Beruflich Dokumente
Kultur Dokumente
Product Features
Maintain high performance
Reliable operation between -20 C to 45 C ambient
temperature
Rated average life of 40,000 hours (tested to B50 L70
requirement)
50,000 switching cycles
O
Easy to experience
CRI 80
Instant on, no flicker or buzz
Advanced optical design ensures a uniform light output
and superior optical efficiency
Environmental Friendly
No mercury and glass
No breakage and pollution risk
Energy Efficient
Energy savings of up to 60%*
Compatibility
Compatible with electromagnetic ballasts by replace the
fluorescent starter with Philips starter, eliminating the
need for rewiring and allows fixture to maintain original
CE compliance
Application
Retail
Industry
Offices
Hospitals
Parking Lots
Schools
Warehouses
Public Areas
BEFORE
AFTER
Photometric Diagrams
The Photometric diagram depicting the top down mounted lighting fixtures in a specific area and a numerical grid of the
maintained lighting levels that the fixture will produce in that specific area. Pictures below show the photometric diagrams of a
typical Philips Master LEDtube's application.
1 x TLED 16W 4000K /6500K
1 x 1600 lm
100%
95%
90%
85%
80%
75%
70%
5000
10000
35000 40000
Hours
Temperature
Master LEDtube's excellent thermal design ensures low temperature during operating, which brings reliable and stable
product performance throughout life time.
Operating temperature
T operating
min -20C
max +45C
Storage temperature
T storage
min -40C
max +65C
T case
+45C
100%
99%
Lumen (% )
98%
T c Max: 45 oC
97%
96%
95%
Tc.
94%
93%
92%
45
50
55
60
23mm
65
Tc ( C)
19m
AC INPUT SIDE
Philips logo side
Tc.
19mm
Technical specification
10NC
Product Description
Wattage
Equivalent
Voltage
Cap
Length
Fluorescent
Beam
Lifetime
angle
Wattage
(W)
(W)
(V)
9290002847
16
36
100-240
G13
1200
9290002848
16
36
100-240
G13
1200
Lumen
Lumen
Color
output
output
Temp
CRI
(Typical)
(Maximal)
(hrs)
(lm)
(lm)
(K)
(Typical*)
150
40000
1600
1760
4000
83
150
40000
1600
1760
6500
83
(mm)
*Minimum CRI is 80
D2
Accessories
EMP
C1
D1
MASTER LEDtube
Protector EMP
Product
A1
A2
A3
C1
D1
1200mm
1198
1205
EMP
1212
25.68
34.5
D2
28
21.5
A3
A2
A1
D1
D2
Dimensions (mm)
Installation Warning
Application Notes
Installation Guide
EM ballast based system
For EM ballast installations please check if a Power Factor Correcting
Capacitor is installed in the existing circuit. If yes, please follow the
instructions below:
Please simply remove the capacitor if it is in parallel with the EM Ballast
Please short circuit the capacitor if it is in series with the EM Ballast
In case of 2ft/600mm lamps, if there is only one starter in the luminaire
for 2 lamps, or 2 starters for 4 lamps, then rewire according to the SAFE
rewiring instructions in next section
OFF
ON
Mains Off
OFF
ON
Turn on mains
OFF
ON
Mains Off
Diagram A
Diagram B
OFF
L
N
LEDtube
L
N
Warning sticker
LEDtube
ON
LEDtube
Turn on mains
1
2
3
4
C
D
C+D
D+D
Diagram C
LEDtube
LEDtube
Diagram D
LEDtube
OEM Guideline
Lifetime and Lumen Maintenance
100%
100%
90%
80%
70%
60%
50%
40%
30%
20%
10%
0
Lumen Maintenance
95%
90%
85%
80%
75%
70%
10000
20000
30000
40000
50000
60000
Hours
80%
TC=65
70%
TC=55
60%
TC=45
50%
40%
30%
20%
B50L70
50000
40000
30000
20000
10000
10%
0
B10L70
60000
10000
20000
30000
Hours
40000
50000
60000
0
35
45
55
o
TC ( C)
65
75