Sie sind auf Seite 1von 147

18/02/2004

11:14

Page 1

www.GE-Security.com
GE Security reserves the right to change product specifications without notice.
For the latest product specifications, visit www.GE-Security.com or contact your Sales Representative.

03/2004

GE Security

Aritech Fire Systems Product Catalogue

CoverFireAritech.qxd

GE Security
Aritech
FIRE SYSTEMS
Product catalogue

In this catalogue you will find a wide range of


Fire Protection equipment from GE Security.
GE Security is a global technology leader dedicated
to supporting the needs of the rapidly growing
electronic security industry and to expanding
current technologies, products and services that

GE Security,
unrivalled expertise in
Fire Protection

create revenue growth opportunities for its


customers. As part of the GE family, GE Security
shares the spirit of innovation that has
distinguished GE for well over 100 years. GE
Security's commitment to the ongoing success of
its partners and affiliates means that we maintain
a sharp focus on product and service innovation,
world-class manufacturing practices and
operational excellence.
GE Security is a worldwide organisation with sales
and technical support operations in 27 countries,
and manufacturing and logistics operations in
Europe, the U.S. and China.
GE Security has expertise in all areas of electronic
security, including:
z

Intrusion and Fire Protection

Electronic Access and Facility Management

Key Management and Remote Access Systems


and Services

Fibre Optic Transmission and Reception


Equipment

CCTV, Digital Video and Surveillance Equipment

Video Multiplexing and Digital Storage

When you're looking for the finest in Fire


Protection products with leading-edge
technology and the backing of a world leader, you
need look no further than this catalogue.

CONVENTIONAL FIRE DETECTORS

300 SERIES

Conventional Fire Detectors


Page : 5

DI322I

Ionisation detector, conventional

The 300 Series conventional fire detectors are the ideal solution for any conventional
installation. They are built specifically for use with the Aritech FP400, FP500, FP600
and FP700 series conventional fire panels, but can also be connected to most 3rd
party industry standard conventional control panels.
Specifications

18 to 28 VDC

Operating voltage
Current consumption
Quiescent at 24 VDC

30 A

Alarm at 24 VDC

< 100 mA

Radio-active source
Average activity
Remote alarm output
Heat specification

Americium 241
0.33 +/-0.04Ci (12.1 +/- 1.5 kBq)
< 100 mA

Operating temperature
Storage temperature
Humidity (non-condensing)
IP rating
Number of detectors per zone
Recommended protection resistor
Dimensions (h x )

-10 to +60 C
-10 to +70 C
0 - 95%
IP205
20
300 ohm

Head

45 mm x 99 mm

Base

24 mm x 103 mm
VdS
LPCB

Approvals*
* Check current status with local office

Ordering Information
DI322I

Ionisation detector, conventional

Full line consisting of Optical, Ionisation and Heat


detectors
An ultra-fine grid prevents the ingress of dust and insects
in smoke detectors

Attractive, low-profile design

LPCB and VdS certification marks (*)

Innovative base compensates for uneven surfaces

Conventional Fire Detectors


Page : 6

DP331I

Optical detector, conventional, with field exchangeable optical block

The 300 Series conventional fire detectors are the ideal solution for any conventional
installation. They are built specifically for use with the Aritech FP400, FP500, FP600
and FP700 series conventional fire panels, but can also be connected to most 3rd
party industry standard conventional control panels.
Specifications

9 to 28 VDC

Operating voltage
Current consumption
Quiescent at 24 VDC

85 A

Alarm at 24 VDC

< 100 mA

Radio-active source
Average activity
Remote alarm output
Heat specification

< 100 mA

Operating temperature
Storage temperature
Humidity (non-condensing)
IP rating
Number of detectors per zone
Recommended protection resistor
Dimensions (h x )

-10 to +70 C
-10 to +70 C
0 - 95%
IP42
20
300 ohm

Full line consisting of Optical, Ionisation and Heat


detectors
An ultra-fine grid prevents the ingress of dust and insects
in smoke detectors

Head

45 mm x 99 mm

Base

24 mm x 103 mm

Attractive, low-profile design

EN54
*

LPCB and VdS certification marks (*)

Innovative base compensates for uneven surfaces

Approvals*
* Check current status with local office

Ordering Information
DP331I

Optical detector, conventional, with field exchangeable optical block

Conventional Fire Detectors


Page : 7

DT313I

Temperature detector (fixed and rate-of-rise), conventional

The 300 Series conventional fire detectors are the ideal solution for any conventional
installation. They are built specifically for use with the Aritech FP400, FP500, FP600
and FP700 series conventional fire panels, but can also be connected to most 3rd
party industry standard conventional control panels.
Specifications

18 to 28 VDC

Operating voltage
Current consumption
Quiescent at 24 VDC

70 A

Alarm at 24 VDC

< 100 mA

Radio-active source
Average activity
Remote alarm output
Heat specification
Operating temperature
Storage temperature
Humidity (non-condensing)
IP rating
Number of detectors per zone
Recommended protection resistor
Dimensions (h x )

< 100 mA
Max. & ROR to EN54p5
-10 to +70 C
-10 to +80 C
0 - 95%
IP205
20
300 ohm

Head

45 mm x 99 mm

Base

24 mm x 103 mm
VdS
LPCB

Approvals*
* Check current status with local office

Ordering Information
DT313I

Temperature detector (fixed and rate-of-rise), conventional

Full line consisting of Optical, Ionisation and Heat


detectors
An ultra-fine grid prevents the ingress of dust and insects
in smoke detectors

Attractive, low-profile design

LPCB and VdS certification marks (*)

Innovative base compensates for uneven surfaces

Conventional Fire Detectors


Page : 8

KCT731

KL731/DP331I Calibration Tool

The KCT731 is a calibration tool to recalibrate the KL731/DP331I conventional


detectors after replacement of the field exchangeable optical block.
Specifications

2 x 9 V batteries

Supply

Ordering Information
KCT731

KL731/DP331I Calibration Tool

Easy to use

Simple "go/no-go" function

Battery operated

Conventional Fire Detectors


Page : 9

DB304

Universal fire detector base (Aritech 300 and 1500 series)

The DB304 is a 4 contact universal detecor base for use with the Dx300 and Dx1500
series detectors from Aritech. It has the ability to compensate for uneven mounting
surfaces.
Specifications

Dimensions
Diameter

104 mm

Height

24 mm

Ordering Information
DB304

Universal fire detector base (Aritech 300 and 1500 series)

Polarity sensitive

Universal base fits conventional and analogue detectors

Compensates for uneven surfaces

Remote indicator contact available

EN54 approved

KZ705

Universal fire detector base with earth connection

The KZ705 is a 5 contact universal detector base for use with the KL700/Dx300 and
KL700A/Dx1500 series detectors from GE-Interlogix. In addition to the normal base
and remote indication connectors, the KZ705 also has an additional earth terminal
connector to allow for easy terminations of a possible cable screen.
Specifications

100 x 29 mm

Dimensions ( x h)
Operating Voltage
Current Consumption
Isolation Current
Isolation Resistance
Sounder Frequency
Sound Output
@ 3 mA
@ 5 mA
Environmental Characteristics
Operating Temperature

-10 to 70 C

Storage Temperature

-10 to 70 C

Relative Humidity (max)

95 % (non-cond.)

Ordering Information
KZ705

Universal fire detector base with earth connection

Polarity sensitive

Universal base fits conventional and analogue detectors

Additional earth terminal available

Remote indicator contact available

Conventional Fire Detectors


Page : 10

KZ705D

Conventional fire detector base with diode

The KZ705D is a 5 contact universal detector base for use with the KL700/Dx300
series detectors from GE-Interlogix. In addition to the normal base and remote
indication connectors, the KZ705D also has an additional earth terminal connector to
allow for easy terminations of a possible cable screen. The built in diode is
specifically targeted at systems using active end-of-line devices.
Specifications

100 x 29 mm

Dimensions ( x h)
Operating Voltage
Current Consumption
Isolation Current
Isolation Resistance
Sounder Frequency
Sound Output
@ 3 mA
@ 5 mA
Environmental Characteristics

Polarity sensitive

-10 to 70 C

Universal base for conventional detectors

95 % (non-cond.)

Additional earth terminal available

Remote indicator contact available

Built in diode for active end-of-line systems

Operating Temperature

-10 to 70 C

Storage Temperature
Relative Humidity (max)

Ordering Information
KZ705D

Conventional fire detector base with diode

Conventional Fire Detectors


Page : 11

EOL-ACT

Active end-of-line device for use with FP400/KL700 fire panels

The EOL-ACT is designed for use with the NK700/FP400 fire panels from GE-Interlogix.
It is an active end-of-line device to allow the monitoring of a conventional zone
through a diode base (such as the KZ705D).

Ordering Information
EOL-ACT

Active end-of-line device for use with FP400/KL700 fire panels

Small

Easy to install

KZ705R

Conventional fire detector base with relay

The KZ705R is a 5 contact detector base for use with the KL731/DP331I detectors
from GE-Interlogix. In addition to the normal base and remote indication connectors,
the KZ705R also has an additional earth terminal connector to allow for easy
terminations of a possible cable screen. A built in 12 V relay makes it ideal for use on
low voltage intrusion systems.
Specifications

100 x 29 mm
12 V 10%
12 A

Dimensions ( x h)
Operating Voltage
Current Consumption
Isolation Current
Isolation Resistance
Sounder Frequency
Sound Output
@ 3 mA
@ 5 mA

Polarity sensitive

12 V relay for 4 wire systems


Additional earth terminal available
Remote indicator contact available

Environmental Characteristics
Operating Temperature

-10 to 70 C

Storage Temperature

-10 to 70 C

Relative Humidity (max)

95 % (non-cond.)

Ordering Information
KZ705R

Conventional fire detector base with relay

Conventional Fire Detectors


Page : 12

S300

Surface mount supplement for KL300 detectors

The S300 is a base accessory designed for use with the KZ300 detector base. It
allows for a surface mount conduit and cable to enter the base from the side. The
KZ300 base fits on top of this accessory.
Specifications

Dimensions
Diameter

107 mm

Height

25 mm

Ordering Information
S300

Surface mount supplement for KL300 detectors

Surface mount accessory for KZ300

S700

Surface mount accessory for KZ700/DB304 and KZ700 series bases

The S700 is a base accessory designed for use with the KZ700 series detector bases.
It allows for a surface mount conduit and cable to enter the base from the side. The
KZ700 series base fits on top of this accessory.
Specifications

Dimensions
Diameter

95 mm

Height

30 mm

Ordering Information
S700

Surface mount accessory for KZ700/DB304 and KZ700 series bases

Surface mount accessory for KZ700 series bases

CONVENTIONAL FIRE DETECTORS

700 SERIES

Conventional Fire Detectors


Page : 15

DP721I

Photoelectric smoke detector with remote alarm LED output

700 series
The smoke detector continually monitors its own sensitivity and operational status.
Once a day, it performs a full diagnostic test which includes dynamically testing the
sensing chamber and internal electronics.
Specifications

8.5 - 33 V dc FWR

Operating voltage
Current consumption
Quiescent at 24 V dc

100 A; Max. 70 A average

In alarm at 24 V dc

60 mA
White LED (red alarm)
Yellow LED
30 mA
2 A @ 30 V dc;1 A @ 120 V ac
0 - 95%; Non-condensing
IP 43
10%/m (+1.6%, -3.3%)
2,5 V max
1 sec
10 cm , H = 5 cm

Alarm indication
Fault indication
Remote alarm output
RY contact rating
Humidity
IP rating
Sensitivity
Reset voltage
Reset time
Dimensions

Ordering Information
DP721I
DP721R
DB702

EN 54 approved

VDS certified

Photoelectric smoke detector with remote alarm LED output


Photoelectric smoke detector with C/O relay output
10 cm diameter base - 6 terminals

Photoelectric smoke and heat detector head with remote alarmLED output

700 series
Fitted with a field-exchangeable optical block. The smoke detector continually
monitors its own sensitivity and operational status. Once a day, it performs a full
diagnostic test which includes dynamically testing the sensing chamber and internal
electronics.
Specifications

8.5 - 33 V dc FWR

Operating voltage
Current consumption
Quiescent at 24 V dc

100 A; Max. 70 A average

In alarm at 24 V dc

60 mA
White LED (red alarm)
Yellow LED
30 mA
2 A @ 30 V dc;1 A @ 120 V ac
0 - 95%; Non-condensing
IP 43
10%/m (+1.6%, -3.3%)
2,5 V max
1 sec
10 cm , H = 5 cm

Alarm indication
Fault indication
Remote alarm output
RY contact rating
Humidity
IP rating
Sensitivity
Reset voltage
Reset time
Dimensions

Ordering Information
DP721T
DP721RT
DP721RTA
DB702

Photoelectric smoke and heat detector head with remote alarmL


Photoelectric smoke and heat detector with relay output
Photoelectric smoke and heat detector with relay output, autoreset
10 cm diameter base - 6 terminals

EN 54 approved

VDS certified

DP721T

Conventional Fire Detectors


Page : 16

DT713-5

57 C fixed and rate-of-rise heat detector

700 series
The smoke detector continually monitors its own sensitivity and operational status.
Once a day, it performs a full diagnostic test which includes dynamically testing the
sensing chamber and internal electronics.
Specifications

8.5 - 33 V dc FWR

Operating voltage
Current consumption
Quiescent at 24 V dc

100 A; Max. 70 A average

In alarm at 24 V dc

60 mA
Red LED
Yellow LED
30 mA
2 A @ 30 V dc;1 A @ 120 V ac
0 - 95%; Non-condensing
IP 43

Alarm indication
Fault indication
Remote alarm output
RY contact rating
Humidity
IP rating
Heat specification
Max.

57 C 1.5 C

R.O.R.

8 C/min and > 40 C

Sensitivity
2,5 V max
1 sec
10 cm , H = 5 cm

Reset voltage
Reset time
Dimensions

Ordering Information
DT713-5
DT713-5R
DB702

57 C fixed and rate-of-rise heat detector


57 C and R.O.R. heat detector, with relay output
10 cm diameter base - 6 terminals

EN 54 approved

VDS certified

Conventional Fire Detectors


Page : 17

DT713-7

70 C fixed and R.O.R. heat detector

700 series
The smoke detector continually monitors its own sensitivity and operational status.
Once a day, it performs a full diagnostic test which includes dynamically testing the
sensing chamber and internal electronics.
Specifications

8.5 - 33 V dc FWR

Operating voltage
Current consumption
Quiescent at 24 V dc

100 A; Max. 70 A average

In alarm at 24 V dc

60 mA
Red LED
Yellow LED
30 mA
2 A @ 30 V dc;1 A @ 120 V ac
0 - 95%; Non-condensing
IP 43

Alarm indication
Fault indication
Remote alarm output
RY contact rating
Humidity
IP rating
Heat specification
Max.

70 C 1.5 C

R.O.R.

8 C/min and > 40 C


2,5 V max
1 sec
10 cm , H = 5 cm

Reset voltage
Reset time
Dimensions

Ordering Information
DT713-7
DB702

70 C fixed and R.O.R. heat detector


10 cm diameter base - 6 terminals

EN 54 approved

VDS certified

Conventional Fire Detectors


Page : 18

DB702

10 cm diameter base - 6 terminals

700 series
Detector base for 700 series detectors

Ordering Information
DB702
DB702U

10 cm diameter base - 6 terminals


15 cm diameter base - 6 terminals

EN 54 approved

VDS certified

CONVENTIONAL FIRE DETECTORS

650 SERIES

Conventional Fire Detectors


Page : 21

DI650

Ionisation smoke detector

650 series
This elegant slim-line ionisation detector offers high performance and wide operating
voltage
Specifications

Size of detector (mm)


Height

42

Diameter

100

Size of detector + base (mm)


Height

50

Diameter

100

9 - 33 V dc
Supply voltage
28 A
Quiescent Current at 24 V (typical)
LED
Alarm indication
Normal operating temp. range (no icing) -20 to + 60C
0-95% RH
Humidity (no condensation)
10m/s
Max. wind
17 mA
Remote alarm output current
43
IP Rating

Ordering Information
DI650
DI651
DB860

Ionisation smoke detector


Integrating ionisation smoke dectector
Standard Base

Polarity insensitive

Common base

Elegant slim-line design

EN 54 approved

Wide operating voltage

Conventional Fire Detectors


Page : 22

DP652

Optical smoke detector

650 series
This elegant slim-line optical sensor provides high performance and wide operating
range.
Specifications

Size of detector (mm)


Height

42

Diameter

100

Size of detector + base (mm)


Height

50

Diameter

100

9 - 33 V dc
Supply voltage
40 A
Quiescent Current at 24 V (typical)
LED
Alarm indication
Normal operating temp. range (no icing) -20 to + 60C
0-95% RH
Humidity (no condensation)
Not affected
Max. wind
17 mA
Remote alarm output current
43
IP Rating

Ordering Information
DP652
DB860

Optical smoke detector


Standard Base

Polarity insensitive

Common base

Elegant slim-line design

EN 54 approved

Wide operating voltage

Conventional Fire Detectors


Page : 23

DT654

Heat detector, R.O.R., 57 C A1R

650 series
This elegant slim-line heat sensor has a wide operating temperature and is available
in four ranges
Specifications

Size of detector (mm)


Height

42

Diameter

100

Size of detector + base (mm)


Height

50

Diameter

100

9 - 33 V dc
Supply voltage
45 A
Quiescent Current at 24 V (typical)
LED
Alarm indication
Normal operating temp. range (no icing) -20 to + 60C
0-95% RH
Humidity (no condensation)
Not affected
Max. wind
17 mA
Remote alarm output current
54
IP Rating

Ordering Information
DT654
DT655
DT656
DT657
DB860

Heat detector, R.O.R., 57 C A1R


Heat detector, 75 C BR
Heat detector, 95 C CR
Heat detector, 90 C CS
Standard Base

Polarity insensitive

Common base

Elegant slim-line design

EN 54 approved

Wide operating voltage

Conventional Fire Detectors


Page : 24

DB860

Standard Base

650 series
The base has been designed to enable detectors to be plugged in without any need for
force - particularly useful when fitting to suspended ceilings.

Ordering Information
DB860

Standard Base

Polarity insensitive

Common base

Elegant slim-line design

EN 54 approved

DB861

Backplate for Ingress Protection 860-950

Ordering Information
DB861

Backplate for Ingress Protection 860-950

Can prevent most ingress into the base and detector

Conventional Fire Detectors


Page : 25

DB806

Conduit box for 860 / 950 series bases

An inexpensive and versatile accessory for surface mounting 860 and 950 series
bases

Ordering Information
DB806

Conduit box for 860 / 950 series bases

DB650

650 series relay base

650 series
The relay base provides a volt-free contact for use in 4 wire control systems, and
other applications

Ordering Information
DB650

650 series relay base

DB650

For use with 4 wire control systems

Automatic door closers

Volt-free relay contacts

ANALOGUE ADDRESSABLE DETECTORS

1500 SERIES

Analogue Adressable Fire Detectors


Page : 29

DI1552

Ionisation Sensor

The 1500 Series uses a microprocessor for measurement and communication. An


enhanced protocol ensures the overall
integrity and error free operation of the system, without compromising detection
speed. All sensors are compatible with a standard base that makes them easily
interchangeable and support the connection of a remote indicator.
Specifications

22 to 38 VDC

Operating voltage
Current consumption
Quiescent @ 38 VDC

200 A

In Alarm

< 11 mA

Alarm indication (Dual LED)


Remote Alarm Output
Environment

White OFF - Red ON


Available

Storage Temperature

-10 to +70 C

Operating Temperature

-10 to +60 C

Humidity (non-condensing)

0-95%

IP rating

IP42
0.33 0.04 Ci Am 241
45 x 99 mm

Radioactive Source
Dimensions (h x )

Ordering Information
DI1552

Ionisation Sensor

Remote signalling capabilities

Optical sensor with field exchangeable optical chamber

Easy soft addressing (1-125)

SMD technology

Reliable communication protocol

Full diagnostic self testing

Full range: Ionisation, Optical and Heat and Dual sensors


(optical/heat)

Full range of supporting I/O units and accessories

EN54 Approved

Analogue Adressable Fire Detectors


Page : 30

DP1561

Optical Sensor with field exchangeable optical block

The 1500 Series uses a microprocessor for measurement and communication. An


enhanced protocol ensures the overall integrity and error free operation of the system,
without compromising detection speed. All sensors are compatible with a standard
base that makes them easily interchangeable and support the connection of aremote
indicator.
Specifications

22 to 38 VDC

Operating voltage
Current consumption
Quiescent @ 38 VDC

350 A

In Alarm

< 11 mA

Alarm indication (Dual LED)


Remote Alarm Output
Environment

Red
Available

Storage Temperature

-10 to +70 C

Operating Temperature

-10 to +60 C

Humidity (non-condensing)

0-95%

IP rating

IP42
NA
45 x 99 mm

Radioactive Source
Dimensions (h x )

Ordering Information
DP1561

Optical Sensor with field exchangeable optical block

Remote signalling capabilities

Optical sensor with field exchangeable optical chamber

Easy soft addressing (1-125)

SMD technology

Reliable communication protocol

Full diagnostic self testing

Full range: Ionisation, Optical and Heat and Dual sensors


(optical/heat)

Full range of supporting I/O units and accessories

EN54 Approved

Analogue Adressable Fire Detectors


Page : 31

DP1551T

Dual Sensor (Optical/Heat)

The 1500 Series uses a microprocessor for measurement and communication. An


enhanced protocol ensures the overall integrity and error free operation of the system,
without compromising detection speed. All sensors are compatible with a standard
base that makes them easily interchangeable and support the connection of aremote
indicator.
Specifications

22 to 38 VDC

Operating voltage
Current consumption
Quiescent @ 38 VDC

350 A

In Alarm

< 5 mA

Alarm indication (Dual LED)


Remote Alarm Output
Environment

Red
Available

Storage Temperature

-10 to +70 C

Operating Temperature

-10 to +70 C

Humidity (non-condensing)

0-95%

IP rating

IP42
NA
51 x 99 mm

Radioactive Source
Dimensions (h x )

Ordering Information
DP1551T

Dual Sensor (Optical/Heat)

Remote signalling capabilities

Optical sensor with field exchangeable optical chamber

Easy soft addressing (1-125)

SMD technology

Reliable communication protocol

Full diagnostic self testing

Full range: Ionisation, Optical and Heat and Dual sensors


(optical/heat)

Full range of supporting I/O units and accessories

EN54 Approved

Analogue Adressable Fire Detectors


Page : 32

DT1553

Heat Sensor

The 1500 Series uses a microprocessor for measurement and communication. An


enhanced protocol ensures the overall integrity and error free operation of the system,
without compromising detection speed. All sensors are compatible with a standard
base that makes them easily interchangeable and support the connection of aremote
indicator.
Specifications

22 to 38 VDC

Operating voltage
Current consumption
Quiescent @ 38 VDC

250 A

In Alarm

< 11 mA

Alarm indication (Dual LED)


Remote Alarm Output
Environment

White OFF - Red ON


Available

Storage Temperature

-10 to +80 C

Operating Temperature

-10 to +70 C

Humidity (non-condensing)

0-95%

IP rating

IP42
NA
45 x 99 mm

Radioactive Source
Dimensions (h x )

Ordering Information
DT1553

Heat Sensor

Remote signalling capabilities

Optical sensor with field exchangeable optical chamber

Easy soft addressing (1-125)

SMD technology

Reliable communication protocol

Full diagnostic self testing

Full range: Ionisation, Optical and Heat and Dual sensors


(optical/heat)

Full range of supporting I/O units and accessories

EN54 Approved

Analogue Adressable Fire Detectors


Page : 33

PG700

Fire sensor programmer

The PG700 is a handheld device programmer and tester for the KL700A/Dx1500 series
detectors. It is battery operated and allows the installer to perform installation tasks
(such as device addressing) and maintenance tasks (such as device clibration) in the
field without external assistance.
Specifications

2 x 9 V batteries

Supply

Ordering Information
PG700

Fire sensor programmer

Easy to use

Battery operated

4 User selectable programs

- Device analogue value

- Change Device Address

- Sequential device addressing

- KL731A Calibration

Analogue Adressable Fire Detectors


Page : 34

KZ705I

Analogue fire detector base with isolator

The KZ705I is a detector base with built in isolator for use with the KL700A/Dx1500
series detectors from GE-Interlogix. The isolator protects the loop from short circuit
conditions. A LED on the side of the base indicates the status of the isolator.
Specifications

100 x 29 mm
17 - 34 V
50 A
6 mA
140 MOhm

Dimensions ( x h)
Operating Voltage
Current Consumption
Isolation Current
Isolation Resistance
Sounder Frequency
Sound Output
@ 3 mA
@ 5 mA
Environmental Characteristics
Operating Temperature

-10 to 70 C

Storage Temperature

-10 to 70 C

Relative Humidity (max)

95 % (non-cond.)

Ordering Information
KZ705I

Analogue fire detector base with isolator

Polarity sensitive

Universal base for analogue detectors

Additional earth terminal available

Remote indicator contact available

Built in isolator

Analogue Adressable Fire Detectors


Page : 35

KZ705AS

Analogue fire detector base with sounder

The KZ705AS is a detector base with built in analogue addressable sounder for use
with the KL700A/Dx1500 series detectors from GE-Interlogix. The sounder has its own
address on the fire panel loop and works independent of the detector. It is fully
controlled from the fire panel.
Specifications

120 x 58 mm
22 - 38 V
300 A Quiescent

Dimensions ( x h)
Operating Voltage
Current Consumption
Isolation Current
Isolation Resistance

1 KHz

Sounder Frequency
Sound Output
@ 3 mA

85 dBA

@ 5 mA

95 dBA

Environmental Characteristics
Operating Temperature

-10 to 70 C

Storage Temperature

-10 to 70 C

Relative Humidity (max)

95 % (non-cond.)

IP Rating

IP21c

Ordering Information
KZ705AS

Polarity sensitive

Universal base for analogue detectors

Additional earth terminal available

Remote indicator contact available

Built in sounder

Up to 90 dBA sound output

Low current consumption

Analogue fire detector base with sounder

Analogue Adressable Fire Detectors


Page : 36

KZ705IAS

Analogue fire detector base with isolator and sounder

The KZ705IAS is a detector base with built in analogue addressable sounder and
isolator for use with the KL700A/Dx1500 series detectors from GE-Interlogix. The
sounder has its own address on the fire panel loop and works independent of the
detector. It is fully controlled from the fire panel. The isolator protects the loop from
short circuit conditions.
Specifications

120 x 58 mm
22 - 38 V
350 A Quiescent
6 mA
140 MOhm
1 KHz

Dimensions ( x h)
Operating Voltage
Current Consumption
Isolation Current
Isolation Resistance
Sounder Frequency
Sound Output
@ 3 mA

85 dBA

@ 5 mA

95 dBA

Environmental Characteristics
Operating Temperature

-10 to 70 C

Storage Temperature

-10 to 70 C

Relative Humidity (max)


IP Rating

Polarity sensitive

95 % (non-cond.)

Universal base for analogue detectors

IP21c

Additional earth terminal available

Remote indicator contact available

Built in sounder

Up to 90 dBA sound output

Low current consumption

Built in isolator

Ordering Information
KZ705IAS

Analogue fire detector base with isolator and sounder

Analogue Adressable Fire Detectors


Page : 37

KAL410

Conventional Zone Monitor Unit - 1 Zone

Allows the connection of one conventional zone to the analogue fire system loop. This
zone is constantly monitored. Up to 20 conventional devices may be connected to this
zone.
Specifications

22-38 VDC

Supply voltage
Current consumption
Quiescent @ 24 V

90 A

Quiescent @ 35 V

105 A

Alarm

< 3 mA

Aux. Supply (24V DC) Quiescent

200 A + equip

Aux. Supply (24V DC) Alarm

< 85 mA
4.7 kOhm
NA

End-of-line resistor
Relay contact rating
Environmental
Storage temperature

-10 to +50C

Operating temperature

-10 to +70C

Relative humidity (non-condensing) 0-95 %

Ordering Information
KAL410

Easy numeric addressing

Continuous supervision of the conventional zones

Surface mount

Local alarm indication

Externally powered

Aesthetically pleasing

Part of a family of I/O modules consisting of:

117 x 80 x 44 mm

Dimensions (l x w x h)

Conventional Zone Monitor Unit - 1 Zone

- Conventional Zone Monitors

- Digital Input Modules

- Extinguishing Control Modules

- Isolator Modules

- Manual Call Points

- Output Units

- Retention Units

- Supervised Output Units for sounder control

Analogue Adressable Fire Detectors


Page : 38

KAL414/4

Conventional Zone Monitor Unit - 4 Zones

Allows the connection of four conventional zones to the analogue fire system loop.
These zones are constantly monitored. Up to 20 conventional devices may be
connected to any zone.
Specifications

22-38 VDC

Supply voltage
Current consumption
Quiescent @ 24 V

110 A

Quiescent @ 35 V

135 A

Alarm

< 5 mA

Aux. Supply (24V DC) Quiescent

200 A + equip

Aux. Supply (24V DC) Alarm

< 360 mA
4.7 kOhm
NA

End-of-line resistor
Relay contact rating
Environmental
Storage temperature

-10 to +50C

Operating temperature

-10 to +70C

Relative humidity (non-condensing) 0-95 %

Ordering Information
KAL414/4

Easy numeric addressing

Continuous supervision of the conventional zones

Surface mount

Local alarm indication

Externally powered

Aesthetically pleasing

Part of a family of I/O modules consisting of:

163 x 107 x 36 mm

Dimensions (l x w x h)

Conventional Zone Monitor Unit - 4 Zones

- Conventional Zone Monitors

- Digital Input Modules

- Extinguishing Control Modules

- Isolator Modules

- Manual Call Points

- Output Units

- Retention Units

- Supervised Output Units for sounder control

Analogue Adressable Fire Detectors


Page : 39

KAL426

Extinguishing Control Module

The 400 Series modules consists of a complete range of interfaces developed for
input/output control in the KSA700/FP1500 analogue fire systems from GE Interlogix.
The KAL426 allows for the connection and control of one extinguishing area to the
addressable fire panel loop.
Specifications

22-38 VDC

Supply voltage
Current consumption
Quiescent @ 24 V

110 A

Quiescent @ 35 V

210 A

Alarm

< 10 mA

Aux. Supply (24V DC) Quiescent

120 mA

Aux. Supply (24V DC) Alarm

<1A
4.7 kOhm
2 A

End-of-line resistor
Relay contact rating
Environmental
Storage temperature

-10 to +50C

Operating temperature

-10 to +70C

Aesthetically pleasing

Easy numeric addressing

Externally powered

Supervised I/O

Surface mount

Part of a range of I/O modules consiting of:

Relative humidity (non-condensing) 0-95 %


163 x 107 x 36 mm

Dimensions (l x w x h)

Ordering Information
KAL426

Extinguishing Control Module

PK10TD-ING
PK10TP-ING

Extinguishing RELEASE MCP with protective cover (English Version)


Extinguishing INHIBIT MCP with protective cover (English Version)

KR24B

Illuminated warning sign (No text) 24VDC

SK07

Low consumption multi-tone alarm siren

PK10CD
PK10CP

Spare glass for extinguishing RELEASE call point


Spare glass for extinguishing INHIBIT call point

- Conventional Zone Monitors

- Digital Input Modules

- Isolator Modules

- Manual Call Points

- Output Units

- Retention Units

- Supervised Output Units for sounder control

Analogue Adressable Fire Detectors


Page : 40

KAL430

Relay Module - 1 Relay

Provides for one potential free relay output for the fire system loop. Each relay allows
for COMMON, NORMALLY OPEN and NORMALLY CLOSED contacts. The output may be
used to activate ventilation controls, warning signs, activation of other alarm devices
etc. during fire situations.
Specifications

22-38 VDC

Supply voltage
Current consumption
Quiescent @ 24 V

70 A

Quiescent @ 35 V

100 A

Alarm

< 3.5 mA

Aux. Supply (24V DC) Quiescent

22 mA

Aux. Supply (24V DC) Alarm

< 50 mA
NA
2A @ 250 VAC

End-of-line resistor
Relay contact rating
Environmental
Storage temperature

-10 to +50C

Operating temperature

-10 to +70C

Easy numeric addressing

Externally powered

Normally open / normally closed operation for I/O

Surface mount

Aesthetically pleasing

Local status indication

Part of a family of I/O modules consiting of:

Relative humidity (non-condensing) 0-95 %


117 x 80 x 44 mm

Dimensions (l x w x h)

Ordering Information
KAL430

Relay Module - 1 Relay

- Conventional Zone Monitors

- Digital Input Modules

- Extinguishing Control Modules

- Isolator Modules

- Manual Call Points

- Output Units

- Retention Units

- Supervised Output Units for sounder control

Analogue Adressable Fire Detectors


Page : 41

KAL434/4

Relay Module - 4 Relays

Provides for four potential free relay outputs for the fire system loop. Each relay
allows for COMMON, NORMALLY OPEN and NORMALLY CLOSED contacts. The outputs
may be used to activate ventilation controls, warning signs, activation of other alarm
devices etc. during fire situations.
Specifications

22-38 VDC

Supply voltage
Current consumption
Quiescent @ 24 V

110 A

Quiescent @ 35 V

135 A

Alarm

10 mA

Aux. Supply (24V DC) Quiescent

100 A

Aux. Supply (24V DC) Alarm

10 mA
NA
2A @ 250 VAC

End-of-line resistor
Relay contact rating
Environmental
Storage temperature

-10 to +50C

Operating temperature

-10 to +70C

Easy numeric addressing

Externally powered

Normally open / normally closed operation for I/O

Surface mount

Aesthetically pleasing

Local status indication

Part of a family of I/O modules consiting of:

Relative humidity (non-condensing) 0-95 %


163 x 107 x 36 mm

Dimensions (l x w x h)

Ordering Information
KAL434/4

Relay Module - 4 Relays

- Conventional Zone Monitors

- Digital Input Modules

- Extinguishing Control Modules

- Isolator Modules

- Manual Call Points

- Output Units

- Retention Units

- Supervised Output Units for sounder control

Analogue Adressable Fire Detectors


Page : 42

KAL440

Supervised Relay Module

Allows for the supervision of a single, 24 Volt powered output contact on the fire
system loop. This unit may be used to control for e.g. sounders in case of fire
conditions, but may also be used to switch any output considered crucial enough to
have the cable integrity between the unit and the switch point monitored.
Specifications

22-38 VDC

Supply voltage
Current consumption
Quiescent @ 24 V

110 A

Quiescent @ 35 V

135 A

Alarm

< 3.6 mA

Aux. Supply (24V DC) Quiescent

23 mA

Aux. Supply (24V DC) Alarm

23 mA + equip
4.7 kOhm
1 A @ 250 VAC

End-of-line resistor
Relay contact rating
Environmental
Storage temperature

-10 to +50C

Operating temperature

-10 to +70C

Easy numeric addressing

Externally powered

Normally open / normally closed operation for I/O

Surface mount

Aesthetically pleasing

Local status indication

Part of a family of I/O modules consiting of:

Relative humidity (non-condensing) 0-95 %


117 x 80 x 44 mm

Dimensions (l x w x h)

Ordering Information
KAL440

Supervised Relay Module

- Conventional Zone Monitors

- Digital Input Modules

- Extinguishing Control Modules

- Isolator Modules

- Manual Call Points

- Output Units

- Retention Units

- Supervised Output Units for sounder control

Analogue Adressable Fire Detectors


Page : 43

KAL450

Addressable Manual Call Point

The 400 Series modules consists of a complete range of interfaces developed for
input/output control in the KSA700/FP1500 analogue fire systems from GE Interlogix.
The KAL450 is an addressable manual call point for manual fire activation.
Specifications

22-38 VDC

Supply voltage
Current consumption
Quiescent @ 24 V

90 A

Quiescent @ 35 V

120 A

Alarm

< 3.5 mA

Aux. Supply (24V DC) Quiescent

NA

Aux. Supply (24V DC) Alarm

NA
NA
NA

End-of-line resistor
Relay contact rating
Environmental
Storage temperature

-10 to +50C

Operating temperature

-10 to +70C

Relative humidity (non-condensing) 0-95 %

Ordering Information
KAL450

Easy numeric addressing

Loop powered

Local test facility

Surface or flush mount

Aesthetically pleasing

Local status indication

Part of a family of I/O modules consiting of:

87 x 87 x 20

Dimensions (l x w x h)

Addressable Manual Call Point

DM715
DM790
DM787
DM782

Glass, EN54, Universal


Flush mount cradle with connectors
Surface mounting box with connectors
Hinged transparent MCP protection cover

DM800

Resettable element for MCP DM700/KAL450

- Conventional Zone Monitors

- Digital Input Modules

- Extinguishing Control Modules

- Isolator Modules

- Manual Call Points

- Output Units

- Retention Units

- Supervised Output Units for sounder control

Analogue Adressable Fire Detectors


Page : 44

KAL460

Digital Input Module

Provides a remote input to the fire system loop. The input is constantly monitored and
its status communicated to the fire control panel. The input may be activated by
closing or opening a potential free contact, depending on the module configuration.
This module may be used to monitor any contact by showing its status through the
fire control panel e.g. the monitoring of pressure equipment and closure fire break
doors.
Specifications

22-38 VDC

Supply voltage
Current consumption
Quiescent @ 24 V

110 A

Quiescent @ 35 V

135 A

Alarm

< 10 mA

Aux. Supply (24V DC) Quiescent

200 A

Aux. Supply (24V DC) Alarm

< 50 mA
NA
NA

End-of-line resistor
Relay contact rating
Environmental
Storage temperature

-10 to +50C

Operating temperature

-10 to +70C

Relative humidity (non-condensing) 0-95 %


117 x 80 x 44 mm

Dimensions (l x w x h)

Ordering Information
KAL460

Digital Input Module

Easy numeric addressing

Externally powered

Normally open / normally closed operation for I/O

Surface mount

Aesthetically pleasing

Local status indication

Part of a family of I/O modules consiting of:

- Conventional Zone Monitors

- Digital Input Modules

- Extinguishing Control Modules

- Isolator Modules

- Manual Call Points

- Output Units

- Retention Units

- Supervised Output Units for sounder control

Analogue Adressable Fire Detectors


Page : 45

KAL470

Isolator Module

The 400 series modules consist of a complete range of interfaces developed for
input/output control in the KSA700/FP1500 analogue fire systems from GE Interlogix.
The KAL470 is an isolator module in this series that isolates the faulty zone on a fire
panel loop during short circuit conditions. The KAL470 does not use an address on the
loop.
Specifications

22-38 VDC

Supply voltage
Current consumption
Quiescent @ 24 V

110 A

Quiescent @ 35 V

135 A

Alarm

10 mA

Aux. Supply (24V DC) Quiescent

NA

Aux. Supply (24V DC) Alarm

NA
NA
NA

End-of-line resistor
Relay contact rating
Environmental
Storage temperature

-10 to +50C

Operating temperature

-10 to +50C

Relative humidity (non-condensing) 0-95 %


75 x 45 x 28 mm

Dimensions (l x w x h)

Requires no device address

Automatic reset

Local status indication

Surface mount

Part of a family of I/O modules consiting of:

Ordering Information
KAL470

Isolator Module

- Conventional Zone Monitors

- Digital Input Modules

- Extinguishing Control Modules

- Manual Call Points

- Output Units

- Retention Units

- Supervised Output Units for sounder control

Analogue Adressable Fire Detectors


Page : 46

KAL490

Retention Module - 1 Input / 1 Output

Provides a remote input and a potential free voltage relay output to the fire system
loop. The input signal is constantly monitored and its status displayed on the control
panel, whilst the output is fail-to-safe. Auxiliary supply monitoring is also included.
The module is used to for e.g. control and monitor doors such as fire break doors. The
relay provides the door activation and the input monitors the door status.
Specifications

22-38 VDC

Supply voltage
Current consumption
Quiescent @ 24 V

110 A

Quiescent @ 35 V

135 A

Alarm

10 mA

Aux. Supply (24V DC) Quiescent

200 A

Aux. Supply (24V DC) Alarm

< 50 mA
NA
1A @ 30 VAC/VDC

End-of-line resistor
Relay contact rating
Environmental
Storage temperature

-10 to +50C

Operating temperature

-10 to +70C

Relative humidity (non-condensing) 0-95 %


117 x 80 x 44 mm

Dimensions (l x w x h)

Ordering Information
KAL490

Retention Module - 1 Input / 1 Output

Easy numeric addressing

Externally powered

Normally open / normally closed operation for I/O

Surface mount

Aesthetically pleasing

Local status indication

Part of a family of I/O modules consiting of:

- Conventional Zone Monitors

- Digital Input Modules

- Extinguishing Control Modules

- Isolator Modules

- Manual Call Points

- Output Units

- Retention Units

- Supervised Output Units for sounder control

ANALOGUE ADDRESSABLE DETECTORS

2000 SERIES

Analogue Adressable Fire Detectors


Page : 49

DP2051

Optical Sensor

2000 Series
Equipped with a field-exchangeable optical block and has full certification, this
optical sensor provides good looks as well as top features
Specifications

Operating Voltage
Current consumption at 24 V dc

17 - 28 V dc

Quiescent

< 150 A

Alarm

LED: 2 mA - 7-segment: 2 mA
White LED (red alarm)
Not provided
0 - 95% non condensing
IP43
-

Alarm indication
Remote alarm output
Max. wind
Humidity
IP rating
Source
Dimensions
Height

5 cm

Diameter

10 cm

Ordering Information
DP2051
DB2001
DB2016

Optical Sensor
Standard Base 10 cm, 2 Terminals
Isolating base

Remote test capabilities

Remote signalling capabilities

Optical sensor with field exchangeable optical chamber

Easy numeric addressing (1-128)

Enhanced communication protocol

Full diagnostic self testing

Polarity insensitive

Full range: optical and heat

Full range of I/0 units and accessories

Isolator base

EN54 approved

VdS approved

Analogue Adressable Fire Detectors


Page : 50

DP2061

Optical Sensor with remote LED output

2000 Series
Equipped with a field-exchangeable optical block and has full certification, this
optical sensor provides good looks as well as alarm and fault LEDs and remote output
Specifications

Operating voltage
Current consumption at 24 V dc

17 - 28 V dc

Quiescent

< 150 A

Alarm

LED: 2 mA - 7-segment: 2mA


4 mA
0 - 95% non condensing
IP43
-

Remote alarm output


Max. wind
Humidity
IP rating
Source
Dimensions
Height

5 cm

Diameter

10 cm

Ordering Information
DP2061
DB2002
DB2002U
DB2016

Optical Sensor with remote LED output


Standard Base 4 Terminals
Standard Base 15 cm, 4 Terminals
Isolating base

Remote test capabilities

Remote signalling capabilities

Optical sensor with field exchangeable optical chamber

Easy numeric addressing (1-128)

Enhanced communication protocol

Full diagnostic self testing

Polarity insensitive

Full range: optical and heat

Full range of I/0 units and accessories

Isolator base

EN54 approved

VdS approved

Analogue Adressable Fire Detectors


Page : 51

DP2071

Optical Sensor with 7-segment display and remote LED output

2000 Series
Equipped with a field-exchangeable optical block and with full certification, this
optical sensor provides good looks as well as top features. Fitted with an exclusive
7-segment display, the sensor provides comprehensive information. In addition to
alarm signalling, information such as Fault, Pre-alarm, Maintenance Alarm (Clean
me), Disabled Sensor, Sensor in Test, Error (double address, wrong sensor type) and
Sensor Polled is provided.
Specifications

Operating voltage
Current consumption at 24 V dc

17 - 28 V dc

Quiescent

< 150 A

Alarm

LED: 2 mA - 7-segment: 2 mA
White LED (red alarm)
4 mA
0 - 95% non condensing
IP43
-

Alarm indication
Remote alarm output
Max. wind
Humidity
IP rating
Source
Dimensions
Height

5 cm

Diameter

10 cm

Ordering Information
DP2071
DB2002
DB2002U
DB2016

Optical Sensor with 7-segment display


Standard Base 4 Terminals
Standard Base 15 cm, 4 Terminals
Isolating base

7-segment display

Remote test capabilities

Remote signalling capabilities

Optical sensor with field exchangeable optical chamber

Easy numeric addressing (1-128)

Enhanced communication protocol

Full diagnostic self testing

Polarity insensitive

Full range: optical and heat

Full range of I/0 units and accessories

Analogue Adressable Fire Detectors


Page : 52

DT2053

Heat Sensor

2000 series
Fully certified, this heat sensor provides good looks as well as top features.
Specifications

Operating voltage
Current consumption at 24 V dc

17 - 28 V dc

Quiescent

< 150 A

Alarm

LED: 2 mA - 7-segment: 2 mA
Red LED
Not provided
0 - 95% non condensing
IP43
-

Alarm indication
Remote alarm output
Max. wind
Humidity
IP rating
Source
Dimensions
Height

5 cm

Diameter

10 cm

Ordering Information
l

DT2053
DB2001
DB2016

VDS approved

Heat Sensor
Standard Base 10 cm, 2 Terminals
Isolating base

DT2063

Heat Sensor with Remote LED Output

2000 Series
Fully certified, this heat sensor provides good looks as well as top features. Dual
LED's indicate both alarm and fault. A remote output is also provided.
Specifications

Operating voltage
Current consumption at 24 V dc

17 - 28 V dc

Quiescent

< 150 A

Alarm

LED: 2 mA - 7-segment: 2 mA
Red LED
4 mA
0 - 95% non condensing
IP43
-

Alarm indication
Remote alarm output
Max. wind
Humidity
IP rating
Source
Dimensions
Height

5 cm

Diameter

10 cm

Ordering Information
DT2063
DB2002
DB2002U
DB2016

Heat Sensor with Remote LED Output


Standard Base 4 Terminals
Standard Base 15 cm, 4 Terminals
Isolating base

VDS approved

Analogue Adressable Fire Detectors


Page : 53

DT2073

Heat Sensor with 7-segment Display and Remote LED Output

2000 Series
Fitted with an exclusive 7-segment display, this detector provides comprehensive, on
the spot information. In addition to alarm signalling, information such as Fault,
Pre-alarm, Maintenance Alarm (Clean me), Disabled Sensor, Sensor in Test, Error
(double address, wrong sensor type) and Sensor Polled is provided.
Specifications

Operating voltage
Current consumption at 24 V dc

17 - 28 V dc

Quiescent

< 150 A

Alarm

LED: 2 mA - 7-segment: 2 mA
Red LED
4 mA
0 - 95% non condensing
IP43
-

Alarm indication
Remote alarm output
Max. wind
Humidity
IP rating
Source
Dimensions
Height

5 cm

Diameter

10 cm

Ordering Information
DT2073
DB2002
DB2002U
DB2016

Heat Sensor with 7-segment Display and Remote LED Output


Standard Base 4 Terminals
Standard Base 15 cm, 4 Terminals
Isolating base

VDS approved

Analogue Adressable Fire Detectors


Page : 54

DB2001

Standard Base 10 cm, 2 Terminals

2000 series
2 terminal base for DP2051 and DT2053

Ordering Information
DB2001

Standard Base 10 cm, 2 Terminals

VDS approved

DB2002

Standard Base 4 Terminals

2000 series
A four terminal base for all 2000 series detectors

Ordering Information
DB2002
DB2002U

Standard Base 4 Terminals


Standard Base 15 cm, 4 Terminals

VDS approved

Analogue Adressable Fire Detectors


Page : 55

DB2016

Isolating base

2000 series
The DB2016 isolator base senses and isolates short circuit faults. A yellow LED
indicates a short circuit condition. The detector in the base will still receive power in
the event of a single short circuit. If every detector is fitted with an isolator base
then no device will be lost in the event of a single short circuit.

Ordering Information
DB2016

Isolating base

VDS approved

IU2016

Loop Isolator

2000 series
The Aritech Loop Isolator is designed to prevent an entire communication loop from
being disabled in the event of a short circuit. The IU 2016 isolates that part of the
loop containing the short from the remainder of the circuit.
Specifications

17 - 28 V, comm. loop terminals


< 250 A

Operating voltage
Total standby current
Isolated current
Average

< 1.6 mA

Transition pulse

< 36 mA (5 ms duration)

Operating temperature
Operating humidity range
Line resistance

-10 C to 70 C
0 - 95%; Non-condensing

Normal

0.55 Ohms

Isolated

> 33K Ohms

Switching voltage
Normal to isolated

13.8 V dc

Isolated to normal

2.5 V dc

Switching time
Normal to isolated

< 5 ms

Isolated to normal

< 0.5 ms (after fault correction)

Ordering Information
IU2016
DB2003

Loop Isolator
Base for the IU2016 isolator

Complete isolation of loop short circuit

Automatic restore when fault is corrected

Module LED indicates location of fault

Analogue Adressable Fire Detectors


Page : 56

Base for the IU2016 isolator

Ordering Information
DB2003

Base for the IU2016 isolator

DB2003

Analogue Adressable Fire Detectors


Page : 57

DM2000

Manual call point, flying leads

2000 series
The DM 2000 is a break glass design call point with a high strength plastic housing.
The LED indicator provides visual confirmation of alarm initiation. The test key
(included with each unit) facilitates functional testing of the call point.
Specifications

17 - 28 V, @ comm.loop terminals
4 - 9 V dc
< 250 A
2.5 mA maximum
-10 C to 70 C
0 - 95%; Non-condensing

Operating voltage
Voltage modulation
Standby current
LED indicator current
Operating temperature
Operating humidity
Dimensions (L x W x H)
Flush mount

87 x 87 x 24 mm

Surface mount

87 x 87 x 56 mm

Ordering Information
DM2000
DM2000Y
DM2000B
DM711
DM715

Manual call point, flying leads


Manual call point flying leads - Yellow
Manual call point flying leads - Blue
Glass, EN54, Aritech
Glass, EN54, Universal

Analogue addressable manual call point

LED alarm indicator

Tamper resistant break glass design

Easy to test with self reset

Fast response

IP67 waterproof model available

Analogue Adressable Fire Detectors


Page : 58

DM2000E

Manual call point - Red IP67 waterproof, including backbox

2000 series
The DM 2000E is a break glass design call point with a high strength plastic housing
and IP67 waterproof. The LED indicator provides visual confirmation of alarm
initiation. The test key (included with each unit) facilitates functional testing of the
call point.
Specifications

17 - 28 V, @ comm.loop terminals
4 - 9 V dc
< 250 A
2.5 mA maximum
-10 C to 70 C
0 - 95%; Non-condensing

Operating voltage
Voltage modulation
Standby current
LED indicator current
Operating temperature
Operating humidity
Dimensions (L x W x H)
Flush mount

87 x 87 x 24 mm

Surface mount

87 x 87 x 56 mm

Ordering Information
DM2000E
DM711
DM715

Manual call point - Red IP67 waterproof, including backbox


Glass, EN54, Aritech
Glass, EN54, Universal

Analogue addressable manual call point

LED alarm indicator

Tamper resistant break glass design

Easy to test with self reset

Fast response

IP67 waterproof model available

Analogue Adressable Fire Detectors


Page : 59

IO2014

Input Output unit

2000 series IO
The Aritech range of loop powered Input/Output Modules are designed to provide
unlimited applications to input monitoring and output switching in 2000 Series
Analogue Addressable Fire Detection Systems.
The 2000 Series of I/O Modules combined with the powerful features of the FP 2000
Fire Panels gives the user total versatility.
Specifications

Operating voltage
Total standby current
Typical standby current
Operating temperature
Operating humidity range
Outputs
Inputs
100 K resistor in series with switch

No resistor in series with switch

EOL resistor

17 - 28 V
< 250 A
< 200 A
-10C to 70C
0 - 95%; Non-condensing
2 A max. at 30 V dc
States
Quiescent (switch open)
Switch closed
Open circuit
Short circuit
Quiescent (switch open)
Not valid
Open circuit
Switch closed
150 K, 1/4W, 5%

Ordering Information
IO2014
IO2031
IO2032
IO2034

Input Output unit


2 input/1 output
2 input/2 output
4 input/4 output

Wide range of I/O Modules : 2 input / 1 output, 2 input / 2


output, 4 input, 4 input / 4 output

Versatile input structure

Supervised inputs

Normally Open/Normally Closed operation

Magnetic latched output relays

Loop powered

No external power required

Easy numeric addressing

Analogue Adressable Fire Detectors


Page : 60

IU2050

Single Input Module

2000 series
The Aritech Analogue Addressable Single Input Module is designed for use with the FP
2000 Fire Panel to monitor normally open or normally closed
contacts. It can typically be connected to conventional Manual Call Points, Pull
Stations or Door Monitors and will report actuation within 1 second
depending on the programming of the fire panel.
Specifications

17 - 28 V, @ comm. loop terminals


4-9 V dc
< 250 A
-20 C to 70 C
0 - 95%; Non-condensing
150 K, 1/4 W, 5%

Operating voltage
Voltage modulation
Standby current
Operating temperature
Operating humidity
EOL resistor

Ordering Information
IU2050

Single Input Module


l

Analogue Addressable Single Input Module

Loop Powered

Supervised Input

Analogue Adressable Fire Detectors


Page : 61

IU2055

Conventional Zone Monitor

2000 series
The IU 2055 two-wire zone monitor is designed to provide an interface between
conventional smoke detectors and the analogue addressable FP 2000 fire panel. The
IU 2055 enables the FP 2000 panel to monitor the presence and operation of up to 30
detectors
Specifications

Operating voltage
Total standby current
Maximum alarm current
Maximum zone load current
Maximum zone capacitance
Maximum zone line length
Operating temperature
Operating humidity range
End of line resistor value
Zone impedances @ 24 V

17 - 39 V, @ comm. loop terminals


14 - 18.5 V, @ zone output terminals
< 15 mA
<35 mA @ comm. loop
3.5 mA, approx. 30 detectors
< 1F
< 100 ohm
-10 C to 70 C
0 - 95%; Non-condensing
3.9 k ohm

Short circuit

<100 Ohms

Fire

240 - 620 Ohms

Quiescent

2.7 K - 4.2 K Ohms

Open

> 15 K

Ordering Information
IU2055

Monitors up to 30 conventional smoke detectors

Zone circuit supervised for open and short circuits

Supports alarm verification/reset functions

Loop powered

Easy numeric addressing

Conventional Zone Monitor

GBX2000

Galvanic barrier

2000 series
A Galvanic barrier used with IU2055 zone monitor unit in intrinsic safe applications

Ordering Information
GBX2000

Galvanic barrier

Approved with the IU2055 zone monitor unit

Intrinsic safe operation when correctly installed

Analogue Adressable Fire Detectors


Page : 62

IU2080

Indicating Circuit Controller

2000 series
The Aritech Indicating Circuit Controller is designed for efficient, addressable control
of sounders, bells and strobes in a fire detection system. The 3 A of output power
available from the IU 2080 assures meeting all requirements for signaling devices on
a fire alarm system.
Specifications

Operating voltage
Total standby current
Maximum alarm current
Operating temperature
Operating humidity range
Circuit impedance at 24 V

17-28 V, at comm. loop terminals


<350 A, <200 A typical
<3.5 mA at comm. loop
-10 C to 70 C
0 - 95%; Non-condensing

Short circuit

<3.3 K

Quiescent

3.3 K - 13 K

Open circuit

<13 K

Power supply low voltage detection


Standby current
Alarm current
Supervisory voltage
Circuit voltage in alarm
Alarm current (fuse rating)
End of line resistor value

24 V; <20.4 V
<11 mA @ 24 V dc
<72 mA @ 24 V dc (plus output circuit load current from
ext. power supply)
2.2 V dc, inverted
24 V dc
3A
10 K, 1/4W, 5%

Ordering Information
IU2080

Indicating Circuit Controller

Versatile, addressable control for sounders, bells and


strobes

Supervised output circuit

Programmable output

24 V external power supply

Analogue Adressable Fire Detectors


Page : 63

2000 series addressable reflective beam smoke detector; 5 - 50m

2000 series
The FD 2705R and FD 2710R provides an integral, loop powered analogue
addressable reflective beam detector up to 100m distance. It operates with 2000
series protocol with the FP1200 / 2000 Fire panels
Specifications

10.2 - 30 V dc

Supply voltage
Range
FD 2705R:

5 - 50 meter

FD2710R:

50-100 meter
7.5 meter

Lateral detection
Current consumption:
quiescent

less than 4 ma

alarm

less than 25 ma
880 nm
-30C to 55 C
210 x 130 x 120 mm
IP50
Flame retardent ABS
Gray-black

Optical wave length


Operating temperature
Size
IP rating
Construction
Colour

Ordering Information
FD2705R
FD2710R

2000 series addressable reflective beam smoke detector; 5 - 50m


2000 series addressable reflective beam smoke detector; 50 - 100m

FD2705R

Analogue Adressable Fire Detectors


Page : 64

AS2015

2000 series loop powered sounder

2000 series
The AS2015 is a 2000 series addressable loop powered sounder for the FP1200 and
FP2000 range of fire panels. The unit has a built in isolator and can be synchronized.
Specifications

17-39 VDC

Operating voltage
Supply current
not activated

240A

activated

3mA

Sound output @ 1 meter


Continuous tone
Intermittent tone
Two tone

100 dB(A)
990 Hz
990 Hz, On Off @ 1 Hz
990 Hz / 650 Hz @ 1 Hz

Ordering Information
AS2015
AS2015W

2000 series loop powered sounder


2000 series loop powered sounder - white
l

Loop powered

Low current

Built in isolators

3 tones

FP1200 / 2000 fire panel operation

ANALOGUE ADDRESSABLE DETECTORS

950 SERIES

Analogue Adressable Fire Detectors


Page : 67

DI950

Analogue addressable ionisation sensor

950 series
This elegant slim-line ionisation sensor provides high-performance smoke detection
Specifications

17-28
Supply voltage (V dc)
280 A
Quiescent current
Red LED
Alarm indication
2 mA
Alarm LED current
Normal operating temperature (no icing) -20 to +60 C
0-95 %
Rel. humidity (no condensation)
10 m/s
Max. wind (continuous)
50 x 100
Size of device in base (H x mm)

Ordering Information
DI950

Analogue addressable ionisation sensor

Passive base address

Programmable slide-in address card

Aesthetic design

EN 54,BOSEC,VdS,CNBOP approved

DP951

Optical sensor

950 series
This elegant slim-line optical sensor provides high performance analogue
addressable features
Specifications

17-28
Supply voltage (V dc)
340 A
Quiescent current
Clear LED (red in alarm)
Alarm indication
4 mA
Alarm LED current
Normal operating temperature (no icing) -20 to +60 C
0-95 %
Rel. humidity (no condensation)
Not affected
Max. wind (continuous)
50 x 100
Size of device in base (H x mm)

Ordering Information
DP951
DB950

Optical sensor
950 series standard base

Passive base address

Programmable slide-in address card

Aesthetic design

EN 54,BOSEC,VdS,CNBOP approved

Analogue Adressable Fire Detectors


Page : 68

DT952

Analogue addressable temperature sensor

950 series
This elegant slim-line analogue addressable heat sensor provides exact temperature
information to the fire panel.
Specifications

17-28
Supply voltage (V dc)
250 A
Quiescent current
Red LED
Alarm indication
2 mA
Alarm LED current
Normal operating temperature (no icing) -20 to +60 C
0-95 %
Rel. humidity (no condensation)
Not affected in fixed temp. use
Max. wind (continuous)
50 x 100
Size of device in base (H x mm)

Ordering Information
DT952
DB950

Analogue addressable temperature sensor


950 series standard base

950 series analogue addressable manual callpoint

950 series
A manual call point operating with 950 series protocol.

Ordering Information
DM960

950 series analogue addressable manual callpoint

Passive base address

Programmable slide-in address card

Aesthetic design

EN 54,BOSEC,VdS,CNBOP approved

DM960

Analogue Adressable Fire Detectors


Page : 69

DI970

Intrinsic safe analogue addressable ionisation detector

970 series
An intrinsic safe ionisation detector, when used with the PT971/2 protocol simulator
and GBX70 barrier

Ordering Information
DI970
PT971
PT972
GBX70
DB970

Intrinsic safe analogue addressable ionisation detector


Intrinsic safe protocol translator
Dual channel IS protocol translator
Galvanic barrier (single channel)
Detector base for 970 series intrinsic safe sensors

Passive base address

Programmable slide-in address card

Aesthetic design

EN 54,BOSEC,VdS,CNBOP approved

DP971

Intrinsic safe optical detector

970 series
An intrinsic safe optical detector, when used with the PT971/2 protocol translator and
GBX70 barrier

Ordering Information
DP971
PT971
PT972
GBX70
DB970

Intrisic safe optical detector


Intrinsic safe protocol translator
Dual channel IS protocol translator
Galvanic barrier (single channel)
Detector base for 970 series intrinsic safe sensors

Passive base address

Programmable slide-in address card

Aesthetic design

EN 54,BOSEC,VdS,CNBOP approved

Analogue Adressable Fire Detectors


Page : 70

DT972

Intrinsic safe heat detector

970 series
An intrinsic safe heat detector, when used with the PT971/2 protocol translator and
GBX70 barrier

Ordering Information
DT972
PT971
PT972
GBX70
DB970

Intrinsic safe heat detector


Intrinsic safe protocol translator
Dual channel IS protocol translator
Galvanic barrier (single channel)
Detector base for 970 series intrinsic safe sensors

Intrinsic safe manual call point

970 series
An intrinsic safe manual call point, when used with the PT971/2 protocol translator
and GBX70 barrier.

Ordering Information
DM970

Intrinsic safe manual call point

Passive base address

Programmable slide-in address card

Aesthetic design

EN 54,BOSEC,VdS,CNBOP approved

DM970

Analogue Adressable Fire Detectors


Page : 71

Intrinsic safe protocol translator

PT971

970 series
A protocol translator for the 970 series analogue addressable intrinsic safe sensors.
This must be used with the GBX70 barrier

Ordering Information
PT971
PT972

Intrinsic safe protocol translator


Dual channel IS protocol translator

Galvanic barrier (single channel)

Ordering Information
GBX70

Galvanic barrier (single channel)

GBX70

Analogue Adressable Fire Detectors


Page : 72

II950

950 series mini switch monitor unit

950 series
This unit is designed to monitor the state of one or more single pole switches
connected on a single pair of cables.
Specifications

14-28 Vdc

Supply voltage
Current consumption
Quiescent (20kOhm)

1 mA

Alarm

Led /relay on

3.5 mA

Switch on surge

3 mA
9-11 Vdc
-20/+70C
0-95%
IP54

Switch monitoring
Relay contact rating
Operating temperature
Relative humidity
Ingress protection

Ordering Information
II950
II950I

950 series mini switch monitor unit


950 series mini switch monitor unit with interrupt

l
l

Loop powered
Full line: Switch monitors, Zone monitors, Input/output
unit, Output unit, Sounder circuit controller

LEDs for signalling of I/O and fault condition

Aesthetically pleasing

II952

950 series switch monitor unit - surface mount

950 series
This unit is designed to monitor the state of one or more single pole switches
connected on a single pair of cables. The circuit will report open and short-circuit
faults.
Specifications

14-28 Vdc

Supply voltage
Current consumption
Quiescent (20kOhm)

730A

Alarm
Led /relay on

5.6 mA

Switch on surge

2.5 mA
9-11 Vdc
-20/+70C
0-95%
IP54

Switch monitoring
Relay contact rating
Operating temperature
Relative humidity
Ingress protection

Ordering Information
II952
II953

950 series switch monitor unit - surface mount


Switch monitor unit plus - surface mount

Loop powered
Full line: Switch monitors, Zone monitors, Input/output
unit, Output unit, Sounder circuit controller

LEDs for signalling of I/O and fault condition

Aesthetically pleasing

Analogue Adressable Fire Detectors


Page : 73

II955

950 series zone monitor unit - surface mount

950 series
The zone monitor powers and controls the operation of a zone of conventional
detectors.
Specifications

14-28 Vdc

Supply voltage
Current consumption
Quiescent (20kOhm)

4 mA

Alarm

11-19 mA

Led /relay on

Switch on surge

2.8 mA
-20/+70C
0-95%
IP54

Switch monitoring
Relay contact rating
Operating temperature
Relative humidity
Ingress protection

Ordering Information
II955

950 series zone monitor unit - surface mount

l
l

Loop powered
Full line: Switch monitors, Zone monitors, Input/output
unit, Output unit, Sounder circuit controller

LEDs for signalling of I/O and fault condition

Aesthetically pleasing

IO950

950 series single channel IO - surface mount

950 series
This unit provides a loop-powered relay output, a monitored input and an
un-monitored opto-coupled input. It can report fault, switch open and switch closed
condition. It uses the standard housing.
Specifications

14-28 Vdc

Supply voltage
Current consumption
Quiescent (20kOhm)

1.2 mA

Alarm

Led /relay on

6 mA

Switch on surge

3.5 mA
9-11 Vdc
1A@30 Vac/dc
-20/+70C
0-95%
IP54

Switch monitoring
Relay contact rating
Operating temperature
Relative humidity
Ingress protection

Ordering Information
IO950

950 series single channel IO - surface mount

Loop powered
Full line: Switch monitors, Zone monitors, Input/output
unit, Output unit, Sounder circuit controller

LEDs for signalling of I/O and fault condition

Aesthetically pleasing

Analogue Adressable Fire Detectors


Page : 74

IO955

950 series output unit - surface mount

950 series
This unit provides a loop-powered relay output
Specifications

14-28 Vdc

Supply voltage
Current consumption
Quiescent (20kOhm)

720A

Alarm

Led /relay on

3.3 mA

Switch on surge

3 mA
1A@30 Vac/dc
-20/+70C
0-95%
IP54

Switch monitoring
Relay contact rating
Operating temperature
Relative humidity
Ingress protection

Ordering Information
IO955

950 series output unit - surface mount


l
l

Loop powered
Full line: Switch monitors, Zone monitors, Input/output
unit, Output unit, Sounder circuit controller

LEDs for signalling of I/O and fault condition

Aesthetically pleasing

IO956

950 series sounder circuit controller - surface mount

950 series
This unit is designed to control a zone of sounders powered by an external DC supply.
Specifications

14-28 Vdc

Supply voltage
Current consumption
Quiescent (20kOhm)

1.9 mA

Alarm

Led /relay on

1.7 mA

Switch on surge

2.6 mA
9-11 Vdc
-20/+70C
0-95%
IP54

Switch monitoring
Relay contact rating
Operating temperature
Relative humidity
Ingress protection

Ordering Information
l

IO956

950 series sounder circuit controller - surface mount

Loop powered
Full line: Switch monitors, Zone monitors, Input/output
unit, Output unit, Sounder circuit controller

LEDs for signalling of I/O and fault condition

Aesthetically pleasing

Analogue Adressable Fire Detectors


Page : 75

950 series loop isolator

Ordering Information
IU950

950 series loop isolator

IU950

Analogue Adressable Fire Detectors


Page : 76

AS950

950 series loop powered sounder

950 Series
Designed to operate with the 950 series analogue sensors and monitors, the AS950
loop sounders are addressed and utilise the same protocol using a very low current.
Specifications

14 - 28 V dc

Supply voltage
Current consumption
Quiescent

140 A at 24 V dc

Switch on surge

1.24 mA for 3 sec.

Operated at 85 dBA

3 mA +/- 0.25 mA

Operated at 92 dBA

8 mA +/- 0.25 mA
500 - 550 Hz (continuous mode)
IP43
-20 to 60 C
115 x 25 mm (sounder only)
115 x 33 mm (sounder with cap)
140 g (sounder only)
145 g (sounder with cap)

Drive frequency
Ingress protection
Operating temperature
Dimension (dia. x depth)
Weight

Ordering Information
AS950
AS950I
AS950W

950 series loop powered sounder


Loop powered sounder, for use with isolator base
Loop powered sounder, white cap

Loop powered

Low current consumption

Aritech 950 and Apollo protocol compatible

Continuous or pulsed tone

Sound output 85 - 92 dBA at 1 metre

Reduces wiring and installation cost

Analogue Adressable Fire Detectors


Page : 77

AS955

950 series high output loop powered sounder

950 Series
Designed to operate with the 950 series analogue sensors and monitors, the AS955
high output loop sounders are addressed and utilise the same protocol using a very
low current.
Specifications

14 - 28 V dc

Supply voltage
Current consumption
Quiescent

140 A at 24 V dc

Switch on surge

1.24 mA for 3 sec.

Operated

4.5 mA +/- 0.25 mA


500 - 550 Hz (continuous mode)
IP43
-20 to 60 C
100 dB(A)

Drive frequency
Ingress protection
Operating temperature
Sound output

Ordering Information
AS955

950 series high output loop powered sounder

Loop powered

Low current consumption

950 series protocol

Continuous or pulsed tone

Sound output 100 dB(A) at 1 metre

Reduces wiring and installation cost

Analogue Adressable Fire Detectors


Page : 78

FD950

950 series loop-powered beam detector

950 Series
A 950 series loop-powered beam detector with a range of up to 100m long and 15m
wide.

Ordering Information
FD950

950 series loop-powered beam detector

Loop-powered

950 series compatible with FP1200 and FP2000

Four selectable alarm levels

Drift compensation

Remote interface

Simple wiring

Simple alignment

Analogue Adressable Fire Detectors


Page : 79

DB950

950 series standard base

950 series
A unique, patented addressing method provides simple, user-friendly and accurate
identification of monitor location whereby a coded card, inserted in the base, is read
by any monitor as it is plugged in.

Ordering Information
DB950

950 series standard base

Passive base address

Programmable slide-in address card

Aesthetic design

EN 54,BOSEC,VdS,CNBOP approved

DB951

Base for IU 950

950 series
The isolating base senses and isolates short-circuit faults on 950 series loops and
spurs. Up to 20 devices may be placed between any two isolator bases.

Ordering Information
DB951

Base for IU 950

Passive base address

Programmable slide-in address card

Aesthetic design

EN 54,BOSEC,VdS,CNBOP approved

Analogue Adressable Fire Detectors


Page : 80

DB961

Isolating base (20 devices)

The isolating base senses and isolates short circuit faults on 950 series loops and
spurs. Up to 20 devices may be placed between any two isolator bases.

Ordering Information
DB961

Isolating base (20 devices)

Passive base address

Programmable slide-in address card

Aesthetic design

EN 54,BOSEC,VdS,CNBOP approved

DB970

Detector base for 970 series intrinsic safe sensors

Ordering Information
DB970

Detector base for 970 series intrinsic safe sensors

Passive base address

Programmable slide-in address card

Aesthetic design

EN 54,BOSEC,VdS,CNBOP approved

Analogue Adressable Fire Detectors


Page : 81

Coded cards, addresses 1 - 18

950 series
Precoded Xpert address cards for use in DB9xx bases

Ordering Information
IU980
IU981
IU982
IU983
IU984
IU985
IU986

Coded cards, addresses 1 - 18


Coded cards, addresses 19 - 36
Coded cards addresses 37 - 54
Coded cards, addresses 55 - 72
Coded cards, addresses 73 - 90
Coded cards, addresses 91- 108
Coded cards, addresses 109 - 126

IU980

FIRE PANELS & REPEATERS

CONVENTIONAL FIRE PANELS


FP200 SERIES

Conventional Fire Panels


Page : 85

FP202

Conventional fire alarm panel with 2 zones

The FP200 Series microprocessor controlled, conventional fire panels incorporate


state of the art technology, reliability, ease of installation and maintenance in a
basic package. They are compatible with conventional detectors such as the Aritech
Series 300, Series 650 and Series 700 devices. The FP202 has 2 conventional zones.
Specifications

Supply Voltage
Mains fuse (Type 5x20 mm)

125/230 VAC @ 50/60 Hz


0.5/0.25 A

Total consumption

< 20 W

Nominal Output Voltage

24 VDC

Batteries
Recommended batteries

2 off 1.9 Ah, 12 V

Fuse Rating

1A

Maximum load current

< 100 mA

Zone
Maximum Load

72 mA

Maximum number of detectors

20

Ouput voltage

22 to 28 VDC

End-of-line resitance

4k7 Ohm

Manual call point resistance

100 Ohm, 2 W

Outputs

Modern, elegant design

Compact models for 2, 4 and 6 zones

Microprocessor controlled

Fire alarm

24 VDC 15%, 300 mA

Multilingual keyboard

Fault alarm (Fail-to-safe)

24 VDC 15%, 100 mA

2 Access levels

Environmental
Working temperature

+5 to +40C

Storage temperature

-10 to +70C

Relative humidity

95 % (non-condencing)

Physical Characteristics
Size (w x h x d)

305 x 295 x 100 mm

Weight without batteries

3 kg

Acoustic indications for fire and fault

Optical indications for fire and fault by zone

Low maintenance

Ordering Information
FP202

Conventional fire alarm panel with 2 zones

Differentiation between alarms from manual call points and


automatic detectors in the same zone

Compatible with all ranges of ARITECH conventional


detectors

Conventional Fire Panels


Page : 86

FP204

Conventional fire alarm panel with 4 zones

The FP200 Series microprocessor controlled, conventional fire panels incorporate


state of the art technology, reliability, ease of installation and maintenance in a
basic package. They are compatible with conventional detectors such as the Aritech
Series 300, Series 650 and Series 700 devices. The FP204 has 4 conventional zones.
Specifications

Supply Voltage
Mains fuse (Type 5x20 mm)

125/230 VAC @ 50/60 Hz


0.5/0.25 A

Total consumption

< 20 W

Nominal Output Voltage

24 VDC

Batteries
Recommended batteries

2 off 1.9 Ah, 12 V

Fuse Rating

1A

Maximum load current

< 100 mA

Zone
Maximum Load

72 mA

Maximum number of detectors

20

Ouput voltage

22 to 28 VDC

End-of-line resitance

4k7 Ohm

Manual call point resistance

100 Ohm, 2 W

Outputs

Modern, elegant design

Compact models for 2, 4 and 6 zones

Microprocessor controlled

Fire alarm

24 VDC 15%, 300 mA

Multilingual keyboard

Fault alarm (Fail-to-safe)

24 VDC 15%, 100 mA

2 Access levels

Environmental
Working temperature

+5 to +40C

Storage temperature

-10 to +70C

Relative humidity

95 % (non-condencing)

Physical Characteristics
Size (w x h x d)

305 x 295 x 100 mm

Weight without batteries

3 kg

Acoustic indications for fire and fault

Optical indications for fire and fault by zone

Low maintenance

Ordering Information
FP204

Conventional fire alarm panel with 4 zones

Differentiation between alarms from manual call points and


automatic detectors in the same zone

Compatible with all ranges of ARITECH conventional


detectors

Conventional Fire Panels


Page : 87

FP206

Conventional fire alarm panel with 6 zones

The FP200 Series microprocessor controlled, conventional fire panels incorporate


state of the art technology, reliability, ease of installation and maintenance in a
basic package. They are compatible with conventional detectors such as the Aritech
Series 300, Series 650 and Series 700 devices. The FP206 has 6 conventional zones.
Specifications

Supply Voltage
Mains fuse (Type 5x20 mm)

125/230 VAC @ 50/60 Hz


0.5/0.25 A

Total consumption

< 20 W

Nominal Output Voltage

24 VDC

Batteries
Recommended batteries

2 off 1.9 Ah, 12 V

Fuse Rating

1A

Maximum load current

< 100 mA

Zone
Maximum Load

72 mA

Maximum number of detectors

20

Ouput voltage

22 to 28 VDC

End-of-line resitance

4k7 Ohm

Manual call point resistance

100 Ohm, 2 W

Outputs

Modern, elegant design

Compact models for 2, 4 and 6 zones

Microprocessor controlled

Fire alarm

24 VDC 15%, 300 mA

Multilingual keyboard

Fault alarm (Fail-to-safe)

24 VDC 15%, 100 mA

2 Access levels

Environmental
Working temperature

+5 to +40C

Storage temperature

-10 to +70C

Relative humidity

95 % (non-condencing)

Physical Characteristics
Size (w x h x d)

305 x 295 x 100 mm

Weight without batteries

3 kg

Acoustic indications for fire and fault

Optical indications for fire and fault by zone

Low maintenance

Ordering Information
FP206

Conventional fire alarm panel with 6 zones

Differentiation between alarms from manual call points and


automatic detectors in the same zone

Compatible with all ranges of ARITECH conventional


detectors

FIRE PANELS & REPEATERS

CONVENTIONAL FIRE PANELS


FP400 SERIES

Conventional Fire Panels


Page : 91

FP402

Conventional fire alarm panel with 2 zones

The FP400 series of conventional fire alarm and extinguishing control panels is the
ideal solution for small to medium-sized installations. Very powerful and
cost-effective, they are extremely simple to install and use due to their ergonomic,
advanced design. The panels come in elegant, high-quality, conveniently sized,
heavy-duty metal enclosures with space for batteries and finished in high-gloss
paint. All panels have a high-quality keyboard with audible metallic click and good
travel
Specifications

Supply Voltage (+10% - 15%)


Batteries

230 / 110 VAC @ 50 / 60 Hz

Capacity

2 x 2.3 Ah

Fuse rating

2A

Zone
Maximum load

94 mA

Max. number of detectors per zone 20


Maximum zone resistance

44 ohm

Sounders
Maximum load

250 mA

Delay

Selectable 0 - 9 min

Relay Outputs (excluding sounders)


Extinguishing Relay Outputs

Modern, attractive design

Microprocessor controlled

From 2 up to 16 zones

EN54 compliant with approvals pending

2 Access levels

2 Monitored sounder outputs

One-man test capability

24 Volt resetable output

External 'class change' facility

Alarm output with potential free relay

General fault output with potential free relay

External watchdog

1 A @ 30 VDC

Maximum load

NA

Fuse rating

NA

Auxilliary Output
24 VDC Resetable Output

250 mA

Maximum Load

100 mA

Reset time

3s

Environment
Working temperature

-5C to +40C

Relative humidity (non condencing) 95 %


IP rating

IP30

Physical Characteristics
Size (mm)

297 (w) x 307 (h) x 105 (d)

Weight (without batteries)

3.6 kg

Ordering Information
FP402
FP404

Conventional fire alarm panel with 2 zones


Conventional fire alarm panel with 4 zones

Conventional Fire Panels


Page : 92

FP408

Conventional fire alarm panel with 8 zones

The FP400 series of conventional fire alarm and extinguishing control panels is the
ideal solution for small to medium-sized installations. Very powerful and
cost-effective, they are extremely simple to install and use due to their ergonomic,
advanced design. The panels come in elegant, high-quality, conveniently sized,
heavy-duty metal enclosures with space for batteries and finished in high-gloss
paint. All panels have a high-quality keyboard with audible metallic click and good
travel
Specifications

Supply Voltage (+10% - 15%)


Batteries

230 / 110 VAC @ 50 / 60 Hz

Capacity

2 x 7.5 Ah

Fuse rating

5A

Zone
Maximum load

94 mA

Max. number of detectors per zone 20


Maximum zone resistance

44 ohm

Sounders
Maximum load

250 mA

Delay

Selectable 0 - 9 min

Relay Outputs (excluding sounders)


Extinguishing Relay Outputs

Modern, attractive design

Microprocessor controlled

From 2 up to 16 zones

EN54 compliant with approvals pending

2 Access levels

2 Monitored sounder outputs

One-man test capability

24 Volt resetable output

External 'class change' facility

Alarm output with potential free relay

General fault output with potential free relay

External watchdog

1 A @ 30 VDC

Maximum load

NA

Fuse rating

NA

Auxilliary Output
24 VDC Resetable Output

250 mA

Maximum load

100 mA

Reset time

3s

Environment
Working temperature

-5C to +40C

Relative humidity (non condencing) 95 %


IP rating

IP30

Physical Characteristics
Size (mm)

420 (w) x 335 (h) x 110 (d)

Weight (without batteries)

6.2 kg

Ordering Information
FP408

Conventional fire alarm panel with 8 zones

Conventional Fire Panels


Page : 93

FP412

Conventional fire alarm panel with 12 zones

The FP400 series of conventional fire alarm and extinguishing control panels is the
ideal solution for small to medium-sized installations. Very powerful and
cost-effective, they are extremely simple to install and use due to their ergonomic,
advanced design. The panels come in elegant, high-quality, conveniently sized,
heavy-duty metal enclosures with space for batteries and finished in high-gloss
paint. All panels have a high-quality keyboard with audible metallic click and good
travel
Specifications

Supply Voltage (+10% - 15%)


Batteries

230 / 110 VAC @ 50 / 60 Hz

Capacity

2 x 7.5 Ah

Fuse rating

5A

Zone
Maximum load

94 mA

Max. number of detectors per zone 20


Maximum zone resistance

44 ohm

Sounders
Maximum load

250 mA

Delay

Selectable 0 - 9 min

Relay Outputs (excluding sounders)


Extinguishing Relay Outputs

Modern, attractive design

Microprocessor controlled

From 2 up to 16 zones

EN54 compliant with approvals pending

2 Access levels

2 Monitored sounder outputs

One-man test capability

24 Volt resetable output

External 'class change' facility

Alarm output with potential free relay

General fault output with potential free relay

External watchdog

1 A @ 30 VDC

Maximum load

NA

Fuse rating

NA

Auxilliary Output
24 VDC Resetable Output

250 mA

Maximum load

100 mA

Reset time

3s

Environment
Working temperature

-5C to +40C

Relative humidity (non condencing) 95 %


IP rating

IP30

Physical Characteristics
Size (mm)

420 (w) x 335 (h) x 110 (d)

Weight (without batteries)

6.2 kg

Ordering Information
FP412

Conventional fire alarm panel with 12 zones

Conventional Fire Panels


Page : 94

FP416

Conventional fire alarm panel with 16 zones

The FP400 series of conventional fire alarm and extinguishing control panels is the
ideal solution for small to medium-sized installations. Very powerful and
cost-effective, they are extremely simple to install and use due to their ergonomic,
advanced design. The panels come in elegant, high-quality, conveniently sized,
heavy-duty metal enclosures with space for batteries and finished in high-gloss
paint. All panels have a high-quality keyboard with audible metallic click and good
travel
Specifications

Supply Voltage (+10% - 15%)


Batteries

230 / 110 VAC @ 50 / 60 Hz

Capacity

2 x 7.5 Ah

Fuse rating

5A

Zone
Maximum load

94 mA

Max. number of detectors per zone 20


Maximum zone resistance

44 ohm

Sounders
Maximum load

250 mA

Delay

Selectable 0 - 9 min

Relay Outputs (excluding sounders)


Extinguishing Relay Outputs

Modern, attractive design

Microprocessor controlled

From 2 up to 16 zones

EN54 compliant with approvals pending

2 Access levels

2 Monitored sounder outputs

One-man test capability

24 Volt resetable output

External 'class change' facility

Alarm output with potential free relay

General fault output with potential free relay

External watchdog

1 A @ 30 VDC

Maximum load

NA

Fuse rating

NA

Auxilliary Output
24 VDC Resetable Output

250 mA

Maximum load

100 mA

Reset time

3s

Environment
Working temperature

-5C to +40C

Relative humidity (non condencing) 95 %


IP rating

IP30

Physical Characteristics
Size (mm)

420 (w) x 335 (h) x 110 (d)

Weight (without batteries)

6.2 kg

Ordering Information
FP416

Conventional fire alarm panel with 16 zones

Conventional Fire Panels


Page : 95

RB404

Relay module, 4 potential free relays for NK700/Fx400 fire panels

The RB404 relay expander module has voltage-free 4 relays. The unit allows for a
relay for each detection zone or for programming the activation of different relays
depending on the status of one or more zones. It is used on the GE-Interlogix
NK700/FP400 conventional fire panel range.
Specifications

Relay Rating
Voltage

230 VDC

Current

2A
0 to 9 minutes

Delay setting

Ordering Information
RB404

Relay module, 4 potential free relays for NK700/Fx400 fire panels

l
l

4 Potential free relays


Up to 4 modules may be housed inside the fire panel
cabinet

Programable with basic boolen functions

Power supplied from fire panel bus

Output delay setting per relay

Conventional Fire Panels


Page : 96

SB404

Relay module, 4 supervised relays for NK700/Fx400 fire panels

The SB404 module has 4 relays that provide 4 of 24 VDC supervised outputs. These
may be configured to power sounders or as standard 24 VDC supervised outputs for
other devices.
Specifications

24 VDC
0 to 9 minutes

Aux. Supply
Delay Setting

Ordering Information
SB404

Relay module, 4 supervised relays for NK700/Fx400 fire panels

l
l

4 Supervised relays
Up to 4 modules may be housed inside the fire panel
cabinet

Programable with basic boolen functions

Output delay setting per relay

Configurable for sounder control or as supervised outputs

Conventional Fire Panels


Page : 97

Conventional fire detection and extinguishing control panel with 3 zones including 1 extinguishing zone

FEC403

The FP400 series of conventional fire alarm and extinguishing control panels is the
ideal solution for small to medium-sized installations. Very powerful and
cost-effective, they are extremely simple to install and use due to their ergonomic,
advanced design. The panels come in elegant, high-quality, conveniently sized,
heavy-duty metal enclosures with space for batteries and finished in high-gloss
paint. All panels have a high-quality keyboard with audible metallic click and good
travel
Specifications

Supply Voltage (+10% - 15%)


Batteries

230 / 110 VAC @ 50 / 60 Hz

Capacity

2 x 7 Ah

Fuse rating

2A

Zone
Maximum load

94 mA

Max. number of detectors per zone 20


Maximum zone resistance

44 ohm

Sounders
Maximum load

250 mA

Delay

Selectable 0 - 9 min

Relay Outputs (excluding sounders)


Extinguishing Relay Outputs

Modern, attractive design

Microprocessor controlled

3 zone (1 ext. area) and 6 zone (2 ext. areas) available

Automatic extinguishing agent release control

EN54 compliant

2 Access levels

Supervised general sounder output

Supervised extinguishing inputs and outputs

One-man test capability

24 Volt resetable output

External 'class change' facility

Alarm output with potential free relay

General fault output with potential free relay

External watchdog

1 A @ 30 VDC

Maximum load

350 mA

Fuse rating

1A

Auxilliary Output
24 VDC Resetable Output

250 mA

Maximum Load

100 mA

Reset time

3s

Environment
Working temperature

-5C to +40C

Relative humidity (non condencing) 95 %


IP rating

IP30

Physical Characteristics
Size (mm)

420 (w) x 335 (h) x 110 (d)

Weight (without batteries)

6.2 kg

Ordering Information
FEC403

Conventional extinguishing control panel with 3 zones

Conventional Fire Panels


Page : 98

FEC406

Conventional extinguishing control panel with 6 zones

The FP400 series of conventional fire alarm and extinguishing control panels is the
ideal solution for small to medium-sized installations. Very powerful and
cost-effective, they are extremely simple to install and use due to their ergonomic,
advanced design. The panels come in elegant, high-quality, conveniently sized,
heavy-duty metal enclosures with space for batteries and finished in high-gloss
paint. All panels have a high-quality keyboard with audible metallic click and good
travel
Specifications

Supply Voltage (+10% - 15%)


Batteries

230 / 110 VAC @ 50 / 60 Hz

Capacity

2 x 7 Ah

Fuse rating

2A

Zone
Maximum load

94 mA

Max. number of detectors per zone 20


Maximum zone resistance

44 ohm

Sounders
Maximum load

250 mA

Delay

Selectable 0 - 9 min

Relay Outputs (excluding sounders)


Extinguishing Relay Outputs

Modern, attractive design

Microprocessor controlled

3 zone (1 ext. area) and 6 zone (2 ext. areas) available

Automatic extinguishing agent release control

EN54 compliant

2 Access levels

Supervised general sounder output

Supervised extinguishing inputs and outputs

One-man test capability

24 Volt resetable output

External 'class change' facility

Alarm output with potential free relay

General fault output with potential free relay

External watchdog

1 A @ 30 VDC

Maximum load

350 mA

Fuse rating

1A

Auxilliary Output
24 VDC Resetable Output

250 mA

Maximum Load

100 mA

Reset time

3s

Environment
Working temperature

-5C to +40C

Relative humidity (non condencing) 95 %


IP rating

IP30

Physical Characteristics
Size (mm)

420 (w) x 335 (h) x 110 (d)

Weight (without batteries)

6.2 kg

Ordering Information
FEC406

Conventional extinguishing control panel with 6 zones

FIRE PANELS & REPEATERS

CONVENTIONAL FIRE PANELS


FP600 SERIES

Conventional Fire Panels


Page : 101

FP604

4-zone Conventional Fire Panel

The FP 604 fire panel is designed using the latest technologies and is compatible
with most brands of conventional fire detectors. The FP 604 is a 4-zone panel which
is extendable up to 6 zones.
Specifications

230 V ( 10% - 50 Hz 5%)


Supply voltage
80 mA
Total current 12 V dc (no charge), quiescent
90 mA
Total current 24 V dc (no charge), quiescent
100 mA - 12 V dc
Auxiliary output
1 x 12 V - 7.2 Ah battery
Battery back-up for 72 hrs
2A
Battery charger fuse
13.8 V
Battery charger voltage
315 mA
Bells - Fire Brigade fuse
390 x 315 x 85 mm
Dimensions

Ordering Information
FP604
ZI602
RC606

4-zone Conventional Fire Panel


Two zone extension board, including 6 outputs
Set of 6 bi-stable magnetic latch relays

One man maintenance

Alarm verification

Individual zone alarm outputs

One 12 V back-up battery

12 V dc auxiliary output

4 - 6 zones

Mixed zone capability

Head removal option

Sirens output 12 or 24 V dc

Microprocessor based

EN 54 p2/4 approved

LPCB certified

Optional third source

Optional digital dialler

Conventional Fire Panels


Page : 102

Two zone extension board, including 6 outputs

ZI602

This board extends the FP604 from 4 zones to 6 zones. It also provides 6 outputs for
the 6 zones.

Ordering Information
ZI602

Two zone extension board, including 6 outputs

Set of 6 bi-stable magnetic latch relays

A set of 6 relays for the ZI602 zone extension board

Ordering Information
RC606

Set of 6 bi-stable magnetic latch relays

RC606

FIRE PANELS & REPEATERS

CONVENTIONAL FIRE PANELS


FP700 SERIES

Conventional Fire Panels


Page : 105

FP708

Fire panel equipped with 8 zones

FP700 series
A set of four conventional fire panels. The FP708 and FP708C are 8 zone
non-expandable fire panels. The FP740 and FP740C are 8 zone expandable to 40
zones. The FP708C and FP740C have an alarm counter. All panels can use the full
range of LON700 output boards.
Specifications

444 x 340 x110 mm


Dimensions (W x H x D)
5.5 kg
Weight (no batteries)
Supply voltage (see engineering guide) 230 V ac; 1,5 A; 50 Hz
210 mA (8 zones)
Quiescent current @20 devices/zone
7.2 Ah
Batteries for 24 hrs (in housing)
17 Ah
Batteries for 72 hrs
1.4 A max
Battery charger rating
Nominal battery charger voltage @ 25C27,6 V
21 - 29,4 V dc; 1.2 A max.
Auxiliary output 1
11.5 - 12.5 V dc; 0.4 A max.
Auxiliary output 2
3,5 A max
Total 24 V output (no charging)
0,5 A, 19-31 V dc, polarity reversal
Sounder/warning
0,5 A, 19-31 V dc, polarity reversal
Evacuation/Fire brigade
2 A, @ 42 V
Fault and Fire protection relay rating
19200 baud, DB9, 1 start, 8 data, 1 stop, no parity
RS 232 port

Ordering Information
FP708
FP708C
FP740
FP740C

Fire panel equipped with 8 zones


Fire panel equipped with 8 zones including alarm counter
Fire panel equipped with 8 zones expandable up to 40 zones
Fire panel equipped with 8 zones exp. to 40 including alarm counter

Fully modular

Echelon based network

One Man maintenance

Alarm verification

700 series detectors Clean Me detection

Various output boards

Approved BOSEC

Complies to EN 54 p2/p4

Modular up to 40 zones

Full line of repeaters

Microprocessor based

Local and remote control

Conventional Fire Panels


Page : 106

FR708

Repeater 8 zones, 24 VDC input

FR700 series
The repeaters provide different solutions - 24 volt input and 230 volt input using the
PS700 power supply. The FR708 is 8 zones non expandable and the FR740 is 8 zones
expandable to 40 zones. The FR700 repeaters connect to the FP700 fire panel with
the LON 700 bus. The FR708V230 and FR740V230 include a card cage for LON board
expansion and have a PS700 power supply.

Ordering Information
FR708
FR708V230
FR740
FR740V230

Repeater 8 zones, 24 VDC input


Repeater 8 zones with card cage and PS700 PSU (230V input)
Repeater 8 zones, expandable up to 40 zones, 24 VDC input
Repeater 8 zones, exp to 40 zones with card cage and PS700 PSU (230V)

Fully modular

Echelon based network

Various output boards

Modular up to 40 zones

Full line of repeaters

Microprocessor based

Local and remote control

Conventional Fire Panels


Page : 107

8 zone indicator LED extension board fire/fault

ZE708

FP700 series
This zone indicator extension board is used to expand the FP740 and FR740 front
panel indications.

Ordering Information
ZE708

8 zone indicator LED extension board fire/fault

8 zone input extension board

FP700 series
An eight zone input expansion board for FP740 fire panels.

Ordering Information
ZI708

8 zone input extension board

ZI708

Conventional Fire Panels


Page : 108

Synoptic driver for 80 LEDs and common signals

FM740

LON 700 series


A LON700 output board to display LED's. It can be self-standing as well as plugging
into a card cage.
Specifications

Dimensions mm (L x W x D)
Weight
Operating temp C
Operating voltage Vdc
Current consumption

150x30x60
200 g
-5C - +40
19 - 30

max quiesent mA

30

power consumption per LED (mW)

40

Bus Connection
FP1200/FP2000 (with LON2000)

***

FP700 (direct connection)

***

Bus Cable
Total number of repeaters

Cat 5

FP1200/FP2000

15

FP700

Ordering Information
FM740

Synoptic driver for 80 LEDs and common signals

LON700 output board with 24 open collector outputs

LON700 series
A 24 way open collector board used in a LON700 system

Ordering Information
OCB724

LON700 output board with 24 open collector outputs

OCB724

Conventional Fire Panels


Page : 109

LON700 output board with 8 relays

RB708

LON700 series
An eight way relay board used in LON700 systems

Ordering Information
RB708

LON700 output board with 8 relays

LON700 output board with 8 supervised outputs

LON700 series
Eight supervised outputs that can be used in LON700 systems

Ordering Information
SOB708

LON700 output board with 8 supervised outputs

SOB708

Conventional Fire Panels


Page : 110

FB708

FP700 black box with 7 slot card cage

LON700 series
The FB708 and FB740 'black boxes' allow for the distribution of LON700 input /
output units. When used with the NC700 or FM740, the FB7xx is connected to the
FP700 / FP2000 firepanels with the LON700 bus.

Ordering Information
FB708
FB740
NC700

FP700 black box with 7 slot card cage


FP700 black box with 11 slot card cage and PS700
LON 700 interface board

Fully modular

Echelon based network

Various output boards

Microprocessor based

Local and remote control

For fire panel distributed systems

7 slot card cage or 11 slot card cage with power supply

Conventional Fire Panels


Page : 111

LON 700 interface board

NC700

LON700 series
An interface board to connect a LON bus from a fire panel to a FB7xx 'black box'

Ordering Information
NC700
FB708
FB740

LON 700 interface board


FP700 black box with 7 slot card cage
FP700 black box with 11 slot card cage and PS700

Plug-in power supply 3.5 A

LON700 series
This power supply can be used to extend the power output in LON700 systems. It is
standard in the FP700 and FR700V230 systems, as well the FB740 'black box'.

Ordering Information
PS700

Plug-in power supply 3.5 A

PS700

FIRE PANELS & REPEATERS

ANALOGUE ADDRESSABLE FIRE PANELS


FP1500 SERIES

Analogue Adressable Fire Panels


Page : 115

FP1501

Analogue addressable fire detection panel - 1 loop

The FP1501 1 loop analogue addressable fire alarm control panel is the ideal solution
for small to medium-sized installations. Very powerful and cost-effective, it is
extremely simple to install and use due to is ergonomic, advanced design. The panel
is supplied in an elegant, high-quality, conveniently sized, heavy-duty enclosure. It
has a high-quality keyboard with audible metallic click and good travel.
Specifications

110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)


175 mA Quiescent / 241 mA in alarm with no devices
connected

Supply Voltage
Current Consumption
Batteries
Capacity

2 x 12 V - 7 AH (SLA type)

Fuse Rating

3A

Charger Rating

350 mA @ 27.6 VDC @ 20 C (Temperature


compensated -3 V / C)

Loop characteristics per loop


Capacity

250 addresses per loop

Maximum Load

400 mA / 26 VDC to 32 VDC

Maximum Electrical Characteristics 44 Ohm / 500 nF approximately 2 km of 1.5 mm2


diameter cable
Sounders (reverse polarity supervision)
Maximum Load
Delays
Relay Outputs (potential free)
24 V Auxiliary Output
Maximum Load

250 mA each (2 Sounder outputs available) / 18 VDC to


24 VDC
10 seconds to 600 seconds, software adjustable in 10
second intervals
1 A @ 30 VDC
250 mA @ 18 VDC to 28 VDC

Modern, attractive design

4 x 40 characters LCD display

20 Display zones

EN54 compliant with approvals pending

3 User access levels

2 Monitored sounder outputs

2 Programmable voltage free relays

24 Volt auxiliary output

I/O programming capabilities with Boolean functions

Day/night sensitivity settings

Coincidence within zones

Upload/download and graphic PC software

Panel networking

Installation test capability

Environment
Working Temperature

-5C to +40 C

Relative Humidity

0-95% non-condensing

IP Rating

IP30

Physical Characteristics
Size

420 mm (w) x 335 (h) x 110 (d)

Weight

6.2 kg without batteries / 10.7 kg with 2 x 7 Ah batteries

Ordering Information
FP1501

Analogue addressable fire detection panel - 1 loop

Analogue Adressable Fire Panels


Page : 116

FP1502

Analogue addressable fire detection panel - 2 loops

The FP1500 series analogue addressable fire alarm control panels is the ideal
solution for small to medium-sized installations. Very powerful and cost-effective,
they are extremely simple to install and use due to their ergonomic, advanced design.

The panels are supplied in an elegant, high-quality, conveniently sized, heavy-duty


metal enclosure and are finished in a high-gloss paint. All panels have a high-quality
keyboard with audible metallic click and good travel.
The batteries for the system may be housed inside the cabinet.
Specifications

110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)


175 mA Quiescent / 241 mA in alarm with no devices
connected

Supply Voltage
Current Consumption
Batteries
Capacity

2 x 12 V - 7 AH (SLA type)

Fuse Rating

3A

Charger Rating

350 mA @ 27.6 VDC @ 20 C (Temperature


compensated -3 V / C)

Loop characteristics per loop


Capacity

250 addresses per loop

Maximum Load

400 mA / 26 VDC to 32 VDC

Maximum Electrical Characteristics 44 Ohm / 500 nF approximately 2 km of 1.5 mm2


diameter cable
Sounders (reverse polarity supervision)
Maximum Load
Delays
Relay Outputs (potential free)
24 V Auxiliary Output
Maximum Load

250 mA each (2 Sounder outputs available) / 18 VDC to


24 VDC
10 seconds to 600 seconds, software adjustable in 10
second intervals
1 A @ 30 VDC
250 mA @ 18 VDC to 28 VDC

Modern, attractive design

4 x 40 characters LCD display

20 Display zones

EN54 compliant with approvals pending

3 User access levels

2 Monitored sounder outputs

2 Programmable voltage free relays

24 Volt auxiliary output

I/O programming capabilities with Boolean functions

Day/night sensitivity settings

Coincidence within zones

Upload/download and graphic PC software

Panel networking

Installation test capability

Environment
Working Temperature

-5C to +40 C

Relative Humidity

0-95% non-condensing

IP Rating

IP30

Physical Characteristics
Size

420 mm (w) x 335 (h) x 110 (d)

Weight

6.2 kg without batteries / 10.7 kg with 2 x 7 Ah batteries

Ordering Information
FP1502

Analogue addressable fire detection panel - 2 loops

Analogue Adressable Fire Panels


Page : 117

NC785

RS485 Expansion kit for KSA701/FP1500 fire panels

The NC785 RS485 expander allows for an easy upgrade to the KSA701/FP1500 series
analalogue addressable fire panels. Each module adds an additional industry
standard RS485 communication port to the panel. This port could be used for
communications with other network nodes in the fire panel network.
Specifications

Number of ports
Communications medium
Technical specifications

1
RS485

Maximum cable length

1200 m

Communication speed

9600 baud

Cable

CAT5 - twisted with screen

Termination resistance

150 Ohm

Ordering Information
NC785

RS485 expansion kit for KSA701/FP1500 fire panels


l

Industry standard RS485 communications

No hardware configuration required

Analogue Adressable Fire Panels


Page : 118

FR1500

Analogue addressable LCD Repeater/Emulator*

The FP1500 Series analogue addressable fire alarm panels are the ideal solution for
small to medium-sized installations. Very powerful and cost-effective, they are easy
to install and use due to their ergonomic, advanced design. The FR1500 LCD repeater
is supplied in the same enclosure as the FP1500.
Specifications

Supply Voltage
AC Version

110 VAC @ 50 Hz or 230 VAC @ 50 Hz (+10% -15%)

DC Version

24 VDC

Current Consumption
Battery Charger (AC Version only)

175 mA Quiescent / 200 mA in alarm

Capacity

2 x 12 V - 7 AH (SLA type)

Fuse Rating

3A

Charger Rating

350 mA @ 27.6 VDC @ 20 C (Temperature


compensated -3 V / C)

Environment
Working Temperature

-5C to +40 C

Relative Humidity

0-95% non-condensing

IP Rating

IP30

Physical Characteristics
Size

420 mm (w) x 335 (h) x 110 (d)

Weight

6.2 kg without batteries / 10.7 kg with 2 x 7 Ah batteries

Modern, attractive design

4 x 40 characters LCD display

20 Display zones

EN54 compliant with approvals pending

3 User access levels

24 VDC or 230 VAC models available

Panel networking

Full system control

RS232 and RS485 standard

Communication Ports

Ordering Information
FR1500

Analogue addressable LCD Repeater/Emulator

Analogue Adressable Fire Panels


Page : 119

MODGSM

GSM Modem for Kilsen Fire Panels

The MODGSM modem may be used in KSA701/FP1500, KSA702 and KSA705 fire panel
from GE-Interlogix. It is ideal for use as a standard modem for making and receiving
calls from and to the fire panel, but may also be used for GSM messaging.
Specifications

900/1800 MHz
Data, SMS, Voice and Fax
GSM 07.07 and 07.05

GSM Band
Services
AT Commands
Output Power (max)
GSM900

2W

GSM1800

1W
5 to 32 V

Input Voltage
Current @ 5V
Avarage

330 mA

Peak

1.8 A

SIM Interface
Dimensions (h x w x d)
Weight
Environmental Temperature

3V / 5V
98 x 54 x 25 mm
130 g

Storage

- 25 C to + 70 C

Operating

- 20 C to + 55 C

Ordering Information
MODGSM

GSM Modem for Kilsen Fire Panels

Dual-Band 90/1800 MHz

Data and SMS services

Remote control by AT commands

Wide input voltage range

Analogue Adressable Fire Panels


Page : 120

Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops)

PCG-Graphic102

The PCG-Config series consists of 3 software applications. The individual software


formats allows the graphic package to grow with the installation. PCG-Config102
operates with a single panel and allows for the configuration of all devices up to a
maximum of two loops.
Specifications

Hardware Requirements
Communication

RS232, Modem and/or TCP/IP

Display

SVGA or higher resolution

Hard Disk

2 GB with 650 MB free space

Keyboard

Required

Pointing Device

Required

Printer

System printer required for printing

Processor

1 GHz or higher Pentium III-compatible CPU

RAM

256 Mb or more

Removable Media

1.44 Mb stiffy and CD-ROM or DVD drive

Software Requirements
Operating System

Windows '98 or Windows 2000

Ordering Information
PCG-Graphic102

Bi-directional communication with single panels and


networked fire systems

Local or remote connection via modem or TCP/IP

Large selection of user configurable icons

Visualises device alarms and status of in- and outputs

Event texts retrieval from the panel

Configurator and operator contol levels

Navigation buttons allowed

Event logs with reporting facilities

Basic drawing package included

Imports bmp & drw format graphics

Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops)

Analogue Adressable Fire Panels


Page : 121

Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops)

PCG-Graphic105

The PCG-Config series consists of 3 software applications. The individual software


formats allows the graphic package to grow with the installation. PCG-Config105
supports a single panel up to 5 loops.
Specifications

Hardware Requirements
Communication

RS232, Modem and/or TCP/IP

Display

SVGA or higher resolution

Hard Disk

2 GB with 650 MB free space

Keyboard

Required

Pointing Device

Required

Printer

System printer required for printing

Processor

1 GHz or higher Pentium III-compatible CPU

RAM

256 Mb or more

Removable Media

1.44 Mb stiffy and CD-ROM or DVD drive

Software Requirements
Operating System

Windows '98 or Windows 2000


l

Ordering Information
PCG-Graphic105

Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops)

Bi-directional communication with single panels and


networked fire systems

Local or remote connection via modem or TCP/IP

Large selection of user configurable icons

Visualises device alarms and status of in- and outputs

Event texts retrieval from the panel

Configurator and operator contol levels

Navigation buttons allowed

Event logs with reporting facilities

Basic drawing package included

Imports bmp & drw format graphics

Analogue Adressable Fire Panels


Page : 122

PCG-GraphicNW

Graphic Software for KSA700/FP1500 Fire Systems (multi-panel)

The PCG-Config series consists of 3 software applications. The individual software


formats allows the graphic package to grow with the installation. PCG-ConfigNW
allows for monitoring on networked systems with multiple panels.
Specifications

Hardware Requirements
Communication

RS232, Modem and/or TCP/IP

Display

SVGA or higher resolution

Hard Disk

2 GB with 650 MB free space

Keyboard

Required

Pointing Device

Required

Printer

System printer required for printing

Processor

1 GHz or higher Pentium III-compatible CPU

RAM

256 Mb or more

Removable Media

1.44 Mb stiffy and CD-ROM or DVD drive

Software Requirements
Operating System

Windows '98 or Windows 2000


l

Ordering Information
PCG-GraphicNW

Graphic Software for KSA700/FP1500 Fire Systems (multi-panel)

Bi-directional communication with single panels and


networked fire systems

Local or remote connection via modem or TCP/IP

Large selection of user configurable icons

Visualises device alarms and status of in- and outputs

Event texts retrieval from the panel

Configurator and operator contol levels

Navigation buttons allowed

Event logs with reporting facilities

Basic drawing package included

Imports bmp & drw format graphics

FIRE PANELS & REPEATERS

ANALOGUE ADDRESSABLE FIRE PANELS


FP1200/2000 SERIES

Analogue Adressable Fire Panels


Page : 125

FP1216EN

Analogue panel, 2- 4 loop, 16 zones

FP1216 series
A versatile, cost effective analogue addressable fire panel, 2 to 4 loops, giving
powerfull features
Specifications

Supply voltage

Min. supply current @ 24 V dc


Battery charger rating @ 27.6 V dc
Total supply rating @ 27.6 V dc
Relay rating @ 24 V dc
Weight (no batteries)
Dimensions (mm H x W x D)

230 V ac (+10/-15%)
50 Hz
220 VA
0.2 A
1.6 A
4A
2A
7.5 kg
440 x 444 x 125

Ordering Information
FP1216EN

Analogue panel, 2-4 loop, 16 zones

One man maintenance

Soak test

On-line diagnostics and statistics

Power supply for 72 hour autonomy

Floating background for 2000 series sensors

Coincidence within and in between zones

Start-up default mode

Upload/download

I/O programming including Boolean functions

EN 54 p2 & 4 approved

2 or 4 class A loops

Analogue Adressable Fire Panels


Page : 126

FP2416

Analogue adressable fire panel - 2 to 4 loops. 16 zones

FP2000 Series
Specifications

190 - 270 V ac
40- 60 Hz
160 VA max.
21 - 27 V dc

Supply voltage 1

Supply voltage 2
Current consumption

Quiescent @ 24 V dc (Fully equipped500


loop)mA
Alarm current @ 24 V dc
Available auxiliary current in alarm
Battery charger rating @ 27.5 V dc
Total supply rating @ 27.5 V dc
Relay rating @ 24 V dc
Weight (no batteries)
Dimensions (mm) (H x W x D)

600 mA
3.4 A
3A
4A
2A
11 kg
609 x 441 x 109

Ordering Information
FP2416

Analogue adressable fire panel - 2 to 4 loops. 16 zones

One man maintenance

Graphic maintenance

Maintenance warning

Service reminder signal

Soak test

On-line diagnostics and statistics

Floating background

Day/night sensitivity setting

Coincidence within and in between zones

Automatic timed and manual on/off zones

Start-up default mode

Service switch

Upload/download, remote maintenance and graphic PC


software

I/O programming including Boolean functions

ARCNET panel networking

EN 54 approved; certified Bosec, VdS, NFA2P

Networkable "black box" and "global zone" system

Full range of repeater panels

Analogue Adressable Fire Panels


Page : 127

FP2432

Analogue addressable panel - 2 to 4 loops, 16 to 32 zones

FP2000 Series
Specifications

190 - 270 V ac
40- 60 Hz
160 VA max.
21 - 27 V dc

Supply voltage 1

Supply voltage 2
Current consumption

Quiescent @ 24 V dc (Fully equipped500


loop)mA
Alarm current @ 24 V dc
Available auxiliary current in alarm
Battery charger rating @ 27.5 V dc
Total supply rating @ 27.5 V dc
Relay rating @ 24 V dc
Weight (no batteries)
Dimensions (mm H x W x D)

600 mA
3.4 A
3A
4A
2A
11 kg
609 x 441 x 109

Ordering Information
FP2432

Analogue addressable panel - 2 to 4 loops, 16 to 32 zones

One man maintenance

Graphic maintenance

Maintenance warning

Service reminder signal

Soak test

On-line diagnostics and statistics

Floating background

Day/night sensitivity setting

Coincidence within and in between zones

Automatic timed and manual on/off zones

Start-up default mode

Service switch

Upload/download, remote maintenance and graphic PC


software

I/O programming including Boolean functions

ARCNET panel networking

EN 54 approved; certified Bosec, VdS, NFA2P

Networkable "black box" and "global zone" system

Full range of repeater panels

Analogue Adressable Fire Panels


Page : 128

FP2864

Analogue addressable fire panel - 2 to 8 loops. 16 - 64 zones

FP2000 series
Specifications

190 - 270 V ac
40 - 60 Hz
160 VA max.
21 - 27 V dc

Supply voltage 1

Supply voltage 2
Current consumption

Quiescent @ 24 V dc (Fully equipped800


loop)mA
Alarm current @ 24 V dc
Available auxiliary current in alarm
Battery charger rating @ 27.5 V dc
Total supply rating @ 27.5 V dc
Relay rating @ 24 V dc
Weight (no batteries)
Dimensions (mm) (H x W x D)

1A
3A
3A
4A
2A
15 kg
804 x 441 x 109

Ordering Information
FP2864

Analogue addressable fire panel - 2 to 8 loops. 16 - 64 zones

One man maintenance

Graphic maintenance

Maintenance warning

Service reminder signal

Soak test

On-line diagnostics and statistics

Floating background

Day/night sensitivity setting

Coincidence within and in between zones

Automatic timed and manual on/off zones

Start-up default mode

Service switch

Upload/download, remote maintenance and graphic PC


software

I/O programming including Boolean functions

ARCNET panel networking

EN 54 approved; certified Bosec, VdS, NFA2P

Networkable "black box" and "global zone" system

Full range of repeater panels

Analogue Adressable Fire Panels


Page : 129

FB2400

Analogue addressable fire panel - 2 to 4 loops, 'black box'

FP2000 series
The FB2400 / FB2800 'black box' system allows a cost-effective network of fire panels
to be interconnected to a global repeater
Specifications

190 - 270 V ac
40- 60 Hz
160 VA max.
21 - 27 V dc

Supply voltage 1

Supply voltage 2
Current consumption

500 mA
Quiescent @ 24 V dc (Fully equipped loop)
600 mA
Alarm current @ 24 V dc
3.4 A
Available auxiliary current in alarm
3A
Battery charger rating @ 27.5 V dc
4A
Total supply rating @ 27.5 V dc
2A
Relay rating @ 24 V dc
11 kg
Weight (no batteries)
609 x 441 x 109
Dimensions (mm H x W x D)

Ordering Information
FB2400
FB2800

Analogue addressable fire panel - 2 to 4 loops, 'black box'


Analogue addressable fire panel - 2 to 8 loops, 'black box'

One man maintenance

Graphic maintenance

Maintenance warning

Service reminder signal

Soak test

On-line diagnostics and statistics

Floating background

Day/night sensitivity setting

Coincidence within and in between zones

Automatic timed and manual on/off zones

Start-up default mode

Service switch

Upload/download, remote maintenance and graphic PC


software

I/O programming including Boolean functions

ARCNET panel networking

EN 54 approved; certified Bosec, VdS, NFA2P

Networkable "black box" and "global zone" system

Full range of repeater panels

Analogue Adressable Fire Panels


Page : 130

2-loop extension board for FP1200 / FP2000 fire panels

LC2002

FP1200 / FP2000 series


Specifications

Current consumption
Quiescent @ 24 V dc (Fully equipped+loop)
150 mA (252 detectors)

Ordering Information
LC2002

2-loop extension board for FP1200 / FP2000 fire panels

16-zone LED extension fire and fault LED

FP1200 / FP2000 series


Extends the zones of the FP 2x32 and 2x64

Ordering Information
ZE2016

16-zone LED extension fire and fault LED

ZE2016

Analogue Adressable Fire Panels


Page : 131

LON700 driver for FP1200 / FP2000

LON2000

FP1200 / FP2000 series


A LON700 driver that connects FP1200 / FP2000 fire panels to LON700 devices

Ordering Information
LON2000

LON700 driver for FP1200 / FP2000

ARCNET RS 485 network card with single, RS 485 interface

FP1200 / FP2000 series

Ordering Information
NC2011
NE2011

ARCNET RS 485 network card with single, RS 485 interface


RS 485 network extension board

NC2011

Analogue Adressable Fire Panels


Page : 132

ARCNET network card with single optical, interface board NE 2051

NC2051

FP1200 / FP2000 series

Ordering Information
NC2051
NE2051

ARCNET network card with single optical, interface board NE 2051


Fibre optic network extension board

RS 485 network extension board

FP1200 / FP2000 series


A RS485 network extension board for the NC2011 to allow dual bus and closed ring
networks

Ordering Information
NE2011

RS 485 network extension board

NE2011

Analogue Adressable Fire Panels


Page : 133

Fibre optic network extension board

FP1200 / FP2000 series


An extension board for the NC2051 to allow a fibre optic ring bus

Ordering Information
NE2051

Fibre optic network extension board

NE2051

Analogue Adressable Fire Panels


Page : 134

FRL700

LCD repeater

FP1200 / FP2000 series


A LON 700 LCD repeater for the FP1200 / FP2000 fire panels. Up to 15 repeater
panels may be connected to the fire panel using the LON2000 interface board. The
repeater is also available as a fire brigade panel for Dutch and Scandinavian norms.
Specifications

Dimensions mm (L x W x D)
Weight
Operating temp C
Operating voltage Vdc
Current consumption
max quiesent mA

240x320x60
1.5 kg
-5C - +40
15 - 30
100

Bus Connection
FP1200/FP2000 (with LON2000)
Bus Cable
Total number of repeaters

***
Cat 5

FP1200/FP2000

15

FP700

***

Ordering Information
FRL700
FBP70006
FBP70005
FBP70007
FBP70001
LON2000

LCD repeater
Fire brigade panel Swedish (SS3654)
Fire brigade panel Norwegian (SS3654)
Fire brigade panel Danish (SS3654)
Fire brigade panel (NEN2535)
LON700 driver for FP1200 / FP2000

2 wire connection between fire panel and repeaters

Up to 1500 metre bus length

24 Volt power supply

Cost effective repeater solutions

Easily installed, simple operation

4 x 20 charater LCD display, common LED's, push button


control
LON700

Analogue Adressable Fire Panels


Page : 135

FR1200

LCD repeater

FP1200 / FP2000 series


A powerful LCD repeater that can be used as a local or global repeater on a FP1200 /
FP2000 network.
Specifications

Supply voltage

Min. supply current @ 24 V dc


Battery charger rating @ 27.6 V dc
Total supply rating @ 27.6 V dc
Relay rating @ 24 V dc
Weight (no batteries)
Dimensions (mm H x W x D)

230 V ac (+10/-15%)
50 Hz
50 VA
0.15 A
0.3 A
1A
2A
7.5 kg
365 x 444 x 111

Ordering Information
FR1200

LCD repeater

l
l

8 x 40 character graphic display


Arcnet network connection to FP1200/FP2000 series
firepanels

Global repeater function

Comprehensive control and display functions

Analogue Adressable Fire Panels


Page : 136

FR2000

LCD repeater with emulator functions

FR1200 / FP2000 series


A powerful LCD repeater that can be used as a local or global repeater on a FP1200 /
FP2000 fire panel network. Fire panels can be emulated from the FR2000
Specifications

Supply voltage

Min. supply current @ 24 V dc


Battery charger rating @ 27.6 V dc
Total supply rating @ 27.6 V dc
Relay rating @ 24 V dc
Weight (no batteries)
Dimensions (mm H x W x D)

230 V ac (+10/-15%)
50 Hz
50 VA
0.15 A
0.3 A
1A
2A
7.5 kg
365 x 444 x 111

Ordering Information
FR2000

LCD repeater with emulator functions

l
l

8 x 40 character graphic display


Arcnet network connection to FP1200/FP2000 series
firepanels

Global repeater function

Comprehensive control and display functions

Fire panel emulation function

Dual RS232 ports

Analogue Adressable Fire Panels


Page : 137

FR2032

Repeater/emulator 32 zones/panels

FP1200 / FP2000 series


A powerful repeater / emulator with 16 to 32 displayed fire and fault zones. The
repeater is connected on the arcnet network and can operate in a local or global
repeater mode.

Ordering Information
FR2032

Repeater/emulator 32 zones/panels

l
l

8 x 40 character graphic display


Arcnet network connection to FP1200/FP2000 series
firepanels

Global repeater function

Comprehensive control and display functions

16 zones fire and fault expandable to 32 zones

24 Volt operation

Emulation functions

Analogue Adressable Fire Panels


Page : 138

FR2064

Repeater/emulator 64 zones

FP1200 / FP2000 series


A powerful repeater / emulator with 16 to 64 displayed fire and fault zones. The
repeater is connected on the arcnet network, and can operate in local or global
repeater mode.

Ordering Information
FR2064

Repeater/emulator 64 zones

l
l

8 x 40 character graphic display


Arcnet network connection to FP1200/FP2000 series
firepanels

Global repeater function

Comprehensive control and display functions

Emulation function

16 to 64 zones fire and fault displayed

24 volt operation

Analogue Adressable Fire Panels


Page : 139

UN2011

ARCNET universal node

FP1200 / FP2000 series


The unversal node allows the fire panel arcnet network to extend to computer
software applications either locally, or remotely using the MOD2000.

Ordering Information
UN2011

ARCNET universal node

FP1200 / FP2000 arcnet to RS232 interface

Allows computer applications to operate on the network

230V operation

Can be extended with MOD2000 for remote operation

'Black box' operation

MOD2000

Modem kit

FP1200 / FP2000 series


An internal modem for the FP1200 / FP2000 fire panels or a UN2011 universal node.
The modem has the autonomy of the fire panel power supply, and has extended
telephone line protectection. The MOD2000 can also be used with a computer.

Ordering Information
MOD2000

Modem kit

MOD2000

For fire panel and universal node operation

Internal installation

Autonomous power supply

Analogue Adressable Fire Panels


Page : 140

PCC2000

Programming and configuration software

FP1200 / FP2000 series


Specifications

486 66 MHz
12 Mb
VGA
20 MB
MS Mouse, etc.
Windows 95
1 x RS-232
1 parallel

Processor
RAM
Display adapter
Hard disk space
Pointing device
Graphical environment
Communications ports

Ordering Information
PCC2000

Programming and configuration software

Provide communication with single fire panels and


networked fire systems, both locally or remote via modem

Windows 95 and NT compatible

For use with FP2000, FP1200

Menu driven

Full or partial up- and download

Dynamic Link Library (DLL) for third party integration

Analogue Adressable Fire Panels


Page : 141

PCM2000

Maintenance and support software with copy protection key

FP1200 / FP2000 series


Specifications

Pentium 133Mhz (or better)


32 Mb (or more)
VGA
20 MB
Bus or P/S2 Mouse
Windows 98, NT or 2000
Depending on Drivers Printer port (for key)
1 Parallel

Processor
RAM
Display Adapter
Hard Disk Space
Pointing Device
Graphical Environment
Communications ports

Ordering Information
PCM2000

Maintenance and support software with copy protection key

Provide communication with single fire panels and


networked fire systems, both locally or remote via modem

Windows 95, 98 and NT compatible

For use with FP2000, FP1200

Full panel emulation

Data retrieval

Central station

History log

Address book

Dynamic Link Library (DLL) for third party integration

Analogue Adressable Fire Panels


Page : 142

PCG-S

Graphics package with copy protection key

PCG Series
A total of 4 packages allow the graphic package to grow with the installation. The
basic version PCG-S operates with a single panel, while the PCG-N supports a
network. The PCG-CS allows for TCP/IP client server applications. Upgrades do not
require rework on the existing database, drawings, etc.
Specifications

Recommended
Pentium II 266 MHz (or better)
64 Mb (or more)
SVGA or better
200 MB
MS Mouse, Bus or P/S2
Windows NT
1 x RS-232 - Depending on drivers
1 x Parallel - Printer port (for key)

Item
Processor
RAM
Display adapter
Hard disk space
Pointing device
Graphical environment
Communication ports

Ordering Information
PCG-S
PCG-N
PCG-CS
PCG-C

Graphics package with copy protection key


Graphics package network application with copy protection key
Graphics package for client-server application with copy protection ke
Extra client for PCG-CS

Provide bi-directional communication with single fire


panels and networked fire systems, both locally and
remote via modem

Windows 2000 and NT compatible

For use with FP2000, FP1200, FP1100 and FP700

Constructed around Sybase SQL Anywhere

Large selection of icons

Visualises inputs & outputs

Information page per point

Get texts from panel

Several operator levels and passwords

Operator configurable

Multiple navigation buttons

Event logs

Basic drawing package included

Imports .bmp & .wmf drawings from virtually any package

Hardware key protected

Content
Conventional Fire Detectors

DI322I
DP331I
DT313I
KCT731
DB304
KZ705
KZ705D
EOL-ACT
KZ705R
S300
S700
DP721I
DP721T
DT713-5
DT713-7
DB702
DI650
DP652
DT654
DB860
DB861
DB806
DB650

Ionisation detector, conventional

Page : 5

Optical detector, conventional, with field exchangeable optical block

Page : 6

Temperature detector (fixed and rate-of-rise), conventional

Page : 7

KL731/DP331I Calibration Tool

Page : 8

Universal fire detector base (Aritech 300 and 1500 series)

Page : 9

Universal fire detector base with earth connection

Page : 9

Conventional fire detector base with diode

Page : 10

Active end-of-line device for use with FP400/KL700 fire panels

Page : 11

Conventional fire detector base with relay

Page : 11

Surface mount supplement for KL300 detectors

Page : 12

Surface mount accessory for KZ700/DB304 and KZ700 series bases

Page : 12

Photoelectric smoke detector with remote alarm LED output

Page : 15

Photoelectric smoke and heat detector head with remote alarmLED output

Page : 15

57 C fixed and rate-of-rise heat detector

Page : 16

70 C fixed and R.O.R. heat detector

Page : 17

10 cm diameter base - 6 terminals

Page : 18

Ionisation smoke detector

Page : 21

Optical smoke detector

Page : 22

Heat detector, R.O.R., 57 C A1R

Page : 23

Standard Base

Page : 24

Backplate for Ingress Protection 860-950

Page : 24

Conduit box for 860 / 950 series bases

Page : 25

650 series relay base

Page : 25

Analogue Adressable Fire Detectors

DI1552
DP1561
DP1551T
DT1553
PG700
KZ705I
KZ705AS
KZ705IAS
KAL410
KAL414/4
KAL426
KAL430
KAL434/4
KAL440
KAL450
KAL460
KAL470
KAL490
DP2051
DP2061
DP2071
DT2053

Ionisation Sensor

Page : 29

Optical Sensor with field exchangeable optical block

Page : 30

Dual Sensor (Optical/Heat)

Page : 31

Heat Sensor

Page : 32

Fire sensor programmer

Page : 33

Analogue fire detector base with isolator

Page : 34

Analogue fire detector base with sounder

Page : 35

Analogue fire detector base with isolator and sounder

Page : 36

Conventional Zone Monitor Unit - 1 Zone

Page : 37

Conventional Zone Monitor Unit - 4 Zones

Page : 38

Extinguishing Control Module

Page : 39

Relay Module - 1 Relay

Page : 40

Relay Module - 4 Relays

Page : 41

Supervised Relay Module

Page : 42

Addressable Manual Call Point

Page : 43

Digital Input Module

Page : 44

Isolator Module

Page : 45

Retention Module - 1 Input / 1 Output

Page : 46

Optical Sensor

Page : 49

Optical Sensor with remote LED output

Page : 50

Optical Sensor with 7-segment display and remote LED output

Page : 51

Heat Sensor

Page : 52

DT2063
DT2073
DB2001
DB2002
DB2016
IU2016
DB2003
DM2000
DM2000E
IO2014
IU2050
IU2055
GBX2000
IU2080
FD2705R
AS2015
DI950
DP951
DT952
DM960
DI970
DP971
DT972
DM970
PT971
GBX70
II950
II952
II955
IO950
IO955
IO956
IU950
AS950
AS955
FD950
DB950
DB951
DB961
DB970
IU980

Heat Sensor with Remote LED Output

Page : 52

Heat Sensor with 7-segment Display and Remote LED Output

Page : 53

Standard Base 10 cm, 2 Terminals

Page : 54

Standard Base 4 Terminals

Page : 54

Isolating base

Page : 55

Loop Isolator

Page : 55

Base for the IU2016 isolator

Page : 56

Manual call point, flying leads

Page : 57

Manual call point - Red IP67 waterproof, including backbox

Page : 58

Input Output unit

Page : 59

Single Input Module

Page : 60

Conventional Zone Monitor

Page : 61

Galvanic barrier

Page : 61

Indicating Circuit Controller

Page : 62

2000 series addressable reflective beam smoke detector; 5 - 50m

Page : 63

2000 series loop powered sounder

Page : 64

Analogue addressable ionisation sensor

Page : 67

Optical sensor

Page : 67

Analogue addressable temperature sensor

Page : 68

950 series analogue addressable manual callpoint

Page : 68

Intrinsic safe analogue addressable ionisation detector

Page : 69

Intrinsic safe optical detector

Page : 69

Intrinsic safe heat detector

Page : 70

Intrinsic safe manual call point

Page : 70

Intrinsic safe protocol translator

Page : 71

Galvanic barrier (single channel)

Page : 71

950 series mini switch monitor unit

Page : 72

950 series switch monitor unit - surface mount

Page : 72

950 series zone monitor unit - surface mount

Page : 73

950 series single channel IO - surface mount

Page : 73

950 series output unit - surface mount

Page : 74

950 series sounder circuit controller - surface mount

Page : 74

950 series loop isolator

Page : 75

950 series loop powered sounder

Page : 76

950 series high output loop powered sounder

Page : 77

950 series loop-powered beam detector

Page : 78

950 series standard base

Page : 79

Base for IU 950

Page : 79

Isolating base (20 devices)

Page : 80

Detector base for 970 series intrinsic safe sensors

Page : 80

Coded cards, addresses 1 - 18

Page : 81

Conventional Fire Panels

FP202
FP204
FP206
FP402
FP408

Conventional fire alarm panel with 2 zones

Page : 85

Conventional fire alarm panel with 4 zones

Page : 86

Conventional fire alarm panel with 6 zones

Page : 87

Conventional fire alarm panel with 2 zones

Page : 91

Conventional fire alarm panel with 8 zones

Page : 92

FP412
FP416
RB404
SB404
FEC403
FEC406
FP604
ZI602
RC606
FP708
FR708
ZE708
ZI708
FM740
OCB724
RB708
SOB708
FB708
NC700
PS700

Conventional fire alarm panel with 12 zones

Page : 93

Conventional fire alarm panel with 16 zones

Page : 94

Relay module, 4 potential free relays for NK700/Fx400 fire panels

Page : 95

Relay module, 4 supervised relays for NK700/Fx400 fire panels

Page : 96

Conventional fire detection and extinguishing control panel with 3 zones including 1 extinguishing zone

Page : 97

Conventional extinguishing control panel with 6 zones

Page : 98

4-zone Conventional Fire Panel

Page : 101

Two zone extension board, including 6 outputs

Page : 102

Set of 6 bi-stable magnetic latch relays

Page : 102

Fire panel equipped with 8 zones

Page : 105

Repeater 8 zones, 24 VDC input

Page : 106

8 zone indicator LED extension board fire/fault

Page : 107

8 zone input extension board

Page : 107

Synoptic driver for 80 LEDs and common signals

Page : 108

LON700 output board with 24 open collector outputs

Page : 108

LON700 output board with 8 relays

Page : 109

LON700 output board with 8 supervised outputs

Page : 109

FP700 black box with 7 slot card cage

Page : 110

LON 700 interface board

Page : 111

Plug-in power supply 3.5 A

Page : 111

Analogue Adressable Fire Panels

FP1501
Analogue addressable fire detection panel - 1 loop
FP1502
Analogue addressable fire detection panel - 2 loops
NC785
RS485 Expansion kit for KSA701/FP1500 fire panels
FR1500
Analogue addressable LCD Repeater/Emulator*
MODGSM
GSM Modem for Kilsen Fire Panels
PCG-Graphic102 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-2 loops)
PCG-Graphic105 Graphic Software for KSA700/FP1500 Fire Systems (1 panel-5 loops)
PCG-GraphicNW Graphic Software for KSA700/FP1500 Fire Systems (multi-panel)
FP1216EN
Analogue panel, 2- 4 loop, 16 zones
FP2416
Analogue adressable fire panel - 2 to 4 loops. 16 zones
FP2432
Analogue addressable panel - 2 to 4 loops, 16 to 32 zones
FP2864
Analogue addressable fire panel - 2 to 8 loops. 16 - 64 zones
FB2400
Analogue addressable fire panel - 2 to 4 loops, 'black box'
LC2002
2-loop extension board for FP1200 / FP2000 fire panels
ZE2016
16-zone LED extension fire and fault LED
LON2000
LON700 driver for FP1200 / FP2000
NC2011
ARCNET RS 485 network card with single, RS 485 interface
NC2051
ARCNET network card with single optical, interface board NE 2051
NE2011
RS 485 network extension board
NE2051
Fibre optic network extension board
FRL700
LCD repeater
FR1200
LCD repeater
FR2000
LCD repeater with emulator functions
FR2032
Repeater/emulator 32 zones/panels
FR2064
Repeater/emulator 64 zones
UN2011
ARCNET universal node

Page : 115
Page : 116
Page : 117
Page : 118
Page : 119
Page : 120
Page : 121
Page : 122
Page : 125
Page : 126
Page : 127
Page : 128
Page : 129
Page : 130
Page : 130
Page : 131
Page : 131
Page : 132
Page : 132
Page : 133
Page : 134
Page : 135
Page : 136
Page : 137
Page : 138
Page : 139

MOD2000
PCC2000
PCM2000
PCG-S

Modem kit

Page : 139

Programming and configuration software

Page : 140

Maintenance and support software with copy protection key

Page : 141

Graphics package with copy protection key

Page : 142