Sie sind auf Seite 1von 8

Fluke Process Tools

Accessories
Technical Data

Pressure Pumps
Fluke 700PTP
Pneumatic Test Pump

Use Fluke
accessories
to enhance
the power
of your Fluke
Process
Calibrators

For use with: Fluke 700 Series


Pressure Modules and the Fluke
710 Series Pressure Calibrators.
Description: The Fluke 700PTP
is a handheld pressure pump
designed to generate either
vacuum to -11.6 psi/-0.8 bar
or pressure to 360 psi/25 bar.
The Fluke 700PTP has two
pressure ports:
3/8-BSP (ISO228) female
parallel thread fitting for the
reference gauge or pressure
module
1/8-BSP (ISO228) female
parallel thread fitting for the
unit under test

Application: The Fluke 700PTP


features an integral pressure
adjustment vernier which varies
the pressurized volume by
2.0 cc over approximately
eleven turns of the vernier
knob. The pressure variation
achievable with the vernier will
depend on the nominal pressure
and total pressurized volume,
but with a minimum volume
and maximum pressure, the
vernier provided 360 20 psi
adjustment range. With a minimum volume and no pressure
applied, the vernier can also
be used to provide a 0 to 70"
H2O range. Larger volumes will
provide a smaller range of adjustment, but greater resolution.
The length of the stroke can be
adjusted to limit the maximum
output pressure. Maximum output pressure is adjustable from
2.5 psi to 360 psi.

Included:
1. Adapter to connect the
reference gauge port on the
pump body to the 1/4 NPT
male fitting on Fluke 700Pxx
Pressure Modules (except
700P29, P30, and P31)
2. One-meter nylon hose to
attach to unit under test port
to the unit under test. The
hose terminates in a 1/4-BSP
(ISO228) female parallel
thread fitting
3. Adapter to convert the 1/4BSP female parallel thread
fitting to a 1/4 NPT female
4. Replacement seal kit
(689331)
5. Instruction sheet
Material: Nickel plated brass/
anodized aluminum
Dimensions: 8.7" x 4.1" x 2.5"
(220 mm x 105 mm x 63 mm)
Weight: 1.4 lb (0.65 kg)
Warranty: One year

Fluke 700HTP
Hydraulic Test Pump
For use with: Fluke 700 Series
Pressure Modules and the Fluke
710 Series Pressure Calibrators.
Description: The Fluke 700HTP
is designed to generate pressures up to 10,000 psi/700 bar.
The Fluke 700HTP has two
pressure ports:
3/8-BSP (ISO228) female
parallel thread fitting for the
reference gauge or pressure
module
1/8-BSP (ISO228) female
parallel thread fitting for the
unit under test
Fluke 700PTP

Fluke 700HTP

Note: The user must provide a hose with


appropriate end fittings from this port to
the unit under test.

Pressure Pumps

(continued)

Application: This pump can


provide up to 10,000 psi using
distilled water or mineral-based
hydraulic oil. The pump is operated by pumping several strokes
to prime the system, then
switching to high pressure
mode when the resistance
increases. An integral pressure
adjustment vernier knob varies
the pressurized volume by
0.6 cc. The pressure variation
achievable with the vernier will
depend on the nominal pressure
and total pressurized volume,
but with a minimum volume,
the vernier provided 150-3,000
psi (at 150 psi nominal) and
3,000-10,000 psi (at 3,000 psi
nominal) adjustment ranges.
With a minimum volume and
no pressure applied, the vernier
can also be used to provide a
0 to 1.7 psi range. Larger
volumes will provide a smaller
range of adjustment, but greater
resolution.
Included:
1. Adapter to connect the
reference gauge port on the
pump body to the 1/4 NPT
male fitting on Fluke 700Pxx
Pressure Modules (except
700P29, P30, and P31)
2. Adapter to connect the
reference gauge port on the
pump body to the 1/4 NPT
female fitting on the Fluke
700P29, P30, and P31
Pressure Modules
3. Adapter to convert the unit
under test port to a 1/4 NPT
female
4. Replacement seal kit (689361)
5. Instruction sheet
Material: Stainless steel
Dimensions: 9.3 x 6.3 x 2.8
(236 mm x 159 mm x 70 mm)
Weight: 3.5 lb/1.6 kg
Warranty: One year

Fluke pressure modules from


damage due to accidental
over-pressurization. 1/4 BSP
male parallel thread to fit
Fluke 700HTP.
Application: Repeatability
10% of nominal setting. Multiturn adjustment screw to set
preload on internal disc springs.
Included: The 700PRV contains
two relief valves.
One adjustable from
725-2900 psi/50-200 bar
(preset at 1360 psi/94 bar)
One adjustable from
2900-5800 psi/200-400 bar
(preset at 5450 psi/376 bar)
Instruction sheet
Material: Type 303 stainless
steel
Dimensions: 1.57 L x .87
diameter (40 mm x 22 mm)
Weight: 0.13 lb/60g per relief
valve
Warranty: One year

tion unit under test from a Fluke


700HTP hydraulic test pump in
use with the Fluke 700 series
pressure modules. The 700HTH
is compatible with water and
non-corrosive oil.
Included: Hose and fittings to
connect directly to the Fluke
700HTP test pressure port. Output connection is 1/4 NPT female with adapters (2) to convert to1/4 and 1/8 NPT male.
Instruction sheet
Material: Nylon, stainless steel,
brass, PFTE, nitrile
Dimensions: Length 1 meter,
bore 0.3/3.2 mm, outer diameter 0.27/6.9 mm
Weight: 2.2 lbs./1.0kg
Warranty: One year

Fluke 700HTH

Fluke 700LTP

Fluke 700LTP
Low-pressure Test Pump

For use with: Fluke 700 Series


Pressure Modules and the 710
Series Pressure Calibrators
Description: The Fluke LTP is a
Fluke 700HTH
hand operated pressure pump
Hydraulic Test Hose
designed to generate either
vacuum to -12 psi/-.85 bar or
For use with: Fluke 700 HTP
pressures to 30 psi/2000 mbar.
Hydraulic Test Pump.
Description: The Fluke 700HTH The Fluke 700 LTP has two
pressure ports with push fit
hydraulic test hose is a 10,000
connectors. These push fit conpsi, 700 bar working pressure
test hose that features stainless nectors, one for the reference
port for connection to a Fluke
steel and nylon construction.
700 series pressure module and
The hose uses self-sealing fitone to connect to a unit under
tings with easy finger tight
connections. The hose has very test, connect to the supplied test
low volumetric expansion and a hoses. These test hoses are
terminated with 1/4-BSP
negligible pressure drop at
(ISO228) female parallel thread
rated pressures.
Application: The Fluke 700HTH fittings that can be adapted
using the fittings included.
allows connection to a calibra-

Fluke 700PRV
Pressure Relief Valve Kit
For use with: Fluke 700HTP
Hydraulic Test Pump.
Description: The Fluke 700PRV
consists of two relief valves
(1360 and 5450 psi) to be used
with the 700HTP Hydraulic Test
Pump. These relief valves will
protect the most commonly used

Fluke Corporation Process Tools Accessories

Pressure and Calibration Accessories


Application: The Fluke 700LTP
is primarily intended for low
pressure applications. It features
a fine adjust vernier with
.00145/limbar resolution at low
pressures. The pressure variation achievable with the vernier
will depend on the nominal
pressure and total pressurized
volume, but with minimum volume and maximum pressure the
vernier provides 30 psi +/- 6
psi. The adjustable pressure
relief valve features a slowbleed capability that allows the
user to slowly release pressure
at a controlled rate to achieve a
desired pressure.
Included:
1. Adapter to convert the
reference port hose fitting
to 1/4 ISO tapered female
2. Adapter to convert the reference port hose fitting to
1/4 NPT female for connection to 700 series pressure
modules (2 included)
3. One 1/4 NPT male to 1/8 NPT
male adapter

4. One seal kit


5. Instruction sheet in English
Material: Bright nickel plated
brass, clear anodized aluminum
Dimension: 6.7 x 1.8, 150
mm x 46 mm
Weight: 1.3 lbs./600g
Warranty: One year

Fluke 700ILF In-line Filter


For use with: Fluke 717 and
718 Pressure Calibrators
Description: Use to isolate
calibrator from contact with
liquids. Input is 1/8 NPT female. Output is 1/8 NPT Male.
Application: The Fluke 700ILF
can be used to isolate the calibrator from incidental contact
with fluids present in the gas
medium being measured. Particularly useful with the 718
calibrator to help keep moisture
or oils from contaminating the
on-board pump. The 1/8 NPT
male threaded output threads
directly into the 717 and 718
calibrators. Maximum pressure
is 100 psi. Burst pressure is

29 Pressure Modules
Fluke offers a family of 29
Pressure Modules to address
gage, differential, absolute,
vacuum, and dual (compound)
applications to 10,000 psi/700
bar.
For detailed specifications
and applications, ask for
Application Note 1281620.

375 psi. Maximum flow is 10


SCFM and filtration to 1 micron.
Included: One disposable filter
Dimensions: 2.125 x 1.875
Weight: 4.1 oz./115g

Fluke 700PCK
Pressure Calibration Kit
Pressure
Calibrator

Pressure
Module

Interface
Unit

Line Power

PC Serial Port
8

For use with: Fluke 700 Series


Pressure Modules.
Description: The Fluke 700PCK
makes it possible to calibrate
your pressure modules at your
facility using your own precision pressure standards.
Application: When installed on
your PC, the Windows -based
software easily steps you
through an as-found verification, a calibration adjustment,
and an as-left verification.
Calibration data is captured for
import to your database. A 386
or better PC running Windows
3.1 or better is required, along
with a precision pressure standard with an uncertainty of less
than 1/4 that of the pressure
module being verified.
Included: The kit consists of
a power supply, an interface
adapter, appropriate cables, and
Fluke 700PC Pressure Module
Calibration Software.
Warranty: One year

Fluke 700PCK

Process Tools Accessories Fluke Corporation

Calibration and Process Calibrator Accessories


Fluke 787CAL
Calibration Module
For use with: Fluke 787
ProcessMeter and MET/CAL
Software, version 6.0.
Description: The Fluke 787CAL
module permits users and service facilities to perform automated MET/CAL verifications
and calibrations of the Fluke
787 ProcessMeter.
Application: The calibration
module provides a 9 volt dc
supply to the 787. At the same
time, it facilitates RS232 communication from the PC running
MET/CAL to the 787 over the
battery leads of the 787.
Included: A calibration manual,
MET/CAL procedures, and an
interface module that permits
serial communication between
a 787 and a PC.
Note: An installation of MET/CAL Calibration
Software plus appropriate calibration
equipment must be provided by the user.
Required Calibration Equipment for use with
the Fluke 787CAL Calibration Accessory:
Fluke Model 5500 or 5520 Calibrator
HP3458 DMM or **HP34401 DMM,
Fluke 5440A-7002 Test Lead set
Fluke RS43 Null Modem Cable
Personal Computer, 486 or better,
IBM compatible
Fluke MET/CAL Calibration Software,
Version 6.0 or later
**HP34401 for use only with 5520A only
5500A requires HP3458 DMM

Fluke 700-IV
Current Shunt
For use with: Fluke 701, 702,
and 740 Series Documenting
Process Calibrators.

Fluke 700-IV

Fluke Corporation Process Tools Accessories

Description
Conversion factor: 10 mV = 1 mA
Accuracy (% of input, 1 year):
0.025%
Input current: 0 to 55 mA
Input resistance: 250, nominal
Output resistance: 10, nominal
Accuracy specification applies
from +18C and 28-50C
Maximum input voltage: 30V dc
Application: Use the Fluke 700IV Current Shunt to calibrate
and troubleshoot mA/mA
devices. On a 741 or 743
Documenting Process Calibrator,
Source mA and Measure V dc.
The custom units function of
the calibrator automatically
provides the correct conversion,
and directly displays/captures
the current in mA.
Included: Shunt, instruction
sheet.
Warranty: One year

in ambient light to 100,00 lux.


EMI compliance per FCC part 15
Class B. ESD immunity, 25 kV.
Application: Supports the
scanned entry of procedure
identification, tag ID, serial
number, and operator ID to a
Fluke 743 Documenting Process
Calibrator.
Included: Bar code wand with
integrated decoding circuity,
holder, and users manual;
a Fluke 700BCA Bar Code
Adapter, and instruction sheet
in English, French, German,
Italian, and Spanish.
Material: Polycarbonate wand,
sapphire tip.
Dimensions: 6.3 L x 0.9
diameter (160 mm x 23 mm).
Coiled cable extends to
approximately 100 (2.5m).
Weight: 6 oz/160g
Warranty: One year

Fluke 700BCW
Bar Code Wand

Fluke 700BCA
Bar Code Adapter

For use with: Fluke 743


Documenting Process Calibrator.
Description: This Hewlett
Packard HBSW-8200 Bar Code
Wand reads eight common bar
code symbologies. Code 39,
Interleave 2 or 5, UPC A and E,
EAN 8 and 13, Codabar, Code
128, Code 11, Code 93, and MSI
Code. Programmable via bar
code labels or escape sequences. LED indicates when a bar
code has been correctly decoded. Resolution, 0.0075 (.19
mm). Usable from -20 to 65C,

For use with: Fluke 743 Documenting Process Calibrator.


Description: Shielded four
conductor cable terminated with
a 9-socket D-subminiature
connector and a 9-pin D-subminiature connector.
Application: Provides interconnection and pin translation
between a Fluke 743 Documenting Process Calibrator and
a Hewlett Packard HBSW-8200
Bar Code Wand.
Included: Interface cable,
(calibrator to bar code wand),

Fluke 700BCW

and instruction sheet inEnglish,


French, German, Italian, and
Spanish.
Material: Black PVC cable and
housings, tin plated shells, gold
plated copper contacts.
Dimensions: Overall length
approximately 6 (15 cm)
Warranty: One year

Fluke 700TC2
Thermocouple Mini-Plug
Kit Type J, K, T, E, R/S

For use with: Fluke 700 or 740


Series Documenting Process
Calibrators, Fluke 714 Thermocouple Thermometer.
Description: A kit of seven
mini-plug connectors supporting
six of the most popular thermoFluke 700TC1
Thermocouple Mini-Plug couple types.
Application: Terminate userKit (11 types)
supplied thermocouple wire to
For use with: Fluke 700 or
permit connection to process
740 Series Documenting Process calibrator.
Calibrators, Fluke 714 ThermoIncluded mini plugs
couple Thermometer.
Type J (black), two
Description: A kit of 10 miniType K (yellow), two
plug connectors supporting each Type T (blue), one
of the thermocouple types sup- Type E (purple), one
ported by the Fluke 700 or 740 Type R/S (green), one
Series Documenting Process
Material: Thermoplastic plug
Calibrators.
bodies; contacts of appropriate
Application: Terminate userthermocouple metallurgy.
supplied thermocouple wire to
Warranty: One year
permit connection to a process
calibrator.
BP7217
Included mini plugs
Ni-Cd Battery Pack
Type J (black), one
For use with: Fluke 700 or
Type K (yellow), one
740 Series Documenting
Type T (blue), one
Process Calibrators.
Type E (purple), one
Description: 7.2V 1700 mA-hour
Type R/S (green), one
rechargeable Ni-Cd battery pack.
Type B or Cu (white), one
Application: Provides typical
Type L (J-DIN) (blue), one
8-hour battery life when used
Type U (T-DIN) (brown), one
in 700 or 740 Calibrators.
Type C (red), one
Included: One battery pack.
Type N (orange), one
Material: Six 1.2V dc Ni-Cd
Material: Thermoplastic plug
cells in custom-molded ABS/
bodies; contacts of appropriate
PC-blend case.
thermocouple metallurgy.
Warranty: One year

Dimensions: 7.1 x 2.2 x .9


(150 mm x 56 mm x 22 mm)
Weight: 11 oz/310g
Warranty: One year

BP7235
NiMH Battery Pack
For use with: Fluke 700 or
740 Series Documenting Process
Calibrators, requires BC7217
charger
Description: 7.2 V 3500 mAhour rechargeable NiMH battery
pack.
Application: Provides typical
16 hour battery life when used
in 700 or 740 calibrators.
Included: One battery pack
Material: Six 1.2 V dc NiMH
cells in custom-molded ABS/
PC-blend case
Dimensions: 7.1 x 2.2 x 0.9
(150 mm x 56 mm x 22 mm)
Weight: 11 oz./310g
Warranty: One year

Fluke BP7217

Fluke BP7235

Fluke 700TC1

Fluke 700TC2

Process Tools Accessories Fluke Corporation

Process Calibrator Accessories (continued)


BE9005 120
Battery Eliminator

BE9005 220
Battery Eliminator

BC7217
Battery Charger

For use with: Fluke 700 or


740 Series Documenting
Process Calibrators.
Description: 7.5V dc battery
eliminator for operation of
calibrator from 120 volt ac line.
UL/CSA recognized.
Application: For use in North
America; 120V ac 60 Hz lines.
Dimensions: 3.8" x 2.5" x 2.2"
(96 mm x 63 mm x 56 mm);
72" (1.8m) cord
Weight: 1 lb/0.5 kg
Warranty: One year

For use with: Fluke 700 or


740 Series Documenting
Process Calibrators.
Description: 7.5V dc battery
eliminator for operation of
calibrator from 230 volt ac line;
VDE and/or TV approved.
Application: CEE-7 input connector, used primarily in continental Europe; 230V ac 50 Hz
lines.
Dimensions: 3.8" x 2.5" x 1.9"
(96 mm x 63 mm x 48 mm);
72" (1.8m) cord
Weight: 1 lb/0.5 kg
Warranty: One year

For use with: BP7217 NiCd and


BP7235 NiMH Battery Packs.
Description: Battery charger UL,
CSA, MITI, DEMKO, FINKO,
SEMKO recognized.
CE compliant. EMI per FCC
part 15 Class B.
Application: Replaces BC7210
Battery Charger. Select 120 volt
version for use in North America.
Select INTL version for use
outside of North America. Line
voltage 100 to 250V ac, frequency 50 to 60 Hz. IEC 320
inlet, lne cord will be provided
based on country of destination.
Included: Battery charger base,
power supply.
Dimensions:
Power supply: 3.9" x 2.6" x 1.6"
(100 mm x 66 mm x 41 mm;
72" (1.8m) cord
Charger base: 4.6" x 4.1" x 2.7"
(116 mm x 104 mm x 58 mm)
Weight: 1.7 lb/0.78 kg
Warranty: One year

BE9005 240
Battery Eliminator
For use with: Fluke 700 or
740 Series Documenting
Process Calibrators.
Description: 7.5V dc battery
eliminator for operation of
calibrator from 230 volt ac line.
BABT approved.
Application: BS-1363 input
plug, used primarily in UK,
China, and Hong Kong; 230V ac
50 Hz lines.
Dimensions: 3.8" x 2.5" x 2.3"
(96 mm x 63 mm x 58 mm);
72" (1.8m) cord
Weight: 1 lb/0.5 kg
Warranty: One year

Fluke BE9005 120

Fluke Corporation Process Tools Accessories

Fluke BE9005 220

Fluke BE9005 240

C700 Hard Carrying Case


(700 Series)
For use with: Fluke 700 or
740 Series Documenting
Process Calibrators.
Description: Hard carrying case
with custom-cut foam liner.
Application: Cutouts to hold
one documenting process
calibrator, one Fluke Pressure
Module, one BC7210 Battery
Charger, one spare BP7217
Battery Pack, and test leads.
Material: Exterior: Blow-molded
charcoal gray polyethylene with
textured surface. Interior: Black,
die-cut polyurethane foam.
Handle: Molded polyethylene.
Latches: Zinc-plated steel.
Dimensions: 18.5" x 15.6" x 5.0"
(47 cm x 40 cm x 14 cm)
Weight: 2 lb/0.9 kg
Warranty: One year

BC7217

C781 Soft Carrying Case

C789 Soft Carrying Case

For use with: Fluke 700 or


740 Series Documenting Process
Calibrators. Also fits DSP-100
CableMeter or DSP-200
CableAnalyzer and Fluke 860
Series Graphical Multimeters.
Description: Rugged, closefitting fabric carrying case for
documenting process calibrator.
A separate, detachable pouch
holds test leads and accessories.
Application: Designed to be
worn on a belt. Remove the
calibrator from the C781 for use.
Material: Black woven nylon,
black vinyl, with yellow Fluke
logo panel.
Dimensions:
Primary compartment:
10.3" x 5.6" x 1.8"
(26 cm x 14 cm x 5 cm).
Detachable accessory pouch:
7.5" x 5.6" x 1.0"
(19 cm x 14 cm x 3 cm)
Weight: 8 oz/230g
Warranty: One year

For use with: Fluke 701, 702,


and 740 Series Documenting
Process Calibrators. Also fits
DSP-100 CableMeter or
DSP-200 CableAnalyzer and
Fluke 860 Series Graphical
Multimeters.
Description: Rugged, threecompartment fabric carrying
case for documenting process
calibrator and accessories. Center zippered compartment holds
the calibrator, while zippered
side compartments are suitable
for leads, pressure modules, or
spare batteries. A flat pocket on
the back surface is ideal for a
manual or notebook.
Application: Front access flat
allows the calibrator to be used
while in the C789 Case.
Designed to be carried over
one shoulder.
Included: Case, detachable
handle, and detachable
shoulder strap.
Material: Black woven nylon,
black vinyl, with yellow Fluke
logo panels.
Dimensions: 11.8" x 10.0" x 3.3"
(30 cm x 25 cm x 8 cm)
Weight: 1.5 lb/700g
Warranty: One year

Fluke C789, C700, C781

Process Tools Accessories Fluke Corporation

General-Purpose Accessories
743B/ 741B
744
Fluke 700Pxx Pressure Modules 1
BP7217 NiCd Battery Pack
BP7235 NiMH Battery Pack
BE9005 Battery Eliminator
BC7217 Battery Charger
Fluke 700BCW Bar Code Wand
Fluke 700BCA Bar Code Adapter
Fluke 700TCI and TC2 Thermocouple Plug Kits
80CJ-M and 80CK-M Mini-Connectors
80PK Thermocouple Probes (all)
Fluke 700-IV Current Shunt
Fluke 700PMP Pressure Pump
Fluke 700PTP Pneumatic Test Pump
Fluke 700HTP Hydraulic Test Pump
Fluke 700LTP Low Pressure Test Pump

712

714

715

717

80PK-IR Infrared Probe


80TK Thermocouple Module
80T-150U Universal Temperature Probe
TL20/22/24/26/28 Lead Sets
TL70A and Y8140A Lead Sets
AC20 and AC80 Clips
TP20 Industrial Test Probes
80i-400 AC Current Clamp
i410 AC/DC Current Clamp
i1010 AC/DC Current Clamp

87

51/52

16

123

Fluke 787CAL Calibration Kit


80T-IR Infrared Probe

787

3
3

3
3

C10 Holster and C12A Case

C25/C28/C90/C100/C800 Cases
C781 Soft Carrying Case
C789 Soft Carrying Case
C700 Hard Carrying Case

83RF and 85RF High Frequency Probes


PV350 Pressure Vacuum Module
Fiber Optic Meter (FOM)

C120 and C125 Case


80K-6 and 80K-40 High Voltage Probes

Ask for Application Note 1281620


DC current only
3 20A ac minimum
2

Fluke. Keeping your world


up and running.

Fluke Corporation
PO Box 9090, Everett, WA USA 98206
Fluke Europe B.V.
PO Box 1186, 5602 BD, Eindhoven, The Netherlands
For more information call:
U.S.A. (800) 443-5853 or Fax (425) 446-5116
Europe (31 40) 2 675 200 or Fax (31 40) 2 675 222
Canada (800)-36-FLUKE or Fax (905) 890-6866
Other countries (425) 446-5500 or Fax (425) 446-5116
Internet: http://www.fluke.com
2002 Fluke Corporation. All rights reserved.
Printed in U.S.A. 5/2002 1265833 C-ENG-N Rev C
Printed on recycled paper.