Sie sind auf Seite 1von 10

SECTION 10 14 00

SIGNAGE
1.

PART 1 - GENERAL

1.1.

SECTION INCLUDES

1.2.

1.3.

1.1.1.

Permanent room or space identification signage

1.1.2.

Directional and Informational Signage, site, exterior and interior.

1.1.3.

Safety Signage.

1.1.4.

Vehicle traffic control signage.

1.1.5.

Building identification signage.

1.1.6.

Freestanding Exterior Monument Sign.

1.1.7.

Emergency Evacuation Maps.

REGULATORY REQUIREMENTS
1.2.1.

Comply with signage requirements of the 2009 IBC.

1.2.2.

Comply with accessibility signage requirements of ANSI / ICC A117.1 - American


National Standard for Accessible and Usable Buildings and Facilities; International Code
Council; 2009

1.2.3.

Comply with Manual on Uniform Traffic Control Devices (MUTCD) published by the
Federal Highway Administration (FHWA) for all traffic signage.

SUBMITTALS
1.3.1.

Submit under provisions of Section 01 33 00.

1.3.2.

Shop Drawings:
1.3.2.1.

Indicate sign size, message, and mounting.

1.3.2.2.

Identify mounting location and alignment with adjacent construction and


features.

1.3.3.

Product Data: Provide data on material construction, hardware, and accessories.

1.3.4.

Samples:
1.3.4.1.

Color range: Submit two brochures or other approved submittal of full color
range available for each signage application.

1.3.4.2.

Submit two samples of representative signage illustrating dimensional


characteristics, finish and sheen for Architect selection.

Tule River Justice Center


Tule River Tribal Counsel
NTD # 2013-0023-00

SIGNAGE
10 14 00 - 1

1.3.5.

1.4.

1.3.4.2.1.

Submit samples of representative tactile/braille signage


illustrating letter stroke proportions and braille dot size,
spacing and characteristics.

1.3.4.2.2.

Exterior Monument Sign: Provide sample of cast aluminum


lettering. Provided printed sample illustrating dimensional
and visual characteristics of any logos / emblems / plaques
as indicated in drawings.

Certification:
1.3.5.1.

Certification: Accompanying submittal, provide sign fabricator/manufacturers


written certification stating signs as designed comply with applicable criteria
of IBC, including letter style, spacing and size.

1.3.5.2.

Prior to installation, provide sign fabricator/manufacturers written certification


stating tactile and braille signs comply with specified criteria, including proofreading requirements.

DELIVERY, STORAGE, AND HANDLING


1.4.1.

Deliver products to site. Store and protect under provisions of Section 01 60 00.

2.

PART 2 PRODUCTS

2.1.

MANUFACTURERS
2.1.1.

2.2.

Basis of Design: Characteristics of specific products, where named in this Section, are
indicated to establish required level of quality, appearance, and performance. The
Architect will consider requests for substitutions, under the provisions of Section
01 25 00.

PERMANENT ROOM IDENTIFICATION SIGNAGE (RS)


2.2.1.

Manufacturer: Advance Corporation http://www.advancecorp.com/ (specified as basis of


design) or equal.

2.2.2.

Type: Etched metal signage system.

2.2.3.

Series: Etched Zinc Photocast.

2.2.4.

Material Characteristics: 0.153 inch thick zinc alloy.

2.2.5.

Graphic Image Process: Acid etched process providing raised and Braille relief image.
Applied message not acceptable.

2.2.6.

Sign Size, Design, Style Criteria:


2.2.6.1.

Character size: 5/8 inch minimum, maximum 2 inch height, raised 1/32 inch
above surface.

2.2.6.2.

Character proportion: Provide width to height ratio between 3:5 and 1:1.

2.2.6.3.

Character stroke proportion: Provide stroke width to height ratio between 1:5
and 1:10.

2.2.6.4.

Letter Style: Upper case Helvetica Regular.

Tule River Justice Center


Tule River Tribal Counsel
NTD # 2013-0023-00

SIGNAGE
10 14 00 - 2

2.2.7.

2.2.8.

2.2.9.

2.2.6.5.

Braille criteria: Provide contracted Grade 2 braille, with dots spaced 1/10
inch on center in each cell, and cells spaced 2/10 inch apart, measured from
the second row of dots in the first cell to the first row of dots in the second
cell. Provide dots raised 1/40 inch above surface, with slightly rounded or
eased profile.

2.2.6.6.

Design sign with room number on first line, room name on second, braille
message on third line. Center all copy. Provide minimum 1/2 inch clear
space all around braille image.

2.2.6.7.

Pictogram Criteria: Where pictograms are specified as room identification


signage, provide pictogram centered in minimum 6 inch high space with no
text or braille within this space. Provide tactile and braille message centered
below pictogram.

Sign Message:
2.2.7.1.

RS-1 - Toilet Room Signs: Per detail

2.2.7.2.

RS-2 - Room Signs: Per detail.

2.2.7.3.

RS-3 - Toilet room door symbols: Per detail

Finish/Contrast/Color:
2.2.8.1.

Finish: Provide signs with matte, non-reflective finish, with a maximum 11-19
degree gloss on 60 degree dosimeter.

2.2.8.2.

Contrast: Provide signs with minimum light to dark contrast between


background and message of 70 percent.

2.2.8.3.

Color: Provide signs with two colors as selected by Architect from


manufacturers standard color line.
2.2.8.3.1.

Background: Color 1, selected from very dark color range.

2.2.8.3.2.

Message: Color 2 selected from white or very light color


range.

2.2.8.3.3.

International Symbol of Accessibility: White symbol on


Federal Blue background.

2.2.8.3.4.

Finish System: Mathews acrylic polyurethane coating


system, VOC approved, complying with glare finish criteria.

Mounting:
2.2.9.1.

Exterior: Provide stainless steel spanner head tamper resistant screw in


expansion shields suitable for substrate. Countersink screw flush with
surface.

2.2.9.2.

Interior: Unless noted otherwise, provide double stick foam tape mounting,
1/32 inch thick.

2.2.9.3.

Where signs are mounted on glass panels, install using structural silicone
sealant method specified in this Section.

Tule River Justice Center


Tule River Tribal Counsel
NTD # 2013-0023-00

SIGNAGE
10 14 00 - 3

2.2.9.4.

2.3.

Verify surfaces with irregular or rough finish have been properly finished to
establish flush and lip free installation.

2.2.10.

Fabrication Certification: Prior to installation, provide written certification stating


permanent signage has been proofread by Library of Congress certified readers or
approved alternate.

2.2.11.

At sallyport, staging and holding cell doors provide 2 high adhesive applied vinyl letters
for room names and room numbers. Layout to be similar to other room sign layouts. No
braille required at these doors per IBC E107.2 exception 1.

DIRECTIONAL AND INFORMATIONAL SIGNAGE (DS)


2.3.1.

Manufacturer: Advance Corporation http://www.advancecorp.com/ (specified as basis of


design) or equal.

2.3.2.

Type: Etched metal signage system, unless noted otherwise.

2.3.3.

Series: Etched Zinc Photocast.

2.3.4.

Material Characteristics: 0.153 inch thick zinc alloy.

2.3.5.

Graphic Image Process: Acid etched process providing raised and braille relief image.
Applied message not acceptable.

2.3.6.

Sign Size, Design, Style Criteria:

2.3.7.

2.3.6.1.

Character size: As required to comply with viewing distance criteria. Provide


minimum 3 inch height at signs located 80 inches or greater above finish
floor. Provide image raised 1/32 inch above surface.

2.3.6.2.

Character proportion: Provide width to height ratio between 3:5 and 1:1.

2.3.6.3.

Character stroke proportion: Provide stroke width to height ratio between 1:5
and 1:10.

2.3.6.4.

Letter Style: Upper case Helvetica Regular.

2.3.6.5.

Center all copy in field.

Sign Message:
2.3.7.1.

DS-1 - Exit Signs: Per detail.

2.3.7.2.

DS-2 - Exit Route: Per detail.

2.3.7.3.

DS-3 - Enclosed Stairway Signs: Per detail

2.3.7.4.

DS-3 - Exit Stair Down: Per detail.

2.3.7.5.

DS-4 - Delayed exit sign: Per detail.

2.3.7.6.

DS-5 - This Door to Remain Unlocked During Business Hours: Per detail.

2.3.7.7.

DS-6 - Assistive Listening Device: Per detail

2.3.7.8.

DS-7 - Maximum occupant capacity: Per detail.

Tule River Justice Center


Tule River Tribal Counsel
NTD # 2013-0023-00

SIGNAGE
10 14 00 - 4

2.3.8.

2.3.9.

2.4.

2.3.7.9.

DS-8 - Evacuation plan: Per detail.

2.3.7.10.

DS-9 - In Case of Fire Do Not Use Elevator, Use Stairwell" Per detail.

2.3.7.11.

DS-10 Stair Identification: Provide sign at each stair complying with IBC,
identifying stairway number, roof access, floor level, and upper/lower level
terminations.

Finish/Contrast/Color:
2.3.8.1.

Finish: Provide signs with matte, non-reflective finish, with a maximum 11-19
degree gloss on 60 degree dosimeter.

2.3.8.2.

Contrast: Provide signs with minimum light to dark contrast between


background and message of 70 percent.

2.3.8.3.

Color: Provide signs with two colors as selected by Architect from


manufacturers standard color line.
2.3.8.3.1.

Background: Color 1, selected from very dark color range.

2.3.8.3.2.

Message: Color 2 selected from white or very light color


range.

2.3.8.3.3.

International Symbol of Accessibility: White symbol on


Federal Blue background.

2.3.8.3.4.

Finish System: Mathews acrylic polyurethane coating


system, VOC approved, complying with glare finish criteria.

Mounting:
2.3.9.1.

Exterior: Provide stainless steel spanner head tamper resistant screw in


expansion shields suitable for substrate. Countersink screw flush with
surface.

2.3.9.2.

Interior: Unless noted otherwise, provide double stick foam tape mounting,
1/32 inch thick.

2.3.9.3.

Where signs are mounted on glass panels, install using structural silicone
sealant method specified in this Section.

2.3.9.4.

Verify surfaces with irregular or rough finish have been properly finished to
establish flush and lip free installation.

ACCESSIBLE ENTRANCE SIGN (AS)


2.4.1.

Provide Vomar http://www.vomarproducts.com/ or equal, acrylic die cut graphic decal,


complying with the following criteria:
2.4.1.1.

AS-1 - International Symbol of Accessibility.

2.4.1.2.

Mounting/Location: Self adhesive, mounted as directed by Architect at facility


entrances.

2.4.1.3.

Size: 4 inches square.

Tule River Justice Center


Tule River Tribal Counsel
NTD # 2013-0023-00

SIGNAGE
10 14 00 - 5

2.4.1.4.
2.5.

Color: White image on "Accessible" blue color.

SITE SIGNAGE
2.5.1.

Manufacturer: Vomar http://www.vomarproducts.com/ or equal.

2.5.2.

Type: Non-illuminated flat sign panel, aluminum, ground set unless noted otherwise.

2.5.3.

Size and Construction:

2.5.4.

2.5.3.1.

Sign Image Size: Per details. Adjust size as necessary to accommodate


message and character size criteria of referenced regulations.

2.5.3.2.

Mounting Height: Per details.

2.5.3.3.

Sign Panel Material: 0.080 inch Aluminum panel, background painted with
PPG Duranar, Kynar 500 fluoropolymer painted finish complying with AAMA
605.2-90.

2.5.3.4.

Post: Galvanized 2x2x1/4" steel tube.

Sign Size, Design, Style Criteria:


2.5.4.1.

Character size: As required to comply with viewing distance criteria. Provide


minimum 3 inch height at signs located 80 inches or greater above finish
grade.

2.5.4.2.

Character proportion: Provide width to height ratio between 3:5 and 1:1.

2.5.4.3.

Character stroke proportion: Provide stroke width to height ratio between 1:5
and 1:10

2.5.4.4.

Letter Style: Upper case Helvetica Regular. Center all text in field of frame

2.5.5.

Graphic Process: Silkscreen, surface printing, urethane paint system suitable for exterior
application, with clear urethane overcoat.

2.5.6.

Finish/Contrast/Color:
2.5.6.1.

Finish: Provide signs with matte, non-reflective finish, with a maximum 19


degree gloss on 60 degree dosimeter.

2.5.6.2.

Contrast: Provide signs with minimum light to dark contrast between


background and message of 70 percent.

2.5.6.3.

Color: Provide signs with two colors as selected by Architect from


manufacturers standard color line.

Tule River Justice Center


Tule River Tribal Counsel
NTD # 2013-0023-00

2.5.6.3.1.

Background: Color 1, selected from very dark color range.

2.5.6.3.2.

Message: Color 2 selected from white or very light color


range.

2.5.6.3.3.

International Symbol of Accessibility: White symbol on


Federal Blue background.

2.5.6.3.4.

Frame: Color as selected by Architect.

SIGNAGE
10 14 00 - 6

2.5.7.

2.6.

2.7.

Mounting:
2.5.7.1.

Ground Set: Concrete footing and post.

2.5.7.2.

Exterior Wall: Provide spanner head tamper resistant screw in expansion


shields suitable for substrate.

2.5.7.3.

Verify surfaces with irregular or rough finish have been properly finished to
establish flush and lip free installation.

SITE VEHICLE CONTROL SIGNAGE


2.6.1.

Manufacturer: Western Highway Products www.westernhighway.com or equal.

2.6.2.

Provide painted aluminum series, design as shown on drawings and as specified, with
H6-TP spanner head vandal resistant fasteners, H-5 spacer and all required mounting
components. All accessible signs shall be painted with white message on dark blue
background.
2.6.2.1.

Type 1 - Stop Sign: Per detail

2.6.2.2.

Type 2 - Speed Limit: Per detail

2.6.2.3.

Type 3 - Pedestrian crossing: Per detail

2.6.2.4.

Type 4 - Do not enter: Per detail

2.6.2.5.

Type 5 - Staff and services vehicle only: Per detail

2.6.2.6.

Type 6 - No Parking-Fire Lane Sign: Per detail

2.6.2.7.

Type 7 - Accessible Parking Space Sign: Per detail

2.6.2.8.

Type 8 - Van Accessible Parking Space Sign: Per detail

2.6.2.9.

Type 9 - Accessible Parking Site Entrance Sign: Per detail

2.6.3.

Concrete: 3,000 psi concrete in accordance with the provisions of Section 03 30 00.

2.6.4.

Post: Steel pipe, 3 inch diameter unless noted otherwise, galvanized per Section
05 50 00, finish painted per Section 09 91 00.

SAFETY SIGNAGE (ES)


2.7.1.

Exterior Safety Signage: Provide custom painted aluminum series matching Article 2.3
Directional Signage specified above, with spanner head vandal resistant fasteners,
spacer and all required mounting components. Provide signage as shown on drawings,
required by jurisdictional authorities, and related signage, including but not necessarily
limited to, signs with the following message:
2.7.1.1.

ES-1 - Fire Riser: Per detail

2.7.1.2.

ES-2 - GAS SHUT-OFF VALVE: Per detail

Tule River Justice Center


Tule River Tribal Counsel
NTD # 2013-0023-00

SIGNAGE
10 14 00 - 7

2.7.1.3.

2.8.

Fire Lane Signage and Delineation: Fire lanes must be identified regarding
their entrance and physical location with the placement of signs, gates,
curbs, bollards and similar devices. Specific signage wording and other
details must be coordinated with and approved by local fire authorities.

EXTERIOR ALUMINUM LETTERS


2.8.1.

Manufacturer: A.R.K. Ramos http://www.arkramos.com/ or equal.

2.8.2.

Type: Cast aluminum letters, wall mounted.

2.8.3.

Series: Standard Cast Aluminum Letters.

2.8.4.

Size and Construction:

2.8.5.
RFI#073

2.9.

2.8.4.1.

Size: As shown on Drawings, 12 inch minimum.

2.8.4.2.

Material: Aluminum.

Graphics and Message


2.8.5.1.

Letter Style: Per referenced standard, upper case Helvetica Medium No.
521.

2.8.5.2.

Message:
2.8.5.2.1.

Street Address Numerals: Provide two, 5 digit number sets,


located as directed by Architect at two separate locations.

2.8.5.2.2.

Function Identification: as shown on drawings

2.8.6.

Mounting Hardware: PM-2, tamper resistant fasteners with collars as detailed on


drawings.

2.8.7.

Color: F-4 Anodized Satin Aluminum with clear protective coating.

INTERIOR DIRECTORY

2.10.

2.9.1.

Provide Vomar http://www.vomarproducts.com/ 300 Series directory, non-illuminated,


surface mounted, with clear acrylic glazing.

2.9.2.

Size: 31-1/4 inches wide x 38 inches high.

2.9.3.

Finish: Black Duranodic finish.

2.9.4.

Interior Message Display: Interchangeable acrylic plastic strips retained within directory
frame channels and stacked one upon the other.

EXTERIOR MONUMENT SIGNAGE


2.10.1.

Provide A.R.K Ramos or equal, cast aluminum letters and logo / emblem /plaque as
indicated on drawings.

2.10.2.

All mounting to be concealed, provide manufacture approved mounting options.

Tule River Justice Center


Tule River Tribal Counsel
NTD # 2013-0023-00

SIGNAGE
10 14 00 - 8

2.11.

OTHER MATERIALS
2.11.1.

Provide all other materials, not specifically described but required for complete and
proper installation of this work, as selected by the Contractor and subject to the approval
of the Architect.

3.

PART 3 - EXECUTION

3.1.

SURFACE CONDITIONS
3.1.1.

3.2.

Inspection
3.1.1.1.

Prior to work of this Section, carefully inspect previously installed work.


Verify all such work is complete to the point where this installation may
properly commence.

3.1.1.2.

Verify that work of this Section may be installed in strict accordance with the
original design, all pertinent codes and regulations, and all pertinent portions
of the referenced standards.

3.1.1.3.

In the event of discrepancy, immediately notify the Architect.

3.1.1.4.

Do not proceed with installation in areas of discrepancy until all such


discrepancies have been fully resolved.

INSTALLATION
3.2.1.

3.2.2.

3.2.3.

General criteria:
3.2.1.1.

Install in accordance with manufacturer's instructions and approved


submittals.

3.2.1.2.

Coordinate location of all signage with Architect.

3.2.1.3.

Install on clean and properly prepared surfaces.

Permanent room, directional and informational signage:


3.2.2.1.

Install signs after substrate surfaces receive final finish.

3.2.2.2.

Center room identification signage at 60 inches above floor, located on strike


side of door or as directed by Architect.

3.2.2.3.

Where signs are installed in sealant method on glass panels, provide back
plate matching sign at opposite side of glass

3.2.2.4.

When sign is installed on window surface or other similar recessed


conditions, provide spacer as required to maintain sign face within 3 inches
of outermost wall plane.

Exterior site, directional and informational signage:


3.2.3.1. Mount at locations as shown on drawings, level and plumb.
3.2.3.2.

Coordinate location with Architect.

3.2.3.3.

Mount wall mounted signage fasteners in sealant bedding.

Tule River Justice Center


Tule River Tribal Counsel
NTD # 2013-0023-00

SIGNAGE
10 14 00 - 9

3.2.4.

3.2.5.

3.2.3.4.

Where signs are mounted on gate or fence mesh, sandwich mesh between
sign and backing panel of same material and size as sign. Install using hex
bolt, tamper resistant fasteners, mounted through aluminum sleeve/spacer.

3.2.3.5.

Mount ground set signs in concrete footing, Type II cement, per Section 03
30 00.

Exterior letters and signs:


3.2.4.1.

Mount at locations as shown on drawings, level and plumb.

3.2.4.2.

Mount wall mounted signage fasteners in sealant bedding.

3.2.4.3.

Coordinate location with Architect.

Clean and polish all signage after installation.

END OF SECTION

Tule River Justice Center


Tule River Tribal Counsel
NTD # 2013-0023-00

SIGNAGE
10 14 00 - 10

Das könnte Ihnen auch gefallen