Sie sind auf Seite 1von 5

DET NORSKE VERITAS

TYPE APPROVAL CERTIFICATE


CERTIFICATE NO. D-3284
This Certificate consists of 4 pages and replaces D-2632
This is to certify that the

Pipe Fittings
with type designation(s)

LONGSWEEP SWIVEL JOINTS AND SERVICE LOOPS


Manufactured by

FMC Technologies, Inc.


Stephenville, Texas - United States
is found to comply with:
- Det Norske Veritas Offshore Standard DNV-OS-E101, Drilling Plant, October 2006
and Det Norske Veritas understanding of the implementation and interpretation of:
- PSAs Regulations Relating to the Design and Outfitting of Facilities etc. in the Petroleum Activities (the
Facilities Regulations), Chapter IV, last amended 20 December 2007.

Application
See design limitations on page 2
Place and date
Houston, 2008-05-12
for DET NORSKE VERITAS (USA), INC.

Richard Helmersson
Principal Engineer

This Certificate is valid until


2012-05-31

Brandon Caraway
Senior Engineer

Local Office
DNV Houston

Notice: This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid.
The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed.
If any person suffers loss or damage which is proved to have been caused by any negligent act or omission of Det Norske Veritas, then Det Norske Veritas shall pay compensation to such person for his proved direct loss or damage. However, the
compensation shall not exceed an amount equal to ten times the fee charged for the service in question, provided that the maximum compensation shall never exceed USD 2 million.In this provision Det Norske Veritas shall mean the Foundation
Det Norske Veritas as well as all its subsidiaries, directors, officers, employees, agents and any other acting on behalf of Det Norske Veritas.

DET NORSKE VERITAS AS


Form No.: 20.90a

Issue: January 98

VERITASVEIEN 1, 1322 HVIK, NORWAY

TEL: (+47) 67 57 99 00

FAX: (+47) 67 57 99 11

Page 1 of 5

Cert. No.:
File No.:
DNV Project no.:
Case No.

D-3284
523.83
47000848
262.1-005077-2

Product description
-

2 LS 15 Chiksan Longsweep Swivel Joints with Figure 1502 Weco Wing Union
End Connections.
2 LS 15 Chiksan Longsweep Standard Wall Service Loop Assemblies with
Integral Figure 1502 Weco Union Ends.
2 LS 15 Chiksan Longsweep Light Weight Service Loop Assemblies with
Integral Figure 1502 Weco Union Ends.
1.5 LS 15 Chiksan Longsweep Swivel Joint with Figure 1502 Weco Wing Union
Connections.
1 LS 15 Chiksan Longsweep Swivel Joint with Figure 1502 Weco Union Connections.

Application/Limitation
Minimum Design Temperature

: -29C (-20F)

Maximum Working Pressure


- 1, 1.5, & 2 LS 15 Swivel Joint & Service Loops

: 15,000 psi @ 225F


10,000 psi @ +20 F to 350F

Service

: Standard (water, mud, cement, nitrogen,


frac fluids and inhibited acid)

Type Approval documentation

DET NORSKE VERITAS AS


Form No.: 20.90a

Issue: January 98

VERITASVEIEN 1, 1322 HVIK, NORWAY

TEL: (+47) 67 57 99 00

FAX: (+47) 67 57 99 11

Page 2 of 4

Cert. No.:
File No.:
DNV Project no.:
Case No.

D-3284
523.83
47000848
262.1-005077-2

Fabrication Procedures
Test Procedures:
TL-1

Rev.T

Q00040 (alt.) Rev. I

NDE Procedures:
NE-03

Hydrostatic testing and lubrication of Chiksan Swivel


Joints and Piping Assemblies
Standard production testing requirements for swivel joints,
pup joints and C&C hoses

Rev. E

Specification for Wet Magnetic Particle Examination of


finish Machined Parts using Sampling Plan (1.0 AQL) API 6A/16C & MSS SP-53 Acceptance Criteria

Q00185 (alt) Rev. C

Specification for Wet Magnetic Particle Examination of


finish Machined Parts using Sampling Plan (1.0 AQL) API 6A/16C Acceptance Criteria

Quality Procedures:
AS-80

Rev. H

Stamping and Locating Guidelines for Banding used on of


Flowline Assemblies

Q00286 (alt) Rev. E

Stamping and Locating Guidelines for Banding and Labeling


used on of Flowline Assemblies

3257180

Rev. L

Specification for Serialization of Various Fluid Control


Products

Q00250 (alt) Rev. G

Specification for Serialization of Various Fluid Control


Products

3255981

Rev. J

Engineering Specification for Union Component


Identification

Q50012 (alt) Rev. C

Engineering Specification for Union Component


Identification

3258274

Stamping Information for Longsweep Components

DET NORSKE VERITAS AS


Form No.: 20.90a

Issue: January 98

Rev. D

VERITASVEIEN 1, 1322 HVIK, NORWAY

TEL: (+47) 67 57 99 00

FAX: (+47) 67 57 99 11

Page 3 of 4

Cert. No.:
File No.:
DNV Project no.:
Case No.
Q50043 (alt) Rev. B
Marking of product

D-3284
523.83
47000848
262.1-005077-2

Stamping Information for Longsweep Components

For traceability to this Type Approval Certificate the products are as a minimum to be marked
as follows:
"NV"
Type Designation and size
Manufacturer's name and trademark
Additional marking at manufacturer's option
Certificate retention survey
The arrangement is to be in accordance with Certification Notes No. 1.2, dated December 1996,
paragraph 4.3.

Documentation to be accompanied with each product/delivery


1.
2.
3.
4.
5.
6.
7.
8.
9.

Data book index


Equipment name, number, purchaser, etc.
Manufacturers statement of compliance
Assembly drawing
Actual material certificates as purchased and Charpy impact test records as applicable
Heat treatment records/charts when applicable
Pressure test reports
DNV Product Certificate
DNV Type Approval Certificate

Other conditions/comments

If the Minimum Design Temperature is less than 0 deg. C, Charpy Impact testing to be
conducted at or below design temperature with acceptance criteria of 20 ft-lbs. avg./13.3 ftlbs. minimum.
All NDE operators are to be qualified to Level II or better per SNT-TC-1A.
The client may specify inspection and/or documentation requirements in addition to the
approval conditions of this certificate in specific well control applications. In such cases,
those requirements are to be satisfied by the documentation which would accompany the
product or delivery.

END OF CERTIFICATE

DET NORSKE VERITAS AS


Form No.: 20.90a

Issue: January 98

VERITASVEIEN 1, 1322 HVIK, NORWAY

TEL: (+47) 67 57 99 00

FAX: (+47) 67 57 99 11

Page 4 of 4

Verification Form Sheet to be filed in Project File


Equipment:
Project ID:

SWIVEL JOINTS AND SERVICE LOOPS

Responsible Engineer:
Project Responsible:

Brandon Caraway
Check List

1 Call customer and verify the applicable rules, regulations, codes and
standards, end user, service requirements, rig, etc.
2 Verify rig requirements.
3 Perform an initial review of the submitted documentation to determine
if additional documentation is required. If additional documentation is
required, inform the customer immediately. If significant progress can
be made without the additional documentation, proceed with the
review; otherwise proceed to working on another project.
4 Verify customers calculations and perform additional calculations as
necessary. (Check dimensions, stresses, allowable, safety factors,
etc.)
4a If review of Finite Element Analysis is involved, perform these
additional steps:
Verify type of analysis, computer program used, assumptions, etc.
Verify the units, geometry, member size, section properties, material
properties, boundary conditions, etc.
Verify the applicability of the analysis loads and load steps versus the
real life possibilities including worst cases.
Verify deflections (good check), stresses, and the stress allowable per
code.
5 Verify material requirements to meet the required codes.
6 Verify NDE requirements to meet the required codes.
7 Verify welding requirements to meet the required codes.
8 Verify testing requirements to meet the required codes.
9 Verify Quality Plan to meet the required codes.
10 Verify the applicable rules, regulations, codes, and standards.
11 Verify DNV file number, page numbering, equipment description, etc.
12 Verify assumptions
13 Verify conditions
14 Verify design limitations.
15 Verify the comments section and their applicability.
16 Verify the correct DVR distribution.

Sign. Resp. Engineer: ________________________ Date: ____________

Sign. Verifier:

_______________________ Date: ___________

Resp. Engineer
(tick one)
Verified
N/A

Verifier
Verified

Das könnte Ihnen auch gefallen