INTRODUCTION AND
SITE PREPARATION
CHAPTER 2
CABINET INSTALLATION
CHAPTER 3
INTEROPERABILITY
CHAPTER 4
COMMISSIONING
CHAPTER 5
DECOMMISSIONING
INDEX
GMR-01
68P02902W97-A
68P02902W97-A
GSM
GMR-01
Manual Revision
GMR-01
68P02902W97-A
26 Sep 2003
Motorola manual
affected
Incorporate this GMR only in the manual number and version listed below:
68P02902W97-A
Problem reports
This revision provides a fix to the following problem reports:
No new Service Requests fixed in this revision.
Reason for
revision
This revision provides additional and updated information as follows:
Chap. 1:
Page 1-8: Table 1-5 revised current supply figures corrected. Table 1-6
revised cabinet power consumption figures updated and PSU output
figures added. Battery backup section moved here from page 1-10.
Page 1-9: Thermal dissipation section deleted. Minor change to Table 1-8.
Note added to clarify measurement point for RF output power.
Page 1-10: Sensitivity section rewritten.
Chap. 2:
68P02902W97-A
GMR-01
GMR Page 1
GSM
Chap.3:
Page 3-4: Note deleted (replaced by new section on page 3-20). New
section added to define requirements for connecting Horizonmacro or
M-Cell6 cabinets to Horizon II macro.
Page 3-19: CTU2 compatibility clarified.
Page 3-20: Figure 3-20 modified to refer to Horizonmacro indoor only.
Section added to explain restrictions when CTUs replaced by CTU2s in
Horizonmacro indoor cabinets.
Action
Remove and replace pages in the Manual as follows:
Remove
Insert
Obsolete pages
Destroy all obsolete pages. Do not destroy this page.
Completion
On completion of the Manual Revision, insert this Manual Revision sheet in the
front or back of the manual, for future reference.
GMR Page 2
GMR-01
26 Sep 2003
GSM
68P02902W97-A
GMR-01
GSM
Restrictions
The software described in this document is the property of Motorola. It is furnished under a license
agreement and may be used and/or disclosed only in accordance with the terms of the agreement.
Software and documentation are copyright materials. Making unauthorized copies is prohibited by
law. No part of the software or documentation may be reproduced, transmitted, transcribed, stored
in a retrieval system, or translated into any language or computer language, in any form or by any
means, without prior written permission of Motorola.
Accuracy
While reasonable efforts have been made to assure the accuracy of this document, Motorola
assumes no liability resulting from any inaccuracies or omissions in this document, or from the use
of the information obtained herein. Motorola reserves the right to make changes to any products
described herein to improve reliability, function, or design, and reserves the right to revise this
document and to make changes from time to time in content hereof with no obligation to notify any
person of revisions or changes. Motorola does not assume any liability arising out of the application
or use of any product or circuit described herein; neither does it convey license under its patent
rights of others.
Trademarks
.
.
.
ii
GMR-01
26 Sep 2003
GSM
Contents
Issue status of this manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
General cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
12
13
GMR amendment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
17
18
Chapter 1
Introduction and site preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
11
Introduction to installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Manual scope . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safety instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
13
13
13
14
14
Preparation overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview of site preparation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Pre-installation procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
16
16
16
17
17
17
17
17
18
18
19
110
110
111
111
111
112
113
113
114
114
114
114
114
115
115
115
68P02902W97-A
GMR-01
iii
GSM
iv
116
116
116
116
116
116
Chapter 2
Horizon II macro cabinet installation . . . . . . . . . . . . . . . . . . . . . . . . . . . .
21
Installation overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction to installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installation sections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Horizon II macro cabinet components . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
E1/T1 line testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Equipment delivery and unpacking . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Delivery and packaging overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Packaging crate . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Equipment module packaging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unpacking the crate, plinth and cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . .
Safe disposal of packing material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
CTU2 allotted slot retention . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Installing the cabinet plinth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview of plinth installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Recommended bolt length for concrete floor . . . . . . . . . . . . . . . . . . . . . . .
Installing the plinth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting the cabinet on the plinth . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Methods of plinth use . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fitting a hood or stacking bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Introduction to fitting a hood or stacking bracket . . . . . . . . . . . . . . . . . . . .
Diagram of pin location points on cabinet top . . . . . . . . . . . . . . . . . . . . . . .
Fitting an optional hood . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fitting a stacking bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fitting the stacking bracket front cover . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mounting a second cabinet onto the stacking bracket . . . . . . . . . . . . . . . . . . . . .
Overview of stacked cabinet fit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Eyebolt locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Eyebolt positions and safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fitting upper cabinet onto the stacking bracket . . . . . . . . . . . . . . . . . . . . .
Completed stacked cabinet assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Earthing and transient protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Site earthing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Transient and lightning protection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connections to RF modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview of RF connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Types of RF connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
SURF2/Tx block interconnecting cables . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unused SMA connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RF connector torque settings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RF connection principles . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rx/Tx single antenna duplexing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
23
23
24
25
25
26
26
26
26
27
28
28
29
29
29
210
211
211
211
212
212
212
213
214
215
216
216
216
217
218
219
220
220
220
221
221
222
222
222
222
223
224
GMR-01
26 Sep 2003
GSM
Suggested RF configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview of configuration diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration for omni 1 or 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration for omni 2 or 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration for omni 2 or 4 with HCU . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration for omni 3 or 6 with HCU . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration for omni 3 or 6 with DHU . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration for omni 4 or 8 with HCU . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration for omni 6 or 12 with DHU . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration for 2 cabinet, omni 8 or 16 with HCU and DHU . . . . . . . . .
Configuration for sector 1/1 or 2/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration for sector 2/2 or 4/4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration for sector 2/2 or 4/4 with HCU . . . . . . . . . . . . . . . . . . . . . . . .
Configuration for sector 3/3 or 6/6 with HCU . . . . . . . . . . . . . . . . . . . . . . . .
Configuration for sector 3/3 or 6/6 with DHU . . . . . . . . . . . . . . . . . . . . . . . .
Configuration for 2 cabinet, sector 4/4 or 8/8 with HCU . . . . . . . . . . . . . .
Configuration for 2 cabinet, sector 6/6 or 12/12 with DHU . . . . . . . . . . . .
Configuration for 4 cabinet, sector 8/8 with HCU and DHU . . . . . . . . . . .
Configuration for sector 1/1/1 or 2/2/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration for sector 2/2/2 or 4/4/4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Configuration for sector 2/2/2 or 4/4/4 with HCU . . . . . . . . . . . . . . . . . . . .
Configuration for 2 cabinet, sector 3/3/3 or 6/6/6 with HCU . . . . . . . . . . .
Configuration for 2 cabinet, sector 3/3/3 or 6/6/6 with DHU . . . . . . . . . . .
Configuration for 2 cabinet, sector 4/4/4 or 8/8/8 with HCU . . . . . . . . . . .
Configuration for 3 cabinet, sector 6/6/6 with DHU . . . . . . . . . . . . . . . . . .
Configuration for 4 cabinet, sector 8/8/8 with HCU and DHU . . . . . . . . . .
Configuration for sector 2/2/2 or 4/4/4, 4 branch Rx diversity . . . . . . . . .
225
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
243
244
245
246
247
248
249
251
253
254
254
255
255
256
257
258
260
260
260
263
GPS connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GPS connector location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
GPS connector pinouts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
264
264
264
265
265
265
266
267
267
268
269
68P02902W97-A
GMR-01
GSM
vi
270
270
270
271
Chapter 3
Horizon II macro interoperability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
31
Introduction to interoperability . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Mixed product sites . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Architectural constraints . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
33
33
33
34
34
34
37
37
37
39
312
312
313
319
321
Chapter 4
Commissioning the Horizon II macro . . . . . . . . . . . . . . . . . . . . . . . . . . .
41
43
43
43
44
Pre-power up checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview of pre-power up checks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Visual inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Request for power supply connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Earth continuity check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
AC power system insulation check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
45
45
46
46
47
47
48
48
48
410
412
Cabinet shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Shutdown procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
413
413
414
416
GMR-01
26 Sep 2003
GSM
Chapter 5
Decommissioning the Horizon II macro . . . . . . . . . . . . . . . . . . . . . . . . .
51
53
53
53
53
53
54
55
56
57
58
59
59
510
Index . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
I1
68P02902W97-A
GMR-01
vii
GSM
List of Figures
viii
113
25
26
29
211
212
213
214
215
216
219
221
223
226
Figure 2-14 Single cabinet, omni 2 or 4 with DUP and air combining . . . . . . . .
227
228
Figure 2-16 Single cabinet, omni 3 or 6 with DUP, HCU and air combining . . .
229
230
Figure 2-18 Single cabinet, omni 4 or 8 with DUP, HCU and air combining . . .
231
232
Figure 2-20 Two cabinets, omni 8 or 16 with DUP, HCU, DHU and
air combining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
233
234
Figure 2-22 Single cabinet, sector 2/2 or 4/4 with DUP and air combining . . .
235
Figure 2-23 Single cabinet, sector 2/2 or 4/4 with DUP and HCU . . . . . . . . . . .
236
Figure 2-24 Single cabinet, sector 3/3 or 6/6 with DUP, HCU and
air combining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
237
Figure 2-25 Single cabinet, sector 3/3 or 6/6 with DUP and DHU . . . . . . . . . . .
238
Figure 2-26 Two cabinets, sector 4/4 or 8/8 with DUP, HCU and
air combining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
239
Figure 2-27 Two cabinets, sector 6/6 or 12/12 with DUP, DHU and
air combining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
240
Figure 2-28 Four cabinets, sector 8/8 with DUP, HCU, DHU and air combining
(Part A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
241
Figure 2-29 Four cabinets, sector 8/8 with DUP, HCU, DHU and air combining
(Part B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
242
243
Figure 2-31 Single cabinet, sector 2/2/2 or 4/4/4 with DUP and air combining
244
GMR-01
26 Sep 2003
GSM
Figure 2-32 Single cabinet, sector 2/2/2 or 4/4/4 with DUP and HCU . . . . . . .
245
Figure 2-33 Two cabinets, sector 3/3/3 or 6/6/6 with DUP, HCU and
air combining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
246
Figure 2-34 Two cabinets, sector 3/3/3 or 6/6/6 with DUP and DHU . . . . . . . .
247
Figure 2-35 Two cabinets, sector 4/4/4 or 8/8/8 with DUP, HCU and
air combining . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
248
Figure 2-36 Three cabinets, sector 6/6/6 with DUP, DHU and air combining
(Part A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
249
Figure 2-37 Three cabinets, sector 6/6/6 with DUP, DHU and air combining
(Part B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
250
Figure 2-38 Four cabinets, sector 8/8/8 with DUP, HCU, DHU and air combining
(Part A) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
251
Figure 2-39 Four cabinets, sector 8/8/8 with DUP, HCU, DHU and air combining
(Part B) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
252
Figure 2-40 Single cabinet, sector 2/2/2 or 4/4/4 with DUP and
air combining and 4 branch Rx diversity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
253
254
256
257
261
262
264
266
268
269
35
36
37
38
39
310
310
311
313
314
315
316
317
68P02902W97-A
GMR-01
ix
GSM
318
319
320
Figure 3-17 Special cable gland plate required for mixed M-Cell6 and
Horizon installations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
321
Figure 3-18 Location of the snap-in multi cable gland and mounting plate
in the M-Cell6 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
321
43
Figure 4-2 Cabinet showing power up modules and detailed view of CBC . . .
412
57
58
GMR-01
26 Sep 2003
GSM
List of Tables
Table 1-1 Horizon II macro tool list . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14
16
17
17
18
18
19
19
110
111
111
Table 1-12 Torque values for all cabinet screws/bolts and RF connectors . . .
111
112
24
222
222
255
256
257
258
259
260
264
33
312
44
47
510
68P02902W97-A
GMR-01
xi
GSM
xii
GMR-01
26 Sep 2003
GSM
Version information
The following table lists the versions of this manual in order of manual issue:
Manual
issue
A
Date of
issue
Remarks
GMR
Number
N/A
N/A
Remarks
68P02902W97-A
GMR-01
General information
GSM
General information
Important notice
If this manual was obtained when attending a Motorola training course, it will not
be updated or amended by Motorola. It is intended for TRAINING PURPOSES
ONLY. If it was supplied under normal operational circumstances, to support a
major software release, then corrections will be supplied automatically by
Motorola in the form of General Manual Revisions (GMRs).
Purpose
Motorola cellular communications manuals are intended to instruct and assist
personnel in the operation, installation and maintenance of the Motorola cellular
infrastructure equipment and ancillary devices. It is recommended that all
personnel engaged in such activities be properly trained by Motorola.
WARNING
These manuals are not intended to replace the system and equipment training
offered by Motorola, although they can be used to supplement and enhance the
knowledge gained through such training.
GMR-01
26 Sep 2003
General information
GSM
Feature references
Most of the manuals in the set, of which this manual is part, are revised to
accommodate features released at Motorola General System Releases (GSRn)
or GPRS Support Node (GSNn) releases. In these manuals, new and amended
features are tagged to help users to assess the impact on installed networks.
The tags are the appropriate Motorola Roadmap DataBase (RDB) numbers or
Research and Development Prioritization (RDP) numbers. The tags include
index references which are listed in the manual Index. The Index includes the
entry feature which is followed by a list of the RDB or RDP numbers for the
released features, with page references and hot links in electronic copy.
The tags have the format: {nnnn} or {nnnnn}
Where:
is:
{nnnn}
{nnnnn}
Subheading
For a list of Roadmap numbers and the RDB or RDP numbers of the features
included in this software release, refer to the manual System Information: GSM
Overview (68P02901W01), or to the manual System Information: GPRS Overview
(68P02903W01).
68P02902W97-A
GMR-01
General information
GSM
Data encryption
In order to avoid electronic eavesdropping, data passing between certain
elements in the GSM and GPRS network is encrypted. In order to comply with
the export and import requirements of particular countries, this encryption
occurs at different levels as individually standardised, or may not be present at
all in some parts of the network in which it is normally implemented. The manual
set, of which this manual is a part, covers encryption as if fully implemented.
Because the rules differ in individual countries, limitations on the encryption
included in the particular software being delivered, are covered in the Release
Notes that accompany the individual software release.
Cross references
Throughout this manual, cross references are made to the chapter numbers and
section names. The section name cross references are printed bold in text.
This manual is divided into uniquely identified and numbered chapters that, in
turn, are divided into sections. Sections are not numbered, but are individually
named at the top of each page, and are listed in the table of contents.
Text conventions
The following conventions are used in the Motorola cellular infrastructure
manuals to represent keyboard input text, screen output text and special key
sequences.
Input
Characters typed in at the keyboard are shown like
this.
Output
Messages, prompts, file listings, directories, utilities, and
environmental variables that appear on the screen are shown like
this.
CTRLc
ALTf
CR or RETURN
GMR-01
26 Sep 2003
GSM
Procedure
Whenever a safety issue arises:
1.
2.
3.
4.
Collect evidence from the equipment under the guidance of the Customer
Network Resolution Centre.
68P02902W97-A
GMR-01
GSM
Warnings
Definition of Warning
A warning is used to alert the reader to possible hazards that could cause loss
of life, physical injury, or ill health. This includes hazards introduced during
maintenance, for example, the use of adhesives and solvents, as well as those
inherent in the equipment.
Cautions
Definition of Caution
A caution means that there is a possibility of damage to systems, software or
individual items of equipment within a system. However, this presents no danger
to personnel.
GMR-01
26 Sep 2003
General warnings
GSM
General warnings
Introduction
Observe the following specific warnings during all phases of operation,
installation and maintenance of the equipment described in the Motorola
manuals:
S
Electric shock
RF radiation
Laser radiation
Heavy equipment
Parts substitution
Battery supplies
Lithium batteries
Failure to comply with these warnings, or with specific warnings elsewhere in the
Motorola manuals, violates safety standards of design, manufacture and
intended use of the equipment. Motorola assumes no liability for the customers
failure to comply with these requirements.
Warning labels
Warnings particularly applicable to the equipment are positioned on the
equipment. Personnel working with or operating Motorola equipment must
comply with any warning labels fitted to the equipment. Warning labels must not
be removed, painted over or obscured in any way.
68P02902W97-A
GMR-01
General warnings
GSM
Specific warnings
Specific warnings used throughout the GSM manual set are shown below.
These will be incorporated into procedures as applicable.
These must be observed by all personnel at all times when working with the
equipment, as must any other warnings given in text, in the illustrations and on
the equipment.
Electric shock
WARNING
Do not touch the victim with your bare hands until the
electric circuit is broken.
Switch off. If this is not possible, protect yourself with dry
insulating material and pull or push the victim clear of the
conductor.
ALWAYS send for trained first aid or medical assistance
IMMEDIATELY.
In cases of low voltage electric shock (including public supply voltages), serious
injuries and even death, may result. Direct electrical contact can stun a casualty
causing breathing, and even the heart, to stop. It can also cause skin burns at
the points of entry and exit of the current.
In the event of an electric shock it may be necessary to carry out artificial
respiration. ALWAYS send for trained first aid or medical assistance
IMMEDIATELY.
If the casualty is also suffering from burns, flood the affected area with cold
water to cool, until trained first aid or medical assistance arrives.
GMR-01
26 Sep 2003
General warnings
GSM
RF radiation
WARNING
Relevant standards (USA and EC), to which regard should be paid when
working with RF equipment are:
S
ANSI IEEE C95.1-1991, IEEE Standard for Safety Levels with Respect to
Human Exposure to Radio Frequency Electromagnetic Fields, 3 kHz to
300 GHz.
Laser radiation
WARNING
Lifting equipment
WARNING
68P02902W97-A
GMR-01
General warnings
GSM
Parts substitution
WARNING
Battery supplies
WARNING
Lithium batteries
WARNING
Contact your local Motorola office for how to return defective lithium batteries.
10
GMR-01
26 Sep 2003
General cautions
GSM
General cautions
Introduction
Observe the following cautions during operation, installation and maintenance of
the equipment described in the Motorola manuals. Failure to comply with these
cautions or with specific cautions elsewhere in the Motorola manuals may result
in damage to the equipment. Motorola assumes no liability for the customers
failure to comply with these requirements.
Caution labels
Personnel working with or operating Motorola equipment must comply with any
caution labels fitted to the equipment. Caution labels must not be removed,
painted over or obscured in any way.
Specific cautions
Cautions particularly applicable to the equipment are positioned within the text
of this manual. These must be observed by all personnel at all times when
working with the equipment, as must any other cautions given in text, on the
illustrations and on the equipment.
Fibre optics
CAUTION
Static discharge
CAUTION
68P02902W97-A
GMR-01
11
GSM
Leave the short circuit on the leads until the last moment. It may be
necessary to replace the conductive foam by a piece of wire to enable the
device to be fitted.
Do not wear outer clothing made of nylon or similar man made material. A
cotton overall is preferable.
All metal tools should be used and when not in use they should be placed
on an earthed surface.
When mounted onto printed circuit boards (PCBs), MOS devices are normally
less susceptible to electrostatic damage. However PCBs should be handled with
care, preferably by their edges and not by their tracks and pins, they should be
transferred directly from their packing to the equipment (or the other way
around) and never left exposed on the workbench.
12
GMR-01
26 Sep 2003
GSM
Name
68P02901W01
68P02901W14*
68P02901W19
68P02901W34**
68P02901W36
68P02901W23
68P02901W17
68P02901W43
68P02901W47
68P02901W26
68P02901W58
68P02901W57
68P02901W51
68P02901W56
68P02901W72
68P02901W74
**
68P02902W97-A
GMR-01
13
GSM
Name
Name
68P02903W01
System Information: GPRS Overview
68P02903W03
Operating Information: OMC-G System Administration
68P02903W37
Operating Information: GSN System Administration
68P02903W46
Technical Description: OMC-G Database Schema
68P02903W18 * Technical Description: GSN Command Reference
68P02903W47
Installation & Configuration: GSN Clean Install
68P02903W04
Installation & Configuration: OMC-G Clean Install
68P02903W19 * Maintenance Information: Alarm Handling at the OMC-G
68P02903W20
Maintenance Information: GSN Statistics Application
68P02903W76
Software Release Notes: GSN System
68P02903W70
Software Release Notes: OMC-G System
*
14
Name
GMR-01
26 Sep 2003
GSM
Name
Name
Order number
The Motorola 68P order (catalogue) number is used to order manuals.
68P02902W97-A
GMR-01
15
GSM
Ordering manuals
All orders for Motorola manuals must be placed with your Motorola Local Office
or Representative. Manuals are ordered using the order (catalogue) number.
Manuals are available on the following media:
Printed hard copy
Electronic:
16
GMR-01
26 Sep 2003
GMR amendment
GSM
GMR amendment
Introduction to GMRs
Changes to a manual that occur after the printing date are incorporated into the
manual using General Manual Revisions (GMRs). GMRs are issued to correct
Motorola manuals as and when required. A GMR has the same identity as the
target manual. Each GMR is identified by a number in a sequence that starts at
01 for each manual at each issue.
GMR availability
GMRs are published as follows:
S
68P02902W97-A
GMR-01
17
GSM
Amendment record
Record the insertion of GMRs in this manual in the following table:
GMR number
01
Incorporated by (signature)
.Incorporated (this GMR)
Date
26 Sep 2003
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
18
GMR-01
26 Sep 2003
Chapter 1
68P02902W97-A
GMR-01
11
GSM
12
GMR-01
26 Sep 2003
Introduction to installation
GSM
Introduction to installation
Manual scope
This manual covers installation and commissioning for the Horizon II macro
cabinet, arranged in the following chapters:
Chapter 1
Chapter 2
All the procedures necessary to install the cabinet ready for operation and an
overview of the different configurations available.
Chapter 3
Chapter 4
Chapter 5
Safety instructions
WARNING
Installation and commissioning must comply with all relevant national and
regional regulations.
Cabinets must be bolted to the plinth base, which must be bolted to the
floor.
Installation & Configuration: Horizon II macro
26 Sep 2003
68P02902W97-A
GMR-01
13
GSM
Safety goggles
Hard hat
Dust mask
1 pair
Ear defenders
Antistatic mat
Marker pen
Torch
1 each
1 each
Torxdriver set (T10 to T30) and Security Torxdriver set (T10 to T30)
Claw hammer
Pipe cutter
Junior hacksaw
300 mm hacksaw
1 pair
1 pair
1 pair
1 pair
1 pair
Cable shears
1
1 pair
14
Description
GMR-01
26 Sep 2003
GSM
Quantity
Description
1 pair
1 pair
Industrial scissors
1 pair
50 mm crimp tool
Table vice
Spirit level (1 m)
Centre punch
Pocket scriber
1 pair
Null modem
M to M gender changer
68P02902W97-A
GMR-01
15
Preparation overview
GSM
Preparation overview
Overview of site preparation
This section contains:
S
Pre-installation procedures
Pre-installation for the cabinet comprises the sections listed in Table 1-2.
Table 1-2 Pre-installation sections in this chapter
Section
Description
16
GMR-01
26 Sep 2003
GSM
Software requirements
All Horizon II macro BTSs require software release GSR6 (Horizon II) or later in
the network.
EMC
EN301 489-8
Safety
Environmental limits
Table 1-4 lists the environmental limits for Horizon II macro operation and
storage.
Table 1-4 Environmental limits
Environment
Temperature
Relative Humidity
Operating
5 _C to + 45 _C.
Storage
45 _C to +70 _C.
NOTE
68P02902W97-A
GMR-01
17
GSM
Power requirements
Cabinet power supply requirements
Table 1-5 lists the power supply requirements for the different power supply
options.
Table 1-5 Horizon II macro cabinet power supply requirements
Nominal Voltage
Voltage supply
range
+19.5 to +30 V dc
48 V dc (positive earth)
39 to 72 V dc
88 to 270 V
NOTE
Power consumption
Table 1-6 lists typical and worst case power consumption values for example
Horizon II macro configurations.
Table 1-6 Horizon II macro power consumption details
Example
configuration
co
fig ratio
Typical
Worst case
Typical
Worst case
1107
1664
957
1331
2152
3155
1862
2524
1365
1835
1180
1468
2668
3498
2308
2798
NOTE
Battery backup
The Horizon II macro cabinet has no internal battery backup as standard.
Additional battery backup capacity can be provided by installation of an optional
external battery back up system (BBS). Contact the Motorola local office for
further details.
18
GMR-01
26 Sep 2003
GSM
RF power output
Table 1-7 and Table 1-8 list the RF power output of the CTU2 for the 900 MHz
and 1800 MHz frequency bands in the various configuration options available.
Table 1-7 CTU2 RF power output (installed in Horizon II macro cabinet)
CTU2 configuration
co fig ratio
Co bi i g
Combining
Single density
DCS1800
No external combining
63 W
50 W
Double density
No external combining
20 W
16 W
2 x double density
1 internal + 1 external
stage hybrid combining
9W
7W
Co bi i g
Combining
Single density
DCS1800
No external combining
40 W
32 W
Single density
20 W
16 W
Double density
No external combining
10 W
10 W
2 x double density
1 internal + 1 external
stage hybrid combining
5W
5W
NOTE
68P02902W97-A
GMR-01
19
GSM
Sensitivity
The receiver sensitivity performance of the equipment is shown in Table 1-9.
Table 1-9 Rx sensitivity performance
Co ditio s
Conditions
EGSM900
DCS1800
Typical
Guaranteed
Typical
Guaranteed
Static channel
111.5 dBm
110.5 dBm
112.5 dBm
111.5 dBm
Faded channel
108.5 dBm
107.5 dBm
109.5 dBm
108.5 dBm
Up to
113.5 dBm
Up to
112.5 dBm
Up to
114.5 dBm
Up to
113.5 dBm
Typical values are the average expected performance over the frequency
band when measured at the main branch BTS antenna port, i.e. the
duplexer antenna port.
110
GMR-01
26 Sep 2003
GSM
Cabinet dimensions
The dimensions of cabinets are shown in Table 1-10.
Table 1-10 Cabinet dimensions
Cabinet type
Height
Width
Depth
750 mm
700 mm
430 mm
870 mm
700 mm
430 mm
1025 mm
700 mm
430 mm
1900 mm
700 mm
430 mm
The optional hood allows cables to enter the cabinet from the back and above.
The stacking bracket allows a second cabinet to be stacked on top of the first
cabinet.
Weights
The maximum weight of the cabinet is shown in Table 1-11.
Consider future expansion. Another cabinet may be added
by stacking on top of the existing cabinet. This could result
in a total weight of up to 290 kg. Ensure the floor is
capable of supporting this weight.
CAUTION
Weight
Cabinet, empty
52.7 kg
135 kg
Plinth
7.8 kg
Hood
2.03 kg
9.3 kg
Torque values
Table 1-12 details torque values used during installation, maintenance and
repair procedures.
Table 1-12 Torque values for all cabinet screws/bolts and RF connectors
Screw/bolt size
Torque value
NOTE
M4
M6
M8
M10
2.2 Nm 3.4 Nm 5 Nm 10 Nm
SMA
N-type
7/16
1 Nm
3.4 Nm 25 Nm
68P02902W97-A
GMR-01
111
GSM
Frequency capability
Frequency hopping
The Horizon II macro supports baseband frequency hopping (BBH) and
synthesizer frequency hopping (SFH).
NOTE
112
GSM900
EGSM
DCS1800
935 to 960
925 to 960
1805 to 1880
890 to 915
880 to 915
1710 to 1785
Transmit/receive duplex
separation (MHz)
45
45
95
200
200
200
Number of channels
124
174
374
935.0 to
935.1
959.9 to
960.0
925.0 to
925.1
959.9 to
960.0
1805.0 to
1805.1
1879.9 to
1880.0
890.0 to
890.1
914.9 to
915.0
880.0 to
880.1
914.9 to
915.0
1710.0 to
1710.1
1784.9 to
1785.0
Even 10ths
of a MHz
from 935.2
to 959.8
Even 10ths
of a MHz
from 925.2
to 959.8
Even 10ths of
a MHz from
1805.2 to
1879.8
Even 10ths
of a MHz
from 890.2
to 914.8
Even 10ths
of a MHz
from 880.2
to 914.8
Even 10ths of
a MHz from
1710.2 to
1784.8
GMR-01
26 Sep 2003
GSM
Structural considerations
Adequate clearance must be provided at the front of the cabinet for operation
and maintenance purposes. There must be adequate side clearance (50 mm) to
enable the door to open beyond 90 (see Figure 1-1). The door can also stop at
95 and 150 , but this is only to protect the door, or give optional additional
operator space.
The cabinet ventilation entry can be solely from the bottom front of the cabinet.
This allows a cabinet to be placed against a wall. However, if the unit is placed
50 mm from back or side obstructions, such as wall or other cabinets, the
ventilation will be improved, and fan noise reduced.
Up to 100 mm rear space may be required for cables if using a stacking bracket.
The foundation or structure on which the BTS cabinet is mounted must be of
sufficient strength to support the maximum gross weight of the equipment, as
defined in Table 1-11.
NOTE
Layout plan
Figure 1-1 shows the cabinet installation layout plan.
Figure 1-1 Horizon II macro cabinet site layout plan
100 mm clearance if using stacking
bracket to allow cable space
700 mm
50 mm minimum side
clearance for door opening
Horizon II macro
CABINET
430 mm
70 mm width
when door at 95
610 mm width when
door at 150
700 mm door at
second position (150)
700 mm door at
first position (95)
68P02902W97-A
GMR-01
113
GSM
Check that team members have adequate test equipment, tools, and
hardware to complete the tasks. Check for any special requirements.
2.
3.
Ensure that the team read the site access details on each visit to a site as
local regulations may change.
Arrival at site
When entering any site:
1.
Contact the communications site manager before entering the site. Obtain
the following information from the on-site contact:
Local regulations.
Parking instructions.
2.
3.
Check for building alarms, for example, intruder alarms, that may have
been activated by entry. If fitted, disable the CO2 gas systems, and any
other alarms activated by entry.
4.
114
1.
Enable the CO2 gas system, if fitted, and any alarms that were disabled.
2.
3.
GMR-01
26 Sep 2003
GSM
Rural sites
It is the responsibility of the senior member of the team to ensure that all
personnel on site are aware of all applicable national and regional
environmental regulations or codes of practice and, especially with respect to
water authority sites, any relevant health regulations.
Adhere to these points:
S
Fasten all gates (remember site visits can be traced back if a complaint is
made).
On site safety
All personnel must:
S
Wear supplied safety goggles and dust masks when drilling. This is
particularly important when drilling overhead ironwork.
Stop any work that is being supervised if any person in the team is not properly
protected, or is unaware of safety requirements.
When installing cable ties, even temporarily, cut the excess or tail properly. This
is to prevent sharp edges inflicting injury when not cut flush with the locking
edge.
68P02902W97-A
GMR-01
115
GSM
Site requirements
The customer should provide secure access free from unauthorized personnel,
ample protection from fire, and adequate lighting and clearance at the front and
rear of the equipment for operation and maintenance. Additionally, four cable
ducts with sufficient space for communications cables, mains cables, earth
cables, and antenna RF cables should be provided.
Site access
The site access road and equipment receiving area must be constructed of
asphalt, concrete, or other suitable load bearing aggregate capable of
supporting the transportation vehicle and the cabinet.
NOTE
116
GMR-01
26 Sep 2003
Chapter 2
68P02902W97-A
GMR-01
21
GSM
22
GMR-01
26 Sep 2003
Installation overview
GSM
Installation overview
Introduction to installation
This chapter provides the information required to install Horizon II macro
cabinets and the internal and external interfaces.
CAUTION
NOTE
Before starting an installation, ensure the site has been prepared according to
the description summarized in Preparation overview in Chapter 1, and the
site-specific documentation.
WARNING
68P02902W97-A
GMR-01
23
Installation overview
GSM
Installation sections
Cabinet Installation comprises the sections shown in Table 2-1.
Table 2-1 Installation sections in this chapter
Section
Description
Equipment delivery
and unpacking
Installing cabinet
plinth
Hood or stacking
bracket fit
Earthing and transient Details site earthing procedures and cabinet internal
protection
earths.
24
Connecting antennas
and cabinet
configurations
Interface cabling
Connecting input
power
GMR-01
26 Sep 2003
Installation overview
GSM
TWO
SURF2s
TWO SITE
EXPANSION
BOARDS
(OPTIONAL)
UP TO FOUR
PSUs
3 x HEAT
SENSORS
LOCATED ON
BACKPLANE
SIX CTU2s
THREE
2-FAN UNITS
PLINTH
ALARM
MODULE
TWO HIISCs
(REPLACED BY XMUXs IN
EXPANSION CABINET)
68P02902W97-A
GMR-01
25
GSM
The equipment should be carefully delivered to the site by the freight company,
along with the necessary moving dollies and padding. Use the dollies and
padding to move the equipment from the unloading area to the installation point.
NOTE
Packaging crate
The cabinet equipment is shipped in a crate of a similar construction to that
shown in Figure 2-2.
Figure 2-2 Typical shipping crate detail
26
GMR-01
26 Sep 2003
GSM
Tools
Use the following tools to dismantle the crate and unpack the cabinet.
S
Knife.
2.
Remove the crate lid and deliver the plinth to site for site preparation, if
required separately.
3.
If the cabinet is not to be installed at the same time as the plinth, refit the
lid and secure the crate.
2.
3.
4.
68P02902W97-A
GMR-01
27
GSM
1.
Carefully cut open the sealed barrier bag containing the cabinet.
2.
Use straps attached to the plywood base holding the cabinet, to lift cabinet
over the delivery pallet and foam packing pieces.
3.
4.
Inspect the equipment immediately for damage. Report the extent of any
damage to the transport company.
28
GMR-01
26 Sep 2003
GSM
The plinth is first fitted to the floor, then the cabinet is slid into the plinth and
bolted to it. Figure 2-3 shows the plinth with locations for both floor and cabinet
attachment.
Figure 2-3 Plinth, showing mounting points
99 mm
99 mm
503 mm
202 mm
80 mm
LOCATIONS FOR
CABINET ATTACHMENT
ig.332.rh
68P02902W97-A
GMR-01
29
GSM
If the installation is new, the concrete floor must be drilled to accept M12 anchor
bolts. Washers and bushes are supplied, but the M12 steel bolts must be
supplied by the customer.
1.
Move the cabinet plinth to the selected mounting position. Consider future
as well as present space requirements (see Site requirements and BTS
specifications in Chapter 1).
2.
Mark the positions of the four square mounting holes in the base of the
plinth (see Figure 2-3).
3.
CAUTION
4.
Drill out the four holes to a depth and clearance for an M12 anchor bolt,
using the plinth as a template.
5.
6.
7.
Fit the anchor bolts with the supplied bushes and washers, through the
plinth floor, to each anchor.
8.
Tension up the anchor bolts and then check for alignment and level using
a spirit level.
9.
When satisfied that the plinth is correctly aligned, torque the bolts to the
correct value.
NOTE
210
GMR-01
26 Sep 2003
GSM
For floor mounting, with the plinth previously secured firmly to the floor.
Mounting instructions
To mount the cabinet onto the plinth:
1.
Remove the two M10 bolts attached to the front of the plinth.
WARNING
2.
Tilt and slide the cabinet off the plywood base and move to the plinth,
using the straps provided.
3.
4.
Fit the two M10 bolts and tighten to correct torque (see Site requirements
and BTS specifications in Chapter 1).
M10 BOLT
LOCATION
M10 BOLT
POSITIONS FOR
INSERTION
68P02902W97-A
GMR-01
211
GSM
A = Remove for hood and stacking bracket. For hood only, replace with hood pin.
B = Additional screws to be removed for stacking bracket only.
212
GMR-01
26 Sep 2003
GSM
2.
Screw the four pins into the cabinet top panel. Tighten to the correct
torque (see Site requirements and BTS specifications in Chapter 1).
3.
Align the hood with the back pins, then lower the hood onto the pins, and
press firmly into place.
Figure 2-6 shows a top view of the hood as seen when fitted to the cabinet.
HOOD
TOP SECTION OF
CABINET DOOR
68P02902W97-A
GMR-01
213
GSM
2.
Lift the hood by the rear lifting edge, until it disengages from the
pins.
b.
Unscrew and remove the four pins from the cabinet. Store the
pins with the hood.
Remove the eight (or four remaining) M8 screws form the cabinet top
panel as shown in Figure 2-7 and retain.
WARNING
3.
Align the stacking bracket onto the cabinet, and fit the eight M8 screws.
Tighten to the correct torque (see Site requirements and BTS
specifications in Chapter 1).
4.
Fit the front cover following the procedure described in Fitting the
stacking bracket front cover.
214
GMR-01
26 Sep 2003
GSM
Align the four locating clips on the front cover with the four square holes in
the front of the stacking bracket. Ensure that the cut out slot on each clip
is facing downwards.
2.
Press the cover against the stacking bracket, so that the cut out slot on
each locating clip engages with the bottom edge of each square hole. It
may be necessary to gently push in and down to ensure the cut out slots
are fully engaged and the cover securely in place.
Figure 2-8 shows the locating points for the stacking bracket front cover.
FRONT
COVER
68P02902W97-A
GMR-01
215
GSM
Eyebolt locations
Figure 2-9 shows the locations where eyebolts are fitted so that the cabinet can
be lifted.
EYEBOLT
POSITIONS
216
GMR-01
26 Sep 2003
GSM
For the subsequent use of eyebolts, there may be local regulations that govern
the use of lifting equipment and stipulate a test and/or examination regime. If
the eyebolts are to be used, ensure that all such regulations are met.
Eyebolts can be fitted into the four designated cabinet top panel locations
shown in Figure 2-9 after removal of the screws. These locations are identified
with an eyebolt symbol and the word LIFT. The eyebolt locations are also used
for stacking bracket attachment.
68P02902W97-A
GMR-01
217
GSM
Ensure the stacking bracket is fitted correctly onto the lower cabinet. If not,
refer to Fitting a stacking bracket.
2.
3.
4.
Fit the eyebolts to the locations identified with an eyebolt symbol and the
word LIFT. hand tighten the eyebolts and, using suitable lifting equipment,
lift the cabinet onto the stacking bracket and slide to position.
5.
Attach four M10 bolts to the cabinet plinth from underneath the top of the
stacking bracket. Tighten to the correct torque (see Site requirements
and BTS specifications in Chapter 1).
6.
If required, fit an optional hood on the top panel of the upper cabinet (see
Fitting an optional hood).
CAUTION
7.
Fit the stacking bracket front cover onto the stacking bracket, using the
procedure described in Fitting the stacking bracket front cover.
218
GMR-01
26 Sep 2003
GSM
Horizon II macro
CABINETS
FRONT COVER ON
STACKING BRACKET
68P02902W97-A
GMR-01
219
GSM
The cell site equipment must be earthed (in the same common earth point
as its power source).
Provision should be made for routeing earthing lines into the site and to
the cabinet before beginning the installation of the system cabinets.
Earthing posts are located on the interface panel on top of each cabinet.
220
GMR-01
26 Sep 2003
Connections to RF modules
GSM
Connections to RF modules
Overview of RF connections
The components shown in Figure 2-11 provide all the RF connections to the
cabinet, and internally within the cabinet. A maximum of four cabinets can be
interconnected to form a single BTS site.
UP TO 6
CTU2s
68P02902W97-A
GMR-01
221
Connections to RF modules
GSM
Types of RF connector
Table 2-2 lists the RF module connectors with their destinations.
Table 2-2 RF module connectors and destinations
RF module
Type of connector
Destination
CTU2
SMA
DUP (underneath)
HCU (underneath)
DHU (underneath)
Feedthrough plate
(underneath)
DUP
SMA (underneath)
N-type
SURF2
7/16
antenna
HCU or DHU
QMA (underneath)
DUP
Feedthrough plate
SMA (underneath)
CTU2 or another Tx
block
Feedthrough plate in
expansion cabinet
N-type
Rx N-type of DUP
SURF2
Description
Use
3086225N01
DUP to SURF2
3086225N03
SURF2 to SURF2
3086898W01
DUP to HCU/DHU
222
GMR-01
26 Sep 2003
Connections to RF modules
GSM
RF connection principles
The primary receive path is connected to the A branch of the SURF2 module,
either directly or from the Rx connector on the Tx block in non-diversity
configurations. The diversity receive path is connected to the B path on the
SURF2. This is normally duplexed with the transmit signal on a single antenna,
and fed to the SURF2 from the Rx connector on the Tx block. Within any single
cabinet the lowest numbered sector is normally connected to amplifier 0
connections, and higher numbered sectors to amplifiers 1 and 2 as appropriate.
For example, sector one is connected to SURF2 connectors 0A and 0B, sector
two to 1A and 1B, and sector three to 2A and 2B. However, if a sector is split
between two cabinets, the split sector antennas must be connected to amplifier
0, (this is the only path with connection to the expansion ports). Expansion ports
must be connected to the correct branch at the destination cabinet.
The transmit path feeds from the CTU2 to the Tx block or feedthrough plate
mounted above. The output of one, two, three or four CTU2s can be fed into the
DUP, depending on whether the connection is direct or indirect (via a HCU or
DHU). The DUP then duplexes the Tx signal with the diversity Rx signal, before
feeding to the antenna.
Figure 2-12 shows the RF signal path options between the CTU2 and DUP.
Figure 2-12 CTU2 to DUP RF path options
ANTENNA
DUP
ANTENNA
OR
CTU2
HCU
CTU2
DUP
ANTENNA
OR
CTU2
DCU
CTU2
CTU2
DUP
CTU2
ANTENNA
OR
HCU
CTU2
CTU2
DCU
CTU2
DUP
CTU2
68P02902W97-A
GMR-01
223
Connections to RF modules
GSM
224
GMR-01
26 Sep 2003
Suggested RF configurations
GSM
Suggested RF configurations
Overview of configuration diagrams
The following series of RF configuration diagrams show suggested ways of
connecting together Horizon II macro SURF2 and Tx blocks to meet different
operational requirements. The series of diagrams is by no means exhaustive,
and numerous alternative configurations may be adopted to achieve the same
aim.
Each Horizon II macro cabinet is represented by six CTU2 slots (populated as
appropriate), a SURF2 module (or two SURF2 modules, in the case of
Figure 2-40), six Tx block slots (populated as appropriate) and interconnecting
cables. Antenna connecting cables, not supplied as part of the Horizon II macro
equipment, are shown as dashed lines.
The diagrams are applicable to EGSM900 or DCS1800 single band operation.
GSM single carrier, dual carrier and EDGE single carrier power output figures
are given for each configuration.
Diversity is assumed in all RF configuration diagrams shown here. For non
diversity, the single receive path is always connected to branch A at the SURF2
module.
The RF configuration diagrams in this section are
purely diagrammatic representations and are not
intended to reflect the actual physical layout of
equipment.
NOTE
Digital connections
Digital connections between cabinets are not shown in detail in the following
diagrams. Fibre optic cables used to provide digital connections between
cabinets are described in Connecting fibre optic cables.
Assumptions
These assumptions apply to all the following RF configuration diagrams:
S
All unused Tx block SMA connectors are fitted with 50 ohm terminating
loads.
All unused slots in the Tx basket are fitted with blanking plates
Installation & Configuration: Horizon II macro
26 Sep 2003
68P02902W97-A
GMR-01
225
Suggested RF configurations
GSM
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
0
RX
ANT
BLANK
BLANK
BLANK
BLANK
BLANK
DUP
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
CTU2
Output Power
Configuration
Co fig ratio
226
900 MHz
1800 MHz
63 W (48.0 dBm)
50 W (47.0 dBm)
20 W (43.0 dBm)
16 W (42.0 dBm)
20 W (43.0 dBm)
16 W (42.0 dBm)
GMR-01
26 Sep 2003
Suggested RF configurations
GSM
Figure 2-14 Single cabinet, omni 2 or 4 with DUP and air combining
SECTOR 1
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
RX
RX
ANT
ANT
BLANK
BLANK
BLANK
BLANK
DUP
DUP
EMPTY
EMPTY
EMPTY
EMPTY
CTU2
CTU2
Output Power
Configuration
Co fig ratio
900 MHz
1800 MHz
63 W (48.0 dBm)
50 W (47.0 dBm)
20 W (43.0 dBm)
16 W (42.0 dBm)
20 W (43.0 dBm)
16 W (42.0 dBm)
68P02902W97-A
GMR-01
227
Suggested RF configurations
GSM
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
0
RX
HCU
ANT
BLANK
BLANK
BLANK
BLANK
EMPTY
EMPTY
EMPTY
EMPTY
CTU2
CTU2
Output Power
Configuration
Co fig ratio
228
DUP
900 MHz
1800 MHz
28 W (44.5 dBm)
22 W (43.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
GMR-01
26 Sep 2003
Suggested RF configurations
GSM
Figure 2-16 Single cabinet, omni 3 or 6 with DUP, HCU and air combining
SECTOR 1
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
RX
0
RX
HCU
ANT
ANT
BLANK
BLANK
BLANK
DUP
DUP
EMPTY
EMPTY
EMPTY
CTU2
CTU2
CTU2
Output Power
Configuration
Co fig ratio
900 MHz
1800 MHz
28 W (44.5 dBm)
22 W (43.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
68P02902W97-A
GMR-01
229
Suggested RF configurations
GSM
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
DHU
RX
ANT
BLANK
BLANK
BLANK
BLANK
EMPTY
EMPTY
EMPTY
CTU2
CTU2
CTU2
Output Power
Configuration
Co fig ratio
230
DUP
900 MHz
1800 MHz
11 W (40.5 dBm)
9 W (39.5 dBm)
GMR-01
26 Sep 2003
Suggested RF configurations
GSM
Figure 2-18 Single cabinet, omni 4 or 8 with DUP, HCU and air combining
SECTOR 1
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
4
HCU
BLANK
BLANK
EMPTY
EMPTY
RX
0A
CTU2
RX
1A
2
RX
RX
2A
0
RX
HCU
ANT
ANT
DUP
DUP
CTU2
CTU2
CTU2
Output Power
Configuration
Co fig ratio
900 MHz
1800 MHz
28 W (44.5 dBm)
22 W (43.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
68P02902W97-A
GMR-01
231
Suggested RF configurations
GSM
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
DHU
DHU
RX
RX
ANT
CTU2
CTU2
BLANK
CTU2
CTU2
DUP
CTU2
CTU2
Output Power
Configuration
Co fig ratio
232
ANT
DUP
BLANK
900 MHz
1800 MHz
11 W (40.5 dBm)
9 W (39.5 dBm)
GMR-01
26 Sep 2003
Suggested RF configurations
GSM
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
RX
2B
BLANK
BLANK
BLANK
EMPTY
EMPTY
CTU2
XMUX
CTU2
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
DHU
RX
CTU2
RX
0B
DHU
HCU
RX
1B
RX
HCU
ANT
ANT
DUP
DUP
BLANK
BLANK
BLANK
CTU2
CTU2
EMPTY
EMPTY
CTU2
CTU2
CTU2
SITE EXPANSION
BOARD
SLAVE CABINET
SITE EXPANSION
BOARD
HIISC
MASTER CABINET
Fibre Optic Link (x2)
Output Power
Configuration
Co fig ratio
900 MHz
1800 MHz
11 W (40.5 dBm)
9 W (39.5 dBm)
68P02902W97-A
GMR-01
233
Suggested RF configurations
GSM
RX
2B
RX
1B
SECTOR 1
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
RX
RX
ANT
BLANK
BLANK
DUP
BLANK
DUP
EMPTY
EMPTY
EMPTY
CTU2
EMPTY
CTU2
Output Power
Configuration
Co fig ratio
234
ANT
BLANK
900 MHz
1800 MHz
63 W (48.0 dBm)
50 W (47.0 dBm)
20 W (43.0 dBm)
16 W (42.0 dBm)
20 W (43.0 dBm)
16 W (42.0 dBm)
GMR-01
26 Sep 2003
Suggested RF configurations
GSM
Figure 2-22 Single cabinet, sector 2/2 or 4/4 with DUP and air combining
SECTOR 2
SECTOR 1
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
4
RX
RX
0A
RX
1A
RX
2A
RX
RX
RX
ANT
ANT
ANT
ANT
BLANK
BLANK
DUP
DUP
DUP
DUP
EMPTY
EMPTY
CTU2
CTU2
CTU2
CTU2
Output Power
Configuration
Co fig ratio
900 MHz
1800 MHz
63 W (48.0 dBm)
50 W (47.0 dBm)
20 W (43.0 dBm)
16 W (42.0 dBm)
20 W (43.0 dBm)
16 W (42.0 dBm)
68P02902W97-A
GMR-01
235
Suggested RF configurations
GSM
Figure 2-23 Single cabinet, sector 2/2 or 4/4 with DUP and HCU
SECTOR 2
RX
2B
RX
1B
SECTOR 1
RX
0B
EXP EXP
B
A
4
HCU
BLANK
BLANK
EMPTY
EMPTY
CTU2
RX
1A
2
RX
RX
2A
0
RX
HCU
ANT
ANT
DUP
DUP
CTU2
CTU2
CTU2
Output Power
Configuration
Co fig ratio
236
RX
0A
900 MHz
1800 MHz
28 W (44.5 dBm)
22 W (43.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
GMR-01
26 Sep 2003
Suggested RF configurations
GSM
Figure 2-24 Single cabinet, sector 3/3 or 6/6 with DUP, HCU and
air combining
SECTOR 2
SECTOR 1
RX
2B
RX
1B
5
RX
RX
0B
EXP EXP
B
A
4
HCU
RX
0A
3
RX
RX
1A
2
RX
RX
2A
0
RX
HCU
ANT
ANT
ANT
ANT
DUP
DUP
DUP
DUP
CTU2
CTU2
CTU2
CTU2
CTU2
CTU2
Output Power
Configuration
Co fig ratio
900 MHz
1800 MHz
28 W (44.5 dBm)
22 W (43.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
68P02902W97-A
GMR-01
237
Suggested RF configurations
GSM
Figure 2-25 Single cabinet, sector 3/3 or 6/6 with DUP and DHU
SECTOR 2
RX
2B
RX
1B
SECTOR 1
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
DHU
RX
2A
DHU
RX
RX
ANT
CTU2
CTU2
BLANK
CTU2
CTU2
DUP
CTU2
CTU2
Output Power
Configuration
Co fig ratio
238
ANT
DUP
BLANK
900 MHz
1800 MHz
11 W (40.5 dBm)
9 W (39.5 dBm)
GMR-01
26 Sep 2003
Suggested RF configurations
GSM
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
SECTOR 1
RX
0A
RX
2A
RX
2B
RX
HCU
RX
1A
ANT
BLANK
EMPTY
CTU2
CTU2
EMPTY
XMUX
CTU2
RX
1A
RX
2A
2
HCU
ANT
BLANK
CTU2
EMPTY
CTU2
BLANK
CTU2
EMPTY
0
RX
ANT
DUP
SITE EXPANSION
BOARD
SLAVE CABINET
RX
0A
RX
HCU
DUP
EXP EXP
B
A
ANT
DUP
BLANK
RX
0B
RX
HCU
RX
1B
DUP
CTU2
SITE EXPANSION
BOARD
CTU2
HIISC
MASTER CABINET
Fibre Optic Link (x2)
Output Power
Configuration
Co fig ratio
900 MHz
1800 MHz
28 W (44.5 dBm)
22 W (43.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
68P02902W97-A
GMR-01
239
Suggested RF configurations
GSM
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
SECTOR 1
RX
0A
RX
1A
ANT
RX
0B
CTU2
CTU2
XMUX
CTU2
EXP EXP
B
A
RX
0A
RX
2A
1
RX
ANT
BLANK
CTU2
CTU2
DHU
RX
DUP
CTU2
ANT
DUP
BLANK
CTU2
CTU2
SITE EXPANSION
BOARD
SLAVE CABINET
RX
1A
DHU
ANT
BLANK
RX
1B
RX
DUP
BLANK
CTU2
DHU
RX
CTU2
RX
2B
DHU
RX
2A
DUP
CTU2
SITE EXPANSION
BOARD
CTU2
HIISC
MASTER CABINET
Fibre Optic Link (x2)
Output Power
Configuration
Co fig ratio
240
900 MHz
1800 MHz
11 W (40.5 dBm)
9 W (39.5 dBm)
GMR-01
26 Sep 2003
Suggested RF configurations
GSM
Figure 2-28 Four cabinets, sector 8/8 with DUP, HCU, DHU and air combining
(Part A)
SECTOR 2
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
2A
DHU
RX
HCU
ANT
BLANK
BLANK
BLANK
EMPTY
EMPTY
CTU2
XMUX
SLAVE CABINET #3
CTU2
CTU2
DHU
RX
HCU
RX
1A
ANT
DUP
BLANK
BLANK
BLANK
CTU2
EMPTY
EMPTY
CTU2
SITE EXPANSION
BOARD
XMUX
DUP
CTU2
CTU2
CTU2
SITE EXPANSION
BOARD
SLAVE CABINET #2
TO SITE EXPANSION
BOARD IN MASTER
CABINET
68P02902W97-A
GMR-01
241
Suggested RF configurations
GSM
Figure 2-29 Four cabinets, sector 8/8 with DUP, HCU, DHU and air combining
(Part B)
SECTOR 1
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
2A
DHU
RX
HCU
ANT
BLANK
BLANK
BLANK
EMPTY
EMPTY
CTU2
CTU2
CTU2
XMUX
DHU
RX
HCU
RX
1A
ANT
DUP
BLANK
BLANK
BLANK
CTU2
EMPTY
EMPTY
CTU2
CTU2
SITE EXPANSION
BOARD
SLAVE CABINET #1
DUP
CTU2
SITE EXPANSION
BOARD
CTU2
HIISC
MASTER CABINET
Fibre Optic Link (x2)
Fibre Optic Link (x2)
TO SLAVE CABINET #2
TO SLAVE CABINET #3
Output Power
Configuration
Co fig ratio
900 MHz
1800 MHz
11 W (40.5 dBm)
9 W (39.5 dBm)
NOTE
242
GMR-01
26 Sep 2003
Suggested RF configurations
GSM
SECTOR 2
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
SECTOR 1
RX
RX
0A
RX
1A
RX
2A
RX
ANT
RX
ANT
ANT
BLANK
DUP
BLANK
DUP
BLANK
DUP
EMPTY
CTU2
EMPTY
CTU2
EMPTY
CTU2
Output Power
Configuration
Co fig ratio
900 MHz
1800 MHz
63 W (48.0 dBm)
50 W (47.0 dBm)
20 W (43.0 dBm)
16 W (42.0 dBm)
20 W (43.0 dBm)
16 W (42.0 dBm)
68P02902W97-A
GMR-01
243
Suggested RF configurations
GSM
Figure 2-31 Single cabinet, sector 2/2/2 or 4/4/4 with DUP and air combining
SECTOR 3
SECTOR 2
RX
2B
RX
1B
RX
0B
EXP EXP RX
0A
B
A
5
RX
RX
RX
RX
1A
RX
2A
2
RX
RX
0
RX
ANT
ANT
ANT
ANT
ANT
ANT
DUP
DUP
DUP
DUP
DUP
DUP
CTU2
CTU2
CTU2
CTU2
CTU2
CTU2
Output Power
Configuration
Co fig ratio
244
SECTOR 1
900 MHz
1800 MHz
63 W (48.0 dBm)
50 W (47.0 dBm)
20 W (43.0 dBm)
16 W (42.0 dBm)
20 W (43.0 dBm)
16 W (42.0 dBm)
GMR-01
26 Sep 2003
Suggested RF configurations
GSM
Figure 2-32 Single cabinet, sector 2/2/2 or 4/4/4 with DUP and HCU
SECTOR 3
SECTOR 2
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
HCU
CTU2
HCU
SECTOR 1
RX
0A
RX
1A
RX
2A
2
RX
0
RX
HCU
ANT
ANT
ANT
DUP
DUP
DUP
CTU2
CTU2
CTU2
CTU2
CTU2
Output Power
Configuration
Co fig ratio
900 MHz
1800 MHz
28 W (44.5 dBm)
22 W (43.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
68P02902W97-A
GMR-01
245
Suggested RF configurations
GSM
RX
2B
RX
1B
RX
0B
SECTOR 2
EXP EXP
B
A
RX
0A
RX
1A
2
RX
RX
2A
RX
2B
1
HCU
SECTOR 1
RX
1B
RX
RX
RX
0B
EXP EXP
B
A
4
RX
HCU
RX
0A
RX
1A
RX
2A
RX
HCU
0
RX
ANT
ANT
ANT
ANT
ANT
ANT
BLANK
BLANK
BLANK
DUP
DUP
DUP
DUP
DUP
DUP
EMPTY
EMPTY
EMPTY
CTU2
CTU2
CTU2
CTU2
CTU2
XMUX
CTU2
CTU2
SITE EXPANSION
BOARD
SLAVE CABINET
CTU2
SITE EXPANSION
BOARD
CTU2
HIISC
MASTER CABINET
Fibre Optic Link (x2)
Output Power
Configuration
Co fig ratio
246
900 MHz
1800 MHz
28 W (44.5 dBm)
22 W (43.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
GMR-01
26 Sep 2003
Suggested RF configurations
GSM
Figure 2-34 Two cabinets, sector 3/3/3 or 6/6/6 with DUP and DHU
SECTOR 3
RX
2B
RX
1B
RX
0B
SECTOR 2
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
RX
2B
SECTOR 1
RX
1B
RX
0B
BLANK
EMPTY
EMPTY
EMPTY
CTU2
XMUX
CTU2
RX
2A
RX
ANT
BLANK
RX
1A
RX
ANT
DUP
BLANK
CTU2
CTU2
CTU2
ANT
DUP
BLANK
CTU2
CTU2
SITE EXPANSION
BOARD
SLAVE CABINET
DHU
RX
BLANK
RX
0A
DHU
DHU
BLANK
EXP EXP
B
A
DUP
CTU2
SITE EXPANSION
BOARD
CTU2
HIISC
MASTER CABINET
Fibre Optic Link (x2)
Output Power
Configuration
Co fig ratio
900 MHz
1800 MHz
11 W (40.5 dBm)
9 W (39.5 dBm)
68P02902W97-A
GMR-01
247
Suggested RF configurations
GSM
RX
2B
RX
1B
5
HCU
CTU2
SECTOR 2
RX
0B
EXP EXP
B
A
RX
RX
0A
RX
2A
RX
2B
2
RX
HCU
RX
1A
SECTOR 1
HCU
0
RX
RX
1B
HCU
RX
0B
EXP EXP
B
A
RX
HCU
RX
0A
RX
1A
RX
2A
2
RX
HCU
0
RX
ANT
ANT
ANT
ANT
ANT
ANT
DUP
DUP
DUP
DUP
DUP
DUP
CTU2
CTU2
XMUX
CTU2
CTU2
CTU2
CTU2
CTU2
CTU2
SITE EXPANSION
BOARD
SLAVE CABINET
CTU2
CTU2
SITE EXPANSION
BOARD
CTU2
HIISC
MASTER CABINET
Fibre Optic Link (x2)
Output Power
Configuration
Co fig ratio
248
900 MHz
1800 MHz
28 W (44.5 dBm)
22 W (43.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
9 W (39.5 dBm)
7 W (38.5 dBm)
GMR-01
26 Sep 2003
Suggested RF configurations
GSM
Figure 2-36 Three cabinets, sector 6/6/6 with DUP, DHU and air combining
(Part A)
SECTOR 3
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
DHU
RX
2A
RX
RX
ANT
BLANK
CTU2
CTU2
DHU
ANT
DUP
BLANK
CTU2
CTU2
XMUX
DUP
CTU2
CTU2
SITE EXPANSION
BOARD
SLAVE CABINET #2
TO SITE EXPANSION
BOARD IN MASTER
CABINET
68P02902W97-A
GMR-01
249
Suggested RF configurations
GSM
Figure 2-37 Three cabinets, sector 6/6/6 with DUP, DHU and air combining
(Part B)
SECTOR 2
RX
2B
RX
1B
RX
0B
SECTOR 1
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
DHU
CTU2
RX
1B
RX
0B
BLANK
CTU2
CTU2
CTU2
XMUX
RX
0A
RX
1A
RX
2A
RX
ANT
DUP
BLANK
CTU2
CTU2
CTU2
ANT
DUP
BLANK
CTU2
CTU2
SITE EXPANSION
BOARD
DUP
CTU2
SITE EXPANSION
BOARD
SLAVE CABINET #1
DHU
RX
ANT
DUP
EXP EXP
B
A
DHU
RX
ANT
CTU2
DHU
RX
BLANK
RX
2B
CTU2
HIISC
MASTER CABINET
Fibre Optic Link (x2)
Fibre Optic Link (x2)
TO SLAVE CABINET #2
Output Power
Configuration
Co fig ratio
900 MHz
1800 MHz
11 W (40.5 dBm)
9 W (39.5 dBm)
NOTE
250
GMR-01
26 Sep 2003
Suggested RF configurations
GSM
SECTOR 3
TO 0B IN SLAVE CABINET #1
TO EXP A IN SLAVE CABINET #1
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
CTU2
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
DHU
RX
CTU2
RX
2A
DHU
HCU
RX
1A
RX
RX
0A
RX
1A
RX
2A
DHU
FTHRU
FTHRU
HCU
RX
HCU
ANT
ANT
ANT
DUP
DUP
DUP
BLANK
CTU2
CTU2
CTU2
CTU2
XMUX
SLAVE CABINET #3
CTU2
CTU2
CTU2
SITE EXPANSION
BOARD
CTU2
CTU2
XMUX
CTU2
SITE EXPANSION
BOARD
SLAVE CABINET #2
68P02902W97-A
GMR-01
251
Suggested RF configurations
GSM
Figure 2-39 Four cabinets, sector 8/8/8 with DUP, HCU, DHU and air combining
(Part B)
SECTOR
2
SECTOR 1
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
RX
2B
RX
BLANK
EXP EXP
B
A
RX
0A
CTU2
HCU
DHU
RX
FTHRU
RX
HCU
ANT
ANT
ANT
DUP
DUP
CTU2
XMUX
RX
2A
DUP
CTU2
FTHRU
RX
1A
DHU
HCU
CTU2
RX
0B
DHU
CTU2
RX
1B
CTU2
CTU2
CTU2
CTU2
SITE EXPANSION
BOARD
CTU2
CTU2
SITE EXPANSION
BOARD
SLAVE CABINET #1
CTU2
HIISC
MASTER CABINET
Fibre Optic Link (x2)
Fibre Optic Link (x2)
TO SLAVE CABINET #2
TO SLAVE CABINET #3
Output Power
Configuration
Co
fig ratio
8/8/8 GSM single carrier
8/8/8 EDGE single carrier
NOTE
252
900 MHz
1800 MHz
~9 W (~39.5 dBm)
~7 W (~38.5 dBm)
GMR-01
26 Sep 2003
Suggested RF configurations
GSM
Figure 2-40 Single cabinet, sector 2/2/2 or 4/4/4 with DUP and
air combining and 4 branch Rx diversity
SECTOR 3
SECTOR 2
SECTOR 1
RX
2C
RX
1C
RX
0C
EXP EXP
C
D
RX
0D
RX
1D
RX
2D
RX
2B
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
5
RX
RX
RX
2
RX
RX
RX
ANT
ANT
ANT
ANT
ANT
ANT
DUP
DUP
DUP
DUP
DUP
DUP
CTU2
CTU2
CTU2
CTU2
CTU2
CTU2
Output Power
Configuration
Co fig ratio
900 MHz
1800 MHz
63 W (48.0 dBm)
50 W (47.0 dBm)
20 W (43.0 dBm)
16 W (42.0 dBm)
68P02902W97-A
GMR-01
253
GSM
T43/CIM or
BIM/BIB
PIX1
EARTHING
POSTS
PIX0
EXTERNAL ALARMS
(SUPPLIED WITH
TERMINATION PLUG
FITTED)
NOTE
254
GMR-01
26 Sep 2003
GSM
Pin Nos
Pin Nos
Pin Nos
1+2
11
21+22
32
3 +4
12
23+24
33
5+6
13+14
25+26
34
7+8
15+16
27+28
35
17+18
29+30
36+37
10
19 +20
31
68P02902W97-A
GMR-01
255
GSM
BIM/BIB interconnection
To comply with North American safety regulations, BIM/
BIB twisted pair cables must be 26 AWG minimum.
CAUTION
The Balanced-line Interconnect Board (BIB), also known as BIM, provides the
line isolation between the E1/T1 circuit lines and the CBIA backplane. The
board provides an interface for up to six input and six output balanced 120 ohm
lines. 12 transformers are used to provide line isolation while maintaining
impedance matching between the E1/T1 circuit lines and the NIU part of the
HIISC. Each transformer has a 1:1 turn ratio to match the external and
backplane 120 ohm connections.
Connection is made using a 37-pin D-type connector to both the BIM/BIB and
the external PCM twisted pair circuit lines. Figure 2-42 shows a typical BIM/BIB
and Table 2-5 lists BIMBIB interconnections:
Figure 2-42 BIM/BIB
J0
J1
Equipment/Ext
Pin
no
Pin
no
Equipment/Ext
Pin
no
J0-1
Tx1+
J1-1
J0-20
Tx1
J1-20
J0-2
Rx1+
J1-2
J0-21
Rx1
J1-21
J0-4
Tx4+
J1-4
J0-23
Tx4
J1-23
J0-5
Rx4+
J1-5
J0-24
Rx4
J1-24
J0-7
Tx2+
J1-7
J0-26
Tx2
J1-26
J0-8
Rx2+
J1-8
J0-27
Rx2
J1-27
J0-10
Tx5+
J1-10 J0-29
Tx5
J1-29
J0-11
Rx5+
J1-11 J0-30
Rx5
J1-30
J0-13
Tx3+
J1-13 J0-32
Tx3
J1-32
J0-14
Rx3+
J1-14 J0-33
Rx3
J1-33
J0-16
Tx6+
J1-16 J0-35
Tx6
J1-35
J0-17
Rx6+
J1-17 J0-36
Rx6
J1-36
256
GMR-01
26 Sep 2003
GSM
T43/CIM interconnection
To comply with North American safety regulations, the
T43/CIM inner core must be 26 AWG minimum.
CAUTION
The Type 43 Interconnect Board (T43), also known as CIM, provides the
impedance matching and line isolation between the E1/T1 circuit lines and the
CBIA backplane. The board provides an interface for up to six input and six
output unbalanced coaxial 75 ohm lines. 12 transformers are used to provide
impedance matching and line isolation between the E1/T1 circuit lines and the
NIU part of the HIISC. Each transformer has a 1:1.25 turns ratio to match the
external 75 ohm and backplane 120 ohm connections.
Connection is made using a 37-pin D-type connector to the interconnect board
and 12 T43 coaxial connectors to the external E1/T1 circuit lines. Figure 2-43
shows a typical T43/CIM, and Table 2-6 lists the T43/CIM interconnections.
Figure 2-43 T43/CIM
J0
J8
J14
J4
J10
J16
J13
J2
J11
J7
J17
J1
J5
Equipment
/ Ext
Pin no
Pin
no
Equipment
/ Ext
Pin no
J0-1
Tx1+
J1 centre
J0-20
Tx1
J1 shield
J0-2
Rx1+
J2 centre
J0-21
Rx1
J2 shield
J0-4
Tx4+
J4 centre
J0-23
Tx4
J4 shield
j0-5
Rx4+
J5 centre
J0-24
Rx4
J5 shield
J0-7
Tx2+
J7 centre
J0-26
Tx2
J7 shield
J0-8
Rx2+
J8 centre
J0-27
Rx2
J8 shield
j0-10
Tx5+
J10 centre
J0-29
Tx5
J10 shield
j0-11
Rx5+
J11 centre
J0-30
Rx5
J11 shield
J0-13
Tx3+
J13 centre
J0-32
Tx3
J13 shield
J0-14
Rx3+
J14 centre
J0-33
Rx3
J14 shield
J0-16
Tx6+
J16 centre
J0-35
Tx6
J16 shield
J0-17
Rx6+
J17 centre
J0-36
Rx6
J17 shield
68P02902W97-A
GMR-01
257
GSM
PIX inputs/outputs
PIX outputs
PIX outputs comprise 4 relay contacts controlled by the alarm board and HIISC.
The relays have multiple contacts, some normally open and some normally
closed. The contacts are rated for 1 A at 30 V. The contacts may be used for
control of external equipment such as fans or audible alarms.
PIX inputs
PIX inputs comprise 16 connections to external sensors. These inputs report
alarms to the BSC, via the alarm board and HIISC, which forwards the alarms to
the OMC-R. The end-user supplies the external sensors. Each sensor connects
across an opto-coupled pair of PIX inputs (eight per PIX connector).
All sensors must be dry-contact type with the following specification:
S
5 kohm or greater across sense inputs for logic 1 (PIX opto-coupler off).
500 ohm or less across sense inputs for logic 0 (PIX opto-coupler on).
Table 2-7 shows PIX0 connections and Table 2-8 shows PIX1 connections.
Table 2-7 PIX0 pin connections (37-way D-type)
258
Pin
No
Signal/Description
Pin
No
Signal/Description
19
Not connected
20
21
22
23
24
25
26
Not connected
27
10
Not connected
28
spare
11
29
12
30
13
31
14
32
15
33
16
34
17
Not connected
35
Not connected
18
Not connected
36/37
Not connected
GMR-01
26 Sep 2003
GSM
Signal/Description
Pin
No
Signal/Description
19
Not connected
20
21
22
23
24
25
26
Not connected
27
68P02902W97-A
GMR-01
259
GSM
Length
Description
SVKN1244
5.6 m long
SVKN1245
7.6 m long
SVKN1246
7.6 m long
Care of fibres
Optical fibre cables contain an inner core, which is a strand of glass coated by a
cladding (sometimes in two layers), and an outer protective sheath which
provides mechanical protection.
The fibre acts as a light waveguide. In order for the link to work correctly light
must be propagated with minimal losses from end-to-end of the fibre. A number
of problems can prevent this from happening, resulting in a potentially faulty link.
Care must be taken to ensure that the conditions that follow are met.
260
GMR-01
26 Sep 2003
GSM
If fibres are bent tighter than the minimum bend radius then two possible effects
can happen:
S
Excessive light loss can occur from the outside of the bend, resulting in a
loss of performance.
For glass fibres (orange or green outer sheath) the long term minimum bend
radius is approximately 30 mm.
Figure 2-44 illustrates the minimum bend radius for fibre optic cables.
Figure 2-44 Fibre optic minimum bend radius
30 mm
If the fibre is under tension (being stretched), the bend radius should be much
larger, at least doubled. This is because the tension in the fibre can increase the
possibilities of damage.
If in doubt about the radius, the fibre should be allowed to form its natural bend
radius by allowing it to bend under gravity only. This natural bend radius is
normally greater than 30 mm.
Installation & Configuration: Horizon II macro
26 Sep 2003
68P02902W97-A
GMR-01
261
GSM
FIBRE OPTIC
CONNECTOR
262
OUT 2
(Tx)
IN 2
(Rx)
OUT 1
(Tx)
IN 1
(Rx)
OUT 0
(Tx)
GMR-01
IN 0
(Rx)
26 Sep 2003
GSM
Proceed as follows to connect fibre optic cables between master and expansion
cabinets in multiple cabinet sites:
1.
CAUTION
2.
At the master cabinet, connect the push-fit ST connectors of the fibre optic
cables to the IN 0 and OUT 0 ports on the site expansion board (see
Figure 2-45). Secure the cables in position by fitting strain relief clips to the
handles of the site expansion board.
3.
Route the fibre optic cables to the expansion cabinet, following existing
cable layout as far as possible.
4.
5.
68P02902W97-A
GMR-01
263
GPS connection
GSM
GPS connection
GPS connector location
The GPS connector is an optional item that can be supplied already fitted on the
site expansion board (see Figure 2-46). The connector is a 15-way D-type.
264
Pin
No
Signal/Description
Pin
No
Signal/Description
GPS power 1
GPS power 2
Not connected
10
Not connected
chassis earth
11
PPS positive
Tx negative
12
PPS negative
Tx positive
13
Rx positive
Rx negative
14
VPP
Earth
15
GPS return 2
GPS return 1
Installation & Configuration: Horizon II macro
68P02902W97-A
GMR-01
26 Sep 2003
GSM
Cable routeing
CAUTION
An adequate means should be provided for routeing cables from the main
power source to the equipment, such as a cable trough or conduit.
NOTE
68P02902W97-A
GMR-01
265
GSM
MAIN CABINET
EARTHING POINT
TOP PANEL TO
INTERFACE PANEL
EARTHING POINT
CABINET FRAME TO
INTERFACE PANEL
EARTHING POINT
DOOR TO CABINET
FRAME EARTHING POINT
ESP
CONNECTION
POINT
266
GMR-01
26 Sep 2003
GSM
Ensure the correct PSUs and PIM are fitted to match the
supply source voltage.
+27 V dc cabinets
To connect a +27 V dc (negative earth) cabinet to the main dc power source.
Observe the following rules:
S
48/60 V dc cabinets
To connect a 48/60 V dc (positive earth) cabinet to the main dc power source,
Motorola recommends using a 35 sq. mm dc input power cable with a maximum
length of 24 m. Observe the following rules:
S
+ 27 V dc connection procedure
To connect dc power cables to a + 27 V dc cabinet:
WARNING
1.
Route the earth wire from the building master earth and connect to the
main cabinet earth stud on the interface panel (see Figure 2-47). Tighten
to the correct torque (see Table 1-12 in Chapter 1).
WARNING
2.
Thread the cone-shaped plastic covers onto the cables before connection.
3.
Connect the black 0 volt (ve) dc power cable to the 0 V terminal on the
dc PIM (see Figure 2-48), and route to the main dc power source.
4.
Connect the red 27 volt (+ ve) dc power cable to the V IN terminal on the
dc PIM (see Figure 2-48), and route to the main dc power source.
5.
Tighten the dc power connections (M6 nuts on studs with flat washers) to
the correct torque as in step 1.
68P02902W97-A
GMR-01
267
GSM
1.
Route the earth wire from the building master earth and connect to the
main cabinet earth stud on the interface panel (see Figure 2-47). Tighten
to the correct torque (see Table 1-12 in Chapter 1).
WARNING
2.
Thread the cone-shaped plastic covers onto the cables before connection.
3.
Connect the black 0 volt (+ve) dc power cable to the 0 V terminal on the
dc PIM (see Figure 2-48), and route to the main dc power source
4.
Connect the blue 48/60 volt (ve) dc power cable to the V IN terminal on
the dc PIM (see Figure 2-48), and route to the main dc power source.
5.
Tighten the dc power terminal connections (M6 nuts on studs with flat
washers) to correct torque as in step 1.
0V
268
GMR-01
26 Sep 2003
GSM
The connection procedure for the 230 V ac cabinet is similar to those described
previously for the dc cabinets, except that the PIM has three input terminals
instead of two (see Figure 2-49).
WARNING
68P02902W97-A
GMR-01
269
GSM
PSUs in the cabinet are the correct type for the voltage selected.
Connecting dc power
To connect dc power to a cabinet:
WARNING
CAUTION
1.
2.
3.
Route and secure the dc power and earth cables from the cabinet to the
building power supply.
4.
5.
Connect the 0 V lead of the input dc power cable to the 0 V terminal of the
main dc power supply. See Installing and connecting power and earth
cabling.
6.
If required, ensure that all correct Request for connection and Completion
and inspection form certificates have been sent to the local electricity supply
board. Sample forms are provided in Chapter 4.
270
GMR-01
26 Sep 2003
GSM
Connecting ac power
WARNING
2.
Route and secure the ac power cable from the cabinet to the building ac
power supply.
3.
4.
If required, ensure that all correct Request for connection and Completion
and inspection form certificates have been sent to the local electricity supply
board. Sample forms are provided in Chapter 4.
68P02902W97-A
GMR-01
271
272
GSM
GMR-01
26 Sep 2003
Chapter 3
68P02902W97-A
GMR-01
31
GSM
32
GMR-01
26 Sep 2003
Introduction to interoperability
GSM
Introduction to interoperability
Mixed product sites
This chapter describes how the Horizon II macro can be used in conjunction
with other Motorola BTS products.
Different Motorola product types can be collocated at the same physical site
without restriction, provided they are configured as logically separate
installations, and in accordance with the normal product engineering rules.
When mixed product types are installed at the same logical site, a number of
technical issues arise that restrict the hardware that can be configured, and the
way it is interfaced. This chapter explains which product types can be mixed in
this way, and how they are interfaced.
Architectural constraints
To enable different product types to be used at the same logical site, one
product type is chosen as master, which is connected to the extender equipment
so that the two product types can function as a single, logical BTS. This
approach is viable when the product types to be interfaced have similar
architectures.
Motorola BTS product types that can be interfaced for collocation at a single
logical site are therefore restricted to those shown in Table 3-1 below.
Table 3-1 BTS compatibility for collocation at a single logical site
Master
Extender
InCell
InCell
n/a
No
No
No
No
M-Cell2
No
Yes*
Yes*
No
No
M-Cell6
No
No
Yes*
Yes
Yes
Horizonmacro
No
No
Yes*
Yes
Yes
Horizon II macro
No
No
Yes*
Yes
Yes
68P02902W97-A
GMR-01
33
GSM
34
GMR-01
26 Sep 2003
GSM
RF coupling
CTU2
HIISC
XMUX
Network termination
functions
Horizon II macro
RF coupling
CTU
FMUX
MCUF
FMUX
Network termination
functions
RF coupling
Horizonmacro
TCU
FOX
FMUX
MCU
Network termination
functions
M-Cell6
68P02902W97-A
GMR-01
35
GSM
Cross connections
RF coupling
RF coupling
(see text)
CTU
CTU2
HIISC
FMUX
XMUX
Network termination
functions
Horizonmacro (Slave)
Abis
Interface
OR
Cross connections
RF coupling
(see text)
RF coupling
TCU
CTU2
Fibre optic link
FMUX
FOX
XMUX
MCU
Network termination
functions
Abis Interface
Horizon II macro (Slave)
M-Cell6 (Master)
When two product types are interfaced in this way, the control function for the
entire site is implemented by the master BTS. In Figure 3-2, this is the
Horizon II macro or the M-Cell6. In practice, any Horizon II macro,
Horizonmacro or M-Cell6 BTS can be configured as master, depending on the
needs of the network concerned.
36
GMR-01
26 Sep 2003
GSM
Horizon II macro
Horizonmacro
Layout 2
Horizon II macro
Horizonmacro
Layout 3
Horizon II macro
M-Cell6
Horizonmacro
M-Cell6
M-Cell6
Technical issues
When mixing different BTS types, the interface may be required to resolve
some or all of the following issues, depending on the site configuration:
S
The interface must deliver both Rx and Rxdiv (receive diversity) signals to
each transceiver.
The interface must not change the uplink (receive) signal level delivered to
any transceiver.
Receive path
When a cell is wholly configured within one cabinet, there is no requirement to
connect the uplink or downlink RF signals between the master and slave
cabinets. The only interface between the cabinets in this type of mixed BTS
configuration is therefore at digital level, between XMUXs/FMUXs via the fibre
optic link.
When a cell is split between two cabinets, the uplink signals must be connected
between the cabinets since both Rx and Rxdiv signals are required at each
transceiver. In this situation the downlink signal may or may not require
connection between cabinets, depending on the site configuration.
The uplink connectivity requirements between different cabinets for DCS1800
and GSM900 are described on the following pages.
Installation & Configuration: Horizon II macro
26 Sep 2003
68P02902W97-A
GMR-01
37
GSM
DCS1800
Although this example describes connections between a
Horizon II macro cabinet and a M-Cell6 cabinet, it also
applies to connections between a Horizonmacro cabinet
and a M-Cell6 cabinet.
NOTE
Refer to Figure 3-4. In the Horizon II macro cabinet, low noise amplification in
the SURF2 module first boosts the Rx signal by +13 dB. Separate Rx outputs
from the SURF2 are then discretely routed to relevant transceivers in the master
M-Cell6 cabinet, and to the LNA. Since the LNA boosts the Rx signal by a
further +13 dB, a 13 dB attenuator is placed in the signal path to offset this
additional signal gain, which would otherwise result in signal levels outside the
permitted range for the transceivers.
The Rxdiv signal is similarly given a +13 dB boost by the LNA. Separate Rxdiv
outputs from the LNA are then discretely routed to relevant receivers in the
slave cabinet, and to the SURF2 module. Since the SURF2 provides a further
+13 dB boost, a 13 dB attenuator is again placed in the signal path to offset this
additional gain.
In this way, the arrangement shown in Figure 3-4 delivers Rx and Rxdiv signals
to the uplink path in both cabinets, at the required signal level.
Figure 3-4 Functional overview of the receive path for a DCS1800
split cell configuration
Cell B
Cell C
Rx
Rxdiv
Cell A
Rxdiv
Rx
Duplexer
Rx
Rxdiv
Duplexer
Rxdiv
13 dB
SURF2
+13 dB
13 dB
Rx
Rxdiv
LNA
Rx
Rx
CTU2
FMUX
FOX
MCU
GMR-01
Rxdiv
TCU
XMUX
38
+13 dB
26 Sep 2003
GSM
GSM900
In GSM900 products, RF gain for the SURF2 (Horizon II macro), SURF
(Horizonmacro) and IADU (M-Cell6) is configurable. A split cell configuration is
therefore dealt with in the same way as that described for DCS1800, except that
the 13 dB attennuators are not required. Instead, the required signal level is
maintained by using appropriate gain settings for the SURF2, SURF and IADU.
Transmit path
M-Cell6 combining
When configuring the downlink paths for a cell using three carriers or more, it
may be necessary to provide additional external RF load(s) for the combiners.
This is illustrated by Figure 3-5, which shows a typical M-Cell6 combining
arrangement for a 4-carrier cell.
Duplexer
External
load
HCOMB
3IP CBF
Hybrid
Load
Load
Hybrid
Carrier 1
Hybrid
Carrier 2
Carrier 3 Carrier 4
One carrier from each of four transceivers
68P02902W97-A
GMR-01
39
GSM
Horizonmacro combining
A similar arrangement is used in the Horizonmacro, which uses a Hybrid
Combiner Unit (HCU) and Dual stage Duplexed combining Filter (DDF), as
shown in Figure 3-6. The DDF has three input ports together with two internal
RF loads, and therefore does not require the addition of any external load.
Figure 3-6 Typical Horizonmacro arrangement for combining four carriers
Duplexer
Load
DDF
HCU
Hybrid
Load
Load
Hybrid
Hybrid
Carrier 1 Carrier 2
Carrier 3 Carrier 4
One carrier from each of four transceivers
DUP
Load
DHU
HCU
Duplexer
Hybrid
Load
Load
Hybrid
Carrier 1
Hybrid
Carrier 2
Carrier 3
Carrier 4
One carrier from each of four transceivers (GSM/EDGE single carrier mode)
Two carriers from each of four transceivers (GSM dual carrier mode)
310
GMR-01
26 Sep 2003
GSM
Sector 3
2B
1B
0B
0A
1A
Sector 1
2A
DUP
HCU FTHRU
RX
Load
3IP CBF 2
ANT
3IP CBF 1
HCOMB
10/11
8/9
6/7
Load
Horizon II macro
M-Cell6
Inputs to the 3IP CBF1 are carriers 0 and 1, together with the combined output
of the HCOMB. 3IP CBF1 contains a single load and is therefore connected to
the external load mounted on the HCOMB. Inputs for the 3IP CBF2 are carriers
4 and 5, together with carriers 6 and 7 from the double density CTU2 in the
Horizon II macro cabinet (via the feedthrough plate). The 3IP CBF2 contains a
single load and therefore requires the addition of an external 50 ohm load, as
shown. Carriers 8/9 and 10/11 are combined in the Horizon II macro HCU and
are then fed to the single duplexer.
68P02902W97-A
GMR-01
311
GSM
Horizonmacro
900/1800
M-Cell6 900
M-Cell6 1800
DUP
(no equivalent)
Duplexer
Duplexer
HCU
HCU
Hybrid
Hybrid
CBF*
3-input CBF*
DHU
(no equivalent)
3-input
Feedthrough plate
Feedthrough
plate
Non-hybrid
(no equivalent)
HCU + DUP
DCF
CBF + duplexer
Hybrid + duplexer
DHU + DUP
DDF
3-input CBF* +
duplexer
2 x hybrid +
dup/BPF
2 x DUP
TDF
TBF + duplexer
2 x dup/BPF
(no equivalent)
(no equivalent)
(no equivalent)
SURF2
SURF
3 x DLNB + IADU
3 x LNA
Split sector
cable
Rx extender
(no equivalent)
312
Based on the required site configuration (for example, 4/4/4), use the
functional guidelines provided in this chapter to decide the most effective
hardware configuration for the additional cabinet(s).
Configuration diagrams and product ordering help are available from the
Motorola local office.
GMR-01
26 Sep 2003
GSM
RX
2B
RX
1B
RX
0B
SECTOR 2
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
2B 1B
0B 2A
1A 0A
EXT
RX
DCF
DCF
RX
ANT
ANT
BLANK
BLANK
DUP
BLANK
BLANK
DUP
EMPTY
EMPTY
CTU2
EMPTY
EMPTY
CTU2
BLANK
SITE EXPANSION
BOARD
HIISC
Horizon II macro
master cabinet
0
FMUX
Horizonmacro
slave cabinet
Fibre Optic Link (x2)
68P02902W97-A
GMR-01
313
GSM
RX
2B
RX
1B
RX
0B
SECTOR 2
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
2B 1B
0B 2A
1A 0A
EXT
4
HCU
RX
HCU
ANT
BLANK
DDF
FTHRU
DDF
RX
ANT
DUP
BLANK
CTU2
EMPTY
DUP
LOAD
EMPTY
EMPTY
SITE EXPANSION
BOARD
CTU2
CTU2
HIISC
Horizon II macro
master cabinet
0
FMUX
Horizonmacro
slave cabinet
Fibre Optic Link (x2)
314
GMR-01
26 Sep 2003
GSM
RX
2B
RX
1B
RX
0B
SECTOR 3
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
SECTOR 2
2B 1B
0B 2A
1A 0A
EXT
BLANK
DCF
DCF
RX
ANT
BLANK
BLANK
BLANK
BLANK
BLANK
DUP
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
CTU2
SITE EXPANSION
BOARD
HIISC
Horizon II macro
master cabinet
0
FMUX
Horizonmacro
slave cabinet
Fibre Optic Link (x2)
68P02902W97-A
GMR-01
315
GSM
RX
2B
RX
1B
RX
0B
SECTOR 1
SECTOR 2
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
2B 1B
0B 2A
1A 0A
EXT
BLANK
DCF
DCF
RX
ANT
BLANK
BLANK
BLANK
BLANK
BLANK
DUP
EMPTY
EMPTY
EMPTY
EMPTY
EMPTY
CTU2
SITE EXPANSION
BOARD
XMUX
Horizon II macro
slave cabinet
0
MCUF
Horizonmacro
master cabinet
Fibre Optic Link (x2)
316
GMR-01
26 Sep 2003
GSM
RX
2B
SECTOR 3
SECTOR 1
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
2B 1B
0B 2A
1A 0A
EXT
5
RX
RX
RX
ANT
ANT
ANT
ANT
DUP
DUP
BLANK
DUP
DUP
EMPTY
CTU2
CTU2
EMPTY
CTU2
CTU2
SITE EXPANSION
BOARD
DCF
DCF
RX
BLANK
BLANK
HIISC
Horizon II macro
master cabinet
0
FMUX
Horizonmacro
slave cabinet
Fibre Optic Link (x2)
68P02902W97-A
GMR-01
317
GSM
RX
2B
SECTOR 1
RX
1B
RX
0B
EXP EXP
B
A
RX
0A
RX
1A
RX
2A
SECTOR 3
2B 1B
0B 2A
1A 0A
EXT
DHU
RX
CTU2
CTU2
DDF
DDF
ANT
DUP
BLANK
CTU2
CTU2
FTHRU
RX
ANT
BLANK
DHU
SITE EXPANSION
BOARD
DUP
CTU2
CTU2
HIISC
Horizon II macro
master cabinet
0
FMUX
Horizonmacro
slave cabinet
Fibre Optic Link (x2)
318
GMR-01
26 Sep 2003
GSM
2B
1B
0B
Branch 1
2A
1A
0A EXT EXT
B
A
SURF
B
CTU2
Rx D
Rx A
Rx C
Rx B
NOTE
Branch 1 (main)
LPBK / VSWR
Branch 2 (diversity)
The physical interface between the CTU2 and the SURF consists of three
connections, one bi-directional and two directional. The bi-directional connection
is for the RF receive main branch (branch 1) and for digital communication
between the SURF and the CTU2. One directional connection is for the RF
receive diversity branch (branch 2), and the other is for the loopback or VSWR
mode selection and the LPBK / VSWR signal.
Figure 3-16 shows an example of a configuration with CTU2s (operating in
single density mode) installed in a Horizonmacro cabinet.
68P02902W97-A
GMR-01
319
GSM
SECTOR 3
2B 1B
0B 2A
1A
SECTOR 1
0A
EXT
DCF
DCF
DCF
CTU2 CTU2
0
MCUF
320
CCBs are not supported when CTU2s are used in Horizonmacro indoor
BTSs.
RF output power from the CTU2s is reduced (see Table 1-8 in Chapter 1).
GMR-01
26 Sep 2003
GSM
The mounting plate is located as shown in Figure 3-18 in place of the original
blanking plate fitted to the M-Cell6.
Figure 3-18 Location of the snap-in multi cable gland and mounting plate
in the M-Cell6
MULTI CABLE
GLAND
M-Cell6 CABINETS
68P02902W97-A
GMR-01
321
322
GSM
GMR-01
26 Sep 2003
Chapter 4
Commissioning the
Horizon II macro
68P02902W97-A
GMR-01
41
GSM
42
GMR-01
26 Sep 2003
GSM
Pre-power up checks.
PIN NUMBER
4
6
7
8
4 m SCREENED CABLE
9-WAY D-TYPE
CTU2/HIISC CONNECTOR
9-WAY D-TYPE
PC COMMUNICATIONS PORT
68P02902W97-A
GMR-01
43
GSM
Test equipment
Table 4-1 provides details of the test equipment required to perform the
commissioning procedures in this chapter.
Table 4-1 Test equipment required for commissioning
Quantity
44
Description
Comments
PAT tester
GMR-01
26 Sep 2003
Pre-power up checks
GSM
Pre-power up checks
Overview of pre-power up checks
WARNING
This section contains procedures for testing the power system prior to applying
power to the cabinet.
WARNING
CAUTION
68P02902W97-A
GMR-01
45
Pre-power up checks
GSM
Visual inspection
Inspect the installation for damage in accordance with BS 7671 (16th Edition
<Section 712>) or the IEC 364 equivalent.
WARNING
Cabinet exterior
Examine the exterior of the cabinet for structural, paint or mechanical damage
and report any damage to Motorola.
Cabinet interior
Examine the interior of the cabinet for structural, paint or mechanical damage
and report any damage to Motorola.
Power equipment
Examine the power equipment for mechanical damage and report any damage
to Motorola.
46
GMR-01
26 Sep 2003
Pre-power up checks
GSM
Antenna feeders.
AC distribution board.
AC supply isolator.
NOTE
Rack members.
Check that the measured resistance is less than 0.1 ohm with the tester
connected to a conductive surface (bare metal) at extreme ends of the earth
cables.
On completion of each earth check apply conductive non-oxidizing grease to the
earth connections on the earth busbar.
AC test voltage
(volts)
Minimum insulation
(megohms)
500
0.5
When the test has been completed, sign the completion and inspection
certificate, a sample of which may be found in Sample form 2.
68P02902W97-A
GMR-01
47
GSM
48
1.
2.
3.
If fitted, remove the optional compact flash card from its slot in the HIISC.
4.
5.
Set all buttons on the circuit breaker card to the out (off) position.
GMR-01
26 Sep 2003
GSM
2.
Set each PSU switch to the OUTPUT ENABLE position; check that each
PSU has the active (green) LED on and the alarm (red) LED off.
3.
Press the FAN circuit breaker button. Check that each fan module is
operating correctly.
4.
5.
6.
Press the SC0 circuit breaker button. Also press the SC1 button if a
redundant HIISC is installed. Check that the HIISC LEDs operate
correctly; green LEDs lit and red LEDs off.
NOTE
Both red and green LEDs are initially lit while the unit
conducts a self test. After approximately 20 seconds, the
red LED will extinguish, indicating normal condition.
Press the appropriate CBC circuit breaker buttons for the installed CTU2s,
and check that the RADIO STATUS LED for each CTU2 flashes green.
8.
This completes the power up procedure for the cabinet without code load.
68P02902W97-A
GMR-01
49
GSM
2.
Insert the (optional) compact flash card into the slot on the master HIISC.
3.
Connect the 9 to 9-way cable from the PC serial A port to the HIISC TTY
port.
4.
5.
6.
7.
410
1.
2.
Turn each PSU switch to the OUTPUT ENABLE position; check that each
PSU has the active (green) LED on and the alarm (red) LED off.
3.
Press the FAN circuit breaker button. Check that each fan module is
operating correctly.
4.
5.
GMR-01
26 Sep 2003
GSM
6.
Press the SC0 circuit breaker button. Also press the SC1 button if a
redundant HIISC is installed. Check that the HIISC LEDs operate
correctly; green LEDs lit and red LEDs off.
HIISC initialization will commence at power up. A connection to the BSC
will be established and code download will take place. After download the
site will be initialized.
7.
NOTE
Both red and green LEDs are initially lit while the unit
conducts a self test. When rebooting due to a code
download, the red LED extinguishes after approximately
50 seconds.
CAUTION
Press the appropriate CBC circuit breaker buttons for the installed CTU2s,
and check that the RADIO STATUS LED for each CTU2 flashes green.
At this point, after the HIISC has initialized, the CTU2s will download code
from the HIISC.
CAUTION
8.
Once fully initialized, all CTU2s should have RADIO STATUS LED solid
green, and TRANSMIT STATUS LEDs either off or solid yellow.
9.
10.
This completes the power up procedure for the cabinet with code load.
68P02902W97-A
GMR-01
411
GSM
Figure 4-2 Cabinet showing power up modules and detailed view of CBC
CBC
FRONT PANEL
CTU0 (25 A)
CTU1 (25 A)
PSUs
CIRCUIT
BREAKER CARD
(CBC)
CTU2 (25 A)
CTU3 (25 A)
CTU4 (25 A)
CTU5 (25 A)
DUP (1 A)
SC0 (2 A)
SC1 (2 A)
SURF0 (1 A)
SURF1 (1 A)
FAN (10 A)
CTU5
CABINET
DOOR ALARM
SWITCH
412
GMR-01
CTU0
MASTER
HIISC
26 Sep 2003
Cabinet shutdown
GSM
Cabinet shutdown
Shutdown procedure
To shut down the cabinet, power it down as follows:
1.
2.
3.
68P02902W97-A
GMR-01
413
GSM
Address
......................................................................................................................................
........................................................................................
DETAILS OF INSTALLATION
The installation to be connected is :
tick as appropriate
A rewire
An alteration
TYPE OF EQUIPMENT
Cooker
Water heater
Storage radiators
Other list below
NO OF PHASES
Cable Sheath
RCD
Other
Other
Give Details
Give Details
DECLARATION
The electrical installation, summarised above, complies with the current edition of the Regulations for Electrical
Installations published by the Institution of Electrical Engineers and is now ready for connection to xxxxxxxxx
Electrics supply network.
It is understood that xxxxxxxxxx Electric will carry out tests, required by law, prior to connection, but these tests
will NOT confirm that the installation complies with the IEE Wiring Regulations, NOR will its connection imply
that it is approved by xxxxxxxxxx Electric in any way.
............................................................................................................
........................................................................................................................................
...........................................................................................
Signed
414
................................................................................ Date
...............................................
GMR-01
26 Sep 2003
GSM
TNC
Earth Electrode
Resistance . . . . . . . . . . . . . . . ohms
TNS
TNCS TT
Method of Measurement
IT
.............................................
......
Number of phases . . . . . . . . . . . . . . . . . .
ascertained
by
enquiry
Prospective shortcircuit current
Earth fault loop impedance (Ze)
determined
by
calculation
measured
. . . . . . . . . . . . . . . . . . . . . . . kA
. . . . . . . . . . . . . . . . . . . . . . . . ohms
........................
Rating . . . . . . . . A
Rating . . . . . . . . A No of poles . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . mA.)
(Describe) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
pages
Details of departures (if any) from the Wiring Regulations (12004, 12005) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
68P02902W97-A
GMR-01
415
GSM
DESIGN
I/We being the person(s) responsible (as indicated by my/our signatures below) for the Design of the electrical installation, particulars of which
are described on Page 3 of this form CERTIFY that the said work for which I/we have been responsible is to the best of my/our knowledge and
belief in accordance with the Regulations for Electrical Installations published by the Institution of Electrical Engineers, 16th Edition, amended
to (3.) (date . . . . . . . . .) except for the departures, if any, stated in this Certificate.
The extent of liability of the signatory is limited to the work described above as the subject of this Certificate.
For the DESIGN of the installation:
Name (In block Letters):
Position:
(3.) Date
CONSTRUCTION
I / We being the person(s) responsible ( as indicated by my/our signatures below ) for the Construction of the electrical installation, particulars of
which are described on Page 3 of this form CERTIFY that the said work for which I/we have been responsible is to the best of my/our knowledge
and belief in accordance with the Regulations for Electrical Installations published by the Institution of Electrical Engineers, 16th Edition,
amended to (3.) (date . . . . . . . . .) except for the departures, if any, stated in this Certificate.
The extent of liability of the signatory is limited to the work described above as the subject of this Certificate.
For the CONSTRUCTION of the installation:
Name (In block Letters):
Position:
(3.) Date
Position:
(3.) Date
(6) page 1 of . . . . pages
416
GMR-01
26 Sep 2003
GSM
1.
This document is intended for the initial certification of a new installation or of an alteration or addition to
an existing installation and of an inspection.
2.
The signatures appended are those of the persons authorised by the companies executing the work of
design, construction and inspection and testing respectively. A signatory authorised to certify more than
one category of work shall sign in each of the appropriate places.
3.
Dates to be inserted.
4.
Where particulars of the installation recorded herein constitute a sufficient schedule for the purpose of
Regulation 5140901 further drawings / schedules need not be provided. For other installations the
additional drawings/schedules listed below apply.
5.
Insert here the time interval recommended between periodic inspections. Regard should be paid to
relevant National or Local legislation and reference should be made to chapter 13.
6.
The page numbers of each sheet should be indicated together with the total number of sheets involved.
(4) Schedule of additional records.
68P02902W97-A
GMR-01
417
418
GMR-01
GSM
26 Sep 2003
Chapter 5
Decommissioning the
Horizon II macro
68P02902W97-A
GMR-01
51
GSM
52
GMR-01
26 Sep 2003
GSM
Read all the earlier chapters of this manual, before attempting to decommission
a Horizon II macro cabinet.
Contact the OMC-R and ensure the cabinet is taken out of service.
Open the cabinet door and power down the cabinet, as described in
Powering down the cabinet in this section.
Ensure any unused items, such as hood pins, have been retrieved from
storage elsewhere.
2.
3.
26 Sep 2003
68P02902W97-A
GMR-01
53
GSM
2.
3.
4.
Disconnect the ac or dc input power cables from the cabinet top panel.
5.
6.
If the power cable is not to be used again for other equipment, dispose of
safely.
54
1.
2.
3.
Disconnect fibre optic cables between main cabinet and any expansion
cabinets.
4.
5.
6.
If the cables are not to be used again for other equipment, dispose of
them safely.
GMR-01
26 Sep 2003
GSM
For the subsequent use of eyebolts, there may be local regulations that govern
the use of lifting equipment and stipulate a test and/or examination regime. If
the eyebolts are to be used, ensure that all such regulations are met.
Eyebolts can be fitted into the four designated cabinet top panel locations,
shown in Figure 5-1, after removal of the screws. These locations are identified
with an eyebolt symbol and the word LIFT. The eyebolt locations are also used
for stacking bracket attachment.
68P02902W97-A
GMR-01
55
GSM
Fit eyebolts to the locations, identified with an eyebolt symbol and the
word LIFT. Attach eyebolts to suitable lifting equipment.
WARNING
56
2.
Remove the four bolts holding upper cabinet plinth to the stacking bracket.
3.
Lift upper cabinet, complete with plinth, off the stacking bracket, and lower
to the floor.
4.
Remove the two M10 bolts securing the plinth to the cabinet, and slide
apart.
5.
Pack the upper cabinet and plinth in separate containers, for storage,
transport or safe disposal.
GMR-01
26 Sep 2003
GSM
EYEBOLT
POSITIONS
68P02902W97-A
GMR-01
57
GSM
Apply gentle
pressure
Apply gentle
pressure
2.
Loosen and remove the eight M8 screws holding the stacking bracket to
the cabinet top, and retain.
WARNING
3.
4.
Fit the eight previously removed M8 screws to the correct cabinet screw
points (see Figure 2-5 in Chapter 2). Tighten to the correct torque (see
Table 1-12 in Chapter 1).
5.
Place the stacking bracket in a box for storage, transport or safe disposal.
58
GMR-01
26 Sep 2003
GSM
Unscrew the two front bolts that secure the cabinet to the plinth.
2.
3.
Unscrew the plinth anchor bolts and lift the plinth from the floor.
4.
5.
Pack the cabinet and plinth in separate containers, for storage, transport
or safe disposal.
68P02902W97-A
GMR-01
59
GSM
____________________________
Yes
No
N/A
510
GMR-01
26 Sep 2003
Index
68P02902W97-A
GMR-01
I1
GSM
I2
GMR-01
26 Sep 2003
GSM
AC power
connection, 271
connection procedure, 269
DC power
connection, 270
connection procedure, 267
Decommissioning, 53
cable disconnection, 54
checklist, 510
removal of floor mounted cabinet, 59
upper cabinet in stacked configuration, 56
B
Battery backup, optional BBS, 18
BBS, alarm cable connection, 255
Dimensions
cabinet, 111
indoor cabinet, 113
E
E1/T1, testing, 25
Cabinet
dimensions, 113
installing on stacking bracket, 216
lifting, 217, 55
mounting on plinth, 211
power down, 413
separating from crate base, 28
stacked assembly view, 219
weight, 111
Cable routeing, 265
Cables, SURF/Tx interconnecting, 222
Cabling, power and earth, 265
CIM, pinouts, 257
Earth
cabling, 265
continuity check, 47
Earthing, site, 220
Earthing points, cabinet, 266
ESP, connection point, 266
External alarms, shorting plug, 255
External alarms connector, pinouts, 255
Eyebolt
attachment points, 216
positions, 55
safety, 217, 55
F
feature
references, 3
tag format, 3
Fibre optic cables, 260
connections between cabinets, 263
Connecting power
ac, 271
dc, 270
CTU2
compatibility with Horizonmacro, 319
TTY adapter, 43
CTU2 slot, valid factory calibration, 28
Forms
Completion/inspection sample, 416
connection sample, 414
Frequency band characteristics, 112
Frequency hopping, 112
68P02902W97-A
GMR-01
I3
GSM
H
HIISC to PC, cable pin outs, 43
Hood, installation, 212
Horizon II macro, interoperability, 33
R
Redundancy, 260
RF
S
Sensitivity, Rx performance, 110
Shutdown, cabinet, 413
Site expansion board, 262
Software requirements, 17
M
MCell6, Horizon II macro and Horizonmacro
hardware equivalents, 312
Mixed cabinets, special hardware, 321
Plinth
installation, 29
mounting the cabinet, 211
Power
cabling, 265
consumption, 18
supply requirements, 18
I4
Type approval, 17
GMR-01
26 Sep 2003
GSM
U
Unpacking, 26
W
Weight, cabinet, 111
68P02902W97-A
GMR-01
I5
GSM
I6
GMR-01
26 Sep 2003