Beruflich Dokumente
Kultur Dokumente
UPC20
C on t ro l S y s t em A c c e s s or ie s
Electroluminescent and LCD Control Panels are warranted for three (3) years, except for the display and touch
overlay components that are warranted for a period of one (1) year.
Disk drive mechanisms, pan/tilt heads, power supplies, MX Series products, and KC Series products are
warranted for a period of one (1) year.
Unless otherwise specified, OEM and custom products are warranted for a period of one (1) year.
Batteries and incandescent lamps are not covered under the warranty.
This warranty extends only to products purchased directly from AMX Corporation or an Authorized AMX Dealer.
AMX Corporation is not liable for any damages caused by its products or for the failure of its products to perform.
This includes any lost profits, lost savings, incidental damages, or consequential damages. AMX Corporation is not
liable for any claim made by a third party or by an AMX Dealer for a third party.
This limitation of liability applies whether damages are sought, or a claim is made, under this warranty or as a tort
claim (including negligence and strict product liability), a contract claim, or any other claim. This limitation of
liability cannot be waived or amended by any person. This limitation of liability will be effective even if AMX
Corporation or an authorized representative of AMX Corporation has been advised of the possibility of any such
damages. This limitation of liability, however, will not apply to claims for personal injury.
Some states do not allow a limitation of how long an implied warranty last. Some states do not allow the limitation or
exclusion of incidental or consequential damages for consumer products. In such states, the limitation or exclusion of
the Limited Warranty may not apply. This Limited Warranty gives the owner specific legal rights. The owner may
also have other rights that vary from state to state. The owner is advised to consult applicable state laws for full
determination of rights.
EXCEPT AS EXPRESSLY SET FORTH IN THIS WARRANTY, AMX CORPORATION MAKES NO
OTHER WARRANTIES, EXPRESSED OR IMPLIED, INCLUDING ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. AMX CORPORATION
EXPRESSLY DISCLAIMS ALL WARRANTIES NOT STATED IN THIS LIMITED WARRANTY. ANY
IMPLIED WARRANTIES THAT MAY BE IMPOSED BY LAW ARE LIMITED TO THE TERMS OF THIS
LIMITED WARRANTY.
Table of Contents
Product Information................................................................ 1
Definitions
Specifications
P1 Circuit Connections
Installation .............................................................................. 9
Table of Contents
ii
Table of Contents
Product Information
The UPC20 Universal Power Controller is a dual 20 amp AC power and Motor
Controller designed for conduit installation. The UPC20 is housed in a compact metal
wall-mountable enclosure and can be configured for a wide variety of power and
motor control modes. Low voltage contact-closure or open collector inputs allow
control from simple wall panels and/or remote systems. A test switch with an LED
indicator for each relay provides for local control and status information.
All functions and capabilities of the UPC20 are listed on the circuit board inside the
enclosure. Figure 1 and Figure 2 show the high voltage wiring and control features.
Figure 3 lists the specifications.
Definitions
The following are definitions of terms used in this manual.
Momentary Power
Latching Power
Relay contacts are toggled (from open to closed and
closed to open) each time a closure from input to common is momentarily
pulsed.
Product Information
Figure 1
UPC20 Universal
Power/Motor Controller
UPC20 20 A
motor and power
control unit
High voltage
terminal and wiring
arrangement label
Product Information
Figure 2
230 high-voltage
wiring connectors
S1
1
P1
115
115V
230
T1
K2
K1
T1
Transformer
230 high-voltage
wiring connectors
PB1 PB2
R8
S2
MOTOR
TIME
DELAY
ON
1 2 3 4
MOTOR TIME
DELAY
Test switches w/
status LEDs
P2
6
Jumper (JP1)
Low voltage and
remote control wiring
DIP switch (S2)
Specifications
Figure 3
UPC20 Specifications
UPC20 Specifications
Power
Includes
Product Information
Caution
Switch S2 is set for an
inoperative mode. Set the
switches as needed for the
required active control mode.
Product Information
Control Ports
Set this switch according to the high voltage wiring that will
be connected to terminals 5 and 6 on P1. See P1 Circuit
Connections. Set switch S1 to the line input voltage value
used before applying power to the UPC20.
Transformer (T1)
Jumper (JP1)
Enclosure
Dimensions (HWD)
Weight
Options
ATTENTION INSTALLER
Figure 4
UPC20 inoperative mode
warning label
P1 Circuit Connections
P1 terminals 5 and 6 are connections for 115/230 VAC to power the circuit board
electronics. For 277 VAC high voltage wiring, you can use these terminals separately
with 115/230 VAC input or provide 12 VDC to the board from the low voltage
terminal block, P2.
K1 and K2 are the power and motor control relay connections to P1 terminals 1 and 2,
and 3 and 4, respectively. Each relay is capable of switching the following loads:
Jumpers include one 22 gauge and one 14 gauge wired to supply board power at
115/230 VAC and to connect the common terminals of the relays. The jumpers are
cut as needed according to the wiring options selected.
Figure 5
Neut
Load
or
Motor
#1
Caution
When cutting the jumpers, be
sure the cut ends cannot
touch each other or any other
component in the UPC20.
5
Board
Power
1
Terminal
Block P1
Line
Product Information
Figure 6
Line Load
#2
#2
Line Load
#1
#1
Board
Power
Cut
Line
1
Terminal
Block P1
Figure 7
Low voltage and 277 VAC
high voltage wiring
Caution
3 4
12 VDC
277 VAC
Line
Neut
Line
Load
#2
#2
4
Cut
Line
#1
Load
#1
5 6
External Power to
Circuit Board
Board
Power
3
Cut
Line
1
Terminal
Block P1
Product Information
The motor will automatically turn off when the time determined by the motor time
delay potentiometer, R8, expires. Delay time can range from 0.5 to 90 seconds. It is
typically set to allow direction limit switches to operate, or to reach the desired
position.
Figure 8
Motor Control Mode DIP
Switch S2 Positions
Control Mode
On
On
Off
On
Single button
Off
Off
Off
On
2-button
Figure 9
Control Mode
Common
Up
Down
Stop
N/A
2-, 3-button
Common
Up/Stop/Down
N/A
N/A
N/A
Single button
Two-Button Mode operates with two pushbuttons, one for Up and one for
Down.
Control Mode
On
On
On
On
Momentary On/Off
Off
On
On
On
Latching On/Off
On
Off
Off
On
On
Off
On
On
#1 Momentary, #2 Latching
Off
Off
On
On
#1 Latching, #2 Momentary
Product Information
Figure 11
Common
#1 On/Off
#2 On/Off
Common
#1 On
#2 On
Product Information
5
N/A
#1 Off
Control Mode
N/A
#2 Off
Installation
To install the UPC20 unit:
1. Mount the UPC20 on a wall or solid surface in the location where it will be used.
requirements using 0.5 inch (12.7 mm) or 0.75 inch (19.05 mm) knockouts.
5. Connect high voltage wiring. Run high voltage wiring for motor or control
options.
6. Connect control wiring.
a. Set control mode DIP switch S2 and control jumper JP1. Refer to the Control
Installation
brussels dallas los angeles mexico city philadelphia shanghai singapore tampa toronto york
3000 research drive, richardson, TX 75082 USA 469.624.8000 800.222.0193 fax 469.624.7153 technical support 800.932.6993
041-004-1077 9/01 2001 AMX Corporation. All rights reserved. AMX, the AMX logo, the building icon, the home icon, and the light bulb icon are all trademarks of AMX Corporation.
AMX reserves the right to alter specifications without notice at any time. *In Canada doing business as Panja Inc.
AMX reserves the right to alter specifications without notice at any time.