Beruflich Dokumente
Kultur Dokumente
Catalog
8501CT0502R07/13
2013
Class 8501
Table of Contents
Product Description................................................................................................................................ 5
Measurement Signals for Thermocouples and Pt100 Probes ......................................................... 5
The Zelio Analog Range .................................................................................................................. 5
Converters for J and K Type Thermocouples .................................................................................. 6
Converters for Universal Pt100 Probes ........................................................................................... 6
Converters for Optimum Pt100 Probes ........................................................................................... 6
Universal Voltage/Current Converters ............................................................................................. 7
Description ....................................................................................................................................... 7
Specifications and Characteristics ......................................................................................................... 8
Selection ..............................................................................................................................................10
Dimensions, Mounting Instructions, Wiring Diagrams..........................................................................12
Catalog Number Index .........................................................................................................................13
4
11/2013
Product Description
The Zelio Analog range of converters is designed to convert signals emitted by sensors or electrical
measurement devices, into standard electrical signals that are compatible with automation platforms
and controllers (thermal processes, speed, etc.). They also allow the connection distance between a
sensor and a measurement acquisition device to be increased, for example, between a thermocouple
and a programmable controller.
These converters are suitable for universal use, as they are UL listed, CSA certified, and conform to
IEC standards.
420 mA current loops transmitted over a long distance are less sensitive to interference than low
level voltage signals from sensors,
5
11/2013
Thermocouples, which consist of two metals with different thermoelectric characteristics, produce a
voltage that varies according to temperature. This voltage is transmitted to the Zelio Analog converter,
which converts it to a standard signal.
Converters for thermocouples have cold junction compensation to allow detection of measurement
errors induced by the connection to the device itself.
Converters for J and K type thermocouples have:
RMTJ40BD
RMTK90BD
109000
Pt100 probes with platinum resistors are electrical conductors whose resistance varies according to
the temperature. This ohmic resistance is transmitted to the Zelio Analog converter, which converts it
to a standard signal.
Converters for Universal Pt100 probes have:
RMPT70BD
32482 F (0 to 250 C)
32932 F (0 to 500 C)
The products in the Universal Pt100 family allow wiring of Pt100 probes in 2, 3, and 4-wire mode.
for inputs, a pre-set temperature range identical to that of converters for Universal Pt100 probes
for outputs, 010 V signal dedicated to Zelio Logic analog inputs
6
11/2013
109002
RMCA61BD
Description
108998
Zelio Analog converters have the following on their front panel, depending
on the model:
1. Two terminals for 24 Vdc supply connection
1
2. A Power ON LED
3. Three input selector switches (depending on model)
4
5
6
7
RMCL55BD
7
11/2013
Conforming to Standards
IEC 60947-1, IEC 60584-1 (IEC 60751, DIN 43760 for RMP)
Product Certifications
UL Listed, File E164353 NKCR; CSA Certified, File 089150_S_000, Class 3211-07;
; GL
Degree of Protection
Housing
IP 50
Terminal block
IP 20
Flame Resistance
Shock Resistance
Vibration Resistance
Immunity to EMC
Resistance to electrostatic
discharge
Disturbance
Surge withstand
Radiated/conducted
-40185 F (-4085 C)
Operation
Degree of Pollution
Mounting
Connection
2-16 AWG or 1-14 AWG wire (2 x 1.5 mm2 or 1 x 2.5 mm2 cable)
Tightening Torque
Specific Characteristics
Types of converter for thermocouples
Input Types
RMTJ40BD
J (Fe-CuNi)
Temperature range
32302 F
0150 C
RMTJ60BD
RMTJ80BD
RMTK80BD
RMTK90BD
K (Ni-CrNi)
32572 F
0300 C
321112 F
0600 C
321112 F
0600 C
322192 F
01200 C
Range
100 k
Range
010 V
500
Reverse polarity, Overvoltage ( 30 V) and Short-circuit
Supply
Voltage
Rated
Maximum current
consumption
40 mA
60 mA
Built-in protection
Reverse polarity
Signalling
Measurements
1% of the full scale value
10% of the full-scale value (in an environment subject to electromagnetic
interference of 10 V/m)
Accuracy
At 68 F (20 C)
Repeat accuracy
At 68 F (20 C)
At 140 F (60 C)
Temperature coefficient
8
11/2013
Analog Output
Output selection
Voltage
Current
Built-in protection
Diagnostics
Supply
Voltage
Maximum current
consumption
Built-in protection
Signalling
Measurements
RMPT10/13BD
Probe type
Temperature range
Rated
For voltage output
For current output
At 68 F (20 C)
Repeat accuracy
At 68 F (20 C)
At 140 F (60 C)
32932 F
0500 C
200 mW
RMCN22BD
RMCL55BD
RMCV60BD
Voltage
010 Vdc
Current
420 mA
050; 0300;
010, 10 Vdc
0500 DC or AC
50/60 Hz
020 mA ; 420 mA
Range
Minimum impedance of load
Range
Maximum impedance of load
Built-in protection
Diagnostics
32482 F
0250 C
RMPT70/73BD
Voltage/Current Converters
Current
RMPT50/53BD
Temperature coefficient
Connection in 2-wire mode
Analog Output
Output selection
Voltage
RMPT30/33BD
Accuracy
Input Types
RMPT20/23BD
RMCA61BD
By wiring
Switchable
Switchable
By wiring
010 V
010 V; 10
010 V
010 V
100 kW
420 mA
020 mA ; 420 mA 020 mA ; 420 mA 020 mA ; 420 mA
500 W
Reverse polarity, overvoltage ( 30 V) and short-circuit
Output predetermined according to type of output selected:
voltage:
<0V
voltage:
- 1010 V: -10 V
010 V: 0 V
voltage:
<0V
current:
< 4 mA
current:
020 mA: 0 mA
420 mA: 4 mA
current:
020 mA: 0 mA
420 mA: < 4 mA
Supply
Voltage
Maximum current
consumption
Built-in protection
Signalling
Measurements
Rated
For voltage output
For current output
Accuracy
At 68 F (20 C)
Repeat accuracy
At 68 F (20 C)
At 140 F (60 C)
Temperature coefficient
24 Vdc 20%
24 Vdc 20% isolated (1.5 kV)
non-isolated
40 mA
70 mA
60 mA
90 mA
Reverse polarity
Green LED (power on)
1% of the full scale value
10% of the full-scale value (in an
environment subject to electromagnetic
interference of 10 V/m)
0.2% of the full scale value
0.6% of the full scale value
9
11/2013
Selection
Converters for J and K Type ThermocouplesSupply voltage 24 Vdc 20%, non-isolated
Type
Type J
Switchable Output
Signals
Catalog Number
Weight
lb
kg
32302
0150
RMTJ40BD
0.264
0.120
32572
0300
RMTJ60BD
0.264
0.120
321112
0600
RMTJ80BD
0.264
0.120
321112
0600
RMTK80BD
0.264
0.120
322192
01200
RMTK90BD
0.264
0.120
108997
108999
Type K
Temperature Range
RMTJ40BD
RMTK90BD
109000
Pt100
2-wire, 3-wire, and
4-wire
Temperature Range
F
Switchable Output
Signals
Catalog Number
Weight
lb
kg
- 40104
- 4040
RMPT10BD
0.264
0.120
- 148212
- 100100
RMPT20BD
0.264
0.120
32212
0100
RMPT30BD
0.264
0.120
32482
0250
RMPT50BD
0.264
0.120
32932
0500
RMPT70BD
0.264
0.120
RMPT70BD
109001
Converters for Optimum Pt100 Probes (1)Supply voltage 24 Vdc 20%, non-isolated
Type
Pt100
2-wire, 3-wire, and
4-wire
RMPT13BD
Temperature Range
F
Switchable Output
Signals
Catalog Number
Weight
lb
kg
- 40104
- 4040
010 V or 420 mA
RMPT13BD
0.264
0.120
- 148212
- 100100
010 V or 420 mA
RMPT23BD
0.264
0.120
32212
0100
010 V or 420 mA
RMPT33BD
0.264
0.120
32482
0250
010 V or 420 mA
RMPT53BD
0.264
0.120
32932
0500
010 V or 420 mA
RMPT73BD
0.264
0.120
10
11/2013
Input signal
010 V or 420 mA
010 V or 420 mA
010 V, 10 V,
020 mA, 420 mA
Switchable:
01.5 A, 05 A, 015 A
DC or AC, 50/60 Hz
lb
kg
RMCN22BD
0.264
0.120
RMCL55BD
0.264
0.120
RMCV60BD
0.264
0.120
RMCA61BD
0.264
0.120
RMCN22BD
109002
108998
108996
Weight
Switchable:
010 V, 10 V,
020 mA, 420 mA
Supply voltage 24 Vdc 20%,
isolated
Catalog
Number
Output signal
RMCL55BD
RMCA61BD
Connection Accessories
Description
Terminal blocks for connection of protective
ground conductor
Type
Sold in lots of
Catalog
Number
Weight
oz
Screw
100
NSYTRV62PE
0.88
25.0
Spring
100
NSYTRV43PE
0.52
14.7
11
11/2013
(1)
Panel mounting
2x4
3.54 (90)
3.07 (78)
(1)
3.07 (78)
3.15 (80)
RMCA61BD
1.77 (45)
.99 (25)
3.56 (90.5)
3.56
(90.5)
2.01 (51)
1.22 (31)
3.27
(83)
Dimensions = In. (mm)
Wiring Diagrams
RMTJ, RMTK
RMPT0BD
RMPT3BD
2 mA
2 mA
1930 Vdc
IP1
Type
J or K
A1
(+) IP2
() IP1
A2
Vo
Vo
IP2
IP3
IP4
0 Vdc
IP2
IP3
IP4
OPG
A2
OPG
1930 Vdc
IP1
A1
A1
1930 Vdc
(1)
(1)
OPG
A2
0 Vdc
Vo
Io
0 Vdc
3-wire type
RL1 = RL2 = RL3; RL1 + RL2 200
RL1
IP1
IP2
IP3
IP3
RL2
IP4
RL2
IP4
IP4
RL3
IP3
RL1
IP1
RMCN22BD
RMCV60BD
RMCL55BD
A1
Ii
IPG
420 mA
Vo
1930 Vdc
(1)
OPG
A2
V
0 Vdc
1930 Vdc
A1
Vi
IPG
0 Vdc
Vi
(1)
Vo
Ii
OPG
IPG
A2
1930 Vdc
(1)
(1)
(1)
0 Vdc
V1
V2
V3
IPG
Vo
OPG
Io
A1
A2
A1
1930 Vdc
010 V
IP1
IP2
IP2
RL2
4-wire type
RL1 + RL2 200
OPG
A2
0 Vdc
RMCA61BD
A1
1930 Vdc
(1)
(1)
(1)
A2
0 Vdc
I1
I2
I3
Icom
Vo
Io1
Io2
OPG
(2)
(2)
(2)
The input, output, and power supply lines must be kept away from the power cables to
avoid effects due to induced interference.
The input and output cables must be shielded as indicated in the wiring diagrams and must be
kept away from each other.
12
11/2013
13
11/2013
11/2013