E52
A Wide Variety of High-precision
Temperature Sensors
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according to
the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal.
General-purpose, low-cost, and exclusive models are available.
Ordering Information
List of Models
Classification
Generalpurpose
Models
Description
Temperature
range
(See
note.)
Element
type
Sheathed E52-P@A
platinum
resistance E52-P@C
thermometer
200C to Pt100
450C
Standard E52-P@B
platinum
resistance E52-P@C
thermometer
0C to
450C
Sheathed
thermocouple
Standard
thermocouple
E52-CA@A
E52-IC@A
0C to
1,050C
K (CA)
J (IC)
Conductor type
Class
3-conduc- B
tor system
Nongrounded
type
2 (0.75)
Protective
tubing
material
SUS316
SUS316
Inconel
Terminal
type
Page
Exposed F-5
lead wires
Enclosed
terminals
F-6
Exposed
terminals
F-7
Enclosed
terminals
F-7
Exposed F-9
lead wires
E52-CA@B
E52-IC@B
Exposed
terminals
F-13
E52-CA@C
E52-IC@C
Enclosed
terminals
F-13
Exposed
terminals
F-14
Enclosed
terminals
F-15
Enclosed
terminals
F-16
E52-CA@B
E52-IC@B
0C to
1,000C
SUS316
SUS310S
E52-CA@C
E52-IC@C
E52-PR@C
0C to
1,400C
R (PR)
2 (0.25)
JIS ceramic
JIS special
ceramic
Temperature Sensor
E52
F-1
Classification
Low-cost
Models
Description
Low-cost E52-P10AE
E52-P6D
platinum
resistance E52-P6F
thermometer
Low-cost
thermocouple
E52-CA@AS
E52-IC@AS
Temperature
range
(See
note.)
Element
type
Conductor type
Class
50C to
250C
Pt100
3-conduc- B
tor system
0C to
400C
K (CA)
J (IC)
Nongrounded
type
Protective
tubing
material
SUS304
Terminal
type
Exposed F-18
lead wires
2 (0.75)
F-19
E52-CA1D
E52-IC1D
E52-CA6F
E52-IC6F
Grounded
type
F-20
E52-CA10AE
E52-IC10AE
Nongrounded
type
F-22
F-2
Page
Classification
Description
Exclusive
Models
Bayonet
spring for
molding
machines
E52-CA2GV
E52-IC2GV
0C to
350C
Crimping
terminals
E52-CA1GT
E52-IC1GT
0C to
300C
Element
type
K (CA)
J (IC)
Conductor type
Class
Grounded 2 (0.75)
type
Protective
tubing
material
SUS304
Terminal
type
Page
Exposed F-22
lead wires
F-23
E52-P2GS
Used for
measuring surface
temperatures
50C to
250C
E52-P10GR
Used for
room temperature
measurement
50C to
60C
Double-el- E52-P20GW
ement
model
50C to
250C
Two 3-conductor
systems
F-24
E52-P10GP
Waterproof model
E52-P5A-40
0C to
70C
3-conductor system
F-25
Corrosion- E52-@@A-1
resistant
model
80C to
180C
Used for
movable
parts
E52-CA1D-40
Explosion- E52-@@C-6
proof model
Thermistors
Temperature
range
(See
note.)
E52-THE5A
E52-THE6F
E52-THE6D
Pt100
3-conduc- B
tor system
F-23
F-24
50C to
180C
PFA molding
F-26
Pt100
3-conduc- B
tor system
K (CA)
Nongrounded
type
K (CA)
Grounded 2 (0.75)
type
---
100C to Pt100
500C
3-conduc- B
tor system
SUS316
Enclosed
terminals
100C to K (CA)
900C
Nongrounded
type
SUS304
Exposed F-31
lead wires
0C to
300C
50C to
300C
PFA tubing
F-25
2 (0.75)
F-29
F-27
2 (0.75)
Thermistor Element- 1
interchangeable
thermistor
Note: 1. General-purpose models and low-cost models are provided on the previous pages.
2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use.
3. The temperature range varies with the material, thickness, and construction of the protective tubing.
Temperature Sensor
E52
F-3
Accessories
It is recommended that the following accessories be used for mounting Temperature Sensors.
Accessory
Temperature
range
600C max.
Compression
Fitting
Mounting example
Page
F-32
Mounting with
Compression
Fitting
Terminal box
Compression Fitting
PT screw
Welding
400C max.
Loose Flange
Protective tubing
Mounting with
Loose Flange
Terminal box
Loose Flange
Protective tubing
Mounting screw
Lead Wires
Accessory
For resistance thermometers
For thermocouples
(compensating conductor)
Specification
Vinyl-covered with twelve 0.18-dia. conductors (0.3 mm thick) and 4.8
mm in outer dia.
Heat resistive
Standard
20C to 70C
Heat resistive
0C to 150C
Sleeve: 0C to 100C
General-purpose Models
Sheathed Platinum Resistance Thermometers
Refer to Model Number Legend on page F-8 for the Pt100.
Specifications
Element type
Pt100
Class
JIS class B
Sheath material
SUS316
Conductor type
3-conductor system
Temperature range
F-4
Temperature range
20C to 70C
Standard
Page
---
F-34
Exposed-lead Models
E52-P@A
Dimensions
Red (A)
Unit (mm)
SUS304 sleeve
Black (B)
3.2 dia.
60
4.8 dia.
60
6.4 dia.
60
SUS316 sheath
White (B)
D
L
Lead Wire
Standard (20C to 70C):
Fully vinyl-covered with twelve 0.18-dia
conductors (0.3 mm thick) and 4.8 mm
in outer dia. The sleeve resists a
temperature range between 0C and
70C.
Heat Resistive (0C to 180C):
Fully glass-wool-covered with twenty
0.18-dia. conductors (0.5 mm thick)
externally shielded, 5.2 mm in outer
dia. The sleeve resists a temperature
range between 0C and 100C.
Lead Wire Length (M): 1, 2, 4, or 8 m
Model Information
Custom-made models are available on request. Refer to page F-8 for details.
Terminal type
Exposed-lead
Models
Protective
tubing
diameter D
(mm)
3.2 dia.
Protective
tubing length
L (cm)
15
35
20
35
50
6.4 dia.
Model
20
4.8 dia.
Lead wire
type
20
35
50
Standard
E52-P15A D=3.2
1M
E52-P15A D=3.2
2M
E52-P15A D=3.2
4M
E52-P15A D=3.2
8M
Heat resistive
E52-P15A D=3.2
NETU 1M
E52-P15A D=3.2
NETU 2M
E52-P15A D=3.2
NETU 4M
E52-P15A D=3.2
NETU 8M
Standard
E52-P20A D=3.2
1M
E52-P20A D=3.2
2M
E52-P20A D=3.2
4M
E52-P20A D=3.2
8M
Heat resistive
E52-P20A D=3.2
NETU 1M
E52-P20A D=3.2
NETU 2M
E52-P20A D=3.2
NETU 4M
E52-P20A D=3.2
NETU 8M
Standard
E52-P35A D=3.2
1M
E52-P35A D=3.2
2M
E52-P35A D=3.2
4M
E52-P35A D=3.2
8M
Heat resistive
E52-P35A D=3.2
NETU 1M
E52-P35A D=3.2
NETU 2M
E52-P35A D=3.2
NETU 4M
E52-P35A D=3.2
NETU 8M
Standard
E52-P20A D=4.8
1M
E52-P20A D=4.8
2M
E52-P20A D=4.8
4M
E52-P20A D=4.8
8M
Heat resistive
E52-P20A D=4.8
NETU 1M
E52-P20A D=4.8
NETU 2M
E52-P20A D=4.8
NETU 4M
E52-P20A D=4.8
NETU 8M
Standard
E52-P35A D=4.8
1M
E52-P35A D=4.8
2M
E52-P35A D=4.8
4M
E52-P35A D=4.8
8M
Heat resistive
E52-P35A D=4.8
NETU 1M
E52-P35A D=4.8
NETU 2M
E52-P35A D=4.8
NETU 4M
E52-P35A D=4.8
NETU 8M
Standard
E52-P50A D=4.8
1M
E52-P50A D=4.8
2M
E52-P50A D=4.8
4M
E52-P50A D=4.8
8M
Heat resistive
E52-P50A D=4.8
NETU 1M
E52-P50A D=4.8
NETU 2M
E52-P50A D=4.8
NETU 4M
E52-P50A D=4.8
NETU 8M
Standard
E52-P20A D=6.4
1M
E52-P20A D=6.4
2M
E52-P20A D=6.4
4M
E52-P20A D=6.4
8M
Heat resistive
E52-P20A D=6.4
NETU 1M
E52-P20A D=6.4
NETU 2M
E52-P20A D=6.4
NETU 4M
E52-P20A D=6.4
NETU 8M
Standard
E52-P35A D=6.4
1M
E52-P35A D=6.4
2M
E52-P35A D=6.4
4M
E52-P35A D=6.4
8M
Heat resistive
E52-P35A D=6.4
NETU 1M
E52-P35A D=6.4
NETU 2M
E52-P35A D=6.4
NETU 4M
E52-P35A D=6.4
NETU 8M
Standard
E52-P50A D=6.4
1M
E52-P50A D=6.4
2M
E52-P50A D=6.4
4M
E52-P50A D=6.4
8M
Heat resistive
E52-P50A D=6.4
NETU 1M
E52-P50A D=6.4
NETU 2M
E52-P50A D=6.4
NETU 4M
E52-P50A D=6.4
NETU 8M
Temperature Sensor
E52
F-5
Enclosed-terminal Models
E52-P@C
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
34 dia.
57
SUS316 sheath
D
65
4
16
19
Cap
G3/8, 19 mm between
facing sides, 10 inner
dia. (with 7-inner-dia.
rubber bushing built-in)
35
L
Use wiring terminals that fit M3 screws.
Model Information
Custom-made models are available on request. Refer to page F-8 for details.
Terminal type
4.8 dia.
6.4 dia.
Model
Enclosed-terminal Models 20
E52-P20C D=3.2
E52-P20C D=4.8
E52-P20C D=6.4
35
E52-P35C D=3.2
E52-P35C D=4.8
E52-P35C D=6.4
50
E52-P50C D=3.2
E52-P50C D=4.8
E52-P50C D=6.4
75
---
E52-P75C D=4.8
E52-P75C D=6.4
Specifications
Element type
Pt100
Class
SUS316
Conductor type
3-conductor system
Temperature range
F-6
Exposed-terminal Models
E52-P@B
Dimensions
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters.
Model Information
10
A
50 B
B
20
Three, M3
18
Terminal
type
14 dia.
20 dia.
40
Exposedterminal
Models
Terminal box:
The permissible temperature is 0C to 100C.
Protective
Protective tubing diameter D (mm)
tubing length
8 dia.
L (cm)
Model
20
E52-P20B D=8
35
E52-P35B D=8
50
E52-P50B D=8
Enclosed-terminal Models
E52-P@C
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
98
34 dia.
57
SUS316 protective tubing
10
8 dia.
65
10 dia.
90
14 dia.
Cap
35
G3/8, 19 mm between
facing sides, 10 inner
dia. (with 7-inner-dia.
rubber bushing built-in)
10
40 dia.
Cap
57
G1/2, 15-A ground (with 11-inner-dia.
rubber bushing built-in)
Model Information
Custom-made models are available on request. Refer to page F-8 for details.
Terminal type
Protective tubing
length L (cm)
10 dia.
Model
Enclosed-terminal
Models
20
E52-P20C D=8
---
35
E52-P35C D=8
E52-P35C D=10
50
E52-P50C D=8
E52-P50C D=10
75
---
E52-P75C D=10
100
---
E52-P100C D=10
Temperature Sensor
E52
F-7
5 6
1. Element type
P: Pt100
2. Protective tubing length (L)
Specify the length in centimeters within the following range:
Unit (cm)
E52-@@A
Diameter (D)
Length (L)
3.2
7 to 100
4.8
10 to 600
6.4
13 to 1,300
4. Diameter
3.2: 3.2-mm dia. (Protective tubing construction: Sheathed)
E52-@@A and E52-@@C only
4.8: 4.8-mm dia. (Protective tubing construction: Sheathed)
E52-@@A and E52-@@C only
6.4: 6.4-mm dia. (Protective tubing construction: Sheathed)
E52-@@A and E52-@@C only
8: 8-mm dia. (Protective tubing construction: Standard)
E52-@@B and E52-@@C only
10: 10-mm dia. (Protective tubing construction: Standard)
E52-@@B and E52-@@C only
5. Heat resistance
E52-@@B
Code
Diameter (D)
3.2
Length (L)
Diameter (D)
Length (L)
3.2
12 to 100
4.8
15 to 600
6.4
18 to 1,300
21 to 100
10
26 to 100
Lead type
20C to 70C
Sleeve: 0C to 70C
Vinyl-covered
NETU
0C to 180C
Sleeve: 0C to 100C
Glass-wool-covered,
externally shielded
20 to 100
E52-@@C
Temperature range
---
3. Terminal
A: Exposed lead wires
B: Exposed terminals
C: Enclosed terminals
Note: Lead wires without crimp terminals (Y) are also available.
Examples
Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m
E52-P42A D=4.8 NETU 10M
F-8
Sheathed Thermocouples
Specifications
Element type
K (CA), J(IC)
Class
Element wire
K (CA) SUS316
J (IC) SUS316
650C
450C
Thermal contact
Non-grounded type
1 dia.
Sheath material
CA: SUS316
1.6 dia.
650C
450C
IC: SUS316
3.2 dia.
750C
650C
4.8 dia.
800C
750C
6.4 dia.
800C
750C
8.0 dia.
900C
750C
Exposed-lead Models
E52-CA@A
Dimensions
SUS304 sleeve
(See note 2.)
Unit (mm)
SUS316 sheath
d
White ()
M
1 dia.
40
1.6 dia.
40
1 dia.
650C
3.2 dia.
40
1.6 dia.
650C
D
D
Element wire
K (CA) SUS316
4.8 dia.
40
3.2 dia.
750C
6.4 dia.
10
45
4.8 dia.
800C
8 dia.
10
45
6.4 dia.
800C
8.0 dia.
900C
Protective
Protective
tubing diameter tubing length L
D (mm)
(cm)
Model
Exposed-lead
Models
1 dia.
15
20
35
1.6 dia.
15
20
35
Standard
E52-CA15A D=1 1M
E52-CA15A D=1 2M
E52-CA15A D=1 4M
E52-CA15A D=1 8M
Heat resistive
E52-CA15A D=1
NETU 1M
E52-CA15A D=1
NETU 2M
E52-CA15A D=1
NETU 4M
E52-CA15A D=1
NETU 8M
Standard
E52-CA20A D=1 1M
E52-CA20A D=1 2M
E52-CA20A D=1 4M
E52-CA20A D=1 8M
Heat resistive
E52-CA20A D=1
NETU 1M
E52-CA20A D=1
NETU 2M
E52-CA20A D=1
NETU 4M
E52-CA20A D=1
NETU 8M
Standard
E52-CA35A D=1 1M
E52-CA35A D=1 2M
E52-CA35A D=1 4M
E52-CA35A D=1 8M
Heat resistive
E52-CA35A D=1
NETU 1M
E52-CA35A D=1
NETU 2M
E52-CA35A D=1
NETU 4M
E52-CA35A D=1
NETU 8M
Standard
E52-CA15A D=1.6
1M
E52-CA15A D=1.6
2M
E52-CA15A D=1.6
4M
E52-CA15A D=1.6
8M
Heat resistive
E52-CA15A D=1.6
NETU 1M
E52-CA15A D=1.6
NETU 2M
E52-CA15A D=1.6
NETU 4M
E52-CA15A D=1.6
NETU 8M
Standard
E52-CA20A D=1.6
1M
E52-CA20A D=1.6
2M
E52-CA20A D=1.6
4M
E52-CA20A D=1.6
8M
Heat resistive
E52-CA20A D=1.6
NETU 1M
E52-CA20A D=1.6
NETU 2M
E52-CA20A D=1.6
NETU 4M
E52-CA20A D=1.6
NETU 8M
Standard
E52-CA35A D=1.6
1M
E52-CA35A D=1.6
2M
E52-CA35A D=1.6
4M
E52-CA35A D=1.6
8M
Heat resistive
E52-CA35A D=1.6
NETU 1M
E52-CA35A D=1.6
NETU 2M
E52-CA35A D=1.6
NETU 4M
E52-CA35A D=1.6
NETU 8M
Temperature Sensor
E52
F-9
Terminal type
Protective
Protective
tubing diameter tubing length L
D (mm)
(cm)
Model
Exposed-lead
Models
3.2 dia.
15
20
35
50
4.8 dia.
20
35
50
6.4 dia.
20
35
50
8 dia.
20
35
50
F-10
Standard
E52-CA15A D=3.2
1M
E52-CA15A D=3.2
2M
E52-CA15A D=3.2
4M
E52-CA15A D=3.2
8M
Heat resistive
E52-CA15A D=3.2
NETU 1M
E52-CA15A D=3.2
NETU 2M
E52-CA15A D=3.2
NETU 4M
E52-CA15A D=3.2
NETU 8M
Standard
E52-CA20A D=3.2
1M
E52-CA20A D=3.2
2M
E52-CA20A D=3.2
4M
E52-CA20A D=3.2
8M
Heat resistive
E52-CA20A D=3.2
NETU 1M
E52-CA20A D=3.2
NETU 2M
E52-CA20A D=3.2
NETU 4M
E52-CA20A D=3.2
NETU 8M
Standard
E52-CA35A D=3.2
1M
E52-CA35A D=3.2
2M
E52-CA35A D=3.2
4M
E52-CA35A D=3.2
8M
Heat resistive
E52-CA35A D=3.2
NETU 1M
E52-CA35A D=3.2
NETU 2M
E52-CA35A D=3.2
NETU 4M
E52-CA35A D=3.2
NETU 8M
Standard
E52-CA50A D=3.2
1M
E52-CA50A D=3.2
2M
E52-CA50A D=3.2
4M
E52-CA50A D=3.2
8M
Heat resistive
E52-CA50A D=3.2
NETU 1M
E52-CA50A D=3.2
NETU 2M
E52-CA50A D=3.2
NETU 4M
E52-CA50A D=3.2
NETU 8M
Standard
E52-CA20A D=4.8
1M
E52-CA20A D=4.8
2M
E52-CA20A D=4.8
4M
E52-CA20A D=4.8
8M
Heat resistive
E52-CA20A D=4.8
NETU 1M
E52-CA20A D=4.8
NETU 2M
E52-CA20A D=4.8
NETU 4M
E52-CA20A D=4.8
NETU 8M
Standard
E52-CA35A D=4.8
1M
E52-CA35A D=4.8
2M
E52-CA35A D=4.8
4M
E52-CA35A D=4.8
8M
Heat resistive
E52-CA35A D=4.8
NETU 1M
E52-CA35A D=4.8
NETU 2M
E52-CA35A D=4.8
NETU 4M
E52-CA35A D=4.8
NETU 8M
Standard
E52-CA50A D=4.8
1M
E52-CA50A D=4.8
2M
E52-CA50A D=4.8
4M
E52-CA50A D=4.8
8M
Heat resistive
E52-CA50A D=4.8
NETU 1M
E52-CA50A D=4.8
NETU 2M
E52-CA50A D=4.8
NETU 4M
E52-CA50A D=4.8
NETU 8M
Standard
E52-CA20A D=6.4
1M
E52-CA20A D=6.4
2M
E52-CA20A D=6.4
4M
E52-CA20A D=6.4
8M
Heat resistive
E52-CA20A D=6.4
NETU 1M
E52-CA20A D=6.4
NETU 2M
E52-CA20A D=6.4
NETU 4M
E52-CA20A D=6.4
NETU 8M
Standard
E52-CA35A D=6.4
1M
E52-CA35A D=6.4
2M
E52-CA35A D=6.4
4M
E52-CA35A D=6.4
8M
Heat resistive
E52-CA35A D=6.4
NETU 1M
E52-CA35A D=6.4
NETU 2M
E52-CA35A D=6.4
NETU 4M
E52-CA35A D=6.4
NETU 8M
Standard
E52-CA50A D=6.4
1M
E52-CA50A D=6.4
2M
E52-CA50A D=6.4
4M
E52-CA50A D=6.4
8M
Heat resistive
E52-CA50A D=6.4
NETU 1M
E52-CA50A D=6.4
NETU 2M
E52-CA50A D=6.4
NETU 4M
E52-CA50A D=6.4
NETU 8M
Standard
E52-CA20A D=8 1M
E52-CA20A D=8 2M
E52-CA20A D=8 4M
E52-CA20A D=8 8M
Heat resistive
E52-CA20A D=8
NETU 1M
E52-CA20A D=8
NETU 2M
E52-CA20A D=8
NETU 4M
E52-CA20A D=8
NETU 8M
Standard
E52-CA35A D=8 1M
E52-CA35A D=8 2M
E52-CA35A D=8 4M
E52-CA35A D=8 8M
Heat resistive
E52-CA35A D=8
NETU 1M
E52-CA35A D=8
NETU 2M
E52-CA35A D=8
NETU 4M
E52-CA35A D=8
NETU 8M
Standard
E52-CA50A D=8 1M
E52-CA50A D=8 2M
E52-CA50A D=8 4M
E52-CA50A D=8 8M
Heat resistive
E52-CA50A D=8
NETU 1M
E52-CA50A D=8
NETU 2M
E52-CA50A D=8
NETU 4M
E52-CA50A D=8
NETU 8M
Exposed-lead Models
E52-IC@A
Dimensions
Y-type crimp terminal for M4
Red (+)
SUS304 sleeve
(See note 2.)
Unit (mm)
SUS316 sheath
d
White ()
M
1 dia.
40
1.6 dia.
40
1 dia.
450C
3.2 dia.
40
1.6 dia.
450C
4.8 dia.
40
3.2 dia.
650C
6.4 dia.
10
45
4.8 dia.
750C
8 dia.
10
45
6.4 dia.
750C
8.0 dia.
750C
D
D
Element wire
J (IC) SUS316
Exposed-lead
Models
Protective
tubing
diameter D
(mm)
1 dia.
Protective
tubing length
L (cm)
Model
15
20
35
1.6 dia.
Lead wire
type
15
20
35
Standard
E52-IC15A D=1
1M
E52-IC15A D=1
2M
E52-IC15A D=1
4M
E52-IC15A D=1
8M
Heat resistive
E52-IC15A D=1
NETU 1M
E52-IC15A D=1
NETU 2M
E52-IC15A D=1
NETU 4M
E52-IC15A D=1
NETU 8M
Standard
E52-IC20A D=1
1M
E52-IC20A D=1
2M
E52-IC20A D=1
4M
E52-IC20A D=1
8M
Heat resistive
E52-IC20A D=1
NETU 1M
E52-IC20A D=1
NETU 2M
E52-IC20A D=1
NETU 4M
E52-IC20A D=1
NETU 8M
Standard
E52-IC35A D=1
1M
E52-IC35A D=1
2M
E52-IC35A D=1
4M
E52-IC35A D=1
8M
Heat resistive
E52-IC35A D=1
NETU 1M
E52-IC35A D=1
NETU 2M
E52-IC35A D=1
NETU 4M
E52-IC35A D=1
NETU 8M
Standard
E52-IC15A D=1.6
1M
E52-IC15A D=1.6
2M
E52-IC15A D=1.6
4M
E52-IC15A D=1.6
8M
Heat resistive
E52-IC15A D=1.6
NETU 1M
E52-IC15A D=1.6
NETU 2M
E52-IC15A D=1.6
NETU 4M
E52-IC15A D=1.6
NETU 8M
Standard
E52-IC20A D=1.6
1M
E52-IC20A D=1.6
2M
E52-IC20A D=1.6
4M
E52-IC20A D=1.6
8M
Heat resistive
E52-IC20A D=1.6
NETU 1M
E52-IC20A D=1.6
NETU 2M
E52-IC20A D=1.6
NETU 4M
E52-IC20A D=1.6
NETU 8M
Standard
E52-IC35A D=1.6
1M
E52-IC35A D=1.6
2M
E52-IC35A D=1.6
4M
E52-IC35A D=1.6
8M
Heat resistive
E52-IC35A D=1.6
NETU 1M
E52-IC35A D=1.6
NETU 2M
E52-IC35A D=1.6
NETU 4M
E52-IC35A D=1.6
NETU 8M
Temperature Sensor
E52
F-11
Terminal type
Protective
tubing
diameter D
(mm)
Protective
tubing length
L (cm)
15
35
50
20
35
50
6.4 dia.
20
35
50
8 dia.
20
35
50
F-12
Model
20
4.8 dia.
Lead wire
type
Standard
E52-IC15A D=3.2
1M
E52-IC15A D=3.2
2M
E52-IC15A D=3.2
4M
E52-IC15A D=3.2
8M
Heat resistive
E52-IC15A D=3.2
NETU 1M
E52-IC15A D=3.2
NETU 2M
E52-IC15A D=3.2
NETU 4M
E52-IC15A D=3.2
NETU 8M
Standard
E52-IC20A D=3.2
1M
E52-IC20A D=3.2
2M
E52-IC20A D=3.2
4M
E52-IC20A D=3.2
8M
Heat resistive
E52-IC20A D=3.2
NETU 1M
E52-IC20A D=3.2
NETU 2M
E52-IC20A D=3.2
NETU 4M
E52-IC20A D=3.2
NETU 8M
Standard
E52-IC35A D=3.2
1M
E52-IC35A D=3.2
2M
E52-IC35A D=3.2
4M
E52-IC35A D=3.2
8M
Heat resistive
E52-IC35A D=3.2
NETU 1M
E52-IC35A D=3.2
NETU 2M
E52-IC35A D=3.2
NETU 4M
E52-IC35A D=3.2
NETU 8M
Standard
E52-IC50A D=3.2
1M
E52-IC50A D=3.2
2M
E52-IC50A D=3.2
4M
E52-IC50A D=3.2
8M
Heat resistive
E52-IC50A D=3.2
NETU 1M
E52-IC50A D=3.2
NETU 2M
E52-IC50A D=3.2
NETU 4M
E52-IC50A D=3.2
NETU 8M
Standard
E52-IC20A D=4.8
1M
E52-IC20A D=4.8
2M
E52-IC20A D=4.8
4M
E52-IC20A D=4.8
8M
Heat resistive
E52-IC20A D=4.8
NETU 1M
E52-IC20A D=4.8
NETU 2M
E52-IC20A D=4.8
NETU 4M
E52-IC20A D=4.8
NETU 8M
Standard
E52-IC35A D=4.8
1M
E52-IC35A D=4.8
2M
E52-IC35A D=4.8
4M
E52-IC35A D=4.8
8M
Heat resistive
E52-IC35A D=4.8
NETU 1M
E52-IC35A D=4.8
NETU 2M
E52-IC35A D=4.8
NETU 4M
E52-IC35A D=4.8
NETU 8M
Standard
E52-IC50A D=4.8
1M
E52-IC50A D=4.8
2M
E52-IC50A D=4.8
4M
E52-IC50A D=4.8
8M
Heat resistive
E52-IC50A D=4.8
NETU 1M
E52-IC50A D=4.8
NETU 2M
E52-IC50A D=4.8
NETU 4M
E52-IC50A D=4.8
NETU 8M
Standard
E52-IC20A D=6.4
1M
E52-IC20A D=6.4
2M
E52-IC20A D=6.4
4M
E52-IC20A D=6.4
8M
Heat resistive
E52-IC20A D=6.4
NETU 1M
E52-IC20A D=6.4
NETU 2M
E52-IC20A D=6.4
NETU 4M
E52-IC20A D=6.4
NETU 8M
Standard
E52-IC35A D=6.4
1M
E52-IC35A D=6.4
2M
E52-IC35A D=6.4
4M
E52-IC35A D=6.4
8M
Heat resistive
E52-IC35A D=6.4
NETU 1M
E52-IC35A D=6.4
NETU 2M
E52-IC35A D=6.4
NETU 4M
E52-IC35A D=6.4
NETU 8M
Standard
E52-IC50A D=6.4
1M
E52-IC50A D=6.4
2M
E52-IC50A D=6.4
4M
E52-IC50A D=6.4
8M
Heat resistive
E52-IC50A D=6.4
NETU 1M
E52-IC50A D=6.4
NETU 2M
E52-IC50A D=6.4
NETU 4M
E52-IC50A D=6.4
NETU 8M
Standard
E52-IC20A D=8
1M
E52-IC20A D=8
2M
E52-IC20A D=8
4M
E52-IC20A D=8
8M
Heat resistive
E52-IC20A D=8
NETU 1M
E52-IC20A D=8
NETU 2M
E52-IC20A D=8
NETU 4M
E52-IC20A D=8
NETU 8M
Standard
E52-IC35A D=8
1M
E52-IC35A D=8
2M
E52-IC35A D=8
4M
E52-IC35A D=8
8M
Heat resistive
E52-IC35A D=8
NETU 1M
E52-IC35A D=8
NETU 2M
E52-IC35A D=8
NETU 4M
E52-IC35A D=8
NETU 8M
Standard
E52-IC50A D=8
1M
E52-IC50A D=8
2M
E52-IC50A D=8
4M
E52-IC50A D=8
8M
Heat resistive
E52-IC50A D=8
NETU 1M
E52-IC50A D=8
NETU 2M
E52-IC50A D=8
NETU 4M
E52-IC50A D=8
NETU 8M
Exposed-terminal Models
E52-CA@B
E52-IC@B
Dimensions
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters.
Aluminum die-cast terminal box
22 dia
SUS316 sheath
+
45
Element wire
K (CA) SUS316
J (IC) SUS316
3.2 dia.
750C
650C
4.8 dia.
800C
750C
6.4 dia.
800C
750C
8.0 dia.
900C
750C
16
Two, M3
40
16
L
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page F-17 for details.
Element type Terminal type
Protective
tubing length
L (cm)
4.8 dia.
6.4 dia.
8 dia.
Model
K (CA)
Exposed-terminal Models
J (IC)
Exposed-terminal Models
20
E52-CA20B D=3.2
E52-CA20B D=4.8
E52-CA20B D=6.4
---
35
E52-CA35B D=3.2
E52-CA35B D=4.8
E52-CA35B D=6.4
E52-CA35B D=8
50
E52-CA50B D=3.2
E52-CA50B D=4.8
E52-CA50B D=6.4
E52-CA50B D=8
75
---
E52-CA75B D=4.8
E52-CA75B D=6.4
E52-CA75B D=8
20
E52-IC20B D=3.2
E52-IC20B D=4.8
E52-IC20B D=6.4
---
35
E52-IC35B D=3.2
E52-IC35B D=4.8
E52-IC35B D=6.4
E52-IC35B D=8
50
E52-IC50B D=3.2
E52-IC50B D=4.8
E52-IC50B D=6.4
E52-IC50B D=8
75
---
E52-IC75B D=4.8
E52-IC75B D=6.4
E52-IC75B D=8
Enclosed-terminal Models
E52-CA@C
E52-IC@C
Dimensions
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters.
34 dia.
57
14 dia.
SUS316 sheath
D
65
Aluminum die-cast
terminal box
Cap
35
G3/8, 19 mm between facing sides,
10 inner dia. (with 7-inner-dia.
rubber bushing built-in)
Element wire
K (CA) SUS316
J (IC) SUS316
3.2 dia.
750C
650C
4.8 dia.
800C
750C
6.4 dia.
800C
750C
8.0 dia.
900C
750C
4
16
19
L-40
Use wiring terminals that fit M3 screws.
Temperature Sensor
E52
F-13
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page F-17 for details.
Element type Terminal type
Protective
tubing length
L (cm)
4.8 dia.
6.4 dia.
8 dia.
Model
K (CA)
Enclosed-terminal Models
J (IC)
Enclosed-terminal Models
20
E52-CA20C D=3.2
E52-CA20C D=4.8
E52-CA20C D=6.4
---
35
E52-CA35C D=3.2
E52-CA35C D=4.8
E52-CA35C D=6.4
E52-CA35C D=8
50
E52-CA50C D=3.2
E52-CA50C D=4.8
E52-CA50C D=6.4
E52-CA50C D=8
75
---
E52-CA75C D=4.8
E52-CA75C D=6.4
E52-CA75C D=8
20
E52-IC20C D=3.2
E52-IC20C D=4.8
E52-IC20C D=6.4
---
35
E52-IC35C D=3.2
E52-IC35C D=4.8
E52-IC35C D=6.4
E52-IC35C D=8
50
E52-IC50C D=3.2
E52-IC50C D=4.8
E52-IC50C D=6.4
E52-IC50C D=8
75
---
E52-IC75C D=4.8
E52-IC75C D=6.4
E52-IC75C D=8
Standard Thermocouples
Specifications
Element wire
K (CA), J(IC), R
Class
750C
450C
K (CA) SUS316
12 dia.
850C
500C
J (IC)
15 dia.
850C
550C
22 dia.
900C
600C
SUS316
Non-grounded type
D
Element wire
R
17 dia.
Exposed-terminal Models
E52-CA@B
E52-IC@B
Dimensions
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters.
Aluminum die-cast terminal box
50
SUS316 protective tubing
10
+
70
22 dia.
Two, M3
26
Element wire
K (CA) SUS316
J (IC) SUS316
10 dia.
750C
450C
12 dia.
850C
500C
15 dia.
850C
550C
22 dia.
900C
600C
F-14
J (IC) SUS316
10 dia.
Element wire
K (CA) SUS316
0C to 1,400C
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page F-17 for details
Element type Terminal type
Protective
tubing length
L (cm)
12 dia.
15 dia.
22 dia.
Model
K (CA)
J (IC)
Exposed-terminal Models
Exposed-terminal Models
35
E52-CA35B D=10
E52-CA35B D=12
E52-CA35B D=15
---
50
E52-CA50B D=10
E52-CA50B D=12
E52-CA50B D=15
E52-CA50B D=22
75
E52-CA75B D=10
E52-CA75B D=12
E52-CA75B D=15
E52-CA75B D=22
100
E52-CA100B D=10
E52-CA100B D=12
E52-CA100B D=15
E52-CA100B D=22
35
E52-IC35B D=10
E52-IC35B D=12
E52-IC35B D=15
---
50
E52-IC50B D=10
E52-IC50B D=12
E52-IC50B D=15
E52-IC50B D=22
75
E52-IC75B D=10
E52-IC75B D=12
E52-IC75B D=15
E52-IC75B D=22
100
E52-IC100B D=10
E52-IC100B D=12
E52-IC100B D=15
E52-IC100B D=22
Enclosed-terminal Models
E52-CA@C
E52-IC@C
Dimensions
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters.
Aluminum die-cast terminal box
98
22 dia.
90
Element wire
K (CA) SUS316
J (IC) SUS316
10 dia.
750C
450C
12 dia.
850C
500C
15 dia.
850C
550C
22 dia.
900C
600C
40 dia.
Cap
57
L-50
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page F-17 for details
Element type Terminal type
Protective
tubing length
L (cm)
12 dia.
15 dia.
22 dia.
Model
K (CA)
J (IC)
Enclosed-terminal Models
Enclosed-terminal Models
35
E52-CA35C D=10
E52-CA35C D=12
E52-CA35C D=15
---
50
E52-CA50C D=10
E52-CA50C D=12
E52-CA50C D=15
E52-CA50C D=22
75
E52-CA75C D=10
E52-CA75C D=12
E52-CA75C D=15
E52-CA75C D=22
100
E52-CA100C D=10
E52-CA100C D=12
E52-CA100C D=15
E52-CA100C D=22
35
E52-IC35C D=10
E52-IC35C D=12
E52-IC35C D=15
---
50
E52-IC50C D=10
E52-IC50C D=12
E52-IC50C D=15
E52-IC50C D=22
75
E52-IC75C D=10
E52-IC75C D=12
E52-IC75C D=15
E52-IC75C D=22
100
E52-IC100C D=10
E52-IC100C D=12
E52-IC100C D=15
E52-IC100C D=22
Temperature Sensor
E52
F-15
Element wire
R
17 dia.
90
Bending of protective
tubing: 6 mm max.
21.7 dia.
40 dia.
Cap
57
100
L-150
Model Information
Element
type
Terminal
type
Protective
tubing
length L
(cm)
Protective tubing
diameter D (mm)
17 dia.
Model
R (See
note 1.)
Enclosed-ter- 50
minal Models 75
100
R (See
note 2.)
Enclosed-ter- 50
minal Models 75
100
Standard
Protective tubing
material
Permissible
temperature in dry
air
Note 1:
JIS ceramic Cat.1
(PT1)
Mullite, high
alumina, etc.
Note 2.
JIS special ceramic
(PT0)
Recrystallized
alumina, fused
alumina, etc.
F-16
17 dia.
0C to 1,400C
Thermocouples
E52-@@@ D=@@@M@
1 2 3
5 6
1. Element type
CA: K
IC: J
PR: R
2. Protective tubing length (L)
Specify the length in centimeters in the following range: Unit (cm)
1
1.6
3.2
4.8
6.4
8
Sheathed
SUS316
1.6 mm
Sheathed
SUS316
3.2
3.2 mm
Sheathed
SUS316
4.8
4.8 mm
Sheathed
SUS316
2 to 200
6.4
6.4 mm
Sheathed
SUS316, Inconel
3 to 500
8 mm
Sheathed
SUS316, Inconel
5 to 2,000
10
10 mm
Standard
SUS316, SUS310S
8 to 2,300
12
12 mm
Standard
SUS316, SUS310S
10 to 1,200
15
15 mm
Standard
SUS316, SUS310S
12 to 1,000
22
22 mm
Standard
SUS316, SUS310S
17
17 mm
Standard
PT1, PT0
Length (L)
Length (L)
11 to 2,000
4.8
14 to 2,300
6.4
16 to 1,200
8.0
18 to 1,000
10
21 to 126
12
24 to 126
15
29 to 156
22
39 to 206
E52-PR@C
17
Protective tubing
material
1 mm
3.2
Diameter (D)
1.6
Code
1
4. Diameter
Specify the protective tubing material according to the table.
5. Heat resistance
Specify this item for the exposed-lead models only.
Code
Temperature range
Lead type
---
20C to 70C
Sleeve: 0C to 70C
Vinyl-covered
NETU
0C to 150C
Sleeve: 0C to 100C
Length (L)
Code
3. Terminal
A: Exposed lead wires (element type: K, J)
B: Exposed terminals (element type: K, J)
C: Enclosed terminals (element type: K, J, R)
Note: Lead wires without crimped terminals (Y) are also available.
Protective tubing
material
Element type
---
SUS316
Inconel
Inconel
K, J
K, D = 6.4 to 8
SUS310S
SUS310S
K, D = 10 to 22
PT1
PT0
Examples
Element: K; protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m
E52-CA42A D=4.8 NETU 10M
Element: J; protective tubing length: 360 mm, enclosed terminals, protective tubing dia.: 3.2
E52-IC36C D=3.2
Temperature Sensor
E52
F-17
Low-cost Models
Low-cost Platinum Resistance Thermometers
Exposed-lead Models with Screws
Specifications
E52-P6D
Element type
Pt100
Conductor type
3-conductor system
Class
Class B
SUS304
Sensor length
30 mm
Dimensions
4 dia.
White (B)
50C to 250C
Lead wire
50C to 150C
Fluoroplastic-covered wire
with 1.0 outer dia. each
(PFA) 7/0.18
Red (A)
14
30
10 6
65
Y-type crimp
terminal for M4
M
15
White (B)
Model
E52-P6D 1M
E52-P6D 2M
E52-P6D 4M
E52-P6F
Element wire
Pt100
Conductor type
3-conductor system
Class
Class B
SUS304
Sensor length
30 mm
Dimensions
Flange
120
SUS304
White (B)
50C to 250C
Lead wire
50C to 150C
20 dia.
30 dia.
65
Silver
soldering Y-type crimp
terminal for M4
30
M
15
White (B)
Model
E52-P6F 1M
E52-P6F 2M
E52-P6F 4M
Exposed-lead Models
Specifications
E52-P10AE
Element type
Pt100
Conductor type
3-conductor system
Class
Class B
SUS304
Sensor length
20 mm
Dimensions
3.2 0.1 dia. SUS304 (t0.25)
Silicone
shrinkable tubing
White (B)
50C to 250C
Lead wire
50C to 150C
F-18
30
100
Y-type crimp
terminal for M4
M
White (B)
Model
E52-P10AE 1M
E52-P10AE 2M
E52-P10AE 4M
Low-cost Thermocouples
Exposed-lead Models with Spring
E52-CA@AS, E52-IC@AS
Specifications
Dimensions
Element type
K (CA), J (IC)
Element dia.
Class
Class 2 (0.75)
Protective tubing
material
SUS304
Thermal contact
Non-grounded type
Temperature range
0C to 400C: K (CA)
0C to 350C: J (IC)
Lead wire
0C to 180C
32
L
SUS304 (t0.4)
4.8 dia.
12 dia.
M
150
80
Red (+)
Sleeve
Brass-nickel Closely wound
plating
spring coil
Fully glass-wool-covered
compensating cable with
four 0.65-dia. conductors
and external dimensions
of approx. 5.1 3.0
White ()
Y-type crimp
terminal for M4
Color code
(K: Blue, J: Yellow)
65
100
150
200
E52-CA6AS 1M
E52-IC6AS 1M
E52-CA6AS 2M
E52-IC6AS 2M
E52-CA6AS 4M
E52-IC6AS 4M
E52-CA10AS 1M
E52-IC10AS 1M
E52-CA10AS 2M
E52-IC10AS 2M
E52-CA10AS 4M
E52-IC10AS 4M
E52-CA15AS 1M
E52-IC15AS 1M
E52-CA15AS 2M
E52-IC15AS 2M
E52-CA15AS 4M
E52-IC15AS 4M
E52-CA20AS 1M
E52-IC20AS 1M
E52-CA20AS 2M
E52-IC20AS 2M
E52-CA20AS 4M
E52-IC20AS 4M
Temperature Sensor
E52
F-19
Specifications
Dimensions
Element type
K (CA), J (IC)
Element dia.
Class
Class 2 (0.75)
Protective tubing
material
SUS304
Thermal contact
Grounded type
Temperature range
0C to 400C: K (CA)
0C to 350C: J (IC)
Lead wire
0C to 180C
0.65-dia.
2.8
thermocouple
element
10
M
Color tubing
Brass (K: Blue,
J: Yellow)
80
Red (+)
B 3.8 dia.
Movable ring
(brass)
White ()
Color code
5 dia.
(K: Blue,
SUS304
Crimp terminal for M4
J: Yellow)
screw
(W1/4) Enamel-bonded
Covered with black insulation tubing
copper wire
Fully glass-wool-covered cable
with external shield and
external dimensions of approx.
3.1 2.0
Lead wire
length (m)
Screw
M1/4
M6
M8
A (mm)
5.3
B (mm)
11.5
11
14
C (mm)
2.5
Installation Example
Cut a thread into the workpiece, and screw in the
thermocouple while pushing in so that the tip
makes complete contact.
End
M6
Brass pipe
Screw
Workpiece
Note: E52-CA1D with the same shape and multiple element wires are also available.
Refer to page F-29 for details.
Protective tubing length (mm)
M6 screw
M8 screw
W1/4 screw
F-20
E52-CA1D M6 1M
E52-IC1D M6 1M
E52-CA1D M6 2M
E52-IC1D M6 2M
E52-CA1D M6 4M
E52-IC1D M6 4M
E52-CA1D M8 1M
E52-IC1D M8 1M
E52-CA1D M8 2M
E52-IC1D M8 2M
E52-CA1D M8 4M
E52-IC1D M8 4M
E52-CA1D W1/4 1M
E52-IC1D W1/4 1M
E52-CA1D W1/4 2M
E52-IC1D W1/4 2M
E52-CA1D W1/4 4M
E52-IC1D W1/4 4M
E52-CA6F, E52-IC6F
Dimensions
Element type
K (CA), J (IC)
Element diameter
Class
Class 2 (0.75)
SUS304
Thermal contact
Grounded type
Temperature range
0C to 350C: K (CA)
0C to 350C: J (IC)
Lead wire
0C to 150C
Fully glass-wool-covered
tubing with external
dimensions of 3.6 2.2
120
120
Solder processed
Red (+)
Color code
(K: Blue,
J: Yellow)
M
4 dia.
20 dia.
30 dia.
1
65
30
15
White ()
80 10
Model
E52-CA6F 1M
E52-IC6F 1M
E52-CA6F 2M
E52-IC6F 2M
E52-CA6F 4M
E52-IC6F 4M
K (CA), J (IC)
Element diameter
Class
Class 2 (0.75)
SUS304
Thermal contact
Grounded type
Temperature range
0C to 350C: K (CA)
0C to 350C: J (IC)
Lead wire
0C to 150C
E52-CA6D, E52-IC6D
Dimensions
Fully glass-wool-covered
Tapered
pipe thread tubing with external
dimensions of 3.6 2.2
Argon arc welding SUS304
Solder processed
R1/8
SUS304
Silicone tubing
Red stripe (+)
Blue stripe ()
4 dia.
14
10 6
65
80 10
30
15
M
Color code (K: Blue, J: Yellow)
Model
E52-CA6D 1M
E52-IC6D 1M
E52-CA6D 2M
E52-IC6D 2M
E52-CA6D 4M
E52-IC6D 4M
Temperature Sensor
E52
F-21
Exposed-lead Models
Specifications
E52-CA10AE, E52-IC10AE
Element type
K (CA), J (IC)
Element diameter
Class
Class 2 (0.75)
SUS304
Thermal contact
Non-grounded type
Temperature range
0C to 350C: K (CA)
0C to 200C: J (IC)
Dimensions
3.2 0.1 dia.
Caulking
2.8-max. outer-dia.
fully glass-woolcovered tubing
Red (+)
White ()
80
M
100
0C to 180C
Lead wire
SUS304
Model
E52-CA10AE 1M
E52-IC10AE 1M
E52-CA10AE 2M
E52-IC10AE 2M
E52-CA10AE 4M
E52-IC10AE 4M
Exclusive Models
Thermocouples
Thermocouples for Molding Machines
Specifications
E52-CA2GV, E52-IC2GV
Element type
K (CA), J (IC)
Element diameter
Class
Class 2 (0.75)
Protective tubing
material
SUS304
Thermal contact
Grounded type
Temperature range
0C to 350C
Lead wire
0C to 180C
Dimensions
Bayonet
4.8 dia. SUS304
6.8 dia.
M3 screw
Adapter (provided)
R1/8
4.1-outer-dia. glass-wool-covered
cable with external shield
Red (+)
12 dia.
White ()
25
15
22
105
Color code
Y-type crimp
(K: Blue, J: Yellow) terminal for M4
10
15
25
Brass-nickel plating
M
Lead wire length (M): 1 or 2 m
Lead wire
length (m)
F-22
Model
E52-CA2GV 1M
E52-IC2GV 1M
E52-CA2GV 2M
E52-IC2GV 2M
E52-CA1GT, E52-IC1GT
Element type
K (CA), J (IC)
Element diameter
Class
Class 2 (0.75)
Thermal contact
Grounded type
Temperature range
0C to 300C
Lead wire
0C to 150C
Dimensions
4.2-max. outer-dia. glass-woolcovered cable with externally
braided shield
4.4 dia.
15
(+) red
6 dia. max.
() white
Color code
(K: Blue, J: Yellow)
80
M
Lead wire length (M): 1 or 2 m
Y-type crimp
terminal for M4
Model
E52-CA1GT 1M
E52-IC1GT 1M
E52-CA1GT 2M
E52-IC1GT 2M
E52-P2GS
Element type
Pt100
Class
Class B
SUS304
With brass-nickel-plated bracket
Conductor type
3-conductor system
Temperature range
50C to 250C
Lead wire
Dimensions
Silicone-covered 3-conductor cable
Brass-nickel-plated bracket with twelve 0.18-dia. conductors (0.3-mm thick)
Four, 3.2 dia.
6-dia. SUS304
and approx. 4.8 dia.
sleeve
Press
Red (A)
20
14
White (B)
5
50
50C to 150C
20
28
Silicone tubing
M
Approx. 32
Black (B)
80
Y-type crimp
terminal for M4
Lead wire length (M): 1 or 2 m
6
1.5
Model
E52-P2GS 1M
E52-P2GS 2M
Temperature Sensor
E52
F-23
E52-P10GR
Element type
Pt100
Class
Class B
Protective tubing
material
SUS304
Conductor type
3-conductor system
Dimensions
15
92
SUS304 8 dia.
White (B)
78 20 dia.
20C to 70C
Lead wire
Red (A)
Black (B)
Y-type crimp
terminal for M4
80
97
100
2,000
55
Brass-nickel-plated
protective pipe
7 dia.
PF1/2
Model
E52-P10GR 2M
E52-P20GW
Element type
Pt100
Class
Class B
Protective tubing
material
SUS304
Polyamide-insulated tubing
with 0.5-dia. Ag lead wire
Conductor type
Resistance
thermometer
element
Temperature range
50C to 250C
Lead wire
20C to 70C
Dimensions
Round press with
hexagonal caulking
Red (A1)
Black (B1)
White (B1)
Yellow (B2)
PFA tubing
Green (B2)
200
70
80
Note: The protective tubing is of pipe construction, which must not be bent.
Lead wire length (m)
F-24
Model
E52-P20GW 1M
E52-P20GW 2M
E52-P10GP
Element wire
Pt100
Class
Class B
SUS304
Conductor type
3-conductor system
Temperature range
0C to 70C (underwater)
20C to 70C (in the air)
Lead wire
0C to 70C
Resistive pressure
Dimensions
7.6-outer-dia. vinyl-covered 3conductor cable (thirty 0.18-dia.
conductors, 0.75 mm thick)
Y-type crimp
terminal for M4
Red (A)
20 dia. 7 dia.
White (B)
Black (B)
100
10 kg/cm 2 max.
62
Model
E52-P10GP 2M
E52-P10GP 4M
E52-CA20A-1
Element type
K (CA)
Class
Class 2 (0.75)
Protective tubing
material
Thermal contact
Non-grounded type
Temperature range
0C to 180C
Lead wire
Vinyl-covered: 20C
to 70C
Dimensions
Red (+)
Y-type crimp
Araldite resin
terminal for M4
Compensating
conductor
Sleeve
Sheath
D
White ()
FEP-covered tubing
2,000
Model
200
40
Protective
Covering
tubing diameter thickness (mm)
Lead wire
length (m)
E52-CA20A-1 D=4.6 2M
D = 4.6
0.7
E52-CA20A-1 D=6 2M
D = 6.0
0.6
E52-CA20A-1 D=8 2M
D = 8.0
0.8
Temperature Sensor
E52
F-25
Platinum Measurement
Exposed-lead Models
Specifications
E52-P20A-1
Element type
Pt100
Class
Class B
Protective tubing
material
Red (A)
Conductor type
3-conductor system
White (B)
Temperature range
80C to 180C
Black (B)
Lead wire
Vinyl-covered: 20C
to 70C
Dimensions
Y-type crimp
terminal for M4
Araldite resin
Lead wires
Sheath
D
FEP-covered tubing
2,000
Model
200
60
Protective
Coating
tubing diameter thickness (mm)
Lead wire
length (m)
E52-P20A-1 D=4.6 2M
D = 4.6
0.7
E52-P20A-1 D=6 2M
D = 6.0
0.6
E52-P20A-1 D=8 2M
D = 8.0
0.8
E52-P5A-40
Element type
Pt100
Class
Class B
Protective tubing
material
PFA-molded (FEP)
covering
Conductor type
3-conductor system
Temperature range
50C to 180C
Lead wire
PFA-covered (PFA):
50C to 180C
Dimensions
FEP mold
7 dia.
Red (A)
White (B)
10
7
White (B)
40
Y-type crimp
terminal for M4
65
M
Model
F-26
Lead wire
length (m)
E52-P5A-40 2M
D = 10 (elliptical)
E52-P5A-40 4M
D = 10 (elliptical)
E52-P5A-40 6M
D = 10 (elliptical)
E52-P5A-40 8M
D = 10 (elliptical)
E52-CA@@C-6
Element type
K (CA)
Class
Class 2 (0.75)
Protective tubing
material
L2 section: SUS316
L1 section: SUS304
Operating temperature
range (in dry air)
Dimensions
L
SUS316
Conduit
thread
PF1/2
Installation
method
Conforms to Technical
Recommendations of the
Research Institute of
Industrial Safety (Japan)
15 dia.
6.4 dia.
84 dia.
115
L1
L2
SUS304
18
77
Model
PF1/2
Protective tubing
length L (cm)
Protective
tubing diameter
L2 (mm)
20
D = 6.4
150
35
D = 6.4
300
50
D = 6.4
450
75
D = 6.4
700
E52-P@@C-6
Element type
Pt100
Class
Class B
Protective tubing
material
L2 section: SUS316
L1 section: SUS304
Operating temperature
range (in dry air)
Conduit
thread
PF1/2
Installation
method
Conforms to Technical
Recommendations of the
Research Institute of
Industrial Safety (Japan)
Dimensions
L
L2
115
L1
SUS316
15 dia.
6.4 dia.
84 dia.
SUS304
18
77
Model
Protective tubing
length L (cm)
PF1/2
Protective
tubing diameter
L2 (mm)
20
D = 6.4
150
35
D = 6.4
300
50
D = 6.4
450
75
D = 6.4
700
Temperature Sensor
E52
F-27
Double-element Models
Thermocouple
Exposed-lead Models
Specifications
E52-CA20A-7
Element type
K (CA)
Class
Class 2 (0.75)
Protective tubing
material
Thermal contact
Non-grounded type
Temperature range
0C to permissible
temperature limit
Lead wire
Vinyl-covered: 20C
to 70C
Dimensions
Compensating
conductor
Red (+)
Sleeve
Protective tubing
White ()
Red (+)
White ()
80
2,000
45
200
Element wire
K (CA) SUS316
3.2 dia.
750C
4.8 dia.
850C
6.4 dia.
850C
8.0 dia.
900C
Model
Protective
tubing diameter
Lead wire
length (m)
Permissible
Temperature (C)
E52-CA20A-7 D=3.2 2M
D = 3.2
750
E52-CA20A-7 D=4.8 2M
D = 4.8
800
E52-CA20A-7 D=6.4 2M
D = 6.4
800
E52-CA20A-7 D=8.0 2M
D = 8.0
900
E52-P20A-7
Element type
Pt100
Class
Class B
Protective tubing
material
Conductor type
3-conductor system
Black (B1)
Temperature range
200C to 450C
White (B1)
Lead wire
Vinyl-covered: 20C
to 70C
Dimensions
Y-type crimp
terminal for M4
Red (A1)
Lead wires
Yellow (B2)
Araldite resin
Green (B2)
Model
Brown (A2)
80
F-28
2,000
70
200
Protective
tubing diameter
Lead wire
length (m)
E52-P20A-7 D=4.8 2M
D = 4.8
E52-P20A-7 D=6.4 2M
D = 6.4
Enclosed-terminal Models
Specifications
E52-P20C-7
Element type
Pt100
Class
Class B
Protective tubing
material
Conductor type
3-conductor system
Temperature range
200C to 450C
Dimensions
98
40 dia.
80 dia.
Terminal box
Protective tubing
D
57
150
Model
Protective tubing
Protective
length L (cm)) tubing diameter
E52-P20C-7 D=4.8
20
D = 4.8
E52-P20C-7 D=6.4
20
D = 6.4
E52-CA1D-40
Element type
K (CA)
Class
Class 2 (0.75)
Screw material
SUS304
Thermal contact
Grounded type
Temperature range
0C to 300C
Lead wire
Silicone-covered (0.1/30): 0C to
150C
Dimensions
1
2.8
10
4.2
M
13
80
Silicone
covering
80
11
3.8 dia.
Thermocouple
element
wire
Movable ring
Model
Screw pitch
Lead wire
length (m)
E52-CA1D-40 M6 1M
M6
E52-CA1D-40 M6 2M
M6
E52-CA1D-40 M6 4M
M6
E52-CA1GT-14
Element type
K (CA)
Class
Class 2 (0.75)
Thermal contact
Grounded type
Temperature range
0C to 350C
Lead wire
Silicone-covered (0.1/30): 0C to
150C
Dimensions
Silicone-covered
compensating cable with
thirty 0.1-dia. conductors
and external dimensions
of 3.5 4.9
M4, round,
crimp terminal
6.5
Color tubing
Blue CA (K)
(+)
()
15
30
80
Crimp terminal
for M4
E52-CA1GT-14 1M
E52-CA1GT-14 2M
Temperature Sensor
E52
F-29
Thermistors
Element Interchangeable Thermistor for E5CS and E5C2
Temperature Ranges
Temperature
range
Color code
Nominal resistance
Thermistor
constant
50C to 50C
Blue
6 kW (0C)
3390K
0C to 100C
Black
6 kW (0C)
3390K
50C to 150C
Red
30 kW (0C)
3450K
100C to 200C
Yellow
0.55 kW (200C)
4300K
150C to 300C
Green
4 kW (200C)
5133K
Specifications
Item
E52-THE@@
Coupling method
Class
JIS class 1
SUS304
Time constant
8 to 15 s in still water
Dissipation factor
180C
Error
Detectable temperature
Error
50C to 100C
1C max.
100C to 350C
Permissible Temperature
Detectable temperature
Operating temperature
50C to 50C
100C
0C to 100C
150C
50C to 150C
200C
100C to 200C
250C
150C to 300C
350C
F-30
Lead wire
A pair of 0.12 dia. 7 PFA-insulated stranded wires with 0.86
outer dia. each
Exposed-lead Models
E52-THE5A
Dimensions
Temperature range
SUS304 t0.25
Lead wires
(See note.)
Color code
4 dia.
15
50
50 10
1,030
Model
50C to 50C
E52-THE5A 50-50C 1M
0C to 100C
E52-THE5A 0-100C 1M
50C to 150C
E52-THE5A 50-150C 1M
100C to 200C
E52-THE5A 100-200C 1M
150C to 300C
E52-THE5A 150-300C 1M
Temperature range
Dimensions
Tapered pipe thread
SUS304
Lead wires
R1/8
(See note.)
SUS304 t0.25
Color code
4 dia.
Argon arc welding
15
10 6
14
65
15
Model
50C to 50C
E52-THE6D 50-50C 1M
0C to 100C
E52-THE6D 0-100C 1M
50C to 150C
E52-THE6D 50-150C 1M
100C to 200C
E52-THE6D 100-200C 1M
150C to 300C
E52-THE6D 150-300C 1M
50 10
1,000
Temperature range
Dimensions
Three, 3.5 dia.
120
120
SUS304
Silver
soldering
SUS304 t0.25
Lead wires
(See note.)
Color code
4 dia.
15
1
20 dia.
30 dia.
65
15
Model
50C to 50C
E52-THE6F 50-50C 1M
0C to 100C
E52-THE6F 0-100C 1M
50C to 150C
E52-THE6F 50-150C 1M
100C to 200C
E52-THE6F 100-200C 1M
150C to 300C
E52-THE6F 150-300C 1M
50 10
1,000
Note: 1. The Thermistor lead cable can be extended, but do not use a standard lead wire for extension. If waterproof performance is required, be
sure that the lead cable joint is of waterproof construction as well.
2. Be sure to specify the model and temperature range when ordering the Thermistor. The Thermistor has a color code according to the
temperature range.
Temperature Sensor
E52
F-31
Accessories
Compression Fittings
Model Information
Model
Screw of part
Applicable
a
protective tubing
diameter
PT 1/8 D=1.0
R 1/8
Dimension
b
1.0 dia.
PT 1/8 D=1.6
1.6 dia.
PT 1/8 D=3.2
3.2 dia.
PT 1/8 D=4.8
Flat diameter
Part c
Part b
13
10
14
14
15
12
17
14
4.8 dia.
PT 1/4 D=3.2
R 1/4
3.2 dia.
PT 1/4 D=4.8
4.8 dia.
PT 1/4 D=6.4
6.4 dia.
PT 3/8 D=8
R 3/8
8 dia.
19
15
21
17
PT 1/2 D=10
R 1/2
10 dia.
23.5
19.5
26
21
M 12 D=4.8
M 12
4.8 dia.
15
12
17
14
Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the
sensing object will cause problems.
The compression fitting is a screw that adjusts and secures the
insertion length of Temperature Sensors with the above protective
tubing diameters.
The material of the Compression Fitting is SUS304 with internal
fixing beads made of brass.
Sensor side
Head side
Material
Main body
SUS304
Lock bead
Brass
Retaining screw
SUS304
T.P.I.
Outer
(No. of diamethreads ter: d
/inch)
Effective
diameter: d2
Root
diameter: d1
Standard
diameter
position a
(from
pipe
end)
Minimum
effective
screw
length:
f
PT 1/8
28
9.728
9.147
8.566
3.97
0.91
2.5
PT 1/4
19
13.157
12.301
11.445
6.01
1.34
3.7
PT 3/8
19
16.662
15.806
14.950
6.35
1.34
3.7
PT 1/2
14
20.955
19.793
18.631
8.16
1.81
5.0
Tapered thread
d d2
F-32
d1
Standard dia.
Loose Flanges
Model Information
Applicable protective
tubing diameter
MF-1
Model
3.2 dia.
MF-1 D=3.2
4.8 dia.
MF-1 D=4.8
6.4 dia.
MF-1 D=6.4
8 dia.
MF-1 D=8
10 dia.
MF-2 D=10
12 dia.
MF-2 D=12
15 dia.
MF-2 D=15
22 dia.
MF-2 D=22
MF-2
120
120
Three, 5 dia.
36
54 dia.
21 dia.
D dia.
M4
31 dia.
D dia.
5
M6
14
24
23 dia.
45 dia.
6.6
35 dia.
70 dia.
Material: Aluminum
Temperature Sensor
E52
F-33
Compensating Conductors
The material of the Compensating Conductor is the same as or similar to that of the Thermocouple. Therefore, the Thermocouple can be connected
to the Compensating Conductor just as if the length of the Thermocouple is to be extended. A standard model for a temperature range between
20C and 70C and two types of heat-resistive models for a temperature range between 0C and 150C are available.
Be sure to use the compensating conductor for the extension of the length of the thermocouple.
Model Information
Thermocouple
R
Heat
resistance
Standard
J (IC)
Model
(Length)
Heat resistive
K (CA)
Exterior
1m
WPRG 1M
2m
WPRG 2M
4m
8m
WPRG 4M
WPRG 8M
Fully glass-wool-covered
WPRH 1M
WPRH 2M
WPRH 4M
WPRH 8M
WPRH6 1M
WPRH6 2M
WPRH6 4M
WPRH6 8M
Standard
WCAG 1M
WCAG 2M
WCAG 4M
WCAG 8M
Heat resistive
Fully glass-wool-covered
WCAH 1M
WCAH 2M
WCAH 4M
WCAH 8M
WCAH6 1M
WCAH6 2M
WCAH6 4M
WCAH6 8M
Standard
WICG 1M
WICG 2M
WICG 4M
WICG 8M
Heat resistive
Fully glass-wool-covered
WICH 1M
WICH 2M
WICH 4M
WICH 8M
WICH6 1M
WICH6 2M
WICH6 4M
WICH6 8M
Note: 1. Compensating Conductors with lengths, increased in units of a meter, up to 100 meters are available on request. Specify lengths above
100 meters in units of 100 meters. The maximum length depends on the product. Contact your OMRON representative for details.
2. The WCAG-40 is suitable for moving parts. It has the same waterproof characteristics as the standard model (fully vinyl-covered) and
can be used at high temperatures.
WPRG
Type of
thermocouple
R
Use
Code
Standard
WPRH
K (CA)
4/0.65
0 to 70
Fully glass-woolcovered
7/0.3
0 to 150
WICG
WICH
WICH6
+3/7
Exterior
color
Black
Resistance of
both lines (/m)
0.055
0.140
VX-G
4/0.65
20 to 70
2.5
Fully glass-woolcovered
7/0.3
0 to 150
3.0
1.07
4.18
WX-H6
J (IC)
Error (C)
RX-H6
WCAH6
WCAG-40
Operating
temperature
range (C)
Standard
WCAH
Number of
wires/wire
diameter
RX-G
WPRH6
WCAG
Exterior
0.39
Silicone-covered
30/0.1
20 to 150
2.5
Standard
JX-G
4/0.65
20 to 70
2.5
Fully glass-woolcovered
7/0.3
0 to 150
JX-H6
Blue
Yellow
0.47
1.27
F-34