Chapter 5
Air
Conditioning
System
Control Humidity
An air
conditioner is an
appliance, system,
or mechanism designed to extract heat from an area using
a refrigeration cycle. In construction, a complete system of
heating, ventilation and air conditioning is referred to as
HVAC".
Other definition
Air conditioning is the process to control and
maintenance the air in space or enclosed areas.
Mechanical treatments performed on the
temperature, humidity, air renewal, cleanliness
and distribution of air to achieve the requirements
and functions of an item.
Air Conditioning is the process of treating air in an
internal environment to establish and maintain
requirement standards of temperature, humidity,
cleanliness, and motion.
The major pieces of equipment required to complete the airconditioning cycle are listed as follows:
fan
supply ducts
supply outlets
space to be conditioned
return outlets
return ducts
filter
heating coil (combustion chamber) or cooling coil
10
11
The Fan
The fan moves air to and from an enclosed space. In an airconditioning system, fan moves air that consists of:
The fan pulls air from the outdoor and from the room at the same time.
Since drafts in the room cause discomfort, and poor air movement
slows the body heat rejection process, it is necessary to regulate the
amount of air supplied by the fan. To accomplish this regulation a fan is
selected that can deliver the correct amount of air. By controlling the
speed of the fan, the air stream in the room can be regulated to
provide good circulation without drafts.
12
13
Supply Duct
14
Supply Outlets
Supply outlets help to distribute the air evenly in a room. Some outlets
fan the air and other outlets direct the air in a jet stream. Still other
outlets combine these actions.
As a result of these actions, the outlets are able to exert some control
on the direction of the air delivered by the fan. This directional
control plus the location and the number of outlets in the room
contribute greatly to the comfort or discomfort resulting from the air
pattern.
Room Space
15
Return Outlets
As stated previously, return outlets allow room air to enter the
return duct. The main function of the return outlet is to allow air
to pass from the room. These outlets are usually located on the
opposite wall from the supply outlet. For example, if the supply
duct is on the ceiling, or on the wall near the ceiling, then the
return duct may be located on the floor or on the wall near
the floor.
This situation is not true in all installations, however. Some systems
are provided with both the supply and the return near the
floor or near the ceiling.
16
Filters
Filters clean the air by removing dust, suspended particles, contaminants and
odours. Filters are located within the return air duct. These devices are made
of many materials including spun glass and composition plastic.
Other filter materials maintain an electrostatic charge, and attract and capture
dust and dirt particles from the air flowing through them.
There are 4 classification for filters:
i.
Dry
ii.
Viscous
iii.
Electrostatic
Electrostatic Filteriv.
Activated Carbon
very expensive,
extremely efficient
of removing fine
particles, pollens,
smoke.
17
1.
2.
3.
4.
5.
6.
Performance requirements
On comfort, noise, control options, flexibility and meeting
requirements of local regulations/codes
Capacity requirements
Range of capacity, multiple units, zoning, etc.
Spatial requirement
Plant room space, space for ducting and piping (vertical
shafts),
space for terminal equipment
Costs
Initial cost, operating cost and maintenance cost
Energy consumption
For both economic and environment reasons
System qualities
Aesthetics, life, reliability and maintainability
18
AC system
Window Unit
Air cooling
Package Unit
Water cooling
Split unit
Centralized system
Plant system
Air Handling unit
19
20
A. Unit systems
i)
Split system
In split system, the condenser and compressor are
located
in an outdoor unit but the evaporator
is located inside the
building.
Typically, the evaporator is mounted in the air
handler unit.
ii)
Packaged System
In a packaged system, as the name suggests, all
components the condenser, the compressor
and the
evaporator are located in a single
outdoor unit.
The entire unit is generally located on the ground
or on the roof.
Packaged systems are generally used when there
is limited space.
21
A split air conditioner splits the hot side from the cold
side system, like this:
22
23
24
25
26
27
1.
2.
3.
4.
5.
28
1.
2.
3.
4.
29
A/C
E ion purifying air system
Econavi
30
31
32
33
34