Beruflich Dokumente
Kultur Dokumente
Due to a policy of continuous improvement, Helvar reserve the right to alter specifications without notice at anytime.
www.helvar.com
Head Office
United Kingdom
Helvar Oy Ab
Helvar Ltd
Yrittjntie 23
FI - 03600 Karkkila
Finland
Hawley Mill
Hawley Road
Dartford
Kent, DA2 7SY
United Kingdom
Tel:
+358 9 5654 1
Tel:
Finland
Germany
Helvar Oy Ab
Helvar GmbH
Vetotie 3
FI-01610 Vantaa
Tel:
+358 9 5654 1
Philipp-Reis-Strae 4-8
DE-63150 Heusenstamm
Germany
Tel:
Italy
Sweden
Helvar S.r.l.
Helvar AB
sgatan 155
SE-11632 Stockholm
Sweden
Tel:
Tel:
+39 02 55 30 10 33
Hungary
Russia
Helvar Kft.
Lomb u. 31/b.
HU-1139 Budapest
Hungary
Sadovnicheskaya naberezhnaya 79
115035 Moscow
Russia
Tel:
Tel:
+ 7 (495) 743-34-82
France
China
Tel:
Tel:
4
11
20
24
28
30
32
33
35
38
40
41
42
43
46
52
55
62
67
72
74
75
76
77
80
81
84
86
88
89
91
92
94
Electronic ballasts
Magnetic ballasts
Quantity of ballasts for MCBs
Wire release instructions
EL-s wiring options
Lamp markings
98
100
102
108
109
110
iDim Concept
Minisensor
112
116
10
Dim sensors
117
123
125
230 V 50 Hz
240 V 50 Hz
220 V 50 Hz
Wiring diagrams, dimensions and delivery information
230 V 50 Hz
240 V 50 Hz
Wiring diagrams, dimensions and delivery information
Sensors
iDim Sense
Minisensor3
SL-PIR-SW, SL-PIR-AN SL-MW-SW,
SL-MW-AN, SL-MW-DA
MIMO2, MIMO3
140xxx
126
freedom in lighting
LED Drivers
Helvars LED offering includes a
range of Constant Current drivers
including dimmable and nondimmable solutions. The LED drivers
can be used for indoor and outdoor
applications for spot lights, down
lights, flood lights and linear strip
lighting.
The Helvar LED range is designed for easy installation and
long life. All drivers provide power with high efficiency. The
Home
Outlook
Further exciting LED product developments are in
the pipeline for 2013, showing Helvars continuous
commitment to supporting luminaire manufacturers in
making a successful transition to LED. Stay in tune with
our website for continuous new LED products.
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Prev
Next
DMX
Max.output
Power
DALI
Home
1 - 10 V
Switching
LL6-U-CC
11
LL20-U-CC
20
12
20
30
13
Driver type
LL1x20-E-DA
LC1x30-E-CC
LC1x30-E-AN
LC1x30-E-DA
LL2x35-E-DA
LL1x70-E-CC
LL1x70-E-DA
LL2x35-E-CC
LL1x40-E-CC
LL1x40-E-DA
Page
30
30
40
14
40
2x35
16
2x35
70
15
70
OL1x60-E-CC
63
17
OL1x100-E-CC1
105
18
OL1x100-E-CC2
101
19
50
10
LC50-U-DX3
Prev
Next
Helvar | Data is subject to change without notice. More information at: www.helvar.com
LL1x20-E-DA *
1x20 W Dimmable DALI LED driver
20 W 220 - 240 V, 50 - 60 Hz
* Preliminary information. For availability please check with your sales representative
Connections
Alternative
parallel connection
L
N
(+)
Next
Itot = 350 / 500 / 700 mA
Switch-Control
I2
I1
Ifv = I1 + I2 + ... + In
= 350 / 500 / 700 mA +/- 5%
Mains Characteristics
Voltage range
198 - 264 VAC
DC range
176 - 280 VDC,
starting voltage > 190 VDC
Max mains current at full load 0.09 - 0.12 A
Frequency
0 / 50 - 60 Hz
U-OUTmax (abnormal)
80 V
Stand-by power
0.3 W
Wire size
0.5 - 1.5 mm2
Wire type
solid core and fine-stranded
Maximum driver to LED wire length 5m
Weight 110 g
IP rating IP20
Load Output
Output current
350 / 500 / 700 mA
20 W
Max output power
Efficiency, at full load, typical 0.86
I-OUT
P-out (max)
U-OUT
@ max
350 mA
20 W
10-57 V
0.89c
0.86
500 mA
20 W
10-40 V
0.92c
0.86
700 mA
19.6 W
10-28 V
0.92c
0.86
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Prev
In
(-)
DALI
Home
LC1x30-E-DA
1x30 W Dimmable DALI LED driver
Selectable constant current output: 350 / 500
/ 700 mA
(custom currents on request)
Maximum 30 W load
DALI control input, 1 %-100 % dimming range
Low stand-by power 0.3 W
Protected up to 4 kV power network fast transients
High efficiency, 0.86
Optional click-on strain relief for independent use
External NTC thermal input
iDim compatible
Connections
L
N
DALI
Alternative
parallel connection
Home
Prev
Switch-Control
In
NTC
Next
I2
(-)
(+)
I1
Ifv = 350 / 500 / 700 mA
Ifv
Ifv = I1 + I2 + ... + In
= 350 / 500 / 700 mA +/- 5%
Mains Characteristics
Voltage range
198 - 264 VAC
DC range
176 - 280 VDC,
starting voltage > 190 VDC
Max mains current at full load 0.14-0.18 A
Frequency
0 / 50 - 60 Hz
80 V
U-OUTmax (abnormal)
Stand-by power
0.3 W
Wire size
0.5 - 1.5 mm2
Wire type
solid core and fine-stranded
Maximum driver to LED wire length 5m (1 m with NTC)
Weight 123 g
(+17 g, strain relief LC1x30-SR)
Thermal sensor input
Input for external
NTC thermal sensor
NTC trigger point
8.2 k
IP rating IP20
Load Output
Output current (I-OUT)
350 / 500 / 700 mA
(custom output currents 245-700 mA on request)
Max output power
30 W
Efficiency, at full load, typical 0.86
I-OUT
P-out (max)
U-OUT
@ max
350 mA
21 W
10 - 60 V
0.90c
0.86
500 mA
30 W
10 - 60 V
0.94c
0.86
700 mA
30 W
10 - 43 V
0.94c
0.86
Helvar | Data is subject to change without notice. More information at: www.helvar.com
17.04.2013 1/1
LC1x30-E-AN
1x30 W Dimmable 1-10 V LED driver
Selectable constant current output: 350 / 500
/ 700 mA
Maximum 30 W load
Connections
Alternative
parallel connection
L
N
1-10 V
NTC
Home
In
Prev
I2
Next
(-)
(+)
I1
Ifv = 350 / 500 / 700 mA
Ifv
Ifv = I1 + I2 + ... + In
= 350 / 500 / 700 mA +/- 5%
Mains Characteristics
Voltage range
198 - 264 VAC
DC range
176 - 280 VDC,
starting voltage > 190 VDC
Max mains current at full load 0.14-0.18 A
Frequency
0 / 50 - 60 Hz
80 V
U-OUTmax (abnormal)
Wire size
0.5 - 1.5 mm2
Wire type
solid core and fine-stranded
Maximum driver to LED wire length 5m (1 m with NTC)
Weight 126 g
(+17 g, strain relief LC1x30-SR)
Thermal sensor input
Input for external
NTC thermal sensor
NTC trigger point
8.2 k
IP rating IP20
Load Output
Output current (I-OUT)
350 / 500 / 700 mA
Max output power
30 W
Efficiency, at full load, typical 0.86
I-OUT
P-out (max)
U-OUT
@ max
350 mA
21 W
10 - 60 V
0.90c
0.86
500 mA
30 W
10 - 60 V
0.94c
0.86
700 mA
30 W
10 - 43 V
0.94c
0.86
Helvar | Data is subject to change without notice. More information at: www.helvar.com
17.04.2013 1/1
LL1x40-E-DA *
1x40 W Dimmable DALI LED driver
Adjustable constant current output: 350 mA (default) - 1050 mA
Connections
Alternative
parallel connection
Home
In
I2
Prev
I1
Ifv = I1 + I2 + ... + In
Switch-Control
Next
DALI
NTC
L
N
R
Mains Characteristics
Voltage range
198 - 264 VAC
DC range
176 - 280 VDC,
starting voltage > 190 VDC
Max mains current at full load 0.18-0.23 A
Frequency
0 / 50 - 60 Hz
100 V
U-OUTmax (abnormal)
Stand-by power
0.4 W
Wire size
0.5 - 1.5 mm2
Wire type
solid core and fine-stranded
Maximum driver to LED wire length 5m (1 m with NTC)
Weight 150 g
(+10 g, strain relief LL1x40-SR)
Thermal sensor input
Input for external
NTC thermal sensor
NTC trigger point
8.2 k
IP rating IP20
Load Output
Output current (I-OUT)
350 mA (default) - 1050 mA
40 W
Max output power
Efficiency, at full load, typical 0.89
I-OUT
P-out (max)
350 mA
1050 mA
28 W
40 W
20 - 80 V
20 - 38 V
0.95
0.97
@ max
0.89
0.86
U-OUT
Helvar | Data is subject to change without notice. More information at: www.helvar.com
LL1x70-E-DA
1x70 W Dimmable DALI LED driver
Adjustable constant current output: 350 mA
(default) - 700 mA
Dali control input 1 %-100 % dimming range
Connections
Home
Ifv = 350 - 700 mA
Prev
L
N
R
DA
Next
Switch-Control
Note:
Not suitable for load side switching operation.
Driver output and current setting circuit are not isolated from mains
output Ifv
350mA
500mA
700mA
Mains Characteristics
Voltage range
198 - 264 VAC
DC range
176 - 280 VDC,
starting voltage > 195 VDC
Max mains current at full load 0.33- 0.42 A
Frequency
0 / 50 - 60 Hz
400 V
U-OUTmax (abnormal)
Stand-by power
0.4 W
Load Output
Output current (I-OUT)
350 mA (default) - 700 mA
70 W
Max output power
Efficiency, at full load, typical 0.91
I-OUT
P-out (max)
U-OUT
@ max
350 mA
70 W
50 - 200 V
0.98
0.91
700 mA
70 W
50 - 100 V
0.98
0.91
75 C
-20+50 C *
-40+80 C
no condensation
50 000h, at TC max
(90 % survival rate)
Helvar | Data is subject to change without notice. More information at: www.helvar.com
17.04.2013 1/1
LL2x35-E-DA *
2x35 W Dimmable DALI LED driver
Adjustable constant current output: 350 mA
(default) - 700 mA
Two independent SELV rated output channels
Connections
Home
Prev
L
N
R
DA
Switch-Control
Next
NTC
Note:
Not suitable for load side switching operation.
Wrong wiring will serious damage the product
PE needs not to be connected in class II luminaires if they are suitably designed
output Ifv
350mA
700mA
Mains Characteristics
Voltage range
198 - 264 VAC
DC range
176 - 280 VDC,
starting voltage > 190 VDC
Max mains current at full load 0.33- 0.42 A
Frequency
0 / 50 - 60 Hz
120 V
U-OUTmax (abnormal)
Stand-by power
0.5 W
Load Output
Output current (I-OUT)
350 mA (default) - 700 mA
35 W / channel
Max output power
Efficiency, at full load, typical 0.9
I-OUT 350 mA
P-out (max) / channel 35 W / ch
U-OUT 25-100 V
(both channels loaded) 0.98
(both ch loaded @ max) 0.9
700 mA
35 W / ch
25-50 V
0.98
0.87
80 C
-20+50 C
-40+80 C
no condensation
50 000h, at TC max
(90 % survival rate)
Helvar | Data is subject to change without notice. More information at: www.helvar.com
LC50-U-DX3
3 channel DMX LED driver 50 W
Max. total output power 50 W
Smooth dimming range 0.1 % - 100 %
Connections
Ch1
Ch2
Ch3
(+)
Home
(-)
(+)
(-)
Prev
(+)
(-)
(+)
(-)
(+)
DMX in (-)
NTC
NTC
(shield)
Next
DMX in (+)
DMX in (-)
DMX in (shield)
GND
L
Mains Characteristics
Voltage range
Max mains current at full load
Frequency
U-OUTmax (abnormal)
90 - 305 VAC
0.30 - 0.60 A
50 / 60 Hz
60 V
Load Output
Output current (default)
350 mA
Output current range (programmable) 350-1050 mA
Max. total output power
Max. individual channel power
Efficiency, at full load, typical
I-OUT
P-out (max)
U-OUT
@ max
350 mA
50 W
10 - 55 V
> 0.9c
0.89
50 W
50 W
0.89
350 - 1050 mA
50 W
10 - 55 V
> 0.9c
0.89
Wire size
0.5 - 1.5 mm2
Wire type
solid core and fine-stranded
Maximum driver to LED wire length 5 m
Weight 350 g
IP rating 20
Helvar | Data is subject to change without notice. More information at: www.helvar.com
17.04.2013 1/1
LL6-U-CC
1x6 W Constant Current LED driver
Selectable constant current output: 350 / 700
mA
6 W 100 - 240 V, 50 - 60 Hz
Connections
Home
Prev
(-)
I2
Itot = 350 / 700 mA
I1
L
N
Next
(+)
Ifv
Ifv = I1 + I2 + ... + In
= 350 / 700 mA +/- 5%
Mains Characteristics
Voltage range
Max mains current at full load
Frequency
Maximum circuit power
U-OUTmax (abnormal)
85 - 264 VAC
100 - 264 VDC
50 mA (at 240 VAC)
140 mA (at 100 VAC)
0 / 50 - 60 Hz
9W
25 V
Load Output
Output current
Efficiency, at full load, typical
Max output power
I-OUT
P-out (max)
U-OUT
@ max
350 mA
5.6 W
716
82
80
350 / 700 mA
0.80
7.0 W
700 mA
7.0 W
710
85
80
80 C
-20+60 C
-40+80 C
no condensation
50 000h, at tc max
(90 % survival rate)
Wire size
0.5 - 1.5 mm2
Wire type
solid core and fine-stranded
Maximum driver to LED wire length 5 m
Weight 65 g
IP rating 20
17.04.2013 1/1
11
LL20-U-CC
1x20 W Constant Current LED driver
Selectable constant current output: 350 / 700
mA
20 W 100 - 240 V, 50 - 60 Hz
Connections
2 A max
Home
(+)
L
N
Alternative
parallel connection
In
(-)
Prev
Itot = 350 / 700 mA
I2
Next
I1
Ifv = I1 + I2 + ... + In
= 350 / 700 mA +/- 5%
* max number of converters depends on supply voltage and load (7 pcs. max at full load)
Mains Characteristics
Voltage range
Max mains current at full load
Frequency
Maximum circuit power
U-OUTmax (abnormal)
85 - 264 VAC
100 - 264 VDC
100 mA (at 240 VAC)
230 mA (at 100 VAC)
0 / 50 - 60 Hz
23 W
50 V
Load Output
Output current
Efficiency, at full load, typical
Max output power
I-OUT 350 mA
P-out (max) 15 W
U-OUT 1243
86
@ max 85
350 / 700 mA
0.86
20 W
700 mA
20.3 W
1229
87
86
Wire size
0.5 - 1.5 mm2
Wire type
solid core and fine-stranded
Maximum driver to LED wire length 5m
Weight 110 g
IP rating 20
80 C
-20+60 C
-40+80 C
no condensation
50 000h, at TC max
(90 % survival rate)
Helvar | Data is subject to change without notice. More information at: www.helvar.com
17.04.2013 1/1
LC1x30-E-CC
1x30 W Constant Current LED driver
Selectable constant current output: 350 / 500
/ 700 mA (fixed)
Maximum 30 W load
Connections
Alternative
parallel connection
L
N
Home
Prev
In
NTC
Next
I2
(-)
(+)
I1
Ifv = 350 / 500 / 700 mA
Ifv
Ifv = I1 + I2 + ... + In
= 350 / 500 / 700 mA +/- 5%
Mains Characteristics
Voltage range
198 - 264 VAC
DC range
176 - 280 VDC,
starting voltage > 190 VDC
Max mains current at full load0.14-0.18 A
Frequency
0 / 50 - 60 Hz
80 V
U-OUTmax (abnormal)
Wire size
0.5 - 1.5 mm2
Wire type
solid core and fine-stranded
Maximum driver to LED wire length 5m (1 m with NTC)
Weight 115 g
(+17 g, strain relief LC1x30-SR)
Thermal sensor input
Input for external
NTC thermal sensor
NTC trigger point
8.2 k
IP rating IP20
Load Output
Output current (I-OUT)
350 / 500 / 700 mA
Max output power
30 W
Efficiency, at full load, typical 0.86
I-OUT
P-out (max)
U-OUT
@ max
350 mA
21 W
10 - 60 V
0.93c
0.86
500 mA
30 W
10 - 60 V
0.96
0.86
700 mA
30 W
10 - 43 V
0.96
0.86
17.04.2013 1/1
13
LL1x40-E-CC *
1x40 W Constant Current LED driver
Adjustable constant current output: 350 mA
(default) - 1050 mA
Protected up to 4kV power network fast transients
* Preliminary information. For availability please check with your sales representative
Connections
In
Home
I2
Prev
Ifv = I1 + I2 + ... + In
NTC
L
N
R
Mains Characteristics
Voltage range
198 - 264 VAC
DC range
176 - 280 VDC,
starting voltage > 190 VDC
Max mains current at full load 0.18-0.23 A
Frequency
0 / 50 - 60 Hz
100 V
U-OUTmax (abnormal)
Wire size
0.5 - 1.5 mm2
Wire type
solid core and fine-stranded
Maximum driver to LED wire length 5m (1 m with NTC)
Weight 150 g
(+17 g, strain relief LL1x40-SR)
Thermal sensor input
Input for external
NTC thermal sensor
NTC trigger point
8.2 k
IP rating IP20
Load Output
Output current (I-OUT)
350 mA (default) - 1050 mA
Max output power
40 W
Efficiency, at full load, typical 0.89
I-OUT
P-out (max)
U-OUT
@ max
350 mA
28 W
20 - 80 V
0.95
0.89
1050 mA
40 W
20 - 38 V
0.97
0.86
75 C
-20+50 C
-40+80 C
no condensation
50 000h, at TC max
(90 % survival rate)
Next
Helvar | Data is subject to change without notice. More information at: www.helvar.com
LL1x70-E-CC
1x70 W Constant Current LED driver
Overload, short & open circuit protection
Suitable for class I luminaires
Connections
Home
Ifv = 350 - 700 mA
Prev
L
N
R
Next
Current setting (p. 21)
Resistor R
output Ifv
open
350mA
8.2 k
500mA
0
700mA
Note:
Not suitable for load side switching operation.
Driver output and current setting circuit are not isolated from mains
Mains Characteristics
Voltage range
198 - 264 VAC
DC range
176 - 280 VDC,
starting voltage > 195 VDC
Max mains current at full load 0.32 - 0.41 A
Frequency
0 / 50 - 60 Hz
400 V
U-OUTmax (abnormal)
Wire size
0.5 - 1.5 mm2
Wire type
solid core and fine-stranded
Maximum driver to LED wire length 5 m
Weight 227 g
IP rating IP20
Load Output
Output current (I-OUT)
350 (default) to 700 mA
Max output power
70 W
Efficiency, at full load, typical > 0.91
I-OUT
P-out (max)
U-OUT
@ max
350 mA
70 W
50 - 200 V
0.98
0.91
700 mA
70 W
50 - 100 V
0.98
0.89
75 C
-20+50 C
-40+80 C
no condensation
50 000 h, at TC max
(90 % survival rate)
17.04.2013 1/1
15
LL2x35-E-CC *
2x35 W Constant Current LED driver
Adjustable constant current output: 350 mA (default) - 700 mA
Two independent SELV rated output channels
* Preliminary information. For availability please check with your sales representative.
Connections
Home
Prev
Next
NTC
Note:
Not suitable for load side switching operation.
Wrong wiring will serious damage the product
PE needs not to be connected in class II luminaires if they are suitably designed
Mains Characteristics
Voltage range
198 - 264 VAC
DC range
176 - 280 VDC,
starting voltage > 190 VDC
Max mains current at full load 0.33- 0.42 A
Frequency
0 / 50 - 60 Hz
120 V
U-OUTmax (abnormal)
Load Output
Output current (I-OUT)
350 mA (default) - 700 mA
Max output power
35 W / channel
Efficiency, at full load, typical 0.91
I-OUT
P-out (max) / channel
U-OUT
(both channels loaded)
(both ch loaded @ max)
350 mA
35 W / ch
25-100 V
0.98
0.91
700 mA
35 W / ch
25-50 V
0.98
0.88
Max.temperature at tc point 80 C
Ambient temperature range -20+50 C
Storage temperature range -40+80 C
Maximum relative humidity no condensation
Life time
50 000h, at TC max
(90 % survival rate)
output Ifv
350mA
700mA
Helvar | Data is subject to change without notice. More information at: www.helvar.com
OL1x60-E-CC
1x60 W Constant Current LED driver
Selectable constant current output: 350 / 700
/ 1400 mA
Maximum 63 W load
17
Connections
Alternative
parallel connection
Home
Prev
In
(+)
L
N
E
Next
I2
(-)
I1
Ifv
Ifv = I1 + I2 + ... + In
= 350 / 700 / 1400 mA +/- 5%
Mains Characteristics
Voltage range
198 - 264 VAC
Max mains current at full load 0.25 - 0.34 A
Frequency
50 - 60 Hz
113 V
U-OUTmax (abnormal)
Load Output
I-OUT
P-out (max)
U-OUT
@ max
350 mA
31.5 W
60 - 90 V
0.94c
0.86
700 mA
63 W
35 - 90 V
0.97
0.9
1400 mA
58.8 W
35 - 42 V
0.98
0.9
85 C
-30+60 C
-40+80 C
100 %
50 000 h, at 75 C TC
30 000 h, at 85 C TC
(90 % survival rate)
17.04.2013 1/1
17
OL1x100-E-CC1
1x100 W Constant Current LED driver
Selectable constant current output: 700 / 1050
mA
18
Connections
Alternative
parallel connection
Home
In
(+)
L
N
E
Prev
I2
Next
(-)
Itot = 700 / 1050 mA
I1
Ifv
Ifv = I1 + I2 + ... + In
= 700 / 1050 mA +/- 5%
Mains Characteristics
Voltage range
198 - 264 VAC
Max mains current at full load 0.44 - 0.58 A
Frequency
50 - 60 Hz
144 V
U-OUTmax (abnormal)
Load Output
I-OUT
P-out (max)
U-OUT
@ max
700 mA
84 W
70 - 120 V
0.98
0.91
1050 mA
105 W
70 - 100 V
0.98
0.91
85 C
-30+60 C
-40+80 C
100 %
50 000 h, at 75 C TC
30 000 h, at 85 C TC
(90 % survival rate)
Helvar | Data is subject to change without notice. More information at: www.helvar.com
17.04.2013 1/1
OL1x100-E-CC2
1x100 W Constant Current LED driver
Selectable constant current output: 1400 / 2100
mA
18
Connections
Home
Alternative
parallel connection
Prev
In
(+)
L
N
E
Next
I2
(-)
Itot = 1400 / 2100 mA
I1
Ifv
Ifv = I1 + I2 + ... + In
= 1400 / 2100 mA +/- 5%
Mains Characteristics
Voltage range
198 - 264 VAC
Max mains current at full load 0.44 - 0.58 A
Frequency
50 - 60 Hz
92 V
U-OUTmax (abnormal)
Load Output
I-OUT
P-out (max)
U-OUT
@ max
1400 mA
101 W
30 - 72 V
0.98
0.91
2100 mA
101 W
30 - 48 V
0.98
0.90
85 C
-30+60 C
-40+80 C
100 %
50 000 h, at 75 C TC
30 000 h, at 85 C TC
(90 % survival rate)
17.04.2013 1/1
19
Helvar have a range of LED drivers suited for either in-built and independent luminaire usage. In order to have safe and reliable LED driver
operation, the LED luminaires will need to comply with the relevant standards and regulations (e.g. IEC/EN 60598-1). The LED luminaire
shall be designed to adequately protect the LED drivers from dust, moisture and pollution. The luminaire manufacturer is responsible for
the correct choice and installation of the LED drivers according to the application and product datasheets. Specifications of the LED drivers
may never exceed the operating conditions as per the product datasheets.
Wiring considerations
Maximum tc temperature
Wiring insulation
According to recommendations in EN 60598
Maximum wire lengths
Home
Ensure that the LED driver does not exceed temperature higher
than specified on the product datasheets.
Prev
Switch-Control
The Helvar DALI dimmable LED drivers feature Switch-Control.
This feature provides basic On/Off and Up/Down dimming
functionality through a standard momentary switch.
Switch-Control and DALI controls may not be connected
simultaneously.
For more accurate Switch-Control operational information
please refer to page 35 (EB section)
When using a SELV-rated LED driver, then the SELV driver output
has to be insulated from the luminaire earth connection (ref.
EN60598-1 luminaire standard).
20
Helvar | Data is subject to change without notice. More information at: www.helvar.com
L
N
Switch-Control
Next
Home
(mA)
Prev
1k 1k2 1k5 1k8 2k2 2k7 3k3 3k9 4k7 5k6 6k8 8k2 10k 12k 15k 22k 27k 33k 39k 47k 56k 68k 82k 100k 150k 330k 1M
700 650 640 630 620 610 600 580 570 550 530 520 500 480 470 450 430 420 410 400 390 385 380 375 370 365 360 355 350
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Next
21
Dimensions
25.2
21.2
1
110
175
40
40
4
4.
4
4.
100
118
165
184
4
Home
4.2
Prev
57.5
Next
4.2
57.5
67
106
103
93.5
127
130
119
76
66.5
30
6
28
184
22
Helvar | Data is subject to change without notice. More information at: www.helvar.com
36.5
46.5
36.5
168
225
8
21
Home
Prev
370
35
Next
380
9
300 20
35
53
300 20
125
137
149
10
300 20
35
53
300 20
210
220
234
1
2
3
4
5
LL6-U-CC
LL20-U-CC, LL1x20-E-DA
LC1x30-E-CC, LC1x30-E-DA, LC1x30-E-AN
LC1x30-E-CC, LC1x30-E-DA, LC1x30-E-AN (+ LC1x30-SR)
LC50-U-DX3
6
7
8
9
10
Helvar | Data is subject to change without notice. More information at: www.helvar.com
23
LC1x30-SR
Easy to assemble click-on strain relief for LC1x30 series
Allows independent driver usage
Screws for internal cable clamps included
Cable clamps allowing different cable thicknesses
LL1x40-SR
Home
Prev
LC50-PR
USB to DMX programming dongle for the LC50-U-DX3
Configuring the LED driver parameters
Setting the LED driver DMX start address
Helvar DMX LED configurator Software downloadable from:
www.helvar.com/downloads/tools
For more information please see Technical note LED-TN-005 LC50-U-DX3 Operational & Configuration information
24
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Next
Home
Prev
Next
Helvar | Data is subject to change without notice. More information at: www.helvar.com
25
freedom in lighting
electronic Ballasts
One of the first companies to develop
and manufacture electronic ballasts,
Helvars history in these products
extends back to the early 1980s.
Since that time, Helvar has remained at the forefront,
offering a comprehensive range of innovative electronic
ballasts covering all relevant applications with T5, T8 and
compact fluorescent lamps. The tables below show lamp
categories where ballast combinations are found.
Home
Prev
Next
For compact
lamps
For T8 lamps
For T5 lamps
Page
28
30
31
EL-iDim-c
32
32
38
40
41
48
53
61
EL-su
50
53
61
EL-ngn
52
EL-ngn5
46
55
EL-es
54
EL-TCs
57
57
55
66
EP-h
26
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
Helvar | Data is subject to change without notice. More information at: www.helvar.com
27
EL-iDim
Digital DALI electronic ballasts for T5 fluorescent lamps
14-80 W 220-240 V, 50-60 Hz
A1 BAT
Lamp
type
Wattage
No. of
lamps
14
14
14
14
21
21
24
24
28
28
35
35
39
39
49
49
54
54
80
80
1
2
3
4
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
T5
Ballast
EL1x14-35iDim
EL2x14-35iDim
EL3x14iDim
EL4x14iDim
EL1x14-35iDim
EL2x14-35iDim
EL1x24iDim
EL2x24iDim
EL1x14-35iDim
EL2x14-35iDim
EL1x14-35iDim
EL2x14-35iDim
EL1x39iDim
EL2x39iDim
EL1x49iDim
EL2x49iDim
EL1x54iDim
EL2x54iDim
EL1x80iDim
EL2x80iDim
EEI
Dimensions Connection
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
1
2
2
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
(p.33)
1
2
3
4
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
Weight
Circuit
power
Mains
current
Lamp
power
(g)
250
330
310
330
250
330
250
330
250
330
250
330
250
330
250
330
250
330
250
365
(W)
17
32.5
47.5
62
23.5
46
25.5
50.5
32
62
39
73.5
42.5
82.5
55
107.5
59
117
86
170
(A)
0.08-0.07
0.15-0.14
0.22-0.20
0.29-0.27
0.11-0.10
0.22-0.20
0.12-0.10
0.23-0.21
0.15-0.14
0.28-0.26
0.18-0.17
0.36-0.30
0.20-0.18
0.38-0.35
0.25-0.23
0.49-0.45
0.27-0.25
0.53-0.49
0.39-0.36
0.78-0.70
(W)
13.7
13.7
13.7
13.7
20.7
20.7
22.5
22.5
27.8
27.8
34.7
34.7
38
38
49.3
49.3
53.8
53.8
80
80
Note: See pages 33- 35 for connection diagrams and additional characteristics.
* Dimming range 3-100 % for EL3x14iDim & EL4x14iDim
Dimensions
Length 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
360
30
21
350
2
430
30
21
420
d
c
a
b
d
Ballast
EL1 x iDim
EL2 x iDim
EL3 x iDim
EL4 x iDim
Delivery information
Transportation package
Unit package
Minimum Plastic
EUR pallet
Pallet
Pallet
delivery binding
1200 x 800
weight
height
amount
strip
(pcs.)
(kg)
(cm)
10
980
300
40
840
325
43
10
840
325
43
10
840
325
43
10
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
EL-iDim
Digital DALI electronic ballasts for T5-eco fluorescent lamps
14-80 W 220-240 V, 50-60 Hz
A1 BAT
Lamp
type
T5
eco
Wattage
No. of
lamps
14 eco
14 eco
14 eco
14 eco
21 eco
21 eco
24 eco
24 eco
28 eco
28 eco
35 eco
35 eco
49 eco
49 eco
54 eco
54 eco
80 eco
80 eco
1
2
3
4
1
2
1
2
1
2
1
2
1
2
1
2
1
2
Ballast
EL1x14-35iDim 4)
EL2x14-35iDim 4)
EL3x14iDim 1) 4)
EL4x14iDim 1) 4)
EL1x14-35iDim 4)
EL2x14-35iDim 4)
EL1x24iDim 3)
EL2x24iDim 3)
EL1x14-35iDim 4)
EL2x14-35iDim 4)
EL1x14-35iDim 4)
EL2x14-35iDim 4)
EL1x49iDim 3)
EL2x49iDim 3)
EL1x54iDim 3)
EL2x54iDim 3)
EL1x80iDim 3)
EL2x80iDim 3)
EEI
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
Dimensions Connection
(p.33)
1
2
3
4
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
2
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
Weight
Circuit
power 2)
Mains
current 2)
Lamp
power 2)
(g)
250
330
310
330
250
330
250
330
250
330
250
330
250
330
250
330
250
365
(W)
17
32.5
47.5
62
23.5
46
25.5
50.5
32
62
39
73.5
55
107.5
59
117
86
170
(A)
0.08-0.07
0.15-0.14
0.22-0.20
0.29-0.27
0.11-0.10
0.22-0.20
0.12-0.10
0.23-0.21
0.15-0.14
0.28-0.26
0.18-0.17
0.36-0.30
0.25-0.23
0.49-0.45
0.27-0.25
0.53-0.49
0.39-0.36
0.78-0.70
(W)
13.7
13.7
13.7
13.7
20.7
20.7
22.5
22.5
27.8
27.8
34.7
34.7
49.3
49.3
53.8
53.8
80
80
Home
Prev
Next
Note: See pages 33- 35 for connection diagrams and additional characteristics.
1) Dimming range 3-100 % for EL3x14iDim & EL4x14iDim
2) Maximum values at 100 % dimming level
3) Powercontrolled products, no energy saving when ecolamps are used. Lamps are running over powered.
4) Current controlled products, maximum 10 % energy saving achieved from declared maximum value, depending on lamp types.
Dimensions
Length 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
360
30
21
350
2
430
30
21
420
d
c
a
b
d
Ballast
EL1 x iDim
EL2 x iDim
EL3 x iDim
EL4 x iDim
Delivery information
Transportation package
Unit package
Minimum Plastic
EUR pallet
Pallet
Pallet
delivery binding
1200 x 800
weight
height
amount
strip
(pcs.)
(kg)
(cm)
10
980
300
40
840
325
43
10
840
325
43
10
840
325
43
10
29
EL-iDim
Digital DALI electronic ballasts for T8 fluorescent lamps
36 W 220-240 V, 50-60 Hz
A1 BAT
Lamp
type
Wattage
No. of
lamps
Ballast
EEI
Dimensions Connection
Weight
Circuit
power
Mains
current
Lamp
power
(p.33)
(g)
T8
36
EL1x36iDim
A1 BAT
250
(W)
(A)
(W)
35.5
0.17-0.15
32
36
EL2x36iDim
A1 BAT
330
70.5
0.32-0.30
32
Note: See pages 33- 35 for connection diagrams and additional characteristics.
Home
Prev
Next
Dimensions
360
30
21
350
430
30
21
420
a
b
d
Delivery information
Ballast
Unit package
Minimum
delivery
amount
EL1 x iDim
EL2 x iDim
10
10
Plastic
binding
strip
Transportation package
EUR pallet
1200 x 800
Pallet
weight
Pallet
height
(pcs.)
980
840
(kg)
300
325
(cm)
40
43
Helvar | Data is subject to change without notice. More information at: www.helvar.com
EL-iDim
Digital DALI electronic ballasts for compact fluorescent lamps
24 - 80 W 220-240 V, 50-60 Hz
A1 BAT
Lamp
type
TC-L
Wattage
No. of
lamps
Ballast
EEI
Dimensions Connection
Weight
Circuit
power
Mains
current
Lamp
power
(p.33)
(g)
(W)
(A)
(W)
24
24
1
2
EL1x24iDim
EL2x24iDim
A1 BAT
A1 BAT
1
2
1
2
250
330
25.5
50.5
0.12-0.10
0.23-0.21
22.5
22.5
26
EL1x14-35iDim *
A1 BAT
250
29.3
0.13
26
26
28
28
36
36
55
55
80
80
2
1
2
1
2
1
2
1
2
EL2x14-35iDim *
EL1x14-35iDim *
EL2x14-35iDim *
EL1x36iDim
EL2x36iDim
EL1x55iDim
EL2x55iDim
EL1x80iDim
EL2x80iDim
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
2
1
2
1
2
1
2
1
2
2
1
2
1
2
1
2
1
2
330
250
330
250
330
250
330
250
365
56
29.3
56
35.5
70.5
59.5
119.5
86
170
0.25
0.13
0.25
0.17-0.15
0.32-0.30
0.27-0.25
0.55-0.50
0.39-0.36
0.78-0.70
26
26
26
32
32
55
55
80
80
Home
Prev
Next
Note: See pages 33- 35 for connection diagrams and additional characteristics.
*) Dimming range 3-100 %
Dimensions
360
30
21
350
430
30
21
420
a
b
d
Delivery information
Ballast
Unit package
Minimum
delivery
amount
EL1 x iDim
EL2 x iDim
10
10
Plastic
binding
strip
Transportation package
EUR pallet
1200 x 800
Pallet
weight
Pallet
height
(pcs.)
980
840
(kg)
300
325
(cm)
40
43
31
EL-iDim-c
Digital DALI electronic ballasts for compact fluorescent lamps
18 - 42 W 220-240 V, 50-60 Hz
A1 BAT
Lamp
type
TC-L/
TC-F
T5c
TC-DE/
TC-TE
Wattage
No. of
lamps
18
18
24
24
22
40
18
18
26
26
26
32
32
42
42
57
1
2
1
2
1
1
1
2
1
2
2
1
2
1
2
1
Ballast
EEI
EL1/2x18/24iDim-c
EL1/2x18/24iDim-c
EL1/2x18/24iDim-c
EL1/2x18/24iDim-c
EL1/2x18/24iDim-c
EL1/2x18/24iDim-c
EL1/2x18iDim-c
EL1/2x18iDim-c
EL1/2x26-42iDim-c
EL1/2x26-42iDim-c
EL2x26-42iDim-c
EL1/2x26-42iDim-c
EL2x26-42iDim-c
EL1/2x26-42iDim-c
EL2x26-42iDim-c
EL1/2x26-42iDim-c 1)2)
Dimensions Connection
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
A1 BAT
123x79x28
123x79x28
123x79x28
123x79x28
123x79x28
123x79x28
123x79x28
123x79x28
123x79x28
123x79x28
123x79x28
123x79x28
123x79x28
123x79x28
123x79x28
123x79x28
(p.33)
5
6
5
6
5
5
5
6
5
6
7
5
7
5
7
5
Weight
Circuit
power
Mains
current
Lamp
power
(g)
155
155
155
155
155
155
155
155
155
155
176
155
176
155
176
155
(W)
18
35.5
26
50
26
44.5
20
38
28
56
56
35
70.5
46
93
61
(A)
0.09
0.16
0.12
0.23
0.12
0.20
0.09
0.17
0.13
0.25
0.25
0.16
0.32
0.2
0.42
0.27
(W)
16
16
22
22
22
40
16.5
16.5
23
23.5
25
31
32
41.5
43
56
Note: See pages 33- 35 for connection diagrams and additional characteristics.
1) Tested and recommended by Helvar, not ENEC approved
2) UIN > 220 V, Ta > 18 C
Dimensions
Delivery information
Ballast
EL-iDim-c
Unit package
Transportation package
Minimum
delivery
amount
Carton
Box
Pallet
820 x 1280
Pallet
weight
Pallet
height
10
40
(pcs.)
800
(kg)
148
(cm)
48
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
Connection diagrams
EL-iDim
NOTE: All wiring to the connectors marked with a red dot (hot wires) should be as short as possible.
SWITCHCONTROL
SWITCHCONTROL
2
6
SWITCHCONTROL
Home
SWITCHCONTROL
Prev
Next
SWITCHCONTROL
SWITCHCONTROL
SWITCHCONTROL
EL1x ...iDim
EL2x ...iDim
EL3x ...iDim
EL4x ...iDim
EL1/2x...iDim-c
EL1/2x...iDim-c
EL2x...iDim-c
33
Characteristics
EL-iDim
EL-iDim-c
Max.temperature at tc point
75 C 3)
75 C
+10+50 C 1) 5) 6)
+10+50 C 5)
-40+80 C
no condensation
> 50 000
198-264 VAC
-40+80 C
no condensation
> 50 000
198-264 VAC
176-280 VDC
320 VAC, 1h
N/A
176-280 VDC
320 VAC, 1h
> 0.5 7)
~1
yes
0.96
< 0.4 mA
400 V
~1
yes
0.96
< 0.4 mA
400 V
50 000 h, at tc
1.0 s
Type of starting
50 000 h, at tc
2)4)
1 m / 1 m (hot / cold) 4)
Home
1.0 s 8)
Preheat (warm start)
Prev
1) To ensure stable operation of TC-L lamps in ambient temperatures below 18 C it is not recommended
to dim the light level below 3 %
2) For TC-L lamps 1 m / 2 m (hot/cold lamp wires)
3) For EL 3x14iDim, tc = 65 OC
4) Minimise lamp wire length variations in order to avoid imbalance in light output.
5) When using EL3x14iDim, EL4x14iDim and EL1/2x18/24iDim-c ballasts in ambient temperatures below
15 OC it is not
recommended to dim the light level below 10 % to ensure stable lamp operation.
6) For EL2x80iDim, it is not recommended to dim the light below 5 % in temperatures below 15 OC
7) EL2x26-42iDim-c; EBLF > 0,3
8) EL1/2x18/24iDim-c ignition time = 1.4 s
O
Next
Standards
EL-iDim
EL-iDim-c
* EN 60081 for T5 & T8 fluorescent lamps, EN 60901 for compact fluorescent lamps
34
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Connection
A) 0-25 m
Suitable switch:
Automatic return type
Mains rated
Connection:
EL-iDim ballasts:
To the DALI input
Wire length:
25 m maximum. diagram A
25 - 200 m, use a capacitor (1 F, 275 V) diagram B
Ballasts per switch:
50 (observe above)
Ensure all ballasts and associated switches are connected to the same mains
phase
Operation:
Short push of the switch ( < 0.4 second)
Switch off:
Switch on:
Short push of the switch ( < 0.4 second)
EL-iDim ballasts will switch on to the last set level
Dimming:
Long push of the switch ( > 0.5 second)
If lamps are off, the ballast dims up from minimum
If lamps are on, the ballast dims in the opposite direction to previously
The first dimming direction is dimming down
Correction of out of sequence operation:
Switch the mains supply off and on, or
Long push (until all lamps are on), then a short push (all lamps off), then switch
on
B) 25-200 m
Home
Prev
Next
1F
Compatibility:
Some ballasts manufacturers have functionality similar to Helvar SwitchControl. These methods are NOT COMPATIBLE with each other.
35
Home
Prev
Next
36
Helvar | Data is subject to change without notice. More information at: www.helvar.com
freedom in lighting
37
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Prev
Next
EL-sc
Controllable (1-10 V) electronic ballasts for T5 fluorescent lamps
14-80 W 220-240 V, 50-60 Hz
A1
Lamp
type
T5
Wattage
No. of
lamps
14
14
14
21
21
24
24
28
28
35
35
39
39
49
49
54
54
80
1
2
4
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
Ballast
EEI
EL1x14sc
EL2x14sc
EL4x14sc 2)
EL1x21sc
EL2x21sc
EL1x24sc
EL2x24sc
EL1x28sc
EL2x28sc
EL1x35sc
EL2x35sc
EL1x39sc
EL2x39sc
EL1x49sc
EL2x49sc
EL1x54sc
EL2x54sc
EL1x80sc
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
Dimensions Connection
1
2
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
(p.42)
1
2
3
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
Weight
Circuit
power
Mains
current
Lamp
power
(g)
270
340
340
270
340
270
340
270
340
270
340
270
340
270
340
270
340
270
(W)
17
31
62
24
46
26
50
31
64
39
78
42
83
55
106
61
118
88
(A)
0.08-0.07
0.15-0.14
0.29-0.27
0.11-0.10
0.22-0.20
0.13-0.12
0.24-0.20
0.15-0.14
0.30-0.28
0.18-0.17
0.36-0.34
0.20-0.18
0.40-0.36
0.25-0.23
0.50-0.46
0.28-0.26
0.53-0.49
0.41-0.38
(W)
13.7
13.7
13.7
20.7
20.7
22.5
22.5
27.8
27.8
34.7
34.7
38
38
49.3
49.3
53.8
53.8
80
Note: See pages 42-43 for connection diagrams and additional characteristics.
1) Simultaneous lighting control by Switch-Control and Analogue control
2) Dimming range 3-100 % for EL 4x14sc
Dimensions
Length 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
360
30
21
350
2
430
30
21
420
c
a
b
d
Ballast
EL1 x sc
EL2 x sc
EL4 x sc
38
Delivery information
Transportation package
Unit package
Minimum Plastic
EUR pallet
Pallet
Pallet
delivery binding
1200 x 800
weight
height
amount
strip
(pcs.)
(kg)
(cm)
10
10
10
980
840
840
300
325
325
40
43
43
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
EL-sc
Controllable (1-10 V) electronic ballasts for T5-eco fluorescent lamps
14-80 W 220-240 V, 50-60 Hz
A1
Lamp
type
T5
eco
Wattage
No. of
lamps
14 eco
14 eco
14 eco
21 eco
21 eco
24 eco
24 eco
28 eco
28 eco
35 eco
35 eco
49 eco
49 eco
54 eco
54 eco
80 eco
1
2
4
1
2
1
2
1
2
1
2
1
2
1
2
1
Ballast
EEI
EL1x14sc
EL2x14sc
EL4x14sc 2)
EL1x21sc
EL2x21sc
EL1x24sc
EL2x24sc
EL1x28sc
EL2x28sc
EL1x35sc
EL2x35sc
EL1x49sc
EL2x49sc
EL1x54sc
EL2x54sc
EL1x80sc
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
A1
1
2
2
1
2
1
2
1
2
1
2
1
2
1
2
1
(g)
270
340
340
270
340
270
340
270
340
270
340
270
340
270
340
270
Circuit
power
Mains
current
Lamp
power 3)
(W)
17
31
62
24
46
26
50
31
64
39
78
55
106
61
118
88
(A)
0.08-0.07
0.15-0.14
0.29-0.27
0.11-0.10
0.22-0.20
0.13-0.12
0.24-0.20
0.15-0.14
0.30-0.28
0.18-0.17
0.36-0.34
0.25-0.23
0.50-0.46
0.28-0.26
0.53-0.49
0.41-0.38
(W)
13.7
13.7
13.7
20.7
20.7
22.5
22.5
27.8
27.8
34.7
34.7
49.3
49.3
53.8
53.8
80
Home
Prev
Next
Note: See pages 42-43 for connection diagrams and additional characteristics.
1) Simultaneous lighting control by Switch-Control and Analogue control
2) Dimming range 3-100 % for EL 4x14sc
3) Powercontrolled products, no energy saving when ecolamps are used. Lamps are running over powered.
Dimensions
Length 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
360
30
21
350
2
430
30
21
420
c
a
b
d
Ballast
EL1 x sc
EL2 x sc
EL4 x sc
Delivery information
Transportation package
Unit package
Minimum Plastic
EUR pallet
Pallet
Pallet
delivery binding
1200 x 800
weight
height
amount
strip
(pcs.)
(kg)
(cm)
10
10
10
980
840
840
300
325
325
40
43
43
Helvar | Data is subject to change without notice. More information at: www.helvar.com
39
EL-sc
Controllable (1-10 V) electronic ballasts for T8 fluorescent lamps
18-70 W 220-240 V, 50-60 Hz
A1
Lamp
type
T8
Wattage
No. of
lamps
Ballast
EEI
18
Dimensions Connection
Weight
Circuit
power
Mains
current
Lamp
power
EL1x18sc
A1
(p.42)
(g)
270
(W)
(A)
(W)
19
0.09-0.08
16
18
EL2x18sc
A1
340
37
0.18-0.15
16
18
EL4x18sc 2)
A1
340
72
0.33-0.30
16
36
EL1x36sc
A1
270
37
0.17-0.16
32
36
EL2x36sc
A1
340
71
0.33-0.30
32
58
EL1x58sc
A1
270
55
0.27-0.26
50
58
EL2x58sc
A1
340
108
0.50-0.46
50
70
EL1x70sc
A1
270
65
0.31-0.27
60
Note: See pages 42-43 for connection diagrams and additional characteristics.
1) Simultaneous lighting control by Switch-Control and Analogue control
2) Dimming range 3-100 % for 4x18sc
Dimensions
360
30
21
350
430
30
21
420
a
b
d
Ballast
EL1 x sc
EL2 x sc
EL4 x sc
40
Delivery information
Transportation package
Unit package
Minimum Plastic
EUR pallet
Pallet
Pallet
delivery binding
1200 x 800
weight
height
amount
strip
(pcs.)
(kg)
(cm)
10
10
10
980
840
840
300
325
325
40
43
43
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
Home
Operation:
Switch off:
Short push of the switch (<0.4 second).
Switch on:
Short push of the switch (<0.4 second).
Re-strike within 3 seconds of switch off is prevented to ensure
optimal lamp warm start.
EL-sc ballasts will switch on to the analogue control set level.
Dimming:
Long push of the switch (>0.5 second).
If lamps are off, the ballast dims up from minimum.
If lamps are on, the ballast dims in the opposite direction to
previously. The first dimming direction is dimming down.
Prev
Next
Connection
Helvar | Data is subject to change without notice. More information at: www.helvar.com
43
Connection diagrams
EL-sc
NOTE: All wiring to the connectors marked with a red dot (hot wires) should be as short as possible.
SWITCH-CONTROL*
SWITCH-CONTROL*
1-10 VDC
control
< 1mA
1-10 VDC
control
< 1mA
3
SWITCH-CONTROL*
1-10 VDC
control
< 1mA
EL1x ...sc
EL2x ...sc
EL4x ...sc
Prev
Characteristics
EL-sc
Max.temperature at tc point
80 C
+10+50 C 1)
-40+80 C
no condensation
Next
> 50 000
AC Range
DC range (starting voltage >190VDC)
198-264 VAC
176-280 VDC
320 VAC, 1 h
0.98
< 0.4 mA
400 V
50 000 h, at 70 C tc
<1.3 s
1) To ensure stable operation of TC-L lamps in ambient temperatures below 18OC it is not recommended to dim the light level below 3 %
2) For TC-L lamps 1 m/2 m (hot/cold lamp wires)
Standards
EL-sc
* EN 60081 for T5 & T8 fluorescent lamps, EN 60901 for compact fluorescent lamps
42
Home
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Operation:
Switch off:
Short push of the switch (<0.4 second).
Switch on:
Short push of the switch (<0.4 second).
Re-strike within 3 seconds of switch off is prevented to ensure
optimal lamp warm start.
EL-sc ballasts will switch on to the analogue control set level.
Dimming:
Long push of the switch (>0.5 second).
If lamps are off, the ballast dims up from minimum.
If lamps are on, the ballast dims in the opposite direction to
previously.
The first dimming direction is dimming up.
Prev
Next
Connection
Helvar | Data is subject to change without notice. More information at: www.helvar.com
43
freedom in lighting
44
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
Prev
Next
Helvar | Data is subject to change without notice. More information at: www.helvar.com
45
EL-ngn5
Electronic ballasts for T5 fluorescent lamps
14-80 W 220-240 V, 50-60 Hz
A2 BAT
Lamp
type
T5
Wattage
No. of
lamps
14
14
14
14
14
21
21
24
24
24
24
28
28
35
35
39
39
49
49
54
54
80
80
1
2
3
4
4
1
2
1
2
3
4
1
2
1
2
1
2
1
2
1
2
1
2
Ballast
EEI
EL1x14-35ngn5
EL2x14-35ngn5
EL3/4x14ngn5
EL3/4x14ngn5
EL4x14ngn5
EL1x14-35ngn5
EL2x14-35ngn5
EL1x24ngn5
EL2x24ngn5
EL3/4x24ngn5
EL3/4x24ngn5
EL1x14-35ngn5
EL2x14-35ngn5
EL1x14-35ngn5
EL2x14-35ngn5
EL1x39/36ngn5
EL2x39/36ngn5
EL1x49ngn5
EL2x49ngn5
EL1x54ngn5
EL2x54ngn5
EL1x80ngn5
EL2x80ngn5
A2 BAT
A2 BAT
A2
A2
A2
A2 BAT
A2 BAT
A2
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
Dimensions Connection
1
2
2
2
2
1
2
1
2
2
2
1
2
1
2
1
2
1
2
1
2
2
3
(p.62)
1
14
7
8
8
1
14
1
9
7
8
1
14
1
14
1
9
1
14
1
9
1
14
Weight
Circuit
power
Mains
current
Lamp
power
(g)
127
204
204
204
190
127
204
130
193
208
208
127
204
127
204
130
195
130
211
130
206
192
300
(W)
15.5
31
46
62
63
23
45
25
49
73
97
30
60
38
75
42
81
55
105
58
115
86
170
(A)
0.08-0.06
0.16-0.15
0.22-0.19
0.29-0.26
0.30-0.26
0.12-0.10
0.22-0.19
0.12-0.11
0.24-0.21
0.34-0.30
0.44-0.40
0.15-0.12
0.29-0.25
0.18-0.16
0.35-0.31
0.19-0.18
0.36-0.32
0.25-0.23
0.50-0.45
0.26-0.24
0.53-0.48
0.42-0.36
0.80-0.73
(W)
13.7
13.7
13.7
13.7
13.7
20.7
20.7
22.5
22.5
22.5
22.5
27.8
27.8
34.7
34.7
38
38
49.3
49.3
53.8
53.8
80
80
Note: See pages 62-64 for connection diagrams and additional characteristics.
Dimensions
Lenght 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
190
30
21
180
2
280
30
21
270
360
30
21
350
d
c
a
b
d
Delivery information
Ballast
Unit package
Transportation package
Pallet
Minimum Plastic One-way pallet Pallet
1200 x 820
weight
height
delivery binding
strip
amount
(pcs.)
(kg)
(cm)
EL1 x ngn5
10
2000
260-300
48
2000
400-450
56
EL2 x ngn5 & EL3/4 x ngn5
10
1500
400-420
56
EL2x55ngn5 & EL2x80ngn5
10
46
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
EL-ngn5
Electronic ballasts for T5-eco fluorescent lamps
14-80 W 220-240 V, 50-60 Hz
A2 BAT
Lamp type
T5
eco
14 eco
14 eco
14 eco
14 eco
21 eco
21 eco
24 eco
24 eco
24 eco
24 eco
28 eco
28 eco
35 eco
35 eco
39 eco
39 eco
49 eco
49 eco
54 eco
54 eco
80 eco
80 eco
No. of
lamps
1
2
3
4
1
2
1
2
3
4
1
2
1
2
1
2
1
2
1
2
1
2
Ballast
EEI
EL1x14-35ngn5
EL2x14-35ngn5
EL3/4x14ngn5
EL3/4x14ngn5
EL1x14-35ngn5
EL2x14-35ngn5
EL1x24ngn5
EL2x24ngn5
EL3/4x24ngn5
EL3/4x24ngn5
EL1x14-35ngn5
EL2x14-35ngn5
EL1x14-35ngn5
EL2x14-35ngn5
EL1x39/36ngn5
EL2x39/36ngn5
EL1x49ngn5
EL2x49ngn5
EL1x54ngn5
EL2x54ngn5
EL1x80ngn5
EL2x80ngn5
A2 BAT
A2 BAT
A2
A2
A2 BAT
A2 BAT
A2
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
Dimensions Connection
1
2
2
2
1
2
1
2
2
2
1
2
1
2
1
2
1
2
1
2
2
3
(p.62)
1
14
7
8
1
14
1
9
7
8
1
14
1
14
1
9
1
14
1
9
1
14
Weight
Circuit
power 1)
Mains
current 1)
Lamp
power 1)
(g)
127
204
204
204
127
204
130
193
208
208
127
204
127
204
130
195
130
211
130
206
192
300
(W)
15.5
31
46
62
23
45
25
49
73
97
30
60
38
75
42
81
55
105
58
115
86
170
(A)
0.08-0.06
0.16-0.15
0.22-0.19
0.29-0.26
0.12-0.10
0.22-0.19
0.12-0.11
0.24-0.21
0.34-0.30
0.44-0.40
0.15-0.12
0.29-0.25
0.18-0.16
0.35-0.31
0.19-0.18
0.36-0.32
0.25-0.23
0.50-0.45
0.26-0.24
0.53-0.48
0.42-0.36
0.80-0.73
(W)
13.7
13.7
13.7
13.7
20.7
20.7
22.5
22.5
22.5
22.5
27.8
27.8
34.7
34.7
38
38
49.3
49.3
53.8
53.8
80
80
Home
Prev
Next
Note: See pages 62-64 for connection diagrams and additional characteristics.
1) Maximum 10 % energy saving achieved from declared maximum value depending on difference in lamps from various manufacturers.
Dimensions
Lenght 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
190
30
21
180
2
280
30
21
270
360
30
21
350
d
c
a
b
d
Delivery information
Ballast
Unit package
Transportation package
Pallet
Minimum Plastic One-way pallet Pallet
1200 x 820
weight
height
delivery binding
strip
amount
(pcs.)
(kg)
(cm)
EL1 x ngn5
10
2000
260-300
48
2000
400-450
56
EL2 x ngn5 & EL3/4 x ngn5
10
1500
400-420
56
EL2x55ngn5 & EL2x80ngn5
10
Helvar | Data is subject to change without notice. More information at: www.helvar.com
47
EL-s
Electronic ballasts for T5 fluorescent lamps
14-80 W 220-240 V, 50-60 Hz
Only 21 mm high
Optimal lamp operation
Wide operational ambient temperature range
Standard & sidemount possibilities
Low power losses
Silent operation
Stabilised flickerfree light
High power factor
A2
Lamp
type
T5
Wattage
No. of
lamps
14
14
14
14
21
21
24
24
28
28
35
35
39
39
49
49
54
54
80
1
2
3
4
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
Ballast
EEI
Dimensions
Connection
Weight
Circuit
power
Mains
current
Lamp
power
EL1x14-35s
EL2x14-35s
EL3/4x14s
EL3/4x14s
EL1x14-35s
EL2x14-35s
EL1x24s
EL2x24s
EL1x14-35s
EL2x14-35s
EL1x14-35s
EL2x14-35s
EL1x39/36s
EL2x39/36s
EL1x49s
EL2x49s
EL1x54s
EL2x54s
EL1x80s
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
1
2
2
2
1
2
1
2
1
2
1
2
1
2
1
2
1
2
1
(p.62)
1
3
5
6
1
3
1
2
1
3
1
3
1
2
1
3
1
2
1
(g)
175
250
250
250
175
250
190
230
175
250
175
250
190
245
190
260
200
260
200
(W)
15.5
31
46
62
23
45
25
49
30
60
38
75
42
81
52.5
104
58
114.5
85
(A)
0.08-0.07
0.15-0.13
0.22-0.19
0.29-0.26
0.12-0.10
0.22-0.19
0.12-0.11
0.24-0.21
0.15-0.12
0.29-0.25
0.18-0.16
0.35-0.31
0.19-0.18
0.36-0.32
0.25-0.23
0.50-0.45
0.26-0.24
0.53-0.48
0.40-0.36
(W)
13.7
13.7
13.7
13.7
20.7
20.7
22,5
22.5
27.8
27.8
34.7
34.7
38
38
49.3
49.3
53.8
53.8
80
Note: See pages 62-63 for connection diagrams and additional characteristics.
Dimensions
Length 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
280
30
21
270
2
360
30
21
350
d
c
a
b
d
Delivery information
Ballast
Transportation package
Unit package
Pallet
Minimum Plastic One-way pallet Pallet
1200 x 820
weight
height
delivery binding
strip
amount
(pcs.)
(kg)
(cm)
EL1 x s
10
2000
350 - 420
57
1500
395
57
EL2 x s
10
1500
390
57
EL3/4 x s
10
48
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
EL-s
Electronic ballasts for T5-eco fluorescent lamps
14-80 W 220-240 V, 50-60 Hz
Only 21 mm high
Optimal lamp operation
Wide operational ambient temperature range
Standard & sidemount possibilities
Low power losses
Silent operation
Stabilised flickerfree light
High power factor
A2
Lamp type
T5
eco
No. of
lamps
14 eco
14 eco
14 eco
14 eco
21 eco
21 eco
24 eco
24 eco
28 eco
28 eco
35 eco
35 eco
49 eco
49 eco
54 eco
54 eco
80 eco
1
2
3
4
1
2
1
2
1
2
1
2
1
2
1
2
1
Ballast
EEI
Dimensions
Connection
Weight
Circuit
power 1)
Mains
current 1)
Lamp
power 1)
EL1x14-35s
EL2x14-35s
EL3/4x14s
EL3/4x14s
EL1x14-35s
EL2x14-35s
EL1x24s
EL2x24s
EL1x14-35s
EL2x14-35s
EL1x14-35s
EL2x14-35s
EL1x49s
EL2x49s
EL1x54s
EL2x54s
EL1x80s
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
1
2
2
2
1
2
1
2
1
2
1
2
1
2
1
2
1
(p.62)
1
3
5
6
1
3
1
2
1
3
1
3
1
3
1
2
1
(g)
175
250
250
250
175
250
190
230
175
250
175
250
190
260
200
260
200
(W)
13-15
29.2-30.3
38.8-43
52.3-57.4
19.5
39.5
21.6
43.6
28.6
57.4
35.3-37.4
70.8-72.7
46.8-48
94-100.3
52.2-54
105.4-108.5
74.8-80
(A)
0.08-0.06
0.13-0.12
0.19-0.17
0.25-0.23
0.09
0.17
0.10
0.19
0.12
0.25
0.16-0.15
0.31-0.30
0.21-0.20
0.43-0.40
0.24-0.22
0.46-0.45
0.34-0.32
(W)
11.3-13.4
11.3-13.4
12.1-13.7
12.1-13.7
17.7
17.7
19.3
19.3
25.8
26.2
32.5-34.3
32.5-34.3
43.4-47.4
43.4-47.4
48.3-52
48.3-52
70.5-75.6
Home
Prev
Next
Note: See pages 62-63 for connection diagrams and additional characteristics.
1) Depending on difference in lamps from various manufacturers
Dimensions
Length 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
280
30
21
270
2
360
30
21
350
d
c
a
b
d
Delivery information
Ballast
Transportation package
Unit package
Pallet
Minimum Plastic One-way pallet Pallet
1200 x 820
weight
height
delivery binding
strip
amount
(pcs.)
(kg)
(cm)
EL1 x s
10
2000
350 - 420
57
1500
395
57
EL2 x s
10
1500
390
57
EL3/4 x s
10
Helvar | Data is subject to change without notice. More information at: www.helvar.com
49
EL-su
Electronic ballasts for T5 fluorescent lamps
Only 21 mm high
Optimal lamp operation
Wide operational ambient temperature range
Standard & sidemount possibilities
With terminals for both manual and automatic wiring (IDC & push-in)
Low power losses
Silent operation
Stabilized flickerfree light
High power factor
A2
Lamp
type
T5
Wattage
No. of
lamps
14
14
14
14
21
21
24
24
28
28
35
35
49
49
80
1
2
3
4
1
2
3
4
1
2
1
2
1
2
2
Ballast
EL1x14-35s-u
EL2x14-35s-u
EL3/4x14s-u
EL3/4x14s-u
EL1x14-35s-u
EL2x14-35s-u
EL3/4x24s-u
EL3/4x24s-u
EL1x14-35s-u
EL2x14-35s-u
EL1x14-35s-u
EL2x14-35s-u
EL1x49s-u
EL2x49s-u
EL2x80s-u
EEI
Dimensions Connection
A2
A2
A2
A2
A2
A2
A2 BAT
A2 BAT
A2
A2
A2
A2
A2
A2
A2 BAT
1
2
1
1
1
2
1
1
1
2
1
2
1
2
2
(p.62)
1
4
7
8
1
4
7
8
1
4
1
4
1
4
4
Weight
Circuit
power
Mains
current
Lamp
power
(g)
175
250
210
210
175
250
215
215
175
250
175
250
190
260
305
(W)
15.5
31
46
62
23
45
73
97
30
60
38
75
52.5
104
170
(A)
0.08-0.07
0.15-0.13
0.22-0.19
0.29-0.26
0.12-0.10
0.22-0.19
0.34-0.30
0.44-0.40
0.15-0.12
0.29-0.25
0.18-0.16
0.35-0.31
0.25-0.23
0.50-0.45
0.80-0.73
(W)
13.7
13.7
13.7
13.7
20.7
20.7
22.5
22.5
27.8
27.8
34.7
34.7
49.3
49.3
80
Note: See pages 62-63 for connection diagrams and additional characteristics.
Dimensions
Length 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
280
30
21
270
2
360
30
21
350
d
c
a
b
d
Delivery information
Ballast
Transportation package
Unit package
Pallet
Minimum Plastic One-way pallet Pallet
1200 x 820
weight
height
delivery binding
strip
amount
(pcs.)
(kg)
(cm)
EL1 x s-u
10
2000
350 - 420
57
1500
395
57
EL2 x s-u
10
1500
390
57
EL3/4 x s-u
10
50
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
EL-su
Electronic ballasts for T5-eco fluorescent lamps
Only 21 mm high
Optimal lamp operation
Wide operational ambient temperature range
Standard & sidemount possibilities
With terminals for both manual and automatic wiring (IDC & push-in)
Low power losses
Silent operation
Stabilized flickerfree light
High power factor
A2
Lamp type
T5
eco
No. of
lamps
14 eco
14 eco
14 eco
14 eco
21 eco
21 eco
24 eco
24 eco
28 eco
28 eco
35 eco
35 eco
49 eco
49 eco
80 eco
1
2
3
4
1
2
3
4
1
2
1
2
1
2
2
Ballast
EL1x14-35s-u
EL2x14-35s-u
EL3/4x14s-u
EL3/4x14s-u
EL1x14-35s-u
EL2x14-35s-u
EL3/4x24s-u
EL3/4x24s-u
EL1x14-35s-u
EL2x14-35s-u
EL1x14-35s-u
EL2x14-35s-u
EL1x49s-u
EL2x49s-u
EL2x80s-u
EEI
Dimensions
Connection
Weight
Circuit
power 1)
Mains
current 1)
Lamp
power 1)
A2
A2
A2
A2
A2
A2
A2 BAT
A2 BAT
A2
A2
A2
A2
A2
A2
A2 BAT
1
2
1
1
1
2
1
1
1
2
1
2
1
2
2
(p.62)
1
4
7
8
1
4
7
8
1
4
1
4
1
4
4
(g)
175
250
210
210
175
250
215
215
175
250
175
250
190
260
305
(W)
13-15
29.2-30.3
38.8-43
52.3-57.4
19.5
39.5
64.3
85
28.6
57.4
35.3-37.4
70.8-72.7
46.8-48
94-100.3
151.8-161
(A)
0.08-0.06
0.13-0.12
0.19-0.17
0.25-0.23
0.09
0.17
0.28
0.37
0.12
0.25
0.16-0.15
0.31-0.30
0.21-0.20
0.43-0.40
0.70-0.65
(W)
11.3-13.4
11.3-13.4
12.1-13.7
12.1-13.7
17.7
17.7
19.4
19.75
25.8
26.2
32.5-34.3
32.5-34.3
43.4-47.4
43.4-47.4
71.2-76.2
Home
Prev
Next
Dimensions
Length 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
280
30
21
270
2
360
30
21
350
d
c
a
b
d
Delivery information
Ballast
Transportation package
Unit package
Pallet
Minimum Plastic One-way pallet Pallet
1200 x 820
weight
height
delivery binding
strip
amount
(pcs.)
(kg)
(cm)
EL1 x s-u
10
2000
350 - 420
57
1500
395
57
EL2 x s-u
10
1500
390
57
EL3/4 x s-u
10
Helvar | Data is subject to change without notice. More information at: www.helvar.com
51
EL-ngn
Electronic ballasts for T8 fluorescent lamps
18-58 W 220-240 V, 50-60 Hz
Energy saving
Warm Start according to lamp standards
Flickerless light
Covers EMC requirements
Low harmonics
Low power losses
Stabilized output
A2
Lamp
type
T8
Wattage
No. of
lamps
Ballast
EEI
Dimensions
18
EL1x18ngn
A2
18
EL2x18ngn
A2
18
EL3/4x18ngn
18
18
Connection
Weight
Circuit
power
Mains
current
Lamp
power
(p.62)
(g)
190
(W)
(A)
(W)
19
0.09-0.08
16
200
37
0.16-0.15
16
A2
210
52
0.25-0.23
16
EL3/4x18ngn
A2
210
69
0.33-0.30
16
EL4x18ngn
A2
10
200
72
0.33-0.30
16
36
EL1x36ngn
A2
191
36
0.16-0.15
32
36
EL2x36ngn
A2
205
71
0.32-0.29
32
58
EL1x58ngn
A2
193
55
0.26-0.23
50
58
EL2x58ngn
A2
218
108
0.50-0.45
50
Home
Prev
Next
Note: See pages 62-63 for connection diagrams and additional characteristics.
Dimensions
drawing
Length 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
a
280
30
28
270
2
b
280
30
21
270
Delivery information
Ballast
Unit package
Transportation package
Pallet
Minimum Plastic One-way pallet Pallet
1200 x 820
weight
height
delivery binding
strip
amount
(pcs.)
(kg)
(cm)
EL1 x ngn
10
1600
330
60
1600
320-360
60
EL2 x ngn
10
1500
385
57
EL3/4x18ngn
10
1600
370
60
EL4 x ngn
10
52
c
a
b
d
Helvar | Data is subject to change without notice. More information at: www.helvar.com
d
c
a
b
d
EL-s, EL-su
Electronic ballasts for T8 fluorescent lamps
18-70 W 220-240 V, 50-60 Hz
Only 21 mm high
Optimal lamp operation
Wide operational ambient temperature range
Standard & sidemount possibilities
Optional terminals for automatic wiring
Low power losses
Silent operation
Stabilized flickerfree light
High power factor
A2
Lamp
type
T8
Wattage
No. of
lamps
Ballast
EEI
Dimensions
Connection
Weight
Circuit
power
Mains
current
Lamp
power
18
EL1x18s
A2
(p.62)
1
(g)
190
(W)
18
(A)
0.09-0.08
(W)
16
18
EL2x18s
A2
230
34.5
0.16-0.15
16
18
EL3/4x18s
A2
250
52
0.25-0.23
16
18
EL3/4x18s-u 2)
A2
210
52
0.25-0.23
16
18
EL3/4x18s
A2
250
69
0.33-0.30
16
18
EL3/4x18s-u 2)
A2
210
69
0.33-0.30
16
32
EL1x49s
1)
A2
190
34.5
0.15
32
32
EL2x49s 1)
A2
260
72
0.31
32
36
EL1x36/40/18s
A2
190
35
0.16-0.15
32
36
EL1x36/40s-u
A2
190
35
0.16-0.15
32
36
EL2x36/40s
A2
245
69
0.32-0.29
32
36
EL2x36/40s-u 2)
A2
245
69
0.32-0.29
32
58
EL1x58s
A2
200
54
0.26-0.23
50
58
EL1x58s-u 2)
A2
200
54
0.26-0.23
50
58
EL2x58s
A2
260
106.5
0.50-0.45
50
58
EL2x58s-u
A2
260
106.5
0.50-0.45
50
70
EL1x70s
A2
200
64.5
0.30-0.28
60
70
EL2x70s
A2
260
128
0.59-0.54
60
2)
2)
Home
Prev
Next
Note: See pages 62-63 for connection diagrams and additional characteristics.
1) Tested and recommended by Helvar, not ENEC approved
2) With terminals for both manual and automatic wiring (IDC & push-in)
Dimensions
drawing
Length 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
a
280
30
21
270
2
a
360
30
21
350
3
b
280
30
21
270
4
b
360
30
21
350
Delivery information
Ballast
Unit package
Transportation package
Pallet
Minimum Plastic One-way pallet Pallet
1200 x 820
weight
height
delivery binding
strip
amount
(pcs.)
(kg)
(cm)
EL1 x s
10
2000
350 - 420
57
1500
395
57
EL2 x s
10
1500
385
57
EL3/4 x s
10
d
c
a
b
d
Helvar | Data is subject to change without notice. More information at: www.helvar.com
d
c
a
b
d
53
EL-es
Electronic ballasts for T8 fluorescent lamps
Energy saver
A2
Lamp
type
T8
Wattage
No. of
lamps
Ballast
EEI
Connection
Weight
Circuit power
Mains current
Lamp power
(p.62)
(g)
(W)
(A)
(W)
18
EL4x18es
A2
10
190
72
0.30-0.33
16
36
EL2x36es
A2
190
71
0.32-0.29
32
58
EL2x58es
A2
200
108
0.50-0.45
50
Home
Prev
Note: See pages 62-63 for connection diagrams and additional characteristics.
Next
Dimensions
drawing
Length 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
a
280
30
28
270
c
a
b
d
Delivery information
Ballast
Unit package
Transportation package
Pallet
Minimum Plastic One-way pallet Pallet
1200 x 820
weight
height
delivery binding
strip
amount
(pcs.)
(kg)
(cm)
EL4x18es
10
1600
330
60
1600
330
60
EL2x36es
10
1600
350
60
EL2x58es
10
54
Helvar | Data is subject to change without notice. More information at: www.helvar.com
EL-ngn5
Electronic ballasts for compact fluorescent lamps
14-80 W 220-240 V, 50-60 Hz
A2 BAT
Lamp
type
TC-L
Wattage
No. of
lamps
24
24
24
24
36
36
55
55
80
80
1
2
3
4
1
2
1
2
1
2
Ballast
EL1x24ngn5
EL2x24ngn5
EL3/4x24ngn5
EL3/4x24ngn5
EL1x39/36ngn5
EL2x39/36ngn5
EL1x55ngn5 1)
EL2x55ngn5
EL1x80ngn5
EL2x80ngn5
EEI
Dimensions
Connection
Weight
Circuit
power
Mains
current
Lamp
power
A2
A2 BAT
A2 BAT
A2 BAT
A2
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
1
2
2
2
1
2
2
3
2
3
(p.62)
1
9
7
8
1
9
1
9
1
14
(g)
130
193
208
208
130
195
195
240
192
300
(W)
25
49
73
97
35
69
60
118
86
170
(A)
0.12-0.11
0.24-0.21
0.34-0.30
0.44-0.40
0.16-0.15
0.32-0.29
0.28-0.24
0.54-0.49
0.42-0.36
0.80-0.73
(W)
22.5
22.5
22.5
22.5
32
32
55
55
80
80
Home
Prev
Next
Note: See pages 62-64 for connection diagrams and additional characteristics.
1) Also ENEC approved for 55 W T5-C lamps
Dimensions
Lenght 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
190
30
21
180
2
280
30
21
270
360
30
21
350
d
c
a
b
d
Delivery information
Ballast
EL1 x ngn5
EL2 x ngn5 & EL3/4 x ngn5
EL2x55ngn5 & EL2x80ngn5
Transportation package
Unit package
Pallet
Minimum Plastic One-way pallet Pallet
1200 x 820
weight
height
delivery binding
strip
amount
(pcs.)
(kg)
(cm)
10
2000
260-300
48
2000
400-450
56
10
1500
400-420
56
10
Helvar | Data is subject to change without notice. More information at: www.helvar.com
55
EL-TCs
Electronic ballasts for compact fluorescent lamps
10-40 W 220-240 V, 50-60 Hz
A2
Lamp
type
TC-L
TC-F
Wattage
No. of
lamps
18
18
18
24
24
24
36
36
36
36
40
40
18
18
18
24
24
24
36
36
36
1
1
2
1
1
2
1
1
1
2
1
1
1
1
2
1
1
2
1
1
2
Ballast
EL1/2x18-42TCs
EL1x18-42TCs
EL1/2x18-42TCs
EL1/2x18-42TCs
EL1x18-42TCs
EL1/2x18-42TCs
EL1/2x36/38TCs
EL1x18-42TCs 1)2)
EL1/2x18-42TCs 1)2)
EL1/2x36/38TCs
EL1/2x18-42TCs 1)
EL1x18-42TCs
EL1/2x18-42TCs
EL1x18-42TCs
EL1/2x18-42TCs
EL1/2x18-42TCs
EL1x18-42TCs
EL1/2x18-42TCs
EL1/2x36/38TCs
EL1/2x18-42TCs 1)2)
EL1/2x36/38TCs
EEI
Connection
Weight
Circuit
power
Mains
current
Power
factor
Lamp
power
A2
A2
A2
A2
A2
A2
A2 BAT
A2
A2
A2 BAT
A2
A2
A2
A2
A2
A2
A2
A2
A2 BAT
A2
A2 BAT
(p.62)
11
13
12
11
13
12
11
13
12
12
11
13
11
13
12
11
13
12
11
12
12
(g)
132
125
132
132
125
132
132
125
132
132
132
125
132
125
132
132
125
132
132
132
132
(W)
17
17
32
26
26
48
37
31
31
72
42
42
17
17
32
26
26
48
37
31
72
(A)
0.08
0.08
0.14
0.12
0.12
0.21
0.17
0.14
0.14
0.32
0.19
0.19
0.08
0.08
0.14
0.12
0.12
0.21
0.17
0.14
0.32
0.94c
0.94c
0.97
0.95
0.95
0.98
0.96
0.96
0.96
0.97
0.98
0.98
0.94c
0.94c
0.97
0.95
0.95
0.98
0.96
0.96
0.97
(W)
14.8
14.8
14.8
23
23
22.3
34
28
28
33
39
39
14.8
14.8
14.8
23
23
22.3
34
28
33
Note: See pages 62-63 for connection diagrams and additional characteristics.
1) Tested and recommended by Helvar, not ENEC approved
2) Light output 93 %
Dimensions
Length 'a' (mm) 103.5
Width 'b' (mm) 67
Height 'c' (mm) 28
'd' (mm) 83.5
e (mm) 57.5
f (mm) 93.5
g (mm) 25.5
Delivery information
Ballast
Unit package
Transportation package
Pallet
Pallet Pallet
Minimum Carton
Box
820x1280 weight height
delivery
amount
(pcs.)
(kg)
(cm)
EL-TCs
60
1800
260
105
56
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
EL-TCs
Electronic ballasts for compact fluorescent lamps
10-40 W 220-240 V, 50-60 Hz
A2
Lamp
type
TC-DD
T5c
T5
T8
TC-SE
Wattage
No. of
lamps
10
16
21
28
38
38
22
22
40
40
14
21
28
30
9
9
9
11
11
11
1
1
1
1
1
2
1
1
1
1
1
1
1
2
1
1
2
1
1
2
Ballast
EL1/2x9-13TCs
EL1/2x9-13TCs
EL1/2x18-42TCs 1)
EL1/2x18-42TCs
EL1/2x36/38TCs
EL1/2x36/38TCs
EL1/2x18-42TCs
EL1x18-42TCs
EL1/2x18-42TCs
EL1x18-42TCs
EL1/2x9-13TCs 1)
EL1/2x9-13TCs 1)
EL1/2x9-13TCs 1)
EL2x32/42TCs 1)
EL1/2x9-13TCs
EL1x9-13TCs
EL1/2x9-13TCs
EL1/2x9-13TCs
EL1x9-13TCs
EL1/2x9-13TCs
EEI
Connection
Weight
Circuit
power
Mains
current
Power
factor
Lamp
power
A2
A2
A2
A2
A2 BAT
A2 BAT
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
(p.62)
11
11
11
11
11
12
11
13
11
11
11
11
11
11
11
13
12
11
13
12
(g)
118
118
132
132
132
132
132
125
132
125
118
118
118
132
118
110
118
118
110
118
(W)
12
17
25
29
38
74
25
25
41
41
16
22.5
31
57.5
10
10
18
14
14
27
(A)
0.05
0.08
0.11
0.13
0.17
0.32
0.12
0.12
0.19
0.19
0.07
0.10
0.14
0.25
0.05
0.05
0.08
0.07
0.07
0.12
0.91c
0.95
0.97
0.97
0.96
0.97
0.95
0.95
0.98
0.98
0.95
0.97
0.97
0.97
0.9c
0.9c
0.96
0.93c
0.93c
0.98
(W)
10.0
15
22.3
27.0
34.8
34
22.6
22.6
38.6
38.6
14.7
21
28.2
26.6
8.5
8.5
8.5
12.8
12.8
12.9
Home
Prev
Next
Note: See pages 62-63 for connection diagrams and additional characteristics.
1) Tested and recommended by Helvar, not ENEC approved
Dimensions
Length 'a' (mm) 103.5
Width 'b' (mm) 67
Height 'c' (mm) 28
'd' (mm) 83.5
e (mm) 57.5
f (mm) 93.5
g (mm) 25.5
Delivery information
Ballast
Unit package
Transportation package
Pallet
Pallet Pallet
Minimum Carton
Box
820x1280 weight height
delivery
amount
(pcs.)
(kg)
(cm)
EL-TCs
60
1800
260
105
Helvar | Data is subject to change without notice. More information at: www.helvar.com
57
EL-TCs
Electronic ballasts for compact fluorescent lamps
9-26 W 220-240 V, 50-60 Hz
A2
Lamp
type
TC-DE
PL-R
Wattage
No. of
lamps
10
10
10
13
13
13
18
18
18
26
26
26
26
14
14
14
17
17
17
1
1
2
1
1
2
1
1
2
1
1
2
2
1
1
2
1
1
2
Ballast
EL1/2x9-13TCs
EL1x9-13TCs
EL1/2x9-13TCs
EL1/2x9-13TCs
EL1x9-13TCs
EL1/2x9-13TCs
EL1/2x18TCs
EL1x18TCs
EL1/2x18TCs
EL1/2x18-42TCs
EL1x18-42TCs
EL1/2x18-42TCs
EL2x32/42TCs
EL1/2x14/17TCs 1)
EL1x14/17TCs 1)
EL1/2x14/17TCs 1)
EL1/2x14/17TCs 1)
EL1x14/17TCs 1)
EL1/2x14/17TCs
EEI
Connection
Weight
Circuit
power
Mains
current
Power
factor
Lamp
power
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
A2 BAT
(p.62)
11
13
12
11
13
12
11
13
12
11
13
12
12
11
13
12
11
13
12
(g)
118
110
118
118
110
118
120
113
120
132
125
132
132
131
126
131
131
126
131
(W)
10
10
20
15
15
28
19
19
36
27
27
51
53
18
18
34
21.5
21.5
41
(A)
0.05
0.05
0.09
0.07
0.07
0.13
0.09
0.09
0.16
0.13
0.13
0.23
0.24
0.08
0.08
0.15
0.1
0.1
0.18
0.9c
0.9c
0.97
0.94c
0.94c
0.98
0.96
0.96
0.98
0.96
0.96
0.98
0.97
0.92c
0.92c
0.96
0.93c
0.93c
0.96
(W)
8.9
8.9
8.9
13.8
13.8
13.5
16.9
16.9
16.9
24.7
24.7
23.8
24
15.8
15.8
15.5
19.3
19.3
18.6
Dimensions
Length 'a' (mm) 103.5
Width 'b' (mm) 67
Height 'c' (mm) 28
'd' (mm) 83.5
e (mm) 57.5
f (mm) 93.5
g (mm) 25.5
Delivery information
Ballast
Unit package
Transportation package
Pallet
Pallet Pallet
Minimum Carton
Box
820x1280 weight height
delivery
amount
(pcs.)
(kg)
(cm)
EL-TCs
60
1800
260
105
58
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
EL-TCs
Electronic ballasts for compact fluorescent lamps
13-57 W 220-240 V, 50-60 Hz
A2
Lamp
type
TC-TE
Wattage
No. of
lamps
13
13
13
18
18
18
26
26
26
26
32
32
32
42
42
42
57
57
1
1
2
1
1
2
1
1
2
2
1
1
2
1
1
2
1
1
Ballast
EEI
Connection
Weight
Circuit
power
Mains
current
Power
factor
Lamp
power
EL1/2x9-13TCs
EL1x9-13TCs
EL1/2x9-13TCs
EL1/2x18TCs
EL1x18TCs
EL1/2x18TCs
EL1/2x18-42TCs
EL1x18-42TCs
EL1/2x18-42TCs
EL2x32/42TCs
EL1/2x18-42TCs
EL1x18-42TCs
EL2x32/42TCs
EL1/2x18-42TCs
EL1x18-42TCs
EL2x32/42TCs
EL1/2x18-42TCs
EL1x18-42TCs
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
(p.62)
11
13
12
11
13
12
11
13
12
12
11
13
12
11
13
12
11
13
(g)
118
110
118
120
113
120
131
125
131
131
131
125
131
131
125
131
131
125
(W)
15
15
28
19
19
36
27
27
51
53
32
32
64
44
44
85
58.5
58.5
(A)
0.07
0.07
0.13
0.09
0.09
0.16
0.13
0.13
0.23
0.24
0.15
0.15
0.29
0.2
0.2
0.38
0.26
0.26
0.94c
0.94c
0.98
0.96
0.96
0.98
0.96
0.96
0.98
0.97
0.97
0.97
0.98
0.98
0.98
0.98
0.99
0.99
(W)
13.8
13.8
13.5
16.9
16.9
16.9
24.7
24.7
23.8
24
29.4
29.4
28.5
42.2
42.2
40.5
54
54
Home
Prev
Next
Note: See pages 62-63 for connection diagrams and additional characteristics.
Dimensions
Length 'a' (mm) 103.5
Width 'b' (mm) 67
Height 'c' (mm) 28
'd' (mm) 83.5
e (mm) 57.5
f (mm) 93.5
g (mm) 25.5
Delivery information
Ballast
Unit package
Transportation package
Pallet
Pallet Pallet
Minimum Carton
Box
820x1280 weight height
delivery
amount
(pcs.)
(kg)
(cm)
EL-TCs
60
1800
260
105
Helvar | Data is subject to change without notice. More information at: www.helvar.com
59
EL-s, EL-su
Electronic ballasts for compact fluorescent lamps
18-80 W 220-240 V, 50-60 Hz
Only 21 mm high
Optimal lamp operation
Wide operational ambient temperature range
Standard & sidemount possibilities
Low power losses
Silent operation
Stabilized flickerfree light
High power factor
A2
Lamp
type
TC-L
Wattage
No. of
lamps
18
18
24
24
24
24
26
26
26
26
28
28
28
28
36
36
40
40
40
55
55
80
80
1
1
1
2
3
4
1
1
2
2
1
1
2
2
1
2
1
1
2
1
2
1
2
Ballast
EEI
EL1x36/40/18s
EL1x36/40s-u 1) 2)
EL1x24s
EL2x24s
EL3/4x24s-u 1)
EL3/4x24s-u 1)
EL1x14-35s 2)3)
EL1x14-35s-u 2)3)
EL2x14-35s 2)3)
EL2x14-35s-u 2)3)
EL1x14-35s 2)3)
EL1x14-35s-u 2)3)
EL2x14-35s 2)3)
EL2x14-35s-u 2)3)
EL1x39/36s
EL2x39/36s
EL1x36/40/18s
EL1x36/40s-u 1)
EL2x36/40s
EL1x55s
EL2x55s
EL1x80s
EL2x80s-u 1)
Dimensions Connection
A2
A2
A2
A2
A2 BAT
A2 BAT
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2
A2 BAT
1
3
1
2
3
3
1
1
2
2
1
1
2
2
1
2
1
3
2
1
2
1
4
(p.62)
1
1
1
2
7
8
1
1
3
4
1
1
3
4
1
2
1
1
2
1
2
1
4
Weight
Circuit
power
Mains
current
Lamp
power
(g)
190
190
190
230
215
215
175
175
250
250
175
175
250
250
190
245
190
190
245
200
260
200
305
(W)
18
18
25
49
73
97
27
27
55
55
27
27
55
55
35
69
45
45
87
59.5
117
85
170
(A)
0.08
0.08
0.12-0.11
0.24-0.21
0.34-0.30
0.44-0.40
0.12
0.12
0.24
0.24
0.12
0.12
0.24
0.24
0.16-0.15
0.32-0.29
0.20-0.18
0.20-0.18
0.40-0.36
0.28-0.25
0.55-0.50
0.40-0.36
0.80-0.73
(W)
16
16
22.5
22.5
22.5
22.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
24.5
32
32
40
40
40
55
55
80
80
Home
Prev
Next
Note: See pages 62-63 for connection diagrams and additional characteristics.
1) With terminals for both manual and automatic wiring(IDC & push-in)
2) Tested and recommended by Helvar, not ENEC approved
3) Cap 2GX11
Dimensions
drawing
Length 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
a
280
30
21
270
2
a
360
30
21
350
3
b
280
30
21
270
4
b
360
30
21
350
Delivery information
Ballast
Unit package
Transportation package
Pallet
Minimum Plastic One-way pallet Pallet
1200 x 820
weight
height
delivery binding
strip
amount
(pcs.)
(kg)
(cm)
EL1 x s
10
2000
350 - 420
57
1500
395
57
EL2 x s
10
1500
390
57
EL3/4 x s
10
60
Helvar | Data is subject to change without notice. More information at: www.helvar.com
d
c
a
b
d
d
c
a
b
d
EL-s
Electronic ballasts for compact fluorescent lamps
18-80 W 220-240 V, 50-60 Hz
Only 21 mm high
Optimal lamp operation
Wide operational ambient temperature range
Standard & sidemount possibilities
Low power losses
Silent operation
Stabilized flickerfree light
High power factor
A2
Lamp
type
TC-F
Wattage
No. of
lamps
18
18
24
24
24
24
36
36
1
1
1
2
3
4
1
2
Ballast
EEI
EL1x36/40/18s
EL1x36/40s-u 1) 2)
EL1x24s
EL2x24s
EL3/4x24s-u 1) 2) 3)
EL3/4x24s-u 1) 2) 3)
EL1x39/36s
EL2x39/36s
Dimensions Connection
A2
A2
A2
A2
A2 BAT
A2 BAT
A2
A2
1
3
1
2
1
2
1
2
(p.62)
1
1
1
2
1
2
1
2
Weight
Circuit
power
Mains
current
Lamp
power
(g)
190
190
190
230
215
215
190
245
(W)
18
18
25
49
73
97
35
69
(A)
0.08
0.08
0.12-0.11
0.24-0.21
0.34-0.30
0.44-0.40
0.16-0.15
0.32-0.29
(W)
16
16
22.5
22.5
22.5
22.5
32
32
Home
Prev
Next
Note: See pages 62-63 for connection diagrams and additional characteristics.
1) With terminals for both manual and automatic wiring(IDC & push-in)
2) Tested and recommended by Helvar, not ENEC approved
3) For 3/4x24W TC-F lamps, Ta= >18C
Dimensions
drawing
Length 'a' (mm)
Width 'b' (mm)
Height 'c' (mm)
'd' (mm)
1
a
280
30
21
270
2
a
360
30
21
350
3
b
280
30
21
270
4
b
360
30
21
350
Delivery information
Ballast
Unit package
Transportation package
Pallet
Minimum Plastic One-way pallet Pallet
1200 x 820
weight
height
delivery binding
strip
amount
(pcs.)
(kg)
(cm)
EL1 x s
10
2000
350 - 420
57
1500
395
57
EL2 x s
10
1500
390
57
EL3/4 x s
10
Helvar | Data is subject to change without notice. More information at: www.helvar.com
d
c
a
b
d
d
c
a
b
d
61
Connection diagrams
EL-ngn5, EL-s, EL-su, EL-ngn, EL-es, EL-TCs
NOTE: All wiring to the connectors marked with a red dot (hot wires) should be as short as possible.
Home
1
2
3
4
5
6
Prev
Next
10
11
12
5
6
7
1
2
3
4
8
9
10
13
14
62
EL2x14-35s, EL2x49s
EL3/4x14s-u, EL3/4x18s-u, EL3/4x24s-u, EL3/4x18ngn (four lamp connection), EL3/4x14ngn5, EL3/4x24ngn5, EL4x14ngn5
10
EL4x18ngn, EL4x18es
11
12
13
14
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Characteristics
EL-s / EL-su
EL-ngn
EL-ngn5
EL-es
EL-TCs
Max.temperature at tc point
75 C 3) 4)
75 C
75 C 9)
75 C
75 C
-20+50 C 7)
-20...+50 C
-20...+50 C
-15...+50 C
-20+50 C
-40+80 C
-40...+80 C
-40...+80 C
-40...+80 C
-40+80 C
no condensation
> 50 000
AC Range
DC range (starting voltage >190VDC)
> 60 000
198-264 VAC
> 50 000
198-264 VAC
> 20 000
198-264 VAC
> 50 000
198-264 VAC
176-280 VDC
176-280 VDC
176-280 VDC 1)
320 VAC, 1 h
320 VAC, 1 h
320 VAC, 1 h
320 VAC, 1 h
320 V / 1 h
0.98
0.98
0.98
0.98
> 0.95
< 0.4 mA
< 0.4 mA
< 0.4 mA
< 0.4 mA
< 0.4 mA
400 V
350 V 8)
400 V 8)
350 V 8)
250 V 2)
50 000 h, at tc
60 000 h, at tc
60 000 h,10) at tc
50 000 h, at tc
50 000 h, at tc
2m
1.5 m
2m
1.5 m
1 m / 2 m (hot / cold)
~1.0 s
<1s
~1 s
<2s
~1 s
Home
Prev
Next
Standards
EL-s / EL-su
EL-ngn
EL-ngn5
EL-es
Preheat starting
EL-TCs
>0,3
~1
* EN 60081 for T5 & T8 fluorescent lamps, EN 60901 for compact fluorescent lamps
Helvar | Data is subject to change without notice. More information at: www.helvar.com
63
64
Ta = 50
Ta = 60
Tc (C)
Lifetime (h)
Tc (C)
Lifetime (h)
Tc (C)
Lifetime (h)
EL1x14-35ngn5
1 x 14
43
>100 000
54
>100 000
64
100 000
EL1x14-35ngn5
1 x 21
44
>100 000
55
>100 000
65
100 000
EL1x14-35ngn5
1 x 28
47
>100 000
58
>100 000
68
100 000
EL1x14-35ngn5
1 x 35
49
>100 000
59
>100 000
69
80 000
EL1x24ngn5
1 x 24
51
>100 000
61
>100 000
71
80 000
EL1x39/36ngn5
1 x 36
55
>100 000
65
>100 000
75
70 000
EL1x39/36ngn5
1 x 39
55
>100 000
65
>100 000
75
70 000
EL1x49ngn5
1 x 49
52
>100 000
62
>100 000
72
70 000
EL1x54ngn5
1 x 54
53
>100 000
63
>100 000
73
65 000
EL1x55ngn5
1 x 55
55
>100 000
65
>100 000
75
70 000
EL1x80ngn5
1 x 80
55
>100 000
65
>100 000
75
60 000
EL2x14-35ngn5
2 x 14
49
>100 000
59
>100 000
69
>100 000
EL2x14-35ngn5
2 x 21
50
>100 000
60
>100 000
70
>100 000
EL2x14-35ngn5
2 x 28
52
>100 000
63
>100 000
73
80 000
EL2x14-35ngn5
2 x 35
55
>100 000
65
>100 000
75
60 000
EL2x24ngn5
2 x 24
50
>100 000
60
>100 000
70
70 000
EL2x39/36ngn5
2 x 39
55
>100 000
65
>100 000
75
60 000
EL2x39/36ngn5
2 x 36
55
>100 000
65
>100 000
75
60 000
EL2x49ngn5
2 x 49
55
>100 000
65
>100 000
75
60 000
EL2x54ngn5
2 x 54
65
>100 000
75
60 000
EL2x55ngn5
2 x 55
60
>100 000
70
60 000
EL2x80ngn5
2 x 80
65
>100 000
75
60 000
EL3/4x14ngn5
3 x 14
52
>100 000
62
>100 000
72
80 000
EL3/4x14ngn5
4 x 14
55
>100 000
65
>100 000
75
60 000
EL4x14ngn5
4 x 14
55
>100 000
65
>100 000
75
60 000
EL3/4x24ngn5
3 x 24
50
>100 000
60
>100 000
70
90 000
EL3/4x24ngn5
4 x 24
55
>100 000
65
>100 000
75
65 000
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
Home
Prev
Next
Helvar | Data is subject to change without notice. More information at: www.helvar.com
65
freedom in lighting
Home
Prev
66
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Next
EP-h
Electronic Ballasts for High Intensity Discharge Lamps
20 -70 W 220-240 V, 50-60 Hz
HI
Wattage
Ballast
20
35
50
70
EP1x20h
EP1x35h
EP1x50h
EP1x70h
BEC *
A2
A2
A2
A2
Power
losses
Dimensions
(W)
3.5
4.5
5.3
6.8
(no.)
1
1
2
2
A2*
Circuit
power
Mains
current
Power
factor
(W)
23.5
43.5
55.3
79.8
(A)
0.11-0.10
0.20-0.18
0.25-0.23
0.36-0.33
> 0.95
> 0.98
> 0.98
> 0.99
Weight
(g)
135
135
155
195
Lamp
power
Ignition
voltage
(W)
20
39
50
73
(kV pk)
<5
<5
<5
<5
Home
Prev
Next
Dimensions
LENGTH 'a' (mm)
WIDTH 'b' (mm)
HEIGHT 'c' (mm)
'd' (mm)
'e' (mm)
'f' (mm)
'g' (mm)
1
95
60
30
51
82
141
31.5
2
105
65
30
56
92
151
31.5
d b
Delivery information
Unit package
Ballast
Transportation package
Minimum Carton One-way pallet
Pallet
Pallet
delivery
box
1200 x 820
weight
height
amount
(pcs.)
(kg)
(cm)
EP1x20h
10
1680
260
68
1680
260
68
EP1x35h
10
1680
290
72
EP1x50h
10
1680
360
72
EP1x70h
10
EP-sr
60
Helvar | Data is subject to change without notice. More information at: www.helvar.com
67
EP-h
Connection details
Ballast lamp distance:
Terminal type:
Terminals suitable for:
Wire strip length:
L
N
Lo
150 pF / 1.5 m
Push in
solid and stranded wire 0.5 - 2.5 mm2
10 - 11 mm
<5kV
Hi
Characteristics
Max.temperature at tc point
Ambient temperature range
Storage temperature range
Maximum relative humidity
Type of protection
AC range
Earth leakage current
Maximum working voltage (Uout)
Lifetime (90 % survival)
EP1x...h
Home
75 C
-20+50 C *
-40+80 C
no condensation
IP20
198-264 VAC
< 0,4 mA
350 V
50 000 h, at Tc
Prev
Next
Standards
General, safety and particular
requirements according to
EMC immunity according to
EP1x...h
IEC/EN 60347-1,
IEC/EN 61347-2-12
IEC/EN 61547
IEC/EN 61000-3-2
IEC/EN 61000-4-5
IEC/EN 55015
30 < P 75
85
75 < P 105
87
90
P > 405
92
68
Helvar | Data is subject to change without notice. More information at: www.helvar.com
EP-h
Lamp compatibility for EP1x...
20 W
EP1x20h
35 W
EP1x35h
50 W
EP1x50h
Manufacturer
TYPE
(cap)
TYPE
(cap)
OSRAM
HCI-TF
HCI-TC
HCI-R111 HCIPAR
(GU6.5)
(G8.5)
(GX8.5)
(E27)
HCI-T
HCI-TF
HCI-TC
HCI-TX/P
HCI-R111
HCI-PAR
HCI-E/P
(G12)
(GU6.5)
(G8.5)
(GU8.5)
(GX8.5)
(E27)
(E27)
PHILIPS
CDM-T
CDM-T Evolution
CDM-TC
CDM-TC Evolution
CDM-Tm
CDM-Rm
CDM-R111
(G12)
(G12)
(G8.5)
(G8.5)
(GU6.5)
(GX10)
(GX8.5)
CDM-T
CDM-T Elite
CDM-T Evolution
CDM-TC
CDM-TC Elite
CDM-TC Evolution
CDM-Tm Elite
CDM-Rm Elite
CDM-R
CDM-R Eite
CDM-R111
(G12)
(G12)
(G12)
(G8.5)
(G8.5)
(G8.5)
(GU6.5)
(GX10)
(E27)
(E27)
(GX8.5)
CMH 20/T
CMH 20/T
CMH 20/T
CMH 20/PAR
(G12)
(G8.5)
(GU6.5)
(E27)
CMH 35/T
CMH 35/T
CMH 35/T
CMH 35/TC
CMH 35/MR16
CMH 35/PAR
CMH 35/TD
(G12)
(G8.5)
(GU6.5)
(G8.5)
(GX10)
(E27)
(RX7s)
GE
TYPE
CDM-T Elite
CDM-T Fresh
CDM-TC Elite
CDM-TC Fresh
CDM-Tm Elite
CDM-Rm Elite
CDM-R Elite
70 W
EP1x70h
(cap)
TYPE
(cap)
(G12)
(G12)
(G8.5)
(G8.5)
(Gu6.5)
(GX10)
(E27)
HCI-T
HCI-TC
HCI-TS
HCI-T/P
HCI-E/P
HCI-R111
HCI-PAR
HCI-TX/P
HQI-T
HQI-TS
HQI-E
CDM-T
CDM-T Elite
CDM-T Fresh
CDM-TC
CDM-TC Elite
CDM-TC Fresh
CDM-R
CDM-R Elite
CDM-TD
CDM-TD Essential
CDM-TP
CDM-R111
CMH 70/T
CMH 70/T
CMH 70/TC
CMH 70/TD
CMH 70/PAR
CMH 70/E
(G12)
(G8,5)
(RX7s)
(E27)
(E27)
(GX8.5)
(E27)
(GU8.5)
(G12)
(RX7s)
(E27)
(G12)
(G12)
(G12)
(G8.5)
(G8.5)
(G8.5)
(E27)
(E27)
(RX7s)
(RX7s)
(PG12-2)
(GX8.5)
(G12)
(G8.5)
(G8.5)
(RX7s)
(E27)
(E27)
Home
Prev
Next
1x20 HI
1x35 HI
1x50 HI
1x70 HI
EP-h
EP1x20h
EP1x35h
EP1x50h
EP1x70h
Helvar | Data is subject to change without notice. More information at: www.helvar.com
1/2
time
t (s)
135.0
137.0
222.0
188.0
value Calculated
energy
Ipeak2t (A2s)
0.05
0.10
0.13
0.22
69
freedom in lighting
70
Home
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Prev
Next
Offering
HELVAR's fluorescent ballast range offers products to all
relevant energy efficiency classes. This gives flexibility
to luminaire designers and end users to make the right
choices for each application and market sector. The
flexibility in HELVARs production philosophy and product
design, as well as the know-how to benefit from different
materials, gives the right means to react to the latest
demands in energy efficiency classification.
Home
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Prev
Next
71
Lamp
type
T8
tw 130
Lamp
Lamp No. of Lamp Ballast type
wattage lamps current
(W)
15
15
15
15
15
15
16
16
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
18
25
25
25
30
30
30
36
36
36
36
36
36
36
36
1
1
1
2
2
2
1
1
1
1
1
1
1
1
2
2
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
(A)
0.31
0.31
0.31
0.31
0.31
0.31
0.20
0.20
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0,37
0.37
0.29
0.29
0.29
0.365
0.365
0.365
0.43
0.43
0.43
0.43
0.43
0.43
0.37
0.43
L 15 TL3
L 15 A-P
L 15 A
L 30 TL2
L 30 A
L 30 A-P
L 16 DL
L 16 D
L 18 TL2
L 18 TL3
L 18 TL4
L 18 A-T
L 18 A-K
L 18 A-L 1)
L 36 TL2
L 36 TL3
L 36 TL4
L 36 A-K
L 36 A-TK
L 36 A-T
L 40 A-C 1)
L 2x18 A-L
L 2x18 A-N
L 40 A-L 1)
L 15 TL3
L 15 A
L 15 A-P
L 30 TL2
L 30 A
L 30 A-P
L 36 TL2
L 36 TL3
L 36 TL4
L 36 A-K
L 36 A-TK
L 36 A-T
L 40 A-C 1)
L 40 A-L 1)
Ballast
EEI Dimen- Connec- Net Inductive
sions
tion weight
B1
B2
B2
B1
B2
B2
B1
B2
B1
B1
B2
B2
B2
C
B1
B1
B2
B2
B2
B2
C
B2
B2
D
B1
B2
B2
B1
B2
B2
B1
B1
B2
B2
B2
B2
C
D
(p.76)
3
1
1
3
1
1
6
6
3
3
3
1
1
1
3
3
3
1
1
1
1
1
1
1
3
1
1
3
1
1
3
3
3
1
1
1
1
1
(p.76)
1,2
1,2
1,2
4
4
4
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
4
4
4
4
4
4
4
4
4
4
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
(kg)
0.76
0.55
0.60
0.82
0.61
0.56
0.32
0.32
0.83
0.76
0.65
0.57
0.61
0.51
0.83
0.78
0.65
0.61
0.57
0.57
0.53
0.51
0,47
0.51
0.76
0.60
0.55
0.82
0.61
0.56
0.83
0.78
0.65
0.61
0.57
0.57
0.53
0.51
0.31
0.31
0.35
0.45
0.50
0.50
0.43
0.46
0.30
0.30
0.30
0.32
0.32
0.35
0.45
0.45
0.45
0.50
0.50
0.50
0.53
0.55
0,55
0.55
0.46
0.50
0.46
0.45
0.45
0.45
0.43
0.43
0.43
0.45
0.45
0.45
0.50
0.50
Temp.
rise
t (C)
40/70
50/95
55/80
30/70
55/110
50/125
60/150
65/150
35/60
40/70
45/80
50/95
50/95
65/90
35/90
40/90
45/110
50/145
50/140
50/155
55/160
65 / 65
65/160
35/70
40/80
40/95
30/70
55/110
50/125
35/90
40/90
45/110
50/145
50/140
50/155
55/160
65/160
Compensation
Mains
Parallel Ck
current
230/250V
10 %
(F)
(A)
4.0
0.12
4.0
0.12
4.0
0.12
4.5
0.21
4.5
0.20
4.5
0.21
2.0
0.11
2.0
0.11
4.5
0.14
4.5
0.14
4.5
0.14
4.5
0.14
4.5
0.14
4.5
0.14
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4,5
0,23
4.5
0.23
3.5
0.15
3.5
0.15
3.5
0.15
4.5
0.18
4.5
0.19
4.5
0.18
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
Note: See page 76 for connection diagrams, dimensions and delivery information. See page 126 for ENEC approved combinations.
1) Not available for European Union market
2) Lamps excluded from the CELMA EEI directive do not have an EEI classification
72
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
L-A... / L-T...
Magnetic ballasts for fluorescent T8 lamps
38 - 58 W 230 V, 50 Hz
Lamp
type
T8
tw 130
Lamp
Lamp No. of Lamp Ballast type
wattage lamps current
(W)
38
38
38
38
38
38
38
38
58
58
58
58
58
58
58
58
58
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
(A)
0.43
0.43
0.43
0.43
0.43
0.43
0.37
0.43
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
0.67
L 36 TL2
L 36 TL3
L 36 TL4
L 36 A-TK
L 36 A-K
L 36 A-T
L 40 A-C 1)
L 40 A-L 1)
L 58 TL2
L 58 TL3
L 58 TL4-220mm
L 58 TL4
L 58 A-S
L 58 A-K
L 58 A-TK
L 58 A-T
L 65 A-P 1)
Ballast
EEI Dimen- Connec- Net Inductive
sions
tion weight
B1
B1
B2
B2
B2
B2
C
D
B1
B1
B2
B2
B2
B2
B2
B2
C
(p.76)
3
3
3
1
1
1
1
1
4
4
4
5
2
2
2
2
2
(p.76)
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
1,2
(kg)
0.83
0.78
0.65
0.57
0.61
0.57
0.53
0.51
1.36
1.30
1.09
1.06
1.00
0.92
0.88
0.88
0.87
0.45
0.45
0.45
0.50
0.48
0.45
0.50
0.48
0.45
0.45
0.45
0.45
0.48
0.48
0.48
0.48
0.50
Temp.
rise
t (C)
35/90
40/90
45/110
50/140
50/145
50/155
55/160
65/160
35/95
40/95
40/110
40/110
45/130
45/135
50/140
50/145
55/145
Compensation
Parallel Ck Mains
current
230/250V
10 %
(F)
(A)
4.5
0.24
4.5
0.24
4.5
0.24
4.5
0.24
4.5
0.24
4.5
0.24
4.5
0.24
4.5
0.24
7.0
0.34
7.0
0.34
7.0
0.34
7.0
0.34
7.0
0.34
7.0
0.34
7.0
0.34
7.0
0.34
7.0
0.34
Home
Prev
Next
Note: See page 76 for connection diagrams, dimensions and delivery information. See page 126 for ENEC approved combinations.
1) Not available for European Union market
Helvar | Data is subject to change without notice. More information at: www.helvar.com
73
Lamp
type
T8
tw 130
Lamp
Lamp No. of Lamp Ballast type
wattage lamps current
Ballast
EEI Dimen- Connec- Net Inductive
sions
tion weight
Temp.
rise
(W)
15
15
1
2
(A)
0.31
0.31
L 15 A
L 30 A-P
B2
B2
(p.76)
1
1
(p.76)
1,2
4
(kg)
0.60
0.56
0.35
0.45
t (C)
55/80
55/125
15
0.31
L 30 A
B2
0.61
0.45
55/125
Compensation
Parallel Ck Mains
current
230/250V
10 %
(F)
(A)
4.0
0.11
4.0
0.17
4.0
16
0.2
L 16 D
B2
0.32
0.45
65/160
2.0
0.10
18
0.37
L 18 A-K
B2
1,2
0.61
0.32
55/90
4.0
0.13
18
0.37
L 20 A-P
1,2
0.56
0.35
60/90
4.0
0.13
18
0.37
L 18 A-L 3)
1,2
0.51
0.33
65/100
4.0
0.13
18
0.37
L 36 TL2
B1
0.83
0.44
35/95
4.0
0.22
18
0.37
L 36 A-K
B2
0.61
0.50
55/155
4.0
0.22
3)
18
0.37
L 36 A-T
B2
0.57
0.52
55/155
4.0
0.22
18
0.37
L 2x18 A-L
B2
0.51
0.52
65/ -
4.0
0.22
B2
C
1
1
4
4
0,48
0.56
0,54
0.53
65
70/160
4
4.0
0,22
0.22
B2
1,2
0.60
0.45
55/90
3.0
0.14
18
0,37
L 2x18 A-N
18
25
2
1
0.37
0.29
L 40 A-P 3)
L 15 A
30
0.365
L 30 A
B2
1,2
0.61
0.45
55/125
4.0
0.17
30
0.365
L 30 A-P
B2
1,2
0.56
0.45
55/125
4.0
0.17
36
0.43
L 36 TL2
B1
1,2
0.83
0.42
35/95
4.5
0.22
36
0.43
L 36 A-K
B2
1,2
0.61
0.45
55/155
4.5
0.22
36
0.43
L 36 A-T
36
38
1
1
0.43
0.43
L 40 A-P
L 36 TL2
B2
C
1
1
1,2
1,2
0.57
0.56
0.47
0.50
55/155
70/160
4.5
4.5
0.22
0.22
B1
1,2
0.83
0.44
35/95
4.0
0.22
38
0.43
L 36 A-K
B2
1,2
0.61
0.45
55/155
4.0
0.23
B2
C
1
1
1,2
1,2
0.57
0.56
0.49
0.52
55/155
70/160
4.0
4.0
0.23
0.23
B1
1,2
1.36
0.42
35/95
7.0
0.32
3)
38
0.43
L 36 A-T
38
58
1
1
0.43
0.67
L 40 A-P 3)
L 58 TL2
58
0.67
L 58 A-K
B2
1,2
0.92
0.48
50/145
7.0
0.32
58
0.67
L 58 A-T
58
70
1
1
0.67
0.70
L 65 A-P 3)
L 75 A-S
B2
C
2
2
1,2
1,2
0.88
0.88
0.48
0.50
55/145
60/145
7.0
7.0
0.32
0.32
B2
1,2
1.00
70
100
1
1
0.70
0.96
L 70 TL4
L100 TE61
B2
1,2
1.09
0.51
0.50
60
45
6.0
6.0
0.41
0.40
- 4)
1,2
1.28
0.52
60/145
10.0
0.55
125
0.94
L100 TE61
- 4)
1.32
0.62c2)
60/145
-1)
Note: See page 76 for connection diagrams, dimensions and delivery information.
1) Essential: Series capacitor 7.2 F 4 % 440 V
2) Capacitive
3) Not available for European Union market
4) Lamps excluded from the CELMA EEI directive do not have an EEI classification
74
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
0.17
Prev
Next
L-A... / L-T...
Magnetic ballasts for fluorescent T8 lamps
15 - 58 W 220 V 50 Hz
Lamp
type
tw 130
Lamp
Lamp No. of Lamp Ballast type
wattage lamps current
(W)
T8
Ballast
EEI Dimen- Connec- Net Inductive
sions
tion weight
(A)
Temp.
rise
Compensation
Parallel Ck Mains
current
230/250V
10 %
(F)
(A)
(p.76)
(p.76)
(kg)
t (C)
18
0.37
L 18 A-L 1)
1,2
0.51
0.35
65/90
4.5
0.16
18
0,37
L 2x18 A-L
B2
0,48
0,56
65
4,5
0,24
18
0,37
L 2x18 A-N
B2
0,47
0,55
65
4,5
0,23
18
0.37
L 40 A-L
1)
0.51
0.55
65/160
4.5
0.24
18
0,37
L 36 A-N
1)
0,49
0,54
65
4,5
0,24
30
0.365 L 30 A-P
36
0.43
36
38
58
B2
1,2
0.56
0.50
45/110
4.5
0.21
L 40 A-L
1)
1,2
0.51
0.50
65/160
4.5
0.24
0,43
L 36 A-N
1)
1,2
0,49
0,52
65
4,5
0,24
0.43
L 40 A-L 1)
1,2
0.51
0.49
65/160
4.5
0.24
0.67
L 65 A-P 1)
1,2
0.88
0.50
55/145
7.0
0.35
Home
Prev
Next
Note: See page 76 for connection diagrams, dimensions and delivery information. 1) Not
available for European Union market
Helvar | Data is subject to change without notice. More information at: www.helvar.com
75
Home
Dimensions
No. 1
Drawing A
Length 'a' (mm) 150
Width 'b' (mm) 42
Height 'c' (mm) 28
'd' (mm) 140
Prev
2
3
4
5
6
A
B
B
B
C
190 150 230 190 85
42
42
42
42 41.5
28 28.8 28.8 28.8 28
180 140 220 180 73
Next
Delivery information
76
Unit package
Transportation package
L 15 - 40 A
10
L 58. - 85 A
L...D / DL
10
30
X
X
(pcs.)
1250
2100
750
2000
1000
1200
1800
1120 x 730
X
X
X
1080 x 770
10
10
10
Eur pallet
1200 x 820
Plastic binding
strip
L 18 - 36TL
L...TS / TLD, L 21TL
L 42 - 100 T/TL/TE
Carton box
Minimum delivery
amount
One-way pallet
730 x 650
Delivery information
Ballast
Pallet weight
2000
960
1200
-
720
-
(kg)
720-1190
1010-1159
1080
A/AK 602-1256
AP/AT 545-1135
720-1215
1800
612
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Pallet
height
(cm)
53
63
45
68
68
58
40
L-A... / L-T...
Magnetic ballasts for compact fluorescent lamps
18 - 36 W 230 V, 50 Hz
Lamp
type
TC-L
tw 130
Lamp
Lamp No. of Lamp Ballast type
wattage lamps current
(W)
18
18
18
18
18
18
18
18
18
18
18
18
18
18
24
24
24
24
24
24
24
36
36
36
36
36
36
36
36
1
1
1
1
1
1
2
2
2
2
2
2
2
2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
(A)
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.345
0.345
0.345
0.345
0.345
0.345
0.345
0.43
0.43
0.43
0.43
0.43
0.43
0.37
0.43
L18 TL2
L18 TL3
L18 TL4
L18 A-K
L18 A-T
L18 A-L 1)
L36 TL2
L36 TL3
L36 TL4
L36 A-K
L36 A-TK
L36 A-T
L40 A-C 1)
L40 A-L 1)
L18 TL2
L18 TL3
L18 TL4
L18 A-K
L18 A-T
L26 TS5-100mm
L18 A-L 1)
L36 TL2
L36 TL3
L36 TL4
L36 A-K
L36 A-TK
L36 A-T
L40 A-C 1)
L40 A-L 1)
Ballast
EEI Dimen- Connec- Net Inductive
sions
tion weight
B1
B1
B2
B2
B2
C
B1
B1
B2
B2
B2
B2
C
D
B1
B1
B1
B2
B2
B2
C
B1
B1
B2
B2
B2
B2
C
D
(p.81)
2
2
2
1
1
1
2
2
2
1
1
1
1
1
2
2
2
1
1
3
1
2
2
2
1
1
1
1
1
(p.81)
3
3
3
3
3
3
4
4
4
4
4
4
4
4
3
3
3
3
3
3
3
3
3
3
3
3
3
3
3
(kg)
0.83
0.78
0.65
0.61
0.57
0.51
0.83
0.78
0.65
0.61
0.57
0.57
0.53
0.51
0.83
0.76
0.65
0.61
0.57
0.50
0.51
0.83
0.78
0.65
0.61
0.57
0.57
0.53
0.51
0.30
0.30
0.30
0.32
0.32
0.35
0.45
0.45
0.45
0.50
0.50
0.50
0.53
0.55
0.38
0.38
0.41
0.40
0.38
0.40
0.42
0.43
0.43
0.43
0.45
0.45
0.45
0.50
0.50
Temp.
rise
t (C)
35/60
40/70
45/80
55/95
50/95
65/90
35/90
40/90
45/110
50/145
50/140
50/155
55/160
65/160
35/60
40/70
45/80
55/95
50/95
55/100
65/90
35/90
40/90
45/110
50/145
50/140
50/155
55/160
65/160
Compensation
Parallel Ck Mains
current
230/250V
10 %
(F)
(A)
4.5
0.15
4.5
0.15
4.5
0.15
4.5
0.15
4.5
0.15
4.5
0.15
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.0
0.16
4.0
0.16
4.0
0.16
4.0
0.16
4.0
0.16
4.0
0.16
4.0
0.16
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
4.5
0.23
Home
Prev
Next
Note: See page 76 for connection diagrams, dimensions and delivery information. See page 126 for ENEC approved combinations.
1) Not available for European Union market
Helvar | Data is subject to change without notice. More information at: www.helvar.com
77
Lamp
type
TC-DD2)
T-R 3)
TC-D
tw 130
Lamp
Lamp No. of Lamp Ballast type
wattage lamps current
(W)
16
16
28
28
28
28
28
38
38
38
38
38
38
38
38
22
22
32
10
10
13
13
18
18
18
26
26
26
26
26
26
26
26
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
(A)
0.20
0.20
0.325
0.325
0.325
0.325
0.325
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.43
0.40
0.40
0.45
0.19
0.19
0.175
0.175
0.22
0.22
0.22
0.325
0.325
0.325
0.325
0.325
0.325
0.325
0.325
L16 DL
L16 D
L18 TL2
L18 TL3
L18 TL4
L18 A-T
L18 A-L 1)
L 36 TL2
L 36 TL3
L 36 TL4
L36 A-K
L36 A-TK
L36 A-T
L40 A-C 1)
L40 A-L 1)
L30 TL2
L30 A 1)
L32 TB2
L13 DL
L13 D
L13 DL
L13 D
L18 TLD-100mm
L18 DL
L18 D
L18 TL2
L18 TL3
L18 TL4
L18 A-T
L18 A-K
L26 TS5-100mm
L26 S-100mm
L18 A-L 1)
Ballast
EEI Dimen- Connec- Net Inductive
sions
tion weight
B1
B2
B1
B1
B2
B2
C
B1
B1
B2
B2
B2
B2
C
D
B1
C
B2
B2
B2
B1
B1
B1
B1
B1
B1
B1
B2
B2
B2
B2
B2
C
(p.81)
4
4
2
2
2
1
1
2
2
2
1
1
1
1
1
2
1
2
4
4
4
4
3
4
4
2
2
2
1
1
3
5
1
(p.81)
8
8
8
8
8
8
8
8
8
8
8
8
8
8
8
7
7
7
5
5
5
5
5
5
5
5
5
5
8
5
5
5
5
(kg)
0.32
0.32
0.83
0.78
0.65
0.57
0.51
0.83
0.78
0.65
0.61
0.57
0.57
0.53
0.51
0.82
0.61
0.62
0.32
0.32
0.32
0.32
0.50
0.32
0.32
0.83
0.78
0.65
0.57
0.61
0.50
0.44
0.51
0.43
0.46
0.48
0.48
0.44
0.50
0.50
0.45
0.45
0.45
0.48
0.45
0.45
0.48
0.48
0.30
0.35
0.40
0.35
0.35
0.45
0.45
0.45
0.45
0.50
0.43
0.43
0.45
0.45
0.45
0.45
0.47
0.45
Temp.
rise
t (C)
60/150
65/150
35/60
40/70
45/80
50/95
65/90
35/90
40/90
45/110
50/145
50/140
50/155
55/160
65/160
40/70
60/110
55/120
50/95
65/120
50/95
65/120
30/60
60/150
65/155
35/60
40/70
45/80
50/95
55/95
50/100
60/140
75/90
Compensation
Mains
Parallel Ck
current
230/250V
10 %
(F)
(A)
2.0
0.11
2.0
0.11
3.5
0.20
3.5
0.20
3.5
0.20
3.5
0.20
3.5
0.20
4.5
0.24
4.5
0.24
4.5
0.24
4.5
0.24
4.5
0.24
4.5
0.24
4.5
0.24
4.5
0.24
5.0
0.17
5.0
0.17
5.0
0.21
2.0
0.08
2.0
0.08
2.0
0.08
2.0
0.08
2.0
0.12
2.0
0.12
2.0
0.13
3.5
0.18
3.5
0.18
3.5
0.18
3.5
0.18
3.5
0.18
3.5
0.18
3.5
0.18
3.5
0.18
Note: See page 76 for connection diagrams, dimensions and delivery information. See page 126 for ENEC approved combinations.
1) Not available for European Union market
2) Also GR 10q; external starter required
3) Cap G10q
78
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
L-D
Magnetic ballasts for compact fluorescent lamps
4 - 13 W 230 V, 50 Hz
Lamp
type
T5
TC-S
tw 130
Lamp
Lamp No. of Lamp Ballast type
wattage lamps current
(W)
4
4
6
6
6
8
8
8
8
8
13
13
5
5
5
5
7
7
7
7
9
9
9
9
11
11
1
2
1
2
2
1
1
2
2
2
1
1
1
1
2
2
1
1
2
2
1
1
2
2
1
1
(A)
0.17
0.17
0.16
0.16
0.16
0.145
0.145
0.145
0.145
0.145
0.165
0.165
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.18
0.17
0.17
0.17
0.17
0.155
0.155
L8 D
L8 D
L8 D
L13 DL
L13 D
L8 D
L11 D
L13 DL
L16 DL
L16 D
L13 DL
L13 D
L11 DL
L11 D
L13 DL
L13 D
L11 DL
L11 D
L 13 DL
L 13 D
L11 DL
L11 D
L13 DL
L13 D
L11 DL
L11 D
Ballast
EEI Dimen- Connec- Net Inductive
sions
tion weight
B2
B2
B2
B1
B1
B2
B2
B1
B1
B2
B1
B1
B2
B2
B1
B1
B1
B2
B1
B1
B1
B2
B1
B1
B1
B2
(p.81)
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
(p.81)
1
2
1
2
2
1
1
2
2
2
1
1
5
5
6
6
5
5
6
6
5
5
6
6
5
5
(kg)
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.25
0.35
0.30
0.45
0.45
0.33
0.33
0.50
0.43
0.50
0.45
0.45
0.28
0.25
0.35
0.40
0.30
0.28
0.45
0.45
0.32
0.33
0.55
0.55
0.43
0.43
Temp.
rise
t (C)
65/90
65/90
65/90
50/95
65/120
65/90
60/85
50/95
60/150
65/150
50/95
65/120
60/95
60/85
50/95
65/120
60/95
60/85
50/95
65/120
60/95
60/85
50/95
65/120
60/95
60/85
Compensation
Mains
Parallel Ck
current
230/250V
10 %
(F)
(A)
2.0
0.06
2.0
0.06
2.0
0.06
2.0
0.08
2.0
0.08
2.0
0.06
2.0
0.06
2.0
0.10
2.0
0.11
2.0
0.11
2.0
0.10
2.0
0.10
2.0
0.07
2.0
0.07
2.0
0.08
2.0
0.08
2.0
0.07
2.0
0.07
2.0
0.09
2.0
0.09
2.0
0.07
2.0
0.07
2.0
0.10
2.0
0.10
2.0
0.08
2.0
0.08
Home
Prev
Next
Note: See page 76 for connection diagrams, dimensions and delivery information. See page 126 for ENEC approved combinations.
Helvar | Data is subject to change without notice. More information at: www.helvar.com
79
T5
TC-S
TC-D
TC-L
TC-DD2)
T-R3)
tw 130
Lamp
Lamp No. of Lamp Ballast type
wattage lamps current
(W)
4
4
6
6
8
8
8
13
5
5
7
7
9
9
11
10
13
18
26
26
26
26
18
18
18
18
18
18
18
24
24
36
36
36
36
16
28
22
1
2
1
2
1
1
2
1
1
2
1
2
1
2
1
1
1
1
1
1
1
1
1
1
1
2
2
2
2
1
1
1
1
1
1
1
1
1
(A)
0.17
0.17
0.16
0.16
0.145
0.145
0.145
0.165
0.18
0.18
0.18
0.18
0.17
0.17
0.155
0.19
0.175
0.22
0.325
0.325
0.325
0.325
0.37
0.37
0.37
0.37
0.37
0.37
0.37
0.345
0.345
0.43
0.43
0.43
0.43
0.195
0.32
0.40
L8D
L8D
L8D
L 13 D
L8D
L 11 D
L 16 D
L 13 D
L 11 D
L 13 D
L 11 D
L 13 D
L 11 D
L 13 D
L 11 D
L 13 D
L 13 D
L 18 D
L 18 A-K
L 26 TS5-100
L 26 S-100
L 20 A-P 1)
L 18 TL4
L 18 A-K
L 20 A-P 1)
L 36 TL2
L 36 A-K
L 36 A-T
L 40 A-P 1)
L 26 TS5-100
L 20 A-P 1)
L 36 TL2
L 36 A-K
L 36 A-T
L 40 A-P 1)
L 16 D
L 20 A-P 1)
L 30 A
Ballast
EEI Dimen- Connec- Net Inductive
sions
tion weight
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B2
B1
B2
B2
B2
C
B2
B2
C
B1
B2
B2
C
B2
C
B1
B2
B2
C
B2
C
B2
(p.81)
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
4
1
3
5
1
2
1
1
2
1
1
1
3
1
2
1
1
1
4
1
1
(p.81)
1
2
1
2
1
1
2
1
5
6
5
6
5
6
5
5
5
5
3
5
5
5
3
3
3
4
4
4
4
3
3
3
3
3
3
8
8
7
(kg)
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.32
0.61
0.50
0.44
0.56
0.65
0.61
0.56
0.83
0.61
0.57
0.56
0.50
0.56
0.83
0.61
0.57
0.56
0.32
0.56
0.51
0.25
0.35
0.30
0.45
0.33
0.33
0.45
0.45
0.25
0.40
0.30
0.45
0.33
0.55
0.43
0.35
0.45
0.45
0.43
0.43
0.45
0.45
0.29
0.32
0.35
0.44
0.50
0.52
0.53
0.38
0.42
0.42
0.45
0.47
0.50
0.45
0.50
0.35
Temp.
rise
t (C)
60/90
60/90
60/90
65/110
60/90
65/90
65/90
65/110
65/90
65/110
65/90
65/110
65/90
65/110
65/90
65/110
65/110
65/155
55/90
50/110
60/150
60/90
45/80
55 /90
60/90
35/95
55/155
55/155
70/160
55/110
60/90
35/95
55/155
55/155
70/160
65/160
60/90
60/125
Compensation
Mains
Parallel Ck
current
230/250V
10 %
(F)
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
2.0
3.5
3.5
3.5
3.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
3.5
3.5
4.0
4.0
4.5
4.0
2.0
3.0
4.5
(A)
0.05
0.06
0.05
0.08
0.06
0.06
0.10
0.08
0.06
0.08
0.07
0.09
0.07
0.10
0.08
0.08
0.08
0.12
0.17
0.17
0.17
0.17
0.15
0.15
0.15
0.21
0.21
0.21
0.21
0.15
0.15
0.22
0.22
0.22
0.22
0.11
0.18
0.19
Note: See page 76 for connection diagrams, dimensions and delivery information.
1) Not available for European Union market
2) Cap GR8, also GR 10q; external starter required
3) Cap G10q
80
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
Home
Prev
Dimensions
Next
No. 1
2
3
4
5
Drawing A
B
B
C
D
Length 'a' (mm) 150 150 110 85 110
Width 'b' (mm) 42
42
42 41.5 42
Height 'c' (mm) 28 28.8 28.8 28
26
'd' (mm) 140 140 100 73 100
Delivery information
Unit package
Transportation package
L 15 - 40 A
10
L...D / DL
L 26 S-100mm
30
8
X
X
(pcs.)
1250
2100
2000
1000
1800
2016
1120 x 730
X
X
1080 x 770
10
10
Eur pallet
1200 x 820
Plastic binding
strip
L 18 - 36TL
L...TS / TLD, L 21TL
Carton box
Minimum delivery
amount
One-way pallet
730 x 650
Delivery information
Ballast
960
1800
-
Pallet weight
Pallet
height
(kg)
720-1190
1010-1159
A/AK 602-1256
AP/AT 545-1135
612
925
(cm)
53
63
68
68
40
46
Helvar | Data is subject to change without notice. More information at: www.helvar.com
81
freedom in lighting
82
Home
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Prev
Next
Offering
Ballasts for high pressure mercury
lamps
Helvar offers ballasts for lamps 50 W-400 W. Small wattage
ballasts 50-125 W are equipped with push-in terminal
and higher wattages 250-400 W are equipped with screw
terminal. 250 W is also available with push-in terminal.
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
83
E-LU / E-LUP
Magnetic ballasts for high pressure mercury lamps
80/50 W - 125/80 W 230, 240, 230/240 V, 50 Hz
tw 130
Lamp
type
Lamp
Lamp
wattage
Lamp
current
(W)
(A)
Voltage
Power
losses
Temp.
rise
Compensation
Mains
Parallel Ck
230/250V
current
10 %
(F)
(A)
(p.93)
(p.92)
(kg)
t (C)
230
240
(W) 1)
12.0/10.0
12.5/10.4
1.22
0.50/0.42
70/65
8.0
0.45/0.30
230
14.5/11.5
1.22
0.55/0.50
70/60
10.0
0.70/0.45
230
240
13.4/11.0
14.0/11.6
1.22
0.55/0.50
70/60
10.0
0.70/0.45
230
14.5/12.5
1.22
0.55/0.50
70/60
10.0
0.70/0.45
80/50
HM
Ballast type
Ballast
Dimen- Connec- Net Inductive
sions
tion weight
0.80/0.62 E80/50LU
Note: P in ballast type name means built-in thermal protector (eg. E80/50LUP)
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Prev
Next
1) Winding at 25 C
84
Home
HM
Lamp
Lamp
wattage
Lamp
current
(W)
(A)
125
1.15
E 125 LU
125
1.15
250
Ballast type
Voltage
Power
losses
Ballast
Dimen- Connec- Net Inductive
sions
tion weight
Temp.
rise
Compensation
Parallel Ck Mains
230/250V current
10 %
(F)
(A)
(W) 1)
(p.93)
(p.92)
(kg)
t (C)
220
13.2
1.21
0.55
70
10.0
0.70
E 125 LU
230
13.7
1.22
0.55
70
10.0
0.70
2.13
E 250 SE 3)
230
19.0
1.86
0.55
75
18.0
1.40
250
2.13
E 250 SE
240
20.0
1.86
0.55
75
18.0
1.40
250
2.13
E 250 T,F 2) 4) 5)
230
22.0
2,5
2.10
0.55
65
18.0
1.40
250
2.13
E 250 T 2) 4) 5)
240
23.0
2.10
0.55
70
18.0
1.40
250
2.13
E 250 T 2) 4) 5)
230
240
22.0
23.0
2,5
2.10
0.55
18.0
1.40
400
3.25
E 400 SE 4)
230
28.0
10
3.00
0.57
75
25.0
2.15
400
3.25
E 400 SE 4)
240
29.0
10
3.00
0.56
75
25.0
2.15
400
3.25
E 400 T 2) 4) 5)
230
25.4
3.16
0.60
65
25.0
2.15
400
3.25
E 400 F 2) 4) 5)
240
26.6
3.16
0.60
70
25.0
2.15
3,25
400
E 400 TLC 2) 4) 5)
12
3.6
0.58
55
25
2.15
400
E 400 TLC 2) 4) 5)
3.7
0.56
25
2.15
3,25
400
E 400 TLPC 2) 4) 5)
10
3.7
0.56
25
2.15
400
3.25
E 400 TP,FP 2) 4) 5)
3,6
10
3.16
0.60
25.0
2.15
400
3.25
E 400 TL 2) 4) 5)
3.0
0.59
25
2.15
400
3.25
E 400 TL 2) 4) 5)
11
3.1
0.57
70
25
2.15
400
3.25
E 400 TLP 2) 4) 5)
22.5
23.3
23.3
24.2
23.3
24.2
25.4
26.6
27
29
29
31
29
31
3,25
220
230
230
240
230
240
230
240
220
230
230
240
230
240
12
3.1
0.57
70
25
2.15
3)
65
70
55
60
55
60
65
70
65
70
Home
Prev
Next
1) Winding at 25 C
2) T-type = two and four point fixing
F-type = four point fixing
3) With push-in terminals
4) With screw terminals
5) Product has tw140
Note: P in ballast type name means built-in thermal protector (eg. E400 TP or NK70LUPK)
Helvar | Data is subject to change without notice. More information at: www.helvar.com
85
HS
Lamp
Lamp
wattage
Lamp
current
(W)
(A)
Ballast type
Voltage
Power
losses
Ballast
Dimen- Connec- Net Inductive
sions
tion weight
Temp.
rise
Compensation
Parallel Ck Mains
230/250V
current
10 %
(F)
(A)
(p.93)
(p.92)
(kg)
t (C)
230
240
230
240
230
240
(W) 1)
12.0
12.5
12.0
12.5
14.8
15.0
13
1.22
0.38
70
8.0
0.33
15
1.22
0.38
70
8.0
0.33
13
1.22
0.39
70
12.0
0.43
50
0.75
NK 50 LU
50
0.75
NK 50 LUP
70
1.0
NK 70 LU
70
1.0
NK 70 LU
240
15.0
28
1.22
0.39
70
12.0
0.43
70
1.0
NK 70 LUP
230
240
14.8
15.0
15
1.22
0.39
70
12.0
0.43
70
1.0
NK 70 LUE
220
16.0
28
1.18
0.39
75
12.0
0.43
70
1.0
NK 70 LUPE
230
240
16.0
16.9
15
1.20
0.38
0.36
75
80
12.0
0.43
70
1.0
NK 70 LUPK
240
14.0
29
1.22
0.39
65
12.0
0.43
70
1.0
NK 70 LUPK
230
240
230
240
13.5
14.0
14.5/11.0
15.0/11.5
15
1.22
0.39
65
12.0
0.43
14
1.22
0.39/0.38
75/60
12.0/8.0
0.43/0.33
230
14.5/11.0
15
1.22
0.39/0.38
75/60
12.0/8.0
0.43/0.33
230
240
230
240
15.6
16.6
15.6
16.6
13
1.22
0.44
80
12.0
0.56
13
1.22
0.44
80
12.0
0.56
230
14.5/11.5
13
15
1.27
0.41/0.35
75/65
12.0/12.0
0.56/0.43
220
230
230
240
230
240
230
240
230
240
230
240
230
240
20
21
21
22
21
22
18
1.80
0.41
75
20
0.9
21
1.80
0.40
75
20
0.9
22
1.80
0.40
75
20
0.9
18.0 19.0
15
1.85
0.41
75
20
0.9
18.0 19.0
15
1.85
0.41
75
20
0.9
17.5 18.5
15
2.6
0.40
65
20
0.9
18/11.5
19/12
10
30
2.6
0.38
0.37
60/35
20/12
0.9/0.56
70/50
1.0/0.75 NK 70/50 LU
70/50
100
1.2
NK 100 LU
100
1.2
NK 100 LUP
100/70
1.2/1.0
150
1.8
NK 150 TL 2)
150
1.8
NK 150 TL 2)
150
1.8
NK 150 TLP 2)
150
1.8
NK 150 SE
150
1.8
NK 150 SEP 3)
150
1.8
NK 150 SEPK
150/100
1.8
NK 150/100 SEP
NK 100/70 SEP
1) Winding at 25 C
2) Product has tw140
3) Available also with bottom length 133 mm
Note: P in ballast type name means built-in thermal protector (eg. E400 TP or NK70LUPK)
86
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
HS
Lamp
Lamp
Lamp
wattage current
Ballast type
(W)
(A)
250
3.0
NK 250 SE
250
3.0
250
Voltage
Ballast
Power Dimen- Connec- Net Inductive
losses
sions
tion weight
Compensation
Temp. Parallel Ck Mains
230/250V current
rise
10 %
t (C)
(F)
(A)
(W) 1)
(p.93)
(p.92)
(kg)
230
29
10
23
3.00
0.40
70
32
1.4
NK 250 SE
240
30
10
23
3.00
0.38
80
32
1.4
3.0
NK 250 SEP
230
240
29
30
10
15
3.00
0.38
75
80
32
1.4
250
3.0
NK 250 T
230
28
3,6
16
3.15
0.42
70
32
1.4
250
3.0
NK 250 T,F 2) 3)
18
3.15
0.42
70
75
32
1.4
3.0
NK 250 TLC 2) 3)
18
0.44
65
32
1.4
250
3.0
NK 250 TLPC 2) 3)
21
0.42
65
32
1.4
250
3.0
NK 250 TLPC 2) 3)
22
0.42
65
32
1.4
250
3.0
NK 250 TP,FP 2) 3)
3,6
19
3.15
0.42
70
75
32
1.4
250
3.0
NK 250 TLK 3)
21
2.75
0.43
75
32
1.4
250
3.0
NK 250 TLK 3)
18
2.75
0.43
32
1.4
250
3.0
NK 250 TLPK 3)
28
29
25
26
26
27
26
27
28
29
29
30
30
32
30
32
3,6
250
230
240
220
230
230
240
230
240
230
240
220
230
230
240
230
240
19
2.75
0.43
32
1.4
400
4.4
NK 400 T,F 2) 3)
230
32
4,7
16
4.4
0.40
50
2.2
400
4.4
NK 400 T,F 2) 3)
18
4.4
0.40
50
2.2
4.4
NK 400 TP,FP 2) 3)
4,7
19
4.4
0.40
50
2.2
400
4.4
NK 400 TE, FE 2) 3)
4,7
21
3.6
0.41
75
50
2.2
400
4.4
4,7
22
3.6
0.41
75
50
2.2
600
6.2
NK 600 T/2 2) 3) 4)
32
33
32
33
35
36
35
36
60
62
4,7
400
230
240
230
240
230
240
230
240
230
240
20
6.3
0.44
75
80
65
3.0
600
6.2
NK 600 SE
230
43
14
23
6.9
0.47
75
65
3.0
1000
10.3
NK 1000 F/2 2) 3) 4)
230
240
75
80
20
8.8
0.45
80
100
5.3
5.0
2) 3)
75
80
75
80
70
70
75
70
75
Home
Prev
Next
1) Winding at 25 C
2) T-type = two and four point fixing F-type = four point fixing
3) Product has tw140
4) Supplied as 2 identical ballasts both with the dimensions indicated.
All other technical values are stated for the combined product operating one lamp.
Note: P in ballast type name means built-in thermal protector (eg. NK400 TP or NK600 SEP)
Helvar | Data is subject to change without notice. More information at: www.helvar.com
87
tw 130 &140
(A)
50
0.75 NK50/35LUP
70
Reduced
Lamp current
(W)
Circuit power 3)
Ballast
Compensation
Luminous Circuit Dimen- Connec- Net Inductive Temp. Parallel Mains
flux ()
power
sions
tion weight
rise
Ck
current
reduction reduction
230/250V
10 %
Full
HS
Ballast type
Lamp wattage
Lamp
type
Lamp
(W)
(W)
1)
63
40
~50%
1.0
NK70/50LUP 2)
84
59
100
1.2
NK100/70SEP 2)
115
150
1.8
NK150/50% SEP
250
3.0
400
4.4
(p.93)
(p.92)
(kg)
t (C)
(F)
(A)
37%
24
1.22
0.38
70
8.0
0.33
~50%
29%
24
1.22
0.39
75
12.0
0.43
79
~50%
32%
13
24
1.27
0.41
75
12.0
0.56
166
107
~50%
36%
24
1.85
0.43
75
20
0.90
NK250/50% SEP
274
171
~50%
38%
12
24
3.4
0.41
75
32
1.4
NK400/50% TP 4)
434
288
~50%
34%
24
4.4
0.40
75
50
2.2
1)
Operating instructions
The circuit power can be reduced by using a power reduction ballast with extra tapping for higher impedance, together with a power reduction switch.
Lamps must always be ignited with the higher rated wattage of a ballast and not switched down to reduced wattage before 10 minutes of normal
operation after the ignition of a lamp.
88
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
Lamp
Lamp Lamp
wattage current
(W)
HI
Ballast type
Voltage
(A)
35
0.53
NK 35 LUP
50
0.76
NK 50 LU
50
0.76
NK 50 LUP 6)
6)
70/50
1.0/0.76 NK 70/50 LU 6)
70/50
Ballast
Power Dimen- Connec- Net Inductive
losses
sions
tion weight
Temp.
rise
Compensation
Parallel Ck Mains
230/250V current
10 %
(F)
(A)
(p.93)
(p.92)
(kg)
t (C)
230
240
230
240
230
240
230
240
(W) 1)
9.0
9.4
12
12.5
12
12.5
14.5/11.0
15.0/11.5
15
1.22
0.38
50
6.0
0.23
13
1.22
0.38
70
0.33
15
1.22
0.38
70
0.33
14
1.22
0.39/0.38
75/60
12.0/8.0
0.43/0.33
230
14.5/11.0
15
1.22
0.39/0.38
75/60
12.0/8.0
0.43/0.33
70
1.0
NK 70 LU
240
15.0
28
1.22
0.39
70
12.0
0.43
70
1.0
NK 70 LUP
230
240
14.8
15.0
15
1.22
0.39
70
12.0
0.43
70
1.0
NK 70 LUPK
240
14.0
29
1.22
0.39
65
12.0
0.43
70
1.0
NK 70 LUPK
230
240
13.5
14.0
15
1.22
0.39
65
12.0
0.43
70
1.0
NK 70 LUE
220
16.0
28
1.18
0.39
75
12.0
0.43
70
1.0
NK 70 LUPE
15
1.20
0.38
0.36
75
80
12.0
0.43
1.1
NK 100 LUP
16.0
16.9
15.6
16.6
100
230
240
230
240
13
1.22
0.44
80
12.0
0.56
230
14.5/11.5
13
13
1.27
0.41/0.35
75/65
12.0/12.0
0.56/0.43
220
230
230
240
230
240
230
240
230
240
20
21
21
22
21
22
18.0
19.0
17.5
18.5
18
1.80
0.41
75
20
0.9
21
1.80
0.40
75
20
0.9
22
1.80
0.40
75
20
0.9
15
1.85
0.41
75
20
0.9
15
2.6
0.40
65
20
0.9
100/70
150
1.8
NK 150 TL 2) 3)
150
1.8
NK 150 TL
150
1.8
NK 150 TLP 2) 3)
150
1.8
NK 150 SEP 4) 5)
150
1.8
NK 150 SEPK 4)
2) 3)
Home
Prev
Next
1) Winding at 25 C
2) T-type = two and four point fixing
F-type = four point fixing
3) Product has tw140
4) With push-in terminals
5) Available also with bottom length 133 mm
6) 50 W : Only suitable with CDO lamps
Note: P in ballast type name means built-in thermal protector (eg. NK70LUPK)
Helvar | Data is subject to change without notice. More information at: www.helvar.com
89
HI
Lamp
Lamp Lamp
wattage current
(W)
(A)
250
3.0
Ballast type
NK 250 TLK
5)
Voltage
Ballast
Power Dimen- Connec- Net Inductive
losses
sions
tion weight
Temp.
rise
Compensation
Parallel Ck Mains
230/250V current
10 %
(F)
(A)
220
230
230
240
230
240
(W) 1)
29
30
30
32
30
32
(p.93)
(p.92)
(kg)
t (C)
21
2.75
0.43
75
32
1.4
32
1.4
32
1.4
18
2.75
0.43
19
2.75
0.43
75
80
75
80
29
10
23
3.00
0.40
70
32
1.4
240
30
10
23
3.00
0.38
80
32
1.4
29
30
28
29
10
15
3.00
0.38
80
32
1.4
3,6
19
3.15
0.42
70
75
32
1.4
250
3.0
NK 250 TLK 5)
250
3.0
NK 250 TLPK 5)
250
3.0
NK 250 SE
230
250
3.0
NK 250 SE
250
3.0
NK 250 SEP
250
3.0
NK 250 TP,FP 2) 5)
230
240
230
240
400
3.5
E 400 SE
230
29.0
10
23
3.00
0.51
80
35
2.2
400
3.5
E 400 SE
240
30.0
10
23
3.00
0.49
80
35
2.2
400
4.1
NK 400 TP,FP 2) 4) 5)
19
4.40
0.40
70
75
45
2.2
4.1
NK 400 TE, FE
4,7
21
3.6
0.41
75
45
2.2
400
4.1
4,7
22
3.6
0.41
75
45
2.2
400
3.5
H 400 T
35
2.2
400
3.5
H 400 TP 2) 5)
35
2.2
3.5
400
E 400 TLC
3.5
400
E 400 TLC 2) 5)
3.5
400
E 400 TLPC 2) 5)
32
33
35
36
35
36
24.9
26
24.9
26
22.5
23.3
23.3
24.2
23.3
24.2
4,7
400
230
240
230
240
230
240
230
240
230
240
220
230
230
240
230
240
400
3.5
E 400 T 2) 5)
230
400
3.5
E 400 F 2) 5)
400
3.5
E 400 TL
400
3.5
E 400 TL 5)
400
3.5
E 400 TLP
400
3.5
E 400 TP,FP 2) 5)
1000
9.5
H 1000 F/2
2) 4) 5)
2)4)5)
2) 5)
2) 5)
5)
5)
2) 3) 5)
3,6
18
3.18
0.48
3,6
22
3.18
0.48
70
75
70
75
21
3.6
0.55
65
35
2.15
18
3.7
0.53
65
35
2.15
19
3.7
0.53
65
35
2.15
25
16
3.16
0.49
80
35
2.15
240
26
16
3.16
0.49
80
35
2.15
220
230
230
240
230
240
230
240
230
240
27
29
29
31
29
31
25
26
75
80
18
3.0
0.55
75
35
2.15
21
3.1
0.53
35
2.15
22
3.1
0.53
75
80
75
80
35
2.15
3,6
22
3.16
0.49
80
35
2.15
20
8.8
0.49
85
100
4.6
1) Winding at 25 C
2) T-type = two and four point fixing
F-type = four point fixing
3) Supplied as 2 identical ballasts both with the dimensions indicated
All other technical values are stated for the combined product operating one lamp
4) Check lamp manufacturers data to ensure they specify that the lamp is suitable for HPS ballast
5) Product has tw140
Note: P in ballast type name means built-in thermal protector (eg. E400 TP or NK70LUPK)
90
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
HS / HI
Lamp
Lamp Lamp
Lamp
type wattage current
HS
Voltage
Power
losses
(W) 1)
(p.93)
(p.92)
(kg)
t (C)
ConnecNet Inductive
tion
weight
Temp.
rise
Compensation
Mains
Parallel Ck
230/250V
current
10 %
(F)
(A)
(W)
(A)
150
1.8
NK 150 SE 4)
220
18
11
23
1.8
0.40
75
20
0.9
250
1.8
NK 250 SEL
220
27
10
23
2.6
0.42
80
32
1.4
250
3.0
NK 250 T 2) 7)
220
27
3.6
25
3.1
0.42
70
32
1.4
220(NK)
220 (H) 6)
70
60
20
8.8
0.45
0.49
80
70
100
5.0
1000
HI
Ballast type
Ballast
Dimensions
6)
400
4.4
NK 400 TE 5) 7)
220
32
26
3.6
0.43
75
50
2.2
400
4.4
NK 400 T 2) 5) 7)
220
31
4.7
25
4.4
0.40
70
50
2.2
1000
10.3
NK 1000 F/2 3) 7)
220
72
27
8.8
0.45
80
100
5.3
3,5
400
E 400 TL 2) 7)
220
27.5
17
3.0
0.53
75
35
2.15
Home
Prev
Next
1) Winding at 25 C
2) T-type = two and four point fixing
F-type = four point fixing
3) Supplied as 2 identical ballasts both with the dimensions indicated
All other technical values are stated for the combined product operating one lamp
4) With push-in terminals
5) Can also be used with certain 400 W HI-lamps. Check lamp manufacturers data to ensure they specify that the
lamp is suitable for HPS ballast
6) NK-output for high pressure sodium lamps, H-output for metal halide lamps
7) Product has tw140
Note: P in ballast type name means built-in thermal protector (eg. NK 250 TP or NK 250 FP)
Helvar | Data is subject to change without notice. More information at: www.helvar.com
91
Connection diagrams
HID-ballasts
1
10
11
12
Home
Prev
13
14
15
16
17
18
19
20
21
22
23
24
Next
~50%
92
25
26
29
30
27
Helvar | Data is subject to change without notice. More information at: www.helvar.com
28
Dimensions
NO.
DRAWING
LENGTH 'a' (mm)
WIDTH 'b' (mm)
HEIGHT 'c' (mm)
'd' (mm)
'e' (mm)
'f' (mm)
'g' (mm)
1
a
114
54
45.5
95
2
3
4
5
6
b
b
b
c
c
135 135 165 104 104
70 70 70 70 70
85 85 85 85 85
120 120 150 90 90
35 35 35 90 90
85 108 138 85 108
80 80
7
8
9
c
d
d
135 145 160
70 69 69
85 53 53
100 120 140
100
138
90
10
d
180
69
53
155
11
d
133
69
53
120
12
e
133
104
90.5
120
T-Type
13
f
112
69
53
95
14
e
173
104
90.5
160
F-Type
Home
Prev
Next
da
Delivery information
Ballast
E-LU, E-LUP
ELU/LUP/LUS
NK LU/LUP/LUS
E250 - 400T
H400T
NK250T
E250 - 400F
H400F
NK250F
NK400T/F, NK400/50% TP
ESE/SEP
NK100/70SEP
NK150-250SE/SEP
NK250/50% SEP
NK600 T,F/2
NK1000 T,F/2
H1000 F/2
Unit package
Minimum Plastic Carton
delivery binding
box
amount
strip
EURO pallet
1200 x 800
Transportation package
One-way
One-way
Pallet
pallet
pallet
weight
730 x 650 730 x 1120
(pcs.)
(pcs.)
(kg)
432
960
527 - 1170
432
Pallet
height
(cm)
50
960
527-1170
50
300
530-750
48
240
530-1060
48
360-450-630
820-910
50-55
200
710
54
760-1060
48
2*
Helvar | Data is subject to change without notice. More information at: www.helvar.com
120
(240)
93
Fully electronic
Super-imposed pulse type
Compact design
Solid metal fixing screw
Low inherent heating
High thermal resistance
Low power losses
ENEC approved*
tw 130
L-70
L-150
HI-400M
HI-400S
L-600
L-1000S 2)
70(DE) 3) -150
70(DE) 3) -400
70(DE) 3) -400
70(DE) 3) -600
70(DE) 3) -1000
35-150
35-400
35-400
35-400
35-1000
(W) -
35-150
35-400
35-400
35-400
35-400
1.8
4.6
4.6
6.5
12
198-264
198-264
198-264
198-264
198-264
198-264
170
170
170
170
170
170
60-90 /
240-270
60-90 /
240-270
60-90 /
240-270
60-90 /
240-270
60-90 /
240-270
60-90 /
240-270
100
100
100
100
100
< 1.0
(25 C; 1.8 A)
< 3.4
(25 C; 4.6 A)
< 3.3
(25 C; 4.6 A)
< 4.0
(25 C; 6.5 A)
< 6.0
(25 C; 12 A)
105
105
105
105
105
-30
-30
-30
-30
-30
130
130
160
230
430
88x34x28
92x34x28
92x38x32
92x43x36
108x55x43
1)
Weight (g)
< 1.0
(25 C; 1 A)
130
Note: Suitability for lamps refers to most common lamps acc. to EN standards. Check also lamp manufacturer information of proper
ignitor selection. Not suitable for lamps with low ignition voltage (~1 kV)
1) See also recommended combinations, dimensions and connection on page 68
2) L-1000S is not ENEC approved
3) DE means double ended lamp
Minimum delivery amount 50 pcs.
94
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
Fully electronic
Super-imposed pulse type
Compact design
Solid metal fixing screw
Low inherent heating
High thermal resistance
Low power losses
ENEC approved
tw 130
LSI-70T1
LSI-150T20
LHI-400ST10
LSI-400ST20
LSI-600T20
LSI-1000T10 2)
(W)
35-70
70(DE) 3) -150
70(DE) 3) -400
70(DE) 3) -400
70(DE) 3) -600
70(DE) 3) -1000
Metal halide 1)
(W)
35-150
35-400
35-400
35-400
35-1000
(W)
35-150
35-400
35-400
35-400
35-400
1.8
4.6
4.6
6.5
12
20
18
DIGITAL 1)
DIGITAL 1)
18
198-264
198-264
198-264
198-264
< 170
< 170
(V)
198-264
198-264
Cut-out voltage
(V)
170
170
170
170
100
<1.0
(25 C;1.8 A)
105
100
<3.0
(25 C; 4.6 A)
105
100
<3.3
(25 C; 4.6 A)
105
100
<4.0
(25 C; 6.5 A)
105
100
<6.0
(25 C; 12 A)
105
-30
-30
-30
-30
-30
Weight
130
160
160
230
460
88x34x28
92x38x32
92x38x32
92x43x36
108x55x43
2 (1.5 kV)
60-90 /
Phasing (el)
240-270
Pulses per half cycle
2
Max. load capacitance (pF) 200
<1.0
Internal losses (W)
(25 C; 1A)
Max. housing temp. (C) 105
(g)
130
Home
Prev
Next
Note: Suitability for lamps refers to most common lamps acc. to EN standards. Check also lamp manufacturer information of proper
ignitor selection.Not suitable for lamps with low ignition voltage (~1 kV)
1) See also recommended combinations, dimensions and connection on page 68
2) LSI-1000T10 is not ENEC approved.
3) DE means double ended lamp
Minimum delivery amount 50 pcs.
Helvar | Data is subject to change without notice. More information at: www.helvar.com
95
Helvar ignitors for high pressure sodium- and metal halide lamps
Ignitor
Watt 35
70
70
HI-400M
2)
HI-400S
METAL HALIDE 1)
35
70
2)
2)
2)
2)
2)
2)
2)
LHI-400ST10
2)
2)
2)
2)
LSI-400ST20
2)
2)
2)
2)
L-70
LSI-70T1
L-150
LSI-150T20
L-600
2)
2)
2)
2)
2)
2)
2)
2)
LSI-600T20
2)
2)
2)
2)
2)
2)
2)
2)
L-1000S
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
LSI-1000T10
2)
2)
2)
2)
2)
2)
2)
2)
2)
2)
Home
Prev
Next
Recommended combination
T1 Automatic cut-out 2 min
T10 Automatic cut-out 18 min
T20 Automatic cut-out 20 min
Note: Suitability for lamps refers to most common lamps acc. to EN standards. Check also lamp manufacturer information of
proper ignitor selection.
1) Not suitable for lamps with low ignition voltage (~1 kV)
2) Used combination
Dimensions
Connection
96
Ignitor
L-70
L-150
HI-400M
HI-400S
L-600
L-1000 / L-1000S
LSI-70T1
LSI-150T20
LHI-400ST10
LSI-400ST20
LSI-600T20
LSI-1000T10
A X B X C (mm)
88x34x28
88x34x28
92x34x28
92x38x32
92x43x36
108x55x43
88x34x28
88x34x28
92x38x32
92x38x32
92x43x36
108x55x43
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
Helvar | Data is subject to change without notice. More information at: www.helvar.com
97
Wiring considerations
Wire type
Ballast earthing
Maximum tc temperature
Frequent switching
Wire connections
As shown on the ballast label and the Wiring Diagram datasheets
Wire preparation
Wiring capacitance
Not advised
Not permitted
8 Newtons (typical)
Starting aid
For reliable starting (and electrical safety) all metal parts of the
fitting must be at the same electrical potential as the ballast case
Reflector position
Placing a reflector or metal plate very close to the lamp may
increase RFI emissions and cause excessive leakage current of
the fitting
See lamp standards for recommendations
Fitting components
Ensure the correct electrical ratings for the lamps are used (e.g.
500V rated lampholders are required for T5 lamps)
Ballast mounting position
Ensure that the entire length of the ballast lies against a flat
surface to ensure good heat dissipation
98
Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
Stand-by function
The stand-by function is designed specifically as a protection for the
ballast. It will switch the lamps off when an end of lifetime condition
occurs. Lamps can also fail in many other ways. As such, the exact
operating state of the ballast under other lamp fault conditions
depends on the specific failure. The ballast will not be harmed
under any normal lamp failure condition. Ballasts can be reset from
stand-by either by switching the mains supply off and then on, or by
replacing the faulty lamps.
Lamp end of lifetime
Behaviour of the ballast at end of lamp life time:
IEC 61347-2-3 17.2.
If the lamp electrical characteristics (e.g. lamp voltage) exceed
the ballast internal preset values, the ballast will recognise that
a lamp/s has reached the end of its useful operational life. The
ballast will then switch off the supply to the lamps to prevent
unnecessary stress to the circuit.
Site considerations
Home
Prev
Next
Helvar | Data is subject to change without notice. More information at: www.helvar.com
99
Wiring considerations
1. Fluorescent and HID lamp ballasts
Wire type
Push in terminals:
Screw terminals:
Wire type
Solid core or stranded conductor
Wiring insulation
According to recommendations in EN 60598
Wire cross section dimensions
Push in terminals:
0.5 - 1.0 mm
(0.5 - 1.5 mm for HID lamp ballasts)
Screw terminals:
1.5 - 3.0 mm
Wiring insulation
According to recommendations in EN 60598
Wire cross section dimensions
1.5 - 3.0 mm or 2.0 - 4.0 mm (depending upon ignitor type)
2.5 - 5.0 mm (1000 W ignitors)
Prev
Wire connections
As shown on the ignitor label and datasheet
Next
Wire preparation
Push in terminals:
Screw terminals:
Wire preparation
Strip length 7.0 mm 1 mm
Wire connections
As shown on the ballast label and the Wiring Diagram datasheets
Mineral insulated cable
Not advised
Home
100 Helvar | Data is subject to change without notice. More information at: www.helvar.com
Noise avoidance
Ensure the ballast is securely fixed within the luminaire
Fix the ballast at a minimum distance of 3mm from the side of
the fitting
Ensure that the fitting is of rigid construction (especially at the
point where the ballast is fitted)
In large fittings the ballast should be separated from the fitting
by mounting it on an aluminium plate (approx. 2 mm thick)
Mount as few ballasts as possible in one fitting
If using multiple ballasts in a fitting, ensure that the ballasts are
mounted as far as possible from each other
Site considerations
Mixed technology on the same electrical circuit
Magnetic and electronic ballasts should not be connected to the
same electrical circuit. The energy spikes produced by magnetic
ballasts may result in damage to the electronic ballasts
Miniature Circuit Breakers
Type C MCBs having trip characteristics in accordance with
EN 60898 are recommended.
Type B MCBs are not recommended due to their sensitivity. If
used, they must only be loaded to 60 % of the equivalent Type C
MCB
Home
Prev
Next
Reflector position
Situating a reflector or metal plate very close to the lamp may
increase RFI emissions and cause excessive leakage current of
the fitting
Protection against lamp rectification
Metal Halide & High-Pressure Sodium lamps can begin to
rectify as they reach the end of their operational lifetime.
This can cause excessive temperature in a fitting. As such,
it is recommended that thermal protection be fitted in these
luminaires
A thermal protection device should be fitted inside the luminaire
Helvar ballasts for Metal Halide & High-Pressure Sodium lamps
are available also with internal thermal protectors (P-types)
Use of ignitors with a timer facility also provide some protection
against lamprectification. Use in conjunction with a thermal
protector
Helvar | Data is subject to change without notice. More information at: www.helvar.com
101
I (A)
Ipeak
Ipeak
T (ms)
LL1x6-U-CC
LL1x20-U-CC
LC1x30-E-CC
LC1x30-E-DA
LC1x30-E-AN
OL1x60-E- CC
OL1x100-E-CC1
OL1x100-E-CC2
LC50-U-DX3
LL1x70-E-CC
LL1x70-E-DA
LL2x35-E-CC
Based on ICont
220
100
74
73
73
39
20
19
41
32
31
30
Based on Ipeak
220
100
74
73
73
18
13
12
41
32
31
30
Typical
inrush
current
Ipeak (A)
2.5
7.6
6.2
6.7
7
50
26
25
7
32
33
40
1/2 value
time
Calculated
energy
t (s)
45
25
25
26.4
27
270
610
690
56.0
152.0
148.0
186.0
Ipeak2t (A2s)
0.0003
0.001
0.000901
0.0011
0.0011
0.3736
0.29240
0.28890
0.00120
0.115800
0.146500
0.219800
102 Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
1x14 T5
2x14 T5
4x14 T5
1x21 T5
2x21 T5
1x24 T5, TC-L
2x24 T5, TC-L
1x28 T5
2x28 T5
1x35 T5
2x35 T5
1x36 T8, TC-L
2x36 T8, TC-L
1x39 T5
2x39 T5
1x49 T5
2x49 T5
1x54 T5
2x54 T5
1x55 T5, TC-L
2x55 T5, TC-L
1x80 T5, TC-L
3x14 T5
2x80 T5, TC-L
iDim
EL 1x14-35iDim
EL 2x14-35iDim
EL 4x14iDim
EL 1x14-35iDim
EL 2x14-35iDim
EL 1x24iDim
EL 2x24iDim
EL 1x14-35iDim
EL 2x14-35iDim
EL 1x14-35iDim
EL 2x14-35iDim
EL 1x36iDim
EL 2x36iDim
EL 1x39iDim
EL 2x39iDim
EL 1x49iDim
EL 2x49iDim
EL 1x54iDim
EL 2x54iDim
EL 1x55iDim
EL 2x55iDim
EL 1x80iDim
EL3x14iDim
EL2x80iDim
152
79
42
110
56
101
51
81
42
66
34
73
37
61
31
47
24
44
22
43
22
30
54
16
Based on Ipeak
46
38
42
46
38
57
45
46
38
46
34
45
34
45
31
45
24
44
22
43
22
26
48
12
Typical
inrush
current
Ipeak (A)
1/2 value
time
Calculated
energy
t (s)
Ipeak2t (A2s)
35
38
35
35
38
30
37
35
38
35
38
37
44
37
44
37
49
37
49
37
49
49
34
49
144,0
173,0
141,0
144,0
173,0
123,0
130,0
144,0
173,0
144,0
173,0
130,0
165,0
130,0
165,0
130,0
200,0
130,0
200,0
130,0
200,0
200,0
141,0
323,0
0,13
0,18
0,13
0,13
0,18
0,08
0,13
0,13
0,18
0,13
0,18
0,13
0,23
0,13
0,23
0,13
0,36
0,13
0,36
0,13
0,36
0,36
0,12
0,46
Typical
inrush
current
Ipeak (A)
1/2 value
time
Calculated
energy
t (s)
Ipeak2t (A2s)
Home
Prev
Next
EL-iDim-c
Lamp(s)
iDim-c
1x18W TC-DE/TE
2x18W TC-DE/TE
1x18W TC-L/F
1x24W TC-L/F
1x22W TC-T5c
1x40 W TC-T5c
2x18W TC-L/F
2x24W TC-L/F
1x26W TC-DE/TE
1x32W TC-TE
1x42W TC-TE
2x26W TC-DE/TE
2x26W TC-DE/TE
2x32W TC-TE
2x42W TC-TE
1/2x18iDim-c
1/2x18iDim-c
1/2x18/24iDim-c
1/2x18/24iDim-c
1/2x18/24iDim-c
1/2x18/24iDim-c
1/2x18/24iDim-c
1/2x18/24iDim-c
1/2x26-42iDim-c
1/2x26-42iDim-c
1/2x26-42iDim-c
1/2x26-42iDim-c
2x26-42iDim-c
2x26-42iDim-c
2x26-42iDim-c
119
63
107
82
82
57
67
47
82
67
54
43
47
37
28
Based on Ipeak
56
56
56
56
56
56
56
47
56
56
54
43
26
26
26
26
26
26
26
26
26
26
26
26
26
26
26
49
49
49
Helvar | Data is subject to change without notice. More information at: www.helvar.com
171,0
171,0
171,0
171,0
171,0
171,0
171,0
171,0
171,0
171,0
171,0
171,0
200,0
200,0
200,0
0,08
0,08
0,08
0,08
0,08
0,08
0,08
0,08
0,08
0,08
0,08
0,08
0,36
0,36
0,36
103
1 x 14 W T5
2 x 14 W T5
4 x 14 W T5
1 x 21 W T5
2 x 21 W T5
1 x 24 W T5
2 x 24 W T5
1 x 28 W T5
2 x 28 W T5
1 x 35 W T5
2 x 35 W T5
1 x 39 W T5
2 x 39 W T5
1 x 49 W T5
2 x 49 W T5
1 x 54 W T5
2 x 54 W T5
1 x 80 W T5
1 x 18 W T8
2 x 18 W T8
4 x 18 W T8
1 x 24 W TCL
2 x 24 W TCL
1 x 36 W T8/TCL
2 x 36 W T8/TCL
1 x 58 W T8
2 x 58 W T8
1 x 70 W T8
1 x 55 W TCL
2 x 55 W TCL
1 x 80 W TCL
EL-sc
EL1x14sc
EL2x14sc
EL4x14sc
EL1x21sc
EL2x21sc
EL1x24sc
EL2x24sc
EL1x28sc
EL2x28sc
EL1x35sc
EL2x35sc
EL1x39sc
EL2x39sc
EL1x49sc
EL2x49sc
EL1x54sc
EL2x54sc
EL1x80sc
EL1x18sc
EL2x18sc
EL4x18sc
EL1x24sc
EL2x24sc
EL1x36sc
EL2x36sc
EL1x58sc
EL2x58sc
EL1x70sc
EL1x55sc
EL2x55sc
EL1x80sc
Based on Ipeak
86
71
42
86
56
86
52
83
40
66
33
61
31
48
24
43
22
27
86
70
34
86
52
70
34
47
24
34
42
22
27
Typical
inrush
current
Ipeak (A)
25
31
31
25
31
25
31
25
31
31
47
31
47
31
47
31
47
47
25
31
47
25
31
31
47
31
47
47
31
47
47
104 Helvar | Data is subject to change without notice. More information at: www.helvar.com
1/2 value
time
Calculated
energy
t (s)
49
44
44
49
44
49
44
49
44
44
149
44
149
44
205
44
205
205
49
44
149
49
44
44
149
44
205
149
44
205
205
Ipeak2t (A2s)
0.26
0.35
0.35
0.26
0.35
0.26
0.35
0.26
0.35
0.35
2.43
0.35
2.43
0.35
3.37
0.35
3.37
3.37
0.26
0.35
2.43
0.26
0.35
0.35
2.43
0.35
3.37
2.43
0.35
3.37
3.37
Home
Prev
Next
1x14 W T5
2x14 W T5
3x14 W T5
4x14 W T5
4x14 W T5
1x21 W T5
2x21 W T5
1x24 W T5
2x24 W T5
3x24 W T5
4x24 W T5
1x28 W T5
2x28 W T5
1x35 W T5
2x35 W T5
1x36 W T5
2x36 W T5
1x39 W T5
2x39 W T5
1x49 W T5
2x49 W T5
1x54 W T5
2x54 W T5
1x55 W T5
2x55 W T5
1x80 W T5
2x80 W T5
EL-ngn5
EL1x14-35ngn5
EL2x14-35ngn5
EL3/4x14ngn5
EL3/4x14ngn5
EL4x14ngn5
EL1x14-35ngn5
EL2x14-35ngn5
EL1x24ngn5
EL2x24ngn5
EL3/4x24ngn5
EL3/4x24ngn5
EL1x14-35ngn5
EL2x14-35ngn5
EL1x14-35ngn5
EL2x14-35ngn5
EL1x39/36ngn5
EL2x39/36ngn5
EL1x39ngn5
EL2x39/36ngn5
EL1x49ngn5
EL2x49ngn5
EL1x54ngn5
EL2x54ngn5
EL1x55ngn5
EL2x55ngn5
EL1x80ngn5
EL2x80ngn5
Based on Ipeak
88
50
50
50
50
88
50
88
80
33
33
88
50
88
50
88
50
88
50
57
33
80
26
57
26
45
16
Typical
inrush
current
Ipeak (A)
21
34
34
34
34
21
34
21
22
47
47
21
34
21
34
21
34
21
34
23
40
23
40
23
40
36
49
1/2 value
time
Calculated
energy
t (s)
139
152
149
149
152
139
152
136
142
165
165
139
152
139
152
136
152
136
152
183
183
141
230
183
230
156
287
Ipeak2t (A2s)
0.04
0.13
1.3
1.3
0,13
0.04
0.13
0.04
0.05
2.67
2.67
0.04
0.13
0.04
0.13
0.04
0.13
0.04
0.13
0.07
0.22
0.05
0.27
0.07
0.27
0.15
0,40
Home
Prev
Next
EL-ngn
Lamp(s)
1 x 18 W T8
2 x 18 W T8
4 x 18 W T8
3 x 18 W T8
4 x 18 W T8
1 x 36 W T8
2 x 36 W T8
1 x 58 W T8
2 x 58 W T8
EL-ngn
EL1x18ngn
EL2x18ngn
EL4x18ngn
EL3/4x18ngn
EL3/4x18ngn
EL1x36ngn
EL2x36ngn
EL1x58ngn
EL2x58ngn
Based on Ipeak
74
70
36
47
37
71
37
47
24
Typical
inrush
current
Ipeak (A)
23
22
37
34
34
24
30
23
50
1/2 value
time
Calculated
energy
t (s)
131
132
193
149
149
134
152
128
136
Ipeak2t (A2s)
0.51
0.48
2.00
1.30
1.30
0.57
0.90
0.52
2.59
Typical
inrush
current
Ipeak (A)
29
29
37
1/2 value
time
Calculated
energy
t (s)
148
153
215
Ipeak2t (A2s)
0.91
0.93
2.13
EL-es
Lamp(s)
4x18 W T8
2x36 W T8
2x58 W T8
EL-ngn
EL4x18es
EL2x36es
EL2x58es
Based on Ipeak
60
58
29
Helvar | Data is subject to change without notice. More information at: www.helvar.com
105
1 x 14 W T5
2 x 14 W T5
3 x 14 W T5
4 x 14 W T5
1 x 21 W T5
2 x 21 W T5
1 x 28 W T5
2 x 28 W T5
1 x 35 W T5
2 x 35 W T5
1 x 24 W T5
2 x 24 W T5
3 x 24 W T5
4 x 24 W T5
1 x 39 W T5
2 x 39 W T5
1 x 49 W T5
2 x 49 W T5
1 x 54 W T5
2 x 54 W T5
1 x 80 W T5
2 x 80 W T5
1 x 18 W T8
2 x 18 W T8
3 x 18 W T8
4 x 18 W T8
1 x 36 W T8
2 x 36 W T8
1 x 58 W T8
2 x 58 W T8
1 x 70 W T8
2 x 70 W T8
EL-s
EL1x14-35s
EL2x14-35s
EL3/4x14s
EL3/4x14s
EL1x14-35s
EL2x14-35s
EL1x14-35s
EL2x14-35s
EL1x14-35s
EL2x14-35s
EL1x24s
EL2x24s
EL1x39/36s
EL2x39/36s
EL1x49s
EL2x49s
EL1x54
EL2x54
EL1x80s
EL1x18s
EL2x18s
EL3/4x18s
EL3/4x18s
EL1x36/40/18s
EL2x36/40s
EL1x58s
EL2x58s
EL1x70s
EL2x70s
EL-su
EL1x14-35s-u
EL2x14-35s-u
EL3/4x14s-u
EL3/4x14s-u
EL1x14-35s-u
EL2x14-35s-u
EL1x14-35s-u
EL2x14-35s-u
EL1x14-35s-u
EL2x14-35s-u
EL3/4x24s-u
EL3/4x24s-u
EL1x49s-u
EL2x49s-u
EL2x80s-u
EL3/4x18s-u
EL3/4x18s-u
EL1x36/40s-u
EL2x36/40s-u
EL1x58s-u
EL2x58s-u
-
Based on Ipeak
122
47
47
42
47
47
47
43
47
34
103
53
32
27
61
32
47
25
44
22
30
15
122
75
47
37
74
37
47
24
40
20
106 Helvar | Data is subject to change without notice. More information at: www.helvar.com
Typical
inrush
current
Ipeak (A)
17
34
34
34
34
34
34
34
34
34
17
17
47
47
17
34
34
47
34
47
34
67
17
17
34
34
17
34
34
47
34
49
1/2 value
time
Calculated
energy
t (s)
69
149
149
149
149
149
149
149
149
149
69
69
165
165
69
149
149
172
149
165
149
231
69
69
149
149
69
149
149
165
149
180
Ipeak2t (A2s)
0.16
1.30
1.30
1.30
1.30
1.30
1.30
1.30
1.30
1.30
0.16
0.16
2.67
2.67
0.16
1.30
1.30
2.77
1.30
2.67
1.30
6.74
0.16
0.16
1.30
1.30
0.16
1.30
1.30
2.67
1.30
3.17
Home
Prev
Next
1 x 9 W TC-SE
1 x 10 W TC-DE
1 x 10 W TC-DD
1 x 11 W TC-SE
1 x 13 W TC-DE/TE
1 x 16 W TC-DD
2 x 9 W TC-SE
2 x 10 W TC-DE
2 x 11 W TC-SE
2 x 13 W TC-DE/TE
1 x 18 W TC-DE/TE
2 x 18 W TC-DE/TE
1 x 21 W TC-DD
1 x 18 W TC-L/F
1 x 24 W TC-L/F
1 x 26 W TC-DE/TE
1 x 32 W TC-TE
1 x 42 W TC-TE
1 x 22 W TC-T5c
1 x 40 W TC-T5c
2 x 18 W TC-L/F
2 x 24 W TC-L/F
2 x 26 W TC-DE/TE
2 x 26 W TC-DE/TE
2 x 32 W TC-TE
2 x 42 W TC-TE
22 + 40 W TC-T5c
40 + 40 W TC-T5c
1x14W PL-R
2x14W PL-R
1x17W PL-R
2x17W PL-R
1x36TC-L
2x36TC-L
1x38TC-DD
2x38TC-DD
EL1/2x-TCs
1/2x9-13TCs
1/2x9-13TCs
1/2x9-13TCs
1/2x9-13TCs
1/2x9-13TCs
1/2x9-13TCs
1/2x9-13TCs
1/2x9-13TCs
1/2x9-13TCs
1/2x9-13TCs
1/2x18TCs
1/2x18TCs
1/2x18TCs
1/2x18-42TCs
1/2x18-42TCs
1/2x18-42TCs
1/2x18-42TCs
1/2x18-42TCs
1/2x18-42TCs
1/2x18-42TCs
1/2x18-42TCs
1/2x18-42TCs
1/2x18-42TCs
2x32/42TCs
2x32/42TCs
2x32/42TCs
2x32/42TCs
2x32/42TCs
1/2x14-17TCs
1/2x14-17TCs
1/2x14-17TCs
1/2x14-17TCs
1/2x36/38TCs
1/2x36/38TCs
1/2x36/38TCs
1/2x36/38TCs
EL1x-TCs
1x9-13TCs
1x9-13TCs
1x9-13TCs
1x9-13TCs
1x9-13TCs
1x9-13TCs
1x18TCs
1x18TCs
1x18TCs
1x18-42TCs
1x18-42TCs
1x18-42TCs
1x18-42TCs
1x18-42TCs
1x18-42TCs
1x18-42TCs
1x14-17TCs
1x14-17TCs
1x14-17TCs
1x14-17TCs
-
Based on Ipeak
34
34
34
34
34
34
34
34
34
34
35
35
35
33
33
33
33
33
33
33
33
33
33
33
33
28
33
32
33
33
33
33
33
33
33
32
Typical
inrush
current
Ipeak (A)
41
41
41
41
41
41
41
41
41
41
41
41
41
40
40
40
40
40
40
40
40
40
40
42
42
42
42
42
41
41
41
41
42
42
42
42
1/2 value
time
Calculated
energy
t (s)
182
182
182
182
182
182
182
182
182
182
181
181
181
192
192
192
192
192
192
192
192
192
192
184
184
184
184
184
190
190
190
190
184
184
184
184
Ipeak2t (A2s)
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.22
0.22
0.22
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.23
0.24
0.24
0.24
0.24
0.24
0.25
0.25
0.25
0.25
0.24
0.24
0.24
0.24
Home
Prev
Next
EP-h
Lamp(s)
1x20 HI
1x35 HI
1x50 HI
1x70 HI
EP-h
EP1x20h
EP1x35h
EP1x50h
EP1x70h
Based on Ipeak
75
52
37
32
Typical
inrush
current
Ipeak (A)
22
32
28
41
Helvar | Data is subject to change without notice. More information at: www.helvar.com
1/2 value
time
Calculated
energy
t (s)
135.0
137.0
222.0
188.0
Ipeak2t (A2s)
0.05
0.10
0.13
0.22
107
Electronic Ballasts
Magnetic Ballasts
with push in terminals
Use a 1 mm solid pin (or similar)
Home
Prev
EL-ngn
Next
Use a 1 mm solid pin (or similar) or gently twist and pull wire at the same time
EP-h
Use a Use a flat blade screwdriver
(example shown) to push down
gently on the built in push button.
108 Helvar | Data is subject to change without notice. More information at: www.helvar.com
Standard connection
(shown on product label)
Prev
Next
Option (6 wires)
Option (8 wires)
Helvar | Data is subject to change without notice. More information at: www.helvar.com
109
Cap
Sylvania
Osram
Philips
Thorn
Tungsram
GE
T26 (T8)
G13
TL
T16 (T5)
G5
TL
TC-S
G23
LYNX-S
Dulux S
PL-S
FD
Biax S
TC-SE
2G7
LYNX-SE
Dulux SE
PL-S
FD/E
Biax SE
TC - D
G 24 d
LYNX-D
Dulux D
PL-C
FD-D
Biax D
TC-DE
G 24 q
LYNX-DE
Dulux D/E
PL-C
FD-D/E
Biax D/E
TC-T
GX 24 d
LYNX-T
Dulux T
PL-T
Biax T
TC-TE
GX 24 q
LYNX-TE
Dulux T/E
PL-T
Biax T/E,QE
TC-L
2 G 11
LYNX-L,-LE
Dulux L
PL-L
2L
FD-L
Biax L
TC-DD
GR8,GR10q
2D
Biax 2D
T-R,28/30,T9
G 10 q
FC
FC
TL-E
Circline
T-R,16,T5
2GX13
FC
FC
TL 5 C
TC-F
2 G 10
LYNX-F
Dulux F
Fluorescent lamps
E27, E 40
HSL
HQL
HPL
MBF
HqLI
HqLI
HMG
E27
HQL-B
HPL-B
HMR
E27, E40
HSR-BW
HQL-R
HPL-R
MBFR
MBFR
E 27, E40
SHP-T
NAV-T
SON-T
SON-T
TCF
SON-T
HSE
E 27, E40
SHP-E
NAV-E
SON
SON-E
TCL
SON-E
HSE-I
E 27, E40
SHP/I
NAV-E
SON
Lucalox I
HST-DE
R 7 S, Fc 2
NAV-TS
SON-TD
SON-TD
E27, E 40
SHX
NAV-E
SON-H
SON-Classique
HIT
G 12
HIS-T
HQI-T
MHN-T (PG12)
MBI-T/ BOH
MBI-T
HIT
E 40
HIS-T
HQI-T
HPI-TD
MQI-T
HqMIF
MBIF
HIT-DE
R 7 S, Fc 2
HIS-TD
HQI-TS
MHN-TD HPI-TD
MBIL
HqMIS
MQI
HIT-I
E40
HQI-T
HPI-BUS
MBI-T
HIE
E27, E 40
M (E27)
HQI-E
HPI
MBI
HqMIL
MBI
HIR
E40
HQI-R
HqMIR
110 Helvar | Data is subject to change without notice. More information at: www.helvar.com
Home
Prev
Next
Control output
Motion
Detector
Constant
Light
Features
Bright Out IR Receiver
Dimming
Relay Output
Home
Page
Minisensor3
DALI *
116
DALI *
113
Dim SL-MW-DA
DALI *
117
Dim SL-MW-AN
1 - 10 V
118
Dim SL-MW-SW
Switching
Dim SS-PIR-AN
1 - 10 V
Dim SS-PIR-SW
Switching
Next
119
120
121
MIMO3
1 - 10 V
123
MIMO2
1 - 10 V
124
TK4
1 - 10 V
Prev
125
Helvar | Data is subject to change without notice. More information at: www.helvar.com
111
freedom in lighting
Multisensor (312) ,
(PIR extension)
Home
iDim Sense (316)
(Master )
RJ Style
4P4C Cable
DA
DA
DALI 1
64 mA
230 V
)+(
)-(
Prev
iDim Ballast s
Next
L
N
SW 1
com
SW 2
com
Switch
Control
iDim Sense
tc
www.helvar .com
iDim Sol o
Interface Modul e
100 - 240 V 50 - 60 Hz
40 mA
ta: 10C...50C
tc: 75C
DALI 2
32 mA
0,5...1,5
9 mm
16
DAL I 1
64 mA
+
-
DAL I 2
32 mA
+
-
DA )+(
DA )-(
iDim Solo
Switch Control
via DIGIDIM 444
DIGIDI M
Panels
1
3
1) Classroom
2) Single office
3) Open plan office
4) Corridor link
5) Corridor hold
6) Meeting room
Please refer iDim user guide for
detailed description of the iDim
modes.
112 Helvar | Data is subject to change without notice. More information at: www.helvar.com
iDim
iDim Sense (316)
iDim Sense without Fascia
7.3 mm
12.3 mm
20 mm
55 mm
25 mm
28.5 mm
21.4 mm
Home
Connections
Prev
Next
RJ Style Cable
( 4P4C )
iDim Solo
DA+
DA DALI 2
32 mA
DA (+)
DA (-)
EL-iDim Ballasts
DALI 1
64 mA
DA (+)
DA (-)
Introduction
Technical Data
DALI consumption:
Ambient temperature:
Relative humidity:
Storage temperature:
Key Features
3.0m
10 mA
10 50 C
90 % maximum, non-condensing
-25 C 75 C
60O
0.8m
0.5m
2.5m
3.5m
Helvar | Data is subject to change without notice. More information at: www.helvar.com
4.5m
113
iDim
iDim Solo (403)
Home
Connections
Prev
RJ Style 4P4C
Connector
L
N
Next
Switch-Control
Introduction
Technical Data
Mains Supply:
Protection:
2 x DALI outputs:
Ambient temperature:
Relative humidity:
Storage temperature:
Key Features
Power capability: 64 mA (DALI 1), 32 mA (DALI 2) or 96 mA when
operating in parallel
2 x DALI outputs
2 x Switch control inputs
iDim Sense connection (RJ style, 4P4C)
Mains connection
114 Helvar | Data is subject to change without notice. More information at: www.helvar.com
iDim
iDim Remote (304)
59 mm
Ch2
Ch1
OK
Ch1
110 mm
Ch2
4
Fn
21 mm
Home
Prev
H
A
Ch1
Ch2
OK
Ch1
Ch2
4
Fn
Next
B
C
D
E
F
G
J
K
A.
B.
C.
D.
E.
F.
G.
OK key
1 - 4 Scene Recall /Configuration
Function key (Fn)
Lights off ( )
H. Transmitter
I. Mode selector button
J. Battery cover
K. USB connection (Mini B)
Introduction
Technical Data
The Infra-red iDim remote control allows the user to control, modify
and configure standalone lighting applications fitted with a 316 iDim
Sense. This hand held unit is fitted with eleven buttons that control
basic functions such as raising and lowering the general light level
and selecting four pre-set scenes and off.
Power Supply:
Operating range:
Operating frequency:
Ambient Temperature:
Relative Humidity:
Storage Temperature:
Additional Features
Mountable wall bracket / desk stand included
Connects to PC for advanced lighting setup via USB cable
Helvar | Data is subject to change without notice. More information at: www.helvar.com
115
Minisensor3
Minisensor3
Luminaire mounted
Home
Connections
Prev
Minisensor3
RJ Style 4P4C
Connector
Next
iDim Solo
L
N
1
2
EL-iDim
3(DA)
4(DA)
EL-iDim
2
3(DA)
4(DA)
Introduction
Technical Data
Supply:
from iDim Solo
Ambient temperature:
0 50 C
Relative humidity:
90 % maximum, non-condensing
Storage temperature:
-10 C 70 C
IP rating 21
Electric strength
1.5 kV
Key Features
4 operating modes, configured with 303 IR-remote
1) Automatic PIR
2) PIR with manual switch ON / automatic OFF
3) PIR with constant light function
4) PIR with manual switch ON / automatic OFF, with the constant
light function
Small and compact size
100O
0.8m
85O
0.5m
5.0m
7.0m
116 Helvar | Data is subject to change without notice. More information at: www.helvar.com
4.5m
SL-MW-DA
Dim Microwave DALI Sensor
300
o 11mm
39
Fixing lugs for
bulkhead fitting
1.5
Detai
18
19
Home
Connections
Prev
Next
Sensor head
LOAD max 2A
L
N
DA+
DALI
Ballast
DA-
N
L
Introduction
Technical Data
Supply voltage
220 - 240 V AC, 50 Hz
Max load capacity
Relay Output - 2 A
Dimmed Output - 4 x DALI ballasts
Light level
200 900 Lux
Ambient temperature:
-10 35 C
Type Class II
Key Features
Time delay function
Constant light functionality
Switching with lux level sensing
Programmable using optional IR handset (p. 122)
Compatible with with Helvar DALI ballasts / drivers
2.8m
5m
8m
Helvar | Data is subject to change without notice. More information at: www.helvar.com
12m
117
SL-MW-AN
Dim Microwave 1-10 V Sensor
300
o 11mm
39
Fixing lugs for
bulkhead fitting
1.5
Deta
18
19
Home
Connections
Prev
Next
Sensor head
LOAD max 2A
L
N
C0(-)
1-10V
Ballast
C1(+)
N
L
Introduction
Technical Data
Supply voltage
220 - 240 V AC, 50 Hz
Max load capacity
Relay Output - 2 A
Dimmed Output - 4 x 1-10 V ballasts
Light level
200 900 Lux
Ambient temperature:
-10 35 C
Type Class II
Key Features
Time delay function
Constant light functionality
Switching with lux level sensing
Programmable using optional IR handset (p.122)
Compatible with with Helvar 1-10 V ballasts / drivers
2.8m
5m
8m
118 Helvar | Data is subject to change without notice. More information at: www.helvar.com
12m
SL-MW-SW
Dim Microwave Switching Sensor
300
o 11mm
39
Fixing lugs for
bulkhead fitting
1.5
Detai
18
19
Home
Connections
Prev
Next
Sensor head
LOAD
max 2A
Introduction
Technical Data
Supply voltage
Key Features
Time delay function
Switching with lux level sensing
Programmable using optional IR handset (p. 122)
2.8m
5m
8m
Helvar | Data is subject to change without notice. More information at: www.helvar.com
12m
119
SL-PIR-AN
Dim PIR 1-10 V Sensor
300
22
20
28
3
1.5
19
22
Please see page 122 for power supply unit dimensions.
Home
Connections
Prev
Next
Sensor head
LOAD max 2A
L
N
C0(-)
1-10V
Ballast
C1(+)
N
L
Introduction
The SL-PIR-AN presence detector provides automatic control
of lighting loads. The miniature size makes it ideally suited for
mounting in luminaires to provide local control of individual fittings.
It will switch incandescent, fluorescent and compact fluorescent
lighting.
Key Features
Dimming with lux level sensing
Constant light functionality
Programmable using optional IR handset (p. 122)
Compatible with with Helvar 1-10 V ballasts / drivers
Technical Data
Supply voltage
220 - 240 V AC, 50 Hz
Max load capacity
2 A INC, ELV, FL, and CFL
4 x 1-10 V ballasts
Light level
200 900 Lux
Ambient temperature:
-10 35 C
Type Class II
PIR detection area
2.8m
5m
120 Helvar | Data is subject to change without notice. More information at: www.helvar.com
SL-PIR-SW
Dim PIR Switching Sensor
300
22
20
28
3
1.5
19
22
Please see page 122 for power supply unit dimensions.
Home
Connections
Prev
Next
Sensor head
Introduction
Technical Data
Supply voltage
220 - 240 V AC, 50 Hz
Max load capacity
2 A, INC, ELV, FL, and CFL
Light level
200 900 Lux
Ambient temperature:
-10 35 C
Type Class II
Key Features
5m
Helvar | Data is subject to change without notice. More information at: www.helvar.com
121
Dim
SA-IR-PROG Dim IR Programmer
Home
Prev
Next
22.5
145
20.5
122 Helvar | Data is subject to change without notice. More information at: www.helvar.com
MIMO3
MIMO3 energy saving sensor
19
13
30
36.5
23
17
21
17
21
18
18
Home
Connections
Setup
Prev
Next
Red
Black
Adjust the rotary top shell to set the desired light level
Introduction
Technical Data
Control voltage
1-10 VDC (EN60929)
Ambient temperature:
5 55 C
Relative humidity:
80 % maximum, non-condensing
Storage temperature:
-40 C 70 C
IP rating 20
Control Range
200 to 600 lux +/- 50 lux
Viewing angle
45 average,
42-52 depending on aperture
Key features
Easy installation into the luminaire casing or fluorescent lamp
Simple setting of the constant light level
Start up at full level
Controls up to 15 Helvar electronic ballasts
Supply voltage derived from the ballast
Smooth dimming operation, 1.5 minute settling time
Compatible with Helvar EL-sc ballasts
42-52O
max. 5m
Note: Pre-assembled with T5 clip. T8 clip and panel flange also included in package
Helvar | Data is subject to change without notice. More information at: www.helvar.com
123
MIMO2
MIMO2 constant light sensor
18.0mm +0.2
0.0
0.5 1.2mm
Connections
Home
Setup
Prev
Next
Note: Take care when adjusting the rotary disc, as it is able to rotate
freely through 360O. For example, when adjusting for a darker light level,
turning the disc too far anticlockwise will result in a brighter setting
Introduction
Technical Data
Control voltage
Ambient temperature:
Relative humidity:
Storage temperature:
Key Features
Measuring Range
200 ... 600 Lux
at sensor set 2 m above surface
IP rating 20
45O
2m
0.8m
124 Helvar | Data is subject to change without notice. More information at: www.helvar.com
1.5-2.5m
TK4
TK4 modular ballast controller
140203
140202
140201
140200
Home
Connections
Prev
Next
Introduction
Technical Data
Switch Rating:
10 A (resistive) VAC
Switch Load Capacity: Up to 20 Helvar EL-sc ballasts
Ambient temperature:
Relative Humidity:
Storage Temp:
0 35 C
90 % max, non-condensing
-10 C . . . 70 C
IP Rating:
Isolation:
30
4 kV
Helvar | Data is subject to change without notice. More information at: www.helvar.com
125
T5
136
G5
L 8 D L 8 DL 1)
79
L 8 D L 8 DL 1)
79
L 8 D L 11 D
79
L 13 DL
79
(FD-H)
16mm
212
G5
288
G5
13
517
G5
14
549
24
28
849
549
1149
EL1/2x9-13TCs 2)
46
G5
EL1x14-35ngn5
EL2x14-35ngn5
EL3/4x14ngn5
EL4x14ngng5
EL1x14-35s
EL2x14-35s
EL3/4x14s
EL1x14-35s-u
EL2x14-35s-u
EL3/4x14s-u
EL1/2x9-13TCs
46
G5
EL1x14-35ngn5
EL2x14-35ngn5
EL1x14-35s
EL2x14-35s
EL1x14-35s-u
EL2x14-35s-u
EL1/2x9-13TCs
46
G5
EL1x24ngn5
EL2x24ngn5
EL3/4x24ngn5
EL1x24s
EL2x24s
EL3/4x24s-u
46
G5
EL1x14-35ngn5
EL2x14-35ngn5
EL1x14-35s
EL2x14-35s
EL1x14-35s-u
EL2x14-35s-u
EL1/2x9-13TCs
46
T5
21
Standard
electronic ballast
48 EL1x14sc
EL2x14sc
EL4x14sc
50
48
50
EL1x24sc
48 EL2x24sc
28
48 EL1x35sc
EL2x35sc
50
38
EL1x14-35iDim
EL2x14-35iDim
28
38
EL1x39iDim
EL2x39iDim
28
38
EL1x49iDim
EL2x49iDim
28
38
EL1x54iDim
EL2x54iDim
28
38
EL1x80iDim
EL2x80iDim
28
46
46
G5
EL1x49ngn5
EL2x49ngn5
EL1x49s
EL2x49s
EL1x49s-u
EL2x49s-u
46
46
G5
EL1x80ngn5
EL2x80ngn5
EL1x80s
EL2x80s-u
1)
Home
EL1x14-35iDim
EL2x14-35iDim
EL1x39/36ngn5
EL2x39/36ngn5
EL1x39/36s
EL2x39/36s
1449
28
38
50
G5
80
EL1x14-35iDim
EL2x14-35iDim
EL1x28sc
EL2x28sc
48
849
G5
38
Magnetic Ballast
(230 V, 50 Hz)
Next
50
39
1149
28
28
G5
54
EL1x14-35iDim
EL2x14-35iDim
EL3x14iDim
EL4x14iDim
EL1x24iDim
EL2x24iDim
1449
EL1x54ngn5
EL2x54ngn5
EL1x54s
EL2x54s
38
38
35
1449
EL1x21sc
EL2x21sc
Digital DALI
electronic ballast
Prev
EL1x14-35ngn5
EL2x14-35ngn5
EL1x14-35s
EL2x14-35s
EL1x14-35s-u
EL2x14-35s-u
49
Controllable
electronic ballast
Page
Cap
Page
Length
(mm)
Page
Page
Lamp type
EL1x39sc
48 EL2x39sc
48 EL1x49sc
EL2x49sc
50
EL1x54sc
48 EL2x54sc
48
50
EL1x80sc
Types printed BOLD are ENEC approved combinations. Other combinations mentioned are tested and recommended by Helvar.
Please check CE compatibility and EEI classification from ballast datasheets.
1) Approved to EN 61347-2-8
2) For a combination of two 8 W T5-lamps
Note: All combinations can be used as well with Eco-lamps.
126 Helvar | Data is subject to change without notice. More information at: www.helvar.com
T8
(FD-E)
26mm
18
590
G13
T8
36
1200
G13
Standard
electronic ballast
EL1x18s
EL2x18s
EL3/4x18s
EL3/4x18s-u
53
EL1x18ngn
EL2x18ngn
EL3/4x18ngn
EL4x18ngn
52
EL1x36/40/18s
EL2x36/40s
EL1x36/40s-u
EL2x36/40s-u
EL1x36ngn
EL2x36ngn
EL1x18-42TCs
58
1500
EL1x58s
EL2x58s
EL1x58s-u
G13 EL2x58s-u
EL1x58ngn
EL2x58ngn
EL1x36sc
EL2x36sc
40
52
EL1x36iDim
EL2x36iDim
72
L 36 A-T
L 36 A-K
L 40 A-L
L 40 A-C
30
L 36 A-TK
L 36 TL2
L 36 TL3
L 36 TL4
53
EL1x58sc
EL2x58sc
40
52
EL1x70s
EL2x70s
72
Home
L 58 TL2
L 58 TL3
L 58 TL4
L 58 TL4 - 220mm
L 58 A-S
L 65 A-P
L 58 A-K
L 58 A-T
L 58 A-TK
73
Prev
Next
73
L 15 A
L 15 A-P
L 15 TL3
72
G13
L 16 D
L 16 DL
72
G13
L 15 A-P
72
L 30 A
L 30 A-P
L 30 TL2
72
15
450
G13
16
720
23
970
30
900
G13 EL2x32/42TCs
32 3)
1200
G13 EL2x49s
1047
53
L 18 A-L
L 18 A-K
L 18 A-T
L 2x18 A-L
L 2x18 A-L
L 20 A-P
L 26 TS5 - 100mm
L 18 TL2
L 18 TL3
L 18 TL4
L 75 A-S 2)
L 70 TL4 1)2)
G13
38
40
Magnetic Ballast
(230 V, 50 Hz)
1500
970
EL1x18sc
EL2x18sc
EL4x18sc
Digital DALI
electronic ballast
40
70
36
Controllable
electronic ballast
Page
Length Cap
(mm)
Page
Page
Lamp type
Page
EL1x49s
EL1x36/40/18s
EL2x36/40s
EL1x36/40s-u
EL2x36/40s-u
EL1x36/40/18s
G13 EL2x36/40s
EL1x70sc
57
-
EL1x36sc
EL2x36sc
L 36 TL2
L 36 TL4
L 36 A-K
L 36 A-T
L40 A-L
L40 A-C
L 36 TL3
L 36 A-TK
72
Types printed BOLD are ENEC approved combinations. Other combinations mentioned are tested and recommended by Helvar.
Please check CE compatibility and EEI classification from ballast datasheets.
1) Approved to EN 61347-2-8
2) 240 V, 50 Hz
3) Not T8 eco lamp
Helvar | Data is subject to change without notice. More information at: www.helvar.com
127
T5 circular
22
2GX13
40
2GX13
55
2GX13
22
32
Circline
(FD-E)
40
Magnetic Ballast
(230 V, 50 Hz)
Page
Cap
Standard
electronic ballast
G10q
L 30 TL2
L 30 A
78
G10q
L 32 TB2
78
EL1/2x18-42TCs
EL1x18-42TCs
EL1/2x18-42TCs
EL1x18-42TCs
EL2x32/42TCs1)
EL1x55ngn5
EL1x55s
Controllable
electronic ballast
57
EL1x39sc
EL2x39sc
- EL1x55sc
G10q
TC-DD
2D-lamp GR8,
for magnetic
ballast only
GR10q, for
electronic ballast
or magnetic with
external starter
10
16
G13
EL1/2x9-13TCs
GR10q
EL1x9-13TCs
EL1/2x9-13TCs
GR8, GR10q EL1x9-13TCs
EL1/2x18/24iDim-c
31
41
EL1/2x18/24iDim-c
-
31
57
Mod-U-line
(FU-E)
40
Digital DALI
electronic ballast
Page
Page
Lamp type
Page
L 36 TL2
L 36 TL3
L 36 TL4
L 36 A-K
L 36 A-T
L40 A-L
L40 A-C
L 36 A-TK
L 36 TL2
L 36 TL3
L 36 TL4
L40 A-L
L40 A-C
L 36 A-K
L 36 A-T
L 36 A-TK
Home
Next
57
57
L16 D 2)
L16 DL
78
EL1/2x18-42TCs
38 GR8, GR10q
EL1/2x36/38TCs
57
57
L18 TL2
L18 TL3
L20 A-P
L18 A-L
L18 A-T
L18 A-K
L18 TL4
L26S
L36 TL2
L36 TL3
L36 TL4
L40 A-C
L36 A-K
L36 A-T
L36 A-TK
78
78
Types printed BOLD are ENEC approved combinations. Other combinations mentioned are tested and recommended by Helvar.
Please check CE compatibility and EEI classification from ballast datasheets.
1) For a combination of one 22W and one 40 W circular lamp
2) GR8 not ENEC approved
128 Helvar | Data is subject to change without notice. More information at: www.helvar.com
Prev
Standard
electronic ballast
Controllable
electronic ballast
Digital DALI
electronic ballast
TC-L
(FSD-E)
18
24
26
28
36
40
55
80
2G11
2G11
2GX11
2GX11
2G11
2G11
2G11
2G11
EL1/2x18-42TCs
EL1x18-42TCs
56
EL1x36/40/18s
EL1x36/40s-u
60
60
EL1/2x18-42TCs
EL1x18-42TCs
56
EL1x24ngn5
EL2x24ngn5
EL3/4x24xngn5
EL1x24s
EL2x24s
EL3/4x24s-u
EL1x14-35s
EL2x14-35s
EL1x14-35s-u
EL2x14-35s-u
EL1x14-35s
EL2x14-35s
EL1x14-35s-u
EL2x14-35s-u
EL1x39/36ngn5
EL2x39/36ngn5
EL1x39/36s
EL2x39/36s
EL1/2x36/38TCs
EL1/2x18-42TCs
EL1x18-42TCs
EL2x36ngn
EL1x36/40/18s
EL1x36/40s-u
EL2x36/40s
EL2x36/40s-u
EL1/2x18-42TCs
EL1x18-42TCs
EL1x55ngn5
EL2x55ngn5
EL1x55s
EL2x55s
EL1x80ngn5
EL2x80ngn5
EL1x80s
EL2x80s-u
55
- EL1/2x18/24iDim-c
EL1x24sc
EL2x24sc
41
EL1x24iDim
EL2x24iDim
EL1/2x18/24iDim-c
60
60
Magnetic Ballast
(230 V, 50 Hz)
Page
Cap
Page
Page
Lamp type
Page
L26 TS5-100mm
L18 TL2
L18 TLB2
L18 TL3
32 L18 TL4
L20 A-P
L18 A-K
L18 A-T
L18 A-L
77
L26 TS5-100mm
L18 TL2
31 L18 TL3
L18 TL4
L20 A-P
32 L18 A-K
L18 A-T
L18 A-L
77
Home
EL1x14-35iDim 1)
EL2x14-35iDim 1)
60
31
Prev
EL1x14-35iDim 1)
EL2x14-35iDim 1)
31
41
EL1x36iDim
EL2x36iDim
L36 TL2
L36 TL3
L36 TL4
31
L40 A-C
L36 A-T
L36 A-K
L36 A-TK
41
EL1x39iDim
EL2x39iDim
31
60
55
60
EL1x36sc
56 EL2x36sc
60
60
EL1x39sc
EL2x39sc
Next
77
56
55
60
EL1x55sc
EL2x55sc
41 EL1x55iDim
EL1x80sc
41
EL2x55iDim
55
60
60
EL1x80iDim
EL2x80iDim
31
31
Types printed BOLD are ENEC approved combinations. Other combinations mentioned are tested and recommended by Helvar.
Please check CE compatibility and EEI classification from ballast datasheets.
1) Dimming range 3-100 %
Helvar | Data is subject to change without notice. More information at: www.helvar.com
129
Cap
TC-F
18
FSS-E 24
36
TC-S
FSD-I
TC-SE
2G10
2G10
2G10
Standard
electronic ballast
EL1/2x18-42TCs
EL1x18-42TCs
EL1x36/40/18s
EL1x36/40s-u
56
61
EL1x24s
EL2x24s
EL3/4x24s-u
EL1/2x18-42TCs
EL1x18-42TCs
EL1x24ngn5
EL2x24ngn5
EL3/4x24xngn5
61
EL1x39/36s
EL2x39/36s
61
EL1/2x36/38TCs
EL1/2x18-42TCs
EL1x39/36ngn5
EL2x39/36ngn5
Controllable
electronic ballast
56 EL1x24sc
EL2x24sc
-
EL1x36sc
56
EL2x36sc
-
Digital DALI
electronic ballast
Magnetic Ballast
(230 V, 50 Hz)
L18 TL2
L18 TL3
L18 TL4
EL1/2x18/24iDim-c 32 L20 A-P
L18 A-L
L18 A-K
L18 A-T
L18 TL2
L18 TL3
L18 TL4
L26 TS5-100mm
41 EL1/2x18/24iDim-c 32 L26 TS5-105mm
L20 A-P
L18 A-L
L18 A-T
L18 A-K
EL1x36iDim
41
EL2x36iDim
L36 TL2
L36 TL3
L36 TL4
- L36 A-T
L36 A-TK
L36 A-K
L40 A-C
L11 D
L11 DL 1)
L11 D
L11 DL 1)
L11 D
L11 DL 1)
L11 D
L11 DL 1)
G23
G23
G23
11
G23
2G7
EL1/2x9-13TCs
EL1x9-13TCs
57
11
2G7
EL1/2x9-13TCs
EL1x9-13TCs
57
10
G24d-1
13
G24d-1
18
G24d-2
26
G24d-3
Page
Page
ILCOS
Page
Lamp type
Page
Home
-
Prev
79
79
79
79
FSD-E
TC-D
FSQ-I
L13 D
L13 DL 1)
L13 D
L13 DL 1)
L18 D
L18 TLD-100mm
L18 DL
L18 TL2
L18 TL3
L26 S-100mm
L26 TS5-105mm
L26 TS5-100mm
L20 A-P
L18 A-L
L18 A-K
L18 A-T
L18 TL4
78
78
78
78
Types printed BOLD are ENEC approved combinations. Other combinations mentioned are tested and recommended by Helvar.
Please check CE compatibility and EEI classification from ballast datasheets.
1) Approved to EN61347-2-8
130 Helvar | Data is subject to change without notice. More information at: www.helvar.com
Next
TC-DE
Cap
Standard
electronic ballast
10
G24q-1
EL1/2x9-13TCs
EL1x9-13TCs
58
13
G24q-1
EL1/2x9-13TCs
EL1x9-13TCs
58
18
G24q-2
EL1/2x18TCs
EL1x18TCs
58
EL1/2x18iDim-c
32
26
G24q-3 EL1x18-42TCs
58
EL1/2x26-42iDim-c
EL2x26-42iDim-c
32
Controllable
electronic ballast
Digital DALI
electronic ballast
Page
Page
ILCOS
Page
Lamp type
Magnetic Ballast
(230 V, 50 Hz)
Page
L18 D
L18 TLD-100mm
FSQ-E
TC-T
EL1/2x18-42TCs
EL2x32/42TCs
18 GX24d-2
Home
FSM-I
L18 TL2
L18 TL3
L26 TS5-105mm
L26 TS5-100mm
26 GX24d-3
TC-TE
FSM-E
13 GX24q-1
EL1/2x9-13TCs
EL1x9-13TCs
59
18 GX24q-2
EL1/2x18TCs
EL1x18TCs
59
EL1/2x18iDim-c
32
26 GX24q-3
EL1/2x18-42TCs
EL2x32/42TCs
59
EL1/2x26-42iDim-c
EL2x26-42iDim-c
32
59
EL1/2x26-42iDim-c
EL2x26-42iDim-c
32
59
EL1/2x26-42iDim-c
EL2x26-42iDim-c
32
EL1/2x26-42iDim-c 2) 32
EL1/2x18-42TCs
32 GX24q-3 EL1x18-42TCs
EL2x32/42TCs
EL1/2x18-42TCs
42 GX24q-4 EL1x18-42TCs
EL2x32/42TCs
PL-R
57 GX24q-4
EL1/2x18-42TCs
EL1x18-42TCs
59
14 GR14q-1
EL1/2x14/17TCs
EL1x14/17TCs
59
17 GR14q-1
EL1/2x14/17TCs
EL1x14/17TCs
59
Prev
Next
Types printed BOLD are ENEC approved combinations. Other combinations mentioned are tested and recommended by Helvar.
Please check CE compatibility and EEI classification from ballast datasheets.
1) Approved to EN61347-2-8
2) UIN > 220 V , Ta > 18 OC
Helvar | Data is subject to change without notice. More information at: www.helvar.com
131
Home
Prev
Next