Sie sind auf Seite 1von 1

ZTE eReader-Search results

Page 1 of 1

Record1-5 of 5
Document Type: Operation guide(2) Reference(3)
1

ZGO-04-04-002 Load Dependent Intelligent TRX Shutdown [ Operation guide ]


ZGO-04-04-002 Load Dependent Intelligent TRX Shutdown Prerequisite The Configuration Management tab is open. Context ZXG10
iBSC notifies the BTS to perform power-on/power-off operation through a message when the performance data crosses the poweron/power-off threshold. ZXG10 iBSC combines multiple scattered timeslots and migrates them to the fewest...
ZXG10 iBSC (V6.20.71) User Manual Library/Operation and Maintenance/Feature Configuration Guide/Network Performance/Lower Power
Consumption/ZGO-04-04-002 Load Dependent Intelligent TRX Shutdown 100%

Lower Power Consumption [ Operation guide ]


... Consumption Children topic: ZGO-04-04-001 TCH Migration to BCCH TRX ZGO-04-04-002 Load Dependent Intelligent TRX Shutdown
ZGO-04-04-003 Intelligent Timeslot Shutdown ZGO-04-04-004 PA Voltage Adjustment ZGO-04-04-007 Intelligent Cell Shutdown ZGO-0404-008 Intelligent BCCH Power Reduction ZGO-04-04-006 Intelligent TRX Shutdown Triggered by Main Power...
ZXG10 iBSC (V6.20.71) User Manual Library/Operation and Maintenance/Feature Configuration Guide/Network Performance/Lower Power
Consumption 61%

The method of intelligent TRX poweroff (Info_0_0) [ Reference ]


... Mode Offline Related features ZGO-04-04-002--Load Dependent Intelligent TRX Shutdown Related Parameters None Relationship
None Related Interfaces None Impact on Equipment 0 Impact on service 0 Negotiation With CN NO OMC Access Path OMC->GERAN
Subnetwork ID->BSC Managed element ID->Config set ID->BSC Function->Set Systerm Control Parameter->IBS Parameters...
ZXG10 iBSC (V6.20.71) User Manual Library/Reference/Radio Parameter Reference/System Control Parameters/IBS Parameters/The method
of intelligent TRX poweroff (Info_0_0) 54%

TRX PowerOff time bitmap (DownPowerBmp) [ Reference ]


... Mode Offline Related features ZGO-04-04-002 Load Dependent Intelligent TRX Shutdown Related Parameters None Relationship
None Related Interfaces None Impact on Equipment 0 Impact on service 0 Negotiation With CN NO OMC Access Path OMC->GERAN
Subnetwork ID->BSC Managed element ID->Config set ID->BSC Function ID->Site config->Site ID->Cell ID->Basic ...
ZXG10 iBSC (V6.20.71) User Manual Library/Reference/Radio Parameter Reference/Cell Parameters/Basic Parameters 2/TRX PowerOff time
bitmap (DownPowerBmp) 33%

Switch flag of cell TRX power off (StartTRXPowerOff) [ Reference ]


... Mode Offline Related features ZGO-04-04-002 Load Dependent Intelligent TRX Shutdown Related Parameters None Relationship
None Related Interfaces None Impact on Equipment 0 Impact on service 0 Negotiation With CN NO OMC Access Path OMC->GERAN
Subnetwork ID->BSC Managed Element ID->Config Set ID->BSC Function ID->Site Config->Site ID->Cell ID->Basic ...
ZXG10 iBSC (V6.20.71) User Manual Library/Reference/Radio Parameter Reference/Cell Parameters/Basic Parameters 2/Switch flag of cell
TRX power off (StartTRXPowerOff) 33%
Search in the results

Page

/1

5 record(s) in total

1998-2014 ZTE Corporation. All rights reserved

http://127.0.0.1:8890/web/searchinfo.html?rand=0.2587801199159789&selected=1&...