Resi9

The complete residential


circuit protection offer
2

Resi9
The complete residential
circuit protection offer
Contents
Introduction
Resi9 Consumer Units ...................................................................................................................... p.4.
Features & benefits ............................................................................................................................ p.5.
Resi9 overview ....................................................................................................................................... p.6.
Resi9 overview diagram ................................................................................................................... p.8.
Product information
Resi9........................................................................................................................................................... p10.
Switch-disconnector ..........................................................................................................................p.11.
RCCB Residual Current Circuit Breaker ..................................................................................p.12.
RCBO Residual Current Device ...................................................................................................p.13.
Circuit Breaker ..................................................................................................................................... p.14.
Terminal Block ......................................................................................................................................p.15.
Quick Selector
Select consumer unit ....................................................................................................................... p.17.
Select devices .......................................................................................................................................p.18.
Technical Guide
Resi9 - insulated unit dimensions ........................................................................................... p.20.
Resi9 - metal unit dimensions .................................................................................................... p.21.
3
Resi9 consumer units
The Resi9 range of consumer units provides arguably the highest levels of residential
circuit protection safety. With a wide range of switch disconnectors, RCDs and MCBs,
complimented by a single pole RCBO.
Providing speed of installation with safety in mind.
All outgoing devices can be connected in seconds and with no incoming terminal to
tighten, the correct mechanical connection force is guaranteed every time. For unused
ways, Resi9s unique fully encapsulated busbar system means that the highest levels of
installer and end user protection are always guaranteed.
Even with the front cover of the enclosure removed, the main busbar is protected to IP2X,
meaning it remains nger safe but allows access with test probes by the installer. For
energy management and safety, Resi9 can also accept a wide range of control devices.
What really sets Resi9 apart is the plug-on breaker concept
and fully encapsulated busbars.
4

Features and benefits
Unique MCB/RCBO xing system.
Provides complete nger safety to IP2XB, bringing
increased levels of safety to consumer unit design
Tested in accordance with BS EN 61439-3
Unrestricted cable entry can be made from any side
Totally encapsulated busbar system
Incoming devices can be ordered separately giving over
a multitude of combinations from just 28 references
Type A single pole RCBO
Increased levels of user safety with Class II device front
faces
Retains plug-on philosophy for speed of installation and
guaranteed connections
Insulated safety pull up shuttered terminals limit incorrect
cable insertion
Control devices may be installed on any outgoing way
No extra mounting accessories required
Lockable cover option also available on metal units
High temperature rated insulated enclosures
5
High temperature insulated consumer units

Totally encapsulated busbar system provides
complete nger safety to IP2XB

White or smoked front covers as standard

Unrestricted cable entry from any side

Metal enclosures

Lockable option available on metal units

Resi9
Overview
6
Option 1
Incoming switch disconnector and outgoing
RCBOs

Option 3
Incoming switch disconnector supplying two
RCD protected sections
Option 2
Split load consumer unit using RCBOs

Option 4
Incoming switch disconnector with RCBO
ways and two RCD protected sections
7
Insulated, safety pull up shuttered
terminals
Finger touch proof terminals (FTPT)
Class II Front face
Guaranteed plug-on connections
Clear and visible product information
whatever the toggle position
Resi9
The complete solution
8
Unique plug on system
Type A RCBO devices
Quick and easy to install
50% less connections to torque test
Guaranteed compliance to standards
9
Resi9
The complete residential circuit protection offer
10
Compliance with standards BS EN 60947-3-1
Type Width Operating
voltage
Rating Cat. no.
9 mm
module
(V AC) (A)
2P 4 400 100 R9S87291
1
2
3
4
Degree of pollution: 2.
Degree of protection (BS EN 60529): IP20B.
Connection:
> copper cable:
- rigid: Max. 50 mm
- exible: Max. 35 mm.
> tightening torque: 3.5 N.m.
Switch-disconnector
To ensure:
> control and disconnection of loaded electrical circuits.
It must be protected:
- against short circuits occurring downstream
- against overloads; its rating must be at least equal to the rating of the upstream
circuit breaker.
ON/OFF
Switch-disconnector
11
Type AC Width Operating
voltage
Sensitivity Rating Cat. no.
9 mm
module
(V AC) (mA) (A)
2P 4 230 30 63 R9R81263
30 100 R9R81291
300TD 100 R9R85291
Degree of pollution: 2.
Degree of protection (BS EN 60529): IP20B.
Connection:
> Copper cable:
- rigid: Max. 35 mm
- exible: Max. 25 mm.
> tightening torque: 3.5 N.m.
Compliance with
standards
BS EN 61008-1
Residual current circuit breakers
High sensitivity (30 mA)
Protection against electric shocks by direct contact.
Use at the incoming end of several feeders:
> recommended for all power sockets.
> compulsory for all equipment in bathrooms, outdoors, etc.
Medium sensitivity (300mA) TD
Protection against:
> re following an insulation fault.
> electric shocks by indirect contact.
> in the event of tripping of a high-sensitivity residual current protection device
downstream, maintains power for the other circuits.
Use in residential units at the incoming end of the main switchboard.
RCCB residual current circuit breaker
12
Compliance with
standards
BS EN 61009-1
Type A Width Operating
voltage
Sensitivity Rating Cat. no.
9 mm
module
(V AC) (mA) (A) B curve
1P+N 2 230 30 6 R9D87806
10 R9D87810
16 R9D87816
20 R9D87820
32 R9D87832
40 R9D87840*
50 R9D87850
Class Type A
Breaking capacity: 6000 A.
Degree of pollution: 2.
Degree of protection (BS EN 60529): IP20B.
Connection:
> copper cable:
- rigid: Max. 25 mm
- exible: Max. 16 mm.
> tightening torque: 2 N.m.
Residual current devices
Protection against:
> cable overloads.
> short circuits.
> electric shocks by direct contact.
Use in place of a circuit breaker, for circuits requiring protection against direct contacts:
> recommended for all power sockets.
> compulsory for all equipment in bathrooms, outdoors, etc.
RCBO Residual current device
* Available from July 2014
RCCB residual current circuit breaker
L in
N out L out
N in
I
FE
13
Type Width Operating
voltage
Rating Cat. no.
9 mm
module
(V AC) (A) B curve C curve
1P 2 230 3 R9F87103 R9F64103
1
2
6 R9F87106 R9F64106
10 R9F87110 R9F64110
16 R9F87116 R9F64116
20 R9F87120 R9F64120
25 R9F87125 R9F64125
32 R9F87132 R9F64132
40 R9F87140 R9F64140
50 R9F87150 R9F64150
63 R9F87163 R9F64163
Compliance with
standards
BS EN 60898-1
- Breaking capacity: 6000 A.
- Degree of pollution: 2.
- Degree of protection (BS EN 60529): IP20B.
- Type C MCBs denoted by grey appearance
- Connection:
- > copper cable:
- - rigid: 25 A: Max. 25 mm2, 32 A: Max. 35 mm2
- - exible: 25 A: Max. 16 mm2, 32 A: Max. 25 mm2.
- > tightening torque:
- - 25 A: 2 N.m.
- - 32 A: 3.5 N.m.
Circuit breakers
Protection against:
> cable overloads.
> short circuits.
Circuit breaker
14
Compliance with
standards
BS EN 60998-1
Terminal block
> Distribution and sub-distribution of the electric power
supply.
Terminal block
Terminal block Width Cat. no.
2P
125 A 36 mm SE125L2
Degree of protection (BS EN 60529): IP20B.
Terminal block
15
Quick selector
Quick selector
16
Select Consumer Unit
Insulated boards
Standard Smoked Front No Of Ways

R9B02 2
R9B04 4
R9B06 R9B06SG 6
R9B08 R9B08SG 8
R9B012 R9B012SG 12
R9B016 16
R9B023 24



Split Load - Insulated Total Ways SW Ways RCD Ways

R9BS5R5 10 5 5
R9BS6R4 10 6 4
R9BS7R7 14 7 7
Insulated multiple split busbar - supplied with switch disconnectors and RCDs
Standard Smoked Front Total Ways Sw Ways RCD 1 Ways RCD 2 Ways

R9BSR6R6 R9BSR6R6SG 12 - 6 (63A) 6 (63A)
R9BDS2R5R5 R9BDS2R5R5SG 12 2 5 (100A) 5 (100A)
R9BS2R5R5 R9BS2R5R5SG 12 2 5 (63A) 5 (63A)

Note: Incoming and outgoing devices must be selected separately from the Resi9 devices section.
The following refs are supplied with switch disconnector and RCDs fitted:- R9BSR6R6, R9BS2R5R5, R9BDS2R5R5


Metal boards
standard Smoked Front No Of Ways

R9BM2 2
R9BM4 4
R9BM6 R9BM6SG 6
R9BM8 R9BM8SG 8
R9BM12 R9BM12SG 12
R9BM16 16
R9BM24 24

Split Load - Metal Total Ways SW Ways RCD Ways

R9BMS4R6 10 4 6
R9BMS5R5 10 5 5
R9BMS6R4 10 6 4
R9BMS7R7 14 7 7
Metal multiple split busbar - supplied with switch disconnectors and RCDs
Standard Smoked Front Total Ways Sw Ways RCD 1 Ways RCD 2 Ways

R9BMSR6R6 R9BMSR6R6SG 12 - 6 (63A) 6 (63A)
R9BMDS2R5R5 R9BMDS2R5R5SG 12 2 5 (100A) 5 (100A)
R9BMS2R5R5 R9BMS2R5R5SG 12 2 5 (63A) 5 (63A)

Note: Incoming and outgoing devices must be selected separately from the Resi9 devices section.
The following refs are supplied with switch disconnector and RCDs fitted:- R9BMSR6R6, R9BMDS2R5R5, R9BMS2R5R5

17
Control devices
May be installed at any outgoing point on the RCD protected or unprotected side

Select devices
Incoming Devices

R9R81263 63A/30mA RCCB
R9R81291 100A/30mA RCCB
R9R85291 100A/300mA RCCB TD
R9S87291 100A Switch Disconnector
SE125L2 100A Terminal Block

Outgoing Device
MCBs type B MCBs type C

R9F87103 Single Pole 3A Type B MCB 6kA R9F64103 Single Pole 3A Type C MCB 6kA
R9F87106 Single Pole 6A Type B MCB 6kA R9F64106 Single Pole 6A Type C MCB 6kA
R9F87110 Single Pole 10A Type B MCB 6kA R9F64110 Single Pole 10A Type C MCB 6kA
R9F87116 Single Pole 16A Type B MCB 6kA R9F64116 Single Pole 16A Type C MCB 6kA
R9F87120 Single Pole 20A Type B MCB 6kA R9F64120 Single Pole 20A Type C MCB 6kA
R9F87125 Single Pole 25A Type B MCB 6kA R9F64125 Single Pole 25A Type C MCB 6kA
R9F87132 Single Pole 32A Type B MCB 6kA R9F64132 Single Pole 32A Type C MCB 6kA
R9F87140 Single Pole 40A Type B MCB 6kA R9F64140 Single Pole 40A Type C MCB 6kA
R9F87150 Single Pole 50A Type B MCB 6kA R9F64150 Single Pole 50A Type C MCB 6kA
R9F87163 Single Pole 63A Type B MCB 6kA R9F64163 Single Pole 63A Type C MCB 6kA

RCBOs - Type A

R9D87806 Single Pole 6A/30mA B Curve RCBO
R9D87810 Single Pole 10A/30mA B Curve RCBO
R9D87816 Single Pole 16A/30mA B Curve RCBO
R9D87820 Single Pole 20A/30mA B Curve RCBO
R9D87825 Single Pole 25A/30mA B Curve RCBO
R9D87832 Single Pole 32A/30mA B Curve RCBO
R9D87840 Single Pole 40A/30mA B Curve RCBO
R9D87850 Single Pole 50A/30mA B Curve RCBO

Control devices and accessories
A9C20732 ICT 25A 2NO 230...240VAC 50HZ Contactor
A9C20834 ICT 25A 4NO 220...240VAC 50HZ Contactor
A9C20842 ICT 40A 2NO 220...240VAC 50HZ Contactor
A9C20843 ICT 40A 3NO 220...240VAC 50HZ Contactor
A9C20844 ICT 40A 4NO 220...240VAC 50HZ Contactor
A9C20863 ICT 63A 3NO 220...240VAC 50HZ Contactor
A9C30811 ITL16A 1NO 230/240VAC 110VDC 50-60
A9C30812 ITL16A 2NO 230/240VAC 50-60HZ 110V
A9E15535 CHANGEOVER RELAY IRLI 10A 2P UC 230V-240
A9A15321 ISO BELL 8 12V
A9A15214 BELL TRANSFORMER 4VA 230VCA 8VCA
A9A15323 BUZZER 8..12 VCA 70DBA 50..60HZ
CCT15368 IC2000 light sensitive switch
15336 24HR analogue time switch with reserve
CCT15720 1 Channel IHP program time switch
CCT15722 2 Channel IHP program time switch
15363 MIN time switch 1-7mins (delayed off)
A9A27062 5X SPACER 9MM IC60 IID ICT
SEPLMCB MCB Padlock attachment (pk10) MCB
SEPLRCBO RCBO Padlock attachment (pk10) RCBO
SEPL Padlock (can be used with MCB or RCBO attachment)
EZ9LKIT Door lock kit (metal enclosure)
SEDNBP Blanking plate 5 module
18
Select devices
Incoming Devices

R9R81263 63A/30mA RCCB
R9R81291 100A/30mA RCCB
R9R85291 100A/300mA RCCB TD
R9S87291 100A Switch Disconnector
SE125L2 100A Terminal Block

Outgoing Device
MCBs type B MCBs type C

R9F87103 Single Pole 3A Type B MCB 6kA R9F64103 Single Pole 3A Type C MCB 6kA
R9F87106 Single Pole 6A Type B MCB 6kA R9F64106 Single Pole 6A Type C MCB 6kA
R9F87110 Single Pole 10A Type B MCB 6kA R9F64110 Single Pole 10A Type C MCB 6kA
R9F87116 Single Pole 16A Type B MCB 6kA R9F64116 Single Pole 16A Type C MCB 6kA
R9F87120 Single Pole 20A Type B MCB 6kA R9F64120 Single Pole 20A Type C MCB 6kA
R9F87125 Single Pole 25A Type B MCB 6kA R9F64125 Single Pole 25A Type C MCB 6kA
R9F87132 Single Pole 32A Type B MCB 6kA R9F64132 Single Pole 32A Type C MCB 6kA
R9F87140 Single Pole 40A Type B MCB 6kA R9F64140 Single Pole 40A Type C MCB 6kA
R9F87150 Single Pole 50A Type B MCB 6kA R9F64150 Single Pole 50A Type C MCB 6kA
R9F87163 Single Pole 63A Type B MCB 6kA R9F64163 Single Pole 63A Type C MCB 6kA

RCBOs - Type A

R9D87806 Single Pole 6A/30mA B Curve RCBO
R9D87810 Single Pole 10A/30mA B Curve RCBO
R9D87816 Single Pole 16A/30mA B Curve RCBO
R9D87820 Single Pole 20A/30mA B Curve RCBO
R9D87825 Single Pole 25A/30mA B Curve RCBO
R9D87832 Single Pole 32A/30mA B Curve RCBO
R9D87840 Single Pole 40A/30mA B Curve RCBO
R9D87850 Single Pole 50A/30mA B Curve RCBO

Control devices and accessories
A9C20732 ICT 25A 2NO 230...240VAC 50HZ Contactor
A9C20834 ICT 25A 4NO 220...240VAC 50HZ Contactor
A9C20842 ICT 40A 2NO 220...240VAC 50HZ Contactor
A9C20843 ICT 40A 3NO 220...240VAC 50HZ Contactor
A9C20844 ICT 40A 4NO 220...240VAC 50HZ Contactor
A9C20863 ICT 63A 3NO 220...240VAC 50HZ Contactor
A9C30811 ITL16A 1NO 230/240VAC 110VDC 50-60
A9C30812 ITL16A 2NO 230/240VAC 50-60HZ 110V
A9E15535 CHANGEOVER RELAY IRLI 10A 2P UC 230V-240
A9A15321 ISO BELL 8 12V
A9A15214 BELL TRANSFORMER 4VA 230VCA 8VCA
A9A15323 BUZZER 8..12 VCA 70DBA 50..60HZ
CCT15368 IC2000 light sensitive switch
15336 24HR analogue time switch with reserve
CCT15720 1 Channel IHP program time switch
CCT15722 2 Channel IHP program time switch
15363 MIN time switch 1-7mins (delayed off)
A9A27062 5X SPACER 9MM IC60 IID ICT
SEPLMCB MCB Padlock attachment (pk10) MCB
SEPLRCBO RCBO Padlock attachment (pk10) RCBO
SEPL Padlock (can be used with MCB or RCBO attachment)
EZ9LKIT Door lock kit (metal enclosure)
SEDNBP Blanking plate 5 module
Technical guide
Technical guide
19
3
8
6
5
42 M I M I L or N J or K
B
24
240
E
H
H
E
127 116
G F
A
E D E F G
Cable Access Points in Cover
Technical data
Metal Insulated
Max. busbar current rating (A) 100 100
Max. operating voltage (V) 240 240
Operating frequency (Hz) 50 50
Max. incoming cable capacity mm2 (phase and neutral) 50 50
Max. outgoing cable capacity mm2 25 25
Certification BS EN 61439-3 BS EN 61439-3
IP rating BS EN 60529 (internal) 2XB 2XB
Resi9 - insulated unit dimensions

Insulated units
Reference number No. of ways Type Dimensions (mm)

A B
R9B02 2 Standard 189 126
R9B04 4 Standard 224 162
R9B06 R9B06SG 6 Standard 260 198
R9B08 R9B08SG 8 Standard 296 234
R9B012 R9B012SG 12 Standard 368 306
R9B016 16 Standard 440 378
R9B023 24 Standard 368 306
R9BS5R5 5+5 Split 368 306
R9BS6R4 6+4 Split 368 306
R9BS7R7 7+7 Split 440 378
R9BSR6R6 R9BSR6R6SG 6+6 Split 440 378
R9BS2R5R5 R9BS2R5R5SG 2+5+5 Multiple 440 378
R9BDS2R5R5 R9BDS2R5R5SG 2+5+5 Multiple 440 378
No. of knockouts
Type D E F G H I J K L M N
2 way 6 4 6 2 2 2 2
4 way 6 4 8 4 4
6 way 2 8 4 4 6 6
8 way 2 4 4 4 4 6 2 2 6
12 way 4 6 2 4 4 10 10
16 way 6 4 4 4 4 10 2 10 2
Note: 24 way unit is made up of 2, stacked, 12 way enclosures and are supplied complete with connection kit.
Incoming and outgoing devices must be selected separately from the Resi9 devices section.
The following refs are supplied with switch disconnector and RCDs fitted:- R9BSR6R6, R9BS2R5R5, R9BDS2R5R5
Cable entry sizes (mm)
D 23 x 51
E 15 x 38
F 15 x 51
G 13 x 16
H 15 x 25
I 25 x 48
J 25 x 30
K 25 x 65
L 13 x 30
M 13 x 48
N 13 x 68
Height 240mm
Depth 127mm

20
Resi9 - metal unit dimensions
Metal units Dimensions (mm) No. of knockouts
Reference number No. of ways Type A B D E F G H
25 x 89 30mm 25mm 20mm
R9BM2 2 Standard 181 119 2 2 8
R9BM4 4 Standard 222 155 2 2 2 8
R9BM6 R9BM6SG 6 Standard 258 191 2 4 8
R9BM8 R9BM8SG 8 Standard 294 227 2 4 10 2
R9BM12 R9BM12SG 12 Standard 366 299 4 4 4 12
R9BM16 16 Standard 438 371 4 4 4 16
R9BM24 24 Standard 366 299 6 4 4 8
R9BMS4R6 4+6 Split 378 299 4 4 4 12
R9BMS5R5 5+5 Split 378 299 4 4 4 12
R9BMS6R4 6+4 Split 378 299 4 4 4 12
R9BMS7R7 7+7 Split 450 371 4 4 4 16
R9BMSR6R6 R9BMSR6R6SG 6+6 Multiple 450 371 4 4 4 16
R9BMDS2R5R5 R9BMDS2R5R5SG 2+5+5 Multiple 450 371 4 4 4 16
R9BMS2R5R5 R9BMS2R5R5SG 2+5+5 Multiple 450 371 4 4 4 16

Note: Rear of enclosure = 242mm high
Incoming and outgoing devices must be selected separately from the Resi9 devices section.
The following refs are supplied with switch disconnector and RCDs fitted:- R9BMSR6R6, R9BMDS2R5R5, R9BMS2R5R5

Cable entry sizes (mm)
116
39
27
247 (surface)
259 (flush)
111
86
(all dimensions in mm)
44 54
27
43
12 & 16 Way only
4 to 16 Way only
6 to 16 Way only
27
G G G G G
G
E E
F F
2 WAY ONLY
54 61
180
Dotted line
indicates cover
D F
H
D
D F
H
D
63
5.5
9.5
5.5 73
31 B
A
Technical data
Metal Insulated
Max. busbar current rating (A) 100 100
Max. operating voltage (V) 240 240
Operating frequency (Hz) 50 50
Max. incoming cable capacity mm2 (phase and neutral) 50 50
Max. outgoing cable capacity mm2 25 25
Certification BS EN 61439-3 BS EN 61439-3
IP rating BS EN 60529 (internal) 2XB 2XB
Height 247mm
Depth 111mm
21
RSD unit mounted RCCBs and insulated enclosures

Unit mounted RCCBs and their associated enclosures offer a cost effective method of supplementing existing installations with the benefits
of earth fault protection.
Enclosures may be mounted at the incoming point of the installation or locally to the load eg, in garages or sheds with socket outlets.

Test button enables RCCB to be tested periodically

Comply with BS EN 61008. Specification for residual current operated circuit breakers

Rated voltage 240Vac single phase
For short circuit back-up protection, maximum fuse rating:-

Residual current breakers
Reference number Description Cable capacity Dimensions Weight

mm2 Height Width Depth kg
SED25032 25A RCCB 30mA trip 2 pole 35 81 36 75 0.227
SED25302 25A RCCB 300mA trip 2 pole 35 81 36 75 0.227
SED40032 40A RCCB 30mA trip 2 pole 35 81 36 75 0.227
SED40102 40A RCCB 100mA trip 2 pole 35 81 36 75 0.227
SED40302 40A RCCB 300mA trip 2 pole 35 81 36 75 0.227
SED63032 63A RCCB 30mA trip 2 pole 35 81 36 75 0.227
SED63102 63A RCCB 100mA trip 2 pole 35 81 36 75 0.227
SED63302 63A RCCB 300mA trip 2 pole 35 81 36 75 0.227
SED80032 80A RCCB 30mA trip 2 pole 50 81 36 75 0.227
SED100032 100A RCCB 30mA trip 2 pole 50 81 36 75 0.227
SED100102 100A RCCB 100mA trip 2 pole 50 81 36 75 0.227

Individual RCCB insulated enclosures
Reference number Description Dimensions (mm) Weight
Height Width Depth kg
13392 2 x 18mm module IP40 protection 150 50 60 0.1
RSD4IP54 4 x 18mm module IP54 protection 200 110 112 0.35

A cost effective method of providing
earth fault protection for existing single
circuits or entire installations
Providing speed of installation with safety in mind.
22
23
UK contact details -
0870 608 8 608
Fax 0870 608 8 606
Ireland contact details -
01 601 2200
Fax 01 601 2201
As the global specialist in energy management with operations in more
than 100 countries, Schneider Electric offers integrated solutions across
multiple market segments, including leadership positions in energy and
infrastructure, industrial processes, building automation, and data centres/
networks, as well as a broad presence in residential applications.
Schneider Electric is dedicated to making individuals and organisations
energy safe, reliable, efficient, productive and green from Power Plant to
Plug
TM
.
We are changing our brand names and becoming one Schneider Electric.
Youll get the same great quality products, but from one name you can remember and
trust. This provides you and your customers with the reassurance associated with
Schneider Electric.
Some of our market leading brands have already become Schneider Electric including
Merlin Gerin, Telemecanique, Square D, GET, Mita, Sarel, Himel, Thorsman,
Tower and TAC.
Working as one Schneider Electric makes it clearer that our ranges are highly compatible
for integrated solutions.
Schneider Electric Ltd
Schneider Electric Limited is a company registered in England and Wales.
Registered number: 1407228. Registered ofce: Stafford Park 5, Telford, Shropshire TF3 3BL.
2014 Schneider Electric. All Rights Reserved. Schneider Electric, Active Energy Management,
Compact, EcoStruxure, ION Enterprise, iRIO, Make the most of your energy, Masterpact,
Micrologic, Power Plant To Plug, Modbus, and PowerLogic are owned by Schneider Electric
Industries SAS, or its afliated companies in the United States and other countries.
As standards, specications and designs change from time to time, please ask for conrmation
of the information given in this publication. S
E
8
3
2
5

J
A
N


2
0
1
4
United Kingdom
Stafford Park 5,
Telford
Shropshire
TF3 3BL
Tel: 0870 608 8 608
Fax: 0870 608 8 606
www.schneider-electric.com/uk
Ireland
Head ofce,
Block a
Maynooth Business Campus
Maynooth, Co. Kildare
Tel: (01) 601 2200
Fax: (01) 601 2201
www.schneider-electric.com/ie