Sie sind auf Seite 1von 6

Results of Tiab's Direct Synthesis Technique, TDST - Version 4.

2, January
2014
UPTEC
United Petroleum Technology Consultants
All Rights Reserved
Copyright 2001-2014

BASIC INFORMATION
Company
Field
Well

INPUT DATA
PARAMETER
Oil Volume Factor, Bo, bbl/STB

VALUE
1.229

Oil viscosity, cp

1.2

Oil flow rate, qo, BPD

250

Water Volume Factor, Bw, bbl/STB

Water viscosity, cp

Water flow rate, qw, BPD

Gas Volume Factor, Bg, ft^3/STB

Gas viscosity, cp

Gas flow rate, qg, MSCF/D

Porosity, %

1800

Total compressibility, ct, 1/psi

0.0003

Total flow rate, qt, STB/D

250

Formation thickness, ft

16

Wellbore radius, rw, ft

0.2666666666
66667

Reservoir temperature, T, F

120

Water saturation, %

Oil saturation, %

100

Gas saturation, %

Input Deviation angle, Deg.

Corr. Deviation angle, Deg.

OUTPUT DATA
PARAMETER

VALUE

OBTAINED FROM

k, md

243.7593

(t*dP')r

k, md

238.0718

ti

k, md

152.5084

(t*dp')x

29.0709

(t*dp)'r, tr & (dp)r

45.0116

tx and ti

Distance to boundary, ft

trpi

c, bbl/psi

0.04113

dpi and ti

c, bbl/psi

0.06534

tx and (t*dp')x

c, bbl/psi

0.04113

ti

Semilog slope, psi/cycle

-15.3714

dPskin, psi

388.14183

Flow Efficiency, FE, %

130.514

Damage Ratio, DR, %

76.62

Damage Factor, DF, %

-30.514

Productivity Index, J, bbl/psi

-0.2415

Pseudo skin factor slanted well

Ideal Productivity Index, Jideal, bbl/psi

-0.1851

Ideal Flow Rate, Qideal, bbl/day

191.55

Well damaged, a yearly lost of US$

2505986.4

Distance to the fault, ft

tRe - TDS

Distance to the fault, ft

(t)inf - Earlougher

Distance to the fault, ft

(t)inf - TDS

ASSOCIATED INPUT DATA


PARAMETER

VALUE

Well-Flowing Pressure, Pwf, psi

2272

Initial pressure, Pi, psi

2733

Initial water saturation, Swi

0.2

Residual oil saturation, Sor

0.15

Gauge depth, ft

6000

Datum depth, ft

7000

Fluid gradient, psi/ft

0.35

Gradient Pressure Correction, psi

350

Average Reservoir Pressure, Pave, psi

1000

Drainage Area, A, Acres

CHARACTERISTIC POINTS
PARAMETER

VALUE

MEANING

(t*dp')x, psi

132.4064

Maximum point during wellbore storage

tx, hr

Time of maximum point during wellbore storage

(dp)r, psi

443

Any point during radial flow

(t*dp')r, psi

6.6742

Derivative during radial flow

tr, hr

12

Any time during radial flow

ti, hr

0.022

Intersection time of radial & unit-slope line

(dp)i, psi

6.6742

Pressure at intersection time

trpi, hr

Intersection of radial and late pseudosteady state lines

(dP)rpi, psi

Pressure at intersection of radial and late steady state


lines

(t)pss, psi

Any time during late time flow line

(dp)pss, hr

Pressure @ (t)pss

(t*dP')pss, psi

Pressure derivative @ (t)pss

(t)max, hr

Maximum point - long reservoirs

(t)i2, hr

Intercept of early unit-slope and second radial derivative

(t*dP')r2, psi

Second radial derivative

RESULTS FROM SEMILOG ANALYSIS


PARAMETER

VALUE

k, md

m, psi/cycle

tSSL, hr

P1hr, psi

m*, psi/hr

Pint, psi

Area, Ac

Pave ( Dietz ), psi

lambda

omega

PRESSURE AND PRESSURE DERIVATIVE DATA


dt, hrs

P, psi

dP, psi

t*dP', psi

t^2*dP'', psi

0000.0000

02733.00

00000.00

00000.000

00000.000

0000.1000

02703.00

00030.00

00031.860

00000.000

0000.2000

02672.00

00061.00

00060.640

00000.000

0000.3000

02644.00

00089.00

00085.336

00000.000

0000.4000

02616.00

00117.00

00109.009

00000.000

0000.6500

02553.00

00180.00

00125.229

00000.000

0001.0000

02500.00

00233.00

00129.504

00000.000

0002.0000

02398.00

00335.00

00133.036

00000.000

0003.0000

02353.00

00380.00

00102.841

00000.000

0004.0000

02329.00

00404.00

00081.893

00000.000

0005.0000

02312.00

00421.00

00060.590

00000.000

0007.0000

02293.00

00440.00

00034.549

00000.000

0009.6000

02291.00

00442.00

00016.247

00000.000

0012.0000

02290.00

00443.00

00006.693

00000.000

0016.8000

02287.00

00446.00

00007.013

00000.000

0033.6000

02282.00

00451.00

00007.688

00000.000

0050.0000

02279.00

00454.00

00008.426

00000.000

0100.0000

02272.00

00461.00

00014.793

00000.000

*************************************************************************
********Pseudotime must be changed by time, and the unit are given in
hr************************************************************************
*********

SOFTWARE INFORMATION
Copyright 2001-2014, Dr. Djebbar Tiab and Dr.
Freddy H. Escobar
TDST Vr. 4.1 written by Dr. Freddy H. Escobar
Report date

23/10/2014

11:00:52 a. m.

Das könnte Ihnen auch gefallen