8-N
Main Application Power Supply & Battery Power Supply & Battery Power Supply & Battery Power Supply & Battery
Enclosure Enclosure Enclosure Enclosure
Life Saver Venting X X X X
Service Entrance 120V, 20A Standard 035-001-20 “SQD-1” 035-001-20“SQD-1” 035-001-20 “SQD-1” 035-001-20 “SQD-1”
120V, 20A Hi Inrush 035-001-11 “SQD-1HM” 035-001-11“SQD-1HM” 035-001-11 “SQD-1HM” 035-001-11 “SQD-1HM”
240V, 20A 1 Outlet 035-002-11 “SQD-2” 035-002-10 “SQD-2” 035-002-10 “SQD-2” 035-002-10 “SQD-2”
240V, 20A Dual Outlet 035-009-10 “SQD-3” 035-009-10 “SQD-3” 035-009-10 “SQD-3” 035-009-10 “SQD-3”
120V, 20A Duplex 035-007-10 “DOK-1” 035-007-10 “DOK-1” 035-007-10 “DOK-1” 035-007-10 “DOK-1”
240V, 15A Duplex 035-008-10 “DOK-2” 035-008-10 “DOK-2” 035-008-10 “DOK-2” 035-008-10 “DOK-2”
Indicators High Brightness 035-003-10 “ELK-1” 035-003-10 “ELK-1” 035-003-10 “ELK-1” 035-003-10 “ELK-1”
Economy 035-015-10 “ELK-E” 035-015-10 “ELK-E” 035-015-10 “ELK-E” 035-015-10 “ELK-E”
Single Light 035-036-20 “SIL-E” 035-036-20 “SIL-E” 035-036-20 “SIL-E” 035-036-20 “SIL-E”
Output Interfaces Economy 740-015-20 “PIM-E” 740-015-20 “PIM-E” 740-015-20 “PIM-E” 740-015-20 “PIM-E”
Standard 740-009-20 “PIM-G” 740-009-20 “PIM-G” 740-009-20 “PIM-G” 740-009-20 “PIM-G”
Filtered 740-011-20 “PIM-F” 740-011-20 “PIM-F” 740-011-20 “PIM-F” 740-011-20 “PIM-F”
Battery Wiring Kits 3-battery 30 Amp 874-001-20 “BWK-3” n/a n/a n/a
3-battery 50 Amp 874-001-21 “BWK-3HD” n/a n/a n/a
4-battery 30 Amp n/a 874-002-20 “BWK-4” n/a n/a
6-battery 30 Amp n/a n/a 874-003-20 “BWK-6” 874-003-20 “BWK-6”
6-battery 50 Amp n/a n/a 874-003-21 “BWK-6HD” 874-003-21 “BWK-6HD”
8-battery 30 Amp n/a n/a 874-004-20 “BWK-8” 874-004-20 “BWK-8”

Multilink Broadband Network Powering Products For Outside Plant 39

MULTILINK POWER SOURCE CATALOG.iSec1:39 Sec1:39 6/6/2007 12:45:32 PM


Pole Mount Life Saver Enclosures
PATENTED

030-043-10
030-016-10

Designed to house broadband power supplies and batteries in any pole-mounted application.
Standard features include durable construction with exterior finished in light equipment gray powder
paint. Custom colors are available upon request.
Open bottom design accommodates all vault-and-pad installations, allowing flexibility of utility and
cable entrance locations.
Totally enclosed design offers highest security from tampering or unauthorized entry, yet provides
flexibility in locating utility and cable entrance locations.
Battery slide trays lock in both closed and extended positions.
Front door is hinged for easy-open access, but is also removable for ease of installation and service of
enclosed equipment. Door is locked in the closed position with high-security latches.

Snow Screen Kit

Snow Screen Kit


Part # Description UOM
035-010-10 Severe Weather Cobra Vent Kit, 25” Narrow Enclosure Each
035-011-10 Severe Weather Cobra Vent Kit, 30” Wide Enclosure Each
035-031-10 Cobra Ridge Vent, Severe Weather Kit (Snow) Each

40 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:40 Sec1:40 6/6/2007 12:45:35 PM


. POLE MOUNT LIFE SAVER ENCLOSURE.

Pole Mount Enclosures / Life Saver


Part # 030-016-10 030-041-10 030-018-10 030-043-10
Model PM 3/4-N PM 4-W PM 6/8-N PM 8-W
Main Application Power Supply & Battery Power Supply & Battery Power Supply & Battery Power Supply & Battery
Enclosure Enclosure Enclosure Enclosure
Power Supply Shelf X X X X
Battery Shelf X X X X
Hinged Door X X X X
Ground Lug X X X X
Group 24 3 or 4 3 or 4 6 or 8 6 or 8
Group 27 or 31 3 3 or 4 6 6 or 8
AC Service External X X X X

Pole Mount Enclosures (Options Available)


Part # 030-016-10 030-041-10 030-018-10 030-043-10
Model PM 3/4-N PM 4-W PM 6/8-N PM 8-W
Main Application Power Supply & Battery Power Supply & Battery Power Supply & Battery Power Supply & Battery
Enclosure Enclosure Enclosure Enclosure
Life Saver Venting X X X X
Service Entrance 120V, 20A Standard 035-001-20 “SQD-1” 035-001-20“SQD-1” 035-001-20 “SQD-1” 035-001-20 “SQD-1”
120V, 20A Hi Inrush 035-001-11 “SQD-1HM” 035-001-11“SQD-1HM” 035-001-11 “SQD-1HM” 035-001-11 “SQD-1HM”
240V, 20A 1 Outlet 035-002-10 “SQD-2” 035-002-10 “SQD-2” 035-002-10 “SQD-2” 035-002-10 “SQD-2”
240V, 20A Dual Outlet 035-009-10 “SQD-3” 035-009-10 “SQD-3” 035-009-10 “SQD-3” 035-009-10 “SQD-3”
120V, 20A Duplex 035-007-10 “DOK-1” 035-007-10 “DOK-1” 035-007-10 “DOK-1” 035-007-10 “DOK-1”
240V, 15A Duplex 035-008-10 “DOK-2” 035-008-10 “DOK-2” 035-008-10 “DOK-2” 035-008-10 “DOK-2”
Indicators High Brightness 035-003-10 “ELK-1” 035-003-10 “ELK-1” 035-003-10 “ELK-1” 035-003-10 “ELK-1”
Economy 035-015-10 “ELK-E” 035-015-10 “ELK-E” 035-015-10 “ELK-E” 035-015-10 “ELK-E”
Single Light 035-036-20 “SIL-E” 035-036-20 “SIL-E” 035-036-20 “SIL-E” 035-036-20 “SIL-E”
Output Interfaces Economy 740-015-20 “PIM-E” 740-015-20 “PIM-E” 740-015-20 “PIM-E” 740-015-20 “PIM-E”
Standard 740-009-20 “PIM-G” 740-009-20 “PIM-G” 740-009-20 “PIM-G” 740-009-20 “PIM-G”
Filtered 740-011-20 “PIM-F” 740-011-20 “PIM-F” 740-011-20 “PIM-F” 740-011-20 “PIM-F”
Battery Wiring Kits 3-battery 30 Amp 874-001-20 “BWK-3” n/a n/a n/a
3-battery 50 Amp 874-001-21 “BWK-3HD” n/a n/a n/a
4-battery 30 Amp n/a 874-002-20 “BWK-4” n/a n/a
6-battery 30 Amp n/a n/a 874-003-20 “BWK-6” 874-003-20 “BWK-6”
6-battery 50 Amp n/a n/a 874-003-21 “BWK-6HD” 874-003-21 “BWK-6HD”
8-battery 30 Amp n/a n/a 874-004-20 “BWK-8” 874-004-20 “BWK-8”

Multilink Broadband Network Powering Products For Outside Plant 41

MULTILINK POWER SOURCE CATALOG.iSec1:41 Sec1:41 6/6/2007 12:45:38 PM


Low Density, Greater Efficiency, Small Footprint
Little Hawk Ground Mount Power Cabinets
500 VA and Under

18.5” W x 27.625” H x 24” D

Low Density, Small Footprint Application


Co-Locating Fiber Node / Power Supply
500 VA and Under

18.5” W x 39.25” H x 24” D

Part # Description
030-144-10 GM-PS-3 Mini 3 Battery Ground Mount Enclosure
030-142-10 GM-PSN-3 3 Battery Ground Mount / Fiber Node Enclosure

42 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:42 Sec1:42 6/6/2007 12:45:39 PM


. METERED POWER SUPPLY ENCLOSURE.
Metered Power Supply Enclosure

Designed to EUSERC standards; will accommodate either ring-type or ringless meter base.
In the MPC-Series cabinets, optional test/bypass blocks allow testing, servicing or replacement of the
internal kilowatt-hour meter without affecting utility service to the power supply.
Rainproof enclosure (Type 3R) will house broadband power supplies and batteries in ground-mounted
configuration.
May be used with pre-cast or poured-in-place concrete pads or vaults.
Open bottom design accommodates all vault-and-pad installations, allowing flexibility of utility and
cable entrance locations.
Standard features include durable construction with exterior finished in light equipment gray powder
paint. Custom colors are available upon request.
Battery slide trays lock in both closed and extended positions.
Separate lockable, sealed utility and cable compartments allow for craft separation and exclusive access.
Front and rear doors are removable for ease of installation and service of enclosed equipment. Doors are
locked in the closed position with high-security latches.

Please see ordering guide on the following page for the above unit and options

Multilink Broadband Network Powering Products For Outside Plant 43

MULTILINK POWER SOURCE CATALOG.iSec1:43 Sec1:43 6/6/2007 12:45:46 PM


Metered Power Enclosures - Standard
Part # 030-048-10 030-048-11 T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. T.B.D.
Model MPC-3 MPC-3 MPC-4 MPC-6 MPC-8 MPC-8 MPC3-Basic MPC4-Basic MPC6-Basic
Main Entrance Power Power Power Power Power Power Power Power Power
Supply & Supply & Supply & Supply & Supply & Supply & Supply & Supply & Supply &
Battery Battery Battery Battery Battery Battery Battery Battery Battery
Enclosure Enclosure Enclosure Enclosure Enclosure Enclosure Enclosure Enclosure Enclosure
(NOTE 1)
Overall Dimensions 46.1”H x 46.2”H x 46.2”H x 50.1”H x 50.1”H x 50.1”H x 46.1” H x 46.2” H x 50.1” H x
28”W x 28”W x 33.6”W x 28”W x 33.6”W x 33.6”W x 28”W x 33.6”W x 28”W x
21.3”D 21.3”D 21.3”D 21.3”D 21.3”D 21.3”D 21.3”D 21.3”D 21.3”D
Power Supply Shelf X X X X X X X X X
Battery Shelf X X X X X X X X X
Hinged Roof X X X X X X X X X
Hinged Doors
Drop-in Doors X X X X X X X X X
Ground Lug X X X X X X X X X
Internal X X X X X X
External
Group 24 3 3 4 6 8 8 3 4 6
Group 27 or 31 3 3 4 6 8 8 3 4 6
240V 20A / Ext X
Dual 120V, 20A / Int X X X X X
Single, Ext. 120V, 20A Hi In Rush
240C, 20A Duplex 120V, 20A X X X X X X
Duplex Dual Outlets
120V, 20A Duplex Single Outlet
Standard Features Legend: “X” Standard equipment or feature provided in enclosure
(NOTE 1): This product listed to UL Standard 1012 for Power Units other than Class 2

Metered Power Enclosures - Options


Part # 030-048-10 030-048-11 T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. T.B.D. T.B.D.
Model MPC-3 MPC-3 MPC-4 MPC-6 MPC-8 MPC-8 MPC-3 Basic MPC-4 Basic MPC-6 Basic
Main Entrance Power Power Power Power Power Power Power Power Power
Supply & Supply & Supply & Supply & Supply & Supply & Supply & Supply & Supply &
Battery Battery Battery Battery Battery Battery Battery Battery Battery
Enclosure Enclosure Enclosure Enclosure Enclosure Enclosure Enclosure Enclosure Enclosure
(NOTE 1) (NOTE 1)
Overall Dimensions 46.1”H x 46.2”H x 46.2”H x 50.1”H x 50.1”H x 50.1”H x 46.2”H x 46.2”H x 50.1”H x
28.”W x 28.”W x 33.6”W x 28.”W x 33.6”W x 33.6”W x 28.”W x 33.6”W x 28.”W x
21.3”D 21.3”D 21.3”D 21.3”D 21.3”D 21.3”D 21.3”D 21.3”D 21.3”D
Test/Bypass Blocks Fifth Jaw X X X X X X
for KwH Meter
High Brightness ELK-1 035-003-10 035-003-10 035-003-10 035-003-10 035-003-10 035-003-10 035-003-10 035-003-10 035-003-10
Economy ELK-E 035-015-10 035-015-10 035-015-10 035-015-10 035-015-10 035-015-10 035-015-10 035-015-10 035-015-10
Single Light SIL-E 035-036-20 035-036-20 035-036-20 035-036-20 035-036-20 035-036-20 035-036-20 035-036-20 035-036-20
Economy PIM-E 740-015-20 740-015-20 740-015-20 740-015-20 740-015-20 740-015-20 740-015-20 740-015-20 740-015-20
Standard PIM-G 740-009-20 740-009-20 740-009-20 740-009-20 740-009-20 740-009-20 740-009-20 740-009-20 740-009-20
Filtered PIM-F 740-011-20 740-011-20 740-011-20 740-011-20 740-011-20 740-011-20 740-011-20 740-011-20 740-011-20
3-battery 30 Amp BWK-3 874-001-20 874-001-20 n/a n/a n/a n/a 874-001-20 n/a n/a
3-battery 50 Amp BWK-3HD 874-001-21 874-001-21 n/a n/a n/a n/a 874-001-21 n/a n/a
4-battery 30 Amp “BWK-4” n/a n/a 874-002-20 n/a n/a n/a n/a 874-002-20 n/a
6-battery 30 Amp “BWK-6” n/a n/a n/a 874-003-20 n/a n/a n/a n/a 874-003-20
6-battery 50 Amp “BWK-6HD” n/a n/a n/a 874-003-21 n/a n/a n/a n/a 874-003-21
8-battery 30 Amp “BWK-8” n/a n/a n/a n/a 874-004-20 874-004-20 n/a n/a n/a
Standard Features Legend: “X” Standard equipment or feature provided in enclosure

44 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:44 Sec1:44 6/6/2007 12:45:49 PM


. CUSTOM METERED POWER SUPPLY CABINETS.
Additional Battery Storage Cabinets

Lockable bar to install a pad lock


to stop battery bandits

Meter Cabinet Battery Cabinet

Custom Cabinets to fit your


needs can retrofit to
existing power cabinets

Hasp Lock

Multilink Broadband Network Powering Products For Outside Plant 45

MULTILINK POWER SOURCE CATALOG.iSec1:45 Sec1:45 6/6/2007 12:45:50 PM


Power Supply Additional Battery
Cabinet PS2-8 Storage Cabinet

2 x 100 CFM Fans


Equipped With A
Thermostat

Item # Part # Description


1 030-130-10 MPC-PS2-8 120/240V Gray Assy
2 030-131-10 6 Battery Enclosure 18 x 52 x 22 Assy

Part # Description
016-022-20 Power Supply Non-Standby 60HZ
W/O Enclosure 1350-1206-60/90

46 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:46 Sec1:46 6/6/2007 12:45:53 PM


. BATTERY ENCLOSURES.
6 Battery Enclosure

Part # Description Dimensions UOM


030-131-10 6 Battery Enclosure / Gray 18”W x 52”H x 22”D Each

BSU3-164210 Battery Storage Unit

Part # Description Dimensions UOM


030-145-10 BSU3-164210 Battery Storage Unit Lt Green 16”W x 42”H x 10”D Each

Multilink Broadband Network Powering Products For Outside Plant 47

MULTILINK POWER SOURCE CATALOG.iSec1:47 Sec1:47 6/6/2007 12:45:59 PM


BSU2-162710 Battery Storage Unit

Part # Description Dimensions UOM


030-149-10 BSU2-162710 Battery Storage Unit Gray 16”W x 27”H x 10”D Each

BSU4-182715 Battery Storage Unit

Part # Description Dimensions UOM


030-156-10 BSU4-182715 Battery Storage Unit Gray Assembly 18”W x 26”H x 15”D Each

Battery Enclosure (Bottom Add-On)

Part # Description Dimensions UOM


- Battery Enclosure ( Bottom Add-On ) 25”W x 11”H x 16”D Each

48 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:48 Sec1:48 6/6/2007 12:46:01 PM


. BATTERY ENCLOSURES.
Battery Storage Units
Part # 030-149-10 030-145-10 TBD 030-156-10 030-131-10 030-029-10 030-131-20 030-115-20 030-030-10
Model # BSU-2 BSU-3 BSU-3 BSU-4 BSU-6 BSU-8 BSU-9 BSU-12 BSU-12
Width 16" 16" 25" 18" 18" 36" 18" 31.3" 36"
Height 27" 42" 11" 27" 22.5" 30.25" 22.5" 46" 35"
Depth 10" 10" 16" 15" 52" 23" 52" 20.5" 23"
Slide Out Trays - - 1 - - 2 - 3 2
Fixed Trays 2 3 - 2 2 - 3 - -
Group 24 2 3 4 4 8 10 12 12 16
Group 27 or 31 2 3 3 4 6 8 9 12 12
Steel Exterior X X Available X - - - - -
Aluminum Exterior - - Available - X X X X X
Dual Access ( Note 1 ) - - - - X X X X X
Security Bar - - - - - - - 2 -
Pole Mount (PM) PM See Note 2 See Note 2 PM - - - - -
Ground Mount (GM) - See Note 2 See Note 2 - X X X X X
Flat Roof - - X - - - - X -
LF SVR Roof ( Note 3 ) X X - X X X X - X
Note 1: Front & Rear Access Doors
Note 2: Cabinet Mnt. Also Available With Optional Pm/gm Accessories
Note 3: Life Saver Slope/Angled Roof Assists Natural Convection

Multilink Broadband Network Powering Products For Outside Plant 49

MULTILINK POWER SOURCE CATALOG.iSec1:49 Sec1:49 6/6/2007 12:46:04 PM


Standby AC/DC Generator For Broadband Networks
TECHNICAL DATA

Honda Portable AC/DC Generators For Broadband Networks


While head-end services may be adequately protected against long-term power outages by large standby
generators, critical nodes and power supply points in the outside plant are often at the mercy of battery reserve
time for standby power needs. Most standby power supplies within the cable system may operate for about two or
three hours on battery reserve before automatic shutdown protects them against the harmful effects of low battery
voltage. Although these system operating characteristics may not be objectionable for video-only delivery, the more
critical needs for power in VoIP, telephony and data delivery systems may be met more easily through the use of
standby generators during extended commercial power failures.

Multilink offers the convenience of providing an easily transportable standby generator suitable for use as a power
source with its products. This generator has been tested in trials with our MP900, MP1350 and MPS1350 products and
found to be an adequate standby AC/DC source for these applications.

Generator Specifications Include


Continuous power rating of 6.6KW with both 120 and 240 volt outlets
Circuit breakers and outlets located on an easily accessible control panel
13 horsepower gasoline fueled engine, air cooled; electric start
Low oil shutoff protection
Tubular steel frame with wheels and fold-down handles for ease of transport
Approximate size: 22.25” H x 23.63” W x 31.75” D
Approximate weight: 220 pounds
6.5 gallon fuel capacity

Part # Description
041-005-10 Generator Portable 3KW 36VDC Gasoline
041-006-10 Generator 5KW 36VDC

50 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:50 Sec1:50 6/6/2007 12:46:05 PM


. STANDBY GENERATOR.
Smart Breaker

The Smart Breaker continuously monitors the cable plant current draw. When a fault causes the load current to exceed a
programmable threshold, the Smart Breaker quickly disconnects the cable plant from the power supply, thereby protecting
both the plant and power supply from overload damage. After a short interval, the Smart Breaker will attempt to reapply
power and restore normal plant operation. If the fault has cleared, the Smart Breaker will restore plant power and continue to
monitor the current draw. Should a fault continue to exist, the Smart Breaker will try to restart the cable plant a programmed
number of times before shutting down and aborting any further attempts to restore power. The quick acting disconnect action
of the Smart Breaker reduces power supply output fuse stress and can reduce or eliminate the problem of fuse failure and
attendant maintenance problems triggered by brief accidental plant short circuits. The Smart Breaker is compatible with any
60V or 90V Standby or UPS power supply supporting a load of 20A or less.

Electronic overload protection for any CATV standby or UPS


User selectable current thresholds
User selectable re-closure attempts
60V and 90V compatible

Part # Description Dimensions UOM


744-216-20 Smart Breaker Kit (Includes wiring harness) 6.5” W x 2.5” H x 8” D Each
870-104-21 Power Supply to Smart Breaker Harness 18” Long Each

Multilink Broadband Network Powering Products For Outside Plant 51

MULTILINK POWER SOURCE CATALOG.iSec1:51 Sec1:51 6/6/2007 12:46:05 PM


Surge Suppression
Ground it, Bond it and Protect it.
Critical protection from voltage transients coming from the utility line, cable plant and noises.

52 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:52 Sec1:52 6/6/2007 12:46:06 PM


. SURGE SUPPRESSION.

Coaxial line surge suppression for modems and transponders


connected via RG-6 or RG-59 cable. This device provides
added protection for sensitive communication equipment
when used in conjunction with surge suppression in the
163-001-10 balance of the cable plant.

High current surge protection for use with individual power


supplies. Models available for 120 or 240 VAC applications, up
to 20amps current ratings. Excellent primary surge protection
that can be added to any power supply installation.
163-002-10

Plug in surge suppression for use in 120 volt duplex outlets.


Provides localized surge protection of the particular outlet of
connection. This device provides additional secondary surge
protection where primary protection at the service entrance
163-003-10 or branch circuit panel has be employed.

Output surge protection rated for 60 or 90 volts AC


connected to the output of a cable power supply. Provides
protection against surges originating on the cable resulting
163-004-10 from distant lightning strikes or side flashes.
163-004-11

Primary surge protection, suitable for installation in service


entrance boxes or branch circuit panels. This device can
be used in both new builds and in upgrades or retrofit
applications. Available for 120 or 240 volt use with mechanical
163-005-10 mounting suitable for standard 7/8 inch knockout.

Multilink Broadband Network Powering Products For Outside Plant 53

MULTILINK POWER SOURCE CATALOG.iSec1:53 Sec1:53 6/6/2007 12:46:09 PM


744-379-20

Automatically switches from the primary utility grid to a second utility grid in case of a
power failure. The second source preserves the battery charge until both utility sources
fail. Indicator light shows status of both primary and secondary source.

Part # Description
744-379-20 Dual Source Switch

54 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:54 Sec1:54 6/6/2007 12:46:11 PM


. SURGE PROTECTION.

Part # Description UOM


874-001-20 BWK-3 Battery Wiring Kit 3 Battery Each

874-001-21 BWK-3HD Battery Wiring Kit 3 Battery Heavy Duty Each

874-002-20 BWK-4 Battery Wiring Kit 4 Battery Each

874-003-20 BWK-6 Battery Wiring Kit 6 Battery Each

874-003-21 BWK-6HD Battery Wiring Kit 6 Battery Heavy Duty Each

874-008-20 BWK-8 Battery Wiring Kit 8 Battery Each

Multilink Broadband Network Powering Products For Outside Plant 55

MULTILINK POWER SOURCE CATALOG.iSec1:55 Sec1:55 6/6/2007 12:46:14 PM


Part # Description UOM
Service Entrance Kits
035-001-11 SQD-1 HM 120V Service Entrance Each
035-001-20 SQD-1 Breaker Box 120V 20A Each
035-002-10 SQD-2 Service Entrance Kit 240V W/20A Breaker Each
035-009-10 SQD-3 HM 120/240V Service Entrance Each

Power Insertion Modules


740-009-20 PIM-G with 4’ Cable Each
740-015-20 PIM-E Economy PIM Each

Multifunction Power Insertion Module (PIM) supports output load current


connection to the cable coaxial fittings leading to the system power inserter via
a standard 5/8” threaded fitting. Status monitor connection permits monitoring
of output AC voltage and power of transponders. (Powering of status monitoring
transponders by direct DC connection to the batteries may unbalance charge
distribution across the battery string, reducing battery life. Multilink supports
a separate DC power supply for monitoring transponders, powered by an AC
output at the PIM.) A convenient power substitution switch allows transfer to
a service power supply when removing or upgrading the UPS module, with a
minimum interruption to plant powering.

Outlet Kits
035-007-10 DOK-1 Duplex Outlet Kit 120V Each
035-008-10 DOK-2 Duplex Outlet Kit 240V Each

Other Cabinet Options


523-003-10 100 Amp Outdoor Meter Base; Milbank Ring Type Each
523-202-10 Meter Base 200 Amp/250VAC; Ringless Each
523-203-10 100 Amp Meter Base-Milbank; Ring Type, Series U-125 Each
802-003-10 Polymer Mounting Pad (For all MQ Cabinets & FNC-2000) 42” x 42” Each
802-001-10 Polymer Mounting Pad (For FNC-2000 & FNC-3000) 25” x 38” Each
740-008-20 Tamper Switch Kit Each
035-017-10 Mounting Kit & Template for MQ35 ONLY (Not Pictured) Each

Battery Blanket
TBD Battery Blanket Each

Light Kits
035-003-10 ELK-1 Enclosure Light Kit Each
035-014-20 Enclosure Light Kit (Lectro Option) Each
035-015-10 Economy Enclosure Light Kit ELK-1E Each
035-016-20 ALK-1 Standby Light Kit (Alpha Option) Each
035-036-20 ALK-1 SIL-E Standby Light Kit (Economy) Each

Cabinet Fan Cooling Kit


035-025-10 MQ-FK1 (for MQ-36 cabinets) Each

Snow Screen Kit


035-010-10 Severe Weather Cobra Vent Kit, 25” Narrow Enclosure Each
035-011-10 Severe Weather Cobra Vent Kit, 30” Wide Enclosure Each
035-031-10 Cobra Ridge Vent, Severe Weather Kit (Snow) Each

56 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:56 Sec1:56 6/6/2007 12:46:17 PM


. POWER CABINET ACCESSORIES & OPTIONS.
Opto-Electronic Enclosure
Product Description
Multilink’s Opto-Electronic Enclosure is designed for 19” &
23” rack mounted equipment. The enclosure is designed
to protect the equipment from dust, snow, and rain. It is
equipped with two duplex GFI outlets, a fluorescent light
that gets activated by an automatic pressure switch when
the door opens. The internal rack is 52” high (29 Rack Units).
Also equipped with a solar shield installed above the roof for
additional protection from sun loading.

General Specifications
Dimensions 28” W x 65” H x 83.82” D
(71.12cm x 165.1cm x 77.47cm)
Weight 230 lbs. (104.3kg)

Construction
Material Durable Aluminum Construction
(3003 H-14 ALUM)
Hardware Stainless Steel Hardware
Finish Polyethylene Powder Coat
Security 3-Point Latching System

Part # Description Dimensions Weight (lbs) UOM


030-129-10 Opto-Electronic Enclosure 28” W x 65” H x 33” D 230 Each

1 RU 600 CFM Fan Shelf


Product Description
Multilink’s Fan Shelf is designed for both 19” & 23” rack
configurations. It provides a massive airflow of 600 CFM.
This unique design enables an automatic activation and
deactivation of the fans at 100° F and at 90° F respectively.
The Fan Shelf operates on 120V AC and is also equipped with
a 15 Amp circuit breaker switch (conveniently located towards
the front) and a 10 ft. power cord for convenient use in any
sized enclosure. Included with the Fan Shelf is a universal
mounting kit with required hardware to enable 19” or a 23”
configuration.

General Specifications
Dimensions 17” W x 1.75” H x 14.84” D
Weight 14 lbs. (6.35kg)

Construction
Material Durable Aluminum construction
(3003 H-14 ALUM)
Hardware Stainless Steel hardware
Finish Polyethylene powder coat

Part # Description Dimensions Weight (lbs) UOM


744-386-20 600 CFM Fan Shelf 28” W x 1.75” H x 14.84” D 14 Each

Multilink Broadband Network Powering Products For Outside Plant 57

MULTILINK POWER SOURCE CATALOG.iSec1:57 Sec1:57 6/6/2007 12:46:20 PM


SmartPed 2000-FNC
Application
An above-ground housing to shelter amplifiers, splice
enclosures, nodes, and provide ample space for slack storage
in a secured environment.

Pedestal consists of one piece continuous frame made up of


galvanealed steel and a top, four doors and skirts made
up of galvanealed steel.
Pedestal parts are coated with 2-3 mils of polyester
powder coat after undergoing 5 pretreatment processes.
All four doors and top are detachable using stainless steel
slide off hinges (8).
Front doors are locked with a rod-roller system
including a flush mounted 1 piece lock.
Back doors are also locked internally and can
only be accessed from inside the pedestal.
All door ventilation louvers are backed with
fiberglass bug screens.
Convection air flow system in place to properly
ventilate cabinet.
Pedestal can either be concrete pad mounted,
stake mounted, or vault mounted.
All vertical seams are sealed with synthetic
rubber seal. Entire cabinet is rain tight.
Built-in universal mounting hardware and
accessories made of galvaneal with polyester
powder coat to withstand all environments.
Safety Corners™.

Part # Description Dimensions UOM


12467K 2000-FNC Node Cabinet and Pedestal Base, includes two mounting rods 50”H x 30”W x 16”D Each
and slack storage brackets
12824 BS-24 Stake 24” Long Each
12432 BS-32 Stake 32”Long Each

12845 BS-48 Stake 48” Long Each

Customize internal SmartPed components to fit your broadband needs. Call Customer Service for more information. (440.366.6966)

58 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:58 Sec1:58 6/6/2007 12:46:22 PM


. ABOVE GROUND CABINETS.
SmartPed 3000-FNC

Application
An above-ground housing to shelter amplifiers, splice
enclosures, nodes, and provide ample space for slack storage
in a secured environment.

Pedestal consists of a one piece continuous frame made up


of galvanealed steel; a top, four doors, and skirts made
up of galvanealed steel.
Pedestal parts are coated with 2-3 mils of polyester powder
coat after undergoing 5 pre-treatment processes.
All door ventilation louvers are backed with fiberglass bug
screens.
Convection air flow system in place to properly ventilate
cabinet.
Pedestal can either be concrete pad mounted, stake
mounted, or vault mounted.
All vertical seams are sealed with synthetic rubber seal.
Entire cabinet is rain tight.
Built-in universal mounting hardware and accessories made
of galvaneal with polyester powdercoat to withstand all
environments.
50”H x 30’W x 35”D
Safety Corners™.

Multilink Broadband Network Powering Products For Outside Plant 59

MULTILINK POWER SOURCE CATALOG.iSec1:59 Sec1:59 6/6/2007 12:46:24 PM


SmartPed 3000-FNC
Standard Features
Gray Powder Coat Finish

Optional colors available. Please call Customer


Service for a complete list of available colors

Part # Description Dimensions UOM


030-150-11 Power Supply Node Enclosure includes power supply shelf, one battery slide out tray, two brackets to hang 36”H x 30”W x 35”D Each
nodes and fiber optic storage. This enclosure has the capability to hold 3 Group 24,27, or 31 batteries.
Varies w/Options Power Supply Node Enclosure includes power supply shelf, one battery slide out tray, two brackets to hang 50”H x 30”W x 35”D Each
nodes and fiber optic storage. This enclosure has the capability to hold 3 Group 24,27, or 31 batteries.
Varies w/Options Power Supply Node Enclosure includes power supply shelf, two battery slide out tray, two brackets to hang 50”H x 30”W x 35”D Each
nodes and fiber optic storage. This enclosure has the capability to hold 6 Group 24,27, or 31 batteries.
Varies w/Options Power Supply Node Enclosure includes power supply shelf, three battery slide out tray, two brackets to 50”H x 30”W x 35”D Each
hang nodes and fiber optic storage. This enclosure has the capability to hold 9 Group 24,27, or 31 batteries.
Varies w/Options Power Supply Cabinet Enclosure includes power supply shelf and one battery slide out tray. This enclosure 50”H x 30”W x 16”D Each
has the capability to hold 3 group 24,27, or 31 batteries.
Varies w/Options Power Supply Cabinet Enclosure includes power supply shelf and two battery slide out tray. This enclosure 50”H x 30”W x 16”D Each
has the capability to hold 6 group 24,27, or 31 batteries.
Varies w/Options Power Supply Cabinet Enclosure includes power supply shelf and three battery slide out tray. This 50”H x 30”W x 16”D Each
enclosure has the capability to hold 9 group 24,27, or 31 batteries.
12824 BS-24 Stake 24” Long Each
12432 BS-32 Stake 32”Long Each
12845 BS-48 Stake 48” Long Each

60 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:60 Sec1:60 6/6/2007 12:46:26 PM


. UNDERGROUND CABINETS.
Underground Vaults & Battery Vaults

Multilink Broadband Network Powering Products For Outside Plant 61

MULTILINK POWER SOURCE CATALOG.iSec1:61 Sec1:61 6/6/2007 12:46:26 PM


Dry Box™ Water Proof, Underground Battery Housing

Protect Your Batteries With The Dry Box™


Stores 3-4 Group 31 Batteries
Lock with Standard Hex Head or Tamper Proof Screw
Batteries are accessible by opening pad cover to access battery cover
Dry Box is made of Chemical Resistant Material

Part # Description Dimensions Weight (lbs) UOM


800-019-20 Dry Box For 3 Group 31 15-1/2” W x 24-1/4” L x 13-1/2” D 75 Each
800-011-20 Dry Box For 4 Group 31 15-1/2” W x 28-1/4” L x 13-1/2” D 75 Each
T.B.D. Dry Box For Pad-3 24” W x 35” L x 12” D 75 Each

T.B.D. Dry Box For Pad-4 24” W x 40” L x 12” D 75 Each

- Bilge Pump For 12 Volt n/a 1 Each

62 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:62 Sec1:62 6/6/2007 12:46:27 PM


. DRY BOX.
Multilink Vaults And Pads

B C

Part # Description Dimensions Weight (lbs) UOM


Vaults Only
A 800-001-10 2436-18 HDPE Vault 24” x 36” x 18” 41 Each
800-003-10 1730-15 HDPE Vault 17” x 30” x 15” 24 Each
800-005-10 1730-18 HDPE Vault 17” x 30” x 18” 26.5 Each
Mounting Pad
B 802-007-10 Pad for MQ-30 & MQ35 (C3040-3MP2) 30” x 40” x 3” 135 Each
802-008-10 Pad for MQ-36 & MQ35 (C3030-3MP33) 30” x 40” x 3” 135 Each
802-009-10 Pad for GM 3/4 & Narrow, GM 6/8 & Narrow, GM 3,4,6,8 36” x 36” x 3” 146 Each
802-011-10 Pad for Power Cabinet Concrete Pole 120” x 8” x 8” 650 Each
802-015-10 Pad for MPC-3 & MPC-6 (Internal Meter Enclosure) 48” x 36” x 3” 195 Each
802-017-10 Pad for FNC-2000 & 3000-5016 w/ inserts 42” x 42” x 3” 199 Each
Vaults And Lid Kits
C 801-001-20 2436-18 HDPE Vault, Lid & Hardware, Light Duty, Gray 24” x 36” x 20” 55 Each
801-002-20 3636-18 HDPE Vault, Lid & Hardware, Light Duty, Gray 36” x 36” x 20” 71.5 Each
801-003-20 1730-18 HDPE Vault, Lid & Hardware, Light Duty, Green 17” x 30” x 20” 36.1 Each
801-005-20 1017-12 HDPE Vault, Lid & Hardware, Light Duty, Gray 10” x 17” x 14” 11 Each

Multilink Broadband Network Powering Products For Outside Plant 63

MULTILINK POWER SOURCE CATALOG.iSec1:63 Sec1:63 6/6/2007 12:46:28 PM


MQ Series Low Profile Cabinets
All In One Cabinet

Co-Locating Fiber Node And Power Supply Cabinet


In One Cabinet

Tamper Switch For


Status Monitoring
Fiber Optic Closure

Fiber Node

DC or Line TAP

Front of Cabinet

Power Supply

Battery Storage

Back of Cabinet

64 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:64 Sec1:64 6/6/2007 12:46:29 PM


. MQ SERIES CABINETS.
MQ-Series Enclosures
Low Density, Greater Efficiency, Small Footprint
MQ Enclosure Accessories
Fiber Node/Slack Storage Enclosures
Battery Enclosures
Battery & Power Supply Enclosures
Racking/Universal Enclosures
Battery Vaults and SmartPeds

Designed to house broadband power supplies, batteries, nodes, and fiber terminations in any
ground-mounted configuration. Options available allow for extremely flexible applications for
cable or fiber plants.
Patented ventilation design allows for increased exchange of air within the enclosure as compared to
traditional ventilation arrangements. Interior equipment and batteries operate in a significantly
cooler environment, thus increasing life spans.
May be used with pre-cast or poured-in-place concrete pads, vaults, or any other desired mounting
options.
Open bottom design accommodates all vault and pad installations, allowing flexibility of utility and
cable entrance locations.
Standard features include durable, all-aluminum construction with exterior finished in light
equipment gray powder coat paint. Custom colors are available upon request.
Battery slide trays lock in both closed and extended positions.
Front and rear doors are removable for ease of installation and service of enclosed equipment.
Doors are locked in the closed position with high-security latches.

Multilink Broadband Network Powering Products For Outside Plant 65

MULTILINK POWER SOURCE CATALOG.iSec1:65 Sec1:65 6/6/2007 12:46:29 PM


Slack Storage Enclosures

MQ-SS2-1 Fiber Node


Slack Storage Enclosure
Shown With Optional Equipment Installed

Base Enclosure
Standard enclosure is gray powder coat
finish, optional colors are available. Please
call Customer Service for more information.
Enclosure includes brackets to hang nodes,
velcro straps to secure slack and drop in
doors with locks.

Part # Description Dimensions UOM


030-025-10 Gray Node Enclosure 36”W x 30.26”H x 23” D Each

MQ-SS2-2 Fiber Node


Slack Storage Enclosure
Shown With Optional Equipment Installed

Base Enclosure
Standard enclosure is gray powder coat
finish, optional colors are available. Please
call Customer Service for more information.
Enclosure includes brackets to hang nodes,
velcro straps to secure slack and drop in
doors with locks.

Part # Description Dimensions UOM


030-028-10 Gray Fiber Node Slack Storage Enclosure 36”W x 35.97”H x 25” D Each

MQ-35N Fiber Node


Slack Storage Enclosure
Shown With Optional Equipment Installed

Base Enclosure
Standard enclosure is gray powder coat
finish, optional colors are available. Please
call Customer Service for more information.
Enclosure includes brackets to hang nodes,
velcro straps & slack hooks to secure slack
and drop in doors with locks.

Part # Description Dimensions UOM


030-045-10 Gray Fiber Node Slack Storage Enclosure 36”W x 35.00”H x 23” D Each

66 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:66 Sec1:66 6/6/2007 12:46:30 PM


. MQ SERIES CABINETS LOW PROFILE.
Fiber Node Enclosures - Standard
Part # 030-025-10 030-028-10 030-045-10
Model MQ-SS2-1 MQ-SS2-2 MQ-35N
Main Application Fiber Node & Slack Storage Fiber Node & Slack Storage Fiber Node & Slack Storage
Overall Dimensions 30.3”H x 36”W x 23”D 36”H x 36”W x 25”D 35”H x 36”W x 23”D
Internal Relay Rack - - -
Power Supply Shelf - - -
Battery Shelf - - -
Life Saver Venting X X X
Drop-In Doors X X X
Ground Lug X X X
Fastening Brackets X X X
Internal Straps X X X
Group 24 - - -
Group 27 or 31 - - -
AC Service External - - -
AC Service Internal - - -
Standard Features Legend: “X” Standard equipment or feature provided in enclosure

Multilink Broadband Network Powering Products For Outside Plant 67

MULTILINK POWER SOURCE CATALOG.iSec1:67 Sec1:67 6/6/2007 12:46:34 PM


Slack Storage Enclosures
MQ-B8 & MQ-B12
Battery Enclosure
Shown With Optional Equipment Installed
Base Enclosure
Standard enclosure is gray powder coat
finish, optional colors are available.
Please call Customer Service for more
information. Enclosure includes 2 battery
trays, drop in doors with locks.
Part No. 030-029-10
This enclosure has the capability to hold 8
group 24, 27, or 31 batteries.
Part No. 030-030-10
This enclosure has the capability to hold 12
group 27, 31 batteries or 16 group 24, 27,
31 batteries.

Part # Description UOM


030-029-10 Gray Battery Enclosure Each
030-030-10 Gray Battery Enclosure Each

Battery Enclosures - Standard


Part # 030-029-10 030-030-10
Model MQ-B8 MQ-B12
Main Application Battery Enclosure Battery Enclosure
Overall Dimensions 30.3”H x 36”W x 23”D 30.3”H x 36”W x 23”D
Internal Relay Rack - -
Power Supply Shelf - -
Battery Shelf X X
Life Saver Venting X X
Drop-In Doors X X
Ground Lug X X
Fastening Brackets - -
Internal Straps - -
Group 24 8 16
Group 27 or 31 8 12
AC Service External - -
AC Service Internal - -
Standard Features Legend: “X” Standard equipment or feature provided in enclosure

Battery Enclosures - Options


Part # 030-029-10 030-030-10
Model MQ-B8 MQ-B12
Main Application Battery Enclosure Battery Enclosure
Overall Dimensions 30.3”H x 36”W x 23”D 30.3”H x 36”W x 23”D
Enclosure Fan Cooling 035-004-20 “EFC-1” 035-004-20 “EFC-1”
8-battery 30 Amp 874-004-20 “BWK-8” 874-004-20 “BWK-8”
12-battery 30 Amp n/a 874-009-20 “BWK-12”
12-battery 30A Fused n/a 874-010-20 “BWK-12F”
Standard Features Legend: “X” Standard equipment or feature provided in enclosure

68 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:68 Sec1:68 6/6/2007 12:46:34 PM


. MQ SERIES CABINETS LOW PROFILE.
Battery Enclosure Exterior Service Only
MQ-PS2-4 Power Supply
Battery Enclosure
Exterior Service Only
Shown With Optional Equipment Installed
Base Enclosure
Standard enclosure is gray powder coat
finish, optional colors are available. Please
call Customer Service for more information.
Enclosure includes power supply shelf, battery
tray, drop in doors with locks and ground lug.
This enclosure has the capability to hold 4
group 24 or 31 batteries.

Part # Description Dimensions UOM


030-027-10 Gray Power Supply Enclosure 36”W x 30.26”H x 23” D Each

MQ-PS2-6 Power Supply


Battery Enclosure
Exterior Service Only
Shown With Optional Equipment Installed
Base Enclosure
Standard enclosure is gray powder coat
finish, optional colors are available. Please
call Customer Service for more information.
Enclosure includes power supply shelf, battery
tray, drop in doors with locks and ground lug.
This enclosure has the capability to hold 8
group 24 or 6 group 27 or 31 batteries.

Part # Description Dimensions UOM


030-024-10 Gray Power Supply Enclosure 36”W x 30.26”H x 23” D Each

MQ-PS2-8 Power Supply


Battery Enclosure
Exterior Service Only
Shown With Optional Equipment Installed
Base Enclosure
Standard enclosure is gray powder coat
finish, optional colors are available. Please
call Customer Service for more information.
Enclosure includes power supply shelf,
battery tray, drop in doors with locks, and
ground lug. This enclosure has the capability
to hold 8 group 24, 27, or 31 batteries.

Part # Description Dimensions UOM


030-045-10 Gray Power Supply Enclosure 36”W x 35.97”H x 25” D Each

Please see options list and accessories page to specify components and other products you may need

Multilink Broadband Network Powering Products For Outside Plant 69

MULTILINK POWER SOURCE CATALOG.iSec1:69 Sec1:69 6/6/2007 12:46:36 PM


Battery Enclosure Exterior Service Only
MQ-PS2-12 Power Supply
Battery Enclosure
Exterior Service Only
Shown With Optional Equipment Installed
Base Enclosure
Standard enclosure is gray powder coat
finish, optional colors are available. Please
call Customer Service for more information.
Enclosure includes power supply shelf, 2
battery trays, drop in doors with locks, and
ground lug. This enclosure has the capability
to hold 16 group 24 or 12 group 27 or 31
batteries.

Part # Description Dimensions UOM


030-033-10 Gray Power Supply Enclosure 36”W x 35.97”H x 25 D Each

MQ-PSN-4 Power Supply


Battery / Node Enclosure
Exterior Service Only
Shown With Optional Equipment Installed
Base Enclosure
Standard enclosure is gray powder coat
finish, optional colors are available. Please
call Customer Service for more information.
Enclosure includes power supply shelf, battery
tray, drop in doors with locks, 2 rods to hang
nodes & other system equipment from, 4
velcro straps to secure slack storage, and a
ground lug. This enclosure has the capability
to hold 4 group 24, 27, or 31 batteries.

Part # Description Dimensions UOM


030-032-10 Gray Power Supply Node Enclosure 36”W x 35.97”H x 25” D Each

MQ-PSN-8 Power Supply


Battery / Node Enclosure
Exterior Service Only
Shown With Optional Equipment Installed
Base Enclosure
Standard enclosure is gray powder coat
finish, optional colors are available. Please
call Customer Service for more information.
Enclosure includes power supply shelf, battery
tray, drop in doors with 2 locks, rods to hang
nodes & other system equipment from, 4
velcro straps to secure slack storage, and a
ground lug. This enclosure has the capability
to hold 8 group 24, 27, or 31 batteries.

Part # Description Dimensions UOM


030-026-10 Gray Power Supply Node Enclosure 36”W x 35.97”H x 25” D Each

Please see options list and accessories page to specify components and other products you may need

70 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:70 Sec1:70 6/6/2007 12:46:40 PM


. MQ SERIES CABINETS LOW PROFILE.
Battery Enclosure With Interior Service
MQ-35-IS (PS2-6) Power Supply
Battery Enclosure With
Interior Service
Shown With Optional Equipment Installed
Slack Storage Can Be Bolted Together W/ Power
Base Enclosure
Standard enclosure is gray powder coat
finish, optional colors are available. Please
call Customer Service for more information.
Enclosure includes power supply shelf,
battery tray, drop in doors with locks, and
ground lug. This enclosure will accommodate
interior service disconnect. This enclosure has
the capability to hold 8 group 24 or 6 group
27 or 31 batteries.

Part # Description Dimensions UOM


030-044-10 Gray Power Supply Enclosure 36”W x 35.00”H x 23” D Each

MQ-40-IS (PS2-6) Power Supply


Battery Enclosure With
Interior Service
Shown With Optional Equipment Installed
Base Enclosure
Base Enclosure-Standard enclosure is gray
powder coat finish, optional colors are
available. Please call Customer Service for
more information. Enclosure includes power
supply shelf, battery tray, drop in doors
with 2 locks, rods to hang nodes & other
system equipment from, 4 velcro straps to
secure slack storage, and a ground lug. This
enclosure has the capability to hold 8 group
24, 27, or 31 batteries.

Please see options list and accessories page to specify components and other products you may need

Multilink Broadband Network Powering Products For Outside Plant 71

MULTILINK POWER SOURCE CATALOG.iSec1:71 Sec1:71 6/6/2007 12:46:43 PM


Standard MQ Enclosures - Standards
Part # 030-027-10 030-024-10 030-034-10 030-033-10 030-032-10 030-026-10 030-044-10 030-092-10
Model MQ-PS2-4 MQ-PS2-6 MQ-PS2-8 MQ-PS2-12 MQ-PSN-4 MQ-PSN-8 MQ-35-IS MQ-40
Main Application Power Supply Power Supply Power Supply Power Supply Power Supply, Power Supply, Power Supply Power Supply
& Battery & Battery & Battery & Battery Battery & Fiber Battery & Fiber & Battery & Battery
Enclosure Enclosure Enclosure Enclosure Node Enclosure Node Enclosure Enclosure Enclosure
Overall Dimensions 30.3”H x 30.3”H x 36”H x 36”W 36”H x 36”W 36”H x 36”W x 36”H x 36”W x 35”H x 36”W 40.7”H x
36”W x 23”D 36”W x 23”D x 25”D x 25”D 25”D 25”D x 23”D 42”W x 25”D
Internal Relay Rack
Power Supply Shelf X X X X X X X X
Battery Shelf X X X X X X X X
Life Saver Venting X X X X X X X X
Drop-In Doors X X X X X X X X
Ground Lug X X X X X X X X
Fastening Brackets X X
Internal Straps X X
Group 24 3 or 4 8 8 16 4 8 8 8
Group 27 or 31 3 or 4 6 6 16 4 8 6 6
AC Service External X X X X X X X
AC Service Internal X
Standard Features Legend: “X” Standard equipment or feature provided in enclosure

Standard MQ Enclosures - Options


Part # 030-027-10 030-024-10 030-034-10 030-033-10 030-032-10 030-026-10 030-044-10 030-092-10
Model MQ-PS2-4 MQ-PS2-6 MQ-PS2-8 MQ-PS2-12 MQ-PSN-4 MQ-PSN-8 MQ-35-IS MQ-40
Main Application Power Supply Power Supply Power Supply Power Supply Power Supply, Power Supply, Power Supply Power Supply
& Battery & Battery & Battery & Battery Battery & Fiber Battery & Fiber & Battery & Battery
Enclosure Enclosure Enclosure Enclosure Node Enclosure Node Enclosure Enclosure Enclosure
Overall Dimensions 30.3”H x 30.3”H x 36”H x 36”W 36”H x 36”W 36”H x 36”W x 36”H x 36”W x 35”H x 36”W 40.7”H x
36”W x 23”D 36”W x 23”D x 25”D x 25”D 25”D 25”D x 23”D 42”W x 25”D
Enclosure Fan Cooling “EFC-1” 035-004-20 035-004-20 035-004-20 035-004-20 035-004-20 035-004-20 035-004-20 035-004-20
120V, 20A Standard “SQD-1” 035-001-10 035-001-10 035-001-10 035-001-10 035-001-10 035-001-10 035-001-10 035-001-10
120V, 20A Hi Inrush “SQD-1HM” 035-001-11 035-001-11 035-001-11 035-001-11 035-001-11 035-001-11 035-001-11 035-001-11
240V, 20A 1 Outlet “SQD-2” 035-002-10 035-002-10 035-002-10 035-002-10 035-002-10 035-002-10 035-002-10 035-002-10
240V, 20A Dual Outlet “SQD-3” 035-009-10 035-009-10 035-009-10 035-009-10 035-009-10 035-009-10 035-009-10 035-009-10
120V, 20A Duplex “DOK-1” 035-007-10 035-007-10 035-007-10 035-007-10 035-007-10 035-007-10 035-007-10 035-007-10
240V, 15A Duplex “DOK-2” 035-008-10 035-008-10 035-008-10 035-008-10 035-008-10 035-008-10 035-008-10 035-008-10
High Brightness “ELK-1” 035-003-10 035-003-10 035-003-10 035-003-10 035-003-10 035-003-10 035-003-10 035-003-10
Economy “ELK-E” 035-015-10 035-015-10 035-015-10 035-015-10 035-015-10 035-015-10 035-015-10 035-015-10
Single Light “SIL-E” 035-036-20 035-036-20 035-036-20 035-036-20 035-036-20 035-036-20 035-036-20 035-036-20
Economy “PIM-E” 740-015-20 740-015-20 740-015-20 740-015-20 740-015-20 740-015-20 740-015-20 740-015-20
Standard “PIM-G” 740-009-20 740-009-20 740-009-20 740-009-20 740-009-20 740-009-20 740-009-20 740-009-20
Filtered “PIM-F” 740-011-20 740-011-20 740-011-20 740-011-20 740-011-20 740-011-20 740-011-20 740-011-20
3-battery 30 Amp “BWK-3” 874-001-20 n/a n/a n/a n/a n/a n/a n/a
3-battery 50 Amp “BWK-3HD” 874-001-21 n/a n/a n/a n/a n/a n/a n/a
4-battery 30 Amp “BWK-4” 874-002-20 n/a n/a 874-002-20 874-002-20 n/a n/a n/a
6-battery 30 Amp “BWK-6” n/a 874-003-20 874-003-20 n/a n/a n/a 874-003-20 874-003-20
6-battery 50 Amp “BWK-6HD” n/a 874-003-21 874-003-21 n/a n/a n/a 874-003-21 874-003-21
8-battery 30 Amp “BWK-8” n/a 874-004-20 874-004-20 n/a n/a 874-004-20 874-004-20 874-004-20
12-battery 30 Amp n/a n/a n/a n/a n/a n/a n/a n/a
12-battery 30A Fused n/a n/a n/a n/a n/a n/a n/a n/a
Standard Features Legend: “X” Standard equipment or feature provided in enclosure

72 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:72 Sec1:72 6/6/2007 12:46:46 PM


. MQ SERIES CABINETS LOW PROFILE.
Custom MQ Enclosures - Standards
Part # 030-053-10 030-031-10 030-075-10
Model MQ-PS1-G MQ-FRM MQ-FRM
Main Application Generator Storage Fiber Rack Mount Enclosure Fiber Rack Mount Enclosure
Overall Dimensions 36.16”H x 36”W x 23”D 36”H x 36”W x 25”D 36”H x 36”W x 25”D
Internal Relay Rack - 10-32 rails 12-24 rails
Power Supply Shelf - - -
Battery Shelf - - -
Life Saver Venting X - -
Drop-In Doors X - -
Ground Lug X X X
Fastening Brackets - - -
Internal Straps - - -
Group 24 - - -
Group 27 or 31 - - -
AC Service External - - -
AC Service Internal - - -
Standard Features Legend: “X” Standard equipment or feature provided in enclosure

Custom MQ Enclosures - Options


Part # 030-053-10 030-031-10 030-075-10
Model MQ-PS1-G MQ-FRM MQ-FRM
Main Application Generator Storage Fiber Rack Mount Enclosure Fiber Rack Mount Enclosure
Overall Dimensions 36.16”H x 36”W x 23”D 36”H x 36”W x 25”D 36”H x 36”W x 25”D
Enclosure Fan Cooling 035-004-20 “EFC-1” 035-004-20 “EFC-1” 035-004-20 “EFC-1”
120V, 20A Standard n/a 035-001-10 “SQD-1” 035-001-10 “SQD-1”
120V, 20A Hi Inrush n/a 035-001-11 “SQD-1HM” 035-001-11 “SQD-1HM”
240V, 20A 1 Outlet n/a 035-002-10 “SQD-2” 035-002-10 “SQD-2”
240V, 20A Dual Outlet n/a 035-009-10 “SQD-3” 035-009-10 “SQD-3”
120V, 20A Duplex n/a 035-007-10 “DOK-1” 035-007-10 “DOK-1”
240V, 15A Duplex n/a 035-008-10 “DOK-2” 035-008-10 “DOK-2”
High Brightness n/a 035-003-10 “ELK-1” 035-003-10 “ELK-1”
Economy n/a 035-015-10 “ELK-E” 035-015-10 “ELK-E”
Single Light n/a 035-036-20 “SIL-E” 035-036-20 “SIL-E”

Multilink Broadband Network Powering Products For Outside Plant 73

MULTILINK POWER SOURCE CATALOG.iSec1:73 Sec1:73 6/6/2007 12:46:47 PM


Pedestals 36”
Part # Description UOM
744-173-P1 MQ30-PED36 Raises enclosure to a height of 36” Each
- MQ36-PED36 Raises enclosure to a height of 36” Each

Pedestals 48”
Part # Description UOM
744-172-P1 MQ30-PED48 Raises enclosure to a height of 48” Each
744-170-P1 MQ36-PED48 Raises enclosure to a height of 48” Each

Cable Riser Kit


Part # Description UOM
035-020-10 MQ-CRK-30 Each
035-019-10 MQ-CRK-36 Each

Part # Description UOM


- MQ-BT-4 Each
- MQ-BT-6/8 Each

74 Multilink Broadband Network Powering Products For Outside Plant

MULTILINK POWER SOURCE CATALOG.iSec1:74 Sec1:74 6/6/2007 12:46:48 PM


. OTHER CATALOGS.

Multilink Broadband Network Powering Products For Outside Plant 75

MULTILINK POWER SOURCE CATALOG.iSec1:75 Sec1:75 6/6/2007 12:46:49 PM

Das könnte Ihnen auch gefallen