Hyper Frame System

Steel
-rigid connections
Steel structure
structure with
with semi
semi-rigid
connections

Nippon Steel Corporation

HyperFrameSystem
Diaphragm

Welding

High tension bolts

Conventional method

Blind bolt

Split-tee

High tension bolts

HFSSplit-tee joint

HyperFrameSystem
HFS

Conventional method

Column
CuttingGroove
Diaphragm
Blind bolt

HTB-F10T
Splice plate

SHTB

Split-tee

Welding

Hole
CuttingGrooveScallop

Characteristics
Special quality control is
unnecessary .
High and stable quality of Joints
Cuttings and welding of square-shaped steel
pipe are unnecessary.
Reduce labor of
steel frame fabrication
Because there is no bracket,
transportation efficiency is obtained

Simplification of joint design


Standardization of joint details

Blind bolt of torque control type


Pin-tail

Nut

Second sleeve

Shar-washer
Washer

First sleeve

Bolt

Inserted bolt

Buckling of sleeve

Finish Cutting of pin-tail

Applications of HFS
Member of applications
Member

Material

Size

Column

Cold forming columns


BCR295

-25012-40022

beam

Hot rolled H-steels


SN400B

H-2501256/9 H-48830011/18
H-4002009/12 H-6002009/19

Joint parts
Joint parts

Material

Split-tee

Hot rolled CT-steelsSN490

HTB for tension type joint

Blind bolts of torque control typeTCBB

HTB for friction joint

High tension bolts of torque control typeS10T


Ultra-high strength boltsSHTB

Designs of HFS
Design flow
Stress calculation of frame, design of section

Selection of the standard joint

Calculation of slope by relative story displacement

Characteristics
- Strength of column/Strength of beam
Column-beam joint is rigid
- The size table

- column-beam joint is semi-rigid

Joint yielding case

Beam yielding case


Confirmation of width-thickness ratio,
stiffness distribution factor,
and eccentric factor

Confirmation of
ultimate horizontal resistant force

END

END

Lateral strength of column's skin plate

Column-beam joint of HFS

Lateral deformation

Yield line

Coefficient of column-beam joint


1
1
1
=
+
LK
cK
tK

Lateral deformation of column's skin plate


P/2

of column-beam joint
cKLateral coefficient of column
tKCoefficient of split-tee

P/2

LKCoefficient

Y1

Y1

t
Deformation of split-tee

X
H
Y

Confirmation of slope by relative story displacement


beam

column

Coefficient of
column-beam joint

Reduced construction period


0
Basic design

1.0

2.0

4.0

month

Working design

Conventional

(0.5)

(0.5)

Manufacturing
drawings of steel

(1.0)
Preparations of steel member
(1.5)
Steel Work
Application for building
confirmation
(1.5)
Basic design

(1.5)
Foundation

Election

(1.0)

(1.0)

Working design
(0.5)

HFS

3.0

0.5 month abridgment

Manufacturing
drawings of steel

(0.5)

(0.5)
Preparations of steel member
(1.5)
Steel Work
Application for building
confirmation
(1.5)

(1.0)
Foundation

Election

(1.0)

(1.0)

Applications of HFS

Applications of HFS

Application of HFS