Sie sind auf Seite 1von 65

Saudi Arabia

General Wall Mounted


60Hz(R22)
SR-6RMG2-02A

GENERAL WALL MOUNTED


Contents
1. Models Line up .............................................................................6
2. Nomenclature ...............................................................................7
3. Features & Benefits......................................................................8
4. Specifications .............................................................................10
5. Dimensional Drawings...............................................................17
6. Wiring Diagrams.........................................................................22
7. Refrigerant Cycle Diagram ........................................................33
8. Capacity Tables ..........................................................................34
9. Capacity Coefficient factor........................................................41
10. Air Velocity and Temperature Distribution
(Reference Data).......................................................................43
11. Controller ..................................................................................44
12. Installation ................................................................................47

GENERAL WALL MOUNTED

SR-6RMG2-02A

Test condition of international standard


KSC
9306

ISO
5151

ARI
210/240

AHAM

AS
1861.1

SSA
385

DBC(F)

27.0

27.0

26.7(80)

26.7(80)

27.0

29.0

WBC(F)

19.5

19.0

19.4(67)

19.4(67)

19.0

19.0

DBC(F)

35.0

35.0

35.0(95)

35.0(95)

35.0

46.0

WBC(F)

24.0

24.0

23.9(75)

23.9(75)

24.0

24.0

DBC(F)

20.0

20.0

21.1(70)

21.1(70)

21.0

21.0

WBC(F)

15.0

15.0

15.6(60)

15.6(60)

15.0

15.5

DBC(F)

7.0

7.0

8.3(47)

8.3(47)

7.0

7.0

WBC(F)

6.0

6.0

6.1(43)

6.1(43)

6.0

6.0

DBC(F)

32.0

32.0

26.7(80)

32.2(90)

32.0

29.0

WBC(F)

23.0

23.0

19.4(67)

22.8(73)

23.0

19.0

DBC(F)

43.0

43.0

46.1(115)

43.3(110)

43.0

54.0

WBC(F)

26.0

26.0

23.9(75)

25.6(78)

26.0

24.0

DBC(F)

27.0

27.0

26.7(80)

26.7(80)

WBC(F)

19.0

19.0

19.4(67)

22.8(73)

DBC(F)

21.0

24.0

23.9(75)

23.9(75)

WBC(F)

15.0

18.0

18.3(65)

18.3(65)

DBC(F)

27.0

27.0

26.7(80)

26.7(80)

27.0

27.0

WBC(F)

24.0

24.0

23.9(75)

23.9(75)

24.0

24.0

DBC(F)

27.0

27.0

26.7(80)

26.7(80)

27.0

27.0

WBC(F)

24.0

24.0

23.9(75)

23.9(75)

24.0

24.0

DBC(F)

21.0

21.0

19.4(67)

21.1(70)

21.0

21.0

WBC(F)

15.0

15.0

13.9(57)

15.6(60)

16.0

16.0

DBC(F)

21.0

21.0

19.4(67)

21.1(70)

21.0

21.0

WBC(F)

15.0

15.0

13.9(57)

15.6(60)

16.0

16.0

CLASSIFICATION
Indoor
Cooling
Capacity

Outdoor

Indoor
Heating
Capacity

Maximum

Outdoor

Indoor

Cooling
Operating

Outdoor

Maximum

Indoor

Heating
Operating
Enclosure

Outdoor

Indoor

Sweat /
Condensate

Outdoor

Disposal
Freeze-up/

Indoor

Low
Temperature Outdoor

KS : Korea Standard
ISO : International Standard Organization
ARI : Airconditioning and Refrigeration Institute
AHAM : Association of Home Appliance Manufacturers

AS : Australia Standard
SSA : Saudi Arabian Standard

GENERAL WALL MOUNTED

SR-6RMG2-02A

General Description
Split type of Air Conditioners are known by the category name of Wall Mounted Type of units.These units can be
easily installed in a small space and have exceptional Cooling capacity.Designed for Low-noise operation,it
ensures a pleasant air conditioned environment.
LG Offers various types of units to its customers to suit for the best application and requirement.The following are
the important categories offered by LG :
1) General Wall Mounted Type Units : Units with Simplicity in design.
2) Art Cool Units : A new concept of cooling introduced by LG in the field of Air Conditioning.
3) New Gas Models : These models uses HCFC free refrigerant to provide a healthy environment to the world.
Some of the Important Features of these units are listed below :
1) Providing Health to the Customers : By having Filters such as Plasma Filter which is capable of removing Micro
Organisms up to 0.1 microns.
2) Long Term Money Saving : By providing Features such as Gold Fin,Plasma Fin, Auto Clean etc. to maintain the
same performance for years.
3) Best Comfort : With Features such as Sleep Mode,Timer,Auto Restart etc.
These Units are available with many standard and optional features which gives our Customers the choice to select
the unit of their own desire.For details refer to the Detailed specification followed after this description.

LG Electronics Inc.
Air Conditioning & Energy Solution Company

GENERAL WALL MOUNTED

SR-6RMG2-02A

Publication history
PDB No.

Product Name

Notes

Publication in

SR-6RMG2-01A

SRAC

4Models

Dec. 2012

SR-6RMG2-02A

SRAC

10 Models

May. 2013

GENERAL WALL MOUNTED

Models Line up

SR-6RMG2-02A

1. Models Line up
General Wall Mounted
Edition

Capacity

Chassis

18K

SC

24K

SC

12K

SE

18K

S5

24K

S5

#1

#2

Type

Factory Model

Buyer Model

C/O
H/P
C/O
H/P
C/O
H/P
C/O
H/P
C/O
H/P
C/O
H/P
C/O
H/P

GS-C182C4B2
GS-H182C4B2
GS-C242C4B2
GS-H242C4B2
GS-C122E5B2
GS-H122E5B2
GS-C1825SA3
GS-H1825SA3
GS-C1825NB2
GS-H1825NB2
GS-C2425SA3
GS-H2425SA3
GS-C2425NB2
GS-H2425NB2

S122NC
S122NH
S182SC
S182SH
S182NC
S182NH
S242SC
S242SH
S242NC
S242NH

GENERAL WALL MOUNTED

SR-6RMG2-02A

Nomenclature

2. Nomenclature
Identification Rule
G

Serial Number
Function
B: 4Way
Look/Color
Chassis
SC

Look
4

Classification
ICE-E (White)

Chassis Name
C: SC
Electric Rating
2: 220V, 60Hz
Capacity
EX) '18' 18,000Btu/h Class
Model Type
C: Cooling Only
H: Heat Pump
Supply Method Diving and Type
-: SET
Product Type
S: Split
Refrigerant Type
G: R22

GENERAL WALL MOUNTED

Features & Benefits

SR-6RMG2-02A

3. Features & Benefits

Stylish
Design



Smoke
Away

Gold
Fin

Tropical
Compressor

;SM_.IV

Quick & Easy


Installation

Skew Fan

Dual
Protection Filter

Vane &
Louver

Extreme Durability
The combination of tropical compressor,
and the gold fin in the exterior unit all
contribute in the improved durability of LG air
conditioner.



The advanced tropical compressor withstands


extreme weather conditions, enabling the
product to operate despite high outside temperature.
By adopting gold plated fins in the exterior
unit, the heat exchanger is protected from corrosion and wear from external conditions.

GENERAL WALL MOUNTED

SR-6RMG2-02A

Features & Benefits

Power Cooling
The cool airflow reaches the
distance of 15m to all corners of
the room, keeping the space cool
and comfortable regardless of
outside temperature.

20m Windblast : Strong and cool windblast


covers the distance of 20m.

Optimized Airflow : The interior of the compressor in the outdoor unit has been constructed to minimze the sound produced when operating.

Smoke Away : 3 million ions


spread from diffusion charger and 3M Micro
Protection filter remove smoke particle as
much as air-purifier removes.

Perfect Health Care


Various filtration system protects the user
from all harmful substances including odor,
bacteria, and allergen

* Test Results
Size of Area : 30m3, CADR : 135

Dual Protection Filter : Dual Protection Filter


initially captures dust in the air that comes in
to the air conditioner.
3M Multi Protection Filter : 3M Multi
Protection filter captures dust, virus and allergen and deactivates the captured virus and
allergen by unique technologies of LG and 3M.
Filter : While being easy to maintain, the powerful plasma filtration system of
LG air conditioner protects the user from odor
and any harmful substances floating in air.

Energy Saving
State of the art heat exchanger, air outlet,
compressor, and inverter technology provide
the worlds highest energy efficiency

Inverter V : The advanced inverter technology


of LG enables the user of the air conditioner to
use more and save more.

Stylish Design
LG air conditioners are not just refreshingly
efficient, but also exceptionally elegant in
design

The design of LG air conditioners are stylish in


a way that is incomparable to others. Think of
it not just as an air conditioner, but an objet
that will lighten up your living room.

Quick & Easy Installation


Installation has never been easier as with the
delicately designed installation elements of
LG air conditioners

Perfect finishing / Bigger tubing space / Installation


plate improvement / Detachable bottom cover /
Elevated service valve / Installation support clip /
Compatible with inverter multi system

GENERAL WALL MOUNTED

Specifications

SR-6RMG2-02A

4. Specifications
General Wall Mounted(#1)
Model Name (LG)
Pet Name
Cooling Capacity (T1)
Heating Capacity (H1)
Power Input Normal
Running Current
(Normal)

Cooling
Heating
Cooling
Heating

EER
COP
Power Factor

Cooling
Heating

Cooling Capacity (T3)


Power Input (T3)
Running Current (T3)
EER
Power Factor
Power Input (Max)
Running Current
(Max)
Power Factor

Cooling
Heating
Cooling
Heating
Cooling
Heating

Power Supply
Air Circulation

Indoor
Outdoor

Moisture Removal
Noise Level
(SoundPressure,1m)

Indoor
Outdoor

Refrigerant Charge

Compressor

Blower Motor
Fan Motor

Type
Model
Maker
Capacity
Motor Type
Motor Input
Oil Type
Oil Charge
O.L.P Name
Type
Output
Type
Motor Type
Motor Output

Circuit Breaker
Power Cord
Connecting Cable
Connecting Tube
(. Socket Flare)
Drain Hose
Dimension
Net Weight
Stuffing Quantity
Tool Code

Liquid Side
Gas Side
Length,std
(O.D , I.D)
Indoor
(W*H*D)
Outdoor
(W*H*D)
Indoor
Outdoor
In+Out
In+Out

AIR FLOW

Air purifying
Reliability
Functions

Convenience

Individual
control

W
Btu/h.
W
Btu/h.
W
W
A
A
W/W
Btu/h.W
(STAR)
W/W
%
%
W
Btu/h.
W
A
W/W
Btu/h.W
%
W
W
A
A
%
%
/ V / Hz
m3/min(CFM),Max
m3/min(CFM),Max
/h.
dB(A)3,High
dB(A)3,Med
dB(A)3,Low
dB(A)3,Max
Type
g

kcal/h.(Btu/h.)
W
cc
W
W
A
AWG#:P*mm2
AWG#:P*mm2
mm(in)
mm(in)
m(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
20/40ft/HC/Truck
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Deodorizing filter (Allergy & H1N1 Filter)
Plasma air purifier
Prefilter(washable / anti-fungus)
Hot start
Self diagnosis
Soft dry operation
Setting Temperature, Cooling
Setting Temperature, Heating
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Forced operation
Sleep mode
Setting Temperature Range (Cooling)
Setting Temperature Range (Heating)
Temperature Increment
Timer(Hr)
Wireless remote controller(simple)
Wireless LCD remote control

Note:
O : Applied, - : No relation
* For circuit breaker rating, please conform to local standards wherever necessary.

10

GS-C182C4B2
Gold Plus
5,250
17,914
2,050
9.6
2.56
8.74
3
97%
4,600
15,696
2,500
11.5
1.84
6.28
98.81
2,900
13.5
97.64
1/220/60
13.0 (460)
45 (1,590)
1.9
43
40
37
56
R22
970
ROTARY
QJ278KCF
LG
5,744(19,600)
PSC
1,867
SUNISO 4GSI or NOC NM56
500
INTERNAL
Cross Flow Fan
22
Axial fan
AC Induction
64
20
3x1.5
3x1.5
6.35(1/4")
15.88(5/8")
5(196)
21.5,16 (0.85,0.63)
1030*320*245
40.5*12.6*9.6
870*655*320
34.25*25.79*12.6
12.6(27.8)
40.5(89.3)
57/124/139/SC+UE
1
Auto
Auto
Auto
Auto
3/4/Yes
Yes
Yes
Yes
Yes
Yes
18 - 30
Yes
Yes
Yes
Yes
Yes
18-30
16-30
1
Yes (24h On/Off)
Yes(Type1)

GS-H182C4B2
Gold Plus
5,130
17,504
5,250
17,914
2,150
1,750
10.0
8.0
2.39
8.14
2
3.00
98%
99%
4,450
15,184
2,450
11.5
1.82
6.20
96.84
2,900
1,890
13.5
8.9
97.64
96.53
1/220/60
13.0 (460)
45 (1,590)
1.9
43
40
37
56
R22
970
ROTARY
QJ278KCF
LG
5,744(19,600)
PSC
1,867
SUNISO 4GSI or NOC NM56
500
INTERNAL
Cross Flow Fan
22
Axial fan
AC Induction
64
20
3x2.0
3x2.0+2x0.75
6.35(1/4")
15.88(5/8")
5(196)
21.5,16 (0.85,0.63)
1030*320*245
40.5*12.6*9.6
870*655*320
34.25*25.79*12.6
13(28.7)
42(92.6)
57/124/139/SC+UE
1
Auto
Auto
Auto
Auto
3/4/3
Yes
Yes
Yes
Yes
Yes
Yes
Yes
18 - 30
16 - 30
Yes
Yes
Yes
Yes
Yes
18-30
16-30
1
Yes (24h On/Off)
Yes(Type1)

h Some of functions are slightly different depending upon models.


h The specification may be subject to change without notic for purpose of improvement.

GENERAL WALL MOUNTED

SR-6RMG2-02A

Specifications

Model Name (LG)


Pet Name
W
Btu/h.
W
Btu/h.
W
W
A
A
W/W
Btu/h.W
(STAR)
W/W
%
%
W
Btu/h.
W
A
W/W
Btu/h.W
%
W
W
A
A
%
%
/ V / Hz
m3/min(CFM),Max
m3/min(CFM),Max
/h.
dB(A)3,High
dB(A)3,Med
dB(A)3,Low
dB(A)3,Max
Type
g

Cooling Capacity (T1)


Heating Capacity (H1)
Power Input Normal
Running Current
(Normal)

Cooling
Heating
Cooling
Heating

EER
COP
Power Factor

Cooling
Heating

Cooling Capacity (T3)


Power Input (T3)
Running Current (T3)
EER
Power Factor
Power Input (Max)
Running Current
(Max)
Power Factor

Cooling
Heating
Cooling
Heating
Cooling
Heating

Power Supply
Air Circulation

Indoor
Outdoor

Moisture Removal
Noise Level
(SoundPressure,1m)

Indoor
Outdoor

Refrigerant Charge

Compressor

Blower Motor
Fan Motor

Type
Model
Maker
Capacity
Motor Type
Motor Input
Oil Type
Oil Charge
O.L.P Name
Type
Output
Type
Motor Type
Motor Output

Circuit Breaker
Power Cord
Connecting Cable
Connecting Tube
(. Socket Flare)
Drain Hose
Dimension
Net Weight
Stuffing Quantity
Tool Code

Liquid Side
Gas Side
Length,std
(O.D , I.D)
Indoor
(W*H*D)
Outdoor
(W*H*D)
Indoor
Outdoor
In+Out
In+Out

Air flow

Air purifying
Reliability
Functions

Convenience

Individual
control

kcal/h.(Btu/h.)
W
cc
W
W
A
AWG#:P*mm2
AWG#:P*mm2
mm(in)
mm(in)
m(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
20/40ft/HC/Truck
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Deodorizing filter (Allergy & H1N1 Filter)
Plasma air purifier
Prefilter(washable / anti-fungus)
Hot start
Self diagnosis
Soft dry operation
Setting Temperature, Cooling
Setting Temperature, Heating
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Forced operation
Sleep mode
Setting Temperature Range (Cooling)
Setting Temperature Range (Heating)
Temperature Increment
Timer(Hr)
Wireless remote controller(simple)
Wireless LCD remote control

Note:
O : Applied, - : No relation
* For circuit breaker rating, please conform to local standards wherever necessary.

GS-C242C4B2
Gold Plus
6,600
22,520
2,650
12.6
2.49
8.50
3.00
96%
5,750
19,620
3,080
14.5

GS-H242C4B2
Gold Plus
6,600
22,520
6,700
22,861
2,650
2,500
12.6
12.0
2.49
8.50
3.00
2.68
96%
95%
5,750
19,620
3,080
14.5

6.37
96.55
4,000
18.5
98.28
1/220/60
16.0(566)
48 (1,695)
2.5
43
40
37
56
R22
1550
ROTARY
QP362KBB
LG
7,911(27,000)
PSC
2,571
NM56 or SUNISO 4GSI
700
INTERNAL
Cross Flow Fan
25.6
Axial fan
AC Induction
64
30
3x2.5
3x2.5
9.52(3/8")
15.88(5/8")
5(196)
21.5,16 (0.85,0.63)
1030*320*245
40.5*12.6*9.6
870*655*320
34.25*25.79*12.6
13.6(30.0)
50,5(111.33)
57/124/139/SC+UE
1
Auto
Auto
Auto
Auto
3/4/Yes
Yes
Yes
Yes
Yes
Yes
18 - 30
Yes
Yes
Yes
Yes
Yes
18-30
16-30
1
Yes (24h On/Off)
Yes(Type1)

6.37
96.55
4,000
2,900
18.5
14.0
98.28
94.16
1/220/60
16.0(566)
48 (1,695)
2.5
43
40
37
56
R22
1550
ROTARY
QP362KBB
LG
7,911(27,000)
PSC
2,571
NM56 or SUNISO 4GSI
700
INTERNAL
Cross Flow Fan
25.6
Axial fan
AC Induction
64
30
3x2.5
3x2.5+2x0.75
9.52(3/8")
15.88(5/8")
5(196)
21.5,16 (0.85,0.63)
1030*320*245
40.5*12.6*9.6
870*655*320
34.25*25.79*12.6
13.6(30.0)
50,5(111.33)
57/124/139/SC+UE
1
Auto
Auto
Auto
Auto
3/4/3
Yes
Yes
Yes
Yes
Yes
Yes
Yes
18 - 30
16 - 30
Yes
Yes
Yes
Yes
Yes
18-30
16-30
1
Yes (24h On/Off)
Yes(Type1)

h Some of functions are slightly different depending upon models.


h The specification may be subject to change without notic for purpose of improvement.

GENERAL WALL MOUNTED

11

Specifications

SR-6RMG2-02A

General Wall Mounted(#2)


Model Name (LG)
Pet Name
Cooling Capacity (T1)
Heating Capacity (H1)
Power Input Normal
Running Current
(Normal)

Cooling
Heating
Cooling
Heating

EER
COP
Power Factor

Cooling
Heating

Cooling Capacity (T3)


Power Input (T3)
Running Current (T3)
EER
Power Factor
Power Input (Max)
Running Current
(Max)
Power Factor

Cooling
Heating
Cooling
Heating
Cooling
Heating

Power Supply
Air Circulation

Indoor
Outdoor

Moisture Removal
Noise Level
(SoundPressure,1m)

Indoor
Outdoor

Refrigerant Charge

Compressor

Blower Motor
Fan Motor

Type
Model
Maker
Capacity
Motor Type
Motor Input
Oil Type
Oil Charge
O.L.P Name
Type
Output
Type
Motor Type
Motor Output

Circuit Breaker
Power Cord
Connecting Cable
Connecting Tube
(. Socket Flare)
Drain Hose
Dimension
Net Weight
Tool Code
Operation Range

Liquid Side
Gas Side
Length,std
(O.D , I.D)
Indoor
(W*H*D)
Outdoor
(W*H*D)
Indoor
Outdoor
In+Out
Cooling(Outdoor)
Heating(Outdoor)

Max. Piping Length


Max. Elevation Difference

Air flow

Air purifying
Reliability
Functions

Convenience

Individual control

GS-C122E5B2
Fresh
3,520
12,011
1,200
5.5
2.93
10.01
6
99%
3100
10,578
1400
6.5
2.21
7.56
97.90
1500
6.9
98.81
1/220/60
10
33 (1,165)
1.54
40
34
30
48
R22
850
ROTARY
QK185KBE
LG
3276 (13,000)
PSC
1215
4GSI or NM56
350
MRA12070-12027
Cross Flow Fan
15.1
Axial fan
AC Induction
41
15
3x1.0
3x1.0
6.35(1/4)
12,7(1/2")
5(196)
21.5,16(0.85,0.63)
890*282*165
32.24*11.1*6.5
770*540*245
30,31*21,25*9,64
9.0(19.8)
30.0(66.1)
SE+UL
21~54(69.8~129.2)
15(49.2)
10(33)
1
Auto
Auto
Auto
Auto
3/4/Yes
Yes
Yes
Yes
Yes
Yes
18 - 30
Yes
Yes
Yes
Yes
Yes
18-30
1
Yes (24h On/Off)
Yes(Type2)

W
Btu/h.
W
Btu/h.
W
W
A
A
W/W
Btu/h.W
(STAR)
W/W
%
%
W
Btu/h.
W
A
W/W
Btu/h.W
%
W
W
A
A
%
%
/ V / Hz
m3/min(CFM),Max
m3/min(CFM),Max
l / h.
dB(A)+3,High
dB(A)+3,Med
dB(A)+3,Low
dB(A)+3,Max
Type
g

kcal/h.(Btu/h.)
W
cc
W
W
A
AWG#:P*mm2
AWG#:P*mm2
mm(in)
mm(in)
m(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
C(F)
C(F)
m(ft)
m(ft)
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Deodorizing filter (Allergy & H1N1 Filter)
Plasma air purifier
Prefilter(Dual Protection Filter)
Hot start
Self diagnosis
Soft dry operation
Setting Temperature, Cooling
Setting Temperature, Heating
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Forced operation
Sleep mode
Setting Temperature Range (Cooling)
Setting Temperature Range (Heating)
Temperature Increment
Timer(Hr)
Wireless remote controller(simple)
Wireless LCD remote control

Note:
O : Applied, - : No relation
* For circuit breaker rating, please conform to local standards wherever necessary.

12

GS-H122E5B2
Fresh
3,372
11,506
3,520
12,011
1,200
1,150
5.5
5.3
2.81
9.59
5
3.06
99%
99%
3000
10,236
1400
6.5
2.14
7.31
97.90
1500
1350
6.9
6.2
98.81
98.97
1/220/60
10
33 (1,165)
1.45
40
34
30
48
R22
910
ROTARY
QK185KBE
LG
3276 (13,000)
PSC
1215
4GSI or NM56
350
MRA12070-12027
Cross Flow Fan
15.1
Axial fan
AC Induction
41
15
3x1.0
3x1.0+2x0.75
6.35(1/4)
12,7(1/2")
5(196)
21.5,16(0.85,0.63)
890*282*165
32.24*11.1*6.5
770*540*245
30,31*21,25*9,64
9.0(19.8)
32.0(70.5)
SE+UL
21~54(69.8~129.2)
1~24(33.8~75.2)
15(49.2)
10(33)
1
Auto
Auto
Auto
Auto
3/4/3
Yes
Yes
Yes
Yes
Yes
Yes
Yes
18 - 30
16 - 30
Yes
Yes
Yes
Yes
Yes
18-30
16-30
1
Yes (24h On/Off)
Yes(Type2)

h Some of functions are slightly different depending upon models.


h The specification may be subject to change without notic for purpose of improvement.

GENERAL WALL MOUNTED

SR-6RMG2-02A

Specifications

Model Name (LG)


Pet Name
Cooling Capacity (T1)
Heating Capacity (H1)
Power Input Normal
Running Current
(Normal)

Cooling
Heating
Cooling
Heating

EER
COP
Power Factor

Cooling
Heating

Cooling Capacity (T3)


Power Input (T3)
Running Current (T3)
EER
Power Factor
Power Input (Max)
Running Current
(Max)
Power Factor

Cooling
Heating
Cooling
Heating
Cooling
Heating

Power Supply
Air Circulation

Indoor
Outdoor

Moisture Removal
Noise Level
(SoundPressure,1m)

Indoor
Outdoor

Refrigerant Charge

Compressor

Blower Motor
Fan Motor

Type
Model
Maker
Capacity
Motor Type
Motor Input
Oil Type
Oil Charge
O.L.P Name
Type
Output
Type
Motor Type
Motor Output

Circuit Breaker
Power Cord
Connecting Cable
Connecting Tube
(. Socket Flare)
Drain Hose
Dimension
Net Weight
Tool Code
Operation Range

Liquid Side
Gas Side
Length,std
(O.D , I.D)
Indoor
(W*H*D)
Outdoor
(W*H*D)
Indoor
Outdoor
In+Out
Cooling(Outdoor)
Heating(Outdoor)

Max. Piping Length


Max. Elevation Difference

Air flow

Air purifying
Reliability
Functions

Convenience

Individual control

GS-C1825SA3
Smart
5,130
17,504
2,000
9.5
2.57
8.75
3
96%
4,500
15,355
2,300
11
1.96
6.68
95.04
2,564
12.00
97.12
1/220/60
13.0 (459)
33 (1165)
1.8
40
37
34
54
R22
720
ROTARY
QJ278KCF
LG
5,744(19,600)
PSC
1,867
4GSI or NM56
500
INTERNAL
Cross Flow Fan
20.6
Axial fan
AC Induction
41
20
3x1.5
3x1.5
6.35(1/4")
15.88(5/8")
5(196)
21.5,16 (0.85,0.63)
1090*300*180
42.9*11.8*7.09
770*540*245
30.3*21.3*9.7
11.5(25.4)
34(75.0)
S5+UL
21~54(69.8~129.2)
15(49.2)
10(33)
1
Manual
Auto
Manual
Auto
-/4/Yes
Yes
Yes
Yes
Yes
Yes
18 - 30
Yes
Yes
Yes
18-30
1
Yes (7h Off)
Yes(Type3)
-

W
Btu/h.
W
Btu/h.
W
W
A
A
W/W
Btu/h.W
(STAR)
W/W
%
%
W
Btu/h.
W
A
W/W
Btu/h.W
%
W
W
A
A
%
%
/ V / Hz
m3/min(CFM),Max
m3/min(CFM),Max
l / h.
dB(A)+3,High
dB(A)+3,Med
dB(A)+3,Low
dB(A)+3,Max
Type
g

kcal/h.(Btu/h.)
W
cc
W
W
A
AWG#:P*mm2
AWG#:P*mm2
mm(in)
mm(in)
m(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
C(F)
C(F)
m(ft)
m(ft)
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Deodorizing filter (Allergy & H1N1 Filter)
Plasma air purifier
Prefilter(Dual Protection Filter)
Hot start
Self diagnosis
Soft dry operation
Setting Temperature, Cooling
Setting Temperature, Heating
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Forced operation
Sleep mode
Setting Temperature Range (Cooling)
Setting Temperature Range (Heating)
Temperature Increment
Timer(Hr)
Wireless remote controller(simple)
Wireless LCD remote control

Note:
O : Applied, - : No relation
* For circuit breaker rating, please conform to local standards wherever necessary.

GS-H1825SA3
Smart
4,990
17,027
5,100
17,391
2,100
1,750
10.0
8.0
2.38
8.11
2
2.91
95%
99%
4,300
14,672
2,450
11.5
1.76
5.99
96.84
2,515
2,100
12.0
9.6
95.27
99.43
1/220/60
13.0 (459)
48 (1,695)
2.0
40
37
34
56
R22
1000
ROTARY
QJ278KCF
LG
5,744(19,600)
PSC
1,867
4GSI or NM56
500
INTERNAL
Cross Flow Fan
20.6
Axial fan
AC Induction
63.6
20
3x1.5
3x1.5+2x0.75
6.35(1/4")
15.88(5/8")
5(196)
21.5,16 (0.85,0.63)
1090*300*180
42.9*11.8*7.09
870*655*320
34.25*25.79*12.6
11.5(25.4)
45,5(100.3)
S5+UE
21~54(69.8~129.2)
1~24(33.8~75.2)
15(49.2)
10(33)
1
Manual
Auto
Manual
Auto
-/4/3
Yes
Yes
Yes
Yes
Yes
Yes
Yes
18 - 30
16 - 30
Yes
Yes
Yes
18-30
16-30
1
Yes (24h Off)
Yes(Type3)
-

h Some of functions are slightly different depending upon models.


h The specification may be subject to change without notic for purpose of improvement.

GENERAL WALL MOUNTED

13

Specifications

SR-6RMG2-02A

Model Name (LG)


Pet Name
Cooling Capacity (T1)
Heating Capacity (H1)
Power Input Normal
Running Current
(Normal)

Cooling
Heating
Cooling
Heating

EER
COP
Power Factor

Cooling
Heating

Cooling Capacity (T3)


Power Input (T3)
Running Current (T3)
EER
Power Factor
Power Input (Max)
Running Current
(Max)
Power Factor

Cooling
Heating
Cooling
Heating
Cooling
Heating

Power Supply
Air Circulation

Indoor
Outdoor

Moisture Removal
Noise Level
(SoundPressure,1m)

Indoor
Outdoor

Refrigerant Charge

Compressor

Blower Motor
Fan Motor

Type
Model
Maker
Capacity
Motor Type
Motor Input
Oil Type
Oil Charge
O.L.P Name
Type
Output
Type
Motor Type
Motor Output

Circuit Breaker
Power Cord
Connecting Cable
Connecting Tube
(. Socket Flare)
Drain Hose
Dimension
Net Weight
Tool Code
Operation Range

Liquid Side
Gas Side
Length,std
(O.D , I.D)
Indoor
(W*H*D)
Outdoor
(W*H*D)
Indoor
Outdoor
In+Out
Cooling(Outdoor)
Heating(Outdoor)

Max. Piping Length


Max. Elevation Difference

Air flow

Air purifying
Reliability
Functions

Convenience

Individual control

GS-C1825NB2
Fresh
5,130
17,504
2,000
9.5
2.57
8.75
3
96%
4,500
15,355
2,300
11.0
1.96
6.68
95.04
2,564
12.00
97.12
1/220/60
13.0 (459)
33 (1165)
1.8
40
37
34
54
R22
720
ROTARY
QJ278KCF
LG
5,744(19,600)
PSC
1,867
4GSI or NM56
500
INTERNAL
Cross Flow Fan
20.6
Axial fan
AC Induction
41
20
3x1.5
3x1.5
6.35(1/4")
15.88(5/8")
5(196)
21.5,16 (0.85,0.63)
1090*300*180
42.9*11.8*7.09
770*540*245
30.3*21.3*9.7
11.5(25.4)
34(75.0)
S5+UL
21~54(69.8~129.2)
15(49.2)
10(33)
1
Auto
Auto
Auto
Auto
3/4/Yes
Yes
Yes
Yes
Yes
Yes
18 - 30
Yes
Yes
Yes
Yes
Yes
18-30
1
Yes (24h On/Off)
Yes(Type2)

W
Btu/h.
W
Btu/h.
W
W
A
A
W/W
Btu/h.W
(STAR)
W/W
%
%
W
Btu/h.
W
A
W/W
Btu/h.W
%
W
W
A
A
%
%
/ V / Hz
m3/min(CFM),Max
m3/min(CFM),Max
l / h.
dB(A)+3,High
dB(A)+3,Med
dB(A)+3,Low
dB(A)+3,Max
Type
g

kcal/h.(Btu/h.)
W
cc
W
W
A
AWG#:P*mm2
AWG#:P*mm2
mm(in)
mm(in)
m(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
C(F)
C(F)
m(ft)
m(ft)
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Deodorizing filter (Allergy & H1N1 Filter)
Plasma air purifier
Prefilter(Dual Protection Filter)
Hot start
Self diagnosis
Soft dry operation
Setting Temperature, Cooling
Setting Temperature, Heating
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Forced operation
Sleep mode
Setting Temperature Range (Cooling)
Setting Temperature Range (Heating)
Temperature Increment
Timer(Hr)
Wireless remote controller(simple)
Wireless LCD remote control

Note:
O : Applied, - : No relation
* For circuit breaker rating, please conform to local standards wherever necessary.

14

GS-H1825NB2
Fresh
5,130
17,504
5,250
17,914
2,050
1,750
9.8
8.0
2.50
8.54
3
3.00
95%
99%
4,450
15,184
2,450
11.5
1.82
6.20
96.84
2,515
2,100
12.0
9.6
95.27
99.43
1/220/60
13.0 (459)
48 (1,695)
2
40
37
34
56
R22
1000
ROTARY
QJ278KCF
LG
5,744(19,600)
PSC
1,867
4GSI or NM56
500
INTERNAL
Cross Flow Fan
20.6
Axial fan
AC Induction
63.6
20
3x1.5
3x1.5+2x0.75
6.35(1/4")
15.88(5/8")
5(196)
21.5,16 (0.85,0.63)
1090*300*180
42.9*11.8*7.09
870*655*320
34.25*25.79*12.6
11.5(25.4)
45,5(100.3)
S5+UE
21~54(69.8~129.2)
1~24(33.8~75.2)
15(49.2)
10(33)
1
Auto
Auto
Auto
Auto
3/4/3
Yes
Yes
Yes
Yes
Yes
Yes
Yes
18 - 30
16 - 30
Yes
Yes
Yes
Yes
Yes
18-30
16-30
1
Yes (24h On/Off)
Yes(Type2)

h Some of functions are slightly different depending upon models.


h The specification may be subject to change without notic for purpose of improvement.

GENERAL WALL MOUNTED

SR-6RMG2-02A

Specifications

Model Name (LG)


Pet Name
Cooling Capacity (T1)
Heating Capacity (H1)
Power Input Normal
Running Current
(Normal)

Cooling
Heating
Cooling
Heating

EER
COP
Power Factor

Cooling
Heating

Cooling Capacity (T3)


Power Input (T3)
Running Current (T3)
EER
Power Factor
Power Input (Max)
Running Current
(Max)
Power Factor

Cooling
Heating
Cooling
Heating
Cooling
Heating

Power Supply
Air Circulation

Indoor
Outdoor

Moisture Removal
Noise Level
(SoundPressure,1m)

Indoor
Outdoor

Refrigerant Charge

Compressor

Blower Motor
Fan Motor

Type
Model
Maker
Capacity
Motor Type
Motor Input
Oil Type
Oil Charge
O.L.P Name
Type
Output
Type
Motor Type
Motor Output

Circuit Breaker
Power Cord
Connecting Cable
Connecting Tube
(. Socket Flare)
Drain Hose
Dimension
Net Weight
Tool Code
Operation Range

Liquid Side
Gas Side
Length,std
(O.D , I.D)
Indoor
(W*H*D)
Outdoor
(W*H*D)
Indoor
Outdoor
In+Out
Cooling(Outdoor)
Heating(Outdoor)

Max. Piping Length


Max. Elevation Difference

Air flow

Air purifying
Reliability
Functions

Convenience

Individual control

GS-C2425SA3
Smart
6,450
22,008
2,500
11.6
2.58
8.80
3
98%
5,600
19,108
3,000
13.9
1.87
6.37
98.10
3,400
16.0
96.59
1/220/60
15.0(530)
48 (1,695)
2.8
44
40
36
56
R22
900
ROTARY
QP362KBB
LG
7,911(27,000)
PSC
2,571
4GSI or NM56
700
INTERNAL
Cross Flow Fan
30
Axial fan
AC Induction
63.6
30
3x2.5
3x2.5
9.52(3/8")
15.88(5/8")
5(196)
21.5,16 (0.85,0.63)
1090*300*180
42.9*11.8*7.09
870*655*320
34.25*25.79*12.6
12.0(26.5)
42,0(92.6)
S5+UE
21~54(69.8~129.2)
15(49.2)
10(33)
1
Manual
Auto
Manual
Auto
-/4/Yes
Yes
Yes
Yes
Yes
Yes
18 - 30
Yes
Yes
Yes
18-30
1
Yes (7h Off)
Yes(Type3)
-

W
Btu/h.
W
Btu/h.
W
W
A
A
W/W
Btu/h.W
(STAR)
W/W
%
%
W
Btu/h.
W
A
W/W
Btu/h.W
%
W
W
A
A
%
%
/ V / Hz
m3/min(CFM),Max
m3/min(CFM),Max
l / h.
dB(A)+3,High
dB(A)+3,Med
dB(A)+3,Low
dB(A)+3,Max
Type
g

kcal/h.(Btu/h.)
W
cc
W
W
A
AWG#:P*mm2
AWG#:P*mm2
mm(in)
mm(in)
m(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
C(F)
C(F)
m(ft)
m(ft)
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Deodorizing filter (Allergy & H1N1 Filter)
Plasma air purifier
Prefilter(Dual Protection Filter)
Hot start
Self diagnosis
Soft dry operation
Setting Temperature, Cooling
Setting Temperature, Heating
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Forced operation
Sleep mode
Setting Temperature Range (Cooling)
Setting Temperature Range (Heating)
Temperature Increment
Timer(Hr)
Wireless remote controller(simple)
Wireless LCD remote control

Note:
O : Applied, - : No relation
* For circuit breaker rating, please conform to local standards wherever necessary.

GS-H2425SA3
Smart
6,300
21,496
6,650
22,691
2,700
2,600
12.6
12.0
2.33
7.96
2
2.56
97%
98%
5,400
18,426
3,250
15.2
1.66
5.67
97.19
3,350
3,040
15.7
14.0
96.99
98.70
1/220/60
15.0 (530)
48 (1,695)
2.8
44
40
36
56
R22
1700
ROTARY
QP362KBB
LG
7,911(27,000)
PSC
2,571
4GSI or NM56
700
INTERNAL
Cross Flow Fan
30
Axial fan
AC Induction
63.6
30
3x2.5
3x2.5+2x0.75
9.52(3/8")
15.88(5/8")
5(196)
21.5,16 (0.85,0.63)
1090*300*180
42.9*11.8*7.09
870*655*320
34.25*25.79*12.6
12.0(26.5)
50,5(111.3)
S5+UE
21~54(69.8~129.2)
1~24(33.8~75.2)
15(49.2)
10(33)
1
Manual
Auto
Manual
Auto
-/4/3
Yes
Yes
Yes
Yes
Yes
Yes
Yes
18 - 30
16 - 30
Yes
Yes
Yes
18-30
16-30
1
Yes (24h Off)
Yes(Type3)
-

h Some of functions are slightly different depending upon models.


h The specification may be subject to change without notic for purpose of improvement.

GENERAL WALL MOUNTED

15

Specifications

SR-6RMG2-02A

Model Name (LG)


Pet Name
Cooling Capacity (T1)
Heating Capacity (H1)
Power Input Normal
Running Current
(Normal)

Cooling
Heating
Cooling
Heating

EER
COP
Power Factor

Cooling
Heating

Cooling Capacity (T3)


Power Input (T3)
Running Current (T3)
EER
Power Factor
Power Input (Max)
Running Current
(Max)
Power Factor

Cooling
Heating
Cooling
Heating
Cooling
Heating

Power Supply
Air Circulation

Indoor
Outdoor

Moisture Removal
Noise Level
(SoundPressure,1m)

Indoor
Outdoor

Refrigerant Charge

Compressor

Blower Motor
Fan Motor

Type
Model
Maker
Capacity
Motor Type
Motor Input
Oil Type
Oil Charge
O.L.P Name
Type
Output
Type
Motor Type
Motor Output

Circuit Breaker
Power Cord
Connecting Cable
Connecting Tube
(. Socket Flare)
Drain Hose
Dimension
Net Weight
Tool Code
Operation Range

Liquid Side
Gas Side
Length,std
(O.D , I.D)
Indoor
(W*H*D)
Outdoor
(W*H*D)
Indoor
Outdoor
In+Out
Cooling(Outdoor)
Heating(Outdoor)

Max. Piping Length


Max. Elevation Difference

Air flow

Air purifying
Reliability
Functions

Convenience

Individual control

GS-C2425NB2
Fresh
6,450
22,008
2,500
11.6
2.58
8.80
3
98%
5,600
19,108
3,000
13.9
1.87
6.37
98.10
3,400
16.0
96.59
1/220/60
15.0(530)
48 (1,695)
2.8
44
40
36
56
R22
900
ROTARY
QP362KBB
LG
7,911(27,000)
PSC
2,571
4GSI or NM56
700
INTERNAL
Cross Flow Fan
30
Axial fan
AC Induction
63.6
30
3x2.5
3x2.5
9.52(3/8")
15.88(5/8")
5(196)
21.5,16 (0.85,0.63)
1090*300*180
42.9*11.8*7.09
870*655*320
34.25*25.79*12.6
12.0(26.5)
42,0(92.6)
S5+UE
21~54(69.8~129.2)
15(49.2)
10(33)
1
Auto
Auto
Auto
Auto
3/4/Yes
Yes
Yes
Yes
Yes
Yes
18 - 30
Yes
Yes
Yes
Yes
Yes
18-30
1
Yes (24h On/Off)
Yes(Type2)

W
Btu/h.
W
Btu/h.
W
W
A
A
W/W
Btu/h.W
(STAR)
W/W
%
%
W
Btu/h.
W
A
W/W
Btu/h.W
%
W
W
A
A
%
%
/ V / Hz
m3/min(CFM),Max
m3/min(CFM),Max
l / h.
dB(A)+3,High
dB(A)+3,Med
dB(A)+3,Low
dB(A)+3,Max
Type
g

kcal/h.(Btu/h.)
W
cc
W
W
A
AWG#:P*mm2
AWG#:P*mm2
mm(in)
mm(in)
m(in)
mm(in)
mm
inch
mm
inch
kg(lbs)
kg(lbs)
C(F)
C(F)
m(ft)
m(ft)
Air supply outlet
Airflow direction control(left & right)
Airflow direction control(up & down)
Auto swing(left & right)
Auto swing(up & down)
Airflow steps(fan/cool/heat)
Chaos swing
Chaos wind(auto wind)
Jet cool(Power wind)
Deodorizing filter (Allergy & H1N1 Filter)
Plasma air purifier
Prefilter(Dual Protection Filter)
Hot start
Self diagnosis
Soft dry operation
Setting Temperature, Cooling
Setting Temperature, Heating
Auto changeover
Auto cleaning
Auto operation(artificial intelligence)
Auto restart operation
Forced operation
Sleep mode
Setting Temperature Range (Cooling)
Setting Temperature Range (Heating)
Temperature Increment
Timer(Hr)
Wireless remote controller(simple)
Wireless LCD remote control

Note:
O : Applied, - : No relation
* For circuit breaker rating, please conform to local standards wherever necessary.

16

GS-H2425NB2
Fresh
6,600
22,520
6,850
23,373
2,640
2,600
12.6
12.0
2.50
8.53
3
2.63
95%
98%
5,550
18,937
3,250
15.2
1.71
5.83
97.19
3,350
3,040
15.7
14.0
96.99
98.70
1/220/60
15.0 (530)
48 (1,695)
2.8
44
40
36
56
R22
1700
ROTARY
QP362KBB
LG
7,911(27,000)
PSC
2,571
4GSI or NM56
700
INTERNAL
Cross Flow Fan
30
Axial fan
AC Induction
63.6
30
3x2.5
3x2.5+2x0.75
9.52(3/8")
15.88(5/8")
5(196)
21.5,16 (0.85,0.63)
1090*300*180
42.9*11.8*7.09
870*655*320
34.25*25.79*12.6
12.0(26.5)
50,5(111.3)
S5+UE
21~54(69.8~129.2)
1~24(33.8~75.2)
15(49.2)
10(33)
1
Auto
Auto
Auto
Auto
3/4/3
Yes
Yes
Yes
Yes
Yes
Yes
Yes
18 - 30
16 - 30
Yes
Yes
Yes
Yes
Yes
18-30
16-30
1
Yes (24h On/Off)
Yes(Type2)

h Some of functions are slightly different depending upon models.


h The specification may be subject to change without notic for purpose of improvement.

GENERAL WALL MOUNTED

GENERAL WALL MOUNTED

70

Left rear
piping

105

69

Unit Outline
460

Measuring Tape
Hanger

Measuring Tape

Installation Plate

Place a level on raised tab

1030

570

56

210

Right rear
piping

325

(Unit : mm)

207

70

250

CHASSIS CODE : SC

Libero R / E

SR-6RMG2-02A
Dimensional Drawings

5. Dimensional Drawings
5.1 Indoor Unit

17

1090

GENERAL WALL MOUNTED


53.2

2-R16
50
117.6

180
300
35 180

25-5

76.6
82.6

107

48.5

50

28.5

18
53

300
50 x 6 = 300

567.5
345

178

CHASSIS CODE : S5

WALL MOUNTED

Dimensional Drawings
SR-6RMG2-02A

GENERAL WALL MOUNTED

77

71

107

28

148

50
50*6=300

567
354

912

2-R16

51
50

171
282
165

51
4

Air suction grille


Knockout hole

Note

For pipe and cable

Remark

CHASSIS CODE: SE

1. Unit should be installed in compliance with the installation manual


in the product box.
2. Unit shall be grounded in accordance with the local regulations or
applicable national codes.
3. The Unit is powered from the outdoor unit. Therefore power cable
should be connected with the outdoor unit.

Installation plate

Display & signal receiver

3
5

Front panel

Part Name

No.

ART COOL Mirror

SR-6RMG2-02A
Dimensional Drawings

19

53

282

37

20
1

Liquid Pipe Connection Port


Control Box
Earth Screw

3
4
5

Remark

GENERAL WALL MOUNTED

76, Seongsan-dong, Changwon City, Gyeongnam,


641-713, Korea
www.lge.com/airconditioner

CHASSIS CODE: UE

Unit : mm

1. The unit should be installed according to installation manual which is


in the product box.
2. In an area or a apace having no proper air circulation, an air guide
should be installed in the outdoor unit.

Note

Gas Pipe Connection Port

Part Name
Air Dicharge Grille

No.

Outdoor Unit

Dimensional Drawings
SR-6RMG2-02A

5.2 Outdoor Unit

261

450

267

275

770

770

45

56

245
285
10
65
4.3

518.4

245

55.3

2
3

CHASSIS CODE : UL

Outdoor Unit

SR-6RMG2-02A
Dimensional Drawings

GENERAL WALL MOUNTED

21

540

Wiring Diagrams

SR-6RMG2-02A

6. Wiring Diagrams
6.1 Indoor Units
Model : GS-C182C4B2, GS-C242C4B2

CN-U/D
CN-MOTOR

CN-SUB

CN-L/R

CN-DISP3

CN-HVB
CNDISP2
CN-TH1

CNOPTION

CN-12V

22

GENERAL WALL MOUNTED

SR-6RMG2-02A

Wiring Diagrams

Model : GS-H182C4B2, GS-H242C4B2

CN-U/D
CN-L/R

CN-MOTOR

CN-DISP3
CN-SUB

CN-HVB
CNDISP2
CN-TH1

CNOPTION

CN-4WAY

CN-12V

GENERAL WALL MOUNTED

23

Wiring Diagrams

SR-6RMG2-02A

TRIAC

BL(WH/Ribbed)

OR
BR(B%/Plained)

GN/YL

MAIN PWB ASM.

MOTOR

B%
CN-MOTOR

BR

YL

SH-CAPA
CN-N1
1(L) 2(N)
1(L) 2(N)

RY-COMP
GN/YL

CN-N2

FUSE
250V T2A

3
3

RY-4WAY

BR
BL
GN/YL
B%
RD

4
4

TERMINAL
BLOC%

CN-4WAY

RY-FAN

TO OUTDOOR UNIT

CN-L/R

CN-U/D

CN-DISP1 CN-DISP2 CN-12V CN-HVB

POWER

CONDUCTIVE
ENCLOSURE
MOTOR ONLY

CN-L/R CN-U/D CN-OPTION CN-TH1

Model : GS-H1825SA3, GS-H2425SA3, GS-H1825NB2, GS-H2425NB2 , GS-H122E5B2

THERMISTOR
OPTION
PWB ASM.
STEP
MOTOR
STEP
MOTOR
H.V.
ASM.
B%
B%

CN-HVB

RD AIR
B% CLEAN
(PLASMA)
B%
B%
S/W1

DISPLAY
PWB ASM.
P/No : 3854A20427B

CN-DISP2
CN-12V

CN-N2

CN-TH1
CN-N1

CN-DISP1

CN-MOTOR

CN-OPTION

24

GENERAL WALL MOUNTED

SR-6RMG2-02A

Wiring Diagrams

Model : GS-C1825SA3 GS-C2425SA3 GS-C1825NB2 GS-C2425NB2 GS-C122E5B2

CN-U/D(WH)
CN-12V(YL)

CN-L/R(BL)

CN-HVB(BL)

CN-DISP2(BL)
CN-N2
CN-N1

CN-DISP1(WH)

CN-TH1(WH)

CN-MOTOR

GENERAL WALL MOUNTED

25

Wiring Diagrams

SR-6RMG2-02A

6.2 Outdoor Unit


Model : GS-C122E5B2

Terminal Block
Capacitor

26

GENERAL WALL MOUNTED

SR-6RMG2-02A

Wiring Diagrams

Model : GS-H122E5B2

Terminal Block
Capacitor

GENERAL WALL MOUNTED

27

Wiring Diagrams

SR-6RMG2-02A

Model : GS-C1825SA3, GS-C1825NB2

Terminal Block
Capacitor

28

GENERAL WALL MOUNTED

SR-6RMG2-02A

Wiring Diagrams

Model : GS-H1825SA3, GS-H2425SA3, GS-H1825NB2, GS-H2425NB2, GS-H182C4B2, GS-H242C4B2

Terminal Block

Capacitor

GENERAL WALL MOUNTED

29

Wiring Diagrams

SR-6RMG2-02A

Model : GS-C2425SA3, GS-C2425NB2, GS-C182C4B2, GS-C242C4B2

Terminal Block

30

Capacitor

GENERAL WALL MOUNTED

SR-6RMG2-02A

Refrigerant Cycle Diagram

7. Refrigerant Cycle Diagram


Model : GS-C122*, GS-C182*, GS-C242*
INDOOR UNIT

OUTDOOR UNIT
LIQUID SIDE
CAPILLARY TUBE

HEAT
E@CHANGE:
(EVAPORATOR)

HEAT
E@CHANGE:
(CONDENSER)

GAS SIDE

COMPRESSOR

Model : GS-H122*, GS-H182*, GS-H242*


INDOOR UNIT

OUTDOOR UNIT
CHEC3 VALVE
(Heating Model only)

LIQUID SIDE
3-WAY VALVE

CAPILLARY TUBE
HEAT
E@CHANGE:
(EVAPORATOR)

HEAT
E@CHANGE:
(CONDENSER)

GAS SIDE
3-WAY VALVE

REVERSING
VALVE
(Heating Model Only)

ACCUMU%
LATOR

COOLING
HEATING

COMPRESSOR

LOC.

Description

Th1

Thermistor for indoor air temperature

Th2

Thermistor for evaporating temperature

GENERAL WALL MOUNTED

PCB Connector
CN-TH1

31

Capacity Tables

SR-6RMG2-02A

8. Capacity Tables
Cooling capacity
Model : GS-C182C4B2
Indoor Air
Temperature
CWB CDB TC
14
20 4.40
16
22 5.13
18
25 5.73
19
27 5.99
22
30 6.58
24
32 6.82

20
SHC
3.41
3.87
4.21
4.35
4.61
4.69

PI
1.30
1.32
1.34
1.37
1.38
1.40

TC
4.30
5.02
5.60
5.86
6.44
6.68

25
SHC
3.37
3.83
4.16
4.30
4.55
4.62

PI
1.55
1.57
1.59
1.62
1.64
1.66

Outdoor Air Temperature : CDB


32
35
TC SHC PI
TC SHC PI
4.10 3.28 1.80 3.98 3.21 1.90
4.79 3.72 1.83 4.64 3.64 1.93
5.34 4.03 1.86 5.18 3.94 1.96
5.59 4.16 1.89 5.42 4.07 1.99
6.13 4.40 1.91 5.95 4.29 2.02
6.37 4.46 1.94 6.17 4.35 2.04

TC
3.83
4.47
4.99
5.22
5.73
5.95

40
SHC
3.14
3.55
3.84
3.96
4.18
4.23

PI
2.02
2.05
2.08
2.12
2.14
2.17

TC
3.74
4.37
4.87
5.10
5.60
5.81

43
SHC
3.10
3.50
3.78
3.90
4.10
4.15

PI
2.09
2.12
2.15
2.19
2.21
2.25

PI
1.55
1.57
1.59
1.62
1.64
1.66

Outdoor Air Temperature : CDB


32
35
TC SHC PI
TC SHC PI
4.10 3.24 1.80 3.98 3.17 1.90
4.79 3.67 1.83 4.64 3.59 1.93
5.34 3.98 1.86 5.18 3.89 1.96
5.59 4.11 1.89 5.42 4.01 1.99
6.13 4.34 1.91 5.95 4.24 2.02
6.37 4.40 1.94 6.17 4.29 2.04

TC
3.83
4.47
4.99
5.22
5.73
5.95

40
SHC
3.10
3.50
3.79
3.91
4.12
4.17

PI
2.02
2.05
2.08
2.12
2.14
2.17

TC
3.74
4.37
4.87
5.10
5.60
5.81

43
SHC
3.06
3.45
3.73
3.85
4.05
4.10

PI
2.09
2.12
2.15
2.19
2.21
2.25

PI
2.10
2.13
2.16
2.20
2.23
2.26

Outdoor Air Temperature : CDB


32
35
TC SHC PI
TC SHC PI
5.32 4.03 2.44 5.16 3.95 2.58
6.21 4.56 2.48 6.02 4.47 2.62
6.93 4.95 2.52 6.72 4.84 2.66
7.25 5.11 2.56 7.03 4.99 2.70
7.96 5.40 2.60 7.72 5.27 2.73
8.26 5.48 2.63 8.01 5.35 2.77

TC
4.97
5.80
6.47
6.77
7.43
7.71

40
SHC
3.86
4.36
4.72
4.87
5.13
5.19

TC
4.86
5.66
6.32
6.62
7.26
7.53

43
SHC
3.81
4.29
4.64
4.79
5.04
5.10

PI
2.83
2.87
2.92
2.97
3.00
3.05

Model : GS-H182C4B2
Indoor Air
Temperature
CWB CDB TC
14
20 4.40
16
22 5.13
18
25 5.73
19
27 5.99
22
30 6.58
24
32 6.82

20
SHC
3.36
3.82
4.15
4.29
4.55
4.63

PI
1.30
1.32
1.34
1.37
1.38
1.40

TC
4.30
5.02
5.60
5.86
6.44
6.68

25
SHC
3.33
3.78
4.10
4.24
4.49
4.56

Model : GS-C242C4B2
Indoor Air
Temperature
CWB CDB TC
14
20 5.70
16
22 6.66
18
25 7.43
19
27 7.77
22
30 8.53
24
32 8.85

20
SHC
4.18
4.75
5.16
5.34
5.66
5.76

PI
1.77
1.80
1.82
1.85
1.88
1.91

TC
5.58
6.52
7.27
7.61
8.35
8.67

25
SHC
4.14
4.70
5.11
5.28
5.59
5.68

Symbol
DB : Dry bulb temperature
WB : Wet bulb temperature
TC : Total capacity
SHC : Sensible capacity
PI : Power Input
(Comp.+ indoor fan motor+outdoor fan motor)

32

PI
2.74
2.78
2.82
2.87
2.91
2.95

Notes
[C]
[C]
[kW]
[kW]
[kW]

1. All capacites are net, evaporator fan motor heat is deducted.


2.
Indicates nominal capacity.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.

GENERAL WALL MOUNTED

SR-6RMG2-02A

Capacity Tables

Model : GS-H242C4B2
Indoor Air
Temperature
CWB CDB TC
14
20 5.70
16
22 6.66
18
25 7.43
19
27 7.77
22
30 8.53
24
32 8.85

20
SHC
4.24
4.82
5.24
5.41
5.74
5.84

PI
1.87
1.90
1.93
1.96
1.98
2.01

TC
5.58
6.52
7.27
7.61
8.35
8.67

25
SHC
4.20
4.77
5.18
5.35
5.67
5.76

PI
2.21
2.25
2.28
2.32
2.35
2.38

Outdoor Air Temperature : CDB


32
35
TC SHC PI
TC SHC PI
5.32 4.09 2.58 5.16 4.00 2.72
6.21 4.63 2.62 6.02 4.53 2.76
6.93 5.02 2.66 6.72 4.91 2.80
7.25 5.18 2.71 7.03 5.06 2.85
7.96 5.48 2.74 7.72 5.35 2.89
8.26 5.56 2.78 8.01 5.42 2.93

TC
4.97
5.80
6.47
6.77
7.43
7.71

40
SHC
3.92
4.42
4.78
4.93
5.20
5.27

PI
2.89
2.94
2.98
3.03
3.07
3.11

TC
4.86
5.66
6.32
6.62
7.26
7.53

43
SHC
3.86
4.35
4.71
4.85
5.11
5.17

PI
2.99
3.03
3.08
3.13
3.17
3.22

Model : GS-C122E5B2
Indoor Air
Temperature
CWB CDB
14
20
16
22
18
25
19
27
22
30
24
32

20.0
TC
2.86
3.33
3.72
3.89
4.27
4.43

PI
0.79
0.80
0.81
0.82
0.83
0.85

25.0
TC
2.79
3.26
3.64
3.81
4.18
4.34

PI
0.93
0.95
0.96
0.98
0.99
1.00

PI
1.09
1.10
1.12
1.14
1.15
1.17

Outdoor Air Temperature : CDB


35.0
40.0
TC
PI
TC
PI
2.58 1.14 2.49 1.22
3.01 1.16 2.90 1.24
3.36 1.18 3.24 1.26
3.52 1.20 3.39 1.28
3.86 1.22 3.72 1.29
4.01 1.23 3.86 1.31

43.0
TC
PI
2.41 1.26
2.81 1.28
3.13 1.30
3.28 1.32
3.60 1.34
3.73 1.35

46.1
TC
PI
2.29 1.34
2.66 1.36
2.98 1.37
3.11 1.40
3.41 1.42
3.54 1.44

57.1
TC
PI
2.12 1.37
2.46 1.38
2.77 1.40
2.88 1.43
3.17 1.45
3.28 1.47

PI
1.09
1.10
1.12
1.14
1.15
1.17

Outdoor Air Temperature : CDB


35.0
40.0
TC
PI
TC
PI
2.47 1.14 2.38 1.22
2.89 1.16 2.78 1.24
3.22 1.18 3.10 1.26
3.37 1.20 3.25 1.28
3.70 1.22 3.56 1.29
3.84 1.23 3.70 1.31

43.0
TC
PI
2.30 1.26
2.69 1.28
3.00 1.30
3.14 1.32
3.45 1.34
3.58 1.35

46.1
TC
PI
2.20 1.34
2.56 1.36
2.87 1.37
2.99 1.40
3.28 1.42
3.40 1.44

57.1
TC
PI
2.04 1.37
2.37 1.38
2.66 1.40
2.77 1.43
3.05 1.45
3.16 1.47

32.0
TC
2.66
3.11
3.47
3.63
3.98
4.13

Model : GS-H122E5B2
Indoor Air
Temperature
CWB CDB
14
20
16
22
18
25
19
27
22
30
24
32

20.0
TC
2.73
3.19
3.56
3.73
4.09
4.24

PI
0.79
0.80
0.81
0.82
0.83
0.85

25.0
TC
2.68
3.12
3.49
3.65
4.00
4.15

PI
0.93
0.95
0.96
0.98
0.99
1.00

32.0
TC
2.55
2.98
3.32
3.48
3.81
3.96

Symbol
DB : Dry bulb temperature
WB : Wet bulb temperature
TC : Total capacity
SHC : Sensible capacity
PI : Power Input
(Comp.+ indoor fan motor+outdoor fan motor)

Notes
[C]
[C]
[kW]
[kW]
[kW]

1. All capacites are net, evaporator fan motor heat is deducted.


2.
Indicates nominal capacity.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.

GENERAL WALL MOUNTED

33

SR-6RMG2-02A

Model : GS-C1825SA3, GS-C1825NB2


Indoor Air
Temperature
CWB CDB
14
20
16
22
18
25
19
27
22
30
24
32

20.0
TC
4.16
4.85
5.42
5.67
6.22
6.46

PI
1.31
1.33
1.35
1.37
1.39
1.41

25.0
TC
4.07
4.75
5.30
5.55
6.09
6.32

PI
1.55
1.58
1.60
1.63
1.65
1.67

PI
1.81
1.84
1.87
1.90
1.92
1.95

Outdoor Air Temperature : CDB


35.0
40.0
TC
PI
TC
PI
3.76 1.91 3.62 2.03
4.39 1.94 4.23 2.06
4.90 1.97 4.72 2.09
5.13 2.00 4.94 2.13
5.63 2.03 5.42 2.15
5.84 2.06 5.63 2.19

43.0
TC
PI
3.51 2.10
4.09 2.13
4.56 2.16
4.78 2.20
5.24 2.23
5.44 2.26

46.1
TC
PI
3.30 2.20
3.83 2.23
4.31 2.26
4.48 2.30
4.93 2.33
5.10 2.36

57.1
TC
PI
3.06 2.24
3.56 2.27
4.00 2.31
4.16 2.35
4.57 2.38
4.73 2.41

PI
1.90
1.93
1.96
1.99
2.02
2.05

Outdoor Air Temperature : CDB


35.0
40.0
TC
PI
TC
PI
3.66 2.00 3.53 2.13
4.27 2.03 4.11 2.16
4.77 2.07 4.59 2.20
4.99 2.10 4.80 2.23
5.48 2.13 5.27 2.26
5.68 2.16 5.47 2.30

43.0
TC
PI
3.41 2.20
3.98 2.23
4.44 2.27
4.65 2.31
5.10 2.34
5.29 2.37

46.1
TC
PI
3.15 2.34
3.66 2.37
4.11 2.41
4.28 2.45
4.70 2.48
4.87 2.52

57.1
TC
PI
2.92 2.39
3.39 2.42
3.81 2.46
3.97 2.50
4.36 2.54
4.52 2.57

43.0

46.1

57.1

PI
1.86
1.88
1.91
1.95
1.97
2.00

Outdoor Air Temperature : CDB


35.0
40.0
TC
PI
TC
PI
3.76 1.96 3.62 2.08
4.39 1.99 4.23 2.11
4.90 2.02 4.72 2.14
5.13 2.05 4.94 2.18
5.63 2.08 5.42 2.21
5.84 2.11 5.63 2.24

32.0
TC
3.88
4.53
5.05
5.29
5.80
6.02

Model : GS-H1825SA3
Indoor Air
Temperature
CWB CDB
14
20
16
22
18
25
19
27
22
30
24
32

20.0
TC
4.05
4.72
5.27
5.51
6.05
6.28

PI
1.38
1.40
1.42
1.44
1.46
1.48

25.0
TC
3.96
4.62
5.16
5.40
5.92
6.15

PI
1.63
1.66
1.68
1.71
1.73
1.76

32.0
TC
3.78
4.40
4.91
5.14
5.64
5.86

Model : GS-H1825NB2
Indoor Air
Temperature
CWB CDB
14
20
16
22
18
25
19
27
22
30
24
32

20.0
TC
4.16
4.85
5.42
5.67
6.22
6.46

PI
1.34
1.36
1.38
1.41
1.43
1.45

25.0
TC
4.07
4.75
5.30
5.55
6.09
6.32

PI
1.59
1.62
1.64
1.67
1.69
1.71

32.0
TC
3.88
4.53
5.05
5.29
5.80
6.02

Symbol
DB : Dry bulb temperature
WB : Wet bulb temperature
TC : Total capacity
SHC : Sensible capacity
PI : Power Input
(Comp.+ indoor fan motor+outdoor fan motor)

34

TC
3.51
4.09
4.56
4.78
5.24
5.44

PI
2.15
2.18
2.21
2.25
2.28
2.31

TC
3.26
3.78
4.25
4.43
4.86
5.04

PI
2.34
2.37
2.41
2.45
2.48
2.52

TC
3.02
3.51
3.94
4.10
4.51
4.67

PI
2.39
2.42
2.46
2.50
2.54
2.57

Notes
[C]
[C]
[kW]
[kW]
[kW]

1. All capacites are net, evaporator fan motor heat is deducted.


2.
Indicates nominal capacity.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.

GENERAL WALL MOUNTED

SR-6RMG2-02A

Model : GS-C2425SA3, GS-C2425NB2


Indoor Air
Temperature
CWB CDB
14
20
16
22
18
25
19
27
22
30
24
32

20.0
TC
5.23
6.10
6.81
7.13
7.82
8.12

PI
1.64
1.66
1.69
1.72
1.74
1.76

25.0
TC
5.12
5.97
6.67
6.98
7.66
7.95

PI
1.94
1.97
2.00
2.04
2.06
2.09

PI
2.26
2.30
2.33
2.37
2.40
2.44

Outdoor Air Temperature : CDB


35.0
40.0
TC
PI
TC
PI
4.73 2.38 4.56 2.54
5.52 2.42 5.32 2.58
6.16 2.46 5.93 2.61
6.45 2.50 6.21 2.66
7.08 2.53 6.82 2.69
7.35 2.57 7.07 2.73

43.0
TC
PI
4.41 2.62
5.14 2.66
5.74 2.70
6.01 2.75
6.59 2.78
6.84 2.82

46.1
TC
PI
4.12 2.86
4.79 2.91
5.38 2.95
5.60 3.00
6.15 3.04
6.37 3.08

57.1
TC
PI
3.83 2.93
4.44 2.97
4.99 3.01
5.19 3.06
5.70 3.11
5.91 3.15

PI
2.44
2.48
2.52
2.56
2.60
2.63

Outdoor Air Temperature : CDB


35.0
40.0
TC
PI
TC
PI
4.62 2.58 4.45 2.74
5.39 2.62 5.19 2.78
6.02 2.66 5.80 2.82
6.30 2.70 6.07 2.87
6.91 2.73 6.66 2.91
7.17 2.77 6.91 2.95

43.0
TC
PI
4.31 2.83
5.02 2.87
5.61 2.92
5.87 2.97
6.44 3.00
6.68 3.05

46.1
TC
PI
3.97 3.10
4.61 3.15
5.18 3.19
5.39 3.25
5.92 3.29
6.14 3.34

57.1
TC
PI
3.69 3.17
4.28 3.21
4.80 3.26
5.00 3.32
5.50 3.36
5.69 3.41

43.0

46.1

57.1

PI
2.39
2.43
2.46
2.51
2.54
2.58

Outdoor Air Temperature : CDB


35.0
40.0
TC
PI
TC
PI
4.84 2.52 4.66 2.68
5.65 2.56 5.44 2.72
6.31 2.60 6.07 2.76
6.60 2.64 6.35 2.81
7.24 2.67 6.97 2.84
7.52 2.71 7.24 2.89

32.0
TC
4.88
5.69
6.35
6.65
7.30
7.57

Model : GS-H2425SA3
Indoor Air
Temperature
CWB CDB
14
20
16
22
18
25
19
27
22
30
24
32

20.0
TC
5.11
5.96
6.65
6.96
7.64
7.93

PI
1.77
1.80
1.82
1.85
1.88
1.91

25.0
TC
5.00
5.84
6.51
6.81
7.48
7.76

PI
2.10
2.13
2.16
2.20
2.23
2.26

32.0
TC
4.77
5.56
6.20
6.49
7.13
7.40

Model : GS-H2425NB2
Indoor Air
Temperature
CWB CDB
14
20
16
22
18
25
19
27
22
30
24
32

20.0
TC
5.35
6.25
6.97
7.29
8.00
8.31

PI
1.73
1.76
1.78
1.81
1.84
1.86

25.0
TC
5.24
6.11
6.82
7.14
7.83
8.13

PI
2.05
2.08
2.11
2.15
2.18
2.21

32.0
TC
4.99
5.83
6.50
6.80
7.47
7.75

Symbol
DB : Dry bulb temperature
WB : Wet bulb temperature
TC : Total capacity
SHC : Sensible capacity
PI : Power Input
(Comp.+ indoor fan motor+outdoor fan motor)

TC
4.51
5.26
5.87
6.15
6.75
7.00

PI
2.77
2.81
2.85
2.90
2.94
2.98

TC
4.08
4.74
5.32
5.54
6.09
6.30

PI
3.08
3.13
3.17
3.23
3.27
3.32

TC
3.79
4.39
4.94
5.14
5.65
5.85

PI
3.15
3.19
3.24
3.30
3.34
3.39

Notes
[C]
[C]
[kW]
[kW]
[kW]

1. All capacites are net, evaporator fan motor heat is deducted.


2.
Indicates nominal capacity.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.

GENERAL WALL MOUNTED

35

SR-6RMG2-02A

Heating capacity
Model : GS-H182C4B2
Indoor Air
Temperature

-10

-5

Outdoor Air Temperature : CWB


2
4
6
TC
PI
TC
PI
TC
PI

10

15

CDB

TC

PI

TC

PI

TC

PI

TC

PI

TC

PI

16

3.86

1.34

4.55

1.47

5.26

1.60

5.52

1.65

5.79

1.70

6.12

1.72

6.62

1.82

7.31

1.94

18

3.74

1.39

4.40

1.52

5.09

1.65

5.35

1.70

5.60

1.75

5.92

1.78

6.41

1.88

7.08

2.01

20

3.63

1.43

4.27

1.57

4.94

1.71

5.19

1.76

5.44

1.81

5.71

1.84

6.22

1.94

6.86

2.08

22

3.49

1.48

4.12

1.62

4.76

1.76

5.00

1.81

5.24

1.87

5.54

1.90

5.99

2.00

6.62

2.14

24

3.37

1.52

3.98

1.67

4.60

1.81

4.83

1.87

5.06

1.93

5.35

1.96

5.79

2.06

6.39

2.21

TC

PI

TC

PI

Model : GS-H242C4B2
Indoor Air
Temperature

-10

-5

Outdoor Air Temperature : CWB


2
4
6
TC
PI
TC
PI
TC
PI

10

15

CDB

TC

PI

TC

PI

TC

PI

16

5.14

2.02

6.06

2.21

7.01

2.40

7.36

2.48

7.72

2.55

8.15

2.60

8.83

2.73

9.74

2.93

18

4.98

2.09

5.87

2.28

6.79

2.49

7.13

2.56

7.47

2.64

7.90

2.68

8.55

2.83

9.43

3.03

20

4.83

2.16

5.69

2.36

6.59

2.57

6.92

2.65

7.25

2.73

7.62

2.77

8.29

2.92

9.15

3.13

22

4.66

2.23

5.49

2.43

6.35

2.65

6.67

2.73

6.99

2.81

7.38

2.86

7.99

3.01

8.82

3.23

24

4.50

2.29

5.30

2.51

6.13

2.73

6.44

2.81

6.75

2.90

7.13

2.95

7.72

3.10

8.52

3.32

Outdoor Air Temperature : CWB


2
4
6
TC
PI
TC
PI
TC
PI

TC

PI

TC

PI

Model : GS-H122E5B2
Indoor Air
Temperature

-10

-5

15

TC

PI

TC

PI

TC

PI

16

2.38

0.84

2.80

0.92

3.24

1.00

3.40

1.03

3.56

1.06

3.77

1.08

4.08

1.13

4.50

1.22

18

2.30

0.87

2.71

0.95

3.14

1.03

3.29

1.06

3.45

1.10

3.65

1.11

3.95

1.17

4.36

1.26

20

2.23

0.90

2.63

0.98

3.04

1.07

3.20

1.10

3.35

1.13

3.52

1.15

3.83

1.21

4.23

1.30

22

2.15

0.92

2.54

1.01

2.93

1.10

3.08

1.13

3.23

1.17

3.41

1.19

3.69

1.25

4.08

1.34

24

2.08

0.95

2.45

1.04

2.83

1.13

2.98

1.17

3.12

1.20

3.29

1.22

3.57

1.29

3.94

1.38

Symbol
DB : Dry bulb temperature
WB : Wet bulb temperature
TC : Total capacity
SHC : Sensible capacity
PI : Power Input
(Comp.+ indoor fan motor+outdoor fan motor)

36

10

CDB

Notes
[C]
[C]
[kW]
[kW]
[kW]

1. All capacites are net, evaporator fan motor heat is deducted.


2.
Indicates nominal capacity.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.

GENERAL WALL MOUNTED

SR-6RMG2-02A

Model : GS-H1825SA3
Indoor Air
Temperature

-10

-5

Outdoor Air Temperature : CWB


2
4
6
TC
PI
TC
PI
TC
PI

CDB

TC

PI

TC

PI

TC

PI

16

3.44

1.28

4.05

1.39

4.69

1.52

4.93

1.57

5.16

1.61

5.45

18

3.33

1.32

3.93

1.44

4.54

1.57

4.77

1.62

5.00

1.67

5.28

20

3.23

1.36

3.81

1.49

4.41

1.62

4.63

1.67

4.85

1.72

22

3.12

1.41

3.67

1.54

4.25

1.67

4.46

1.72

4.67

1.78

24

3.01

1.45

3.55

1.58

4.10

1.73

4.31

1.78

4.51

1.83

10

15

TC

PI

TC

PI

1.64

5.90

1.73

6.52

1.85

1.70

5.72

1.79

6.31

1.91

5.09

1.75

5.55

1.84

6.12

1.97

4.94

1.81

5.35

1.90

5.90

2.04

4.77

1.86

5.16

1.96

5.70

2.10

TC

PI

TC

PI

Model : GS-H1825NB2
Indoor Air
Temperature

-10

-5

Outdoor Air Temperature : CWB


2
4
6
TC
PI
TC
PI
TC
PI

10

15

CDB

TC

PI

TC

PI

TC

PI

16

3.54

1.28

4.18

1.39

4.83

1.52

5.07

1.57

5.32

1.61

5.62

1.64

6.08

1.73

6.71

1.85

18

3.43

1.32

4.04

1.44

4.68

1.57

4.91

1.62

5.15

1.67

5.44

1.70

5.89

1.79

6.50

1.91

20

3.33

1.36

3.92

1.49

4.54

1.62

4.77

1.67

5.00

1.72

5.25

1.75

5.71

1.84

6.31

1.97

22

3.21

1.41

3.78

1.54

4.38

1.67

4.59

1.72

4.81

1.78

5.09

1.81

5.51

1.90

6.08

2.04

24

3.10

1.45

3.65

1.58

4.22

1.73

4.44

1.78

4.65

1.83

4.91

1.86

5.32

1.96

5.87

2.10

Model : GS-H2425SA3
Indoor Air
Temperature

-10

-5

Outdoor Air Temperature : CWB


2
4
6
TC
PI
TC
PI
TC
PI

10

15

CDB

TC

PI

TC

PI

TC

PI

TC

PI

TC

PI

16

4.49

1.90

5.29

2.07

6.12

2.26

6.43

2.33

6.73

2.40

7.12

2.44

7.70

2.57

8.50

2.75

18

4.35

1.96

5.12

2.14

5.93

2.33

6.22

2.40

6.52

2.48

6.89

2.52

7.46

2.65

8.23

2.84

20

4.22

2.02

4.97

2.21

5.75

2.41

6.04

2.48

6.33

2.56

6.65

2.60

7.24

2.74

7.99

2.93

22

4.07

2.09

4.79

2.28

5.54

2.49

5.82

2.56

6.10

2.64

6.44

2.68

6.98

2.83

7.70

3.03

24

3.93

2.15

4.63

2.35

5.35

2.56

5.62

2.64

5.89

2.72

6.22

2.77

6.74

2.91

7.44

3.12

Symbol
DB : Dry bulb temperature
WB : Wet bulb temperature
TC : Total capacity
SHC : Sensible capacity
PI : Power Input
(Comp.+ indoor fan motor+outdoor fan motor)

Notes
[C]
[C]
[kW]
[kW]
[kW]

1. All capacites are net, evaporator fan motor heat is deducted.


2.
Indicates nominal capacity.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.

GENERAL WALL MOUNTED

37

Capacity Tables

SR-6RMG2-02A

Model : GS-H2425NB2
Indoor Air
Temperature

-10

-5

Outdoor Air Temperature : CWB


2
4
6
TC
PI
TC
PI
TC
PI

CDB

TC

PI

TC

PI

TC

PI

16

4.63

1.90

5.45

2.07

6.30

2.26

6.62

2.33

6.94

2.40

7.33

18

4.48

1.96

5.28

2.14

6.10

2.33

6.41

2.40

6.72

2.48

7.10

20

4.35

2.02

5.12

2.21

5.92

2.41

6.22

2.48

6.52

2.56

22

4.19

2.09

4.93

2.28

5.71

2.49

6.00

2.56

6.28

2.64

24

4.04

2.15

4.76

2.35

5.51

2.56

5.79

2.64

6.07

2.72

Symbol
DB : Dry bulb temperature
WB : Wet bulb temperature
TC : Total capacity
SHC : Sensible capacity
PI : Power Input
(Comp.+ indoor fan motor+outdoor fan motor)

38

10

15

TC

PI

TC

PI

2.44

7.93

2.57

8.76

2.75

2.52

7.68

2.65

8.48

2.84

6.85

2.60

7.45

2.74

8.23

2.93

6.64

2.68

7.19

2.83

7.93

3.03

6.41

2.77

6.94

2.91

7.66

3.12

Notes
[C]
[C]
[kW]
[kW]
[kW]

1. All capacites are net, evaporator fan motor heat is deducted.


2.
Indicates nominal capacity.
3. Direct interpolation is permissible. Do not extrapolate
4. Capacities are based on the following conditions:
- Interconnecting Piping Length 7.5m
- Level Difference of Zero.

GENERAL WALL MOUNTED

SR-6RMG2-02A

Capacity Coefficient Factor

9. Capacity Coefficient Factor


Model: 9 kBtu/h ~ 26 kBtu/h Cooling Only

Classification

Capacity Coefficient factor


Total Pipe Length(m)

Height
(A)

Outdoor

7.5

10

12.5

15

10

(0.94)

(0.93)

0.97

0.96

(0.95)

(0.94)

0.99

0.98

0.97

(0.96)

(0.95)

1.0

0.99

0.98

(0.97)

(0.96)

1.0

0.99

0.98

(0.97)

(0.96)

0.99

0.98

0.97

(0.96)

(0.95)

0.97

0.96

(0.95)

(0.94)

10

(0.94)

(0.93)

(A)
Indoor
Indoor
(A)
Outdoor

The values in parentheses are valid only for 18~24kBtu models.

Model: 5 kBtu/h ~ 14 kBtu/h Heat Pump


Classification

Capacity Coefficient factor


Total Pipe Length(m)

Height
(A)

Outdoor
(A)
Indoor
Indoor
(A)
Outdoor

7.5

10

12.5

15

10

0.97

0.97

0.99

0.98

0.97

1.0

0.99

0.98

1.0

0.99

0.98

0.99

0.98

0.97

0.97

0.97

10

GENERAL WALL MOUNTED

39

Operation Range
Capacity
kW (kBtu/h)

SR-6RMG2-02A
Pipe Size[mm(in)]
GAS
LIQUID

Standard
Length m(ft)

Max.
Elevation m(ft)

Max.
Length m(ft)

Additional Refrigerant
g/m(oz/ft)

3.5(12)

12.7(1/2)

6.35(1/4)

5(16)

10(33)

15(49)

20(0.22)

5.3(18)

15.88(5/8)

6.35(1/4)

5(16)

10(33)

15(49)

20(0.22)

7.0(24)

15.88(5/8)

9.52(3/8)

5(16)

10(33)

15(49)

30(0.32)

Indoor unit
Outdoor unit

A
B

A
Outdoor unit

Indoor unit

CAUTION
Capacity is based on standard length and maximum allowable length is on the basis of reliability.
Additional refrigerant must be charged after 5m.

40

GENERAL WALL MOUNTED

SR-6RMG2-02A

Air Velocity and Temperature Distribution(Reference Data)

10. Air Velocity and Temperature Distribution(Reference Data)


General Wall Mounted 18/24 kBtu/h
Model : GS-C182C4B2, GS-H182C4B2, GS-C1825*,GS-C2425*, GS-H1825*,GS-H2425*
Cooling

Heating

Discharge angle:45

Discharge angle:50
Air velocity [m/s]

Air velocity [m/s]

1.5

8m

7m

6m

5m

4m

0.5
3m

2.7m

2.7m

2m

2m
1.5

1m

1.25
0.75 1.0
2m

1m

0.5
8m

0m

23

7m

6m

6m

5m

4m

3m

0.75
2m

1m

0m

Temperature [C]

Temperature [C]

8m

7m

1m

1.25
1.0

5m

25
4m

2.7m

2.7m

2m

2m
31

1m

2m

29

28

24
3m

1m

0m

8m

GENERAL WALL MOUNTED

7m

6m

5m

4m

3m

2m

1m

30
1m

0m

41

Controller

SR-6RMG2-02A

11. Controller
Type 1 (Wireless LCD)

Control panel Display screen

Display
screen

JET
COOL

C/F[5SEC]

Control
panel

Plasma button*: Purifies the air by removing


particles that enter the indoor unit.

Air circulation button*: Used to circulate the


room air without cooling or heating.

Sleep mode auto button*: Sets the sleep mode


auto operation.

Temperature adjustment buttons: Adjusts the


room temperature when cooling and heating.

d
g
f

Display
screen

JET
COOL

C/F[5SEC]

Control
panel

Description

7 v

Indoor fan speed button: Adjusts the fan


speed.

Operation mode selection button*: Selects the


operation mode.
A C
Cooling operation (A) / Auto operation or auto
D B E changeover (C) / Dehumidifying operation (D) /
Heating operation (B) / Air circulation (E)

JET
COOL

On/Off button: Turns the power on/off.

Jet cooling/heating button*: Warms up or cools


down the indoor temperature within a short period of time.
Air flow direction button: Adjusts the air flow
direction vertically or horizontally.

i j

H I

Temperature display button: Displays the room


temperature.

m n

Timer button: Sets the current time and the start


/ end time.

J G P

Functions button*: Adjusts the time and sets


the special functions.
J: Auto clean / G: Operates energy saving cooling / P: Adjusts the brightness of the indoor unit
display

c
b

Set/clear button: Sets or cancels functions.

Reset button: Initialize the air conditioner settings.

* Some functions may not be supported, depending on the model.

42

GENERAL WALL MOUNTED

SR-6RMG2-02A

Type 2 (Wireless LCD)

Signal transmitter

6
3
4
10

2
7
11
8
13

CANCEL
ON

OFF

9
12
17
19
18
14

SET
AUTO CLEAN

15

16

Flip-up door
(opened)

Operation Mode
Cooling Operation
Auto Operation or Auto Changeover

Healthy Dehumidification Operation

Heating Operation

Cooling Model(

NOTE

), Heat Pump Model(

1. START/STOP BUTTON
Used to turn off/on the unit.
2. OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
3. ROOM TEMPERATURE SETTING BUTTONS
Used to select the room temperature.
4. INDOOR FAN SPEED SELECTOR BUTTON
Used to select fan speed in four steps
low, medium, high and CHAOS.
5. JET COOL BUTTON
Used to start or stop the speed cooling.
(It operates fan in super high speed in cooling mode)
6. CHAOS SWING BUTTON
Used to stop or start louver movement and set the
desired up/down airflow direction.
7. ON/OFF TIMER BUTTONS
Used to set the time of starting and stopping
operation.
8. TIME SETTING BUTTONS
Used to adjust the time.
9. TIMER SET/CANCEL BUTTON
Used to set and to cancel the timer operation.
10. SLEEP MODE AUTO BUTTON
Used to set sleep mode auto operation.
11. AIR CIRCULATION BUTTON
Used to circulate the room air without cooling or
heating.
ENERGY-SAVING COOLING MODE BUTTON
(OPTIONAL) For inverter type models
12. ROOM TEMPERATURE CHECKING BUTTON
Used to check the room temperature.
13. PLASMA BUTTON(OPTIONAL)
Used to start or stop the plasma-purification
function.
14. HORIZONTAL AIRFLOW DIRECTION CONTROL
BUTTON (OPTIONAL)
Used to set the desired horizontal airflow direction.
15. RESET BUTTON
Used prior to resetting time.
16. 2nd F BUTTON
Used prior to using modes printed in blue at the
bottom of buttons.
17. AUTO CLEAN BUTTON(OPTIONAL)
Used to set auto clean mode.
In some models this button has a 2nd function of LED
luminosity control.
18. HEATER BUTTON(OPTIONAL)
(Not available in all models)
19. LCD LUMINOSITY BUTTON(OPTIONAL)
Used to adjust LCD luminosity.

To use the functions printed in blue at the bottom of the buttons press 2nd F button first and then the required function
button. Pressing the 2nd F button activates the blue printed function of the respective button. To cancel the function
press the 2nd F button again else it will automatically cancel if remains idle after 10 seconds.

GENERAL WALL MOUNTED

43

SR-6RMG2-02A

Type 3 (Wireless Simple)

5
6

1. OPERATION DISPLAY
Displays the operation conditions.
2. CHAOS SWING BUTTON
Used to stop or start louver movement and set
the desired up/down airflow direction
3. OPERATION MODE SELECTION BUTTON
Used to select the operation mode.
4. OFF TIMER BUTTON
Used to set the time of stopping opertion.
5. START/STOP BUTTON
Operation starts when this button is pressed, and
stops when the button is pressed again.
6. ROOM TEMPERATURE SETTING BUTTONS
7. INDOOR FAN SPEED SELECTION BUTTON
Used to set the time of starting and stopping
operation.
8. JET COOL
Used to start or stop the speed cooling (Speed
cooling operates super high fan speed ing
cooling mode.)

(1) Operation Mode

(2) Operation Procedure

1
3

44

GENERAL WALL MOUNTED

SR-6RMG2-02A

Installation

12. Installation
12.1 Installation Map

Installation plate
Sleeve
Bushing-Sleeve
Putty(Gum Type Sealant)
Bend the pipe as closely
on the wall as possible,
but be careful that it
doesn't break.

Saddle

Vinyl tape (Wide)


Apply after carrying out a
drainage test.
To carry out the drainage
test, remove the air filters
and pour water into the heat
exchanger.

Gas side piping

Air Inlet

Liquid side piping


Additional drain pipe

Air Outlet

Vinyl tape (Narrow)


Drain Hose
Connecting cable
Base Plate

Tubing Cover

* The feature can be changed according to the type of model.

NOTE
() You should purchase the installation parts.

GENERAL WALL MOUNTED

45

Installation

SR-6RMG2-02A

12.2 Select the best Location


Indoor unit
1. There should not be any heat or steam near the unit.
2. Select a place where there are no obstacles around the
unit.

More than
100

More than 200

3. Make sure that condensation drainage can be conveniently


routed away.
5. Ensure that the gap between a wall and the left (or right) of
the unit is more than 100mm. The unit should be installed
as high as possible on the wall, allowing a minimum of
200mm from ceiling.

More than
100
More than 2300
(Unit : mm)

6. Use a metal detector to locate studs to prevent unnecessary damage to the wall.

* The feature can be changed according to the type of


model.

CAUTION
Install the indoor unit on the wall where the height from the floor is more than 2300mm.

Outdoor unit
1. If an awning is built over the unit to prevent direct sunlight
or rain exposure, make sure that heat radiation from the
condenser is not restricted.
2. Ensure that the space around the back side and other
sides is more than 300mm. The space in front of the unit
should be more than 700mm.
3. Do not place animals and plants in the path of the warm
air.
4. Take the weight of the air conditioner into account and
select a place where noise and vibration are minimum.
5. Select a place where the warm air and noise from the air
conditioner do not disturb neighbors.

46

GENERAL WALL MOUNTED

More than
300

Fe
ob nce o
sta r
cle
s

Su
nro
of

More than
300

More than
600
More than
700

(Unit : mm)

SR-6RMG2-02A

Installation

12.3 Fixing Installation Plate


The wall you select should be strong and solid enough to prevent
vibration
1. Mount the installation plate on the wall with type "A" screws. If
mounting the unit on a concrete wall, use anchor bolts.

Installation Plate

Mount the installation plate horizontally by aligning the centerline using Horizontal meter .
Type "A" Screws

Chassis
Hook

2. Measure the wall and mark the centerline. It is also important to


use caution concerning the location of the installation plate.
Routing of the wiring to power outlets is through the walls typically. Drilling the hole through the wall for piping connections must be
done safely.

Place a level on raised tab

Unit Outline

460

65
Left
rear
piping

570

65

Installation Plate
Measuring Tape

105

Right
rear
piping

56

69

207

Measuring Tape
Hanger

(Unit : mm)

12.4 Drill a Hole in the Wall


WALL

Bushing
Sleeve

Outdoor

5-7mm

Indoor

(3/16"~5/16")

Drill the piping hole with a 65mm hole core drill. Drill the
piping hole at either the right or the left with the hole
slightly slanted to the outdoor side.

CAUTION
Use the sleeve to prevent damage for tube assembly.

GENERAL WALL MOUNTED

47

Installation

SR-6RMG2-02A

12.5 Flaring Work


Main cause for gas leakage is due to defect of flaring work. Carry out correct flaring work in the following procedure.

Cut the pipes and the cable.


1. Use the piping kit accessory or the pipes purchased locally.
2. Measure the distance between the indoor and the outdoor unit.
3. Cut the pipes a little longer than measured distance.
4. Cut the cable 1.5m longer than the pipe length.

Copper
pipe

90

Slanted Uneven Rough

Burrs removal
1. Completely remove all burrs from the cut cross section of pipe/tube.

Pipe

2. While removing the burrs, hold the end of the pipe in downward direction in order to avoid dropping burrs into the tubing.

Reamer

Point down

Putting nut on
- Remove flare nuts attached to indoor and outdoor units, then put them
on the pipe/tube which have completed its burr removal.
(not possible to put them on after finishing flare work)

Flare nut

Copper tube

Flaring work
1. Firmly hold copper pipe in a bar with the dimension shown in
table below.
2. Carry out flaring work with the flaring tool.
"A"

Bar

Handle
Bar
Yoke

Outside diameter

48

Thickness

mm

inch

mm

mm

6.35

1/4"

1.1~1.3

0.7

9.52

3/8"

1.5~1.7

0.8

12.7

1/2"

1.6~1.8

0.8

15.88

5/8"

1.6~1.8

1.0

19.05

3/4"

1.9~2.1

1.0

GENERAL WALL MOUNTED

Cone
Copper pipe
Clamp handle

Red arrow mark

SR-6RMG2-02A

Installation

Check
1. Compare the flared work with the figures given below.
2. If a flared section is defective, cut it off and do flaring work
again.

Smooth all round


Inside is shiny without scratches
= Improper flaring =

Even length
all round

Inclined Surface Cracked Uneven


damaged
thickness

12.6 Connecting the pipes


1. Pull the screw caps at the bottom of the indoor unit
2. Remove the chassis cover from the unit by loosing 3 screws

Chassis cover

3. Pull back the tubing holder.


4. Remove the pipe port cover and position the piping.
Back side view

*The feature can be changed according to the type of model.

Pipe Port
Left
Right

Tubing holder
Backwards

GENERAL WALL MOUNTED

49

Installation

SR-6RMG2-02A

Good case
Press the tubing cover and slowly unfold the tubing to downward. And then bend to the left side slowly.

Bad case
Following bending case from right to left directly may cause damage to the tubing.

* The feature can be changed according to the type of model.

CAUTION
Installation Information. For right piping. Follow the instruction above.

50

GENERAL WALL MOUNTED

SR-6RMG2-02A

Installation

12.7 Installation of Indoor Unit


1. Hook the indoor unit onto the upper portion of the installation plate.( engage the three hooks at the top of the indoor unit with
the upper edge of the installation plate) Ensure that the hooks are properly seated on the installation plate by moving it left
and right

Installation plate

2. Unlock the tubing holder from the chassis and mount between the chassis and installation plate in order to separate the bottom side of the indoor unit from the wall.

Tubing Holder

*The feature can be changed according to the type of model.

GENERAL WALL MOUNTED

51

Installation

SR-6RMG2-02A

3. Insert the connecting cable through the bottom side of


indoor unit and connect the cable

Control Cover

Open the Front Grille


Support the Front Grille with supporter
Open the Control Cover
Connect the connecting cable

Case 1

Case 2

Case 3

4. Tape the tubing pipe, drain hose and the connection cable. Be sure that the drain hose is located at the lowest side of the
bundle. Locating at the upper side can cause overflow from the drain pan through the inside of the unit.
<Left side piping>

<Right side piping>

Tape
Connecting
cable
Drain hose
Connecting pipe
Drain hose

Tape
Connecting
cable
Drain hose
Connecting pipe

*The feature can be changed according to the type of model.

CAUTION

Indoor

If the extension drain hose is routed inside the room,


insulate the hose with an insulation material* so that dripping from sweating (condensation) could not damage furniture or floors.

Insulation
Indoor Unit (More than 100~300mm
Drain hose length and 7mm thickness)
Extension
drain hose

Foamed polyethylene or equivalent is recommended.


Indoor Unit
Drain hose

52

Outdoor

GENERAL WALL MOUNTED

SR-6RMG2-02A

Installation

Connecting the installation pipe and drain


hose to the indoor unit.
1. Align the center of the pipes and sufficiently tighten the
flare nut by hand

Indoor unit tubing

Flare nut

Pipes

2. Tighten the flare nut with a wrench


Outside Diameter
mm
inch
6.35
1/4
9.52
3/8
12.7
1/2
15.88
5/8
19.05
3/4

Open-end wrench (fixed)

Torque
kgfcm
Nm
180~250
17.6~24.5
340~420
33.3~41.2
550~660
53.9~64.7
630~820
61.7~80.4
990~1210
97~118.6

Flare nut
Wrench

Connection pipe

Indoor unit tubing

Drain pipe

3. When needed to extend the drain hose of indoor unit,


assembly the drain pipe as shown on the drawing

Indoor unit drain hose


Adhesive Vinyl tape(narrow)

Wrap the insulation material around the connecting portion.

Insulation material

1. Overlap the connection pipe insulation material and the


indoor unit pipe insulation material. Bind them together with
vinyl tape so that there may be no gap.
2. Wrap the area which accommodates the rear piping housing section with vinyl tape.

Indoor unit pipe

Connection pipe

Wrap with vinyl tape


Vinyl tape (wide)
Connecting cable
Pipe
Vinyl tape(narrow)

3. Bundle the piping and drain hose together by wrapping


them with vinyl tape sufficient enough to cover where they
fit into the rear piping housing section.

Wrap with vinyl tape


Pipe

Vinyl tape(wide)
Drain hose

GENERAL WALL MOUNTED

53

Installation

SR-6RMG2-02A

Finishing the indoor unit installation


1. Mount the tubing holder in the original positon.
2. Ensure that the hooks are properly seated on the installation plate by moving it left and right.
3. Press the lower left and right sides of the unit against the
installation plate until the hooks engage into their slots
(clicking sound).
4. Finish the assembly by screwing the unit to the installation
plate by using two pieces of type "C" screws. And assemble
a chassis cover.
5. Reconvey the chassis cover in Original place.
Type 'C' screw

Outdoor Unit Installation


1. Remove the tubing cover from the unit by loosening the
screw.

Cover control

Tubing Cover

2. Align the center of the pipings and sufficiently tighten the


flare nut by hand.

54

GENERAL WALL MOUNTED

SR-6RMG2-02A

Installation

3. Finally, tighten the flare nut with torque wrench until the
wrench clicks.
When tightening the flare nut with torque wrench, ensure
the direction for tightening follows the arrow on the
wrench.
Outside Diameter
mm
inch
6.35
1/4
9.52
3/8
12.7
1/2
15.88
5/8
19.05
3/4

Torque
kgfcm
180~250
340~420
550~660
630~820
990~1210

Nm
17.6~24.5
33.3~41.2
53.9~64.7
61.7~80.4
97~118.6

Outdoor unit
Gas side

3-way valve

Liquid side

3-way or
2-way valve

Cap

GENERAL WALL MOUNTED

55

Installation

SR-6RMG2-02A

12.8 Connecting the Cables


Indoor
Connect the cable to the indoor unit by connecting the wires to the terminals on the control board individually according to the
outdoor unit connection. (Ensure that the color of the wires of the outdoor unit and the terminal No. are the same as those of
the indoor unit.)

CAUTION
The circuit diagram is a subject to change without notice.
The earth wire should be longer than the common wires.
When installing, refer to the circuit diagram on the chassis cover.
Connect the wires firmly so that they may not be pulled out easily.
Connect the wires according to color codes, referring to the wiring diagram.

CAUTION
The power cord connected to the unit should be selected according to the following specifications (Cable Type
approved by IEC 60245 or IEC 60227).
(mm2)

mm

10

POWER CORD
Capacity
[kW (Btu/h)]
Nomal CrossSection Area
Unit
Cable Type

GN

/YL
20

mm

5.3 (18)

7.0 (24)

1.5

2.5

Indoor
H05VV-F

Indoor
H05VV_F

The power connecting cable connecting the indoor and outdoor unit should be selected according to the following
specifications (Cable type approved by IEC 60245 or IEC 60227).

10

mm

GN

mm

10

10

mm

GN

/YL

/YL

20

mm

20

mm

(mm2)
POWER CONNECTING CABLE
Capacity
5.3 (18)
7.0 (24)
[kW (Btu/h)]
Nomal Cross1.5
2.5
Section Area
Unit
Indoor
Indoor
Cable Type
H07RN-F
H07RN-F

56

(mm2)
COMMUNICATION CONNECTING CABLE
Capacity
5.3 (18)
7.0 (24)
[kW (Btu/h)]
Nomal Cross0.75
0.75
Section Area
Unit
Indoor
Indoor
Cable Type
H05RN-F
H05RN-F

GENERAL WALL MOUNTED

SR-6RMG2-02A

Installation

Outdoor

CAUTION

1 Remove the control cover from the unit by loosening the


screw. Connect the wires to the terminals on the control
board individually.
2 Secure the cable onto the control board with the cord
clamp.
3 Refix the control cover to the original position with the
screw.
4 Use a recognized circuit breaker between the power source
and the unit.
A disconnecting device to adequately disconnect all supply
lines must be fitted.

Capacity [kW (kBtu/h)]


5.3 (18)
7.0 (24)
20
30

Circuit
Breaker (A)

Provide the circuit breaker between power source and the


unit as shown by
Main power source

Air
Conditioner

Circuit Breaker
Use a circuit breake
or time delay fuse.

CAUTION
According to the confirmation of the above conditions, prepare the wiring as follows.

CASE 1

The earth
earth wire
wire should
should
The
be
longer
than
the
be longer than the
common wires.
wires.
common

1(L) 2(N) 3

CASE 2

1(L) 2(N)

1. Never fail to have an individual power circuit specifically for


the air conditioner. As for the method of wiring, be guided
by the circuit diagram posted on the inside of control cover.

CASE 3

2. The screw which fasten the wiring in the casing of electrical


fittings are liable to become loose from vibrations to which
the unit is subjected during the transportation. Check them
and make sure that They all are tightly fastened. (If they
are loose, it could cause burn-out of the wires.)

1(L) 2(N) 3

3. Specification of power source.

Connecting
cable
Cover control

* Round Pressure terminal and connecting requirement

4. Confirm that electrical capacity is sufficient.


5. See that the starting voltage is maintained at more than 90
percent of the rated voltage marked on the name plate.
6. Confirm that the cable thickness is as specified in the
power source specification.
(Particularly note the relation between cable length and
thickness.
7. Always install an earth leakage circuit breaker in a wet or
moist area.
8. The following would be caused by voltage drop.
- Vibration of a magnetic switch, which will damage the
contact point, fuse breaking, disturbance of the normal
function of the overload.

Over
5mm
Round pressure
terminal

Power wire

9. The means for disconnection from a power supply shall be


incorporated in the fixed wiring and have an air gap contact
separation of at least 3mm in each active(phase) conductors.

GENERAL WALL MOUNTED

57

Installation

SR-6RMG2-02A

12.9 Checking the Drainage


To check the drainage.
1. Pour a glass of water on the evaporator.
2 Ensure the water flows through the drain hose of the
indoor unit without any leakage and goes out the drain
exit.

Connecting area
drain hose
Leakage
checking

Drain Pan
Leakage
Checking

Drain
Hose

Drain piping
1. The drain hose should point downward for easy drain flow.

Downward slope

2. Do not set the drain hose like the following.

Accumulated
drain water
Air

Do not raise

Water
leakage

Water
leakage

Waving

Tip of drain hose


dipped in water
Water
leakage

*The feature can be changed according to the type of model.

58

GENERAL WALL MOUNTED

Ditch

Less than
50mm gap

SR-6RMG2-02A

Installation

12.10 Forming the Piping


Form the piping by wrapping the connecting portion of the indoor unit with insulation material and
secure it with two kinds of vinyl tapes.

Pipe
Drain hose
Vinyl tape(narrow)

- If you want to connect an additional drain hose, the


end of the drain outlet should be routed above the
ground. Secure the drain hose appropriately.
Wrap with
vinyl tape(wide)

In cases, where the outdoor unit is installed below


the Indoor unit, perform the following.
1. Tape the piping, drain hose and connecting cable
from down to up.
2. Secure the tapped piping along the exterior wall
using saddle or equivalent.

Seal small openings


around pipings with a
gum type sealant.

Saddle

Connecting cable
Pipings

Taping
Drain hose

Trap is required to prevent water


from entering into electrical parts.

In cases, where the outdoor unit is installed above


the Indoor unit, perform the following.
1. Tape the piping and connecting cable from down to up.

Seal a small opening


around the pipings
with gum type sealant.

2. Secure the taped piping along the exterior wall. Form a


trap to prevent water entering the room.
3. Fix the piping onto the wall using saddle or equivalent

Trap

Trap

GENERAL WALL MOUNTED

59

Installation

SR-6RMG2-02A

12.11 Air Purging


The air and moisture remaining in the refrigerant system have undesirable effects as indicated below.
1. Pressure in the system rises.
2. Operating current rises.
3. Cooling(or heating) efficiency drops.
4. Moisture in the refrigerant circuit may freeze and block capillary tubing.
5. Water may lead to corrosion of parts in the refrigeration system.
Therefore, after evacuating the system, take a leak test for the piping and tubing between the indoor and outdoor unit.

Air purging with vacuum pump


1. Preparation
Check that each tube(both liquid and gas side tubes) between the indoor and outdoor units have been properly connected and all
wiring for the test run has been completed. Remove the service valve caps from both the gas and the liquid side on the outdoor unit.
Note that both the liquid and the gas side service valves on the outdoor unit are kept closed at this stage.
2. Leak test
Connect the manifold valve(with pressure gauges) and dry nitrogen gas cylinder to this service port with charge hoses.

CAUTION
Be sure to use a manifold valve for air purging. If it is not available, use a stop valve for this purpose. The knob of the 3-way
valve must always be kept close.
- Pressurize the system to maximum 250 P.S.I.G. (R-22 model) or 400 P.S.I.G (R-410A model) with dry Nitrogen gas and
close the cylinder valve when the gauge reading reaches 250 P.S.I.G (R-22 model) or 400 P.S.I.G (R-410A model). Next
step is leak test with liquid soap.

CAUTION
To avoid nitrogen entering the refrigerant system in a liquid state, the top of the cylinder must be higher than its bottom when
you pressurize the system. Usually, the cylinder is used in a vertical standing position.

WARNING
There is a risk of fire and explosion.
Inert gas (nitrogen) should be used when you check plumbing leaks, cleaning or repairs of pipes etc.
If you are using combustible gases including oxygen, product may have the risk of fires and explosions.
1. Do a leak test of all joints of the tubing(both indoor and outdoor) and both gas and liquid side service valves.
Bubbles indicate a leak. Be sure to wipe off the soap with a
clean cloth.
2. After the system is found to be free of leaks, relieve the nitrogen pressure by loosening the charge hose connector at the
nitrogen cylinder. When the system pressure is reduced to
normal, disconnect the hose from the cylinder.

Indoor unit

Lo

Charge hose
Nitrogen gas
cylinder
(in vertical
standing position)

*The feature can be changed according a type of model.


Outdoor unit

60

GENERAL WALL MOUNTED

Manifold valve
Pressure
gauge
Hi

SR-6RMG2-02A

Installation

Soap water method


1. Remove the caps from the 2-way and 3-way valves.
2. Remove the service-port cap from the 3-way valve.
3. Apply a soap water or a liquid neutral detergent on the
indoor unit connection or outdoor unit connections by a
soft brush to check for leakage of the connecting points of
the piping.
4. If bubbles come out, the pipes have leakage

Outdoor unit
Gas side
3-way valve

Liquid side

3-way or
2-way valve

Evacuation
1. Connect the charge hose end described in the preceding
steps to the vacuum pump to evacuate the tubing and indoor
unit.
Confirm the "Lo" knob of the pressure Gauge is open. Then,
run the vacuum pump.
The operation time for evacuation varies with tubing length
and capacity of the pump. The following table shows the time
required for Evacuation.

Cap

Indoor unit

Required time for Evacuation when 30 gal/h vacuum


pump is used
If tubing length is less than
10m (33 ft)

If tubing length is longer


than 10m (33 ft)

10 min. or more

15 min. or more

2. When the desired vacuum is reached, close the knob of the 3way valve and stop the vacuum pump.

Finishing the Job


1. With a service valve wrench, turn the valve of liquid side
counter-clockwise to fully open the valve
2. Turn the valve of gas side counter clockwise to fully open the
valve
3. Loosen the charge hose connected to the gas side service
port slightly to release the pressure, then remove the hose.

Outdoor unit
Manifold valve
Pressure
gauge

4. Replace the flare nut and its bonnet on the gas side service
port and fasten the flare nut securely with an adjustable
wrench. This process is very important to prevent leakage
from the system.

Open

Lo Hi

Close

5. Replace the valve caps at both gas and liquid side service
valves and fasten them tight.
This completes air purging with a vacuum pump.
6. Replace the pipe cover to the outdoor unit by one screw
Now the air conditioner is ready for test run.

Vacuum pump

* The feature can be changed according to the type of model.

GENERAL WALL MOUNTED

61

Installation

SR-6RMG2-02A

Settlement of outdoor unit


1. Fix the outdoor unit with a bolt and nut(10mm) tightly and
horizontally on a concrete or rigid mount.
2. When installing on the wall, roof or rooftop, anchor the
mounting base securely with a nail or wire assuming the
influence of wind and earthquake.
3. If the vibration of the unit is transmitted to the pipe, secure
the unit with an anti-vibration rubber.

Bolt

Tubing connection

Evaluation of the performance


Operate the unit for 15~20 minutes, then check the system
refrigerant charge:
1. Measure the pressure of the gas side service valve.
2. Measure the air temperature from inlet and outlet of air
conditiioner.
3. Ensure the difference between the inlet and outlet temperature is more than 8C.
4. For reference; the gas side pressure at optimum condition
is shown on table (cooling)
The air conditioner is now ready to use.
Refrigerant

Outside
ambient
TEMP.

The pressure of the


gas side service valve.

R22

35C (95F)

4~5kg/cm2G
(56.8~71.0 P.S.I.G.)

R410A

35C(95F)

8.5~9.5kg/cm2G
(120~135 P.S.I.G.)

Intake temperature
Discharge air

Discharge
temperature

*The feature can be changed according a type of model.

NOTE
If the actual pressure is higher than shown, the system is most likely over-charged, and charge should be removed. If the
actual pressure are lower than shown, the system is most likely undercharged, and charge should be added.

Pump down
This is performed when the unit is relocated or the refrigerant circuit is serviced.
Pump Down means collecting all refrigerant into the outdoor unit without the loss of refrigerant.

CAUTION
Be sure to perform Pump Down procedure in the cooling mode.

Pump Down Procedure


1. Connect a low-pressure gauge manifold hose to the charge port on the gas side service valve.
2. Open the gas side service valve halfway and purge the air in the manifold hose using the refrigerant.
3. Close the liquid side service valve(all the way).
4. Turn on the unit's operating switch and start the cooling operation.
5. When the low-pressure gauge reading becomes 1 to 0.5kg/cm2 G(14.2 to 7.1 P.S.I.G.), fully close the gas side valve and
then quickly turn off the unit. Now Pump Down procedure is completed, and all refrigerant is collected into the outdoor unit.

62

GENERAL WALL MOUNTED

SR-6RMG2-02A

Installation

12.12 Installation of filters


1. Pull out the triple filter and allergy free filter from the separately
packed plastic bag.
2. Insert the triple filter into the left case and insert the allergy free
filter into the right case.
3. Detach two nitto tapes from the plasma filter.

Virus & Allergy Safe Filter


+ Triple Filter

Cyclotron
Plasma Filter

* The feature can be changed according to the type of model.

12.13 Test Running


- Check that all tubing and wiring are properly connected.
- Check that the gas and liquid side service valves are fully open.

Prepare remote controller


Insert batteries before using the remote control. The battery
type used is AAA (1.5 V).
1. Remove the battery cover.
2. Insert the new batteries and make sure that the + and - terminals of the batteries are installed correctly.
3. Reattach the battery cover.

NOTE
Use 2 AAA(1.5volt) batteries. Do not use rechargeable
batteries.
Remove the batteries from the remote controller if the system is not used for a long time

GENERAL WALL MOUNTED

63

Installation

SR-6RMG2-02A

12.14 Installation Guide at the Seaside


CAUTION
Air conditioners should not be installed in areas where corrosive gases, such as acid or alkaline gas, are produced.
Do not install the product where it could be exposed to sea wind (salty wind) directly. It can result corrosion on the product.
Corrosion, particularly on the condenser and evaporator fins, could cause product malfunction or inefficient performance.
If outdoor unit is installed close to the seaside, it should avoid direct exposure to the sea wind. Otherwise it needs additional anticorrosion treatment on the heat exchanger.

Selecting the location(Outdoor Unit)


1. If the outdoor unit is to be installed close to the seaside, direct exposure to the sea wind should be avoided. Install the outdoor unit on the opposite side of the sea wind direction.

Sea wind

Sea wind

2. In case, to install the outdoor unit on the seaside, set up a windbreak not to be exposed to the sea wind.

Windbreak

Sea wind

It should be strong enough like concrete to prevent the


sea wind from the sea.
The height and width should be more than 150% of the
outdoor unit.
More than 70cm(s) of space should be kept between
outdoor. Unit and windbreak for easy air flow.
Select a well-drained place.

1. If you cant meet above guide line in the seaside installation, please contact LG Electronics for the additional
anticorrosion.
2. Periodic ( more than once/year ) cleaning of the dust or salt particles stuck on the heat exchanger by using
water

64

GENERAL WALL MOUNTED

P/No.: MFL67839902

Air Conditioner
20 Yeouido-dong, Yeongdeungpo-gu,
Yeouido P.O.Box 335 Seoul,
150-721, Korea.
http://www.lgeaircon.com

All rights reserved


Printed in Korea May / 2013
The specifications, designs, and
information in this brochure are subject to
change without notice.

The air conditioners manufactured by LG have received ISO9001 certificate for


quality assurance and ISO14001 certificate for environmental management system.

Das könnte Ihnen auch gefallen