Sie sind auf Seite 1von 12

SUSPENDED CEILIN G SYS TEMS

MONTREAL TORONTO CALGARY EDMONTON VANCOUVER

THE STRENGTH WITHIN

SUSPENDED CEILING SYSTEMS


Bailey offers a wide range of easy to install, low maintenance
and attractive suspended ceiling systems for all applications.

Bailey Metal Products Limited offers a complete range


of Suspended Ceiling Systems and Accessories for all your
building needs. With ofces across the country, Bailey is the
leading manufacturer and supplier of a complete range of
wall and ceiling systems.

www.bmp-group.com

The comprehensive design of the Bailey Suspended Ceiling


Systems will accommodate all your ceiling installation requirements. These systems, manufactured in aluminum or steel,
meet all ULC re rating requirements. They are versatile and
easy to install.
Bailey Suspended Ceiling Systems incorporate features
such as superior strength, design exibility, environmental
protection and multiple colour and prole choices for appealing
aesthetics. With easy installation and the wide variety of
products, sizes and accessories, Bailey is your best choice for
suspended ceilings.
Bailey Metal Products Limited has a reputation for
exceptional customer service and is proud to offer quality
building products through our plants across Canada for over
50 years. Should you have any questions about our ceiling
systems, or any other Bailey products please contact the ofce
near you. Thank you.

2
TABLE OF CONTENTS
EXPOSED SYSTEMS

Lance-Lock System 1800


15/16 Exposed Tee System - Fire-Rated

Page 3

Lance-Lock System 900


15/16 Exposed Tee System - Non-Rated

Page 4

Shadowline System 800


9/16 Exposed Tee System - Non-Rated

Page 5

Lance-Lock System 400


All Aluminum Exposed Tee System

Page 6

ENVIRONMENTAL SYSTEMS
Lance-Lock 1400 15/16 Rated System

Page 7

Page 7

Page 7

Lance-Lock 700 15/16 Class A System


Lance-Lock 600 916 Class A System

Accessories and Conversion Chart

Page 8

Lance-Lock Punching Details


and Relocatable System

Page 9

Colours and Finishes

Page 10

Bailey System Layouts

Page 11

Specications and Installation Requirements

Page 12

L ANCE-LOCK SYSTEMS
15/16 EXPOSED TEE SYSTEM FIRE-RATED

Bailey Lance-Lock System 1800 exposed tee re-rated system


has been fully re tested at Underwriters Laboratories of Canada
(ULC), UL in the U.S.A., and Warrington Fire Research Centre
in the United Kingdom. The re-rated main tee incorporates the
Bailey Patented Expansion Joint. Under re conditions, this in-line
expansion joint expands linearly reducing the rotation effect on
the grid itself.

U.L.C. Classied for re resistance designs

Baileys ULC re-rating listings cover all building applications through


their 1 and 2 hour oor/ceiling and 1 hour roof/ceiling designs.

Rapid assembly for economical installation

All re-rated cross tees are of 1 1/2 high structural design with
re-rated end joinery designed to expand through the main tee
slot under re conditions.

www.bmp-group.com

BAILEY L ANCE-LOCK SYSTEM 1800

ADVANTAGES

Straight push-in joinery with stepped edge


for a crisp, clean main tee/cross tee intersection
ASTM C635 Intermediate Duty Rating

Engineered for maximum design exibility


with economy and durability

In addition to meeting re rating requirements, Bailey Lance-Lock


System 1800 delivers all installation, economy and durability
featured in the non-rated System 900.

1 1/2

15/16

1 1/2

15/16
15/16

L ANCE-LOCK SYSTEMS

www.bmp-group.com

BAILEY L ANCE-LOCK SYSTEM 900

15/16 EXPOSED TEE SYSTEM NON-RATED

Bailey Lance-Lock System 900 exposed tee non-rated system


is a fully engineered, double web design. The main runners are
1 1/2 (38mm) high, available from stock in 10 (3000mm) and
12 (3600mm) lengths. Custom lengths up to 12 can easily be
manufactured and all main runners are available with either
conventional or basketweave end joinery.
The 1 standard and 1 1/2 structural cross tees have a straight
push-in locking design facilitating ease of installation and
removal. All cross tees are designed with a toboggan or
stepped end ensuring a crisp, clean appearance.

ADVANTAGES
Engineered and tested to ASTM C635
Intermediate and Heavy Duty Standards
Designed for installation in either conventional
or basketweave layouts
Straight push-in joinery with stepped edge
for a crisp, clean main tee/cross tee intersection
Sturdy double web design
Rapid assembly or disassembly for ease
of installation or removal for relocation
Engineered for maximum design
exibility with economy and durability

1 1/2

1
15/16

15/16
15/16

SHADOWLINE SYSTEMS
9/16 EXPOSED TEE SYSTEM NON-RATED

Shadowline System 800 9/16 narrow face exposed grid


system enhances the look of the ceiling by decreasing the
visibility of the suspension systems.
The Bailey Shadowline Suspended Ceiling System is a Class A
non-rated system. This system combines the engineered strength
of the Bailey Lance-Lock system, with the sleek look provided by
narrower exposed face.
In addition, Shadowline System 800 incorporates the Bailey
panel centering device, ensuring panels are always centered.
this feature adds rigidity to both main and cross tees.
Main tees are available in 10 and 12 lengths to meet any
layout demands. Custom lengths up to 144 are available by
special order.

www.bmp-group.com

SHADOWLINE SYSTEM 800

ADVANTAGES
All products use a 1 1/2 body for added strength
Double web design body

Straight push-in joinery with stepped edge for a


crisp, clean main tea/cross tee intersection
Engineered with the Bailey panel centering device
for rigidity and precise panel location
Rapid economical installation
Hanger holes in grid bulb and body for complete
installation exibility
Finished in Tile White, an ideal match for today's
ceiling panels.

1 1/2

9/16

1 1/2

9/16
9/16

L ANCE-LOCK SYSTEMS
15/16 ALL ALUMINUM EXPOSED TEE SYSTEM

www.bmp-group.com

BAILEY L ANCE-LOCK SYSTEM 400

Bailey Lance-Lock System 400 15/16 Exposed Grid system is


manufactured from 100% aluminum, providing maximum
protection in higher humidity environments.

Available in white or natural aluminum nish, Bailey Lance-Lock


System 400 offers the versatility of conventional design. This all
aluminum system meets the requirements of areas such as kitchens,
food processing operations, etc.
Main tees are available in 10 and 12 lengths to meet any layout
demands.
Cross tees are available in standard lengths of 1, 2, 4, and 5.

ADVANTAGES
All products use a 1 1/2 body for added strength
Double web design body
Straight push-in joinery with stepped edge for
a crisp, clean main tee/cross tee intersection
White or natural aluminum nish design
Rapid economical installation
Hanger holes in grid bulb and body for complete
installation exibility
Designed to provide maximum corrosion resistance

1 1/2

1 1/2
15/16

15/16
15/16

L A N C E - LO C K E N V I RO N M E N TA L SYS T E M S
BAILEY L ANCE-LOCK SYSTEM 1400
Lance-Lock 1400 system not only suits
the design needs of hostile environments,
but is also classied for ULC Fire Resistance
Designs.
As with Lance-Lock 700, hot dipped
galvanized steel provides the environmental
protection you need, while meeting your
ULC re rating requirements at the same
time.

15/16 FIRE-RATED SYSTEM

ADVANTAGES
Provides a ULC Fire Rated
Environmental System
Heavy and Intermediate
ASTM C635 classication
Double web, hot dipped
galvanized components
Lance-Lock straight lock-in
end joinery

1 1/2

15/16

1 1/2

BAILEY L ANCE-LOCK SYSTEM 700


Lance-Lock 700 is designed for installation
in hostile environments, where the ceiling
will be subjected to high humidity.
Lance-Lock 700 is manufactured from
hot dipped galvanized steel to provide
maximum protection in areas such as food
process plants, kitchens and health care
centers where regular washing of the
ceiling may be required.
At the same time, Lance-Lock 700
incorporates the features and benets
of the Lance-Lock 900 system, including
superior strength, ease of installation
and design exibility.

Manufactured from hot dipped galvanized


steel, Lance-Lock 600 provides environmental protection with the aesthetics of
narrow grid in one system.

15/16 CLASS A SYSTEM

ADVANTAGES
Hot dipped galvanized steel
For Installation in high
humidity environments
Double web design body
Heavy and intermediate Duty
ASTAM C635 classications

1 1/2

Available in all standard


colours

15/16

15/16

BAILEY L ANCE-LOCK SYSTEM 600


Lance-Lock 600 offers the same design
features and benets as the 700 system,
in a 9/16 prole.

www.bmp-group.com

15/16

9/16 CLASS A SYSTEM

ADVANTAGES
1 1/2 double web design
Narrow grid design
Hot dipped galvanized steel
Designed for protection in
hostile environments
1 1/2

9/16

1 1/2

9/16

L ANCE-LOCK SUSPENDED CEILING ACCESSORIES


BAILEY WALL ANGLES
Bailey provides a wide variety
of mouldings produced in
steel, offering various colours
and nishes to meet most
design needs.

Angle Mould

BMX32 Flex Wall Mould

BMF F Mould

BMX32 Flex Wall Mould

3/4
Dimension
Variable

1/2
3/4

1/2 or 5/8 Board

BAILEY COLUMN RINGS


Available in steel or aluminum with baked enamel
paint nish to match the grid. Custom made to specic
dimensions. Post painted to match any design.

Reveal

Conventional

www.bmp-group.com

CORNER CAPS

Available for both square


or round (bullnose) corners.

BA 36

BA 35

BA 37 Bullnose
1

3/4

3/4

MISCELL ANEOUS
BA 53 installation Clamp
A multipurpose clamp, often used to hold
your line to the wall angle when laying
out and levelling your ceiling.

BA 21 Hold Down Clip


For use with 1 1/2 ceiling grid over
5/8, 1/2, 3/4 panels to resist
upward wind loading on tiles.
Paired Tee Clip
Provides a simple method of introducing
a double main tee into your ceiling system.

PAIRED TEE
CLIP

The space between the double main tees


allows for air return or air handling
through linear diffusers.
Opening

Main Runner

Product Number

Center to Center
Dimension

Opening
Dimension

B134

1 3/4

3/4

B200
B214

2
2 1/4

1
1 1/4

B212
B300

2 1/2
3

1 1/2
2

BAILEY ARCHITECTURAL FL AT STRAP


Bailey flat strap is available in various
widths and finishes to match your ceiling
or custom colour requirements.

Architectural at straps are ideal for curved


and illuminated kitchen type ceilings.
-10 lengths.

AFS-10

METRIC MODULE CONVERSION CHART (All dimensions indicate nominal size)


Panel/Tile Width/Length

Panel/Tile Thickness

Grid Width/Length

12 x 12 = 300mm x 300mm
12 x 24 = 300mm x 600mm
24 x 24 = 600mm x 600mm
24 x 48 = 600mm x 1200mm
24 x 60 = 600mm x 1500mm
20 x 60 = 500mm x 1500mm
30 x 60 = 750mm x 1500mm

1/2 = 13mm

9/16 =
15/16 =
1
=
2
=
4
=
5
=
8
=

5/8 = 16mm
3/4 = 19mm
1

= 25mm

14mm
24mm
300mm
600mm
1200mm
1500mm
2400mm

Imperial/Metric Conversion
10 = 3000mm
12 = 3600mm

.012
=
.015
=
.018
=
.020
=
.033
=
10.76 sq.ft. =
2.205 lbs =
3.94
=

.31mm
.38mm
.46mm
.51mm
.84mm
1 sq. metre
1kg
100mm

L A N C E - LO C K SYS T E M D E TA I L S
BAILEY L ANCE-LOCK

IMPERIAL/METRIC PUNCHING DETAILS

CROSS TEES Web Height 1 1/2 (38mm)

20

20

20

20

20

20

75mm

150mm

150mm

75mm

500mm

500mm

500mm

500mm

500mm

500mm

Be/Bef 144 24 Slots @ 6 o.c. Be/Bef 3600 24 Slots @ 150mm o.c

10

10

125mm

250mm

250mm

125mm

Be 120 12 Slots @ 10 o.c. Be 3000 12 Slots @ 250mm o.c

Bef 120 5 Slots @ 20 o.c. Bef 3000 5 Slots @ 500mm o.c.

14

10

10

14

150mm

350mm

250mm

250mm

350mm

150mm

Bef 60 5 Slots as shown Bef 1500 5 Slots as shown

CROSS TEES Web Height 1 (25mm)

12

12

12

12

300mm

300mm

300mm

300mm

12

12

12

12

300mm

300mm

300mm

300mm

Bef 48 3 Slots as shown Bef 1200 3 Slots as shown

Be 48 3 Slots as shown Be 1200 3 Slots as shown

12

12

12

12

300mm

300mm

300mm

300mm

Be 24 1 Slot @ mid-point Be 600 1 Slot @ mid-point

Bef 24 1 Slot @ mid-point Bef 600 1 Slot @ mid-point

NOTE: Stocked cross tees less than 48 (1200mm) long are produced without holes. Custom punching to suit any layout is easily accommodated.
Lance-Lock System 900 = Be Non-Rated Assemblies
Lance-Lock System 1800 = Bef Fire-Rated Assemblies

BAILEY RELOCATABLE CLIP/REMOVABLE CROSS TEE SYSTEM


Standard BSC-3 Clip Installation

The Bailey Relocatable Clip is designed to allow a cross tee


to main tee connection within non-compatible systems and nonmodular layouts.

Main Runners

Existing ceilings may be changed or added to using Bailey grid,


irrespective of the original ceiling system. In ceilings requiring
the installation of custom size xtures, diffusers, speakers, etc.,
additional cross tees can easily be locked in place, even after
ceiling completion.
BSC-3

1 1/2 Cross Tee

BSC-3 Clip

Location and Locking Lances Removed


Locating Lance

www.bmp-group.com

MAIN RUNNERS Web Height 1 1/2 (38mm)

COLOUR AND FINISHES


THE BAILEY COLOUR GUIDE

THE BAILEY COLOUR GUIDE


The Baileys Lance-Lock System introduces a collection of colours
designed to compliment current interiors and those of the future.
From standard white to metallic nishes, Bailey offers a full
colour spectrum.

www.bmp-group.com

Baileys Lance-Lock series are available in these standard colours.


Ask your dealer or sales representative for information on any
custom colours you may require.

10

STANDARD

White

Black

Platinum

Parchment

Haze

Manilla

Sandstone

Taupe

METALLICS

Chrome

Brass

Aluminum

*For special colours, please consult your sales representative


NOTE: The colours shown have been reproduced with all the delity possible with commercial printing processes. A specic colour may appear different from one class of
product to another. For assurance, ask for an actual sample to see the true colour of the product you select.

B A I L E Y SYS T E M L AYO U T S
CONVENTIONAL LAYOUT.

BASKETWEAVE LAYOUT
(System utilizing 120 cross tees as main memberS)

5 x 5 or 1500mm x 1500mm Module


20 X 60 or 500mm x 1500mm Sub-Module

5 x 5 or 1500mm x 1500mm Module


20 X 60 or 500mm x 1500mm Sub-Module
3 @ 20
= 5 - 0

Fixture Location
Where Crossed
375 500 500

15 20 20

Splice Location
Typical

Any Fixture
May Be
Absent or
Rotated 90
Without
Requiring
Additional
Hangers

Fixture Location
Where Crossed

3 @ 500
= 1500

NOTES:
MT = 1 1/2 Main Tee 10 Foot (3 metre)
CT = 1 1/2 Cross Tee 60 Inch (1500mm)

Any Fixture
May Be Absent

CONVENTIONAL LAYOUT.

Fixture Location
Where Crossed

Any Fixture
May Be Absent

CONVENTIONAL LAYOUT.

4 x 4 or 1200mm x 1200mm Module


2 x 4 or 600mm x 1200mm Sub-Module

Fixtures @ 8 - 0 O.C.
3

24

4 x 4 or 1200mm x 1200mm Module


2 x 2 or 600mm x 600mm Sub-Module

11

Fixture Location
Where Crossed

24

24

24

75

600

600

1200

600

Fixtures @ 6 - 0 O.C.

600

24

24

4 - 0

Splice Location
Typical

NOTES:
CT 1 = 1 1/2 Cross Tee 120 Inch (3000mm)
CT 2 = 1 1/2 Cross Tee 60 Inch (1500mm)

Hanger Location
Typical
75

600

600

NOTES:
MT = 1 1/2 Main Tee 12 Foot (3600mm)
CT = 1 or 1 1/2 Cross Tee 48 Inch (1200mm)

Hanger Location
Typical

Any Fixture
May Be Absent

NOTES
MT = 1 1/2 Main Tee 12 Foot (3600mm)
CT1 = 1 or 1 1/2 Cross Tee 48 Inch (1200mm)
CT2 = 1 or 1 1/2 Cross Tee 24 Inch (600mm)

www.bmp-group.com

Splice Location
Typical

Hanger
Location
Typical

1500

1500

5 - 0

5 - 0

125

Splice Location
Typical

Any Fixture
May Be Absent

NOTE: For xture loads with specied material thickness, hanger spacing and selected cross tee height, please contact Bailey Metal Products Limited for allowable loads
for your specic application.

CO D E S A N D S TA N DA R D S ( A r c h i t e c t u r a l S p e c i f i c a t i o n s )
United Kingdom
All re testing was completed at the
Warrington Fire Research Center. The
Bailey Lance-Lock System is re-rated for
1 hour as required under British Standard
476 Part 23 1987.

CODES AND STANDARDS


The Bailey exposed grid suspended
ceiling systems are manufactured
to the following standards:
ASTM C635

Metric Installations:
All components are manufactured in
both Metric and Imperial as referenced.

Grade of Steel:
ASTM A 366/A 366M or better
Steel Coating: ASTM C635 or better

ARCHITECTURAL SPECIFICATIONS

12

Canada
Lance-Lock is re-rated for the requirements
of both 1 and 2 hour roof/ceiling and
oor/ceiling designs. All testing was carried
out at Underwriters Laboratories of Canada
(ULC) in accordance with CAN 4 S101M
Guide Item 40U 18.18.
ULC Time Rated Designs
C 204, D 203, D 205, G 208, G 218, I 210,
I 211, I 214, I 215, L 201, R 222, R 224.
United States
Bailey is UL Classied for the requirements
of both 1 and 2 hour roof/ceiling and
oor/ceiling re rated designs. All testing
was conducted in accordance with
ANSI/UL 263 (ASTM E 119 AND NFPA 251).
Please contact our ofce for specic
design numbers.

1. General:
The 15/16, 9/16 exposed grid
suspension systems are manufactured
by Bailey Metal Products Limited.

3.1 The Bailey Exposed Grid Suspension


System shall be installed in accordance
with the requirements of ASTM C636.
Deection of any component shall not
exceed 1/360 of the span.
3.2 Main Runners to be installed 24, 36
48, or 60 on centre or as specied on
drawings, and directly suspended by wire
not less than 12 gauge in thickness.
Suspension wire to be spaced at 48 or
60 on centre as required.
3.3 Cross Tees to be interconnected to
main runners at 20, 24, 36, 48, or 60
on centre, or as required.

2. Materials:
2.1 Lance-Lock System.
The 15/16 (Fire-Rated), double-web
design, Lance-Lock Exposed Grid System,
shall conform to the requirements of the
Intermediate Duty and Heavy Duty
classication of ASTM C635.
2.2 Shadowline System.
9/16 Shadowline Exposed Grid System
of double-web design, incorporates the
Bailey tile-centering device.
2.3 All materials are cold rolled steel
with protective coating to ASTM C635,
or better. Pre-painted baked-on capping
Global White Tile.

Characteristics, properties or performance of materials or


systems manufactured by Bailey Metal Products Limited
herein described are derived from data obtained under
controlled test conditions. Bailey makes no warranties,
express or implied, as to their characteristics, properties or
performance under any variations from such conditions in
actual construction. Bailey Metal Products Limited assumes
no responsibility for the effects of structural movement.

3.4 Wall mouldings (BM5 Angle), (BMR10


Reveal Mould) to be installed wherever
ceiling meets vertical surfaces.
3.5 Install supplemental hangers where
the weight of light xtures or other ceiling
apparatus, cause the deection of the
ceiling grid to exceed 1/360, as specied
in ASTM C636.

NOTE: All hanger wire to be tightly


wrapped with a minimum of three
full turns.

See Bailey Acoustical Ceiling Systems literature


for product details, recommended uses and
application instructions.

NOTICE: The Information in this document is subject to


change without notice. Bailey assumes no responsibility
for any errors that may appear in this document.

BAILEY METAL PRODUCTS LIMITED


MONTREAL
LES PRODUITS METALLIQUES BAILEY LTEE

525 Avenue Edward VII


Dorval QC H9P 1E7
Tel: (514) 735 3455
(800) 263 3455
Fax: (514) 735 5052

TORONTO
One Caldari Road
Concord ON L4K 3Z9
Tel: (905) 738 9267
(800) 668 2154
Fax: (905) 738 5712

CALGARY
3924 27th Street NE
Calgary AB T1Y 5K7
Tel: (403) 248 3536
(800) 665 2013
Fax: (403) 248 0288

EDMONTON
5710 Roper Road N.W., Suite 101
Edmonton AB T6B 3G7
Tel: (780) 462 5757
(800) 563 1751
Fax: (780) 465 3791

sales@bmp-group.com www.bmp-group.com

VANCOUVER
7715 Anvil Way
Surrey BC V3W 6A2
Tel: (604) 590 5100
(800) 818 2666
Fax: (604) 599 5371

4874-0709-2500

www.bmp-group.com

LANCE-LOCK FIRE RESISTANCE RATINGS

3. Installation:

Das könnte Ihnen auch gefallen