Beruflich Dokumente
Kultur Dokumente
72 x 72 analogue ammeters
and voltmeter
Function
PB101118-30_c
PB101119-30_c
PB101116-30_c
bb Consumption: 3 VA.
bb Permanent overload: 1.2 Un.
bb Maximum overload for 5 s: 2 Un.
Catalogue numbers
Type
AMP for standard feeder
Basic device (delivered without dial)
1.3 In dial
Scale
Connection
on CT
Cat. no.
0-50 A
0-100 A
0-200 A
0-400 A
0-600 A
0-1000 A
0-1250 A
0-1500 A
0-2000 A
X/5
50/5
100/5
200/5
400/5
600/5
1000/5
1250/5
1500/5
2000/5
16004
16009
16010
16011
16012
16013
16014
16015
16016
16019
0-30-90 A
0-75-225 A
0-200-600 A
X/5
30/5
75/5
200/5
16003
16006
16007
16008
VLT
0-500 V
16005
23
PLSED309005EN_book.indb 23
13/03/12 09:14
Panel instruments
96 x 96 analogue ammeters
and voltmeter
Function
PB101118-40_c
PB101119-40_c
PB101116-40_c
Catalogue numbers
Type
VLT.
Scale
Connection
on CT
Cat. no.
0-50 A
0-100 A
0-200 A
0-400 A
0-600 A
0-1000 A
0-1250 A
0-1500 A
0-2000 A
0-2500 A
0-3000 A
0-4000 A
0-5000 A
0-6000 A
X/5
50/5
100/5
200/5
400/5
600/5
1000/5
1250/5
1500/5
2000/5
2500/5
3000/5
4000/5
5000/5
6000/5
16074
16079
16080
16081
16082
16083
16084
16085
16086
16087
16088
16089
16090
16091
16092
0-30-90 A
0-75-225 A
0-200-600 A
X/5
30/5
75/5
200/5
16073
16076
16077
16078
VLT
0-500 V
16075
24
PLSED309005EN_book.indb 24
13/03/12 09:14
Panel instruments
Function
050740-25_c
CMA.
bb Durability:
vv electrical: 100 000 operations
vv mechanical: 2 000 000 operations.
bb AgNi contact.
bb Operating temperature: -25C to +50C.
bb Compliance with standards IEC/EN 60947-3.
bb Degree of protection:
vv IP65 on front face
vv IP20 at terminal level.
CMV.
Catalogue numbers
Type
CMA
CMV
Rating
(A)
20
Voltage
(V)
500
DB117274
Connection
DB114275
CMA.
CMV.
25
PLSED309005EN_book.indb 25
13/03/12 09:14
Panel instruments
Function
059197_c
CMA
This 4-position ammeter selector switch uses a single ammeter (using current
transformers) for successive measurement of the currents of a three-phase circuit.
CMV
This 7-position voltmeter selector switch uses a single voltmeter for successive
measurement of voltages (phase-to-phase and phase-to-neutral) of a three-phase
circuit.
CMA.
059198_c
bb Rotary handle.
bb Maximum operating voltage: 440 V, 50/60 Hz.
bb Nominal thermal current: 10 A.
bb Operating temperature: -20C to +55C.
bb Storage temperature: -25C to +80C.
bb Mechanical durability (AC21A-3 x 440 V): 2 000 000 operations.
bb Degree of protection:
vv IP66 on front face
vv IP20 at terminal level.
bb Electrical durability: 1 000 000 operations.
bb Connection: jumper terminals with captive screws, for cables up to 1.5 mm2.
bb Complies with standards: IEC/EN 60947-3.
CMV.
Catalogue numbers
Type
CMA
CMV
Rating
(A)
Voltage
(V AC)
Width in
mod. of 9 mm
Cat. no.
10
10
415
415
4
4
15126
15125
DB114272
Connection
DB114273
CMA.
CMV.
26
PLSED309005EN_book.indb 26
13/03/12 09:14
CH hour counters
Panel instruments
Function
DB119002
bb Electromechanical display.
bb Maximum display: 99999.99 hours.
bb Display accuracy: 0.01 %.
bb Without reset.
bb Storage temperature: -25C to +85C.
bb Connection: tunnel terminals for 2.5 mm2 cable.
CH "DIN".
DB119003
CH "DIN"
bb Consumption: 0.15 VA.
bb Operating temperature: -10C to +70C.
bb Mounting on DIN rail.
CH "48 x 48"
bb Consumption:
vv 15607: 0.25 VA
vv 15608: 0.15 VA
vv 15609: 0.02 VA to 12 V and 0.3 VA to 36 V.
bb Operating temperature: -20C to + 70C.
bb Degree of protection: IP65 on front face.
bb Mounting on front face of monitoring switchboards.
Catalogue numbers
CH "48 x 48".
Type
CH "DIN"
CH "48 x 48"
Voltage
Width in mod.
(V)
of 9 mm
230 V AC 10 %/50 Hz 4
24 V AC 10 %/50 Hz
230 V AC 10 %/50 Hz
12 to 36 V DC
Cat. no.
15440
15607
15608
15609
DB114263
DB114262
Connection
load
CH "DIN".
load
CH "48 x 48".
27
PLSED309005EN_book.indb 27
13/03/12 09:14
CI impulse counter
Panel instruments
Function
DB119004
Catalogue number
Type
CI
Width in mod.
of 9 mm
4
Cat. no.
15443
DB114271
Connection
load
load
28
PLSED309005EN_book.indb 28
13/03/12 09:14
Dimensions
Panel instruments
Capot de protection
Ammeters, voltmeters,
selector switches,
impulse counter, hour counters
DB103473
Capot de protection
DB103474 converti
DB103475 converti
DB103476
DB103481
29
PLSED309005EN_book.indb 29
13/03/12 09:14
Dimensions (cont.)
Panel instruments
DB103477
(with adapter)
DB103479 converti
DB109825 converti
48 x 48 CH hour counters
30
PLSED309005EN_book.indb 30
13/03/12 09:14
Panel instruments
DM6000 series
PE86238
The PowerLogic DM6000 series digital panel meters offer the basic measurement
capabilities required to monitor an electrical installation.
Characterized by their rugged construction, compact size, and low installation costs,
these state-of-the-art meters are ideal for control panels, motor control centres and
genset panels.
The PowerLogic DM6000 series digital meter is available in two different versions to
better fit specific applications:
DM6000, basic version;
DM6200, basic version plus an RS485 port for Modbus communication.
Applications
PE86261
Main characteristics
Easy to read display
The bright, alphanumeric 15mm high LED display provides 3 lines for measurement
values with 4 digits per line. This display auto-scales for Kilo, Mega and Giga values.
Auto scrolling mode allows for easy reading.
Analogue load bar
The colour-coded analogue load bar indicates the percentage of load through 12
LED segments.
Turbo Key access to information
The Turbo Key gives access to the most commonly viewed parameters or enter set
up mode with a single push of the button.
Quick and easy installation
Setup is done through the front panel keys. Quick entry to setup during power up by
TURBO key. Direct connection for metering voltage inputs up to 480 V AC L-L.
Colour-coded terminal board labeling
The colour-coded label on the terminal board helps ensure accurate wiring.
Secure settings
Safeguard access to setup parameters with unique password protection. A keypad
lock lets you display a user-selected page by default.
Part numbers
Description
Schneider Electric
METSEDM6000
METSEDM6200
31
PLSED309005EN_book.indb 31
13/03/12 09:14
Panel instruments
DM6000 series
PE86239
Selection guide
DM6000 DM6200
General
Other measurements
ON hours
INTR
Display
LED display
Communication
RS-485 port
Modbus protocol
1.0 %
20 at 50 Hz
1.0 %
20 at 50 Hz
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
b
1
b
32
PLSED309005EN_book.indb 32
13/03/12 09:14
Panel instruments
DM6000 series
Electrical characteristics
Type of measurement
Measurement
accuracy*
Frequency
0.1 % of reading
Power factor
1.0 % of reading
* Additional error of 0.05% of full scale, for meter input current below 100mA
Data update rate
Input-voltage
characteristics
1 second
Inputs
Measured voltage
Permissible overload
Burden
Impedance
Frequency range
Input-current
characteristics
Power supply
CT ratings
45 - 65 Hz
Primary
1 A - 99.0 kA
Secondary
1A- 5A
Measurement range
50 mA - 6 A (5 mA is the starting)
Permissible overload
Burden
10 A continuous
0.2 VA per phase max.
Impedance
AC
44 - 277 V AC at 50 Hz/60 Hz
DC
44 - 277 V DC
Ride-through time
100 ms at 50 V
Burden
3 VA max.
Mechanical characteristics
Weight
IP degree of protection
Dimensions
Environmental conditions
Operating temperature
Storage temperature
Humidity rating
Altitude
Measurement CAT
Pollution degree
Protection class
Electromagnetic compatibility
Electrostatic discharge
Immunity to electromagnetic RF fields
Immunity to electrical fast transients
Immunity to surge waves
Conducted disturbance immunity
Damped oscillatory waves immunity
Impulse voltage withstand
Conducted and radiated emissions
-10C to +60C
-25C to +70C
5 to 95 % RH non-condensing
2000 m
III
2
2
IEC 61000-4-2
IEC 61000-4-3
IEC 61000-4-4
IEC 61000-4-5
IEC 61000-4-6
IEC 61000-4-12
6 kV for 1.2/50 S per IEC 60060-1
CISPR11 Class A, FCC Part 15 Class A
Communication
RS-485 port
Display characteristics
Integrated LED display
33
PLSED309005EN_book.indb 33
13/03/12 09:14
DM6000 series
Panel instruments
PE86240 copie
PE86241 copie
Front-panel mounting
34
PLSED309005EN_book.indb 34
13/03/12 09:14
Panel instruments
DM6000 series
PE86268
PE86269
35
PLSED309005EN_book.indb 35
13/03/12 09:14
Panel instruments
DM6000 series
PE86270
36
PLSED309005EN_book.indb 36
13/03/12 09:14
Kilowatt-hour meters
Kilowatt-hour meters
PB105291
Function
iEM2000T
iME1zr / ME1zr
Single-phase kilowatt-hour meter with partial meter and remote transfer of metering
impulses (relay output).
PB103457_SE-35
iME3 / ME3
Three-phase kilowatt-hour meter without neutral.
iME3zr / ME3zr
Three-phase kilowatt-hour meter without neutral, with partial meter and remote
transfer of metering impulses (relay output).
iME4 / ME4
Three-phase + neutral kilowatt-hour meter.
iME4zr / ME4zr
Three-phase + neutral kilowatt-hour meter with partial meter and remote transfer of
metering impulses (relay output).
iEM1zr/ME1zr.
iME4zrt/ME4zrt
Three-phase kilowatt-hour meter with or without neutral associated with external CTs
(not supplied), with partial meter and remote transfer of metering impulses (relay
output).
Catalogue numbers
PB103459_SE-35
Type
PB103462_SE-35
iME3zr/ME3zr.
Cat. no.
Type
Cat no.
Rating
(A)
Voltage
(V AC)
Tolrance Width in
mod.
(V AC)
40
63
63
63
230
230
230
230
20
20
20
20
2
4
4
4
3 x 400-3 x 230 20
63
3 x 400-3 x 230 20
63
40...6000 3 x 400-3 x 230 20
8
8
8
20
20
20
8
8
8
3 x 230/400
63
3 x 230/400
63
40...6000 3 x 230/400
of9 mm
ME
iEM2000T
Accuracy class
Frequency
Consumption
Operating temperature
1
48/62 Hz
2.5 VA
-25C to +55C
1
48/62 Hz
< 10 VA
-25C to +55C
-25C to +65C (32 A)
Top terminals: 4 mm2
Bottom terminals: 10 mm2
IEC 62053-21 /
IEC 61557-12:
- PMD/DD/K55/1
IEC 62053-21
Yes
37
PLSED309005EN_book.indb 37
13/03/12 09:14
Kilowatt-hour meters
DB105292
Description
iEM2000T
1 Pulse output for remote transfer.
2 Green on/off indicator or to display a wiring error (status: Off).
3 Flashing yellow meter indicator (can be used to check accuracy of the
equipment).
4 Terminal covers and lead sealing accessory.
5 Free holes for the comb busbar.
iEM2000T
DB118760
iMEzr / MEzr.
DB118857
iME4zrt / ME4zrt.
Installation
DB118815
bb The front panel of the product is IP40 and its housing is IP20.
bb Its installation must be appropriate to the operating conditions.
bb The protection must not be less than IP65 for outdoor use.
Circuit-breaker
Contactor
Kilowatt-hour meter
Kilowatt-hour meter
Contactor
Load
Load
38
PLSED309005EN_book.indb 38