Sie sind auf Seite 1von 2

Entry-ID: 21927773

With what are SIMATIC WinCC V7.x, V 6.x and V5.x compatible?

WinCC Version
Software

Microsoft Windows
(32-Bit) *11)

Microsoft Internet Explorer

Virus Scanner

Remote Software

OPC

WinCC Smart Tools

V6.0
V6.0 SP1
V6.0 SP2
V6.0 SP3
V6.0 SP4
Client /
Client /
Client /
Client /
Client /
Server
Server
Server
Server
Server
Singlestation
Singlestation
Singlestation
Singlestation
Singlestation
2000 Professional SP2
x
x
2000 Professional SP3
x
x
x
x
2000 Professional SP4 (KB828741)
x
x
x
2000 Server SP2
x
x
x
x
2000 Server SP3
x
x
x
x
x
x
x
x
2000 Server SP4 (KB828741)
x
x
x
x
x
x
2000 Advanced Server SP2
x
x
x
x
2000 Advanced Server SP3
x
x
x
x
x
x
x
x
2000 Advanced Server SP4 (KB828741)
x
x
x
x
x
x
XP Professional
x
x
XP Professional SP1a
x
x
x
x
x
*13)
XP Professional SP2 (KB319740)
x
x
*8)
x
x
x
x
x
x
Server 2003
*8)
x
x
Server 2003 SP1
V6.0 SP1

*9)

WinCC/Audit

WinCC/Connectivity Pack

WinCC/DataMonitor

WinCC/Industrial
DataBridge
WinCC/IndustrialX

Trend Micro Server Protect V5.56


Trend Micro OfficeScan NT ab 5.02
Symantec AntiVirus Corporate Edition
V8.1
Symantec pcAnywhere V10.5
Symantec pcAnywhere V11.5
"RealVNC" Enterprise Edition V4.6 *17)
OPC Data Access
V2.05a
Spezification *16)
V3.00
OPCS Historical Data
V1.10
Access (HDA) *12)
OPC Alarms and
V1.10
Events (A&E) *12)
OPC XML Data Access
V1.00
*12)

x *7)

x
x

x
x

x *7)

x *15)
x *15)

x
x

x *15)
x *15)

x
x

x *15)
x *15)

x
x

x
x *15)
x *15)

*15)

*15)

*15)

x
x

*15)

x
x

*15)

*15)

x
x

*15)

x
x

x *15)
x *15)

x
x

*15)

x
x

*15)

x
x

*15)

*6)

x
x

(V6.0)
(V6.1)
(V6.1)
(V6.2)
(V6.2)
(V6.3)
(V6.3)

*18)

x
x *6)
x
x
x
x
x
x
x

WinCC Configuration Tool


WinCC Archive Configuration Tool
WinCC CrossReferenceAssistant
WinCC Communication Configurator
Variablen Export/Import
Variablensimulator
Dynamic Wizard Editor
Documentation Viewer
Easy Language

CD 07/2001 SP5 HF2


CD 11/2002
CD 11/2002 SP1
CD 11/2003
CD 11/2003 SP1
Edition 2005
Edition 2005 HF1

V5.2
V5.2 SP1
V5.3
V5.3 SP1
V5.3 SP2
V5.3 SP3
V5.4
V5.4 SP1
V5.4 SP2
V5.4 SP3

STEP 7 *10)

SIMATIC NET

SIMATIC WinCC V6.0

x
x

x
x

x
x
x
x

x
x
x
x

x
x
x
x
x

x
x
x *1)
*2, 5)

x
x *3, 5)
x *5)

V6.0
V6.0 SP1
V6.0 SP2

V6.0
V6.0 SP1
V6.1
V6.1 SP1

V6.0
V6.0 SP1
V6.1
V6.1 SP1

V6.0
V6.0 SP1
V6.1
V1.1

x
x
x

x
x
x
x
x
x
x
x
x

x
x

This entry was updated last time 24th of April 2013.


You will find the newest list for download at our Compatibility Tool.
http://support.automation.siemens.com/WW/view/en/64847782
Use the upper navigation after starting the Compatibility Tool and click at "Tools" for downloading the lists.

Changedate: 29.04.2013

This entry is from the Service&Support portal of Siemens AG,


Sector Industry, Industry Automation and Drive Technologies.
The general terms of use (http://www.siemens.com/terms_of_use) apply.

Page: 1/2

Entry-ID: 21927773

With what are SIMATIC WinCC V7.x, V 6.x and V5.x compatible?

WinCC Version
Software

V6.0
V6.0 SP4

WinCC/ODK

WinCC/ProAgent

*14)

V6.0
V6.0 SP1
V6.0 SP2
V6.0 SP3
V6.0 SP4

WinCC/Redundancy

V6.0
V6.0 SP1
V6.0 SP2
V6.0 SP3
V6.0 SP4

WinCC/Server

V6.0
V6.0 SP1
V6.0 SP2
V6.0 SP3
V6.0 SP4

WinCC/User Archives

V6.0
V6.0 SP1
V6.0 SP2
V6.0 SP3
V6.0 SP4

WinCC/Web Navigator

V6.0
V6.0 SP1
V6.1
V6.1 SP1

Simatic Logon

V1.1
V1.2
V1.2 SP1
V1.3
V1.4
V1.4 SP1
V1.4 SP2
V1.4 SP3

WinBDE

V7.2
V7.2 SP1
V7.2 SP2

SIMATIC WinCC V6.0


V6.0
V6.0 SP1
V6.0 SP2
V6.0 SP3
V6.0 SP4
Client /
Client /
Client /
Client /
Client /
Server
Server
Server
Server
Server
Singlestation
Singlestation
Singlestation
Singlestation
Singlestation
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
x
*4)
x
x
x
x
x
x
x
x

*1) The module CP1613 A2 may be used with WinCC6.0+SP2 and the delivered SIMATIC NET V6.2. In this case you should use the driver for S7-TCP/IP, which is delivered with the module
CP1613 A2.
*2) WinCC V6.0+SP3 was delivered with SIMATIC NET V6.2+SP1 until the end of may 2005.
*3) WinCC V6.0+SP3 is delivered with SIMATIC NET 2005 since june 2005.
*4) at WinCC V6.0 SP3 + HF1
*5) WinCC is delivered with SIMATIC NET Softnet-S7 Lean
*6)
It is not absolutely necessary to have WinCC installed. In this case you cannot read/write data from/to WinCC. But it is a requirement to install MS Excel 2000 / XP /2003.
*7) When you install pcAnywhere in English on Windows Server 2003 Standard Edition, warnings are displayed. According to Symantec releases, Symantec does not provide support for
pcAnywhere V10.5 operated on Windows Server 2003 Server Standard Edition.
*8) Standard und Enterprise Edition
*9) Notice operating system, entry 9859007
*10) Notice operating system, entry 8250891
*11) All WinCC Clients of a project must be installed with the same version of the operating system (inclusive SP).
Remark: Dont use an older Windows Server version on the WinCC Client as at the WinCC Server
*12) OPC HDA, OPC A&E and OPC XML DA is not possible in WinCC Demo mode. You need a WinCC ConnectivityPack license.
*13) Only released for WinCC Clients
*14) Only released for WinCC Singlestation.
*15) Installation of WinCC OPC Server is only released on WinCC client with own project.
*16) OPC DA is possible in WinCC Demo mode
*17) Find more informations concerning "RealVNC" for WinCC in entry-ID 55422236.
*18) Installation of WinCC V6.0 SP3a HF32 is necessary for using "RealVNC" Enterprise Edition V4.6.

Changedate: 29.04.2013

This entry is from the Service&Support portal of Siemens AG,


Sector Industry, Industry Automation and Drive Technologies.
The general terms of use (http://www.siemens.com/terms_of_use) apply.

Page: 2/2