Beruflich Dokumente
Kultur Dokumente
Process
Tools
Selection
Guide
for industrial instrumentation
and electrical technicans
Process Tools
Selection Guide
Documenting
Process
Calibrator
Model
Pressure
Calibrators
Multifunction
Process
Calibrator
Temperature
Calibrators
744
743B
741B
718/718Ex
717
725
724
714
712
Page 4-6
Page 6
Page 6
Page 10-11
Page 10-11
Page 8
Page 8
Page 13
Page 13
V dc
300 V
300 V
300 V
30 V
30 V
75 mV
V ac (true-rms)
300 V
300 V
300 V
3200
3200
24 mA
24 mA
Measure
Resistance
A dc
11 k
11 k
11 k
110 mA
110 mA
110 mA
50 kHz
50 kHz
50 kHz
24 mA
24 mA
3200
A ac
Frequency
Pressure
1
10 kHz
100G: 100 psig/ 100G: 100 psig/
7 bar 2;
7 bar 2;
30G: 30psig/
30G: 30psig/
2 bar 2
2 bar 2
Temperature: RTDs
8 types
8 types
8 types
7 types
7 types
Temperature: TCs
11 types
11 types
11 types
10 types
10 types
9 types
7 types
75 mV
Source/Simulate
V dc
15 V
15 V
15 V
10 V
10 V
Resistance
11 k
11 k
11 k
3200
3200
mA dc/% scale
22 mA
22 mA
22 mA
24 mA
50 kHz
50 kHz
50 kHz
10 kHz
Temperature: RTDs
8 types
8 types
8 types
7 types
7 types
Temperature: TCs
11 types
11 types
11 types
10 types
10 types
3200
7 types
9 types
Record
Min/Max
Hold
Log data
Upload data to PC
Remote operation
Features
24 V loop supply
Hart communication
718
718Ex
3 years
3 years
3 years
1 years
3 year
3 years
3 years
3 years
3 years
A/B
A/B
Harmonics analysis
In-Rush current
Insulation resistance measurement
Waveform analysis
Intregrated current clamp
Accessories
Pressure enabled 4
3. Accessories: A. Compatible w
ProcessMeter
Test Tools
789
787
Loop
Calibrators
Industrial
Electrical Tools
715
707/707Ex
705
189
87V
124
337
1550B
43B
Page 16-17
Page 16-17
Page 16-17
Page 18
Page 18
Page 19
Page 20
Page 21
Page 21
10 V
28 V
28 V
1000 V
1000 V
1000 V
1000 V
600 V
600 V
1000 V
1000 V
1000 V
1000 V
600 V
600 V
40 M
40 M
30 M
500 M
6000
30 mA, 1 A
30 mA, 1 A
10 A
10 A
999.9 A
10 A
10 A
999.9 A
20 kHz
20 kHz
1000 kHz
999.99 kHz
50/60 Hz
K (with 80TK)
24 mA
24 mA
24 mA
3D
3D
10 V
250-5 kV
24 mA
24 mA
24 mA
24 mA
24 mA
3 years
3 years/1 year
3 years
707Ex
3 years
3 years
3 years; 1 year
on accessories
(opt.)
100 ms
40 MHz
20 MHz
A/B
with LockPak B. Compatible with ToolPak C. Accepts hanging straps from ToolPak D. Optional accessories
Documenting
Process Calibrators
Pressure
Enabled
Measure
Sourcing
DC voltage
DC current
Resistance
0.05 % reading + 50 m
0.01 % output + 40 m
Frequency
0.05 %
0.01 %
8 thermocouples
0.3 C
0.2 C
11 RTDs
0.3 C
0.1 C
Pressure
744 only: Addresses pulsed transmitters and PLCs with pulses as short as 1 ms
Manufacturer
ABB/Kent-Taylor
ABB/Hartmann & Braun
Endress & Hauser
Foxboro Eckardt
Foxboro
Honeywell
Moore Products
Rosemount
Siemens
SMAR
Viatran
Wika
Yokogawa
1 Sensor Trim not supported
Pressure
instruments
600T
Contrans P,1 AS 800 Series
CERABAR M, CERABAR S
DELTABAR S
I/A Pressure
ST3000
1151, 2088, 3001C, 3051, 3051S
SITRANS P DS
SITRANS P ES
LD301
I/A Pressure
UNITRANS
EJA
Temperature
instruments
658T1
TMT 1221, TMT 1821,
TMT 1621
TI/RTT201
STT25T1, STT25H1
3441
3044C, 644, 3144, 3244, 3144P
TT3011
T32H1
YTA 110, 310 and 320
General specifications
for Fluke 741, 743B and
744 calibrators
Data log: Measure V, mA, ohms,
frequency, temperature, pressure. One to 60 readings per
minute, 8000 readings max
Ramp: Source V, mA,
frequency, temperature. Four
steps/second; trip detect on
continuity or voltage
Loop power: Selectable, 24 V
or 28 V; 22 mA max
Environmental: 741/743
specifications apply from
+18 C to +28 C
Operating temperature:
-10 C to 50 C (typical specs to
-20 C) Pressure modules are
totally compensated and specs
apply 0 C to 50 C
Storage temperature:
-20 C to 60 C
Safety: Complies with CAN/CSA
C22.2 No. 1010.1-92, ANSI/ISA
S82.01-1994, UL3111 and
EN610-1:1993. 300 V,
Over-voltage Category II
Size/weight: 130 x 236 x
61 mm (5.1 x 9.3 x 2.4 in),
weight 1.4 kg (3 lbs, 1 oz)
Battery: Internal battery pack
NiCd, 7.2 V, 1700 mAh; NiMH
5
(744 only) 7.2 V, 3500 mAh,
typical usage, greater than
8 hours
Warranty: Three years
Calculators: Four functions plus
square root, store and recall are
built in
Documenting
Process Calibrators
Pressure
Enabled
Source
Accuracy
Accuracy
(% of reading + % of full scale)
110.000 mV dc
0.025 % + 0.015 %
110.000 mV
0.01 % + 0.005 %
1.10000 V dc
0.025 % + 0.005 %
1.10000 V
0.01 % + 0.005 %
11.0000 V dc
0.025 % + 0.005 %
15.0000 V
0.01 % + 0.005 %
110.000 V dc
0.05 % + 0.005 %
300.00 V dc
0.05 % + 0.005 %
V ac, 20 to 40 Hz
V ac, 40 to 500 Hz
V ac, 500 to 1 kHz
V ac, 1 kHz to 5 kHz
2 % + 10 counts
0.5 % + 5
2 % + 10
10 % + 20
30.000 mA dc
0.01 % + 0.015 %
Source 22.000 mA
0.01 % + 0.015 %
110.00 mA dc
0.01 % + 0.015 %
Simulate 22.000 mA
0.02 % + 0.03 %
0.01 % + 20 m
11.000
0.05 % + 50 m
11.000
110.00
0.05 % + 50 m
110.00
0.01 % + 40 m
1.1000 k
0.05 % + 0.5
1.1000 k
0.02 % + 0.5
11.000 k
0.03 % + 5
0.1 % + 10
11.000 k
1.00 to 109.99 Hz
0.05 Hz
0.00 to 0.99 Hz
110.0 to 1099.9 Hz
0.5 Hz
11.00 to 109.99 Hz
0.1 Hz
5 Hz
110.0 to 1099.9 Hz
0.1 Hz
50 Hz
2 Hz
5 Hz
0.01 Hz
For pressure specifications, see page 7. For general specifications, see page 5.
Ordering information
Fluke-741B Documenting Process Calibrator
Fluke-743B Documenting Process Calibrator
Fluke-744 Documenting Process Calibrator
Each calibrator includes TL224 Industrial Test Leads (2 sets), AC220 Test Clips (2 sets),
TP220 Test Probes (1 set), BP7217 Battery Pack, BC7217 Battery Charger, instruction
manual, NIST traceable calibration certificate with data, three-year warranty, serial
port cable (743B and 744 only), DPC/TRACK Sample Version with free PC communication utility software (743B and 744 only). With the 744 you also get a HART communication cable, HART Users Manual and a NiMH battery (instead of NiCad).
Differential
Fluke 700P00
Fluke 700P01*
Fluke 700P02
Fluke 700P22
Fluke 700P03
Fluke 700P23
Fluke 700P04
Fluke 700P24*
Gage
Fluke 700P05*
Fluke 700P06*
Fluke 700P27*
Fluke 700P07
Fluke 700P08
Fluke 700P09*
Absolute
Fluke 700PA3
Fluke 700PA4*
Fluke 700PA5
Fluke 700PA6
Vacuum
Fluke 700PV3
Fluke 700PV4
Dual
Fluke 700PD2
Fluke 700PD3
Fluke 700PD4
Fluke 700PD5
Fluke 700PD6
Fluke 700PD7
High
Fluke 700P29*
Fluke 700P30
Fluke 700P31
Linerized output
Digital communication to calibrators,
no analog losses or errors
Broad selection of ranges
Range/
resolution
Range (approx)/
resolution
Reference
uncertainty
(23 3 C)
Highside
media
1 in. H2O/0.001
10 in. H2O/0.01
1 psi/0.0001
1 psi/0.0001
5 psi/0.0001
5 psi/0.0001
15 psi/0.001
15 psi/0.001
0.25 kPa/0.0002
2.5 kPa/0.002
6900 Pa/0.7
6900 Pa/0.7
34 kPa/0.001
34 kPa/0.001
103 kPa/0.01
103 kPa/0.01
0.300 %
0.200 %
0.150 %
0.100 %
0.050 %
0.025 %
0.025 %
0.025 %
Dry
Dry
Dry
316 SS
Dry
316 SS
Dry
316 SS
Dry
Dry
Dry
Dry
Dry
Dry
Dry
Dry
316
316
316
316
316
316
316
316
SS
SS
SS
SS
SS
SS
SS
SS
30 psi/0.001
100 psi/0.01
300 psi/0.01
500 psi/0.01
1000 psi/0.1
1500 psi/0.1
207 kPa/0.01
690 kPa/0.07
2070 kPa/0.1
3400 kPa/0.1
6900 kPa/0.7
10 M Pa/0.001
0.025
0.025
0.025
0.025
0.025
0.025
%
%
%
%
%
%
316
316
316
316
316
316
SS
SS
SS
SS
SS
SS
N/A
N/A
N/A
N/A
N/A
N/A
316
316
316
316
316
316
SS
SS
SS
SS
SS
SS
5 psi/0.0001
15 psi/0.001
30 psi/0.001
100 psi/0.01
34 kPa/
103 kPa/
207 kPa/
690 kPa/
0.050
0.050
0.050
0.050
%
%
%
%
316
316
316
316
SS
SS
SS
SS
N/A
N/A
N/A
N/A
316
316
316
316
SS
SS
SS
SS
-5 psi/0.0001
-15 psi/0.001
-34 kPa/0.001
-103 kPa/0.01
0.040 %
0.040 %
316 SS
316 SS
Dry
Dry
316 SS
316 SS
1 psi/0.0001
5 psi/0.0001
15 psi/0.001
-15/30 psi/0.001
-15/100 psi/0.01
-15/200 psi/0.01
6900 Pa/0.7
34 kPa/0.001
103 kPa/0.01
-100/207 kPa/0.01
-100/690 kPa/0.07
-100/1380 kPa/0.1
0.150 %
0.040 %
0.025 %
0.025 %
0.025 %
0.040 %
316
316
316
316
316
316
Dry
Dry
Dry
N/A
N/A
N/A
316
316
316
316
316
316
3000 psi/0.1
5000 psi/0.1
10000 psi/1
20.7 M Pa/0.001
34 M Pa/0.001
69 M Pa/0.007
0.050 %
0.050 %
0.050 %
SS
SS
SS
SS
SS
SS
C276
C276
C276
N/A
N/A
N/A
SS
SS
SS
SS
SS
SS
C276
C276
C276
Pressure
Enabled
Fluke Process
Calibrators in
this guide displaying this
symbol are Pressure Enabled
units and display readings
from these Precision 700
Series Pressure Modules.
Each pressure module
includes NIST traceable
certificate, metric adapter
and instruction sheet.
Multifunction
Calibrators
Fluke 725 Multifunction Process Calibrator
and 724 Temperature Calibrator.
Compact multifunction calibrators
The Fluke 725 Multifunction Process
Calibrator and Fluke 724 Temperature
Calibrator are versatile, easy-to-use
field calibrators. Use them to test and
calibrate almost anything. The 725
and 724 feature:
Easy-to-read measure/source back
lit screen lets you view input and
output simultaneously
Perform fast linearity tests with auto
step and auto ramp features
Power transmitters with internal
loop supply
Store frequently-used test setups for
later use
Measure Volts, mA, RTDs, thermocouples and ohms to calibrate transmitters
Source/simulate volts, thermocouples, RTDs and ohms to calibrate
transmitters
Channel A
Channel B
Fluke-725 Multifunction
Process Calibrator
Fluke-724 Temperature Calibrator
M or S(1)
30.000 V dc measure
100.00 mV dc
M or S
M
M or S
3200 Ohms
M or S
T/C: J, K, T, E, R, S, B, L, U, N, XK, BP
M or S
M or S
S = Source/Simulate
(1)
725 only
M(1)
Range
Resolution
Accuracy
Notes
Voltage
0 to 100 mV
0 to 10 V (source)
0 to 30 V (measure)
0.01 mV
0.001 V
0.001 V
Max load, 1 mA
0 to 24
0.001 mA
mV (TC terminals)
-10.00 mV to + 75.00 mV
.01 mV
Resistance
0 to 3200 (measure)
15 to 3200 (source)
0.01 to 0.1
0.10 to 1.0
Frequency source
(725 only)
0.1 CPM
1 Hz
0.1 kHz
0.05 % of setting
0.05 % of setting
0.25 % of setting
Frequency measure
(725 only)
1 CPM to 10 kHz
5 digits
1 V p-p min.
Loop Supply
24 V dc
N/A
10 %
T/C
Measure or Source
Measure or Source
-200 to 0 C
0 to 1200 C
1.0 C
0.7 C
XK
-200 to -100 C
-100 to 800 C
0.5 C
0.6 C
-200 to 0 C
0 to 1370 C
1.2 C
0.8 C
BP
0 to 800 C
800 to 2500 C
1.2 C
2.5 C
-200 to 0 C
0 to 400 C
1.0 C
0.8 C
Resolution
-200 to 0 C
0 to 950 C
0.9 C
0.7 C
B, R, S
-20 to 0 C
0 to 500 C
500 to 1750 C
2.5 C
1.8 C
1.4 C
-20 to 0 C
0 to 500 C
500 to 1750 C
2.5 C
1.8 C
1.5 C
600 to 800 C
800 to 1000 C
1000 to 1800 C
2.2 C
1.8 C
1.4 C
-200 to 0 C
0 to 900 C
0.85 C
0.7 C
-200 to 0 C
0 to 400 C
-200 to 0 C
0 to 1300 C
J, K, T, E, L, N, U, XK, BP
0.1 C, 0.1 F
1 C, 1 F
-80 C to 260 C
0.2 C
0.2 C
-200 C to 800 C
0.33 C 0.33 C
Pt 100 - 3926
-200 C to 630 C
0.3 C
0.3 C
Pt 100 - 3916
-200 C to 630 C
0.3 C
0.3 C
1.1 C
0.75 C
Pt 200 - 385
-200 C to 250 C
250 C to 630 C
0.2 C
0.8 C
0.2 C
0.8 C
1.5 C
0.9 C
Pt 500 - 385
-200 C to 500 C
500 C to 630 C
0.3 C
0.4 C
0.3 C
0.4 C
Pt 1000 - 385
-200 C to 100 C
100 C to 630 C
0.2 C
0.2 C
0.2 C
0.2 C
Resolution
RTD
0.1 C, 0.1 F
General specifications
for Fluke 724 and 725
calibrators
Maximum voltage: 30 V
Storage temperature:
-20 C to 71 C
Operating temperature:
-10 C to 55 C
Relative humidity:
90 % (10 C to 30 C);
75 % (30 C to 40 C);
45 % (40 C to 50 C);
35 % (50 C to 55 C)
Shock:
9
30 g, 11ms, half-sine shock
Vibration:
Random, 2 g, 5-500 Hz
Safety: CSA C22.2 No.1010.1:1992
EMC: EN50082-1:1992 and
EN55022:1994 Class B
Size/weight: 96 x 200 x 47 mm
(3.8 x 7.9 x 1.9 in)
650 g (23 oz)
Battery: Four AA alkaline
batteries.
Battery life: 25 hours typical
Warranty: Three years
Pressure
Calibrators
Pressure
Enabled
718Ex Intrinsically
Safe Pressure Calibrator
model available.
The Fluke 718Ex Intrinsically
Safe Pressure Calibrator offers high
performance in an ATEX-rated pressure
calibrator. A complete, self-contained
calibration and switch test solution,
the 718EX offers:
II 1G EEx ia IIC T4
ATEX
compliance.
I.S. Class I, Division 1 Groups A-D,
T-4 compliance.
Compatibility with eight intrinsically
safe pressure modules (see page 7).
0344
10
Ordering information
Pressure Calibrators
Fluke-718 30US
Fluke-718 100US
Fluke-718Ex 30G
Fluke-718Ex 100G
Fluke-717 30G
Fluke-717 100G
Each calibrator includes protective holster, test
leads and alligator clips, 9 V alkaline battery
(two on the 718), product overview in 14 languages, users manual on CD-ROM (718 only),
NIST-traceable certificate of calibration; CE and
CSA markings. Fluke-718 includes protective
in-line filter.
718Ex/718 30G
Range
Accuracy
Notes
Measure pressure1
(internal sensor)
Over pressure 3xFS
-12 to 30 psi
0.001 psi
(-83 to 207 kPa) scale (0.01 kPa)
0.05 % full
Gases/liquids 717
only (non-corrosive)
Use the 718 with
non-corrosive
gases only
Zero, Min, Max, Hold,
Damp
Measure Pressure1
(internal sensor)
Over pressure 2xFS
0.05 %
full scale
Gases/liquids 717
only (non-corrosive)
Use the 718
with non-corrosive
gases only
Zero, Min, Max, Hold,
Damp
Measure pressure1
(with pressure
modules, modules)
Over pressure per
pressure
module specs2
29 Pressure
1.0 in. H20/
0.25 kPa to
10,000 psi/
69 MPa
To 0.0001 psi,
per pressure
module specs2
To 0.05 %
of full
span, per
pressure
Media compatibility
per Pressure Module
Specs2 Zero,
Min, Max,
Hold, Damp
Source pressure,
built-in pump
-11 psig to
full scale
N/A
N/A
Measure mA
0 to 24 mA
0.001 mA
0.025 %
+ 1 count
(718 only)
Resolution
(718 only)
Pressure
General specifications
for all Fluke 717 and 718
and 718Ex calibrators
Function
718Ex/718 100G
717 30G
717 100G
Loop supply
24 V dc
N/A
10 %
Drive; 20 mA into
1000 for battery
> 6.8 V; 700
for battery
5.8 to 6.8 V
1 Supported pressure units; psi, in. H20 (4 C), in. H20 (20 C), cm H20 (4 C), cm H20 (20 C),
bar, mbar, kPa, inHg, mmHg, kg/cm2
2 Pressure module specifications, see page 7
Maximum voltage: 30 V
Non-operating temperature:
-40 C to 60 C
Operating temperature:
-10 C to 55 C
Relative humidity:
95 % (10 C to 30 C); 75 %
(30 C to 40 C); 45 % (40 C to
50 C); 35 % (50 C to 55 C)
Operating altitude:
3,000 m max
Shock: 1 m drop test
Vibration: Random, 2 g,
5-500 Hz
Safety: CSA C22.2 No.
1010.1:1992 (Call Fluke for
718Ex safety ratings)
EMC: EN50082-1:1992 and
EN55022:1994 Class B
Size/weight, (717 with holster
and Flex-Stand):
201mm L x 98 mm W x 52 mm D
(7.93 in L x 3.86 in W x 2.06 in
D) 600 g (21 oz)
Size/weight, (718 with holster):
216 mm L x 94 mm W x 66 mm
D (8.50 in L x 3.72 in W x
2.60 in D) 992 g (35 oz)
Power: 9 V battery ANSI/NEDA
1604 A or IEC 6LR61 9V
11
alkaline; two batteries in 718
Battery Life: 4 to 20 hours, typical, depending on functions used
Warranty: Three years (one year
on pressure pump in Fluke 718);
one year for 718Ex.
700SW DPC/TRACK
Software
Ordering information
Fluke-700SW DPC/
TRACK Software
12
Include comments as to
Reasons for Work, Problems
Found, and Actions taken
(743 and 744 only).
Unload your results to a PC.
Print a selection of preformatted reports.
Examine the calibration
histories of your tags and
instruments.
Import instrument data and
procedures as ASCII text.
Export instrument data,
procedures, and results as
ASCII text.
DPC/TRACK operates in the
same languages as the DPCs:
English, French, German,
Italian, and Spanish. A
Pentium-based machine is
recommended.
DocuMint
On Time
Support
Temperature
Calibrators
712 RTD Calibrator
Complete RTD calibration tool
Measure temperature
from TC output
Simulate TC output
Nine types of thermocouples
Calibrate linear TC transmitter
with mV source function
Thermocouple mini-jack
termination
TC (174)
RTD (712)
Range
Resolution
Accuracy
Notes
Measure/simulate
RTD(712)
-200 to 800 C
(Pt 100)
0.1 C, 0.1 F
0.33 C, 0.6 F
(Pt 100)
Measure/simulate
Resistance
15 to 3200
0.1
0.1 to 1
Measure/simulate
Thermocouple
-200 to 1800 C,
depending on type
(K,-200 to 1370 C)
0.1 C or F
(1 C or F; BRS)
Measure/simulate mV
-10 to 75 mV
0.01 mV
0.025 % + 1 count
9 TC types;
J K T E R S B per NIST
175 and ITS-90
L U per DIN 43710 and IPTS-68
13
ProcessMeter
Test Tools
Multimeter and Loop Calibrator all in one
Fluke 789 ProcessMeter
Ordering information
Fluke-789 ProcessMeter
14
Fluke-787 ProcessMeter
Includes C81Y Protective Yellow Holster with
Flex-Stand, TL75 Safety-Designed Test Lead
Set plus AC70A Alligator Clips, one 9 V alkaline
battery (installed), product overview and users
manual (CD-ROM) in 14 languages.
Simultaneous mA and % of
scale readout on mA output
25 % Manual Step plus auto
step and auto ramp on mA
output
Clear LCD with backlight;
4,000 counts (30,000 counts
for dc current)
Min, Max, Average, Hold,
Relative modes
Externally accessible battery
for easy battery changes
CAT III 1000 V safety-rated
multimeter
DC current simulate
(ext. 24 Volt loop supply)
24 V loop supply
Current adjustment modes
Best accuracy
range and resolution
400.0 mV, 4.000 V, 40.00 V,
400.0 V, 1000 V
400.0 mV, 4.000 V, 40.00 V,
400.0 V, 1000 V
30.000 mA
1.000 A (0.440 A continuous)
1.000 A (0.440 A continuous)
400.0 Ohms, 4.000 k, 40.00 k,
400.0 k, 4.0 M, 40 M
199.99 Hz, 1999.9 Hz, 19.999 kHz
789: 2.000 V (shows diode voltage drop)
787: 2.400 V (shows diode voltage drop)
Beeps for resistance < approx. 100 ohms
Range and resolution
0.000 to 20.000 mA or
4.000 to 20.000 mA
(selectable at power-up)
Over-range to 24.000 mA
0.000 to 20.000 mA or 4.000 to 20.000 mA,
(selectable at power-up)
Over-range to 24.000 mA
789: Minimum 24 V
787: not available
Manual: Coarse, Fine, 25 % step
Automatic: Slow Ramp, Fast Ramp, 25 % step
(% of reading + LSD)
0.1 % + 1
0.7 % + 2
.05 % + 2
0.2 % + 2
1%+2
0.2 % + 1
.005 % +1
2%+1
Drive
capability
789: 24 V compliance
or, 1200 @ 20 mA
787: 12 V compliance
or, 500 @ 24 mA
789: 15 V to 48 V
787: 15 V to 30 V
Accuracy
(% of span)
.05 %
.05 %
24 V @ 24 mA,
1200 (789 only)
15
Battery (787): Single 9 V alkaline
battery
Battery life (787): 12 to 50 hours
typical
Battery (789): Four AA alkaline
batteries
Battery life (789): 14 to 140 hours
typical
Warranty: Three years
Loop
Calibrators
Fluke 707 Loop
Calibrator
Fluke 707
Ordering information
Fluke-707 Loop
Calibrator
16 Fluke-707Ex Loop
Calibrator
Fluke-705 Loop
Calibrator
Fluke-715 Volt/mA
Calibrator
Each calibrator includes test
leads, test clips, holster,
instruction sheets, NISTtraceable certificate of
calibration; CE and CSA
markings and 9 V alkaline
battery.
Fluke 707Ex
Intrinsically Safe
Loop Calibrator
The 707Ex includes the
great features of the standard
707. It also is certified in
accordance with the ATEX
directive (
II 2 G
EEx ia IIC T4) and Factory
Mutual N.I. Class 1,
Division 2, Group A-D.
Fluke 707Ex
Intrinsically Safe
Loop Calibrator
Fluke 705
Fluke 715
Range
Voltage measure
0 to 28 V
.001 V
0 to 10 V
.001 V (715)
N/A
mA measure
0 to 24 mA
.001 mA
mA source1
0 to 24 mA
.001 mA
mA simulate2
0 to 24 mA
.001 mA
Loop supply
24 V dc
n/a
24 V, no load
24 V, no load
Maximum voltage: 30 V
Non-operating temperature: -40 C to 60 C
Operating temperature: -10 C to 55 C
Relative humidity: 95 % (10 C to 30 C); 75 %
(30 C to 40 C); 45 % (40 C to 50 C); 35 %
(50 C to 55 C)
Operating altitude: 3,000 meters maximum
Shock: 1 meter drop test
Vibration: Random, 2 g, 5-500 Hz
Safety: CSA C22.2 No. 1010.1:1992
EMC: EN50082-1:1992 and EN55022:1994 Class B
Size/weight: 187 mm L x 87 mm W x 32 mm D
(7.35 in L x 3.41 in W x 1.25 in D) 330 g (12 oz)
Size/weight (with holster and Flex-Stand):
201 mm L x 98 mm W x 52 mm D (7.93 in L x
3.86 in W x 2.06 in D) 600 g (21 oz)
Battery life: 4 to 20 hours
Warranty: Three years
17
Industrial
Electrical Tools
Fluke 87V Industrial
Multimeter
Accuracy and diagnostics
for maximum industrial
productivity
The new Fluke 87V has improved
measurement functions, troubleshooting features, resolution and accuracy to
solve more problems on motor drives,
plant automation, power distribution,
and electro-mechanical equipment.
Unique function for accurate voltage
and frequency measurements on
adjustable speed motor drives and
other electrically noisy equipment.
Built-in thermometer conveniently
allows you to take temperature readings without separate instrument.
Ordering information
Fluke 87-5
Industrial Multimeter
Fluke 189
18 Logging Multimeter
Meters include test leads, alligator clips, batteries (installed),
Getting Started manual,
operators manual and application notes on CD. Model 87V
includes a temperature probe.
87V
0.05 %,
Relative mode to remove test lead resistance from low ohms measurements
Cat IV 600 V and Cat III 1000 V electrical safety ratings
0.025 %
10 V,
1 V
20 KHz,
100 KHz
200 KHz,
1 MHz
189
Industrial
Electrical Tools
ScopeMeter 120 Series Handheld Oscilloscope
For industrial electrical, electronic and
process troubleshooting applications
Summary specifications
Bandwidth
25 MS/s
up to 2.5GS/s
Number of inputs/digitizers
Glitch capture
40 ns
Trigger types
Scope measurements
26 automatic measurements
Cursors
Yes
Yes
20
True-rms multimeter
Battery (installed)
Line power
Size
Weight
1.2 kg
Warranty
Ordering information
Fluke 124/S
Industrial ScopeMeter, 40 MHz,
with SCC120
Fluke 124
Industrial ScopeMeter, 20 MHz
Fluke 124S includes
Hard-shell carrying case,
optically isolated RS-232
adapter/cable and FlukeView
for ScopeMeter Windows
software
19
Industrial
Electrical Tools
Fluke 337 Clamp Meter
The Fluke 337 Clamp Meter is the ultimate handheld tool
for troubleshooting variable speed drives and motors
Features
337
Backlight
Amps ac
999.9
Amps dc
999.9
True-rms
Volts ac/dc
Ordering information
Fluke 337
Meter includes soft carrying
20 case, test leads, two batteries,
instruction card and safety
information.
Basic current
accuracy
600.0
2%
Resistance (Ohms)
600.0/6 K
Continuity beeper
Frequency (Hz)
Min/Max capture
Inrush current
DC zero button
Jaw size
Maximum wire size
400.0
1.7 in/43mm
750 MCM
Optional accessories
C33 Soft Carrying Case
H3 holster with test lead storage
TL220 Industrial Test Lead Set,
includes one pair (red and black):
AC220, TP220, TL222. 1000 V CAT III,
600 V CAT IV, 10A.
TL223 Electrical Test Lead Set,
includes one pair (red and black):
AC220, TP1 and TL224. 1000 V CAT III,
600 V CAT IV, 10A.
TL71 Precision Probe Assembly,
safety-shrouded, right-angle inputs.
1.2 m (48 in). 1000 V, 10 A. UL 3111-1
Listed.
TL76 4 mm Diameter Test Leads, consists of one red and one black test lead
1.5 m (59 in) long.
Industrial
Electrical Tools
Fluke 1550B MegOhmMeter
Digital insulation testing from 250 to
5000 volts for preventive maintenance
The Fluke 1550B is a versatile, rugged
digital MegOhmMeter capable of testing switchgear, motors, generators, and
cables at up to 5000 V dc, making it a
powerful preventive and predictive
maintenance tool.
Standard test voltages of 250 V,
500 V, 1000 V, 2500 V and 5000 V
Programmable test voltages available
in 50 volt steps from 250 to 1000
volts and 100 volt steps from 1000 to
5000 volts
Ordering information
Fluke 1550B
MegOhmMeter
Included accessories
Test leads, 5000 V-rated probes,
alligator clips, interface adapter
and cable, Quicklink 1550 PC
software, line cord, soft carrying
case and users manual.
Thermometers
Fluke 51
Digital Thermometer,
single input
Fluke 52
Digital Thermometer,
dual input
22
Ordering information
Fluke 53
Datalogging Thermometer,
single input,
Fluke 54
Datalogging Thermometer,
dual input
Fluke-51-2
Fluke-52-2
Fluke-53-2
Fluke-54-2
Fluke-61
Fluke-65
61 Infrared Thermometer
65 Infrared Thermometer
Fluke 61 Infrared
Thermometer
Fluke 65 Infrared
Thermometer
54-II
53-II
52-II
51-II
K, J, T, E, N, R, S
K, J, T, E, N, R, S
J, K, T, E,
J, K, T, E,
Time of day
Relative time
65
61
23
Calibrators
Selection Guide
Field
Dry-Well
Dry-Well Calibrators
Model
Thermocouple
Furnace
9100S
9102S
9009
9141
9103
9140
9150
Page 27
Page 27
Page 26
Page 28
Page 28
Page 28
Page 31
35 C to 375 C
-10 C to 122 C
50 C to
350 C: Hot
-15 C to
110 C: Cold
50 C to 650 C
-25 C to 140 C
35 C to 350 C
150 C to 1200 C
610
Page
Measure
Temperature RTD
Temperature, thermometer
Accuracy
Resolution
Source/Simulate
Temperature, dry-well
Temperature bath
35 C to
Temperature infrared
Stability
.07 C
0.05 C
.05 C
.05 C
0.02 C
0.03 C
0.5 C
0.02
Accuracy
0.25 C
0.25 C
0.6 C: Hot
0.2 C: Cold
0.5 C
0.25 C
0.5 C
5.0 C
0.25
Remote operation*
Serial interface
2 years
2 years
1 year
1 year
1 year
1 year
1 year
Record
Min Max
Upload data to PC
Logging to PC
Logging, internal memory
Features
24
Warranty
NIST-Traceable certification
Power
1 ye
Line
Line/Battery
Line
Line
Line
Line
Line
Lin
* Interface-it software, model 9930, is included with all dry-wells and baths in this selection guide. See page 37.
Micro-Baths
02
e 35
200 C
Infrared
Calibrators
Thermometer
Readouts
7102
7103
9132
9133
1521
1522
1502
1529
1620-S
Page 35
Page 35
Page 30
Page 30
Page 33
Page 33
Page 34
Page 32
Page 36
-5 C to 125 C
-30 C to 125 C
2 C
.015 C
.0.03 C
0.1 C
0.1 C
5 C
0.25 C
0.25 C
0.5 C
0.4 C
ear
ne
ThermoHygrometer
50 C to 500 C
-200 C
to 962 C
-200 C
to 962 C
-200 C
to 962 C
-189 C
to 962 C
0 C to 50 C
0.025 C
to 0.15 C
0.025 C
to 0.15 C
0.004 C
to 0.024 C
0.004 C
to 0.024 C
0.25 C
2.0 % RH
0.001 C
0.001 C
0.001 C
0.001 C
0.001 C
0.01 % RH
8,000 points
400,000 points
-30 C to 150 C
10,000 points
1 year
1 year
1 year
1 year
1 year
1 year
3 years
2 years
1 year
Line
Line
Line
Line
Battery
Battery
Line
Battery
Line
25
Dual-Block
Calibrators
Hart Scientific 9009 Industrial Dual-Block Calibrator
Double your productivity or cut your calibration time in half
Harts new 9009 Industrial
Dual-Block Calibrator lets you calibrate
temperature probes from -15 C to
350 C. Each temperature well is independently controlled, so while youre
checking your transmitter sensor at
one temperature, the other well
can be heating or cooling to your next
set-point.
Ordering information
Summary specifications
9009-B-156
Range
Hot block
Cold block
9009-B-256
26
Accuracy
Hot block
0.6 C
3102-1
Cold block
0.2 C
Stability
3102-2
Hot block
0.05 C
Cold block
0.05 C
3102-3
Well-to-well uniformity
0.1 C
Stabilization time
8 minutes
3102-4
Insert, AL 1/4 in (6.4 mm)
3102-6
Insert, AL 3/8 in (9.5 mm)
3102-7
Well depth
Removable inserts
Two 1.4 in (6.4 mm) and two 3/16 in (4.8 mm) inserts included;
see ordering information for other available inserts
Power
Size
3102-8
Weight
Cold block
Handheld
Dry-Wells
Hart Scientific 9100S and 9102S Handheld Dry-Well
Temperature Calibrators
The smallest, lightest and most portable
dry-wells in the world
Hart dry-wells are the smallest, lightest Fast and easy calibrations of RTDs
and most portable dry-wells in the
world. The model 9100 weighs only
2 pounds, 3 ounces (1 kilogram).
Temperature ranges from
-10 C to 375 C
Stability during calibrations
to 0.05 C
and thermocouples
Includes RS-232 interface,
instrument control software
Direct interface to the Fluke 744
Summary specifications
9100
9102
Range
Accuracy
0.5 C
0.25 C
Stability
0.1 C at 100 C
0.3 C at 375 C
0.05 C at 0 C
Well-to-well
Uniformity
Stabilization
5 minutes
7 minutes
Well depth
102 mm (4 in);
1.6 mm (1/16 in) hole
is 89 mm (3.5 in) deep
102 mm (4 in)
Removable inserts
N/A
Power
94-234 V AC ( 10 %),
50/60 Hz, 60 W; or 12 V DC
Size
57 x 125 x 150 mm
(2.25 H x 4.9 W x 5.9 in D)
99 x 140 x 175 mm
(3.9 H x 5.5 W x 6.9 in D)
Weight
1 kg (2 lb. 3 oz.)
1.8 kg (4 lb.)
NISTtraceable
calibration
Data at 50 C, 150 C,
200 C, 250 C,
300 C and 350 C
Data at -10 C, 24 C,
50 C, 55 C, 100 C
and 122 C
Ordering information
9100S-A-156 Dry-Well, Block A (1)
9100S-A-256 Dry-Well, Block A (2)
9100S-B-156 Dry-Well, Block B (1)
9100S-B-256 Dry-Well, Block B (2)
9100S-D-156 Dry-Well, Block D (1)
9100S-D-256 Dry-Well, Block D (2)
9300 Rugged Carrying Case, 9100
9102S-156 Dry-Well, -10 to 122 (2 Wells) (1) (3)
9102S-256 Dry-Well, -10 to 122 (2 Wells) (2) (3)
9320-156 Battery Pack, 9102 (1)
9320-256 Battery Pack, 9102 (2)
3102-1 Insert, AL 1/16 in (1.6 mm)
3102-2 Insert, AL 1/8 in (3.2 mm)
3102-3 Insert, AL 3/16 in (4.8 mm)
3102-4 Insert, AL 1/4 in (6.4 mm) (Standard)
3102-6 Insert, AL 3/8 in (9.5 mm) (Standard)
3102-7 Insert, AL 7/16 in (11.1 mm) (Standard)
3102-8 Insert, AL 5/32 in (4 mm) (Standard)
9308 Hard Carrying Case, 9102/9132
156 Blocks are 115 V 50/60 Hz
256 Blocks are 220 V 50/60 Hz
(3)
Specify two 3102 inserts
(1)
(2)
27
Field Dry-Wells
Ordering information
28
Summary specifications
9103
25 C to 140 C
(13 F to 284 F)
at 23 C ambient
0.25 C
Range
Accuracy
9140
35 C to 350 C
(95 F to 662 F)
9141
50 C to 650 C
(122 F to 1202 F)
0.5 C to 400 C;
1.0 C to 650 C
(holes greater than 1/4 in: 2 C)
0.05 C at 100 C
0.12 C at 500 C
0.12 C at 650 C
0.1 C below 400 C,
0.5 C above 400 C
with similarly sized wells
12 minutes from ambient
to 650 C
25 minutes from
650 C to 100 C
Stability
0.02 C at 25 C
0.04 C at 140 C
0.03 C at 50 C
0.05 C at 350 C
Well-to-well
Uniformity
Heating times
Cooling times
Stabilization time
Immersion depth
Power
Size
Weight
Computer interface
NIST-traceable
certificate
29
1/8 in
(3.2 mm)
Insert B
1/4 in
(6.35 mm)
3/16 in
(4.8 mm)
3/8 in
(9.5 mm)
3/8 in
(9.5 mm)
3/16 in
1/4 in
(4.8 mm)
(6.35 mm)
Insert C
1/4 in
(6.35 mm)
3/8 in
(9.5 mm)
Insert D
3 mm
4 mm
6 mm
6 mm
3/16 in
1/4 in
(4.8 mm) (6.35 mm)
4 mm
3 mm
Infrared
Calibrators
Hart Scientific 9132 and 9133
Infrared Calibrators
Precision when you need it for infrared
temperature calibration
Whether youre using in-line
or handheld pyrometers, the
9132 Portable IR Calibrator
can handle your workload to
500 C (932 F). For calibrating IR guns at cold temperatures, the 9133 Portable IR
Calibrator reaches 30 C
(22 F) in normal ambient
conditions.
Simply point and shoot to
check your IR guns. For higher
precision, a well is located
directly behind the blackbody
Summary specifications
Temperature range
Ordering information
Accuracy
Stability
30
Target size
Target emissivity
Resolution
Heating time
Cooling time
Power
Size
Weight
Computer interface
NIST-traceable
contact calibration
9132
9133
50 C to 500 C
30 C to 150 C at 23 C ambient
(122 F to 932 F)
(22 F to 302 F at 73 F ambient)
0.5 C at 100 C
0.4 C
0.8 C at 500 C
0.1 C at 100 C
0.1 C
0.3 C at 500 C
2.25 in (57 mm)
0.95 ( 0.02 from 8 to 14 mm)
0.1
30 minutes (50 C to 500 C)
15 minutes (25 C to 150 C)
30 minutes (500 C to 100 C)
15 minutes (25 C to 20 C)
115 VAC ( 10 %), 3 A or
115 VAC ( 10 %), 1.5 A, or
230 VAC ( 10 %), 1.5 A,
230 VAC ( 10 %), 1.0 A,
switchable, 50/60 Hz, 340 W
switchable, 50/60 Hz, 200 W
4 H x 6 W x 7 D in
6 H x 11.25 W x 10.5 D in
(102 x 152 x 178 mm)
(152 x 286 x 267 mm)
4 lb. (1.8 kg)
10 lb. (4.6 kg)
RS-232 included with free Interface-it software
Data at 50 C, 100 C, 200 C,
Data at 30 C, 0 C, 25 C, 75 C,
250 C, 300 C, 400 C
100 C, 125 C and 150 C
and 500 C
Thermocouple
Furnace
Hart Scientific 9150 Thermocouple Furnace
Low-cost thermocouple furnace
Stability of 0.5 C
Temperature range to 1200 C
Display accuracy of 5 C across
entire range
NIST-traceable calibration included
RS-232 port standard
Insert B
1/4 in
1/2 in
3/16 in
3/8 in
3/8 in
Insert C
1/4 in
Insert D
3 mm
3/8 in
4 mm
6 mm
6 mm
1/4 in
3/16 in
1/8 in
1/4 in
3/16 in
4 mm
3 mm
Summary specifications
Temperature range
Display
resolution
Stability
Display accuracy
Well diameter
Well depth
Heating time
Cooling time
Well-to-well
uniformity
Stabilization
Power
Size
Weight
NIST-traceable
calibration
*for metric equivalents see page 29
Range
150 C to 1200 C (302 F to 2192 F)
0.1 to 999.9
1 above 1000
0.5 C
5 C
1.25 in (32 mm)
5.5 in (140 mm); (4 in [101 mm] in removable insert plus 1.5 in
[38 mm] in insulator)
35 minutes to 1200 C
140 minutes with block
0.5 C to 1.0 C
(Insert C at 1200 C)
20 minutes
115 VAC ( 10 %), 10.5 A or 230 VAC ( 10 %), 5.2 A,
switchable, 50/60 Hz, 1200 W
12.4 H x 8.2 W x 12.4 D in (315 x 208 x 315 mm)
28 lb. (13 kg)
Data at 150 C, 300 C, 450 C, 600 C, 800 C,
1000 C, and 1200 C
Ordering information
9150-X-156 Thermocouple
Furnace (specify X, X = A, B, C,
or D included insert), (110 V)
9150-X-256 Thermocouple
Furnace (specify X, X = A, B, C,
or D included insert), (220 V)
3150-1 Custom Insert
3150-2 Insert A
3150-3 Insert B
3150-4 Insert C
3150-6 Insert D
9315 Rugged Carrying Case
31
Thermometer
Readout
Ordering information
1529 Chub-E4 Thermometer, 2 TC and 2 PRT/
Thermistor Inputs
1529-R Chub-E4 Thermometer, 4 PRT/
Thermistor Inputs
1529-T Chub-E4 Thermometer, 4 TC Inputs
(Specify 110V or 220V power)
2506-1529 IEEE Option
9322 Rugged Carrying Case
See page 37 for software information.
See page 38 for optional probes.
Summary specifications
Inputs
Temperature range
Measurement range
Characterizations
32
Temperature accuracy
(meter only)
Temperature resolution
Operating range
Logging intervals
Communications
Size
Weight
Calibration
PRT / RTD
2 channels PRT/thermistor and
when ordering; PRT/thermistor
and Au-Pt TC types
189 C to 960 C
(-308 F to 1760 F)
0 to 400
ITS-90, IEC-751 (DIN 385),
Callendar-Van Dusen
Thermistor
Thermocouple
2 channels TC, or 4 channels PRT/thermistor, or 4 channels TC, specify
channels accept 2, 3, or 4 wires; TC inputs accept B, E, J, K, N, R, S, T,
50 C to 150 C
(-58 F to 302 F)
0 to 500 K
Steinhart-Hart, YSI-400
270 C to 1800 C
(-454 F to 3272 F)
10 to 100 mV
NIST Monograph 175, 3-point
deviation function applied to NIST
175, 6th-order polynomial
Ext. RJC:
Int. RJC
J at 600 C
0.1 C:
0.35 C
K at 600 C
0.15 C: 0.4 C
S at 1000 C 0.5 C:
0.6 C
T at 200 C
0.1 C:
0.3 C
0.01 to 0.001
0.004 C at 100 C
0.0025 C at 0 C
0.006 C at 0 C
0.0025 C at 25 C
0.009 C at 100 C
0.004 C at 50 C
0.018 C at 400 C
0.010 C at 75 C
0.024 C at 600 C
0.025 C at 100 C
0.001
0.0001
16 C to 30 C
0.1, 0.2, 0.5, 1, 2, 5, 10, 30, or 60 seconds; 2, 5, 10, 30, or 60 minutes
RS-232 and IR ports included, IEEE-488 (GPIB) optional
4.0 in H x 7.5 in W x 8.2 in D (102 x 191 x 208 mm)
4.5 lbs. (2 kg)
Accredited NIST-traceable resistance calibration and NIST-traceable voltage calibration provided
Handheld
Thermometer Readouts
Hart Scientific 1521 and 1522 Handheld Thermometers
Highest precision available in a battery-powered,
handheld thermometer
These handheld thermometers feature
measurement accuracy to 0.005 C
and .001 resolution. Accept inputs
from RTDs or thermistors and with
Harts INFO-CON connector theres no
need to program probe coefficients into
the meter. All data is stored in the
Summary Specifications
Pt 25 to Pt 100
Thermistor
Temperature range
Resistance range
0 to 400
0 to 500 K
Temperature accuracy
(meter only)
0 C to 50 C: 0.005 C
50 C to 75 C: 0.01 C
75 C to 100 C: 0.02 C
Excitation current
0.5 mA
5 A
Operating range
0 C to 40 C
Memory
Power
Size
Weight
Calibration
33
Ordering information
1522-156
9934-M
1521-156
Thermometer, handheld,
1 channel data logger, 110 V
Software, LogWare
1-channel, multi user
1522-256
9318
Thermometer, handheld,
1 channel data logger, 220 V
Case, 1521/1522,
probe carrying
Included: Adapter/charger
Thermometer, handheld,
1 channel, 110 V
1521-256
Thermometer, handheld,
1 channel, 220 V
9934-S
Software, LogWare
1-channel, single user
Thermometer
Readout
Hart Scientific 1502A Tweener Thermometer
Best performance thermometer in its price range
Ordering information
34
1502A-156 Tweener
PRT Thermometer (110 V)
1502A-256 Tweener
PRT Thermometer (220 V)
2502 DC Power Option
2505 Spare Connector
2506 IEEE Option
2507 Mini-Printer
2508 Serial Cable Kit
9313 Battery Pack
9301 Carrying Case, fits
Tweener and 12 in. probe
9308 Carrying Case, fits
Tweener and 6 in. probe
1930-2 System Cal Report,
RTDs
9934-S LogWare, single
channel, single user
9934-M LogWare, single
channel, multi-user
9938-16 MET/TEMP II
Software, (110 V)
9938-25 MET/TEMP II
Software, (220 V)
See page 38 for optional
probes.
Summary specifications
Temperature range
Resistance range
Probe
Characterizations
Resistance accuracy
(ppm of reading)
Temperature accuracy,
typical (meter only)
Range
200 C to 962 C (328 F to 1764 F)
0 to 400 , auto-ranging
Nominal RTPW: 25 to 100 RTD, PRT, or SPRT
ITS-90 subranges 4, 6, 7, 8, 9, 10, and 11
IPTS-68: R0, , , a4, and c4
Callendar-Van Dusen: R0, , , and
0 to 20 : 0.0005
20 to 400 : 25 ppm
0.004 C at 100 C
0.006 C at 0 C
0.009 C at 100 C
0.012 C at 200 C
0.018 C at 400 C
0.024 C at 600 C
16 C to 30 C
0 to 20 : 0.0001 20 to 400 : 0.001
0.001 C
0.5 and 1 mA, user selectable, 2 Hz
1 second
Exponential, 0 to 60 seconds time constant
(user selectable)
4-wire with shield, 5-pin DIN connector
RS-232 serial standard
IEEE-488 (GPIB) optional
8-digit, 7-segment, yellow-green LED;
0.5-inch-high characters
115 VAC ( 10 %), 50/60 Hz, 1 A, nominal
230 VAC ( 10 %), 50/60 Hz, 1 A, nominal, specify
5.6 W x 7.1 D x 2.4 in H (143 x 181 x 61 mm)
2.2 lb. (1.0 kg)
Accredited NIST-traceable calibration provided
See page 38
Temperature ranges and accuracy may be limited by the sensor you use.
Micro-Baths
Ordering information
Stability to 0.015 C
Ranges from -30 C to 200 C
Accepts oddly shaped sensors
Summary specifications
6102
7102
35 C to 200 C
5 C to 125 C
(95 F to 392 F)
(23 F to 257 F)
Accuracy
0.25 C
Stability
0.02 C at 100 C (oil 5013)
0.015 C at 5 C (oil 5010)
0.03 C at 200 C (oil 5013)
0.03 C at 121 C (oil 5010)
Operating temperature 5 C to 45 C
Heating time
25 C to 200 C: 40 minutes
25 C to 100 C: 30 minutes
Cooling time
200 C to 100 C: 35 minutes
25 C to 0 C: 30 minutes
Well size
2.5 in dia. x 5.5 in deep (64 x 139 mm)
(access opening is 1.9 in [48 mm] in diameter)
Size
5.5 W x 10.38 H x 8 D in
7.2 W x 12 H x 9.5 D in
(14 x 26 x 20 cm)
(18 x 31 x 24 cm)
Weight
10 lb. (4.5 kg) with fluid
15 lb. (6.8 kg) with fluid
Power
115 VAC, 230 VAC ( 10 %)
115 VAC, 230 VAC ( 10 %)
Computer interface
RS-232 included with free Interface-it software
NIST-traceable
Data at 50 C, 100 C,
Data at 5 C, 25 C, 55 C,
calibration
150 C, and 200 C
90 C, and 121 C
Range
7103
30 C to 125 C
(22 F to 257 F)
0.03 C at 25 C (oil 5010)
0.05 C at 125 C (oil 5010)
25 C to 100 C: 35 minutes
25 C to 20 C: 45 minutes
9 W x 13.2 H x 10.5 D in
(23 x 34 x 26 cm)
22 lb. (9.8 kg) with fluid
94234 VAC ( 10 %)
Data at 25 C, 0 C, 25 C, 50 C,
75 C, 100 C, and 125 C
35
Thermo-Hygrometer
Ordering information
36
Summary specifications
Temperature range
Temperature accuracy
Delta temperature accuracy
Temperature resolution
RH range
RH accuracy
Delta humidity accuracy
RH resolution
Inputs
Display
Memory (internal)
Alarms
Communications
PC card interface
Power
Operating range
Size (DewK)
Weight
Calibration
Description
0 C to 50 C (32 F to 122 F)
15 C to 35 C: 0.25 C (calibrated)
0 C to 15 C, 35 C to 50 C: 0.5 C (uncalibrated typical)
0.025 C for 1 C changes within 15 C to 35 C
User selectable up to 0.001 C
0 % to 100 % RH
20 % to 70 % RH: +2 % RH (calibrated)
0 % to 20 % RH, 70 % to 100 % RH: 3 % RH
1.0 % for 5 % changes within 20 % to 70 % RH
User selectable up to 0.01 %
Up to two sensors, each measuring temperature and
relative humidity; remotable
LCD, displays data graphically, numerically and
statistically; 16 setups are included
400,000 typical individual time-stamped readings
Visual and audio alarms for temperature, temperature rate,
RH, RH rate, and fault conditions
RS-232 and IrDA
64 MB flash memory for downloading data to a PC
12 V dc from external 100-240 VAC power supply
0 C to 50 C
4.9 H x 8.3 W x 2.0 D in (125 x 211 x 51 mm)
1.5 lb. (0.7 kg)
Certificate of NIST-traceable calibration included
Software
Ordering information*
9938-16 MET/TEMP II
Software (package includes
CD-ROM, RS-232 emultiplxer
box, adapter, and PC cable),
(110 V)
9938 MET/TEMP II Software
(includes CD-ROM, RS-232 multiplexer, adapter, and PC cable),
(220 V)
9934-S LogWare,
Single channel, single user
9934-M LogWare,
Single channel, multi-user
9935-S LogWare II,
Multi-channel, single user
9935-M LogWare II,
Multi-channel, multi user
* Requires Windows 98 or
higher
37
Multi-channel LogWare II
Optional Probes
Summary specifications
38
Model
Readout
Type
Range
Size
Cal Uncertainty
and Short-Term
Stability
0.007C at 0 C
Typical
Drift
(1 Year)
< 0.03 C
5626-12-I
5626-12-D
5626-12-L
5614-12-I
5614-12-D
5614-12-L
5613-6-I
5613-6-D
5613-6-L
5612-9-I
5612-9-D
5612-9-L
5627-6-I
5627-6-D
5627-6-L
5627-9-I
5627-9-D
5627-9-L
5627-12-I
5627-12-D
5627-12-L
5618A-9-I
5618A-9-D
5618A-9-L
5622-05-I
5622-05-D
5622-05-L
5610-9-I
5610-9-L
5611-I
5611-L
1521 or
1502A
1529
1521 or
1502A
1529
1521 or
1502A
1529
1521 or
1502A
1529
1521 or
1502A
1529
1521 or
1502A
1529
1521 or
1502A
1529
1521 or
1502A
1529
1521 or
1502A
1529
1521 or
1529
1521 or
1529
1522
High-Temp PRT,
100 ohm
200 C to 661 C
(-328 F to 1221 F)
1/4 in x 12 in
(6.35 x 305 mm)
1522
Secondary PRT,
100 ohm
200 C to 420 C
(-328 F to 788 F)
1/4 in x 12 in
(6.35 x 305 mm)
0.018 C at 0 C
0.01 C
1522
Secondary PRT,
100 ohm
200 C to 300 C
(-328 F to 572 F)
3/16 in x 6 in
(4.76 x 152 mm)
0.018 C at 0 C
0.01 C
1522
Secondary PRT,
100 ohm
200 C to 420 C
(-328 F to 788 F)
3/16 in x 9 in
(4.76 x 229 mm)
0.018 C at 0 C
0.01 C
1522
200 C to 300 C
(-328 F to 572 F)
3/16 in x 6 in
(4.76 x 152 mm)
0.050 C at 0 C
0.13 C
1522
200 C to 420 C
(-328 F to 788 F)
3/16 in x 9 in
(4.76 x 229 mm)
0.050 C at 0 C
0.13 C
1522
200 C to 420 C
(-328 F to 788 F)
1/4 in x 12 in
(6.35 x 305 mm)
0.050 C at 0 C
0.13 C
1522
200 C to 500 C
(-328 F to 932 F)
1/8 in x 9 in
(3.2 x 229 mm)
0.050 C at 0 C
0.01 C
1522
Fast-response RTD
200 C to 350 C
(-328 F to 662 F)
0.02 in x 4 in
(0.5 x 100 mm)
1522
Thermistor,
Stainless
Thermistor, Bare
Silcone Bead
0 C to 100 C
(32 F to 212 F)
0 C to 100 C
(32 F to 212 F)
1/8 in x 9 in
(3.2 x 229 mm)
0.07 in x 0.55 in
(1.8 x 14 mm)
0.15 C at 0 C,
0.15 C
uncalibrated;
0.04 C, calibrated*
0.015 C at 0 C
0.01 C
1522
0.015 C at 0 C
0.01 C
*These probes do not come with an individual certificate if a calibration is not ordered separately. Order calibration 1923-4-N if needed, (186 C to 300 C)
Terminations: I = INFO-CON for 1521/1522; D = 5 pin din for 1502A; L = Mini spade lugs for 1529
Accessories
Fluke 700PMP
Fluke 700PTP
39
Fluke 700HTH
Fluke 87V/E
Fluke 700LTP
Accessories
Conversion factor: 10 mV = 1 mA
Accuracy (% of input, 1 year): 0.025 %
Input current: 0 to 55 mA
Input resistance: 250 nominal
Output resistance: 10 nominal Accuracy
specification applies from +18 C and 28 to 50 C
Maximum input voltage: 30 V dc
40
Battery pack
80PK-8
Accessories
Compatibility Chart
743B
741B
72X
744
700Pxx Pressure
Modules
BP7217 NiCd
Battery Pack
BP7235 NiMH
Battery Pack
BE9005 Battery
Eliminator
BC7217 Battery Charger
700BCW Bar Code Wand
700BCA Bar Code
Adapter
TPAK 80-4 ToolPak
LPAK 80-4 LockPak
700TC1 and TC2
Thermocouple Plug Kits
80CJ-M or 80CK-M
Mini-connectors
80PK Thermocouple
Probes (all)
700-IV Current Shunt
700ILF In-line Filter
700LTP Low-pressure
Test Pump
700PMP Pressure Pump
700PTP Pneumatic
Test Pump
700HTH Hydraulic
Test Hose
700HTP Hydraulic
Test Pump
80i-400 AC
Current Clamp
i410 AC/DC
Current Clamp
i1010 AC/DC
Current Clamp
C10 Holster, C12A Case
C25/C100 Cases
C781 Soft Carrying Case
C789 Soft Carrying Case
C700 Hard Carrying Case
C120/C125 Cases
C510 Leather Case
C530 Leather
Accessory Case
C550 Tool Bag
PV350 Pressure
Vacuum Module
Fiber Optic Meter FOM
717
712
714
724
715
707
705
78X
718
61
51/52
87V
65
53/54
189
43B
1. 20 amps ac minimum 2. External pump required only when using high pressure modules
41
Application
Assistance
Process tools technical notes and application notes can be obtained from
www.fluke.com/processtools. Or contact your local Fluke sales organization
(in the United States, call 1-800-44-FLUKE).
1. Understanding specifications for process calibrators
(Literature code 1261947)
Selection of a calibrator is
often based on a specification sheet. This application
note helps interpret and
compare performance specifications typically used for
process calibrators.
2. Transmitter calibration
(Literature code 1262393)
Step-by-step instructions
on how to calibrate analog
temperature and pressure
transmitters quickly and
effectively using the Fluke
740 Series Documenting
Process Calibrator.
1.
2.
42
3.
3. HART transmitter
calibration
(Literature code 1262439)
The need for calibration of
HART smart transmitters is
often misunderstood. What
do you calibrate and when?
Here is a step-by-step procedure showing how to use the
Fluke 744 to perform calibration and digital adjustments
of Rosemount 3051 and 3144
transmitters and other HART
devices.
4. Limit switches
(Literature code 1263879)
Verifying the exact temperature or pressure applied to a
limit switch at its trip point
can be hard to determine.
Learn how the Fluke 740
Series Calibrators help solve
this measurement problem.
5. Custom units and
user entered values
(Literature code 1263925)
This note demonstrates how
to document local temperature indicators and pressure
gauges in the field with a
Fluke 740 Series Calibrator.
4.
6. Pressure Calibration
(Literature code 1281620)
Examples of how to calibrate,
troubleshoot and verify the
most common pressure
devices and the Fluke
tools that address these
applications are shown.
7. Temperature calibration
(Literature code 1560369)
Examples of how to calibrate,
troubleshoot and verify the
most common temperature
devices and the Fluke
tools that address these
applications are shown.
8. Loop calibration
and maintenance
(Literature code 1627722)
Loop calibrators are a
versatile tool for maintaining
4-20 mA control loops. This
note demonstrates how to
use the Fluke 707, 787, 715
and 705 to perform several
day-to-day tasks.
5.
9. Troubleshooting
12. How to select a dry-well
process loops
(Literature code 2088282)
(Literature code 1989137)
If you use industrial temperaIn process systems, problems
ture sensors such as RTDs,
with the loop can bring
thermocouples or thermistors,
things to a screeching halt.
then you need a dry-well
In this application note, find
calibrator that is capable
out how to use Fluke test
of precision temperature
tools to identify current loop
calibration.
problems such as noise,
13. Eliminating sensor errors in
ripple and drift.
loop calibrations
10. Calibrating a pressure
(Literature code 2148146)
Learn how to adjust for
switch with a DPC
sensor errors in your loop
(Literature code 2069058)
calibrations using dry-wells
Learn how to use a Fluke 740
and a Fluke 744.
Series Documenting Process
Calibrator to easily calibrate
and document the performance of pressure switches.
11. Dry-well calibrators:
application and selection
(Literature code 2088275)
Learn the elements that make
a dry-well calibrator an ideal
calibration tool for industrial
sensors.
13.
43
6.
7.
10.
8.
9.
11.
12.
www.fluke.com/hartscientific