EDC HAZ-SCANNER MODEL HIM-6000 GAS CONCENTRATION RANGES

HIM-6000 Application Specific Sensors Ranges and


Resolution Specifications
* Mix and match sensors with custom concentration ranges available upon request.
* Please email sales@hazdust.com for information on pricing.

Ambient AQ Applications
For ppb and ug/m trace levels. Calibrated for
US EPA and EU directives

Emergency Response & IAQ Application


For ppm and mg/m concentration levels.

Particulates Sensor:
Display Resolution: 1 ug/m3.
Sensor Minimum Resolution: 10ug/m3.
Sensor Accuracy: < +/- 10% of reading or 0.2%
Full Scale - whichever is greater.
Measurement/Concentration Range: 0-5000
ug/m3.

Particulates Sensor:
Display Resolution: 1 ug/m3.
Sensor Minimum Resolution: 10ug/m3.
Sensor Accuracy: < +/- 10% of reading or 2% Full
Scale - whichever is greater.
Measurement/Concentration Range: 0-20000 ug/m3.

P/N HS-PSPM-1.0
HS-PSPM-2.5
HS-PSPM-10
* Choose two sensors for true simultaneous
particulate monitoring.

P/N GB-PSPM-1.0
GB-PSPM-2.5
GB-PSPM-10
* Choose two sensors for true simultaneous
particulate monitoring.

Ammonia (NH3) Sensor


Display Resolution: 0.1 ppm.
Sensor Minimum Resolution: <1.5 ppm.
Sensor Accuracy: < +/- 10% of reading or 2%
Full Scale - whichever is greater.
Measurement/Concentration Range: 0-100 ppm.

Ammonia (NH3) Sensor


Display Resolution: 0.1 ppm.
Sensor Minimum Resolution: <1.5 ppm.
Sensor Accuracy: < +/- 10% of reading or 2% Full
Scale - whichever is greater.
Measurement/Concentration Range: 0-100 ppm.

P/N HS-NH3-6000

P/N HS-NH3-6000

Carbon Monoxide (CO) Sensor:


Display Resolution: 1ppb.
Sensor Minimum Resolution: 20 ppb.
Sensor Accuracy: < +/- 10% of reading or 2%
Full Scale - whichever is greater.
Measurement/Concentration Range: 0-10,000
ppb (0-10ppm).

Carbon Monoxide (CO) Sensor:


Display Resolution: 0.1 ppm.
Sensor Minimum Resolution: <1.5 ppm.
Sensor Accuracy: < +/- 10% of reading or 2% Full
Scale - whichever is greater.
Measurement/Concentration Range: 0-1000 ppm.
P/N GB-CO-2000

P/N HS-CO-6000

Environmental Devices Corporation* 4 Wilder Drive #15 * Plaistow, NH 03865 USA* Email Sales: sales@hazdust.com Technical
Support: techsupport@hazdust.com Phone (800) 234-2589
Fax (603) 378-2113

Carbon Dioxide (CO2) Sensor:


Display Resolution: 1 ppm.
Sensor Minimum Resolution: 50 ppm.
Sensor Accuracy: < +/- 10% of reading or 2%
Full Scale - whichever is greater.
Measurement/Concentration Range: 0-5,000
ppm.

Carbon Dioxide (CO2) Sensor:


Display Resolution: 1 ppm.
Sensor Minimum Resolution: 50 ppm.
Sensor Accuracy: < +/- 10% of reading or 2% Full
Scale - whichever is greater.
Measurement/Concentration Range: 0-10,000 ppm.

P/N HS-CO2-6000
P/N HS-CO2-2000
Hydrogen Sulfide (H2S) Sensor
Display Resolution: 1 ppb.
Sensor Minimum Resolution: 20 ppb
Sensor Accuracy: < +/- 10% of reading or 2%
Full Scale - whichever is greater.
Measurement/Concentration Range: 0-5,000 ppb

Hydrogen Sulfide (H2S) Sensor


Display Resolution: 0.1 ppm
Sensor Minimum Resolution: <0.2 ppm.
Sensor Accuracy: < +/- 10% of reading or 2% Full
Scale - whichever is greater.
Measurement/Concentration Range: 0-100 ppm.

P/N HS-H2S-6000

P/N GB-H2S-2000

Methane (CH4) Sensor: (NOTE: not


approved for intrinsically safe applications)
Display Resolution: 50 ppm / 0.1% LEL.
Sensor Minimum Resolution: +/- 50 ppm / 0.1%
LEL.
Sensor Accuracy: < +/- 10% of reading or 2%
Full Scale - whichever is greater.
Measurement/Concentration Range: 0-.5% by
volume, 0-10% LEL 5,000 ppm.

Methane (CH4) Sensor: (NOTE: not approved


for intrinsically safe applications)
Display Resolution: 50 ppm / 0.1% LEL.
Sensor Minimum Resolution: +/- 50 ppm / 0.1%
LEL.
Sensor Accuracy: < +/- 10% of reading or 2% Full
Scale - whichever is greater.
Measurement/Concentration Range: 0-.5% by
volume, 0-10% LEL 5,000 ppm.

P/N HS-CH4-6000

P/N HS-CH4-6000

(Non-Methane) Hydrocarbons (HC) Sensors:


(Ethane, Propane, Butane, Hexane, Ethanol,
Ethylene, Ethylene Oxide)
Display Resolution: 50 ppm / 0.1% LEL.
Sensor Minimum Resolution: +/- 50 ppm / 0.1%
LEL.
Sensor Accuracy: < +/- 10% of reading or 2%
Full Scale - whichever is greater.
Measurement/Concentration Range: 20% LEL.

(Non-Methane) Hydrocarbons (HC) Sensors:


(Ethane, Propane, Butane, Hexane, Ethanol,
Ethylene, Ethylene Oxide)
Display Resolution: 50 ppm / 0.1% LEL.
Sensor Minimum Resolution: +/- 50 ppm / 0.1%
LEL.
Sensor Accuracy: < +/- 10% of reading or 2% Full
Scale - whichever is greater.
Measurement/Concentration Range: 20% LEL.

P/N HS-H-6000

P/N HS-H-6000

Environmental Devices Corporation* 4 Wilder Drive #15 * Plaistow, NH 03865 USA* Email Sales: sales@hazdust.com Technical
Support: techsupport@hazdust.com Phone (800) 234-2589
Fax (603) 378-2113

Nitrogen Dioxide (NO2) Sensor:


Display Resolution: 1 ppb.
Sensor Minimum Resolution: 20 ppb.
Sensor Accuracy: < +/- 10% of reading or 2%
Full Scale - whichever is greater.
Measurement/Concentration Range: 0-5,000
ppb.

Nitrogen Dioxide (NO2) Sensor:


Display Resolution: 0.01 ppm.
Sensor Minimum Resolution: 0.05 ppm.
Sensor Accuracy: < +/- 10% of reading or 2% Full
Scale - whichever is greater.
Measurement/Concentration Range: 0-20 ppm.

P/N GB-N02-2000
P/N HS-N02-6000
Oxygen (O2) Sensor:
Display Resolution: 0.1 %.
Sensor Minimum Resolution: 0.6%.
Sensor Accuracy: < +/- 10% of reading or 2%
Full Scale - whichever is greater.
Measurement/Concentration Range: 0-30% Vol.

Oxygen (O2) Sensor:


Display Resolution: 0.1 %.
Sensor Minimum Resolution: 0.6%.
Sensor Accuracy: < +/- 10% of reading or 2% Full
Scale - whichever is greater.
Measurement/Concentration Range: 0-30% Vol.

P/N HS-02-6000

P/N GB-02-6000

Ozone (O3) Sensor:


Display Resolution: 1 ppb.
Sensor Minimum Resolution: 1 ppb.
Sensor Accuracy: < +/- 10% of reading or 2%
Full Scale - whichever is greater.
Measurement/Concentration Range: 0-150 ppb
(0.15 ppm)

Ozone (O3) Sensor:


Display Resolution: ppb.
Sensor Minimum Resolution: 5 ppb.
Sensor Accuracy: < +/- 10% of reading or 2% Full
Scale - whichever is greater.
Measurement/Concentration Range: 0-500 ppb (0.5
ppm).
P/N GB-03-0.5

P/N HS-03-6000
Ozone (O3) Sensor:
Display Resolution: 0.01 ppm.
Sensor Minimum Resolution: 0.01 ppm.
Sensor Accuracy: < +/- 10% of reading or 2% Full Scale
- whichever is greater.
Measurement/Concentration Range: 0-10 ppm.

P/N-GB-03-10

Environmental Devices Corporation* 4 Wilder Drive #15 * Plaistow, NH 03865 USA* Email Sales: sales@hazdust.com Technical
Support: techsupport@hazdust.com Phone (800) 234-2589
Fax (603) 378-2113

Sulfur Dioxide (SO2) Sensor:


Display Resolution: 1 ppb
Sensor Minimum Resolution: 20 ppb
Sensor Accuracy: < +/- 10% of reading or 2%
Full Scale - whichever is greater.
Measurement/Concentration Range: 0-5,000
ppb.

Sulfur Dioxide (SO2) Sensor:


Display Resolution: 0.01 ppm.
Sensor Minimum Resolution: 0.05 ppm.
Sensor Accuracy: < +/- 10% of reading or 2% Full
Scale - whichever is greater.
Measurement/Concentration Range: 0-20 ppm.
P/N GB-S02-2000

P/N HS-S02-6000
Volatile Organic Compounds (VOC) Sensor:
Display Resolution: 1 ppb.
Sensor Minimum Resolution: 5ppb.
Sensor Accuracy: Greater of < +/- 10% of
reading or 2% of full scale.
Measurement /Concentration Range: 0-50,000
ppb (0-50ppm).

Volatile Organic Compounds (VOC) Sensor:


Display Resolution: 0.1 ppm.
Sensor Minimum Resolution: 0.1 ppm.
Sensor Accuracy: < +/- 10% of reading or 2% Full
Scale - whichever is greater.
Measurement/Concentration Range: 0-2000 ppm.

P/N GB-VOC-2000
P/N HS-VOC-6000

Exotic Sensors:
Chlorine & Hydrogen Cyanide
General Specification*
Display Resolution: 0.1 ppm.
Sensor Minimum Resolution: <0.2 ppm.
Sensor Accuracy: < +/- 10% of reading or 2%
Full Scale - whichever is greater.
Measurement/Concentration Range: 0-100 ppm.
* Individual specialty sensor concentration
ranges can vary.

Exotic Sensors:
Chlorine & Hydrogen Cyanide
Display Resolution: 0.1 ppm.
Sensor Minimum Resolution: <0.2 ppm.
Sensor Accuracy: < +/- 10% of reading or 2% Full
Scale - whichever is greater.
Measurement/Concentration Range: 0-100 ppm.
* Individual specialty sensor concentration ranges
can vary.

Environmental Devices Corporation* 4 Wilder Drive #15 * Plaistow, NH 03865 USA* Email Sales: sales@hazdust.com Technical
Support: techsupport@hazdust.com Phone (800) 234-2589
Fax (603) 378-2113