Sie sind auf Seite 1von 6

UPS

41-9027

Valve Regulated Lead Acid Battery


Designed for UPS Standby Power Applications.

FEATURES & BENEFITS


10 year design life @ 25C
Absorbent Glass Mat (AGM)
technology for efficient gas
recombination of up to 99% and
freedom from electrolyte maintenance.

Proprietary Fixed Orifice Plate Pasting


technology applying active materials
on both sides of the grid for consistent
cell-to-cell performance, higher
capacity and uniform grid protection.

3 Year Warranty (refer Dynasty warranty


card, 41-9026)

Thermally welded case-to-cover bond


to eliminate leakage.

Patented Long Life Alloy having the


lowest calcium levels in the industry minimizing grid growth, reducing
gassing, and extending battery life.

Can be operated in any orientation.


Upright, side or end mounting
recommended.
Not restricted for air transport Complies with IATA/ICAO Special
Provisions A67.

Patented UL Recognized Flamearresting vents in each cell for safety


and long life.
Designed with the same recombination,
thermal runaway prevention, gassing
and flame retardant characteristics of
the Bellcore 4228 compliant Dynasty
Telecom products.
Flame retardant polypropylene case
and cover compliant with UL 1778

TECHNICAL DATA

Model
UPS12-100MR

Voltage
12

5
172

Watts Per Cell @ 77F (25C)


Operating Time (in minutes) to 1.67 Volts per Cell
10
15
20
30
40
45
50
117
91
75
57
47
43
39

UPS12-150MR

12

288

192

148

120

89

71

65

60

UPS12-210MR

12

376

257

206

170

125

101

92

85

UPS12-300MR

12

550

382

300

244

179

144

131

121

UPS12-350MR

12

620

440

350

290

217

171

155

UPS12-400MR

12

720

505

400

325

237

189

172

UPS12-490MR

12

773

590

488

412

317

256

UPS12-540MR

12

868

654

537

450

344

UPS6-620MR

940

750

620

525

410

Not restricted for surface transport Classified as non-hazardous material


as related to DOT-CFR Title 49 parts
171-189.
Not restricted for water transport Classified as non-hazardous material
per IMDG Amendment 27.

90
24

Weight
lbs
21

Weight
kg
10

51

36

27.3

12.4

73

52

40

18

105

76

58.4

26.5

141

122

87

67.4

30.5

158

136

98

75.8

34.4

236

218

189

136

100

45

277

252

230

198

139

100

45

333

309

285

245

173

72

33

60
35

UPS
SPECIFICATIONS
Operating Temperature Range
with temperature compensation

Discharge: -40F (-40C) to +160F (71C)


Charge: -10F (-23C) to +140F (60C)

Nominal Operating Temperature Range

+74F (-23C) to +80F (27C)

Recommended Maximum Charging


Current Limit

C/5 amperes @ 20hr rate

Float Charging Voltage

13.65 1.5 VDC average per 12V unit (6.75 to 6.90 per 6V unit)

Maximum AC Ripple (Charger)

0.5% RMS or 1.5% P-P of float charge voltage recommended for best results.

Self Discharge

Up to 6 months at 25C and then a freshening charge is required. For higher temps,
the time interval will increase. freshening charge is required.
For higher temperatures the time interval will be shorter.
For lower temperatures time interval will decrease equalization charge.

Equalize charge and


cycle service voltage

14.40 to 14.80 VDC average per 12V unit @ 77F (25C) (7.20 to 7.40 VDC per 6V unit.)

Terminal: Flag

0.22 in. clearance hole to accept 0.1875 in. bolt (UPS12-100MR)

Terminal: Inserted

Threaded copper alloy insert terminal to accept


10-32 UNF bolt (UPS12-150MR, UPS12-210MR)
1
4-20 UNC bolt (UPS12-300MR, UPS12-350MR, UPS12-400MR, UPS12-490MR, UPS12-540MR, UPS6-620MR)

Terminal Hardware Annual Retorque

32 in.-lbs (3.48 N-m)(UPS12-100MR)

Terminal Hardware Initial Torque:


Inserted Terminal

40 in.-lbs. (4.5 N-m)(UPS12-100MR)


25 in.-lbs. (2.8 N-m) (UPS12-150MR, UPS12-210MR)
110 in.-lbs. (12.4 N-m) (UPS12-300MR, UPS12-350MR, UPS12-400MR, UPS12-490MR, UPS12-540MR, UPS6-620MR)

DIMENSIONS
Battery Termination
UPS12-100MR

UPS12-150MR

1.33
33.88

0.75
19.0

7.54
(191.4)

5.19
(131.9)

5.02
6.52
(127.6) (165.7)

6.80
(172.7)

9.0
UPS12-210MR (228.6)

8.86
(225.1)

5.48
(139.2)

5.31
7.89
(134.8) (200.3)

8.07
(205.1)

10.27
(260.9)

10.17
(258.4)

6.83
(173.4)

6.65
7.89
(168.9) (200.3)

8.01
(203.5)

12.04
UPS12-350MR (305.8)

11.95
(303.5)

6.83
(173.4)

6.65
7.94
(168.9) (201.6)

8.06
(204.8)

13.42
UPS12-400MR (340.9)

12.75
(323.7)

6.80
(172.7)

6.54
8.40
(166.0) (213.2)

8.52
(216.4)

UPS12-490MR

13.57
UPS12-540MR (344.7)

12.74
(323.6)

6.80
(172.7)

6.63
10.81
(168.4) (274.5)

10.93
(277.7)

12.63
(320.8)

12.51
(317.8)

6.97
(177.0)

6.83
8.82
(173.4) (224.0)

8.94
(227.2)

1.13
28.70

1/4-20 UNC

1.22
31.10

1/4-20 UNC

0.67
17.1

1.33
33.7
0.13
3.2

UPS6-620MR

0.50
12.62

1/4-20 UNC

1.22
31.10

0.13
3.18

7.76
UPS12-150MR (197.1)

UPS12-490MR/UPS12-540MR

0.13
3.18

6.86
(174.3)

1/4-20 UNC

0.98
24.9

0.19
4.7

0.19
4.7

5.07
6.37
(128.8) (161.7)

1.31
33.32

5.17
(131.3)

UPS12-400MR

0.13
3.18

6.45
(163.7)

UPS12-350MR

1.33
33.68

0.13
3.18

6.54
UPS12-100MR (166.2)

UPS6-620MR

0.87
22.2

0.50
12.62

#10-32 UNF

0.18
4.67

UPS12-300MR

UPS 12-300MR

1.73
44.04

0.64
16.18

#10-32 UNF

1.31
33.32

0.66
16.6

0.25
6.42

0.2
5.5 2
6

0.50
12.70

UPS12-210MR

*All dimensions in millimeters. All dimensions are for reference only. Contact a C&D Representative for complete dimension information.

1/4-20 UNC

UPS
UPS12-100MR
Constant Power Discharge Ratings - Watts Per Cell @ 77F (25C)
Operating Time to End Point Voltage (in minutes)
End Point
Volts/Cell
1.75
1.70
1.67
1.65
1.60

5
158
168
172
174
179

10
111
115
117
118
119

15
87
90
91
91
92

20
73
75
75
76
76

30
56
57
57
57
58

40
46
47
47
47
47

45
42
43
43
43
43

50
39
40
40
40
40

60
34
35
35
35
35

90
24
24
24
25
25

Constant Current Discharge Ratings - Amperes @ 77F (25C)


Operating Time to End Point Voltage (in hours)
End Point
Volts/Cell
1.90
1.85
1.80
1.75

.083
51.1
62.8
72.3
80.0

.25
33.0
38.4
42.1
44.3

.50
22.4
25.3
27.1
28.1

.75
18.2
20.5
21.8
22.5

1
14.0
15.6
16.4
16.9

2
6.30
9.10
9.50
9.75

3
6.05
6.60
6.86
7.00

5
3.94
4.29
4.45
4.53

8
2.62
2.85
2.95
3.00

10
2.14
2.33
2.41
2.45

12
1.82
1.98
2.05
2.08

20
1.14
1.24
1.28
1.30

24
0.96
1.05
1.08
1.10

72
0.34
0.37
0.38
0.39

100
0.24
0.26
0.27
0.28

Note: Batteries to be mounted with 0.5 in. (1.25 cm) spacing minimum and free air ventilation. Specifications subject to change without notification.

UPS12-150MR
Constant Power Discharge Ratings - Watts Per Cell @ 77F (25C)
Operating Time to End Point Voltage (in minutes)
End Point
Volts/Cell
1.75
1.70
1.67
1.65
1.60

5
270
282
288
292
296

10
182
188
192
196
200

15
141
144
148
150
152

20
115
118
120
122
123

30
86
87
89
90
91

40
69.0
70.0
71.1
71.8
72.5

45
63.0
63.9
64.9
65.3
66.0

50
58.0
58.8
59.5
60.0
60.5

60
49.7
50.4
51.0
51.5
51.8

90
35.0
35.5
36.0
36.3
36.5

20
1.65
1.69
1.73

24
1.39
1.42
1.45

72
0.47
0.48
0.49

50
83.0
84.2
85.0
85.4
86.0

60
71.8
72.8
73.3
73.8
74.2

90
51.0
52.0
52.4
52.6
52.8

20
2.50
2.63
2.67

24
2.10
2.21
2.24

72
0.73
0.76
0.77

Constant Current Discharge Ratings - Amperes @ 77F (25C)


Operating Time to End Point Voltage (in hours)
End Point
Volts/Cell
1.85
1.80
1.75

1
22.5
23.8
25.2

2
12.5
13.1
13.7

3
8.80
9.20
9.52

5
5.68
5.90
6.05

8
3.76
3.90
4.00

10
3.10
3.21
3.29

12
2.63
2.72
2.78

Note: Batteries to be mounted with 0.5 in. (1.25 cm) spacing minimum and free air ventilation. Specifications subject to change without notification.

UPS12-210MR
Constant Power Discharge Ratings - Watts Per Cell @ 77F (25C)
Operating Time to End Point Voltage (in minutes)
End Point
Volts/Cell
1.75
1.70
1.67
1.65
1.60

5
340
366
376
380
392

10
240
252
257
259
261

15
195
201
206
207
209

20
164
168
170
171
172

30
121
123
125
126
127

40
98
99
101
101
102

45
90
91
92
93
93

Constant Power Discharge Ratings - Amperes @ 77F (25C)


Operating Time to End Point Voltage (in hours)
End Point
Volts/Cell
1.85
1.80
1.75

1
33.0
35.0
36.5

2
18.7
19.5
20.6

3
13.3
13.9
14.5

5
8.60
9.20
9.40

8
5.78
6.10
6.23

10
4.74
5.02
5.09

12
4.02
4.25
4.30

Note: Batteries to be mounted with 0.5 in. (1.25 cm) spacing minimum and free air ventilation. Specifications subject to change without notification.

UPS
UPS12-300MR
Constant Power Discharge Ratings - Watts Per Cell @ 77F (25C)
Operating Time to End Point Voltage (in minutes)
End Point
Volts/Cell
1.75
1.70
1.67
1.65
1.60

5
496
530
550
566
580

10
360
373
382
387
391

15
282
294
300
303
306

20
234
240
244
246
248

30
174
177
179
181
183

40
140
142
144
146
147

45
128
130
131
133
134

50
118
120
121
122
123

60
103
104
105
106
107

90
74
75
76
77
78

20
3.60
3.80
3.89

24
3.03
3.18
3.25

72
1.05
1.08
1.10

50
137
140
141
144
145

60
118
120
122
123
125

90
85
86
87
88
89

20
4.40
4.55
4.65

24
3.71
3.83
3.90

72
1.29
1.32
1.34

50
154
156
158
160
161

60
133
135
136
137
138

90
96
97
98
99
100

20
4.77
4.99
5.10

24
4.00
4.18
4.27

72
1.38
1.43
1.46

Constant Current Discharge Ratings - Amperes @ 77F (25C)


Operating Time to End Point Voltage (in hours)
End Point
Volts/Cell
1.85
1.80
1.75

1
48.4
50.7
52.5

2
27.1
28.3
29.0

3
19.6
20.3
20.6

5
12.6
13.1
13.4

8
8.34
8.81
9.13

10
6.85
7.27
7.50

12
5.80
6.15
6.35

Note: Batteries to be mounted with 0.5 in. (1.25 cm) spacing minimum and free air ventilation. Specifications subject to change without notification.

UPS12-350MR
Constant Power Discharge Ratings - Watts Per Cell @ 77F (25C)
Operating Time to End Point Voltage (in minutes)
End Point
Volts/Cell
1.75
1.70
1.67
1.65
1.60

5
540
596
620
640
672

10
410
425
440
455
470

15
327
337
350
360
370

20
274
283
290
298
303

30
205
211
217
219
222

40
164
167
171
173
175

45
149
152
155
157
159

Constant Current Discharge Ratings - Amperes @ 77F (25C)


Operating Time to End Point Voltage (in hours)
End Point
Volts/Cell
1.85
1.80
1.75

1
53.0
59.0
63.0

2
31.0
33.5
35.1

3
22.1
23.7
24.8

5
14.8
15.6
16.1

8
10.08
10.63
11.00

10
8.34
8.74
9.00

12
7.08
7.42
7.58

Note: Batteries to be mounted with 0.5 in. (1.25 cm) spacing minimum and free air ventilation. Specifications subject to change without notification.

UPS12-400MR
Constant Power Discharge Ratings - Watts Per Cell @ 77F (25C)
Operating Time to End Point Voltage (in minutes)
End Point
Volts/Cell
1.75
1.70
1.67
1.65
1.60

5
616
680
720
740
770

10
461
490
505
515
525

15
377
390
400
406
412

20
312
319
325
329
333

30
230
234
237
239
241

40
184
187
189
191
193

45
168
170
172
174
175

Constant Current Discharge Ratings - Amperes @ 77F (25C)


Operating Time to End Point Voltage (in hours)
End Point
Volts/Cell
1.85
1.80
1.75

1
56.0
62.0
68.0

2
33.0
35.3
38.0

3
23.9
25.3
27.0

5
15.8
16.6
17.6

8
10.8
11.4
11.9

10
8.90
9.44
9.80

12
7.58
8.02
8.30

Note: Batteries to be mounted with 0.5 in. (1.25 cm) spacing minimum and free air ventilation. Specifications subject to change without notification.

UPS
UPS12-490MR
Constant Power Discharge Ratings - Watts Per Cell @ 77F (25C)
Operating Time to End Point Voltage (in minutes)
End Point
Volts/Cell
1.75
1.70
1.67
1.65
1.60

5
660
740
773
800
840

10
525
570
590
614
644

15
444
472
488
500
513

20
385
401
412
418
428

30
300
310
317
322
327

40
245
252
256
260
264

45
224
231
236
238
241

50
208
214
218
220
222

60
183
186
189
191
192

90
133
135
136
137
138

20
6.58
6.79
6.96

24
5.53
5.70
5.84

72
1.93
1.99
2.03

50
220
226
230
234
237

60
190
193
198
200
202

90
136
137.5
139
141
143

20
6.35
6.94
7.20
7.35

24
5.35
5.88
6.06
6.17

72
1.85
2.00
2.07
2.11

60
242
243
245
248
250

90
168
170
173
176
178

Constant Current Discharge Ratings - Amperes @ 77F (25C)


Operating Time to End Point Voltage (in hours)
End Point
Volts/Cell
1.85
1.80
1.75

1
80.9
85.5
90.3

2
47.2
50.9
53.2

3
34.4
36.3
37.8

5
22.5
23.5
24.2

8
15.0
15.5
16.1

10
12.3
12.8
13.2

12
10.5
10.9
11.2

Note: Batteries to be mounted with 0.5 in. (1.25 cm) spacing minimum and free air ventilation. Specifications subject to change without notification.

UPS12-540MR
Constant Power Discharge Ratings - Watts Per Cell @ 77F (25C)
Operating Time to End Point Voltage (in minutes)
End Point
Volts/Cell
1.75
1.70
1.67
1.65
1.60

5
723
825
868
904
952

10
564
625
654
679
696

15
472
512
537
554
564

20
405
432
450
459
465

30
320
334
344
350
354

40
261
270
277
282
284

45
239
247
252
256
258

Constant Current Discharge Ratings - Amperes @ 77F (25C)


Operating Time to End Point Voltage (in hours)
End Point
Volts/Cell
1.90
1.85
1.80
1.75

1
75.0
85.0
90.0
95.0

2
44.0
49.5
53.0
56.0

3
32.0
35.8
38.0
39.9

5
21.4
23.4
24.6
25.6

8
14.4
15.8
16.4
16.9

10
11.9
13.0
13.6
13.9

12
10.1
11.1
11.5
11.8

Note: Batteries to be mounted with 0.5 in. (1.25 cm) spacing minimum and free air ventilation. Specifications subject to change without notification.

UPS6-620MR
Constant Power Discharge Ratings - Watts Per Cell @ 77F (25C)
Operating Time to End Point Voltage (in minutes)
End Point
Volts/Cell
1.75
1.70
1.67
1.65
1.60

5
840
890
940
950
1000

10
680
720
750
760
790

15
575
600
620
630
650

20
500
520
525
532
550

30
395
405
410
414
420

40
320
332
333
335
340

45
297
306
309
311
315

50
275
280
285
288
290

Constant Current Discharge Ratings - Amperes @ 77F (25C)


Operating Time to End Point Voltage (in hours)
End Point
Volts/Cell
1.90
1.85
1.80
1.75

.083
250
332
418
454

.25
207
248
288
312

.50
149
174
196
208

.75
122
142
158
166

1
94.0
110
120
123

2
57.7
62.7
68.0
69.5

3
42.0
45.5
48.3
50.0

5
27.9
30.0
31.6
32.4

8
19.0
20.3
21.3
22.0

10
15.8
16.9
17.6
18.2

12
13.5
14.5
15.2
15.6

20
8.70
9.30
9.80
10.0

Note: Batteries to be mounted with 0.5 in. (1.25 cm) spacing minimum and free air ventilation. Specifications subject to change without notification.

24
7.31
7.84
8.21
8.38

72
2.51
2.73
2.83
2.87

100
1.82
1.98
2.05
2.08

UPS

High Rate Max Part Number

Manufacturer Approved Premium Replacement for:

UPS12-100MR
UPS12-150MR
UPS12-210MR
UPS12-300MR
UPS12-350MR
UPS12-400MR
UPS12-490MR
UPS12-540MR
UPS6-620MR

UPS12-100FR
UPS12-140FR & MR12-150
UPS12-170FR, UPS12-200FR & MR12-210
UPS12-270FR & MR12-300
UPS12-310FR & MR12-350
UPS12-370FR & MR12-400
UPS12-475FR & MR12-490
UPS12-530FR & MR12-540
UPS6-620FR

Also Available

UPS CABINET SOLUTIONS

SITES THAT USE UPS HIGH


RATE MAX BATTERIES INCLUDE:
Data Centers
Network Operations Centers
Industrial Process Control Facilities
Internet Housing Sites
Semiconductor Manufacturing
Banks & Financial Markets
Power Generation Plants
Hospitals & Testing Laboratories
Emergency 911 response centers

Any data, descriptions or specifications presented herein are subject to revision by C&D Technologies, Inc. without notice.
While such information is believed to be accurate as indicated herein, C&D Technologies, Inc. makes no warranty and
hereby disclaims all warranties, express or implied, with regard to the accuracy or completeness of such information. Further,
because the product(s) featured herein may be used under conditions beyond its control, C&D Technologies, Inc. hereby
disclaims all warranties, either express or implied, concerning the fitness or suitability of such product(s) for any
particular use or in any specific application or arising from any course of dealing or usage of trade. The user is solely
responsible for determining the suitability of the product(s) featured herein for users intended purpose and in users specific application.
Copyright 2006 C&D TECHNOLOGIES, INC.

Printed in U.S.A.

41-9027

5M/1006/TN