ULTRASONIC FLAW DETECTOR TUD210

ISO 9001

Features:

Real-time multi function system, stable, reliable and efficient operation

The embedded software can be updated online

Big memory of 400 A graph and 40000 thickness value

Super Fast sampling capability, RF wave full display

Wide & high bright EL display screen

Alternative switch between single probe and double probe

DAC automatically creation with standard test block

Li battery, continue working time up to 6 hours

USB and RS232 interface

Adjustability of DAC curve is available for various requirements of


DAC application

High speed sampling, radio frequency display with 80 MHz for


sampling Min. display range 2.5mm

Technical Specification
Test modes

Pulse-echo and dual

Pulse

Spike excitation pulse

Measuring range

2.5mm to 5000mm / 0.1inch to 200 inch

Sound speed

1000 m/s~9999m/s

Vertical linearity error


Dynamic range

3%
!32dB

Horizontal linearity error

0.2%
to +3400

Display delay

-20

Sensitivity leavings

!50dB

Probe delay

Gain

0-110 dB variable in selectable steps of 0.2,0.5 ,1,2,6,12, and locked

~99.99

, resolution 0.01

Damping

50 ohms, 150 ohms, and 400 ohms

Rectification

Full wave, positive half wave, negative half wave and RF

Bandwidth
Reject

0.2MHz~10MHz Low0.2~1, Mid.0.5~4, High 2~10


Linear, 0-80% of full screen, variable in steps of 1%

Scanning resolution

0.1mm (2.5mm~100mm)

Display screen

320240 pixels

Distance readout

Provide single echo or echo to echo thickness reading or sound path, surface, and depth
reading for angle beam testing with either peak or flank detection

Unit

mm/inch

1mm (100 mm~5000mm)

Interface

RS 232 and USB interface 9600 baud, 8 bits word length, no parity, 1 stop bit

Printer driver

TP UP-NH-S thermal printer

Power supply

Li batteries, continues working time approx. 6 hours

AC requirements

85 to 264V AC/1.0A, 47 to 63Hz

Charging time

5 hours maximum

Operating temperature
Storage temperature

0 to +40
-20 to +60

Dimensions

53184230mm

Weight

1.2 kg

Probe connector

LEMO

42

ULTRASONIC FLAW DETECTOR TUD210


ISO 9001

Dataview for TIME ultrasonic flaw detector TUD210

Standard Delivery

Main unit
Li battery
Neck strap
Power adapter
Couplant
Straight probe
Angle probe
Cable with LEMO connector
Protection case
Screwdriver
TIME certificate

Warranty card

Instruction manual

Optional Accessory

43

Various probes (see page 48)


Dataview for TUD210 ( software)
Connecting cable
Printer TP UP-NH

1
1
1
1
1
1
1
2
1
1
1

ULTRASONIC FLAW DETECTOR TUD300


ISO 9001

Features:

Measuring of pitch interval and analysis of echo times


Auto-calibration of probe and auto-gain
Two measuring unit: mm/inch
All built-in software can be up-graded on PC
Lock/unlock the system parameters
Equipped with gate setting and alarming function
Two measurement displaying mode: A-scan and B-scan
Freeze/defreeze waveform and detection parameters
Communicating with PC by RS232 port for transferring the measuring
data and system parameters
10 detecting channels are available with separated detecting
parameters and DAC curve in every channel
Automatic generation of DAC curve, and 30 points can be recorded
at most, adjustable offset curves and gain correction functions are
available
Provided with linear reject function, the highest range is 80% of the
screen height
Memory up to 300 A scanned images, parameters and DAC, and
30000 thickness values
Four Rectify Ways: positive half-wave, negative half-wave, full wave
and radio frequency
Three detecting modes: single-probe, dual-probe ones and transmission

Technical Specification
Scanning range

2.5 mm ~5000 mm

Scanning resolution

0.1mm (2.5mm~100mm) 1mm (100 mm~5000mm)

Gain range

0dB ~110 dB
~+3400

D-Delay

-20

P-Delay

Sound speed

1000 m/s~9999m/s

Bandwidth

0.2MHz~15MHzLow0.2~1 Mid.0.5~4 High 3~15


3%

Vertical linearity error


Horizontal linearity error

~99.99

, resolution 0.01

0.2%

Dynamic range

!32dB

Rectification

Positive half wave, negative wave, full wave, and RF

Sensitivity leavings

!60dB

Test mode

Pulse-echo, dual and through transmission

Pulser
Damping

Spike excitation pulser


50ohms, 150ohms and 400ohms

Reject

Linear, 0-80% of full screen, variable in steps of 1%

Unit

mm/inch

Standard Delivery

Main unit

Power adaptor

Neck strap

Cable for probe

Carrying case

Straight probe

Angle probe

Couplant

TIME certificate

Warranty card

Instruction manual

Optional Accessory

Interface

RS232

Connecting Cable

Printer

TP UP-NH-S line thermal printer

Dataview software for TUD300

AC requirements

85-264V AC/1.0A,47-63Hz

Printer TP UP-NH

Temperature

Various probes (see page 48)

Humidity

-10~40
20%~90%RH

Charging time

4~5 hours

Power supply
Overall dimension

Li battery 43.6V 4000mAh


24317370mm

Weight

1.47kg

44

ULTRASONIC FLAW DETECTOR TUD310


ISO 9001

Features:

Two measuring unit: mm/inch


Four Rectify Ways: positive half-wave, negative half-wave, full wave
and radio frequency
Two scanning mode: A and B
Gate alarming function
32 detecting channels are available with separated detecting parameters
and DAC curve in every channel
Automatic generation of DAC curve, and 30 points can be recorded
at most, adjustable offset curves and gain correction functions are
available
Three detecting modes: single-probe , dual-probe and transmission
Equipped with high-speed USB port and flash memory device can
be used directly on the instrument
Data and documents are managed under FAT file system, making the
management of inspection data more convenient, faster and more
reliant
Super large memory up to 32M, 1000 echo data can be stored in
32 detecting channels
Brand new digital signal circuit is designed for TUD310, Digital signal
processor (DSP) is used for signals analyzing, making circuit noise
reduced properly and waveform more stable
EPSON ink-jet printer can be connected with TUD310 by USB cable
Real-time waveform display and review

Technical Specification
Scanning rrange

2.5 mm ~9999 mm

Scanning resolution

0.1mm (2.5mm~100mm) 1mm (100 mm~5000mm)

Gain range

0dB ~110 dB

D-Delay

-20

P-Delay
Sound speed

resolution 0.01
1000 m/s~9999m/s

Bandwidth

0.2MHz~15MHz Low0.2~1 Mid.0.5~4 High 3~15

~+3400
~99.99

Vertical linearity error

3%

Horizontal linearity error

0.2%

Standard Delivery

Main unit

Power adaptor

1
1

Neck strap

Cable for probe

Carrying case

Straight probe

Angle probe

Dynamic range

!32dB

Couplant

Rectification

Positive half wave, negative wave, full wave, and RF

Flash disk

1
1

Sensitivity leavings

!60dB

TIME certificate

Test mode

Pulse-echo, dual and through transmission

Warranty card

Pulser

Spike excitation pulser

Instruction manual

Damping

50ohms, 150ohms and 400ohms

Reject

Linear, 0-80% of full screen, variable in steps of 1%

Unit

mm/inch

Interface

RS232 / USB

Dataview software for TUD310

Printer

EPSON ink-jet printers

Various probes (see page 48)

AC requirements

85-264V AC/1.0A,47-63Hz

EPSON ink-jet printer

Temperature
Humidity

-10~40
20%~90%RH

Charging time

4~5 hours

Power supply
Overall dimension

Li battery 43.6V 4000mAh


24317370mm

Weight

1.47kg

Optional
Accessory
Connecting
Cable

45

ULTRASONIC FLAW DETECTOR TUD320


ISO 9001

Features:

Color TFT display screen with backlight


Reference waves with different colors can be displayed at the same time
Curved surface correction: inspection of inner and outer curved
surface, auto-correcting the detecting result according to diameter
of curved surface
DGS (AVG) curve: special key is designed for 2 types of DGS curves:
flat-bottom hole and infinite plane
Real-time battery power indication, displayed by percentage
Displaying echo times during multi-times echo detecting in which
users are required to input the thickness value of work piece into
instrument
Automatic generation of DAC curve, and 30 points can be recorded
at most, adjustable offset curves and gain correction functions are
available
Three detecting modes: single-probe , dual-probe and transmission
Two scanning modes: A and B
Two measuring unit: mm/inch
Four Rectify Ways: positive half-wave, negative half-wave, full wave
and radio frequency
Gate alarming function
10 detecting channels are available with a separate detecting parameter
and DAC curve in every channel

Technical Specification
Scanning range

2.5 mm~5000mm

Scanning resolution

0.1mm (2.5mm~100mm) 1mm (100 mm~5000mm)

Gain range

0dB~110 dB

D-Delay

-20

P-Delay

Sound speed
Bandwidth

Standard Delivery

Main unit

Power adaptor

Neck strap

1000 m/s~9999m/s

Cable for probe

0.2MHz~15MHz Low0.2~1 Mid.0.5~4 High 3~15

Carrying case

~+3400
~99.99

resolution 0.01

Vertical linearity error

3%

Straight probe

Horizontal linearity error

0.2%

Angle probe

!32dB

Couplant

Rectification

Positive half wave, negative wave, full wave, and RF

TIME certificate

Sensitivity leavings

!60dB

Warranty card

Instruction manual

Dynamic range

Test mode

Pulse-echo, dual and through transmission

Pulser

Spike excitation pulser

Damping

50ohms, 150ohms and 400ohms

Reject

Linear, 0-80% of full screen, variable in steps of 1%

Unit

mm/inch

Interface

RS232

AC requirements

85-264V AC/1.0A ,47-63Hz

Temperature

-10~40

Humidity

20%~90%RH

Power supply

Li battery 43.6V 4000mAh

Charging time

4~5hours

Overall dimension

243173 70mm

Weight

1.47kg

Optional Accessory

46

Various probes (see page 48)

ULTRASONIC FLAW DETECTOR TUD360


ISO 9001

Features:

Sampling frequency reach up to 160MHz

Color TFT LCD display

Memory up to 1024 A scanned images, parameters and 64000


thickness values

32 detecting channels are available with separated detecting


parameters and DAC curve in every channel

Equipped with gate setting and alarming function

Two scanning modes: A scan and B scan

Auto gain and manual B scanning

USB 1.1, fullspeed communication port available

Can be connected with PC to print out result

Pulser voltage adjustable

Two measuring unit: mm/inch

Three detecting modes: single-probe, dual-probe and transmission

Real time waveform display and review

Four rectify ways: positive half-wave, negative half-way, full wave and
radio frequency

Technical Specification
Scanning range

2.5mm~9999mm

Frequency

0.1MHz~25MHz

Gain range

0dB~110dB

Standard Delivery
Main unit
Couplant

1
1

Power adaptor
Power cable for power adaptor

1
1

Neck strap

Connecting cable

Straight probe
Angle probe

1
1

Flash disk

Instruction manual

TIME certificate

Warranty card

Vertical linearity error

3%

Horizontal linearity error

0.2%

Dynamic range

!34dB

Rectification

Positive half wave, negative wave, full wave, and RF

Sensitivity leavings

!60dB

D-Delay

-20

P-Delay

~3400
~99.99

Scanning resolution

0.1mm(2.5mm~99.99mm):1mm(100mm~9999mm)

Sound velocity

1000m/s~9999m/s

Overall dimension

24317385mm

Weight

1500g

Test mode

Pulse-echo, dual and through transmission

Connecting cable

Damping

50 ohms,100 ohms, 150 ohms

Dataview software

EPSON ink-jet printer

Various probes(see page 48)

Unit

Optional Accessory

mm/inch

Interface

RS232/USB

Printer

EPSON ink-jet printer

Temperature

-10~40

Power supply

Li battery 43.6V

Humidity

20%~90%RH

47

ULTRASONIC FLAW DETECTOR TUD300/310/320/360


ISO 9001

Dataview for TIME ultrasonic flaw detector TUD300/310/360

Editing and management of saved data and echoes

Edit and print of examination report as users demand


Dataview for TUD310 and TUD360 is equipped with real-time display of detecting waves on the computer screen

Review of echo

Scroll and review data for examination

Edit and print of Examination Report

TIME ultrasonic probes


TIME supplies various kinds of ultrasonic probes as customers requirements

48

CALIBRATION BLOCK FOR ULTRASONIC FLAW DETECTOR


ISO 9001

V-1
Description:

25mm thickness of the block is used to test the dynamic range


of the flaw detector, horizontal linearity and adjustment of
p-wave detection range

50mm arc and 1.5mm hole is used to test the refraction


angle of angle beam probe and sensitivity leavings of
straight beam probe. It is also can be used to estimate the
blind area and the penetrating power

R100mm circular is used to test the incident point of angle


beam probe. blind area and adjust the timeline and the
zero

85mm, 91mm and 100mm is used to test the vertical resolution


of straight beam probe

Right-angle edge of the test block is used to test the deflection


angle of the sound beam

V-2
Description:

R50mm arc is used to test the refraction angle and sensitivity


leavings of angle beam probe

The reflector of 5mm hole can be used to detect the


refraction angle in the range of 45~65and 65~75

12.5mm bottom can be used to test the horizontal linearity


and the vertical linearity

R25mm and R50mm circular is used to adjust the timeline


and the zero

CSK-ACSK-ACSK-A

CSK-A

CSK-A

Description: CSK-A, CSK-A, CSK-A is suitable for welding joints with 6~120mm wall thickness.

49

CSK-A

CALIBRATION BLOCK FOR ULTRASONIC FLAW DETECTOR


ISO 9001

ASME-1#, ASME-2#, ASME-3#, ASME-4# ,ASME-5# ,ASME-6#

Thickness step check piece

The thickness is 1~10mm

Description: The size and dimension is as follows, L is determined


by the refraction angle and the material of the probe.

Unit:mm

Groove
(LWH)
50.850.38

25.4~50.8

38.1

200

3.2

50.850.76

50.8~101.6

76.2

250

4.8

50.851.52

101.6~152.4

127

381

6.4

50.852.54

152.4~203.2 177.8

534

7.9

50.853.56

686

9.5

50.854.57

203.2~254

228.6

22

2.4

18

150

CBI

14

19.05

The thickness is 3~48mm

10

Diameter

25.4

NO. Weld thickness t

Description: When the thickness of steel plate is less than 20mm, it


recommends using CBI.

50