The selection of elevators should be made in consideration of the building type/scale, tenant
characteristics, elevator usage and the anticipated passenger carrying capacity at the
building
s traffic peak time.
Hyundai elevators are available from machine-room-less elevators to low-medium and ultra
high-speed elevators, covering the full range of vertical transportation requirements.
ELEVATORS
And a variety of functional and attractive designs per usages, such as passenger, service,
observation, hospital bed, freight and automobile elevators are offered for architectsand
customers
flexible applications.
MOVING WALKS
Speed
Operation
60
Kinds of Building
Usage
Control
Low-Rise Apartment
Low-Rise Building
Passenger
Observation
Hospital
Mid-Rise Apartment
Mid-Rise Building
Passenger
Observation
Hospital
60 ~ 150
Geared
High-Rise Apartment
High-Rise Building
Passenger
Gearless
Parking Building
Automobile
General Traction
30, 45
General Traction
30, 45, 60
Hydraulic
20, 30, 45
(m/min)
Geared
ESCALATORS
Contents
Selection Of Elevator System
03
04
06
08
10
12
14
16
18
20
22
Factory, Warehouse
Single Automatic
Single Automatic
1 Car : Selective Collective
2 Cars : Duplex Selective Collective
Freight
Note : The table shows the common method of elevator system selection per usages.
F/
23
Capacity
(Persons/kgs)
24
25
Speed
(m/min)
ST
No. of Stop
Floors
30
31
32
33
34
36
37
Usage
39
MRL
MP
MS
MPF
MOB
MB
MF
MA
General Traction
P
S
(PF)
OB
B
F
A
40
Hydraulic
HP
HS
(HPF)
HOB
HB
HF
HA
Single
Double
Entrance Entrance
CO
COD
2S
2SD
2CO
2COD
2U
2UD
3S
3SD
3U
3UD
Type
2-Panel Center Opening
2-Panel Side Opening
4-Panel Center Opening
2-Panel Up-Sliding
3-Panel Side Opening
3-Panel Up-Sliding
PASSENGER ELEVATORS
Gearless Elevators60~150m/min
Section of Hoistway
MX1
A
M/C Room
Height (MH)
CB
Vent
Grille
(By
others)
VentGrille
Grille(By
(Byothers)
others)
Vent
Vent
Grille
(By
others)
Vent
Grille
(By
others)
R1
Capacity
Speed
(m/min)
X1
Overhead (OH)
MY
Control
Panel
X1
X2
X3
450
800
1400 850
14601005
1800
3700
5600
550
800
14001030
14601185
1800
3700
600
800
14001130
14601285
1800
10
700
800
14001250
14601405
11
750
800
14001350
13
900
900
15
1000
17
1150
60
105
120
X2
A
R1
CB
OP
R2
R2
Control
Panel
Control
Panel
R3
Receptacle
(By others)
Distribution Board
(By others)
Ladder
(By others)
MY
R1
R2
R3
R4
1430
2000
4000
6000
3200
3600
2000
5400
4500
5600
1610
2000
4000
6000
3400
4050
2250
6000
4900
3700
5600
1710
2000
4000
6000
3500
4100
2450
6300
5100
1800
3700
5600
1830
2000
4000
6000
3600
4200
2700
6800
5400
14601505
1800
3700
5600
1930
2000
4000
6000
3700
4550
2800
7100
5600
16001350
16601505
2050
4200
6350
1980
2300
4400
6800
3750
5100
3750
8100
6300
900
16001500
16601655
2050
4200
6350
2130
2300
4400
6800
3850
5450
4300
8600
6600
1000
18001500
19001670
2350
4800
7250
2180
2600
4900
7500
3900
6600
5100
11000
8700
1100
20001350
21001520
2550
5200
7850
2030
2800
5250
8300
3800
1000
18001700
19001870
2350
4800
7250
2380
2600
4900
7500
4200
7800
6000
12200
9500
1100
20001500
21001670
2550
5200
7850
2180
2800
5250
8300
4000
20001750
21001920
2550
5200
7850
2430
2900
5400
8300
4300
8500
6800
13600 10400
21501600
22501770
2700
5500
8300
2280
3000
5650
8700
4200
1350
1600
1100
Notes : 1. Above hoistway dimensions are based on 15-storied buildings. For application to over 16-storied buildings,
the hoistway dimensions shall be at least 5% larger considering the sloping of the hoistways.
2. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai.
3. When non-standard capacities and dimensions are required to meet the local code, consult Hyundai.
4. The capacity in persons is calculated at 65kg/person. (EN81=75kg/person)
5. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over 1000mm
is applied, hoistway size for 1 car should be applied above X1 dimension plus 100mm.
6. In case of 120m/min and 150m/min, hoistway size is above plus 100mm, the machine room size is above plus 100mm.
MY
CA
OP
20
24
X1
R1
Note 6
150 Note 6
2100
MX2
AB
90
External
CA CB
Travel (TR)
Distribution Board
(By others)
Internal
OP
CA
OP
R2
Clear
Opening
M/C Room
kg
Cinder
Concrete Min. 150
(By others)
R1
Hoistway
Persons
Suspension Hook
(By others)
R2
Car
R4
Waterproof Finish
(By others)
(Unit : mm)
Speed
(m/min)
MX3
X3
R1
Beam
Beam
(By
(By
others)
others)
Beam(By
(Byothers)
others)
Beam
Beam
(By
others)
Beam
Beam
(By
(By
others)
others)
B
Y
CB
Pit
(PP)
60
4600
1500
2200
90
4800
1800
2400
105
5000
2100
2400
120
5000
2100
2600
150
5500
2400
2600
OP
OP
OP
R2
R2
R2
Control
Panel
Control Control
Panel
Panel
Distribution Board
(By others)
MY
CA
R1
X2
X1
A
R1
Overhead
(OH)
PASSENGER ELEVATORS
Machine-Room-Less Elevators60~150m/min
Section of Hoistway
Clear
Car
Speed Capacity Opening
(m/min) Persons kg
OP
CACB
AB
X
R4
90
Traction
Machine
CA
R2
OP
800
600
7000
1600
8~17
45, 60
3800
1500
530
90
3900
1800
530
530
4300
2200
530
150
4600
2400
530
45, 60
4200
1500
530
600
800
5.6
600
7300
1600
13~17
6.5
4.3
10
700
800
6.5
650
7800
1600
20~24
90
4300
1800
630
105
4500
2100
630
630
105
7.5
120
4800
2200
60
4.6
150
5100
2400
630
45, 60
4400
1750
530
90
11
750
800
6.9
105
8.1
60
5.7
13
900
930
(HC)
900
150
15601555 2200
1850
15001400 16601505 2300
16001350
16001570 2400 2100
17001520 2500 2250
60
90
105
15
1000
900
120
16001400
1900
16601555 2300
(2100)
17001570 2500
150
8.6
11.5
14.5
9.2
2100
12.3
15.4
7.1
10.6
1000
18001400 19001570
2600 2100
20
1350
1000
2650 2250
17.7
2650
12.5
18001600 19001770
2400
20.7
90
14.8
2850
24
1600
1100
120
20001600 21001770
2450
2880
150
60
1750
1200
1900
38
900
11200
2300
800
9800
2000
900
11800
2500
900
12500
2500
900
14200
2700
3000
3100
3200
3300
2800
3300
3700
1900
630
4600
2100
630
45, 60
5000
1750
630
90
5100
1900
630
105
5300
2100
630
17.2
19.7
24.6
17.2
20.1
60
12.3
30
2000
1200
105
18.4
21.5
60
105
9200
4500
11.5
27
105
90
750
90
105
9.9
60
90
14.5
16.6
2680
150
90
27~30
8.3
120
105
1700
12.4
14.1
90
105
8100
10.8
90
1150
700
6.2
60
17
10
2250
60
R5
120
120
Waterproof Finish
(By others)
5.1
3.7
150
Lighting
(By others)
R6
60
90
Ladder
(By others)
R5
2100
105
Receptacle
(By others)
R4
Control
Panel
(CP)(*)
4000
105
OP
R3
Pit
(PP)
105
90
Control
Control
Control
Control
Control
Control
Panel
Panel
Panel
Panel
Panel
Panel
R2
Speed Overhead
(m/min) (OH)
5.9
120
CP
(*)
550
60
R3
R1
Persons
3.4
105
CB
Top floor
(By others)
Motor
(kW)
( : mm)
105
90
60
Lighting
(By others)
Distribution Board
(By others)
Hoistway
15.4
38
2500
1400
23
26.9
Notes : 1. When non-standard capacities and dimensions (including fire protection doors) are required to meet the local code, please
consult Hyundai.
2. The minimum hoistway dimensions are shown on the above table. Therefore, some allowances should be made considering
the sloping of the hoistways.
3. If the height of floor is over 11m, please consult Hyundai as to the needs for emergency exit.
4. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over
1000mm is applied, hoistway size for 1car should be applied above X1 dimension plus 100mm.
5. In case the emergency stop switch is applied to the counter weight, consult Hyundai.
6. When face to face arrangement is required, partitioning work for hoistway is required. (EN81)
PASSENGER ELEVATORS
Geared Elevators60~105m/min
Section of Hoistway
MX1
R1
Overhead (OH)
CB
MY
CA
Persons kg
Cinder
Concrete Min. 150
(By others)
R2
A
R1
Capacity
Speed
(m/min)
Suspension Hook
(By others)
M/C Room
Height (MH)
X1
60
OP
R2
90
R1
R1
Beam
(By others)
CB
A
R1
CB
X2
CA
R2
Control
Panel
Control
Panel
Distribution Board
(By others)
X2
X3
MX1
MX2
MX3
MY
R1
R2
R3
R4
14601005
1800
3700
5600
1430
2000
4000
6000
3200
3600
2000
5200
4300
550
800
14001030
14601185
1800
3700
5600
1610
2000
4000
6000
3400
4050
2250
5800
4700
600
800
14001130
14601285
1800
3700
5600
1710
2000
4000
6000
3500
4100
2450
6100
4900
10
700
800
14001250
14601405
1800
3700
5600
1830
2000
4000
6000
3600
4200
2700
6600
5200
11
750
800
14001350
14601505
1800
3700
5600
1930
2000
4000
6000
3700
4550
2800
6900
5400
13
900
900
16001350
16601505
2050
4200
6350
1980
2300
4400
6800
3750
5100
3750
7900
6100
15
1000
900
16001500
16601655
2050
4200
6350
2130
2300
4400
6800
3850
5450
4300
8400
6400
1000
18001500
19001670
2350
4800
7250
2180
2600
4900
7500
3900
17
1150
6600
5100
10800
8500
1100
20001350
21001520
2550
5200
7850
2030
2800
5250
8300
3800
1000
18001700
19001870
2350
4800
7250
2380
2600
4900
7500
4200
7800
6000
11800
9100
1100
20001500
21001670
2550
5200
7850
2180
2800
5250
8300
4000
20001750
21001920
2550
5200
7850
2430
2900
5400
8300
4300
8500
6800
13100
9900
21501600
22501770
2700
5500
8300
2280
3000
5650
8700
4200
1350
1600
1100
OP
OP
OP
OP
OP
OP
OP
OP
OP
OP
OP
OP
OP
OP
OP
OP
OP
OP
R2
R2
R2
Control
Panel
Control
Panel
Control
Panel
Distribution Board
(By others)
Speed
(m/min)
Overhead
(OH)
Pit
(PP)
60
4600
1500
2200
90
4800
1800
2400
105
5000
2100
2400
Notes : 1. The minimum hoistway dimensions are shown on the above table. Therefore, some allowances
should be made considering the sloping of the hoistways.
2. Machine room temperature should be maintained below 40C with ventilating fan and/or air
conditioner (if necessary) and humidity below 90%.
3. The minimum machine room height should be 2800mm in case of the traction machine with double
isolation pad.
R2
OP
MY
MY
CA
X1
(Unit : mm)
X1
Vent Fan (By others)
OP
Vent Grille (By others)
2100
X3
R1
AB
Waterproof Finish
(By others)
MX3
Ladder
(By others)
X2
X1
CA CB
Notes : 1. Above hoistway dimensions are based on 15-storied buildings. For application to over 16-storied buildings,
the hoistway dimensions shall be at least 5% larger considering the sloping of the hoistways.
2. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai.
3. When non-standard capacities and dimensions are required to meet the local code, consult Hyundai.
4. The capacity in persons is calculated at 65kg/person. (EN81=75kg/person)
5. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over 1000mm is applied,
hoistway size for 1 car should be applied above X1 dimension plus 100mm.
MX2
R1
OP
1400 850
24
Receptacle
(By others)
800
20
M/C Room
450
105
Travel (TR)
Hoistway
Control
Panel
Distribution Board
(By others)
Car
Clear
Opening Internal
External
(Unit : mm)
HIGH-SPEED/ULTRA-HIGH-SPEED ELEVATORS
Gearless Elevators180~600m/min
Section of Hoistway
Hook or Trolly Beam
(By others)
MX3
X3
R2
R2
R2
R2
Control Panel
Travel (TR)
R2
Entrance
Height
Receptacle
(By others)
Ladder
(By others)
Waterproof Finish
(By others)
MX3
X3
420
480
540
600
R1
Beam
(By others)
R1
Beam
(By others)
Internal
External
1Car
M/C Room
M/C Room
2Cars 3Cars Depth Reaction (kg)
OP
CA CB
AB
X1
X2
X3
MX1
MX2
MX3
MY
R1
R2
13
900
900
16001350
17001520
2300
4550
6900
2150
2800
5500
7900
4500
12030
6630
15
1000
900
16001500
17001670
2300
4550
6900
2300
2800
5500
7900
4700
12810
6950
17
1150
1000
18001500
19001670
2500
4950
7500
2350
3000
6100
8800
4700
1100
20001350
21001520
2700
5350
8100
2200
3200
6250
9100
4500
13080
7130
20
1350
1000
18001700
19001870
2500
4950
7500
2550
3000
6100
8900
5000
1100
20001500
21001670
2700
5350
8100
2350
3200
6250
9100
4700
14360
7650
24
1600
20001750
21001920
2700
5350
8100
2600
3200
6250
9100
5000
21501600
22501770
2850
5650
8550
2450
3400
6500
9400
4900
15090
8080
15
1000
900
16001500
17001670
4600
6950
2350
5600
8200
4900
1000
18001300
19001470
5000
7550
2150
5800
8400
4900
12810
7800
17
1150
1000
18001500
19001670
5000
7550
2350
6100
8900
4900
1100
20001350
21001520
5400
8150
2200
6200
9000
4900
14100
8000
20
1350
1000
18001700
19001870
5000
7550
2550
6100
8800
5000
1100
20001500
21001670
5400
8150
2350
6200
9000
5000
15100
8050
24
1600
20001750
21001920
5400
8150
2600
6400
9000
5000
21501600
22501770
5700
8650
2450
6500
9400
5000
15700
8100
20
1350
10 00
18001700
19001920
5100
7700
2650
6200
9100
6000
1100
20001500
21001720
5500
8300
2450
6200
9100
5900
17800
13200
24
1600
1100
20001750
21001970
5500
8300
2650
6500
9100
6300
21501600
22501820
5800
8750
2500
6500
9400
6200
18100
13500
17
1150
1000
18001500
7800
2500
8900
6000
20
1350
1100
20001500
8750
2500
9500
6300
24
1600
1100
20001750
8750
2750
9500
6300
1100
1100
CB
CA
(Unit : mm)
MY
OP
Min. 200
OP
OP
CP
CP
R1
B
R2
Distribution Board
(By others)
Y
3600 ~ 4000
MY
OP
R2
CP
CP
Vent Fan
(By others)
OP
Machine Room
Access Door
(By others)
900 (W) X 2000 (H)
OP
R2
X1
Hoistway
Notes : 1. The minimum hoistway dimensions are shown on the above table. Therefore, some allowances should be made considering the sloping of the hoistways.
2. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai.
3. For elevators with more than 28 persons capacity, consult Hyundai.
4. When non-standard capacities and dimensions are required to meet the local code, consult Hyundai.
5. The capacity in persons is calculated at 65kg/person. (EN81=75kg/person)
6. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over 1000mm is applied, hoistway size for 1 car should be applied
above X1 dimension plus 100mm.
7. The maximum speed capabilities of Hyundai is 1080m/min. Consult Hyundai.
MX2
X2
CA
CP
CP
R1
CB
R1
Min. 200
X2
X1
A
Car
Clear
Opening
kg
300
360
Face-to-Face Arrangement
(Unit : mm)
Persons
210
240
Capacity
180
OP
OP
MY
CA
OP
R1
2100
CB
R1
Overhead (OH)
R1
Beam
(By others)
R1
Speed
(m/min)
Suspension
Cinder Concrete
Min. 150
(By others)
M/C Room
Height
(MH)
X2
X1
A
R1
OP
OP
R2
R2
Control
Panel
Control
Panel
Distribution Board (By others)
Speed
(m/min)
Overhead
(OH)
Top Clearance
(TC)
Pit
(PP)
M/C Room
Height (MH)
Speed
(m/min)
Overhead
(OH)
Top Clearance
(TC)
Pit
(PP)
M/C Room
Height (MH)
180
6000
2300
2700
2500
420
8500
4200
6000
3200
210
6400
2700
3200
2800
480
9500
5700
6400
3500
240
7100
3350
3850
2800
540
9750
5950
8800
3500
300
8000
4000
4200
3000
600
10000
6200
9000
3500
360
8300
4000
4300
3000
Notes : 1. The above table shows minimum figures. Therefore, some allowances should be made considering errors that may occur during construction.
2. Above dimensions are applied in case car height is 2800mm. In case car height is over 2800mm, overhead should be applied above dimension plus additional height.
10
11
OBSERVATION ELEVATORS
Gearless & Geared Elevators60~105m/min
Section of Hoistway
MX
1 Side Type
Type
Min.
500
Maintenance Deck
(By others)
Receptacle
(By others)
2 Side Type
Waterproof Finish
(By others)
60
90
105
Clear
Opening
Internal
External
Hoistway
M/C Room
M/C Room
Reaction (kg)
Pit Reaction
(kg)
Persons
kg
OP
CA CB
AB
XY
MX MY
R1
R2
450
800
1400850
14601060
22001400
26002900
5000
2700
6650
5750
550
800
14001030
14601240
22001500
26003000
5350
3000
7300
6200
600
800
14001130
14601340
22001600
26003100
5550
3100
7600
6400
10
700
800
14001250
14601460
22001750
26003200
5900
3300
8200
6800
11
750
800
14001350
14601560
22001850
26003350
6100
3400
8500
7000
13
900
900
16001350
16601560
24001850
30003350
6800
3750
9550
7750
15
1000
900
16001500
16601710
24002000
30003500
7100
3900
10100
8150
17
1150
1000
18001500
19001710
28502000
35003500
8900
5300
12800
10500
20
1350
1000
18001700
19001910
28502200
35003700
9000
6650
14100
11400
24
1600
1100
20001750
21001960
30502250
37003750
9850
7050
15500
12300
550
800
14001030
14601240
22001500
26003000
5400
3050
7500
6400
600
800
14001130
14601340
22001600
26003100
5600
3120
7800
6600
10
700
800
14001250
14601460
22001750
26003200
5950
3350
8400
7000
11
750
800
14001350
14601560
22001850
26003350
6100
3450
8700
7200
13
900
900
16001350
16601560
24001850
30003350
6850
3750
9750
7950
15
1000
900
16001500
16601710
24002000
30003500
7150
3930
10350
8350
17
1150
1000
18001500
19001710
28502000
35003500
9000
5400
13000
10700
20
1350
1000
18001700
19001910
28502200
35003700
9100
6700
14250
11600
24
1600
1100
20001750
21001960
30502250
37003750
9950
7100
15700
12500
R3 (Car) R4 (CWT)
Control
Panel
Distribution Board
(By others)
(Unit : mm)
Machine Room
Access Door (By others)
Min. 900 (W)2100 (H)
OP
R2
CB
R1
Vent Fan (By others)
Y
B
A
Glass Wall
(By others)
MY
2-Side
Observation
(Unit : mm)
Car
Notes : 1. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors. Consult Hyundai.
2. When non-standard capacities and dimensions are required to meet the local code, consult Hyundai.
3. The capacity in persons is calculated at 65kg/person. (EN81=75kg/person)
4. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over
1000mm is applied, hoistway size for 1 car should be applied above X1 dimension plus 100mm.
MX
CA
Ladder
(By others)
60
90
105
Travel (TR)
Distribution Board
(By others)
2100
Control
Panel
Cinder
Concrete Min. 150
(By others)
1-Side
Observation
Capacity
Speed
(m/min)
Suspension Hook
(By others)
M/C Room
Height (MH)
Overhead (OH)
CB
OP
Machine Room
Access Door (By others)
Min. 900 (W)2100 (H)
CA
MY
R2
R1
Y
B
A
Glass Wall
(By others)
12
Speed
(m/min)
Overhead
(OH)
Pit
(PP)
M/C Room
Height (MH)
60
4700
1750
2200
90
4900
1800
2400
105
5000
2100
2400
Notes : 1. The minimum hoistway dimensions are shown on the above table. Therefore, some
allowances should be made considering the sloping of the hoistways.
2. The minimum machine room height should be 2800mm in case of the traction
machine with double isolation pad.
3. For gearless (1:1 roping) elevators, the minimum machine room height should be
2400mm.
13
OBSERVATION ELEVATORS
Gearless & Geared Elevators60~105m/min
Section of Hoistway
X2, MX2
M/C Room
Height (MH)
60
4800
1800
2200
5000
2050
2400
105
5100
2050
2400
Ladder
(By others)
Speed
(m/min)
60
90
105
Capacity
Clear
Opening
Internal
External
CA CB
AB
Persons
kg
OP
11
750
800
13
900
15
1000
17
X1
X2
14001400 14601610
2450
5100
2000
900
16001450 16601660
2650
5500
900
16001570 16601780
2650
5500
1150
1000
18001580 19001790
2850
20
1350
1000
18001800 19002010
24
1600
1100
18002000 19002210
Pit Reaction
(kg)
R2
R2
(1Car)
(2Cars)
6150
3450
3550
6900
3700
7200
6100
3700
9100
3500
6100
3900
9150
3500
6100
MX1 MX2
MY
R1
1200
2900
5100
3500
2050
1350
3300
5500
2200
1350
3300
5500
6100
2200
1600
3500
2850
6100
2400
1600
2850
6100
2600
1600
Notes : 1. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai.
2. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over 1000mm is applied,
hoistway size for 1 car should be applied above X1 dimension plus 100mm.
3. Consult Hyundai if the capacity is 10 persons and less.
14
M/C Room
Reaction (kg)
Pit
(PP)
M/C Room
Height (MH)
60
4800
1800
2200
90
5000
2050
2400
105
5100
2050
2400
Min.
500
Maintenance
Deck
(By others)
R4 R3
Receptacle
(By others)
Ladder
(By others)
Waterproof Finish
(By others)
Capacity
External
CA CB
AB
R4
Persons
kg
OP
6900
8700
7150
11
750
800
3750
7500
9700
7900
3950
60
90
105
Hoistway
Internal
R3
(Unit : mm)
Car
Clear
Opening
2100
Travel (TR)
Overhead
(OH)
Ent. Height(EH)
Overhead (OH)
R1
S
Vent Fan (By others)
Speed
(m/min)
R2
MY
(Unit : mm)
M/C Room
Semicircle Type
Notes : 1. The minimum hoistway dimensions are shown on the above table. Therefore, some
allowances should be made considering the sloping of the hoistways.
2. The minimum machine room height should be 2800mm in case of the traction
machine with double isolation pad.
3. Above dimentions are changeable according to the car exterior design.
Hoistway
Control
Panel
Distribution Board
(By others)
Waterproof Finish
(By others)
R1
Receptacle
(By others)
OP
Control
Panel
Overhead (OH)
Maintenance Deck
(By others)
OP
R4 R3
Notes : 1. The minimum hoistway dimensions are shown on the above table. Therefore, some
allowances should be made considering the sloping of the hoistways.
2. The minimum machine room height should be 2800mm in case of the traction
machine with double isolation pad.
3. Above dimentions are changeable according to the car exterior design.
Car
CA
Pit
(PP)
90
CB
Overhead
(OH)
Min.
500
Speed
(m/min)
Cinder
Concrete Min. 150
(By others)
3 Side Type
550
Travel (TR)
Distribution Board
(By others)
Cinder
Concrete Min. 150
(By others)
Control
Panel
Suspension Hook
(By others)
200
R1
OP
Control
Panel
MY
OP
M/C Room
Height (MH)
550
CB
R2
R1
CA
Section of Hoistway
X2, MX2
Suspension Hook
(By others)
550
200
A
Glass Enclosure
(By others)
550
M/C Room
Height (MH)
M/C Room
X1
X2
14001480 14601690
2450
5100
2000
M/C Room
Reaction (kg)
R2
R2
(1Car)
(2Cars)
6180
3450
MX1 MX2
MY
R1
1200
2900
5100
3500
Pit Reaction
(kg)
R3
R4
6900
8700
7150
9700
7900
13
900
900
16001500 16601710
2650
5500
2050
1350
3300
5500
3550
6930
3750
7500
15
1000
900
16001650 16601860
2650
5500
2200
1350
3300
5500
3700
7220
3950
17
1150
1000
18001650 19001860
2850
6100
2200
1600
3500
6100
3700
9100
20
1350
1000
18001900 19002110
2850
6100
2400
1600
3500
6100
3900
9150
24
1600
1100
18002130 19002340
2850
6100
2600
1600
3500
6100
Notes : 1. Above dimensions are based on center opening doors. For applicable dimensions with side opening doors, consult Hyundai.
2. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over 1000mm is applied,
hoistway size for 1 car should be applied above X1 dimension plus 100mm.
3. Consult Hyundai if the capacity is 10 persons and less.
15
OBSERVATION ELEVATORS
Machine-Room-Less Elevaotrs60 ~105m/min
Section of Hoistway
1 Side Type
A
R4
R1
Top floor
(By others)
R2
Lighting
(By others)
2 Side Type
A
R1
CA
CB
Top floor
(By others)
OP
R2
Travel (TR)
2-Side
Observation
R3
90
105
R4
60
OP
1-Side
Observation
R3
Traction
Machine
CB
CA
Lighting
(By others)
60
90
105
Receptacle
(By others)
Ladder
(By others)
Lighting
(By others)
Waterproof Finish
(By others)
R5
Control
Panel
Car
Internal
External
M/C Room
Reaction (kg)
Hoistway
Pit Reaction
(kg)
Persons
kg
OP
CA CB
AB
XY
R4
R5
R6
550
800
13001090
13601300
21001700
700
7500
6400
600
800
13001160
13601370
21001800
750
7800
6600
10
700
800
13001300
13601510
21001850
800
8400
7000
11
750
800
13001400
13601610
21001900
900
8700
7200
15001400
15601610
23001900
16001350
16601560
24001850
9750
7950
13
900
930 (HC)
900
R1
R2
R3
15
1000
900
16001400
16601610
23001950
8350
17
1150
1000
18001400
19001610
26002150
10700
20
1350
1000
18001600
19001810
26502450
11600
24
1600
1100
20001600
21001810
28502500
12500
550
800
13001090
14601300
22001700
750
7700
6600
600
800
13001160
14601370
22001800
800
8000
6800
10
700
800
13001300
14601510
22001850
850
8600
7200
11
750
800
13001400
14601610
22001900
950
8900
7400
15001400
15601610
24001900
16001350
16601560
25001850
9950
8150
13
900
930 (HC)
900
15
1000
900
16001400
17601610
24001950
8550
17
1150
1000
18001400
19601610
27002150
10900
20
1350
1000
18001600
19601810
27002450
11800
24
1600
1100
20001700
21601910
29002500
12700
Notes : 1. When non-standard capacities and dimensions (including fire protection doors) are required to meet the local code, please consult Hyundai.
2. The minimum hoistway dimensions are shown on the above table. Therefore, some allowances should be made considering the sloping of the hoistways.
3. The capacity in persons is calculated at 65kg / person. (EN81=75kg / person)
4. If the height of floor is over 11m, please consult Hyundai as to the needs for emergency exit.
5. Above dimensions are applied in case the door is standard. In case fire protection door that the clear opening is over 1000mm is applied, hoistway size for
1 car should be applied above X1 dimension plus 100mm.
6. In case the emergency stop switch is applied to the counter weight, consult Hyundai.
7. If the car is heavier than 1000kg because of interior decoration in case of elevator for 15 persons (1000kg), consult Hyundai.
Persons
8 ~ 15
CP
(*)
16
Clear
Opening
R6
Distribution Board
(By others)
OP
Capacity
Speed
(m/min)
(Unit : mm)
17
20 ~24
Speed
(m/min)
Overhead
(OH)
Pit
(PP)
60
4250
1750
Control Panel
(CP)(*)
530
90
4350
1800
105
4400
2000
60
4250
1800
90
4350
1900
105
4400
2000
60
4850
1800
530
90
5000
1900
630
105
5000
2100
630
Notes : 1. Above dimensions are applied for car height of 2500mm (car internal height is
2300mm), For other applicable dimensions, consult Hyundai.
2. The minimum hoistway dimensions are shown on the above table. Therefore, some
allowances should be made considering the sloping of the hoistways.
3. When face to face arrangement is required, partitioning work for hoistway is
required. (EN81)
4. If the hoistway is glass, consult Hyundai as it needs to finish joining glass. (EN81)
5. The lighting should be installed at the top and bottom of hoistway.
6. When non-standard capacities and dimensions are required to meet the local code,
please consult Hyundai Elevator.
530
17
Section of Hoistway
Lighting (By others)
Type
kg
XY
MX MY
R1
R2
550
800
14001030
15601240
23001500
27003000
5450
3035
7800
6700
600
800
14001130
15601340
23001600
27003100
5640
3150
8200
7000
10
700
800
14001250
15601460
23001750
27003200
6010
3370
8750
7350
11
750
800
14001350
15601560
23001850
27003350
6180
3480
9300
7800
13
900
900
16001350
17601560
25001850
31003350
6930
3795
10350
8550
15
1000
900
16001500
17601710
25002000
31003500
7220
3970
11050
9050
17
1150
1000
18001500
19601710
27502000
36003500
9100
5440
13650 11350
20
1350
1000
18001700
19601910
28902200
36003700
9144
6760
15300 12600
24
1600
1100
20001750
21601960
30902250
38003750
10020
7190
16800 13600
45
Glass walled
Elevators
Over head (OH)
Total Height (TH)
Travel (TR)
Distribution Board
(By others)
Receptacle
(By others)
4500
1500
2200
60
4700
1500
2200
90
4900
1800
2400
105
5000
2100
2400
(Machine-Room-Less)
MRL
Waterproof Finish
(By others)
R5
R3
External
AB
Hoistway
M/C Room
Notes : 1. The machine room reactions are changeable according to the size of hoistway and
center of car weight.
2. The same dimension of passenger elevators apply to the others except the above.
3. For NDFL-01 (Frameless Glass-walled elevators) type, consult Hyundai Elevator
since hoistway dimension and machine room reactions for NDFL-01 type are
changeable under different conditions.
Lighting
(By others)
Internal
CA CB
45
Ladder
(By others)
Lighting
(By others)
90
Gallery Window
(By others)
60
105
Machine Room
Access Door (By others)
Min. 900 (W)2100 (H)
OP
Control
Panel
R2
CB
R1
CA
MY
Pit
Reaction (kg)
R5
R6
MX
Traction
Machine
M/C Room
Reaction (kg)
Persons
Car
Clear
Opening
OP
Capacity
Speed
(m/min)
(Unit : mm)
Speed
(m/min)
R6
(Unit : mm)
Pit
Reaction (kg)
R5
R6
Persons
kg
Clear
Opening
OP
XY
R1
R2
R3
R4
550
800
13001100
14601310
21301750
4295
1870
660
1960
8150
7050
14601400
21301800
Capacity
45
Glass walled
Elevators
Car
60
90
105
R1
Internal
CA CB
External
AB
Hoistway
600
800
13001190
4515
1910
740
2010
8500
7300
10
700
800
13001300
14601510
21301850
4820
2030
840
2100
9050
7650
11
750
800
13001400
14601610
21301900
4975
2030
910
2110
9450
7950
13
900
900
15001400
16601610
23301900
5480
2240
1010
15
1000
900
16001400
17601610
24301900
5840
2385
1077
17
1150
1000
18001400
19601610
27002150
6745
3220
1154
20
1350
1000
18001600
19601810
27502350
7810
4515
1310
24
1600
1100
20001700
21601910
29502400
8345
4650
1480
Distribution Board
(By others)
CB
CA
Control
Panel
OP
R4
R2
OP
CP
(*)
Speed (m/min)
45 / 60
90
105
18
Persons
Overhead (OH)
Pit (PP)
Speed (m/min)
Max.15
4200
1500
45
4850
17
4200
1600
60
4850
4300
1800
90
4400
2000
105
Max.17
Persons
20 / 24
Overhead (OH)
Pit (PP)
1600
5000
1800
5000
2100
Notes : 1. The machine room reactions are changeable according to the size of hoistway and center of car weight.
2. The same dimension of passenger elevators apply to the others except the above.
3. For NDFL-01 (Frameless Glass-walled elevators) type, consult Hyundai Elevator since hoistway dimension
and machine room reactions for NDFL-01 type are changeable under different conditions.
19
FREIGHT ELEVATORS
General Type (2S, 2U, 3U)
Section of Hoistway
MX
Model
X
A
M/C Room
Height (MH)
Vent Fan
(By others)
F0750-2S
Cinder
Concrete Min. 150
(By others)
F1000-2S
30
45
60
2S
30
45
60
2S
30
45
60
2S
30
45
60
2S
Car
Internal
External
CA CB
AB
Standard
11002100
Double
Entrance
Double
Entrance
XY
M/C Room
Buffer
M/C Room Reaction (kg) Reaction (kg)
Overhead (MXMY)
(OH)
R1
R2
R3
R4
18001857 25002150
17001650
4800
28003200 6200
4100
5000
4300
4800
32003500 8500
5700
7100
6100
4800
9000
7500
4800
4600
4800
4600
4800
5000
5300
5500
18001989 25002320
Standard
14002100
Hoistway
19502078 27502400
18501850
19502226 27502600
Machine Room
Access Door (By others)
Min. 900 (W)2000 (H)
CA
OP
F1500-2S
Overhead (OH)
MY
R2
CB
R1
Suspension Hook
(By others)
Entrance
Speed
Door
(m/min) Opening WidthHeight Entrance
(OPEH)
Type
Type
(Unit : mm)
F2000-2S
F2500-2S
Travel (TR)
F2000-2U
F3000-2U
OP
50
50
Min. 300
Min. 650
Wall+Finished
200
30
F2500-2U
Receptacle
(By others)
F3500-2U
Ladder
(By others)
R3
R4
Waterproof Finish
(By others)
F4000-3U
F5000-3U
Standard
30
45
60
2U
30
45
(60)
2S
30
45
(60)
30
45
30
45
25
30
25
30
17002100
Double
Entrance
17002100
18002100
24002928 33003250
Double
Entrance
24003076 33003450
25002100
23002700
24002898 33003250
Double
Entrance
24003016 33003490
Standard
26003228 35003600
Double
Entrance
26003376 35003750
Standard
2U
22002876 30003250
Standard
Standard
23002100
22002728 30003050
21002500
25003000
26003198 35003600
Double
Entrance
26003316 35003800
Standard
2U
27002300
Double
Entrance
28003498 37003900
27003300
28003616 37004100
Standard
2U
28002500
Double
Entrance
30203998 40504400
28003800
30204116 40504600
Standard
3U
30002800
Double
Entrance
32204758 42505250
30004500
32204936 42505520
Standard
3U
32003000
Double
Entrance
34205258 44505750
32005000
34205436 44506020
Wall+Finished
250
30
Notes : 1. Please consult Hyundai when the loading capacity is over 5000kg or the car is non-standard size.
2. The loading capacity should be over 250kg/m2 minimally.
3. The actual reaction may slightly differ from above dimensions in line with machine beam position.
50
Min. 650
OP
50
20
(Unit : mm)
Min. 300
Speed
(m/min)
Pit
(PP)
M/C Room
Height (MH)
30 / 45
1250
2400
60
1500
2600
21
FREIGHT ELEVATORS
AUTOMOBILE ELEVATORS
Section of Hoistway
Section of Hoistway
X
Min. 650
Suspension Hook
(By others)
Cinder
Concrete Min. 150
(By others)
Waterproof Finish
(By others)
OP
R1
Min. 300
Control
Panel
Pit
(PP)
Travel
(TR)
20 / 30 / 45
2100
4100
1400
2000
20m
Travel (TR)
Waterproof Finish
(By others)
250
Speed
(m/min)
Overhead
(OH)
Pit
(PP)
30 / 45
4400
1200
2400
Wall+Finished
Overhead
(OH)
Ladder
(By others)
(Unit : mm)
(Unit : mm)
Ent. Height
(EH)
Receptacle
(By others)
Notes : 1. Consult Hyundai if the actual size is less than the above minimum floor height.
2. The left and right minimum size should be 650mm and 300mm respectively for the
installation of driving part.
Speed
(m/min)
25
50
MX
30
Ladder
(By others)
130
OP
Overhead (OH)
R2
250
Wall+Finished
50
Min. 650
Y
B
200
200
200
200 30
200
200
30
Receptacle
(By others)
Min. 300
50
OP
R2
R1
Travel (TR)
50
OP
50
50
Min. 650
MY
MX
Power Unit
Machine Room
Access Door (By others)
Min. 900 (W)2000 (H)
200 30
Vent Grille
(By others)
CA
Control
Panel
CB
Power Unit
MY
(Hydraulic hose)
Machine Room
Access Door
Distribution Board
[By others]
Min
Min
Min
Min 900 (W)2000 (H) [By others]
Min
R2
R1
OPB
CA
CB
Overhead (OH)
M/C Room
Height (MH)
600
Min. 300
50
OP
50
(Unit : mm)
Entrance
WidthHeight
(OPEH)
Internal
CACB
External
AB
XY
MXMY
HF1500-2U
21002100
21002500
22002698
30503100
25002800
4200
400
HF2000-2U
23002100
23002700
24002898
32503300
25002800
4800
400
Model
HF2500-2U
Speed
(m/min)
20 / 30 / 45
Car
Hoistway
Type
Standard
Type
(Unit : mm)
Car
Clear
Opening
OP
Internal
CACB
External
AB
XY
MXMY
A2000-2U
2350
23505300
24505350
33005800
33005800
17500
12000
A2500-2U
2750
27506300
28506350
37006800
38506800
22500
12500
12000
Model
Speed
(m/min)
Hoistway
M/C Room
Hitch Beam
Reaction (kg)
R1
R2
25002100
25003000
26003198
34503600
25002800
5400
400
A2000-3U
2350
23505300
24505350
33005800
33005800
17500
HF3000-2U
27002300
27003300
28003498
36503900
25002800
6000
450
A2500-3U
2750
27506300
28506350
37006800
38506800
22500
12500
HF3500-2U
28002500
28003800
29003998
40004450
28003200
7900
750
A2000-2UD
2350
23505300
24505300
33005800
33005800
17500
12000
30002800
30004500
31004758
42005250
28004200
8800
900
A2500-2UD
2750
27506300
28506300
37006800
38506800
22500
12500
32003000
32005000
33005258
44005750
28004200
10500
1050
A2000-3UD
2350
23505300
24505300
33005800
33005800
17500
12000
A2500-3UD
2750
27506300
28506300
37006800
38506800
22500
12500
HF4000-3U
HF5000-3U
20 / 30
Notes : 1. Please consult Hyundai when the loading capacity is over 5000kg or the car is non-standard size.
2. The loading capacity should be over 250kg/m2 minimally.
3. The actual reaction may slightly differ from above dimensions in line with machine beam position.
4. Above dimensions are based on up-sliding door available for 2-panel side-opening (2S) doors of same capacity.
22
M/C Room
Hitch Beam
Reaction (kg)
R1
R2
Double
Entrance
Type
30 / 45
Notes : 1. The car external size can be varied in line with entrance type.
2. When non-standard capacities and dimensions are required, consult Hyundai.
3. The car door is applied in BS code region.
23
Standard/Optional
Section of Hoistway
Entrance
MX
30
M/C Room
Height (MH)
700
Concrete Opening
OP+140
B1600-2S30, 45
B1600-2S60
B1750-2S30~60
B1350-2SD30, 45
Double
Entrance
Type
B1350-2SD60
B1600-2SD30, 45
B1600-2SD60
B1750-2SD30~60
Internal
CACB
External
AB
1100
13002300
14002507
XY
MXMY
21002850
23003500
15002300
16002507
23002850
27504000
1200
16002300
17002507
24002850
28504000
1100
13002300
14002634
23003000
23003500
1200
15002300
16002634
25003000
27504000
16002300
17002634
26003000
Hitch Beam
Reaction (kg)
R1
R2
10500
11500
700
700
1000
500
700
Transom Panel
Hall Position
Indicator
9500
8500
11500
9500
Emergency
Call Switch
8500
10500
(For emergency
call, only rescue
floor is applied)
HB
(By others)
150
80
30
Clear
Opening (OP)
Concrete Opening
OP+300
Concrete Opening
OP+300
28504000
Notes : 1. When non-standard capacities and dimensions are required, consult Hyundai.
2. Above dimension are applied in case the door is standard. In case fire protection door is applied, hoistway size for 1 car should be applied above X dimension plus 100mm.
3. Consult Hyundai in case the code applied.
24
700
700
M/C Room
1200
1200
Hoistway
1900
B1350-2S60
Car
Clear
Opening
OP
1000
B1350-2S30, 45
(Unit : mm)
700
Model
30
(By others)
80
700
2100
700
5000
Concrete Opening:JH+50
105
2400
250
1800
EA
Concrete Opening
OP+300
1650
4800
1000
90
96
300
1500
1000
4600
Concrete Opening
OP+300
700
60
Finished
Floor Level
(By others)
(By others)
700
1200
96EA
700
4400
Clear
Opening (OP)
Concrete Opening:JH+50
30/45
30
Pit
(PP)
Waterproof Finish
(By others)
Overhead
(OH)
Ladder
(By others)
HB With HPI
700
Receptacle
(By others)
(Unit : mm)
Speed
(m/min)
(By others)
Distribution Board
(By others)
Standard
Type
30
Control
Panel
Type
80
OP
(By others)
700
96EA
1050
500
Concrete Opening
OP+140
700
700
1000
700
(By others)
Finished
Floor Level
(By others)
MY
CA
Clear
Opening (OP)
R2
30
HB With HPI
(By others)
150
700
Cinder Concrete
Min. 150
(By others)
Overhead (OH)
CB
R1
25
Entrance Design
30
Entrance Design
500
700
250
Indicator lamp
150
50
Hall Button
with Indicator
150
Concrete Opening
Clear Opening
+ CP + 100
2
EH+100
500
500
Concrete Opening
500
500
1100
Entrance Height(EH)
500
30
1000
700
CP
(*)
UP
700
Hall Button
with Indicator
Clear Opening
+ 100
2
Clear Opening (OP)
Finished
Floor Level
(By others)
D
- OF CAR
Transom Panel
Plan of Entrance
Section of Entrance
700
100
200
Position
Indicator
300
30
Finished
Floor Level
(By others)
Concrete Opening
Clear Opening
+ CP + 100
2
200
100
100
Clear
Clear
Opening
Opening
ClearOpening
Opening
Clear
Opening
Clear
Opening
Clear
Opening
+100
222222
(*)
Hall Button
with Indicator
150
1000
700
CP
700
Hall Button
Plan of Entrance
(Unit : mm)
Persons
Speed(m/min)
Width of
Control Panel(CP)(*)
8~17
Under 105
60
90
105
530
530
630
630
20, 24
26
200
27
Section Entrance
Plan of Entrance
Section of Entrance
(150)
Clear Opening (OP)
HB With HPI
Hall Button
70
150
150
100
50
130
Jamb
Width
JambWidth
Width
Jamb
Jamb
Jamb
Width
Width
50
(180)
Clear Opening (OP)
70
JP050 Type
Wall Finish
Thickness
Wall
Thickness
Jamb Width
90
JP050 Type
30
70
145
30
70
Jamb Width
Wall Finish
Thickness
30
100
Wall
Thickness
Jamb Width
50
90
130
Plan of Entrance
150
Hall
Button
150
130
90
Note : The above layout is for left side opening. Right side opening doors are available, if requested.
JP050 Type
50
50
50
50
50
50
JP050 Type
Ceiling Line
100
90
(130)
Building Structure
(By Other Contractors)
90
(130)
130
28
Jamb Width
50
50
130
Building Structure
(By Other Contractors)
130
JP100 Type
Jamb Width
50
50
90
(130)
Jamb Width
Jamb Width
10
50
Jamb Width
Ceiling
Line
10
Ceiling Height
Upper
Frame
10
50
10
100
Upper
Frame
JP200 Type
JP200 Type
JP100 Type
JP200 Type
JP200 Type
29
NW-BT, NW-BB
NW-BT, NW-BB
1.732H
(note 2) B
(note 1) Floor Opening AA
2230
50
1.428H
(note 3) 2650
1910
50
Working
Point
Qty of
Flat Step
NW-BT
NW-BB
2
3
2560
2967
2230
2637
1820
2227
1490
1897
2511
2918
2118
2525
4500
4910
612
855
1150
1100
1250
813
1056
1350
1300
1450
1014
1257
1550
1500
1650
Rise H (mm)
90
R2
R3
L20020020
R4
50 50
w3
w2
w1
150
NW1000
R4
Type
NW1200
Rise H (mm)
Number of
Intermediate Support
Floor Opening
Enclosure
(By Others)
Min. 200
Type
Rise H (mm)
R1
R2
R3
Number of
Intermediate Support
R1
L20020020
50 50
R2
w4
w5
R3
R4
NW800
Min. 200
1070
793
950
968
Floor Opening
Enclosure
(By Others)
L20020020
Type
NW800
W1
W2
W3
(Unit : mm)
NW1000
NW1200
612
813
1014
855
1056
1257
1150
1350
1550
W4
1100
1300
1500
W5
1250
1450
1650
50 50
w4
Type
Section Dimensions
w3
w2
w1
(Unit : kg)
935
W1
W2
W3
W4
W5
90
NW1200
W5
Min. 200
90
NW1000
11(Shim)
NW800
R1
11(Shim)
Type
Number of
Intermediate Support
Min. 4500
(Unit : mm)
Reactions
Min. 200
11 (Shim)
150
Model
(Inclination)
Section Dimensions
11(Shim)
Working
Point
2358
30
1070
R2
L2
Reinforced Plate
(By Others)
Wiring Inlet
(By Others)
35
L1
L3
R1
(note 3) 2522
Intermediate
Support
(By Others)
Working
Point
H = Rise
1490
937
1070
Min. 1170
Min. 1170
937
R3
30
Soffit Guard
(By Others)
HEAD ROOM
Min. 2300
793
950
R4
50
Wiring Inlet
(By Others)
(note 2) F
R2
R1
H = Rise
Working
Point
908
Head ROOM
Min. 2300
Soffit Guard
(By Others)
1070
50
L20020020
50 50
Reactions
Vertical Rise
Reactions
H(mm)
3000
~6000
(Unit : kg)
ML800
ML1000
ML1200
R1
R2
Reinforced Plate
(By Others)
31
MILLENNIUM ESCALATORS(30
)
ML-BT, ML-BB
ML-BT, ML-BB
(note 2) B
1.732H
(note 3) 2367
1.428H
2088
50
Floor Opening Enclosures (By Others)
1777
50
Model
Qty of Vertical Rise H Speed B
(Inclination) Flat Step
(mm)
1490
1897
1967
1966
2372
2116
2523
2707
3306
3712
2250
2657
2777
2727
3133
4230
4640
4750
4720
5120
Section Dimensions
Base Plate
15019
ML1200
813
1056
1349
1299
1449
1014
1257
1550
1500
1650
Rise H (mm)
R4
Type
ML1200
936
90
R2
R3
Reinforced Plate
(By Others)
32
w4
W5
Rise H (mm)
Number of
Intermediate Support
R1
R2
R3
R4
Min. 200
H 6000
1000
793
950
968
Section Dimensions
Floor Opening
Enclosure
(By Others)
ML800
ML1000
R1
L20020020
(Unit : kg)
Type
R3
Number of
Intermediate Support
50 50
R4
R2
w3
w2
w1
5000 H 7600
7600 H 10500
1
1
2
0.66H + 2600 0.37L1 + 900
0.37L1 + 1200
0.37L1 + 1250
0.66H + 2000 0.37L2 + 350
0.37L2 + 500
0.37L2 + 450
0.37(L1 + L2) + 600 0.37(L1 + L2) + 850 0.37(L2 + L3) + 400
0.37(L1 + L3) + 700
R1
Floor Opening
Enclosure
(By Others)
Min. 200
11(Shim)
ML1000
594
837
1130
1080
1230
Number of
Intermediate Support
w3
w2
w1
Min. 150
ML800
W1
W2
W3
W4
W5
Rise H (mm)
50 50
Type
Type
(Unit : mm)
Reactions
L20020020
Min. 4000
936
90
Min. 150
11 (Shim)
Min. 200
2316
L20020020
Base Plate
15019
Type
ML800
W1
W2
(Unit : mm)
ML1000
ML1200
612
813
1014
855
1056
1257
W3
1148
1349
1550
W4
1098
1299
1500
W5
1248
1449
1650
50 50
w4
w5
Vertical Rise
H(mm)
Reactions
Min. 200
3000
~6000
Reactions
(Unit : kg)
ML800
ML1000
ML1200
R1
R2
90
Working
Point
90
H 6000
D
1695
2102
2237
2236
2642
11(Shim)
C
2080
2487
2606
2556
2962
Min. 150
2286
30 2693
2876
3476
30 ~ 40
3882
11(Shim)
ML-BT
ML-BB
(30)
H 6000
6000H 7600
7600H 10500
Min. 150
2
Notes : 1. AA = 1.732H + B + C + 100
2. In case inverter system is applied, B, F shall increase 500mm.
(800Type, 1000Type : increase 700mm)
3. When vertical rise is over 6000mm, 3-flat step is applied.
4. Dimension between the end of handrail to the wall ; Min. 2500mm
5. If EN115 is applied, consult Hyundai.
6. Vertical Rise H 10.5m.
Wiring Inlet
(By Others)
(note 3) 2139
H = Rise
R2
J
L2
R1
35
L1
L3
1000
Working
Point
Working
Point
Intermediate
Support
(By Others)
1498
937
1000
Min. 1100
R2
Min. 1100
937
R3
30
Soffit Guard
(By Others)
Min. 2100
793
950
50
Wiring Inlet
(By Others)
(note 2) F
R4
R1
H = Rise
Working
Point
908
Head Room
Min. 2300
Soffit Guard
(By Others)
1000
50
Reinforced Plate
(By Others)
33
H-SERIES ESCALATORS
H-SERIES ESCALATORS
HA-BT, HA-BB
HD-BT, HD-BB
Working
Point
H = Rise
0
110
908
Min. 290
793
(note 3) 4342
R4
Wiring Inlet
(By Others)
0
100
Wiring Inlet
(By Others)
Intermediate Support
(By Other)
2241
1300
Working
Point
L3
R1
"B"
"B"
937
(note 1)
Intermediate
Support
(By Others)
843
Min. 2300
(note 5) H = Rise
R1
1280
937
"A"
1400
Working
Point
Min. 2300
Min. 1400
1200
50
2657
"A"
L1
"B"
30
R2
30
937
R3
(note 3) 4014
Head Room
Soffit Guard
(By Others)
2150
1.732H
2884
50
50
937
1.732H
1210
2943
50
Working
Point
R2
R3
R4
R5
Min. 5100
3065
L 2 (Max.12000)
L 3 (Max.12000)
L 4 (Max.12000)
L 1 (Max.12000)
Min. 5700
L2
w4
w 4 + 200
90
11(Shim)
Min. 210
L20020020
Reinforced Plate
(By Others)
W1
594
813
1014
W2
986
1205
1406
W3
1330
1549
1750
W4
1280
1499
1700
W5
1430
1650
1850
Min. 200
90
HA1200
11 (Shim)
HA1000
Min. 210
HA800
L20020020
Base Plate
15019
Section Dimensions
Type
HD800
(Unit : mm)
HD1000
HD1200
W1
612
813
1014
W2
965
1164
1364
W3
1301
1500
1700
W4
1251
1450
1650
W5
1451
1650
1850
50 50
Reactions
Type
Min. 200
50 50
34
Type
w5
w3
w2
w1
HA800
(Unit : kg)
HA1000
HA1200
Vertical Rise
H (mm)
R1
0.47L1 + 1200
0.51L1 + 1400
0.54L1 + 1700
R2
0.47L2 + 400
0.51L2 + 500
0.54L2 + 600
10500 H 15000
R3
R4
Min. 200
90
50 50
Floor Opening
Enclosure
(By Others)
(Unit : mm)
11 (Shim)
90
L20020020
Base Plate
15019
936
Min. 200
11(Shim)
Min. 210
Section Dimensions
Min. 210
w5
w3
w2
w1
L20020020
50 50
Reinforced Plate
(By Others)
w4
w5
35
MODULAR ESCALATORS
MOVING WALKS
M-BB
HORIZONTAL TYPENPM-BT
5FOTJPOTUBUJPO
%SJWFTUBUJPO
50
(note 3) 3698
1073
Wiring Inlet
(By Others)
H=Rise
0
106
803
1073
1100
L 3 ~L (n-1) (Max.8000)
L n (Max.8000)
L 1 (Max.7000)
Reactions
L20020020
Type
M800
W1
594
1014
W2
W3
895
1275
1695
W4
1244
1664
W5
1375
1795
1342
90
Rn (kg)
330 (Ln -1 + Ln)
NPM1200
420 L + 1700
420 L2 + 700
w5
w3
w2
w1
Min. 200
Section Dimensions
(Unit : mm)
Type
NPM1000
NPM1200
W1
814
1014
W2
1057
1257
W3
1350
1550
W4
1300
1500
W5
1500
1700
w4
w5
(Unit : kg)
M1200
Min. 200
L20020020
L20020020
50 50
R4 (kg)
320 (L3 + L4)
L20020020
Min. 150
M800
Reinforced Plate
(By Others)
R3 (kg)
330 (L2 + L3)
50 50
Reactions
Min. 200
R2 (kg)
400 L2 + 400
Base Plate
15019
w4
w 4 + 200
R1 (kg)
400 L1 + 1300
(Unit : mm)
M1200
Type
NPM1000
90
Floor Opening
Enclosure
(By Others)
9110~80000
11(Shim)
Section Dimensions
(L1 ~ Ln : m)
11 (Shim)
933
90
Min. 150
11(Shim)
Min. 200
11(Shim)
R1
Notes : 1. In case inverter system is applied, dim. 2190, 4000 shall increase 500mm.
(1000Type : increase 700mm)
2. Dimension between the end of handrail to the wall : Min. 2500mm
3. Dimensions are based on EN115.
Min. 150
w5
w3
w2
w1
50 50
Min. 150
Rn
L 2 (Max.7000)
36
Working
Point
90
933
Min. 1173
R1
Working
Point
Min. 5000
Base Plate
15019
R4~R(n-1)
"B"
Min. 3000
(note 1)
Intermediate
Support
(By Others)
400R
2967
"B"
(note 3) 3427
699
Min. 2300
Working
Point
30
R2
"B"
Working
Point
R2
R3
2074
"A"
1200
1200
660
719
"A"
937
660
937
2763
Soffit Guard
(By Others)
50
(note 1) 2190
50
1100
1.732H
2709
50
50 50
Reinforced Plate
(By Others)
37
MOVING WALKS
The following works are not included in the elevator contract, and shall be done by other contractors
in accordance with the Hyundai Elevator's drawings and the applicable codes and regulations.
The reference rules shown are from Code ANSI.
1787
4.70465H
(note 1) 3300
50
2643
Head Room
790
719
R1
"B"
Wiring Inlet
(By Others)
Hoistway
1. Clear, plumb hoistway with fire resistant hatch walls as required by the applicable
1. Light outlet for each elevator, in center of hoistway (or in machine room) as
Working
Point
R3
R4
L 2 (Max.10000)
L 3 (Max.10000)
Maximum allowable vertical spacing of rail supports without backing. (Rule 200.4
L 1 (Max.10000)
Reactions
(L1 ~ Ln Unit : m)
NPM1000
10
&
12
1430
~
7000
R3 (kg
R2 (kg)
R3 (kg)
7. Dry pit reinforced to sustain normal vertical forces from rails and buffers. (Rule
106.1b and 109) Consult Hyundai Elevator Company for rail forces and buffer
NPM1200
R1 (kg)
R4 (kg)
R5 (kg)
R4 (kg)
R5 (kg)
453 L1 + 700 439 L2 + 45 440 (L2 + L3) 440 (L3 + L4) 449 (L1 + L4) 503 L1 + 780 487 L2 + 50 489 (L2 + L3) 489 (L3 + L4) 498 (L1 + L4)
impacts. Where there is space below the pit floor that can be occupied, consult
Hyundai Elevator Company for special requirements. (Rule 300.4) Cylinder hole,
casings under the pit as required, and backfilling around the cylinder casings when
direct plunger type is to be installed.
ladder extending 1060mm minimum above sill of access door. (Rule 106.1d)
and sills are in place. Door frames are to be anchored to walls and properly
90
Min. 150
11(Shim)
L20020020
Base Plate
15019
Section Dimensions
(Unit : mm)
Type
NPM1000
NPM1200
W1
814
1014
W2
1057
1257
W3
1350
1550
W4
1300
1500
W5
1500
1700
Emergency Provisions
9. Elevator firemans and other emergency services wiring and interconnections to
automatic sprinkler systems or heat and smoke sensing devices furnished by
others and installed to terminal points on the elevator controllers.
10. When emergency power operation of elevators is required, the electrical
contractor should coordinate with Hyundai Elevator Company or local distributor
for operation requirements.
Machine Room
11. Enclosed and protected machine room. (Rule 101.1)
12. Access to the machine room and machinery space as required by the applicable
50 50
8. Where access to the pit is by means of the lowest hoistway entrance, vertical iron
9. Entrance walls and finished floor are not to be constructed until after door frames
w5
w3
w2
w1
Machine Room
required.
R2 (kg)
and 301.1) Divider beams 100mm between hoistway at each floor and roof, for
R1 (kg)
4. Supports for rail brackets at each floor, roof, and machine room. (Rule 200.9)
Notes : 1. In case inverter system is applied, dim. 3300 shall increase 500mm.
(1000Type : increase 700mm)
2. Dimension between the end of handrail to the wall : Min. 2500mm
3. Dimensions are based on EN115.
Number of
Incli- Vertical intermediate
nation H Rise
(mm) Support
Electrical Work
Hoistway
code. (Rule 100.1a)
Intermediate Support
(By Others)
"B"
12
940
"A"
1100
1200
Working
Point
Min. 2300
Height (H)
1129
Building Work
1100
"A"
940
11. Elevator firemans and other emergency service requirements may differ from
each country. Consult Hyundai Elevator Company or local distributor for other
local requirements.
12. When provisions for earthquake protection are required, consult Hyundai Elevator
Company for special requirements.
13. Reinforced concrete machine room floor slab or grating, as specified, which must
not be placed over the hoistway until elevator machinery is set in position. (Rule
90
Clear access above ceiling or trench in floor, for oil line and wiring duct from
machine room, if machine room is remote from elevator hoistway. (For Hydraulic
11(Shim)
Min. 150
w4
w5
Q (Kcal/H) = WVFN
Elevator) Cutout through machine room wall, for oil line and wiring duct as
W : Capacity (kg)
V : Speed (m/min)
N : Number of cars
14. Hoisting beams, trap doors, and other means of access to machine room for
L20020020
50 50
Reinforced Plate
(By Others)
38
39
Persons / Kg
6 / 450
8 / 550
9 / 600
10 / 700
11 / 750
13 / 900
15 / 1000
17 / 1150
20 / 1350
24 / 1600
MCCB (A)
Cable (mm2)
Earth (mm2)
Motor
(kW)
1Car
2Cars
1Car
2Cars
1Car
2Cars
1Car
2Cars
60
5.5 (2.8)
20 (20)
30 (20)
4 (3)
7 (5)
4 (4)
6 (4)
4 (6)
4 (6)
90
7.5 (4.2)
20 (20)
30 (40)
6 (4)
10 (8)
4 (4)
6 (10)
4 (6)
6 (6)
105
7.5 (4.9)
20 (20)
40 (40)
7 (5)
12 (9)
4 (4)
10 (10)
4 (6)
6 (6)
60
5.5 (3.4)
20 (20)
30 (20)
5 (4)
9 (6)
4 (4)
6 (4)
4 (6)
4 (6)
4 (6)
90
7.5 (5.1)
20 (20)
30 (40)
7 (5)
13 (10)
4 (4)
6 (10)
4 (6)
105
11 (5.9)
30 (20)
50 (40)
8 (6)
15 (11)
6 (4)
16 (10)
4 (6)
6 (6)
60
5.5 (3.7)
20 (20)
30 (30)
5 (4)
9(7)
4 (4)
6 (6)
4 (6)
4 (6)
90
11 (5.6)
30 (20)
50 (40)
8 (6)
14 (11)
6 (4)
16 (10)
4 (6)
6 (10)
105
11 (6.5)
30 (20)
50 (40)
9 (7)
16 (12)
6 (4)
16 (10)
4 (6)
6 (10)
6 (6)
60
7.5 (4.3)
20 (20)
40 (30)
6 (5)
11 (8)
4 (4)
10 (6)
4 (6)
90
11 (6.5)
30 (20)
50 (40)
9 (7)
16 (12)
6 (4)
16 (10)
4 (6)
6 (6)
105
11 (7.6)
30 (20)
60 (40)
11 (9)
19 (14)
6 (4)
16 (10)
4 (6)
10 (6)
60
7.5 (4.6)
20 (20)
40 (30)
6 (5)
12 (9)
4 (4)
10 (6)
4 (6)
6 (6)
90
11 (6.9)
30 (20)
50 (40)
10 (7)
17 (13)
6 (4)
16 (10)
4 (6)
6 (10)
105
11 (8.1)
30 (30)
60 (50)
11 (9)
20 (15)
10 (6)
16 (16)
4 (6)
10 (10)
120
(9.2)
(30)
(50)
(10)
(18)
(6)
(16)
(6)
(10)
60
11 (5.6)
30 (20)
50 (30)
8 (6)
14 (11)
6 (4)
10 (6)
4 (6)
6 (6)
90
15 (8.3)
40 (30)
60 (50)
12 (9)
21 (16)
10 (6)
16 (16)
6 (6)
10 (10)
105
15 (9.7)
40 (30)
75 (50)
14 (10)
24 (18)
10 (6)
25 (16)
6 (6)
10 (10)
120
(11.1)
(30)
(60)
(12)
(21)
(6)
(16)
(6)
(10)
150
(13.8)
(50)
(100)
(15)
(28)
(10)
(25)
(6)
(16)
60
11 (6.2)
30 (20)
50 (40)
9 (7)
15 (12)
6 (4)
16 (10)
4 (6)
6 (10)
90
15 (9.2)
40 (30)
75 (50)
13 (10)
23 (18)
10 (6)
25 (16)
6 (6)
10 (10)
105
15 (10.8)
40 (30)
75 (60)
15 (11)
27 (20)
10 (6)
25 (16)
6 (6)
10 (10)
120
(12.3)
(40)
(75)
(13)
(23)
(10)
(25)
(6)
(16)
150
(15.4)
(50)
(100)
(17)
(31)
(10)
(25)
(6)
(16)
60
11 (7.1)
30 (20)
50 (40)
10 (8)
18 (13)
6 (4)
16 (10)
4 (6)
6 (10)
90
15 (10.6)
40 (30)
75 (60)
15 (11)
27 (20)
10 (6)
25 (16)
6 (6)
10 (10)
105
18.5 (12.4)
50 (30)
100 (60)
17 (13)
31 (23)
16 (6)
35 (16)
6 (6)
10 (16)
120
(14.1)
(40)
(75)
(15)
(27)
(10)
(25)
(6)
(16)
150
(17.7)
(60)
(100)
(20)
(35)
(10)
(25)
(6)
(16)
60
15 (8.3)
30 (20)
60 (40)
12 (9)
21 (16)
10 (4)
16 (10)
6 (6)
6 (6)
90
18.5 (12.5)
50 (40)
100 (75)
17 (13)
31 (24)
16 (10)
25 (25)
6 (6)
10 (10)
105
22 (14.5)
50 (40)
100 (75)
20 (15)
37 (28)
16 (10)
35 (25)
6 (6)
10 (10)
120
(16.6)
(40)
(100)
(17)
(31)
(10)
(25)
(6)
(10)
150
(20.7)
(75)
(125)
(23)
(41)
(16)
(35)
(10)
(25)
60
15 (9.9)
40 (30)
75 (50)
14 (10)
25 (19)
10 (6)
25 (16)
6 (6)
10 (6)
90
22 (14.8)
50 (50)
100 (75)
21 (16)
37 (28)
16 (10)
35 (25)
6 (6)
10 (10)
105
22 (17.2)
60 (50)
125 (100)
24 (18)
43 (33)
16 (16)
35 (25)
10 (6)
16 (10)
120
(19.7)
(50)
(100)
(21)
(37)
(16)
(25)
(6)
(10)
150
(24.5)
(75)
(150)
(27)
(49)
(16)
(50)
(10)
(35)
Notes : 1. Above power feeder sizes are for the length of electric wire up to 50m from
elevator machine room to power.
For the length being 50m or more, the following formular should be applied.
2. Above cable sizes are for copper wires inside electrometallic tubings.
Cable length (m)
Size in the above (mm2)
Cable sizes (mm 2) =
50
3. For power requirement of 3 cars or more, consult Hyundai.
40
Power (KVA)
Speed
(m/min)
4. Machine room temperature should be maintained below 40C with ventilating fan
and air conditioner, and humidity below 90%.
5. Data shown in ( ) is applied to the Machine-Room-Less elevators and gearless elevators.
AC-Gearless180~600m/min
N.F.B. Rated Transformer
Speed
Persons
Motor Current (A) Capacity (kVA)
(m/
/ kg
(kW)
min)
1Car 2Cars 1Car 2Cars
13 /
180 16.6
50
100
18
33
900
180 18.4
60
100
20
37
15 /
210
23
75
125
26
46
1000
240
26
100 150
29
52
180 21.2
75
125
24
42
210
25
75
150
28
50
240
30
100 175
33
60
300
36
125 200
40
72
17 /
360
43
125 200
48
86
1150
420
50
125 225
56
100
480
57
150 300
63
114
540
64
175 300
71
128
600
71
175 350
79
142
(50/60Hz, 380V)
Power Feeder
(mm2)
Earth Wire
(mm2)
1Car
2Cars
1Car
2Cars
10
25
16
10
16
25
16
16
25
35
35
35
50
50
50
25
35
50
35
50
50
70
70
70
120
120
150
6
10
16
10
10
16
25
25
25
35
35
35
16
25
35
25
35
35
50
50
50
95
95
120
Notes : 1. The above power sizes are for lengths of electric wire up to 50m from the elevator
machine room to the transformer.
For lengths of 50m or more, the following formula should be applied :
Power feeder length (m)
size in the above (mm2)
Power feeder size (mm2) =
50
1.00
0.91
0.85
0.80
0.76
Power Feeder
(mm2)
1Car
16
25
35
35
50
50
50
70
70
25
35
35
50
50
50
70
70
95
2Cars
50
50
70
70
120
120
120
150
185
50
70
70
120
150
150
150
185
240
6 / 450
8 / 550
9 / 600
10 / 680
11 / 750
13 / 900
15 / 1000
17 / 1150
20 / 1350
24 / 1600
Speed
(m/min)
Motor (kW)
30
45
30
45
30
45
30
45
30
45
30
45
30
45
30
45
30
45
30
45
15
22
18.5
30
18.5
30
18.5
30
18.5
30
30
37
30
37
37
52
37
52
37
52
1Car
10
16
25
25
35
35
35
50
70
16
25
25
35
35
35
50
70
95
2Cars
35
35
50
50
95
95
95
120
150
35
50
50
95
120
120
120
150
185
2. Above power feeder sizes are for copper wires inside electro-metallic tubing.
3. It is recommended a larger diameter earth wire be used.
4. For installing several elevators, apply the following formula.
Transformer Capacity (kVA) = Number of elevator X Diversity factor
5. Consult Hyundai if you need electric power requirements for 220V.
6. For AC-Geared elevators, consult Hyundai.
7. For AC-Gearless elevators(300m/min ~ 1080m/min), consult Hyundai.
Hydraulic30~45m/min
Persons / kg
Earth Wire
(mm2)
(50/60Hz, 380v)
N.F.B. Rated
Current (A)
Transformer
Capacity (kVA)
Power Feeder
(mm2)
1Car
2Cars
1Car
2Cars
1Car
2Cars
1Car
2Cars
1Car
2Cars
1Cars
2Cars
50
75
75
100
75
100
75
100
75
100
100
125
100
125
125
175
125
175
125
175
100
150
125
175
125
175
125
175
125
175
175
225
175
225
225
300
225
300
225
300
25
38
30
49
30
49
30
49
30
49
49
62
49
62
62
81
62
81
62
81
45
70
56
90
56
90
56
90
56
90
90
113
90
113
113
148
113
148
113
148
10
16
16
25
16
25
16
25
16
25
25
35
25
35
35
50
35
50
35
50
25
50
35
70
35
70
35
70
35
70
70
95
70
95
95
150
95
150
95
150
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
10
6
10
6
10
6
10
6
10
6
10
6
10
6
10
10
10
10
16
16
25
16
25
16
25
3000
3900
3500
5500
3500
5500
3500
5500
3500
5500
5500
6900
5500
6900
6900
9700
6900
9700
6900
9700
6000
7800
7000
11000
7000
11000
7000
11000
7000
11000
11000
13800
11000
13800
13800
19400
13800
19400
13800
19400
1000
1300
1100
1900
1100
1900
1100
1900
1100
1900
1900
2300
1900
2300
2300
3500
2300
3500
2300
3500
2000
2600
2200
3800
2200
3800
2200
3800
2200
3800
3800
4600
3800
4600
4600
7000
4600
7000
4600
7000
Earth Wire
(mm2)
Ventilation of
Machine Room (m2/h)
Notes : 1. Above power feeder sizes are for the length of electric wire up to 50m from elevator machine room to transformer.
For the length being 50m or more, the following formular should be applied:
2. Above power feeder sizes are for copper wires inside electrometallic tubings. Power feeder sizes (mm2) = Power feeder length (m) Size in the above (mm2)
50
3. For power requirement of 3 cars or more, consult Hyundai.
4. Machine room temperature should be maintained below 40C with ventilating fan and air conditioner, and humidity below 90%.
5. The heat emission and ventilation of machine room on above dimensions may vary slightly with the machine room size and
peripheral environment.
6. Consult Hyundai if you need electric power requirements for 220V.
41
New World
Class
/
Millennium
/
Modular
Motor
(kW)
5.5
12
7.5
14
5.52/11
19
7.52
27
7.53
40
7.54
52
7.55
65
7.56
78
11
19
16
25
18.5
31
22
36
26
46
30
52
37
60
H-Series
C.B. Rated
Current (A)
20m
40m
60m
80m
100m
120m
50
30
30
60
40
30
75
50
40
125
75
60
175
100
100
225
150
125
300
175
150
350
200
175
100
50
40
125
60
50
150
75
75
175
100
75
175
125
100
200
125
100
300
150
125
10
6
6
10
6
6
16
6
6
25
6
6
35
10
6
35
16
10
50
16
16
50
25
16
16
6
6
25
6
6
25
10
6
25
10
6
35
16
6
35
16
10
50
16
16
16
6
6
25
6
6
25
10
6
35
16
10
50
25
16
95
25
25
95
35
25
120
35
25
25
10
6
35
16
10
35
16
16
50
16
16
50
25
16
95
25
25
95
35
25
25
10
6
35
10
6
35
16
10
50
25
16
50
35
25
120
35
25
120
50
35
150
50
35
35
16
10
50
25
16
50
25
16
95
25
25
95
35
25
120
35
25
120
50
35
35
16
10
35
16
10
35
25
16
95
25
25
120
35
25
120
50
35
185
70
35
185
95
50
50
25
16
70
25
16
95
35
25
120
35
25
120
35
25
120
50
35
185
70
35
35
16
10
50
16
16
50
25
16
95
35
25
120
50
35
185
70
35
185
95
50
240
95
70
50
25
16
95
35
25
120
35
25
120
35
35
120
50
35
185
70
35
185
95
50
35
16
16
50
25
16
70
25
25
120
35
25
150
50
35
185
95
50
240
95
70
300
120
95
95
25
25
120
35
25
120
35
35
150
50
35
150
50
35
185
95
50
240
95
70
Lighting Power
Balustrade Vertical Power Supply Power Supply C.B. Rated
Voltage
Type
Rise (m) Capacity (kVA) (AC-1phase) Current (A)
1.83-4.27
With Handrail 4.28-7.6
Lighting
(BTL Type) 1.83-4.27
4.28-7.6
Without Handrail
Lighting
1.4(3)
2(6)
1.4(3)
2(6)
1.2
100-110
200-265
100-110
200-265
30(40)
40(70)
20
20(40)
20
42
20m
6
6
10
16
10
4
4
2.5
16
6
4
2.5
25
10
10
6
6
4
10
10
3, 200V, 50Hz
3, 220V, 60Hz
3, 346V, 50Hz
3, 380V, 60Hz
3, 415V, 50Hz
3, 460V, 60Hz