HEAT LOAD ESTIMATE

PROJECT
LOCATION
CLIENT
CONSULTANT
Date
Item

Area or
Quantity

Sun Gain or
Temp. Diff.

Factor

ROOM HEAT
ROOM SENSIBLE HEAT
Solar Gain - Glass
Glass - N
SqFt x
F
x
Glass - NE
SqFt x
F
x
Glass - E
SqFt x
F
x
Glass - SE
SqFt x
F
x
Glass - S
SqFt x
F
x
Glass - SW
SqFt x
F
x
Glass - W
SqFt x
F
x
Glass - NW
SqFt x
F
x
Skylight
SqFt x
F
x
Solar & Transmission Gain - Walls & Roof
Wall - N
SqFt x
F
x
Wall - NE
SqFt x
F
x
Wall - E
SqFt x
F
x
Wall - SE
SqFt x
F
x
Wall - S
SqFt x
F
x
Wall - SW
SqFt x
F
x
Wall - W
SqFt x
F
x
Wall - NW
SqFt x
F
x
Roof
SqFt x
F
x
Transmission Gain - Except Walls & Roof
All Glass
0
SqFt x
30
F
x
Partition
SqFt x
F
x
Ceiling
SqFt x
F
x
Floor
SqFt x
F
x
INFILTRATION AND BY PASSED AIR
Infiltration
CFM x
30 T.Diff
x
1.08
Ventillation
CFM x
30 T.Diff
x BF x 1.08
Internal Heat
People
Nos. x
Btu/Hour Per Person
Lighting
SqFt x
W/SqFt
x
3.41
Lighting & S. P.
SqFt x
W/SqFt
x
3.41
Equipment
kW x
3410
Sub Total
Factor
5-10%
Effective Room Sensible Heat
ROOM LATENT HEAT
Infiltration
CFM x
32 Gr/Lb
x
0.68
Outside Air
CFM x
32 Gr/Lb
x BFx0.68
People
Nos. x
Btu/Hour Per Person
Sub Total
Factor
2.5 - 5%
Effective Room Latent Heat
EFFECTIVE ROOM TOTAL HEAT
OUTSIDE AIR HEAT
Sensible
CFM x
30 F(TD)
x CF x 1.08
Latent
CFM x
32 Gr/Lb
x CF x 0.68
OUTSIDE AIR TOTAL HEAT
GRAND TOTAL HEAT
Sub Total
TONS=GRAND TOTAL HEAT/12000

Btu/Hour

FLOOR
SPACE REFERENCE
AREA ( SqFt)
Height (Ft)
Volume (CuFt)
Estimate for
Design Conditions
Ambient
Room
Difference

Summer
DB (F)
106
76
30

WB (F)
78
63.5
14.5

RH (%)
28
50
-22

SH Gr/Lb
100
68
32

By Pass Factor (BF)


Contact Factor (CF = 1 - BF)
CFM Ventilation

=
=

CFM Per Person


No
=
CFM Per SqFt
0 Sqft
x
Air Change Per Hour (CFM)
=
CFM
Cu.ft
x
CFM Infiltration

=
=

Swinging
Revolving Doors (People)
Open Doors
Crack
(feet)

x
x
x
x

x1/60

cfm/door
cfm/door
cfm/door
cfm/ft

=
=
=
=

Supply CFM from Machine


Effective Room Sensible Heat Factor =
Effective Room Sensible Heat/Eff Room Total Heat
Apparatus Dew Point (ADP)

Indicated ADP (F)


Selected ADP (F)

=
=
Dehumidified Rise

(Room DB - ADP) x CF
DEHUMIDIFIED AIR QUANTITY
Effective Room Sensible Heat
Dehumidified Rise x 1.08

=
=

=
TOTAL HEAT CAPACITY
Grand Total Heat

=
=
=

SENSIBLE HEAT CAPACITY


Grand Sensible Heat
12000

=
=

=
Check Figures:
SqFt Per TR
Btu/Hour Per SqFt
Dehumidified CFM Per SqFt
Dehumidified CFM Per TR
Notes:

=
=
=
=

Summer
SH Gr/Lb
100
68
32

CFM Ventilation
0
0
0
CFM Infiltration
Supply CFM from Machine

Apparatus Dew Point (ADP)

Dehumidified Rise

CFM

L/s
TR
MBH
kW
TR
MBH

kW