No.02-2-G-09-023-L-Rev.3
Date: Dec. 2007
6NY16L,S165L,NHL,6N165L,S185(A)(D)L,
Use
Marine Aux. & Industrial
6N18(A)L,6/8N21(A)L,M200(A)L,M220(A)L,M200HLEN
Eng.Model
12G(A) L, T240 (A) L (-ST, ET, GT), 6EY18L, 6EY26L
, T260L (-ST, ET, GT, SX, EX, GN)
Engine Nos.
12T26L,(8)Z280L,6/8Z,12/16ZL,6/8N280L,6/8N330L
In order to ensure satisfactory starting and reduce black smoke emissions, the fuel injection amount on engine starting
is set at the values when the engines are shipped from our plant.
This fuel injection limit may be varied due to servicing, etc. and starting performance may drop and black smoke
emissions may increase due to secular degeneration of the plunger barrel. At such times, adjust the injection amount
to the limit rack values in Table 1 below and operate the engine for checking.
Table 1
Model
Model
6NY16L
S165L
NHL (1500rpm)
NHL (1800rpm
5.51
5.51
M220L
M220AL
12GL
12GAL
191
181
171
201
T240 (A) L
19.51
6N165L
S185DL
S185AL
S185L
6N18L
6N18AL
M200L
M200AL
M200HLEN
6/8N21L
12.51
161
141
250.5
250.5
231
211
181
250.5
T260L-ST, ET, GT
12T26L
T260L-SX, EX
6N260L(excluding GN)
6N260L-GN
(8)Z280L
6/8ZL
12,16ZL
6/8N280L
6/8N330L
211
211
15.51
20.51
231
181
181
231
211
38 44
6/8N21AL
250.5
6EY26L
191
6EY18L
250.5
Notes
Use the indicator scales for the NHL and 6N165L. If 25% load operation is not possible in the NHL, apply the
intermediate value between the 0% and 50% load as the scale value at 25% load.
Since the NHL engines in Hokkaido are operated on the special light oil, No.3, the injection termination position
moves towards the fuel increasing direction. In this particular case, add 2 to the value in the table above for
the fuel limit value.
If the engine is operated at load with the loop piping with the FO return pipe connected to the feed pump inlet,
the FO injection pump temperature may exceed the flash point of the fuel oil. In this case, vapor is produced
inside the plunger after stopping the engine and the engine may not be re-started with the FO rack position above.
If you loosened the rack limit for heated engine starting once, be sure to return the value to the limit position above
after completing the trial operation.
Approved
LARGE POWER PRODUCTS OPERATIONS DIV.
QUALITY ASSURANCE DEPT.
FAX.No.: +81-6-6488-4003
Checked
Drawing
2/2
Stop piston
Safety system stop piston
FO limit piston
Lock nut
Cap nut
Clialance.A
Adjust screw