Bars G2 (evenly spaced)

Backfill

Bars F
4" Min.
Bars A (F.S.)

Front Face
of Wall
Bars A (paired with Bars J)
Wall Cover
(Typ.)

H eight

H eight

Bars F (N.S.)

Bars G2 (evenly
spaced)
Slope

NOTE:

Backwall

See Plans for Retaining Wall Data

Bars J & K
Bars K (F.S.)
D
soil
(1-0" Min.)

Const. Jt.
L

Bars H
toe
Footing Cover (Typ.)

Bars J (F.S.)

Bars M (N.S.)

*D
key

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06010-1of2.
dgn

*D
key

A
Bars Z (N.S.)

Bars H

Bars G1

Bars G1

(Showing Near Side)

Bars Z

(Showing Far Side)

L
toe

Footing Cover (bottom only)

*L
key

Bars M (paired with Bars F)

L
foot

VIEW A-A
(Shear key shown dashed)
* Shear Key is required only when
specified by the Engineer

TYPICAL SECTION
NOTES

DESIGN SPECIFICATIONS:

BENDING DIAGRAM

Design according to FDOT Structures Manual (current edition).

MATERIALS:

Total Length

All reinforcing steel shall conform to ASTM A615 Grade 60.


1-0" Lap Splice (Typ.)

SURFACE FINISH:
A Class 5 Applied Finish Coating shall be applied to the top of the wall and the exposed face above ground line.

ARCHITECTURAL SURFACE TEXTURES:

BARS G1

Alternate Architectural Surface Textures may be substituted for the Striated Pattern shown when approved by the Engineer.
Concrete required for Architectural Surface Textures is not included in the quantities.

TRAFFIC RAILING BARRIER:

rd960rh

and Barrier Open Joints shall align.

If there is a Traffic Railing Barrier on the wall, Wall Joints and Barrier V-Grooves shall align and Wall Expansion Joints
Slope
Backwall
A

FOUNDATION: Prepare the soil below the footing in accordance with the requirements for spread footings in Specification

90

Section 455.

9:
34:
41 AM

PAYMENT:
All Retaining Wall costs, including all miscellaneous costs, shall be paid for at the unit contract price for

either Class II, III or IV Concrete (Retaining Walls) (CY) and Reinforcing Steel (Retaining Walls) (lbs.).
Retaining Wall quantities shall not include concrete nor reinforcing steel for Traffic Railings/Junction Slab.

12/30/2011

Traffic Railing/Junction Slab shall be paid for under Concrete Traffic Railing Barrier with Junction Slab.

BARS J & K

BARS M
NOTE:

LAST
REVISION

01/01/11

REVISIO N

All bar dimensions are out-to-out

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

C-I-P CANTILEVER RETAINING WALL

NO.

6010

SHEET
NO.

**Wall joint spacing 25 ft. maximum.


At minimum, every fourth wall joint
to be an expansion joint.

**Wall Joint Spacing

" V-Groove across top and

See Plans for actual wall joint spacing

" x " chamfers (

front face of wall at joint (Typ.).

and expansion joint location.

Extend V-Groove down back of wall

6"

to 6" min. below ground.

shall receive a Class 5

6"

All exposed wall surfaces

(see V-Groove Detail)

Applied Finish Coating

" V-Gr
(see V-Groove Detail)

Wall Joint

(required at footing step)

Thickness of form liner


(including striations)

Ground Line
6"

(keyway not required)

consist of uniform vertical

" V-Gr
6"

grooves of " t
See Detail A

At Contractors option,

See Typical Backfill Detail

6"

1-0"

(see V-Groove

depth and spacing

Detail)
D

10 ft. max. spacing (Typ.)

(including striations)

Striated Surface shall


3" PVC Drain Pipe at

step

Thickness of form liner

Level (Typ.)

Top of Footing

Const. Joint permitted

Top of Footing

SECTION A-A

(
2
-0" M ax.
)

6"

Striations may terminate at


6" min. below ground line

Traffic Railing (Index No. 420,


32" F-Shape shown, see Plans

Wall Joint

Stem Offset

(paired with

for Traffic Railing type)

Bars G1)

Junction Slab (See

Vertical Line

Index Series 6100)

Top of

DETAIL A

SECTION B-B

Front Face

CIP Wall

of Wall

-3"
9" 1

45 (Typ.)

Stem Offset (in.) = H(Ft.)/16


H

Wall

Front Face

of Wall

6"

1 b"

" V-Groove (T
4"

Bars D @ 1-0"
9
"

(see V-Groove Detail)

(Max. spacing)
4"

STEM OFFSET VALUES


*

V-GROOVE DETAIL

Front Face
of Wall

( for H < 20 Ft.)

TRAFFIC RAILING/JUNCTION SLAB DETAIL

Varies

Backfill layers to be sloped both

for 32" Vertical Shape Traffic Railing, see Index No. 423;

transversely and longitudinally as

for 42" Vertical Shape Traffic Railing, see Index No. 422)

necessary to drain and prevent

See Roadway Plans for

Backfilling shall comply with

drainage requirement

FDOT Specifications.

(field bend)

TYPICAL CORNER JOINT DETAIL


WALL JOINT DETAIL

ponding during backfilling.


Front Face of Wall

9"

Bars D

s
ie
r
a
V

(32" F-Shape Shown, other Traffic Railings similar)


(for 32" F-Shape Traffic Railing (as shown), see Index No. 420;

Varies

H eight Varies

Stem as constructed

"
4

*Key to stop at top of footing and 6" from top of wall.


Joint across footing and top of wall to be straight line.

3" PVC Drain Pipe. Slope down


b" from back to front of wall

Wall

Front Face

and extend b" beyond both

1 b"

of Wall

front face and back face of wall.

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06010-2of2.
dgn

Top of Coping

Optional Shear Key

Bars R

FRONT ELEVATION

b" Preformed Joint Filler


Bars D @ 1-0"
(Max. spacing)

Excavation shall comply with


*

FDOT Specifications.
Final Groundline.

4"

rd960rh

1" Cl.

Plastic sleeve

shall be covered with 1.0

Place geotextile fabric, meeting requirements of FDOT Specification

square foot of galvanized

985 and Type D-3 of Index No. 199, around the perimeter to

mesh with " open

prevent fill from washing out.

01/01/11

REVISIO N

LAST

9"

Geotextile fabric, 1-0" wide and full height of fill,


meeting requirements of Specification 985
and Type D-5 of Index No. 199.

EXPANSION JOINT DETAIL Apply

TYPICAL BACKFILL DETAIL

REVISION

Varies

graded and placed to allow free drainage.

12/30/2011

9:
34:
41 AM

Drain shall be continuous 1.5 x 1.5 clean, broken stone or gravel,


Inside ends of weep holes

an adhesive approved by the Engineer to

the back of wall for attachment of fabric material.

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

C-I-P CANTILEVER RETAINING WALL

NO.

6010

SHEET
NO.

lo
p
e
V
a
a
x
r
.
1 ie
:1 s

8"

(Typ.)

HEIGHT

8"

Varies

6"

3" Cl.

& DRAIN

Concrete for Scheme 3 Junction Slab and Traffic Railing shall

REQD.

be Class II per Section 346, unless otherwise specified in


the plans.

0.08

0.11 (0.20*)

0.03

3 (4*)

No

0.14

0.20 (0.32*)

0.09

4 (5*)

No

0.22

0.32 (0.47*)

0.29

5 (6*)

Yes

3. Reinforcing steel shall be ASTM A615, Grade 40 or 60

ASTM A497 Deformed Welded Wire Reinforcement (WWR) may be


substituted on an equal area basis. Do not increase bar/wire

(Typ.)

0.32

0.47 (0.65*)

0.43

6 (7*)

Yes

0.43

0.65 (0.85*)

0.60

7 (8*)

Yes

4. When required, for adjunct guiderail see the plans,


Index No. 870 or 880 as appropriate. For adjunct Type B

12

fence see Index No. 802.


5. Joint seal to be two layers of 30# smooth roofing paper

ESTIMATED QUANTITIES NOTES:

6"
)
p.
Ty
(

or Type D-5 geotextile fabric in accordance with Index


No. 199. Mop all contact surfaces of concrete and roofing

For Scheme 3 Junction Slab and Traffic Railing see the

paper or geotextile fabric with cut-back asphalt. Stop

referenced Design Standards for estimated quantities.

Bars A &

roofing paper or geotextile fabric 6" below top of wall).

B @ 1-6"

6. Provide a continuous 1x1 clean gravel or crushed rock

* Quantity for 2-0" Toe Depth in Scheme 2.

Ctrs. (Max.)

drain for wall heights 3 ft. and higher. Wrap drainage layer

Weep

as shown, with Type D-3 geotextile fabric in accordance

Hole
Depth)

with Index No. 199. Provide 8"x8" galvanized mesh with


(
Toe

4b"

of 30# Smooth

(LB.)

spacing for Grade 60 reinforcing steel or WWR.

Ground

1" Cl.

Varies

One layer

General Note 5)

1
-0"

(
Joint Seal, see

9"

M ax.

STEEL

2. Concrete for Gravity Wall shall be Class NS per Section 347.

provided at the max. spacings shown. ASTM A185 Smooth or

Bar A
Keyway

Bar B

SCHEME

as the reinforced concrete retaining wall.

HOLES

Varies
3" Cl.

SCHEME

4b"

Surface

SCHEME

Joint Seal
H eight (
5
-0" M ax.
)

General Note 5)

1
-0"

(
Joint Seal, see

3" Cl.

(
Typ.
)

9"

M ax.
1
-6" sp.

Bars B @

(
30M ax.
)

Bars A (Typ.)

WEEP

REINF.

(FT.)

(Typ.)

W all Joints equally spaced

CLASS NS CONCRETE (CY)

concrete retaining walls, except walls of proprietary


designs, shall have the same face texture and finish

PER LINEAR FOOT OF WALL

3"

" Cha

" V-

ESTIMATED QUANTITIES FOR WALL

Bars B

GENERAL NOTES
1. Gravity walls constructed as extensions of reinforced

Drainage Layer

spacing (When Drainage Layer required). Locate minimum

(See Note 6)

2-0" clear of wall joints.

Roofing Paper

7.
6" Cl. ( 2"

Prepare Foundation Per

Tolerance)

Spec. 455 (Spread Footings)

Cost of reinforcing steel, face texture, finish, joint seal,


drain pipes, drainage layer, galvanized mesh and geotextile
fabric to be included in the Contract Unit Price for Concrete
Class NS, Gravity Wall. Cost of concrete for Junction Slab in
Scheme 3, to be included in Contract Unit Price for Concrete

KEYWAY & WALL JOINT DETAIL

TYPICAL SECTION

(TOP VIEW)

Traffic Railing Barrier With Junction Slab. Adjunct railings or


fences to be paid for separately.

BILL OF REINFORCING STEEL

Edge of paved shoulder


1:1b < Slopes = 1:1
1:6 < Slopes = 1:1b

Edge of paved shoulder

Slopes = 1:6

SIZE

LENGTH

As Reqd.

As Reqd.

Traffic Railing (Index No. 420,


32" F-Shape shown, see Plans

3-6" = Offset < 7-3"

BAR BENDING DIAGRAM

3-6" = Offset < 6-6"

7-3" Min. offset

3b"

Scheme 3
Scheme 1 & 2

Live Load Limit

6-6" Min. offset


Live Load Limit

(See Plans)

with wall heights > 3,


then 2-0" Min.)

Slopes up

to Max. 1:1

to Max. 1:1

1-0" For Slopes = 1:1b


2-0" For Slopes > 1:1b
5
12

H eight

steeper than 1:2

Slopes up

(
5M ax.
)

(Except for slopes

H eight

1-0" Min. to SHW

(
5M ax.
)

Note 4

1-0" Min. to SHW


for Wall Height = 2-0"
2-0" Min. to SHW

H eight + Toe Depth - 9"

See General

Wall Joint spacing - 4"


Junction Slab (See

Top of

(29-8" Max.)

Index Series 6100)

Coping
1
-3"

when required

H eight (
5M ax.
)

Soil Reinforcement

Note 4

BAR A

9
9"

12

for Wall Height > 2-0"

1-0" Min.

.
R

See General

H eight + Toe Depth - 2


-0"

Slopes = 1:6

or face of curb

for Traffic Railing type)

or face of curb
1:6 < Slopes = 1:1b

3-6" Min. Offset

MARK

"
1

rd960rh

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06011-1of1.
dgn

(Typ.)

9:
34:
42 AM

" openings, at the inside end of the PVC Drain P


Provide 2" PVC Drain Pipe (Sch. 40) at 10 ft. max.

And PVC Drain

12
NOTES:

to SHW

BAR B

1. All bar dimensions are


out to out.

LAST
REVISION

01/01/11

REVISIO N

12/30/2011

1-0"

1-0" For Wall Height = 2-0"

SCHEME 1

SCHEME 2

(No Traffic Loading Effects)

(With Traffic Loading or Slopes > 1:1b)

2-0" For Wall Height > 2-0"

SCHEME 3

must be a minimum of 1-6".

(With Traffic Railing)

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

2. Lap splices for Bars A

C-I-P GRAVITY WALL

NO.

6011

SHEET
NO.

C-I-P Traffic Railing

NOTES

Limit of Class 5
Applied Finish Coating

SPECIFICATIONS:
1. General Specifications:
The Florida Department of Transportation "Standard Specifications for Road
and Bridge Construction", Current Edition and Supplements as Amended.
2. Design Specifications:
a. Florida Department of Transportation (FDOT) "Structures Design Guidelines",
Current Edition.
b. American Association of State Highway and Transportation Officials (AASHTO)
"LRFD Bridge Design Specifications", Current Edition.
c. AASHTO-AGC-ARTBA Task Force 27 (Ground Modification Techniques),
"Insitu Soil Improvement Techniques", January 1990.

9.

All exposed concrete surfaces will receive a Class 5 Applied Finish Coating

C-I-P Junction Slab

Top of

in accordance with Specification Section 400. Refer to Typical Section on


this sheet and the following notes for limits of applied finish:
a. The inside, backside and top of Traffic Railings and Pedestrian/Bicycle
Railings.

Concrete Coping

b. Exposed surfaces of coping on top of retaining wall. Other coatings,


colors or textures will be applied as required in the Wall Control
Drawings.
Soil Reinforcement (Typ.)

10. For concrete facing panel surface treatment, see Wall Control Drawings.
Extend surface treatment a minimum of 6" below final ground line.

Surface treatment when

DESIGN CRITERIA:

retaining wall, unless a method to protect the structure, acceptable to both

required (See Construction

1. Design is based on the assumption that the material contained within the

the Engineer and Wall Company, is proposed and approved in writing. The

Note 10)

reinforced soil volume, methods of construction and quality of prefabricated

portion of piles or drilled shafts extensions within the soil volume will be

materials are in accordance with Specification Section 548 and Chapter 3

wrapped with polyethylene sheeting in accordance with Specification

of the FDOT Structures Design Guidelines.

Section 459.
12. A structural extension of the connection of the retaining wall panel to soil
reinforcement will be used whenever necessary to avoid cutting or excessive
skewing (greater than 15) of the soil reinforcement around obstructions

of the Engineer of Record.


4. If there are manholes and/ or drop inlets present, design and analysis for both
internal and external stability shall be considered.

1-0" Min.

4-0" Min.

the factored bearing resistance of the foundation for that specific wall location.

stability design, including foundation and slope stability, is the responsibility

Limits of
Soil Volume

maximum factored bearing pressure shown for the wall does not exceed

3. The Wall Company is responsible for internal stability of the wall. External

Proposed Final
Ground Line

(i.e., piles, pipes, manholes, drop inlets, etc.).


13. Steps in leveling pads will occur at MSE Wall panel interfaces. Panels will not
cantilever more than 2" past the end of the upper tier leveling pad.
Top of

14. The top of the leveling pad or footing will be 2-0" minimum below final

Leveling Pad

ground line.

2-0" Min.

Elevation

15. Top of leveling pad elevations shown in the Wall Control Drawings are maximum
SOIL PARAMETERS:

elevations. The constructed leveling pad elevations may be deeper based on

1. See Wall Control Drawings for soil characteristics of foundation material to be

the panel layout shown in the shop drawings.

on the actual soil characteristics utilized at the site.

Concrete Leveling Pad

Concrete Facing Panels

TYPICAL MSE RETAINING WALL SECTION

than half the height of a standard panel.

WITH A TRAFFIC RAILING

17. Work this Index with Index 6100 & 6200 Series.

(Showing Limits of the Reinforced Soil Volume)


MATERIALS:

SHOP DRAWING REQUIREMENTS:

1. Concrete Class: See Wall Control Drawings.

See Specification Section 548 for shop drawing requirements.

2. See Specification Section 548 for material requirements.


3. For additional material requirements see the Wall Companys General Notes.
10-0" min. C.I.P. Coping

12-0" min. Precast Coping/Traffic Railing

CONSTRUCTION:
1. Walls will be constructed in accordance with Specification Section 548 and
the Wall Companys instructions.

12"

2-0"

2. For location and alignment of retaining walls, see Wall Control Drawings.

Coping

3. If present, consider in design and analysis and locate manholes and drop

Transition

6"
Top of Coping

inlets as shown on wall elevations.

FDOT MSE RETAINING WALL CLASSIFICATION TABLE

6. It is the Contractors responsibility to determine the location of any

Durability Requirements
Coping

needed during construction.

2
-3"

5. The Contractor is responsible for controlling water during storm events as

Coping

and anticipated long term and differential settlements.

2
-0"

strip/mesh length, factored bearing resistances, minimum wall embedment

Precast

4. Refer to Wall Control Drawings of individual walls for minimum reinforcement

Applicable

Concrete

FDOT Wall
Type *

Other Allowable FDOT Wall Types

Concrete

Pozzolan

Soil

Cover

Class

Additions?

Reinforcement

(in.)

for Panels

**

Type

2A

2B

2C

2D

2E

2F

guardrail posts behind retaining wall panels. Prior to placement of the top
layer of soil reinforcement, individual reinforcing strips/mesh may be

Type 2A

3"

skewed (15 maximum) to avoid the post locations if authorized by

b" Preformed

the Engineer. No cutting of soil reinforcement is allowed unless shown

Joint Filler

rd960rh

II

No

Metal

Type 2B

IV

No

Metal

IV

No

Metal

Yes

Metal

Provide Supplemental

Type 2C

the soil reinforcement due to installation of the guardrail will be repaired

#4 Bar with 3" concrete

Type 2D

IV

by the Contractor at the Contractors expense. Repair method will be

cover
Type 2E

IV

No

Plastic

Type 2F

IV

Yes

Plastic

If existing or future structures, pipes, foundations or guardrail posts


within the reinforced soil volume interfere with the normal placement of
soil reinforcement and specific directions have not been provided on the

ELEVATION VIEW OF
* See Data Table in Contract Plans.

COPING HEIGHT TRANSITION

plans, the Contractor will notify the Engineer to determine what course
of action shall be taken.
8.

on Shop Drawings and approved by the Engineer. Any damage done to

approved by the Engineer.


7.

9:
34:
46 AM

Interior Face of

16. The height of panels in the bottom course of MSE Walls must not be less

C.
I.
P.

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06020-1of1.
dgn

used in the design of the wall system.


2. The Contractor will provide soil design parameters for backfill material based

Roadway Pavement

6100)

11. Drive piles located within the soil volume prior to construction of the

2. It is the responsibility of the Engineer of Record to determine that the

Shoulder or

(See Index Series

Coping Elevation

(Railing Not Shown For Clarity)

** Silica fume, metakaolin or ultrafine fly ash.

The Contractor is responsible for gradually displacing upper layer(s) of


soil reinforcement downward (15 maximum from horizontal) to avoid
cutting soil reinforcement and conflicts with paving and subgrade preparation.
The Contractors attention is directed especially to situations where roadway

12/30/2011

superelevation and/or soil mixing are anticipated.

REVISION

01/01/12

REVISIO N

GENERAL NOTES AND DETAILS


LAST

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

PERMANENT MSE RETAINING WALL SYSTEMS

NO.

6020

SHEET
NO.

NOTES
SPECIFICATIONS:
1. General Specifications:
The Florida Department of Transportation "Standard Specifications for
Road and Bridge Construction", Current Edition and Supplements as
Amended.
Secondary Reinforcement

2. Design Specifications:
Top of Wall

a. Florida Department of Transportation (FDOT) "Structures Design

as required

Guidelines", Current Edition.


b. American Association of State Highway and Transportation Officials
(AASHTO) "LRFD Bridge Design Specifications", Current Edition.

Primary Reinforcement

c. AASHTO-AGC-ARTBA Task Force 27 (Ground Modification Techniques),


"Insitu Soil Improvement Techniques", January 1990.
Reinforced
Fill

DESIGN CRITERIA:
1. Design is based on the assumption that the material contained within the
reinforced soil volume, methods of construction and quality of prefabricated

Geotextile Wrap

materials are in accordance with Specification Section 548 and FDOT


Structures Design Guidelines Section 3.13.2.

Wire Facing

2. It is the responsibility of the Engineer to determine that the factored

Limits of

or Basket

Soil Volume

bearing pressure shown for the wall does not exceed the factored
bearing resistance of the foundation for that specific wall location.
3. The Wall Company is responsible for internal stability of the wall. External
stability design, including foundation and slope stability, is the responsibility
of the Engineer.

4"-0" Min.

4. If present, consider in design and analysis and locate manholes and drop
inlets as shown on wall elevations.

1"-0" Min.
Foundation Soil

SOIL PARAMETERS:

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06030-1of1.
dgn

1. See wall control drawings for soil characteristics of foundation material


Soil Reinforcement Length

to be used in the design of the wall system. The Contractor must provide
soil design parameters for backfill material based on the actual soil
characteristics utilized at the site.

Provide the values of unit weight,

TYPICAL RETAINING WALL SECTION

cohesion and internal friction angle in the Shop Drawings.

(Showing Limits of the Reinforced Soil Volume)


MATERIALS:
1.

Provide soil reinforcement in accordance with Specification Section 548.

2.

For additional material notes, see Wall Company General Notes.

CONSTRUCTION:
1.

Walls must be constructed in accordance with Specification Section 548 and


the Wall Companys instructions.

2.

For location and alignment of retaining walls, see Wall Control Drawings.

3.

Refer to Plan and Elevation sheets of individual walls for minimum

Varies (See Index No. 414


2-0" Min.

and Wall Control Drawings)

reinforcement strip/mesh length, factored bearing resistances, minimum


wall embedment and anticipated long term and differential settlements.
4.

Type K Temporary

If existing or future structures, pipes, foundations or guardrail posts within

Traffic Railing

the reinforced soil volume interfere with the normal placement of soil
Dropoff

reinforcement and specific directions have not been provided on the

(See Index No. 414


for Details)

plans, the Contractor must notify the Engineer to determine what course
of action should be taken.
5.

The Contractor is responsible for gradually deflecting upper layer(s) of


soil reinforcement downward (15 maximum from horizontal) to avoid
cutting soil reinforcement and conflicts with paving and subgrade

45

preparation. The Contractors attention is directed especially to


situations where roadway superelevation and/or soil mixing are

Front Face of

anticipated.

Temporary

9:
34:
47 AM

rd960rh

Retaining Wall

TEMPORARY TRAFFIC RAILING

12/30/2011

PLACEMENT DETAIL

LAST
REVISION

01/01/11

REVISIO N

GENERAL NOTES AND DETAILS

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

TEMPORARY MSE RETAINING WALL SYSTEMS

NO.

6030

SHEET
NO.

Bulkhead Cap

SHEET PILE DESIGN CRITERIA AND NOTES

(See Bulkhead Plans


for actual Cap outline)
DESCRIPTION:
This Design Standard includes details for three types of piles with two thicknesses.
Types "B" and "C" piles (corner piles) are of reinforced concrete construction, and Type "A" is of prestressed

Compacted Fill

of the contract documents.

(
M in.
)

1
-0"

concrete construction. The piles shall be manufactured, cured and installed in accordance with the requirements

MATERIALS: (for materials not listed refer to the Specifications)


CONCRETE
Class:

V (Special) for slightly and moderately aggressive environments


V (Special w/ Silica Fume) for extremely aggressive environment

Plastic Filter Fabric


(Continuous)

Sheet pile

Unit weight:

150 pcf

Modulus of Elasticity:

Based on the use of Florida limerock concrete

REINFORCING STEEL
ASTM A615 Grade 60

PRESTRESSING STEEL
ASTM A416 Grade 270 (Low-Relaxation Strand)

Existing Ground
(Mud Line)
CROSS REFERENCES:

DESIGN PARAMETERS:

For Dimensions L and X see Sheet

Type "A"
1
-8"

Pile Data Table in Structures Plans.

Concrete Compressive Strength at release of prestressing:

4000 psi minimum

Uniform compression after prestressing losses:

1000 psi minimum

Pick-up, Storage and Transportation:

0.0 psi tension with 1.5 times pile self weight

Types "B" & "C"


Bottom of Dim. X

Pick-up, Storage and Transportation:

Minimum compressive strength fci = 4000 psi required.

and Filter Fabric


ENVIRONMENT:
C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06040-1of4.
dgn

The pile designs are applicable to all Environments.

SECTION THRU BULKHEAD


PLASTIC FILTER FABRIC:
(Showing Plastic Filter Fabric)

The plastic filter fabric shall extend to the bottom of the "X" dimension.

PILE PICK-UP AND HANDLING:


Type "A"

Grout (Typ.) (See Specifications)

Pick-up of pile may be either a single point pick-up or a two point pick-up as shown below.
Types "B" & "C"

2-6"

Two point pick-up for lifting out of forms & two point support for storage & transportation.
Type "A" (Typ.)

Single point pick-up for installation only.

PILE FIT-UP:

90

The 2-6" Sheet Pile dimension is nominal. This dimension may be shortened by the Manufacturer up to b" to
allow for Sheet Pile fit-up in its final position. Minimum Sheet Pile width is 2-5b". No changes shall be made
to the tongues or grooves.
Type "A"

Type "A"
Type "A"

Type "C"

Starter Pile

Type "B"

Plastic Filter Fabric

DETAIL "A"
(Cap and Anchoring System Not Shown)
(Section Taken Above Dimension X)
NOTE: Detail "A" shows a Part-Plan View of an assumed bulkhead.
See Bulkhead plans for actual Plan View.
1-3"
Pile and
Starter Pile
Single Point

rd960rh

2 Point Pick-up, Tie Down and Support Points

Pick-up

1-3"

T
1
y
C
o pi -3
r
"
n ca
e
l
r
f
o
P
il r
e
s

9:
34:
48 AM

0.21 L

DETAIL "A"

0.58 L

0.21 L

PILE STORAGE AND TRANSPORTATION SUPPORT DETAILS

12/30/2011

(Section Taken Below Dimension X)

LAST
REVISION

01/01/11

REVISIO N

NOTES AND DETAILS

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

PRECAST CONCRETE SHEET PILE WALL

NO.

6040

SHEET
NO.

BAR BENDING DIAGRAMS

4" (Typ.)
11"

(Typ.)
Slope only on the tongue side
10"

S2

Bar S5
Bar S4

45

S1

"

Bars

"
0
1

Bars

BAR A

4b "

1-6

S5

1-10

"
"

S6

11"

S7

1-7 "

T=10 in.

4"

T=12 in.

6"

7"

2-PIECE

6 sp. @ 4"

2-2"

S4

DIMENSION B
B

"

1-9b "

S3
A

Varies

1-11

S2

Pick-up Strand(S)

1
-0

11"

(
Typ.
)

S1

Strands

1
-3"

2 ~ Bars A

DIMENSION A

(Typ.)

Prestressed

(
M in. Lap)

Spaced at 1-0" Maximum

3 "

6 sp. @ 4"

1-PIECE

BAR S

Spacing for
Bars S
NOTES:

TYPICAL PILE

1. Intermediate Prestress Strands not shown in Elevations and Sections.

T(in.)
Y(in.)
11"

10

Z(in.)

3.

12

Bars A are #5 and Bars S are #4.

4. At the Contractors option Bars S may be fabricated as a two piece bar


as shown in the Bar Bending Diagram.
5. The Contractor may use Deformed Welded Wire Reinforcement conforming to

(Typ.)

specification ASTM A497 in lieu of Bars A and Bars S if the wire size and
spacing provide the same area of reinforcing steel per foot as the Bars shown.
10"

2 "
D

(Typ.)

Bars A

(
Strands)

(Typ.)

Bars S2
3" Cover

n sp. @

D
Bars S1
3" Cover

T
See Detail "D"

2
-6"

2 "
n sp. @

"
1
-0

2
-6"

Bar S7
Bar S6

Bars A
n sp. @

S2

See Detail "E"

2
-6"

Bars

S3

(
Strands)

Strand(S)
Bars

11"

Pick-up

2" Cover

T
See Detail "D"

(
Strands)

Strands

2" Cover

(Typ.)

Prestressed

2 ~ Bars A

6. For Dimensions L and X see Sheet Pile Data Table in Structures Plans.
2" Cover

(
Typ.
)

Bars S3
3" Cover
(Typ.)

6 sp. @ 4"

Spaced at 1-0" Maximum

6 sp. @ 4"

3 "

SECTION A-A
Y

STARTER PILE

b" 2
Thickness

(in.)

T=10 in.

0.5

28-0"

0.6

27-0"

0.5

31-0"

0.6

30-0"

9:
34:
49 AM

T=12 in.

D
(in.)
3
5
2
4

TOTAL # OF
STRANDS

"

b"

b"

4"

3"

2"

2 "

SECTION C-C

b"

* STRESS

SECTION
MODULUS (in.)

(psi)

14

500

1150

10

500

1160

16

720

1100

12

720

1160

2 "

MAXIMUM

"

SECTION B-B

2"

rd960rh

STRAND DIA.

2"

Spacing for
Bars S

Wall

Cover

4b "

7"

Cover

2 ~ Bars A

Cover

Bars A

2"

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06040-2of4.
dgn

2. All bar dimensions are out-to-out.

SHEET PILE DIMENSIONS

12/30/2011

* Unit Prestress after losses.

DETAIL "D"

DETAIL "E"

(Typical Tongue)

(Typical Groove)

LAST
REVISION

01/01/11

REVISIO N

TYPE "A" STANDARD SECTION


DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

PRECAST CONCRETE SHEET PILE WALL

NO.

6040

SHEET
NO.

L
See Detail "D"
Slope only on tongue side

11" Slope is to
11"

this point

2-2"
Bars A3

Bars A1

Bars A2

7"
Bars A2

Bars A1

Bars A2
Bars A1

Bars A3

Bars A3

"
-3
1

Bars A3

Bars S3
Bars A4
S2

Bars A3
Bars A4

Bars A4

S1

4"

Bars S1

Bars A4
Bars S2

Bars A4

Pick-up Strand(s)
Bars A4

Bars A4
Bars A4

Bars A4

Bars S4

Bars A4
Bars A4

1
-3
"

Bars A4

3" Cover (Typ.)

3" Cover
(Typ.)

SECTION A-A
T

Bars A4

SECTION B-B

10"

bT

VIEW C-C
4 "

6 sp. @ 4"

Spaced @ 1-0" Maximum

6 sp. @ 4"

3 "

R2

R3

R4

R5

"

1-6b "

2b "

5"

S2

1-1b "

"

1-8

2b "

4b "

"

"

5b "

R7

R8

5b "

4 "

4 "

"

BAR MARK

R1

S1

11b "

S2

30

1-1

"

2"
R3

R4

10"

1-6"

3b "

R5

R6

7"

10"

1-8 "

3b "

6b "

1-5

2"

7"

R7

R8

"

"

6"

5 "

"

6"

4b "

T (in.)

30
S3
S4

11 "

4 "

S1

11b "

8"

S2

1-1

1-6"

8"

11 "

"

8"

1-1

"

1 "
1

1-5

"

4"

1-4"

4"

"

5"

4b "

4b "

5"

5b "
4b "

"

6b "

S3

11b "

"

2b "

6 "

S4

11b "

4"

1-1 "

2 "

7"

8"

4"

S1

1-0"

8b "

1-3 "

5 "

7b "

8"

7b "

5"

"

2b "

8 "

6 "

8b "

5 "

S2

1-2 "

8b "

1-5b "

5 "

6b "

7 "

5b "

S3

1-0"

7"

1-4"

3"

7b "

7"

S4

1-0"

3b "

4"

45

7 "

"

8b "

5 "

S3

11b "

"

1-4"

S4

11b "

3b "

1-0"

3"

S1

1-0"

6"

1-0

"

5 "

S2

1-2"

6"

1-2

"

5 "

S3

1-0"

1-1b "

3 "

6"

S4

1-0"

2b "

10"

4b "

6"

5b "
5b "

"

"

"

7"

7 "

6"
4

"

11

"

"

7b "

5"

3b "

9"

7 "

10 "

3"

S1

1-0b "

6 "

11

"

7"

10b "

3"

S2

1-2

6 "

1-2"

7"

5 "

S3

1-0b "

5"

1-1b "

4"

8"

8"

9"

7"

7b "

S4

1-0b "

2b "

9b "

5b "

8"

5b "

4 "

9 "

"

"

8"
6

"

"

8"

10

"

4"

10

"

4"

Y (in.)
Z (in.)

12

b"
Z

b"
4"

bT

Z
3b "

5"

10

3"

45
2 "

SHEET PILE DIMENSIONS

Bars A1 or A4

"

R2

Bars S

Bars A2

STIRRUP DIMENSIONS (T = 12")

R6

b"

bT
T

60

60
"

8"
5

"

4"

"

DETAIL "D"
NOTES:

R6

4"

R5

R6

(
Typ.
)

4"

(
Typ.
)

1. This drawing includes details for precast concrete corner piles for 10"
R5

R5

and 12" thick sheet pile systems. The details apply equally to both thicknesses.

R6

2. The bar configurations shown in Sections A-A and B-B shall be used for
angles between 15 and 75. For angles not shown, the reinforcing bar

3. All bar dimensions are out-to-out.


R3

R1

R3

R3

R1

dimensions may be interpolated or extrapolated from the stirrup dimensions shown.


R1

rd960rh

R1
11 "

Y
"

2"
Co
ve
r

BAR BENDING DIAGRAMS

S1

2"
r
ve
Co

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06040-3of4.
dgn

(TYPE "B" PILE)

BAR MARK

b"

Bars S

ELEVATION

STIRRUP DIMENSIONS (T = 10")

bT

Spacing for

Varies

4.

Bars A are #8 and Bars S are #4.

5. Values for Stirrup Dimensions are shown for equal to 30, 45 & 60 only.

R2

R2
R8

R7

R8

R4

R4

R4

R2

12/30/2011

R7

"
0
1

9:
34:
50 AM

6. At the Contractors option Bars S may be fabricated as a 2 piece bar with


45

R7

R8

BAR A2

a minimum lap length of 1-6", as shown in Bar Bending Diagrams.


7. If Type "B" pile is used as a Starter Pile show tongue on both sides of pile
from Dim. X down. Show dimensions for Bars S2, S3 & S4 in shop drawings.
8. If tongue must be on the opposite side from that shown all dimensions and Bars A,
S2, S3 and S4 will be the same but opposite hand.
9. For Dimensions L, X and Angle , see Sheet Pile Data Table in Structures Plans.

1 - PIECE

2 - PIECE

BARS S3 & S4
TYPE "B" - VARIABLE ANGLE CORNER PILE

LAST
REVISION

01/01/11

REVISIO N

BARS S1 & S2
DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

PRECAST CONCRETE SHEET PILE WALL

NO.

6040

SHEET
NO.

here if T=12"

See Section C-C

Bars A1

2 ~ Bars A2

10"

Bar A4

(Typ.)

Bars S3

** Bar A4

Bar A5
1
-9"

Bar A5

1
-8"

1
-9"

Bars S1
1
-8"

S2

* Bar A4

* Bar A4

Bars S4

Section C-C

3" Cover

Bars A1

Bars S5

See
2"

(
Typ.
)

2-2"

Bar A6

Pick-up

Bars A2

** Bar A4

Bar A6
T

"

This A4 bar ends


T

For 12" Pile

10

1-4"

For 10" Pile

Strand(s)

For 12" Pile

For 10" Pile

Bars A5

3"

1-8"

(Typ.)

1-9"

Bars A3

Bars S2

Bars A3

Bars A3

7"

2" (Typ.)

3" Cover

Bars S1

END VIEW
4"

Spaced @ 1-0" Maximum

6 sp. @ 4"

3 "

6 sp. @ 4"

Spacing for

SECTION A-A

1-8"

For 10" Pile

1-9"

For 12" Pile

SECTION B-B

Bars S

ELEVATION
* This Bar A4 shall be 1-2" shorter than other A4 bars for T = 12".

(TYPE "C" PILE)

Bars A2

** This Bar A4 (not shown in elevation) is included only if T = 12".

"

BAR BENDING DIAGRAMS

Bar S2

Y
Bar S3
Bar A5

"

R2

STIRRUP DIMENSIONS

R3

b"
T (in.)

Bar S4

BAR MARK

R1

S1

7"

R2

R2

b"

R3

10

Bar A6

8"

"

7 "

"

S4

5b "

6b "

"

S5

"

"

"

12

Bars S2

S1

9"

S2

9"

7"

"

S3

8 "

6 "

"

S4

7b "

5b "

"

S5

"

9"

6"

6"

5"
5"

1-3"

For 10" Pile

1-3"

For 12" Pile

For 12" Pile

3"
b"

For 10" Pile

45
-

(Bars A2 only)

BARS A

Bar S2
Bar S3

Bar A5

Note: All Bar dimensions are out-to-out.

SHEET PILE DIMENSIONS


Bar S4
Bar A4

T (in.)

10

12

Y (in.)
Z (in.)

SECTION C-C (T=10" or 12")

Bar A6

NOTES:
1. All bar dimensions are out-to-out.

Bar S5

Bars

A3
rd960rh

"

"
0

2 "

Bul

"

Varies

1-2"

4"

Bars A2
Bar A6

STIRRUPS S
0" A5

"

3b "A3

Bars A3

Bar A4

4"

7"
6 "

2b " A4

SECTION D-D (T=10")


b"

S2
S3

4b "A2 & A6

** Bar A4

7"

90

1
-3"

1
-3"

Bars A2

"

4"

*Bar A4

Bar A5

R1

Bar S5

A3

2"

2"

Bars

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06040-4of4.
dgn

Bar A4
3

2.

Bars A are #8 and Bars S are #4.

3. This drawing includes information for precast Corner Piles for 10" and 12"
thick Sheet Pile systems. The details apply to both thicknesses but the bar
configurations change slightly according to the thickness values used.
4. If Type "C" pile is used as a Starter Pile show tongue on both sides of

9:
34:
51 AM

pile from Dim. X down. Show dimensions for Bars S2, S3, S4 & S5 in
shop drawings.
5. If tongue must be on opposite side (Groove Side) from that shown,
all dimensions and reinforcement shall follow the corresponding Tongue
or Groove side.

12/30/2011

SECTION D-D (T=12")

6. For Dimensions L and X see Sheet Pile Data Table in Structures Plans.

LAST
REVISION

01/01/11

REVISIO N

TYPE "C" - RIGHT ANGLE CORNER PILE

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

PRECAST CONCRETE SHEET PILE WALL

NO.

6040

SHEET
NO.

b " Open Joint


Dim. A

)
.
n
"Mi
0

0
1
l (
a
c
i
p
"Ty
0

0
g~ 3
n
i
c
a
p
S
t
n
i
o
nJ
e
b"Op
Top of C-I-P

b " Open Joint

sp. (lap with Dowel

Coping)

Slope of C-I-P

* 2" Min. Cover (Typ.)

Retaining Wall Panel) (Typ.)

** 3" Min. Cover (Typ.)

Drainage Ditch when

Coping

Bars 4A (follows
Bars 4U1 @ 1-6" Max.

Bars 4B (follows top of

required (See Wall Control


Bars 4U1

Drawings for details)

" Chamfer

Bars 4D) (Typ.)

Bars 4A

(Typ.)
Varies
(1-3" Max.,

(Typ.) (See

2" Min.)

2
-0"

Dowel Bars 4D

Note 2)

Bars 4B shown as (

Top of Retaining
Dowel Bars 4D

Wall Panel (Typ.)


Clearance
Bottom of

(See Note 2)

6"

Varies

C-I-P Coping

Retaining Wall Panel


Retaining Wall

(See Wall Company

Panels (Typ.)

Drawings for Details)

Smooth or Textured Face of Panel

PRECAST AND C-I-P COPING NOTES:


C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06100-1of2.
dgn

1.

Provide Class II concrete for slightly aggressive environments


or Class IV for moderately or extremely aggressive environments.

C-I-P COPING - PARTIAL ELEVATION VIEW


2.

SECTION A-A
Panel width

C-I-P COPING

Dowel Bars 4D extend 1-0" above the top of retaining

Dim. A

+ 6"

wall panel. Field cut as necessary to maintain 2" minimum

Panel width

cover. See Wall Company Drawings for number and spacing

Dim. B

of Dowel Bars 4D.


3.

+ 1-0" Min.

Payment for Dowel Bars 4D, Buildup Concrete and Coping will
be made under Retaining Wall System (Permanent).

b " Open Joint

Dim. B

* 2" Min. Cover (Typ.)


b " Open Joint

Control Drawings
Bars 4U2

* For Slightly and Moderately

Bars 4A

Aggressive environments

for details)

(Typ.)

" Chamfer (Typ.)


** For Extremely Aggressive
environments.

2
-0"

2" Cover
Min.

1
-3"

Buildup Concrete

required (See Wall

Wall Panel (Typ.)

2" Cover

Varies

Coping

(
1
-0" M ax.
)

Top of Precast

Drainage Ditch when

** 3" Min. Cover (Typ.)

Top of Retaining

)
.
n
"Mi
0

5
g(
n
i
p
tCo
s
a
c
e
lPr
a
c
i
p
"Ty
0

0
1
Top of C-I-P

C-I-P Buildup Concrete


(1-0" Max.)
Provide 3b " x 3b " preservative
treated timber blocking @ 5 Max.
Spacing for gaps > 1"

Bars 4U2 @
1-4" sp. (Typ.)

Varies (1-3" Max.,

Bars 4A

Clearance

rd960rh

Dowel Bars 4D
"

(See Note 2)

Varies

Dowel Bars 4D (Typ.)


Bottom of

2" Min.)

(See Note 1)

Precast Coping

6"

6"

Min.

Min.

" Std.
(
b " Min. ~ 2b " Max.)

Retaining Wall
Retaining Wall Panel

Panels (Typ.)

(See Wall Company

Smooth or Textured Face of Panel


9:
34:
52 AM

Drawings for Details)

SECTION B-B
PRECAST COPING

LAST
REVISION

01/01/12

REVISIO N

12/30/2011

PRECAST COPING - PARTIAL ELEVATION VIEW

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

MSE WALL COPING (PRECAST OR C-I-P)

NO.

6100

SHEET
NO.

REINFORCING STEEL BENDING DIAGRAMS - PRECAST AND C-I-P COPINGS


BILL OF REINFORCING STEEL

MARK

SIZE

LENGTH

LENGTH

* S or M

* E

Dim. B

REINFORCING STEEL NOTES:

* 2" Min. Cover (Typ.)

1. All bar dimensions in the bending diagrams are out to out.

** 3" Min. Cover (Typ.)

Drainage Ditch when

2. All reinforcing steel at the open joints will have a 2" minimum cover.

required (See Wall

3. Bars 4A may be continuous or spliced at the construction joints. Lap splices for Bars 4A will

Control Drawings

Bars 4U2

Bars 4A

be a minimum of 1-8".
A

AS REQD.

AS REQD.

AS REQD.

AS REQD.

2-0"

2-0"

3
4"

4. The Contractor may use Welded Wire Reinforcement when approved by the Engineer. Welded Wire

for details)

(Typ.)

Chamfer (Typ.)

Reinforcement will conform to ASTM A 497.


Recess Varies

Varies

(1-3" Max., 2" Min.)


2
-0"

* S = Slightly Aggressive

Panel width + 4"

Panel width + 3"

U2

Panel width + 8"

Panel width + 6"

U3

Varies

Panel width + 3"

Dowel Bars 4D

Varies

(See Note 2, Sheet 1)

Ground
Line

6"

required to maintain
2" minimum cover

DOWEL BAR 4D

BARS 4A & 4B

BAR 4U1

BAR 4U2

BAR 4U3

6"
Min.

2
-0" M in.

* 1
-8"
Field cut as

** 1
-6"

* 1
-8"

Length as Required

4B

** 1
-6"

Length as Required
2
-0"

4A

Panel width + 4"

E = Extremely Aggressive

Varies

* 8" M in.

U1

** 6" M in.

M = Moderately Aggressive

(Match
Precast
Dimensions)
Retaining Wall Panel

Leveling Pad for

(See Wall Company

MSE Wall Shown

Drawings for Details)

C-I-P COPING USED WITH PRECAST COPING

wall, use this similar C-I-P coping for short portions between precast
coping units. This C-I-P coping may also be used for vertical copings.

Dim. C

* For Slightly and Moderately


Aggressive environments

Top of Coping

Top of Retaining
* 2" Cover (Top & Sides)

Wall End Panel

** For Extremely Aggressive

** 3" Cover (Top & Sides)

3
4"

Retaining Wall

Spacing

Bars 4A (follows Slope


of C-I-P Coping Enclosure)
Bars 4B (Horizontal) (Field
cut as required to maintain

Chamfer (Typ.)

Bars 4B

Begin or End

environments.

Panel width

minimum cover)

Dim. B

Bars 4A (Typ.)

+ 1-0" Min.
Panel width

Bottom of Coping

Drawings for details)

Bars 4B shown
as (

(Typ.)

Bars 4U3

Bars 4U3 @ 1-6"

Edge of Retaining

Max. sp. (Typ.)

Bars 4B (Horizontal)

4" Cover

Leveling Pad for

9:
34:
53 AM

(Bottom)
3" Min. Overlap

412"

rd960rh

6"

Wall End Panel

2
-0" M in.

(See Wall Company

Coping Enclosure

+ 6"

Varies

Retaining Wall End Panel


Edge of C-I-P

1
-6" M ax.

Dim. C
Eq. sp. @

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06100-2of2.
dgn

Note: When precast coping units do not fit the entire length of the retaining

MSE Wall Shown

SECTION C-C

Varies

LAST
REVISION

01/01/12

REVISIO N

12/30/2011

C-I-P COPING ENCLOSURE DETAIL

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

MSE WALL COPING (PRECAST OR C-I-P)

NO.

6100

SHEET
NO.

1" Dowel Load Transfer


Devices (See Typical Sections

Top of

for details)

Junction Slab

Expansion Joint (See

Bars 5C @ 8" sp.


Bars 5B2
4 ~ Bars 5F

b" V-Groove (See

2" Cover

(tie to Bars 4A)

Note 7 & Detail "A")

Sides (Typ.)

(Typ.)

Bars 4A @

"Expansion Joint Detail"

1" Dowel Load

this sheet and Detail "A")

Transfer Devices

4" (Typ.)

(Top of Slab)
Approved metal

(Required only

or fiber cap

when Junction
Slab is skewed)

2
-0" M in.

Junction Slab
3"

Approach Slab

" Preformed Expansion

(See Note 12)

3s
p.
@

6"

Joint Filler
1-0"

Lap Splice

"

Bottom of

Gutter Line

1-0"

Expansion
Bars 4L @ 8" sp.
(Typ.)

EXPANSION JOINT DETAIL


(Junction Slab expansion joints are to coincide
with

Field cut reinforcing as required

" open joints in Traffic Railing)

3"
Spacing Bars 5V2

" Open Joint

to maintain minimum cover (Typ.)

Bars 5V2 (Typ.)

Bars 5S

Coping

Bars 5B1

in Precast Coping

8" Spacing (Typ.) (See Note 1 & 9)

CROSS REFERENCE: For Detail "A", see Sheet 2.

2" Cover @
b " V-Groove Spacing

2" Cover @

30-0" Max. (See Note 7)

Expansion Joints

Begin or End Retaining Wall

" Expansion Joint Spacing ~ 30-0" Min., 90-0" Max. (See Not

" Open Joint in Precast

Coping and C-I-P Traffic

and Precast or C-I-P Coping

Railing to coincide with

PARTIAL PLAN VIEW FOR F-SHAPE TRAFFIC RAILING

" Open Joint

"

Expansion Joint in Junction


Slab.

(Skewed Approach Slab Shown, Perpendicular Approach Slab Similar)


(Precast Coping Shown, C-I-P Coping Similar) (Traffic Railing not Shown for Clarity)

JUNCTION SLAB NOTES:

" Open Jo

1.

Precast Coping and

Top of Precast Coping

Railing

Provide Class II concrete for slightly aggressive environments or Class IV for moderate or extremely

Top of C-I-P

aggressive environments.

Buildup Concrete

Dowel Load Transfer Devices will be ASTM A 36 smooth round bar and hot-dip
galvanized in accordance with Specification Section 962. Install Dowel Load Transfer Devices in accordance
Top of Retaining

with Specification Section 350.


5.

Wall Panel (Typ.)

Construct " Expansion Joints in junction slabs and C-I-P copings plumb and perpendicular or radial to

-3"
2

Gutter Line. Provide at 90-0" maximum intervals as shown. Provide 3"x3" Mortar plugs in open joints at the

(
9" M ax.
)

4.

Varies

and/or junction slab is not permitted.


3.

base of traffic railings to contain runoff.


6.

Provide and install Preformed Expansion Joint Filler in accordance with Specification Section 932.

7.

Construct b" V-Grooves in junction slabs and C-I-P copings plumb and provide at 30-0" maximum intervals as

Mortar Plug
(See Note 5)

3"

Construct the Junction Slab level transversely and expansion joints plumb;

do not construct the junction slab or C-I-P coping perpendicular to the roadway surface. Slip forming of Coping

2" Cover M in.

CONSTRUCTION REQUIREMENTS:

Precast Traffic Railing

Traffic Railing

Traffic

spacing within 6-0" of Open Joints for precast coping with the 42" F-Shape Traffic Railing.
2.

Top of

Coping

For TL-5 crash test rating increase Expansion Joint Spacing to 60-0" minimum and provide Bars 5C at 6" max.

)
.
n
"Mi
0

5
y(
l
n
gO
n
i
p
tCo
s
a
c
e
l Pr
a
c
i
p
y
"T
0

0
1
s*
n
o
i
t
c
e
S
g
n
i
p
g & Co
n
i
l
i
c Ra
i
f
f
a
r
tT
s
a
c
e
m Pr
mu
i
n
"Mi
0

2
1

Precast

APPLICATIONS: This junction slab is only applicable for a TL-4 crash test rating.

Varies

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06110-1of6.
dgn

Open Joints

shown. Space V-Grooves equally between " Expansion Joints and/or Begin or End Junction Slab. V-Gr
locations are to coincide with V-Groove locations in the Traffic Railing.

rd960rh

8.

Shoulder or Roadway Pavement is required on top of the junction slab for its entire length on the traffic

Clearance

side of the Traffic Railing. See Typical Sections on Sheet Nos. 2 and 3 for details.
9.

Varies

Spacing shown is along the Gutter Line.

10.

On MSE Walls provide, Dowel Bars 4D and extend to 7" above the top of retaining wall panel. Field cut as

Bottom of

Dowels 4D (Typ.)

Precast Coping

(See Note 9)

necessary to maintain 2" minimum cover to the top of the buildup concrete. See Wall Company Drawings for
9:
34:
53 AM

number and spacing of Dowel Bars 4D.


11.

Work this Index with the following:

Retaining Wall (MSE Shown,

Index No. 420 - Traffic Railing - (32" F-Shape)

Other Types Similar) (Typ.)

Index No. 425 - Traffic Railing - (42" F-Shape).


12.

PARTIAL ELEVATION VIEW

The following Indexes contain details of the intersection of the retaining wall at approach slabs:

(Precast Coping and Junction Slab Reinforcing not Shown for Clarity)
(Precast Coping Shown, C-I-P Coping Similar)

Index No. 20910 - Approach Slabs (Rigid Pavement Approaches)

LAST
REVISION

01/01/12

REVISIO N

12/30/2011

Index No. 20900 - Approach Slabs (Flexible Pavement Approaches)

* C-I-P End Section must


be = 12-0".

DESCRIPTION:

FDOT DESIGN STANDARDS


FY 2012/2013

INDEX

WALL COPING WITH TRAFFIC RAILING/JUNCTION


SLAB

NO.

6110

SHEET
NO.

1
2"

6-6

3
4"

(C-I-P Junction Slab)

Bars 4N @ 8" sp.

Joint Permitted

expansion joints (Typ.)

for C-I-P

Coping
Bars 5S

1
-0"

(See Note 2)

6"

1
-0"

NOTE: See Index No. 420 and Index No. 425, Detail "A" for details.

2" Cover

6"

(Showing Bars 5V and Bars 5S)


(Precast Coping Shown, C-I-P Coping Similar)

3" Cover

Bars 4L @ 8" sp.

Utility Conduit
permitted
C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06110-2of6.
dgn

Bars 5B2 @ 1-0" sp. (Typ.)


Slope Permitted See Note 7

ESTIMATED QUANTITIES FOR PRECAST COPING

UNIT

Concrete (Precast Coping Only)

Two Layers 30Lb. Roofing Felt

QUANTITY

CY/LF

2
-3"

3
4"

TRANSITION FOR GUARDRAIL ATTACHMENT

ITEM

Top of

(
Precast Coping)

PARTIAL END VIEW OF TRAFFIC RAILING END

3
4"

@ 8" sp.

3
4"

(
Se
e No
t
e1
)

Bars 5V2

6"

Sl
o
p
e Va
r
i
e
s

asphalt or See Note 3)

7"

substituted)

2" Cover (Top)

3"

Pavement (Full depth

3
4"

Shoulder or Roadway

(Bars 5V2 may be

End Stirrup Bar 5V

114"

10
"R

Sections*

Bars 4A @ 4" sp.


Precast Coping

2
"Co
v
e
r

Construction

Transfer Devices at

(Rotated)

812"

1" Dowel Load

(Typ.)

12
-0" M in. Length)

1
-10"

Bars 5S

1
-114"

Bars 5V

8"

6"

Bars 5S (Field Bent)

(Tied to alternate Bars 4A)

2
-8"

Bars 5C @ 8" sp.


Min. Embed. (42" F-Shape)

Coping

(
Precast Traffic Railing

@ 8" sp.

Min. Embed. (32" F-Shape)

114"

Bars 5P

"

1
3" 4 2"

Railing

214"

Traffic

1
-0"

312"

(Tied to Bars 5P)

3" Precast 32" F-S

714"

1" C-I-P F-Sh

Top of Precast Coping

1
2"

5"

312"

5-0"

8"

(42" F-Shape)

2"

(32" F-Shape)

1-5"

Cover

1-2b "

Varies (2" min.)

2" Min. Cover

0.079

Spacing Bars 5B1

514"

Optional widening & extension for Precast Coping (See Note 6)


Retaining Wall (Type Varies)

Concrete (Precast Barrier & Coping)

CY/LF

Dowel Bars 4D (MSE Walls only)

0.165

Concrete (C-I-P Junction Slab)


Reinforcing Steel (Precast Coping & Traffic
Railing)

CY/LF

Spacing

Dowels

0.185

Bars 5S

6"

C-I-P Buildup Concrete

LB/LF

52.67

LB/LF

(MSE Walls only)


Smooth or Textured

b" Min. ~ 2b" Max. Gap

Face of Wall
Spacing

Reinforcing Steel (C-I-P Junction Slab) (Typ.)

6"

3 sp. @ 1-0" = 3-0"

1-3"

Spacing 1"

4 sp. @ 1-0" = 4-0" (5B2)

3"

2 sp. @ 1-0" (5B1)

3"

Bars 5B

12.52

TYPICAL SECTION THRU PRECAST* 32" F-SHAPE


Additional Reinf. @ Expansion Joints

LB

TRAFFIC RAILING AND COPING WITH C-I-P JUNCTION SLAB

21.36

* C-I-P Traffic Railing and Coping Sections using precast dimensions

(The above concrete quantities are based on a max. superelevation of 6.25%

and reinforcement are permitted at End Sections, Drainage Inlets and

and a 32" F-Shape Traffic Railing.

Light Pole Pedestals if slip forming is not used.


NOTES:
1. Match Cross Slope of Travel Lane or Shoulder.
2. The 3" dimension corresponds to a maximum superelevation of 6.
For steeper superelevations increase this dimension to match roadway
superelevation.

b " V-Groove (Typ.)

b " V-Groove (Typ.)

3. For Rigid Pavement (Concrete), Junction Slab may be thickened to match

rd960rh

finish grade.
4. Minimum length of Junction Slab between expansion joints is 30-0".
" Preformed Expan
Joint Filler

" Preformed Expan


Joint Filler

5. At the Contractors option, mechanical couplers may be used to splice


reinforcing. Complete details, including reinforcement lengths are required
in the Shop Drawings. Provide mechanical couplers in accordance with

9:
34:
55 AM

Specification Section 415. Mechanical couplers shall develop 125% of the bar
yield strength.

C-I-P COPING
PRECAST COPING

6. Contractor to maintain stability of precast coping/traffic railing prior to


junction slab completion. In the Shop Drawings, show reinforcement for
optional extension required for stability, shipping and handling. Maintain

12/30/2011

DETAIL "A"
(Showing Locations of b " V-Grooves and

2" minimum concrete cover.

" Preformed Expansion Joint Filler)

7. Angle varies ~ 0 min., 20 max.

REVISION

01/01/12

REVISIO N

F-SHAPE TRAFFIC RAILINGS


LAST

DESCRIPTION:

FDOT DESIGN STANDARDS


FY 2012/2013

INDEX

WALL COPING WITH TRAFFIC RAILING/JUNCTION


SLAB

NO.

6110

SHEET
NO.

6-6b" (32" F-Shape)

REINFORCING STEEL BENDING DIAGRAMS

3-9"
6-9" (42" F-Shape)

b" (32" F-Shape)


(42" F-Shape)

4-8"

4-8"

4-8"

4-8"

4-5"

4-5"

4-5"

2-6"

N/A

N/A

Transfer Devices at

11-6"

AS REQD.

9-6"

S1

N/A

AS REQD.

9-6"

5-10"

5-10"

5-10"

2-0"

2-0"

2-0"

1
2"

Smooth

1" Dowel

11-6" (Precast Traffic Railing)

5B2

Length as Required

134"

Expanded Polystyrene (b" Side) (for C-I-P only)

Precast Coping ~ 4-8" (See Note 7)

8b "

Contractors

2-0"

1
-1b "

10"

412"

412"

1"

5430

g~
n
i
p
tCo
s
a
c
e
Pr
)
5& 6
e
t
o
N
e
Se
"(
9

3
"
2

g ~6
n
i
p
P Co
I
C-

86

5"

5B2 ~ C-I-P Coping

Spacing

Smooth or Texture
4 sp. @ 1-0" = 4-0"

3"

Face of Wall

2 sp. @ 1-0"

3"

Bars 5B2

TYPICAL SECTION THRU C-I-P TRAFFIC RAILING

Construction Joint Permitted


Optional Keyway

WITH C-I-P JUNCTION SLAB AND C-I-P COPING


Buildup for

(PRECAST COPING SIMILAR WITH C-I-P BUILDUP)

stepped MSE
Wall Panels
2"

BARS 5B, 5C, 5F & 5S

5B1 ~ Precast,

45

M in.

1" DOWEL

Spacing Bars

514" (Precast)

3 sp. @ 1-0" = 3-0"

6"

C-I-P Coping ~ Length as Required

6"

512" (C-I-P)

Dowels
3
-1b " (
42" F-Shape)

32" F-Shape), 9-6" (Coping Only)

45
2
-8b " (
32" F-Shape)

8S1

1-3"

Spacing 1"

Precast Coping, ~ 11-6" (with


5S

6"

Spacing

M ax.

9
"

4-8"

-2
"
1
(3

-5
2
"
"
(4
F
)
2
"
F
)

5F

Retaining Wall (Type Varies)

option

Bars 5S

(0" min.,
11" m
Coping

Expanded
Polystyrene (b")
6"

10"

(32" F-Shape)

1-0b"

(42" F-Shape)

6"

ESTIMATED QUANTITIES FOR C-I-P COPING

BUILDUP FOR STEPPED MSE WALL PANELS

STIRRUP BAR 4N

REINFORCING STEEL NOTES:

NOTES:

ITEM

UNIT

QUANTITY

1. All bar dimensions in the bending diagrams are out to out.

2. The 3" dimension corresponds to a maximum superelevatio


6.25%. For steeper superelevations increase this dimension to match

2. All reinforcing steel at expansion and open joints will have a 2" minimum cover.
Concrete (Traffic Railing not Included)

3. Lap splices for Bars 5B & 5S will be a minimum of 2-0".

5. The Contractor may use either full length Bars 4A or lap splice with Bars 5C at alternate Bars 4A

CY/LF

0.264

for C-I-P Copings.

roadway superelevation.
3. For Rigid Pavement (Concrete), Junction Slab may be thickened to
match finish grade.

Reinforcing Steel (Typical) excluding


Bars 5V2 and 5S (Typ.)

LB/LF

30.89

4. Minimum length of Junction Slab between expansion joints is 30-0".


5. See Index No. 420 & 425 for additional Traffic Railing Details.

6. Dimension shown is for lap splice option. For mechanical coupler option, this dimension is 1-4b"

6. Contractor to maintain stability of precast coping prior to junction

(32" F-Shape) or 1-7" (42" F-Shape).


7. Dimension shown is for lap splice option. For mechanical coupler option, this dimension is 4-8".

Additional Reinf. @ Expansion Joint

LB/LF

21.36

slab completion. In the Shop Drawings, show reinforcement for


optional extension required for stability, shipping and handling.

8. The Contractor may use Welded Wire Reinforcement when approved by the Engineer. Welded
Wire Reinforcement will conform to ASTM A 497.

AND C-I-P COPING

1. Match Cross Slope of Travel Lane or Shoulder.

STIRRUP BAR 5V2

4. For Precast Copings only, lap splice Bars 4A with Bars 5C. Lap splices will be a minimum of 2-0".

9:
34:
56 AM

3b "

Bars 5B2 @ 1-0" sp. (Typ.)

Optional widening & extension for Precast Coping (See Note 6)


5C

1
-10"

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06110-3of6.
dgn

2" Cover
See Note 7

Two layers 30Lb. Roofing Felt

9-6" (Precast Coping only),


5B1

Top of
Coping

Bars 4L @ 8" sp.

STIRRUP BAR 5P

BAR 4A

rd960rh

134"

3" Cover

Bar

(The above concrete quantities are based on a max. superelevation


of 6.25%, beneath a 32" F-Shape Traffic Railing on an MSE Wall).

Maintain 2" minimum concrete cover.


7. Angle varies ~ 0 min., 20 max.

F-SHAPE TRAFFIC RAILINGS


LAST
REVISION

01/01/12

REVISIO N

12/30/2011

114"

10
"R

5b "

V2

Bars 5S

1
-0"

5-7"

Sl
o
p
e Va
r
i
e
s
(
Se
e No
t
e1
)

Bars 5V2
@ 8" sp.

6"

5-7"

2" Cover (Top)

Construction
Joint Reqd.

5-7"

Bars 4A @ 4" sp.

1
-0"

3
-3" (
42" F-Shape)

2
-5" (
32" F-Shape)

expansion joints (Typ.)

30
-0" M in. Length)

N/A

(
C-I-P Traffic Railing

4-8"

3
-6" (
42" F-Shape)

or 8S1 (Typ.)
3
"Co
v
e
r

(
C-I-P or Precast Coping)

1" Dowel Load

2
-3"

AS REQD.

2" m in.
)

AS REQD.

114"

AS REQD.

"

(11

B2

Bars 5S

for Precast Coping

(42" F-Shape)

3b " 9"

3"

(32" F-Shape)

8"

9-6"

8b "

N/A

1
1
2" 3 4"

11-6"

Bars 5P
@ 8" sp.

3" 4

Optional Bar 5C @ 8" sp.

1-

B1

(42" F-Shape)

8"

9"

asphalt or See Note 3)


(32" F-Shape)

3
4"

"

5-7"

6"

5-7"

6"

Spacing Bars 8S1 (42" F-Shape)

Pavement (Full depth


2
-8" (
42" F-Shape)

8-0"

BARS 4L

1
-10" (
32" F-Shape)

Precast

7"

C-I-P

Spacing Bars 5S (32" F-Shape)

2
-8" (
32" F-Shape)

Shoulder or Roadway

6
A

2"

COPING

PRECAST
COPING &
32" F-SHAPE

SIZE

3"

MARK

1
-0"

3b "

1-

(C-I-P Junction Slab)

3
4"

LENGTH

1034"

5"

Varies

8"

5-0"

Cover

BILL OF REINFORCING STEEL

DESCRIPTION:

FDOT DESIGN STANDARDS


FY 2012/2013

INDEX

WALL COPING WITH TRAFFIC RAILING/JUNCTION


SLAB

NO.

6110

SHEET
NO.

4 ~ Bars 5F

3s
p.
@

(Top of Slab)

b" V-Groove

Bars 5C @ 8" sp.

3"

(Required only

Bars 5B2

6"

2" Cover

(Tie to Bars 4A)

4L Bars @

(See Detail "A"

Sides (Typ.)

(Typ.)

8" sp. (Typ.)

& Note 7, Sheet 1)

Expansion Joint (See Expansion

1" Dowel Load

Joint Detail & Detail "A")

Transfer Devices

when Junction
Slab is skewed)

Field cut reinforcement


as required to maintain
minimum concrete

Approach Slab
(See Note 12

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06110-4of6.
dgn

Sheet 1)

Begin or End

Skew Bars 7P1 &

Bars 4L @ 8" (Typ.)

Approach Slab

4V1 as required

Bars 4A @ 4" (Typ.)

" Open Jt.

5-0" End Post

Bars 7P1 & 4V1 (Typ.)


Gutter Line

Bars 5B1

Coping Line

Bars 7P1 &


4V1 (Typ.)

Varies

2-6" (Typ.)

5-0" Interior Post (Typ.)

2-6" (Typ.)

(2-6" Min., 5-0" Max.)

Varies ~ 5-0" (Typ.)

5-0" End Post

5-0" End Post

(2-6" Min., 5-0" Max.)

@ Expansion Joint

@ Expansion Joint

2" Cover @

Open Joints

b" V-Groove Spacing ~ 30-0" Max. (See Note 7, Sheet 1)

" Open Joint in Precast

Coping and C-I-P Traffic


Railing to coincide with

" Expansion Joint Spacing ~ 30-0" Min., 90-0" Max. (See Note 5, Shee

"

Expansion Joint in Junction


Slab.

PLAN VIEW
(Skewed Approach Slab shown, Perpendicular Approach Slab similar)
(Precast Coping shown, C-I-P Coping similar)

CROSS REFERENCES:
1. For Detail "A" see Sheet 2.

(Traffic Railing reinforcement not shown, except for Bars 7P1 & 4V1)

2. For "Expansion Joint Detail" see Sheet 1.


3. For "Junction Slab Notes" see Sheet 1.

Bars 5B2

Bars 5C @ 8" sp.

Bars 5C @ 8" sp.

(Tie to Bars 4A) (Typ.)

(Tie to Bars 4A) (Typ.)

Bars 5B2

Guardrail

Gutter Line

Gutter Line

4b " Taper
(Typ.)

Face of Curb

Bars 4L (Typ.)
rd960rh

Lap Splice

2
-0" M in.

cover (Typ.)

Bars 4A (Typ.)

Begin or End
Retaining Wall
Bars 7P1 & 4V1 (Typ.)

Coping and
3-0" Taper
(Inside Face)

Varies (12-6" Min.)

3-0" Taper

Bars 4P5 (Typ.)


Coping Line

2-6" (Typ.)

Bars 7P1 & 4V1 (Typ.)


5-0" Interior Post (Typ.)

Bars 4R3 (Typ.)


2-6" (Typ.)

Coping Line

(Inside Face)

PARTIAL PLAN VIEW OF GUARDRAIL TRANSITION AT BEGIN OR END RETAINING WALL

PARTIAL PLAN VIEW OF COPING WITH CURB

(Precast Coping shown, C-I-P Coping similar)

(Precast Coping shown, C-I-P Coping similar)

(Traffic Railing reinforcement not shown, except for Bars 7P1 & 4V1)

(Traffic Railing reinforcement not shown, except for Bars 4P5, 4R3, 7P1 & 4V1)

12/30/2011

9:
34:
56 AM

Bars 4L

Bars 5B1

Bars 4A

Traffic Railing

REVISION

01/01/12

REVISIO N

CORRAL SHAPE TRAFFIC RAILINGS


LAST

DESCRIPTION:

FDOT DESIGN STANDARDS


FY 2012/2013

INDEX

WALL COPING WITH TRAFFIC RAILING/JUNCTION


SLAB

NO.

6110

SHEET
NO.

Interior Post (C
4 "
11 "

5 "

8"

"
3

b"
1

.
p
5s

.
p
5s

3 "

Guardrail Thrie Beam

6 4"

Joint permitted in rail)

A)
s4
r
e Ba
t
a
n
r
e
t
l
oa
et
i
T
(
"
d@ 8
e
c
a
p
V1 s
P1 & 4
s7
r
Ba

"
5

A
C

clear precast opening

Top of C-I-P
Traffic Railing

"
@ 8

Bars 4S3

Shift Bars 4A & 4L to

W-Beam similar

)
b
r
Cu
P5 (
s4
r
g Ba
n
i
c
a
Sp

.
p
2s

"
6

.
p
2s
"
@ 8

attachment shown,

"
5

"
@ 4

"
@ 4

n
o
i
t
i
s
n
a
r
lT
i
a
r
d
r
a
Gu
g
n
i
c
a
p
S
t
l
Bo
u
r
h
T

V1
P1 & 4
s7
r
g Ba
n
i
c
a
Sp

b" V-Groove

Curb (Precast

)
.
p
y
T
P1 (
s7
r
Ba

permitted for

or C-I-P)

)
.
p
y
T
V1 (
s4
r
Ba

C-I-P Curb

Bars 4P5 (Typ.)

Bars 4R3

C-I-P
Transition

-3"
2

Bars 4A (Typ.)

Begin or End
Retaining Wall

s
e
i
r
Va

Bars 4L (Typ.)
)
.
n
"Mi
6

2
s(
e
i
r
Va

D
r
e
p
a
"T
0

Coping, and

)
e
c
e Fa
d
i
s
n
I
(

Traffic Railing

"
4

4"

r
e
p
a
"T
0

3
)
.
x
"Ma
6

2
)
e
c
e Fa
d
i
s
n
I
(
)
L
4
s
r
a
B
(
"
8
.@
p
4s
A)& 1
s4
r
Ba
"(
.@ 4
p
8s
2

4"

t
s
r Po
o
i
r
e
t
n
I
)
L
s4
r
Ba
"(
.@ 8
p
s
4
1
&
)
A
4
s
r
a
B
"(
.@ 4
p
8s
2

4"

g
n
i
p
tCo
s
a
c
e
lPr
a
c
i
p
y
"T
0

0
1
b
r
h Cu
t
wi

.
p
"s
L@ 8
s4
r
.& Ba
p
"s
A@ 4
s4
r
Ba
g
n
i
p
n Co
o
i
t
i
s
n
a
r
nT
i
g
"Be
0

0
1

4"

"
6

"
6

)
.
p
y
T
"(
0

"
6

,
.
n
"Mi
0

0
(

" Open Joint

in Precast Coping
and Precast Curb

g
n
i
p
n Co
o
i
t
i
s
n
a
r
dT
)En
.
n
"Mi
6

8
s(
e
i
r
Va
C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06110-5of6.
dgn

PARTIAL ELEVATION VIEW OF OUTSIDE FACE OF COPING


(End Transition and Typical Precast Coping with Curb shown, C-I-P Coping similar)

Interior Post (C
Joint permitted in rail)

Expansion Joi

6 "

Begin/End Approch Slab

" Open Joint in

V1
P1 & 4
s7
r
g Ba
n
i
c
a
Sp
o
t
s
r
a
b
e
t
a
n
r
e
t
l
ea
i
T
(
)
L
r4
Ao
s4
r
Ba

b"
4
V1
P1 & 4
s7
r
Ba

Coping & Traffic Railing

"
.@ 8
p
6s

.
p
5s

.
p
5s

"
@ 4

"
@ 4

Top of C-I-P
Traffic Railing

A
)
.
p
y
T
P1 (
s7
r
Ba
)
.
p
y
T
V1 (
s4
r
Ba

Post (Precast or C-I-P)

Top of Precast Coping


Bars 4S3 (Typ.)
Bars 4S3 (Typ.)
Post (Precast or C-I-P) (Typ.)

Bars 4L (Typ.)
Bars 4A (Typ.)

t
s
d Po
"En
0

t
s
d Po
"En
0

)
.
p
y
T
"(
0

s~ 5
e
i
r
Va
)
t
n
i
o
.J
p
l@ Ex
a
c
i
p
y
T
(
)
.
x
a
M
"
0

5
,
.
n
"Mi
6

2
(
4"
)
.
p
y
A
"T
6

7
s(
e
i
r
g Va
n
i
n
e
p
tO
s
d Po
En
)
.
x
"Ma
6

,7
.
n
"Mi
0

5
(
)
.
n
"Mi
6

7
t(
n
i
o
nJ
o
i
s
n
a
p
lEx
a
c
i
p
y

" Open Joint


"T
0

0
1
b
r
u
C
t
u
o
h
t
g wi
n
i
p
tCo
in Precast Coping
s
a
c
e
Pr
"
-0

0
,9
.
n
i
"M
0

0
3
~
g
n
i
c
a
p
s
t
n
i
o
nJ
o
i
s
n
a
p
x
"E

9:
34:
57 AM

rd960rh

"
6

)
t
n
i
o
.J
p
l@ Ex
a
c
i
p
y
T
(

)
.
p
y
T
"(
0

s~ 5
e
i
r
Va
)
.
x
"Ma
0

,5
.
n
"Mi
6

2
(

"
6

4"

)
L
s4
r
Ba
"(
.@ 8
p
4s
A)& 1
s4
r
Ba
"(
.@ 4
p
8s
2

t
s
r Po
o
i
r
e
t
n
I
4"

)
L
s4
r
Ba
"(
.@ 8
p
4s
A)& 1
s4
r
Ba
"(
.@ 4
p
8s
2

)
.
n
"Mi
6

7
t(
n
i
o
nJ
o
i
s
n
a
p
lEx
a
c
i
p
y
"T
0

0
1
b
r
u
C
t
u
o
h
t
g wi
n
i
p
tCo
s
a
c
e
Pr
"
-0

0
,9
.
n
i
"M
-0

0
g ~3
in
c
a
p
ts
n
i
o
nJ
o
i
s
n
a
p
x
"E

"
6

"
6

)
.
p
y
T
"(
0

g
n
i
p
tCo
s
a
c
e
lPr
a
c
i
p
y
"T
0

0
1
b
r
tCu
u
o
h
t
wi

" Open Joint

in Precast Coping
& Precast Curb

NOTE: Wall Panels not shown for clarity.

CROSS REFERENCES:
1. For Sections A-A, B-B, C-C & D-D, see

PARTIAL ELEVATION VIEW OF OUTSIDE FACE OF COPING

12/30/2011

(Precast Coping at Expansion Joint and Typical Precast Coping without Curb shown, C-I-P Coping similar)

Sheet 6.
2. For Junction Slab Notes, see Sheet 1.

REVISION

01/01/12

REVISIO N

CORRAL SHAPE TRAFFIC RAILINGS


LAST

DESCRIPTION:

FDOT DESIGN STANDARDS


FY 2012/2013

INDEX

WALL COPING WITH TRAFFIC RAILING/JUNCTION


SLAB

NO.

6110

SHEET
NO.

1-6b"

1-6b"

Coping

Gutter Line

1-6b"
Coping

Gutter Line

Coping

Gutter Line

Bars 4S3
Const.

(See Note 4)

Joint
1-2"

permitted

(Corral Shape)
4 "

Bars 7P1
(See Note 4)

1b "

1b "

Curb

Bars 4S3

Sealant Detail"

Joint
1-2"

Bars 4P5 (See Note 4)

See "Curb Joint

Const.

(See Note 4)

(
Rail)

C.
I.
P. Only

Traffic Railing -

(Corral Shape)

C.
I.
P. Only

1b "

Index No. 424

Traffic Railing -

(
Post & Rail)

(See Note 4)

(
Rail)

Bars 7P1

Index No. 424

(
Post)

4 "

Precast

(Corral Shape)

or C.
I.
P.

Traffic Railing -

C.
I.
P. Only

Index No. 424

1-2"

required

6" Precast

3b "

or C.I.P. Curb

Bars 4A
6"

Bars 4A

Bars 4A
Embed.

6"

6"

Embed.

Embed.

Bars 5C
Bars 4V1

Bars 5B2

(See Note 4)

Bars 5B2

Bars 5B1 (Typ.)

Bars 4L

Bars 5C
Bars 5B2

Bars 4V1

Bars 4R3
(See Note 4)

(See Note 4)

Bars 4L

Bars 4L

See Sheet 2

Const. Joint permitted

Bars 5B2 (Typ.)

for Junction Slab and


Bars 5B1 (Typ.)

See Sheet 3

Precast Coping Details

for Junction Slab and

See Sheet 2 or 3

C.I.P. Coping Details

for Junction Slab


Trim Bars 4P5 as

and Coping Details

required to clear
Const. Joint

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06110-6of6.
dgn

1-6b" Min.
1-6b" Min.

(See Note 3)

SECTION A-A

SECTION A-A

(See Note 3)

(TYPICAL SECTION C.I.P. COPING WITHOUT CURB)

(TYPICAL SECTION PRECAST COPING WITHOUT CURB)

SECTION B-B

1-6b"
1-6b"

(TYPICAL SECTION WITH CURB)

Coping

Gutter Line
Coping

Gutter Line

(Precast Coping Shown, C.I.P. Coping Similar)


Index No. 424
Traffic Railing -

Index No. 424


Traffic Railing -

(Corral Shape)

"

4 "

1b "

1b "

Bars 7P1
(See Note 4)

C.
I.
P. Only

(See Note 4)

C.
I.
P. Only

4b "
Bars 7P1

(
Transition)

(Corral Shape)

(
Transition)

Top of Curb

Low Modulus
Silicone Sealant
(Type A)

JOINT NOTE:

" (T

Joint sealant required at


4b" Taper

Const.

4b" Taper

Joint
11"

1-2"

Const.

all expansion joints and

Joint

between precast and

required

C.I.P. curb openings.

required
" Preformed Expansion
Bars 4A

Joint Filler (See Detail "A"

Bars 4A

Sheet 2)

6"
Embed.

1" Foam

Bars 5C

Bars 5C
Bars 4V1

Bars 5B2

(See Note 4)

Backer Rod

Bars 4V1

Bars 5B2

2"

(See Note 4)

Bars 4L

Min.

Bars 4L

Bars 5B1 (Typ.)

rd960rh

Bars 5B1 (Typ.)


See Sheet 2 or 3

See Sheet 2 or 3

for Junction Slab

for Junction Slab

and Coping Details

and Coping Details

CURB JOINT SEALANT DETAIL

NOTES:
9:
34:
58 AM

1. See Sheets 2 & 3 for Junction Slab and additional Coping details.
2. Slip Forming of C.I.P. Traffic Railiing is not permitted.

1-6b" Min.

3. Actual width varies depending on type of Retaining Wall used.

1-6b" Min.
(See Note 3)

4. See Index No. 424 for Traffic Railing details and Bars 7P1, 4P5,

12/30/2011

(See Note 3)

4R3, 4S3 & 4V1. Bars 5R2 and 5U are not required in Retaining

SECTION C-C

END VIEW D-D

(TYPICAL SECTION TRANSITION COPING)

(TYPICAL SECTION TRANSITION COPING)

(Precast Coping shown, C.I.P. Coping similar)

(Precast Coping shown, C.I.P. Coping similar)

Wall Coping.

REVISION

01/01/12

REVISIO N

CORRAL SHAPE TRAFFIC RAILINGS


LAST

DESCRIPTION:

FDOT DESIGN STANDARDS


FY 2012/2013

INDEX

WALL COPING WITH TRAFFIC RAILING/JUNCTION


SLAB

NO.

6110

SHEET
NO.

b " V-Groove (See

Bars 5B2

1" Dowel Load Transfer


Devices (See Typical Sections

Top of Raised

for details)

Sidewalk

Note 6 & Detail "B")

2" Cover
Bars 4C @ 6" sp. (tie Bars

Sides (Typ.)

1" Dowel Load

Expansion Joint (See

Transfer Devices

"Expansion Joint Detail "


this sheet and Detail "B")

4C to Bars 5A) (Typ.)

4 ~ Bars 5F
(Top of Slab)
Approved metal

(Required only

or fiber cap

when Raised
Sidewalk is

3"

Approach Slab

3s
p.
@

(See Note 10)

6"

Lap Splice

2
-0" M in.

skewed)

Edge of
Precast Coping
Gutter Line

Bar 5T

"

Bottom of
Raised Sidewalk

" Preformed Expansion


Bars 5L @ 6" sp.
Joint Filler
1-0"

(tied to alternating
Bars 5T and 5X)

1-0"
Field cut reinforcing

Expansion

& Precast or C-I-P Coping


Spacing Bars

EXPANSION JOINT DETAIL

1-0" sp. (Typ.)

minimum cover (Typ.)

2b "

Bars 5A @ 6" sp.


(tied to Bars 5U1) (Typ.)

6" Spacing (Typ.) (See Note 7)

b " V-Groove Spacing

2" Cover @

2" Cover @

Open Joints

Expansion Joints

30-0" Max. (See Note 6)


" Expansion Joint Spacing ~ 30-0" Min., 90-0" Max. (See Not

" Open J

" Open Jo

PARTIAL PLAN VIEW FOR VERTICAL SHAPE TRAFFIC RAILING

Precast Coping and

(Skewed Approach Slab Shown, Perpendicular Approach Slab Similar)

1.

to coincide with
Expansion Joint in

APPLICATIONS: This raised sidewalk is only applicable for a TL-4 crash test rating.
For TL-5 crash test rating increase Expansion Joint spacing to 60-0" minimum and increase

Bars 4C to Bars 5C or provide Bars 4C @ 4" spacing with the 42" Vertical Shape Traffic
Railing.
2.

C-I-P Traffic Railing

(Precast Coping Shown, C-I-P Coping Similar) (Traffic Railing not Shown for Clarity)

RAISED SIDEWALK NOTES:

" Open Joint

in Precast Coping
Top of C-I-P

CONSTRUCTION REQUIREMENTS: Construct the raised sidewalk level transversely and

Raised Sidewalk.

g
n
i
p
tCo
s
a
c
e
"Pr
0

0
1
n*
o
i
t
c
g Se
n
i
p
d Co
n
ga
n
i
l
i
c Ra
i
f
f
a
r
tT
s
a
c
e
.Pr
n
"Mi
0

2
1

Traffic Railing

Top of Precast Coping

expansion joints plumb; do not construct the raised sidewalk or C-I-P coping perpendicular

Top of Retaining

6.

Wall Panel (Typ.)

Provide and install Preformed Expansion Joint Filler in accordance with Specification

7.

-3"
2

Section 932.
Construct b" V-Grooves in raised sidewalk and C-I-P coping plumb and provide at

30-0" maximum intervals as shown. Space V-Grooves equally between " Expan
Joints and/or Begin or End Raised Sidewalk. V-Groove locations are to coincide with

2" Cover M in.

Construct " Expansion Joints in raised sidewalk and C-I-P copings plumb and perpendic

or radial to the Gutter Line. Provide at 90-0" maximum intervals as shown.

Railing

C-I-P Buildup Concrete

Coping

Top of recessed

Transfer Devices in accordance with Specification Section 350.


5.

Varies

Dowel Load Transfer Devices will be ASTM A 36 smooth round bar


and hot-dip galvanized in accordance with Specification Section 962. Install Dowel Load

(
1
-0" M ax.
)

4.

C-I-P Traffic

Provide Class II concrete for slightly aggressive environments or Class IV for moderately
or extremely aggressive environments.

Precast

to the roadway surface. Slip forming of coping and/or raised sidewalk is not permitted.
3.

V-Groove locations in the Traffic Railing.


8.

Spacing shown is along the Gutter Line.

9.

For MSE Walls, provide Dowel Bars 4D and extend 8" above the top of retaining wall panel.

Clearance
Varies

Field cut as necessary to maintain 2" minimum cover to the top of the buildup concrete.
rd960rh

(Typ.)

Bars 5B1

5T and 5X @

in Precast Coping

Varies

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06120-1of3.
dgn

" open joints in Traffic Railing)

Bars 5S

5T and 5X

(Raised Sidewalk expansion joints are to coincide


with

as required to maintain

Begin or End Retaining Wall

Coping

Alternating Bars

" Open Joint

See Wall Company Drawings for number and spacing of Dowel Bars 4D.
10. Finish Sidewalks in accordance with Specification Section 522.

Bottom of

Dowels 4D (Typ.)

Precast Coping

(See Note 9)

11. Work this Index with the following:


Index No. 422 - Traffic Railing - (42" Vertical Shape)

9:
34:
59 AM

Index No. 423 - Traffic Railing - (32" Vertical Shape)


12. The following Indexes contain details of the intersection of the retaining wall at approach
slabs:
Index No. 20900 - Approach Slabs (Flexible Pavement Approaches)

PARTIAL ELEVATION VIEW

Retaining Wall (MSE Wall


shown, other types similar)

(Precast Coping & Raised Sidewalk Reinforcing not Shown for Clarity)
CROSS REFERENCE: For Detail "B", see Sheet 2.

(Precast Coping Shown, C-I-P Coping Similar)

* C-I-P End Section


must be = 12-0".

LAST
REVISION

01/01/12

REVISIO N

12/30/2011

Index No. 20910 - Approach Slabs (Rigid Pavement Approaches)

DESCRIPTION:

FDOT DESIGN STANDARDS


FY 2012/2013

INDEX

WALL COPING WITH TRAFFIC RAILING/RAISED


SIDEWALK

NO.

6120

SHEET
NO.

1-3"
11"

42" Vertical Shape

7-9"

32" Vertical Shape


5-11" (C-I-P Raised Sidewalk) (See Note 2)

Top of Precast Coping

1-10"

(Shown dashed)
(Precast Coping)

C-I-P Traffic

4" Taper

Railing
Transition Bars 5X

9"

1-1"

32" Vertical Shape

7"

1-3"

42" Vertical Shape


Bullet Railing (Not required for 42"

Coping

(Alternate with Bars


5T) (See Note 3)

(42" Vertical Shape similar)


Transition

Precast Coping

PARTIAL END VIEW OF TRAFFIC RAILING END

Top of Travel

TRANSITION FOR GUARDRAIL ATTACHMENT

Lane or Shoulder

(Showing Bars 5S, Bars 5T and Bars 5X)

Top of

(Precast Coping Shown, C-I-P Coping Similar)

Precast Coping

Coping

(
6" M ax.
)(
See Note 2)

Curb H eight Varies

Bars 5T

1" Dowel Load

Top of Precast Coping

Transfer Devices
Bars 5T @ 1-0" sp.

at Expansion Joints

(Alternate with Bars

Bars 5A @ 6" sp.

5X) (See Note 3)

(lap with Bars 5C)

Bars 4C @ 6" sp.


(lap with Bars 5A)

5"

Bars 5S
(See Note 3)

Ft
/
2 Ft
0
:.
e
p
o
Sl

2"

Top of

See Note 4

3
-6" ~ 42" Vertical Shape

Bars 5X @ 1-0" sp.

(32" Vertical Shape shown)

Coping

(
C-I-P or Precast Traffic Railing)

Gutter Line
C-I-P Traffic Railing

2
-8" ~ 32" Vertical Shape

6" M in.

Bars 5S

Em bed.

Vertical Shape Pedestrian Railing)

UNIT

QUANTITY

CY/LF

0.091

Bars 5B2 @

Expansion Joint Filler

1-0" sp. (Typ.)

Bars 5L @ 1-0" sp.

2
-3" Precast Coping

ITEM

b " Preformed

(Typ.)

6"

ESTIMATED QUANTITIES FOR PRECAST COPING

2" Min. Cover

6"

6"

M in.

Bars 5B1
3" Cover

Two Layers 30Lb. Roofing Felt


Varies

Optional extension for Precast Coping

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06120-2of3.
dgn

1
-1b "

NOTE: See Index No. 422 and Index No. 423, Railing End Detail for details.

(2" min.)
Dowel Bars 4D
Concrete (Precast Coping)

(MSE Walls only)


Spacing

Concrete (C-I-P Raised Sidewalk)

CY/LF

5b"

C.I.P Buildup Concrete

5 sp. @ 1-0" = 5-0"

Spacing

(MSE Walls only)


Bars 5B1

1" Dowels

0.232

Retaining Wall
Spacing

Reinforcing Steel (Precast Coping) excluding


Bars 5T, 5X and 5S (Typ.)

LB

22.00

LB/LF

11.92

LB

32.04

5b"

5 sp. @ 1-0" = 5-0" (5B2)

6"

312"

2 sp. @ 8"

(Type Varies)

= 1-4" (5B1)

Bars 5B

1
4"

5
Reinforcing Steel (C-I-P Raised Sidewalk) (Typ.)

Additional Reinf. @ Expansion Joints

Smooth or Textured
Face of Wall

The above concrete quantities are based on a Type D

TYPICAL SECTION THRU PRECAST COPING WITH C-I-P RAISED SIDEWALK

Concrete Curb (See Note 2).

AND RETAINING WALL AT EXPANSION JOINTS

b " V-Groove (Typ.)

NOTES:

b" V-Groove (Typ.)

1. Actual width varies depending on type of Retaining Wall used.


rd960rh

2. Match roadway curb shape (Type) and height. See Roadway Plans and Index No. 300. 5-11" dimension is based
on a 32" Vertical Shape Traffic Railing with a Type D curb adjacent to a 6-0" wide sidewalk. Adjust this
" Preformed Expans

" Preformed Expans

Joint Filler

Joint Filler

dimension as required for other curb types or transitions at Begin or End Retaining Wall.
3. See Index No. 422 and Index No. 423 for Bars 5S, 5T & 5X and Bullet Railing details. Adjust vertical dimension

9:
35:
00 AM

of Bars 5T and 5X, see Reinforcing Steel Note 5.


4. Trim end of Bars 5T and 5X to clear construction joint for 42" Vertical Shape Traffic Railing.
5. At the Contractors option, mechanical couplers may be used to splice reinforcing. Complete details, including
reinforcement lengths are required in the Shop Drawings. Mechanical couplers shall develop 125% of the bar

PRECAST COPING

C-I-P COPING

12/30/2011

DETAIL "B"

LAST
REVISION

01/01/12

REVISIO N

(Showing Locations of b " V-Grooves and

yield strength.
6. Contractor to maintain stability of precast coping prior to junction slab completion.

" Preformed Expansion Joint Filler)

DESCRIPTION:

FDOT DESIGN STANDARDS


FY 2012/2013

INDEX

WALL COPING WITH TRAFFIC RAILING/RAISED


SIDEWALK

NO.

6120

SHEET
NO.

REINFORCING STEEL BENDING DIAGRAMS - RAISED SIDEWALK

7-9"

BILL OF REINFORCING STEEL


LENGTH
5B1

Bullet Railing

Precast Traffic Railing/Coping ~ 11-6"


5B2

Gutter Line

Length as Required

Bars 5X @ 1-0" sp.

C-I-P Traffic Railing

9-6"/11-6"

B2

AS REQD.

5-5"

5F

5-0"

AS REQD.

5-0"

N/A

BARS 5B1, 5B2, 5C & 5F

5-0"

2-0"
L

4-5"

4-5"

Smooth
Steel Bar

2-0"

2-0"

Top of
C-I-P

1" Dowel

Coping

1
-1b "

1" DOWEL

Precast Coping ~ 3-9"


(See Note 6)

5T) (See Note 2)

(42" Vertical Shape similar)

(See Note 7)

N/A

(Alternate with Bars

(32" Vertical Shape shown)

Precast Coping ~ 5-5"

Coping

Top of C-I-P Coping


(Const. Joint Required)

Bars 5T @ 1-0" sp.


(Alternate with Bars
5X) (See Note 2)

Bars 5A @ 6" sp.


Top of Travel

5"

Lane or Shoulder

Bars 5S

Bars 5B2 @ 1-0" sp. (Typ.)

2"

(See Note 2)

Ft
/
2 Ft
0
:.
e
p
o
Sl

Top of
Coping

2" Cover

3-9"

(Top & Sides)

6"

5C

(
6" M ax.
)(
See Note 1)

B1

8-4"

Curb H eight Varies

4-10"

6"

(
M in.
)

3" Cover

C-I-P Coping ~ 7-3"

b " Preformed
8"

Expanded Polystyrene (b" Side)

Joint Filler

5b "

Spacing

BAR 5A

BAR 5L

Two Layers 30Lb. Roofing Felt

Expansion Joints (Typ.)

Expansion

90

1
-1"

5 sp. @ 1-0" = 5-0"

Spacing

1" Dowels

Bars 5B2
Retaining Wall

REINFORCING STEEL NOTES:

Varies

(Type Varies)
5b "

1. All bar dimensions in the bending diagrams are out to out.

Spacing

2. All reinforcing steel at expansion joints will have a 2" minimum cover.

Bars 5B2

312"

7 sp. @ 1-0" = 7-0"


6"

3. Lap splices for Bars 5B will be a minimum of 2-2".


4. Lap splice Bars 5A with Bars 5C. Lap splices will be a minimum of 2-2".

(1-1" Max., 2" M

Smooth or Textured
Face of Wall

TYPICAL SECTION THRU C-I-P COPING AND RAISED SIDEWALK

5. See Index No. 422 and Index No. 423 for Bars 5S, 5T and 5X. Adjust vertical

AND RETAINING WALL AT EXPANSION JOINTS

dimensions of Stirrup Bars 5T and 5X to 3-0" for 32" Vertical Shape or 3-10"

Construction Joint Permitted

for 42" Vertical Shape.

Optional Keyway

6. Dimension shown is for lap splice option. For mechanical coupler option, this dimension
is 1-8".

Buildup for

7. Dimension shown is for lap splice option. For mechanical coupler option, this dimension

stepped MSE

is 5-8".
2"

6"

Welded Wire Reinforcement will conform to ASTM A 497.

45

M in.

Wall Panels

8. The Contractor may use Welded Wire Reinforcement when approved by the Engineer.

M ax.

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06120-3of3.
dgn

Transfer Devices at

6"

Bars 5L @ 1-0" sp.

1" Dowel Load

(0" min.,
11" m
Coping

Expanded
Polystyrene (b")

ESTIMATED QUANTITIES FOR C-I-P COPING

6"

BUILDUP FOR STEPPED MSE WALL PANELS


rd960rh

ITEM

Concrete

UNIT

QUANTITY

CY/LF

0.322

AND C-I-P COPING

NOTES:
1. Match roadway curb shape (Type) and height. See Roadway Plans and Index No. 300. 6-8" dimension is based

Bars 5T, 5X and 5S (Typ.)

on a 32" Vertical Shape Traffic Railing with a Type D curb adjacent to a 6-0" wide sidewalk. Adjust this dimension
LB/LF

28.85

as required for other curb types or transitions at Begin or End Retaining Wall.
2. See Index No. 422 and Index No. 423 for Bars 5S, 5T & 5X and Bullet Railing details. Adjust vertical dimension of

Additional Reinf. @ Expansion Joints

LB

32.04

Bars 5T and 5X, see Reinforcing Steel Note 5.

The above concrete quantities are based on a Type D


Concrete Curb on an MSE Wall (See Note 1).

LAST
REVISION

01/01/12

REVISIO N

12/30/2011

9:
35:
01 AM

Reinforcing Steel (Typical) excluding

DESCRIPTION:

FDOT DESIGN STANDARDS


FY 2012/2013

INDEX

WALL COPING WITH TRAFFIC RAILING/RAISED


SIDEWALK

NO.

6120

SHEET
NO.

(
C-I-P Traffic Railing)

COPING/ COPING
RAILING

42" Vertical Shape

Precast Coping ~ 9-6"

3
-6" ~ 42" Vertical Shape

C-I-P

2
-8" ~ 32" Vertical Shape

PRECAST

32" Vertical Shape

1-3"

2
-3" C-I-P Coping

SIZE

1-1"

6-6"

MARK

6-8"

Bars 5B2
b " V-Groove (Typ.)

b " V-Groove (See

2" Cover

Bars 5A @ 1-0" sp.

Note 3 & Detail "C")

Sides (Typ.)

(tied to Bars 5L (Typ.)

Approach Slab
(See Note 8)

" Preformed
Expansion Joint Filler

2
-2" M in.

b " V-Groove (Typ.)

Lap Splice

PRECAST COPING

Edge of

" Preformed

Precast

Expansion Joint Filler

Coping

C-I-P COPING
DETAIL "C"
(Showing Locations of b " V-Grooves and
Field cut reinforcing as required

" Open Joint

" Preformed Expansion Joint Filler)

" Open Joint

to maintain minimum cover (Typ.)


Spacing Bars 4P 5b "

1-0" Spacing (Typ.) (See Note 4)

30-0" Max. (See Note 3)

Bars 5B1

(tied to Bars 4P) (Typ.)


2" Cover @

Open Joints

Expansion Joints
Begin or End Retaining

" Expansion Joint Spacing ~ 50-0" Min., 90-0" Max. (See Note 1)

Wall, Precast Coping/


Parapet or C-I-P Coping

PARTIAL PLAN VIEW


(Skewed Approach Slab Shown, Perpendicular Approach Slab Similar)
(Precast Coping Shown, C-I-P Coping Similar) (Concrete Parapet not Shown for Clarity)

PRECAST COPING/PARAPET AND SIDEWALK NOTES:

1. Provide Class II concrete for slightly aggressive environments or


Class IV for moderately or extremely aggressive environments.

" Open Joint in

Precast Coping and


" Open Joint in

Concrete Parapet

)
.
n
"Mi
0

5
t(
e
p
a
r
e Pa
t
e
r
c
n
g & Co
n
i
p
tCo
s
a
c
e
lPr
a
c
i
p
y
"T
0

0
1

Precast Coping and


Concrete Parapet

2. Construct " Expansion Joints in sidewalk and C-I-P coping plumb

to coincide with
" Expansion Joint
in Sidewalk

perpendicular or radial to the Gutter Line. Provide at 90-0" maximum


intervals as shown.
3. Provide and install Preformed Expansion Joint Filler in accordance with

Top of Precast
Concrete Parapet

5. Spacing shown is along the Gutter Line.

Top of Retaining
Wall Panel (Typ.)

6. For Precast Coping only, Dowel Bars 4D are to extend 1-0" above the top
of retaining wall panel. Field cut as necessary to maintain 2" minimum cover

and spacing of Dowel Bars 4D.

Parapet

Concrete

-3"
2

to the top of the buildup concrete. See Wall Company Drawings for number

Top of C-I-P
Buildup Concrete

Coping

in the Concrete Parapet.

Coping

-0"
2

Coping only, V-Groove locations are to coincide with V-Groove locations

Top of Precast

Precast

between " Expansion Joints and/or Begin or End Sidewalk. For C

(
1
-0" M ax.
)

provide at 30-0" maximum intervals as shown. Space V-Grooves equally

Varies

4. Construct b" V-Grooves in sidewalk and C-I-P coping plumb and

Precast

Specification Section 932.

2" Cover M in.

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06130-1of2.
dgn

Coping

(tied to Bars 5U1) (Typ.)


Bars 5U1 @ 1-0" sp.

2" Cover @
b " V-Groove Spacing

Bars 5L @ 1-0" sp.

Bars 4P1 (Typ.)

in Precast Coping

7. Work this Index with the following:


Index No. 410 - Concrete Barrier Wall

9:
35:
02 AM

rd960rh

8. For C-I-P Coping only, work this Index with the following:
Bottom of

Index No. 820 - Pedestrian/Bicycle Railing.

Precast Coping

9. Finish Sidewalks in accordance with Specifications Section 522.


10. The following Indexes contain details of the intersection of the retaining

Clearance
Retaining Wall

Varies

(MSE Wall shown

wall at approach slabs:

Dowel Bars 4D

Index No. 20900 - Approach Slabs (Flexible Pavement Approaches)

(Typ.) (See Note 5)

other types similar)

Index No. 20910 - Approach Slabs (Rigid Pavement Approaches)

PARTIAL ELEVATION VIEW

12/30/2011

(Precast Coping and Sidewalk Reinforcing not Shown for Clarity)

LAST
REVISION

01/01/11

REVISIO N

(Precast Coping Shown, C-I-P Coping Similar)

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

WALL COPING/PARAPET WITH C-I-P SIDEWALK

NO.

6130

SHEET
NO.

REINFORCING STEEL BENDING DIAGRAMS - COPING/PARAPET AND SIDEWALK


Coping Line

Sidewalk
5-0" Min. Clearance

BILL OF REINFORCING STEEL


8"

Pedestrian/Bicycle Railing

1b "

Spacing Bars 4S1

MARK

SIZE

B1

9-6"

B2

AS REQD.

2-0"

P1

5-5"

N/A

S1

9-6"

N/A

U1

(Typ.)

1-0" sp.

2-2" Min.

(Typ.)

Lap Splice
Riding Surface

6" Sidewalk

See Detail "D"

Bars 5B1 (Typ.)

Top of Coping

9"

(See Note 5)

Bars 5L @
1-0" sp.

Bars 5B2
Spread Footing (See

@ 1-0" sp.

Index No. 410 for details)

Max. (Typ.)

Bars 5U1 @
1-0" sp.

1
-3"

Fill

3" 2 sp. @

10"

Dowels 4D

COPING

COPING

VARIES

N/A

Varies

15 Max.
C-I-P Buildup Concrete

"

Subbase.

Length as Required

4S1

Precast Coping ~ 9-6"

(See Wall Company

(
b " Min. ~ 2b " Max.)

6"
Min.

TYPICAL SECTION THRU PRECAST COPING/PARAPET WITH C-I-P SIDEWALK

Drawings for Details)

6"

N/A
VARIES

BARS 5A, 5B1, 5B2 & 4S1

N/A

7"

Retaining Wall Panel

" Std.

Panel width
+ 1-0"

Smooth or

Min.
See Note 1

BAR 5L

Textured Face

BAR 4P1

BAR 5U1

of Wall

AND RETAINING WALL (MSE Wall Shown, other Wall Types Similar)

REINFORCING STEEL NOTES:


1. All bar dimensions in the bending diagrams are out to out.
Pedestrian/Bicycle Railing

2. All reinforcing steel at expansion joints will have a 2" minimum cover.
3. Lap splices for Bars 5B2 will be a minimum of 2-2".

Concrete

4. For Precast Coping only, lap splice Bars 5L with Bars 5A. Lap splices will be a minimum

Barrier Wall
Coping

of 2-2".
5. For C-I-P only, see Index No. 820 for Bars 4P and 4S.

Sidewalk ~ 5-0" Min. Clearance

Gutter Line

6. The Contractor may use Welded Wire Reinforcement when approved by the Engineer.

Bars 4P @

Welded Wire Reinforcement must conform to ASTM A 497.

1-0" sp.
Back of Concrete

C-I-P Concrete Parapet

Barrier Wall

(See Index No. 820 & Note 4)

(
Se
e No
t
e2
)

(Typ.)

Top of C-I-P Coping/Sidewalk


(Const. Joint Required)

Bars 5L @ 1-0" sp.


1b "

Riding Surface

6" Sidewalk

See Detail "D"

(See Note 5)

Top of Coping

Barrier Wall

(Typ.)

Varies (2" Min.)


6"

15 Max.

Min.

9:
35:
03 AM

(Typ.)
It is the Contractors responsibility to

Seal with Poured

PRECAST COPING/PARAPET AND SIDEWALK NOTES:

Rubber or Low

1. Actual width varies depending on type of Retaining

Modulus Silicone
Sealant

(Top) & Expanded Polystyrene

minimum of 2" below the Stabilized

shown hatched (b" Side)

Wall used.
2. Match Cross Slope of Travel Lane or Shoulder.
3. Gradually deflect/displace Soil Reinforcement downward
as required. Soil Reinforcement is shown deflected
downward for illustrative purposes only and is not to

Sidewalk

scale. See Wall Company Drawings for details.


4. Concrete Parapet shown, Concrete Pedestrian/Bicycle
Railing (Index No. 825 & 826) similar. Complete
details and dimensions of Concrete Pedestrian/Bicycle

Varies (1-3"

b " Preformed

Max., 2" Min.)


Expansion Joint Filler

Railing are required in the Shop Drawings.


5. Match cross slope of connecting sidewalk or as
shown in the Wall Control Drawings.

Two Layers 30Lb. Roofing Felt

ensure Soil Reinforcement is placed a

Retaining Wall Panel

DETAIL "D"

(See Wall Company


Drawings for Details)

Subbase.
12/30/2011

5"

See Note 3

Bars 5B2

Stabilized Subbase

1-0" sp. Max.

Spacing

rd960rh

Index No. 410 for details)

2
-0"

Bars 5B2 @
Spread Footing (See

Recess

6"
45

Fill

1
-3" M ax.

6"

10"

Back of Concrete

"

2" Cover

C-I-P Coping

Sl
o
p
e Va
r
i
e
s

Varies

Roadway Pavement

3" M in.

Shoulder or

6"

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06130-2of2.
dgn

(Depth Varies ~ 1-0" Max.)

See Note 3

ensure Soil Reinforcement is placed a


minimum of 2" below the Stabilized

5B2

4"

Spacing Bars 5B1

It is the Contractors responsibility to

Precast Coping ~ 9-6"

AS REQD.

VARIES

(1-3" Max., 2" Min.)

(Typ.)

N/A

VARIES

Varies

Varies (2" Min.)

Stabilized Subbase

5B1

1
-8"

(
Se
e No
t
e2
)

2
-0"

Bars 5A @

6" 3"

2" Cover

C-I-P

2
-7"

Bars 4S1

Sl
o
p
e Va
r
i
e
s

PRECAST

C-I-P Coping

2" Min. Cover (Typ.)

Recess

Barrier Wall

Roadway Pavement

1
-0"

Back of Concrete

Precast Coping

2
-3" ~ Precast

1-0" sp.

Concrete Parapet
(
See Note 4)

Bars 4P1 @

Shoulder or

Precast Coping ~ Varies

1
-8"

Barrier Wall

Precast Coping

3"

Concrete
Gutter Line

5A

LENGTH

TYPICAL SECTION THRU C-I-P COPING WITH C-I-P SIDEWALK

Se
e No
t
e1

LAST
REVISION

01/01/12

REVISIO N

AND RETAINING WALL (MSE Wall Shown, other Wall Types Similar)

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

WALL COPING/PARAPET WITH C-I-P SIDEWALK

NO.

6130

SHEET
NO.

LIGHT PEDESTAL NOTES:

1.

The pedestal and junction slab are designed to resist the following working loads from the light
pole applied at the top of the Pedestal:

6-5" Min. (Pull Box Side) (See Note 9)

Axial Deadload

Wind load Moment about Transverse Axis (*)

40.60 kip-ft

Wind load Moment about Longitudinal Axis (*)

28.30 kip-ft

Dead load Moment about Longitudinal Axis (*)

1.690 kip-ft

Maximum Shear

1.380 kip

Torsion about Pole Axis

3.560 kip-ft

(*)

4-6" Min. (See Note 9)

Varies (Transition to

Varies (Transition to

1-9" Thick Junction Slab)

1-9" Thick Junction Slab)

1.560 kip

- Axis refers to Bridge Axis.

2.

See Index No. 21200 for anchor bolt design and notes.

3.

The Contractor is responsible for ensuring the anchor bolt design is compatible with the light
pole base plate. Modifications to the anchor bolt design must be signed and sealed by the
Contractors Specialty Engineer and submitted to the Engineer for approval prior to construction.

Junction Slab

Junction Slab

Length of 1-6" Thick Junction Slab ~ 7-6"

4.

Install Anchor Bolts plumb.

5.

For conduit, pull box and expansion/deflection fitting details, see Utility Conduit Detail Drawings.

6.
12 Bars 4J & 4M1 (Top & Bottom) @ 8"

The cost of anchor bolts, nuts, washers and anchor plates will be included in the Bid Price for
Light Poles. Include the cost of all labor, concrete and reinforcing steel required for construction
of the pedestals, pull boxes and miscellaneous hardware required for the completion of the electrical

Bars 5B3

system in the Bid Price for either the Traffic Railing or Concrete Parapet that the pedestal is

Field Cut Bars 4M2 as required to maintain clearance.

Bars 4J

8.

Anchor Bolt pattern orientation will be as shown.

& 4M1

9.

Slip Forming Method of construction requires the Engineers approval within the limits shown.

10. Reinforcing shown for light pole pedestals is in addition to typical reinforcing for C-I-P Junction
Slabs and Raised Sidewalks.

Bars 5B3 spaced @

11. Work this Index with the following as appropriate:


Index No. 6110
Index No. 6120
Index No. 6130

Construction

2 ~ 2" Conduits

Gutter Line (shown)


or Front Face of
Concrete Parapet

1
-8"

Joint

Spacing for Bars

(See Note 5)

4G4 & 4G5 (


pairs)

12. For Estimated Quantities, see Sheet No. 3.

Pul

Traffic Railing or
Concrete Parapet

1 ~ 1b " Conduit

912"

Light

Bars 4H
Anchor Bolt Circle
2" Cover (Typ.)

1-1b " (See Note 8)

2
-6"

Bars 4M2 (See Note 7)

Bars 4G4 (pairs)

3 sp. @

Bars 4G1 (pairs)

Bars 4G3 (pairs) (Typ.)

C-I-P Pedestal

6"

Bars 4G2 (pairs) (Typ.)

1
-1b "

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06200-1of3.
dgn

1
-0"

behind.
7.

Coping

Bars 4G5 (pairs)


2 sp. @ 6"

rd960rh

2 sp. @ 6"

1-1"

Spacing for Bars

5"

5 sp. @ 6"

5"

1-1"

4G1, 4G2, 4G3 & 4M2


2-6"

2-6"

2-6"
Expansion Joi
Junction Slab, Raised

9:
35:
04 AM

C-I-P Pedestal & Lig

4-6" Min.

Sidewalk or Sidewalk

PLAN VIEW
12/30/2011

(Junction Slab reinforcing not shown for clarity)

LAST
REVISION

01/01/11

REVISIO N

(Junction Slab Shown, Raised Sidewalk or Sidewalk Similar)

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

COPING MOUNTED LIGHT POLE PEDESTAL

NO.

6200

SHEET
NO.

9-0b"

1-6b "

5-0"

2-6"

1-4b "

1-1b "

C-I-P Traffic Railing (32" F-Shape Shown,


Other Traffic Railings Similar)

Coping
Light

Gutter Line (shown)


or Front Face of
Concrete Parapet

1b " Conduit

2" Conduits
Top of Junction Slab,
Bars 5V2 @ 8" sp.

Raised Sidewalk or
Sidewalk (See Note 4)

Top of C-I-P Coping

(See Note 6)

(Const. Joint Required)


Slope C-I-P Pedestal Surface

Shoulder or
Riding Surface

Roadway Pavement

Longitudinally with Profile Grade

"

(
Se
e No
t
e4
)

Bars 4G1 (pairs)

"

Elevation

(Typ.)

2
-0"

6"

Bars 4G5
(pairs)

C-I-P Pedestal

6"

Bars 5B3

Spacing

Bars 4M1
4" Cover (Bottom)

@ 8" sp.

2" Cover (Top & Sides)

3"

Bars 4H1
Bars 5B3

1
-9"

Bars 4H2

(
See Note 2)

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06200-2of3.
dgn

Top of Coping

Bars 4G4 (pairs)

Bars 5S (See Note 6)

Sl
o
p
e Va
r
i
e
s

Varies

Construction

(1-1" Max., 3" M

Joint

Bars 4M2 @ 6" sp.

Permitted

Bars 4J @ 8" sp. (tie to Alternate Bars 4A

Bars 4G4 (pairs) (Typ.)

in Junction Slab) (See Note 3)


Retaining Wall
3" Min.

Two Layers 30Lb. Roofing Felt

(Type Varies)
Expanded Polystyrene shown
4 sp. @ 1-0" = 4-0"

Spacing

hatched (b" Each Side)

Bars 5B3

See

6"

Note 5

Smooth or
Textured Face
of Retaining Wall

TYPICAL SECTION AT LIGHT POLE PEDESTAL


(Traffic Railing Shown, Concrete Parapet Similar)
(Junction Slab Shown, Raised Sidewalk or Sidewalk Similar)

rd960rh

NOTES:
1.

Provide Concrete Class to match adjacent coping.

2.

For junction slabs, increase the 1-0" depth dimension to 1-9". For sidewalks
see Index No. 6130 for C-I-P Coping, but increase 6" depth dimension to 1-6". The
minimum length of the Junction Slabs, Raised sidewalks and Sidewalks is

9:
35:
10 AM

30-0", measured along the Gutter Line.


3.

Bars 4J are only required when pedestals are behind a Traffic Railing.

4.

Match the slope of the adjoining junction slab and shoulder or roadway pavement,
raised sidewalk or sidewalk.
Actual width varies depending on type of Retaining Wall used.

6.

See Index No. 6110 for Bars 5V2 and 5S.

LAST
REVISION

01/01/12

REVISIO N

12/30/2011

5.

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

COPING MOUNTED LIGHT POLE PEDESTAL

NO.

6200

SHEET
NO.

REINFORCING STEEL BENDING DIAGRAMS - LIGHT POLE PEDESTAL


5-0" Max. (Left or Right)

7-2"

G1

16

5-8"

G2

4-8"

G3

4-2"

G4

8-10"

G5

7-4"

H1

9-8"

H2

13-8"

12

6-0"

M1

12

5-10"

M2

10

3-8"

2
-0"

3"

Wall Coping

2-6"

Varies (Transition to

BAR 4H2

2-7"

7-6" (Length of 1-6" Thick Junction Slab)

Junction Slab

Minimum Limits of C-I-P Coping

2-6"

4G1

2-0"

4G2

1-9"

4G3

3-8"

4G4

2-11"

4G5

ELEVATION VIEW
(Junction Slab Reinforcing & Bars 4J not Shown for Clarity)
(Traffic Railing Shown, Concrete Parapet Similar)

4G4 & 4G5

Junction Slab

2-4"

2-7"

BAR 4H1

1-9" Thick Junction Slab)


4G1, 4G2 & 4G3

1-9" Thick Junction Slab)

2-7"

4M1

5-0"

4M2

2-2"

10"

(Junction Slab Shown, Raised Sidewalk or Sidewalk Similar)

1b " Conduit

4M 2

2-6"

Bottom of MSE

(See Note 1)

2-4"

4M 1

2-6"

Varies (Transition to

Bars 4M2

2-7"

1
-5b "

2" Cover (Top & sides)

BARS 5B3 & 4J

1
-6"

Bottom of Thickened Junction Slab

7b "

(pairs) (Typ.)

4" Cover (Bottom)

BARS 4G1, 4G2, 4G3,

Light Pole

Wire Screen

NOTES:

(See Spec. 649-6)

1. Field Cut Bars 4M2 as required to maintain minimum cover.

2" Conduit

Light Pole Base

4G4 & 4G5

(See Note 2)

REINFORCING STEEL NOTES:


1. All bar dimensions in the bending diagrams are out to out.
2. Lap splices for Bars 4G1, 4G2 & 4G3 will be a minimum of 1-4". Lap

Dia.
M ax.

Leveling Nut

BAR 4M1 & 4M2

2. Maximum clearance between leveling nut and top of pedestal


will not exceed anchor bolt diameter.

Plate (Level)
1 ~ Bolt

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06200-3of3.
dgn

Bars 4H1

Bars 4G4

Bottom of C-I-P Pedestal

6-0"

2
-7"

45 (Typ.)

Varies

Bars 4G5 (pairs) (Typ.)

2b "

Bars 4G3 (pairs) (Typ.)

Junction Slab

3 sp.

(pairs)

Coping)

Bars 4G1

Bars 4G2 (pairs) (Typ.)


Top of recess
& Bottom of

6"

Bars 4H2

2
-3"

See Detail "A"

2" Conduit

(
C-I-P/Precast

1b " Conduit

(
C-I-P Pedestal)

Spacing Bars 4H

Pul

4J

2
-0"

B3

2
-7"

SIZE

2
-7"

NO. REQD. LENGTH

MARK

and Light

7-2"

2
-0"

Top of Traffic Railing

C-I-P Pede

5B3

2
-7"

BILL OF REINFORCING STEEL

splices for Bars 4G4 & 4G5 will be a minimum of 1-8".


3. The Contractor may use Welded Wire Reinforcement when approved by the
Engineer. Welded Wire Reinforcement will conform to ASTM A 497.

ESTIMATED QUANTITIES

ITEM

UNIT

QUANTITY

Concrete (Pedestal)

CY

0.926

Concrete (Thickened Junction Slab)

CY

1.222

Reinforcing Steel

LB

349

Washer
Slope C-I-P Pedestal

(Typ.)

rd960rh

Surface Longitudinally
with Profile Grade

Anchor Plate

9:
35:
11 AM

Anchor Bolts

(The quantities above are for one C-I-P Light Pole Pedestal. The
concrete quantity for the thickened junction slab is based on a
6" increase in thickness and a 5" wide retaining wall panel.
Adjust thickened concrete quantity as required for raised sidewalks

12/30/2011

and sidewalks.)

LAST
REVISION

01/01/12

REVISIO N

DETAIL "A"

DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

COPING MOUNTED LIGHT POLE PEDESTAL

NO.

6200

SHEET
NO.

REINFORCING STEEL BENDING DIAGRAMS - DRAINAGE


Barrier Wall

BILL OF REINFORCING STEEL

Expansion Joi
10-0" Min.

MARK

Sidewalk or Sidewalk,
C-I-P Coping and

12 ~ Bars 4S2 @ 8" sp.

Bars 5B2 (Field Cut as

8"

Junction Slab, Raised

REQD. SIZE

LENGTH
4b"

S2

12

3-1"

S3

10-0"

U2

VARIES

U3

12-10"

6-0"

Concrete Parapet

6"

Bars 5S3

1" Preformed Expansion

6"

Joint Filler (Typ. all Sides)

1
-6"

Bars 5C (Top)
(Typ.)

1
-6"

6"

Wall Inlet) (Typ.)

6"

required to clear Barrier

4b "

Traffic Railing or

STIRRUP BAR 4S2

Barrier Wall Inlet (Grate


Bars 5U3

5
-0"

not shown for clarity)

1-6"

(See Index No. 218 for

5-9"

1-6"
Varies

details)

BAR 5S3
2" Cover
(Typ. all Sides)

3
-7"

Bars 4L (Bottom)
(Typ.)

1
-9"

Gutter Line

Bars 4A (Top)
5-8"

C:
\d\projects\standards\structures\current\ready4release\2012book_draft\06201-1of1.
dgn

(Typ.)

BAR 5U3

Bars 5S

Coping

Bars 5V2 (Typ.)

BAR 6U2

REINFORCING STEEL NOTES:


8 ~ Bars 6U2

Bars 6U2

1. All bar dimensions in the bending diagrams are out to out.

@ 8" sp. (See Note 1)

2. All reinforcing steel at open joints will have a 2" minimum cover.
3. See Index Nos. 6110, 6120 & 6130 for Bars 4A (or 5A), 5B, 5C and 4L (or 5L).

PLAN VIEW

4. The Contractor may use Welded Wire Reinforcement when approved by the

(Junction Slab Shown, Raised Sidewalk Similar)

Engineer. Welded Wire Reinforcement will conform to ASTM A 497.

7-0b" (See Note 2)


NOTES:

Gutter Line

Bars 5V2

(32" F-Shape shown,

(See Note 4)

42" F-Shape similar)

and Grate (See

for details)

Top of C-I-P Coping

"

"

Const. Joint Required

15 ~ Bars 4S2 @ 6" spacing for Raised Sidewalks).


3" Cover

4"

Em bed.

7"

6" M in.

3. Actual location & width vary depending on type of Retaining Wall used.

See Note 5

6"

Coping

Bars 5U3 (Rotate as required


Bars 6U2

6"

to clear junction slab reinforcing)

Bars 5B2

Bars 5B2 (Typ.)

4"

rd960rh

@ 8" sp.
1" Preformed Expansion
Joint Filler (Typ.)

4" Cover (Bottom)


9:
35:
12 AM

4. See Index No. 6110 for Bars 5V2 and 5S.


5. Two Layers 30Lb. Roofing Felt (Top) & Expanded Polystyrene shown hatched
(b" Each Side).
6. Locate Barrier Wall Inlet a minimum of 10-0" away

Expansion Joints in Junctions Slab, Raised Sidewalk or Side


C-I-P Coping and Traffic Railing or Concrete Parapet.

7. Work this Index with the following as appropriate:


Index No. 6110
Index No. 6120
Index No. 6130

Retaining Wall (MSE Wall

Compacted Sand
2" Cover (Top & Sides)

Shown, other Wall Types Similar)


2" Cover

2" Cover

See

SECTION A-A
12/30/2011

for C-I-P Raised Sidewalk and Sidewalks.

Bars 5B2

Bars 4S2 @ 8" sp.

Bars 5S3

2. Dimensions shown are for junction slab. Increase width as required

Spacing

Bars 5S (See Note 4)

1
-0"

Junction Slab. For C-I-P Raised Sidewalks or Sidewalks, match bar


spacing and size shown in Typical Sections (i.e., 11 ~ Bars 5U2 and

2
-3"

Index No. 218


Riding Surface

1. Spacing shown is along the Gutter Line. Spacing shown is for C-I-P

Recess

Barrier Wall Inlet

1
0 "

(See Note 2)

Roadway Pavement

C-I-P Traffic Railing

Varies (
10 "

Shoulder or

1-6b " Min.

M ax.
, 3" M in.
)

4-5b "

1-0b"

SECTION THRU JUNCTION SLAB, BARRIER WALL INLET AND RETAINING WALL

6"

Note 2

LAST
REVISION

01/01/12

REVISIO N

(Junction Slab Shown, Raised Sidewalk Similar)


DESCRIPTION:

INDEX

FDOT DESIGN STANDARDS


FY 2012/2013

JUNCTION SLAB AT DRAINAGE INLET OPENINGS

NO.

6201

SHEET
NO.