Sie sind auf Seite 1von 5

50/GASTURBINE/xxxx/0406/EN

RIGID POCKET FILTERS


Gas Turbine Model

Typical applications Separators


Cotton threads with hot melt gluing
Gas turbine rigid pocket filters with mini-pleated
extended filtering surface are developed for gas Sealant
turbine and compressor applications. The main Cold moulded polyurethane
advantages of such construction are a low pressure
Frame
loss and a long life time of the filter.
Plastic
With a flange of 25 mm filters may be installed into
standard mounting frames. Gasket
Foamed rubber on the dirty air side

Advantages
Operating temperature
80°C
• Strong plastic frame and rigid construction
guarantee high stability during utilization Relative humidity
• Ease of maintenance Max. 100 %
• Long service life
• Filters are completely incinerable Specifications
• Filters available in classes F7-F9
• Available in two depths: 292 and 420 mm
Technical characteristics
• Burst protection grids available on dirty air side
(2 or 8 grids)
Media
Water resistant dual layer glass fibre paper provides
Quality and environment
a progressive density media with high dust collection
The operations of Halton Clean Air Oy are certified
ability.
with the ISO 9001:2000 Quality and ISO 14001
Environmental standards.

RIGID POCKET FILTERS - Gas Turbine Model



50/GASTURBINE/xxxx/0406/EN
EFFICIENCY

FILTER CLASS Average efficiency, Em % 0,4 µm


CEN - EN 779
F7 80 < Em < 90
F8 90 < Em < 95
F9 95 < Em

DIMENSIONS

25
D
25

W
Pressure drop as a function of the air flow rate (clean device)

NR CODE Dimensions Flow rate Filtering Initial pressure Volume Weight


W

W x L x D mm m 3/h surface m 2 dropL Pa m3 kg


1 CLP - RP - P - 402 - 593 - 292 - 4GT - F7 - GF - P 402 x 593 x 292 3300 11,8 180 0,084 4,00
2 CLP - RP - P - 288 - 593 - 292 - 4GT - F7 - GF - P 288 x 593 x 292 2250 8,5 180 0,060 3,15
3 CLP - RP - P - 491L - 593 - 292 - 4GT - F7 - GF - P 491 x 593 x 292 4100 14,5 180 0,102 4,50
4 CLP - RP - P - 593 - 593 - 292 - 4GT - F7 - GF - P 593 x 593 x 292 5000 18,0 180 0,123 5,50
Recommended final pressure drop < 600 Pa
Maximum final pressure drop < 1000 Pa

2 1 3
250

4
Pressure drop (Pa)

200

150

100

50

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
Air flow rate (m 3/s)

RIGID POCKET FILTERS - Gas Turbine Model



50/GASTURBINE/xxxx/0406/EN
NR CODE Dimensions Flow rate Filtering Initial pressure Volume Weight
W x L x D mm m 3/h surface m 2 drop Pa m3 kg
1 CLP - RP - P - 402 - 593 - 420 - 4GT - F7 - GF - P 402 x 593 x 420 3300 18,00 150 0,100 5,20
2 CLP - RP - P - 288 - 593 - 420 - 4GT - F7 - GF - P 288 x 593 x 420 2250 14,00 150 0,072 4,00
3 CLP - RP - P - 491 - 593 - 420 - 4GT - F7 - GF - P 491 x 593 x 420 4100 22,00 150 0,125 6,00
4 CLP - RP - P - 593 - 593 - 420 - 4GT - F7 - GF - P 593 x 593 x 420 5000 30,00 150 0,150 7,00
Recommended final pressure drop < 600 Pa
Maximum final pressure drop < 1000 Pa

2 1 3 4
200
Pressure drop (Pa)

150

100

50

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000
Air flow rate (m 3/s)

NR CODE Dimensions Flow rate Filtering Initial pressure Volume Weight


W x L x D mm m 3/h surface m 2 drop Pa m3 kg
1 CLP - RP - P - 402 - 593 - 292 - 4GT - F8 - GF - P 402 x 593 x 292 3300 11,8 205 0,084 4,00
2 CLP - RP - P - 288 - 593 - 292 - 4GT - F8 - GF - P 288 x 593 x 292 2250 8,5 205 0,060 3,15
3 CLP - RP - P - 491 - 593 - 292 - 4GT - F8 - GF - P 491 x 593 x 292 4100 14,5 205 0,102 4,50
4 CLP - RP - P - 593 - 593 - 292 - 4GT - F8 - GF - P 593 x 593 x 292 5000 18,0 205 0,123 5,50
Recommended final pressure drop < 600 Pa
Maximum final pressure drop < 1000 Pa

2 1 3
300

250 4
Pressure drop (Pa)

200
SP30 SP29 SP31 SP32
150

100

50

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500
Air flow rate (m 3/s)

RIGID POCKET FILTERS - Gas Turbine Model



50/GASTURBINE/xxxx/0406/EN
NR CODE Dimensions Flow rate Filtering Initial pressure Volume Weight
W x L x D mm m 3/h surface m 2 drop Pa m3 kg
1 CLP - RP - P - 402 - 593 - 420 - 4GT - F8 - GF - P 402 x 593 x 420 3300 18,00 175 0,100 5,20
2 CLP - RP - P - 288 - 593 - 420 - 4GT - F8 - GF - P 288 x 593 x 420 2250 14,00 175 0,072 4,00
3 CLP - RP - P - 491 - 593 - 420 - 4GT - F8 - GF - P 491 x 593 x 420 4100 22,00 175 0,125 6,00
4 CLP - RP - P - 593 - 593 - 420 - 4GT - F8 - GF - P 593 x 593 x 420 5000 30,00 175 0,150 7,00
Recommended final pressure drop < 600 Pa
Maximum final pressure drop < 1000 Pa

2 1 3
250
4

200
Pressure drop (Pa)

150

100

50

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500 5000 5500 6000
Air flow rate (m 3/s)

NR CODE Dimensions Flow rate Filtering Initial pressure Volume Weight


W x L x D mm m 3/h surface m 2 drop Pa m3 kg
1 CLP - RP - P - 402 - 593 - 292 - 4GT - F9 - GF - P 402 x 593 x 292 2200 11,8 120 0,084 4,00
2 CLP - RP - P - 288 - 593 - 292 - 4GT - F9 - GF - P 288 x 593 x 292 1600 8,5 120 0,060 3,15
3 CLP - RP - P - 491 - 593 - 292 - 4GT - F9 - GF - P 491 x 593 x 292 2700 14,5 120 0,102 4,50
4 CLP - RP - P - 593 - 593 - 292 - 4GT - F9 - GF - P 593 x 593 x 292 3400 18,0 120 0,123 5,50
Recommended final pressure drop < 600 Pa
Maximum final pressure drop < 1000 Pa

2 1 3
200

4
Pressure drop (Pa)

150

100

50

0
0 500 1000 1500 2000 2500 3000 3500 4000
3
Air flow rate (m /s)

RIGID POCKET FILTERS - Gas Turbine Model



50/GASTURBINE/xxxx/0406/EN
NR CODE Dimensions Flow rate Filtering Initial pressure Volume Weight
W x L x D mm m 3/h surface m 2 drop Pa m3 kg
1 CLP - RP - P - 402 - 593 - 420 - 4GT - F9 - GF - P 402 x 593 x 420 2200 18,00 110 0,100 5,20
2 CLP - RP - P - 288 - 593 - 420 - 4GT - F9 - GF - P 288 x 593 x 420 16000 14,00 110 0,072 4,00
3 CLP - RP - P - 491 - 593 - 420 - 4GT - F9 - GF - P 491 x 593 x 420 2700 22,00 110 0,125 6,00
4 CLP - RP - P - 593 - 593 - 420 - 4GT - F9 - GF - P 593 x 593 x 420 3400 30,00 110 0,150 7,00
Recommended final pressure drop < 600 Pa
Maximum final pressure drop < 1000 Pa

2 1 3 4
175

150
Pressure drop (Pa)

125

100

75

50

25

0
0 500 1000 1500 2000 2500 3000 3500 4000 4500
3
Air flow rate (m /s)

RIGID POCKET FILTERS - Gas Turbine Model




Das könnte Ihnen auch gefallen