Beruflich Dokumente
Kultur Dokumente
Catalog
North America
Product Portfolio
Contents
Hazardous Location
Heavy Duty Connectors
Non-Incendive Barriers
MC6-Current Limiter
10
12
14
16
18
20
23
24
Accessories
27
28
30
ACT20X Overview
33
36
38
Temperature Transducer
40
42
44
46
Solenoid Driver
50
ACT20M Overview
54
Signal Splitter
56
Signal Converter
58
Signal Isolator
59
60
Passive Isolator
61
63
64
66
Accessories
67
MICROSERIES Overview
68
Supply Isolator
70
Signal Isolator/Converter
72
75
WAVESERIES
76
76
80
82
84
86
Displays
87
88
89
90
93
95
Power Supplies
Industrial Ethernet
96
96
98
100
102
INSTAPOWER
103
PRO-H Series
104
connectPower
108
116
MTL Overview
124
SD Series
126
SLP Series
133
MA15 Series
134
TP48 Series
135
136
Switches Overview
138
140
Unmanaged Switches
144
Managed Switches
148
Media Converter
158
Serial/Ethernet Converter
160
SFP Modules
162
Accessories
163
Product Overview
164
Application Notes
167
168
171
Multi-I/O Units
176
181
186
Wireless Gateways
190
195
Specialty Enclosures
202
203
205
Accessories
Accessories
Antennas
208
Cables
220
WLAN Antennas
221
Cables
223
Hardware
224
227
Catalog 5:
Enclosures and Cable Glands
Catalog 2:
PCB Terminals and Connectors
Catalog 6:
Tools
Catalog 3:
RockStar Heavy Duty Connectors
Catalog 7:
Marking Systems
Catalog 4.1:
Analog Signal Conditioning
Catalog 8:
Sensor Actuator Interface
Catalog 4.2:
Relays and Optocouplers
Catalog 9:
Industrial Ethernet
Catalog 4.3:
Power Delivery
Catalog 10:
Industrial Connectivity
Catalog 4.4:
Surge Protection
Catalog 11:
Circuit and Surge Protection
Catalog 4.5:
Interface Units and PLC Solutions
Catalog 12:
Wireless I/O and Ethernet Connectivity
P-Series (Push-in)
I-Series (IDC)
Power Distribution
Blocks and Fuse Blocks
Inserts
Modular System
Housings IP65 and IP68
Cable Glands
Mechanical Relays
Solid-State (opto) Relays
Power Solid-State Relays
Multifunction Relays and Timers
Power Supplies
UPS control units/battery back up units
AC outlet DIN-Rail Mountable Receptacles
Interface Units
PLC Interfaces H-, R- and S-System
Byte Precabling Solution
Enclosures
Cable Glands
Cabtite (Cable Entry System)
Cutting
Stripping
Crimping
Screwdrivers
Automatic Machines
Ferrules
Terminal Markers
Wire and Cable Markers
Device and Equipment Markers
Printing Systems and Software
Unmanaged Switches
Managed Switches
Routers
Media Converters
JACKPAC IP67
SteadyTEC
IE Connectors
Accessories
Circuit Breakers
Overvoltage Protection
AC Receptacles
GFCI Outlets
Introduction
High quality
Housing made from high-grade
tin-plated aluminium.
Introduction
Sturdy
Sturdy spiral spring contacts ensure a long-term,
reliable electrical connection.
Color coded
Simplified assignment using color-coded inserts
and caps.
Weidmuller Heat Trace Connector for the process and oil industry
Weidmuller presents the new and innovative Heat Trace
Connector for use in the process industry, and applications
within the harsh outdoor environments in the oil industry.
Our Heat Trace Connector is designed to connect heat trace
MI cables securely, reliably and efficiently.
Product advantages are:
Coaxial connector design with 360 degree coil spring
interconnects approved for MIL spec applications
Redundant sealing system providing IP67 protection class
Vibration and corrosion proof clamping yoke elements as
found in standard Weidmuller connectivity products
Integrated grounding system
Corrosion and impact resistant single piece housing
Standard tooling installation and operation: flat blade
screwdriver only, no crimp tool required
CSA Class1 Division2/Zone2 approval, T6 temperature
code, -50C to +60C
Female HT Connector
Male HT Connector
HDC HTC M 3/4
HDC HTC M 3/4 C/W 3/4 TO 1/2 ADAPTER
Part No.
1023890000
1023890050
HDC HTC F 3/4
HDC HTC F 3/4 C/W 3/4 TO 1/2 ADAPTER
Part No.
1023880000
1023880050
Technical Data
Electrical Rated Data
Contacts
2-pole (L1, L2) + PE (ground)
Ratings
35 ampere, 600 V AC, 50 Hz / 60 Hz
Wire
Harmonized
2,5 mm2 10 mm2
AWG
8 14 AWG
Torque
1.2 Nm (for the screw clamps and securing screws)
Other Characteristics
Clamping Body
Aluminium Tin-Plated
Contacts
Brass silver-plated
Inserts
Polyamide (UL94-V0)
Gasket FVMQ
End Cap Threads
3/4 NPT-F (female thread)
Torque
90.4Nm maximum (for the 3/4 NPT end)
Number of Mating Cycles
25 typical
Environmental Conditions
Enclosure Ratings
Type 6, IP67
Approvals
CSA Class I, Division 2, Groups A,B,C,D, T6, Tamb 50 C to +60 C, Type 6
Class 1, Zone 2, Ex nA, IIC, T6, Tamb 50 C to +60 C, IP67
GOST / VDE / UL in preparation
Accessories
ADAP EX 3/4NPT-1/2NPT C1D2
HDC HTC Mounting
VG NPT 3/4 Eex-eMS
Screwdriver non-insulated (not shown)
Screwdriver insulated (not shown)
Description
Material Properties
3/4 to 1/2 reducer
Copper-free aluminum
Mounting frame
Stainless Steel
Ex cable gland IP68 - 5 bar
Brass, nickel plated
SD 0.8x4.0x100
SDI 0.8x4.0x100
Part No.
7940034662
1049370000
1778150000
9008340000
9008400000
Ordering Data
/ TS 32/
Part No.
9916290000
MC6-Current Limiter
10
MC6-Current Limiter
MC6-Current Limiter
Technical Data
Specifications:
Voltage drop across device @ 20mA
Maximum current in a short circuit condition
Response time
Optocoupler output
Voltage
Current
Status LED
Operating Temperature
Storage Temperature
Wire Size
2.5Vdc max.
24mA
1ms
24V 20%
50mA max.
red LED (on indicates fault)
0 to +50C
-20 to +70C
22 - 12 AWG
Ordering Data
Part No.
9918010000
Block Diagram
Dimensions
9.5mm
89mm
CURRENT
DETECT/LIMIT
24V
Tx+
CAT. NO:
991801
MC6 C UR R E NT
LOOP LIMITE R
68mm
991801
A0
Tx-
TX+
TX-
COM
24V
AO
R
COM
ALM
I LIMIT
ALM
Connection Diagram
-
24V
AO
ALM
PLC
Analog
Input
Tx+
IMAX
TxCOM
P/S +
24Vdc
IMAX= 25mA
in all fault
conditions
PLC
Digital
Input
11
picoPak MC5O
picoPak MC5O
Solenoid Driver
The picoPak MC5O is a compact DC solid state relay
designed specifically for 24Vdc solenoid applications. The
extra low on-state resistance allows for a high current rating
in a package just 6mm wide.
Features:
Ultra compact 6mm housing
10A @ 5-34Vdc resistive, 6A inductive switch
Combifoot mounting: TS32 & TS35 DIN-rails
4000V isolation
LED status indication
Input diode protection
Load EMF protected
CE marked
CSA certified, Class 1 Division 2, Groups A, B, C, D
12
picoPak MC5O
picoPak MC5O
Technical Data
Rated Data
Input
Input voltage range
Nominal Operating current (typical)
Output
Output resistance (on state)
Nominal switching voltage
Max. Continuous current
Operate time (at nom. voltage)
Release time (at nom. voltage)
Max. operating speed (50% mark space ratio)
Operating temperature range
General
24Vdc
11.5 to 28Vdc
5.0mA @ 24Vdc
high side MOSFET switch (sourcing)
less than 10m
5 to 34Vdc
10A resistive, 6A inductive
1mS approx.
1mS max.
50Hz (3000 operations per minute)
-40...+60 C
Isolation
surge strength
Dimensions
terminal width
width across rail
Height on rail TS32 / TS35 x 7.5 / TS35 x 15
Conductor size
solid
flexible
Fuse/Circuit Breakers (recommended)
EMC
Installation
Cleaning
Approvals
4000V
6mm
76mm
68mm / 63mm / 70.5mm
0.5...4.0mm (24-12AWG)
0.5...2.5mm (24-14AWG)
20A (65V) Slow Blow, breaking capacity 150A
EN50081-1, EN50082-2
To be installed and maintained by qualified personnel as per instructions,
or module safety may be compromised.
Designed for IEC664 Installation Category II use.
Wipe only with a damp cloth moistened with water (de-energise before cleaning).
CE marked, CSA certified, Class 1 Division 2, Groups A, B, C, D
Ordering Data
Type
picoPak MC5O
End Plate AP
End Brackets EW (for TS35)/EWK (for TS32)
Cross connection insulated
2 pole
3 pole
4 pole
Cross connection uninsulated 75 pole
straight
angled
Insulation profile 75 pole
Part No.
7901690001
C9039986
0383560000 /
0206160000
0482700000
0482800000
0482900000
0535200000
0526400000
0526700000
Power
Supply
MC5O
Output
5-34VDC
out
Input
24V
V+
Load
0V
0V
13
WaveSeries MPI-Opto
High Speed Optocoupler
The MPI-Opto offers isolation and signal level conversion for
discrete signals at frequencies up to 50KHz.
It also provides 2 isolated outputs making it ideal for driving
local displays and a PLC or DCS simultaneously. The input
can be 5Vdc or 12-24Vdc while the outputs are rated
5-28Vdc @ 50mA.
The input of the MPI-Opto can be provided by a proximity
switch, photoelectric sensor or turbine flowmeter and can
be either sinking or sourcing. Each output channel provides
inverted and non-inverted signals. Applications include
NPN-PNP conversion, signal inverter, level conversion, signal
splitter and more.
Up to 50kHz switching frequency
1 input and 2 isolated outputs
5V and 12-28V inputs
Can be used with sinking or sourcing sensors
The innovative Wavebox housing is compact and uses
plug-and-socket connections
CSA Class 1 Division 2 certified
14
MPI-Opto
4
8
5
6
9
7
10
11
12
3
OUTPUTS: SINK OR SOURCE 50mA MAX.
Technical Data
Terminal Numbering
1
2
3
4
5
6
7
8
9
10
11
Input
On-state voltage
TTL input
3.2-5Vdc
12-24V input
10-28Vdc
Off-state voltage
TTL input
0-0.8Vdc
12-24Vdc input
0-3Vdc
Current
@5V
4mA on-state
@12Vdc
4mA on-state
@24Vdc
8mA on-state
Output
Voltage 5-28Vdc
Current
50mA max. per output (sink or source)
Low-state voltage drop
<1V
High state voltage supply
Vs - 1V
Max. switching frequency (ON/OFF times)
50kHz (4 micro second ON, 4 micro second OFF)
General
Isolation
input-output
3000Vac RMS
output channel-to-channel
3000Vac RMS
Temperature
operating
0C to 55C
storage
-20C to + 70C
22-12AWG
Wire size
Dimensions in mm
width
17.7
length 90.0
height on rail TS32
n/a
height on rail TS35 x 7.5
105.2
+V2
2A
-V2
+V1
1A
-V1
V
TTL
12-24V
N/C
2B
Ordering Data
WavePak MPI-Opto
Part No.
9916080000
15
16
Innovative
Add reliability to
Finnish Delcon
a control system
Current
mA
On
Off
on
lc
De
lay
Re
y
Rela
ical
n
a
h
upler
ec
to co
trom
p
c
O
e
l
E
Voltage
DC
17
EXI-series
Solid state input relay for hazardous
locations
Non-sparking device, type of
protection nA
cULus Listed HazLoc, ATEX, IECEx,
CE (EMC and LVD)
Integrated status LED
Used with mechanical limit switches
and also with long signal cables
Mechanical Dimensions
Grey
Black
8mm
-40 to +70C
Approvals
cULus Listed file E332493
ATEX II 3 G Ex nA IIC Gc Certificate DEMKO 13 ATEX 1041005U
IECEx nA IIC Gc Certificate IECEx ULD 13.00006U
CE according to LVD 2006/95/EC and EMC 2004/108/EC for the relays
18
Description
Input Plug-in Relay
12 VDC
Control voltage
(Typ. Turn-on Nom.)
7.5 - 14VDC
Load current
range
(Min. - Max.)
0 - 50 mA
Load voltage
(Min. - Nom.)
0 - 28 VDC
EXI 24CH
16 - 28VDC
0 - 50 mA
0 - 28 VD
EXI 24CHF
16 - 28VDC
0 - 50 mA
0 - 28 VDC
EXI 24CHL
16 - 28VDC
0 - 50 mA
0 - 28 VDC
16 - 24VAC
0 - 50 mA
0 - 28 VDC
EXI 25CH
EXI 48CH
36 - 48VDC
0 - 50 mA
0 - 28 VDC
EXI 49CH
35 - 48VAC
0 - 50 mA
0 - 28 VDC
EXI 120CH
80 - 120VAC
0 - 50 mA
0 - 28 VDC
EXI 120CHI
80 - 120VAC
0 - 100 mA
0 - 28 VDC
80 - 120VAC
0 - 50 mA
0 - 28 VDC
0 - 50 mA
0 - 28 VDC
EXI 120CHP
EXI 125CH
80 - 120VDC
EXI 230CH
170 - 230VAC
0 - 50 mA
0 - 28 VDC
EXI 230CHI
170 - 230VAC
0 - 100 mA
0 - 28 VDC
170 - 230VAC
EXI 230CHR
170 - 230VAC
EXI 250CH
170 - 250VDC
EXI 230CHP
0 - 50 mA
0 - 28 VDC
0 - 28 VDC
0 - 28 VDC
19
EXO-series
DIN-rail solid state output relay for
hazardous locations
Non-sparking device, type of
protection nA
cULus Listed HazLoc, ATEX, IECEx,
CE (EMC and LVD)
Integrated status LED
For high currents with resistive and
slightly inductive loads
Derating when switching
inductive loads
This relay is meant for resistive and
slightly inductive loads. A back-emf
clamping diode with the load must
be used when switching DC inductive
loads. When controlling inductive
AC loads, there is no need to use
extra protection elements such as a
RC circuit or snubbers with the load.
The surge current is not allowed to
exceed the specification. For reasons
of heat dissipation, when the load will
be switched frequently, the average
current over a reasonable time should
not exceed the specification for
continuous operation.
Mechanical Dimensions
Fusing
To protect relay against short circuit
and overload a fast fuse with the
correct rating for the load and the
capacity of the relay should be chosen.
Note that when overload current is not
large, it is possible that the fuse will
not protect the relay because of the
tolerance on the fuse rating.
Hazardous area installation
The relay shall be installed in
accordance with this specification. The
relay shall be installed within a suitable
certified enclosure providing protection
from impact, light, solid foreign objects
and water ingress to a level of at least
IP54. The relays shall be derated in
accordance with the relay specification.
The relay can be assembled to standard
35 mm DIN-rail. Use proper tool size
to tighten the screws. Over-torqueing
may cause screw terminal breakage.
Use 60/75 C copper wire only. Do not
make connections or disconnections
while circuit is live unless area is known
to be non-hazardous. The relay shall
only be installed to mounting sockets
MOS1GNEX, MOS1CCNEX and
MOS1TNEX. Fixing with the captive
screw. The recommended installation is
to the horizontal rail for better cooling of
the relays.
20
Grey
Black
8mm
-40 to +70C
Approvals
cULus Listed file E332493
ATEX II 3 G Ex nA IIC Gc Certificate DEMKO 13 ATEX 1041005U
IECEx nA IIC Gc Certificate IECEx ULD 13.00006U
CE according to LVD 2006/95/EC and EMC 2004/108/EC for the relays
Description
Output Plug-in Relay
5 VDC/0...60 VDC
3A
Control voltage
(Typ. Turn-on
- Nom.)
2.7 - 5 VDC
Load current
range
(Min. - Max.)
0 - 3 ADC
(15A for 10ms)
EXO 5CHA
2.7 - 5 VDC
0 - 1.8 ADC
(12A for 10ms)
EXO 5CHX
2.7 - 5 VDC
0 - 10 ADC
(6.3 with socket)
(80A for 10ms)
EXO 5IHA
2.7 - 5 VDC
0 - 1.2A AC - DC
(8A for 10ms)
EXO 5TH
2.7 - 5 VDC
0 - 3 AAC
(90A for 20ms)
EXO 12CH
8 - 14 VDC
0 - 3 ADC
(15A for 10ms)
EXO 12CHA
8 - 14 VDC
0 - 1.8 ADC
(12A for 10ms)
EXO 12CHX
8 - 14 VDC
0 - 10 ADC
(6.3 with socket)
(80A for 10ms)
EXO 12TH
8 - 14 VDC
0 - 3 AAC
(90A for 20ms)
EXO 24CH
16 - 28 VDC
0 - 3 ADC
(15A for 10ms)
EXO 24CHA
16 - 28 VDC
0 - 1.8 ADC
(12A for 10ms)
EXO 24CHA4
16 - 28 VDC
0 - 4 ADC
(20A for 10ms)
EXO 24CHX
16 - 28 VDC
0 - 10 ADC
(6.3 with socket)
(80A for 10ms)
EXO 24IHA
16 - 28 VDC
0 - 1.2A AC - DC
(8A for 10ms)
EXO 24TH
0 - 3 AAC
(90A for 20ms)
Load voltage
(Min. - Nom.)
0 - 60 VDC
21
Description
Output Plug-in Relay
24 VDC/0...240 VAC
3 A, Low Leakage
Control voltage
(Typ. Turn-on Nom.)
16 - 28 VDC
Load current
range
(Min. - Max.)
0 - 3 AAC
(90A for 20ms)
Load voltage
(Min. - Nom.)
0 - 240 VAC
EXO 48CHA
30 - 48 VDC
0 - 1.8 ADC
(12A for 10ms)
0 - 250 VDC
EXO 48CHA4
30 - 48 VDC
0 - 4 ADC
(20A for 10ms)
0 - 250 VDC
EXO 48CHX
30 - 48 VDC
0 - 10 ADC
(6.3 with socket)
(80A for 10ms)
0 - 28 VDC
EXO 120CHA
80 - 120 VDC
0 - 1.8 ADC
(12A for 10ms)
0 - 250 VDC
EXO 120CHA4
80 - 120 VDC
0 - 4 ADC
(20A for 10ms)
0 - 250 VDC
EXO 220CHA
0 - 1.8 ADC
(12A for 10ms)
0 - 250 VDC
EXO 220CHA4
0 - 4 ADC
(20A for 10ms)
0 - 250 VDC
EXO P120TH
80 - 120 VAC
0 - 3 AAC
(90A for 20ms)
0 - 240 VAC
EXO P230TH
0 - 1.5 AAC
(90A for 20ms)
0 - 240 VAC
22
Description
Output DIN-rail Relay
5 VDC/0...24 VDC
10 A
Control voltage
(Typ. Turn-on Nom.)
2.7 - 5 VDC
Load current
range
(Min. - Max.)
0 - 10 ADC
(80A for 10ms)
Load voltage
(Min. - Nom.)
0 - 28 VDC
EXO 12CHXSN
8 - 14 VDC
0 - 10 ADC
(80A for 10ms)
0 - 28 VDC
EXO 24CHXSN
16 - 28 VDC
0 - 10 ADC
(80A for 10ms)
0 - 28 VDC
EXO 48CHXSN
30 - 48 VDC
0 - 10 ADC
(80A for 10ms)
0 - 28 VDC
MIS-series
Mounting sockets for hazardous
locations with tension spring or
screw clamp terminals
MIS1xxxx for EXI-relays (input)
MOS1xxxx for EXO-relays (output)
cULus Listed HazLoc, ATEX, IECEx,
CE (LVD)
Connection Diagrams
Connections for MIS 1CCNEX
Logic side
Field side
Mechanical Dimensions
See table below
for dimensions
Description
DIN-rail Socket for
EXI Input Relay
Connection type
Tension spring clamp
MIS 1GNEX
MIS 1TNEX
DIN-rail Socket
for EXI Input Relay,
Test Holes 2.3 mm
DIN-rail Socket for
EXO Output Relay
MOS 1CCNEX
MOS 1GNEX
MOS 1TNEX
Load current
range
(Min. - Max.)
0 - 6.3 A
Load voltage
range
(Min. / Nom.)
0 - 250
VAC/VDC
Dimensions (mm)
12.8 W x 80.6 L x 32.5 H
(74.0 H with Relay)
0 - 6.3 A
0 - 250
VAC/VDC
0 - 6.3 A
0 - 250
VAC/VDC
0 - 6.3 A
0 - 250
VAC/VDC
0 - 6.3 A
0 - 250
VAC/VDC
0 - 6.3 A
0 - 250
VAC/VDC
23
24
1 change-over contact
AC/DC/UC coil
Technical Data
11
14
A2
(12 V DC)
12
A1
11
14
(24 V DC)
A2
12
A1
11
14
(24 V UC)
12
A2
A1
Output
max. switching voltage AC1/Continuous current
min. switching power
Response time / Drop-out time
Contact base material
Mechanical endurance
max. switching frequency at rated load
Rated data
Status indicator/Free wheel diode
Reverse pol. prot
Ambient temperature (operational)
Storage temperature
Humidity
Insulation coordination (EN 50178)
Standards
Rated voltage
Impulse withstand voltage
Clearance and creepage distances for control/load side
Surge category
Pollution severity
Protective separation to VDE 0106 part 101
Dimensions
Clamping range (rating- / min. / max.) (mm2)
Length x width x height (mm)
Approvals
250 V/6 A
12 V / 100 mA
6.2ms/3.9ms
AgSnO
20*106 switching cycles
0.1 Hz
green LED/Yes
available
-25C+50 C
-40C+60 C
40C/93% RH, no condensation
EN 50178
300 V
4 kV
5.5 mm
III
2
Yes
Screw connection
2.5 / 0.5 / 4
93 / 6.1 / 92
CE; cULus; C1D2
Ordering Data
Input
Rated voltage
Rated current AC
Rated current DC
Power rating
AC Response/dropout Volt
DC Response/dropout Volt
AC pickup/dropout current
DC pickup/dropout current
12 VDC 1CO
12 V DC 20%
24 V DC 1CO
24 V DC 20 %
17 mA
210 mW
6.6mA
160 mW
6.4V/ 2.5V
15.4V/6.5V
Type
MRS 12Vdc 1CO C1D2
8.4mA/2.4mA
Screw connection
24 V UC 1CO
24 V UC 10 %
11 mA
6.4 mA
154 mW
15.8V/7V
15.8V/7V
3.6mA/1.3mA
3.6mA/1.3mA
4mA/1.2mA
Part No.
8967340000**
Type
Part No.
RSS113012 12Vdc-Rel1U 4061610000
Type
MRS 24Vdc 1CO C1D2
Part No.
8967350000
Type
Part No.
RSS113024 24Vdc-Rel1U 4060120000
Type
MRS 24Vuc 1CO C1D2
Part No.
8967360000
Type
Part No.
RSS113024 24Vdc-Rel1U 4060120000
25
Relays - MICROSERIES
120 VAC RC version:
RC circuit at the input guarantees
safe switching thresholds,
e.g. for leakage currents on the control side
1 change-over contact
AC/DC/UC coil
Technical Data
11
(120 V AC RC)
14
A2
12
A1
11
(230 V UC)
14
12
A2
A1
Output
max. switching voltage AC1/Continuous current
min. switching power
Response time / Drop-out time
Contact base material
Mechanical endurance
max. switching frequency at rated load
Rated data
Status indicator/Free wheel diode
Reverse pol. prot
Ambient temperature (operational)
Storage temperature
Humidity
Insulation coordination (EN 50178)
Standards
Rated voltage
Impulse withstand voltage
Clearance and creepage distances for control/load side
Surge category
Pollution severity
Protective separation to VDE 0106 part 101
Dimensions
Clamping range (rating- / min. / max.) (mm2)
Length x width x height (mm)
Approvals
250 V/6 A
12 V / 100 mA
6.2ms/3.9ms
AgSnO
20*106 switching cycles
0.1 Hz
green LED/Yes
available
-25 C+50 C
-40 C+60 C
40C/93% RH, no condensation
EN 50178
300 V
4 kV
5.5 mm
III
2
Yes
Screw connection
2.5 / 0.5 / 4
93 / 6.1 / 92
CE; cULus; C1D2
Ordering Data
Input
Rated voltage
Rated current AC
Rated current DC
Power rating
AC Response/dropout Volt
DC Response/dropout Volt
AC pickup/dropout current
DC pickup/dropout current
Relay with socket
Spare relay (pluggable)*
*Spare relays do not feature individual C1D2 approval.
26
120 V AC 1CO RC
120 V AC + 10% / -15%
7 mA
230 V UC 1CO
230 V UC +10% / -15%
3.5 mA
2.9 mA
0.8 VA / 660 mW
146 V / 124 V
155 V / 115 V
1.9 mA / 1.5 mA
1.9 mA / 1.0 mA
0.84VA
79 V / 65 V
4.5 mA / 3.7 mA
Screw connection
Type
MRS 120VUC 1C0 RC C1D2
Part No.
8967370000
Type
MRS 230VUC 1CO C1D2
Part No.
8967380000
Type
Part No.
4061630000
Type
RSS113060 60Vdc-Rel1U
Part No.
4061630000
RSS1130600 60Vdc-Rel1U
Accessories
Plug-in cross-connection
Technical Data
No. of poles
Qty
Part No.
2
3
4
10
20
60
60
60
20
20
1758250000
1762630000
1762620000
1758260000
1909020000
2
3
4
10
20
60
60
60
20
20
1793950000
1793980000
1794010000
1794040000
1909150000
2
3
4
10
20
60
60
60
20
20
1793960000
1793990000
1794020000
1794050000
1909100000
2
3
4
10
20
60
60
60
20
20
1793970000
1794000000
1794030000
1794060000
1909120000
Other accessories
Screw
Conductor connection
Solid H07V-U
mm2
0.5 4.0
Stranded H07V-K
mm2
0.5 2.5
f with wire end ferrules to DIN 46228-1
mm2
0.5 1.5
f with wire end ferrules with plastic collar
mm2
0.5 1.5
Max. clamping range
mm2
0.13 4.0
Plug gauge to IEC 60947-1
size
A3
General technical data
Nominal torque
0.6
Continuous current for 2-pole cross-connection
A
10
A
10
Continuous current for multi-pole cross-connection
mm
7
Stripping length
Ingress protection class
IP 20
Housing material
Wemid
UL 94 flammability rating
V-0
Nominal current
A
6
V
250
Nominal voltage
Dimensions
Qty
Part No.
600
1609900000
Labels, Lasermark
LM MT 300 15/6 ge
484 labels/sheet
10
1686360000
Screwdriver
SD 0.6 x 3.5 x 100
10
9008330000
Screw Connection
92 mm
Type
Markers
WS 12/6
12 x 6 mm
93 mm
6.1 mm
Type
yellow
ZQV 4N / 2 GE
ZQV 4N / 3 GE
ZQV 4N / 4 GE
ZQV 4N / 10 GE
ZQV 4N / 20 GE
red
ZQV 4N / 2 RT
ZQV 4N / 3 RT
ZQV 4N / 4 RT
ZQV 4N / 10 RT
ZQV 4N / 20 RT
blue
ZQV 4N / 2 BL
ZQV 4N / 3 BL
ZQV 4N / 4 BL
ZQV 4N / 10 BL
ZQV 4N / 20 BL
black
ZQV 4N / 2 SW
ZQV 4N / 3 SW
ZQV 4N / 4 SW
ZQV 4N / 10 SW
ZQV 4N / 20 SW
27
picoPak I - I
4-20mA Isolator
The picoPak I-I is a very compact isolator for 4-20mA
loops. The output is loop powered. The module is perfect for
eliminating ground loops and providing increased protection
for PLC and DCS analog inputs.
Isolation is optical. This means the output load does not
effect the voltage drop across the input (the voltage drop is a
near constant at 3.5V).
Features:
Only 8mm wide
Mounts on 32mm and 35mm DIN-rails
2000V isolation
User adjustable span and zero adjustments
CSA, CE and Class 1 Div 2 approved
28
Technical Data
DC Current
4-20mA
variable, <3.5Vdc over input range
50mA
not applicable
Vs
AC or DC
N
IN+
+
4 Wire
Transmitter
+
+
DC current
4-20mA
0-500M or Rmax=[(Vs-14)/0.02]
3.6mA for input open, 24mA max. for overcurrent input
15% nominal around 4mA for calibration purposes
15% nominal around 20mA for calibration purposes
990880
24V+
+
3 Wire
Transmitter
2 Wire
Transmitter
+
IN+
IN-
IN+
18-30Vdc
Supply
OUT+
OUT-
IN-
picoPak I/I
IN+
External
Load
<500 Ohms
IN+
Input
Range
Impedance
Maximum ratings / type of protection
Field device excitation
Other input specification
Output
Range
Load
Burnout level
Zero adjustment
Span adjustment
Protection
Other output specification
Supply
Range
Consumption
General
Accuracy / Linearity
Temperature coefficient (drift)
Transmission Frequency
Response time, 90% span
Other general specification
Status LED
Isolation (# of ports)
Operating / Storage temperature
Housing (mounting)
Dimensions in mm (length x width x height)
Wire range (conductor size)
Tightening torque / insulation stripping length
Approvals
5mSec., typical
none
2000V (2 port)
0C to 50C / -20C to 70C
DK6 (TS32 and TS35)
88.4 x 9.5 (end plate included) x 78.5 max.
22-12AWG (0.5-4.0mm2)
0.4Nm / 7mm
CSA, Class 1 Divison 2, CE
Ordering Data
picoPak
Optional End plate (width)
Type
picoPakTM I-I
AP1 (1.5mm)
Note:
Part No.
9908800000
C9040396
29
WavePak
Loop Splitter
The WavePak Loop Splitter module is a 4-20mA current loop
isolator with one loop powered input and two independent,
loop powered, isolated outputs. It is ideal for interfacing
one transmitter to two devices such as a PLC and a
localindicator.
Some loop splitters are actually two single channel devices
with their inputs connected in series.This increases the
loading on the current loop. Weidmullers Loop Splitter
has a single input circuit with a near constant voltage drop
of no more than 3.5V, regardless of the output loop load.
This is accomplished through the use of optical isolation
as opposed to transformer coupling. Optical isolation also
provides higher isolation levels - 1000V in the case of the
Loop Splitter.
Features:
Loop powered
Near constant input voltage drop
Only 12.5mm wide
Mounts on 35mm DIN-rail
CSA approved, Class 1 Division 2 approved
30
Ordering Data
WavePak-I/2I
Part No.
792040 0000
Notes: The Unit should be recalibrated under the normal operating conditions (factory calibated at 24C into 250W). Inadequate ventilation
and/or multiple loop splitters (or warm adjacent modules) can affect linearity. Optimal resilts can be achieved with 1cm (1/4) space
either side of the loop splitter.
31
32
33
ACT20X Overview
34
ACT20X Overview
\
;
"
Worldwide application
Fulfils the strict standards and requirements of the process industry. Can be
used worldwide due to international
and local approvals ATEX, IECEX,
CULUS, FM, GOST and DNV.
Intelligent connection system
Pluggable, coded, with release lever.
The release lever simplifies
maintenance and allows disconnection
without damaging the cables.
Alarm function
No laborious troubleshooting. Alarm
function integrated for cable or sensor
errors. In case of failures, a diagnostic
signal is sent to the control system.
+60 C
to
20 C
Temperature transducer
Robust
Wide ambient temperature range from
20 C + 60 C.
NAMUR disconnect-switch
amplifier
35
ACT20X
Ex label
Input Signals
ATEX
II 3 G Ex nA nC IIC T4
II (1) G [Ex ia] IIC/IIB/IIA
II (1) D [Ex iaD]
IECEx
Ex nA nC IIC T4 Gc
[Ex ia Ga] IIC/IIB/IIA
[Ex ia Da] IIIC
FM
Installation in CL I DIV2 GP A-D T4
Protects Ex circuits, in compliance with
Cl. I-III ABT 1/2 GP A-G or
Cl. I Zn2 AEx/Ex nA nC [ia] IIC T4.
Output Signals
Analogue, 4...20 mA
44
14
42
43
13
41
42
12
44
41
11
43
Channel 1:
+
Tx
+
mA
mA
2-wire supply +
Current
2-wire supply
4...20 mA
+
mA
2-wire supply
4...20 mA
mA
2-wire supply +
Spannungsversorgung
und Modulstatus
Channel 2:
+
Tx
24
51
23
52
22
53
21
54
Gnd.
Supply +19,2...31,2 V DC
Module status
N.C.
Module status
Application example:
Measuring temperature with a head transmitter, signal transmission with HART
EX-Zone
Safe Zone
A.C. supply
+24 V DC
0V
2 wire HART
head transmitter
for temperature
To other isolators
Zone 0
Tank
36
ACT20X-HAI-SAO
Power
supply
PS
+24 V DC
4-20 mA / HART
input
Control system
4-20 mA / HART
output
Passive
input
channel
ACT20X
ACT20X-HAI-SAO-S / 2HAI-2SAO-S
I
I
PS
Technical Data
Input
Input current
Sensor supply
Residual ripple (current loop)
Output analog
Output current
Output signal limit
load impedance current
2-wire supply
Accuracy
Temperature coefficient
Step response time
Cut-off frequency (-3 dB)
Alarm output
Type
Nominal switching voltage
4...20 mA
28 V DC
< 7.5 mVeff
3.5 23 mA
< 28 mA
600
26 V DC
< 0.1% span
< 0.01% of span/C (TU)
5 ms
0.52.5 kHz @ 3.523 mA bi-directional HART signal
Relay, 1 NC (voltage-free)
125 V AC / 110 V DC (safe area)
32 V AC / 32 V DC (Zone 2)
0.5 A AC / 0.3 A DC (safe zone), 0.5 A AC / 1 A DC ( Zone 2)
62.5 VA / 32 W (safe area)
16 VA / 32 W (Zone 2)
Continuous current
Power rating
General Data
Supply voltage
Power consumption
Ambient temperature / Storage temperature
Insulation coordination
Insulation voltage
Rated voltage
EMC standards
Data for Ex applications (ATEX)
Voltage U0
Current I0
Power P0
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
19.2 31.2 V DC
3 W (2 channels)
-20 C...+60 C / -20 C...+85 C
2.6 kV (input / output)
300 V
DIN EN 61326
Current loop 28 V / externally 10 V
Current loop 93 mA / externally 10 mA
Current loop 0.65 W / externally 0.1 W
Screw connection
2.5 / 0.5 / 2.5
119.2 / 22.5 / 113.6
DEKRAATEX; IECEXDEK
Ordering Data
1-channel version
2-channel version
Note:
Type
ACT20X-HAI-SAO-S
ACT20X-2HAI-2SAO-S
Qty.
1
1
Part No.
8965430000
8965440000
37
ACT20X
Connection diagram:
Ex label
Ex Output signals
ATEX
II 3 G Ex nA nC IIC T4
II (1) G [Ex ia] IIC/IIB/IIA
II (1) D [Ex iaD]
IECEx
Ex nA nC IIC T4 Gc
[Ex ia Ga] IIC/IIB/IIA
[Ex ia Da] IIIC
FM
Installation in CL I DIV2 GP A-D T4
Protects Ex circuits, in compliance with
Cl. I-III ABT 1/2 GP A-G or
Cl. I Zn2 AEx/Ex nA nC [ia] IIC
Input signals
Analogue, 4...20 mA
42
43
13
41
42
12
44
41
11
43
Load
4...20 mA
Ch 2
Channel 1:
Ch1
44
14
Channel 2:
Load
4...20 mA
24
51
23
52
22
53
21
54
Gnd.
Supply +19,2...31,2 V DC
Module status
N.C.
Module status
Control
system
Safe Zone
A.C. supply
Power
supply
+
-
+24 V DC
0V
HART valve
Actuator
PS
+24 V DC
4-20 mA / HART input
EX-Zone
Actuator
Output
Control system
ACT20X-SAI-HAO
Control valve
38
ACT20X
ACT20X-SAI-HAO-S / 2SAI-2HAO-S
I
I
PS
Technical Data
Input
Input current
Voltage drop
Output analog
Output current
Output signal limit
load impedance current
2-wire supply
Residual ripple (current loop)
Accuracy
Temperature coefficient
Step response time
Cut-off frequency (-3 dB)
Alarm output
Type
Nominal switching voltage
420mA
<2V
420 mA (max. 23 mA)
< 28 mA
600
> 14.5 V @ 20 mA
< 7.5 mVeff
< 0.1% span
< 0.01% of span/C (TU)
5 ms
0.52.5 kHz @ 3.523 mA bi-directional HART signal
Relay, 1 NC (voltage-free)
125 V AC / 110 V DC (safe area)
32 V AC / 32 V DC (Zone 2)
0.5 A AC / 0.3 A DC (safe zone), 0.5 A AC / 1 A DC ( Zone 2)
62.5 VA / 32 W (safe area)
16 VA / 32 W (Zone 2)
Continuous current
Power rating
General data
Supply voltage
Power consumption
Ambient temperature / Storage temperature
Insulation coordination
Insulation voltage
Rated voltage
EMC standards
Data for Ex applications (ATEX)
Voltage U0
Current I0
Power P0
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
19.2 31.2 V DC
3 W (2 channels)
-20 C...+60 C / -20 C...+85 C
2.6 kV (input / output)
300 V
DIN EN 61326
28 V DC
93 mA
< 650 mW
Screw connection
2.5 / 0.5 / 2.5
119.2 / 22.5 / 113.6
DEKRAATEX; GOSTME25; IECEXDEK
Ordering Data
1-channel version
2-channel version
Note:
Type
ACT20X-SAI-HAO-S
ACT20X-2SAI-2HAO-S
Qty.
1
1
Part No.
8965450000
8965460000
39
ACT20X
Temperature transducer
The ACT20X-HTI-SAO temperature transducer processes temperature signals from PT100 sensors and
thermocouples originating in the Ex zone. A current signal (mA) can also be connected as the input signal. The
input is part of an intrinsically safe circuit (Zone 0). The isolated milliamp analog output is the input to the
receiver or controller in the safe area. It is available in a single-channel or double-channel version.
Ex label
Input signals
Channel 1:
Current
Analogue, 0/4...20 mA
TC
Current
Channel 2:
RTD
Connection,
wires
Output signals
RTD
Connection,
wires
44
14
42
43
13
41
42
12
44
41
11
43
2-wire supply
4...20 mA
+
mA
mA
Channel 1
2-wire supply +
2-wire supply
4...20 mA
+
mA
mA
Channel 2
2-wire supply +
51
23
52
22
53
21
54
Supply
Supply +19,2...31,2 V DC
Module status
N.C.
Module status
EX-Zone
Safe Zone
A.C. supply
+24 V DC
0V
Resistance
temperature sensor
To other isolators
Zone 0
Tank
ACT20X-HTI-SAO
Control system
Power
supply
PS
40
ATEX
II 3 G Ex nA nC IIC T4
II (1) G [Ex ia] IIC/IIB/IIA
II (1) D [Ex iaD]
IECEx
Ex nA nC IIC T4 Gc
[Ex ia Ga] IIC/IIB/IIA
[Ex ia Da] IIIC
FM
Installation in CL I DIV2 GP A-D T4
Protects Ex circuits, in compliance with
Cl. I-III ABT 1/2 GP A-G or
Cl. I Zn2 AEx/Ex nA nC [ia] IIC T4.
4-20 mA Output
passive
input
Input
Accuracy
Input mA
Input RTD
Pt100
Ni100
Input TC
Type B
Type E, J, K, L, N, T, U
Type R , S, W3, W5, LR
4 A
Temperature
coefficient
4 A / C
0.2 C
0.3 C
0.02 C / C
0.03 C / C
4.5 C
1 C
2 C
0.45 C / C
0.1 C / C
0.2 C / C
ACT20X
Temperature transducer
ACT20X-HTI-SAO-S / 2HTI-2SAO-S
J, I
I
J, I
I
PS
Technical Data
Type
Input
Type
Sensor supply
Temperature input range
Line resistance in measuring circuit
Input current
Input resistance, current
Output
Output current
Output signal limit
load impedance current
Influence of load resistance
Current loop output
Output current (current loop)
Load resistance
Influence of load resistance
2-wire supply
Alarm output
Type
Nominal switching voltage
Continuous current
Power rating
General data
Supply voltage
Power consumption
Tightening torque, min. / Tightening torque, max.
Ambient temperature / Storage temperature
Insulation coordination
Insulation voltage
Rated voltage
EMC standards
Data for Ex applications (ATEX)
Voltage U0
Current I0
Power P0
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
19.2 31.2 V DC
3 W (2 channels)
0.4 Nm / 0.6 Nm
-20 C...+60 C / -20 C...+85 C
2.6 kV (input / output)
300 V
DIN EN 61326
Temperaturerange
Accuracy
Metal PTC
Pt100
-200850 C
(0.15 + 0.02 x T) Class A
Pt500
-200850 C
(0.30 C + 0.005 x T) Class B
Pt1000
-200850 C
Ni50
Ni100
-600 C (0.4 + 0.007 x T)
Ni120
0180 C (0.4 + 0.028 x T)
Ni1000
TC-Type according to IEC60584-1
B
50250 C 25 K
250500 C 10 K
5001820 C 6 K
E
-200-150 C 4 K
-1501000 C 3 K
J
-200-150 C 4 K
-1501200 C 3 K
K
-200-150 C 5 K
-1501200 C 3 K
12001372 C 4 K
N
-200-150 C 6 K
-1501300 C 3 K
R
-50200 C 10 K
200..1780 C 6 K
S
-50200 C 10 K
2001780 C 6 K
T
-200-150 C 5 K
-150400 C 3 K
according to DIN43710
U
0600 C 3 C
L
0900 C 3 C
8.7 V DC
18.4 mA
40 mW
Screw connection
2.5 / 0.5 / 2.5
119.2 / 22.5 / 113.6
cULus; FMEX; GOSTME25; IECEXKEM; KEMAATEX
Ordering Data
1-channel version
2-channel version
Note:
Type
ACT20X-HTI-SAO-S
ACT20X-2HTI-2SAO-S
Qty.
1
1
Part No.
8965470000
8965480000
41
ACT20X
Connection diagram: the ACT20X-HUI-SAO universal measurement and signal isolating converter
Input signals
ATEX
II 3 G Ex nA nC IIC T4
II (1) G [Ex ia] IIC/IIB/IIA
II (1) D [Ex ia Da]
IECEx
Ex nA nC IIC T4 Gc
[Ex ia Ga] IIC/IIB/IIA
[Ex ia Da] IIIC
FM
Installation in CL I DIV2 GP A-D T4
Protects Ex circuits, in compliance with
Cl. I-III ABT 1/2 GP A-G or
Cl. I Zn2 AEx/Ex nA nC [ia] IIC
Output signals
44
14
42
43
13
41
42
12
44
41
11
43
2-wire supply
4...20 mA
+
mA
mA
2-wire supply +
Relay
N.O.
Input signals
+
Tx
Relay
Power Supply
24
51
23
52
22
53
21
54
Gnd
Supply +19,2...31,2 V DC
+
+
Module status
N.C.
Module status
EX-Zone
Safe zone
A.C. supply
+24 V DC
0V
Other devices
Positional
potentiometer
ACT20X-HUI-SAO
Valve
Control system
Power
supply
PS
42
Ex label
4-20 mA output
Passive
input
channel
Input
Accuracy
Input mA
Input Volt
Input RTD
Pt100
Ni100
Input TC
Type B
Type E, J, K, L, N, T, U
Type R , S, W3, W5, LR
4 A
20 V
Temperature
coefficient
4 A / C
2 V / C
0.2 C
0.3 C
0.02 C / C
0.03 C / C
4.5 C
1 C
2 C
0.45 C / C
0.1 C / C
0.2 C / C
ACT20X
ACT20X-HUI-SAO-S
J, I, U
I
PS
Technical Data
Type
Input
Type
Sensor supply
Temperature input range
Line resistance in measuring circuit
Input current
Input voltage
Input resistance, voltage/current
Output analog
Output current
Output signal limit
load impedance current
Influence of load resistance
Current loop output
Output current (current loop)
Load resistance
Influence of load resistance
2-wire supply
Output digital
Type
Function
Nominal switching voltage
Continuous current
Alarm output
Type
Nominal switching voltage
Relay, 1 NC (voltage-free)
125 V AC / 110 V DC (safe area)
32 V AC / 32 V DC (Zone 2)
0.5 A AC / 0.3 A DC (safe zone), 0.5 A AC / 1 A DC ( Zone 2)
Continuous current
General data
Supply voltage
Power consumption
Tightening torque, min. / Tightening torque, max.
Ambient temperature / Storage temperature
Insulation coordination
Insulation voltage
Rated voltage
EMC standards
Data for Ex applications (ATEX)
Voltage U0
Current I0
Power P0
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
19.2 31.2 V DC
3.5 W
Temperaturerange
Accuracy
Metal PTC
Pt100
-200850 C
(0.15 + 0.02 x T) Class A
Pt500
-200850 C
(0.30 C + 0.005 x T) Class B
Pt1000
-200850 C
Ni50
Ni100
-600 C (0.4 + 0.007 x T)
Ni120
0180 C (0.4 + 0.028 x T)
Ni1000
TC-Type according to IEC60584-1
B
50250 C 25 K
250500 C 10 K
5001820 C 6 K
E
-200-150 C 4 K
-1501000 C 3 K
J
-200-150 C 4 K
-1501200 C 3 K
K
-200-150 C 5 K
-1501200 C 3 K
12001372 C 4 K
N
-200-150 C 6 K
-1501300 C 3 K
R
-50200 C 10 K
200..1780 C 6 K
S
-50200 C 10 K
2001780 C 6 K
T
-200-150 C 5 K
-150400 C 3 K
according to DIN43710
U
0600 C 3 C
L
0900 C 3 C
0.4 Nm / 0.6 Nm
-20 C...+60 C / -20 C...+85 C
2.6 kV (input / output)
300 V
DIN EN 61326
8.7 V DC
18.4 mA
40 mW
Screw connection
2.5 / 0.5 / 2.5
119.2 / 22.5 / 113.6
cULus; FMEX; GOSTME25; IECEXKEM; KEMAATEX
Ordering Data
1-channel version
Note:
Type
ACT20X-HUI-SAO-S
Qty.
1
Part No.
8965490000
43
ACT20X
ATEX
II 3 G Ex nA nC IIC T4
II (1) G [Ex ia] IIC/IIB/IIA
II (1) D [Ex iaD]
IECEx
Ex nA nC IIC T4 Gc
[Ex ia Ga] IIC/IIB/IIA
[Ex ia Da] IIIC
FM
Installation in CL I DIV2 GP A-D T4
Protects Ex circuits, in compliance with
Cl. I-III ABT 1/2 GP A-G or
Cl. I Zn2 AEx/Ex nA nC [ia] IIC
Output signals
42
41
+
mA
2-wire supply
4...20 mA
mA
2-wire supply +
42
12
41
11
Input signals
Power Supply
51
+
Tx
Ex label
52
Gnd
Supply +19.2...31.2 V DC
+
+
22
21
Safe Zone
EX-Zone
Control
system
Resistance
temperature sensor
Zone 0
Tank
44
ACT20X-HUI-SAO
4-20 mA Output
Input
channel
active
Input
Accuracy
Input mA
Input Volt
Input RTD
Pt100
Ni100
Input TC
Type B
Type E, J, K, L, N, T, U
Type R , S, W3, W5, LR
4 A
20 V
Temperature
coefficient
4 A / C
2 V / C
0.2 C
0.3 C
0.02 C / C
0.03 C / C
4.5 C
1 C
2 C
0.45 C / C
0.1 C / C
0.2 C / C
ACT20X
ACT20X-HUI-SAO-LP-S
J, I, U
I
Technical Data
Input
Type
Temperature input range
Input current
Input voltage
Input resistance, voltage / Input resistance, current
Potentiometer
Resistance
Output analog
Output current
load impedance current
Residual ripple (current loop)
Accuracy
Temperature coefficient
Step response time
Cut-off frequency (-3 dB)
General data
Supply voltage
Power consumption
Tightening torque, min. / Tightening torque, max.
Ambient temperature / Storage temperature
Insulation coordination
Insulation voltage
Rated voltage
EMC standards
Data for Ex applications (ATEX)
Voltage U0
Current I0
Power P0
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
Inputs
Type
Thermocouple inputs
4 kV (input / output)
300 Veff
DIN EN 61326
5.88 V DC
82.3 mA
121 mW
Screw connection
2.5 / 0.5 / 2.5
119.2 / 12.5 / 113.6
cULus
Ordering Data
1-channel version
Note:
Type
ACT20X-HUI-SAO-LP-S
Qty.
1
Part No.
1318220000
45
ACT20X
Ex label
Input signals
NAMUR
Mechanical
switch
Channel 1:
Rs
Rp
Channel 2:
Rp
14
44
13
43
12
42
11
41
Relay
Channel 1:
N.O. or N.C.
Relay
Relay
Channel 1:
N.O. or N.C.
Relay
Power supply
Mechanical
switch
NAMUR
24
51
23
52
22
53
21
54
Gnd.
Rs
Rp
ATEX
II 3 G Ex nA nC IIC T4
II (1) G [Ex ia] IIC/IIB/IIA
II (1) D [Ex iaD]
IECEx
Ex nA nC IIC T4 Gc
[Ex ia Ga] IIC/IIB/IIA
[Ex ia Da] IIIC
FM
Installation in CL I DIV2 GP A-D T4
Protects Ex circuits, in compliance with
Cl. I-III ABT 1/2 GP A-G or
Cl. I Zn2 AEx/Ex nA nC [ia] IIC T4.
Output signals
Supply +19,2...31,2 V DC
Rp
Module status
N.C.
Module status
Application: monitoring of fill level with the ACT20X HDI-SDO-RNO (relay output)
EX-Zone
Safe Zone
A.C. supply
Control
+24 V DC
Fill level is high,
intrinsically safe
Namur or
mechanical switch
0V
PS
Other converter
Channel 1 digital output
ACT20X-2HDI-2SDO-RNO
46
Power
supply
Zone 0
Tank
ACT20X
ACT20X-HDI-SDO-RNO-S / RNC-S
ACT20X-2HDI-2SDO-RNO-S / RNC-S
PS
Ordering Data
Technical Data
Input
Sensor
Sensor supply
Resistance
Input frequency
Pulse duration
Input resistance
Trigger level low / Trigger level high
Output signal in case of wire break
Output
Type
Rated switching voltage
Continuous current
Power rating
Alarm output
Type
Nominal switching voltage
Continuous current
Power rating
General data
Supply voltage
NAMUR supply
Power consumption
Tightening torque, min. / Tightening torque, max.
Ambient temperature / Storage temperature
Insulation coordination
Insulation voltage
Rated voltage
EMC standards
Data for Ex applications (ATEX)
Voltage U0
Current I0
Power P0
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
Note:
Type
1-channel version, NO
ACT20X-HDI-SDO-RNO-S
1-channel version, NC
ACT20X-HDI-SDO-RNC-S
2-channel version, NO
ACT20X-2HDI-2SDO-RNO-S
2-channel version, NC
ACT20X-2HDI-2SDO-RNC-S
Qty.
Part No.
8965340000
8965350000
8965370000
8965380000
Relay, 2 NC (voltage-free)
250 V AC / 30 V DC (safe area)
32 V AC / 32 V DC (Zone 2)
2 A AC/DC (safe area, Zone 2 area)
500 VA / 60 W (safe area)
16 VA / 32 W (Zone 2)
Relay, 1 NC (voltage-free)
125 V AC / 110 V DC (safe area)
32 V AC / 32 V DC (Zone 2)
0.5 A AC / 0.3 A DC (safe zone), 0.5 A AC / 1 A DC ( Zone 2)
62.5 VA / 32 W (safe area)
16 VA / 32 W (Zone 2)
19.2 31.2 V DC
8 V DC / 8 mA
3 W (2 channels)
0.4 Nm / 0.6 Nm
-20 C...+60 C / -20 C...+85 C
2.6 kV (input / output)
300 V
DIN EN 61326
10.6 V DC
12 mA DC
32 W
Screw connection
2.5 / 0.5 / 2.5
119.2 / 22.5 / 113.6
cULus; FMEX; GOSTME25; IECEXKEM; KEMAATEX
47
ACT20X
Ex label
Input signals
Mechanical
switch
NAMUR
Channel 1:
Rs
Rp
ATEX
II 3 G Ex nA nC IIC T4
II (1) G [Ex ia] IIC/IIB/IIA
II (1) D [Ex iaD]
IECEx
Ex nA nC IIC T4 Gc
[Ex ia Ga] IIC/IIB/IIA
[Ex ia Da] IIIC
FM
Installation in CL I DIV2 GP A-D T4
Protects Ex circuits, in compliance with
Cl. I-III ABT 1/2 GP A-G or
Cl. I Zn2 AEx/Ex nA nC [ia] IIC T4.
Output signals
Rp
14
44
13
43
12
42
11
41
Opto +
Channel 2:
Opto
Opto +
Channel 1:
2:
Channel
NAMUR
Opto
Power Supply
Mechanical
switch
24
51
23
52
22
53
21
54
Gnd
Rs
Rp
Supply +19,2...31,2 V DC
Rp
Module status
N.C.
Module status
EX-Zone
Safe Zone
A.C. supply
Control
+24 V DC
Fill level is high,
intrinsically safe
Namur or
mechanical
switch
0V
PS
Other converter
Channel 1 digital output
ACT20X-2HDI-2SDO
48
Power
supply
Zone 0
Tank
ACT20X
ACT20X-HDI-SDO-S / 2HDI-2SDO-S
PS
Technical Data
Input
Sensor
Sensor supply
Resistance
Input frequency
Pulse duration
Input resistance
Trigger level low / Trigger level high
Output signal in case of wire break
Output
Type
Switching frequency
Pulse duration
Rated switching voltage
Power rating
Voltage drop at max. load
Alarm output
Type
Nominal switching voltage
Continuous current
Power rating
General data
Power consumption
Supply voltage
NAMUR supply
Power consumption
Tightening torque, min. / Tightening torque, max.
Ambient temperature / Storage temperature
Insulation coordination
Insulation voltage
Rated voltage
EMC standards
Data for Ex applications (ATEX)
Voltage U0
Current I0
Power P0
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
3 W (2 channels)
19.2 31.2 V DC
8 V DC / 8 mA
3 W (2 channels)
0.4 Nm / 0.6 Nm
-20 C...+60 C / -20 C...+85 C
Ordering Data
1-channel version
2-channel version
Note:
Type
ACT20X-HDI-SDO-S
ACT20X-2HDI-2SDO-S
Qty.
1
1
Part No.
8965360000
8965390000
49
ACT20X
Ex label
Input signals
Ex-Output Signals
+V
Solenoid
Channel 1:
Alarm
14
44
13
43
12
42
11
41
+V
+V
Power Supply
Solenoid
Channel 2:
Alarm
+V
ATEX
II 3 G Ex nA nC IIC T4
II (1) G [Ex ia] IIC/IIB/IIA
II (1) D [Ex iaD]
IECEx
Ex nA nC IIC T4 Gc
[Ex ia Ga] IIC/IIB/IIA
[Ex ia Da] IIIC
FM
Installation in CL I DIV2 GP A-D T4
Protects Ex circuits, in compliance with
Cl. I-III ABT 1/2 GP A-G or
Cl. I Zn2 AEx/Ex nA nC [ia] IIC T4.
24
51
23
52
22
53
21
54
Gnd.
+19.2...31.2 V DC
Module status
N.C.
Module status
Output data
For gas group IIC ( 35 mA)
Control
system
Safe Zone
A.C. supply
DC
Power
supply
EX-Zone
Ignition protection group IIC
Connection terminal
Channel 2
U without load
21-22
Min. 24 V
21-23
Min. 24 V
21-24
Min. 24 V
19.2-31.2 V DC
Alarm signal
PS
Channel 1 digital output
Zone 0
ACT20X-2SDI-2HDO
Valve open/closed
signal
50
U with load
Min. 12.5 V
Min. 13.5 V
Min. 14.5 V
I max
35 mA
35 mA
35 mA
Ex alarm siren
+
-
Connection terminal
Channel 1
U without load
11-12
Min. 24 V
11-13
Min. 24 V
11-14
Min. 24 V
Solenoid valve
Tank
U with load
Min. 12.5 V
Min. 13.5 V
Min. 14.5 V
I max
35 mA
35 mA
35 mA
ACT20X
Solenoid driver
ACT20X-SDI-HDO / 2SDI-2HDO
PS
Technical Data
Input
Type
Input voltage
Input resistance, voltage
Trigger level low
Trigger level high
Alarm output
Type
Nominal switching voltage
Continuous current
Power rating
General data
Supply voltage
Power consumption
Tightening torque, min. / Tightening torque, max.
Ambient temperature / Storage temperature
Insulation coordination
Insulation voltage
Rated voltage
EMC standards
Data for Ex applications (ATEX)
Voltage U0
Current I0
Power P0
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
19.2 31.2 V DC
3.5 W (with 2 channels)
0.4 Nm / 0.6 Nm
-20 C...+60 C / -20 C...+85 C
2.6 kV (input / output)
300 V
DIN EN 61326
28 V DC
110 mA
0.95 W
Screw connection
2.5 / 0.5 / 2.5
119.2 / 22.5 / 113.6
cULus; FMEX; GOSTME25; IECEXKEM; KEMAATEX
Ordering Data
1-channel version
2-channel version
Note:
Type
ACT20X-SDI-HDO-L-S
ACT20X-2SDI-2HDO-S
Qty.
1
1
Part No.
8965400000
8965420000
51
ACT20X
Ex label
Ex Output Signals
Alarm
Solenoid
Input Signals
14
44
13
43
12
42
11
41
Channel 1:
Not connected
+V
+V
ATEX
II 3 G Ex nA nC IIC T4
II (1) G [Ex ia] IIC/IIB/IIA
II (1) D [Ex iaD]
IECEx
Ex nA nC IIC T4 Gc
[Ex ia Ga] IIC/IIB/IIA
[Ex ia Da] IIIC
FM
Installation in CL I DIV2 GP A-D T4
Protects Ex circuits, in compliance with
Cl. I-III ABT 1/2 GP A-G or
Cl. I Zn2 AEx/Ex nA nC [ia] IIC T4.
Channel 2:
Power supply
24
51
23
52
22
53
21
54
Not connected
Gnd
+19,2...31,2 V DC
Module status
N.C.
Module status
Output data
For gas group IIB ( 60 mA)
Control
system
Safe Zone
A.C. supply
DC
Power
supply
EX-Zone
Zone 1
Ignition protection group IIB
Ex alarm siren
Connection terminal
Channel 1
U without load U with load
Min. 9 V
11-12
Min. 24 V
Min. 11.5 V
Min. 12.5 V
11-13
Min. 24 V
Min. 10 V
Min. 11 V
11-14
Min. 24 V
Min. 13 V
19.2-31.2 V DC
Alarm signal
PS
PS
Zone 0
52
Tank
I max
60 mA
50 mA
60 mA
50 mA
60 mA
50 mA
ACT20X
Solenoid driver
ACT20X-SDI-HDO-H-S
PS
Technical Data
Input
Type
Input voltage
Input resistance, voltage
Trigger level low
Trigger level high
Alarm output
Type
Nominal switching voltage
Continuous current
Power rating
General data
Supply voltage
Power consumption
Tightening torque, min. / Tightening torque, max.
Ambient temperature / Storage temperature
Insulation coordination
Insulation voltage
Rated voltage
EMC standards
Data for Ex applications (ATEX)
Voltage U0
Current I0
Power P0
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
19.2 31.2 V DC
<2W
0.4 Nm / 0.6 Nm
-20 C...+60 C / -20 C...+85 C
2.6 kV (input / output)
300 V
DIN EN 61326
28 V DC
135 mA
0.77 W
Screw connection
2.5 / 0.5 / 2.5
119.2 / 22.5 / 113.6
cULus; FMEX; GOSTME25; IECEXKEM; KEMAATEX
Ordering Data
1-channel version
Note:
Type
ACT20X-SDI-HDO-H-S
Qty.
1
Part No.
8965410000
53
ACT20M Overview
54
ACT20M Overview
Saves space
6.1 mm
U, I,
R, T
U,I
PS
Signal splitter
Installation is simple and quick
The power supply is simply snapped
onto the rail bus for fast and easy
installation. The supply can be through
any ACT20M module or a separate
power-feed unit.
+70 C
to
25 C
Signal converter
Ex n
u;
Passive isolator
Power-feed modules
55
ACT20M
Signal splitter
ACT20M-AI-2AO-S
I, U
IN
I, U
OUT 2
2
1
7
82
83
I, U
OUT 1
Supply
Supply
Technical Data
Input
Input current
Input voltage
Sensor supply
Input resistance, voltage
Voltage drop, current input
Output
Output current
Output voltage
load impedance current
load impedance voltage
General data
Configuration
Supply voltage
Ambient temperature
Accuracy
Temperature coefficient
Cut-off frequency (-3 dB)
Power consumption, typ.
Power consumption, max.
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
0 20 mA
4 20 m
0 10 V
2 10 V
05V
1 5 V
0 ... 20 mA loop
4 ... 20 mA loop
0(4)...20 mA
0(2)...10 V, 0(1)...5 V
< 300 , per channel
10 k
0 20 mA
4 20 m
0 10 V
2 10 V
05V
1 5 V
2.5 kVeff
300 Veff
2
II
Screw connection
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5
CE; cULus; DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX
Switch
Output 2
8
0 20 mA
4 20 m
0 10 V
2 10 V
05V
1 5 V
10
= on
= off
ACT20M-AI-2AO-S
Screw connection
56
Switch
Ordering Data
Note:
Output 1
DIP switch
24 V DC 30 %
-25 C...+70 C
< 0.05 % of measuring range
0.01 % / C
100 Hz
400 mW
1.2 W
Note:
Switch
Input
0(4)...20 mA
0(2)10 V, 0(1)5 V
> 17 V DC at 20 mA
500 k
< 1.5 V
Type
ACT20M-AI-2AO-S
DIN mounting rail, see Accessories
Qty.
1
Part No.
1176020000
2-wire
mA
passive
In
PLC
V, mA
passive
Out 2
4-wire
V, mA
active
In
PLC
V, mA
passive
Out 2
4
3
2
5
6
U, I
U, I
U, I
Power
4
3
2
1
5
U, I
6
U, I
U, I
Power
7
8
Out 1
Power
24 V
PLC
V, mA
passive
Out 1
PLC
V, mA
passive
Power
24 V
ACT20M
Signal splitter
ACT20M-CI-2CO-S
I IN
I OUT 2
2
1
7
82
83
I OUT 1
Supply
Supply
Technical Data
ACT20M-CI-2CO-S
Input
Input current
Voltage drop, current input
Output
Output current
load impedance current
load impedance voltage
General data
Configuration
Supply voltage
Ambient temperature
Accuracy
Temperature coefficient
Cut-off frequency (-3 dB)
Power consumption, typ.
Power consumption, max.
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (MM)
Approvals
0(4)...20 mA
< 1.5 V
0(4)...20 mA
< 300 , per channel
10 k
4-wire
mA
active
In
PLC
mA
passive
Out 2
3
2
1
I
I
I
Power
7
8
Out 1
PLC
mA
passive
Power
24 V
none
24 V DC 30 %
-25 C...+70 C
< 0.05 % of measuring range
0.01 % / C
100 Hz
400 mW
0.8 W
2.5 kVeff
300 Veff
2
II
Screw connection
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5
CE; cULus; DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX
Note:
Ordering Data
Screw connection
Note:
Type
ACT20M-CI-2CO-S
Qty.
1
Part No.
1175990000
57
ACT20M
Signal converter
ACT20M-AI-AO-S
I, U
IN
1
82
83
I, U
OUT
Supply
Supply
Technical Data
Switch
Input
Input
Input current
Input voltage
Sensor supply
Input resistance, voltage
Voltage drop, current input
Output
Output current
Output voltage
load impedance current
load impedance voltage
General data
Configuration
Supply voltage
Ambient temperature
Accuracy
Temperature coefficient
Cut-off frequency (-3 dB)
Power consumption, typ.
Power consumption, max.
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
0(4)...20 mA
0(2)10 V, 0(1)5 V
> 17 V DC at 20 mA
>500 k
<1,5 V
0 20 mA
4 20 m
0 10 V
2 10 V
05V
1 5 V
0 ... 20 mA loop
4 ... 20 mA loop
0(4)...20 mA
0(2)...10 V, 0(1)...5 V
600
10 k
DIP switch
24 V DC 30 %
-25 C...+70 C
< 0.05 % of measuring range
0.01 % / C
100 Hz
400 mW
1.2 W
Ordering Data
Screw connection
Switch
5
Qty.
1
Part No.
1176000000
58
= on
= off
ACT20M-AI-AO-S
2-wire
mA
passive
In
4
3
5
6
U, I
U, I
2
Power
4-wire
V, mA
active
In
7
8
5
6
U, I
U, I
Note:
0 20 mA
4 20 m
0 10 V
2 10 V
05V
1 5 V
Type
ACT20M-AI-AO-S
Output 1
2.5 kVeff
300 Veff
2
II
Screw connection
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5
CE; cULus; DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX
Note:
Power
7
8
Out 1
Power
24 V
PLC
V, mA
passive
Out 1
PLC
V, mA
passive
Power
24 V
ACT20M
Signal isolator
ACT20M-CI-CO-S
Isolating DC signals
Power supply via the rail bus
3-way isolation
I IN
I OUT
1
82
83
Supply
Supply
Technical Data
Input
Input current
Voltage drop, current input
Output
Output current
load impedance current
General data
Configuration
Supply voltage
Ambient temperature
Accuracy
Temperature coefficient
Cut-off frequency (-3 dB)
Power consumption, typ.
Power consumption, max.
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
ACT20M-CI-CO-S
0(4)...20 mA
< 1.5 V
4-wire
mA
active
0(4)...20 mA
600
In
4
3
5
6
I
I
2
1
Power
7
8
Out 1
PLC
mA
passive
Power
24 V
none
24 V DC 30 %
-25 C...+70 C
< 0.05 % of measuring range
0.01 % / C
100 Hz
400 mW
0.8
2.5 kVeff
300 Veff
2
II
Screw connection
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5
CE; cULus; DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX;
ROHS
Note:
Ordering Data
Screw connection
Note:
Type
ACT20M-CI-CO-S
Qty.
1
Part No.
1175980000
59
ACT20M
ACT20M-UI-AO-S
4
3
I, U, R
IN
I, U
OUT
1
82
83
Supply
Supply
Technical Data
Input
Sensor
ACT20M-UI-AO-S
Potentiometer
Resistance
Input current
Input voltage
Input resistance, voltage
Voltage drop, current input
Sensor supply
Output
Output current
Output voltage
load impedance current
load impedance voltage
General data
Configuration
Supply voltage
Ambient temperature
Accuracy
Temperature coefficient
Power consumption, typ.
Power consumption, max.
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
4-wire
mA
active
4
3
U, I
Power
2-wire
mA
passive
In
7
8
5
U, I,
6
U, I
Power
7
8
Out 1
Power
24 V
PLC
mA
passive
Out 1
PLC
mA
passive
Power
24 V
ACT20M-UI-AO-S
+
4-wire
V
active
4
3
In
5
U, I,
U, I
Power
3
TC
In
Part No.
1176030000
7
8
5
U, I,
6
U, I
2
Power
Qty.
1
2
1
2.5 kVeff
300 Veff
2
II
Screw connection
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5
cULus; DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX
Type
ACT20M-UI-AO-S
Screw connection
5
U, I,
7
8
Out 1
Power
24 V
PLC
mA
passive
Out 1
PLC
mA
passive
Power
24 V
ACT20M-UI-AO-S
Ordering Data
60
0(4)...20 mA
0(2)...10 V, 0(1)...5 V
600
10 k
Note:
Note:
In
RTD
Sense +
R+
Sense
5
U, I,
6
U, I
Power
7
8
Out 1
PLC
mA
passive
Power
24 V
ACT20M
Passive isolator
ACT20M-CI-CO-ILP-S
I IN 1
I IN 2
I OUT 1
I OUT 2
Technical Data
Input
Voltage drop, current input
Input current
Output
Output current
load impedance current
General data
Configuration
Ambient temperature
Accuracy
Temperature coefficient
Cut-off frequency (-3 dB)
Power consumption, max.
Insulation coordination
Insulation voltage
Rated voltage
Pollution severity
Surge voltage category
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
2.5 kVeff
300 Veff
2
II
1-channel version
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5
DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX
Note:
ACT20M-CI-CO-ILP-S
4-wire
mA
active
In
0(4)...20 mA
600
none
-25 C...+70 C
< 0.1 % of measuring range
0.01 % / C
100 Hz
30 mW per channel
Out
PLC
mA
passive
Out 1
PLC
mA
passive
Out 2
PLC
mA
passive
7
I
ACT20M-2CI-2CO-ILP-S
4-wire
mA
active
In 1
4-wire
mA
active
In 2
4
3
2
1
5
I
I
6
7
I
I
Ordering Data
1-channel version
2-channel version
Note:
Type
ACT20M-CI-CO-ILP-S
ACT20M-2CI-2CO-ILP-S
Qty.
1
1
Part No.
1176070000
1176080000
61
ACT20M
Passive isolator
ACT20M-CI-CO-OLP-S
I IN 1
I IN 2
I OUT 1
I OUT 2
Technical Data
Input
Voltage drop, current input
Input current
Output
Output current
Supply voltage
General data
Configuration
Ambient temperature
Accuracy
Temperature coefficient
ACT20M-CI-CO-OLP-S
Typical 2.5 V
4...20 mA
2-wire
mA
passive
Ordering Data
Qty.
1
1
Out
PLC
mA
active
Out 1
PLC
mA
active
Out 2
PLC
mA
active
7
I
ACT20M-2CI-2CO-OLP-S
Type
ACT20M-CI-CO-OLP-S
ACT20M-2CI-2CO-OLP-S
2.5 kVeff
300 Veff
2
II
1-channel version
2.5 / 0.5 / 2.5
114.3 / 6.1 / 112.5
DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX
1-channel version
2-channel version
none
-25 C...+70 C
< 0.05 % of measuring range
0.07 A x ( C x V supply) @ Tamb < 25 C
, 0.02 A x ( C x V supply) @ Tamb > 25 C
100 Hz
30 mW per channel
Note:
62
4...20 mA
635V
Note:
In
Part No.
1176040000
1176050000
2-wire
mA
passive
In 1
2-wire
mA
passive
In 2
4
3
2
1
5
I
I
6
7
I
I
ACT20M-BAI-AO-S
ACT20M-BAI-2AO-S
I, V
IN
OUT 2
I, V
3
2
1
82 83
I, V
I, V
OUT 1
IN
I, V
OUT 2
Supply
I, V
Supply
7
82 83
OUT 1
Supply
Supply
Technical Data
Input
Input current
-10+10 mA / -20+20 mA
Input voltage
-10+10 V / -5+5 V
Output
Output current
0/420 mA 2x 0/420 mA or 1x 20 mA, 10 mA
Output voltage
05 V / 15 V / 010 V / 210 V
Load impedance current
< 600
Load impedance voltage
> 10 k
General data
Supply voltage
24 V DC 30 %
Ambient temperature (Operation
-25 C+70 C
-40 C+85 C
Storage temperature
Accuracy
< 0.05 % of measuring range
Temperature coefficient
< 0.01 % /K
Cut-off frequency
100 Hz 10 Hz
Insulation coordination
Insulation voltage
2.5 kV
Rated voltage
300 V
2
Pollution degree
Overvoltage protection
II
Dimensions
114.3 x 6.1 x 112.5
Length x width x height (mm)
2.5 / 0.5 / 2.5
Clamping range (nominal / min. / max.) (mm2)
Approvals
cULus 61010-1; FMEX; GL; DNV; IECEX; KEMAATEX; ROHS
-10+10 mA / -20+20 mA
-10+10 V / -5+5 V
2x 05 V / 15 V / 010 V / 210 V
2x 300
> 10 k
24 V DC 30 %
-25 C+70 C
-40 C+85 C
< 0.05 % of measuring range
< 0.01 % /K
100 Hz 10 Hz
2.5 kV
300 V
2
II
114.3 x 6.1 x 112.5
2.5 / 0.5 / 2.5
cULus 61010-1; FMEX; GL; DNV; IECEX; KEMAATEX; ROHS
Ordering Data
Type
Qty.
Part No.
ACT20M-BAI-AO-S 1
1375450000
Type
ACT20M-BAI-2AO-S
Qty.
1
Part No.
1375470000
Markers
Type
Qty.
MF 5/7.5 MC NEUTRAL
Type
Qty.
MF 5/7.5 MC NEUTRAL
Part No.
1877680000
Note:
Accessories
Part No.
1877680000
63
64
ACT20-Feed-In-BASIC-S
ACT20-Feed-In-PRO-S
Alarm
Power supply, 0 V 51
44 NC
Backup, +24 V 53
Backup, 0 V 54
NC
0V
+24 V
81
NC
82
NC
83
Status
0V
84
+24 V
NC
NC
85
Power supply, 0 V
Technical Data
Input
Supply voltage
Input current
Trigger level for the power supply
Output, power supply
Output voltage
Output power
Output current
Output, status relay in safe zone
Max. switching voltage, AC / Max. switching voltage, DC
Continuous current
AC power, max.
General data
Degree of efficiency
Ambient temperature
Power consumption
Protection degree
Weight
Humidity
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
21.6...26.4 V DC
Max. 4 A
21.6...26.4 V DC
Fault < 21 V DC
21.6...26.4 V DC
0.5...2.5 A DC
250 V / 30 V
2 A AC / DC
500 VA / 60 W
250 V / 30 V
0,976
-20 C...+60 C
<2W
IP 20
140
95 %, no condensation
Screw connection
2.5 / 0.5 / 2.5
119.2 / 22.5 / 113.6
DEKRAATEX; FMEX; GOSTME25; IECEXDEK
100 %
-25 C...+70 C
IP 20
70
95 %, no condensation
Screw connection
114.3 / 6.1 / 112.5
cULus; DETNORVER; FMEX; GL; GOSTME25; IECEXKEM; KEMAATEX
Ordering Data
Screw connection
Note:
Type
ACT20-FEED-IN-PRO-S
DIN mounting rail, see Accessories
Qty.
1
Part No.
8965500000
Type
ACT20-FEED-IN-BASIC-S
Qty.
1
Part No.
1282490000
65
66
Bus PCB
Ordering Data
Type
Qty.
10
10
5
Part No.
1248150000
1248160000
1248170000
Ordering Data
Type
Qty.
5
5
5
Part No.
1248180000
1248190000
1248210000
Ordering Data
Type
CH20M BUS 4.50/05 AU/250
CH20M BUS 4.50/05 AU/500
CH20M BUS 4.50/05 AU/750
Qty.
10
10
5
Cover plate
End plate
End plate
Ordering Data
Type
CH20M BUS-ADP TS35/250
CH20M BUS-ADP TS35/500
CH20M BUS-ADP TS35/750
Qty.
10
10
5
Part No.
1248250000
1248260000
1248270000
Ordering Data
Type
CH20M BUS-AP LI TS35x7.5 & 15
Qty.
Part No.
50 1193160000
Set
Set
Ordering Data
Type
SET CH20M BUS 250MM TS 35X15
Qty.
1
Part No.
1335150000
Ordering Data
Type
SET CH20M BUS 250MM TS 35X7.5
Qty.
1
Ordering Data
Type
CH20M BUS-AP RE TS35x7.5 & 15
Qty.
50
Part No.
1248220000
1248230000
1248240000
Part No.
1193170000
Part No.
1335140000
67
MICROSERIES Overview
MICROSERIES
Slim size great functionality
The MICROSERIES leads the field in analog signal
conditioning. It packs a great deal of functionality into its
thin 6.1 mm width. The enclosed version of the signal
converter is available with a screw connection (as MAS
variants) and with a tension clamp connection (as MAZ
variants). The MICROSERIES modules measure PT100
signals, thermocouple signals and DC-current/voltage
signals. They then electrically isolate and convert them into
standardized analog signals.
The DC/DC Select modules are one of the highlights in this
series. These 3-way isolators function to isolate and convert
DC standard signals. A DIP switch can be used to adapt
them to the particular application. The DC/DC Select HI
68
MICROSERIES Overview
Security
Electrical isolation increases the safety
of operations and reduces the risk of
facility malfunctions.
Supply isolator
69
With HART
MAS RPSH
2-conductor system
3-way isolation
With HART transmission
Output signal can be configured
With sensor feed
0V
24 V DC
cc
cc
U/I
PS
VC
1 I
PS
Current
Loop
Out
I 6
Technical Data
Input
Input current
Sensor
Sensor supply
Output
Output current
Output voltage
Output signal limit
Load impedance, voltage/current
Offset current
General data
Configuration
Supply voltage
Power consumption
Accuracy
Step response time
Temperature coefficient
Ambient temperature
Insulation coordination
Standards
EMC standards
Rated voltage
Insulation voltage
Surge voltage category
Pollution severity
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
4...20 mA
2-wire
16.5 V / constant for 3 22 mA
Output
4 ... 20 mA
0 ... 20 mA
0 ... 10 V
0(4)...20 mA
0...10 V
22...25 mA or 11...12.5 V
10 k / 500
< 30 A
70
Qty.
1
IN
+
Ordering Data
Note:
PS
-
mA
Type
MAS RPSH
= on
= off
DIP switch
24 V DC 15 %
ca. 1 W
IOUT: < 0.1 % / UOUT: < 0.2%
2 ms
50 ppm/K
0 C...+55 C
Screw connection
Schalter
Switch
2
3
Part No.
8721170000
PS
U/I
OU T
mA
Without HART
MAS RPS
2-conductor system
3-way isolation
Power supply can be cross-connected
With sensor feed
0V
24 V DC
cc
cc
PS
VC
1 I
PS
Current
Loop
Out
I 6
Connection
Technical Data
Input
Input current
Sensor
Sensor supply
Output
Output current
Output signal limit
Load impedance, voltage/current
Offset current
General data
Configuration
Supply voltage
Power consumption
Accuracy
Step response time
Temperature coefficient
Ambient temperature
Insulation coordination
Standards
EMC standards
Rated voltage
Insulation voltage
Surge voltage category
Pollution severity
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
PS
4...20 mA
2-wire
16.5 V / constant for 3 22 mA
4...20 mA
22...25 mA
/ 500
< 30 A
mA
IN
+
none
24 V DC 15 %
ca. 1 W
< 0,1 %
2 ms
50 ppm/K
0 C...+55 C
PS
OU T
mA
Ordering Data
Screw connection
Note:
Type
MAS RPS
Qty.
1
Part No.
8721150000
71
PT100
U/I
VC
Technical Data
Input
Sensor
Sensor supply
Temperature input range
Output
Output voltage / Output current
Load impedance, voltage/current
General data
Configuration
Supply voltage
Power consumption
Accuracy
Step response time
Temperature coefficient
Ambient temperature
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Surge voltage category
Pollution severity
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
Output
0 ... 10 V
0 ... 20 mA
4 ... 20 mA
0 ... 5 V
Note:
72
Connection
PS
3
2
Pt 10 0
V/I
5
6
OUT
Ordering Data
Type
MAS PT100 0100C EX
= on
= off
Screw connection
Schalter
Switch
2
3
Qty.
1
Part No.
8975690000
mA
U/I
VC
Technical Data
Input
Sensor
Temperature input range
Output
Output voltage / Output current
Load impedance, voltage/current
Wire break detection
General data
Configuration
Supply voltage
Power consumption
Accuracy
Step response time
Temperature coefficient
Ambient temperature
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Surge voltage category
Pollution severity
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
Output
0 ... 10 V
0 ... 20 mA
4 ... 20 mA
0 ... 5 V
Switch
2
3
mA
= on
= off
Connection
PS
IN
+
V/I
OUT
Ordering Data
Screw connection
Note:
Type
MAS Thermo-K 01000C EX
Qty.
1
Part No.
8975710000
73
U/I
VC
Technical Data
Input
Sensor
Temperature input range
Output
Output voltage / Output current
Load impedance, voltage/current
Wire break detection
General data
Configuration
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Surge voltage category
Pollution severity
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
Output
0 ... 10 V
0 ... 20 mA
4 ... 20 mA
0 ... 5 V
Note:
74
mA
Connection
PS
IN
+
Ordering Data
Type
MAS THERMO-J 0700C EX
= on
= off
Screw connection
Switch
2
3
Qty.
1
Part No.
8975730000
V/I
OUT
Configurable
DC/DC select
3-way isolation
Can be configured via DIP switch
Power supply can be cross-connected
Minimal power loss
Technical Data
Input
Input voltage / Input current
Input resistance, voltage/current
Voltage drop
Output
Output voltage / Output current
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Ambient temperature
Storage temperature
Insulation coordination
Standards
EMC standards
Rated voltage
Insulation voltage
Overvoltage category
Pollution severity
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
0...10 V / 0(4)...20 mA
100 k / 5
< 0.1 V @ IIN =20 mA (current input)
Switch
S1
0...10 V / 0(4)...20 mA
10 k / 500
> 100 Hz
24 V DC 15 %
ca. 0.6 W
< 0.5 % of end value
150 ppm/K of of final value
0 C...+55 C
-20 C...+85 C
Output
0 20 mA
0 20 mA
0 20 mA
4 20 mA
0 10 V
4 20 mA
0 20 mA
4 20 mA
4 20 mA
4 20 mA
0 10 V
0 10V
0 10V
0 20 mA
4 20 mA
0 10V
0 10 V
EN 50178
DIN EN 61326
50 V
500 Veff / 1 s
II
2
Screw connection
2.5 / 0.5 / 2.5
88 / 6.1 / 97.8
cURus; CE; cULusEX
PS
Qty.
1
1
mA
IN
+
Type
MAS DC/DC select
MAZ DC/DC select
S2
2
Connection
Screw connection
Tension clamp connection
= on
= off
Ordering Data
Note:
Input
0 20 mA
PS
V/I
V/I
OUT
mA
Part No.
8594810000
8594840000
75
76
User-definable
characterisation
If none of the standard input
linearisation options suit
the sensor, a special curve
can easily be created.
77
WAVE TTA EX
Analogue Inputs
3 Port Isolation
Relay
Channel 1
Relay
Channel 2
Output
0 ... 11 V /
0 ... 22 mA
J V, I
V, I
+24 V DC
PS
Technical Data
Typical functions
Input
Sensor
Potentiometer
Resistance
Input frequency
Input voltage
Input current
Sensor supply
Output analog
Output voltage
Output current
Load impedance, voltage/current
Signal output
Transmit function
Output digital
Type
Switching voltage AC, max. / DC, max.
Continuous current
General data
Configuration
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Note:
78
Converter
f, I, V
I, V
PS
I, V
Type
WAS6 TTA EX
WAZ6 TTA EX
PS
Ordering Data
Screw connection
Tension clamp connection
I, V
Transmitter
Isolator
I
Qty.
1
1
Part No.
8964310000
8964320000
PS
Lineariser
I, V
I, V
PS
Trip amplifier
J
PS
79
ITXPlus
Universal, loop powered signal isolating converter
The ITXPlus is a compact signal isolating converter that is
loop-powered, programmable and electrically isolated. On
the input side, the user can connect DC-current/voltage
signals, 2-, 3-, or 4-wire PT100s, and thermocouples. The
ITXPlus measures, filters and isolates the input signals. It
converts them into a proportional signal from 4 to 20 mA.
The ITXPlus provides a 4 to 20 mA current loop output.
For linear temperature measurements, you can connect
all standard types of thermocouples and resistance
temperature detectors (RTDs). The ITXPlus can also process
signals from any non-linear device, such as a NTC or PTC
sensor, or log. potentiometer. User-definable curves can be
programmed into a table containing up to 101 co-ordinates
for thermocouple and RTD ranges and 25 for other variables.
Technical Data
Thermocouple inputs
Inputs
Type
Type
B
C
E
J
K
L
N
R
S
T
W3, W5
User-defined Input
Cold-junction compensation
Wire-break recognition
Standard
IEC584
DIN 43710
IEC584
ASTM E98890
2, 3, 4-wire RTD
mA
Volt
mV
Resistance
Accuracy
Type
Standard
PT 100
DIN 43710
PT 100
JIS
PT 200
DIN 43710
PT 200
JIS
NI 120
DIN 43710
CU 100
DIN 43710
Cable resistance
Sensor current
Influence of cable resistance sensor (3/4 wire)
Lower limit
200 C
200 C
200 C
200 C
80 C
100 C
5 max.
0,1 mA
< 0.002 per wire resistance
0 to 10 k (min. range 10 )
Type
E,J,K,L,N,T,U
Temperature coefficient
0.02 C per C ambient temperature
0.01 % of end value per C ambient temperature
0.02 C per C ambient temperature
B, C, R, S, W3, W5
mV, V, mA
PT100/RTD
Resistance
80
Range
< 500 C
> 500 C
All
Upper limit
850 C
630 C
850 C
630 C
320 C
260 C
Min. range
200 C
50 C
100 C
200 C
50 C
200 C
Min. range
50 C
100 C
Accuracy
1.0 C
2.0 C
0.1 % of end value
0.5 C
0.1 % of end value
ITXPlus
ITXPlus
+24 V
+
J/V/I
2
3
Iout
Technical Data
Connections
Input
Type
RTD, TC, DC (mA, V), Voltages ( 100 mV), Current input [mA],
Thermocouple
B / C / E / J / K / L / N / R / S / T / W3 / W5
- 200...+ 2300 C depending on thermocouple
PT100, PT1000, (EN 60571) Ni100, Ni1000, (JIS1604), Cu10, Cu25,
Cu50, Cu100 (DIN 43760) 2-/3-/4-Leiter
-10...+20 mA (min. span 1 mA)
-5...+10 V / -100...+200 mV (min. span 0.5 V / 4 mV)
2 M / 40
Type, thermocouple
Type, RTD
Input current
Input voltage
Input resistance, voltage/current
Output
Type
Output current
load impedance current
General data
Configuration
Supply voltage
Humidity
Temperature coefficient
Ambient temperature / Storage temperature
Long-term drift
Step response time
Insulation coordination
Impulse withstand voltage
Rated voltage
Insulation voltage
EMC standards
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
Current output
4...20 mA
typ. 700 @ 24 V DC
T Set Software
10...40 V DC, loop powered
10...90 % (no condensation)
typ. 0.02 % / C
-10 C...+70 C / -20 C...+70 C
0.1 % / 10.000 h
Typ. 200 ms (10...90%)
4 kV (1.2/50 s)
300 Veff
2 kV input / output
DIN EN 61326
Screw connection
1.5 / 0.5 / 2.5
92.4 / 12.5 / 112.4
CE; cULus; cULusEX
Terminal
5
Signal
Loop ve
Loop +ve
1
3
2
4
1
3
2
3
2
1
2
1
2
3
1
2
Supply voltage
Thermocouple
4-wire PT100/RTD
(or resistance)
3-wire PT100/RTD
(or resistance)
2-wire PT100/RTD
(or resistance)
Voltage (mV or V)
Current (mA)
Potentiometer
Ordering Data
Universal input
Note:
Type
ITXPlus
Qty.
1
Part No.
7940016563
81
Configurable
PRO DC/DC
U/I
U/I
VC
Technical Data
Input
Input voltage / Input current
Input resistance, voltage/current
Output
Output voltage / Output current
Load impedance, voltage/current
Cut-off frequency (-3 dB)
Offset current / Offset voltage
Adjustment range, zero point
Adjustment range, amplification
Displacement
General data
Configuration
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Ambient temperature
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage input or output/supply
Surge voltage category
Pollution severity
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
Note:
Type
WAS4 PRO DC/DC
WAZ4 PRO DC/DC
Qty.
1
1
Part No.
8560740000
8560750000
Output
Output range
0 10 V
2 10 V
0 5 V
15V
0 20 mA
4 20 mA
Offset
(in % of output voltage)
0%
-100 %
-50 %
+50 %
+100 %
Zero pot. activated: additional 25 %
S2
2
S1
5 6
S1
9 10
Switch
S3
S2
5
82
Switch
Switch S2
calibrated ranges
Span-pot. activated: input x 0.33 ... x 3.30
non calibrated range
Ordering Data
Screw connection
Tension clamp connection
Input
S1
Input range
1 2 3
0 60 mV
0 100 mV
0 150 mV
0 300 mV
0 500 mV
0 1 V
0 5 V
0 10 V
0 100 V
0 + 0.3 mA
0 1 mA
0 5 mA
0 10 mA
0 20 mA
0 50 mA
4 20 mA*
*Offset conversion not calibrated
Configurable
WAVEPak
3-way isolator
2
3
4
3
4
H
Iin
0V
Vin
+24 V
1
Technical Data
PS
Iout
8
0V
V/I
Vout
V/I
5
6
PS
0V
8
0V
V/I
Vin
Iout
Vout
V/I
5
6
2
3
4
0V
TP+
+24 V
+24 V
1
0V
7
PS
8
0V
V/I
V/I
TP
Iout
Vout
5
6
Connections
Input
Type
Input signal
Sensor supply
Input resistance, voltage/current
Resolution
Output
Type
Output current / Output voltage
load impedance current
load impedance voltage
General data
Configuration
Supply voltage
Power consumption
Linearity
Humidity
Ambient temperature / Storage temperature
Temperature coefficient
Long-term drift
Step response time
Insulation coordination
Impulse withstand voltage
EMC standards
Insulation voltage
Rated voltage
Surge voltage category
Pollution severity
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
Iin
0V
7
+24 V
1
+24 V
0V
Current or voltage output1 configurable with
7 jumper
Iout
V or 0...10 V
0...220mA
2
PS
20TP+
mA @ 24 V DC output
100V
>31 M /+24
3.5 A / 1.76 mV per bitV/I
Vout
8
0V
4
V/I
TP of voltage output, configured with jumper
Current
0...22 mA / 0...10 V
1k
Connections
500
Terminal
Signal
1 switch Signal +
DIP
Supply voltage
7
12...60
V DC Signal
4 W @ 24 VSignal
2.5
DC +
Voltage input
Signal0.05 %)
<3 0.1 % (typically
210...90 % (no condensation)
Signal +
Current input
03 C...+60 C /Signal
-25 C...+70
C
3
Signal +
0.05 % / C
Loop Powered Input
2
Signal
0.1 % / 10.000 h
6
Signal +
< 220 ms (10...90 %)
Voltage output
5
Signal
CE; cULus; cULusEX
8
Signal +
Current output
45 kV (1.2/50 s)
Signal
DIN EN 61326
2 kV input / output / power supply
300 Veff
III
2
Screw connection
1.5 / 0.5 / 2.5
92.4 / 12.5 / 112.4
CE; cULus; cULusEX
5
6
Terminal
1
7
4
3
2
3
3
2
6
5
8
5
Signal
Signal +
Signal
Signal +
Signal
Signal +
Signal
Signal +
Signal
Signal +
Signal
Signal +
Signal
Supply voltage
Voltage input
Current input
Loop Powered Input
Voltage output
Current output
Ordering Data
Universal converter
Note:
Type
WAVEPak DC/DC
Qty.
1
Part No.
7940024139
83
CBX200
CBX200 USB
Technical Data
Input
Type
Input current
Input resistance
Input voltage
Output
Type
Output voltage
Output current
Level on interfaces
Baud rate
Activation signal
Insulation coordination
Insulation voltage
CBX100
CBX200
X
X
X
X
Ordering Data
Type
CBX200 USB
Qty.
1
Part No.
8978580000
RxD
TxD
Vcc/control input
DTR*
0
1
Vcc
3,3 V
0V
Control input
12 V
12 V
0V
0V
RTS*
1
0
1
0
RS232 interface
active
active
active
not active
Installation notes
The power supply to the device comes from the USB port
via a USB type-A plug. The output-side of the RS232 interface
uses a four-pole 2.5-mm jack plug to connect. This jack plug
is also capable of activating the RS232 interface when needed
with a 12-V control voltage. With the assistance of the DTM,
the USB interface is diverted to a COM interface. The RS232
interface can be activated with an RTS signal
(RTS = 1 output activated) via the diverted COM interface.
The jack plug is also capable of supplying the RS232 node
with a regulated voltage of 3.3 V at 4 mA current.
The DTR signal (DTR = 0 supply activated) is used for control.
It is also possible to query the status using the DSR signal
(DSR = 0 output activated).
The "WI-Manager" software, the "TTA Set" and the
www.weidmuller.com.
DTM
library can all be downloaded free of charge from
www.weidmueller.com.
84
CBX100
CBX100 USB
Technical Data
Display
Status indicator
General data
Insulation voltage
Ambient temperature / Storage temperature
Humidity
Approvals
CBX100
CBX200
X
X
X
X
Wiring diagram
Ordering Data
Type
CBX100USB
Qty.
1
Part No.
7940025031
Converter
1
2
3
4
Output
Input
PC
CBX100
85
U/I
4...20 mA / 0...10 V
0...10 V / 4...20 mA
UL Class I, Div. 2
UL Class I, Div. 2
U/I
VC
Technical Data
Input
Input voltage / Input current
Input resistance, voltage/current
Output
Output voltage / Output current
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Surge voltage category
Pollution severity
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
/ 4...20 mA
/ 50
0...10 V /
500 k /
0...10 V /
2 k / 600
15 kHz (typ. 20 kHz)
/ 4...20 mA
/ 500
15 kHz (typ. 20 kHz)
none
24 V DC 25 %
< 1.3 W @ IOUT = 5 mA
< 0.2 % of end value
250 ppm/K of final value
40 s (typ. 30 s)
0 C...+55 C
none
24 V DC 25 %
< 1.5 W @ IOUT = 20 mA
0.2 % of final value
250 ppm/K of final value
40 s (typ. 30 s)
0 C...+55 C
Ordering Data
Screw connection
Note:
86
Type
WAS5 CVC HF 4-20/0-10V
Qty.
1
Part No.
8447280000
Type
WAS5 VCC HF 0-10/4-20MA
Qty.
1
Part No.
8447340000
Supply on outputside
Signal conversion
Galvanic isolation between input and
output signals
Power supply can be cross-connected using
plug-in jumpers
4...20 mA / 4...20 mA
4...20 mA / 0...10 V
UL Class I, Div. 2
UL Class I, Div. 2
I
U/I
VC
Technical Data
Input
Input voltage / Input current
Output
Output voltage / Output current
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Current consumption
Current-carrying capacity of cross-connect.
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Surge voltage category
Pollution severity
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
/ 4...20 mA
/ 500
15 Hz (typ. 20 Hz)
0...10 V /
1 k /
15 Hz (typ. 20 Hz)
none
24 V DC 20 %
< 32 mA @ IOUT = 20 mA
2A
0.2 % of final value
250 ppm/K of final value
30 ms (typ. 20 ms)
0 C...+55 C
none
24 V DC 20 %
< 20 mA @ IOUT = 10 mA
2A
0.2 % of final value
250 ppm/K of final value
30 ms (typ. 20 ms)
0 C...+55 C
Type
WAS4 CCC DC 4-20/4-20MA
WAZ4 CCC DC 4-20/4-20MA
Type
WAS4 CVC DC 4-20/0-10V
Ordering Data
Screw connection
Tension clamp connection
Note:
Qty.
1
1
Part No.
8444980000
8444990000
Qty.
1
Part No.
8445040000
87
2OLP
Galvanic isolation
Input and output current loop feed
Very low power consumption
No calibration necessary
ATEX II 3 G Ex nA IIC T4
UL Class I, Div. 2
I
I
Technical Data
Example of application
Input
Input current
Voltage drop
Output
Output current
Output signal limit
Load impedance, voltage/current
Cut-off frequency (-3 dB)
General data
Configuration
Supply voltage
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage input or output/supply
Surge voltage category
Pollution severity
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
~
Sensor
230 V AC
4 ... 20 mA
none
min. 12 V DC/ max. 30 V DC
typ. 0.1 %; max. 0.2 %
150 ppm/K
< 20 ms
0 C...+55 C
4 ... 20 mA
1
2
3
Screw connection
88
24 V DC
24 V DC
230 V AC
Ordering Data
Notes:
230 V AC
Type
WAS5 CCC 2OLP EX
Markers refer to Accessories.
Qty.
1
Part No.
8975640000
24 V DC
WAVE ANALOGUE
2OLP
8581160000/8581170000
7
8
9
10
11
12
SPS
PRO RTD
RTD
J,R
UL Class I, Div. 2
U/I
VC
Technical Data
Input
Sensor
0(4)...20 mA / 0...10 V
max. 100 A / max. 0.05 V
1 k / 600
LED flashing (output value: > 20 mA, >10 V)
5 %, Version 1 and later: 12.5 % / potentiometer: 12.5%...25%
Module active: LED on/ wire breakage: LED flashing/
Error: LED off
General data
Configuration
Supply voltage
Power consumption
Step response time
Ambient temperature
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Surge voltage category
Pollution severity
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
Ordering Data
Screw connection
Tension clamp connection
Note:
Type
WAS5 PRO RTD
WAZ5 PRO RTD
Qty.
1
1
Part No.
8560700000
8560710000
89
PRO RTD
Switch position / setting options
Choice of inputs
Switch 1
Input
1
2
3
PT100 2-wire
PT100 3-wire
PT100 4-wire
R
2-wire
NI100 2-wire
NI100 3-wire
NI100 4-wire
Potentiometer
min
0 C
-10 C
-20 C
-25 C
-30 C
-40 C
-50 C
-60 C
-70 C
-80 C
-90 C
-100 C
-150 C
-200 C
Choice of step
response time
Step response time
slow
fast
10
10 %
20
20 %
20
25 %
30
30 %
40
40 %
50
50 %
60
60 %
70
70 %
80
80 %
90
100
150
200
Special area
90
Choice of outputs
Switch 2
Output
6
7
0...10 V
0...5 V
0...20 mA
4...20 mA
= on
= off
R
20
25
30
35
40
45
50
55
60
62,5
65
70
75
80
85
90
95
100
125
150
175
200
225
250
275
300
325
350
375
400
425
450
Poti
20 %
25 %
30 %
35 %
40 %
45 %
50 %
55 %
60 %
62,5 %
65 %
70 %
75 %
80 %
85 %
90 %
95 %
100 %
-----------------------------
on
S. 2
8
Temperature coefficient
Measuring range 200 K
100 K Measuring range < 200 K
40 K Measuring range < 100 K
200 ppm / C
250 ppm / C
400 ppm / C
Switch 2
2
3
4
Temperature adjustment:
Output
DIP switch
Span
420 mA
-10 C+110 C
75110 C
Range
Adjustment range
120 C
12.5 %
Zero
25 C
10 C
95 C
110 C
125 C
5 C
Span
5 C
110 C
125 C
140 C
PRO RTD Cu
Cu
Selection of connection
Switch 1
Connection
1
3-wire
4-wire
UL Class I, Div.2
min
0 C
10 C
20 C
25 C
30 C
40 C
50 C
60 C
70 C
80 C
90 C
100 C
150 C
200 C
U/I
VC
Technical Data
Input
Sensor
Temperature input range
Output
Output current / Output voltage
Offset current / Offset voltage
Load impedance, voltage/current
Wire break detection
Fine adjustment
Status indicator
General data
Configuration
Supply voltage
Power consumption
Step response time
Ambient temperature
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Surge voltage category
Pollution severity
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
Ordering Data
Screw connection
Note:
Type
WAS5 PRO RTD Cu
Qty.
1
Part No.
8638950000
Span
40 K
50 K
60 K
70 K
80 K
90 K
100 K
110 K
120 K
125 K
130 K
140 K
150 K
160 K
170 K
180 K
190 K
200 K
210 K
220 K
230 K
240 K
250 K
260 K
270 K
280 K
290 K
300 K
350 K
400 K
450 K
460 K
special range
0(4)...20 mA / 0...10 V
max. 100 A / max. 0.05 V
1 k / 600
LED flashing (output value: > 20 mA, >10 V)
12.5% of FSR
Module active: LED on/ wire breakage: LED flashing/
Error: LED off
Type
Cu 10
Cu 25
Cu 50
Cu 100
Selection of senor
Switch 1
2
3
Selection of Output
Switch 2
Connection 6
7
0 ... 10 V
0 ... 20 mA
4 ... 20 mA
Switching on the
manual fine adjustment
Switch 1
man adj.
8
off
on
Switch 2
8
= on
= off
91
PRO Thermo
UL Class I, Div. 2
Typ
K
J
T
E
N
R
S
B
Select of
thermocoupler
SW1
1
2
U/I
J
VC
Technical Data
Input
Sensor
Temperature input range
Output
Output voltage / Output current
Load impedance, voltage/current
Offset current / Offset voltage
Line resistance in measuring circuit
Wire break detection
Fine adjustment
Status indicator
General data
Configuration
Supply voltage
Power consumption
Step response time
Current-carrying capacity of cross-connect.
Ambient temperature
Storage temperature
Default setting
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Surge voltage category
Pollution severity
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
DIP switch
24 V DC 25 %
800...850...950 mW at IOUT = 20 mA
without filter: max. 1.4 s; with filter: max. 7.5 s
2A
0 C...+55 C
-20 C...+85 C
Type K; 0...1000C; 4...20mA; filter: off; man. calibration: off
DIN EN 50178, DIN EN 61000-4-2
EN 55011, EN 61000-6
300
4 kV
2 kVeff / 5 s
III
2
3 mm
Screw connection
Tension clamp connection
2.5 / 0.5 / 2.5
1.5 / 0.5 / 2.5
92.4 / 17.5 / 112.4
92.4 / 17.5 / 112.4
CE; cULusEX; GL; cULus
Ordering Data
Screw connection
Tension clamp connection
Note:
92
Type
WAS5 PRO Thermo
WAZ5 PRO Thermo
Qty.
1
1
Part No.
8560720000
8560730000
Selection of
temperature span
SW2
Span
1 2 3 4 5
100 C
150 C
200 C
250 C
300 C
350 C
400 C
450 C
500 C
550 C
600 C
650 C
700 C
750 C
800 C
850 C
900 C
950 C
1000 C
1050 C
1100 C
1150 C
1200 C
1250 C
1300 C
1350 C
1400 C
1450 C
1500 C
1600 C
1700 C
1800 C
Accuracy
K -200 C -150 C
-150 C 1200 C
1200 C 1372 C
J -200 C -150 C
-150 C 1200 C
T -200 C -150 C
-150 C 400 C
E -200 C -150 C
-150 C 1000 C
N -200 C -150 C
-150 C 1300 C
R -50 C 200 C
200 C 1760 C
S -50 C 200 C
200 C 1760 C
B 50 C 250 C
250 C 500 C
500 C 1820 C
Selection of minimum
temperature
SW1
min
1 2 3
0 C
10 C
20 C
30 C
40 C
50 C
100 C
150 C
200 C
+ 50 C
+ 100 C
+ 150 C
+ 200 C
+ 250 C
+ 500 C
Special range
Selection of output
Switch 2
Output
6
7
0 ... 10 V
0 ... 20 V
4 ... 20 V
Switching on the
manual fine adjustment
SW 2
man. adjust.
off
on
Switching on the
filter function
SW 2
Filter
off
on
= on
= off
WAVEPRO Frequency
WAVEANALOG PRO Frequency
delivers settings help, for any
input and output values.
The input range is set using
the DIP switches (a frequency
generator is not required)
There are 2 different methods:
1. Lower measuring frequency = 0 Hz
Choose operating mode = fmax
S2.3 = 0 and S2.4 = 0
Set the upper measuring frequency
using DIP switches S1 and S2.1,
S2.2 (see table)
Thats all!
2. Lower measuring frequency 0 Hz
First the lower measuring frequency
must be saved. Select mode save
fmin. S2.3 = 1 and S2.4 = 0. Set
the frequency using DIP switches S1
and S2.1, S2.2 (see table) To save
the frequency, briefly connect the
module to the power supply.
Select mode fmin fmax
S2.3 = 0 and S2.4 = 1
Set the upper measuring frequency
using DIP switches S1 and S2.1,
S2.2 (see table).
Thats all!
93
f/DC isolator/converter
PRO Frequency
3-way isolation
Max. input frequency: 100 kHz
Input and output ranges adjustable via DIP
switch
No calibration necessary
Programmable custom range
WAVETOOL software helps with configuration,
download at www.weidmuller.com
UL Class I, Div. 2
Selecting the
operating mode
Operating mode
U/I
0 fmax
fmin fmax
saving
of fmin
VC
Switch 2
3 4
f = (A+B) x C
Technical Data
Input
Sensor
Rated input level
Output
Output voltage / Output current
Load impedance, voltage/current
Offset current / Offset voltage
Status indicator
General data
Configuration
Supply voltage
Power consumption
Accuracy
Temperature coefficient
Step response time
Ambient temperature
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Insulation voltage
Surge voltage category
Pollution severity
Clearance & creepage distances
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
0...10 V / 0(4)...20 mA
1 k / 600
max. 100 A / max. 0.05 V
Green LED
DIP switch
24 V DC 25 %
Max. 1.6 W at IOUT = 20 mA
< 0.2% of output range
Max. 200 ppm/K of output range
360 ms + 2 times the period time of input frequency
0 C...+55 C
A
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
Screw connection
Tension clamp connection
Note:
Qty.
1
1
Part No.
8581180000
8581190000
Output
010 V
020 mA
420 mA
05 V
Selecting
the frequency
Switch 1
5 6 7
B
0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
0.9
C
x1
x10
x100
x1000
Selecting
the frequency
Switch 2
1
2
Application
230 V AC
24 V DC
7 8
Registering motor
revolutions using
Namur sensor
1 2
3 4
N
N+
Namur
activated: <= 1,2 mA
not activated: >= 2,1 mA
SPS
020 mA
WAVEANALOG
PRO FREQUENCY
8581180000/8581190000
5 6
94
= on
= off
Ordering Data
Type
WAS4 PRO Freq
WAZ4 PRO Freq
Selecting
the frequency
Switch1
1 2 3
Analog output
1/5/10 A AC 4...20 mA
Monitors AC currents
Input and output are electrically isolated
Input and output ranges adjustable via
DIPswitch
No calibration required
ATEX II 3 G nL IIC T4
UL Class I, Div.2
Loop-powered
I AC
U/I
VC
+ 24 V 7
NC
IN
NC 8
4...20 mA 9
Technical Data
Input
Input current
Input frequency
Max. current
Voltage of measuring circuit
Sensor
Output
Output current / Output voltage
Offset current
Output signal limit
Load impedance, voltage/current
Step response time
Accuracy
Temperature coefficient
Status indicator
General data
Configuration
Supply voltage
Current consumption
Current-carrying capacity of cross-connect.
Ambient temperature / Storage temperature
Default setting
Insulation coordination
Standards
EMC standards
Rated voltage
Impulse withstand voltage
Pollution severity
Surge voltage category
Clearance & creepage distances
Insulation voltage
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
DIP switch
13...30 V DC
Ordering Data
Screw connection
Tension clamp connection
Note:
Type
WAS1 CMA LP 1/5/10A EX
WAZ1 CMA LP 1/5/10A EX
Qty.
1
1
Part No.
8975590000
8975610000
95
+ 24 V
0V
4 ... 20 mA = 0-150.0 kl
or %
+ Input
Tank container
DI350
Input
Power supply
Transmitter [dB]
+24 V
7
1
2
3
4
Connections
Terminal
1
2
3
4
5
6
7
8
PS
+ 24 V
0V
Vin/Iin
V/I
0V
Signal
24 V DC
power supply sensor
0 V DC
power supply sensor
Input signal +
Input signal
Inputs
Not used
L
L+
Supply voltage
137.0 mm
96.6 mm
60.0 mm
15.5mm
96.6 mm
15.5mm
18.0 mm
96
Cut-out
48.8 mm
44.7 mm
143.5 mm
DI350
DI350
DI350
L
W
Technical Data
Input
Input signal
Input resistance
Supply voltage
Display
Type
Display range
Display value
Format
Settings
Offset
Range of adjustment
General Data
Supply voltage
Power consumption
Linearity
Humidity
Temperature coefficient
Long-term drift
Step response time
Impulse withstand voltage
Insulation voltage
Ambient temperature / Storage temperature
EMC standards
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
0...10 V
1 M
24 V DC (up to 25 mA)
4...20 mA
22
24 V DC (up to 25 mA)
24 V DC (12...35 V DC)
6 W @ 24 V DC
< 0.1 % typ.
0...90 % (no condensation)
0.02 % / C
0.1 % / 10.000 h
200 ms (10...90 %)
4 kV (1.2/50 s)
1 kV input / power supply
0 C...+60 C / -25 C...+70 C
DIN EN 61326
Screw connection
1.5 / 0.5 / 2.5
137 / 96.6 / 48.8
CE; cULus; cULusEX
24 V DC (12...35 V DC)
6 W @ 24 V DC
< 0.1 % typ.
0...90 % (no condensation)
0.02 % / C
0.1 % / 10.000 h
200 ms (10...90 %)
4 kV (1.2/50 s)
1 kV input / power supply
0 C...+60 C / -25 C...+70 C
DIN EN 61326
Screw connection
1.5 / 0.5 / 2.5
137 / 96.6 / 48.8
CE; cULus; cULusEX
Ordering Data
Voltage input/Current input
Type
DI350 0-10V/0-100.0
Qty.
1
Part No.
7940011570
Type
DI350 4-20mA/0-100.0
Qty.
1
Part No.
7940010185
97
LPD350
Input
24 V DC
4 ... 20 mA
98
PLC
75 mm
96.6 mm
44.7 mm
48.8 mm
65 mm
18.0 mm
96.6 mm
Output
4 ... 20 mA
Power supply
WAVEPak
Isolator
Temperature
probe
Cut-out
91 mm
LPD350
LPD350
Current input
Iin
0V
L
W
Technical Data
Connections
Input
Input current
Voltage drop
Input resistance
Input current, max.
Input current, max. when wired incorrectly
Display
Type
Display range
Format
Settings
Offset
Range of adjustment
General data
Accuracy
Repeat accuracy
Temperature coefficient
Terminal
Signal
14...20 mA
Input
22.5 V @ 20 mAInput +
125
100 mA constant / 500 mA for 10 sec.
500 mA constant
Ordering1 Data
Current input
Type
LPD350 4-20mA/0-100.0
Qty.
1
Part No.
7940010163
Connections
Terminal
1
2
Signal
Input
Input +
99
PLC control
level /enterprise
management
level
24 V DC
Measurement
probe
(hall sensor)
140 mm
65 mm
80 mm
70 mm
18 mm
100
Mounting holes 60 mm
Technical features:
LPD450F
LPD450F
Current input
Iin
Iin
0V
0V
L
W
Technical Data
0RXQWLQJVNHWFK
Input
Input current
Transmit function
Display
Type
Display value
Display range
Decimal point
General data
Supply voltage
Voltage drop
Accuracy
Repeat accuracy
Temperature coefficient
0RXQWLQJVNHWFK
4...20 mA
, x3/2, x5/2 or programmable (2-21 steps)
4.5-character, black LCD with clear background, 20 mm
Percentage or real value display
19.999 (0.00100.00 factory setting)
18888, 1.8888, 18.888, 188.88, 1888.8
Loop powered, via 4...20 mA input
< 4.3 V
0.05 % from signal range 1 digital step
0.01 % of signal range
3LSHPRXQWEUDFNHWFDQ
Offset 0.01 % / C
adjustment range 0.1 digital steps orEHWWHGWRVXLWDYHUWLFDO
0.01 % / C
RUKRUL]RQWDOSLSH
10...90 % (no condensation)
PP
Programmable in 99 steps from 1...30 sec.
16 x pro s
2 x per sec.
0 C...+60 C / -25 C...+70 C
DIN EN 61326
Screw connection
1.5 / 0.5 / 2.5
65 / 140 / 80
CE; cULus; cULusEX; GOSTME25
Humidity
Step response time
Sampling rate
Change of display
Ambient temperature / Storage temperature
EMC standards
Dimensions
Clamping range (nominal / min. / max.) (mm)
Length x width x height (mm)
Approvals
3LSHPRXQWEUDFNHWFDQ
EHWWHGWRVXLWDYHUWLFDO
RUKRUL]RQWDOSLSH
PP
Ordering Data
Current input
Note:
Type
LPD450F 4-20mA
Qty.
1
Part No.
7940010236
Fixing clip
Pipe Mount Kit - 7940010667
101
102
CP SNT 24W
LISTED
Technical Data
Input voltage
Minimum
Typical
Maximum
at 115 VAC
at 230 VAC
at 125 VDC
at 250 VDC
Fuse
Inrush current
Overvoltage protection
Input current
(Average values for reference only)
Input Protection
Switching frequency
Efficiency at maximum load
Maximum ripple
Regulation
Overload protection
Maximum capacitance at output
Hold time output current following input loss)
(Maximum
Temperature
Humidity
Galvanic isolation
Dimensions
Wire size
Dimensions (L x W x H)
Weight
Mounting position
Clearance
Approvals
Ordering Data
Output voltage/maximum current
at 115 VAC
at 230 VAC
Storage
Operating
Operating temperature
Storage temperature
Input-output
Input/output to mounting rail
Input to ground
Output to ground
Part No.
9928890024
9928890028
9928890015
9928890012
9928890005
103
L (+)
N(-
115VAC/230VAC autoselect
85-132/187-264 VAC autoselect
(output current derating below 100VAC)
47Hz - 63Hz
EN 61000-3-2, Class A (for limited output power)
20ms min. 115/230 VAC
<12A @ 115VAC; <20A @ 230VAC
6A
115VAC/230VAC autoselect
85-132/187-264 VAC autoselect
(output current derating below 100VAC)
47Hz - 63Hz
EN 61000-3-2, Class A (for limited output power)
20ms min. 115/230 VAC
<13A @ 115VAC; <25A @ 230VAC
6A
115VAC/230VAC autoselect
85-132/187-264 VAC autoselect
(output current derating below 100VAC)
47Hz - 63Hz
EN 61000-3-2, Class A (for limited output power)
20ms min. 115/230 VAC
<12A @ 115VAC; <20A @ 230VAC
6A
87% typ.
87% typ.
87% typ.
12 VDC
12-14 VDC
6.5A
70W
0.5 % max.
0.5 % max.
100 mV pk-pk typ. (200 mV pk-pk max. at Imax)
Current limitation at Imax., constant current,
automatic recovery
20V
electronic overload protection
Switch off at overtemperature, automatic restart
Dual color LED (green: DC ok; red: DC off)
911 V
11.0 V 1.0 V (20 mA max.)
rated: 30 VDC/1.0 A
12 VDC
12-14 VDC
13.0A
140W
0.5 % max.
0.5 % max.
100 mV pk-pk typ. (200 mV pk-pk max. at Imax)
Current limitation at Imax., constant current,
automatic recovery
20V
electronic overload protection
Switch off at overtemperature, automatic restart
Dual color LED (green: DC ok; red: DC off)
911 V
11.0 V 1.0 V (20 mA max.)
rated: 30 VDC/1.0 A
24 VDC
24-28 VDC
3.75A
90W
0.5 % max.
0.5 % max.
100 mV pk-pk typ. (200 mV pk-pk max. at Imax)
Current limitation at Imax., constant current,
automatic recovery
35V
electronic overload protection
Switch off at overtemperature, automatic restart
Dual color LED (green: DC ok; red: DC off)
18-22 V
22.0 V 2.0 V (10 mA max.)
rated: 30 VDC/1.0 A
AC
PE
DC
Technical Data
Input Specifications
Input voltage
Input voltage range
Ordering Data
104
Type
CP T SNT 70W 12V 6A
Part No.
1105430000
Type
CP T SNT 140W 12V 12A
Part No.
1105440000
Type
CP T SNT 90W 24V 3.8A
Part No.
1105790000
L (+)
N(-
115VAC/230VAC autoselect
85-132/187-264 VAC autoselect
(output current derating below 100VAC)
47Hz - 63Hz
EN 61000-3-2, Class A (for limited output power)
20ms min. 115/230 VAC
<13A @ 115VAC; <25A @ 230VAC
6A
115VAC/230VAC autoselect
85-132/187-264 VAC autoselect (output current
derating below 100VAC)
47Hz - 63Hz
EN 61000-3-2, Class A (for limited output power)
20ms min. 115/230 VAC
<16A @ 115VAC; <25A @ 230VAC
10A
115VAC/230VAC autoselect
85-132/187-264 VAC autoselect (output current
derating below 100VAC)
47Hz - 63Hz
EN 61000-3-2, Class A (for limited output power)
20ms min. 115/230 VAC
<25A @ 115VAC; <30A @ 230VAC
15A
87% typ.
87% typ.
87% typ.
24 VDC
24-28 VDC
7.5A
180W
0.5 % max.
0.5 % max.
100 mV pk-pk typ. (200 mV pk-pk max. at Imax)
Current limitation at Imax., constant current,
automatic recovery
35V
electronic overload protection
Switch off at overtemperature, automatic restart
Dual color LED (green: DC ok; red: DC off)
18-22 V
22.0 V 2.0 V (20 mA max.)
rated: 30 VDC/1.0 A
24 VDC
24-28 VDC
15A
360W
0.5 % max.
0.5 % max.
100 mV pk-pk typ. (200 mV pk-pk max. at Imax)
Current limitation at Imax., constant current,
automatic recovery
35V
electronic overload protection
Switch off at overtemperature, automatic restart
Dual color LED (green: DC ok; red: DC off)
18-22 V
22.0 V 2.0 V (20 mA max.)
rated: 30 VDC/1.0 A
24 VDC
24-28 VDC
25A
600W
0.5 % max.
0.5 % max.
100 mV pk-pk typ. (200 mV pk-pk max. at Imax)
Current limitation at Imax., constant current,
automatic recovery
35V
electronic overload protection
Switch off at overtemperature, automatic restart
Dual color LED (green: DC ok; red: DC off)
18-22 V
22.0 V 2.0 V (20 mA max.)
rated: 30 VDC/1.0 A
AC
PE
DC
Technical Data
Input Specifications
Input voltage
Input voltage range
Ordering Data
Type
CP T SNT 180W 24V 7.5A
Part No.
1105810000
Type
CP T SNT 360W 24V 15A
Part No.
1105820000
Type
CP T SNT 600W 24V 25A
Part No.
1105840000
105
AC
PE
DC
Technical Data
Input Specifications
Input voltage
Input voltage range
115VAC/230VAC autoselect
85-132/187-264 VAC autoselect (output current
derating below 100VAC)
47Hz - 63Hz
EN 61000-3-2, Class A (for limited output power)
20ms min. 115/230 VAC
<13A @ 115VAC; <25A @ 230VAC
6A
115VAC/230VAC autoselect
85-132/187-264 VAC autoselect (output current
derating below 100VAC)
47Hz - 63Hz
EN 61000-3-2, Class A (for limited output power)
20ms min. 115/230 VAC
<16A @ 115VAC; <25A @ 230VAC
10A
115VAC/230VAC autoselect
85-132/187-264 VAC autoselect (output current
derating below 100VAC)
47Hz - 63Hz
EN 61000-3-2, Class A (for limited output power)
20ms min. 115/230 VAC
<25A @ 115VAC; <30A @ 230VAC
15A
87% typ.
87% typ.
87% typ.
48 VDC
48-56 VDC
4.0A
180W
0.5 % max.
0.5 % max.
100 mV pk-pk typ. (200 mV pk-pk max. at Imax)
Current limitation at Imax., constant current,
automatic recovery
60V
electronic overload protection
Switch off at overtemperature, automatic restart
Dual color LED (green: DC ok; red: DC off)
36-46 V
44.0 V 4.0 V (15 mA max.)
rated: 48 VDC/0.5 A
48 VDC
48-56 VDC
7.5A
360W
0.5 % max.
0.5 % max.
100 mV pk-pk typ. (200 mV pk-pk max. at Imax)
Current limitation at Imax., constant current,
automatic recovery
60V
electronic overload protection
Switch off at overtemperature, automatic restart
Dual color LED (green: DC ok; red: DC off)
36-46 V
44.0 V 4.0 V (15 mA max.)
rated: 48 VDC/0.5 A
8 VDC
48-56 VDC
12.5A
600W
0.5 % max.
0.5 % max.
100 mV pk-pk typ. (200 mV pk-pk max. at Imax)
Current limitation at Imax., constant current,
automatic recovery
60V
electronic overload protection
Switch off at overtemperature, automatic restart
Dual color LED (green: DC ok; red: DC off)
36-46 V
44.0 V 4.0 V (15 mA max.)
rated: 48 VDC/0.5 A
Ordering Data
Type
CP T SNT 180W 48V 4A
106
Part No.
1105850000
Type
CP T SNT 360W 48V 7.5A
Part No.
1105860000
Type
CP T SNT 600W 48V 12.5A
Part No.
1105870000
Redundancy Modules
With a redundancy module
and two PRO-H Series
power supplies (of same
type) you can configure a
highly reliable, truly redundant power system without
any additional components.
This module enforces the
equivalent sharing of the
output current by each power
supply. The system
is fully redundant and
provides output power even
if one power supply has
completely failed e.g. by short
circuit on the output.
In the event that either
power supply fails or is
disconnected, the second
unit will automatically supply
the full current to the load.
The redundancy of the
system is monitored and if
lost, indicated by an alarm
output. The inputs are hot
swappable and can be
loaded up to 15A each.
CP T RM 10
Redundancy Module
CP T RM 20
Redundancy Module
Technical Data
Input Specifications
Input
Input current
Output Specifications
Output voltage
Output voltage adj. range
Output power max.
Output current
General Data
Status indicator
Operating temperature
2 x 24 VDC
15A
2 x Control Input
25A
Diagram
24Function
VDC
24-27 VDC
360 W
+ J1.2
15A @ 24VDC,
DC @
IN 140C
_
24 VDC
24-27 VDC
600 W
J2.3
J2.4 +
25A @ 24VDC, @Output
40C
J2.1
J2.2
J1.1
Load
J3.1
LED
LED
J3.2
TSP
25 C
to 70 Remote
C max. (13 F...+158 F)
25 C to 70 C max. (13 F...+158 F)
Link 1
derating above 40 C (104 F): 1.5 %/K
derating above 40 C (104 F): 1.5 %/K
Volt adjust
J1.4
trigger threshold at +18...22VDC,
trigger threshold at 18...22VDC, contact open if
IN 2_ inputs failed
contact open ifDCboth
both inputs failed
J1.3
>350,000 hours, max. load
>350,000 hours, max. load
J4.1
30VDC/1A
REM Controller
J4.2
Remote1055Hz,
3 axis,TSP
3 axis, sine sweep, 1055Hz, 1g, 1oct/min.
sine sweep,
1g, 1oct/min.
Link 2
3 Power
axis, 15g half sine, 11ms
3 axis, 15g half sine, 11ms
Supplies
35 x 110 x 110 mm
54 x 110 x 110 mm
Redundancy
ok
0.5kg
0.7kg
J5.1
J5.2
J5.3
J5.4
Alarm
Remote On/Off
2 cables included
2 cables included
by ext. contact: contact open = On,
by ext. contact: contact open = On,
contact closed = Off
contact closed = Off
II 3G Ex nA nC IIC t4 Gc
Ordering Data
Type
CP T RM 10
Function Diagram
+
TSP
Front view
J1.2
J1.1
Power
Supplies
Part No.
1105890000
J2.1
J2.2
Bottom view
Top view
1 2 3 4
Output
Load
1
2
1
2
Volt adjust
J1.4
J4
J3
J1.3
J4.1
Remote
Link 2
Type
CP T RM 20
Output
Remote
Link 1
DC IN 2_
TSP
J2
J2.3
J2.4
J3.1
J3.2
Part No.
1105880000
Connector Positions
Connector Positions
Function Diagram
DC IN 1_
II 3G Ex nA nC IIC t4 Gc
J5
REM Controller
J4.2
DC IN 1 DC IN 2
J5.1
Redundancy
ok
J5.2
Alarm
J5.3
J5.4
J1
Remote On/Off
1 2 3 4
J3
J4
J1
J2
Voltage Control 1
Voltage Control 2
J5
For Input 1
For Input 2
Pin 1
Input 1-Vin
GND (-)
S+
S+
DC-OK Signal
Pin 2
Input 1+Vin
GND (-)
S-
S-
DC-OK Relay Contact
Pin 3
Input 2-Vin
Vout (+)
-
-
Remote ON/OFF
Pin 4
Input 2+Vin
Vout (+)
-
-
Remote ON/OFF
Connector Positions
Front view
1 2 3 4
Bottom view
Top view
107
CP SNT 55W
CP SNT 160W
Approvals:
LISTED
Technical Data
Input Voltage
Minimum
Typical
Maximum
at 115 VAC
at 230 VAC
at 125 VDC
at 250 VDC
Fuse
Inrush Current
Overvoltage
Input current
(Average values for reference only)
Input protection
Switching frequency
Efficiency at maximum load
Maximum ripple
Regulation
Overload protection
Output surge capability
Maximum capacitance at output
Parallel connection for load sharing
Hold time
(Maximum output current following input loss)
Temperature
Humidity
Galvanic isolation
Wire size
Dimensions (L x W x H)
Weight
Mounting position
Clearance
at 115 VAC
at 230 VAC
Storage
Operating
Operating temperature
Storage temperature
Input-output
Input/output to mounting rail
Input to ground
Output to ground
30 ms
180 ms
-40C+85C (-40F+185F)
-20C+50C (-4F+122F) full rated load
Derating: 24 V-1.5 A at 60C (140F)
2085% RH non-condensing
2090% RH
3 kV RMS
3 kV RMS
1.5 kV RMS
500 V RMS
0.14.0 mm2 (2612 AWG)
98 x 57 x 131 mm (3.86 x 2.24 x 5.16 in.)
478 g (1.05 lbs.)
Horizontal on mounting rail TS35, Chassis
20 mm left and right
30 mm above and below if next to non-heat producing
(low-power) module
60 mm above and below if next to high heat producing module,
(i.e. another power supply)
Fault relay
Approvals/Certifications
Ordering Data
Accessories
Chassis Mounting Kit
Side mount BracketDIN rail
108
Type
CP SNT 55W
24 VDC-28 VDC / 2.3 A
48 VDC / 1.04 A
12 VDC - 15 VDC / 3 A
5 VDC / 3 A
Type
CP SNT 160W
24 VDC-28 VDC / 6.5 A
5 VDC / 10 A
12 VDC / 10 A
48 VDC / 3.25 A
Part No.
9927480024
9927480048
9927480012
9927480005
Part No.
7920560000
Part No.
9925340024
9925340005
9925340012
9925340048
Part No.
7920560000
7940000542
CP SNT 300W
Approvals:
LISTED
Technical Data
Input voltage
Switching frequency
Efficiency
Output ripple
Regulation
Protection
Minimal
Typical
Maximum
at 115 VAC
at 230 VAC
at 100 VDC
at 200 VDC
Fuse
Inrush current
Overvoltage
at max.load
Load (10-100%) Line (86-265
VAC RMS)
Overvoltage
Undervoltage
Overload
Output surge capability
Thermal
LED indicator
Shut down
The 300 W power supply offers the following additional functions
Galvanic isolation
Dimensions (L x W x H)
Weight
Mounting position
Clearance
Approvals/Certifications
at 115 VAC
at 230 VAC
Storage
Operating
Derating
Input-output
Input/output to mounting rail
Input to ground
Output to ground
Ordering Data
Type
CP SNT 300W
Accessories
Chassis Mounting Kit
Part No.
9916250024
Part No.
7920560000
109
connectPowerDC-DC Converters
connectPowerDC-DC Converters
DC to DC converters enable customers
to derive low voltage DC signals from
either 12 VDC or 24 VDC sources.
They are typically connected at the
output of a DC power source and can
deliver DC voltages of 5, 12, 15 or 24
volts. DC voltage converters (DC to DC
converters) are intended in particular
for the decentralized power supply of
circuits, assemblies and modules. DC
voltage converters are often required
for emergency generators to supply
electrical devices from batteries or
other DC systems.
DC-DC Converters
Remote Monitoring
SUN
Antenna
Antenna
Solar Cell
24VDC
I/O Devices
and Sensors
I/O 24VDC
Radio
Transmitter
12V (powered)
12VDC
+
+ OUTPUT
-
SCADA System
or Other Type
of Control System
15VDC
3A
V out Adjust
DC ON
+
-
INPUT
12VDC 15%
2.37A 15%
24VDC
REMOTE MONITORING
110
connectPowerDC-DC Converters
CP-DCDC 50W
12 VDC Input
CP-DCDC 50W
24 VDC Input
12 VDC
10.2 VDC
12 VDC
16 VDC
4.53 A
3.88 A
4.7 A
4.96 A
internal (not user serviceable) 2 A
180 kHz PWM
80% (75% 5 VDC @8 A)
0.2% RMS
Overvoltage switch-off with automatic reset/short circuit
10,000 F (8000 F 5 VDC @8 A)
2.5 mS
3.8 mS
3.5 mS
3.5 mS
-40C+85C (-40F+185F)
-10C+50C (+14F+122F) full rated load
2085% RH
2090% RH non-condensing
500 VAC RMS
4 KV RMS
500 VAC RMS
500 VAC RMS
0.14.0 mm2 (2612 AWG)
98 x 57 x 131 mm (3.86 x 2.24 x 5.16 in.)
454 g (1 lb.)
Horizontal on mounting rail TS35, Chassis w/ optional kit
20 mm left and right
30 mm above and below if next to non-heat producing
(low-power) module
60 mm above and below if next to high heat producing module,
(i.e. another power supply)
24 VDC
18 VDC
24 VDC
30 VDC
2.3 A
1.93 A
2.37 A
2.49 A
internal (not user servicable) 2 A
330 kHz PWM
80% (75% 5 VDC @8 A)
0.2% RMS
Overvoltage switch-off with automatic reset/short circuit
8000 F
7.8 mS
10 mS
7 mS
7 mS
-40C+85C (-40F+185F)
-10C+50C (+14F+122F) full rated load
2085% RH
2090% RH non-condensing
500 VAC RMS
4 KV RMS
500 VAC RMS
500 VAC RMS
0.14.0 mm2 (2612 AWG)
98 x 57 x 131 mm (3.86 x 2.24 x 5.16 in.)
454 g (1 lb.)
Horizontal on mounting rail TS35, Chassis w/ optional kit
20 mm left and right
30 mm above and below if next to non-heat producing
(low-power) module
60 mm above and below if next to high heat producing module,
(i.e. another power supply)
CSA, UL Listed, CE
CSA Class 1 Div. 2 and Zone 2
r v %
Technical Data
Input Voltage
Input protection
Switching frequency
Efficiency at maximum load
Maximum ripple
Overload protection
Maximum capacitance at output
Hold time
Temperature
Humidity
Galvanic isolation
Wire size
Dimensions (L x W x H)
Weight
Mounting position
Clearance
Approvals/Certifications
Ordering Data
Output voltage/maximum current
Accessories
Chassis Mounting Kit
L Bracket Mounting KitPanelmount
Minimum
Typical
Maximum
5 VDC @8A
12 VDC @3A
15 VDC @3A
24 VDC @2A
Fuse
5 VDC @8A
12 VDC @3A
15 VDC @3A
24 VDC @2A
Storage
Operating
Operating temperature
Storage temperature
Input to output
Input/output to rail
Input to ground
Output to ground
Type
CP-DCDC 50W
22 - 24 VDC @ 2 A
15 VDC @ 3 A
12 VDC @ 3 A
5 VDC @ 8 A
Part No.
9919371224
9919371215
9919371212
9919371205
Part No.
7920560000
7940000543
Type
CP-DCDC 50W
22-24 VDC @ 2 A
15 VDC @ 3 A
12 VDC @ 3 A
5 VDC @ 8 A
Part No.
9919372424
9919372415
9919372412
9919372405
Part No.
7920560000
7940000543
111
LOADS
Battery Back Up
Power Supply
BATTERY +
Battery
BATTERY EXT. PS +
LOAD +
LOAD +
LOAD -
991628 0024
24VDC BATTERY
BACK-UP UNIT
r
CLASS 1, DIVISION 2
GROUPS A, B, C &D T4A
SEE SIDE PANEL
EXT. PS -
LOAD -
CHARGING
FULL CHARGE
BATTERY
OPEN
BATTERY
LOW
BATTERY
REVERSE
FAULT
+ ENABLE
+ DRAIN
+ DRAIN
RESET
- COM
BAT
STATUS
MAX. 1A
@30VDC
FAULT
RELAY
MAX. 1A
@30VDC
L
AC IN
g B.B.U.
N
L
AC OUT
g EXT. PS
N
LGN
BBU AC IN
112
DC OUTPUT
15A MAX.
LISTED
9ZX0
PS AC INPUT
AC INPUT
BBU
12 VDC Input
BBU
24 VDC Input
85 VAC
115-230 VAC 10%
265 VAC
0.8 A
0.5 A
2 A slow blow (internal, not user serviceable)
Thermistor 40 A maximum
Varistor
12 VDC syst.
15 A maximum
20 A max for 300 mS
30 A max for 100 mS
12-14 VDC
10 A maximum
< 0.5 mS
Limited by internal 4.0 A fuse
16 V
9.3 V
120C (248F) 10%
Continuous
Continuous
-20C+85C (-4F+185F)
-20C+50C (-4F+122F)
2090%
2085% non-condensing
3 KV
3 KV
1.5 KV
500 V
0.14 mm2 (2612 AWG)
0.51.5 mm2 (2814 AWG)
127.5 x 72.5 x 161 mm (5.02 x 2.85 x 6.34 in.)
950 g (2.09 lbs.)
dry contact/open collector
dry contact/open collector
dry contact/open collector
Form C Relay and LED
Form C Relay and LED
3.0 A
Regulates to 13.65 V
LED
LED
Yellow LED on below 11 V
4 AH
scalable
Horizontal on mounting rail TS35 (optional direct panel mount)
20 mm left and right
30 mm above and below if next to non-heat producing (low-power)
module
60 mm above and below if next to high heat producing module, (i.e.
another power supply)
plug and socket
85 VAC
115-230 VAC 10%
265 VAC
1.0 A
0.6 A
2 A slow blow (internal, not user serviceable)
Thermistor 40 A maximum
Varistor
24 VDC syst.
15 A maximum
20 A max for 300mS
30 A max for 100mS
24-28 VDC
10 A maximum
< 0.5 mS
Limited by internal 4.0 A fuse
32 V
18.3 V
120C (248F) +10%
Continuous
Continuous
-20+85C (-4F+185F)
-20+50C (-4F+122F)
2090%
2085% non-condensing
3 KV
3 KV
1.5 KV
500 V
0.14 mm2 (2612 AWG)
0.51.5 mm2 (2814 AWG)
127.5 x 72.5 x 161 mm (5.02 x 2.85 x 6.34 in.)
950 g (2.09 lbs.)
dry contact/open collector
dry contact/open collector
dry contact/open collector
Form C Relay and LED
Form C Relay and LED
2.0 A
Regulates to 27.3V
LED
LED
Yellow LED on below 22 V
4 AH
scalable
Horizontal on mounting rail TS35 (optional direct panel mount)
20 mm left and right
30 mm above and below if next to non-heat producing (low-power)
module
60 mm above and below if next to high heat producing module, (i.e.
another power supply)
plug and socket
Type
BBU 12 VDC
Type
BBU 24 VDC
r v %
Technical Data
Input Voltage
Input current
Input protection
Output to Load
Minimum
Typical
Maximum
at 115 VAC
at 230 VAC
Fuse
Input current
Overvoltage
Voltage Nominal
Load Current
Surge Current from no load
Load voltage
AC input current
Switching time from external PS to battery
Protection
Battery Polarity Protection
Battery Overvoltage
Battery Undervoltage
BBU Over Temperature Shutdown
Charger Short Circuit
Load Short Circuit
Temperature
Storage
Operating
Humidity
Storage
Operating
Galvanic Isolation
Input to output
Input/output to rail
Input to ground
Output to ground
Wire Size
Power Connections
Control inputs/relay outputs
Dimensions (L x W x H)
Weight
Control inputs
Enable
Status outputs
Drain
Drain Reset
Battery Status
Fault
Battery Charger
Charge Current
Full Charge
Battery Reverse
Battery Open
Battery Low
Battery Capacity
Minimum
Maximum
Mounting position
Clearance
Connections
Approvals/Certifications
Ordering Data
Accessories
Chassis Mounting Kit
Part No.
9916280012
Part No.
7920560000
Part No.
9916280024
Part No.
7920560000
113
Functional Outline
The BBU is at its basic level a scalable
UPS for 12 VDC or 24 VDC power. It
is the heart or center of the system
with everything wired through it. In
this way it can monitor the status of
the AC mains, the AC to the power
supply, the DC out of the power
supply and the battery condition. The
BBU does NOT have built-in batteries.
The batteries are sized based on the
current and time demand for the
back-up power.
The typical system is comprised of
the following: the BBU, the battery
pack and the power supply. The
power supply is sized as per normal
requirements (how much current is
needed). The batteries are sized based
Digital Inputs
Diagnostic LEDs
Enable:
A connection between the Enable
and COM terminals enables the
BBU. If terminals are open circuit
(Disabled), the BBU functions as a
battery charger only. In the event
of AC failure the batteries are not
connected to the load via the BBU.
The BBU is factory preset as Enabled.
Drain:
A temporary short between the
Drain and COM terminals switches
the load to the batteries until the
battery voltage reaches 11/22V. At
this point the AC power is returned to
the power supply and the BBU starts
recharging the batteries. The Drain
cycle can also be reset / terminated
by activating the Drain Reset input.
Drain Reset:
A temporary short between the Drain
Reset and COM terminals disables
the Drain cycle to the batteries.
114
Relay Outputs
Bat Status:
Battery status, this changes state
based on whether the batteries
are charging or fully charged.
See Diagnostic LEDs (Full Charge,
Battery Low and Full Charge) for
more detailed information.
Fault Relay:
De-energizes under a fault condition.
See Diagnostic LEDs (Fault LED,
Battery Reverse, and Battery Open)
for more detailed information.
Typical Schematic
The 15A Critical Load limit is a limit of
the BBU itself and not the power supply.
This schematic is representative of a
24 VDC system. For a 12 VDC system
use a 12 VDC battery pack, a 12 VDC
power supply and a 12 V BBU, part
number 991628 0012.
The fuses may be replaced by another
means of circuit protection, i.e. circuit
breakers.
It is recommended to monitor the
power supply Fault/Status relay/output
if available.
The power supply shown is for illustration purposes only. The power supply
needs to be chosen based on load
requirements.
115
US
116
Approvals
Technical Data
Authority
Voltage rating
UL2367 (E306740)
24VDC
UL1604 (E322549) (class 1, div. 2, group
24VDC
A, B, C, D)
UL508/ cUL 508
24VDC
24VDC
CSA file 165971:
CSA C22.2 No: 213 (class I, div. 2)
Groups A, B, C, D, T5
CSA C22.2 No: 142
24VDC
Class 2
Meets requirements for Class 2 current limitation
(ESX10-T... 0.5 A / 1 A / 2 A / 3 A
Technical Data
Current ratings
0.5...12 A
0.5...12 A
0.5...12 A
0.5...12 A
0.5...12 A
Operating data
Operating voltage Ub
Current rating In
Closed current I0
Status indication by means of
24VDC (18...32 V)
fixed current ratings: 0.5, 1 A, 2 A, 3 A, 4 A,
6 A, 8 A, 10 A, 12 A
ON condition: typically 20...30 mA
depending on signal output
multicolor LED:
GREEN: - unit is ON, power-MOSFET
- is switched on
- status output SF ON,
- supplies + 24VDC
ORANGE: in the event of overload or
short circuit until electronic
disconnection
RED:
- unit electronically disconnected
- load circuit/Power-MOSFET
OFF
OFF:
Temperature disconnection
Low voltage monitoring
load output
Starting delay tstart
Disconnection of load circuit
Free-wheeling circuit
Several load outputs must not be connected in parallel
117
Technical Data
General data
Fail-safe element:
Terminals
screw terminals
max. cable cross section
flexible with wire end ferrule w/wo plastic sleeve
multi-lead connection
(2 identical cables)
rigid/flexible
flexible with wire end ferrule without plastic sleeve
flexible with TWIN wire end ferrule with plastic sleeve
wire stripping length
tightening torque (EN 60934)
Terminals
screw terminals
max. cable cross section
flexible with wire end ferrule w/wo plastic sleeve
wire stripping length
tightening torque (EN 60934)
Housing material
active current
max. load current at 100% ON duty
limitation (typically) Tu = 40 C
Tu = 50 C
1.8 x In 0.5 A
0.5 A
1.8 x In 1 A
1A
1.8 x In 2 A
2A
1.8 x In 3 A
3A
1.8 x In 4 A
4A
1.8 x In 6 A
5A
1.5 x In 8 A
7A
1.5 x In 10 A
9A
1.3 x In 12 A
10.8 A
Attention:when mounted side-by-side without convection the ESX10-T should not carry more than 80% of
its rated load with 100% ON duty due to thermal effects.
Mounting
Ambient temperature
Storage temperature
Humidity
Vibration
Degree of protection
EMC
(EMC directive, CE logo)
Insulation co-ordination
(IEC 60934)
dielectric strength
Insulation resistance
(OFF condition)
Approvals
Dimensions (W x H x D)
Mass
Please note:
The user should ensure that the cable cross sections of the relevant load circuit are suitable for the current
rating of the ESX10-T used.
Automatic start-up of machinery after shut down must be prevented (Machinery Directive 98/37/EG and
EN 60204-1). In the event of a short circuit or overload the load circuit will be disconnected electronically
by the ESX10-T.
Refer to UL/CSA file for proper wiring and installation techniques.
Table 2: Specifications
Protection
CE logo
UL
CSA
ATEX
Version
Signal input
Signal output
Signal contact
Status output
without
Control input
Remote
without
single signal
single signal
without
Status OUT
Status OUT
Signal
ON/OFF Reset
Reset
Signal
N/O
N/C
Signal
Positive 24V
V = OK
Input
Output
(normally open NO)
(normally closed NC)
Output
= OK
ESX10-TA-100 x x
x
ESX10-TB-101 x
x
x
ESX10-TB-102 x
x
x
ESX10-TB-114 x x
ESX10-TB-124 x x x
ESX10-TB-127 x x x
ESX10-TA-100
ESX10-TB-101
Circuit
Current
Protection
Rating
5 V Number
DC R
ampsVSPC 1CLPart
0.5
1
2
3
4
6
8
10
12
118
6720005305
6720005301
6720005302
6720005303
6720005304
6720005306
6720005308
6720005310
6720005312
ESX10-TB-102
ESX10-TB-114*
ESX10-TB-124**
ESX10-TB-127
Current
Rating
amps
Circuit
Protection
Part Number
Current
Rating
amps
Circuit
Protection
Part Number
Current
Rating
amps
Circuit
Protection
Part Number
Current
Rating
amps
Circuit
Protection
Part Number
Current
Rating
amps
Circuit
Protection
Part Number
0.5
1
2
3
4
6
8
10
12
6720005320
6720005321
6720005322
6720005323
6720005324
6720005326
6720005328
6720005330
6720005332
0.5
1
2
3
4
6
8
10
12
6720005340
6720005341
6720005342
6720005343
6720005344
6720005346
6720005348
6720005350
6720005352
0.5
1
2
3
4
6
8
10
12
6720005360
6720005361
6720005362
6720005363
6720005364
6720005366
6720005368
6720005370
6720005372
0.5
1
2
3
4
6
8
10
12
6720005380
6720005381
6720005382
6720005383
6720005384
6720005386
6720005388
6720005390
6720005392
0.5
1
2
3
4
6
8
10
12
6720005309
6720005319
6720005329
6720005339
6720005349
6720005369
6720005389
6720005399
6720005313
ESX10-TB-101
ESX10-TB-102
ESX10-TB-114
LINE+
LOAD+
LINE+
SF 23
13
11
IN 21
LOAD+
0V
ESX10-TB-127
LOAD+
0V
LOAD+
0V
Dimensions
ESX10-TB-124
SF 23
LINE+
12
LINE+
LINE+
14
0V
LINE+
12.5
.492
83
3.27
LINE
LINE
LOAD
LOAD
SF 23
RE 22
80
3.15
RE 22
LOAD+
0V
LOAD+
0V
80
3.15
operating condition: S F 0 V = O K
fault condition:
S F +24 V
label
mm
This is a metric design and millimeter dimensions take precedence ( )
inch
119
disconnection
typically 1.1 x I n 1.8 x I n *1)
10000
1000
100
10
5
1
0.1
0.01
0
5 IK
120
LINE+ busbar
6720005315
continuous busbar
500 mm length, cut
Up to 40 pole
signal bar
6720005316
or
jumper
6720005317
(2 pole only)
remove protection
against brush contact
located on bottom side
0V busbar
6720005315
insert busbars
and protection slides
to be flush with housing sides
insert signal
bars to be flush with
housing and place them
centrally over the contacts
5 ESX10-TB
with busbars
and jumpers
5 ESX10-TA
with busbars
Mounting procedure:
Before wiring insert busbars into protection block.
121
+ line entry
LINE+ busbar
1
LINE+
1
LINE+
1
LINE+
ESX10-TA-100
ESX10-TA-100
ESX10-TA-100
+24V
power suppl y
DC 24 V
0V
2 LOAD+
2 LOAD+
2 LOAD+
3 0V
3 0V
3 0V
0 V busbar
- line entry
-
+
load
ESX10-TA-100
+
load
load
ESX10-TB-101
ESX10-TB-101
ESX10-TA-100
ESX10-TB-102
terminals for
busbars
screw
terminals
+ line entry
+ line entry
LINE+ busbar
1
LINE+
1
LINE+
+24V
LINE + busbar
1
LINE+
+ line entry
for the S I
13
+24V
+ line entry
power suppl y
DC 24 V
ESX10-TA-100
ESX10-TA-100
ESX10-TA-100
2 LOAD+
2 LOAD+
2 LOAD+
3 0V
3 0V
3 0V
11
13
1
LINE+
ESX10-TB-101
1
LINE+
ESX10-TB-101
3 0V
3 0V
12 11
2 LOAD+
0V
power supply
DC 24 V
0 V busbar
14
1
LINE+
+
load
load
12
2 LOAD+
1
LINE+
ESX10-TB-101
jumpers ar e staggered
12
2 LOAD+
11
3 0V
- line entry
+
load
13
ESX10-TB-102
ESX10-TB-102
- line entry
14
1
LINE+
group signalling
by means of an LED
LINE+ busbar
power supply
DC 24 V
+24V
0V
1
LINE+
0V
load
2 LOAD+
3 0V
+
load
ESX10-TB-102
2 LOAD+
3 0V
+
load
2 LOAD+
3 0V
0 V busbar
- line entry
+
ESX10-TB-101
load
load
load
ESX10-TB-124
Single signalling with common reset
ESX10-TB-124
ESX10-TB-102
ESX10-TB-102
+ line entry
LINE + busbar
LINE+
13
14
1
LINE+
13
14
1
LINE+
13
group signalling
single
signalling
per way
by
means
of an LED
by means of an LED
+ line entry
for the S I
power supply
DC 24 V
+ line entry
jumpers ar e staggered
2 LOAD+
2 LOAD+
2 LOAD+
1
3 0V
LINE+
1
3 0V
LINE+
1
3LINE+
0V
12
12 11
11
entry
power- line
supply
DC 24 V
load
ESX10-TB-102
0V
ESX10-TB-101
ESX10-TB-101
ESX10-TB-101
0V
+24V
14
load
ESX10-TB-102
+ line entry
LINE+ busbar
LINE+ busbar
22
0V busbar
1
LINE+
1
LINE+
+24V
12
11
reset
button
RE
SF
23
ESX10-TB-124
2 LOAD+
2 LOAD+
3 0V
3 0V
3 0V
RE
SF
23
22
RE
SF
0V
ESX10-TB-124
ESX10-TB-124
2 LOAD+
2 LOAD+
2 LOAD+
3 0V
3 0V
3 0V
0 V busbar
- line entry
+
load
load
load
ESX10-TB-124
Single signalling with common reset
reset
button
+ line entry
LINE+ busbar
1
LINE+
1
LINE+
+24V
22
RE
SF
23
22
RE
SF
1
LINE+
23
22
RE
SF
23
power supply
DC 24 V
ESX10-TB-124
0V
ESX10-TB-124
ESX10-TB-124
2 LOAD+
2 LOAD+
2 LOAD+
3 0V
3 0V
3 0V
0V busbar
- line entry
+
load
122
+
load
+
load
0V busbar
- line entry
load
23
power supply
DC 24 V
load
ESX10-TB-102
2 LOAD+
22
1
LINE+
+
load
+
load
6720005316
6720005317
2.5
.099
2.5
.099
tinned copper
9102100000
50 pin lugs to
DIN 46230
tinned copper
~70
~2.76
Part No.
6720005315
~70
~2.76
Description
Busbars for LINE+ and 0 V
max. load with one line entry
50 A
(recommended: centre line entry) Imax
max. load with two line entries Imax
63 A
length:
500 mm
~70
~2.76
Description
The ESX10-T features an integral power distribution system.
The following wiring modes are possible with various pluggable current and
signal busbars:
LINE +(24VDC)
0 V
Caution: The electronic devices ESX10-T require a 0 V connection
Signal contacts
Reset inputs
2.5
.099
Imax
50A
AD-TXEM01
123
MA15 Series
AC & DC Power Protection
Product Features:
Range of ATEX Certified intrinsically safe surge protectors
Ultra-slim and space saving designs; easy installation
Multistage hybrid protection circuitry - 20kA maximum
surge current
Range of voltage ratings ideal for process I/O applications
Designed for high bandwidth, low resistance applications;
RTD, Public Switch Telephone Network (PSTN) and 3-wire
transmitter versions available in SD Series
Surge protection for two loops or one 4-wire circuit per
SLP Series module
10 year product warranty
Product Features:
TP48 Series
Transmitter and Sensor Protection
124
SD Series
SLP Series
Modules with a
comprehensive range of
voltage ratings cover all
process related signals
such as RTDs, Thermocouples (THCs), 4 - 20mA loops, telemetry outstations,
shut-down systems and fire and gas detectors.
The optional loop disconnect featured on the SD07,
SD16, SD32 and SD55 modules allows users to perform
commissioning and maintenance without removing the surge
protection device. In addition, a third connection on the field
and safe side of the module is provided for safe termination
of shields.
For three wire applications the specially designed SDRTD
(Resistance Temperature Detector) and the SD32T3,
(for separately powered 4 - 20mA loops) provide full
3-wire protection in a single compact unit. The SD07R3
provides protection of 3-wire pressure transducers on low
power circuits.
For higher bandwidth applications, the SDR Series
meets the demands of todays highest speed
communication systems.
120V and 240V AC versions are available for I/O and power
supplies up to three Amps of load current and telephone
networks can be protected by the SDPSTN.
All modules are DIN-rail mountable on a TS-35 rail.
A comprehensive range of mounting and grounding
accessories are available.
125
Field Circuit
Bulk
PSU
1 Up to 50V dc
4/20mA
1 to 5V
2
TP48
transmitter
protector
5
6
3
SD32
SD55
SD32X
SD55X
(no fuse)
Multiple
Loops
2-wire transmitters
SDRTD
1
Recorder
Controller
Computer
etc.
3
SDRTD
3-wire RTDs
2xSD07X
or 2xSD16X
Signal
5
mV source
Turbine
Flowmeter
3
SD07
SD16
photocells,
thermocouples (THCs), mV
sources and
turbine flowmeters
126
Photocell
Thermocouple (THC)
SD07X
SD16X
(no fuse)
Protected Circuit
Field Circuit
2xSD15X, SD32X
Analog outputs
OV
3
SD16
SD32
SD35
SD16
SD32X
SD55X
(no fuse)
Controller outputs
(I/P converters)
SD
V
2
Logic Signal
3
SD07
SD16
SD32
SD55
SD07X
SD16X
SD32X
SD55X
OV
(no fuse)
Switches
SD32X
LED
Alarm
32V max
2
3
SD32
SD32X
(no fuse)
Incoming
Telephone
Line
Modem,
fax or
telephone
Telecom line
110/120V ac
or
220/240V ac
5
6
PLC,
DCS,
SCADA,
etc.
2
3
127
To Host Circuit
4
4-20mA
5
6
3
Plant structure
SD16X
SD32X
SD55X
1
2
Plant structure
24V
5
4-20mA
6
Common OV
SD32T3
1
Plant structure
Supply OV
6
SD16X
SD32X
SD55X
128
Supply voltage
5
4-20mA
TP Protected
Field Circuit
TP48
2
1
TP48
3
5
1
Protected Field Circuit
4
5
46
3
2
SD32R
(no fuse)
2
4
13
SD32R
5
(no fuse)
6
SD32R
(no fuse)
2
3
SD32R
(no fuse)
TP48
TP48
2
1
4
5
SD32R
(no fuse)
6
3
2
3
SD32R
(no fuse)
Typical Applications
Table 1 shows suitable SD devices for different applications.
In some applications alternative devices may be used, for
example, where lower in-line resistance or a higher voltage
power supply is used.
MTL Surge Technologies has operationally tested the
recommended SD Series units with the representative
highways listed. However, no formal approval for their use in
these systems has been sought from the respective bodies.
Table 1
Application
Allen Bradley Data Highway Plus
Foundation Fieldbus
31.25kbits/s voltage mode
1.0/2.5 Mbits/s
HART
Honeywell DE
LonWorks
FFT-10
LPT-10
TP-78
IS78
Modbus & Modbus Plus (RS485)
PROFIBUS
DP
PA (IEC 1158, 31.25 kbits/s)
RS232
RS422
RS423
RS485
WorldRP (IEC 1158)
31.25 kbits/s voltage mode
1.0/2.5 Mbits/s
SD32, SD32R
SD32, SD32R
SD32R
SD55R
SD07R
SD32R
SD16R
SD32R
SD32R
SD16
SD07R
SD07R
SD07R
SD16X
SD32R
SD55R
129
Instrument
Instrument earth
Grounding
The recommended grounding for field-mounted devices
has been illustrated previously. The grounding at the control
panel is more critical as there are usually a number of
grounding systems, each with their own requirements.The
grounding system illustrated here replaces the instrument
0V bond, the control system PSU bond and the IS ground
with one single ground connection to meet all the design
requirements and give the most effective protection against
the effects of lightning induced surges.
Marshalling cabinet
Field cables
SPD
Electrical earth
Frame
connection
Floor void
System earth
To plant/neutral
star point
130
Protection
Full hybrid line to line
Each line to screen/ground
Max. discharge surge current (Imax) (8/20s)
20kA (8/20s)
6.5kA (SD150X and SD275X only)
Nominal discharge surge current (isn)
3kA (8/20s)
Lightning impulse current (Iimp) (10/350s)
2.8kA
1.0kA (SD150X and SD275X only)
Response time
<1ns
RTD resistance range (SDRTD)
10 to 1500
Degradation accuracy (SDRTD at 1mA)
0.1% (RTD resistance > 100)
0.1W (RTD resistance < 100)
Ambient temperature
40C to +80C/ -40F to 176F working
40C to +80C / -40F to 176F storage
For IS working applications:
Pi = 1.0W (30C to +75C / -22F to 167F)
Pi = 1.2W (30C to +60C / -22F to 140F)
Pi = 1.3W (30C to +40C / -22F to 104F)
Humidity
5 to 95% RH (non-condensing)
Category tested
A2, B2, C1, C2, C3
Overstressed fault mode In=3kA
12kA
9kA (SD150X and SD275X only)
Impulse durability (8/20s)
10kA
6.5kA (SD150X and SD275X only)
Terminals
2.5mm2 (12 AWG)
Mounting
T-section DIN-rail 35 x 7.5 or 35 x 15mm rail
(1.38 x 0.3 x 0.6)
Weight
70g approximately (2.5oz)
Case flammability
UL94 V-2
AC durability
1Arms, 5T
Service conditions
80kPa - 160kPa
5% - 95% RH
EMC compliance
To Generic Immunity Standards,
EN 61326-1, part 2 for industrial
environments
R&TTE compliance
EN 41003:1999
EN 60950-1:2006
(not applicable to SD150X and SD275X)
LVD compliance
SD150X & SD275X
EN 60950-1:2006
EN 61010:2010
SDPSTN
EN 41003:1999
IEC compliance
EN 61643-21:2001
ANSI/IEEE testing
C62.41-1-2002
C62.41-2-2002
C62.45-2002
Approvals
(Authority)
Standard
Certificate/File No.
Approved for
Product
Country
Baseefa [ATEX]
EN 60079-0:2009
Baseefa02ATEX0211X
Ex ia IIC T4 Ga
SD07X, SD16X, SD32X, SD55X, SD07R,
(EU)
EN 60079-11:2007
Ta = -30C to See SD16R, SD32R, SD55R, SDRTD, SD32T3,
Schedule SD07R3, SD16R3, SD32R3, SD55R3
MTL
EN 60079-15:2005
MTL03ATEX0755X
Ex nA IIC T4
SD07, SD16, SD32, SD55, SD07X,
(EU)
EN 60079-14:2003
SD16X, SD32X, SD55X, SD07R, SD16R,
SD32R, SD55R, SD32T3, SD07R3,
SD16R3, SD32R3, SD55R3, SDRTD
Baseefa [IECEx]
IEC 60079-0: 2007-10
IECEx BAS 12.0003X
Ex ia IIC T4 Ga
SD07X, SD16X, SD32X, SD55X, SD07R,
(International)
IEC 60079-11: 2006
SD16R, SD32R, SD55R, SDRTD, SD32T3,
SD07R3, SD16R3, SD32R3, SD55R3
CSA/C/US
CSA C22.2 No. 0-M1991
LR 36637
EEx ia Class 1, SD07, SD16, SD32, SD55, SD07X,
(Canada, USA)
CSA C22.2 No. 157-M1992
Groups A, B SD55X, SD07R, SD16R, SD32R, SD55R,
UL 913, 5th edition
C and D, T4 SDRTD, SD32T3, SD07R3, SD16R3,
CSA C22.2 No. 142-M1987
Class 1, Div 2
SD32R3, SD55R3
CSA C22.2 No. 213-M1987
Groups A,B,C, D T4
UL
UL 497B Listed
E220693
Isolated loop SD07, SD16, SD32, SD55, SD07X,
(USA)
communication
SD16X, SD32X, SD55X, SD07R, SD16R,
circuits SD32R, SD55R, SD07R3, SD16R3,
SD32R3, SD55R3, SD32T3, SD55T3,
SD07X3, SD16X3, SD32X3, SD55X3,
SDRTD
AS/NZ3548:1995
__
Private Wire
SD07R
Austel
(Australia) AS/NZS4117:1996
TS001: 1997
0.28
+0.02
-0.0
+0.4mm
-0.0mm
7.0mm
4.03 (102.1mm)
0.28 rail (7mm)
4.32 (109.6mm)
0.6 rail (16mm)
3.99
(101.3mm)
Specifications SD Series
3.9
(99mm)
Ordering Data
SD07
SD16
SD32
SD55
7
5
250
4.2
500
7.7
<12
16
11
250
4.2
5
17
<25
32
22
250
4.2
5
36
<45
55
38
250
4.2
5
62
<90
30
25 kHz
Fuse disconnect
40
25 kHz
Fuse disconnect
60
25 kHz
Fuse disconnect
100
25 kHz
Fuse disconnect
SD07R
SD16R
SD32R
SD55R
7
5
400
2.7
500
7.7
<12
16
11
400
4.7
5
17
<25
32
22
400
10
5
36
<45
55
38
400
10
5
62
<90
30
50 MHz
High bandwidth
40
50 MHz
High bandwidth
60
50 MHz
High bandwidth
100
50 MHz
High bandwidth
Technical Data
Nominal voltage+(Un) Vdc
Nominal voltage+(Un) Vac
Nominal current (In) mA
Series resistance /line
Max. leakage current A
Rated voltage (MCOV) Uc
Voltage protection level (Up)
@1kV/s V
Residual voltage @ isn V
Bandwidth frequency fG
Special feature
Ordering Data
Technical Data
Nominal voltage+(Un) Vdc
Nominal voltage+(Un) Vac
Nominal current (In) mA
Series resistance /line
Max. leakage current A
Rated voltage (MCOV) Uc
Voltage protection level (Up)
@1kV/s V
Residual voltage @ isn V
Bandwidth frequency fG
Special feature
131
Ordering Data
SD07X
SD16X
D32X
SD55X
7
5
400
2.2
500
7.7
<12
16
11
400
2.2
5
17
<25
32
22
400
2.2
5
36
<45
55
38
400
2.2
5
62
<90
30
25 kHz
Low resistance
40
25 kHz
Low resistance
60
25 kHz
Low resistance
100
25 kHz
Low resistance
SD32T3
SD07R3
SD16R3
SD32R3
SD55R3
32
22
400
2.2
5
36
<45
7
5
400
2.7
500
7.7
<12
16
11
400
4.7
5
17
<25
32
22
400
10
5
36
<45
55
38
400
10
5
62
<90
75
720 kHz
3 terminal
30
50 MHz
3 terminal
40
50 MHz
3 terminal
60
50 MHz
3 terminal
100
50 MHz
3 terminal
SDRTD
SDPSTN
SD150X
SD275X
1
0.75
10
2.7
0.3
5
<12
162
114
550
4.7
5
175
<200
150
120
3A
0.1
50 ac rms; 170 ac
130 ac rms
<400
320
240
3A
0.1
50 ac rms; 360 ac
275 ac rms
<700
30
50 MHz
3-wire RTD
235
4 MHz
PSNT
450
-High current
850
-High current
Technical Data
Nominal voltage+(Un) Vdc
Nominal voltage+(Un) Vac
Nominal current (In) mA
Series resistance /line
Max. leakage current A
Rated voltage (MCOV) Uc
Voltage protection level (Up)
@1kV/s V
Residual voltage @ isn V
Bandwidth frequency fG
Special feature
Ordering Data
Technical Data
Nominal voltage+(Un) Vdc
Nominal voltage+(Un) Vac
Nominal current (In) mA
Series resistance /line
Max. leakage current A
Rated voltage (MCOV) Uc
Voltage protection level (Up)
@1kV/s V
Residual voltage @ isn V
Bandwidth frequency fG
Special feature
Ordering Data
Technical Data
Nominal voltage+(Un) Vdc
Nominal voltage+(Un) Vac
Nominal current (In) mA
Series resistance /line
Max. leakage current A
Rated voltage (MCOV) Uc
Voltage protection level (Up)
@1kV/s V
Residual voltage @ isn V
Bandwidth frequency fG
Special feature
Mounting Accessories
0494920000 Rail Holder
Grounding/Ground Rail Accessories
1010100000 Ground terminal, DIN-rail mounted
Accessories (Replacement)
SDF25 Replacement fuse pack 250mA standard
132
Dimensions
Approvals
Country (Authority)
Europe
(Baseefa)
Europe
(MTL)
USA (FM)
Canada (FM)
Standard
Certificate/File No.
Approved for
Product
EN 50014:1997 + A1 & A2
Baseefa04ATEX0303X
EEx ia IIC T4
SLP07D, SLP16D,
EN 50020:2002
SLP32D
EN 60079-26:2004
BS EN 50014:1998
MTL03ATEX0377X
EEx n IIC T4
SLP07D, SLP16D,
BS EN 50021:1999
SLP32D
EN 60079-15:2003
Class Nos. 3600 (1998),
3011208
IS/I/1/A-D
SLP07D, SLP16D,
3610 (2010), 3611 (1999),
I/0/AEx ia IIC
SLP32D
3615 (1989), 3810 incl.
I/0/AEx ia IIB
Supp 1 (1995-07 (1989-03),
NI/I/2/A-D
ANSI/NEMA 250 (1991)
NI/I/2/IIC
ANSI/ISA 60079-0 (2009
ANSI/ISA 60079-11 (2009)
ISA-S12.0.01 (1999)
C22.2 No. 213, 142, 94,
3025374C
IS/I/1/A-D
SLP07D, SLP16D,
157, 30
I/0/AEx ia IIC
SLP32D
ANSI/NEMA 250
I/0/AEx ia IIB
CAN/CSA-E79-0
NI/I/2/A-D
CAN/CSA-E79-11
NI/I/2/IIC
Ordering Data
SLP07D
SLP16D
SLP32D
7V
8V
1.50A
3kA
20kA
2.5kA
10V
<8V
50MHz
60pF
1.0
-40C to +80C
A2, B2, C1, C2, C3, D1
22kA
10kA
IP20
1Arms, 5T
80kPa - 160kPa
5% - 95% RH
16V
18V
1.50A
3kA
20kA
2.5kA
23V
<18V
50MHz
60pF
1.0
-40C to +80C
A2, B2, C1, C2, C3, D1
22kA
10kA
IP20
1Arms, 5T
80kPa - 160kPa
5% - 95% RH
24V
32V
1.50A
3kA
20kA
2.5kA
40V
<38V
50MHz
60pF
1.0
-40C to +80C
A2, B2, C1, C2, C3, D1
22kA
10kA
IP20
1Arms, 5T
80kPa - 160kPa
5% - 95% RH
Technical Data
Nominal voltage Un
Rated voltage (MCOV) Uc
Nominal current In
Nominal discharge current (8/20s) isn
Max discharge current (8/20s) Imax
Lightning impulse current (10/350s) Iimp
Residual voltage (@ isn) Up
Voltage protection level (@ 1kV/s) Up
Bandwidth fG
Capitance C
Series resistance R
Operating Temperature Range
Category tested
Overstressed fault mode in3kA
Impulse durability (8/20s)
Degree of protection
AC durability
Service conditions
Connections
Installation
133
Dimensions
MA15 Series
Industrial control systems utilizing programmable
logic controllers (plc) and industrial computers
are particularly vulnerable due to the aggressive
electrical environments for which they are intended,
such as process plants, factories and water
treatment sites.
Although industrial computers and PLCs are designed
to be rugged, the extra protection provided by the
DIN-rail mounting MA15 units is critical. Ideally
suited for protecting panel mounted equipment and
typically used in the controls section of a motor
control center (MCC), the MA15 range provides
surge and RFI protected power.
With a unique three-stage combination of protection
elements, these units suppress conducted RFI and
voltage surges. The circuit elements are: (1) surge
clipping components to absorb transient surges
that may otherwise damage equipment, (2) a
filter to suppress noise in the system and, (3) ring
suppression. Ring suppression prevents surges
causing the filter to ring (oscillate) under low load
conditions an effect that actually accentuates
interference in most commercially available filters.
Suitable for AC or DC application, MA15 units reduce
both electromagnetic emissions and the susceptibility
of the associated equipment to emissions from other
sources. MA15 devices also offer installation flexibility.
To protect circuits rated 15A or less, MA15 devices
should be installed in series. To protect higher current
circuits, simply install the MA15 in parallel.
LED status indication is standard with the MA15
units. Thermal fusing is also incorporated into each
18kA rated device as an additional safety feature.
MA15 modules also offer short circuit protection for
added safety.
MA15 devices are UL 1449 Recognized Components
(certified by UL for both US and Canadian
requirements) and exceed the requirements of IEC
61000-4-5. As MA15 units suppress conducted
RFI and voltage surges they enable associated
equipment to comply with this aspect of European
CE mark standards.
134
Ordering Data
Part No.
MA15D1SI
MA15D2SI
AC
120V, 47-63Hz
240V, 47-63Hz
Installation
DC
140V
280V
Approvals
Country (Authority)
United States
Canada
United States
Canada
Standard
UL 1449
Recognized Component
UL 1449
Recognized Component
UL 1604
Approved for
AC Power Product
Hazardous Locations
Class I, Division 2
Groups A, B, C and D
Product No.
MA15D1SI,
MA15D2SI
MA15D1SI,
MA15D2SI
Approvals
Specifications TP Series
All figures typical at 77F (25C) unless
otherwise stated
Maximum surge current
20kA peak current (8/20s waveform)
Leakage current
Less than 10A at maximum working voltage
Working voltage
35 VDC maximum
Bandwidth
1MHz
Resistance
No resistance introduced into loop
Ambient temperature limits
-40C to +80C (working)
-40F to +185F (working)
-40C to +85C (storage)
-40F to +185F (storage)
Humidity
5% to 95% RH (non-condensing)
Electrical connections
TP48
3 flying leads (line1, line 2 & ground)
TP48 3 Wire
4 flying leads (+ve, -ve, signal & ground)
TP48 4 Wire
5 flying leads (+ve, -ve, signal +ve, signal -ve, ground)
Wire size 32/0.2 (1.0mm2, 18 AWG)
Lead length 250mm (minimum)
Casing
ANSI 316 stainless steel hexagonal barstock, male thread
Threads
TP48-3-N & TP48-4-N
1/2 NPT
TP48-3-I & TP48-4-1
20mm ISO (M20 x 1.5)
TP48-3-G & TP48-4-G
G 1/2 (BSP 1/2)
Weight
175g (6.2oz)
Dimensions
See Figure 1
EMC compliance
To Generic Immunity Standards EN50082, part 2
for industrial environments
Electrical safety
EEx ia IIC T4, Ceq=O, Leq=0; the unit can be connected
without further certification into any intrinsically safe loop
with open circuit voltage <60V and input power <1.2W.
EEx d IIC T4; the unit is apparatus-approved to flame proof
(explosionproof) standards, and can be fitted into a similarly
approved housing.
Ordering Data
Nominal voltage Un
Rated voltage (MCOV) Uc
Nominal current In
Nominal discharge current (8/20s) isn
Max discharge current (8/20s) Imax
Lightning impulse current (10/350s) Iimp
Residual voltage @ isn Up
Voltage protection level @ 1kV/s Up
Bandwidth fG
Capacitance C
Series resistance R
Operating Temperature Range
Category tested
Overstressed fault mode in=3kA
Impulse durability (8/20s)
Degree of protection
AC durability
Service conditions
2.95
(75mm)
1.07
(27mm)
TP48-X-Y-Z
TP48-X-Y-NDI
TP48 Series
Technical Data
Figure 1
2.17
(55mm)
Intrinsically Safe:
I, II, II/1/A-G, I/O/IIC
Explosionproof: I/1/A-D
Nonincendive: I/2/A-D, I/2/IIC
Dust ignition proof: II, III/1/EFG
Special protection: II/2/FG
Ex ia IIC T4/T5/T6
Ex tD A20 IP6X T85C/T100C/
T135C
Dimensions
0.91
(23mm)
Approved for
Product
EEx ia IIC T6 (Tamb = -40 to 60C)
TP48-X-Y-Z
EEx ia IIC T5 (Tamb = -40 to 85C)
EEx ia IIC T4 (Tamb = -40 to 60C)
EEx d IIC T6 (Tamb = -40 to 60C)
TP48-X-Y-Z
EEx d IIC T5 (Tamb = -40 to 80C)
EEx d IIC T4 (Tamb = -40 to 85C)
Ex n II T6 (-40C<Tamb<+60C)
TP48-X-Y-Z
EEx n II T5 (-40C<Tamb<+85C)
Intrinsically Safe:
TP48-X-Y-Z
I, II, III/1/A-G, I/0/IIC
Explosionproof: I/1/A-D
Non incendive: I/2/A-D, I/2/IIC
Dust ignition proof: II,III/1/EFG
Special protection: II/2/FG
Lead length
9.85 (250mm)
minimum
Figure 2
35V
58V
--3kA
20kA
2.5kA
95V
L-G 500V
<76V
1MHz
100pF
---40C to +85C
A2, B2, C1, C2, C3, D1
12kA
10kA
IP66
1Arms, 5T
80kPa - 160kPa
5% - 95% RH
Ordering Data
Non-certified SPD - 1/2 NPT thread
Non-certified SPD - 20mm ISO thread
Non-certified SPD - G 1/2 (BSP 1/2 inch)
Non-certified SPD - 1/2 NPT thread
Non-certified SPD - 20mm ISO thread
Non-certified SPD - G 1/2 BSP 1/2 inch
Non-certified SPD - 1/2 NPT thread
Non-certified SPD - 20mm ISO thread
Non-certified SPD - G 1/2 BSP 1/2 inch
Certified SPD - 1/2 NPT thread
Certified SPD - 20mm ISO thread
Certified SPD - G 1/2 (BSP 1/2 inch)
Certified SPD - 1/2 NPT thread
Certified SPD - 20mm ISO thread
Certified SPD - G 1/2 - BSP 1/2 inch
Certified SPD - 1/2 NPT thread
Certified SPD - 20mm ISO thread
Certified SPD - G 1/2 - BSP 1/2 inch
Part No.
TP48N
TP48I
TP48G
TP483N
TP483I
TP483G
TP484N
TP484I
TP484G
TP48NNDI
TP48INDI
TP48GNDI
TP483NNDI
TP483INDI
TP483GNDI
TP484NNDI
TP484INDI
TP484GNDI
Installation
The TP units are designed for mounting directly into
an unused conduit entry on a process transmitter
housing. Generally, two such entries are provided,
one of which is used for the loop wiring. On the
unused entry, the blanking plug or other closure
device is removed and an appropriately threaded TP
screwed into its place. The transmitter specication
should provide information indicating the required
thread type. TP units can be installed using thread
adaptors if necessary, including certied adaptors in
hazardous area applications.
For applications where two conduit entries are
not provided or where both are used for electrical
connections, TP units can be housed in conventional
conduit hub or junction boxes, provided access
to the loop terminals is possible. Figure 2 shows
connection details for 3 & 4 wire process transmitter.
135
Industrial Ethernet
Industrial Ethernet
Active Components
Ethernet technology is an established standard in office
communication and has existed for many years. Without it,
effective communications between the different participants
like PCs, printers, data servers etc. would no longer be
possible.
In recent years this technology has been expanded under
the term Industrial Ethernet and implemented in automation
systems. The common goal of both manufacturer and user is
to make networking automation system components easier
and more effective. To make process data and diagnostic
functions device-independent when exchanged between
network participants, all equipment in a plant should be
linked with just one bus technology.
Industrial applications, however, differ significantly from
office applications. There are normally much higher
demands placed on the communication devices in the
industrial setting. These include, for example:
Installation conditions
Environmental conditions
Protocols
Approvals
Weidmullers Industrial Ethernet components meet all of
these requirements as they have the properties listed below:
Reliable (redundant) power supply for uninterrupted
network operation
Resistance to extreme temperatures
Immune to electromagnetically caused malfunctions
Insensitive to vibration, shock and corrosive environments
Conformity with various certification standards
Longevity
These rugged devices can therefore be used world-wide in
different industries and applications.
PWR2
Back-up
power supply
PWR1
DC - wide input voltage range of
9.6 to 60 V DC (Basic Line)
input voltage range of 18 -30 V AC (Basic Line)
136
12-48 V DC
power supply
Industrial Ethernet
+75 C
to
40 C
137
Industrial Ethernet
Switches
138
Basic Line
Value Line
Basic Line
Value Line
Premium Line
Weidmullers Premium Line series
completes the switch range for the
high-end sector and is particularly
suitable for complex network solutions
with high traffic levels. The devices
are available in different versions, ie.
number of ports, transmission rate (Fast
and Gigabit Ethernet) and the type of
connection (copper and fibre-optic).
With their advanced ring redundancy
technology (recovery time 20 ms),
these devices increase the reliability
and availability of your industrial
network. The option to use SFP
transceivers offer a high degree of
flexibility and the Gigabit variants also
allow their use in networks with high
traffic loads.
Premium Line
139
Ports total
Ports copper
6
4
8
8
Ports fibre
140
Type
1240840000
IE-SW-BL05-5TX
1240850000
IE-SW-BL05T-5TX
1240870000
IE-SW-BL05-4TX-1SCS
1286530000
IE-SW-BL05T-4TX-1SCS
1240880000
IE-SW-BL05-4TX-1ST
1286540000
IE-SW-BL05T-4TX-1ST
1240890000
IE-SW-BL05-4TX-1SC
1286550000
IE-SW-BL05T-4TX-1SC
1240900000
IE-SW-BL08-8TX
1286560000
IE-SW-BL08T-8TX
1240910000
IE-SW-BL08-6TX-2SC
1240920000
IE-SW-BL08T-6TX-2SC
1240930000
IE-SW-BL08-6TX-2ST
1286570000
IE-SW-BL08T-6TX-2ST
1412070000
IE-SW-BL08-7TX-1SC
1412080000
IE-SW-BL08T-7TX-1SC
1412090000
IE-SW-BL08-7TX-1ST
1412100000
IE-SW-BL08T-7TX-1ST
1240950000
IE-SW-BL08-7TX-1SCS
1286580000
IE-SW-BL08T-7TX-1SCS
1412110000
IE-SW-BL08-6TX-2SCS
1412120000
IE-SW-BL08T-6TX-2SCS
1241250000
IE-SW-BL05-5GT
5 GE
1286850000
IE-SW-BL05T-5GT
5 GE
1241270000
IE-SW-VL08-8GT
8 GE
1286860000
IE-SW-VL08T-8GT
8 GE
1241280000
IE-SW-VL08-6GT-2GS
1286870000
IE-SW-VL08T-6GT-2GS
1240980000
IE-SW-VL09T-6TX-3SC
1241000000
IE-SW-VL16-16TX
1286590000
IE-SW-VL16T-16TX
1241030000
IE-SW-VL16-14TX-2SC
1286610000
IE-SW-VL16T-14TX-2SC
1241050000
IE-SW-VL16-14TX-2ST
1286620000
IE-SW-VL16T-14TX-2ST
1240940000
IE-SW-VL08MT-8TX
1240970000
IE-SW-VL08MT-5TX-3SC
1345240000
IE-SW-VL08MT-5TX-1SC-2SCS
1344770000
IE-SW-VL08MT-6TX-2SC
1240990000
IE-SW-VL08MT-6TX-2ST
1241020000
IE-SW-VL08MT-6TX-2SCS
1241040000
IE-SW-PL08M-8TX
1286780000
IE-SW-PL08MT-8TX
FE
GE
GEC
Ports SFP
Part No.
= Fast Ethernet
= Gigabit-Ethernet
= Gigabit-Ethernet Kombi-Ports
6 GE
2 GEC
6 GE
2 GEC
10
16
8
16
18
14
16
2
5
14
2
Managed
10
4
Unmanaged
9
6
Temperature
Fibre-optic interface
10 +60 C
145
40 +75 C
145
10 +60 C
SC-Singlemode
145
40 +75 C
SC-Singlemode
145
10 +60 C
ST-Multimode
145
40 +75 C
ST-Multimode
145
10 +60 C
SC-Multimode
145
40 +75 C
SC-Multimode
145
10 +60 C
145
40 +75 C
145
10 +60 C
SC-Multimode
145
40 +75 C
SC-Multimode
145
10 +60 C
ST-Multimode
145
40 +75 C
ST-Multimode
145
10 +60 C
SC-Multimode
145
40 +75 C
SC-Multimode
145
10 +60 C
ST-Multimode
145
40 +75 C
ST-Multimode
145
10 +60 C
SC-Singlemode
145
40 +75 C
SC-Singlemode
145
10 +60 C
SC-Singlemode
145
40 +75 C
SC-Singlemode
0 +60 C
145
147
40 +75 C
147
0 +60 C
147
40 +75 C
147
0 +60 C
SFP-Slot
147
40 +75 C
SFP-Slot
147
40 +75 C
SC-Multimode
0 +60 C
146
146
40 +75 C
Page
146
0 +60 C
SC-Multimode
40 +75 C
SC-Multimode
146
0 +60 C
ST-Multimode
146
40 +75 C
ST-Multimode
40 +75 C
40 +75 C
146
146
153
SC-Multimode
153
40 +75 C SC-Multimode/SC-Singelmode
153
40 +75 C
SC-Multimode
153
40 +75 C
ST-Multimode
153
40 +75 C
SC-Singlemode
153
0 +60 C
154
40 +75 C
154
141
Ports total
Ports copper
Ports fibre
6
4
1
8
8
Type
IE-SW-PL08M-6TX-2SC
1286790000
IE-SW-PL08MT-6TX-2SC
1241080000
IE-SW-PL08M-6TX-2ST
1286800000
IE-SW-PL08MT-6TX-2ST
1241090000
IE-SW-PL08M-6TX-2SCS
1286810000
IE-SW-PL08MT-6TX-2SCS
1241100000
IE-SW-PL16M-16TX
1286820000
IE-SW-PL16MT-16TX
1241120000
IE-SW-PL16M-14TX-2SC
1286830000
IE-SW-PL16MT-14TX-2SC
1241130000
IE-SW-PL16M-14TX-2ST
1286840000
IE-SW-PL16MT-14TX-2ST
1241290000
IE-SW-PL10M-3GT-7TX
1286930000
IE-SW-PL10MT-3GT-7TX
1241300000
IE-SW-PL10M-1GT-2GS-7TX
1286940000
IE-SW-PL10MT-1GT-2GS-7TX
1241320000
IE-SW-PL18M-2GC-16TX
1286970000
IE-SW-PL18MT-2GC-16TX
1241330000
IE-SW-PL18M-2GC-14TX2SC
1286990000
IE-SW-PL18MT-2GC14TX2SC
1241340000
IE-SW-PL18M-2GC14TX2ST
1287000000
IE-SW-PL18MT-2GC14TX2ST
1241350000
IE-SW-PL18M-2GC14TX2SCS
1287010000
IE-SW-PL18MT-2GC14TX2SCS
1241370000
IE-SW-PL09M-5GC-4GT
1287020000
IE-SW-PL09MT-5GC-4GT
FE
GE
GEC
142
= Fast Ethernet
= Gigabit-Ethernet
= Gigabit-Ethernet Kombi-Ports
7
1
Ports SFP
Part No.
10
16
8
16
2
5
18
14
2
14
2
3 GE
16
7 FE
3 GE
7 FE
1GE
2 GEC
7 FE
1GE
2 GEC
7 FE
2 GEC
16 FE
2 GEC
16 FE
2 GEC
14 FE
2 GEC
14 FE
2 GEC
14 FE
2 GEC
14 FE
2 GEC
14 FE
2 GEC
5 GEC
4 GE
5 GEC
4 GE
Managed
10
4
Unmanaged
9
6
14 FE
Temperature
Fibre-optic interface
Page
154
0 +60 C
SC-Multimode
40 +75 C
SC-Multimode
154
0 +60 C
ST-Multimode
154
40 +75 C
ST-Multimode
154
0 +60 C
SC-Singlemode
154
40 +75 C
SC-Singlemode
0 +60 C
154
154
40 +75 C
154
0 +60 C
SC-Multimode
154
40 +75 C
SC-Multimode
154
0 +60 C
ST-Multimode
154
40 +75 C
ST-Multimode
154
0 +60 C
155
40 +75 C
155
0 +60 C
SFP-Slot
155
40 +75 C
SFP-Slot
155
0 +60 C
SFP-Slot
156
40 +75 C
SFP-Slot
156
0 +60 C
SC-Multimode / SFP-Slot
156
40 +75 C
SC-Multimode / SFP-Slot
156
0 +60 C
ST-Multimode / SFP-Slot
156
40 +75 C
ST-Multimode / SFP-Slot
156
0 +60 C
SC-Singlemode / SFP-Slot
156
40 +75 C
SC-Singlemode / SFP-Slot
156
0 +60 C
SFP-Slot
157
40 +75 C
SFP-Slot
157
143
Unmanaged Switches
Switches are the basic coupling elements in Ethernet
networks. They connect the Ethernet participants together.
In an Ethernet network the communication basically
originates from the participants. The switches connect
the participants together and enable the communication.
Unmanaged switches are the simplest active network
component. They do not need to be configured and are
therefore very flexible. They use the basic standard protocols,
such as auto-negotiation, auto-crossing, and flow-control and
can automatically adjust to the different transmission speeds
or connector wiring.
Unmanaged switches are protocol transparent. Each port on
the switch creates an individual collision domain. The use
of twisted-pair cabling with an RJ45 interface or fibre-optic
cable based on the IEEE 802.3 specification interfaces are
supported by all Weidmuller switches.
144
IE-SW-BL05-Series
T;u\%
IE-SW-BL08-Series
Technical Data
Technology
Standards
Processing Type
Flow Control
Switch Properties
MAC Table Size
Packet Buffer Size
Interface
Fiber Ports
RJ45 Ports
DIP Switches
LED Indicators
Optical Fiber
Wavelength
Max. Transmit power
Min. Transmit power
RX Sensitivity
Link Budget
Typical Distance
Saturation
Power Requirements
Input Voltage
Input Current
Weight
Installation
Environmental Limits
Operating Temperature
Storage Temperature
singlemode
1310 nm
0 dBm
-5 dBm
-34 dBm
29 dB
40 km (9/125 m
singlemode cable)
-3 dBm
Environmental Limits
Ambient Relative Humidity
Regulatory Approvals
Safety
Hazardous Location
EMI
EMC
5 to 95 % (non-condensing)
UL 508
UL/cUL Class I, Division 2, Groups A, B, C and D; ATEX Zone 2, Ex nC IIC
FCC Part 15, CISPR (EN55022) class A
EN61000-4-2 (ESD), level 3;
EN61000-4-3 (RS), level 3;
EN61000-4-4 (EFT), level 3;
EN61000-4-5 (Surge), level 3;
EN61000-4-6 (CS), level 3;
EN61000-4-8; EN61000-4-11
Maritime
DNV, GL (not for 1412110000, 1412120000, 1412070000,
1412080000, 1412090000, 1412100000)
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-32
Vibration
IEC 60068-2-6
MTBF (meantime between failures)
Time
425,000 hrs
Database
Telcordia (Bellcore), GB
Warranty
Warranty Period
5 years
Ordering Data
Port Variants
Model Type
5 * RJ45
IE-SW-BL05-5TX
IE-SW-BL05T-5TX
IE-SW-BL05-4TX-1SC
IE-SW-BL05T-4TX-1SC
IE-SW-BL05-4TX-1ST
IE-SW-BL05T-4TX-1ST
IE-SW-BL05-4TX-1SCS
IE-SW-BL05T-4TX-1SCS
IE-SW-BL08-8TX
IE-SW-BL08T-8TX
IE-SW-BL08-6TX-2SC
IE-SW-BL08T-6TX-2SC
IE-SW-BL08-6TX-2ST
IE-SW-BL08T-6TX-2ST
IE-SW-BL08-6TX-2SCS
IE-SW-BL08T-6TX-2SCS
IE-SW-BL08-7TX-1SC
IE-SW-BL08T-7TX-1SC
IE-SW-BL08-7TX-1ST
IE-SW-BL08T-7TX-1ST
IE-SW-BL08-7TX-1SCS
IE-SW-BL08T-7TX-1SCS
4 * RJ45, 1 * SC-Multimode
4 * RJ45, 1 * ST-Multimode
4 * RJ45, 1 * SC-Singlemode
8 * RJ45
6 * RJ45, 2 * SC-Multimode
6 * RJ45, 2 * ST-Multimode
6 * RJ45, 2 * SC-Singlemode
7 * RJ45, 1 * SC-Multimode
7 * RJ45, 1 * ST-Multimode
7 * RJ45, 1 * SC-Singlemode
Operating
Temperature
-10 to +60 C
-40 to +75 C
-10 to +60 C
-40 to +75 C
-10 to +60 C
-40 to +75 C
-10 to +60 C
-40 to +75 C
-10 to +60 C
-40 to +75 C
-10 to +60 C
-40 to +75 C
-10 to +60 C
-40 to +75 C
-10 to +60 C
-40 to +75 C
-10 to +60 C
-40 to +75 C
-10 to +60 C
-40 to +75 C
-10 to +60 C
-40 to +75 C
Part No.
1240840000
1240850000
1240890000
1286550000
1240880000
1286540000
1240870000
1286530000
1240900000
1286560000
1240910000
1240920000
1240930000
1286570000
1412110000
1412120000
1412070000
1412080000
1412090000
1412100000
1240950000
1286580000
Accessories
19'' Rack Mounting Kit
Cable fixing kit
Model Type
RM-KIT
IE-CFK-05
Part No.
1241440000
1339610000
145
IE-SW-VL16-Series
TX
PWR1
PWR2
FAULT
RX
100M
100M 100M
TX
9
RX
100M
T;u\%
2
10M
Technical Data
Technology
Standards
Processing Type
Flow Control
Switch Properties
MAC Table Size
Packet Buffer Size
Interface
Fiber Ports
RJ45 Ports
DIP Switches
LED Indicators
Alarm Contact
Optical Fiber
Wavelength
Max. TX
Min. TX
RX Sensitivity
Link Budget
Typical Distance
Saturation
Power Requirements
Input Voltage
Input Current
Weight
146
Physical Characteristics
Installation
Environmental Limits
Operating Temperature
Storage Temperature
Ambient Relative Humidity
Regulatory Approvals
Safety
Hazardous Location
EMI
EMC
DIN-Rail mounting
Standard Models: 0 to 60 C (32 to 140 F)
Wide Temp. Models: -40 to 75 C
(-40 to 167 F)
-40 to 85 C (-40 to 185 F)
5 to 95 % (non-condensing)
IE-SW-VL09...Series: UL 508, UL 60950-1,
CSA C22.2 No. 60950-1, EN60950-1
IE-SW-VL16...Series: UL 508, UL 60950-1, EN60950-1
UL/cUL Class I, Division 2, Groups A, B, C
and D; ATEX Zone 2, Ex nC IIC
FCC Part 15, CISPR (EN55022) class A
EN61000-4-2 (ESD), level 3;
EN61000-4-3 (RS), level 3;
EN61000-4-4 (EFT), level 3;
EN61000-4-5 (Surge), level 3;
EN61000-4-6 (CS), level 3;
DNV, GL
IEC 60068-2-27
IEC 60068-2-32
IEC 60068-2-6
Maritime
Shock
Freefall
Vibration
MTBF (mean time between failures)
Time
IE-SW-VL09...Series: 396,000 hrs
IE-SW-VL16...Series: 257,000 hrs
Database
MIL-HDBK-217F, GB 25 C
Warranty
Warranty Period
5 years
Ordering Data
Port Variants
Model Type
16 * RJ45
IE-SW-VL16-16TX
IE-SW-VL16T-16TX
IE-SW-VL09T-6TX-3SC
IE-SW-VL16-14TX-2SC
IE-SW-VL16T-14TX-2SC
IE-SW-VL16-14TX-2ST
IE-SW-VL16T-14TX-2ST
6 * RJ45, 3 * SC-Multimode
14 * RJ45, 2 * SC-Multimode
14 * RJ45, 2 * ST-Multimode
Operating
Temperature
0 to +60 C
-40 to +75 C
-40 to +75 C
0 to +60 C
-40 to +75 C
0 to +60 C
-40 to +75 C
Part No.
1241000000
1286590000
1240980000
1241030000
1286610000
1241050000
1286620000
Accessories
19'' Rack Mounting Kit
Model Type
RM-KIT
Part No.
1241440000
IE-SW-BL05GT-Series
Technical Data
Technology
Standards
Processing Type
Flow Control
Switch Properties
MAC Table Size
Packet Buffer Size
Jumbo frame support
Interface
Fiber Ports
RJ45 Ports
DIP Switches
LED Indicators
Alarm Contact
Power Requirements
Input Voltage
Input Current
Connection
Reverse Polarity Protection
Physical Characteristics
Housing
Dimensions (W x H x D)
Weight
Installation
Environmental Limits
Operating Temperature
Storage Temperature
Ambient Relative Humidity
Regulatory Approvals
Safety
Hazardous Location
EMI
T;u\%
Regulatory Approvals
EMC
Maritime
Shock
Freefall
Vibration
MTBF (mean time between failures)
Time
478.000 hrs (Serie IE-SW-BL05-5GT)
325.000 hrs (Serie IE-SW-VL08-XGT)
Database
Telcordia (Bellcore), GB (IE-SW-VL08-xGT series)
Warranty
Warranty Period
5 years
Ordering Data
Port Variants
Model Type
5 * RJ45 10/100/1000BaseT(X)
IE-SW-BL05-5GT
IE-SW-BL05T-5GT
IE-SW-VL08-8GT
IE-SW-VL08T-8GT
IE-SW-VL08-6GT-2GS
IE-SW-VL08T-6GT-2GS
8 * RJ45 10/100/1000BaseT(X)
6 * RJ45 10/100/1000BaseT(X),
2 Combo Ports (10/100/1000
BaseT(X) or 100/1000BaseSFP)
Accessories
19'' Rack Mounting Kit
Model Type
RM-KIT
Operating
Temperature
0 to 60 C
-40 to +75 C
0 to +60 C
-40 to +75 C
0 to +60 C
-40 to +75 C
Part No.
1241250000
1286850000
1241270000
1286860000
1241280000
1286870000
Part No.
1241440000
Metal, IP 30 protection
IE-SW-BL05-5GT:
35 x 130 x 105 mm (1.37 x 5.12 x 4.13 in)
IE-SW-VL08-xGT:
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
IE-SW-BL05-5GT: 290 g
IE-SW-VL08-8GT 630 g
DIN-Rail mounting
Standard Models: 0 to 60 C (32 to 140 F)
Wide Temp. Models: -40 to 75 C
(-40 to 167 F) (on request)
-40 to 85 C (-40 to 185 F)
5 to 95 % (non-condensing)
UL 508
UL/cUL Class I, Division 2, Groups A, B, C, and D;
ATEX Zone 2, Ex nC IIC
FCC Part 15, CISPR (EN55022) class A
147
Managed Switches
148
Ring redundancy
The Turbo-Ring technology integrated into Weidmullers
switches allows you to restore a network connection in case
of failure in under 20 ms, and this with up to 250 switches
in a ring. Turbo-Ring offers thee different topology options
(Ring-Coupling, Dual-Ring and Dual-Homing) for different
application requirements to ensure the maximum possible
availability of industrial network applications.
Turbo Ring
(recovery time < 20 ms)
Ring-Coupling
In some applications, it is not sensible to have all equipment
and devices in a single large redundant ring networked
together, as some of the devices may be located in remote
parts of the plant. For such structures, Ring-Coupling is
ideal. It connects devices in multiple, smaller rings that are
connected redundantly and directly with one another.
Primary Path
Master
Master
Backup Path
Dual-Homing
With Dual-Homing, two separate rings are connected
through one managed switch via two independent
connection points. The back-up connection is activated if the
primary connection fails.
Primary Path
Master
Backup Path
Master
149
Dual-Ring
In a Dual-Ring, two neighbouring rings are connected
with one another using one switch, without the need for
additional ports or cabling. This configuration reduces
the total number of ports and saves cabling costs, as an
additional primary and back-up line is not needed.
Master
Master
Turbo-Chain
Managed Ethernet Switch
Backup Path
SPS
SPS
SPS
SPS
150
SPS
1
8
SPS
SPS
SPS
Low priority
Data
Highest priority
Control messages
Low
priority
High
priority
Highest
priority
High priority
Management
messages
Group 1
Multicast messages
IGMP group 2
Group 2
Multicast messages
IGMP group 1
IGMP group 2
IGMP group 1
M
M
M
M
S
S
SPS
SPS
S
SPS
Boundary clock:
is a slave to the grand master
clock, and has master status
over its own slaves
Ordinary clock:
is a slave to its
master
151
VLAN 1
VLAN 2
3. Tier
SPS
1. Tier
Division 2
Client
www
Server
152
2. Tier
SPS
SPS
Division 1
VLAN 3
Division 3
Technical Data
T;u\%
Standards
IEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT(X) and 100BaseFXIEEE 802.3x for Flow Control
IEEE 802.1D for Spanning Tree ProtocolIEEE 802.1w for Rapid STPIEEE 802.1p for Class of Service
IEEE 802.1Q for VLAN Tagging
Protocols
IGMPv1/v2GMRPGVRPSNMPv1/v2c/v3DHCP Server/ClientTFTPSNTPSMTPRARPR
MONHTTPTelnetSyslogDHCP Option 66/67/82BootPLLDPModbus/TCPIPv6
MIB
MIB-IIEthernet-like MIBP-BRIDGE MIBBridge MIBRSTP MIBRMON MIB Group 1, 2, 3, 9
Flow Control
IEEE 802.3x flow control back pressure flow control
Switch Properties
MAC Table Size
8K
Packet Buffer Size
1 MBit
Interface
Fiber Ports
100BaseFX ports (SC/ST connector)
RJ45 Ports
10/100BaseT(X) auto negotiation speed,
Full/Half duplex mode, and
auto MDI/MDI-X connection
Console Port
RS 232 (RJ45 connector)
DIP Switches
Turbo Ring, Master, Coupler, Reserve
LED Indicators
PWR1, PWR2, FAULT, MSTR/HEAD, CPLR/TAIL, 10/100M
Alarm Contact
1 relay output with current carrying capacity of 1 A @ 24 V DC
Optical Fiber
100BaseFX
multimode
singlemode
Wavelength
1300 nm
1310 nm
Max. TX
-10 dBm
0 dBm
Min. TX
-20 dBm
-5 dBm
RX Sensitivity
-32 dBm
-34 dBm
Link Budget
12 dB
29 dB
5 km a
40
km c
Typical Distance
4 km b
Saturation
-6 dBm
-3 dBm
a
50/125 m, 800 MHz*km fiber optic cable
b
62.5/125 m, 500 MHz*km fiber optic cable
c
9/125 m singlemode fiber optic cable
Power Requirements
Input Voltage
24 V DC (12 to 45 V DC), redundant dual inputs
Input Current
IE-SW-VL08M-8TX: 0.26 A @ 24 V
IE-SW-VL08M-6TX-2ST/SC: 0.35 A @ 24 V
IE-SW-VL08M-5TX-3SC: 0.32 A @ 24 V
Overload Current Protection
Present
Connection
1 removable 6-contact terminal block
Reverse Polarity Protection
Present
Physical Characteristics
Housing
Dimensions (W x H x D)
Weight
Installation
Environmental Limits
Operating Temperature
Storage Temperature
Ambient Relative Humidity
Regulatory Approvals
Safety
Hazardous Location
EMI
EMC
Metal, IP 30 protection
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
IE-SW-VL08MT-...8TX/6TX-2SC/6TX-2ST/6TX-2SCS: 650 g
IE-SW-VL08MT-...5TX/3SC/5TX-1SC-2SCS: 890 g
DIN-Rail mounting
-40 to 75 C (-40 to 167 F)
-40 to 85 C (-40 to 185 F)
5 to 95 % (non-condensing)
UL 508, UL 60950-1, CSA C22.2 No. 60950-1, EN60950-1
UL/cUL Class I, Division 2, Groups A, B, C and D;
ATEX-Zone 2, Ex nC IIC (not for 1345240000)
FCC Part 15, CISPR (EN55022) class A
EN61000-4-2 (ESD), level 3;
EN61000-4-3 (RS), level 3;
EN61000-4-4 (EFT), level 3;
EN61000-4-5 (Surge), level 3;
EN61000-4-6 (CS), level 3;
EN61000-4-8
DNV, GL (not for 1345240000 and 1241020000)
IEC 60068-2-27
IEC 60068-2-32
IEC 60068-2-6
Maritime
Shock
Freefall
Vibration
MTBF (mean time between failures)
Time
363,000 hrs
Database
Telcordia (Bellcore), GB
Warranty
Warranty Period
5 years
Ordering Data
Port Variants
8 * RJ45
5 * RJ45, 3 * SC-Multimode
5 * RJ45, 1 * SC-Multimode,
2 * SC-Singlemode
6 * RJ45, 2 * ST-Multimode
6 * RJ45, 2 * SC-Multimode
6 * RJ45, 2 * SC-Singlemode
Accessories
External Backup and
Restore Module
19'' Rack Mounting Kit
Model Type
Operating
Temperature
IE-SW-VL08MT-8TX
-40 to +75 C
IE-SW-VL08MT-5TX-3SC
-40 to +75 C
IE-SW-VL08MT-5TX-1SC-2SCS -40 to +75 C
1240940000
1240970000
1345240000
IE-SW-VL08MT-6TX-2ST
IE-SW-VL08MT-6TX-2SC
IE-SW-VL08MT-6TX-2SCS
1240990000
1344770000
1241020000
-40 to +75 C
-40 to +75 C
-40 to +75 C
Part No.
Model Type
EBR-Module RS232
Part No.
1241430000
RM-KIT
1241440000
153
IE-SW-PL16M-Series
135.0 mm (5.3 in)
T;u\%
Technical Data
Standards
IEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT (X) and 100BaseFXIEEE 802.3x for Flow
ControlIEEE 802.1D for Spanning Tree ProtocolIEEE 802.1w for Rapid STPIEEE 802.1Q for VLAN
TaggingIEEE 802.1p for Class of ServiceIEEE 802.1X for AuthenticationIEEE 802.3ad for Port Trunk
with LACP
Protocols
IGMPv1/v2GVRPSNMPv1/v2c/v3DHCP Server/ClientBootPTFTPSNTPSMTPRARP
GMRPLACPRMONHTTPHTTPSTelnetSyslogDHCP Option 66/67/82SSHSNMP
InformModbus/TCPLLDPIEEE 1588 PTPIPv6
MIB
MIB-IIEthernet-Like MIBP-BRIDGE MIBQ-BRIDGE MIBBridge MIBRSTP MIB
RMON MIB Group 1, 2, 3, 9
Flow Control
IEEE 802.3x flow controlback pressure flow control
Switch Properties
Priority Queues
4
Max. Number of Available VLANs
64
VLAN ID Range
VID 1 to 4094
IGMP Groups
256
MAC Table Size
8K
Packet Buffer Size
1 MBit (IE-SW-PL08M), 2 MBit (IE-SW-PL16M)
Interface
Fiber Ports
100BaseFX ports (SC/ST connector)
RJ45 Ports
10/100BaseT(X) auto negotiation speed,
Full/Half duplex mode, and auto MDI/MDI-X connection
Console Port
RS 232 (RJ45 connector)
DIP Switches
Turbo-ring, master, coupler, reserve (only IE-SW-PL08M)
LED Indicators
PWR1, PWR2, FAULT, MSTR/HEAD,
CPLR/TAIL, 10/100M
Alarm Contact
2 relay outputs with current carrying
capacity of 1 A @ 24 V DC
Digital Inputs
2 inputs with the same ground,
electrically isolated
+13 to +30 V for state 1
-30 to +3 V for state 0
Max. input current: 8 mA
Optical Fiber
Wavelength
Max. TX
Min. TX
RX Sensitivity
Link Budget
Typical Distance
Saturation
Power Requirements
Input Voltage
Input Current
154
multimode
1300 nm
-10 dBm
-20 dBm
-32 dBm
12 dB
5 km (50/125 m
multimode cable)
4 km (62.5/125 m
multimode cable)
-6 dBm
singlemode
1310 nm
0 dBm
-5 dBm
-34 dBm
29 dB
40 km (9/125 m
singlemode cable)
-3 dBm
Power Requirements
Overload Current Protection
Connection
Reverse Polarity Protection
Physical Characteristics
Housing
Dimensions (W x H x D)
Weight
Installation
Environmental Limits
Operating Temperature
Storage Temperature
Ambient Relative Humidity
Regulatory Approvals
Safety
Hazardous Location
EMI
EMC
Present
2 removable 6-contact terminal blocks
Present
Metal, IP 30 protection
IE-SW-PL08M: 80.2 x 135 x 105 mm (3.16 x 5.31 x 4.13 in)
IE-SW-PL16M: 94 x 135 x 142.7 mm (3.7 x 5.31 x 5.62 in)
IE-SW-PL08M: 1040 g, IE-SW-PL16M: 1586 g
DIN-Rail mounting
Standard Models: 0 to 60 C (32 to 140 F)
Wide Temp. Models: -40 to 75 C
(-40 to 167 F) (on request)
-40 to 85 C (-40 to 185 F)
5 to 95 % (non-condensing)
UL 508, UL 60950-1, CSA C22.2 No. 60950-1, EN60950-1
UL/cUL Class I, Division 2, Groups A, B, C and D;
ATEX-Zone 2, Ex nC IIC
FCC Part 15, CISPR (EN55022) class A
EN61000-4-2 (ESD): IE-SW-PL08M...Series: level 3
IE-SW-PL16M...Series: level 2;
EN61000-4-3 (RS) level 3; EN61000-4-4 (EFT) level 3;
EN61000-4-5 (Surge) level 3;
EN61000-4-6 (CS) level 3; EN61000-4-8
DNV, GL
IEC 60068-2-27
IEC 60068-2-32
IEC 60068-2-6
Maritime
Shock
Freefall
Vibration
MTBF (mean time between failures)
Time
IE-SW-PL08M...Series: 339,000 hrs
IE-SW-PL16M...Series: 247,000 hrs
Database
Telcordia (Bellcore), GB
Warranty
Warranty Period
5 years
Ordering Data
Port Variants
Model Type
8 * RJ45
IE-SW-PL08M-8TX
IE-SW-PL08MT-8TX
IE-SW-PL08M-6TX-2SC
IE-SW-PL08MT-6TX-2SC
IE-SW-PL08M-6TX-2ST
IE-SW-PL08MT-6TX-2ST
IE-SW-PL08M-6TX-2SCS
IE-SW-PL08MT-6TX-2SCS
IE-SW-PL16M-16TX
IE-SW-PL16MT-16TX
IE-SW-PL16M-14TX-2SC
IE-SW-PL16MT-14TX-2SC
IE-SW-PL16M-14TX-2ST
IE-SW-PL16MT-14TX-2ST
6 * RJ45, 2 * SC-Multimode
6 * RJ45, 2 * ST-Multimode
6 * RJ45, 2 * SC-Singlemode
16 * RJ45
14 * RJ45, 2 * SC-Multimode
14 * RJ45, 2 * ST-Multimode
Operating
Temperature
0 to 60 C
-40 to +75 C
0 to 60 C
-40 to +75 C
0 to 60 C
-40 to +75 C
0 to 60 C
-40 to +75 C
0 to 60 C
-40 to +75 C
0 to 60 C
-40 to +75 C
0 to 60 C
-40 to +75 C
Part No.
1241040000
1286780000
1241070000
1286790000
1241080000
1286800000
1241090000
1286810000
1241100000
1286820000
1241120000
1286830000
1241130000
1286840000
IE-SW-PL10M-Series
T;u\%
105.0 mm (4.13 in)
Technical Data
Standards
IEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT (X) and 100BaseFXIEEE 802.3ab for
1000BaseT(X)IEEE 802.3z for 1000BaseXIEEE 802.3x for Flow ControlIEEE 802.1D for Spanning
Tree ProtocolIEEE 802.1w for Rapid STPIEEE 802.1Q for VLAN TaggingIEEE 802.1p for Class of
ServiceIEEE 802.1X for AuthenticationIEEE 802.3ad for Port Trunk with LACP
Protocols
IGMPv1/v2GMRPGVRPSNMPv1/v2c/v3DHCP Server/ClientBootPTFTPSNTP
SMTPRARPRMONHTTPHTTPSTelnetSyslogDHCP Option 66/67/82SSHSNMP
InformModbus/TCPLLDPIEEE 1588 PTPIPv6
MIB
MIB-IIEthernet-Like MIBP-BRIDGE MIBQ-BRIDGE MIBBridge MIBRSTP MIB
RMON MIB Group 1, 2, 3, 9
Flow Control
IEEE 802.3x flow controlback pressure flow control
Switch Properties
Priority Queues
4
Max. Number of Available VLANs
64
VLAN ID Range
VID 1 to 4094
IGMP Groups
256
MAC Table Size
8K
Packet Buffer Size
1 MBit
Interface
Fiber Ports
1000BaseSFP-Slot
RJ45 Ports
10/100BaseT(X) oder 10/100/1000BaseT(X) auto negotiation
Console Port
RS 232 (RJ45 connector)
DIP Switches
Turbo-Ring, Master, Coupler, Reserve
LED Indicators
PWR1, PWR2, FAULT, 10/100M (TP-Port), 1000M (Gigabit-Port),
MSTR/HEAD, CPLR/TAIL
Alarm Contact
2 relay outputs with current carrying capacity of 1 A @ 24 V DC
2 inputs with the same ground, but electrically isolated from the electronics
Digital Inputs
+13 to +30 V for state 1
-30 to +3 V for state 0
Max. input current: 8 mA
Power Requirements
Input Voltage
24 V DC (12 to 45 V DC), redundant dual inputs
Input Current
IE-SW-PL10M-3GT-7TX: 0.65 A @ 24 V
IE-SW-PL10M-1GT-2GS-7TX: 0.44 A @ 24 V
Overload Current Protection
Present
Connection
2 removable 6-contact terminal blocks
Reverse Polarity Protection
Present
Physical Characteristics
Housing
Metal, IP 30 protection
Dimensions (W x H x D)
80.2 x 135 x 105 mm (3.16 x 5.31 x 4.13 in)
Weight
1170 g
Installation
DIN-Rail mounting
Environmental Limits
Operating Temperature
Storage Temperature
Ambient Relative Humidity
Regulatory Approvals
Safety
Hazardous Location
EMI
EMC
Maritime
Shock
Freefall
Vibration
MTBF (mean time between failures)
Time
204.000 hrs
Database
MIL-HDBK-217J, GB 25 C
Warranty
Warranty Period
5 years
Ordering Data
Port Variants
3 * RJ45 10/100/1000BaseT(X),
7 * RJ45 10/100BaseT(X)
1 * RJ45 10/100/1000BaseT(X),
2 * Slots 1000BaseSFP,
7 * RJ45 10/100BaseT(X)
Accessories
External Backup and
Restore Module
19'' Rack Mounting Kit
Model Type
Operating
Temperature
IE-SW-PL10M-3GT-7TX
0 to 60 C
IE-SW-PL10MT-3GT-7TX
-40 to +75 C
IE-SW-PL10M-1GT-2GS-7TX 0 to 60 C
IE-SW-PL10MT-1GT-2GS-7TX -40 to +75 C
Part No.
1241290000
1286930000
1241300000
1286940000
Model Type
EBR-Modul RS232
Part No.
1241430000
RM-KIT
1241440000
155
IE-SW-PL18M-Series
T;u\%
Technical Data
Standards
IEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT(X) and 100BaseFXIEEE 802.3ab for
1000BaseT(X)IEEE 802.3z for 1000BaseX IEEE 802.3x for Flow ControlIEEE 802.1D for Spanning
Tree ProtocolIEEE 802.1w for Rapid STPIEEE 802.1Q for VLAN TaggingIEEE 802.1p for Class of
ServiceIEEE 802.1X for AuthenticationIEEE 802.3ad for Port-Trunk mit LACP
Protocols
IGMPv1/v2GMRP, GVRPSNMPv1/v2c/v3DHCP Server/ClientBootPTFTPSNTP
SMTPRARPRMONHTTPHTTPSTelnetSyslogDHCP-Option 66/67/82SSHSNMP
InformModbus/TCPLLDPEEE 1588 PTPIPv6
MIB
MIB-IIEthernet-like MIBP-BRIDGE MIBQ-BRIDGE MIBBridge MIBRSTP MIBRMON MIB Group
1, 2, 3, 9
Flow Control
IEEE 802.3x flow controlback pressure flow control
Switch Properties
Priority Queues
4
Max. Number of Available VLANs
64
VLAN ID Range
VID 1 to 4094
IGMP Groups
256
MAC Table Size
8K
Packet Buffer Size
2 MBit
Interface
Fiber Ports
100BaseFX (SC/ST connector) and 1000BaseSFP Slot
RJ45 Ports
10/100BaseT(X) oder 10/100/1000BaseT(X) auto negotiation
Console Port
RS 232 (RJ45 connector)
LED Indicators
PWR1, PWR2, FAULT, 10/100M (TP-Port), 100M (Glasfaser-Port),
MSTR/HEAD, CPLR/TAIL
Alarm Contact
2 relay outputs with current carrying capacity of 1 A @ 24 V DC
2 inputs with the same ground, but electrically isolated from the electronics.
Digital Inputs
+13 to +30 V for state 1
-30 to +3 V for state 0
Max. input current: 8 mA
Optical Fiber
100BaseFX
multimode
singlemode
Wavelength
1300 nm
1310 nm
Max. TX
-10 dBm
0 dBm
Min. TX
-20 dBm
-5 dBm
RX Sensitivity
-32 dBm
-34 dBm
Link Budget
12 dB
29 dB
Typical Distance
5 km (50/125 m
multimode cable)
40 km (9/125 m
4 km (62.5/125 m
singlemode cable)
multimode cable)
Saturation
-6 dBm
-3 dBm
Power Requirements
Input Voltage
Input Current
Overload Current Protection
Connection
Reverse Polarity Protection
Physical Characteristics
Housing
Dimensions (W x H x D)
Weight
Installation
Environmental Limits
Operating Temperature
Storage Temperature
Ambient Relative Humidity
Regulatory Approvals
Safety
Hazardous Location
EMI
EMC
Metal, IP 30 protection
94 x 135 x 142.7 mm (3.7 x 5.31 x 5.62 in)
1630 g
DIN-Rail mounting
Standard Models: 0 to 60 C (32 to 140 F)
Wide Temp. Models: -40 to 75 C (-40 to 167 F)
-40 to 85 C (-40 to 185 F)
5 to 95 % (non-condensing)
UL 508, UL 60950-1, CSA C22.2 No. 60950-1, EN60950-1
UL/cUL Class I, Division 2, Groups A, B, C
and D; ATEX-Zone 2, Ex nC IIC
FCC Part 15, CISPR (EN55022) Class A
EN61000-4-2 (ESD), level 2; EN61000-4-3 (RS), level 3;
EN61000-4-4 (EFT), level 2; EN61000-4-5 (Surge), level 3;
EN61000-4-6 (CS), level 3; EN61000-4-8; EN61000-4-12
DNV, GL
IEC 60068-2-27
IEC 60068-2-32
IEC 60068-2-6
Maritime
Shock
Freefall
Vibration
MTBF (mean time between failures)
Time
240.000 hrs
Database
Telcordia (Bellcore), GB
Warranty
Warranty Period
5 years
Ordering Data
156
Port Variants
Model Type
IE-SW-PL18M-2GC-16TX
IE-SW-PL18MT-2GC-16TX
IE-SW-PL18M-2GC14TX2SC
IE-SW-PL18MT-2GC14TX2SC
Operating
Temperature
0 to +60 C
-40 to +75 C
0 to +60 C
-40 to +75 C
16 * RJ45 10/100BaseT(X),
2 * Kombi-Ports1
14 * RJ45 10/100BaseT(X),
2 * SC-Multimode 100FX,
2 * Kombi-Ports1
14 * RJ45 10/100BaseT(X),
2 * ST-Multimode 100FX,
2 * Kombi-Ports1
14 * RJ45 10/100BaseT(X),
2 * SC-Singlemode 100FX,
2 * Kombi-Ports1
1241320000
1286970000
1241330000
1286990000
IE-SW-PL18M-2GC14TX2ST
IE-SW-PL18MT-2GC14TX2ST
0 to +60 C
-40 to +75 C
1241340000
1287000000
IE-SW-PL18M-2GC14TX2SCS
IE-SW-PL18MT-2GC14TX2SCS
0 to +60 C
-40 to +75 C
1241350000
1287010000
(10/100/1000BaseT(X) or 100/1000BaseSFP)
Part No.
,(6:3/06HULHV
PPLQ
T;\%
PPLQ
Technical Data
PPLQ
Standards
IEEE 802.3 for 10BaseTIEEE 802.3u for 100BaseT (X) and 100BaseFXIEEE 802.3ab for
1000BaseT(X)IEEE 802.3z for 1000BaseXIEEE 802.3x for Flow ControlIEEE 802.1D for Spanning
Tree ProtocolIEEE 802.1w for Rapid STPIEEE 802.1Q for VLAN TaggingIEEE 802.1p for Class of
ServiceIEEE 802.1X for AuthenticationIEEE 802.3ad for Port Trunk with LACP
Protocols
IGMPv1/v2GMRPGVRPSNMPv1/v2c/v3DHCP Server/ClientDHCP Option
66/67/82BootPTFTPSNTPSMTPRARPRMONHTTPHTTPSTelnetSSHSyslogM
odbus/TCPSNMP InformLLDPIEEE 1588 PTPIPv6
MIB
MIB-IIEthernet-Like MIBP-BRIDGE MIBQ-BRIDGE MIBBridge MIBRSTP MIB
RMON MIB Group 1, 2, 3, 9
Flow Control
IEEE 802.3x flow controlback pressure flow control
Switch Properties
Priority Queues
4
Max. Number of Available VLANs
64
VLAN ID Range
ID 1 to 4094
IGMP Groups
256
MAC Table Size
8K
Packet Buffer Size
1 MBit
Interface
Fiber Ports
100/1000Base SFP Slot
RJ45 Ports
10/100/1000BaseT(X) auto negotiation
Console Port
RS 232 (RJ45 connector)
DIP Switches
Turbo-Ring, Master, Coupler, Reserve
LED Indicators
PWR1, PWR2, FAULT, 10/100/1000M, MSTR/HEAD, CPLR/TAIL
Alarm Contact
2 relay outputs with current carrying capacity of 1 A @ 24 V DC
2 inputs with the same ground, but electrically isolated from the electronics
Digital Inputs
+13 to +30 V for state 1
-30 to +3 V for state 0
Max. input current: 8 mA
Power Requirements
Input Voltage
12/24/48 V DC, redundant dual inputs
Input Current
0.81 A @ 24 V
Overload Current Protection
Present
Connection
2 removable 6-contact terminal blocks
Reverse Polarity Protection
Present
Physical Characteristics
Housing
Metal, IP 30 protection
Dimensions (W x H x D)
87.1 135 107 mm (3.43 5.31 4.21 in)
Weight
1510 g
Installation
DIN-Rail mounting
Environmental Limits
Operating Temperature
Storage Temperature
Ambient Relative Humidity
Regulatory Approvals
Safety
Hazardous Location
EMI
EMC
Maritime
Shock
Freefall
Vibration
MTBF (mean time between failures)
Time
330.000 hrs
Database
Telcordia (Bellcore), GB
Warranty
Warranty Period
5 years
Ordering Data
Port Variants
Model Type
4 * RJ45 10/100/1000BaseT(X)
5 * Kombi-Ports
10/100/1000BaseT(X) oder
100/1000BaseSFP
IE-SW-PL09M-5GC-4GT
IE-SW-PL09MT-5GC-4GT
Accessories
External Backup and
Restore Module
19'' Rack Mounting Kit
Operating
Temperature
0 to 60 C
-40 to +75 C
Order No.
1241370000
1287020000
Model Type
EBR-Modul RS232
Order No.
1241430000
RM-KIT
1241440000
157
Media converter
Media converter
If high interference immunity is needed or long transmission
distances are involved, then fibre-optic cables are advisable.
Another advantage of using fibre-optic cabling is the
insensitivity to lightning or voltage surges. The use of
fibre-optic based systems is already established in the
process industry, plant engineering, energy distribution and
the wind energy branches.
One simple and inexpensive solution is offered by the media
converter. This connects the Ethernet via an RJ45 port to
an optical fibre-optic cable port with SC or ST glass fibre
connections. This retains the collision domain between
the two Ethernet participants and means that there is
status transparency exchanged between the two Ethernet
interfaces and the port status.
158
,(0&9/6HULHV
PPLQ
PPLQ
T;u\%
PPLQ
Technical Data
Technology
Standards
Interfaces
Fiber Ports
RJ45 ports
DIP Switches
LED Indicators
Alarm Contact
Optical Fiber
Wavelength
Max. TX
Min. TX
RX Sensitivity
Link-Budget
Typical Distance
Approvals
Security
EMI
EMC
singlemode
1310 nm
0 dBm
-5 dBm
-34 dBm
29 dB
40 km c
Saturation
-3 dBm
a
50/125 m, 800 MHz*km fiber optic cable
b
62.5/125 m, 500 MHz*km fiber optic cable
c
9/125 m, 3.5 PS/(nm*km) fiber optic cable
Power Requirements
Input Voltage
24 V DC (12 to 48 V DC),
redundant inputs
Current consumption
0.16 A (@ 24 V)
Connection
Removable terminal block
Overload Current Protection
1.1 A
Reverse Polarity Protection
Present
Technical Data
Housing
Metal, IP 30 protection
Dimensions (W x H x D)
53.6 x 135 x 105 mm (2.11 x 5.31 x 4.13 in)
Weight
630 g
Installation
TS 35
Environmental Limits
Operating temperature
Standard Models: 0 to 60 C (32 to 140 F)
Wide Temp. Models: -40 to 75 C (-40 to 167 F)
Operating Humidity
5 to 95 % RH
Storage Temperature
-40 to 85 C (-40 to 185 F)
Hazardous Location
Maritime
Freefall
Shock
Vibration
MTBF (mean time between failures)
Time
401.000 hrs
Database
MIL-HDBK-217F: GB 25 C
Warranty
Warranty Period
5 years
Ordering Data
Port Variants
Type
1 * RJ45, 1 * SC-Multimode
IE-MC-VL-1TX-1SC
IE-MC-VLT-1TX-1SC
IE-MC-VL-1TX-1ST
IE-MC-VLT-1TX-1ST
IE-MC-VL-1TX-1SCS
IE-MC-VLT-1TX-1SCS
1 * RJ45, 1 * ST-Multimode
1 * RJ45, 1 * SC-Singlemode
Accessories
19" Rack Mounting Kit
Type
RM-KIT
Operating
Temperature
0 to +60 C
-40 to +75 C
0 to +60 C
-40 to +75 C
0 to +60 C
-40 to +75 C
Part No.
1241400000
1286880000
1241410000
1286890000
1241420000
1286900000
Part No.
1241440000
159
Serial/Ethernet converters
Serial/Ethernet Converter
Serial interfaces such as RS 232, RS 422 or RS 485 are
widespread today in automation systems. To integrate these
devices into modern Industrial Ethernets, Serial/Ethernet
converters are used which offer investment protection for
existing automation components. These devices include
control systems, sensors, meters, drives, bar code readers
and operator displays.
Weidmullers Serial/Ethernet converters connect these
devices simply and easily to existing Ethernet network
structures. The configuration of the serial port and Ethernet
port parameters is done using an internet browser.
On the Ethernet side, these devices support several
operating modes: including TCP server, TCP client, UDP,
Real COM, RFC 2217, Reverse Telnet, Pair Connection and
160
Serial/Ethernet converter
\%
105 mm (4.14 in) 8.8 mm (0.35 in)
Technical Data
Ethernet Interface
Number of Ports
Speed
Connection
Magnetic Isolation Protection
Ethernet Line Protection
Serial Interface
Number of Ports
Serial Standards
Connection
2
10/100 MBit/s, auto MDI/MDIX
8-pin RJ45
1.5 KV built-in
1 KV (level 2) surge protection
IE-CS-2TX-1RS232/485: 1,
IE-CS-2TX-2RS232/485: 2
RS 232/422/485
IE-CS-2TX-1RS232/485: DB9 for RS 232,
terminal block for RS 422/485
IE-CS-2TX-2RS232/485: DB9
for RS 232/422/485
15 KV ESD protection for all signals
1 KV (level 2) surge protection
ADDC (automatic data direction control)
5, 6, 7, 8
1, 1.5, 2
None, Even, Odd, Space, Mark
RTS/CTS and DTR/DSR (RS 232 only), XON/XOFF
50 bit/s to 921.6 kbit/s
TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
Tx+, Tx-, Rx+, Rx-, GND
Tx+, Tx-, Rx+, Rx-, GND
Data+, Data-, GND
ICMP, IP, TCP, UDP, DHCP, BOOTP, Telnet,
Rtelnet, DNS, SNMP, HTTP, SMTP, SNTP, IGMP
Web Console, Serial Console, Telnet Console,
Windows Utility
Windows 95/98/ME/NT/2000,
Windows XP/2003/Vista/2008/7 x86/x64
Metal, IP 30 protection
IE-CS-2TX-1RS232/485: 475 g
IE-CS-2TX-2RS232/485: 485 g
36 x 105 x 140 mm (1.42 x 4.13 x 5.51 in)
Standard Models: 0 to 60 C (32 to 140 F)
Wide Temp. Models:
-40 to 75 C (-40 to 167 F)
5 to 95 % RH
-40 to 85 C (-40 to 185 F)
12 to 48 V DC
IE-CS-2TX-1RS232/485: 12 to 48 V DC;
220 mA @ 12 V DC, 110 mA @ 24 V DC
IE-CS-2TX-2RS232/485: 12 to 48 V DC;
250 mA @ 12 V DC, 125 mA @ 24 V DC
Approvals
EMC
Security
Hazardous Location
ATEX
EMC
Shock
Freefall
Vibration
Reliability
Alert Tools
Automatic Reboot Trigger
MTBF (mean time between failures)
Time
Database
Warranty
Warranty Period
Pin Assignment
RS 232/422/485
PIN
DB9 male port
1
2
12345
3
4
5
6
7
6789
8
Pin Assignment
RS 422/485 Terminal
Block Wiring
1 2 3 4 5
RS 422/RS 485-4w
TxD-(A)
TxD+(B)
RxD+(B)
RxD-(A)
GND
-
RS 485-2W
Data+(B)
Data-(A)
GND
-
PIN
1
2
3
4
5
RS 422/RS 485-4w
TxD+(B)
TxD-(A)
RxD+(B)
RxD-(A)
GND
RS 485-2w
Data+(B)
Data-(A)
GND
Ordering Data
Models
Type
IE-CS-2TX-1RS232/485
IE-CST-2TX-1RS232/485
IE-CS-2TX-2RS232/485
IE-CST-2TX-2RS232/485
Accessories
19" Rack Mounting Kit
Type
RM-KIT
Operating
Temperature
0 to +60 C
-40 to +75 C
0 to +60 C
-40 to +75 C
Part No.
1242080000
1285830000
1242090000
1285840000
Part No.
1241440000
161
SFP modules
Technical Data
Technical Data
Interfaces
Ethernet Ports
Connectors
Optical Fiber
1
Duplex LC Connector or Simplex LC
Gigabit Ethernet
SFP-LHX SFP-10A SFP-10B SFP-20A SFP-20B
TX
TX
TX 1
TX
nm, 1550 nm, 310 nm, 1550 nm,
Wavelength
850 nm 1310 nm 1310 nm 1310 nm 1310
Empf.
Empf.
Empf.
Empf.
1550 nm 1310 nm 1550 nm 1310 nm
Max. TX
-4 dBm -1 dBm -3 dBm 1 dBm
-3 dBm
-2 dBm
Min. TX
-9.5 dBm - 9 dBm -9.5 dBm -4 dBm
-9 dBm
-8 dBm
RX Sensitivity
-18 dBm -19 dBm -20 dBm -24 dBm
-21 dBm
-23 dBm
Link Budget
8.5 dB
10 dB 10.5 dB 20 dB
12 dB
15 dB
10 km c)
20 km c)
Typical Distance 550 m a) 2 km b) 10 km c) 40 km c)
Saturation
0 dBm -3 dBm -3 dBm -3 dBm
-1 dBm
-1 dBm
a)
50/125 m, 400 MHz * km or 62.5/125 m, 500 MHz * km @ 850 nm multimode fiber optic cable
b)
62.5/125 m, 750 MHz * km @ 1310 nm multimode fiber optic cable
c)
9/125 m singlemode fiber optic cable
Note: The actual communication distance depends on many factors, including connector loss, cable
deployment, and the age of the cabling system. We recommend doing a link budget analysis and reserving
a 3 dB margin for such factors.
Environmental Limits
Operating temperature
Standard Models: 0 to 60 C (32 to 140 F)
Wide Temp. Models: -40 to 75 C
(-40 to 167 F)
Storage Temperature
-40 to 85 C (-40 to 185 F)
Ambient Relative Humidity
5 to 95 % (non-condensing)
Warranty
Warranty Period
3 years
Approvals
Security
UL, TUV
SFP-SX
SFP-LSX
SFP-LX
Ordering Data
162
SFP Variants
Type
IE-SFP-1GSXLC
IE-SFP-1GSXLC-T
IE-SFP-1GLSXLC
IE-SFP-1GLSXLC-T
IE-SFP-1GLXLC
IE-SFP-1GLXLC-T
IE-SFP-1GLHXLC
IE-SFP-1GLHXLC-T
IE-SFP-1G10ALC
IE-SFP-1G10ALC-T
Operating
Temperature
0 to +60 C
-20 to 75 C
0 to +60 C
-40 to 85 C
0 to +60 C
-40 to 85 C
0 to +60 C
-40 to 85 C
0 to +60 C
-40 to 85 C
Gigabit-Ethernet, Multimode,
LC Connector, 500 m
Gigabit-Ethernet, Multimode,
LC Connector, 2 km
Gigabit-Ethernet, Singlemode,
LC Connector, 10 km
Gigabit-Ethernet, Singlemode,
LC Connector, 40 km
WDM-Type, Gigabit Ethernet, LC Connector,
10 km, Tx 1310 nm, Rx 1550 nm,
must be paired with IE-SFP-1G10BLC
WDM-Type, Gigabit Ethernet, LC Connector,
10 km, Tx 1550 nm, Rx 1310 nm,
must be paired with IE-SFP-1G10ALC
WDM-Type, Gigabit Ethernet, LC Connector,
20 km, Tx 1310 nm, Rx 1550 nm,
must be paired with IE-SFP-1G20BLC
WDM-Type, Gigabit Ethernet, LC Connector,
20 km, Tx 1550 nm, Rx 1310 nm,
must be paired with IE-SFP-1G20ALC
Part No.
1241490000
1286700000
1241500000
1286710000
1241510000
1286720000
1241520000
1286730000
1241530000
1286740000
IE-SFP-1G10BLC
IE-SFP-1G10BLC-T
0 to +60 C
-40 to 85 C
1241540000
1286750000
IE-SFP-1G20ALC
IE-SFP-1G20ALC-T
0 to +60 C
-40 to 85 C
1241550000
1286760000
IE-SFP-1G20BLC
IE-SFP-1G20BLC-T
0 to +60 C
-40 to 85 C
1241570000
1286770000
Interfaces
Ethernet Ports
Connectors
Optical Fiber
1
Duplex LC Connector
Fast Ethernet
SFP-M
SFP-S
SFP-L
Wavelength
1300 nm
1310 nm
1550 nm
Max. TX
-18 dBm
0 dBm
0 dBm
Min. TX
-8 dBm
-5 dBm
-5 dBm
RX Sensitivity
-34 dBm
-34 dBm
-34 dBm
Link Budget
26 dB
29 dB
29 dB
40 km b)
80 km b)
Typical Distance
4 km a)
Saturation
0 dBm
-3 dBm
-3 dBm
a)
50/125 m or 62,5/125 m, 800 MHz * km @ 1300 nm multimode fiber optic cable
b)
9/125 m singlemode fiber optic cable
Environmental Limits
Operating temperature
-40 to 85 C (-40 to 185 F)
Storage Temperature
-40 to 85 C (-40 to 185 F)
Ambient Relative Humidity
5 to 95 % (non-condensing)
Warranty
Warranty Period
3 years
Approvals
Security
UL, TUV
Ordering Data
Port Variants
Type
IE-SFP-1FEMLC-T
Operating
Temperature
-40 to +85 C
Part No.
1241450000
IE-SFP-1FESLC-T
-40 to +85 C
1241470000
IE-SFP-1FELLC-T
-40 to +85 C
1241480000
%
Technical Data
Basic Operation
Connection
Configuration
Power Requirements
Input Voltage
Technical Data
Housing
Dimensions (W x H x D)
Weight
Mounting possibility
Cable Length
Environmental Limits
Operating temperature
Storage Temperature
Ambient Relative Humidity
Warranty
Warranty Period
Approvals
EMI
EMC
Ordering Data
Models
External Backup and Restore Module
Technical Data
RS 232-Interface with RJ45-Connector
Use the WEB-Console of managed Switches
3 to 5 V DC (through the RS 232 ports RTS signal)
Technical Data
Dimensions (W x H x D)
Ordering Data
Models
19" Rack Mounting Kit
Type
RM-KIT
Part No.
1241440000
Type
EBR-Modul RS232
Part No.
1241430000
163
Product Overview
164
Wireless I/O
Wireless Gateways
Wireless Modems
Product Overview
Exception Example
Peer-to-peer
networking
for maximum
network flexibility
Each Weidmuller
wireless gateway and
transceiver unit can
transmit/receive
directly to/from
any other wireless
gateway and
transceiver, and can
Peer-to-Peer Example
transmit/receive
to/from multiple
wireless units. There are no master units and no slaves.
Any module in a network can talk to any other. Input
signals can be transmitted to multiple destinations.
Wireless mesh structure
WIB-net enables every Weidmuller wireless gateway/
transceiver to act as a repeater to optimize wireless
message propagation. Messages can hop through
multiple gateway/transceiver units to reach a destination.
If these units have a reliable wireless link to at least one
other gateway/transceiver, a wireless mesh forms to
enable reliable links to the
whole network.
High security encryption
WIB-net uses a highly secure data encryption technique
to protect against misuse of wireless data. Weidmuller
wireless networks security matches or exceeds that of
wired networks.
Event-driven communication
Mesh Example
165
Product Overview
Input/Output Mapping
Process signals or sensors convey the value of an input value
to a designated output channel:
System address (15-bit, 1 32768)
Source module address (1 127)
Destination module address (1 127)
Repeater addresses (up to 5 addresses)
Output channel number
I/O signal value (16-bit)
CRC error-checking (16-bit)
All modules in the same system share a unique system
address to avoid cross-talk between systems in the same
radio environment. The configuration software automatically
generates a random system address for each system.
Destination or repeater modules automatically acknowledge
messages when received with a correct error-check value,
except for messages from transmit-only units. If an acknowledgement is not received within 500 milliseconds, the
message is re-transmitted. The message will be transmitted
up to five times with random re-try times. After the fifth
attempt, a comms-fail event will be set, which can be used
to trigger an output alarm or register.
Block Messages
Block messages are similar to other transmissions.
However, signal information is condensed into blocks
and these blocks are sent at programmed intervals. Each
block message contains up to 64 x 16-bits of values. Block
messages are only transmitted or repeated by the wireless
gateway product range (D2 W GMD).
Discrete/digital values can be packed [i.e. up to 1024
(64 x 16)] into a block message and unpacked at the
destination gateway.
Block messaging creates a more robust, reliable,
and efficient system by reducing the chance that
messages will become corrupt, and by minimizing radio
frequencycongestion.
Message Control
The WIB-net protocol is based on exception-reporting for
optimum performance. Messages can be triggered by any of
the following:
Exception change in input value compared to userconfigurable sensitivity values
Update time user-configurable time period since the last
message, individually configured for each I/O register
Real time block mappings only; messages transmitted
on real time values
On demand block mappings only; poll command from
another wireless unit or write command by a connected
databus device
166
Application Notes
Application Notes
Factors Affecting Distance & E.R.P
Frequency (as frequency increases, distance
decreasesproportionally)
Receiver sensitivity, antenna gain, cable loss
Noise / interference (the noisier the environment the more
careful you have to be with antenna placement)
Transmitter power, antenna gain, cable loss
Attenuation of radio signal
Heights of antennas, Obstructions in radio path
Other factors Atmospheric, Ground Mineralisation
In most applications it is desirable to have an overall dB
gain as opposed to a loss to ensure good communication
between radios.
Gain Sources
Radios
Antennas
Points of Loss
Connection points
Jumper cables
Surge Protection
Bulkhead adapters
WIBnet
WIBnet makes use of all the standard features of the
Weidmuller Wireless radios.
Exception-reporting transmission for maximum
wirelessefficiency.
Wireless messages are only transmitted whenever a signal
value changes, yielding effective real-time performance.
Error-checking with automatic re-transmission for high
reliability operation.
Listen-before-transmit wireless operation to maximize the
chance of successful transmission.
Peer-to-peer networking, giving the maximum
network flexibility.
WIBnet communications protocol is specifically
designed for
highly reliable and secure operation on open
license-free radio bands.
Modbus Profibus
DF1
Ethernet IP
DeviceNet
I/O
Messages can hop through multiple units to reach a destination providing each Wireless
I/O unit has a reliable wireless link to at least one other unit. A wireless mesh forms to
ensure reliable links are established within the whole network.
Mass
I/O
...
I/O
Monitoring
I/O
Modbus Profibus
DF1
Ethernet IP
DeviceNet
167
Wireless I/O
Wireless Meshing I/O Units
Weidmullers WI-I/O-9-U2 combines multi I/O and/or gateway functionality with
the reliability of secure, scalable mesh distance communications. The WI-I/O-9-U2
IP-based addressing provides mesh/self-healing of network communications,
multihop repeating and remote over the air re-configuration and diagnostics. The
WI-I/O-9-U2 is further complemented by its ease of commissioning and integration
into existing plant infrastructure.
Features:
902-928MHz Frequency Shift Keying (FSK): Frequency Hopping Spread
Spectrum Channels/Hop Sets: 50 x 250kHz; 2 frequency channels.
IP Based Wireless MESH Technology @ 1 Watt transmit power.
Self-healing, repeatable, secure communications to 128bit AES
User friendly operation with self discovery of radio path and expansion I/O
Remote over the air re-configuration, firmware upgrade and fault analysis
Scalable, simple to complex, and point to multipoint network design
Block Mapping and Block Messaging technology for ease of system integration
I/O and/or gateway functionality via feature key upgrade
System wide view, localized I/O referencing, and printing/exporting
of configuration
WI-I/O-9-U2 TC
The WI-I/O-9-U2 TC is a thermocouple adapter interface
for the WI-I/O-9-U2 product. The WI-I/O-9-U2 TC provides
greater accuracy by allowing calibration between the
adapter, measurement devices and ambient temperatures.
Temperature measurement accuracy depends on the
measured temperature and ambient temperature. Errors
are a result of both errors in cold junction temperature and
thermocouple voltage measurement. The WI-I/O-9-U2 TC
provides for greater accuracy by allowing calibration of the
cold junction temperature offset value and thermocouple
temperature (i.e. offset calibration).
Dimensions
6.49"
(168 mm)
6.97"
(177 mm)
168
(35 mm)
5.91"
(150 mm)
Radio network efficiency and commissioning of the WI-I/O9-U2 into legacy process control/automation networks is
aided with block mapping and block messaging technology.
Block mapping technology allows end-users to gather
related, non-contiguous data points/registers, into a single
radio message structure and scatter these points at receiving
devices for ease of integration (eg PLC logic, SCADA tags).
Block Mapping Technology
1 Message
Process network
Block messaging communicates continuous blocks of data improving
the efficiency of radio band use and even more scalable network design.
Remote LAN
Automatic
detection
of expansion I/O
169
WI-I/O-9-U2
C1D2
US
Technical Data
Inputs
Digital: opto-isolated (5kV) inputs suitable for voltage free contacts
or NPN transistor
Analog:
floating differential inputs, common mode voltage 27V, 24VDC for
powering external loops provided, digital filtering 1 sec.
Pulse: (configurable Digital Inputs)
Outputs
Digital
Up to 8 DI (Configurable),
On-state Voltage <2.1V Wetting, Current 5mA
4 AI (2 differential: 2 single ended)
resolution 14bits; accuracy 0.1%
Current Range - 0-24mA
Voltage Range: AI 1,2: 0-25V, AI 3,4: 0-5V
4 PI
DI 1,2: Max. Pulse rate 50kHz, Pulse width min 10us
DI 3,4: Max. Pulse rate 1kHz, Pulse width min 0.2ms
Up to 8 DO (Configurable)
FET (30V DC @ 200mA max.)
On-state Voltage - DO Max: 30 V DC
Wetting Current - DO Max: 200mA
Analog: current sink to common, max loop voltage 27V, max loop
resistance 1000 ohms
2 AO 0-24mA;
resolution 13bits; accuracy 0.1%
Pulse:
FET 30VDC 200mA max 10kHz
4 PO
DO 1, 2 Max. Pulse rate 50kHz, Pulse width min. 10s
DO 3, 4 Max. Pulse rate 1kHz, Pulse width min 0.2ms
Power Supply
Battery supply
Normal supply
Battery charging circuit
Average Current Draw
Transmit Current Draw
Internal monitoring
Notes
Connections
RS232/RS485
RS232 connection
RS485 connection
Ethernet Port
USB Port
General Data
Frequency
Transmit Power
Transmission
Modulation
Receive Sensitivity
Channel Spacing
Data Rate
Range (LoS)
Operating Temperature
Humidity
EMC Standards
Mounting
LED indication
Antenna connector
Dimensions mm (in)
Approvals
12-15V DC
15-30V DC, over-voltage and reverse power protected
included for 1.2-12 AHr sealed battery
220mA @ 12V DC (Idle), 110mA @ 24V DC (Idle)
500mA @ 12V DC (1W), 250mA @ 24V DC (1W)
power fail and battery voltage
An internal DC/DC converter provides 24V DC 150mA for analog loop
supply.
serial port 9600 baud, 8 bits, no parity, 1 stop bit
EIA-562 (RJ45 connector)
max cable distance 2000 m terminal connections
10/100 BaseT; RJ45 - IEEE 802.3
USB-B connector for configuration
902-982MHz
1mW (+0dBm) to 1W (+30dBm)
Frequency Hopping Spread Spectrum (FHSS)
Frequency Shift Keying (FSK)
-109dBm @ 19.2Kbps (3% FER)
50 x 250 KHz
19.2-115.2 Kbps Auto Mode selects fastest rate possible relative
to RSSI
32Km (20 mi.) @ 1W
-40 to 60C (-40 to 140F)
0-99%RH
EN 300 683; FCC Part 15; AS 3548; 89/336/EEC
DIN-rail mounting
Power, RF, RS232, RS485, D I/O (P I/O), A I/O
1 x SMA female coaxial
180 x 150 x 35 (5.91 x 7.09 x 1.38)
Class 1 Div 2 , CE, IEC60950, IECex
C
US
Ordering Data
Ordering Data
Wireless Mesh I/O 8 DI/O, 4AI, 2AO, 1-4 PI/O
Modbus TCP/RTU Gateway (software Add-on)
TCP Adaptor (Type T Thermocouple Add-on)
170
Type
WI-I/O-9-U2
WI-I/O 9-U2-GTWY
WI-I/O 9-U2 TC
Part No.
6720005011
6720005012
6720005013
Unidirectional Transmitter/
Receiver Units Introduction
Wireless Input/Output (I/O)
Wireless I/O connects directly to analog, discrete and pulse
transducer signals. The signals are transmitted by radio and
either re-created as output signals, or output via serial link or
field-bus.
Weidmuller Wireless I/O units have the ability to form
sophisticated peer-to-peer networks, with event-reporting
messaging to optimize wireless density. Weidmuller
products are designed for high reliability operation on open
license-free radio bands.
WI-I/O 9-L Unidirectional
Transmitter/Receiver Units
The Unidirectional Wireless I/O range of products is suitable
for connecting to a single sensor or group of sensors and
provides an economical solution for remote monitoring
systems. The Unidirectional L products can also be used in
more complex networks as signal transmitters or receivers.
Frequency hopping spread spectrum 902-928 MHz 1W
license-free USA/Canada/Mexico
Configurable sub-bands license-free South America,
Australia/NZ, Asia, Europe
Applications
Wireless connection of flowmeters or energy meters
Monitoring storage tanks
Monitoring cathodic protection on pipelines
Wireless alarms from power reticulation fault relays
Digital Analog
Thermocouple
US
Digital Analog
Features
Matched transmitter/receiver pair of modules,
or individual transmitter and receiver units
Peer-to-peer communications. Exception reporting.
Reliable self-checking messages. Highly secure data
encryption.
Multi-hop repeater functions - up to 5 intermediate units
can be configured in any input-output link
Factory configured as a matched Transmitter/Receiver
pair or user-configurable with E-Series Windows
configuration program
Transmitter unit
Input-only transmitter unit - two digital/pulse inputs, one
analog input and one thermocouple mV input
Transmits to Receiver unit as a matched pair where the
input signals are re-created as output signals, or can
transmit to a Multi-I/O or Gateway unit
171
Receiver unit
Output-only receiver unit - three digital contact outputs
and one analog output
Receives radio commands from Transmitter unit as a
matched pair where the input signals are re-created as
output signals, or can receive commands from a Multi-I/O
or Gateway unit
Class 1 Div 2 hazardous areas approval
Up to 3000 wireless units per network
Power supply 9 30Vdc; 24Vdc analog loop supply
internally provided
Communications failure indication and
configurableoutput
Outputs can be configured as retained or reset (fail-safe)
on communications failure
LED indication of radio signal strength
RS232 Configuration and diagnostics port
C
US
Dimensions
Temperature: -40 to 60C / -40 to 140F
Humidity: 0 - 99% RH
Regulatory Approvals: EMC compliant 89/336 EEC,
EN 301 489, AS3548, FCC Part 15, Approved to FCC
Part 15.247, RS210
Housing: DIN rail thermo-plastic enclosure 100 x 22 x
120 mm / 3.9 x 0.9 x 4.7 inches
Transmitter Unit: Power/OK, radio TX, DIN1, DIN2,
analog set-point status
Receiver Unit: Power/OK, radio RX, DO1, DO2, DO3,
communications fail LEDs also used to provide radio
signal strength indication
WI-I/O 9-L-T
OK
D1
D2
SP
TX
AZ
PG
3.9"
(100 mm)
SET
6720005005
4.7"
(120 mm)
Transmitter Inputs
.09"
(23 mm)
General
Frequency: frequency hopping spread spectrum
902-928MHz, sub-bands available, 1W
Sensitivity: line-of-sight range 20 miles (4W ERP effective radiated power), 15km (1W ERP); 3000 ft
/1000 m in obstructed industrial environments; radio
distances can be increased by up to 5 intermediate
transceiver or gateway units
Antenna Connector: SMA connector for antenna or
coaxial cable connection
172
Input Type
Digital
Pulse Total
Analog
Thermocouple
Set Point
Supply Voltage
Source
external
external
external
external
internal
internal
Function
status
count
analog
analog
status
analog
LED Indication
Transmitter Unit
Analog Inputs
0-20 mA (4-20mA, 0-10mA)
Floating differential input, resolution 16-bit,
accuracy < 0.1 %
Thermocouple Inputs
Millivolt (-10mV to +100mV), J, K, or T type linearization
with on-board cold-junction compensation
Accuracy better than 1C
Power Supply
Normal Supply: 9 - 30 VDC, power consumption
@12VDC - receiver normal 70mA, max. 250mA
Transmitter normal 70mA, transmitting max. 600mA
Analog loop supply internally generated, 24VDC 35mA
Internal monitoring of supply voltage may be transmitted
as an input (transmitter unit only)
Set-point Status
High and low set-points generate internal digital statusset-point status sets (on) when analog value < low setpoint and resets (off) when analog value > high set-point.
Status is transmitted as per digital input, set-point values
are set via the front panel rotary switch or configuration
software.
Separate set-points for (4-20 mA), thermocouple and
supply inputs are configurable
Receiver Outputs
Digital Outputs
Three relay contact outputs, 260V 1A
Analog Outputs
0-20mA, source output, 12-bit resolution,
0.1% accuracy
Communication Failure
Internal status based on configurable time-out value
Comms-fail status can be configured to a local output
Fail-Safe
On comms-fail, outputs user-configurable as retained
last correct value or reset (fail-safe)
Serial Port
RS232 RJ45 female DCE, used for configuration
and diagnostics
173
C1D2
US
Technical Data
Transmitter Inputs:
Digital:
Pulse:
Analog:
floating differential input:
resolution
accuracy
Thermocouple
Accuracy
Receiver Outputs
Digital
Analog
resolution
accuracy
Comms-Fail
Fail-safe
Power Supply
Power consumption @12VDC
9-30 VDC
Receiver 100mA, Transmitter 40mA quiescent,
during radio transmission (50 msec) 300mA
24VDC 30mA
may be transmitted as an input (Transmitter unit only)
Antenna connector
Dimensions mm (in)
Configuration
Diagnostics
Type
Type
Ordering Data
Accessories: DB9 Female-RJ45 Serial configuration cable
174
WI-I/O 9-L-T
WI-CSER-RJ45
Part No.
6720005005
6720005108
WI-I/O 9-L-R
WI-CSER-RJ45
Part No.
6720005006
6720005108
WI-I/O 9-L-P1
Set - 1 Transmitter, 1 Receiver
WI-I/O 9-L-P2
Set with 2 WI-ANT-DPL-0-8
two inputs, suitable for voltage free contacts / NPN, or voltage input
0-1 VDC on / >3 VDC off
max rate 10 Hz, 50 msec on time. Pulse counted as16 bit register.
0-20 mA (4-20mA, 0-10mA)
16 bit
< 0.1 %
Millivolt (-100mV to +100mV), J, K or T type linearization with on-board
cold-junction compensation
greater than 1C
three relay contact outputs, 260V 1A
0-20mA
12 bit
0.10%
Internal status based on configurable time-out value. Comms-fail status
can be configured to a local output.
On comms-fail, outputs user-configurable as retained (last correct
value) or reset (fail-safe)
9-30 VDC
Receiver 100mA, Transmitter 40mA quiescent,
during radio transmission (50 msec) 300mA
24VDC 30mA
may be transmitted as an input (Transmitter unit only)
16 bit
< 0.1 %
Millivolt (-100mV to +100mV), J, K or T type linearization with on-board
cold-junction compensation
greater than 1C
three relay contact outputs, 260V 1A
0-20mA
12 bit
0.10%
Internal status based on configurable time-out value. Comms-fail status
can be configured to a local output.
On comms-fail, outputs user-configurable as retained (last correct
value) or reset (fail-safe)
9-30 VDC
Receiver 100mA, Transmitter 40mA quiescent, during radio
transmission (50 msec) 300mA
24VDC 30mA
may be transmitted as an input (Transmitter unit only)
Type
WI-I/O 9-L-P1
Two -2 dB Dipole antennas (6720005086)
Two 3 ft. antenna connecting cables/brackets
One configuration cable
Type
Part No.
WI-I/O 9-L-P2
6720005008
Two 0 dB Dipole antennas (6720005080)
Two 15 ft. antenna connecting cables/brackets
One configuration cable
C1D2
US
Technical Data
Transmitter Inputs:
Digital:
Pulse:
Analog:
floating differential input:
resolution
accuracy
Thermocouple
Accuracy
Receiver Outputs
Digital
Analog
resolution
accuracy
Comms-Fail
Fail-safe
Power Supply
Power consumption @12VDC
Analog loop supply internally generated
Internal monitoring of supply low voltage status
Power consumption increases for pulse inputs > 10Hz.
Serial Port
General Data
Operating Temperature
Humidity
EMC Standards
Mounting
LED indication: Transmitter Unit
LED indication: Receiver Unit
frequency hopping spread spectrum
Transmit power
Maximum line of sight range
Antenna connector
Dimensions mm (in)
Configuration
Diagnostics
Ordering Data
Kit Contents
Part No.
6720005007
175
Typical Applications
Wireless junction box in a process plant to connect a
large number of signals to other parts of the plant and to
the plant control center
Simple Remote Terminal Unit (RTU) in a SCADA system,
connecting sensors/instrumentation/process signals
in pump stations, sub-stations, pipeline regulator
stations,etc.
Machine-to-Machine wireless connectivity in factories
Features
Class I, Division 2 hazardous areas approved
(USA/Canada); (CSA certified)
Multiple inputs/output channels for monitoring
and control functions
Up to 95 wireless units per network
Each wireless unit can connect to input/output
expansion modules via RS485 multi-drop with up
to 31 expansion modules per wireless unit
Sensor signals connected at one module; input
signals are transmitted to another module where
the signals are re-created as output signals or
passed via serial to a host device such as a PLC
or SCADA system
176
Gas
Analyzer
Metering
ALARM
PLC
Alarms
Plant
Control
Gauges
-1
-2
-3
-4
Digital inputs
4
Voltage-free contacts
4
Voltage-free contacts
0
Voltage-free contacts
4 16
Voltage-free contacts
Relay + FET
FET
FET
FET
4-20mA
0-20mA/0-10V
4-20mA
0-20mA/0-10V
100Hz
1 x 1KHz, 3 x 100Hz
1 x 1KHz, 3 x 100Hz
100Hz
1 x 1KHz, 3 x 100Hz
1 x 1KHz, 3 x 100Hz
Digital outputs
Analog inputs
Analog outputs
Pulse inputs
Pulse outputs
1 + 3
4 - 16
0
4
4
Dimensions
6.57"
(167 mm)
7.4"
(188 mm)
(55 mm)
2.4"
(60 mm)
5.1"
(130 mm)
General
Frequency: frequency hopping spread spectrum
902-908 MHz, sub-bands configurable
Power: transmit power 1W, approved to FCC
Part 15.247, RSS210
Sensitivity: receiver data sensitivity 108dBm
Max. Range (line-of-sight): USA/Canada - 4W ERP,
20+ miles. Other countries - 1W ERP, 15+ km depending
on local conditions
Data Rate: 19.2 Kb/s with forward-error correction
Antenna Connector: SMA female coaxial
Temperature: -40 to 60C / -40 to 140F
Humidity: 0-99% RH
Digital Outputs
Type-1 - four relay, contacts, Form A, AC 50V 5A / DC
30V 2A
Type-2 - 1 FET output 30VDC 500mA
Type-3 - 8 FET output 30VDC 500mA
Type-4 - up to 16 FET output (4 outputs +
12 selectable I/O)
Analog Inputs
Floating differential inputs, common mode voltage
27V. 24VDC for powering external loops provided.
Digital filtering 1 sec.
Type-1 - two 4-20mA resolution 15-bit, accuracy 0.1%
(over range indication 2-25mA)
Type-2 - six 0-20mA resolution 12-bit, accuracy 0.1%
(over range indication 0-25mA)
177
Analog Outputs
Current sink to common, max. loop voltage 27V, max. loop
resistance 1000 ohms
Type-1 - two 4-20 mA resolution 15-bit, accuracy 0.1%
(over range indication 0.5-25mA)
Type-3 - eight 0-20 mA resolution 12-bit, accuracy 0.1%
(over range indication 0-20.5mA)
Pulse Inputs
Specifications as per digital inputs, max. pulse rate 100Hz,
pulse width min. 5 ms
Type-1 - one input (DI1)
Type-2 - four inputs (DI1-4) - first pulse input (DI1) max.
1000Hz, pulse width min. 0.5 ms
Type-4 - four inputs (DI1-4) - first pulse input (DI1) max.
1000Hz, pulse width min. 0.5 ms
Pulse Outputs
FET 30VDC 500mA max. 100Hz
Type-1 - one
Type-3 & -4 - four
Power Supply
Battery Supply: 11.5-15.0 VDC
Normal Supply: 12-24 VAC or 15-30 VDC, over-voltage
and reverse power protected
Internal monitoring of power fail, solar charge status,
and battery voltage. These values may be transmitted to
remote modules for monitoring.
Internal DC/DC converter provides 24VDC 150mA for
analog loop supply
Battery charging circuit included for 1.2-12 AHr
sealedbattery
Solar regulator for direct connection of solar panel
(up to 30W) and solar battery (100AHr)
Serial Port
A serial port can be used to configure transceivers and
to hard wire one transceiver to another when desired.
This connection avoids the need to add wireless nodes
to circumvent impenetrable obstructions, and provides a
redundant path for critical applications.
RS232/RS485 serial port 9600 baud, 8 bits, no parity,
1 stop bit
RS232 9 pin DB9 female connector
RS485 terminal connections (max. cable distance 2000m)
178
WI-I/O 9-2
WI-I/O 9-1
C1D2
US
Technical Data
Inputs
Digital: opto-isolated (5000V) inputs suitable for voltage free contacts
or NPN transistor, contact wetting current 5 mA
Analog: floating differential inputs, common mode voltage 27V,
24VDC for powering external loops provided, digital filtering 1 sec.
Pulse: as per digital inputs,
Max pulse rate 100Hz, pulse width min 5ms
Outputs
Digital
Analog: current sink to common, max loop voltage 27V, max loop
resistance 1000 ohms
Pulse: FET 30VDC 500mA max 100Hz
Power Supply
Battery supply
Normal supply
Battery charging circuit
Solar regulator
Internal monitoring
Notes
Serial Port
RS232/RS485
RS232 connection
RS485 connection
General Data
Operating Temperature
Humidity
EMC Standards
Mounting
LED indication
Antenna connector
Dimensions mm (in)
Approvals
four inputs
four inputs
one
11.5-15.0 VDC
12-24 VAC or 15-30 VDC, over-voltage and
reverse power protected
included for 1.2-12 AHr sealed battery
for direct connection of solar panel (up to 30W)
and solar battery (100AHr)
power fail, solar charge status, and battery voltage
An internal DC/DC converter provides 24VDC 150mA for analog loop
supply.
11.5-15.0 VDC
12-24 VAC or 15-30 VDC, over-voltage and
reverse power protected
included for 1.2-12 AHr sealed battery
for direct connection of solar panel (up to 30W)
and solar battery (100AHr)
power fail, solar charge status, and battery voltage
An internal DC/DC converter provides 24VDC 150mA for analog loop
supply.
US
US
Ordering Data
Type
Accessories: DB9 Male - DB9 Female Serial config. cable
WI-I/O 9-1
WI-CSER-905-9
Part No.
6720005000
6720005105
Type
WI-I/O 9-2
WI-CSER-905-9
Part No.
6720005001
6720005105
179
WI-I/O 9-3
WI-I/O 9-4
C1D2
US
Technical Data
Inputs
Digital: opto-isolated (5000V) inputs suitable for voltage free contacts
or NPN transistor, contact wetting current 5 mA
Analog: floating differential inputs, common mode voltage 27V,
24VDC for powering external loops provided, digital filtering 1 sec.
Pulse: as per digital inputs,
Max pulse rate 100Hz, pulse width min 5ms
Outputs
Digital
Analog: current sink to common, max loop voltage 27V, max loop
resistance 1000 ohms
Pulse: FET 30VDC 500mA max 100Hz
Power Supply
Battery supply
Normal supply
Battery charging circuit
Solar regulator
Internal monitoring
Notes
Serial Port
RS232/RS485
RS232 connector
RS485 connector
General Data
Operating Temperature
Humidity
EMC Standards
Mounting
LED indication
Antenna Connector
Dimensions mm (in)
Approvals
four (DO1-4)
four (DO1-4)
11.5-15.0 VDC
12-24 VAC or 15-30 VDC, over-voltage
and reverse power protected
included for 1.2-12 AHr sealed battery
for direct connection of solar panel (up to 30W)
and solar battery (100AHr)
power fail, solar charge status, and battery voltage
An internal DC/DC converter provides 24VDC 150mA for analog
loop supply.
11.5-15.0 VDC
12-24 VAC or 15-30 VDC, over-voltage
and reverse power protected
included for 1.2-12 AHr sealed battery
for direct connection of solar panel (up to 30W)
and solar battery (100AHr)
power fail, solar charge status, and battery voltage
An internal DC/DC converter provides 24VDC 150mA for analog
loop supply.
US
US
Ordering Data
Type
Accessories: DB9 Male - DB9 Female Serial config. cable
180
WI-I/O 9-3
WI-CSER-905-9
Part No.
6720005002
6720005105
Type
WI-I/O 9-4
WI-CSER-905-9
Part No.
6720005003
6720005105
WI-I/OEX
Expansion I/O Units (Serial I/O)
The WI-I/O-EX is a wired device capable of
interfacing with other Weidmuller wireless
radios to increase the number of signals
radios can monitor/control. They can also
be used as a slave to any Modbus control
system.
Typical Applications
Expansion I/O for WI-I/O 9 wireless
units and WI-MOD units
up to 31 x WI-I/O-EX units can be connected to each
wireless unit via RS485 (up to 2 km long). Serial I/O
multiplexer
transfer I/O via RS485 up to 32 units per multi-drop link.
Expansion I/O for Modbus devices
up to 31 x WI-I/O-EX units can be connected to each
Modbus master via RS485 (up to 2 km long).
I/O
I/O
RS485
I/O
Connect up to 99 x WI-I/O-EX
units as multi-drop Modbus
I/O (RS485 extenders/isolators
required for more than 31units
per single multi-drop length)
RS485 multi-drop up to 2 km
(1 mile) depending on installation
RS485
environment
Three I/O versions available
Peer-to-peer communications;
Up to 32 Units
Exception reporting; Reliable selfchecking messages; Any input
on any unit can be linked to any
output on any unit. Inputs can be
linked to multiple outputs; Serial
communications 9.6Kb/s
Alternate Modbus RTU or Modbus
ASCII slave protocol, serial communications configurable
up to 115.2Kb/s, 7or 8 data bit format
External I/O plus internally calculated values - analog
setpoint status, pulse rate and pulse total, power supply
voltage, power supply alarm
Setpoint status generated by comparing analog inputs to
high and low setpoints
I/O
RS485
I/O
I/O
I/O
Data
Bus
I/O
Features
Multi I/O channels monitoring and control functions
Connected via RS485 multi-drop
Selectable communications via WIB-net or Modbus
protocol (both RTU and ASCII formats)
Sensor signals connected at one module (input signals)
are transmitted to another module where the signals are
re-created as output signals, or passed via serial to a host
device such as a PLC or SCADA system
Connect to WI-I/O 9 wireless I/O units for up to 31 serial
addresses per wireless unit
Connect WI-I/O-EX units together to form a serial
multi-drop I/O system - up to 32 serial addresses
per multi-drop link no Master device is required to
controlcommunications
I/O
I/O
181
US
up to 16
up to 16
0
0
4
1KHz
8
100Hz
up to 8
Voltage-free contacts
up to 8
4 floating/ 8 commoned
0-20mA / 0-10V
0
0
up to 8
8 sink / source
0-20mA / 0-10V
0
8
100Hz
8
100Hz
up to 8
0
Note: Digital inputs and outputs are combined channels. When a channel is used as an output, it is not available as an input. Pulse and digital I/O are same connection.
Dimensions
General Specifications
6.49"
6.97"
(168 mm)
(177 mm)
1.38"
(35 mm)
5.91"
(150 mm)
182
Pulse Inputs
Digital Inputs
Pulse Outputs
Specifications as per digital outputs, max. pulse
rate100Hz, pulse width min. 5ms
Type -11,-12,-13, - 8 outputs (DIO1-8)
Power Supply
Battery Supply: 9 - 30VDC, over-voltage and reverse
power protected
Internal monitoring of supply voltage. These values may
be transmitted to remote modules for monitoring.
Internal DC/DC converter provides 24VDC 250mA for
analog loop supply
Serial Port
RS485 serial port configurable up to 115.2Kb/s, 7 or 8
data bits, none/even/odd parity, 1 or 2 stop bits
RS232 configuration port 9 pin DB9 female connector,
9.6Kb/s, 8/n/1
RS485 max cable distance 2000m terminal connections
183
WI-I/O-EX-1-S-11
WI-I/O-EX-1-S-12
up to 16 selectable I/O
up to 8 selectable I/O
4 inputs (DIO1-4)
up to 16 selectable I/O
8 outputs (DIO1-8)
up to 8 selectable I/O
8 outputs (DIO1-8)
C1D2
US
Technical Data
Inputs
Digital: suitable for voltage free contacts or NPN transistor, contact
wetting current 5mA, inputs are surge protected
Analog: floating differential inputs, common mode voltage 27V, 24VDC for
powering external loops provided, 0-20mA/0-10V resolution 12 bit, accuracy
0.1%
Pulse: specifications as per digital inputs Max pulse rate 1kHz, pulse
width min 0.5ms
Outputs
Digital: FET outputs, 30VDC 200mA
Pulse: specifications as per digital outputs
Max pulse rate 100Hz, pulse width min 5ms
Power Supply
Serial Port
RS485
RS232 connector
RS485 connector
General Data
Operating Temperature
Humidity
EMC Standards
Mounting
LED indication
Dimensions mm (in)
Approvals
US
US
Ordering Data
Type
WI-I/O-EX-1-S-11
184
Part No.
6720005038
Type
WI-I/O-EX-1-S-12
Part No.
6720005039
WI-I/O-EX-1-S-13
C1D2
US
Technical Data
Inputs
Digital: suitable for voltage free contacts or NPN transistor, contact
wetting current 5mA, inputs are surge protected
Outputs
Digital: FET outputs, 30VDC 200mA
Analog: selectable as current/voltage source or current sink to
common, max loop voltage 27V, max loop resistance 1000 ohms, 0
20mA/0 10V, 12 bit, accuracy 0.1%
Pulse: specifications as per digital outputs
Max pulse rate 100Hz, pulse width min 5ms
Power Supply
Serial Port
RS485
RS232 connector
RS485 connector
General Data
Operating Temperature
Humidity
EMC Standards
Mounting
LED indication
Dimensions mm (in)
Approvals
up to 8 selectable I/O
up to 8 selectable I/O
8 channels
8 outputs (DIO1-8)
10.8 - 30VDC, over-voltage and reverse power protected. Internal
monitoring of supply voltage. These values may be transmitted to
remote modules for monitoring. An internal DC/DC converter provides
20VDC 150mA for analog loop supply.
serial port configurable up to 115.2Kb/s, 7/8 data bits, n/e/o parity,
1 / 2 stop bits
configuration port 9pin DB9 female connector, 9.6Kb/s, 8/n/1
max cable distance 2000 m terminal connections
-40 to 60C (-40 to 140F)
0-99% RH
FCC Part 15, AS3548, 89/336/EEC
DIN rail mounting
power supply, processor OK, serial TX and RX,
digital I/O
150 x 177 x 35 (5.91 x 6.97 x 1.38)
Class 1 Div 2 hazardous areas
C
US
Ordering Data
Type
WI-I/O-EX-1-S-13
Part No.
6720005040
185
Digital
Analog
Pulse
Digital
Analog
Pulse
Direct I/O
Direct I/O
PC
DCS
SCADA
PLC
Features
Input-only unit - two digital/pulse one analog
Networks with Multi-I/O and Gateway units
Analog Loop Supply for field devices
Sensor signals (inputs) are transmitted to a Multi-I/O
module where the signals are re-created as output
signals, or passed via serial or Ethernet data bus to a host
device such as a PLC or SCADA system.
Extremely low power consumption by reverting to sleep
mode
Multiple power supply options including battery-only
supply
Weatherproof IP66 / NEMA 4 enclosures
Class 1 Div 2 hazardous areas approval
Up to 3000 wireless units per network
Any input on any unit can be wirelessly linked to any
output on any unit. Inputs can be linked to multiple
outputs.
Peer-to-peer communications. Exception reporting.
Reliable self-checking messages. Highly secure data
encryption.
C
186
US
Direct I/O
Dimensions
Digital Inputs
Two inputs, suitable for voltage-free contacts / NPN, or
voltage input 0-1 VDC on / >3 VDC off
Status transmission on change of input signal and on time
elapsed since last transmission - update time period 10
sec. - 5 days, a separate update time can be configured
when the discrete input is on
5.1"
(150 mm)
6.7"
(170 mm)
Pulse Inputs
1.4"
(36 mm)
2.5"
(64 mm)
General Specifications
Frequency: frequency hopping spread spectrum
902-928MHz, sub-bands available
Power: 1W
Max. Range (line-of-sight): 20 miles (4 ERP),
15km (1 ERP); 3000 ft / 1000 m in obstructed
industrialenvironments
Antenna Connector: SMA connector
Temperature: -40 to 60C / -40 to 140 F
Humidity: 0-99% RH
Regulatory Approvals: approved to FCC Part15.247,
RS210; EMC compliant 89/336 EEC, EN 300 683,
AS3548, FCC Part 15
Housing: weatherproof (IP66) painted aluminum
enclosure 170 x 64 x 36mm/ 6.7 x 2.5 x 1.4 inches;
weatherproof connector for external connections
Each transmission may be configured to be sent 1 to 5
times
LED indicators - radio TX, operation OK
High and low set-points generate internal digital status.
Set-point status sets (on) when analog value <low setpoint and resets (off) when analog value > highset-point
status transmitted as per digital input.
Input Type
Source
Function
Digital
Pulse Total
Pulse Rate
Analog
Set-point
Supply Voltage
Supply Low Voltage
external
external
internal
external
internal
internal
internal
status
count
analog
analog
status
analog
status
187
Battery Pack
Specifications
WI-BP-I/O-9-K
Applications
Unit Description
WI-BP-I/O-9-K
Dimensions
5.1"
(150 mm)
6.7"
(170 mm)
1.4"
(36 mm)
2.5"
(64 mm)
188
Class I, Division 2
E
xpected Life:1 month to 1 year, depending on usage
and power settings (WI-BP-I/O-9-K will indicate low
battery status)
WI-I/O-9-K
C1D2
US
Technical Data
Inputs:
Digital:
Pulse:
Up/Down Pulse Count
Pulse Rate
Analog:
resolution
accuracy
sample time configurable
transducer warm-up time configurable
analog value transmitted on change of input signal or time elapsed
since last transmission,
change sensitivity configurable
update time configurable
Setpoint Status
Power Supply
Power consumption @12VDC
Power consumption during radio transmission
(50 - 100 msec)
Analog loop supply internally generated
Internal monitoring of supply low voltage status
Power consumption increases for pulse inputs > 10Hz.
General Data
Operating Temperature
Humidity
EMC Standards
Mounting
LED indication
Frequency Hopping Spread Spectrum
Transmit power
Maximum line of sight range
Receiver data sensitivity
Data rate
Antenna connector
Dimensions mm (in)
Approvals
two digital/pulse inputs, suitable for voltage free contacts / NPN, or voltage input 0-1 VDC on / >3 VDC off
status transmission on change of input signal and on time elapsed since last transmission - update time period 10 sec - 5days, a separate update
time can be configured when the discrete input is on
Pulse rate up to 1000 Hz, 3 msec on time. Pulse counted as 16 bit register with a 16 bit overflow register (total count 32 bit). Transmissions occur
when count change exceeds configured increase, or on time elapsed since last transmission; update time 10 sec - 5 days ; change transmissions
may be suspended if increase exceeds a configured value to reduce radio traffic.
the two pulse inputs may be configured to a single count, to suit quadrature or incremental shaft encoder transducers.
calculated from rate of pulse input and treated as an internal analog input. Configurable scaling. Transmitted as per analog input.
one analog input 0-25 mA (4-20mA, 0-10mA)
0-10V also available floating differential input
12 bit
< 0.1 % measurement continuous or sampled
1 min - 5 days
0.5-127 sec
0.7-75%
0.1min - 5 days
high and low setpoints generate internal digital status
setpoint status sets (on) when analog value < low setpoint and resets (off) when analog value > high setpoint
status transmitted as per digital input
6 - 30VDC
quiescent (sleep mode) 120A, operating mode 10mA + analog loop
300mA @ 1W, 220A @ 500mW
100mA @ 100mW, 50mA @ 10mW
Yes
may be transmitted to remote modules as an input
US
Ordering Data
Type
Battery Pack (optional)
Plug and Lead-1 meter (included w/ radio)
WI-I/O-9-K
WI-BP-I/O-9-K
WI-PLI-9-K
Part No.
6720005004
6720005112
6720005113
189
Main benefits:
Applications
Wirelessly connect PLCs on a new machine to an
existing factory automation system
Interface different automation systems in different
sections of a plant
Connect protocol devices into a common
wirelessnetwork
Weidmuller wireless units are used to wirelessly
transmit signals for PLCs or DCS
Wireless gateways connect to popular process control and
automation databuses, and convert signal information to the
proven WIB-net wireless protocol.
Direct I/O
Features
C
onnects to data bus at full bus speed (e.g. 12Mb/s for
Profibus, 100Mb/s for Ethernet)
P
rovides Protocol Conversion (Profibus, Modbus,
Ethernet, DeviceNet)
C
an interconnect master-slave, slave-slave
and master-master
Interconnects different data buses - wireless
protocol conversion
Provides a peer-to-peer wireless network using WIB-net
High security data encryption
Automatic acknowledgment and error-correction
Multiple path routing
E
ight on-board discrete I/O, individually configurable
as input or output
N
etwork configuration is performed with easy-to-use
free software
W
ide range power supply with integral back-up
battery-charging feature
Frequency hopping spread spectrum
902-928 MHz 1W license-free USA/Canada/Mexico
C
onfigurable sub-bands license-free South America,
Australia/NZ, Asia, Europe available on request
Interconnection Flexibility
190
Profibus
Ethernet
Modbus
DF1
Dimensions
6.57"
(167 mm)
7.2"
(183 mm)
Power Supply
2.16"
(55 mm)
2.4"
(60 mm)
5.1"
(130 mm)
General Specifications
Frequency: frequency hopping spread spectrum 902928 MHz, sub-bands configurable
Power: transmit power 1W, approved to FCC Part
15.247, RSS210
Sensitivity: receiver data sensitivity 108 dBm
Max. Range (line-of-sight): USA/Canada, 4W ERP 20+
miles; other countries, 1W ERP, 15+ km depending on
local conditions
Data Rate:19.2 Kb/s with forward-error correction
Antenna Connector: SMA female coaxial
Temperature: -40 to 60C / -40 to 140F
Humidity: 0 - 99% RH
Regulatory Approvals: EMC Compliant EN 301 489,
FCC Part 15
Certifications: Class I, Division 2 (USA, Canada)
Housing: extruded aluminum case 130 x 183 x 60 mm,
5.1 x 7.2 x 2.4 inches, DIN-rail mounting, removable
terminal blocks for ease of module replacement, terminals
suitable for 12 gauge
(2.5 mm2) wire
Radio communications can be configured for
combination of event-reporting (change-of-state),
update time, read/write blocks, and poll response.
Radio message includes system addressing, unit
addressing, error-checking, and configurable security
encryption. Communication control includes message
acknowledgments and up to four re-transmissions.
Peer-to-peer addressing. Messages may be routed
through five intermediate repeater addresses.
Fail-to-transmit and fail-to-receive alarms
are configurable
191
C1D2
WI-GTWY-9-MD1
Modbus (Master & Slave), DF1
WI-GTWY-9-PR1
Profibus DP Slave
US
9 - 30VDC / 12 - 24VAC
Battery charging circuit included for 12V back-up battery, max charge
current regulated to 0.7A
(>12V supply)
Normal current drain
MD1 version 12V 150mA; 24V 90mA
Other version 12V 270mA; 24V 170mA
Add 5mA per active I/O
Add 12V 350mA; 24V 200mA to above
4300 I/O points (analog plus discrete)
9 - 30VDC / 12 - 24VAC
Battery charging circuit included for 12V back-up battery, max charge
current regulated to 0.7A (>12V supply)
Normal current drain
MD1 version 12V 150mA; 24V 90mA
Other version 12V 270mA; 24V 170mA
Add 5mA per active I/O
Register Size
Number of remote WI-GTWY-9 addresses
General Data
16 bit
500
Operating Temperature
Humidity
EMC Standards
Mounting
LED indication
Dimensions mm (in)
Wireless Communications
On-board I/O
Configuration
Diagnostics
Radio Transceiver
Frequency hopping spread spectrum
Transmit power
Receiver data sensitivity
Maximum line-of-sight range
Data rate
Antenna connector
Approvals
US
US
Ordering Data
Type
Accessories: DB9 Male - DB9 Female Serial config. cable
192
WI-GTWY-9-MD1
WI-CSER-905-9
Part No.
6720005020
6720005105
Type
WI-GTWY-9-PR1
WI-CSER-905-9
Part No.
6720005021
6720005105
C1D2
WI-GTWY-9-ET1
Ethernet IP, Modbus TCP,
TCP/IP functions
WI-GTWY-9-PR2
Profibus DP Master
US
9 - 30VDC / 12 - 24VAC
Battery charging circuit included for 12V back-up battery, max charge
current regulated to 0.7A (>12V supply)
Normal current drain
MD1 version 12V 150mA; 24V 90mA
Other version 12V 270mA; 24V 170mA
Add 5mA per active I/O
Add 12V 350mA; 24V 200mA to above
2048 bytes input and 2048 bytes output up to 4300 discrete I/O
points, or up to 1024 analog in / 1024 analog out
16 bit
500
9 - 30VDC / 12 - 24VAC
Battery charging circuit included for 12V back-up battery, max charge
current regulated to 0.7A (>12V supply)
Normal current drain
MD1 version 12V 150mA; 24V 90mA
Other version 12V 270mA; 24V 170mA
Add 5mA per active I/O
Add 12V 350mA; 24V 200mA to above
2048 bytes input and 2048 bytes output up to 4300 discrete I/O
points, or up to 1024 analog in / 1024 analog out
16 bit
500
Operating Temperature
Humidity
EMC Standards
Mounting
LED indication
EN 301 489, FCC Part 15, Approved to FCC Part 15.247, RS210
DIN rail mounting,
for processor OK, radio TX and RX, serial TX and RX,
active status
130 x 183 x 60 (5.1 x 7.2 x 2.4)
Profibus-DP functionality according to EN 50170.
RS-485 optically isolated with on-board DC/DC converter, automatic
baudrate detection
(9600 bit/s - 12 Mbit/s)
Eight discrete I/O, individually configurable as input or output. Inputs
suitable for voltage free contacts.
Outputs are FET, 30VDC 500mA.
via free Windows software
on-line read/write of I/O registers, radio signal strength values from
remote units, and off-line testing of data bus protocol.
EN 301 489, FCC Part 15, Approved to FCC Part 15.247, RS210
DIN rail mounting,
for processor OK, radio TX and RX, serial TX and RX,
active status
130 x 183 x 60 (5.1 x 7.2 x 2.4)
10/100 Mbit/s, RJ45 connector, Transformer isolated interface
Modbus/TCP class 0, class 1 and partially class 2 slave
EtherNet/IP level 2 I/O Server
Embedded Web system (Dynamic HTTP), on-board file system (1.4MB
flash disc), user downloadable web pages through FTP server, Email
functionality (SMTP)
Eight discrete I/O, individually configurable as input or output. Inputs
suitable for voltage free contacts.
Outputs are FET, 30VDC 500mA.
via free Windows software
on-line read/write of I/O registers, radio signal strength values from
remote units, and off-line testing of data bus protocol.
Dimensions mm (in)
Wireless Communications
On-board I/O
Configuration
Diagnostics
Radio Transceiver
Frequency hopping spread spectrum
Transmit power
Receiver data sensitivity
Maximum line-of-sight range
Data rate
Antenna connector
Approvals
US
US
Ordering Data
Type
Accessories: DB9 Male - DB9 Female Serial config. cable
WI-GTWY-9-PR2
WI-CSER-905-9
Part No.
6720005022
6720005105
Type
WI-GTWY-9-ET1
WI-CSER-905-9
Part No.
6720005023
6720005105
193
C1D2
WI-GTWY-9-M+1
Modbus Plus Slave
WI-GTWY-9-DE1
DeviceNet Slave
US
On-board I/O
Configuration
Diagnostics
Radio Transceiver
Frequency hopping spread spectrum
Transmit power
Receiver data sensitivity
Maximum line-of-sight range
Data rate
Antenna connector
Approvals
9 - 30VDC / 12 - 24VAC
Battery charging circuit included for 12V back-up battery, max charge
current regulated to 0.7A
(>12V supply)
Normal current drain
MD1 version 12V 150mA; 24V 90mA
Other version 12V 270mA; 24V 170mA
Add 5mA per active I/O
Add 12V 350mA; 24V 200mA to above
512 bytes input and 512 bytes output up to
4300 discrete I/O points, or up to 256 analog in / 256 analog out
16 bit
500
9 - 30VDC / 12 - 24VAC
Battery charging circuit included for 12V back-up battery, max charge
current regulated to 0.7A
(>12V supply)
Normal current drain
MD1 version 12V 150mA; 24V 90mA
Other version 12V 270mA; 24V 170mA
Add 5mA per active I/O
Add 12V 350mA; 24V 200mA to above
2048 bytes input and 2048 bytes output up to
4300 discrete I/O points, or up to 1024 analog in / 1024 analog out
16 bit
500
0 - 95 %RH
EN 301 489, FCC Part 15, Approved to FCC Part 15.247, RS210
DIN rail mounting,
for processor OK, radio TX and RX, serial TX and RX,
active status
130 x 183 x 60 (5.1 x 7.2 x 2.4)
DeviceNet 2.0 Slave, optically isolated RS422 with selectable baudrate
between 125, 250 and 500 Kbit/sec.
Eight discrete I/O, individually configurable as input or output. Inputs
suitable for voltage free contacts.
Outputs are FET, 30VDC 500mA.
via free Windows software
on-line read/write of I/O registers, radio signal strength values from
remote units, and off-line testing of data bus protocol.
0 - 95 %RH
EN 301 489, FCC Part 15, Approved to FCC Part 15.247, RS210
DIN rail mounting,
for processor OK, radio TX and RX, serial TX and RX,
active status
130 x 183 x 60 (5.1 x 7.2 x 2.4)
Modbus RTU (binary), master / slave configurable. RS232 or RS485,
300 - 19200 bits/sec.
Modbus Plus Slave, optically isolated RS485 with standard baudrate
of 1 Mbit/sec, global data base transactions with routing for up to six
networks.
Eight discrete I/O, individually configurable as input or output. Inputs
suitable for voltage free contacts.
Outputs are FET, 30VDC 500mA.
via free Windows software
on-line read/write of I/O registers, radio signal strength values from
remote units, and off-line testing of data bus protocol.
US
US
Ordering Data
Type
Accessories: DB9 Male - DB9 Female Serial config. cable
194
WI-GTWY-9-DE1
WI-CSER-905-9
Part No.
6720005024
6720005105
Type
WI-GTWY-9-M+1
WI-CSER-905-9
Part No.
6720005025
6720005105
195
6720005054
WI-MOD-E-G
6720005057
WI-MOD-E-A
6720005015
WI-MOD-945-E
1242110000
IE-WL-AP-BR-CL-ABG-US
6720005051
WI-MOD-9-E
Frequency
2.412 - 2.472GHz
5.18 - 5.825GHz1
902-928MHz1
2.4Ghz / 5.8Ghz
902 - 928MHz1
Modulation
802.11b/g + OFDM
802.11a + OFDM
802.11 g + OFDM
802.11 a/b/g
802.11-FHSS
TX Power
15 - 400mW
15 - 400mW
15 - 630mW
15-100mW
100mW - 1W2
Data Rate
108Mbps
108Mbps
54Mbps
54Mbps
200Kbps
WDS (AP-AP)
Yes
Yes
Yes
Yes
No
Self Heal
(Spanning Tree)
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
WPA2 /802.11i
WPA2 /802.11i
WPA2/802.11i
WPA / WPA2/802.1X
MAC / IP Filtering
Yes
Yes
Yes
Yes
Yes
Network Function
AP /Client
Bridge /Router
AP /Client
Bridge /Router
AP /Client
Bridge /Router
AP/Client/Bridge
AP /Client
Bridge /Router
Online Diagnostics
Yes
Yes
Yes
Yes
Yes
Online Conguration
Yes
Yes
Yes
Yes
Yes
1
2
196
WI-MOD-9-D
Radio 900MHz
C1D2
US
Technical Data
Power Supply
Normal current drain
Current when transmitting
Low power mode current drain
Serial Port
Standard data rates
RS232 and RS485
Characters supported
RS232 Connection
RS485 connection
Input and output buffers
General Data
10 - 30 VDC or 10 - 24 VAC
70mA/12VDC or 50mA/24VDC
350mA/12V or 250mA/ 24V
20mA/12VDC or 15mA/24VDC
1200 to 115200 baud.
standard interface connections provided,
each connected to the same serial port.
Serial interfaces are asynchronous
non-return-zero (NRZ) format
7 or 8 data bits, even/odd/no parity, 1 or 2 stop bits
provides full duplex operation as a DCE device with RTS/CTS hardware
handshaking- standard D9 connector
provides half duplex operation for twisted pair
multi-drop networks
2Kbytes
Operating Temperature
Humidity
EMC Standards
Mounting
LED indication
Dimensions mm (in)
Radio Transceiver
Frequency - USA/Canada
Hop Sequence
Transmit Power
Expected line-of-sight range, depending on local conditions
RF Data Transmission Rate
Range may be extended by:
Antenna connection
Data Transmission
Transparent mode:
Controlled mode:
Configuration
Diagnostics
Approvals
US
Ordering Data
Type
WI-MOD-9-D
Part No.
6720005050
197
WI-MOD-9-E
Ethernet 900MHz
WI-MOD-945-E
Ethernet 900MHz
C1D2
US
Technical Data
Description: Ethernet
Embedded Protocols:
Serial
RS232 V.24 DCE
RS485
Discrete I/O
Input
Output
Networking
General Data
Operating Temperature
Humidity
Power Supply
Current consumption
Transmit
Mounting
LED indication
Dimensions mm (in)
Weight
Radio Transceiver
Frequency - USA/Canada
Hop Channel Spacing
Transmit Power
Receiver sensitivity
Data rates
Protocol
Radio range
Antenna connection
Security
Configuration
Diagnostics
Approvals
US
Ordering Data
Type
WI-MOD-9-E
198
Part No.
6720005051
Type
WI-MOD-945-E
Part No.
6720005015
WI-MOD-E-G
Ethernet 2.4GHz
WI-MOD-E-A
Ethernet 5.8GHz
Technical Data
Description: Ethernet
Embedded Protocols:
Serial
RS232 V.24 DCE
RS485
Discrete I/O
Input
Output
Networking
Type
Type
General Data
Operating Temperature
Humidity
Power Supply
Current consumption
Mounting
LED indication
Dimensions mm (in)
Weight
Wireless
Radio Transceiver
Transmit Power
Receiver sensitivity
Radio range
Antenna connection
Security
Configuration
Diagnostics
Approvals
Ordering Data
WI-MOD-E-G
Part No.
6720005054
WI-MOD-E-A
Part No.
6720005057
199
97 mm [3.82 in]
\T
Technical Data
WLAN Interface
Standards
Security
Transmission Rates
TX Transmit Power
RX Sensitivity
Protocol Support
General Protocols:
AP-only Protocols:
200
Interface
IEEE 802.11a/b/g/h for Wireless LAN
IEEE 802.11i for Wireless Security
IEEE 802.3u for 10/100BaseT(X)
IEEE 802.3af for Power-over-Ethernet
IEEE 802.1D for Spanning Tree Protocol
IEEE 802.1w for Rapid STP
IEEE 802.1Q VLAN
DSSS with DBPSK, DQPSK, CCK
OFDM with BPSK, QPSK, 16QAM, 64QAM
802.11b: CCK @ 11/5.5 Mbps,
DQPSK @ 2 Mbps,DBPSK @ 11 Mbps
802.11a/g: 64QAM @ 54/48 Mbps, 16QAM @ 36/24
Mbps, QPSK @ 18/12 Mbps, BPSK @ 9/6 Mbps
US: 2.412 to 2.462 GHz (11 channels)
5.18 to 5.24 GHz (4 channels)
EU: 2.412 to 2.472 GHz (13 channels)
5.18 to 5.24 GHz (4 channels)
SSID broadcast enable/disable
Firewall for MAC/IP/Protocol/Port-based filtering
64-bit and 128-bit WEP encryption,
WPA /WPA2-Personal and Enterprise
(IEEE 802.1X/RADIUS, TKIP and AES)
802.11b: 1, 2, 5.5, 11 Mbps
802.11a/g: 6, 9, 12, 18, 24, 36, 48, 54 Mbps
802.11b: Typ. 231.5 dBm @ 1 to 11 Mbps
802.11g: Typ. 201.5 dBm @ 6 to 24 Mbps,
Typ. 191.5 dBm @ 36 Mbps,
Typ. 181.5 dBm @ 48 Mbps,
Typ. 171.5 dBm @ 54 Mbps
802.11a: Typ. 181.5 dBm @ 6 to 24 Mbps,
Typ. 161.5 dBm @ 36 to 48 Mbps,
Typ. 151.5 dBm @ 54 Mbps
802.11b: -97 dBm @ 1 Mbps, -94 dBm @ 2 Mbps,
-92 dBm @ 5.5 Mbps, -90 dBm @ 11 Mbps
802.11g: -93 dBm @ 6 Mbps, -91 dBm @ 9 Mbps,
-90 dBm @ 12 Mbps, -88 dBm @ 18 Mbps,
-84 dBm @ 24 Mbps, -80 dBm @ 36 Mbps,
-76 dBm @ 48 Mbps, -74 dBm @ 54 Mbps
802.11a: -90 dBm @ 6 Mbps, -89 dBm @ 9 Mbps,
-89 dBm @ 12 Mbps, -85 dBm @ 18 Mbps,
-83 dBm @ 24 Mbps, -79 dBm @ 36 Mbps, -75 dBm @ 48
Mbps, -74 dBm @ 54 Mbps
Proxy ARP, DNS, HTTP, HTTPS, IP, ICMP, SNTP, TCP, UDP,
RADIUS, SNMP, PPPoE, DHCP
ARP, BOOTP, DHCP, dynamic VLAN-Tags for
802.1X-Clients, STP/RSTP (IEEE 802.1D/w)
Default Antenna
Connector for External Antennas
LAN Port
Console Port
LED Indicators
Alarm Contact
Digital Inputs
Physical Characteristics
Housing
Weight
Dimensions
Installation
Environmental Limits
Operating Temperature
Storage Temperature
Ambient Relative Humidity
Power Requirements
Input Voltage
Connector
Power Consumption
Reverse Polarity Protection
Regulatory Approvals
Safety
Radio
EMC
Hazardous Location
MTBF
Warranty
Warranty Period
Ordering Data
Models
Model Type
IE-WL-AP-BR-CL-ABG-EU
IE-WLT-AP-BR-CL-ABG-EU
IE-WL-AP-BR-CL-ABG-US
IE-WLT-AP-BR-CL-ABG-US
Accessories
Model Type
Operating
Temperature
0 to +60 C
-40 to +75 C
0 to +60 C
-40 to +75 C
Part No.
1242100000
1286480000
1242110000
1286490000
Part No.
EBR-Module RS232
1241430000
RM-KIT
1241440000
201
Specialty Enclosures
Enclosures
Specialty Enclosures
At Weidmuller, we have the resources and capabilities
to design and build both industrial and ATEX certified
enclosures. We handle every aspect of the process:
Initial design specifications
Assembly and installation of box elements
Design and specification of DIN-rail modules
Terminal wiring
Specifying, ordering and integrating
third-party products
Application of special coatings
Adding elements such as mounting plates
and holes or knockouts for cable glands
Providing full ATEX certification
and documentation
202
Pre-configured
Wireless Enclosures
Weidmuller is pleased to offer three
pre-configured and assembled Wireless
Enclosure Solutions. These three
wireless enclosures feature plastic or
metal enclosures with either Wireless
Ethernet Modems or Radio Frequency (RF)
Transmitters/Receivers. Just connect power
and your signals and
you are wireless!
Ordering Data
Wireless Ethernet Enclosure Stainless Steel Solution
Dimensions mm/in (h x w x d)
Part No.
6760004616
458 x 382 x 205 / 18.03 x 15.04 x 8.07
Features:
Ordering Data
Wireless Ethernet Enclosure - Plastic Solution
Dimensions mm/in (h x w x d)
Part No.
6760004617
356 x 305 x 212 / 14.02 x 12.01 x 8.35
Features:
NEMA 4X Plastic Enclosure
2.4GHz (WiFi) Wireless Ethernet modem
Operate as a Client/Bridge/Access Point/Router
with a 400mW transmit power
Built in Security/Encryption including AES,
and WEP with matching antenna and all cabling
Assembled, wired, and tested!
Surge protection included
Transmit range up to 3 miles with appropriate antenna
Data transmission rates up to 54Mbps
203
The I/O version is comprised of two preassembled plastic enclosures. Each enclosure
contains a power supply, circuit protection,
surge protection, antenna, antenna connection
cables and terminal blocks.
In addition to these components, one enclosure
houses a transmitter, and the second enclosure
houses a receiver. The transmitter and receiver
operate on 900Mhz radio bands, and are
precongured to send and receive multiple
I/O signals. The I/O solution can transmit and
receive two digital signals and one analog
signal over a range of several miles.
This self-contained solution is designed
for quick and easy set-up. The pre-installed
terminals make I/O and power connections fast
and easy, for out of the box operation.
204
Ordering Data
Wireless I/O 900MHz - Plastic Solution
Dimensions mm/in (h x w x d)
Part No.
6760004618
307 x 256 x 162 / 12.08 x 10.09 x 6.38
Features:
Two pre-assembled NEMA4x Plastic Enclosures and
Full IP67 Ingress protection
900MHz (Frequency Hopping) Transmitter and
Receiver with a 1W transmit power
Preconfigured and mapped I/O
with matching antenna and all cabling
Surge protection included
Cable glands included for signal and power access
Assembled, wired, and tested!
Transmit range up to 20 miles with appropriate antenna
Transmitter accepts up to 1 analog and 2 digital intputs
Receiver accepts up to 1 analog and 2 digital outputs
Selection Guide
Wireless Accessories
Description
Type
Connector Type
-2 dBd
-2 dBd
0 dBd
0 dBd
3 dBd
3 dBd
Direct attach
Mount Bkt & 3ft cable
Direct attach
Mount Bkt & 15ft cable
Only use with MAG Base 6720005263
Only use with thru-panel base 6720005277
SMA male
SMA male
SMA male
SMA male
Determined by MAGBASE
Determined by Base (N Female)
Part No.
6720005232
6720005086
6720005089
6720005080
6720005230
6720005276
Omni
Gain
Description
Type
Connector Type
0 dBd
3 dBd
5 dBd
7 dBd
WI-ANT-900MHZ-0DB OMNI NF
WI-ANT-900MHZ-3DB OMNI NF
WI-ANT-900MHZ-5DB OMNI NF
WI-ANT-900MHZ-7DB OMNI NF
N female
N female
N female
N female
Part No.
6720005233
6720005234
6720005235
6720005236
Directional
Gain
Description
Type
Connector Type
3 dBd
6.5 dBd
10 dBd
12 dBd
14 dBd
Inc.6720005266 clamp/brkt
Inc.6720005266 clamp/brkt
Inc.6720005266 clamp/brkt
Inc.6720005266 clamp/brkt
Inc.6720005267 clamp/brkt
WI-ANT-900MHZ-3DB YAGI NF
WI-ANT-900MHZ-6.5DB-2YAGI NF
WI-ANT-900MHZ-10DB-2YAGI NF
WI-ANT-900MHZ-12DB-2YAGI NF
WI-ANT-900MHZ-14DB-2YAGI NF
N female
N female
N female
N female
N female
Part No.
6720005219
6720005221
6720005223
6720005225
6720005226
Whip
Gain
Description
Type
Connector Type
0 dBi
2 dBi
3 dBi
4 dBd
Direct attach
Direct attach
Use with MAG base 6720005263
Only use with thru-panel base 6720005277
WI-ANT-DEMO-2400
WI-ANT-24GHZ-2DB DUCK SMA-M
WI-ANT-24GHZ-3DB FOR MAG BASE
WI-ANT-0.9/2.4GHZ-3/4DB MOBILE
SMA male
SMA male
N female
Determined by Base (N Female)
Part No.
6720005099
6720005207
6720005208
6720005276
Omni
Gain
Description
Type
Connector Type
4 dBi
6 dBi
8 dBi
10 dBi
12 dBi
WI-ANT-24GHZ-4DB OMNI NF
WI-ANT-24GHZ-6DB OMNI NF
WI-ANT-24GHZ-8DB OMNI NF
WI-ANT-24GHZ-10DB OMNI NF
WI-ANT-24GHZ-12DB OMNI NF
N female
N female
N female
N female
N female
Part No.
6720005200
6720005201
6720005204
6720005202
6720005203
Directional
Gain
Description
Type
Connector Type
9 dBi (60)
10 dBi
13 dBi (35)
14 dBi
18 dBi (18)
N female
N female
N female
N female
N female
Part No.
6720005212
6720005205
6720005213
6720005206
6720005214
205
Selection Guide
Whip
Gain
Description
Type
Connector Type
4dBi
WI-ANT-5.8GHZ-4DB MOBILE
Part No.
6720005278
Omni
Gain
Description
Type
Connector Type
7dBi
WI-ANT-5.8GHZ-7DB OMNI NF
6720005283
Part No.
10dBi
WI-ANT-5.8GHZ-10DB OMNI NF
6720005284
Directional
Gain
Description
Type
Connector Type
8dB / 9dB
Part No.
6720005280
11dBi
6720005130
13dBi
6720005281
18dB / 20dB
6720005282
WLAN Accessories
Antennas
Gain
Description
Type
Connector Type
5dBi
Omni Antenna
IE-ANT-O-AH-360-5-NF
N - Type Female
1367120000
Part No.
6dBi
Omni Antenna
IE-ANT-O-BG-360-6-NF
N - Type Female
1367090000
7dBi
Omni Antenna
IE-ANT-O-ABG-360-7-NF
N - Type Female
1367130000
9dBi
Parabolic Antenna
IE-ANT-P-ABG-75-9-NF
N - Type Female
1367140000
Length
Description
Type
Connector Type
2M
Cable
IE-CC-NM-RPSMAM-2M
RP-SMA to N male
1367110000
4M
Cable
IE-CC-NM-RPSMAM-4M
RP-SMA to N male
1367100000
Cables
206
Part No.
Selection Guide
Cables
Connector Type
SMA male - SMA male
SMA male - SMA male
SMA male - SMA male
SMA male - N male
SMA male - N male
SMA male - N male
SMA male - N male
SMA male - N male
SMA male - N male
N male - N male
N male - N male
N male - N male
N male - N male
N male - N male
N male - N male
N male - N male
N male - N male
N male - N male
N male - N male
dB Loss 900Mhz
0.1
0.2
0.3
0.1
0.2
0.4
1.2
2.8
4.5
0.1
0.2
0.3
0.4
1.0
1.6
2.1
3.0
3.8
5.0
dB Loss 2.4GHz
0.2
0.4
0.6
0.2
0.4
0.6
2.0
4.8
7.7
0.2
0.4
0.6
0.7
1.7
2.7
3.7
5.2
6.7
9.6
dB Loss 5.8GHz
0.3
0.7
1.0
0.3
0.7
1.0
3.4
8.2
13.1
0.2
0.4
0.6
1.1
2.7
4.3
5.9
8.1
10.8
N/A
Cable Type
PFP 195
PFP 195
PFP 195
PFP 195
PFP 195
PFP 195
PFP 400
PFP 400
PFP 400
PFP 400
PFP 400
PFP 400
PFP 400
PFP 400
PFP 400
PFP 400
PFP 400
PFP 400
PFP 600
Type
WI-ACC-TYP195-1FT SMA M-SMA M
WI-ACC-TYP195-2FT SMA M-SMA M
WI-ACC-TYP195-3FT SMA M-SMA M
WI-ACC-TYP195-1FT SMA M-NM
WI-ACC-TYP195-2FT SMA M-NM
WI-ACC-TYP195-3FT SMA M-NM
WI-ACC-TYP400-10FT SMA M-NM
WI-ACC-TYP400-25FT SMA M-NM
WI-ACC-TYP400-40FT SMA M-NM
WI-ACC-TYP195-1FT NM-NM
WI-ACC-TYP195-2FT NM-NM
WI-ACC-TYP195-3FT NM-NM
WI-ACC-TYP400-10FT NM-NM
WI-ACC-TYP400-25FT NM-NM
WI-ACC-TYP400-40FT NM-NM
WI-ACC-TYP400-55FT NM-NM
WI-ACC-TYP400-75FT NM-NM
WI-ACC-TYP400-100FT NM-NM
WI-ACC-TYP600-200FT NM-NM
Part No.
6720005243
6720005244
6720005245
6720005270
6720005260
6720005259
6720005240
6720005241
6720005242
6720005246
6720005247
6720005248
6720005251
6720005252
6720005253
6720005254
6720005255
6720005256
6720005257
Hardware
Description
For use with
DB9 Female RJ45 Serial Configuration Cable
WI-I/O 9-L units
Antenna Mounting Brackets
Angled Bracket for 4, 6, and 10 dBi 2.4 MHz Omnis
2.4 GHz antennas
Straight Bracket for 4, 6, and 10 dBi 2.4 MHz Omnis
2.4 GHz antennas
2.4 GHz antennas
Mounting Bracket for part number 6720005203
Antenna MAG Base with 12 SMA male cable
2.4 GHz & 900 MHz antennas
900 MHz antennas
Mounting Bracket for parts 6720005228 and 6720005229
Mounting Bracket for 900MHz 6.5, 10, 12 dBd Yagis
900 MHz antennas
900 MHz antennas
Mounting Bracket for part number 6720005226
Mounting Bracket for part numbers 6720005233,
900 MHz antennas
6720005234, 6720005235
Mounting Bracket for part number 6720005236
900 MHz antennas
Thru-panel mounting base for low profile antennas
6720005276 & 6720005278
Surge Protection & Bulkhead Mounts
125-1000 MHz Surge Polyphaser N female - N female
Bulkhead & Surge 1 GHz
2-6 GHz Surge Polyphaser N female - N female
Bulkhead & Surge 2 GHz
Bulkhead Adapter N female -N female
Bulkhead WI-ACC-BULK-ADAPT NF-NF
Bulkhead Adapter SMA female - SMA female
Bulkhead WI-ACC-BULK SMA F - SMA F
Class 1 Division 1 Bulkhead SMA male - SMA female
Bulkhead WI-ACC-BULK-C1D1 SMA M - SMA M
Class 1 Division 1 Bulkhead SMA male - N male
Bulkhead WI-ACC-BULK-C1D1 SMA M - NM
SMA male to SMA female <2.5Ghz (direct radio connection)
2.4 GHz & 900 MHz antennas
Bandpass Filters
900 MHz antennas
Outdoor rated 900Mhz Band Pass Filter
Outdoor rated 2.4Ghz Band Pass Filter
2.4 GHz antennas
Outdoor rated 5.8Ghz Band Pass Filter
5.8 GHz antennas
Type
WI-CSER-RJ45
Part No.
6720005108
WI-ACC-24GHZ-4610DB-ANG-BRKT
WI-ACC-24GHZ-4610DB-STR-BRKT
WI-ACC-24GHZ-12DB-STR-BRKT
WI-ACC-MAGBASE 12 RG58 SMA MALE
WI-ACC-900MHZ-OMNI-STR-BRKT
WI-ACC-900MHZ-YAGI-STR-BRKT
WI-ACC-900MHZ-14YAGI-STR-BRKT
6720005209
6720005210
6720005211
6720005263
6720005268
6720005266
6720005267
WI-ACC-900MHZ-035OMNI-STR-BRKT
WI-ACC-900MHZ-7OMNI-STR-BRKT
WI-ACC-BH-BASE 5/8 HOLE NF
6720005271
6720005272
6720005277
6720005261
6720005262
6720005250
6720005296
6720005298
6720005299
6720005111
6720005120
6720005121
6720005122
Adapters
Description
Reverse-Polarity SMA Male SMA Female
SMA male - SMA male Adapter
SMA female - SMA female Adapter
N male - N male Adapter
N female - N female Adapter
SMA female - N male Adapter
SMA male - N female Adapter
SMA female - SMA male Angled Adapter
Type
WI-ACC-ADAPT RP-SMA M - SMA F
WI-ACC-ADAPT SMA M - SMA M
WI-ACC-ADAPT SMA F - SMA F
WI-ACC-ADAPT NM - NM
WI-ACC-ADAPT NF - NF
WI-ACC-ADAPT SMA F - NM
WI-ACC-ADAPT SMA M - NF
WI-ACC-ADAPT SMA F - SMA M ANGL
Part No.
6720005289
6720005290
6720005291
6720005292
6720005293
6720005294
6720005295
6720005297
207
Antennas
WI-ANT-5.8GHZ-7DB
OMNI NF
WI-ANT-5.8GHZ-4DB MOBILE
WI-ANT-5.8GHZ-10DB
OMNI NF
Technical Data
Maximum Power
Polarization
Nominal Impedance
VSWR across the band
Radome Material
Termination
Mounting Base Diameter
Electrical Specifications
150 Watts
Vertical
50 Ohms
< 1.5:1
PVC
Determined by thru-panel base
Compatible with most 1-1/8" - 18 thread
mounts, including 3/4" hole mounts
25 watts
Vertical Linear
50 Ohms
< 2.0
PVC
N Female
1-5/16"
25 watts
Vertical Linear
50 Ohms
< 2.0
PVC
N Female
1-5/16"
Frequency Range
Gain
Half Power
Vertical Beamwidth
Mechanical Specifications
4.9-5.9 GHz
4dBi
5.15-5.875 GhHz
7dBi
5.15-5.875 GhHz
10dBi
15
10
Antenna Type
Connector Type
Antenna Height
Bending Moment at
Rated Wind
Max wind load @
rated velocity
Equivalent Flat Plate Area
Rated Wind
Weight lbs (kg)
Temperature Range
Omni
N Female
10.2"
Omni
N Female
18.38"
1.1 ft-lbs
5.6 ft-lbs
1.5" OD
0.34 (0.15)
-40 to +70C
3.1 lbs
0.04ft2
125 mph
6.8 lbs
0.08ft2
125 mph
0.3 (0.14)
-40 to +70C
0.35 (0.16)
-40 to +70C
Ordering Data
208
Type
WI-ANT-5.8GHZ-4DB MOBILE
Part No.
6720005278
Type
WI-ANT-5.8GHZ-7DB OMNI NF
Part No.
6720005283
Type
WI-ANT-5.8GHZ-10DB OMNI NF
Part No.
6720005284
WI-ANT-5.8GHZ-13DB DFP
2'NF
WI-ANT-5.8GHZ-20DB DFP
2'NF
Technical Data
Maximum Power
Polarization
Nominal Impedance
VSWR across the band
Radome Material
Termination
Mounting Method
Electrical Specifications
Frequency Range
Gain
Half Power
Vertical Beamwidth
Half Power
Horizontal Beamwidth
Front to Back Ratio
Mechanical Specifications
Antenna Type
Connector Type
Dimensions
Max Wind Load @
Rated Velocity
Equivalent Flat Plate Area
Rated Wind
Weight lbs (kg)
Temperature Range
25 watts
Linear, Vertical/horizontal
50 Ohms
< 2.0:1
UL 94-V0 Plastic
N Female
adjustable
25 watts
Linear, Vertical/horizontal
50 Ohms
< 1.5:1
UL 94HB Polymer
SMA-Female
Four 1/4" Holes
25 watts
Linear, Vertical/horizontal
50 Ohms
< 1.5:1
UL 94-V0 Plastic
N Female
adjustable
25 watts
Linear, Vertical/horizontal
50 Ohms
< 2.0:1
UL 94-V0 Plastic
N Female
Indoor/Outdoor articulating;
heavy duty adjustable
4.9-5.9 GHz
13 dBi
27
60
30
40
21 (9)
>15 dB (>22dB)
>25 dB
> 25 dB
>25 dB (>30dB)
Directional Panel
N Female
5.1" x 4.7" x 1.5"
Directional Panel
SMA-Female
4.5" x 4.5" x 1"
Directional Panel
N Female
5.1" x 4.7" x 1.5"
Directional Panel
N Female
15.1" x13.9" x 1.9"
9.3 lbs
125 mph
0.5 (0.23)
-40 to +70C
>150 mph
<0.4 (<0.2)
-40 to +85C
9.3 lbs
85 lbs
125 mph
0.5 (0.23)
-40 to +70C
125 mph
3.9 (1.8)
-40 to +70C
Ordering Data
Type
WI-ANT-5.8GHZ-9DB 6720005280
WI-ANT 5.8GHZ 11DB 6720005130
DFP 2'NF
FLAT PATCH
Part No.
Type
Part No.
Type
Part No.
WI-ANT-5.8GHZ-13DB 6720005281
DFP 2'NF
Type
Part No.
WI-ANT-5.8GHZ-20DB 6720005282
DFP 2'NF
209
WI-ANT-DEMO-2400
WI-ANT-24GHZ-2DB
DUCK SMA-M
WI-ANT-24GHZ-3DB
FOR MAG BASE
Technical Data
Maximum Power
Polarization
Nominal Impedance
VSWR across the band
Radome Material
Termination
Mounting Base Diameter
Electrical Specifications
1 watt
Vertical
50 ohms
1.5:1
Polyurethane
N female
N/A
50 watts
Vertical, Linear
50 ohms
< 1.5:1
Polyurethane
N female
N/A
200/150/100 watts
Vertical
50 ohms
< 1.5:1
Stainless steel
N female
N/A
Frequency Range
Gain
Half Power
Vertical Beamwidth
Mechanical Specifications
2.4 GHz
0dB
2.4 GHz
2 dBi
N/A
50
30
Antenna Type
Connector Type
Antenna Height
Bending Moment at
Rated Wind
Max Wind Load @
Rated Velocity
Equivalent Flat Plate Area
Rated Wind
Weight lbs (kg)
Temperature Range
Whip
SMA male
54 mm
Whip
SMA male
114.3 mm
N/A
N/A
N/A
N/A
N/A
N/A
0.019 (0.009)
N/A
N/A
N/A
N/A
0.15 (0.068)
-40C to +85C
N/A
N/A
N/A
0.25 (0.113)
-40C to +70C
Ordering Data
Type
Part No.
Type
WI-ANT-DEMO-2400
6720005099
WI-ANT-24GHZ-2DB
DUCK SMA-M
210
Part No.
6720005207
Type
WI-ANT-24GHZ-3DB
FOR MAG BASE
Part No.
6720005208
WI-ANT-24GHZ-4DB
OMNI NF
Technical Data
Maximum Power
Polarization
WI-ANT-0.9/2.4GHZ-3/4DB
MOBILE
WI-ANT-24GHZ-6DB
OMNI NF
Representative Photo
25 watts
Vertical
100 watts
Vertical
25 watts
Vertical
Nominal Impedance
50 ohms
50 ohms
50 ohms
< 1.5:1
UV resistant pultruded fiberglass
< 2.0:1
PVC
< 1.5:1
UV resistant pultruded fiberglass
Termination
Mounting Base Diameter
N female
1.25"
N female
1.25"
Omni
N female
8.1" (205.7 mm)
0.7 ft-lbs
2.1 lbs
.02 ft2
125 mph
0.34 (0.154)
-40C to +70C
Omni
N female
11.6" (294.6 mm)
1.4 ft-lbs
3.0 lbs
.04 ft2
125 mph
0.38 (0.172)
-40C to +70C
Electrical Specifications
Frequency Range
Gain
Half Power Vertical Beamwidth
Mechanical Specifications
Antenna Type
Connector Type
Antenna Height
Bending Moment at Rated Wind
Max wind load @ rated velocity
Equivalent Flat Plate Area
Rated Wind
Weight lbs (kg)
Temperature Range
Ordering Data
Type
WI-ANT-24GHZ-
4DB OMNI NF
1.5" OD
0.29 (0.13)
-40C to +70C
Part No.
6720005200
Type
WI-ANT-0.9/ 2.4GHZ-3/4DB
MOBILE
Part No.
6720005276
Type
WI-ANT-24GHZ-6DB OMNI NF
Part No.
6720005201
211
WI-ANT-24GHZ-8DB
OMNI NF
WI-ANT-24GHZ-10DB
OMNI NF
WI-ANT-24GHZ-12DB
OMNI NF
Technical Data
Maximum Power
Polarization
Nominal Impedance
VSWR across the band
Radome Material
Termination
Mounting Base Diameter
Electrical Specifications
Frequency Range
Gain
Half Power Vertical Beamwidth
Mechanical Specifications
Antenna Type
Connector Type
Antenna Height
Bending Moment at Rated Wind
Max Wind Load @ Rated Velocity
Equivalent Flat Plate Area
Rated Wind
Weight lbs (kg)
Temperature Range
25 watts
Vertical
50 ohms
< 1.5:1
UV resistant pultruded fiberglass
N female
1.25"
25 watts
Vertical
50 ohms
< 1.5:1
UV resistant pultruded fiberglass
N female
1.25"
25 watts
Omni
N female
20.2" (513.1 mm)
4.4 ft-lbs
5.2 lbs
.06 ft2
125 mph
0.50 (0.226)
-40C to +70C
Omni
N female
36.0" (914.4 mm)
14.7 ft-lbs
10.1 lbs
.11 ft2
125 mph
0.65 (0.295)
-40C to +70C
Omni
N female
44.0" (1118 mm)
41 ft-lbs
22.4 lbs
.25 ft2
125 mph
3.00 (1.400)
-40C to +70C
Vertical
50 ohms
< 1.5:1
UV resistant pultruded fiberglass
N female
1.5"
Ordering Data
212
Type
WI-ANT-24GHZ-8DB
OMNI NF
Part No.
6720005204
Type
WI-ANT-24GHZ-10DB
OMNI NF
Part No.
6720005202
Type
WI-ANT-24GHZ-12DB
OMNI NF
Part No.
6720005203
WI-ANT-24GHZ-10DB
YAGI NF
WI-ANT-24GHZ-9DB
DFP 2 NF
WI-ANT-24GHZ-13DB
DFP 2 NF
Technical Data
Maximum Power
Polarization
Nominal Impedance
VSWR across the band
Radome Material
Cable Length and type
Termination
Mounting Method
Electrical Specifications
Frequency Range
Gain
Half Power
Horizontal Beamwidth
Half Power
Vertical Beamwidth
Front to Back Ratio
Mechanical Specifications
Antenna Type
Connector Type
Dimensions
Max Wind Load
@ Rated Velocity
Equivalent Flat Plate Area
Rated Wind
Weight lbs (kg)
Temperature Range
20 watts
linear
50 ohms
<1.6: 1
UV stable plastic
12" RG58/U
N female
Indoor/outdoor articulating; heavy duty
outdoor adjustable
5 watts
linear
50 ohms
<1.5: 1
UV stable plastic
36" coax
N female
heavy duty outdoor
adjustable
20 watts
linear
50 ohms
<1.6: 1
UV stable plastic
12" RG58/U
N female
Indoor/outdoor articulating; heavy duty
outdoor adjustable
60
55
35
60
>15 dB
55
>23 dB
35
>18 dB
Directional Panel
N female
5.1"x4.7"x1.5"
Directional Yagi
N female
4.5" x 3"
Directional Panel
N female
8.8"x8.1"x1.6"
9.3 lbf
125 mph
0.5 (0.227)
-40C to +70C
5.8 lbf
0.060 ft2
125 mph
1.0 (0.5)
-40C to +70C
27.9 lbf
125 mph
1.2 (0.544)
-40C to +70C
Ordering Data
Type
WI-ANT-24GHZ-9DB
DFP 2 NF
Part No.
6720005212
Type
Part No.
Type
WI-ANT-24GHZ-10DB
6720005205
WI-ANT-24GHZ-13DB
YAGI NF
DFP 2 NF
Part No.
6720005213
213
WI-ANT-24GHZ-14DB
YAGI NF
WI-ANT-24GHZ-18DB
DFP 2 NF
Technical Data
Maximum Power
Polarization
Nominal Impedance
VSWR across the band
Radome Material
Cable Length and type
Termination
Mounting Method
Electrical Specifications
Frequency Range
Gain
Half Power
Horizontal Beamwidth
Half Power
Vertical Beamwidth
Front to Back Ratio
Mechanical Specifications
Antenna Type
Connector Type
Dimensions
Max wind load
@ rated velocity
Equivalent Flat Plate Area
Rated Wind
Weight lbs (kg)
Temperature Range
5 watts
linear
50 ohms
<1.5: 1
UV stable plastic
36" coax
N female
Heavy duty outdoor adjustable
20 watts
linear
50 ohms
<1.6: 1
UV stable plastic
12" RG58/U
N female
Indoor/outdoor articulating; heavy duty
outdoor adjustable
30
18
30
>30 dB
19
>25 dB
Directional Yagi
N female
14" x 3"
18.3 lbf
Directional Panel
N female
15.1"x13.9"x1.9"
85 lbf
0.20 ft2
125 mph
1.0 (0.5)
-40C to +70C
125 mph
3.9 (1.77)
-40C to +70C
Ordering Data
214
Type
WI-ANT-24GHZ-14DB
6720005206
YAGI NF
Part No.
Type
WI-ANT-24GHZ-18DB
DFP 2 NF
Part No.
6720005214
WI-ANT-900MHZ-0DB
DUCK SMA M
WI-ANT-DPL-DG900-1
WI-ANT-DEMO-900
Technical Data
Maximum Power
Polarization
Nominal Impedance
VSWR across the band
Radome Material
Termination
Mounting Base Diameter
Electrical Specifications
Frequency Range
Gain
Half Power
Vertical Beamwidth
Mechanical Specifications
Antenna Type
Connector Type
Antenna Height
Bending Moment
at Rated Wind
Max Wind Load
@ Rated Velocity
Equivalent Flat Plate Area
Rated Wind
Weight lbs (kg)
Temperature Range
5 watts
vertical, linear
50 ohms
<2.0:1
50 ohms
50 ohms
SMA male
SMA male
SMA male
900-930 MHz
-2 dBi
900-930 MHz
0 dBi
Portable whip
SMA male
6.5" (16.5 cm)
-40C to +85C
Ordering Data
Type
Part No.
Type
Part No.
Type
WI-ANT-900MHZ-0DB
6720005232
WI-ANT-DPL-DG900-1
6720005086
WI-ANT-DEMO-900
DUCK SMA M
Part No.
6720005089
215
WI-ANT-DPL-0-16
WI-ANT-0.9/2.
4GHZ-3/4DB MOBILE
WI-ANT-900MHZ-0DB
OMNI NF
Representative Photo
Technical Data
Maximum Power
Polarization
Nominal Impedance
VSWR across the band
Radome Material
Termination
Mounting Base Diameter
Electrical Specifications
Frequency Range
Gain
Half Power
Vertical Beamwidth
Mechanical Specifications
Antenna Type
Connector Type
Antenna Height
Bending Moment at
Rated Wind
Max Wind Load @
Rated Velocity
Equivalent Flat Plate Area
Rated Wind
Weight lbs (kg)
Temperature Range
10 watts
vertical
50 ohms
<1.5: 1
Fiberglass
SMA male
100 watts
vertical
50 ohms
<1.5:1
Stainless Steel
Determined by MAGBASE
Determined by MAGBASE
100 watts
vertical
50 ohms
< 2.0:1
PVC
Determined by thru-panel base
Compatible with most 1-1/8" -
18 thread mounts, including 3/4"
hole mounts
150 watts
vertical
50 ohms
853-930 MHz
0 dBi
896-940 MHz
3 dB
902-928 MHz
Unity
75
Omni
N female
14" (35.6 cm)
1.4 ft-lbs
Fiberglass
N female
1-5/16"
2.3 lbs
1.5" OD
0.5 (0.2)
0.06 ft2
100 mph
0.75 (0.34)
-40C to +70C
0.29 (0.13)
-40C to +70C
-40C to +70C
Ordering Data
Type
WI-ANT-DPL-0-16
216
Part No.
6720005080
Type
Part No.
WI-ANT-900MHZ-3DB 6720005230
STUBMAG
Type
WI-ANT-0.9/2.4GHZ3/4DB MOBILE
Part No.
6720005276
Type
WI-ANT-900MHZ-
0DB OMNI NF
Part No.
6720005233
WI-ANT-900MHZ-3DB
OMNI NF
WI-ANT-900MHZ-5DB
OMNI NF
WI-ANT-900MHZ-7DB
OMNI NF
150 watts
vertical
50 ohms
Fiberglass
N female
1-5/16"
150 watts
vertical
50 ohms
Fiberglass
N female
1-5/16"
150 watts
vertical
50 ohms
Technical Data
Maximum Power
Polarization
Nominal Impedance
VSWR across the band
Radome Material
Termination
Mounting Base Diameter
Electrical Specifications
Frequency Range
Gain
Half Power
Vertical Beamwidth
Mechanical Specifications
Antenna Type
Connector Type
Antenna Height
Bending Moment
at Rated Wind
Max Wind Load
@ Rated Velocity
Equivalent Flat Plate Area
Rated Wind
Weight lbs (kg)
Temperature Range
3 dB
902-928 MHz
5 dB
Fiberglass
N female
1-5/16"
902-928 MHz
40
22
902-928 MHz
7 dB
17
Omni
N female
23.25" (59.1 cm)
Omni
N female
48" (121.9 cm)
Omni
N female
96" (243.8 cm)
4.7 ft-lbs
14.2 ft-lbs
62.5 ft-lbs
4.3 lbs
2
0.12 ft
100 mph
1.25 (0.57)
-40C to +70C
8.0 lbs
2
0.22 ft
100 mph
1.75 (0.79)
-40C to +70C
15.8 lbs
2
0.44 ft
100 mph
4 (1.81)
-40C to +70C
Ordering Data
Type
WI-ANT-900MHZ-3DB
6720005234
OMNI NF
Part No.
Type
Part No.
Type
WI-ANT-900MHZ-5DB
6720005235
WI-ANT-900MHZ-7DB
OMNI NF
OMNI NF
Part No.
6720005236
217
WI-ANT-900MHZ-3DB
YAGI NF
WI-ANT-900MHZ6.5DB-2 YAGI NF
WI-ANT-900MHZ10DB-2 YAGI NF
Representative Photo
Technical Data
Maximum Power
Polarization
Nominal Impedance
VSWR Across the band
Radome Material
Termination
Mounting Method
Electrical Specifications
Frequency Range
Gain
Half Power
Horizontal Beamwidth
Half Power
Vertical Beamwidth
Front to Back Ratio
Mechanical Specifications
Antenna Type
Antenna Dimensions (L x W)
Weight lbs (kg)
Cross Sectional Area
Max Wind Load
@ Rated Velocity
Rated Wind
Elements
Cable Type
Cable Length
Connector Type
Temperature Range
200 watts
Linear
50 ohms
<1.5:1
Aluminum 6061-T6
N female
Includes mounting
hardware
200 watts
Linear
50 ohms
<1.5:1
Aluminum 6061-T6
N female
Includes mounting
hardware
890-960 MHz
3 dBd
890-960 MHz
6.5 dBd
200 watts
Linear
50 ohms
<1.5:1
Aluminum 6061-T6
N female
Includes mounting
hardware
890-960 MHz
10 dBd
168
100
56
78
>10 dB
62
>15 dB
46
>20 dB
13" x 6.8"
1.3 (0.59)
2
0.11 ft
Directional Yagi
13" x 6.8"
2 (0.9)
2
0.12 ft
2.75 lbf
125 mph
2
LMR400
2 ft.
N female
-40C to +85C
Directional Yagi
Directional Yagi
3 lbf
125 mph
3
RG213
2 ft.
N female
-40C to +70C
24" x 6.8"
6.8 (3.08)
2
0.24 ft
6 lbf
125 mph
7
RG213
2 ft.
N female
-40C to +70C
Ordering Data
218
Type
WI-ANT-900MHZ-3DB
YAGI NF
Part No.
6720005219
Type
Part No.
WI-ANT-900MHZ-6.5DB-2
6720005221
YAGI NF
Type
WI-ANT-900MHZ-10DB-2
YAGI NF
Part No.
6720005223
WI-ANT-900MHZ14DB-2 YAGI NF
WI-ANT-900MHZ12DB-2 YAGI NF
Representative Photo
Representative Photo
Technical Data
Maximum Power
Polarization
Nominal Impedance
VSWR Across the band
Radome Material
Termination
Mounting Method
Electrical Specifications
200 watts
Linear
50 ohms
<1.5:1
Aluminum 6061-T6
N female
Includes mounting
hardware
200 watts
Linear
50 ohms
<1.5:1
Aluminum 6061-T6
N female
Includes mounting
hardwar
Frequency Range
Gain
Half Power
Horizontal Beamwidth
Half Power
Vertical Beamwidth
Front to Back Ratio
Mechanical Specifications
890-960 MHz
12 dBd
40
890-960 MHz
14 dBd
32
34
26
>20 dB
>25 dB
Antenna Type
Antenna Dimensions (L x W)
Weight lbs (kg)
Cross Sectional Area
Max wind load @ rated velocity
Rated Wind
Elements
Cable Type
Cable Length
Connector Type
Temperature Range
Directional Yagi
37" x 6.6"
2.5 (1.3)
0.35 ft2
8.75 lbf
125 mph
11
RG213
2 ft.
N female
-40C to +70C
Directional Yagi
63" x 6.6"
3.5 (1.58)
0.67 ft2
16.75 lbf
125 mph
18
RG213
2 ft.
N female
-40C to +70C
Ordering Data
Type
WI-ANT-900MHZ-12DB-2
YAGI NF
Part No.
6720005225
Type
WI-ANT-900MHZ-14DB-2
YAGI NF
Part No.
6720005226
219
Cables
Cables
PFP195
PFP400
PFP600
Impedance: 50 ohms
Foamed Polyethylene
100% Bonded Aluminum Foil
Tinned Copper
Braid - CuSn
Flame-retardant PVC
Polyethylene Jacket
Electrical Specifications
41 GHz
80%
1.56
1.27 (4.17)
50 ohms
79.7
0.064 (0.21)
>90 dB
16.2 GHz
85%
1.38
1.20 (3.92)
50 ohms
78.4
0.060 (0.20)
>90 dB
10.3 GHz
87%
1.32
1.17 (3.83)
50 Ohms
76.8
0.058 (0.19)
>90 dB
7.6 (24.9)
4.9 (16.1)
1000 VDC
3000 Vrms
2.5 kW
1.39 (4.6)
1.65 (5.4)
2500 VDC
8000 Vrms
16 kW
0.53 (1.7)
1.2 (3.9)
4000 VDC
8000 Vrms
40 kW
0.5 (12.7)
2.0 (50.8)
0.2 (0.27)
0.021 (0.03)
40 (18.2)
15 (0.27)
0.94 Solid BC
2.8
Bonded Aluminum Foil
0.11 x 112 CuSn
4.95
1.00 (25.4)
4.0 (101.6)
0.5 (0.68)
0.068 (0.10)
160 (72.6)
40 (0.71)
2.74 Solid CCA
7.24
Bonded Aluminum Foil
0.15 x 192 CuSn
10.29
1.50 (38.1)
6.0 (152.4)
2.75 (3.73)
0.131 (0.20)
350 (158.9)
60 (1.07)
4.47 Solid CCA
11.56
Bonded Aluminum Foil
0.18 x 240 CuSn
14.99
Cutoff Frequency
Velocity of Propagation
Dielectric Constant
Time Delay nS/ft (nS/m)
Impedance
Capacitance (pF/m)
Inductance uH/ft (uH/m)
Shielding Effectiveness
DC Resistance:
Inner Conductor ohms/ 1000ft (/km)
Outer Conductor ohms/ 1000ft (/km)
Voltage Withstand
Jacket Spark
Peak Power
Mechanical Specifications
220
WLAN Antennas
WLAN
Antennas
IE-ANT-O-BG-360-6-NF
IE-ANT-O-AH-360-5-NF
Omnidirectional
50 Ohm
Vertical
1 x N-Type female
Bottom
25 W
Omnidirectional
50 Ohm
Vertical
1 x N-Type female
Bottom
6W
outdoor
-40C to 80C
-40C to 80C
IP67
outdoor
-45C to 70C
-45C to 70C
IP64
Technical Data
Electrical Data
Frequency (Mhz)
VSWR
Gain
3dB beamwidth (horizontal)
3dB beamwidth (vertical)
Front to back ratio
Vertical electrical tilt
General Data
Radiation
Nominal Impedance
Polarisation
Connector type
Connector position
Composite power max.
Mechanical Data
Dimensions
Weight
Wind load
Mast Diameter min.
Mast Diameter max.
Environmental Limits
Environmental Conditions
Operating Temperature
Storage Temperature
IP Rating
Material Data
Radom Color
Radom Material
Back plate/base plate material
Ordering Data
Model
802.11 b/g Wireless Antenna;
Omni-directonal
802.11 a/h Wireless Antenna;
Omni-directonal
Note:
Type
Part No.
1367090000
IE-ANT-O-BG-360-6-NF
1367120000
IE-ANT-O-AH-360-5-NF
Mounting material included
221
WLAN Antennas
IE-ANT-P-ABG-75-9-NF
IE-ANT-O-ABG-360-7-NF
Technical Data
Electrical Data
Frequency (Mhz)
VSWR
<2
Gain
75 Band 1 ; 55 Band 2
55 Band 1/2
15 dB Band 1/2
0 Band 1/2
Directional
50 Ohm
Vertical
1 x N-Type female
Bottom
10 W
Omnidirectional
50 Ohm
Vertical
1 x N-Type female
Bottom
75 W
Environmental Conditions
Operating Temperature
Storage Temperature
IP Rating
outdoor
-40C to 80C
-40C to 80C
IP67
outdoor
-40C to 80C
-40C to 80C
IP68
Material Data
Radom Color
Radom Material
Back plate/base plate material
Ordering Data
Model
802.11 a/b/g/h Wireless Antenna;
Directional
802.11 a/b/g/h Wireless Antenna;
Omni-directonal
Note:
222
Type
Part No.
1367140000
IE-ANT-P-ABG-75-9-NF
IE-ANT-O-ABG-360-7-NF
Mounting material included
1367130000
Mounting material included
Cables
IE-CC-NM-RPSMAM-2M
IE-CC-NM-RPSMAM-4M
50 Ohm +/- 2
6 Ghz
4.08 ns/m
approx. 0.55 dB/m
approx. 0.87 dB/m
50 Ohm +/- 2
6 Ghz
4.08 ns/m
approx. 0.55 dB/m
approx. 0.87 dB/m
2m
6.3 kg/100m
28 mm
Connector 1: N-type male
Connector 2: RP-SMA male
4m
6.3 kg/100m
28 mm
Connector 1: N-type male
Connector 2: RP-SMA male
-40C to 85C
-20C to 60C
IEC 60332-1, UL 1581 1080 (VW-1)
IEC 60754
ISO 4892-2A
-40C to 85C
-20C to 60C
IEC 60332-1, UL 1581 1080 (VW-1)
IEC 60754
ISO 4892-2A
Technical Data
Electrical Data
Impedance
Max. operating frequency
Signal delay
Attenuation @ 2.4 Ghz
Attenuation @ 5 Ghz
Mechanical Data
Length
Weight
Min. Bending radius (static)
Connector type
Environmental Limits
Operating Temperature
Installation Temperature
Flammability
Halogen free
UV resistance
Material Data
Jacket
Outer Diamter
Ordering Data
Models
Type
Antenna cable, 2m length N-type (male) --> IE-CC-NM-RPSMAM-2M
RP-SMA (male), Impedance 50 Ohm
Antenna cable, 4m length, N-type (male) -->
IE-CC-NM-RPSMAM-4M
RP-SMA (male), Impedance 50 Ohm
Part No.
1367110000
1367100000
223
Hardware Mounts
Mounts
WI-ACC-24GHZ4610DB-ANG-BRKT
WI-ACC-24GHZ4610DB-STR-BRKT
WI-ACC-24GHZ12DB-STR-BRKT
Type
WI-ACC-24GHZ-
4610DB-ANG-BRKT
Type
WI-ACC-24GHZ-
4610DB-STR-BRKT
Type
WI-ACC-24GHZ-
12DB-STR-BRKT
Technical Data
Description
Ordering Data
Part No.
6720005209
Part No.
6720005210
WI-ACC-MAGBASE
12 RG58 SMA MALE
WI-ACC-900MHZOMNI-STR-BRKT
WI-ACC-900MHZYAGI-STR-BRKT
Part No.
6720005211
Technical Data
Description
Ordering Data
Type
WI-ACC-MAGBASE 12
RG58 SMA MALE
Part No.
6720005263
Type
WI-ACC-900MHZ-
OMNI-STR-BRKT
Part No.
6720005268
Type
WI-ACC-900MHZ-
YAGI-STR-BRKT
WI-ACC-900MHZ14YAGI-STR-BRKT
WI-ACC-900MHZ035OMNI-STR-BRKT
WI-ACC-900MHZ7OMNI-STR-BRKT
Type
WI-ACC-900MHZ-
035OMNI-STR-BRKT
Type
WI-ACC-900MHZ-
7OMNI-STR-BRKT
Part No.
6720005266
Technical Data
Description
Ordering Data
224
Type
WI-ACC-900MHZ-
14YAGI-STR-BRKT
Part No.
6720005267
Part No.
6720005271
Part No.
6720005272
Surge Suppressor
WI-ACC-125-1000MHZ SURGE
NF-NF
WI-DIV-CCMA
SMA M SMA F
Technical Data
Connector
Frequency Range
VSWR
Insertion Loss
Turn-on
N female to N female
125 - 1000 MHz
<1.1 over frequency range
<0.1 dB over frequency range
600fb Vdc +/- 20%
N female to N female
2.0 - 6.0 GHz
1.3: 1
0.1 dB
Part No.
Type
WI-ACC-2-6GHZ
6720005262
SURGE NF-NF
Type
WI-DIV-CCMA
SMA M-SMAF
Ordering Data
Type
WI-ACC-125-1000MHZ
SURGE NF-NF
Antenna Coupler
Part No.
6720005261
WI-ACC-BULK-C1D1
SMA M - SMA M
WI-ACC-BULK-C1D1
SMA M - NM
0.6 dB
2.2 dB
2.6 dB
0.5 lb (0.23 kg)
300 Series Stainless Steel
-40/+85 C
3.2 dB
2.4 dB
4.1 dB
0.5 lb (0.23 kg)
300 Series Stainless Steel
-40/+85 C
Part No.
6720005111
Technical Data
Maximum Fault Voltage
Maximum Antenna Power Output
Maximum Capacitance
Frequency Range
Impedenance
Approximate Signal Attenuation (1):
@ 425 MHz
@ 915 MHz
@ 2.4 GHz
Approximate Weight
Housing Material
Ambient Temperature Range
Approvals
Ordering Data
Type
WI-ACC-BULK-C1D1
SMA M - SMA M
Part No.
6720005298
Type
WI-ACC-BULK-C1D1
SMA M - NM
Part No.
6720005299
225
Hardware Adapters
Adapters
WI-ACC-ADAPT
SMA M - SMA M
WI-ACC-ADAPT
SMA F - SMA F
WI-ACC-ADAPT
NM - NM
Technical Data
Connector
Adapter
SMA female to SMA female
Adapter
SMA male to SMA male
Barrel Adapter
N male to N male
Ordering Data
Type
WI-ACC-ADAPT
SMA M - SMA M
Part No.
6720005290
WI-ACC-ADAPT NF - NF
Type
WI-ACC-ADAPT
SMA F - SMA F
Part No.
6720005291
WI-ACC-ADAPT SMA F - NM
Type
WI-ACC-ADAPT
NM - NM
Part No.
6720005292
WI-ACC-ADAPT SMA M - NF
Technical Data
Connector
Barrel Adapter
N female to N female
Adapter
SMA female to N male
Adapter
SMA male to N female
Type
WI-ACC-ADAPT
SMA M - NF
Ordering Data
Type
WI-ACC-ADAPT
NF - NF
Part No.
6720005293
WI-ACC-ADAPT
SMA F - SMA M ANGL
WI-ACC-BULK
SMA F - SMA F
Technical Data
Connector
Bulkhead Adapter
SMA female to SMA female with D-flat
Ordering Data
226
Type
WI-ACC-BULK
SMA F - SMA F
Part No.
6720005296
Type
WI-ACC-ADAPT
SMA F - SMA M ANGL
Part No.
6720005297
Part No.
6720005295
Stainless steel
Stainless steel is a collective noun for all kinds of steel
(alloys) which are smelted in a special process and have a
high degree of purity. Stainless steel has a much-enhanced
resistance to corrosion. Weidmullers stainless steel terminal
rails have the following composition: X5 CrNi 18-10
stainless steel (i.e. 18 % chromium, 10 % nickel).
Aluminium
Aluminium is second only to copper in its electrical
conductivity. One advantage is its light weight. Aluminium
oxidises quickly in air; thus passivated, it offers excellent
corrosion protection.
Copper
Copper, a heavy metal, has the best electrical conductivity
of all metals used. As it is a soft metal, Weidmullers terminal
rails are 2.3 mm thick.
Plastic
The plastic terminal rail scores on two counts: firstly, its
insulating properties, and secondly, its low weight. This
leads to its use in special applications where, for example,
clearance and creepage distances with respect to the
mounting plate cannot be achieved with the standard
terminal rails.
Steel
The steel rail is the most widely used DIN-rail on the market.
Among metal DIN-rails, it has the lowest short-circuit
resistance, similar to stainless steel.
227
5.5 mm
15 mm
TS 15 x 5
Unperforated
Aluminium
Short-circuit strength
corresponds to E-Cu wire
TS 15x5 2M/AL/BK
16 mm2
max. permissible rated current for PEN function = 76 A)
Steel, galvanised and passivated
TS 15x5 2M/ST/ZN
10 mm2
Unperforated
Y
32 mm
1 mm
2m
10 m
0134700000
1 mm
2m
2m
0514200000
1 mm
1 mm
2m
1m
2m
10 m
0117500000
0117510000
Material thickness
Length
Qty.
1.5 mm
2m
2m
0169300000
1.5 mm
2m
2m
0122800000
35 mm2
1.5 mm
2m
2m
0293220000
Short-circuit strength
corresponds to E-Cu wire
35 mm2
Material thickness
Length
Qty.
Part No.
1.5 mm
2m
2m
0514400000
10 mm2
10 mm2
Aluminium
Short-circuit strength
corresponds to E-Cu wire
TS 32X15 2M/AL/BK
70 mm2
(max. permissible rated current for PEN function = 192 A)
Steel, galvanised and passivated
TS 32X15 2M/ST/ZN
35 mm2
228
Qty.
TS 32 x 15
Stainless steel
TS 32X15 2M/CRN
Length
Part No.
15 mm
TS 32 terminal rail
Material thickness
Part No.
7.5 mm
35 mm
TS 35 x 7.5
Unperforated
Aluminium
Short-circuit strength
corresponds to E-Cu wire
TS 35X7.5 2M/AL/BK
35 mm2
(max. permissible rated current for PEN function = 125 A)
Steel, galvanised and passivated
TS 35X7.5 2M/ST/ZN
16 mm2
TS 35X7.5 1M/ST/ZN
16 mm2
Stainless steel
TS 35X7.5 2M/CRN
16 mm2
Steel, galvanised and passivated
Length
Qty.
Part No.
1 mm
2m
2m
0330800000
1 mm
1 mm
2m
1m
2m
10 m
0383400000
0383410000
1 mm
2m
2m
1747350000
Material thickness
Length
Qty.
Part No.
TS 35X7.5/LL 2M/ST/ZN
TS 35X7.5/LL 1M/ST/ZN
Short-circuit strength
corresponds to E-Cu wire
16 mm2
16 mm2
1 mm
1 mm
2m
1m
2m
10 m
0514500000
0514510000
TS 35X7.5/LL/6 2M/ST/ZN
16 mm2
1 mm
2m
Material thickness
Length
Qty.
Part No.
2.3 mm
2m
2m
0270100000
2.3 mm
2m
2m
0498000000
2.3 mm
2m
2m
1848290000
Material thickness
Length
Qty.
Part No.
1.5 mm
2m
2m
0236400000
0514570000
2m
18
Material thickness
6.2
15 mm
TS 35 x 15 terminal rail
TS 35 x 15
35 mm
Copper
Short-circuit strength
corresponds to E-Cu wire
TS 35X15/2.3 2M/CU/BK
150 mm2
(max. permissible rated current for PEN function = 309 A)
Steel, galvanised and passivated
TS 35X15/2.3 2M/ST/ZN
50 mm2
Unperforated
Aluminium
TS 35X15/2.3 2M/AL/BK
70 mm2
(max. permissible rated current for PEN function = 192 A)
Steel, galvanised and passivated
Short-circuit strength
corresponds to E-Cu wire
TS 35X15 2M/ST/ZN
25 mm2
Unperforated
Material thickness
Length
Qty.
Part No.
TS 35X15/LL 2M/ST/ZN
TS 35X15/LL 1M/ST/ZN
Short-circuit strength
corresponds to E-Cu wire
25 mm2
25 mm2
1.5 mm
1.5 mm
2m
1m
2m
10 m
0236500000
0236510000
TS 35X15/LL/6x18 2M/ST/ZN
25 mm2
1.5 mm
2m
2m
1805980000
TS 35X15/LL/6x25 2M/ST/ZN
25 mm2
1.5 mm
2m
2m
1866290000
18
25
11
6.3
6.3
229
TS 35 x 15 terminal rail
15 mm
35 mm
Unperforated
TSK 35 x 15
Length
2m
Qty.
2m
Part No.
0514300000
Qty.
100
Part No.
1283470000
End cap TS 35 x 15
TS END CAP 35X15
100
1283480000
TS 35 end capsz
NEW
230
Colour
beige
Torque
0.4 Nm
Qty.
50
Part No.
0382860000
0.4 Nm
50
1071900000
20
7920340000
Torque
1.2 Nm
1.2 Nm
Qty.
50
50
Part No.
0199360000
0206160000
0.5 Nm
50
1067600000
Metal, screw-in
MEW 1/32
silver
2 Nm
20
0445600000
beige
Colour
beige
beige
EW 15
EW 15/2
ZEW 15
EWK 1
EWK 2
WEW 32/1
MEW 1/32
WEW 35/2
WEW 35/1
Colour
Torque
Qty.
dark beige
dark beige
grey
black
grey
black
1.2 Nm
0.5 Nm
1.2 Nm
1.2 Nm
0.5 Nm
0.5 Nm
50
100
50
50
100
100
1059000000
1061200000
1227890000
1162600000
1859200000
1061210000
beige
beige
grey
grey
black
20
20
20
20
20
9540000000
8630740000
1238040000
1227850000
1162610000
0383560000
0383530000
1269050000
1805610000
1805610000
ZEW 35/2
EW 35
Metal, screwable
MEW 35/1
beige
grey
dark beige
silver
0.5 Nm
0.5 Nm
5.5 Nm
50
50
50
10
silver
5.5 Nm
10
Part No.
MEW 35/1
231
Thread
M5
M5
M6
Qty.
10
10
10
Part No.
0178100000
1779100000
0164000000
10
10
1286600000
0101700000
50
50
50
0295900000
0642600000
0353500000
TST 2/M5
TST 2/M6
M5
M6
TSTW 5/M5
Fixing screws
FKSC M5x8 9
FKSC M6x8 9
FKSC M6x12 9
Weidmuller supplies fixing screws with hexagonal sockets and a very low
head for the terminal rail supports so that the terminals can also be fitted
over the screw.
TSTW 6/M6
232
TST
As experienced experts we support our customers and partners around the world
with products, solutions and services in the industrial environmment of power,
signal and data. We are at home in their industries and markets and know the
technological challenges of tomorrow. We are therefore continuously developing
innovative, sustainable and useful solutions for their individual needs. Together we
set standards in Industrial Connectivity.
Weidmuller, Canada
10 Spy Court
Markham, Ontario L3R 5H6
Telephone: (800) 268-4080
Facsimile: (877) 300-5635
Email: info1@weidmuller.ca
Website: www.weidmuller.ca
Weidmuller, Mexico
Blvd. Hermanos Serdn 698,
Col. San Rafael Oriente
Puebla, Puebla, Mexico
C.P. 72029
Telephone: 01 222 2686267
Facsimile: 01 222 2686219
Email: clientes@weidmuller.com.mx
Website: www.weidmuller.com.mx
4/14 LIT1315E