Sie sind auf Seite 1von 51

NAPHTA PRODUCT COOLER EXTERNAL INSPECTION CHECKLIST

INSPECTION UNIT

DESCRIPTION
Inspection Date
Last Inspection
Date

Plant No.
Equipment No.
Service
NO.

DESCRIPTION

External Appearance of Vessel:


a) Clean fins (no significant dust accumulation)
b) Cleanliness of fins found acceptable as it is
c) Cleanliness of fins found acceptable after
washing with detergent and water
d) Properly screwed plugs
e) Top of fin tube bundle clean
f) Fan blades in good condition
g) Fan box/plenum (if any) in good condition
1

h)

Equipment identification and number available

i)
j)

Name plate available and readable


Nozzles in good condition

k)

Coating in good condition, (if no, check below)


(i)
(ii)
(iii)
(iv)
(v)

Isolated coating failure


Widespread coating failure
General Corrosion
Isolated pitting
Widespread pitting

Supports:
a) Bolts properly installed and in good condition
b) Support structures in good condition
c)

Welds on structural support(s) in good condition

d) Non-restrained end is free to move


Nozzles/Flanges:
3

a)

Nozzle and flanges in good condition (no leak)

b) Bolts and nuts in good condition


c) Flanges in good alignment
Drain/Vent/Blinds/Lifting Lugs:
a) Drain/vent plug(s) installed
b) Nipples/root valve(s) seal welded
c) Drain valve blinded at end
d) Spectacle blind installed for positive isolation

Yes

4
e) Corrosion on the drain/vent nipple or other
fittings
f) Lifting lugs in good condition
Miscellaneous Items:
a) Instrumentation:
(i)
Pressure gage(s) in good condition
(ii)

a)

(i)
Tags for gages installed
(ii)
Thermowells thread properly engage
(iii) Thermal relief valve(s) in good
condition
Relief Valves:

b)

Connected Piping:

(i)

INSPECTED BY
PIRECO-EPC CONTRACTOR
VENDOR-(NAME)
SOC-PROJECT

SOC-PR0CESS
SOC -OPERAION

Temperature gage(s) in good condition

Acceptable per SAEP 319 checklist

(i)
Drain/vent /welding boss/RV piping in
good condition
(ii)
Piping flow direction arrow stenciled
(iii) Piping identification stenciled
(iv) Adequate supports (no vibration)
(v)
Smooth fluid flow (no vibration)
Access Ladder/Platforms/Walkways:
a) Platform/ladder/stairway/handrails in good
condition
b) Gratings in good condition
c) Bolts/clips on grating
d) Safety drop-bar(s) in good condition
e) Stairway tread(s) in good condition
f) Non-seal welded structural members in good
condition (no corrosion scales build up)
g) Stairway access color-coded
h) Ladder rung(s) in good condition
i) Cage(s) in good condition
j) Platform(s) clean (no debris accumulation)
NAME

DATE

XTERNAL INSPECTION CHECKLIST

DESCRIPTION

CHECKLIST
Naphtha Cooler-E772A/B/C

Inspection Date
Last Inspection
Date

No

N/A

REMARKS

DATE

SIGNATURE

REBOILER EXTERNAL INSPECTION CHECKLIST

INSPECTION UNIT

DESCRIPTION
Inspection Date
Last Inspection
Date

Plant No.
Equipment No.
Service
NO.

DESCRIPTION

External Appearance of Vessel:


a)
Mechanically sound (no damages such as
scratches, grooves, dents)
b)

Equipment identification and number available

c)
Name plate available and readable
d) Tight Nozzles (no leaks)
e)
Good welds (no cracks)
f)
Good coating appearance (no discoloration due
to overheating)
g)
Good alignment
h) Good surface appearance (no signs of blisters or
bulges)
i)

Good coating (no failure; if no , check below :)

(i) Isolated coating failure


(i)
Widespread coating failure
(ii)
General corrosion
(iii) Isolated pitting
(iv) Widespread pitting
Vessel Skirts/Supports:
a) Skirt mechanically sound
b) Skirt coating good
c) Skirt clean inside
d) Support sliding pad good condition
e) Saddle shoe aligned with the supports
f) Support guides available and mechanically sound
2

g) Welds on structure support(s)


h) Pipe support base /I beam in good condition ( no
gap)
i) Structure component(s) in good condition
j) Space between the saddle base and support beam
clean (no rust scales)
k) Dummy leg support in good condition
l) Base plate(s) in good condition

Yes

m) Non-restrained end is free to move


Nozzles /Flanges:
a) Nozzle and flanges in good condition (no leak)
b) No corrosion between flanges
c) Flanges no signs of mechanical damage
d) Uneven or loose stud bolts
e) Stud bolts of proper length
f) Bolts and nuts in good condition
g) Weep holes of reinforcing pad properly greased
Drain/Vent/Lifting Lugs:
a) Drain/vent plug available
b) Nipples/root valve properly seal welded
c) Weep holes of reinforcing pads in good condition (no
signs of leak)
d) Welds on reinforcing pads in good condition
e) Drain valve blinded at end
f) Spectacle blind installed for positive isolation
g) Drain/vent nipple or other fittings in good condition
h) Davits/lifting lugs fully operational
Isolation Valves:
a) Proper rating installed
b) Gland in good condition
c) Gland stud/eye bolt in good condition
d) Hand wheel in good condition
e) Valve body in good condition
f) Horizontal Valve position indicator with safety caution

Hot/Cold Insulation:
a) Metal jackets and insulation (hot) in good condition
b) Aluminum cladding, vapor barrier and insulation
(cold) in good condition
c) Correct insulation material/sufficient thickness
d) Insulation straps properly installed
e) Insulation at OSI points covered
Miscellaneous Items:
a) Instrumentation:
(i) Pressure gage(s) in good condition
(ii) Temperature gage(s) in good condition
(iii) Tags for gages installed properly
(iv) Thermowells thread properly engage
(v)

Thermal relief valve(s) in good condition

b)

Relief Valves:
(i) Acceptable per SAEP 319 checklist

c)

Connected Piping:

(i)
Drain/vent /welding boss/RV piping in
good condition
(ii) Piping flow direction arrow stenciled
(iii) Piping identification stenciled
(iv) Adequate supports (no vibration)

INSPECTED BY
PIRECO-EPC CONTRACTOR
VENDOR-(NAME)
SOC-PROJECT

SOC-PR0CESS
SOC -OPERAION

(v) Smooth fluid flow ( no vibration)


Access Ladder/Platforms/Walkways:
a) Platform/ladder/stairway/handrails in good
condition
b) Gratings in good condition
c) Bolts/clips on grating installed properly
d) Safety drop-bar(s) in good condition
e) Stairway tread(s) in good condition
f) Non-seal welded structural members in good
condition (no corrosion scales build up)
g) Stairway access color-coded
h) Ladder rung(s) in good condition
i) Cage(s) in good condition
j) Platform(s) clean (no debris accumulation)
NAME

DATE

INSPECTION CHECKLIST

DESCRIPTION

CHECKLIST
Reboilerr-E770

Inspection Date
Last Inspection
Date

No

N/A

REMARKS

DATE

SIGNATURE

STEAM CONDENSATE COOLER EXTERNAL INSPECTION CHECKLIST

INSPECTION UNIT

DESCRIPTION
Inspection Date
Last Inspection
Date

Plant No.
Equipment No.
Service
NO.

DESCRIPTION

External Appearance of Vessel:


a) Clean fins (no significant dust accumulation)
b) Cleanliness of fins found acceptable as it is
c) Cleanliness of fins found acceptable after
washing with detergent and water
d) Properly screwed plugs
e) Top of fin tube bundle clean
f) Fan blades in good condition
g) Fan box/plenum (if any) in good condition
1

h)

Equipment identification and number available

i)
j)

Name plate available and readable


Nozzles in good condition

k)

Coating in good condition, (if no, check below)


(i)
(ii)
(iii)
(iv)
(v)

Isolated coating failure


Widespread coating failure
General Corrosion
Isolated pitting
Widespread pitting

Supports:
a) Bolts properly installed and in good condition
b) Support structures in good condition
c)

Welds on structural support(s) in good condition

d) Non-restrained end is free to move


Nozzles/Flanges:
3

a)

Nozzle and flanges in good condition (no leak)

b) Bolts and nuts in good condition


c) Flanges in good alignment
Drain/Vent/Blinds/Lifting Lugs:
a) Drain/vent plug(s) installed
b) Nipples/root valve(s) seal welded
c) Drain valve blinded at end
d) Spectacle blind installed for positive isolation

Yes

4
e) Corrosion on the drain/vent nipple or other
fittings
f) Lifting lugs in good condition
Miscellaneous Items:
a) Instrumentation:
(i)
Pressure gage(s) in good condition
(ii)

a)

(i)
Tags for gages installed
(ii)
Thermowells thread properly engage
(iii) Thermal relief valve(s) in good
condition
Relief Valves:

b)

Connected Piping:

(i)

INSPECTED BY
PIRECO-EPC CONTRACTOR
VENDOR-(NAME)
SOC-PROJECT

SOC-PR0CESS
SOC -OPERAION

Temperature gage(s) in good condition

Acceptable per SAEP 319 checklist

(i)
Drain/vent /welding boss/RV piping in
good condition
(ii)
Piping flow direction arrow stenciled
(iii) Piping identification stenciled
(iv) Adequate supports (no vibration)
(v)
Smooth fluid flow (no vibration)
Access Ladder/Platforms/Walkways:
a) Platform/ladder/stairway/handrails in good
condition
b) Gratings in good condition
c) Bolts/clips on grating
d) Safety drop-bar(s) in good condition
e) Stairway tread(s) in good condition
f) Non-seal welded structural members in good
condition (no corrosion scales build up)
g) Stairway access color-coded
h) Ladder rung(s) in good condition
i) Cage(s) in good condition
j) Platform(s) clean (no debris accumulation)
NAME

DATE

EXTERNAL INSPECTION CHECKLIST

DESCRIPTION

CHECKLIST
Steam Condensing Cooler-E774

Inspection Date
Last Inspection
Date

No

N/A

REMARKS

DATE

SIGNATURE

COMPRESSOR AFTER COOLER EXTERNAL INSPECTION CHECKLIST

INSPECTION UNIT

DESCRIPTION
Inspection Date
Last Inspection
Date

Plant No.
Equipment No.
Service
NO.

DESCRIPTION

External Appearance of Vessel:


a) Clean fins (no significant dust accumulation)
b) Cleanliness of fins found acceptable as it is
c) Cleanliness of fins found acceptable after
washing with detergent and water
d) Properly screwed plugs
e) Top of fin tube bundle clean
f) Fan blades in good condition
g) Fan box/plenum (if any) in good condition
1

h)

Equipment identification and number available

i)
j)

Name plate available and readable


Nozzles in good condition

k)

Coating in good condition, (if no, check below)


(i)
(ii)
(iii)
(iv)
(v)

Isolated coating failure


Widespread coating failure
General Corrosion
Isolated pitting
Widespread pitting

Supports:
a) Bolts properly installed and in good condition
b) Support structures in good condition
c)

Welds on structural support(s) in good condition

d) Non-restrained end is free to move


Nozzles/Flanges:
3

a)

Nozzle and flanges in good condition (no leak)

b) Bolts and nuts in good condition


c) Flanges in good alignment
Drain/Vent/Blinds/Lifting Lugs:
a) Drain/vent plug(s) installed
b) Nipples/root valve(s) seal welded
c) Drain valve blinded at end
d) Spectacle blind installed for positive isolation

Yes

4
e) Corrosion on the drain/vent nipple or other
fittings
f) Lifting lugs in good condition
Miscellaneous Items:
a) Instrumentation:
(i)
Pressure gage(s) in good condition
(ii)

a)

(i)
Tags for gages installed
(ii)
Thermowells thread properly engage
(iii) Thermal relief valve(s) in good
condition
Relief Valves:

b)

Connected Piping:

(i)

INSPECTED BY
PIRECO-EPC CONTRACTOR
VENDOR-(NAME)
SOC-PROJECT

SOC-PR0CESS
SOC -OPERAION

Temperature gage(s) in good condition

Acceptable per SAEP 319 checklist

(i)
Drain/vent /welding boss/RV piping in
good condition
(ii)
Piping flow direction arrow stenciled
(iii) Piping identification stenciled
(iv) Adequate supports (no vibration)
(v)
Smooth fluid flow (no vibration)
Access Ladder/Platforms/Walkways:
a) Platform/ladder/stairway/handrails in good
condition
b) Gratings in good condition
c) Bolts/clips on grating
d) Safety drop-bar(s) in good condition
e) Stairway tread(s) in good condition
f) Non-seal welded structural members in good
condition (no corrosion scales build up)
g) Stairway access color-coded
h) Ladder rung(s) in good condition
i) Cage(s) in good condition
j) Platform(s) clean (no debris accumulation)
NAME

DATE

EXTERNAL INSPECTION CHECKLIST

DESCRIPTION

CHECKLIST
Compressor After Cooler-E773

Inspection Date
Last Inspection
Date

No

N/A

REMARKS

DATE

SIGNATURE

HEAT EXCHANGER EXTERNAL INSPECTION CHECKLIST

INSPECTION UNIT

DESCRIPTION
Inspection Date
Last Inspection
Date

Plant No.
Equipment No.
Service
NO.

DESCRIPTION

External Appearance of Vessel:


a)
Mechanically sound (no damages such as
scratches, grooves, dents)
b)

Equipment identification and number available

c)
Name plate available and readable
d) Tight Nozzles (no leaks)
e)
Good welds (no cracks)
f)
Good coating appearance (no discoloration due
to overheating)
g)
Good alignment
h) Good surface appearance (no signs of blisters or
bulges)
i)

Good coating (no failure; if no , check below :)

(i) Isolated coating failure


(i)
Widespread coating failure
(ii)
General corrosion
(iii) Isolated pitting
(iv) Widespread pitting
Vessel Skirts/Supports:
a) Skirt mechanically sound
b) Skirt coating good
c) Skirt clean inside
d) Support sliding pad good condition
e) Saddle shoe aligned with the supports
f) Support guides available and mechanically sound
2

g) Welds on structure support(s)


h) Pipe support base /I beam in good condition ( no
gap)
i) Structure component(s) in good condition
j) Space between the saddle base and support beam
clean (no rust scales)
k) Dummy leg support in good condition
l) Base plate(s) in good condition

Yes

m) Non-restrained end is free to move


Nozzles /Flanges:
a) Nozzle and flanges in good condition (no leak)
b) No corrosion between flanges
c) Flanges no signs of mechanical damage
d) Uneven or loose stud bolts
e) Stud bolts of proper length
f) Bolts and nuts in good condition
g) Weep holes of reinforcing pad properly greased
Drain/Vent/Lifting Lugs:
a) Drain/vent plug available
b) Nipples/root valve properly seal welded
c) Weep holes of reinforcing pads in good condition (no
signs of leak)
d) Welds on reinforcing pads in good condition
e) Drain valve blinded at end
f) Spectacle blind installed for positive isolation
g) Drain/vent nipple or other fittings in good condition
h) Davits/lifting lugs fully operational
Isolation Valves:
a) Proper rating installed
b) Gland in good condition
c) Gland stud/eye bolt in good condition
d) Hand wheel in good condition
e) Valve body in good condition
f) Horizontal Valve position indicator with safety caution

Hot/Cold Insulation:
a) Metal jackets and insulation (hot) in good condition
b) Aluminum cladding, vapor barrier and insulation
(cold) in good condition
c) Correct insulation material/sufficient thickness
d) Insulation straps properly installed
e) Insulation at OSI points covered
Miscellaneous Items:
a) Instrumentation:
(i) Pressure gage(s) in good condition
(ii) Temperature gage(s) in good condition
(iii) Tags for gages installed properly
(iv) Thermowells thread properly engage
(v)

Thermal relief valve(s) in good condition

b)

Relief Valves:
(i) Acceptable per SAEP 319 checklist

c)

Connected Piping:

(i)
Drain/vent /welding boss/RV piping in
good condition
(ii) Piping flow direction arrow stenciled
(iii) Piping identification stenciled
(iv) Adequate supports (no vibration)

INSPECTED BY
PIRECO-EPC CONTRACTOR
VENDOR-(NAME)
SOC-PROJECT

SOC-PR0CESS
SOC -OPERAION

(v) Smooth fluid flow ( no vibration)


Access Ladder/Platforms/Walkways:
a) Platform/ladder/stairway/handrails in good
condition
b) Gratings in good condition
c) Bolts/clips on grating installed properly
d) Safety drop-bar(s) in good condition
e) Stairway tread(s) in good condition
f) Non-seal welded structural members in good
condition (no corrosion scales build up)
g) Stairway access color-coded
h) Ladder rung(s) in good condition
i) Cage(s) in good condition
j) Platform(s) clean (no debris accumulation)
NAME

DATE

RNAL INSPECTION CHECKLIST

DESCRIPTION

CHECKLIST
Heat Exchanger-E771 A/B

Inspection Date
Last Inspection
Date

No

N/A

REMARKS

DATE

SIGNATURE

COMPRESSOR DISCHARGE DRUM EXTERNAL INSPECTION CHECKLIST

INSPECTION UNIT

DESCRIPTION
Inspection Date
Last Inspection
Date

Plant No.
Equipment No.
Service

NO.

DESCRIPTION

External Appearance of Vessel:


a) Mechanically sound (no damages such as
scratches, grooves, dents)
b) Equipment identification and number available
c) Name plate available and readable
d) Tight nozzles (no Leaks)
e) Good welds ( no Cracks)
f) Good coating appearance ( no discoloration due to
overheating)
g) Good alignment
h) Good surface appearance ( no signs of blisters,
bulges)
i) Good coating (no failure; if no , check below:)
(i)
Isolated coating failure
(ii)
Widespread coating failure
(iii) General Corrosion
(iv) Isolated pitting
Vessel Skirts/Supports:
a) Skirt mechanically sound
b) Skirt coating good
c) Skirt clean inside
d) Fireproofing in good condition
e) Skirt drain is clean (no debris)
f) Support sliding pad good condition
g) Saddle shoe aligned with the supports
h)

Support guides available and mechanically sound

i)

Welds on structural support(s) in good condition

j) Pipe support base /I beam in good condition (no


gap)
k) Structural component(s) in good condition
l) Space between the saddle base and the support
beam clean ( no rust scales)
m) Dummy leg supports in good condition

Yes

n) Base plate(s) in good condition


Nozzles/Manways/Flanges:
a) Nozzle and flanges in good condition (no leak)
b) Special leak protection cover (caustic/chemical) in
good condition
c)
3

d) Flanges no signs of mechanical damage


e) Stud bolts tight
f) Stud bolts of proper length
g) Jack screws available and serviceable
h) Bolts and nuts in good condition
i)

Weep holes of reinforcing pad properly greased

Drain/Vent/Blinds/Lifting Lugs:
a) Drain/vent plug available
b) Nipples/root valve properly seal welded
c) Reinforcing pads in good condition (no signs of
leaks on weep holes)
d) Welds on reinforcing pads in good condition
e) Drain valve blinded at end
f) Spectacle blind installed for positive isolation
g) Drain/vent nipple or other fittings in good
condition
h) Davits/ lifting lugs fully operational
i) Dead legs not present or removed
5 Isolation Valves:
a) Proper rating
b) Gland in good condition
c) Gland stud/eye bolt in good condition
d) Hand wheel available and mechanically sound
e) Valve body in good condition
f) Horizontal valve position indicator with safety
caution
Hot/Cold Insulation:
a)

Flange coating in good condition (no corrosion)

Metal jackets and insulation (hot) good condition

b) Aluminum cladding, vapor barrier and insulation


(cold) in good condition
c) Correct insulation material/sufficient thickness
d) All insulation straps available and fully tight
e) Insulation at OSI points covered
Miscellaneous Items:
a) Instrumentation:
(i)
Pressure gage(s) in good condition
(ii)
Temperature gage(s) in good condition
(iii) Tags for gages available
(iv) Thermowells thread properly engage
(v)

Thermal relief valve(s) in good condition

(vi) Level sight glasses in good condition


Relief valves: (Use SAEP-319 Checklist)
(i)
Acceptable per SAEP 319 checklist
c) Connected piping:
(i)
Drain/vent /welding boss/RV piping in
good condition
(ii)
Piping flow direction arrow stenciled
(iii) Piping identification stenciled
(iv) Utility piping (steam etc.) has working
check valve
(v)
Corrosion monitoring Cosasco fitting
location marked
(vi) Piping adequately supported
(vii) Fluid flow smooth (no vibration)
Underground to Aboveground Transition Sections of
Vessel:
b)

INSPECTED BY
PIRECO-EPC CONTRACTOR
VENDOR-(NAME)
SOC-PROJECT

SOC-PR0CESS
SOC -OPERAION

a)

Coating of above ground section in good condition

b)

Coating on the transition section in good condition

c) Coating properly applied on buried or transition


section
d) Warning signs to indicate underground vessel
available
NAME

DATE

EXTERNAL INSPECTION CHECKLIST

DESCRIPTION

CHECKLIST
Discharge Drum-D 772

Inspection Date
Last Inspection
Date

No

N/A

REMARKS

DATE

SIGNATURE

COMPRESSOR SUCTION DRUM EXTERNAL INSPECTION CHECKLIST

INSPECTION UNIT

DESCRIPTION
Inspection Date
Last Inspection
Date

Plant No.
Equipment No.
Service

NO.

DESCRIPTION

External Appearance of Vessel:


a) Mechanically sound (no damages such as
scratches, grooves, dents)
b) Equipment identification and number available
c) Name plate available and readable
d) Tight nozzles (no Leaks)
e) Good welds ( no Cracks)
f) Good coating appearance ( no discoloration due to
overheating)
g) Good alignment
h) Good surface appearance ( no signs of blisters,
bulges)
i) Good coating (no failure; if no , check below:)
(i)
Isolated coating failure
(ii)
Widespread coating failure
(iii) General Corrosion
(iv) Isolated pitting
Vessel Skirts/Supports:
a) Skirt mechanically sound
b) Skirt coating good
c) Skirt clean inside
d) Fireproofing in good condition
e) Skirt drain is clean (no debris)
f) Support sliding pad good condition
g) Saddle shoe aligned with the supports
h)

Support guides available and mechanically sound

i)

Welds on structural support(s) in good condition

j) Pipe support base /I beam in good condition (no


gap)
k) Structural component(s) in good condition
l) Space between the saddle base and the support
beam clean ( no rust scales)
m) Dummy leg supports in good condition

Yes

n) Base plate(s) in good condition


Nozzles/Manways/Flanges:
a) Nozzle and flanges in good condition (no leak)
b) Special leak protection cover (caustic/chemical) in
good condition
c)
3

d) Flanges no signs of mechanical damage


e) Stud bolts tight
f) Stud bolts of proper length
g) Jack screws available and serviceable
h) Bolts and nuts in good condition
i)

Weep holes of reinforcing pad properly greased

Drain/Vent/Blinds/Lifting Lugs:
a) Drain/vent plug available
b) Nipples/root valve properly seal welded
c) Reinforcing pads in good condition (no signs of
leaks on weep holes)
d) Welds on reinforcing pads in good condition
e) Drain valve blinded at end
f) Spectacle blind installed for positive isolation
g) Drain/vent nipple or other fittings in good
condition
h) Davits/ lifting lugs fully operational
i) Dead legs not present or removed
5 Isolation Valves:
a) Proper rating
b) Gland in good condition
c) Gland stud/eye bolt in good condition
d) Hand wheel available and mechanically sound
e) Valve body in good condition
f) Horizontal valve position indicator with safety
caution
Hot/Cold Insulation:
a)

Flange coating in good condition (no corrosion)

Metal jackets and insulation (hot) good condition

b) Aluminum cladding, vapor barrier and insulation


(cold) in good condition
c) Correct insulation material/sufficient thickness
d) All insulation straps available and fully tight
e) Insulation at OSI points covered
Miscellaneous Items:
a) Instrumentation:
(i)
Pressure gage(s) in good condition
(ii)
Temperature gage(s) in good condition
(iii) Tags for gages available
(iv) Thermowells thread properly engage
(v)

Thermal relief valve(s) in good condition

(vi) Level sight glasses in good condition


Relief valves: (Use SAEP-319 Checklist)
(i)
Acceptable per SAEP 319 checklist
c) Connected piping:
(i)
Drain/vent /welding boss/RV piping in
good condition
(ii)
Piping flow direction arrow stenciled
(iii) Piping identification stenciled
(iv) Utility piping (steam etc.) has working
check valve
(v)
Corrosion monitoring Cosasco fitting
location marked
(vi) Piping adequately supported
(vii) Fluid flow smooth (no vibration)
Underground to Aboveground Transition Sections of
Vessel:
b)

INSPECTED BY
PIRECO-EPC CONTRACTOR
VENDOR-(NAME)
SOC-PROJECT

SOC-PR0CESS
SOC -OPERAION

a)

Coating of above ground section in good condition

b)

Coating on the transition section in good condition

c) Coating properly applied on buried or transition


section
d) Warning signs to indicate underground vessel
available
NAME

DATE

EXTERNAL INSPECTION CHECKLIST

DESCRIPTION

CHECKLIST
Suction Drum-D 771

Inspection Date
Last Inspection
Date

No

N/A

REMARKS

DATE

SIGNATURE

STEAM DISENGAGING DRUM EXTERNAL INSPECTION CHECKLIST

INSPECTION UNIT

DESCRIPTION
Inspection Date
Last Inspection
Date

Plant No.
Equipment No.
Service

NO.

DESCRIPTION

External Appearance of Vessel:


a) Mechanically sound (no damages such as
scratches, grooves, dents)
b) Equipment identification and number available
c) Name plate available and readable
d) Tight nozzles (no Leaks)
e) Good welds ( no Cracks)
f) Good coating appearance ( no discoloration due to
overheating)
g) Good alignment
h) Good surface appearance ( no signs of blisters,
bulges)
i) Good coating (no failure; if no , check below:)
(i)
Isolated coating failure
(ii)
Widespread coating failure
(iii) General Corrosion
(iv) Isolated pitting
Vessel Skirts/Supports:
a) Skirt mechanically sound
b) Skirt coating good
c) Skirt clean inside
d) Fireproofing in good condition
e) Skirt drain is clean (no debris)
f) Support sliding pad good condition
g) Saddle shoe aligned with the supports
h)

Support guides available and mechanically sound

i)

Welds on structural support(s) in good condition

j) Pipe support base /I beam in good condition (no


gap)
k) Structural component(s) in good condition
l) Space between the saddle base and the support
beam clean ( no rust scales)
m) Dummy leg supports in good condition

Yes

n) Base plate(s) in good condition


Nozzles/Manways/Flanges:
a) Nozzle and flanges in good condition (no leak)
b) Special leak protection cover (caustic/chemical) in
good condition
c)
3

d) Flanges no signs of mechanical damage


e) Stud bolts tight
f) Stud bolts of proper length
g) Jack screws available and serviceable
h) Bolts and nuts in good condition
i)

Weep holes of reinforcing pad properly greased

Drain/Vent/Blinds/Lifting Lugs:
a) Drain/vent plug available
b) Nipples/root valve properly seal welded
c) Reinforcing pads in good condition (no signs of
leaks on weep holes)
d) Welds on reinforcing pads in good condition
e) Drain valve blinded at end
f) Spectacle blind installed for positive isolation
g) Drain/vent nipple or other fittings in good
condition
h) Davits/ lifting lugs fully operational
i) Dead legs not present or removed
5 Isolation Valves:
a) Proper rating
b) Gland in good condition
c) Gland stud/eye bolt in good condition
d) Hand wheel available and mechanically sound
e) Valve body in good condition
f) Horizontal valve position indicator with safety
caution
Hot/Cold Insulation:
a)

Flange coating in good condition (no corrosion)

Metal jackets and insulation (hot) good condition

b) Aluminum cladding, vapor barrier and insulation


(cold) in good condition
c) Correct insulation material/sufficient thickness
d) All insulation straps available and fully tight
e) Insulation at OSI points covered
Miscellaneous Items:
a) Instrumentation:
(i)
Pressure gage(s) in good condition
(ii)
Temperature gage(s) in good condition
(iii) Tags for gages available
(iv) Thermowells thread properly engage
(v)

Thermal relief valve(s) in good condition

(vi) Level sight glasses in good condition


Relief valves: (Use SAEP-319 Checklist)
(i)
Acceptable per SAEP 319 checklist
c) Connected piping:
(i)
Drain/vent /welding boss/RV piping in
good condition
(ii)
Piping flow direction arrow stenciled
(iii) Piping identification stenciled
(iv) Utility piping (steam etc.) has working
check valve
(v)
Corrosion monitoring Cosasco fitting
location marked
(vi) Piping adequately supported
(vii) Fluid flow smooth (no vibration)
Underground to Aboveground Transition Sections of
Vessel:
b)

INSPECTED BY
PIRECO-EPC CONTRACTOR
VENDOR-(NAME)
SOC-PROJECT

SOC-PR0CESS
SOC -OPERAION

a)

Coating of above ground section in good condition

b)

Coating on the transition section in good condition

c) Coating properly applied on buried or transition


section
d) Warning signs to indicate underground vessel
available
NAME

DATE

XTERNAL INSPECTION CHECKLIST

DESCRIPTION

CHECKLIST
Steam Disengaging Drum-D 770

Inspection Date
Last Inspection
Date

No

N/A

REMARKS

DATE

SIGNATURE

STABILIZER TOWER EXTERNAL INSPECTION CHECKLIST

INSPECTION UNIT

DESCRIPTION
Inspection Date
Last Inspection
Date

Plant No.
Equipment No.
Service

NO.

DESCRIPTION

External Appearance of Columns:


a) Mechanically sound (no damages such as
scratches, grooves, dents)
b) Equipment identification and number available
c) Name plate available and readable
d) Tight nozzles (no leaks)
e) Good welds (no cracks)
f) Good coating appearance (no discoloration due to
overheating)
g) Good alignment
h) Good surface appearance (no signs of blisters,
bulges)
i) Good coating (no failure; if no , check below:)
(i)
Isolated coating failure
(ii)
Widespread coating failure
(iii) General corrosion
(iv) Isolated pitting
(v)
Widespread pitting
Vessel Skirts/Supports:
a) Skirt mechanically sound
b) Skirt coating good
c) Skirt clean inside
d) Fireproofing in good condition
e) Skirt drain is clean (no debris)
f) Support sliding pad good condition
g) Saddle shoe aligned with the supports
h)

Support guides available and mechanically sound

i)

Welds on structural support(s) in good condition

2
j) Pipe support base /I beam in good condition (no
gap)
k) Structural component(s) in good condition
l) Space between the saddle base and the support
beam clean ( no rust scales)

Yes

m) Dummy leg supports in good condition


n) Base plate(s) in good condition
o) Fireproofing in good condition
Nozzles/Manways/Flanges:
a) Nozzle and flanges in good condition
b) Special leak protection cover (caustic/chemical) in
good condition

c)

Flange coating in good condition (no corrosion)

d)

Flanges mechanically sound (no signs damage)

e) Stud bolts tight


f) Stud bolts of proper length
g) Jack screws available and serviceable
h) Bolts and nuts in good condition
i)

Weep holes of reinforcing pad properly greased

Drain/Vent/Blinds/Lifting Lugs:
a) Drain/vent plug available
b) Nipples/root valve properly seal welded
c) Reinforcing pads in good condition (no signs of
leaks on weep holes)
d) Welds on reinforcing pads in good condition
e) Drain valve blinded at end
f) Spectacle blind installed for positive isolation
g) Drain/vent nipple or other fittings in good
condition
h) Davits/lifting lugs fully operational
i) Dead legs not present or removed
Isolation Valves:
a) Proper rating
b) Gland in good condition
c) Gland stud/eye bolt in good condition
d) Hand wheel available and mechanically sound
e) Valve body in good condition
f) Horizontal valve position indicator with safety
caution
Hot/Cold Insulation:
a) Metal jackets and insulation good condition
b) Aluminum cladding, vapor barrier, sealant and
insulation in good condition
c) Correct insulation material/sufficient thickness
d) All insulation straps available and fully tight
e) Insulation at OSI points covered
Miscellaneous Items:
a) Instrumentation:
(i)
Pressure gage(s) in good condition
(ii) Temperature gage(s) in good condition
(iii) Tags for gages available
(iv) Thermowells thread properly engaged

b)
7

INSPECTED BY
PIRECO-EPC CONTRACTOR
VENDOR-(NAME)
SOC-PROJECT

SOC-PR0CESS
SOC -OPERAION

c)

(v) Thermal relief valve(s) in good condition


(vi) Level sight glasses in good condition
Relief valves: (Use SAEP-319 Checklist)
(i)
Acceptable per SAEP 319 checklist
Connected piping:

(i)
Drain/vent /welding boss/RV piping in
good condition
(ii)
Piping flow direction arrow stenciled
(iii) Piping identification stenciled
(iv) Utility piping (steam etc.) has working
check valve
(v)
Corrosion monitoring Cosasco fitting
location marked
(vi) Piping adequately supported
(vii) Fluid flow smooth (no vibration)
NAME

DATE

RNAL INSPECTION CHECKLIST

DESCRIPTION

CHECKLIST
Tower-T 770

Inspection Date
Last Inspection
Date

No

N/A

REMARKS

NOT YET DONE

NOT YET DONE

DATE

SIGNATURE

RV Checklist for External Inspec


Department Name:
RV No.
(from SAP)

Plant No.:
Old RV

RV

No.

Location

PZV tag

(Equipment
No.)

No.

Set Pres.

CDTP

Plant/Unit No.: ______________

Test

Due

Bellow RV

Date

Date

Type
Painted Green

1
2
3
4
5
6
7
8
9
10
11
12

Block valve legend


O = Open, C = Close, A = Atmosphere

(Vertical stem is n
Checked By (Area Inspector): _______________________________

Inspection Field Supervisor: _______________________

Verified by (RV Coordinator): _______________________________

Corrective Action made by: _______________________

RV Checklist for External Inspection


Plant/Unit No.: ______________
Bellow RV

Upstream

Type

Downstream

Block Valve

Block Valve

Safe

Position

Car

Stem

Painted

Position

Car

Stem

Painted

Vent

O/C

Sealed

Position

Orange

O/C/A

Sealed

Position

Orange

Stem Position Legend


V = Vertical, H = Horizontal, SA = Sloping Away from valve
(Vertical stem is not to be allowed per SAES-J-600)

Field Supervisor: __________________________________

Action made by: _______________________Date: _____________

Remarks