IDR-C LCT

Local Craft Terminal Application


(Version 02.09.02)
Users Manual

Manual Code: GDC-001/75


Manual Edition: 4

INTRACOM TELECOM, 2006. All rights reserved.


All copyright, intellectual and industrial rights in this document and in the technical knowledge it contains
are owned by INTRACOM TELECOM and/or their respective owners.
This document is made available to the end users only for their internal use.
No part of this document nor any data herein may be published, disclosed, copied, reproduced,
redistributed by any form or means, electronically or mechanically, or used for any other purpose
whatsoever without the prior written approval of INTRACOM TELECOM.
Information as well as drawings and specifications contained in this document are subject to change
without prior notice.
All trademarks and copyrights mentioned herein are the property of INTRACOM TELECOM and/or their
respective owners.
Any rights not expressly granted herein are reserved.
Printed in Greece.
INTRACOM S.A. TELECOM SOLUTIONS
19,7 km Markopoulou Ave., 19002 Peania, Athens, Greece,
Tel: (+30 210) 66 79 000, Fax: (+30 210) 66 79 001, http://www.intracom.com

IDR-C_LCT_UserManual_04

IDR-C LCT User Manual

Table of Contents
Chapter 1: Introduction.......................................................................................................................... 1

About this Document.............................................................................................1


Target Audience....................................................................................................1
Chapter 2: About IDR-C LCT ................................................................................................................. 2
Chapter 3: Basic Guidelines.................................................................................................................. 4

Screen Terminology..............................................................................................4
Conventions..........................................................................................................6
Common Actions...................................................................................................7
Chapter 4: Getting Started..................................................................................................................... 8

Installing the Management Application (IDR-C MASTER) ....................................9


Installing the Manufacturer Driver and creating a dial-up Connection to the IDR-C
(Automatic Procedure) ........................................................................................10
Connecting the Local Craft Terminal to the IDR-C..............................................16
Launching the Application...................................................................................17
Upgrading the Application...................................................................................18
Getting connected to the IDR-C ..........................................................................19
Setting the IDR-C Clock......................................................................................22
Configuring the IDR-C (Procedure Overview).....................................................23
Logging out .........................................................................................................24
Chapter 5: Configuring the IDR-C....................................................................................................... 25

Setting the Transmission/Reception Channel .....................................................25


Setting the transmitted Power .............................................................................26
Setting the RSSI Alarm Threshold ......................................................................27
Setting the ODU Temperature Alarm Threshold .................................................28
Enabling the ATPC Feature ................................................................................29
Deactivating the LOS Alarm for the unconnected Tributaries .............................30
Setting the Link Identification Number ................................................................31
Changing the Ethernet Communication ..............................................................32
Changing the IDR-C Capacity.............................................................................33
Changing the IDR-C Modulation .........................................................................33
Chapter 6: Monitoring the IDR-C......................................................................................................... 34

Monitoring the IDR-C Configuration ....................................................................34


Monitoring the Radio Measurements and Other ODU Information .....................36
Monitoring the IDR-C Version .............................................................................38
Optimizing the Link .............................................................................................40
Monitoring the Ethernet Link ...............................................................................41
Chapter 7: Monitoring the IDR-C Alarms ........................................................................................... 42

ODU Alarms........................................................................................................44
Framer/Modem/CI Alarms...................................................................................47
Mux Alarms.........................................................................................................48
Power Supply Alarms..........................................................................................49
Tributaries/Service Channels Alarms..................................................................50
Ethernet Alarms ..................................................................................................50
User Alarms Inputs/Outputs................................................................................51
i

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Monitoring the History of Alarms ......................................................................................... 52


Changing the Alarms Attributes .......................................................................................... 55
Chapter 8: Service Calls ...................................................................................................................... 60

Changing the Station Call Id for a Service Call ...................................................60


Performing a Service Call ...................................................................................61
Chapter 9: Loopbacks, Performance Monitoring & Other Tests ..................................................... 62

Changing the Transmission and/or Reception Path............................................62


Loopbacks ..........................................................................................................64
Monitoring the Performance of the RF Link ........................................................67
Enabling the AIS Transmission at the Tributaries Outputs..................................69
Imposing SinCos Demodulation..........................................................................69
Chapter 10: Upgrading the IDR-C Firmware ...................................................................................... 70
Annex A: Installing the Manufacturer Driver at the LCT and creating a dial-up Connection to the
IDR-C (Manual Procedure) ................................................................................................................... 72

Installing the Manufacturer Driver (Win 2000, XP).............................................................. 73


Creating a dial-up Connection to the IDR-C........................................................................ 81

Creating a dial-up Connection to the IDR-C (Win 2000) .....................................81


Creating a dial-up Connection to the IDR-C (Win XP) ........................................91
Annex B: Changing the Station Name, the Link Name and the Station IP Address.................... 102

IDR-C IP Addressing.........................................................................................102
Finding out the IP Address of your Station........................................................103
Changing the Station Name, the Link Name and the IP Address of your Station
..........................................................................................................................104
Annex C: Example of Router Configuration .................................................................................... 108
Annex D: Default Alarms Attributes ................................................................................................. 110

1+0 Topology ....................................................................................................110


1+1 Topology ....................................................................................................111
Annex E: Changing the IDR-C Capacity and Modulation (for the advanced User only) ............. 112

Downloading the required Files to the CMS Unit ..............................................116


Updating the ODU Version ...............................................................................118

ii

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Chapter 1: Introduction
About this Document
This document is a User Manual for INTRACOMs IDR-C LCT (Local
Craft Terminal).
The document informs the user how to use the LCT to configure and
monitor the IDR-C.
The document enables the audience that reads this manual to get
familiar with the LCT and its operation.

Target Audience
This manual is intended for Radio Technicians with experience in the
operation of Radio Telecommunication Systems.

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Chapter 2: About IDR-C LCT


General

You can use the IDR-C LCT to easily configure and monitor the IDR-C
at the local and the remote station. The user-friendly GUI of the
application gives you the possibility to perform all the essential
procedures concerning the configuration and monitoring of the IDR-C
stations.
Furthermore, you can use the LCT to type the appropriate IP
addresses, to get connected, to monitor and configure up to 10
stations (i.e. 5 radio links) as shown in the following figure:
5

IDR-C

IDR-C
1

IDR-C

IDR-C

...

IDR-C
8

IDR-C
10

LCT

Even if the IDR-C are interconnected as shown in the figure below, the
total number of stations you can configure and monitor is still 10 (i.e. 5
links).
2

IDR-C

IDR-C
3

IDR-C

IDR-C
9

IDR-C
1

IDR-C
5

LCT
IDR-C

IDR-C
4

IDR-C
7

IDR-C
8

10

Note: Each time you can monitor and configure only a pair of IDR-C
systems. Always consider as Home IDR-C the system of the pair
closest to the LCT (yet not necessarily physically connected to it).
IDR-C ports

The IDR-C has two asynchronous RS-232 ports (NMS1 and NMS2)
with baud rate 57600 bit/s for the connection of the LCT and the NMS
and one virtual synchronous serial port (over the RF link). All three
ports run RIP v2 and active PPP with PPP MTU size 400 bytes.
Continued on next page

IDR-C_LCT_UserManual_04

IDR-C LCT User Manual

About IDR-C LCT, Continued


System files

In the CMS unit of the IDR-C the following files that you may need
while working with the LCT of the IDR-C are stored:
alrm.nme & alrm.attr
boot.sys
config.sys
idrc_xxx.bin (where xxx is the version of the file)
idrc_xxx.mib (where xxx is the version of the file)
system.ini
Important Note: You are recommended to treat the aforementioned
files with extreme care, only when required and provided you are an
experienced user!

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Chapter 3: Basic Guidelines


Screen Terminology
Menu, Tab

Tab
Menu

When you click a tab, you open the corresponding tabbed sheet.
Example: When you click ODU (and provided you are connected), the
ODU tabbed sheet appears:

Box,
Drop-down
list,
Alarm
indication

Box

Drop-down
list

Alarm
Indication

Continued on next page

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Screen Terminology, Continued


Group-box,
Option
button,
Command
button

Groupbox
Option
button

Command
button

Status bar

Status
bar
Local
Station
IP Address

Remote
Station
IP Address

IDR-C
Clock

Your PC
Clock

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Conventions
Bold fonts

In the document the bold fonts denote names of the following:


Tabbed sheet
Group-box
Drop-down list
Command button
Menu
Menu command
Box
Indication
Example: In the Radio Transmitter Power group-box, click EDIT.

Note: We also use bold fonts to emphasize something.


Italic fonts

In the document, the italic fonts denote message text or text you type.
Example: In the File name box, type alrm.attr and click Save.

IDR-C_LCT_UserManual_04

IDR-C LCT User Manual

Common Actions
Save
configuration

After each configuration modification you make, on the System menu,


point to Configuration, Home or Remote and select Save if you want
to save the configuration of the local or the remote station respectively.

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Chapter 4: Getting Started


Getting
started

To get started, follow the steps below:


Step
1
2

Action
Install the management application (IDR-C MASTER) in the
Local Craft Terminal (page 9).
Install the manufacturer driver in the Local Craft Terminal
and create a dial-up connection between the Local Craft
Terminal and the IDR-C of the station (page 9).
NOTE

3
4
5
6
7
8
9
Special case:
IDR-C
connected to
a router

Through the creation of the dial-up connection, the


IDR-C assigns the LCT an IP address equal to the
IDR-C station IP address + 1 (e.g. if the IDR-C
station IP address is the 192.168.59.37, the LCT
IP address will be the 192.168.59.38).

Connect the Local Craft Terminal to the IDR-C of the station


(page 16).
Change the IP address of the station (page 102, Annex B:
Changing the Station Name, the Link Name and the Station
IP Address).
Repeat steps 2, 3 and 4 for all the IDR-C stations.
Launch the IDR-C MASTER (page 17).
Get connected to the IDR-C you want to configure (page
19).
Set the IDR-C clock (page 22).
Proceed to the configuration of the IDR-C (page 23).

You can connect the NMS1 or NMS2 port of the IDR-C to an


asynchronous serial interface of a router but you should configure the
router serial interface baud rate fixed at 57600 bit/s and assign the
router interface an IP address in the same subnet as the IDR-C which
is not used in the IDR-C network.
Example: If the IP address of the IDR-C is 192.168.59.5, assign the IP
address 192.168.59.253 to the router serial interface (if you assign the
IP address 192.168.59.6 to the router interface, the RIP will be
deactivated for this port as the IDR-C considers it is an LCT and not a
router port thus deactivating RIP transmissions).
Find an example of a router configuration on page 108, Annex C:
Example of Router Configuration.
NOTE

The only route the router needs to advertise towards the IDR-C
stations is the default route. Please note that each station
routing table can store up to 10 station routes (IDR-C stations)
and one default route.

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Management Application (IDR-C MASTER)


Hardware and
software
requirements

To get connected to the IDR-C you want to monitor/configure you


should fulfill the following platform requirements:
SP4 for Windows 2000
SP1 or SP2 for Windows XP
Screen resolution 1024x768
Serial port RS-232 with port speed 57600 bit/s

Installation
procedure

To install the application, follow the steps below:


Step
1
2
3

Action
Insert the IDR-C Operation CD-ROM in the disk drive.
Click Welcome.
In the Main Menu click Install Link Management (IDR-C
MASTER). The following window appears:

To install the application, follow the wizard instructions.

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Manufacturer Driver and creating a dial-up


Connection to the IDR-C (Automatic Procedure)
Why to install
the
manufacturer
driver

You need to install the manufacturer driver at your LCT because


during the installation a virtual modem is created making possible the
exchange of IP packets (needed by the LCT management application
which is IP based) through the RS-232 ports of the LCT and the IDRC.

Automatic
Procedure

To install the manufacturer driver in the Local Craft Terminal and


create a dial-up connection between the Local Craft Terminal and the
IDR-C of the station, follow the steps below taking into consideration
the following two Notes:
NOTE
NOTE

Step
1
2
3
4
5

Before proceeding to the automatic procedure, make sure the


IDR-C and the LCT are not connected.
In case of problems with the automatic procedure described
below, refer to Annex A: Installing the Manufacturer Driver at the
LCT and creating a dial-up Connection to the IDR-C (Manual
Procedure) on page 72.

Action
Insert the IDR-C Operation CD-ROM in the disk drive.
Click Welcome.
In the Main Menu point to the Install Driver & Create Dialup Connection arrow.
In the submenu that appears click Win2K or Windows XP
depending on the Windows version of your LCT.
In the submenu that appears click Automatic Installation.
The following window appears:

Continued on next page

10

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Manufacturer Driver and creating a dial-up


Connection to the IDR-C (Automatic Procedure), Continued
Automatic Procedure (continued)

Step
6

Action
Click Install. The following window appears:

Select the Dont detect my modem; I will select it from a


list check box and click Next. The following window
appears:

Continued on next page

11

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Manufacturer Driver and creating a dial-up


Connection to the IDR-C (Automatic Procedure), Continued
Automatic Procedure (continued)

Step
8

Action
Select the manufacturer and model of your modem and click
Next:

In the window that appears, select an available


communication port (e.g. COM1) and click Next:

Continued on next page

12

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Manufacturer Driver and creating a dial-up


Connection to the IDR-C (Automatic Procedure), Continued
Automatic Procedure (continued)

Step
10

Action
In the window that appears, click Yes (if you have Windows
2000) or click Continue Anyway (if you have Windows XP)
to continue the installation:

Windows 2000

Windows XP
Continued on next page

13

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Manufacturer Driver and creating a dial-up


Connection to the IDR-C (Automatic Procedure), Continued
Automatic Procedure (continued)

Step
11

Action
When the installation is completed, the following window
appears. Click Finish.

Continued on next page

14

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Manufacturer Driver and creating a dial-up


Connection to the IDR-C (Automatic Procedure), Continued
Automatic Procedure (continued)

Step
12

Action
In the window that appears, click OK:

The following window appears:

Continued on next page

15

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Manufacturer Driver and creating a dial-up


Connection to the IDR-C (Automatic Procedure), Continued
Automatic Procedure (continued)

Step
13
14

Action
Click Reboot now.
After the rebooting completion, the following shortcut icon
appears on your desktop:

Windows 2000

15

16

Windows XP
Double-click the shortcut icon. The following window
appears:

After the completion of the process, the following icon in the


circle appears in the status bar:

Connecting the Local Craft Terminal to the IDR-C


Connection

To connect the Local Craft Terminal to the IDR-C, follow the steps
below:
Step
1
2

16

Action
Plug the one end of the cable into the NMS1 or the NMS2
receptacle of the IDR-C.
Plug the other end of the cable into the appropriate DB9
receptacle of the Local Craft Terminal.

IDR-C_LCT_UserManual_04

IDR-C LCT User Manual

Launching the Application


Launching the
application

To launch the application, double-click the application icon:

The Main Window of the application appears:

17

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Upgrading the Application


Version of the
application

To find out the version of your currently installed software application,


in the menu bar click About:

The following window appears:

Upgrading the
Application

18

To upgrade the application, replace the old LCT_IDR_C.exe file with


the new one.

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Getting connected to the IDR-C


Procedure

To get connected to the IDR-C, follow the steps below:


Step
1
2

Action
Open the SYSTEM tabbed sheet.
In the WAN-LAN Connections group box, from the Home
IDR drop-down list select or type the IP address of the
IDR-C you want to get connected to.

Note: All the IP addresses of the Home IDR drop-down list


are stored in the last_ip.nmt file in the same folder with the
management application. Do not delete this file otherwise
you will lose the history of the IP addresses you have
been connected to.
Continued on next page

19

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Getting connected to the IDR-C, Continued


Procedure (continued)

Step
3

Action
Click Connect. When you get connected, the box of the
connection between the Host LCT and the Home IDR
becomes green and the message Connected appears:

Note 1: If the IDR-C of the local station is connected to the


IDR-C of the remote station through an RF link or through
the management channel, the box of the connection
between the Home IDR and the Remote IDR becomes
green and the message Connected appears.
Note 2: If the following message appears, the IDU cannot
communicate with the ODU.

In this case, follow the steps below:


Step
1
2
3
4

Action
Press the reset button RST on the IDU front
panel to reset the IDU.
Open the ODU tabbed sheet.
Click Reset ODU to reset the ODU.
Wait for about 35 seconds for the
communication between the IDU and the
ODU to be established.
Continued on next page

20

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Getting connected to the IDR-C, Continued


Getting
connected to
an IDR-C in a
chain of 10
stations

You can use your LCT and get connected to an IDR-C even if your
LCT is not physically connected to it. Supposing in the example below
you want to configure and monitor the IDR-C 3 and the IDR-C 4.
Perform the procedure mentioned before selecting or typing the IP
address of the IDR-C 3 from the Home IDR drop-down list. In this
case, your local station will be the IDR-C 3 and your remote station will
be the IDR-C 4.
5

IDR-C

IDR-C
1

IDR-C

IDR-C
2

...

IDR-C
8

IDR-C
9

10

LCT

Note: You can configure and monitor up to 10 stations or else 5 radio


links. For more information, see also page 2.

21

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Setting the IDR-C Clock


Info

With this setting, you synchronize the IDR-C clock to the LCT clock. It
is important to proceed to this setting so that the time of the
alarms at the alarm history list will be correct.

When to make
the setting

Set the IDR-C clock in the following cases:


When you configure the IDR-C for the first time
At the periodical maintenance of the station
If the IDR-C shuts down

Procedure

To set the IDR-C clock, on the System menu click Set Time. In the
status bar, the System Time becomes equal to the PC Time.

22

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Configuring the IDR-C (Procedure Overview)


To configure the IDR-C, follow the steps below:
If, during the configuration or the operation of the IDR-C, you
need to extract the Power Supply Unit or the
Framer/Modem/CI Unit, make sure you only loosen and
not completely extract the Allen screw (shown with the arrow in the
figure below)! If, by mistake, you completely extract the Allen screw,
you will harm the right placement of the special metallic sheets and
thus the passive system thermal loss!

Step
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15

Action
Set the transmission/reception channel (page 25).
Set the transmitted power (page 26).
Deactivate the LOS alarm for the unconnected tributaries
(page 30).
Set the link identification number (page 31).
In case of 1+1 topology, repeat steps 1,2 and 4 for the
second ODU.
Save the configuration you made (page 7).
Repeat steps 1 to 6 at the remote station.
Align the antennas of the two stations.
After the establishment of the link between the two stations,
proceed to the optimization of the link to achieve max RSSI
level (page 38).
Set the RSSI and ODU temperature alarms thresholds for
both the local and remote station (optional, pages 27 and
28).
Open the System tabbed sheet and confirm the link settings
for both the local and the remote station (page 34).
Set the ATPC level and enable the ATPC feature (optional,
page 29).
Open the different tabbed sheets and check if there are any
alarm signals (page 42).
Save the modifications you made (page 7).
Log out of the application (page 24).

23

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Logging out
Prerequisites

Before logging out of the application, make sure that you have
saved all your changes!

Logging out

To log out of the application click the Exit button

24

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Chapter 5: Configuring the IDR-C


Setting the Transmission/Reception Channel
Before
making the
setting

Before setting the transmission/reception channel, open the System


tabbed sheet, click Home Config and check if the Channel Step value
is half the Channel Size value.

If so, select the RF Channels Numbers as follows: 1, 3, 5, 7 etc. or


2, 4, 6, 8 etc. depending on the desired transmission frequency to
avoid the existence of common frequencies between two different
RF Channels Numbers!
Procedure

To set the transmission/reception channel, follow the steps below:


Step
1
2

Action
Open the ODU tabbed sheet.
Select between the following, the ODU whose
transmission/reception channel you want to set:
LOCAL ODU A
LOCAL ODU B
REMOTE ODU A
REMOTE ODU B
In the Radio Frequency group box, click EDIT.

Continued on next page

25

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Setting the Transmission/Reception Channel, Continued


Procedure (continued)

Step
4

Action
From the RF Channel number drop-down list, select the
number of the RF transmission and reception channel.
Notice the values of the Tx Frq. and Rx Frq. boxes change
accordingly.
Note: The total number of the drop-down list RF channels
depends on the specific ODU channel bandwidth and the
number of E1 tributaries the ODU should serve.
Click COPY to apply the setting. Notice how the colours of
the RF Channel number drop-down list and the Tx Frq. and
Rx Frq. boxes change.

Setting the transmitted Power


Procedure

To set the transmitted power, follow the steps below:


Step
1
2

4
5

26

Action
Open the ODU tabbed sheet.
Select between the following, the ODU whose transmitted
power you want to set:
LOCAL ODU A
LOCAL ODU B
REMOTE ODU A
REMOTE ODU B
In the Radio Transmitter Power group-box, click EDIT.

From the TX PWR (dbm) drop-down list, select the


transmitted power.
Click COPY to apply the setting.

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Setting the RSSI Alarm Threshold


Info

If the reception level falls below the RSSI alarm threshold you set, an
alarm will be generated.

Procedure

To set the RSSI alarm threshold, follow the steps below:


Step
1
2

3
4

Action
Open the ODU tabbed sheet.
Select between the following, the ODU whose RSSI alarm
threshold you want to set:
LOCAL ODU A
LOCAL ODU B
REMOTE ODU A
REMOTE ODU B
In the Radio Thresholds group-box, click EDIT.

From the RSSI Thres. (dBm) drop-down list, select the


threshold.
Click COPY to apply the setting.

Note: In the Threshold Alarms group-box, the RSSI threshold alarm


indication turns ON if the reception level falls below the RSSI alarm
threshold you set.

27

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Setting the ODU Temperature Alarm Threshold


Info

The internal temperature of the ODU is approximately 25 C to 30 C


higher than the environmental temperature. The ODU can work
properly at an environmental temperature range 45 C to +90 C. The
application permits you to set an upper temperature threshold. If the
internal temperature of the ODU exceeds this threshold, an alarm will
be generated.

Procedure

To set the ODU temperature alarm threshold, follow the steps below:
Step
1
2

4
5

Action
Open the ODU tabbed sheet.
Select between the following, the ODU whose temperature
alarm threshold you want to set:
LOCAL ODU A
LOCAL ODU B
REMOTE ODU A
REMOTE ODU B
In the Radio Thresholds group-box, click EDIT.

From the Upper Temp. Thres. (C) drop-down list, select


the threshold.
Click COPY to apply the setting.

Note: In the Threshold Alarms group-box, the Temperature


threshold alarm becomes red if the internal temperature of the ODU
exceeds the alarm threshold you set.

28

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Enabling the ATPC Feature


Info

When you enable the ATPC (Automatic Transmission Power Control)


feature, you make the transmitter at the local station adjust its output
power so that the receiver at the remote station constantly receives the
desired level you have set.

Procedure

To enable the ATPC feature, follow the steps below:


Step
1
2
3

Action
Open the System tabbed sheet.
Click Home Config or Remote Config.
From the ATPC (dBm) drop-down list, select the desired
reception level (dBm) of the remote station.

Click Enable ATPC to enable the ATPC feature. Notice the


led turns ON.

29

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Deactivating the LOS Alarm for the unconnected Tributaries


Why to
deactivate the
LOS alarm for
the
unconnected
tributaries

Deactivate the LOS alarm for the unconnected (not cabled) tributaries
for the ALM led, on the front panel of the IDU MUX Unit, to indicate
real LOS when it occurs.

Note: The manufacturer provides the IDR-C with the LOS alarm
activated for all the tributaries.
Procedure

To deactivate the LOS alarm for an unconnected tributary, follow the


steps below:
Step
1
2

Action
Open the Tributaries tabbed sheet.
Select between the following the quadrate of tributaries:
Ho 1-4
Re 1-4
Ho 5-8
Re 5-8
Ho 9-12
Re 9-12
Ho 13-16
Re 13-16

Click LOS to deactivate the LOS alarm for the specific


tributary. After a while, the LOS Alarm Deactivated led
turns on.

30

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Setting the Link Identification Number


Info

The link identification number is a number in the range 0 to 15 the


operator selects through the LCT to identify in a unique way a link
between a local and a remote IDR-C. The link identification number is
extremely useful in cases of multiple links existing between two
stations as it prevents the stations from demodulating data belonging
to some other link if, by mistake, the stations lock into the frequency of
this link.

Procedure

To set the link identification number, follow the steps below:


Step
1
2

5
6

Action
Open the Modem tabbed sheet.
Select between the following, the remote IDR-C modem
whose link id you want to set:
REMOTE A
REMOTE B
In the Link Id Configuration group-box, from the drop-down
list select the link id you want in the range 0 to 15 and click
Send Link Id. The link id you selected appears in the
Framer Link Id box.

Select between the following, the local IDR-C modem whose


link id you want to set:
LOCAL A
LOCAL B
Repeat step 3 to set the same id.
Click Enable so that, in case the link id of the remote IDR-C
is other than the link id of the local IDR-C, an AIS alarm is
enabled at the tributaries outputs. The led beside the
Enable button becomes yellow.

31

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Changing the Ethernet Communication


Procedure

Note: The Ethernet interface is by default configured (AUTO option


button) to negotiate with the corresponding port of the remote device
concerning the rate (10 Mbit/s or 100 Mbit/s) and mode (half or full
duplex) of communication.
To change the default configuration of the Ethernet communication
(i.e. the auto-negotiation, follow the steps below.
Step
1
2

32

Action
Open the Ethernet tabbed sheet.
In the Ethernet Configuration Settings group-box, select
the appropriate option button depending on the rate and
mode of communication you want to achieve.

Click Send Configuration to apply the setting.

IDR-C_LCT_UserManual_04

IDR-C LCT User Manual

Changing the IDR-C Capacity


The manufacturer configures and provides the IDR-C with capacity
from 2 x E1 to 16 x E1 depending on the customers request.
If you want to change the system capacity, refer to Annex E: Changing
the IDR-C Capacity and Modulation (for the advanced User only) on
page 112.

Changing the IDR-C Modulation


The manufacturer configures and provides the IDR-C with QPSK or
16QAM modulation depending on the customers request.
If you want to change the system modulation, refer to Annex E:
Changing the IDR-C Capacity and Modulation (for the advanced User
only) on page 112.

33

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Chapter 6: Monitoring the IDR-C


Monitoring the IDR-C Configuration
To monitor the IDR-C configuration, open the System tabbed sheet
and then click Home Config or Remote Config if you want to monitor
the local or the remote IDR-C configuration, respectively.

Group box

Parameter
System Type

General

System Capacity
Modulation
Call Id
Station Name
Link Name
IP Address
ATPC

Description
HOT STBY: the ODU A and B
use the same RF Channel
Number to transmit and
receive providing radio
redundancy.
F.DIVERSITY: the ODU A and
B use different RF Channel
Numbers to transmit and
receive providing radio
redundancy.
UNPROTECTED: 1+0
topology
The number of tributaries the
System serves.
The modulation/demodulation
scheme of baseband signals.
Can be QAM or QPSK.
The station phone number for a
service call
The name of the station
The name of the link
The IP Address of the station
Drop-down list to select the
ATPC reception level (dBm) of
the remote station.
Continued on next page

34

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Monitoring the IDR-C Configuration, Continued


Group box

Parameter
Radio Type

Radio Band
Radio Tx
Radio A or
B

Radio Rx
Start Frq
Stop Frq
Output Power
Range Allowed
Channel Size
Channel Step

Description
xxC is the standard IDR-C
xxCHP is the High Power
IDR-C
where xx is the transmission
frequency (GHz) of the IDR-C
Note: This parameter is fully
related to the Output Power
Range Allowed (see further
down in this table).
The transmission band (High or
Low) of the ODU A or B
The frequency (MHz) in which
the ODU is transmitting at this
moment.
The frequency (MHz) in which
the ODU is receiving at this
moment.
The start frequency (MHz) of the
ODU A or B transmission band
The stop frequency (MHz) of the
ODU A or B transmission band
The allowed range of the ODU A
or B output power (dBm)
The RF channel bandwidth (kHz)
How many kHz exist between
two successive RF channel
numbers.

35

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Monitoring the Radio Measurements and Other ODU


Information
Radio
measurements

To monitor the radio measurements, follow the steps below:


Step
1
2

Action
Open the ODU tabbed sheet.
Select between the following the ODU whose radio
measurements you want to view:
LOCAL ODU A
LOCAL ODU B
REMOTE ODU A
REMOTE ODU B

Measurement
Pif
Rx In
Pout
Temperature
+12 V, +6,5 V, +5 V, -12 V

Description
The power (dBm) of the Tx
IF signal
The ODU reception level
(dBm)
The power (dBm) at the
ODU output i.e. the
transmission power
The temperature inside
the ODU
The output voltages of the
corresponding ODU
internal power supply units
Continued on next page

36

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Monitoring the Radio Measurements and Other ODU


Information, Continued
Other ODU
information

Information
ODU S/N
ODU Id
fctx
fcrx
bw
bm

Spectrum Inversion

Description
The serial number of the ODU
The identification number of the ODU
The central frequency (MHz) of the
duplexer transmission filter
The central frequency (MHz) of the
duplexer reception filter
The duplexer bandwidth (MHz)
The duplexer bandwidth margin (MHz)
which is the margin between the
duplexer bandwidth start frequency and
the duplexer first fc.
For manufacturer use only

37

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Monitoring the IDR-C Version


Info

The application gives you the ability to monitor a great amount of


information concerning the version of the LCT application, the firmware
version of the ODU, the versions of the mux, CMS, framer pcbs etc.

Procedure

To monitor the IDR-C version, open the Versions tabbed sheet.

Group-box
LCT.Exe Version

Field
LCT Version

ODU Versions

ODU A
ODU B
PCB

MUX Versions

FPGA

Description
The version of the
LCT application file
The firmware version
of the ODU
Version of the Mux
pcb
Version of the Mux
FPGA
Continued on next page

38

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Monitoring the IDR-C Version, Continued


Group-box
CMS Version

Field
BIN
PCB
FPGA

FRAMER A or B
Versions

CMS Type
System.ini
FPGA
FPGA Mod./BitRate
PCB
TxIF

Description
Version of the CMS
bin file
Version of the CMS
pcb
Version of the CMS
FPGA
Type of the CMS
System.ini file
Version of the
Framer/Modem
FPGA
The code type of the
Framer/Modem
FPGA
Version of the
Framer/Modem pcb
The Tx IF frequency

39

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Optimizing the Link


Info

To achieve reliable transmission in a microwave link, the transmitted


power plus the gain of the transmitter and receiver antennas should
exceed the attenuation at the transmission path and the sensitivity of
the receiver. The attenuation at the transmission path is given in the
following formula:
A=92.4+20logD+20logF
A is the attenuation at the transmission path in dB
D is the distance between the antennas in km
F is the frequency of the microwave signal in GHz

Prerequisites

If you use the LCT to observe the reception level or the RSSI, you will
need another person to move the antenna.

Procedure

To optimize the link, while performing minor horizontal and vertical


movements of the antenna, do one of the following:
Open the ODU tabbed sheet and check the reception level in the Rx
In box in the Radio Measurements group box:

Open the IDR View tabbed sheet and check the reception level in
the Rx In box in the appropriate ODU Home group box:

40

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Monitoring the Ethernet Link


To monitor the Ethernet link, follow the steps below:
Step
1
2

Action
Open the Ethernet tabbed sheet.
In the Ethernet Interface group-box, you monitor the
Ethernet link state. If the led Link is on, the Ethernet link is
up.

Parameter
Speed
Duplex
AUTO

Description
The current speed of the link. Can be
10 Mbps or 100 Mbps.
The current communication mode.
Can be HALF or FULL.
Shows if the auto-negotiation between
the IDR-C Ethernet interface and the
corresponding port of the remote end
is enabled (YES) or not (NO).

41

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Chapter 7: Monitoring the IDR-C Alarms


Monitoring
the IDR-C
alarms

To monitor the IDR-C alarms at the local or the remote station, follow
the steps below:
Step
1

Action
Open the IDR View tabbed sheet.

Item
1Q, 2Q, 3Q, 4Q
Tloops
PS A, B
EOW
MUX
User I/O
Mod. A, B
IDU
ODU A, B

Description
Quadrate of tributaries
Not used
Power Supply Units (lower and
upper)
Engineering Order Wire
Multiplexer
User Inputs/Outputs
Framer/Modem/Cable Interface Unit
(lower and upper)
Indoor Unit
Outdoor Unit
Continued on next page

42

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Monitoring the IDR-C Alarms, Continued

Step
2

Action
Check if any of the blocks (units, paths, cable or RF links)
appears red. If so, open the corresponding tabbed sheet to
view the alarms detected. In the example below, you should
open the Local and Remote Modem A and ODU A tabbed
sheets. Find in the next paragraphs a full description of the
alarms appearing in the different tabbed sheets.

Note 1: If the User I/O block appears red, open the System
tabbed sheet and click Home or Remote I/O Status to view
the alarms detected.
Note 2: If the EOW block appears red, contact the
manufacturer as the corresponding card should be replaced.
Note 3: The red exclamation mark indicates the LCT cannot
communicate with the corresponding ODU.

Note 4: The value in the Rx In box is the ODU reception


level (dBm). The value in the PA Out box is the output
power (dBm) of the transmitter. The red backround instead
of the green one denotes alarm. For more details, see page
44.

43

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

ODU Alarms
To monitor the ODU alarms, open the ODU tabbed sheet.
General
Alarms

Alarm
Rx In

Generated when:
The reception level falls below a threshold the
manufacturer has set for a reliable RF link
performance. This threshold depends on the bit
rate and the modulation type according to the
following table:
Modulation
QPSK/SQPSK
16QAM
QPSK/SQPSK
16QAM
QPSK/SQPSK
16QAM
QPSK/SQPSK
128QAM

Bit Rate
(Mbit/s)
2x2
4x2
4x2
8x2
8x2
16 x 2/E3
16 x 2/E3
STM1

Threshold
(dBm)
-79
-80
-76
-77
-73
-74
-73
-64

The Rx In threshold alarm also appears in the IDR


View tabbed sheet as follows. The value in the
box is the current Rx In level (dBm) of the ODU.

PA Out

There is no RF signal at the output of the ODU


Power Amplifier and consequently at the output of
the ODU.
Continued on next page

44

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

ODU Alarms, Continued


Threshold
Alarms

Alarm
RSSI
Temperature
Pif
+5 V
+6,5 V
+12 V
-12 V

Generated when:
The reception level falls below the RSSI threshold
you have set (refer to page 27).
The temperature inside the ODU exceeds the
threshold you have set (see page 28).
The power of the Tx IF signal falls below
20 dBm.
The output voltage of the ODU internal power
supply unit falls below +4,5 V.
The output voltage of the ODU internal power
supply unit falls below +6 V.
The output voltage of the ODU internal power
supply unit falls below +11 V.
The output voltage of the ODU internal power
supply unit falls below 11 V.
Continued on next page

45

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

ODU Alarms, Continued


Radio Locks
Alarms

Alarm
LD DDS
(Lock Detect
Digit Direct
Synthesizer)
LD Lback
(Lock Detect
Loopback)

LD MW
LD RX
(Lock Detect
Rx)
LD TX
(Lock Detect
Tx)

46

Generated when:
The Digit Direct Synthesizer is unlocked with
consequence no RF signal at the Power Amplifier
output and the generation of the PA Out alarm.
Contact the manufacturer for ODU replacement.
The Loop Back Synthesizer is unlocked. This
alarm can be generated during the RF loopback
test (ODU LOOP command button of the LOCAL
ODU tabbed sheet). The ODU LOOP command
activates the Loop Back Synthesizer which loops
the Tx signal in the Rx path.

Not used
The Rx Synthesizer is unlocked.
The Tx Synthesizer is unlocked with consequence
no RF signal at the Power Amplifier output and the
generation of the PA Out alarm as well. Contact
the manufacturer for ODU replacement.

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Framer/Modem/CI Alarms
FRAMER/
MODEM/CI
Alarms

To monitor the Framer/Modem/CI Unit alarms, open the Modem


tabbed sheet.

Alarm

Generated when:

Tx PLL

The Tx Synthesizer of the Framer/Modem/Cable


Interface Unit is unlocked. Check the
Framer/Modem/Cable Interface Unit of the other
path and if the problem persists, contact the
manufacturer for card replacement.

Rx PLL

The Rx Synthesizer of the Framer/Modem/Cable


Interface Unit is unlocked.

BER3

BER 10-3

BER6

BER 10-6

Dmod
(Demodulator
Alarm)
LFA
(Lost Frame
Alignment
Alarm)

The Modem cannot demodulate the carrier


information.
The alignment of the frame has been lost.

TxIF

A hardware error has occurred in the card.


Contact the manufacturer for card replacement.

LnkId
(Link
Identification
Alarm)

The Framer/Modem/Cable Interface Unit cannot


recognize the Identification Number of the link.

47

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Mux Alarms
To monitor the Mux alarms, open the Mux tabbed sheet.

Alarm
LOS CLK A
Path
(Loss of Signal
Clock A Path)
LOS CLK B
Path
(Loss of Signal
Clock B Path)

48

Generated when:
The clock coming from the Framer/Modem/CI Unit
A has been lost. Consequently, the hitless
switching cannot be performed.
The clock coming from the Framer/Modem/CI Unit
B has been lost. Consequently, the hitless
switching cannot be performed.

FIFO A

A hardware error has occurred in the A path in the


card. Contact the manufacturer for card
replacement.

FIFO B

A hardware error has occurred in the B path in the


card. Contact the manufacturer for card
replacement.

LOS Align
(Loss of Signal
Align)

The synchronization between the signals coming


from the demodulators A and B has been lost.
Consequently, the hitless switching cannot
operate properly.

SYNC
(Synchronization)

The frame coming from the Framer/Modem/CI


Unit has been lost or has BER 10-6.

RAI
(Remote Alarm
Indication)

The remote station cannot receive the signal


transmitted or receives it with BER 10-6. As a
consequence, the remote station sends the RAI
alarm to the local station.

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Power Supply Alarms


To monitor the Power Supply alarms, open the Power Supply tabbed
sheet.

Alarm
Power Supply
Alarm

Generated when:
There is no input voltage at the Power Supply
Unit.

Card Extracted Card extracted

49

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Tributaries/Service Channels Alarms


To monitor the Tributaries or the Service Channels alarms, open the
Tributaries tabbed sheet.

Alarm

IN AIS

LOS
(Loss of Signal)

Generated when:
The AIS pattern (all ones sequence) is applied at
the specific tributary input.
Note: When no AIS is applied at the input, the
optical indication is green.
There is no signal at the specific tributary input.

Note: To monitor the service channels alarms, click the Service


Channels tab in the Tributaries tabbed sheet.

Ethernet Alarms
To monitor the Ethernet alarms, open the Ethernet tabbed sheet.

Alarm
SYNC
(Synchronization)
RAI
(Remote Alarm
Indication)

50

Generated when:
The MUX in the local station is not locked in the
incoming MUX frame.
The MUX in the remote station is not locked in the
incoming MUX frame.

IDR-C_LCT_UserManual_04

IDR-C LCT User Manual

User Alarms Inputs/Outputs


The AUX connector on the front panel of the IDU CMS provides four
user alarms inputs and four user alarms outputs.
In the inside of the system, as soon as an alarm input/output appears
at the pin of the connector, a micro-switch connects or disconnects the
pin of this alarm input/output and the input/output GND.
To monitor the indications of the user alarms inputs and outputs, open
the System tabbed sheet and then click Home I/O Status or Remote
I/O Status depending on which you want to monitor. If you want to
change the alarms names (UserInput_1 etc. ) with other more
convenient names (e.g. Station Door Open), see par. Changing the
Alarms Attributes on page 55.

51

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Monitoring the History of Alarms


Info

The application gives you the ability to monitor the history of alarms
that were generated in the system. More specifically, you can select to
monitor the last 20 or 50 alarms or you can select to monitor all the
alarms (up to 999). When you select to monitor the alarms, the system
creates a text type alarm log file with the name Log_<date>. When you
close the management application, the system saves this alarm log file
in the LCT in the same folder with the management application.
Note: Do not delete the alarm log file as the manufacturer may
request it in case of troubleshooting.
The manufacturer provides the system with a list of alarms with default
name, severity and polarity. He has also set which alarms will appear
at the users outputs and which alarms will be logged. Although the
application gives you the ability to change these attributes, you are
recommended to wait until you become an experienced operator of the
system.

Monitoring
the history of
alarms

To monitor the history of alarms, follow the steps below:

Step
1

Action
On the System menu, point to Alarm Log, then point to
Activation, and then select one of the following:
Last 20 if you want to monitor the last 20 alarms
Last 50 if you want to monitor the last 50 alarms
All if you want to monitor all the alarms (the application
can log up to 999 alarms)
Continued on next page

52

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Monitoring the History of Alarms, Continued

Step
2

Action

Attribute
Count

Time
State

Description
Alarm counting number
The most recent alarm appears at
the end of the list. Up to 999 alarms
can appear in the list. On receipt of
the 1000th alarm, the oldest alarm is
automatically deleted and the new
alarm appears at the end of the list.
Time and day (according to
the IDR-C clock) the alarm was
generated.
ON: the alarm is enabled.
OFF: the alarm is disabled.
Continued on next page

53

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Monitoring the History of Alarms, Continued

Step
Severity

Polarity

Output
Name

54

Action
The alarm severity
Minor
Major
Normal is the Normal Open
(default). With this setting, as
soon as an alarm appears at the
input/output pin of the AUX
connector, the micro-switch in the
internal of the system connects
this alarm input/output pin to the
alarm input/output GND of the
connector.
Reverse is the Normal Close. As
soon as an alarm appears at the
input/output pin of the AUX
connector, the micro-switch in the
internal of the system disconnects
this alarm input/output pin from
the alarm input/output GND of the
connector.
The alarm input/output at the AUX
connector
The alarm name

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Changing the Alarms Attributes


Info

The alarms attributes are recorded in the alrm.nme and alrm.attr files
stored in the CMS Unit. If you want to change the alarm attributes, you
should upload these files from the CMS Unit, make the changes you
want, delete the old files from the CMS Unit and then download the
new files to the CMS Unit.
Note: Although the application gives you the ability to change the
alarms attributes, you are recommended not to do this unless you are
an experienced user.

Default
alarms
attributes

See Annex D.

Changing the
alarms
attributes

To change the alarms attributes, follow the steps below:

Step
1

Action
Create two folders. You will use the one folder to store the
current alrm.nme and alrm.attr files of the CMS unit and the
other folder to store the new alrm.nme and alrm.attr files you
will create.
On the System menu, select FTP Tool. The following
window appears:

Continued on next page

55

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Changing the Alarms Attributes, Continued

Step
3

4
5
6
7

Action
In the Host box, type the address of the IDR-C from which
you want to upload the alrm.nme and alrm.attr files and click
FTP Connection. In the Files list (NMU) list, the current
files of the CMS Unit appear.
From the Files list (Local) list, select the folder where you
want to move the alrm.nme and alrm.attr files.
From the Files list (NMU) list, select the alrm.nme file and
click Upload from NMU.
Browse the folder to which you want to move the file and
click Save.
In the window that appears, click OK to confirm the
uploading.

8
9
10

Repeat steps 5, 6 and 7 for the alrm.attr file.


Click Close FTP.
On the System menu, point to Alarm Log, and then select
Alarm Tool.

11

On the File menu of the Alarm Tool window, select Open to


open the alrm.nme and alrm.attr files.
Open the appropriate tabbed sheet. The current attributes
appear.
In the Alarm Name box, type the new name of the alarm.

12
13

Continued on next page

56

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Changing the Alarms Attributes, Continued

Step
14
15

16
17
18
19
20

21

Action
From the Severity drop-down list, select the severity of the
alarm between Minor and Major.
From the Polarity drop-down list, select the polarity of the
alarm at the user output between Normal and Reverse
taking into consideration the following Note:
Note: You are recommended not to change the polarity
unless this alarm appears at the user output and you want to
change the default status of the alarm (Normal Open which
is the default or Normal Close).
Select the Output check box if you want the alarm to appear
at the user output.
Select the Logged check box if you want the alarm to be
stored in the alarm log file and thus appear in the alarms
history list.
Repeat for as many alarms as needed.
Click OK.
On the File menu of the Alarm Tool window, select Save.
The following window appears:

Select the folder you have created in step 1 for the new files.
Continued on next page

57

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Changing the Alarms Attributes, Continued

Step
22

Action
In the File name box, type alrm.nme and click Save. The
following window appears:

23
24
25

In the File name box, type alrm.attr and click Save.


On the File menu of the Alarm Tool window, select Exit.
On the System menu, select FTP Tool. The following
window appears:

26

In the Host box, type the address of the IDR-C to which you
want to download the new alrm.nme and alrm.attr files and
click FTP Connection.
From the File list (NMU) list, select the alrm.nme and
alrm.attr files and click Delete from NMU to delete them.

27

Continued on next page

58

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Changing the Alarms Attributes, Continued

Step
28
29
30

Action
From the Files list (Local) list, select the alrm.nme and
alrm.attr files you created and click Download to NMU.
Click Close FTP.
On the System menu, select Sys Restart to activate the
new files or press the RST button on the front panel of the
IDU CMS Unit.

59

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Chapter 8: Service Calls


Changing the Station Call Id for a Service Call
Procedure

To change the Station Call Id number, follow the steps below:


Step
1

Action
On the System menu click Call ID Change. The following
window appears:

From the New Call Id drop-down list in the Home Terminal


Call Id group-box or/and in the Remote Terminal Call Id
group-box, select the new Call Id of the local station or/and
the remote station respectively. The available range is 0 to
99.

In the group-box(es) you changed the Call Id, click Apply to


apply the new Call Id.

On the System menu, point to Configuration, Home or


Remote and select Save to save the new Call Id.

Click Close to close the window.

Note: You do not need to reset the IDR-C for the change to apply.

60

IDR-C_LCT_UserManual_04

IDR-C LCT User Manual

Performing a Service Call


Prerequisites

To perform a service call to the remote station, you should know its
Call Id number. If you do not know the number, open the System
tabbed sheet, click Remote Config and view the value of the Call
Id in the General group-box.
For the local and remote stations to be able to communicate through
a service call, you should have connected the handsets to the local
and remote stations IDUs.

Performing a
selective
service call

To perform a service call to the remote station, hook-off the handset,


press #, dial the Call Id number of the remote station and then press *.

Performing a
general
service call

To perform a service call to all the stations of the NMS network, press
#, then press 0 and then press *.

61

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Chapter 9: Loopbacks, Performance Monitoring & Other


Tests
Changing the Transmission and/or Reception Path
When to
change the
default
selection

Change the default selection (auto) if you want to set free of traffic a
path for service purposes (e.g. you will select to transmit and receive
through the A path if you want to perform measurements on the B
path). In this case, the hitless switching and thus the radio redundancy
will not operate.

Procedure

To change the transmission and/or reception path, follow the steps


below:
Step
1

Action
Open the IDR View tabbed sheet.

Click the appropriate option button to select the transmission


and/or the reception path.
Continued on next page

62

IDR-C_LCT_UserManual_04

IDR-C LCT User Manual

Changing the Transmission and/or Reception Path, Continued


Note 1: With the default selection (auto option button clicked), you
allow the system to select the transmission and/or reception path. The
system makes the selection according to the voltages Pif, Rx In and
Pout levels of the Radio Measurements group box and according to
the detection or not of the following alarms:
Alarms for the transmission path
PA OUT
LD DDS
LD TX
RAI
Alarms for the reception path
RSSI
LD DDS
LD Rx
BER3
BER6
Note 2: You can select the transmission and/or reception path by
opening the MUX tabbed sheet as well.

63

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Loopbacks
Info

The application gives you the ability to perform the following


loopbacks:

LLOOP: Line Loop (Local and Remote Station)


DLOOP: Digital Loop (Local Station)
ODU LOOP (Local Station)
RLOOP: Radio Loop (Local and Remote Station)

The following figure represents the above mentioned loopbacks


graphically:
LLOOP

RLOOP

Local
Mux

Loopbacks
order

DLOOP

Local
Framer/
Modem/
CI

Local
ODU

RF Link

ODU LOOP

Remote
ODU

DLOOP

Remote
Framer/
Modem/
CI

RLOOP

LLOOP

Remote
Mux

You are recommended to perform the loopbacks in the following order:


Step
1
2
3
4

Performing
the LLOOP

ODU LOOP

Action
LLOOP
DLOOP
ODU LOOP
RLOOP

To perform the LLOOP, follow the steps below:


Step
1
2

Action
Open the Tributaries tabbed sheet.
Click LLOOP in the Tributaries Control group-box of the
tributary you want to test:

Continued on next page

64

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Loopbacks, Continued
Performing
the DLOOP

To perform the DLOOP, follow the steps below:


Step
1
2

Performing
the ODU
LOOP

Action
Open the Modem tabbed sheet.
Click DLOOP in the Control group-box of the
Framer/Modem/CI Unit you want to test:

To perform the ODU LOOP, follow the steps below taking into
consideration the following important Note:
Important Note: Switch-off the remote station and then proceed to
the ODU LOOP!
Step
1
2

Action
Open the ODU tabbed sheet.
In 1+1 topology, in the Radio Control group-box, click ODU
MUTE to mute the ODU you dont want to test (e.g. if the
ODU A seems to have problems and you want to test it,
mute the ODU B).
Continued on next page

65

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Loopbacks, Continued
Performing the ODU LOOP (continued)

Step
3

Performing
the RLOOP

Click ODU LOOP in the Radio Control group-box of the


ODU you want to test:

To perform the RLOOP, follow the steps below:


Step
1
2

66

Action
Open the MUX tabbed sheet and change the transmission
and reception path accordingly (e.g. continuing the example
of step 2, click the A options buttons in the TxSW and
RxSW group-boxes).

Action
Open the Tributaries tabbed sheet.
Click RLOOP in the Tributaries Control group-box of the
tributary you want to test:

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Monitoring the Performance of the RF Link


Info

You can monitor the performance of the RF link by performing the


G.826 block error analysis test (ITU-T Recommendation G.826: Endto-end error performance parameters and objectives for international,
constant bit-rate digital paths and connections).

Performing
the G.826 test

To perform the G.826 test, follow the steps below:


Step
1
2

Action
Open the System tabbed sheet.
Click Home G826. The following window appears:

Continued on next page

67

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Monitoring the Performance of the RF Link, Continued


Performing the G.826 test (continued)

Step
3

Action
If the Test Running led is on, click STOP TEST and then
click START TEST otherwise click START TEST. Wait a few
milliseconds for the internal error counters to reset. Then the
test starts. Find below the description of the error
performance parameters (according to G.826):
Parameter
ES
SES

BBE
Unavailable Time

Available Time
Total Time

68

Description
Errored Second, a one-second
period with one or more errored
or lost blocks
Severely Errored Second, a
one-second period which
contains 30 % errored blocks
or at least one defect; onesecond period which has a bit
error ratio
10-3 or during which Loss of
Signal or Alarm Indication
Signal is detected; SES is a
subset of ES.
Background Block Error, an
errored block not occurring as
part of a SES.
The Unavailable Time (s) starts
when 10 consecutive severely
errored seconds have been
detected. These 10 seconds
are part of the Unavailable
Time. If a bidirectional path is
considered, the Unavailable
Time is if one or both directions
are unavailable.
The Available Time (s) starts
after 10 consecutive non-SES
seconds have passed.
Unavailable Time + Available
Time

IDR-C_LCT_UserManual_04

IDR-C LCT User Manual

Enabling the AIS Transmission at the Tributaries Outputs


Open the Mux tabbed sheet and then click Toggle AIS to enable
(default) / disable the AIS transmission at the tributaries outputs in
case of RF link failure so that if there are systems connected to the
IDR-C, they will continue to be synchronized with it. The led turns on if
you have enabled the AIS transmission.

Imposing SinCos Demodulation


Open the Modem tabbed sheet and then click SinCos to interrupt the
QAM or QPSK demodulation and impose the SinCos demodulation.
Then you will be able to check the central transmission frequency fc
during laboratory testing.

69

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Chapter 10: Upgrading the IDR-C Firmware


Prerequisite

The manufacturer provides you an xxx.bin file with the new IDR-C
firmware.

Procedure

To upgrade the IDR-C firmware, follow the steps below:


Step
1
2
3

4
5
6
7

Action
Launch the LCT application.
Get connected to the IDR-C.
On the System menu, select FTP Tool. The following
window appears:

In the Host box type the IP address of the IDR-C you want
to change the firmware and click FTP Connection to get
connected.
In the Files list (Local) select the IDR-C firmware upgrading
file (xxx.bin) and click Download to NMU.
After the downloading procedure has been completed, in the
Files list (NMU) select the config.sys and the boot.sys files
and click Upload from NMU.
In the Files list (Local) select the folder in which you want
to save the two files. Pay attention not to select the folder
where the config.sys and boot.sys files of Windows are
saved because if you do so, the Windows files will be
overwritten by the NMU files.
Use a text editor to open the two files and change the name
of the xxx.bin file with the new one.
Continued on next page

70

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Upgrading the IDR-C Firmware, Continued


Procedure (continued)

Step
9
10
11
12

Action
Save the files.
From the Files list (NMU) list, delete the current config.sys
and boot.sys files.
From the Files list (Local) list, select the new config.sys file
and click Download to NMU. Do the same for the new
boot.sys file.
To activate the new files, do one of the following to reset the
IDR-C:
On the System menu, select Sys Restart.
Press the RST button on the front panel of the IDU CMS
Unit.
Switch-off and on again the IDR-C PSU(s).

71

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Annex A: Installing the Manufacturer Driver at the LCT and


creating a dial-up Connection to the IDR-C (Manual
Procedure)
Why to install
the
manufacturer
driver

You need to install the manufacturer driver at your LCT because


during the installation a virtual modem is created making possible the
exchange of IP packets (needed by the LCT management application
which is IP based) through the RS-232 ports of the LCT and the IDRC.

When to
perform the
procedure

You need to install the manufacturer driver at your LCT and create a
dial-up connection to the IDR-C of the station before launching the
IDR-C management application (IDR-C MASTER) and getting
connected to the IDR-C.

72

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Manufacturer Driver (Win 2000, XP)


Accessory

CD with the manufacturer driver (provided)

Procedure

To install the manufacturer driver at your LCT, follow the steps below:
Step
1

Action
Select Start > Settings > Control Panel > Phone and
Modem Options. The following window appears:

Continued on next page

73

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Manufacturer Driver (Win 2000, XP), Continued

Step
2

Action
Open the Modems tabbed sheet. The following window
appears:

Continued on next page

74

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Manufacturer Driver (Win 2000, XP), Continued

Step
3

Action
Click Add. The following window appears:

Select the Dont detect my modem; I will select it from a


list check box and click Next. The following window
appears:

Continued on next page

75

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Manufacturer Driver (Win 2000, XP), Continued

Step
5

Action
Click Have Disk.The following window appears:

From the drop-down list select the CD disk drive, click


Browse, select the nmudirwin2000.inf file (if you have
Windows 2000) or the directxp.inf file (if you have Windows
XP), click Open and then OK. The following window
appears:

Continued on next page

76

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Manufacturer Driver (Win 2000, XP), Continued

Step
7

Action
Select the model and click Next. The following window
appears:

Continued on next page

77

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Manufacturer Driver (Win 2000, XP), Continued

Step
8

Action
Select an available communication port (e.g. COM1) and
click Next. The following window appears:

Windows 2000

Windows XP
9

Click Yes (if you have Windows 2000) or click Continue


Anyway (if you have Windows XP) to continue the
installation.
Continued on next page

78

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Manufacturer Driver (Win 2000, XP), Continued

Step
10

Action
When the installation is completed, the following window
appears:

Continued on next page

79

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Installing the Manufacturer Driver (Win 2000, XP), Continued

Step
11

12

80

Action
Click Finish. The following window appears:

Click OK.

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C


Creating a dial-up Connection to the IDR-C (Win 2000)
Prerequisite

Before proceeding to the creation of the dial-up connection, you


should first have installed the driver provided by the manufacturer at
your LCT.

Procedure

To create a dial-up connection between the LCT and the IDR-C, follow
the steps below:
Step
1

Action
Select Start > Settings > Control Panel > Network and
Dial-up Connections > Make New Connection. The
following window appears:

Continued on next page

81

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win 2000),


Continued

Step
2

Action
Click Next. The following window appears:

Click the Connect directly to another computer option


button and then click Next. The following window appears:

Continued on next page

82

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win 2000),


Continued

Step
4

Action
Click the Guest option button and then click Next. The
following window appears:

Select the virtual modem you created during the installation


of the PPP driver and click Next. The following window
appears:

Continued on next page

83

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win 2000),


Continued

Step
6

Action
Click the For all users option button and click Next. The
following window appears:

Type the name you want to use for this connection (e.g.
CMS) and click Finish. The following window appears:

Continued on next page

84

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win 2000),


Continued

Step
8

Action
Leave the User name and Password boxes empty and click
Properties. The following window appears:

Continued on next page

85

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win 2000),


Continued

Step
9

Action
From the Select a device drop-down list, select the virtual
modem you created during the installation of the
manufacturer driver and click Configure. The following
window appears:

Continued on next page

86

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win 2000),


Continued

Step
10

Action
From the Maximum speed drop-down list select 57600.
Make sure that all the check boxes are not selected. Click
OK. The following window appears:

Continued on next page

87

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win 2000),


Continued

Step
11

12

Action
Open the Options tabbed sheet and select the Display
progress while connecting check box:

Click OK. The following window appears:

Continued on next page

88

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win 2000),


Continued

Step
13

14

Action
When the connection to the IDR-C is created, the following
window appears:

Double-click the icon of the connection in the status bar:

The following window appears:

Continued on next page

89

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win 2000),


Continued

Step
15

90

Action
Open the Details tabbed sheet to view details concerning
the connection:

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win XP)


Prerequisite

Before proceeding to the creation of the dial-up connection, you


should first have installed the driver provided by the manufacturer at
your LCT.

Procedure

To create a dial-up connection between the LCT and the IDR-C, follow
the steps below:
Step
1

Action
Select Start > Settings > Control Panel > Network
Connections. In the Network Tasks pane of the window
that appears click Create a new connection:

The following window appears:

Continued on next page

91

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win XP), Continued

Step
2

Action
Click Next. The following window appears:

Click the Set up an advanced connection option button


and then click Next. The following window appears:

Continued on next page

92

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win XP), Continued

Step
4

Action
Click the Connect directly to another computer option
button and then click Next. The following window appears:

Click the Guest option button and then click Next. The
following window appears:

Continued on next page

93

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win XP), Continued

Step
6

Action
In the Computer Name box, type the name you want to use
for this connection (e.g. CMS) and click Next. The following
window appears:

From the Select a device drop-down list, select the virtual


modem you created during the installation of the
manufacturer driver and click Next. The following window
appears:

Continued on next page

94

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win XP), Continued

Step
8

Action
Select the Add a shortcut to this connection to my
desktop check box if you want a shortcut and then click
Finish. The following window appears:

Continued on next page

95

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win XP), Continued

Step
9

Action
Leave the User name and Password boxes empty and click
Properties. The following window appears:

Continued on next page

96

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win XP), Continued

Step
10

Action
From the Select a device drop-down list, select the virtual
modem you created during the installation of the
manufacturer driver and click Configure. The following
window appears:

Continued on next page

97

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win XP), Continued

Step
11

Action
From the Maximum speed drop-down list select 57600.
Make sure that all the check boxes are not selected. Click
OK. The following window appears:

Continued on next page

98

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win XP), Continued

Step
12

13

Action
Open the Options tabbed sheet and select the Display
progress while connecting check box if not selected.
Leave the other check boxes unselected:

Click OK. The following window appears:

Continued on next page

99

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win XP), Continued

Step
14

15

Action
When the connection to the IDR-C is created, the following
window appears:

Double-click the icon of the connection in the status bar:

The following window appears:

Continued on next page

100

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Creating a dial-up Connection to the IDR-C (Win XP), Continued

Step
16

Action
Open the Details tabbed sheet to view details concerning
the connection:

101

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Annex B: Changing the Station Name, the Link Name and the
Station IP Address
IDR-C IP Addressing
Each station with an IDR-C system is assigned an IP address so that it
can be identified in a network. The IP address of each station has to
be unique in the network to which the station belongs. You can use the
LCT, type the appropriate IP addresses and get connected, monitor
and configure up to 10 stations. All stations should belong to the same
subnet with subnet mask 255.255.255.0
As four IP addresses should be reserved for each station (the IDR-C
station address, the broadcast address, the network address and the
LCT address assigned to the LCT through the creation of the dial-up
connection between the LCT and the IDR-C), the IP address of the
station should have the following format:
A.B.C.D/30 with D=4n+1 where n is an integer from 1 to 62.
See below an example of IP addressing:
Station
Station 1
Station 2
Station 3
Station 4

Station 10

102

IP Address
192.168.59.5
192.168.59.9
192.168.59.13
192.168.59.17

192.168.59.41

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Finding out the IP Address of your Station


Prerequisite

Before proceeding to the procedure, you should create a dial-up


connection between your LCT and the IDR-C.

Procedure

To find the IP address of your station, follow the steps below:


Step
1
2
3

Action
Double-click on the icon of the dial-up connection that you
created for the communication of your LCT with the IDR-C.
Select Start>Run.
In the Open box, type command (Windows 2000 or XP). In
the DOS prompt, type ipconfig.

You view the IP address of your LCT.


4

To find the IP address of the station, reduce the IP address


of your LCT by one.
In the example, the IP address of the station is
192.168.59.37

103

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Changing the Station Name, the Link Name and the IP


Address of your Station
Info

The name of the link and the name and IP address of the station are
stored in the config.sys file that is kept in the CMS card of each
station. The IP address of the station is also stored in the boot.sys file
of the system.
If you want to change the IP address of a station, you should change
the contents of the boot.sys and config.sys files accordingly. If you
want to change the link name and the station name, you should
change the contents of the config.sys file.

Prerequisite

Before proceeding to the procedure, you should create a dial-up


connection between your LCT and the IDR-C.

Procedure

To change the link name and the name and IP address of a station,
follow the steps below:
Step
1
2
3
4
5

Action
Upload the config.sys and boot.sys files from the IDR-C to
your LCT.
With a text editor open the files and change the name of the
link and the name and IP address of the station.
Delete the old config.sys and boot.sys files from the IDR-C.
Download the modified files from your LCT to the IDR-C.
Reset the IDR-C.

Find the detailed description of the preceding steps in the following


paragraphs.
Continued on next page

104

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Changing the Station Name, the Link Name and the IP


Address of your Station, Continued
Uploading
from IDR-C

To upload the config.sys and boot.sys files from the IDR-C to your
LCT, follow the steps below:
Step
1
2
3
4
5
6
7
8
9
10

Action
Create a folder in the disk of your LCT (e.g. idrc).
Double-click on the icon of the dial-up connection that you
created for the communication of the local terminal with the
IDR-C.
Select Start>Run and type command in the Open box.
At the DOS prompt, type FTP xxx where xxx is the current
IP address of the station, and then press ENTER.
Type the username and the password, and then press
ENTER. By default, the username is aris and the password
is akand.
Type lcd dirname where dirname is the name of the folder
you created (e.g. lcd c:\idrc), and then press ENTER.
Type get config.sys, and then press ENTER to upload the
config.sys file from the IDR-C to the folder of the LCT.
Type get boot.sys, and then press ENTER to upload the
boot.sys file from the IDR-C to the folder of the LCT.
Type bye, and then press ENTER to return to the DOS
prompt.
Type exit, and then press ENTER to return to Windows.
Continued on next page

105

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Changing the Station Name, the Link Name and the IP


Address of your Station, Continued
Editing the
config.sys
and boot.sys
files

To edit the config.sys and boot.sys files, follow the steps below:

Step
1

Action
With a text editor open the config.sys and boot.sys files. The
file format will be similar to the one below (depending of
course on the frequency and the type of the station):
The config.sys file
boot id180203.bin 0xa000400
MANAGER_IPADDRESS 146.124.12.75
MANAGER_PORT 16205
MY_IPADDRESS 192.168.50.31
SUBNET_MASK 255.255.255.252
lnkname
LowSyst The station name
sysname
Intracom The Link name
systype
1
1+1

The boot.sys file


boot id180203.bin 0xa000400
MANAGER_IPADDRESS 146.124.12.75
MANAGER_PORT 16205
MY_IPADDRESS 192.168.50.31
SUBNET_MASK 255.255.255.252

In both files, replace the IP address next to the


MY_IPADDRESS record with the new one.
Note: If you want, you can also change the name of the
station that appears on the display of the CMS and the
name of the link. To do so, in the sixth line of the config.sys
file, change the name of the station from the LowSyst of the
example to the one you want to appear on the display of the
CMS. In the seventh line of the config.sys file, change the
name of the link from Intracom of the example to the one
you want.
Save the config.sys and boot.sys files and close the text
editor.
Continued on next page

106

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Changing the Station Name, the Link Name and the IP


Address of your Station, Continued
Downloading
to IDR-C

To download the config.sys and boot.sys files from the LCT to the
IDR-C, follow the steps below:
Step
1
2
3
4
5
6
7
8
9
10
11

Action
Select Start>Run and type command in the Open box.
At the DOS prompt, enter FTP xxx where xxx is the current
IP address of the station, and then press ENTER.
Type the username and the password, and then press
ENTER. By default, the username is aris and the password
is akand.
Type del config.sys, and then press ENTER to delete the
config.sys file that is stored in the IDR-C.
Type del boot.sys, and then press ENTER to delete the
boot.sys file that is stored in the IDR-C.
Type lcd dirname, where dirname is the name of the folder
you have created in the disk of your LCT, and then press
ENTER.
Type put config.sys, and then press ENTER to transfer the
modified config.sys file from the folder of the LCT to the IDRC and store it in the IDR-C.
Type put boot.sys, and then press ENTER to transfer the
modified boot.sys file from the folder of the LCT to the IDR-C
and store it in the IDR-C.
Type bye, and then press ENTER to return to the DOS
prompt.
Type exit, and then press ENTER to return to Windows.
Press the reset button on the front panel of the IDR-C to
reset the IDR-C or switch-off the IDR-C. The IP address of
the station will be the one you typed in the relevant field of
the config.sys and boot.sys files. The link name and the
station name will have also been changed accordingly.

107

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Annex C: Example of Router Configuration


Example
scenario

The scenario of the example is the following:


We want to connect an LCT to a chain of IDR-C stations through an IP
network. The IP address of the router in the example is
146.124.34.141 while the IP address of the IDR-C system connected
to the router through the asynchronous port NMS1 is 192.168.51.29.
Router

NMS1
Port
146.124.34.141

Ethernet
Connection

IDR-C
1

IDR-C
2

NMS1
Port

192.168.51.29

IP
Network
Ethernet
Connection

LCT

Configuring
the router

IDR-C
4

IDR-C
3

NMS1
Port

In the aforementioned configuration, the router is equipped with the


WIC-2T card and is connected to the IDR-C station through its Serial0
port and to the IP network through its Fast Ethernet0 port. To
configure the router, type the following commands:
! Commands for the FastEthernet0 interface configuration:
interface FastEthernet0
ip address 146.124.34.141 255.255.255.0
no ip redirects
no ip proxy-arp
speed auto

! Commands for the Loopback0 interface configuration; to ensure


unified ip addressing on the asynchronous serial ports:
interface Loopback0
ip address 192.168.51.254 255.255.255.255

! Commands for the Serial0 interface configuration (the Serial0


interface has been configured to use the IP address of the Loopback0
interface):
interface Serial0
physical-layer async
mtu 400
ip unnumbered Loopback0
Continued on next page

108

IDR-C_LCT_UserManual_04

IDR-C LCT User Manual

Annex C: Example of Router Configuration, Continued


Configuring
the router
(continued)

encapsulation ppp
keepalive 10
async default routing
async mode dedicated
line 1
transport input all
stopbits 1
speed 57600
router rip
version 2
redistribute connected
redistribute static
passive-interface FastEthernet0
network 192.168.51.0

! Command to inject the default route information across the RIP


enabled nodes:
default-information originate

!
no auto-summary
no ip classless

! Command to configure the default route (gateway of last resort):


ip route 0.0.0.0 0.0.0.0 146.124.34.100

!
no ip http server
line con 0
login
transport input none

! Commands to configure the Serial0 interface. The interface baud rate


should be fixed at 57600 bit/s.
line 1
transport input all
stopbits 1
speed 57600

!
line aux 0
line vty 0 4
password idr-test
login
end

109

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Annex D: Default Alarms Attributes


1+0 Topology
Group

Name

Radio
LD_RX
Radio
LD_TX
Radio
RSSI_RX
Radio
LD_DDS
Radio
ALC
Radio
LDLoopBack
Radio
RSSI_Thrs
Radio
Tmprt_Thrs
Framer
BERR6
Framer
LFA
General Radio_comm
General
PS
External inputs 1,2,3,4

Sent to
Output
3
3
3
3
3
3
3
3
2
2
1
1
4

Logged

Severity

Polarity

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor

Reverse
Reverse
Reverse
Reverse
Normal
Reverse
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Continued on next page

110

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Annex D: Default Alarms Attributes, Continued


1+1 Topology
Group

Name

Radio
RALD_RX
Radio
RALD_TX
Radio
RARSSI_RX
Radio
RALD_DDS
Radio
RA_ALC
Radio RALDLoopBack
Radio
RA_RSSI_Thrs
Radio RA_Tmprt_Thrs
Radio
RBLD_RX
Radio
RBLD_TX
Radio
RBRSSI_RX
Radio
RBLD_DDS
Radio
RB_ALC
Radio RBLDLoopBack
Radio
RB_RSSI_Thrs
Radio RB_Tmprt_Thrs
Framer
FABERR6
Framer
FALFA
Framer
FBBERR6
Framer
FBLFA
General
Radio_comm1
General
Radio_comm2
General
PS1
General
PS2
External inputs 1,2,3,4

Sent to
Output
3
3
3
3
3
3
3
3
3
3
3
3
3
3
2
2
2
2
1
1
1
1
4

Logged

Severity

Polarity

Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes

Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor
Minor

Reverse
Reverse
Reverse
Reverse
Normal
Reverse
Normal
Normal
Reverse
Reverse
Reverse
Reverse
Normal
Reverse
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal
Normal

111

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Annex E: Changing the IDR-C Capacity and Modulation (for


the advanced User only)
Prerequisites

Before changing the IDR-C capacity and modulation, do the following:


Step
1

Action
Use the FTP Tool of the System menu and check the
following files are stored in the CMS unit of your IDR-C. If
the files are not stored in the CMS unit, download them from
the IDR-C Operation CD-ROM as described on page 116.
bin files
sdhv139_chk.bin
idrc_2.3.1.bin
xsvf files
fload_v1.xsvf
qam16_16x2_v2.xsvf
qam16_8x2_v2.xsvf
qam16_4x2_v2.xsvf
qpsk_16x2_v2.xsvf
qpsk_8x2_v2.xsvf
qpsk_4x2_v2.xsvf
sys files
config.sys
boot.sys
mib files
idrc_v0.8.mib
Open the Versions tabbed sheet and check the ODU
version(s) is(are) the 0139. If the version is not the 0139,
update the ODU(s) version, as described on page 118.
Continued on next page

112

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Changing the IDR-C Capacity and Modulation (for the


advanced User only), Continued
Prerequisites (continued)

Step
3

Action
Remove the IDR-C back cover and strap the pins at the
backplane connector as shown in the figure below. Place the
cover back on again.

Continued on next page

113

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Changing the IDR-C Capacity and Modulation (for the


advanced User only), Continued
Procedure

To change the IDR-C capacity and modulation, follow the steps below:
Step
1
2

3
4
5

Action
Get connected to the IDR-C.
Select Start>Run and in the Open box, type telnet <ip
address> where <ip address> is the ip address of the IDR-C
station whose the capacity and modulation you want to
change.
Type nick as login and nman as password and press
ENTER.
Type ls and press ENTER. You view all the files of the CMS
card.
Type Xupdate <xsvf file> a where <xsvf file> is one of the
following files depending on the required capacity &
modulation and a is 1 for modem A and 2 for modem B. With
this command, you download the appropriate code file to the
modem(s) ROM.
qam16_16x2_v2.xsvf
qam16_8x2_v2.xsvf
qam16_4x2_v2.xsvf
qpsk_16x2_v2.xsvf
qpsk_8x2_v2.xsvf
qpsk_4x2_v2.xsvf
Example: If the capacity and modulation you require is 16 x
2 Mbit/s QAM, you should type:
Xupdate qam16_16x2_v2.xsvf 1

The procedure lasts about 10 minutes.


Continued on next page

114

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Changing the IDR-C Capacity and Modulation (for the


advanced User only), Continued
Procedure (continued)

Step
6

Action
Type Xupdate fload_v1.xsvf a where a is 1 for modem A and
2 for modem B. With this command, you make the
modem(s) operate with the specific capacity and modulation.

7
8

Type exit and press ENTER to exit telnet.


Delete from the CMS unit the existing system.ini file and
download to the CMS unit the appropriate system.ini file
relative to the new modulation and capacity as described on
page 116.
Switch-off and on the IDR-C to reset the system.
Open the ODU tabbed sheet and click Reset ODU to reset
the ODU.
Open the System tabbed sheet and confirm the values of
the System Capacity and Modulation boxes have changed
properly.

9
10
11

115

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Downloading the required Files to the CMS Unit


To download the required files to the CMS unit, follow the steps below:
Step
1
2

3
4
5
6
7

Action
Create a folder in the disk of your LCT (e.g. temp1).
Insert the IDR-C Operation CD-ROM in the disk drive and
copy the files you want to download to the CMS unit from
the System Files folder of the CD-ROM to the folder you
created in the previous step. Especially for the system.ini
file, select to copy the system.ini file appropriate for the
capacity and modulation you want to achieve and for the
topology (1+0 or 1+1) you have.
Note: The format of the system.ini file is as follows:
<capacity>_<modulation>_<topology>_system.ini
(e.g. 4x2_qpsk_1+0_system.ini)
After you copy it to the LCT folder you must rename it to
system.ini file (i.e. do not maintain the name
<capacity>_<modulation>_<topology>_system.ini).
Select Start>Run and type command in the Open box.
At the DOS prompt, type FTP xxx where xxx is the IP
address of the station, and then press ENTER.
Type the username (aris) and the password (akand), and
then press ENTER.
Type lcd dirname where dirname is the name of the folder
you created (e.g. lcd c:\temp1), and then press ENTER.
Type hash to have a dotted view of the process progress.
Continued on next page

116

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Downloading the required Files to the CMS Unit, Continued

Step
8

10
11
12
13

Action
Type del <filename> where filename is one of the following,
and then press ENTER to delete the specific file from the
CMS unit.
bin files
sdhv139_chk.bin
idrc_2.3.1.bin
xsvf files
fload_v1.xsvf
qam16_16x2_v2.xsvf
qam16_8x2_v2.xsvf
qam16_4x2_v2.xsvf
qpsk_16x2_v2.xsvf
qpsk_8x2_v2.xsvf
qpsk_4x2_v2.xsvf
sys files
config.sys
boot.sys
mib files
idrc_v0.8.mib
ini files
system.ini
Type put <filename>, and then press ENTER to download
the specific file from the folder of the LCT to the CMS unit.
Note: You do not need to download all the xsvf files to the
CMS unit. Download only the fload_v1.xsvf and the xsvf of
the capacity and modulation you want to achieve.
Repeat steps 8 and 9 for as many files as needed.
Type bye, and then press ENTER to return to the DOS
prompt.
Type exit, and then press ENTER to return to Windows.
Press the reset button on the front panel of the IDR-C to
reset the IDR-C or switch-off the IDR-C.

117

IDR-C LCT User Manual

IDR-C_LCT_UserManual_04

Updating the ODU Version


To update the ODU version to 0139, follow the steps below:
Step
1
2
3
4
5

Action
Download the sdhv139_chk.bin file from the IDR-C
Operation CD-ROM to the CMS unit as described on page
116.
Select Start>Run and in the Open box, type telnet <ip
address> where <ip address> is the ip address of the IDR-C
station whose the ODU version you want to update.
Type nick as login and nman as password and press
ENTER.
Type ls and press ENTER. You view all the files of the CMS
card.
Type ODUupdate sdhv139_chk.bin 0 (for ODU A) or 1 (for
ODU B) and press ENTER.

The ODU update process lasts about 7 minutes. After the


process completion, the following screen appears:

118