Beruflich Dokumente
Kultur Dokumente
:
:
:
:
:
:
:
:
: 40 to 3000 C
Includes of:
a.
Training
b.
Original Operasional manual (plus bahasa indonesia)
c.
Guarantee min. A year
d.
Installation
e.
Factory Certificate
f.
Blower + Vent + Dusting (2 set)
g.
Vapor Generator accessory (pump units; gas liquid separator; quartz cell;
reagent container; tubing, Flow Through Mercury Cell and spares kit)
h.
Hollow Cathode Lamps + Standard Solution for : Pb, Hg, Cd, Zn, As, Mg, Ca, Na,
K,Cu, Fe, Cr, Se, Sn, Ag (15 buah)
i.
Argon gas with tank & regulator (1 set)
j.
C2H2 gas with tank & regulator (1 set)
k.
N20 gas with tank & regulator (1 set)
ENTITY
Unit
AMOUNT
1
l.
m.
n.
o.
p.
q.
r.
2
LSMSMS *)
Specifications :
MASS SPECTROMETRY
a. Ion Sources
b. Ion Sources Transfer Optics
c. Detector
d. Vacuum System
e. Mass range
f. Scan Speed
g. Mass resolution
h. Mass sensitivity
Unit
POMPA
a. Type
b. Flow rate range
c. Flow rate precision
d. Flow rate accuracy
e. Maximum operating pressure
: Quartenary
: minimum 0,010 to 2,000 ml/min
: 0,075 % RSD
: 1,0 %
: 8500 psi or greater
AUTOSAMPLER
a. Injection volume
b. Injection precision
c. Sampel capacity
d. Sample carryover
:
:
:
:
OVEN KOLOM
Column temperature range
: 20 to 90 C or greater
0,1 to 10,0 L
1 % RSD
min 90
< 0,005 %
Hardware
Software
LIBRARY compatible with system
N2 generator min 20 L/sec, with internal compressor
Ar gas + cylinder + regulator, tubibg, connector, reducer
UPS min 6 KVA
Magnetic Switch
Sample Cone
Solvent for 1 year :
Methanol 4 x 2,5 L
Acetonitril 2 x 2,5 L
NH4OH
Formic Acid 1 L
Includes of:
1. Installation
2. Training
3. Performance Test
4. After Sales Support
5. Factory Certificate
6. Guarantee 1 year
7. Spare Part Availability min. 5 year
8. Original manual book
9. Column C18
10. Column C8
11. Guard column for C 18
12. Guard column for C 8
13. Pre Column Filter Holder (fitting included)
14. 0,2 m Filter Cartridge, 5 / pk
15. Tube 50 ml /AOAC-acetat
16. Tube 2 ml- AOAC/C18
17. Solvent Clarification Kit with pump 220 V/50 Hz
18. Membran filter diameter 25 mm, 0,2 m ; 50 /pk
19. Sampel vial min 1 ml (100 pc/pk)
:
:
:
:
:
:
:
:
:
:
:
min 3 pcs
min 3 pcs
min 3 pkgs
min 3 pkgs
min 1 pk
min 1 pk
min 1 pk
min 1 pk
min 1 kit
min 3 pkgs
min 3 pkgs
Unit
:
:
:
:
:
:
:
1 unit
minimal 1 unit
1 unit
1 unit
3 unit
1 set
minimal 1 unit
: to 450 C
: up to 50 C or more cooler
: minimum 1
: 1:7500 or better
: 0 - 200 mL/min or better
: up to 400 C or greater
4 Detectors
Flame Ionization Detector (FID)
Specification :
a. Temperature range
: up to 400C or greater
: Up to 400oC or greater
: Up to 350oC or greater
5 a. Hardware
Minimum Intel Processor core I3, Windows XP, Hard Disk min. 120 GB, RAM min 2 GB, CDROM
Drive, DVD/CD Writer, LCD Monitor 17", Color printer.
b. Software :
- Compatible with Windows XP
- Data Acquisition
- Hardware Functions
- Data Processing and Analysis
- Data Storage
7 Autoinjector
a. number of vials
: min 12 or greater
8 Accessories :
1. Hydrogen gas
2. Helium Gas
3. Compress Air
4. Regulator for gases
5. 10 mL screw vial
6. Capillary Column
7. UPS min 5 KVA
8. GC Data Systems
9. Driver for SW
10. Gas Clean Filter
9. The system includes of :
1. Instalation
2. Training
3. Dust Cover
4. Guarantee min. 1 year
5. Spare Part Availability min. 5 year
6. Original operation manual
7. Factory Certificate
8. Tool Kit
:
:
:
:
:
:
:
:
:
:
1 pcs
1 pcs
1 pcs
3 pcs
1 pcs
2 pcs
1 pcs
1 pcs
1 pcs
1 pcs
Unit
:
:
:
:
:
:
:
1 unit
min 1 unit
1 unit
1 unit
3 unit
1 set
min 1 unit
: to 450 C
: up to 50 C or more cooler
: minimum 1
: 1:7500 or better
: 0 -200 mL/min or better
: up to 400 C or greater
4 Detectors
Flame Ionization Detector (FID)
Specification :
a. Temperature range
: up to 400C or greater
a. Temperature range
: Up to 400oC or greater
: Up to 350oC or greater
5 a. Hardware
Minimum Intel Processor core I3, Windows XP, Hard Disk min. 120 GB, RAM min 2 GB, CDROM Drive, DVD/CD Writer, LCD Monitor 17", Color printer.
b. Software :
a. Compatible with Windows XP
b. Data Acquisition
c. Hardware Functions
d. Data Processing and Analysis
e. Data Storage
7 Autoinjector
a. number of vials
: min 12 or greater
8 Accessories :
1. Hydrogen gas
2. Helium Gas
3. Compress Air
4. Nitrogen Gas
5. Regulator for gases
6. 10 mL screw vial
7. Capillary Column
8. UPS min 5 KVA
9. GC Data Systems
10. Driver for SW
11. Gas Clean Filter
:
:
:
:
:
:
:
:
:
:
:
1 pcs
1 pcs
1 pcs
1 pcs
4 pcs
1 pcs
2 pcs
1 pcs
1 pcs
1 pcs
1 pcs
5.
6.
7.
8.
9.
10.
5
:
:
:
:
:
:
:
:
maximum 2 unit
Quaternary
0,0001-5,0 ml/min or greater
1%
0.1% RSD
5000 - 6000 psi
1%
min 3
Detektor UV-Vis
a. Lamp
b. Wavelength range
c. Wavelength Precision
d. Wavelenght Accuracy
e. Linearity
f. Function
g. Noise
:
:
:
:
:
:
:
:
1 unit
D2 lamp
200 - 600 nm or greater
0,1 nm
1 nm
2,5 AU
Dual Wavelength
: 1 unit
: 4 C to 65 C or higher
:
:
:
:
:
5 x 10-6 AU
1 unit
2% or better
4 C - 40 C
0,1-100ul
min 100 vial @ 1 - 2 ml
Degasser
: 1 unit
Data Processor
: 1 set
- Minimum Core i3 2100, 3.1 GHz, Intel GMA,
Win 7 Pro 32-bit, HDD 500 GB 7200RPMSATA, USB Optical Mouse & Keyboard,
Media Card Reader, Monitor LCD 18,50", Printer.
- Compatible Software for Data analysis and reporting
Include
1 Instalation
2 Training
3 Tool kits (1 set)
4 Maintenance & autorinsing Kit for pump (1 set)
5 Dust Cover
6 C18 coloumn, 5m, 25 cm: minimum 2 pcs
7 Sampel vial min 1 ml (100 pc/pk)
8 Micro Syringe 100 L, minimum 1 pcs
9 Compatible mixer, min 1 set
10 Guarantee min. 1 year
11 Spare Part Availability min. 5 year
12 Reservoir Tray (1 pcs)
13 Original manual book
14 Factory certificate
15 Stabilizer min 3 KVA
16 Needle wash (1 set)
17 HUB W/ Cable
6
Unit
: Quarternary
:
:
:
:
:
:
2. Detektor (1 unit)
a. Lampu
b. Rentang panjang gelombang
c. Presisi Panjang gelombang
d. Akurasi Panjang gelombang
e. Lineritas
f. Photodiodes
:
:
:
:
:
:
: 4 C - 65 C or higher
: 1% atau lebih kecil
4. Autosampler (1 unit)
a. Injection Accuracy
b. Injection Volume range
c. Sampel Capacity
: 2% or better
: 0.1 - 100 l or better
: min 100 Vial @1 - 2 ml
D2 lamp
190-800 nm atau lebih besar
0.1 nm
1 nm
2.5 AU
512
13.
14.
15.
16.
17.
7
SPECTROPHOTOMETER UV-VIS *)
Specifications:
a. Spectral bandwitch
b. Wavelength range
c. Wavelength accuracy
d. Stray light
e. Photometric system
f. Photometric range
Unit
:
:
:
:
1 nm
190 - 1100 nm or better
0.2 nm at 656.1 nm or better
0.05 % or less (220 nm & 340 nm)
g. Photometric accuracy
h. Photometer repeatability
i. Baseline Stability
j. Baseline flatness
k. Light source
: 0.0003 Abs
: 0.0006 abs (200 to 900) or better
: W1 and D2 lamp.
l. Noice level
Included of :
1. Instalation
2. Training
3. Guarantee min.a year
4. Original operation manual
5. Dust Cover
6. Tools kit
7. Glass Filter Holmium Oxide
8. Shutter Block
:
:
:
:
:
9.
10.
11.
12.
13.
14.
Cuvette/cell 1-cm
Stabilizer 1 KVA
Multi-cell sample compartment unit with 6-cell holder
Factory Certificate
Rectangular Quartz Cell, 10 mm
Branded personal computer and printer:
- Minimum suplied : Intel Pentium Core II Duo or similar
: 1 set
: 1unit
: 2 Pcs/set
DISSOLUTION TESTER *)
1. Specifications :
a. Flask temperatur
- Range
- Accuracy
b. Bath capacity
c. Spindle speed
- Range
- Accuracy
d. Vibration
e. Voltage
f. Supporting systems including with
2 Accessories :
a. USP / NF Glass dissolution flask
b. USP all teflon paddle
c. basket assembly, 40 mesh basket
d. sampling probe
e. USP Calibrator Prednisone Tablet
f. Stainless wire to sink capsule
g. Filter
h. Sinker Japanese Pharmacopoeia Cage
Unit
Unit
: 30 to 40 C or better
: 0.2 C or better
: 8 flasks
:
:
:
:
:
:
:
:
:
:
:
:
:
3 Included of :
1. Instalation
2. Training
3. Dust cover
4. Guarantee min. A year
5. original operation manual(plus bahasa indonesia)
9
2. Autosampler
1. Dissolution Tester
Specifications :
a. Flask temperatur
Range
Accuracy
b. Bath capacity
c. Spindle speed
Range
Accuracy
d. Voltage
e. Supporting systems including with
- 8pcs USP/NF glass dissolution flask
- 8 pcs USP paddles
- 8 basket assembly 40 mesh basket
- 8 pcs sampling probe
-USP Calibrator Prednisone (30 tablets)
-Stainless wire to sink capsule 1 roll
-Filter (pack of 100)
: 30 to 40 C or better
: 0.5 C or better
: 8 flasks
: 25 to 250 rpm or better
: 1 rpm or better
: 220 V-240 V, 50/60 Hz
2. Autosampler
Specifications :
Include precision syringe pump sampling
Change and save minimum up to 20 protocols, easy-to-use routines, password protect
Built-in validation, calibration and diagnostics, plus unique advanced features
Teflon valves, media replace and system rinse & wash.
Stainless probes for media replace and waste; 8 sample system
24 hours sampling time (sustained release)
Media replace and system rinse
3 Accessories :
a. Validation tool kit
b. Replacement filters
c. Base-kit, including Device box
d. Sinker Japanese Pharmacopoeia Cage
e. Sample and return probe kit
f. E-prob actuator kit
g. Vessel cover
h. Return Harness,6 ft
i. Evaporation caps for 16 mm test tube
j. Certified calibrated tachometer
k. Certified calibrated thermokopel
: 1 set
: pack of 100
:
:
:
:
:
:
:
:
8 pcs
8 pcs
8 pcs
8 pcs
8 pcs
pack of 50
1 set
1 set
4 Included of :
1. Instalation
2. Training
3. Dust cover
4. Guarantee min. 1 year
5. Spare Part Availability min. 5 year
6. original operation manual (plus bahasa indonesia)
7. Alignment kit
10
MIKROSKOP KAMERA *)
Specifications:
A. Microscope body
a. Lamp
b. Optical system
c. Eyepieces
d. Objective
e. Able to pre -focus & tension adjusment
:
:
:
:
B. Accessories :
a. Compatible Digital Camera
b. PC + Sofware for capturing image and recording movie files,can be
attached to any desktop or laptop
c. Memory
C. Included of
1. Object glass and cover
2. instalation
3. training
4. guarantee min. a year
5. original operation manual (plus bahasa indonesia)
6. dust cover
11
Unit
Unit
halogen illumination
UIS
up to 10x
up to 10x, 40x, 100x
: CompactFlash,microdrive,xD-Picture Card
: min 100 pcs
- Main Body
- Coating
h. Controller
Include of
1. Installation
2. Guarantee min a year
3. Training
4. Original operation manual
5. Sash stop kit and standar accessories for fume hood (blower, ducting, piping, etc)
12
Unit
Type I
Daily Volume
Delivery Flow rate-maximum
Inorganics ( resitivity @ 25C)
Organics/TOC
Bacteria (with Biofilter)
Endotoxin (with Biofilter)
DNAse (with Biofilter)
RNA (with Biofilter)
:
:
:
:
:
:
:
:
min. 10 litre
Up to 2 L/min
18.2 M.cm
< 5 ppb
< 1 cfu/10 ml or better
< 0.001 EU/ml
< 20 pg/ml or better
<0.002 ng/ml
Type II
Daily Volume
Daily output
Inorganics ( resitivity @ 25C)
Organics/TOC
Bacteria
Recirculating
Supply voltage
:
:
:
:
:
:
:
min. 7 litre/hour
170 L /day or better
10 to > 10 M - cm
< 20 ppb
< 1 cfu/10 ml or better
Fully Deionization
100 -240 V ac / 50 -60 Hz
Included of :
1. Tank 25 L with 5 level switches,
2. Deionization Cartrige ( 2 )
3. Purification Pack ( 2 )
4. Biofilter ( 2 )
5. POU filter ( 2 )
6. Warranty 1 year
7. Install
8. Certificate of Conformity
13
DIGITAL BURET
Spesifikasi:
Dispensing range
Display
volume buret
Included
1. safety valve
2. microbatteries 2 piece
3. telescopic aspiration tube
4. bottle adapters minimal 3 piece
5. adjustable discharge tube
6. recirculation tube
7. original operation manual (plus bahasa indonesia)
8. instalation
9. guarantee min. a year
10. training
14
Unit
Unit
: 0.01ml - 999.9 ml
: LCD
: minimal 20 ml
:
16. Training
17. original operation Manual (plus bahasa indonesia)
18. garansi minimal 1 tahun
15
Unit
Unit
Unit
Include of
1. Syringe 50 l & 100 l minimal 10 pcs
2. Syringe 25 l minimal 20 pcs
3. Instal
4. Training
5. original operation Manual (plus bahasa indonesia)
6. garansi minimal 1 tahun
16
AUTOMATIC TITRATOR *)
Spesifications :
a. Application
b. Burette
c. operation
d. Interface
e. max. number of sampel
:
:
:
:
:
Accessories :
a. Magnetic stirer
b. pp beaker set of 500 pcs
c. Glass Beaker 80 ml set of 20 pcs
d. Burettes for 2 titration
e. IQ/OQ
f. Printer
Included of :
1. Installation
2. Training
3. Guarantee min. a year
4. Original operational manual (plus bahasa indonesia)
17
ULTRASONIC BATH
Specifications:
a. Capacity
b. Temperatur range
c. Timer
d. Frequency
e. Display
f. Material
Include of
1. Guarante min. A year
2. Original operation manual (plus bahasa indonesia)
3. Dust cover ( 1 unit)
4. Tray/basket (stainless steel) (1 unit)
5. Hinged Lids made of Stainless Steel to be mounted on the unit
18
:
:
:
:
:
:
:
:
:
:
:
:
10 liters
up to 70 o C or greater
minimum 1-30 minutes or greater
minimum 35 KHz
LED
Stainless steel or equivalent
Unit
Unit
Included of
1. Training
2. Guarantee min.1 year
3. Manual book
4. Certificate of Origin
19
SHAKER
Specifications :
a. Motion
b. Speed
- Speed frequency (min-1)
c. Load capacity
d. Amplitude (mm)
e. Power
f. Timer
: Orbital
:
:
:
:
:
0 to 200 or greater
minimal 8 kg
min 10 mm
115-230 V, 50/60 HZ
Up to 60 min or greater
g. Dimention
h. Shaking platform
Acessories
1. fastening bar 545 mm lengthways minimal 2 unit
2. clamping rolls 375 mm, widhtways minimal 3 unit
3. clamping rolls 375 mm, widhtways minimal 3 unit
Included of
1. Instalation
2. Guarantee min. 1 year
3. Spare part availability min. 5 year
4. Original operation manual
20
21
SEMIMICRO BALANCE *)
Specifications :
a. Capacity max
b. Readability
c. Reapeatability
d. Liniearity
e. Power
f. Display
:
:
:
:
:
:
Acessories
1. Printer
2. Antistatic brush
3. Stainless steel spatulla, 6 x 180 mm @ 5 pcs
4. Stabilizer 500 mA
5. External Calibrator 100 and 200 g E2
Included of
1. Installation
2. Training
3. Original operational manual book
4. Guarantee min 1 year
5. Spare part availability min 1 year
6. Dust cover
CENTRIFUGE
Specifications :
a. Max Speed (rpm)
b. Max capacity
c. Control system
d. Display digital fuse number speed time
Unit
Unit
:
:
:
:
e. Timer
f. Power requirements
: 1-99 minutes
: 220-240; 50-60 Hz
Accessories :
1. - Angle- Rotor
: 6 x 50 ml
Include of :
1. Guarantee min. 1 year
2. Original operation manual (plus Bahasa indonesia)
3. Spare part availability min. 5 year
22
pH Meter Berdiri *)
Specifications :
a. pH Range
b. pH Relative accuracy
c. pH Resolution
d. mV Range
e. mV Relative Accuracy
f. mV Resolution
g. Temperature range
h. Acessories
Included of
1 Installation
2 Training
3 Guarantee min 1 year
4 Original Operation manual (plus bahasa indonesia)
5 Storage solution
6 spare part availability 5 year
7 electrolyte solution
23
:
:
:
:
:
:
:
:
Unit
Unit
: min 350 C
: 6 sample
: 230 V, 50/60Hz
6
7
8
9
10
24
HEATING MANTLE
Specifications :
a. Flask capacity
b. Temperature range
c. Temperature controller
d. Material
:
:
:
:
Unit
Unit
Unit
500 ml
up to 4500C
digital
Nichrome Wire or equivalent
Include of :
1 Guarantee min. 1 year
2 Spare part availability min. 5 year
3 Original operation manual (plus bahasa indonesia)
25
: min 220 g
: 0,0001 g
: 0,1 mg
: 0,2 mg or less
Included of:
1 Printer
2 Instalation
3 Dust cover
4 Guarantee min 1 year
5 Spare part availability min 5 year
6 Original operational manual book
7 Weight Standart Class E2 Capacity 100 & 200 g
26
Included of
1 Instalation
2 Training
3 Heating block
4 Controller
5 Glassware ( 6 pcs)
6 Straight Air Condenser
27
Unit
: 1 unit
: 1 unit
: minimum 100 ml
: 6 samples
: 230V/50/60 Hz
: 12 pcs
: 6 pcs
: 25 pcs
: 0 C to 100 C
: 0.2 C
: 210 x 400 x 500 mm or greater
28
29
:
:
:
:
:
Unit
Unit
: 100-240V, 50-60 Hz
: 20 to 280 rpm or greater
: 20 to 150 0C or wider
: 4 L or greater
: Fix or adjustable
: 220/240 V, AC, 50/60 Hz
: 210 x 400 x 500 mm or greater
E Acessories :
1. vapor temperature sensor
2. condenser
3. Manual vacuum controller
4. Woulff botle minimal 1 pcs
Unit
F Included of :
1 Installation
2 Training
3 Guarantee min 1 year
4 Original Operation Manual (plus bahasa indonesia)
30
MICROWAVE DIGESTION
Spesification :
a. Temperature control
: every vessel
b.
c.
d.
e.
f.
Jumlah vessel
Volume vessel
Vessel material
Temperature
Presisi temperatur
Accessories
1. Turntable with 10 pcs of Vessels 60 mL
- Forming Systems for Vessels 60 mL
- Consumables for Vessels 60 mL For approx 2500 digestions
- Spare of Vessels 60 mL , pk/10
2. Turntable with 24 pcs Quartz Vessels 10 mL
- Forming Tools for Quartz Vessels
- Rupture Disc for Quarts Vessels, pk/5
- Lids for Quartz Vessels, pk/4
- Fixations Plate of Rupture Disc
- Spare of Quartz Vessels 10 mL, pk/24
:
:
:
:
:
min 10 vessel
min 10 ml
PTFE/Teflon
50-2600 C
1C at 200C
Included of
1. instalation
2. training
3. guarantee min. a year
4. original operation manual (plus bahasa indonesia)
31
WATERBATH
Spesifications
a. Capacity
b. Casing, container and cover made of
c. Temperature range
d. Resolution
h. Display
i. Timer
Accessories
a. Flat stainless steel cover with openings& concentric ring sets
b. Gable stainless steel cover mounted for condensate drainage
c. water level control
Included of :
1. Instalation
2. Guarantee min. a year
3. Original operation manual (plus bahasa indonesia)
Unit
:
:
:
:
:
:
14 liter
Stainless steel
10 - 95C or better
0.1C
LED
1 minutes to 99 hours or better
: 6 holes
32
33
34
:
:
:
:
:
:
:
:
:
:
:
:
:
:
:
Unit
Unit
Unit
Unit
up to 425C
230 V
50 - 60 Hz
1800 W
50 - 250 ml
Minimal 6
Min 590 x 220 x 125 or wider
Min 7 kg
min 10 Kva
220 volt (min 1 fase)
45 - 65 Hz
220 volt (min 1 fase)
50 / 60 Hz
up to 120% 0r better
approx 10 minutes
UV CABINET
Specifications :
a. UV lamps in combination with UV viewing box
b. Consist of : UV lamps for 2 wavelength 254/365nm (2 x 6W) or better
Included of :
1. Guarantee min. 1 year
2. Spare part availability min. 5 year
3. Original operation manual (plus bahasa indonesia)
35
c. Speed range
d. Temperature range
e. Power Supply
Included of :
1. Magnetic bar minimal 5 pcs
2. Guarantee min.a year
3. Original operation manual (plus bahasa indonesia)
36
:
:
:
:
:
:
:
Unit
5C
400C 10 %
approx 26.0 x 26.0 cm
220 - 240 V / 6.40 A / 1530 W
Ceramic Top Hot Plate or equivalent
CSA, CE, NRTLc (CCSAUS)
28,7 x 41.1 x 10.1 cm 10 %
37
Unit
38
MUFFLE FURNACE
Specifications :
a. Capacity
b. Temperature range
c. Interior Dim ( W x D x H)
d. Exterior Dim ( W x D x H)
e. Temp Uniformity
f. Temp Stability
g. Power Output
h. Voltage
i. Temperature control
Includes:
1. Warranty
2. Supplied with cord and plug set
Unit
:
:
:
:
:
:
:
:
:
14 L 10 %
up to 1100C
325 x 254 x 172 mm 10 %
485 x 510 x 533 mm 10 %
2.2C at 1000C
0.3C at 1000C
max. 3100 Watts
12.9A / 208-240V
Digital single set point control
: min 24 month
39
40
DISTILLATION UNIT*)
Specifications :
a. Kjeldahl nitrogen and protein distillation unit; Alcohol& phenol distillation;
volatil acids & Cyanide determinations
b. Acid-resistant pump
c. Safety features:
- Protective door
- Sample tube detector
- Service door sensor
- Drip tray
- Cooling water flow sensor
d. Methods can be store
:
e. Tube volume
:
f. Recovery rate
:
g. Reproducibility (RSD)
:
h. Detection limit
:
i. Voltage
:
j. Steam Performance
:
k. Power consumption
:
l. Set of storage tank
:
DISTILLATION UNIT FOR ANALISYS SO2 WITH TITRATOR *)
Specifications :
A. Destillation Unit
a. Aplikasi determination of sulfur dioxida.
Can be used for Kjeldahl nitrogen and protein distillation unit;
Alcohol& phenol distillation; volatil acids & Cyanide determinations ,
b. Acid-resistant pump
c Safety features:
- Protective door
- Sample tube detector
- Service door sensor
- Drip tray
- Cooling water flow sensor
d Methods can be store
e Tube volume
f. Recovery rate
g. Reproducibility (RSD)
h. Detection limit
i. Voltage
j.. Power consumption
k. Set of storage tank
B. Titrator
:
:
:
:
:
:
:
Unit
Unit
9 or more
min 250 ml (1 set)
min. 99.5%
minimum 1%
minimum 0,1 mg
220 V - 240 V, 50/60 Hz
160 ml / 5 min or better
2200 W or less
2 x 20 liter
50 or more
min 250 ml (1 set)
min. 99.5%
1%
minimum 0,1 mg
220 V - 240 V, 50/60 Hz
2200 W or less
4 x 20 liter
41
Unit
Unit
: 1 unit
: 1 unit
: 4 Bar
: 220-240 V/ 50-60 Hz
:
:
:
:
47 mm
Compatible
Glass
1000 ml
Accessories
1. Silicon rubber laboratory tubing, compatible,L= 2 m
2. Support Screen
42
Weighing capacity
Readability
Repeatability
Linearity
Display
Accessories
1. Antivibration Table (1 set)
2. External calibrator 2 and 5 gram E2 (1 set)
3. Printer (1 unit)
4. Filter weighing kit (1 set)
5. Antistatic brush (1 set)
6. Dust Cover (1 set)
:
:
:
:
:
6-7 g
0,001 mg
0,001 mg or better
0,004 mg or better
touchscreen
Include of :
1. Instalation
2. Original operational manual book (plus bahasa indonesia)
3. Guarantee min 1 year
4. Training
43
44
THERMOHYGROMETER DIGITAL
Specifications :
a. Temperature Range
b. Humidity Range
c. Temperature Accuracy
d. Humidity Accuracy
:
:
:
:
Accessories
1. Battery compatible @ 2 pcs
2. With clock
3. accesory for wall mounting (screws or adhesive tape).
Include of
1. Original Operation Manual (plus bahasa indonesia)
2. Guarantee min 6 months
Unit
Unit
Unit
(-5)o to 55 oC or wider
20 -95 % or wider
1C
5 % rF (rh)
Included of :
1. Guarantee min. 1 year
2. original operation manual (plus bahasa indonesia)
45
47
Unit
Unit
k. Trainning
l. Min guarantee 1 year
m. Standar operating prosedur (English and indonesian)
48
Unit
49
VORTEX MIXER
Spesifications
a. speed range up to 3000 rpm
b. used for at least 1.5 ml test tube
c. with analog display and control scale
d. orbit diameter 4 mm
e. speed control with knob for different modes of mixing
f. power supply 230 V/ 50-60 hz
g. min guarantee 1 year
h. standar operating procedure (English and Indonesia)
Unit
50
Unit
Unit
51
SEROLOGI PIPET
Spesifications
a. baterry rechargeable
b. autoclavable
c. used for pipette types 1 ml to 100 ml
d. at least 7 hours operation
e. aspirating speed at least 25 ml in 5 second
f. membrane filter replaceable
g. touch control adjustable speed
:
:
:
:
:
:
:
Include
1.
2.
3.
4.
52
holder
Min guarantee 1 year
Standar operating procedur (English and indonesia)
Comfortable design for operation
Unit
: 1 unit
Spesifications
inc: impact absorbing holster and two 80PK-1 beaded probe thermocouples
a. temperatur range for -250degC to 400degC:
b. Batteries 3 AA
c. Accuracy above -100degC: 0.05% + 0.3degC
d. Min guarantee 1 year
e. Standar operating procedure (English and Indonesia)
53
Unit
54
CABINET STERILIZING
Spesifications
a. with UV lamp
b. dimensions
c. accesories
d. interior decoration of a stainless steel
e. include fall prevention metal fittings
f. Power supply AC 100 V 50/60 Hz
g. Step up & down transformer
h. with timer and analog display for clock
i. number of sheet up to 10
j. 2 doors
k. min guarantee 1 year
l. Operating manual prosedur (english and Indonesian)
m Trainning
Unit
Unit
55
TURBIDIMETRI
Spesifications
Unit
Unit
Included of
1. Min guarantee 1 year
2. Trainning
3. Standar operation procedure (English and Indonesia)
57
COOLED INCUBATOR
Spesifications
a. Volume
b. Temperatur range
c. Interior chamber
d. Over-and undertemperatur protecting with alarm
e. Digital display
f. Works calibration certificate
g. interior dan exterior door
: 25010 liter
: -12C to 60C5C
: Stainless steel
h.
i.
j.
k.
Included of
1. Min guarantee 1 year
2. Trainning
3. Operating manual prosedur (english and indonesian)
58
PCR HOOD
Spesifications
a. with UV lamp and timer
b. HEPA filter H14 or >99.99% at 0.1 to 0.3 microns
c. Internal dimension at least 900 (max 1200) x 500 x 500 mm
d. external dimensions max 1200 x 700 x 1000 mm
e. epoxy powder coated with antimicrobial coating
f. pre filter
g. air flow velocity average 0.3 m/s (60 fpm)
h. power supply 220-230 v/ 50-60 hz
Unit
Unit
Included of
1. Min guarantee 1 year
2. Trainning
3. Operating manual prosedur (english and indonesian)
59
STERITEST PUMP *)
Spesifications
a. pump with bottle holder and canister holder
b. autoclavable
c. power supply 230 V/ 50-60 Hz
d. Materials of Construction
Frame, pump head, Pump head
cover, and bottle holder
keypad and screen window:
Drain Tray
Drain Tray tubing
e. Dimensions
f.
Included of
1. consumable and accesories
Ampoule breaker for sterility test
(1 pk)
: pump: approx. 35 x 30 x 25 cm
: pump with bottle handle, canister handle approx. 59 x 34 x 53 cm
Canister with membran for sterility test for liquids in ampoules or collapsible bags (2 pk)
Canister with membran for sterility test for antibiotic, 10 / pack (2 pk)
Canister with membran for sterility test for solvent, creams, ointment (2pk)
veterinary injectables, 10 / pack
2. Min guarantee 1 year
3. Trainning
4. Standar operation operation (English and Indonesia)
60
INKUBATOR KERING
Spesifications
a. compatible with thermo block for at least 20 x 1.5ml, 20 x 2 ml, 8 x 15ml, 4 x 50ml test tubes
b. temperatur setting at least 4degC to 99degC
c. temperatur range at least 30degC to 99degC
d. digital timer at least 1 min to 90 hours
e. incubating accuracy at least 1.0degC
f. heating speed at least 5degC/min
g. cooling speed at least 5degC/min between 99degC and 25degC
h. power supply 220-230V/50-60 hz
Unit
Unit
Included of
1. min guarantee 1 year
2. trainning
3. standar operation precedur (English and Indonesia)
Assesories
1. thermoblock for test tube 1,5ml
2. thermoblock for test tube 2ml
3. thermoblock for test tube 15ml
4. thermoblock for test tube 50ml
5. box for all tube types, interior dimensions at least 13 x 8 x 5 cm
61
MICROCENTRIFUGE
Spesifications
a. speed
b. max capacity
c. timer
d. dimension
e. refrigerated
f. temperatur control
g. power supply 230 v/ 50-60 Hz
h. LCD display
Included of
1. rotor for 1.5/2ml, 15ml, 50ml, microplate rotor
2. Trainning
3. Min guarantee 1 year
4. Operating manual prosedur (English and Indonesia)
62
Unit
Unit
Unit
Unit
Unit
Unit
Unit
1
2
1
1
1
1
1
MEREK / TYPE