05-Chapter 5 Data Configuration

Page 1 of 12

Table of Contents
Chapter 5 Data Configuration
5.1 About This Manual
5.2 Introduction
5.3 Displaying the Data Configuration Window
5.4 Configuring the Board Data
5.4.1 Configuring the Clock Board in the Slot 0
5.4.2 Configuring the Clock Board in the Slot 12
5.4.3 Configuring the LCIM Board
5.4.4 Configuring TSOU Board
5.4.5 Configuring the CCOU Board
5.4.6 Configuring TDRV Board
5.5 Configuring the Reference Source
5.5.1 Adding a Reference Source
5.5.2 Configuring Digital Signal Reference Source
5.5.3 Configuring Analog Signal Reference Source
5.5.4 Loading the Reference Source
5.6 Configuring System Parameters

List of Tables
Table 5-1 SRCU or SOCU board parameter
Table 5-2 LCIM board parameter
Table 5-3 TSOU board parameter
Table 5-4 CCOU board parameter
Table 5-5 Digital signal reference source parameter
Table 5-6 Parameter for setting the threshold of the majority vote
Table 5-7 SSM parameter
Table 5-8 Transport parameter
Table 5-9 Analog signal reference source parameter
Table 5-10 System parameter

Chapter 5 Data Configuration


5.1 About This Manual
This chapter introduces the data configuration of the maintenance terminal.
This chapter covers the following sections.
Section

Describes

5.2 Introduction

The data configuration of the maintenance


terminal

5.3 Displaying the Data


Configuration Window

How to display the data configuration window

5.4 Configuring the Board Data

How to configure the board data

5.5 Configuring the Reference


Source

How to configure the reference source data

5.6 Configuring System


Parameters

How to configure the system parameters

5.2 Introduction
There is no BITS configuration data on the maintenance terminal of the SYNLOCK V3. After an NE is selected and the data configuration window is displayed, the
maintenance terminal downloads the configuration data from the BITS. In this way, the data on the maintenance terminal can be consistent with that on the BITS.
You can also query the BITS configuration data through the data configuration window.

5.3 Displaying the Data Configuration Window


I. Description
This operation enables you to display the data configuration window.

II. Prerequisite
Before the operation, make sure that:
The maintenance terminal software is installed.
You have logged in to the system and BITS as a maintainer or an administrator.

l
l

III. Procedure
Step
1

Action
Double click the Data configuration node on the navigation tree to display the Select NE dialog box.

http://127.0.0.1:52199/hedex/pages/31180917/03%20(2009-08-14)/31180917/03%20(... 22/09/2014

05-Chapter 5 Data Configuration

Page 2 of 12

Step

Action
Select an NE, and click OK to display the Data configuration-Board Position Diagram dialog box as shown below.

5.4 Configuring the Board Data


5.4.1 Configuring the Clock Board in the Slot 0
I. Description
This operation enables you to configure the data of the clock board in the slot 0 in the main frame.

II. Prerequisite
Before the operation, make sure that:
The maintenance terminal software is installed.
You have logged in to the system and BITS as a maintainer or an administrator.

l
l

III. Procedure
Step

Action
In the Data configuration-Board Position Diagram dialog box, right click the slot 0 in the main frame, and select Add SRCU or
Add SOCU.

In the confirmation dialog box that appears, click OK.

The new board is displayed in the corresponding slot.


Select the SRCU or SOCU board, right click, and select Configure SRCU or Configure SOCU (here, take the SRCU board as
an example) to display a dialog box as shown below.

Set the related parameters, and click OK.

For details, see the Table 5-1.

In the confirmation dialog box that appears, click OK.

In the prompt dialog box that appears, click OK.

Select the configured board, right click and select Load SRCU.

In the confirmation dialog box that appears, click OK.

IV. Parameter description


Table 5-1 describes the parameters for configuring the SRCU or SOCU board.
Table 5-1 SRCU or SOCU board parameter
Parameter

Description
The type of the satellite card. The options are:

Satellite card type

l
l
l

GPS: The GPS satellite card


GLOGPS: The dual satellite card
NONE: No satellite card

The type of the input channel.


Input channel signal
type

The signal type for channel 1, 2, 3 and 4 can be E1,


1MHz, 2048 KHz, 5 MHz, 10 MHz or NONE.
The actual signal type of the satellite input channel is
1PPS and need not to be configured.

http://127.0.0.1:52199/hedex/pages/31180917/03%20(2009-08-14)/31180917/03%20(... 22/09/2014

05-Chapter 5 Data Configuration

Parameter

Page 3 of 12

Description
The test template for the input channel.
l

test template of
input channel

Test input channel

For channels 1, 2, 3, 4, and 1PPS signal MTIE/TDEV


test template: Wander tolerance, Wander generation
and Customize. Wander tolerance is recommended.
For the MITE/TDEV test template of satellite signals 1
and 2: Customized template for satellite signal and
Customize. Customized template for satellite signal
is recommended.
For the FREQ test template: Standard and Customize.
Standard is recommended.

Specifies whether to test the signal of the channels. The


channels those have input signals must be tested.

5.4.2 Configuring the Clock Board in the Slot 12


I. Description
This operation enables you to configure the data of the clock board in the slot 12 in the main frame.

II. Prerequisite
Before the operation, make sure that:
The maintenance terminal software is installed.
You have logged in to the system and BITS as a maintainer or an administrator.

l
l

III. Procedure
Step

Action
In the Data configuration-Board Position Diagram dialog box, right click the slot 12 in the main frame, and select Add SRCU
or Add SOCU.

In the confirmation dialog box that appears, click OK.

The new board is displayed in the corresponding slot.


Select the SRCU or SOCU board, right click, and select Configure SRCU or Configure SOCU (here, take the SOCU board as
an example) to display the Configure SOCU dialog box as shown below.

Double click the type field, and select the desired type of the satellite card (here, take GPS as an example) to display a dialog
box as shown below.

Set the related parameters, and click OK.

It is recommended that to set Visual satellite threshold to 1, and set Satellite mask angle to 5.

In the confirmation dialog box that appears, click OK.

In the Configure SOCU dialog box, click OK.

In the confirmation dialog box that appears, click OK.

In the prompt dialog box that appears, click OK.

10

Select the configured board, right click and select Load SOCU.

11

In the confirmation dialog box that appears, click OK.

5.4.3 Configuring the LCIM Board


I. Description
This operation enables you to configure the LCIM board in the main frame. Two LCIM boards are recommended.

II. Prerequisite
Before the operation, make sure that:
l

The maintenance terminal software is installed.

http://127.0.0.1:52199/hedex/pages/31180917/03%20(2009-08-14)/31180917/03%20(... 22/09/2014

05-Chapter 5 Data Configuration

Page 4 of 12

You have logged in to the system and BITS as a maintainer or an administrator.

III. Note
To configure the test template, note that:
In the standard template mode, the threshold point and value cannot be modified.
If the value input does not meet the requirement or is the same as another one, you must modify the value according to the system prompts.

l
l

IV. Procedure
Step
1
2

Action
In the Data configuration-Board Position Diagram dialog box, right click a slot from 110, and select Add LCIM.
In the confirmation dialog box that appears, click OK.
The new board is displayed in the corresponding slot.
Select the LCIM board, right click and select Configure LCIM to display the Configure LCIM dialog box as shown below.

Double click the drop-down list of the MTIE/TDEV test template of channel, and select Wander tolerance or Wander generation
(here, take the Wander tolerance as an example) to display a dialog box as shown below.

Query the threshold point and threshold value of the template, and click OK.
Double click the drop-down list of MTIE/TDEV test template of channel, and select Customize to display the Customize dialog
box as shown below.

Do one as follows to modify the threshold value.


7

l
l

Click the value and input the desired value directly.


Select a threshold value, and click Modify Threshold Value. In the dialog box that appears, modify the threshold point and
value and then click OK. In the confirmation dialog box that appears, click OK.

In the Customize dialog box, click OK.

http://127.0.0.1:52199/hedex/pages/31180917/03%20(2009-08-14)/31180917/03%20(... 22/09/2014

05-Chapter 5 Data Configuration

Page 5 of 12

Step

Action
In the confirmation dialog box that appears, click OK.
The procedure of configuring the FREQ test template is the same as that of configuring the MTIE/TDEV test template. The
difference lies in that there are only Standard template and Customize.

For details, see step 49.


Configure other parameters.

10

For details, see the Table 5-2.

11

In the Configure LCIM dialog box, click OK.

12

In the confirmation dialog box that appears, click OK.

13

In the confirmation dialog box that appears, click OK.

14

In the prompt dialog box that appears, click OK.

15

Select the configured board, right click and select Load LCIM.

16

In the confirmation dialog box that appears, click OK.

V. Parameter description
Table 5-2 describes the parameters for configuring the LCIM board.
Table 5-2 LCIM board parameter
Parameter

Description
The type of the LCIM board. The options are:

Output mode

l
l

INPUT: The input board


MEASURE: The test board

Here, select INPUT.


Board
active/standby

Channel type

It is available after the board type is configured as INPUT.


The options are BACKUP and NOBACKUP.
BACKUP is recommended.
The type of channel 18. The options are E1, 1MHz,
2048 KHz, 5 MHz, 10 MHz and NONE.
You must select the type according to the actual signal
type.
l

Test template of
channel

Test channel

For all the MTIE/TDEV test template of the channel:


Wander tolerance, Wander generation and
Customize. Wander tolerance is recommended.
For all the FREQ test template of the channel:
Standard template and Customize. Standard
template is recommended.

Specifies whether to test the signal of the channel. It is


recommended that all the channels that have input signals
should be tested.

5.4.4 Configuring TSOU Board


I. Description
This operation enables you to configure the TSOU board. Two TSOU boards are recommended.

II. Prerequisite
Before the operation, make sure that:
The maintenance terminal software is installed.
You have logged in to the system and BITS as a maintainer or an administrator.

l
l

III. Procedure
Step
1
2

Action
In the Data configuration-Board Position Diagram dialog box, right click a slot ranging from 110, and select Add TSOU.
In the confirmation dialog box that appears, click OK.
The new board is displayed in the corresponding slot.
Select the TSOU board, right click and select Configure TSOU to display the Configure TSOU dialog box as shown below.

Configure the related parameters.


For details, see the Table 5-3.

http://127.0.0.1:52199/hedex/pages/31180917/03%20(2009-08-14)/31180917/03%20(... 22/09/2014

05-Chapter 5 Data Configuration

Page 6 of 12

Step

Action
Click Configure Uniformly to display a dialog box as shown below.
The channels can be configured one by one or uniformly.

Select the signal type and status, and click Ok.

In the confirmation dialog box, click Ok.

In the Configure TSOU dialog box, click Ok.

In the confirmation dialog box that appears, click Ok.

10

In the prompt dialog box that appears, click Ok.

11

Select the configured board, right click and select Load TSOU.

12

In the confirmation dialog box that appears, click Ok.

IV. Parameter description


Table 5-3 describes the parameters for configuring the TSOU board.
Table 5-3 TSOU board parameter
Parameter

Description
The type of the TSOU board. The options are:
l

Output mode
l

1+1: The active and the standby boards send the signal
at the same time
1:1: Only the active board sends the signal

1:1 is recommended.
The type of the channel 120. The options are E1, 1 MHz,
2048 KHz, 5 MHz and 10 MHz.
Channel type

You can set the type as required. You can also set the
channels of the same output board to the same type for a
convenient management.

Channel blocking

Specifies whether to block the channel. The options are


ENABLE and DISABLE.
Set the parameter as required.

Channel name

The name of the channel. It can be configured one by one


or uniformly.

5.4.5 Configuring the CCOU Board


I. Description
This operation enables you to configure the CCOU board. Two CCOU boards are recommended.

II. Prerequisite
Before the operation, make sure that:
The maintenance terminal software is installed.
You have logged in to the system and BITS as a maintainer or an administrator.

l
l

III. Procedure
Step
1
2

Action
In the Data configuration-Board Position Diagram dialog box, right click a slot ranging from 110, and select Add CCOU.
In the confirmation dialog box that appears, click OK.
The new board is displayed in the corresponding slot.
Select the CCOU board, right click and select Configure CCOU to display the Configure CCOU dialog box as shown below.

Configure the related parameters.


For details, see the Table 5-4.

http://127.0.0.1:52199/hedex/pages/31180917/03%20(2009-08-14)/31180917/03%20(... 22/09/2014

05-Chapter 5 Data Configuration

Page 7 of 12

Step

Action
Click Configure Uniformly to display a dialog box as shown below.
The channels can be configured one by one or uniformly.

Select the signal type and status, and click Ok.

In the confirmation dialog box, click Ok.

In the Configure CCOU dialog box, click Ok.

In the confirmation dialog box that appears, click Ok.

10

In the prompt dialog box that appears, click Ok.

11

Select the configured board, right click and select Load CCOU.

12

In the confirmation dialog box that appears, click Ok.

IV. Parameter description


Table 5-4 describes the parameters for configuring the CCOU board.
Table 5-4 CCOU board parameter
Parameter

Description
The type of the TSOU board. The options are:
l

Output mode
l

1+1: The active and the standby boards send the signal
at the same time
1:1: Only the active board sends the signal

1:1 is recommended.
The type of the channel 120. The options are CC, E1, 1
MHz, 2048 KHz, 5 MHz and 10 MHz.
Channel type

You can set the type as required. You can also set the
channels of the same output board to the same type for a
convenient management.

Channel blocking

Specifies whether to block the channel. The options are


ENABLE and DISABLE.
Set the parameter as required.

Channel name

The name of the channel. It can be configured one by one


or uniformly.

5.4.6 Configuring TDRV Board


I. Description
This operation enables you to configure the TDRV board in the expansion frame. Two TDRV boards are recommended.

II. Prerequisite
Before the operation, make sure that:
The maintenance terminal software is installed.
You have logged in to the system and BITS as a maintainer or an administrator.

l
l

III. Note
To configure the expansion frame, note that:
Up to two expansion frames can be configured on the SYNLOCK V3 BITS.
Only the TDRV, TSOU and CCOU boards can be configured in the expansion frame.
You can directly add the TDRV board to the slot 0 or 12 of the expansion frame and need no configuration.

l
l
l

IV. Procedure
Step

Action

In the Data configuration-Board Position Diagram dialog box, click


1.

in the lower left corner to switch to the expansion frame

In the pane that appears, right click the slot 0 or 12, and select Add TDRV.
In the confirmation dialog box that appears, click OK.

The new board is displayed in the corresponding slot.

5.5 Configuring the Reference Source


5.5.1 Adding a Reference Source
I. Description
This operation enables you to add a reference source.

II. Prerequisite
Before the operation, make sure that:
l
l

The maintenance terminal software is installed.


You have logged in to the system and BITS as a maintainer or an administrator.

III. Procedure
Step

Action

http://127.0.0.1:52199/hedex/pages/31180917/03%20(2009-08-14)/31180917/03%20(... 22/09/2014

05-Chapter 5 Data Configuration

Step

Page 8 of 12

Action
Select Configuration > Reference Source from the main menu to display a dialog box as shown below.

& Note:
l

stands for the reference source of the digital signal.

stands for the reference source of the analog signal

Right click the blank area, and select Add Reference Source to display a dialog box as shown below.

Select the desired reference source, as shown in the following figure, and click Ok. If you select the PPS or SSR reference
source, the system prompts that no reference source type should be configured.

& Note:
l
l
l
l

CSSR1 stands for the SSR reference source of the clock board in slot 0.
CSSR2 stands for the SSR reference source of the clock board in slot 12.
CSCLK1CSCLK4 and C1PPS stand for the input reference sources of the clock board.
CLCIM1-1CLCIM1-8 and CLCIM2-1CLCIM2-8 stand for the input reference sources of the LCIM board.

In the Add Reference Source dialog box, click Ok.

In the confirmation dialog box that appears, click Ok.

In the prompt dialog box that appears, click Ok.

5.5.2 Configuring Digital Signal Reference Source


I. Description
This operation enables you to configure the reference source of the digital signal.

II. Prerequisite
Before the operation, make sure that:
The maintenance terminal software is installed.
You have logged in to the system and BITS as a maintainer or an administrator.

l
l

III. Procedure
Step
1

Action
Select Configuration > Reference Source from the main menu.
In the reference source list, select the digital signal reference source, right click, and select Configure Reference Source to
display the Reference Source dialog box as shown below.

Configure the related parameters.


For details, see the Table 5-5.

http://127.0.0.1:52199/hedex/pages/31180917/03%20(2009-08-14)/31180917/03%20(... 22/09/2014

05-Chapter 5 Data Configuration

Page 9 of 12

Step

Action
If Take part in the majority voting is set to Y, click Majority Voting to display a dialog box as shown below.

Select or input the threshold, and click Ok.

For details, see Table 5-6.

In the confirmation dialog box that appears, click Ok.


In the Reference Source dialog box, click SSM Parameter to display a dialog box as shown below.

Configure the related parameters, and click Ok.

For details, see the Table 5-7.

In the confirmation dialog box that appears, click Ok.


In the Reference Source dialog box, click Transport Param to display a dialog box as shown below.

10

Configure the related parameters, and click Ok.

11

For details, see the Table 5-8.

12

In the confirmation dialog box that appears, click Ok.

13

In the Reference Source dialog box, click Ok.

14

In the confirmation dialog box that appears, click Ok.


Load the reference source.

15

For details, see "5.5.4 Loading the Reference Source".

IV. Parameter description


Table 5-5 describes the parameters for configuring the digital signal reference source.
Table 5-5 Digital signal reference source parameter
Parameter
Signal name

Work as the active

Reference source level

Take part in the majority


voting

Description
The name of the reference source. You can set the
name as required.
Specifies whether set the reference to the active
one. The options are Y and N.
B e ca u se t h e d e vi ce g e n e r a ll y wo r k s i n t h e
intelligent mode, select N.
The level of the reference source. The value range
is 123.
This parameter is set according to the engineering
design and must be unique.
Specifies whether to set the reference source to be
involved in the majority voting. The options are Y
and N.
Y is recommended.

FREQ test result take part


in the control

MTIE test result take part in


the control

Specifies whether to set the FREQ test result to be


involved in the control. The options are Y and N.
Y is recommended.
Specifies whether to set the MITE test result to be
involved in the control. The options are Y and N.
Y is recommended.

http://127.0.0.1:52199/hedex/pages/31180917/03%20(2009-08-14)/31180917/03%20(... 22/09/2014

05-Chapter 5 Data Configuration

Page 10 of 12

Parameter

Description

TDEV test result take part


in the control

Specifies whether to set the TDEV test result to be


involved in the control. The options are Y and N.
Y is recommended.

Table 5-6 lists the parameter for setting the threshold of the majority vote.
Table 5-6 Parameter for setting the threshold of the majority vote
Parameter

Description
The threshold of the frequency deviation for the majority
vote of the reference source.

S e le ct o r I n p u t t h e
Threshold

For th e SO CU b oa rd , s ele c t t he t hr es h old a s


6000000 (E-12). That is, 6E-6.
For the SRCU board, select the threshold as 20000
(E-12). That is, 2E-8.

Table 5-7 describes the parameters for configuring the Synchronization Status Message (SSM).
Table 5-7 SSM parameter
Parameter
SSM Information

Description
Specifies whether the signal has the SSM. The options
are Y and N.
Set the parameter as required.

Specify the SSMB


position

Specifies the position of the SSMB if there is SSM


information. The value range is 48, indicating SA4SA8.
Set the parameter according to the actual SSM position
of the input signal.
l

Specify the SSM


threshold

If the input signal contains the SSM information and


the SSM value is less than the threshold. The SSM
alarm is generated. It is recommended to set the
threshold to the clock level of the device.
If the input signal contains no SSM information, the
specified SSM levels of the input channel are listed. It
is recommended to set the threshold to PRC if no
special requirement is put.

Table 5-8 describes the transport parameters.


Table 5-8 Transport parameter
Parameter

Description
The threshold of the Frame Alignment Signal (FAS). It is
recommended to set this parameter to 65535.

FAS threshold
FAS is involved in the
control

Specifies whether to set the FAS alarm level to be


involved in the control. The options are Y and N.
Y is recommended.
The threshold of the Out of Frame (OOF).

OOF threshold

It is recommended to set this parameter to 65535.

OOF take part in the


control

Specifies whether to set the OOF alarm level to be


involved in the control. The options are Y and N.
Y is recommended.
The threshold of the Bipolar Polarity Violation (BPV).

BPV threshold

It is recommended to set this parameter to 65535.

BPV is involved in the


control

Specifies whether to set the BPV alarm level to be


involved in the control. The options are Y and N.
Y is recommended.
The threshold of the Cyclical Redundancy Check (CRC).

CRC threshold

It is recommended to set this parameter to 65535.

CRC is involved in the


control

Specifies whether to set the CRC alarm level to be


involved in the control. The options are Y and N.
Y is recommended.
The threshold of the Alarm Indication Signal (AIS).

AIS threshold

It is recommended to set this parameter to 1.

AIS is involved in the


control

Specifies whether to set the AIS alarm level to be


involved in the control. The options are Y and N.
Y is recommended.

5.5.3 Configuring Analog Signal Reference Source


I. Description
This operation enables you to configure the reference source of the analog signal.

II. Prerequisite
Before the operation, make sure that:
The maintenance terminal software is installed.
You have logged in to the system and BITS as a maintainer or an administrator.

l
l

III. Procedure
Step
1

Action
Select Configuration > Reference Source from the main menu.

http://127.0.0.1:52199/hedex/pages/31180917/03%20(2009-08-14)/31180917/03%20(... 22/09/2014

05-Chapter 5 Data Configuration

Page 11 of 12

Step

Action
In the reference source list, select the analog signal reference source, right click, and select Configure Reference Source to
display the Reference Source dialog box as shown below.

Configure the related parameters.

For details, see the Table 5-9.


If Take part in the majority voting is set to Y, click Majority Voting to display a dialog box as shown below.

Select or input the threshold, and click Ok.

For details, see Table 5-6.

In the confirmation dialog box that appears, click Ok.

In the Reference Source dialog box, click Ok.

In the confirmation dialog box that appears, click Ok.


Load the reference source.

For details, see "5.5.4 Loading the Reference Source".

IV. Parameter description


Table 5-9 describes the parameters for configuring the analog signal reference source.
Table 5-9 Analog signal reference source parameter
Parameter

Description
The name of the reference source. You can set the
name as required.

Signal name

Work as the active

Reference source level

Take part in the majority


voting

Specifies whether set the reference to the active


one. The options are Y and N.
B e ca u se t h e d e vi ce g e n e r a ll y wo r k s i n t h e
intelligent mode, select N.
The level of the reference source. The value range
is 123.
This parameter is set according to the engineering
design and must be unique.
Specifies whether to set the reference source to be
involved in the majority voting. The options are Y
and N.
Y is recommended.

FREQ test result take part


in the control

MTIE test result take part in


the control

TDEV test result take part


in the control

Specify the SSM level

Specifies whether to set the FREQ test result to be


involved in the control. The options are Y and N.
Y is recommended.
Specifies whether to set the MITE test result to be
involved in the control. The options are Y and N.
Y is recommended.
Specifies whether to set the TDEV test result to be
involved in the control. The options are Y and N.
Y is recommended.
Specifies the SSM level of the analog input signal.
Set this parameter to PRC if no special requirement
is put.

5.5.4 Loading the Reference Source


I. Description
This operation enables you to load the reference source.

II. Prerequisite
Before the operation, make sure that:
The maintenance terminal software is installed.
You have logged in to the system and BITS as a maintainer or an administrator.

l
l

III. Procedure
Step
1

Action
Select Configuration > Reference Source from the main menu.

http://127.0.0.1:52199/hedex/pages/31180917/03%20(2009-08-14)/31180917/03%20(... 22/09/2014

05-Chapter 5 Data Configuration

Page 12 of 12

Step

Action

In the reference source list, right click a record, and select Load Reference Source, or right click the blank area, and select
Load All Reference Sources.

In the confirmation dialog box that appears, click Ok.

5.6 Configuring System Parameters


I. Description
This operation enables you to configure system parameters.

II. Prerequisite
Before the operation, make sure that:
The maintenance terminal software is installed.
You have logged in to the system and BITS as a maintainer or an administrator.

l
l

III. Procedure
Step

Action
Select Configuration > System Parameter from the main menu to display a dialog box as shown below.

Configure the related parameters, and click Set.

For details, see the Table 5-10.

In the confirmation dialog box that appears, click Ok.

Click Exit.

IV. Parameter description


Table 5-10 describes the system parameters.
Table 5-10 System parameter
Parameter
System work mode
The majority voting
result take part in the
control
SSM takes part in
selecting source

Output Signal SSMB


position

REF signal selection

Description
Specifies the work mode of the system. The options are
MAN and INT, indicating the manual mode and intelligent
mode respectively. It is INT by default.
Specifies whether to set the majority voting result to be
involved in the control. The options are Y and N.
Y is recommended.
Specifies whether to set the SSM to be involved in
selecting source. The options are Y and N.
Y is recommended.
Specifies the position of the SSMB in the E1 signal. The
value range is 48, indicating SA4SA8. It is SA4 by
default.
Set this parameter according to the opposite device
requirement.
S p e c if ie s t h e R e f e r e n c e I n d ic a t o r ( R EF ) f o r t h e
performance test. The signal can be the system input
signal, local vibrating signal of the clock board or the
output signal of the active clock board.
The output signal of the active clock board is select by
default. That is, CSCLKOUT.

Frame format of
output E1

Specifies the frame format of the E1 signal. The options


are CCS and CAS, indicating the Common Channel
Signaling and Channel Associated Signaling. It is CAS by
default.

Analog transparent
transmission signal
selection

Specifies an analog reference source to be the analog


transparent transmission signal of the system.

Select E1
Transparent
Transmission Signal

Dry Contact Mode


When Alarm Occurs
(0-Turns On, 1-Turns
Off)

Specifies an E1 reference source to be the E1 transparent


transmission signal of the system.
Select the 2048 kHz signal of the LCIM whose priority
level is the highest one.
Specifies the control mode of the circuit Boolean value
between the BITS device and the remote alarm device.
Two options 0 and 1 are available: 0 indicates "generate
an alarm when it is turned on" and 1 "generate an alarm
when it is tu rned off ". You c an se t this pa rameter
according to whether the alarm of the remote alarm
device is indicated by turn-on or turn-off.