Resi9 The complete residential circuit protection offer Contents Introduction Resi9 Consumer Units ...................................................................................................................... p.4. Features & benefits ............................................................................................................................ p.5. Resi9 overview ....................................................................................................................................... p.6. Resi9 overview diagram ................................................................................................................... p.8. Product information Resi9........................................................................................................................................................... p10. Switch-disconnector ..........................................................................................................................p.11. RCCB Residual Current Circuit Breaker ..................................................................................p.12. RCBO Residual Current Device ...................................................................................................p.13. Circuit Breaker ..................................................................................................................................... p.14. Terminal Block ......................................................................................................................................p.15. Quick Selector Select consumer unit ....................................................................................................................... p.17. Select devices .......................................................................................................................................p.18. Technical Guide Resi9 - insulated unit dimensions ........................................................................................... p.20. Resi9 - metal unit dimensions .................................................................................................... p.21. 3 Resi9 consumer units The Resi9 range of consumer units provides arguably the highest levels of residential circuit protection safety. With a wide range of switch disconnectors, RCDs and MCBs, complimented by a single pole RCBO. Providing speed of installation with safety in mind. All outgoing devices can be connected in seconds and with no incoming terminal to tighten, the correct mechanical connection force is guaranteed every time. For unused ways, Resi9s unique fully encapsulated busbar system means that the highest levels of installer and end user protection are always guaranteed. Even with the front cover of the enclosure removed, the main busbar is protected to IP2X, meaning it remains nger safe but allows access with test probes by the installer. For energy management and safety, Resi9 can also accept a wide range of control devices. What really sets Resi9 apart is the plug-on breaker concept and fully encapsulated busbars. 4
Features and benefits Unique MCB/RCBO xing system. Provides complete nger safety to IP2XB, bringing increased levels of safety to consumer unit design Tested in accordance with BS EN 61439-3 Unrestricted cable entry can be made from any side Totally encapsulated busbar system Incoming devices can be ordered separately giving over a multitude of combinations from just 28 references Type A single pole RCBO Increased levels of user safety with Class II device front faces Retains plug-on philosophy for speed of installation and guaranteed connections Insulated safety pull up shuttered terminals limit incorrect cable insertion Control devices may be installed on any outgoing way No extra mounting accessories required Lockable cover option also available on metal units High temperature rated insulated enclosures 5 High temperature insulated consumer units
Totally encapsulated busbar system provides complete nger safety to IP2XB
Option 3 Incoming switch disconnector supplying two RCD protected sections Option 2 Split load consumer unit using RCBOs
Option 4 Incoming switch disconnector with RCBO ways and two RCD protected sections 7 Insulated, safety pull up shuttered terminals Finger touch proof terminals (FTPT) Class II Front face Guaranteed plug-on connections Clear and visible product information whatever the toggle position Resi9 The complete solution 8 Unique plug on system Type A RCBO devices Quick and easy to install 50% less connections to torque test Guaranteed compliance to standards 9 Resi9 The complete residential circuit protection offer 10 Compliance with standards BS EN 60947-3-1 Type Width Operating voltage Rating Cat. no. 9 mm module (V AC) (A) 2P 4 400 100 R9S87291 1 2 3 4 Degree of pollution: 2. Degree of protection (BS EN 60529): IP20B. Connection: > copper cable: - rigid: Max. 50 mm - exible: Max. 35 mm. > tightening torque: 3.5 N.m. Switch-disconnector To ensure: > control and disconnection of loaded electrical circuits. It must be protected: - against short circuits occurring downstream - against overloads; its rating must be at least equal to the rating of the upstream circuit breaker. ON/OFF Switch-disconnector 11 Type AC Width Operating voltage Sensitivity Rating Cat. no. 9 mm module (V AC) (mA) (A) 2P 4 230 30 63 R9R81263 30 100 R9R81291 300TD 100 R9R85291 Degree of pollution: 2. Degree of protection (BS EN 60529): IP20B. Connection: > Copper cable: - rigid: Max. 35 mm - exible: Max. 25 mm. > tightening torque: 3.5 N.m. Compliance with standards BS EN 61008-1 Residual current circuit breakers High sensitivity (30 mA) Protection against electric shocks by direct contact. Use at the incoming end of several feeders: > recommended for all power sockets. > compulsory for all equipment in bathrooms, outdoors, etc. Medium sensitivity (300mA) TD Protection against: > re following an insulation fault. > electric shocks by indirect contact. > in the event of tripping of a high-sensitivity residual current protection device downstream, maintains power for the other circuits. Use in residential units at the incoming end of the main switchboard. RCCB residual current circuit breaker 12 Compliance with standards BS EN 61009-1 Type A Width Operating voltage Sensitivity Rating Cat. no. 9 mm module (V AC) (mA) (A) B curve 1P+N 2 230 30 6 R9D87806 10 R9D87810 16 R9D87816 20 R9D87820 32 R9D87832 40 R9D87840* 50 R9D87850 Class Type A Breaking capacity: 6000 A. Degree of pollution: 2. Degree of protection (BS EN 60529): IP20B. Connection: > copper cable: - rigid: Max. 25 mm - exible: Max. 16 mm. > tightening torque: 2 N.m. Residual current devices Protection against: > cable overloads. > short circuits. > electric shocks by direct contact. Use in place of a circuit breaker, for circuits requiring protection against direct contacts: > recommended for all power sockets. > compulsory for all equipment in bathrooms, outdoors, etc. RCBO Residual current device * Available from July 2014 RCCB residual current circuit breaker L in N out L out N in I FE 13 Type Width Operating voltage Rating Cat. no. 9 mm module (V AC) (A) B curve C curve 1P 2 230 3 R9F87103 R9F64103 1 2 6 R9F87106 R9F64106 10 R9F87110 R9F64110 16 R9F87116 R9F64116 20 R9F87120 R9F64120 25 R9F87125 R9F64125 32 R9F87132 R9F64132 40 R9F87140 R9F64140 50 R9F87150 R9F64150 63 R9F87163 R9F64163 Compliance with standards BS EN 60898-1 - Breaking capacity: 6000 A. - Degree of pollution: 2. - Degree of protection (BS EN 60529): IP20B. - Type C MCBs denoted by grey appearance - Connection: - > copper cable: - - rigid: 25 A: Max. 25 mm2, 32 A: Max. 35 mm2 - - exible: 25 A: Max. 16 mm2, 32 A: Max. 25 mm2. - > tightening torque: - - 25 A: 2 N.m. - - 32 A: 3.5 N.m. Circuit breakers Protection against: > cable overloads. > short circuits. Circuit breaker 14 Compliance with standards BS EN 60998-1 Terminal block > Distribution and sub-distribution of the electric power supply. Terminal block Terminal block Width Cat. no. 2P 125 A 36 mm SE125L2 Degree of protection (BS EN 60529): IP20B. Terminal block 15 Quick selector Quick selector 16 Select Consumer Unit Insulated boards Standard Smoked Front No Of Ways
Note: Incoming and outgoing devices must be selected separately from the Resi9 devices section. The following refs are supplied with switch disconnector and RCDs fitted:- R9BSR6R6, R9BS2R5R5, R9BDS2R5R5
Note: Incoming and outgoing devices must be selected separately from the Resi9 devices section. The following refs are supplied with switch disconnector and RCDs fitted:- R9BMSR6R6, R9BMDS2R5R5, R9BMS2R5R5
17 Control devices May be installed at any outgoing point on the RCD protected or unprotected side
R9F87103 Single Pole 3A Type B MCB 6kA R9F64103 Single Pole 3A Type C MCB 6kA R9F87106 Single Pole 6A Type B MCB 6kA R9F64106 Single Pole 6A Type C MCB 6kA R9F87110 Single Pole 10A Type B MCB 6kA R9F64110 Single Pole 10A Type C MCB 6kA R9F87116 Single Pole 16A Type B MCB 6kA R9F64116 Single Pole 16A Type C MCB 6kA R9F87120 Single Pole 20A Type B MCB 6kA R9F64120 Single Pole 20A Type C MCB 6kA R9F87125 Single Pole 25A Type B MCB 6kA R9F64125 Single Pole 25A Type C MCB 6kA R9F87132 Single Pole 32A Type B MCB 6kA R9F64132 Single Pole 32A Type C MCB 6kA R9F87140 Single Pole 40A Type B MCB 6kA R9F64140 Single Pole 40A Type C MCB 6kA R9F87150 Single Pole 50A Type B MCB 6kA R9F64150 Single Pole 50A Type C MCB 6kA R9F87163 Single Pole 63A Type B MCB 6kA R9F64163 Single Pole 63A Type C MCB 6kA
RCBOs - Type A
R9D87806 Single Pole 6A/30mA B Curve RCBO R9D87810 Single Pole 10A/30mA B Curve RCBO R9D87816 Single Pole 16A/30mA B Curve RCBO R9D87820 Single Pole 20A/30mA B Curve RCBO R9D87825 Single Pole 25A/30mA B Curve RCBO R9D87832 Single Pole 32A/30mA B Curve RCBO R9D87840 Single Pole 40A/30mA B Curve RCBO R9D87850 Single Pole 50A/30mA B Curve RCBO
Control devices and accessories A9C20732 ICT 25A 2NO 230...240VAC 50HZ Contactor A9C20834 ICT 25A 4NO 220...240VAC 50HZ Contactor A9C20842 ICT 40A 2NO 220...240VAC 50HZ Contactor A9C20843 ICT 40A 3NO 220...240VAC 50HZ Contactor A9C20844 ICT 40A 4NO 220...240VAC 50HZ Contactor A9C20863 ICT 63A 3NO 220...240VAC 50HZ Contactor A9C30811 ITL16A 1NO 230/240VAC 110VDC 50-60 A9C30812 ITL16A 2NO 230/240VAC 50-60HZ 110V A9E15535 CHANGEOVER RELAY IRLI 10A 2P UC 230V-240 A9A15321 ISO BELL 8 12V A9A15214 BELL TRANSFORMER 4VA 230VCA 8VCA A9A15323 BUZZER 8..12 VCA 70DBA 50..60HZ CCT15368 IC2000 light sensitive switch 15336 24HR analogue time switch with reserve CCT15720 1 Channel IHP program time switch CCT15722 2 Channel IHP program time switch 15363 MIN time switch 1-7mins (delayed off) A9A27062 5X SPACER 9MM IC60 IID ICT SEPLMCB MCB Padlock attachment (pk10) MCB SEPLRCBO RCBO Padlock attachment (pk10) RCBO SEPL Padlock (can be used with MCB or RCBO attachment) EZ9LKIT Door lock kit (metal enclosure) SEDNBP Blanking plate 5 module 18 Select devices Incoming Devices
R9F87103 Single Pole 3A Type B MCB 6kA R9F64103 Single Pole 3A Type C MCB 6kA R9F87106 Single Pole 6A Type B MCB 6kA R9F64106 Single Pole 6A Type C MCB 6kA R9F87110 Single Pole 10A Type B MCB 6kA R9F64110 Single Pole 10A Type C MCB 6kA R9F87116 Single Pole 16A Type B MCB 6kA R9F64116 Single Pole 16A Type C MCB 6kA R9F87120 Single Pole 20A Type B MCB 6kA R9F64120 Single Pole 20A Type C MCB 6kA R9F87125 Single Pole 25A Type B MCB 6kA R9F64125 Single Pole 25A Type C MCB 6kA R9F87132 Single Pole 32A Type B MCB 6kA R9F64132 Single Pole 32A Type C MCB 6kA R9F87140 Single Pole 40A Type B MCB 6kA R9F64140 Single Pole 40A Type C MCB 6kA R9F87150 Single Pole 50A Type B MCB 6kA R9F64150 Single Pole 50A Type C MCB 6kA R9F87163 Single Pole 63A Type B MCB 6kA R9F64163 Single Pole 63A Type C MCB 6kA
RCBOs - Type A
R9D87806 Single Pole 6A/30mA B Curve RCBO R9D87810 Single Pole 10A/30mA B Curve RCBO R9D87816 Single Pole 16A/30mA B Curve RCBO R9D87820 Single Pole 20A/30mA B Curve RCBO R9D87825 Single Pole 25A/30mA B Curve RCBO R9D87832 Single Pole 32A/30mA B Curve RCBO R9D87840 Single Pole 40A/30mA B Curve RCBO R9D87850 Single Pole 50A/30mA B Curve RCBO
Control devices and accessories A9C20732 ICT 25A 2NO 230...240VAC 50HZ Contactor A9C20834 ICT 25A 4NO 220...240VAC 50HZ Contactor A9C20842 ICT 40A 2NO 220...240VAC 50HZ Contactor A9C20843 ICT 40A 3NO 220...240VAC 50HZ Contactor A9C20844 ICT 40A 4NO 220...240VAC 50HZ Contactor A9C20863 ICT 63A 3NO 220...240VAC 50HZ Contactor A9C30811 ITL16A 1NO 230/240VAC 110VDC 50-60 A9C30812 ITL16A 2NO 230/240VAC 50-60HZ 110V A9E15535 CHANGEOVER RELAY IRLI 10A 2P UC 230V-240 A9A15321 ISO BELL 8 12V A9A15214 BELL TRANSFORMER 4VA 230VCA 8VCA A9A15323 BUZZER 8..12 VCA 70DBA 50..60HZ CCT15368 IC2000 light sensitive switch 15336 24HR analogue time switch with reserve CCT15720 1 Channel IHP program time switch CCT15722 2 Channel IHP program time switch 15363 MIN time switch 1-7mins (delayed off) A9A27062 5X SPACER 9MM IC60 IID ICT SEPLMCB MCB Padlock attachment (pk10) MCB SEPLRCBO RCBO Padlock attachment (pk10) RCBO SEPL Padlock (can be used with MCB or RCBO attachment) EZ9LKIT Door lock kit (metal enclosure) SEDNBP Blanking plate 5 module Technical guide Technical guide 19 3 8 6 5 42 M I M I L or N J or K B 24 240 E H H E 127 116 G F A E D E F G Cable Access Points in Cover Technical data Metal Insulated Max. busbar current rating (A) 100 100 Max. operating voltage (V) 240 240 Operating frequency (Hz) 50 50 Max. incoming cable capacity mm2 (phase and neutral) 50 50 Max. outgoing cable capacity mm2 25 25 Certification BS EN 61439-3 BS EN 61439-3 IP rating BS EN 60529 (internal) 2XB 2XB Resi9 - insulated unit dimensions
Insulated units Reference number No. of ways Type Dimensions (mm)
A B R9B02 2 Standard 189 126 R9B04 4 Standard 224 162 R9B06 R9B06SG 6 Standard 260 198 R9B08 R9B08SG 8 Standard 296 234 R9B012 R9B012SG 12 Standard 368 306 R9B016 16 Standard 440 378 R9B023 24 Standard 368 306 R9BS5R5 5+5 Split 368 306 R9BS6R4 6+4 Split 368 306 R9BS7R7 7+7 Split 440 378 R9BSR6R6 R9BSR6R6SG 6+6 Split 440 378 R9BS2R5R5 R9BS2R5R5SG 2+5+5 Multiple 440 378 R9BDS2R5R5 R9BDS2R5R5SG 2+5+5 Multiple 440 378 No. of knockouts Type D E F G H I J K L M N 2 way 6 4 6 2 2 2 2 4 way 6 4 8 4 4 6 way 2 8 4 4 6 6 8 way 2 4 4 4 4 6 2 2 6 12 way 4 6 2 4 4 10 10 16 way 6 4 4 4 4 10 2 10 2 Note: 24 way unit is made up of 2, stacked, 12 way enclosures and are supplied complete with connection kit. Incoming and outgoing devices must be selected separately from the Resi9 devices section. The following refs are supplied with switch disconnector and RCDs fitted:- R9BSR6R6, R9BS2R5R5, R9BDS2R5R5 Cable entry sizes (mm) D 23 x 51 E 15 x 38 F 15 x 51 G 13 x 16 H 15 x 25 I 25 x 48 J 25 x 30 K 25 x 65 L 13 x 30 M 13 x 48 N 13 x 68 Height 240mm Depth 127mm
20 Resi9 - metal unit dimensions Metal units Dimensions (mm) No. of knockouts Reference number No. of ways Type A B D E F G H 25 x 89 30mm 25mm 20mm R9BM2 2 Standard 181 119 2 2 8 R9BM4 4 Standard 222 155 2 2 2 8 R9BM6 R9BM6SG 6 Standard 258 191 2 4 8 R9BM8 R9BM8SG 8 Standard 294 227 2 4 10 2 R9BM12 R9BM12SG 12 Standard 366 299 4 4 4 12 R9BM16 16 Standard 438 371 4 4 4 16 R9BM24 24 Standard 366 299 6 4 4 8 R9BMS4R6 4+6 Split 378 299 4 4 4 12 R9BMS5R5 5+5 Split 378 299 4 4 4 12 R9BMS6R4 6+4 Split 378 299 4 4 4 12 R9BMS7R7 7+7 Split 450 371 4 4 4 16 R9BMSR6R6 R9BMSR6R6SG 6+6 Multiple 450 371 4 4 4 16 R9BMDS2R5R5 R9BMDS2R5R5SG 2+5+5 Multiple 450 371 4 4 4 16 R9BMS2R5R5 R9BMS2R5R5SG 2+5+5 Multiple 450 371 4 4 4 16
Note: Rear of enclosure = 242mm high Incoming and outgoing devices must be selected separately from the Resi9 devices section. The following refs are supplied with switch disconnector and RCDs fitted:- R9BMSR6R6, R9BMDS2R5R5, R9BMS2R5R5
Cable entry sizes (mm) 116 39 27 247 (surface) 259 (flush) 111 86 (all dimensions in mm) 44 54 27 43 12 & 16 Way only 4 to 16 Way only 6 to 16 Way only 27 G G G G G G E E F F 2 WAY ONLY 54 61 180 Dotted line indicates cover D F H D D F H D 63 5.5 9.5 5.5 73 31 B A Technical data Metal Insulated Max. busbar current rating (A) 100 100 Max. operating voltage (V) 240 240 Operating frequency (Hz) 50 50 Max. incoming cable capacity mm2 (phase and neutral) 50 50 Max. outgoing cable capacity mm2 25 25 Certification BS EN 61439-3 BS EN 61439-3 IP rating BS EN 60529 (internal) 2XB 2XB Height 247mm Depth 111mm 21 RSD unit mounted RCCBs and insulated enclosures
Unit mounted RCCBs and their associated enclosures offer a cost effective method of supplementing existing installations with the benefits of earth fault protection. Enclosures may be mounted at the incoming point of the installation or locally to the load eg, in garages or sheds with socket outlets.
Test button enables RCCB to be tested periodically
Comply with BS EN 61008. Specification for residual current operated circuit breakers
Rated voltage 240Vac single phase For short circuit back-up protection, maximum fuse rating:-
Residual current breakers Reference number Description Cable capacity Dimensions Weight
Individual RCCB insulated enclosures Reference number Description Dimensions (mm) Weight Height Width Depth kg 13392 2 x 18mm module IP40 protection 150 50 60 0.1 RSD4IP54 4 x 18mm module IP54 protection 200 110 112 0.35
A cost effective method of providing earth fault protection for existing single circuits or entire installations Providing speed of installation with safety in mind. 22 23 UK contact details - 0870 608 8 608 Fax 0870 608 8 606 Ireland contact details - 01 601 2200 Fax 01 601 2201 As the global specialist in energy management with operations in more than 100 countries, Schneider Electric offers integrated solutions across multiple market segments, including leadership positions in energy and infrastructure, industrial processes, building automation, and data centres/ networks, as well as a broad presence in residential applications. Schneider Electric is dedicated to making individuals and organisations energy safe, reliable, efficient, productive and green from Power Plant to Plug TM . We are changing our brand names and becoming one Schneider Electric. Youll get the same great quality products, but from one name you can remember and trust. This provides you and your customers with the reassurance associated with Schneider Electric. Some of our market leading brands have already become Schneider Electric including Merlin Gerin, Telemecanique, Square D, GET, Mita, Sarel, Himel, Thorsman, Tower and TAC. Working as one Schneider Electric makes it clearer that our ranges are highly compatible for integrated solutions. Schneider Electric Ltd Schneider Electric Limited is a company registered in England and Wales. Registered number: 1407228. Registered ofce: Stafford Park 5, Telford, Shropshire TF3 3BL. 2014 Schneider Electric. All Rights Reserved. Schneider Electric, Active Energy Management, Compact, EcoStruxure, ION Enterprise, iRIO, Make the most of your energy, Masterpact, Micrologic, Power Plant To Plug, Modbus, and PowerLogic are owned by Schneider Electric Industries SAS, or its afliated companies in the United States and other countries. As standards, specications and designs change from time to time, please ask for conrmation of the information given in this publication. S E 8 3 2 5
J A N
2 0 1 4 United Kingdom Stafford Park 5, Telford Shropshire TF3 3BL Tel: 0870 608 8 608 Fax: 0870 608 8 606 www.schneider-electric.com/uk Ireland Head ofce, Block a Maynooth Business Campus Maynooth, Co. Kildare Tel: (01) 601 2200 Fax: (01) 601 2201 www.schneider-electric.com/ie member of